Abstract
The network architecture on the Flex System™ platform has been specifically designed to address network challenges, giving you a very scalable way to integrate, optimize and automate your data center. The Flex System FC5022 2-port 16Gb FC Adapter enables high-speed access for compute nodes to an external storage area network (SAN). This adapter is based on Brocade architecture, and offers end-to-end 16 Gb connectivity to SAN. It can auto-negotiate, and also work at 8 Gb and 4 Gb speeds. It has enhanced features like N_Port trunking and N_Port ID Virtualization (NPIV) as well as boot-from-the-SAN with automatic LUN discovery and end-to-end Server Application Optimization (SAO).
Note: This adapter has been withdrawn from marketing
Introduction
The network architecture on the Flex System™ platform has been specifically designed to address network challenges, giving you a very scalable way to integrate, optimize and automate your data center. The Flex System FC5022 2-port 16Gb FC Adapter enables high-speed access for compute nodes to an external storage area network (SAN). This adapter is based on Brocade architecture, and offers end-to-end 16 Gb connectivity to SAN. It can auto-negotiate, and also work at 8 Gb and 4 Gb speeds. It has enhanced features like N_Port trunking and N_Port ID Virtualization (NPIV) as well as boot-from-the-SAN with automatic LUN discovery and end-to-end Server Application Optimization (SAO).
Figure 1 shows the Flex System FC5022 2-port 16Gb FC Adapter.
Figure 1. Flex System FC5022 2-port 16Gb FC Adapter
Did you know?
The FC5022 adapter is designed to work best with the Flex System FC5022 16Gb SAN Scalable Switch and together, these deliver considerable value by simplifying the deployment of server and SAN resources, reducing infrastructure and operational costs, and maximizing server and SAN reliability, availability, and resiliency.
Even with an 8 Gb Fibre Channel SAN fabric, having 16 Gb adapters and switches in the Flex System means that you can eliminate any oversubscription from the SAN fabric to maximize application throughput. Having 16 Gb adapters and switches also offers future investment protection by enabling the density of virtual machines (VMs) to be increased on a compute node and by providing performance head room to support demanding solid-state drive storage technologies.
Part number information
Table 1 shows the part number to order this card.
Table 1. Part number and feature code for ordering
Description | Part number | Feature code (x-config) |
Flex System FC5022 2-port 16Gb FC Adapter | 88Y6370 | A1BP |
The part number includes the following items:
- One Flex System FC5022 2-port 16Gb FC Adapter
- A documentation CD containing the adapter user’s guide
- The Important Notices document
Features
The Flex System FC5022 2-port 16Gb FC Adapter has the following features:
- 16 Gbps Fibre Channel
- Utilize 16 Gbps bandwidth to eliminate internal oversubscription
- Investment protection with the latest Fibre Channel technologies
- Reduce the number of ISL external switch ports, optics, cables and power
- Over 500,000 IOPS per port -- maximizes transaction performance and density of VMs per compute node
- Achieves performance of 330,000 IOPS for email exchange and 205,000 IOPS for SQL Database
- Boot from SAN allows the automation SAN Boot LUN discovery to simplify boot from SAN and reduce image management complexity
- Brocade Server Application Optimization (SAO) provides Quality of Service (QoS) levels assignable to VM applications
- Direct I/O enables native (direct) I/O performance by allowing VMs to bypass the hypervisor and communicate directly with the adapter
- Brocade Network Advisor simplifies and unifies the management of Brocade adapter, SAN, and LAN resources through a single pane-of-glass
- LUN Masking, an Initiator-based LUN masking for storage traffic isolation
- N_Port Id Virtualization (NPIV) allows multiple host initiator N_Ports to share a single physical N_Port, dramatically reducing SAN hardware requirements
- Target Rate Limiting (TRL) throttles data traffic when accessing slower speed storage targets to avoid back pressure problems
- Unified driver across all Brocade-based Lenovo adapter products with automated version synchronization capability
- RoHS-6 compliant
Supported servers
The following table lists the Flex System compute nodes that support the FC5022 2-port 16Gb FC Adapter.
Table 2. Supported servers
Description | Part number | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Flex System FC5022 2-port 16Gb FC Adapter | 88Y6370 | Y | N | Y | Y | N | Y | Y |
N
|
Y | Y |
See the ServerProven® website for the latest information about the expansion cards that are supported by each blade server type:
http://www.lenovo.com/us/en/serverproven/flexsystem.shtml
I/O adapter cards are installed in the slot in supported servers, such as the x240, as highlighted in the following figure.
Figure 2. Location of the I/O adapter slots in the Flex System x240 Compute Node
Supported I/O modules
The FC5022 2-port 16Gb FC Adapter supports the I/O modules listed in the following table. One or two compatible switches must be installed in the corresponding I/O bays in the chassis. Installing two switches means that both ports of the adapter are enabled.
Description | Part number | Support the FC5022 adapter |
Flex System FC3171 8Gb SAN Switch | 69Y1930 | No |
Flex System FC3171 8Gb SAN Pass-thru | 69Y1934 | No |
Flex System FC5022 16Gb SAN Scalable Switch | 88Y6374 | Yes |
Flex System FC5022 24-port 16Gb SAN Scalable Switch | 00Y3324 | Yes |
Flex System FC5022 24-port 16Gb ESB SAN Scalable Switch | 90Y9356 | Yes |
The following table shows the connections between adapters installed in the compute nodes and the switch bays in the chassis.
Table 4. Adapter to I/O bay correspondence
I/O adapter slot in the server | Port on the adapter | Corresponding I/O module bay in the chassis |
Slot 1 | Port 1 | Module bay 1 |
Port 2 | Module bay 2 | |
Slot 2 | Port 1 | Module bay 3 |
Port 2 | Module bay 4 |
The connections between the adapters installed in the compute nodes and the switch bays in the chassis are shown diagrammatically in the following figure.
Figure 3. Logical layout of the interconnects between I/O adapters and I/O modules
Supported operating systems
The FC5022 2-port 16Gb FC Adapter supports the following 64-bit operating systems:
- Microsoft Windows Server 2008 R2
- Microsoft Windows Server 2008, Datacenter x64 Edition
- Microsoft Windows Server 2008, Enterprise x64 Edition
- Microsoft Windows Server 2008, Standard x64 Edition
- Microsoft Windows Server 2008, Web x64 Edition
- Microsoft Windows Server 2012
- Microsoft Windows Server 2012 R2
- Red Hat Enterprise Linux 5 Server with Xen x64 Edition
- Red Hat Enterprise Linux 5 Server x64 Edition
- Red Hat Enterprise Linux 6 Server x64 Edition
- Red Hat Enterprise Linux 7
- SUSE LINUX Enterprise Server 10 for AMD64/EM64T
- SUSE LINUX Enterprise Server 10 with Xen for AMD64/EM64T
- SUSE LINUX Enterprise Server 11 for AMD64/EM64T
- SUSE LINUX Enterprise Server 11 with Xen for AMD64/EM64T
- VMware ESX 4.1
- VMware ESXi 4.1
- VMware vSphere 5.0 (ESXi)
- VMware vSphere 5.1 (ESXi)
- VMware vSphere 5.5 (ESXi)
See the OS Interoperability Guide for the latest information about the specific versions and service packs that are supported: http://lenovopress.com/osig
Regulatory compliance
The adapter conforms to the following standards:
- United States FCC 47 CFR Part 15, Subpart B, ANSI C63.4 (2003), Class A
- United States UL 60950-1, Second Edition
- IEC/EN 60950-1, Second Edition
- FCC - Verified to comply with Part 15 of the FCC Rules, Class A
- Canada ICES-003, issue 4, Class A
- UL/IEC 60950-1
- CSA C22.2 No. 60950-1-03
- Japan VCCI, Class A
- Australia/New Zealand AS/NZS CISPR 22:2006, Class A
- IEC 60950-1(CB Certificate and CB Test Report)
- Taiwan BSMI CNS13438, Class A
- Korea KN22, Class A; KN24
- Russia/GOST ME01, IEC-60950-1, GOST R 51318.22-99, GOST R 51318.24-99, GOST R 51317.3.2-2006, GOST R 51317.3.3-99
- IEC 60950-1 (CB Certificate and CB Test Report)
- CE Mark (EN55022 Class A, EN60950-1, EN55024, EN61000-3-2, EN61000-3-3)
- CISPR 22, Class A
Physical specifications
The dimensions and weight of the adapter are as follows:
- Width: 100 mm (3.9 in.)
- Depth: 80 mm (3.1 in.)
- Weight: 13 g (0.3 lb)
Shipping dimensions and weight (approximate):
- Height: 58 mm (2.3 in.)
- Width: 229 mm (9.0 in.)
- Depth: 208 mm (8.2 in.)
- Weight: 0.4 kg (0.89 lb)
Popular configurations
The FC5022 2-port 16Gb FC Adapter can be used in various configurations. The following figure shows the I/O installed in an I/O adapter slot 2 of the x240, which in turn is installed in the chassis. The chassis is connected to an IBM V7000. The RAID functionality is provided by the external storage system.
Figure 4. Example configuration
The following table lists the parts that are used in the configuration.
Table 5. Components used when connecting the FC5022 2-port 16Gb FC Adapter to external disk storage
Part number/machine type | Description | Quantity |
8737 | Flex System x240 Compute Node or other supported server | 1 to 14 |
88Y6370 | FC5022 2-port 16Gb FC Adapter | 1 per server |
8721-A1x | Flex System Enterprise Chassis | 1 |
90Y9356 | Flex System FC5022 24-port 16Gb ESB SAN Scalable Switch | 1 or 2 |
88Y6393 | Brocade 16Gb SFP+ Optical Transceiver | 1 per FC cable |
39M5698 | 1m LC-LC Fiber Channel Cable | 1 for each V7000 connection |
2076-124 | System Storage V7000 | 1 |
This configuration also requires additional V7000 features, such as drives and software licenses. These are not listed in the table.
Related product families
Product families related to this document are the following:
Trademarks
Lenovo and the Lenovo logo are trademarks or registered trademarks of Lenovo in the United States, other countries, or both. A current list of Lenovo trademarks is available on the Web at https://www.lenovo.com/us/en/legal/copytrade/.
The following terms are trademarks of Lenovo in the United States, other countries, or both:
Lenovo®
ServerProven®
System x®
The following terms are trademarks of other companies:
Linux® is the trademark of Linus Torvalds in the U.S. and other countries.
Microsoft®, Windows Server®, and Windows® are trademarks of Microsoft Corporation in the United States, other countries, or both.
Other company, product, or service names may be trademarks or service marks of others.