ThinkSystem and ThinkEdge Rail Kit Reference

Comparison Reference

Author
Updated
25 Sep 2024

This document lists the supported rail kits for Lenovo ThinkSystem, ThinkAgile, and ThinkEdge servers and allows you to compare the specifications.

How to search

The web page initially displays all available rail kits. Scroll horizontally to view all the controllers. You can also use the search or filter functions to further narrow the results.

To search: Enter a search term and click Search, or click Add Filter to perform more advanced searching. For information on how to view, rearrange and export the data, click the Help link.

 

Notes

  1. There are no CMA mounting brackets preinstalled on the rail. The CMA mounting brackets are contained in the CMA option kit package. Before installing the CMA, you need to install the CMA mounting brackets first. For detailed instructions, refer to the documentation that comes with the CMA option kit.
  2. If you want to install the rails and a 0U PDU into the same rack, the rack must meet the height and depth requirements. See the sections below for details, Rack cabinets with parallel 0U PDUs and Rack cabinets with perpendicular 0U PDUs.
  3. For best performance, it is recommended that you install the rails to the racks with a 719-mm distance (28.31-inch, Lenovo rack default distance) between the front and rear mounting flanges.
  4. The rail length refers to the distance measured when the rail is not extended.

Rack cabinets with parallel 0U PDUs

The table below lists the rail kits that are supported in each rack cabinet when 0U PDUs are installed in an orientation that is parallel to the sidewalls of the cabinet (sockets facing the rear of the rack). The table also lists the horizontal clearances A and B, as shown in the figure.


Figure 1. Rack cabinets with parallel 0U PDUs

Table 1. Rail kit support
Rack MT Rack depth Rail selection A 1 B 2
9307 1000 mm
(39.37 inches)

Supporting CMA and PDU installation:

  • None
746.65 mm
(29.39 inches)
-23.50 mm 3
(-0.92 inches)

Supporting PDU installation only:

  • 4M17A07273, ThinkSystem Toolless Friction Rail
  • 7M27A05702, ThinkSystem Toolless Slide Rail
  • 7XH7A05901, ThinkSystem ST550 4U Tower to Rack Conversion Kit
  • 4M17A11754, ThinkSystem Toolless Slide Rail Kit v2
  • 4M17A11755, ThinkSystem Toolless Slide Rail Kit v2 Enhanced
  • 4M17A11683, 1U and 2U Slide Rail
  • 4XF7A81940, ThinkEdge 1000mm Friction Rail Kit
  • 4XF7A90718, ThinkEdge 1000mm Friction Rail Kit v2
  • 4M17A69408, ThinkSystem SR670 V2/ SR675 V3 Toolless Slide Rail
  • C3KA, ThinkSystem SR670 V2/SR675 V3 Heavy Systems Toolless Slide Rail Kit
  • 4XF7A99129, ThinkSystem Toolless Stab-in Slide Rail Kit V3
9308 1100 mm
(43.31 inches)

Supporting CMA and PDU installation:

  • 4M17A07280, ThinkSystem Screw-in Slide Rail Kit with 2U CMA
  • 4M17A07281, ThinkSystem Screw-in Slide Rail Kit with 1U CMA
  • 7M27A05700, ThinkSystem Toolless Slide Rail Kit with 2U CMA
  • 7M27A05701, ThinkSystem Toolless Slide Rail Kit with 1U CMA
  • 4M17A11756, ThinkSystem Toolless Slide Rail Kit v2 with 2U CMA
  • 4M17A11757, ThinkSystem Toolless Slide Rail Kit v2 Enhanced with 2U CMA
  • 4M17A11758, ThinkSystem Toolless Slide Rail Kit v2 with 1U CMA
  • 4M17A11683, 1U and 2U Slide Rail
  • 4XF7A97373, ThinkSystem Toolless Slide Rail Kit V4 with 1U CMA
  • 4XF7A97375, ThinkSystem Advanced Toolless Slide Rail Kit V4 with 1U CMA
  • 4XF7A99130, ThinkSystem Toolless Stab-in Slide Rail Kit V3 with 1U CMA
  • 4XF7A99131, ThinkSystem Toolless Stab-in Slide Rail Kit V3 with 2U CMA
772.50 mm
(30.41 inches)
8 mm
(0.31 inches)

Supporting PDU installation only:

  • 4M17A07273, ThinkSystem Toolless Friction Rail
  • 4M17A07274, ThinkSystem Screw-in Slide Rail
  • 7M27A05702, ThinkSystem Toolless Slide Rail
  • 7XH7A05901, ThinkSystem ST550 4U Tower to Rack Conversion Kit
  • 4M17A11754, ThinkSystem Toolless Slide Rail Kit v2
  • 4M17A11755, ThinkSystem Toolless Slide Rail Kit v2 Enhanced
  • 4XF7A97370, ThinkSystem Toolless Slide Rail Kit V4
  • 4XF7A97379, ThinkSystem Toolless Friction Rail V4
  • 4XF7A97371, ThinkSystem Advanced Toolless Slide Rail Kit V4
  • 4XF7A99129, ThinkSystem Toolless Stab-in Slide Rail Kit V3
9363 1100 mm
(43.31 inches)

Supporting CMA and PDU installation:

  • 4M17A07280, ThinkSystem Screw-in Slide Rail Kit with 2U CMA
  • 4M17A07281, ThinkSystem Screw-in Slide Rail Kit with 1U CMA
  • 7M27A05700, ThinkSystem Toolless Slide Rail Kit with 2U CMA
  • 7M27A05701, ThinkSystem Toolless Slide Rail Kit with 1U CMA
  • 4M17A11756, ThinkSystem Toolless Slide Rail Kit v2 with 2U CMA
  • 4M17A11757, ThinkSystem Toolless Slide Rail Kit v2 Enhanced with 2U CMA
  • 4M17A11758, ThinkSystem Toolless Slide Rail Kit v2 with 1U CMA
  • 4XF7A86615, ThinkSystem SR850 V3 Slide Rail
  • 4XF7A86616, ThinkSystem SR860 V3 Slide Rail
  • 4M17A11683, 1U and 2U Slide Rail
  • 4XF7A97373, ThinkSystem Toolless Slide Rail Kit V4 with 1U CMA
  • 4XF7A97375, ThinkSystem Advanced Toolless Slide Rail Kit V4 with 1U CMA
  • 4XF7A99130, ThinkSystem Toolless Stab-in Slide Rail Kit V3 with 1U CMA
  • 4XF7A99131, ThinkSystem Toolless Stab-in Slide Rail Kit V3 with 2U CMA
787.50 mm
(31 inches)
11 mm
(0.43 inches)

Supporting PDU installation only:

  • 4M17A07273, ThinkSystem Toolless Friction Rail
  • 4M17A07274, ThinkSystem Screw-in Slide Rail
  • 7M27A05702, ThinkSystem Toolless Slide Rail
  • 7XH7A05901, ThinkSystem ST550 4U Tower to Rack Conversion Kit
  • 4M17A11754, ThinkSystem Toolless Slide Rail Kit v2
  • 4M17A11755, ThinkSystem Toolless Slide Rail Kit v2 Enhanced
  • 4XF7A81940, ThinkEdge 1000mm Friction Rail Kit
  • 4XF7A90718, ThinkEdge 1000mm Friction Rail Kit v2
  • 4M17A69408, ThinkSystem SR670 V2/ SR675 V3 Toolless Slide Rail
  • C3KA, ThinkSystem SR670 V2/SR675 V3 Heavy Systems Toolless Slide Rail Kit
  • 4XF7A97370, ThinkSystem Toolless Slide Rail Kit V4
  • 4XF7A97379, ThinkSystem Toolless Friction Rail V4
  • 4XF7A97371, ThinkSystem Advanced Toolless Slide Rail Kit V4
  • 4XF7A99129, ThinkSystem Toolless Stab-in Slide Rail Kit V3
9360
9361
1200 mm
(47.24 inches)

Supporting CMA and PDU installation:

  • 4M17A07280, ThinkSystem Screw-in Slide Rail Kit with 2U CMA
  • 4M17A07281, ThinkSystem Screw-in Slide Rail Kit with 1U CMA
  • 7M27A05700, ThinkSystem Toolless Slide Rail Kit with 2U CMA
  • 7M27A05701, ThinkSystem Toolless Slide Rail Kit with 1U CMA
  • 4M17A11756, ThinkSystem Toolless Slide Rail Kit v2 with 2U CMA
  • 4M17A11757, ThinkSystem Toolless Slide Rail Kit v2 Enhanced with 2U CMA
  • 4M17A11758, ThinkSystem Toolless Slide Rail Kit v2 with 1U CMA
  • 4M17A11683, 1U and 2U Slide Rail
  • 4XF7A97373, ThinkSystem Toolless Slide Rail Kit V4 with 1U CMA
  • 4XF7A97375, ThinkSystem Advanced Toolless Slide Rail Kit V4 with 1U CMA
  • 4XF7A99130, ThinkSystem Toolless Stab-in Slide Rail Kit V3 with 1U CMA
  • 4XF7A99131, ThinkSystem Toolless Stab-in Slide Rail Kit V3 with 2U CMA
889.5 mm
(35.02 inches)
-6 mm 3
(-0.24 inches)
Supporting PDU installation only:
  • 4M17A07273, ThinkSystem Toolless Friction Rail
  • 4M17A07274, ThinkSystem Screw-in Slide Rail
  • 7M27A05702, ThinkSystem Toolless Slide Rail
  • 7XH7A05901, ThinkSystem ST550 4U Tower to Rack Conversion Kit
  • 4M17A11754, ThinkSystem Toolless Slide Rail Kit v2
  • 4M17A11755, ThinkSystem Toolless Slide Rail Kit v2 Enhanced
  • 4M17A69408, ThinkSystem SR670 V2/ SR675 V3 Toolless Slide Rail
  • C3KA, ThinkSystem SR670 V2/SR675 V3 Heavy Systems Toolless Slide Rail Kit
  • 4XF7A97370, ThinkSystem Toolless Slide Rail Kit V4
  • 4XF7A97379, ThinkSystem Toolless Friction Rail V4
  • 4XF7A97371, ThinkSystem Advanced Toolless Slide Rail Kit V4
  • C2P8, ThinkSystem SR780a V3 Rail Kit
  • 4XF7A99129, ThinkSystem Toolless Stab-in Slide Rail Kit V3
7D6D
7D6E
1200 mm
(47.24 inches)

Supporting CMA and PDU installation:

  • 4M17A07280, ThinkSystem Screw-in Slide Rail Kit with 2U CMA
  • 4M17A07281, ThinkSystem Screw-in Slide Rail Kit with 1U CMA
  • 7M27A05700, ThinkSystem Toolless Slide Rail Kit with 2U CMA
  • 7M27A05701, ThinkSystem Toolless Slide Rail Kit with 1U CMA
  • 4M17A11756, ThinkSystem Toolless Slide Rail Kit v2 with 2U CMA
  • 4M17A11757, ThinkSystem Toolless Slide Rail Kit v2 Enhanced with 2U CMA
  • 4M17A11758, ThinkSystem Toolless Slide Rail Kit v2 with 1U CMA
  • 4XF7A86615, ThinkSystem SR850 V3 Slide Rail
  • 4XF7A86616, ThinkSystem SR860 V3 Slide Rail
  • 4M17A11683, 1U and 2U Slide Rail
  • 4XF7A89443, ThinkSystem Toolless Slide Rail Kit v2 Enhanced with 1U CMA
  • 4XF7A97373, ThinkSystem Toolless Slide Rail Kit V4 with 1U CMA
  • 4XF7A97375, ThinkSystem Advanced Toolless Slide Rail Kit V4 with 1U CMA
  • 4XF7A99130, ThinkSystem Toolless Stab-in Slide Rail Kit V3 with 1U CMA
  • 4XF7A99131, ThinkSystem Toolless Stab-in Slide Rail Kit V3 with 2U CMA
885 mm
(34.84 inches)
7.91 mm
(0.31 inches)

Supporting PDU installation only:

  • 4M17A07273, ThinkSystem Toolless Friction Rail
  • 4M17A07274, ThinkSystem Screw-in Slide Rail
  • 7M27A05702, ThinkSystem Toolless Slide Rail
  • 7XH7A05901, ThinkSystem ST550 4U Tower to Rack Conversion Kit
  • 4M17A11754, ThinkSystem Toolless Slide Rail Kit v2
  • 4M17A11755, ThinkSystem Toolless Slide Rail Kit v2 Enhanced
  • 4M17A69408, ThinkSystem SR670 V2/ SR675 V3 Toolless Slide Rail
  • C3KA, ThinkSystem SR670 V2/SR675 V3 Heavy Systems Toolless Slide Rail Kit
  • 4XF7A97370, ThinkSystem Toolless Slide Rail Kit V4
  • 4XF7A97379, ThinkSystem Toolless Friction Rail V4
  • 4XF7A97371, ThinkSystem Advanced Toolless Slide Rail Kit V4
  • C2P8, ThinkSystem SR780a V3 Rail Kit
  • 4XF7A99129, ThinkSystem Toolless Stab-in Slide Rail Kit V3

Notes:

  • 1Item A refers to the recommended distance between the front surface of the front mounting flange and the front surface of the parallel 0U PDU.
  • 2 Item B refers to the distance between the left (right) side of the CMA and the right (left) side of the parallel 0U PDU.
  • 3 The negative distance indicates that the CMA and the parallel 0U PDU have an overlap.

Rack cabinets with perpendicular 0U PDUs

The table below lists the rail kits that are supported in each rack cabinet when 0U PDUs are installed in an orientation that is perpendicular to the sidewalls of the cabinet (sockets facing the center of the rack). The table also lists the horizontal clearances A and B, as shown in the figure.


Figure 2. Rack cabinets with perpendicular 0U PDUs

Table 2. Rail kit support
Rack MT Rack depth Rail selection A *
9307 1000 mm
(39.37 inches)

Supporting CMA and PDU installation:

  • None
808.65 mm
(31.84 inches)

Supporting PDU installation only:

  • 4M17A07273, ThinkSystem Toolless Friction Rail
  • 7M27A05702, ThinkSystem Toolless Slide Rail
  • 7XH7A05901, ThinkSystem ST550 4U Tower to Rack Conversion Kit
  • 4M17A11754, ThinkSystem Toolless Slide Rail Kit v2
  • 4M17A11755, ThinkSystem Toolless Slide Rail Kit v2 Enhanced
  • 4M17A11683, 1U and 2U Slide Rail
  • 4XF7A81940, ThinkEdge 1000mm Friction Rail Kit
  • 4XF7A90718, ThinkEdge 1000mm Friction Rail Kit v2
  • 4M17A69408, ThinkSystem SR670 V2/ SR675 V3 Toolless Slide Rail
  • 4XF7A97370, ThinkSystem Toolless Slide Rail Kit V4
  • 4XF7A97379, ThinkSystem Toolless Friction Rail V4
  • 4XF7A97371, ThinkSystem Advanced Toolless Slide Rail Kit V4
  • 4XF7A99129, ThinkSystem Toolless Stab-in Slide Rail Kit V3
9308 1100 mm
(43.31 inches)

Supporting CMA and PDU installation:

  • None
850.05 mm
(33.47 inches)

Supporting PDU installation only:

  • 4M17A07273, ThinkSystem Toolless Friction Rail
  • 7M27A05702, ThinkSystem Toolless Slide Rail
  • 7XH7A05901, ThinkSystem ST550 4U Tower to Rack Conversion Kit
  • 4M17A11754, ThinkSystem Toolless Slide Rail Kit v2
  • 4M17A11755, ThinkSystem Toolless Slide Rail Kit v2 Enhanced
  • 4M17A11683, 1U and 2U Slide Rail
  • 4XF7A97370, ThinkSystem Toolless Slide Rail Kit V4
  • 4XF7A97379, ThinkSystem Toolless Friction Rail V4
  • 4XF7A97371, ThinkSystem Advanced Toolless Slide Rail Kit V4
  • 4XF7A99129, ThinkSystem Toolless Stab-in Slide Rail Kit V3
9363 1100 mm
(43.31 inches)

Supporting CMA and PDU installation:

  • None
871.67 mm
(34.32 inches)

Supporting PDU installation only:

  • 4M17A07273, ThinkSystem Toolless Friction Rail
  • 7M27A05702, ThinkSystem Toolless Slide Rail
  • 7XH7A05901, ThinkSystem ST550 4U Tower to Rack Conversion Kit
  • 4M17A11754, ThinkSystem Toolless Slide Rail Kit v2
  • 4M17A11755, ThinkSystem Toolless Slide Rail Kit v2 Enhanced
  • 4M17A11683, 1U and 2U Slide Rail
  • 4XF7A81940, ThinkEdge 1000mm Friction Rail Kit
  • 4XF7A90718, ThinkEdge 1000mm Friction Rail Kit v2
  • 4M17A69408, ThinkSystem SR670 V2/ SR675 V3 Toolless Slide Rail
  • 4XF7A97370, ThinkSystem Toolless Slide Rail Kit V4
  • 4XF7A97379, ThinkSystem Toolless Friction Rail V4
  • 4XF7A97371, ThinkSystem Advanced Toolless Slide Rail Kit V4
  • 4XF7A99129, ThinkSystem Toolless Stab-in Slide Rail Kit V3
9360
9361
1200 mm
(47.24 inches)

Supporting CMA and PDU installation:

  • 4M17A07280, ThinkSystem Screw-in Slide Rail Kit with 2U CMA
  • 4M17A07281, ThinkSystem Screw-in Slide Rail Kit with 1U CMA
  • 7M27A05700, ThinkSystem Toolless Slide Rail Kit with 2U CMA
  • 7M27A05701, ThinkSystem Toolless Slide Rail Kit with 1U CMA
  • 4M17A11756, ThinkSystem Toolless Slide Rail Kit v2 with 2U CMA
  • 4M17A11757, ThinkSystem Toolless Slide Rail Kit v2 Enhanced with 2U CMA
  • 4M17A11758, ThinkSystem Toolless Slide Rail Kit v2 with 1U CMA
  • 4M17A11683, 1U and 2U Slide Rail
  • 4XF7A89443, ThinkSystem Toolless Slide Rail Kit v2 Enhanced with 1U CMA
  • 4XF7A97373, ThinkSystem Toolless Slide Rail Kit V4 with 1U CMA
  • 4XF7A97375, ThinkSystem Advanced Toolless Slide Rail Kit V4 with 1U CMA
  • 4XF7A99130, ThinkSystem Toolless Stab-in Slide Rail Kit V3 with 1U CMA
  • 4XF7A99131, ThinkSystem Toolless Stab-in Slide Rail Kit V3 with 2U CMA
992.5 mm
(39.07 inches)

Supporting PDU installation only:

  • 4M17A07273, ThinkSystem Toolless Friction Rail
  • 4M17A07274, ThinkSystem Screw-in Slide Rail
  • 7M27A05702, ThinkSystem Toolless Slide Rail
  • 7XH7A05901, ThinkSystem ST550 4U Tower to Rack Conversion Kit
  • 4M17A11754, ThinkSystem Toolless Slide Rail Kit v2
  • 4M17A11755, ThinkSystem Toolless Slide Rail Kit v2 Enhanced
  • 4M17A69408, ThinkSystem SR670 V2/ SR675 V3 Toolless Slide Rail
  • C3KA, ThinkSystem SR670 V2/SR675 V3 Heavy Systems Toolless Slide Rail Kit
  • 4XF7A97370, ThinkSystem Toolless Slide Rail Kit V4
  • 4XF7A97379, ThinkSystem Toolless Friction Rail V4
  • 4XF7A97371, ThinkSystem Advanced Toolless Slide Rail Kit V4
  • 4XF7A99129, ThinkSystem Toolless Stab-in Slide Rail Kit V3
7D6D
7D6E
1200 mm
(47.24 inches)

Supporting CMA and PDU installation:

  • 4XF7A89443, ThinkSystem Toolless Slide Rail Kit v2 Enhanced with 1U CMA
  • 4XF7A97373, ThinkSystem Toolless Slide Rail Kit V4 with 1U CMA
  • 4XF7A97375, ThinkSystem Advanced Toolless Slide Rail Kit V4 with 1U CMA
  • 4XF7A99130, ThinkSystem Toolless Stab-in Slide Rail Kit V3 with 1U CMA
  • 4XF7A99131, ThinkSystem Toolless Stab-in Slide Rail Kit V3 with 2U CMA
969.1 mm
(38.15 inches)

Supporting PDU installation only:

  • 4M17A07273, ThinkSystem Toolless Friction Rail
  • 7M27A05702, ThinkSystem Toolless Slide Rail
  • 7XH7A05901, ThinkSystem ST550 4U Tower to Rack Conversion Kit
  • 4M17A11754, ThinkSystem Toolless Slide Rail Kit v2
  • 4M17A11755, ThinkSystem Toolless Slide Rail Kit v2 Enhanced
  • 4M17A11683, 1U and 2U Slide Rail
  • 4M17A69408, ThinkSystem SR670 V2/ SR675 V3 Toolless Slide Rail
  • C3KA, ThinkSystem SR670 V2/SR675 V3 Heavy Systems Toolless Slide Rail Kit
  • 4XF7A97370, ThinkSystem Toolless Slide Rail Kit V4
  • 4XF7A97379, ThinkSystem Toolless Friction Rail V4
  • 4XF7A97371, ThinkSystem Advanced Toolless Slide Rail Kit V4
  • 4XF7A99129, ThinkSystem Toolless Stab-in Slide Rail Kit V3

Note: * Item A refers to the recommended distance between the front surface of the front mounting flange and the side of the vertical 0U PDU.