Author
Updated
9 Sep 2024Form Number
LP1358PDF size
30 pages, 590 KB- Physical specifications
- Operating environment
- Warranty upgrades and post-warranty support
- Services
- Lenovo TruScale
- Regulatory compliance
- Interoperability
- External storage systems
- External backup units
- Rack cabinets
- Power distribution units
- Uninterruptible power supply units
- Seller training courses
- Related publications and links
- Related product families
- Trademarks
Abstract
The Lenovo ThinkSystem DB720S Gen 7 FC SAN Switch, with its unmatched 64Gbps performance and industry-leading port density, provides a building block that supports data growth, demanding workloads, and data-center consolidation. With a 50% latency reduction compared to the previous generation, the DB720S Switch enables the maximum performance of NVMe storage.
This product guide provides essential pre-sales information to understand the ThinkSystem DB720S FC SAN Switch, its key features and specifications, components and options, and configuration guidelines. This guide is intended for technical specialists, sales specialists, sales engineers, IT architects, and other IT professionals who want to learn more about the switch and consider its use in IT solutions.
Change History
Changes in the September 9, 2024 update:
- Updated a typographical error under Transceivers and cables section:
- Brocade Secure 64-Gb SWL SFP-DD Transceiver, 4M27A65427
- Brocade Secure 64-Gb SWL SFP-DD Transceiver 8-pack, 4M27A65428
Introduction
The Lenovo ThinkSystem DB720S Gen 7 FC SAN Switch, with its unmatched 64Gbps performance and industry-leading port density, provides a building block that supports data growth, demanding workloads, and data-center consolidation. Delivering unmatched 64Gbps performance and 50% lower latency compared to the previous generation, this switch delivers a fixed-port building block, designed to maximize the performance of flash and NVMe environments to meet demanding workloads. With Brocade® Gen 7 technology, the DB720S delivers far more than just speed and latency improvements. It can eliminate the pain of managing your data center, with autonomous SAN technology to deliver a network that can self-learn, self-optimize, and self-heal without intervention.
The Lenovo DB720 is built for maximum flexibility, scalability, and ease of use. Organizations can scale from 24 to 64 SFP+ ports in an efficient 1U form factor that delivers industry-leading port density and space utilization.
The following figure shows the Lenovo ThinkSystem DB720S Gen 7 FC SAN Switch.
Did you know?
The DB720S is designed for maximum flexibility and value. This enterprise-class switch offers pay-as-you-grow scalability with Ports on Demand (PoD). Organizations can quickly, easily, and cost-effectively scale from 24 ports to 64 ports in an efficient 1U form factor that delivers industry-leading port density and space utilization. This switch also provides easy integration into existing SAN environments -- from 8Gb to 64Gb speeds -- while introducing the benefits of Gen 7 Fibre Channel connectivity. And the DB720S simplifies deployment, configuration, and management of SAN resources with a collection of easy-to-use tools.
With Lenovo FC SAN switch offerings, Lenovo can be your trusted partner that offers "one stop shop" and single point of contact for delivery of leading edge technologies and innovations from Lenovo and other leading IT vendors. These offerings can satisfy the wide range of your end-to-end IT infrastructure needs, including end-user devices, servers, storage, networking, services, management software, and financing.
Key features
The DB720S provides exceptional price/performance value by including standard enterprise class software standard like Fabric Vision®, ISL Trunking, Integrated Routing, and Extended Fabrics.
The ThinkSystem DB720S FC SAN Switch offers the following features and benefits:
- Provides high scalability in an ultra-dense, 1U switch with up to 56 ports, providing up to 64 connections with the use of SFP-DD transceivers, to support high-density server virtualization, cloud architectures, and flash-based storage environments.
- Increases scalability by using SFP-DD transceivers that provide dual SN connections that allow organizations to connect more servers, storage, or switches in a small footprint. Each transceiver supports two independent connections of 64G Fibre Channel via a two-lane electrical interface.
- Accelerates critical workloads with 64Gb/s links
- Maximizes performance of NVMe storage with 50% lower switching latency than Gen 6
- Enables pay-as-you-grow scalability from 24 to 64 ports—for on-demand flexibility
- Safeguards mission-critical workloads from vulnerabilities with Gen 7 integrated security.
- Provides cyber-resiliency with integrated security technology that protects mission-critical operations by validating the integrity of Gen 7 hardware and software.
- Guarantees critical application performance by automatically prioritizing traffic and avoiding congestion with Brocade Traffic optimizer.
- Simplifies troubleshooting by identifying and isolating issues
- Collects comprehensive telemetry data across the fabric to enable powerful analytics
- Visualizes the data to easily understand the health and performance of the SAN
- Automates repetitive tasks to save time and eliminate human error
- Protects existing device investments with auto-sensing 8, 16 and 32 Gbit/sec capabilities and native operation with any Brocade SAN fabrics.
- Leverages Fabric Vision technology’s powerful monitoring, management, and diagnostic tools to simplify administration, increase uptime, and reduce costs.
- Supplies a rich set of standard features at no extra cost, including fabric services, advanced zoning, adaptive networking, full fabric and access gateway operations, integrated 10 Gb FC, and diagnostic tools.
- Expands fabric capabilities with optional licensed functions, including trunking, advanced monitoring and alerting, long-distance fabrics, and FC-FC routing.
- Compresses in-flight data on up to four ports for more efficient link utilization.
- Maximizes resiliency with redundant hot-swap power supplies.
- Accelerates troubleshooting with built-in advanced diagnostics tools featuring ClearLink Diagnostics with D_Ports (Diagnostic Ports) and select adapters from QLogic and Emulex, which helps ensure optical and signal integrity for 32/64 Gb Fibre Channel optics and cables.
Brocade Fabric Vision
To further simplify operations and increase visibility, the DB720S includes Brocade Fabric Vision® technology to monitor and analyze the SAN. This technology provides visibility and insight to quickly identify problems and achieve critical service-level agreements (SLAs).
The DB720S Switch with Fabric Vision technology provides a robust analytics architecture that delivers autonomous SAN technology through self-learning, self-optimizing, and self-healing capabilities. Fabric Vision technology is a suite of features that leverage comprehensive data collection capabilities with powerful analytics to quickly understand the health and performance of the environment and identify any potential impacts or trending problems. The combination of SAN analytics and automation technologies unlocks the capabilities to deliver a self-learning, self-optimizing, and self-healing autonomous SAN.
Features of Fabric Vision include:
- Self-learning
- Gather and transform billions of data points into network intelligence
- Visualize application and device-based performance and health metrics
- Detect abnormal traffic behaviors and degraded performance
- Eliminate operational steps by automatically learning application flows
- Self-optimizing
- Optimize critical application performance by automatically prioritizing traffic
- Guarantee application performance by proactively monitoring and actively shaping traffic
- Eliminate human errors and performance impacts through open DevOps automation technology
- Optimize administrative resources with cloud-like SAN orchestration
- Self-healing
- Instantly notify end devices of congestion for automatic resolution
- Ensure data delivery with automatic failover from physical or congestion issues
- Detect and automatically reconfigure out-of-compliance fabrics
- Eliminate performance impacts by automatically taking corrective action on misbehaving devices
Brocade SANnav Management Portal
To streamline management workflows, organizations can leverage the optional subscription-based Brocade SANnav Management Portal software to accelerate the deployment of new applications, switches, servers, and storage. Furthermore, a modernized graphical user interface (GUI) improves operational efficiencies with visual dashboards for instant visibility and faster troubleshooting.
EZSwitchSetup
With EZSwitchSetup, organizations can reduce the number of steps to deploy and configure a switch. In addition, the simplified user interface of Brocade Web Tools makes the SAN easier to manage. For more information, see the EZSwitchSetup User Guide, available from https://docs.broadcom.com/doc/FOS-90x-EZSwitch-UG.
Perfect for high-performance, latency-sensitive workloads
Enterprises are quickly moving their high-performance, latency-sensitive workloads to NVMe flash-based storage. The DB720S Switch supports NVMe over Fibre Channel, enabling organizations to integrate Gen 7 Fibre Channel networks with next-generation flash storage, without a disruptive rip-and-replace. This enables enterprises to achieve faster application response times and harness the performance innovation inherent in NVMe storage. NVMe, combined with the high performance and low latency of Gen 7 Fibre Channel, delivers the performance, application response time, and scalability needed for next-generation data centers.
Access Gateway
The DB720S can be deployed as a full-fabric switch or as an Access Gateway, which simplifies fabric topologies and allows heterogeneous fabric connectivity (the default mode setting is a switch). Access Gateway mode utilizes N_Port ID Virtualization (NPIV) switch standards to present physical and virtual servers directly to the core of SAN fabrics. Access Gateway allows you to configure your fabric to handle additional devices without increasing the number of switch domains. Key benefits of Access Gateway mode include the following:
- Improved scalability for large or rapidly growing server and virtual server environments
- Reduced management of the network edge, since Access Gateway does not have a domain identity and appears transparent to the core fabric
- Support for heterogeneous SAN configurations without reduced functionality for server connectivity
System specifications
The following table lists the ThinkSystem DB720S system specifications.
Models
The following table lists the ThinkSystem DB720S FC SAN Switch models.
The DB720S FC SAN Switch part numbers include the following items:
- One FC SAN Switch
- Model CTO1WW/CTO3WW: With 24 ports activated and 24x 32 Gb FC SWL SFP+ transceivers included
- Model CTO2WW/CTO4WW: With 24 ports activated and 24x 64 Gb FC SWL SFP+ transceivers included
- Serial cable (Mini-USB console cable to DB-9/RJ-45)
- Rubber feet for setting up the switch as a standalone unit
- Universal rack mount kit, 4-post & installation guide
- Web pointer document (Downloading FOS, EZSwitch, SANnav and Docs)
- Firmware Download Instructions Flyer (Instructions for downloading publicly-available Brcd docs + docs behind CSP + access to open source code.)
Note: The switch comes standard without power cords; two power cables must be purchased together with the switch (see Power supplies and cables for details).
Port activation licenses
The DB720S FC SAN Switch Model includes 24 licensed ports and 24 x 32/64 GB FC SWL SFP+ Transceivers depending on the model. The remaining 32 unlicensed ports can be activated by purchasing and installing the Ports on Demand (POD) licenses that are available with transceivers in 8-port increments.
The following table lists additional POD options for the DB720S FC SAN Switch.
Transceivers and cables
With the flexibility of the DB720S FC SAN Switch, customers can choose the following connectivity technologies:
- SFP-DD (double density) ports
- For 64 Gbps FC links, customers can use 64 Gb FC SFP-DD SWL optical transceivers for distances up to 100 meters on OM4 or up to 70 meters on OM3 50 µ MMF cables. These transceivers can operate at 64 Gbps, 32 Gbps, or 16 Gbps speeds.
- SFP+ ports
- For 64 Gbps FC links, customers can use 64 Gb FC SFP+ SWL optical transceivers for distances up to 100 meters on OM4 or up to 70 meters on OM3 50 µ MMF cables. For longer distances, the 64 Gb FC LWL SFP+ optical transceivers can support up to 10 km on SMF cables. For extended distances, the 64 Gb FC ELWL SFP+ optical transceivers can support up to 25 kilometers on SMF cables. These transceivers can operate at 64 Gbps, 32 Gbps, or 16 Gbps speeds.
- For 32 Gbps FC links, customers can use 32 Gb FC SFP+ SWL optical transceivers for distances up to 100 meters on OM4 or up to 70 meters on OM3 50 µ MMF cables. For longer distances, the 32 Gb FC LWL SFP+ optical transceivers can support up to 10 km on SMF cables. For extended distances, the 32 Gb FC ELWL SFP+ optical transceivers can support up to 25 kilometers on SMF cables. These transceivers can operate at 32 Gbps, 16 Gbps, or 8 Gbps speeds. (Except ELWL part number 4M27A65431 which can only operate at 32Gbps and 16 Gbps).
- For 10 Gbps FC links, customers can use 10 Gb FC SFP+ SWL transceivers for distances up to 125 meters on OM4 or up to 100 meters on OM3 50 µ MMF cables, or 10 Gb FC SFP+ LWL transceivers for distances up to 10 km on SMF cables. 10 Gb FC operations allow metro connectivity by directly utilizing a fiber optic cable between sites or by creating multiple channels on an optical cable between sites, utilizing Wave Division Multiplexing (WDM) technology (the Extended Fabric feature is NOT required for long distance 10 Gb FC connectivity).
- 1 GbE RJ-45 management port: Customers can use UTP cables for distances up to 100 meters.
The DB720S FC SAN Switch comes with 24x 32 Gb or 64 Gb FC SWL SFP+ transceivers. Additional SWL, LWL, and ELWL SFP+ transceivers can be ordered for the switch, if needed.
The following table lists the supported transceiver and cable options. POD kits and switches come with SWL optics included.
* The specific ELWL only operates at 32 Gbps and 16Gbps.
** ELWL Requires same optic type/part number on both ends (no-mixing) to assure interoperability.
The following table lists the cabling requirements for the switch.
Transceiver | Standard | Cable | Connector |
---|---|---|---|
64 Gb Fibre Channel | |||
64 Gb FC SWL SFP+ (4M27A65425, 4M27A65426) | FC-PI-6 |
Up to 30 m with LC-LC MMF cables supplied by Lenovo (see Table 4) or the following 850 nm 50 µ MMF cables:
|
LC |
64 Gb FC LWL SFP+ (4M27A65433, 4M27A65434) | FC-PI-6 |
1310 nm 9 µ SMF cable:
|
LC |
64 Gb FC ELWL SFP+ (4M27A65432) | FC-PI-5 |
1310 nm 9 µ SMF cable:
|
LC |
32 Gb Fibre Channel | |||
32 Gb FC SWL SFP+ (4M27A65416, 4M27A65417) | FC-PI-6 |
Up to 30 m with LC-LC MMF cables supplied by Lenovo (see Table 4), or the following 850 nm 50 µ MMF cables:
|
LC |
32 Gb FC LWL SFP+ (4M27A65418, 4M27A65419) | FC-PI-6 |
1310 nm 9 µ SMF cable:
|
LC |
32 Gb FC ELWL SFP+ (4M27A65424, 4M27A65431) | FC-PI-6 |
1310 nm 9 µ SMF cable:
|
LC |
10 Gb Fibre Channel | |||
10Gb FC SWL SFP+ (4M27A65420) | FC-10GFC |
850 nm 50 µ MMF cable:
|
LC |
10Gb FC LWL SFP+ (4M27A65421) | FC-10GFC |
1310 nm 9 µ SMF cable:
|
LC |
10 Gb FC SWL SFP+ (00YH933) | FC-10GFC |
850 nm 50 µ MMF cable:
|
LC |
10 Gb FC LWL SFP+ (00YH929) | FC-10GFC |
1310 nm 9 µ SMF cable:
|
LC |
Management ports | |||
Serial console port (mini-USB). | RS-232 | Mini-USB console cable to DB-9/RJ-45 (included with the switch). | RJ45 |
10/100/1000 Mb Ethernet port | 1000BASE-T |
Up to 25 m with UTP cables supplied by Lenovo (see Table 4) or other UTP Category 5, 5E, and 6 up to 100 meters. |
RJ45 |
Firmware
For details on features supported with the DB720S FC SAN Switch look for the latest Administration Guide for the latest available Fabric OS version:
https://www.broadcom.com/products/fibre-channel-networking/software/fabric-operating-system
The following features comes standard with the DB720S FC SAN Switch:
- Enterprise Bundle
- ISL Trunking (TRK): Allows frame-based consolidation of up to 8 inter-switch links (ISLs) into fault-tolerant and load-balanced trunks with bandwidth of up to 256 Gbps.
- Fabric Vision (FV)
- Monitoring and Alerting Policy Suite (MAPS): Provides a policy-based, fabric-wide threshold monitoring and alerting tool.
- Flow Vision: Identifies, monitors, and analyzes specific application flows.
- VM Insight: Seamlessly monitors health and performance of individual Virtual Machines (VMs) to quickly identify abnormal VM behavior and enable administrators to proactively facilitate troubleshooting and fault isolation, helping to ensure performance and operational stability.
- IO Insight: Proactively monitors I/O performance and behavior to gain deep insight into issues and ensure service levels by non-disruptively and non-intrusively gathering I/O statistics for storage traffic and applying this information within a policy-based monitoring and alerting suite to configure thresholds and alarms.
- Fabric Performance Impact (FPI) Monitoring: Leverages predefined MAPS policies to automatically identify and isolate devices that cause network performance issues by detecting different latency severity levels, and to alert administrators.
- Extended Fabric (EF): Extends Fibre Channel SANs beyond 10 km distance limitations for replication and backup at full bandwidth.
- Control Unit Port (CUP). The Control Unit Port provides an in-band management interface that the FICON host (Mainframe) can use for managing and monitoring the FC SAN switch.
- Integrated Routing: The FC-FC routing service provides Fibre Channel routing between two or more fabrics without merging those fabrics.
Management software
Lenovo offers optional Brocade SANnav™ Management Portal and SANnav Global View software license subscriptions that provide comprehensive visibility into the SAN environment, allow administrators to quickly identify, isolate, and correct problems, and accelerate administrative tasks by simplifying and automating workflows.
SANnav Management Portal is a next-generation SAN management application with a simple browser-based user interface (UI) and with a focus on streamlining common workflows, such as configuration, zoning, deployment, monitoring, troubleshooting, reporting, and analytics.
Lenovo offers the following SANnav Management Portal subscriptions:
- SANnav Management Portal Base: Designed for mid-sized SANs to manage up to 600 SAN switch ports only (SAN director ports can only be managed with the Enterprise edition).
- SANnav Management Portal Enterprise: Designed for enterprise-class SANs to manage up to 15 000 SAN switch and director ports.
SANnav Management Portal supports all Brocade SAN switches and platforms that run the Fabric OS® version 7.4 or above, including Lenovo B300, B6505, B6510, DB610S, DB620S, DB400D, DB720S, DB730S, DB800D, Brocade Directors, and FC5022.
With SANnav Global View, administrators can quickly visualize the health, performance, and inventory of multiple SANnav Management Portal instances using a simple, intelligent dashboard and can easily navigate from a global view down to local environments to investigate points of interest. SANnav Global View is designed to manage up to 20 SANnav Management Portal instances.
For more information, refer to the SANnav Management Portal documentation:
http://www.broadcom.com/products/fibre-channel-networking/software/sannav-management-portal#documentation
The following table lists ordering information for the optional SANnav Management Portal and SANnav Global View management tools. After a client has an active SANnav license, Lenovo offers a “license extension/renewal”. This offering provides our clients the flexible to extend their subscription down to a specific end date. This allows clients the ability to align to your company’s budget or align with warranty of your FC SAN switches/directors. Please engage directly with your Lenovo sales representative for more details.
The SANnav licenses are subscription-based with 1-year, 3-year, or 5-year software entitlement and support.
Fibre Channel standards
The DB720S FC SAN Switch supports the standards listed at the following web page:
https://www.broadcom.com/support/fibre-channel-networking/san-standards/standards-compliance
Power supplies and cables
The DB720S FC SAN Switch ships with two redundant hot-swap 350 W AC power supplies. Each power supply has an IEC 309-C14 connector.
The switch comes standard without a power cord; two rack power cables or line cords must be ordered together with the switch (see the following table).
* Available for factory-built custom configurations and solutions only.
Rack installation
The DB720S FC SAN Switch comes standard with the fixed rack mount kit that can be used for 4-post rack installations. If needed, the DB720S FC SAN Switch can be mounted in a 2-post rack cabinet by using the optional mid-mount rack kit that is listed in the following table.
Part number | Feature code | Description |
---|---|---|
01KN770 | AVG7 | Lenovo Mid-mount Rack Kit |
The optional mid-mount rack kit for the DB720S FC SAN Switch is shown in the following figure.
Physical specifications
The DB720S FC SAN Switch has the following dimensions and weight (approximate):
- Height: 44 mm (1.7 in.)
- Width: 440 mm (17.3 in.)
- Depth: 356 mm (14.0 in.)
- Weight: 7.17 kg (15.8 lb) with two power supply FRUs, without transceivers
Operating environment
The DB720S FC SAN Switch is supported in the following environment:
- Air temperature:
- Operating: 0°C to 40°C (32°F to 104°F)
- Non-operating: -25°C to +70°C (-13°F to 158°F)
- Maximum altitude:
- Operating: 3,000 m (9,842 ft)
- Non-operating: 12,000 m (39,370 ft)
- Humidity:
- Operating: 8% to 90% non-condensing
- Non-operating: 8% to 90% non-condensing
- Electrical power:
- AC Voltage range: 90V to 264V, maximum input current 4.5A
- AC Frequency: 50 Hz to 60 Hz nominal, 47 Hz to 63 Hz range
- Power consumption (differs based on VAC input @100 or @200):
- Idle: 56-58W (No optics)
- Maximum: 349W with all 64 ports operating at 64G (48 ports populated with 64G SWL transceivers and 8 ports populated with 2x64G SFP-DD SWL transceivers).
- Heat dissipation (differs based on VAC input @100 or @200):
- Idle: 191-196 BTU per hour (no optics)
- Maximum: 881-1192 BTU per hour
- Acoustical noise emission: 65 dB maximum
Warranty upgrades and post-warranty support
The DB720S FC SAN Switch, machine type 7D5J, has a three-year warranty.
Our global network of regional support centers offers consistent, local-language support enabling you to vary response times and level of service to match the criticality of your support needs:
- Standard Next Business Day – Best choice for non-essential systems requiring simple maintenance.
- Premier Next Business Day – Best choice for essential systems requiring technical expertise from senior-level Lenovo engineers.
- Premier 24x7 4-Hour Response – Best choice for systems where maximum uptime is critical.
- Premier Enhanced Storage Support 24x7 4-Hour Response – Best choice for storage systems where maximum uptime is critical.
For more information, consult the brochure Lenovo Operational Support Services for Data Centers Services.
Services
Lenovo Data Center Services empower you at every stage of your IT lifecycle. From expert advisory and strategic planning to seamless deployment and ongoing support, we ensure your infrastructure is built for success. Our comprehensive services accelerate time to value, minimize downtime, and free your IT staff to focus on driving innovation and business growth.
Note: Some service options may not be available in all markets or regions. For more information, go to https://lenovolocator.com/. For information about Lenovo service upgrade offerings that are available in your region, contact your local Lenovo sales representative or business partner.
In this section:
- Lenovo Advisory Services
- Lenovo Plan & Design Services
- Lenovo Deployment, Migration, and Configuration Services
- Lenovo Support Services
- Lenovo Managed Services
- Lenovo Sustainability Services
Lenovo Advisory Services
Lenovo Advisory Services simplify the planning process, enabling customers to build future-proofed strategies in as little as six weeks. Consultants provide guidance on projects including VM migration, storage, backup and recovery, and cost management to accelerate time to value, improve cost efficiency, and build a flexibly scalable foundation.
- Assessment Services
An Assessment helps solve your IT challenges through an onsite, multi-day session with a Lenovo technology expert. We perform a tools-based assessment which provides a comprehensive and thorough review of a company's environment and technology systems. In addition to the technology based functional requirements, the consultant also discusses and records the non-functional business requirements, challenges, and constraints. Assessments help organizations like yours, no matter how large or small, get a better return on your IT investment and overcome challenges in the ever-changing technology landscape.
- Design Services
Professional Services consultants perform infrastructure design and implementation planning to support your strategy. The high-level architectures provided by the assessment service are turned into low level designs and wiring diagrams, which are reviewed and approved prior to implementation. The implementation plan will demonstrate an outcome-based proposal to provide business capabilities through infrastructure with a risk-mitigated project plan.
Lenovo Plan & Design Services
Unlock faster time to market with our tailored, strategic design workshops to align solution approaches with your business goals and technical requirements. Leverage our deep solution expertise and end-to-end delivery partnership to meet your goals efficiently and effectively.
Lenovo Deployment, Migration, and Configuration Services
Optimize your IT operations by shifting labor-intensive functions to Lenovo's skilled technicians for seamless on-site or remote deployment, configuration, and migration. Enjoy peace of mind, faster time to value, and comprehensive knowledge sharing with your IT staff, backed by our best-practice methodology.
- Deployment Services for Storage and ThinkAgile
A comprehensive range of remote and onsite options tailored specifically for your business needs to ensure your storage and ThinkAgile hardware are fully operational from the start.
- Hardware Installation Services
A full-range, comprehensive setup for your hardware, including unpacking, inspecting, and positioning components to ensure your equipment is operational and error-free for the most seamless and efficient installation experience, so you can quickly benefit from your investments.
- DM/DG File Migration Services
Take the burden of file migration from your IT’s shoulders. Our experts will align your requirements and business objectives to the migration plans while coordinating with your team to plan and safely execute the data migration to your storage platforms.
- DM/DG/DE Health Check Services
Our experts perform proactive checks of your Firmware and system health to ensure your machines are operating at peak and optimal efficiency to maximize up-time, avoid system failures, ensure the security of IT solutions and simplify maintenance.
- Factory Integrated Services
A suite of value-added offerings provided during the manufacturing phase of a server or storage system that reduces time to value. These services aim at improving your hardware deployment experience and enhance the quality of a standard configuration before it arrives at your facility.
Lenovo Support Services
In addition to response time options for hardware parts, repairs, and labor, Lenovo offers a wide array of additional support services to ensure your business is positioned for success and longevity. Our goal is to reduce your capital outlays, mitigate your IT risks, and accelerate your time to productivity.
- Premier Support for Data Centers
Your direct line to the solution that promises the best, most comprehensive level of support to help you fully unlock the potential of your data center.
- Premier Enhanced Storage Support (PESS)
Gain all the benefits of Premier Support for Data Centers, adding dedicated storage specialists and resources to elevate your storage support experience to the next level.
- Committed Service Repair (CSR)
Our commitment to ensuring the fastest, most seamless resolution times for mission-critical systems that require immediate attention to ensure minimal downtime and risk for your business. This service is only available for machines under the Premier 4-Hour Response SLA.
- Multivendor Support Services (MVS)
Your single point of accountability for resolution support across vast range of leading Server, Storage, and Networking OEMs, allowing you to manage all your supported infrastructure devices seamlessly from a single source.
- Keep Your Drive (KYD)
Protect sensitive data and maintain compliance with corporate retention and disposal policies to ensure your data is always under your control, regardless of the number of drives that are installed in your Lenovo server.
- Technical Account Manager (TAM)
Your single point of contact to expedite service requests, provide status updates, and furnish reports to track incidents over time, ensuring smooth operations and optimized performance as your business grows.
- Enterprise Software Support (ESS)
Gain comprehensive, single-source, and global support for a wide range of server operating systems and Microsoft server applications.
For more information, consult the brochure Lenovo Operational Support Services for Data Centers.
Lenovo Managed Services
Achieve peak efficiency, high security, and minimal disruption with Lenovo's always-on Managed Services. Our real-time monitoring, 24x7 incident response, and problem resolution ensure your infrastructure operates seamlessly. With quarterly health checks for ongoing optimization and innovation, Lenovo's remote active monitoring boosts end-user experience and productivity by keeping your data center's hardware performing at its best.
Lenovo Managed Services provides continuous 24x7 remote monitoring (plus 24x7 call center availability) and proactive management of your data center using state-of-the-art tools, systems, and practices by a team of highly skilled and experienced Lenovo services professionals.
Quarterly reviews check error logs, verify firmware & OS device driver levels, and software as needed. We’ll also maintain records of latest patches, critical updates, and firmware levels, to ensure you systems are providing business value through optimized performance.
Lenovo Sustainability Services
- Asset Recovery Services
Lenovo Asset Recovery Services (ARS) provides a secure, seamless solution for managing end-of-life IT assets, ensuring data is safely sanitized while contributing to a more circular IT lifecycle. By maximizing the reuse or responsible recycling of devices, ARS helps businesses meet sustainability goals while recovering potential value from their retired equipment. For more information, see the Asset Recovery Services offering page.
- CO2 Offset Services
Lenovo’s CO2 Offset Services offer a simple and transparent way for businesses to take tangible action on their IT footprint. By integrating CO2 offsets directly into device purchases, customers can easily support verified climate projects and track their contributions, making meaningful progress toward their sustainability goals without added complexity.
- Lenovo Certified Refurbished
Lenovo Certified Refurbished offers a cost-effective way to support IT circularity without compromising on quality and performance. Each device undergoes rigorous testing and certification, ensuring reliable performance and extending its lifecycle. With Lenovo’s trusted certification, you gain peace of mind while making a more sustainable IT choice.
Lenovo TruScale
Lenovo TruScale XaaS is your set of flexible IT services that makes everything easier. Streamline IT procurement, simplify infrastructure and device management, and pay only for what you use – so your business is free to grow and go anywhere.
Lenovo TruScale is the unified solution that gives you simplified access to:
- The industry’s broadest portfolio – from pocket to cloud – all delivered as a service
- A single-contract framework for full visibility and accountability
- The global scale to rapidly and securely build teams from anywhere
- Flexible fixed and metered pay-as-you-go models with minimal upfront cost
- The growth-driving combination of hardware, software, infrastructure, and solutions – all from one single provider with one point of accountability.
For information about Lenovo TruScale offerings that are available in your region, contact your local Lenovo sales representative or business partner.
Regulatory compliance
The DB720S FC SAN Switch conforms to the following regulations which can be found in the Hardware Installation Guide, available from the following web page:
https://www.broadcom.com/products/fibre-channel-networking/switches/g720-switch
Interoperability
For end-to-end storage configuration support, refer to the Lenovo Storage Interoperation Center (LSIC):
https://datacentersupport.lenovo.com/us/en/lsic
Use the LSIC to select the known components of your configuration and then get a list all other supported combinations, with details about supported hardware, firmware, operating systems, and drivers, plus any additional configuration notes. View results on screen or export them to Excel.
External storage systems
Lenovo offers the ThinkSystem DE Series and ThinkSystem DM Series external storage systems for high-performance storage. See the DE Series and DM Series product guides for specific controller models, expansion enclosures and configuration options:
- ThinkSystem DE Series Storage
https://lenovopress.com/storage/thinksystem/de-series#rt=product-guide - ThinkSystem DM Series Storage
https://lenovopress.com/storage/thinksystem/dm-series#rt=product-guide - ThinkSystem DG Series Storage
https://lenovopress.com/storage/thinksystem/dg-series#rt=product-guide
External backup units
The following table lists the external backup options that are offered by Lenovo that can be used in Lenovo FC SAN solutions.
Note: Information provided in this section is for ordering reference purposes only. End-to-end LTO Ultrium configuration support for a particular tape backup unit must be verified through the System Storage Interoperation Center (SSIC):
http://www.ibm.com/systems/support/storage/ssic
For more information, see the list of Product Guides in the Tape Autoloaders and Libraries category:
https://lenovopress.com/storage/tape/library
Rack cabinets
The following table lists the supported rack cabinets.
For specifications about these racks, see the Lenovo Rack Cabinet Reference, available from:
https://lenovopress.com/lp1287-lenovo-rack-cabinet-reference
For more information, see the list of Product Guides in the Rack cabinets category:
https://lenovopress.com/servers/options/racks
Power distribution units
The following table lists the power distribution units (PDUs) that are offered by Lenovo.
For more information, see the Lenovo Press documents in the PDU category:
https://lenovopress.com/servers/options/pdu
Uninterruptible power supply units
The following table lists the uninterruptible power supply (UPS) units that are offered by Lenovo.
† Only available in China and the Asia Pacific market.
For more information, see the list of Product Guides in the UPS category:
https://lenovopress.com/servers/options/ups
Seller training courses
The following sales training courses are offered for employees and partners (login required). Courses are listed in date order.
-
Family Portfolio: Storage Networking
2024-10-14 | 15 minutes | Employees and Partners
DetailsFamily Portfolio: Storage NetworkingThis course will provide you an overview of the Storage Networking family. After completing this course, you should be able to identify the products in the Storage Networking portfolio and their features, describe product family benefits, and recognize when a specific product should be used.
Published: 2024-10-14
Length: 15 minutesStart the training:
Employee link: Grow@Lenovo
Partner link: Lenovo Partner Learning -
Partner Technical Webinar - Fibre Channel Market Tranistions
2024-10-08 | 60 minutes | Employees and Partners
DetailsPartner Technical Webinar - Fibre Channel Market Tranistionsin this 60-minute replay, there were two topics. Mike Easterly, Fibre Channel Technical Sales Executive for Broadcom, reviewed the Fibre Channel offerings. He described then need to focus on Gen 7 over Gen5 & Gen6. He described the many security features of Fibre Channel and why Fibre Channel is the gold standard of storage networking. Herb Ducey, Lenovo Storage Product Manager concluded with updates on the storage product line including DM Series, DE Series and D3284 updates.
Published: 2024-10-08
Length: 60 minutesStart the training:
Employee link: Grow@Lenovo
Partner link: Lenovo Partner Learning -
Lenovo Data Center Product Portfolio
2024-05-29 | 20 minutes | Employees and Partners
DetailsLenovo Data Center Product PortfolioThis course introduces the Lenovo data center portfolio, and covers servers, storage, storage networking, and software-defined infrastructure products. After completing this course about Lenovo data center products, you will be able to identify product types within each data center family, describe Lenovo innovations that this product family or category uses, and recognize when a specific product should be selected.
Published: 2024-05-29
Length: 20 minutesStart the training:
Employee link: Grow@Lenovo
Partner link: Lenovo Partner Learning -
Simplify Selling Fibre Channel Storage Solutions
2024-04-23 | 45 minutes | Employees and Partners
DetailsSimplify Selling Fibre Channel Storage SolutionsIn this session we look at the benefits of Fibre Channel and the benefits to you and your customers of bundling FC networking with your storage arrays.
Published: 2024-04-23
Plus, we will take a closer look at some of the changes Lenovo has made to the Data Center Solutions Configurator to help you and the clients build bundled FC solutions.
Course Objectives:
1. Learn the benefits of Fibre Channel
2. Understand the benefits of bundling FC networking with your storage arrays
3. Discover the latest updates in DCSC (Data Center Solutions Configurator)
Length: 45 minutesStart the training:
Employee link: Grow@Lenovo
Partner link: Lenovo Partner Learning -
Partner Technical Webinar - Fibre Channel and DG Updates
2024-04-23 | 60 minutes | Employees and Partners
DetailsPartner Technical Webinar - Fibre Channel and DG UpdatesIn this 60-minute replay, Mike Easterly, Broadcom, reviewed Lenovo solutions for Fibre Channel (FC) including Emulex FC Adapters and Brocade FC switches. Next, Mark Clayton, Lenovo Storage Architect, reviewed the lasted on the Data Management portfolio with updates on DG, HS350x Ready Nodes and Data Protection.
Published: 2024-04-23
Length: 60 minutesStart the training:
Employee link: Grow@Lenovo
Partner link: Lenovo Partner Learning -
VTT Data Management How to sell storage - April 2024
2024-04-10 | 60 minutes | Employees Only
DetailsVTT Data Management How to sell storage - April 2024In this course, you will know:
Published: 2024-04-10
- Why do we sell storage?
- What are the basics you need to get an opportunity rolling?
- Why Lenovo for Storage?
- What is happening in the market today?
- How to determine traction?
Length: 60 minutesStart the training:
Employee link: Grow@Lenovo -
Selling the Gen7 ThinkSystem DB720S SAN Switch
2023-02-01 | 20 minutes | Employees and Partners
DetailsSelling the Gen7 ThinkSystem DB720S SAN SwitchThis course is designed to give Lenovo sales (general and technical) and partner representatives a foundation for the Gen7 ThinkSystem DB720S SAN switch and the Autonomous SAN solution. As an introduction to the product, this course enables the learner to identify the features and benefits of the switch and how it is integrated into the Autonomous SAN solution. By the end of this training, you should be able to: describe what is happening in the data center and the pressures surrounding the storage network; explain why the network will need to evolve to keep pace with the next wave of innovation in the data center; and describe how Gen 7 Fibre Channel enables an autonomous SAN that will harness the full value of next-gen data centers.
Published: 2023-02-01
Length: 20 minutesStart the training:
Employee link: Grow@Lenovo
Partner link: Lenovo Partner Learning -
Why Gen 7 with 64G Fibre Channel
2022-03-17 | 20 minutes | Employees and Partners
DetailsWhy Gen 7 with 64G Fibre ChannelIn this course we will be discussing what is happening in the data center and the pressures surrounding the network. We will look at why the network will need to evolve to keep pace with the next wave of innovation; which creates an imbalance in performance. We will review how Gen 7 Fibre Channel enables an autonomous SAN that will harness the full value of next-gen data centers. Last, we will review the Gen 7 hardware. Let’s start with the what businesses require from their infrastructures.
Published: 2022-03-17
Course objectives:
1. Understand the benefits of clients investing in 64G Gen 7 switches today
2. Help customers have a clear understanding if 64G Gen 7 is a better fit than a Gen 6 switch for their requirements
3. Articulate to your clients that Gen 7 is more that just 64G speeds
4. Explain how Lenovo is well positioned for clients looking for the best investment protection of their infrastructure with multiple Gen 7 Fibre Channel offerings
Length: 20 minutesStart the training:
Employee link: Grow@Lenovo
Partner link: Lenovo Partner Learning
Related publications and links
For more information, see the following resources:
- Datasheet of the DB720S:
https://lenovopress.com/datasheet/ds0120-thinksystem-db720s-fc-san-switch - Interactive 3D Tour of the DB720S:
https://lenovopress.com/lp1409-3d-tour-thinksystem-db720s - Analyst report "64 Gb Fibre Channel Performance with Lenovo ThinkSystem Emulex LPe36002 Gen 7 FC HBA"
https://www.lenovo.com/us/en/resources/data-center-solutions/analyst-reports/64-gb-fibre-channel-performance-with-lenovo-thinksystem-emulex-lpe36002-gen-7-test-report/ - Lenovo ThinkSystem DB720S FC SAN Switch product publications - see the Brocade G720 documentation:
https://www.broadcom.com/products/fibre-channel-networking/switches/g720-switchTip: Some of the Fabric OS documents can be accessed via the support portal by validating your serial number for software entitlement
- Hardware Installation Guide
- Fabric OS Access Gateway Administration Guide
- Fabric OS Administration Guide
- Fabric OS Extension Configuration Guide
- Fabric OS Troubleshooting and Diagnostics Guide
- Fabric OS Command Reference
- Fabric OS Message Reference
- Fabric OS MIB Reference
- Web Tools Administration Guide
- Flow Vision Configuration Guide
- Monitoring and Alerting Policy Suite Configuration Guide
- Brocade 64G SWL SFP-DD Product Brief:
https://docs.broadcom.com/docs/SFP-DD-64G-SWL-PB - EZSwitchSetup User Guide:
https://docs.broadcom.com/doc/FOS-90x-EZSwitch-UG - Lenovo Data Center Support for the ThinkSystem DB720S FC SAN Switch:
https://datacentersupport.lenovo.com/us/en/products/storage/fibre-channel-switches/db720s-fc-switch/7d5j
Trademarks
Lenovo and the Lenovo logo are trademarks or registered trademarks of Lenovo in the United States, other countries, or both. A current list of Lenovo trademarks is available on the Web at https://www.lenovo.com/us/en/legal/copytrade/.
The following terms are trademarks of Lenovo in the United States, other countries, or both:
Lenovo®
ThinkAgile®
ThinkSystem®
The following terms are trademarks of other companies:
Microsoft® and Excel® are trademarks of Microsoft Corporation in the United States, other countries, or both.
Other company, product, or service names may be trademarks or service marks of others.
Configure and Buy
Full Change History
Changes in the September 9, 2024 update:
- Updated a typographical error under Transceivers and cables section:
- Brocade Secure 64-Gb SWL SFP-DD Transceiver, 4M27A65427
- Brocade Secure 64-Gb SWL SFP-DD Transceiver 8-pack, 4M27A65428
Changes in the October 13, 2022 update:
- The following interface is withdrawn:
- EZSwitch management interface
Changes in the July 26, 2022 update:
- New ELWL and LWL transceivers - Transceivers and cables section:
- Brocade Secure 32Gb ELWL SFP+ V2 Transceiver (25 km), 4M27A65431
- Brocade Secure 64Gb ELWL SFP+ Transceiver (25 km), 4M27A65432
- Brocade Secure 64Gb LWL SFP+ Transceiver (10 km), 4M27A65433
- Brocade Secure 64Gb LWL SFP+ Transceiver (10 km) 8-pack, 4M27A65434
Changes to the April 19, 2022 update:
- New support for SFP-DD (double-density) transceivers and cables which allow two 64Gb SFP+ connections in each of the 8 supported physical ports on the switch
- New port activation license with transceivers - Port activation licenses section
- DB720S 16-Port SW License with 8x 64 Gbps SWL SFP-DD transceivers, 4M27A65821
- New OM4 SN to LC (SFP-DD to SFP) optical cables for 64 Gb FC SW SFP-DD transceivers - Transceivers and cables section
- Lenovo 1M SN-LC SFP-DD OM4 FC Cable, 4X97A81905
- Lenovo 3M SN-LC SFP-DD OM4 FC Cable, 4X97A81907
- Lenovo 5M SN-LC SFP-DD OM4 FC Cable, 4X97A81908
- Lenovo 10M SN-LC SFP-DD OM4 FC Cable, 4X97A81910
- Lenovo 15M SN-LC SFP-DD OM4 FC Cable, 4X97A81911
- Lenovo 25M SN-LC SFP-DD OM4 FC Cable, 4X97A81913
- Lenovo 30M SN-LC SFP-DD OM4 FC Cable, 4X97A81914
- New OM4 SN to SN (SFP-DD to SFP-DD) optical cables for 64 Gb FC SW SFP-DD transceivers - Transceivers and cables section
- Lenovo 1M SN-SN SFP-DD OM4 FC Cable, 4X97A81893
- Lenovo 3M SN-SN SFP-DD OM4 FC Cable, 4X97A81895
- Lenovo 5M SN-SN SFP-DD OM4 FC Cable, 4X97A81896
- Lenovo 10M SN-SN SFP-DD OM4 FC Cable, 4X97A81898
- Lenovo 15M SN-SN SFP-DD OM4 FC Cable, 4X97A81899
- Lenovo 25M SN-SN SFP-DD OM4 FC Cable, 4X97A81901
- Lenovo 30M SN-SN SFP-DD OM4 FC Cable, 4X97A81902
Changes to the January 11, 2022 update:
- Added the 10Gb FC transceivers to the cabling requirements table - Table 5 in the Transceivers and cables section
Changes to the September 9, 2021 update:
- Added a link to the analyst's report "64 Gb Fibre Channel Performance with Lenovo ThinkSystem Emulex LPe36002 Gen 7 FC HBA" - Related publications and links section
Changes in the May 13, 2021 update:
- Updated specs in the System specifications table for Fabric OS 9.0.1a - System specifications section:
- Fabric services
- Management
- Diagnostics
Changes in the March 13, 2021 update:
- The following transceivers are now withdrawn from marketing - Transceivers and cables section:
- Brocade 10G FC SWL SFP+, 00YH933
- Brocade 10G FC LWL SFP+, 00YH929
Changes in the January 26, 2021 update:
- The DB720S is now available in the DCSC configurator
- The use of 64Gb transceivers require FOS 9.0.1a or later - Models and Transceivers and cables sections
Changes in the January 8, 2021 update:
- Added that the switch as a three-year software/firmware entitlement - System specifications section
First published December 3, 2020
Course Detail
Employees Only Content
The content in this document with a is only visible to employees who are logged in. Logon using your Lenovo ITcode and password via Lenovo single-signon (SSO).
The author of the document has determined that this content is classified as Lenovo Internal and should not be normally be made available to people who are not employees or contractors. This includes partners, customers, and competitors. The reasons may vary and you should reach out to the authors of the document for clarification, if needed. Be cautious about sharing this content with others as it may contain sensitive information.
Any visitor to the Lenovo Press web site who is not logged on will not be able to see this employee-only content. This content is excluded from search engine indexes and will not appear in any search results.
For all users, including logged-in employees, this employee-only content does not appear in the PDF version of this document.
This functionality is cookie based. The web site will normally remember your login state between browser sessions, however, if you clear cookies at the end of a session or work in an Incognito/Private browser window, then you will need to log in each time.
If you have any questions about this feature of the Lenovo Press web, please email David Watts at dwatts@lenovo.com.