Abstract
The Lenovo Storage E1012 and E1024 Disk Expansion Enclosures offer universal storage expansion capabilities that are designed to provide simplicity, speed, scalability, security, and high availability for small to large businesses. The E1012 and E1024 deliver enterprise-class storage technology in a cost-effective solution with flexible drive configurations and RAID or JBOD (non-RAID) host connectivity or Lenovo storage area network (SAN) array expansion.
This product guide provides essential pre-sales information to understand the structure of the E1012 and E1024 expansion enclosure offerings, their key features and specifications, components and options, and configuration guidelines.
This guide is intended for technical specialists, sales specialists, sales engineers, IT architects, and other IT professionals who want to learn more about the E1012 and E1024 and consider their use in IT solutions.
Product availability: The E1012 and E1024 expansion units are withdrawn and no longer available for ordering. For currently available expansion units, refer to the following product guides:
- Lenovo Storage D1212 and D1224 Drive Enclosures
http://lenovopress.com/lp0512 - Lenovo Storage D3284 External High Density Drive Expansion Enclosure
http://lenovopress.com/lp0513
Change History
Changes in the May 22 update:
- The E1012 and E1024 expansion units are withdrawn and no longer available for ordering
Introduction
The Lenovo Storage E1012 and E1024 Disk Expansion Enclosures offer universal storage expansion capabilities that are designed to provide simplicity, speed, scalability, security, and high availability for small to large businesses. The E1012 and E1024 deliver enterprise-class storage technology in a cost-effective solution with flexible drive configurations and RAID or JBOD (non-RAID) host connectivity or Lenovo storage area network (SAN) array expansion.
The E1012 and E1024 expansion units are designed for a wide range of workloads, including big data and analytics, video surveillance, media streaming, private clouds, file and print serving, e-mail and collaboration, and databases.
Figure 1. Lenovo Storage E1012 and E1024 Disk Expansion Enclosures
Did you know?
The E1012 and E1024 expansion enclosures offer flexible drive configurations with the choice of 2.5-inch and 3.5-inch drive form factors, 10K or 15K rpm SAS and 7.2K rpm NL SAS hard disk drives (HDDs) and self-encrypting drives (SEDs), and SAS solid-state drives (SSDs).
With support for daisy chaining, the E1012 can be scaled up to 960 TB for capacity-optimized configurations, and the E1024 can be scaled up to 192 drives for performance-optimized configurations.
The E1012 and E1024 expansion units are universal enclosures that can be used with Lenovo System x and ThinkServer systems as direct attach storage (DAS) or as expansion for the Lenovo Storage S2200 and S3200 storage area network (SAN) arrays.
Key features
Key features and benefits provided by the E1012 and E1024 storage expansion enclosures include:
- Versatile, scalable storage expansion with a single I/O module for entry-level solutions or dual I/O module configurations for high availability and performance
- Flexible host connectivity to match diverse client needs for direct attach storage with support for 6 Gb or 12 Gb SAS RAID adapters for advanced data protection or 6 Gb SAS Host Bus Adapter (HBA) for maximum JBOD performance
- Provide expansion capabilities and share common parts with the S2200 and S3200 SAN arrays
- 6 Gb SAS drive-side connectivity with support for 12x 3.5-inch large form factor (LFF) drives in the E1012 enclosure or 24x 2.5-inch small form factor (SFF) drives in the E1024 enclosure
- Scalability of up to 96 LFF or 192 SFF drives per RAID adapter with the attachment of up to eight E1012 or E1024 daisy-chained expansion enclosures to satisfy growing needs for storage capacity and performance
- Flexibility in storing data on high performance SAS SSDs, performance-optimized enterprise SAS HDDs, or capacity-optimized enterprise NL SAS HDDs; mixing and matching drive types and form factors on a single RAID adapter to perfectly meet performance and capacity requirements for various workloads
- Self-encrypting drives with a supported RAID adapter allow clients to secure their sensitive data and to comply with various security regulations when required
- Designed to comply with NEBS and MIL-STD requirements
- Designed for 99.999% availability
The E1012 and E1024 are designed to support the complete range of data storage requirements, from highly utilized applications to high-capacity, low usage applications.
The following 3.5-inch SAS drives are supported by the E1012:
- High performance solid-state drives (10 drive writes per day [DWD]): 400 GB
- Performance-optimized, enterprise class disk drives: 600 GB and 900 GB 10K rpm
- High-capacity, archival-class nearline disk drives: 2 TB, 4 TB, 6 TB, 8 TB, and 10 TB 7.2K rpm
The following 2.5-inch SAS drives are supported by the E1024:
- High performance solid-state drives (3 DWD and 10 DWD): 400 GB, 800 GB, and 1.6 TB
- High performance self-encrypting solid-state drives (10 DWD): 400 GB and 800 GB
- Capacity-optimized solid-state drives (1 DWD): 3.84 TB
- Performance-optimized, enterprise class disk drives
- 300 GB and 600 GB 15K rpm
- 600 GB, 900 GB, 1.2 TB, and 1.8 TB 10K rpm
- High-capacity, archival-class nearline disk drives: 1 TB and 2 TB 7.2K rpm
Additional drives and expansion units are designed to be dynamically added with virtually no downtime (operating system dependent), helping to quickly and seamlessly respond to growing capacity demands.
The E1012 and E1024 expansion enclosures are designed to offer high levels of system and data availability with the following technologies:
- Dual I/O modules provide redundant paths from a supported RAID controller to the drives in the enclosures for I/O load balancing and failover
- Dual-port drives (both HDDs and SSDs) with automatic drive failure detection and RAID rebuild with global hot spares with a supported RAID adapter
- Redundant hardware, including host ports, I/O modules, and power supplies and fans
- Hot-swappable and customer replaceable components, including I/O modules, power supplies with fans, and drives
Components and connectors
The following figure shows the front of the E1012 drive expansion enclosure.
Figure 2. Front view of the E1012 drive enclosure
The following figure shows the front of the E1024 drive expansion enclosure.
Figure 3. Front view of the E1024 drive enclosure
The following figure shows the rear of the E1012 and E1024 drive enclosures with dual I/O expansion modules. Single I/O module configurations are also supported.
Figure 4. Rear view of the E1012 and E1024 drive enclosures
Note: The expansion modules (shown in Figure 4) have additional service ports with a specialized connector, and these ports are reserved for use by a Lenovo service technician.
System specifications
The following table lists the E1012 and E1024 system specifications.
Components | Specification |
Form factor | 2U rack mount |
I/O expansion configuration | Single or dual I/O Expansion Module configurations supported. Single I/O Module enclosures can be upgraded to dual I/O Module enclosures non-disruptively. |
Drive bays |
|
Drive technologies | SAS and NL SAS HDDs and SEDs; eMLC SAS SSDs. Intermix of HDDs, SEDs, and SSDs is supported within an enclosure, but not within a RAID array. |
Drive connectivity | Dual-ported 6 Gb SAS drive attachment infrastructure:
|
Drives | SFF drives:
|
Storage capacity |
|
Host connectivity | 1x 6/12 Gb SAS host port (IN) (Mini-SAS SFF-8088) per I/O Expansion Module |
Host adapters |
|
Host operating systems | Microsoft Windows Server 2008 R2, 2012 and 2012 R2; Red Hat Enterprise Linux (RHEL) 5, 6, and 7; SUSE Linux Enterprise Server (SLES) 10, 11, and 12; VMware vSphere 5.1, 5.5, and 6.0. |
Cooling | Redundant cooling with two fans that are built into power supplies. |
Power supply | Two redundant hot-swap 595 W AC power supplies. |
Hot-swap parts | I/O expansion modules, drives, power supplies/fans. |
Management interfaces | SAS Enclosure Services |
Security features | Self-encrypting drives (SEDs) |
Warranty | Three-year customer-replaceable unit, parts only limited warranty with 9x5 next business day. |
Service and support | Optional warranty service upgrades are available through Lenovo: on-site support, 24x7 coverage, 4-hour response time, 1-year or 2-year warranty extensions, Hard Drive Retention. |
Dimensions |
|
Weight |
|
Models
Product availability: The E1012 and E1024 expansion units are withdrawn and no longer available for ordering. For currently available expansion units, refer to the following product guides:
- Lenovo Storage D1212 and D1224 Drive Enclosures
http://lenovopress.com/lp0512 - Lenovo Storage D3284 External High Density Drive Expansion Enclosure
http://lenovopress.com/lp0513
The following table lists the models of the E1012 and E1024 expansion enclosures.
Description | Part number |
LFF models | |
Lenovo Storage E1012 LFF Disk Expansion Single SAS IO Module, Rail Kit, 9x5 NBD | 64111B1 |
Lenovo Storage E1012 LFF Disk Expansion Dual SAS IO Module, Rail Kit, 9x5 NBD | 64111B2 |
SFF models | |
Lenovo Storage E1024 SFF Disk Expansion Single SAS IO Module, Rail Kit, 9x5 NBD | 64111B3 |
Lenovo Storage E1024 SFF Disk Expansion Dual SAS IO Module, Rail Kit, 9x5 NBD | 64111B4 |
The part number for the E1012 or E1024 includes the following items:
- One E1012 or E1024 chassis with two power supplies with fans and with one or two SAS I/O expansion modules installed
- Two 4.3m, 10A/100-250V, C13 to IEC 320-C14 Rack Power Cables
- Lenovo Storage SAN Rack Mount Kit - Rails 25"-36"
- Getting Started Guide
- Warranty Flyer
- Important Notices Flyer
- Documentation Flyer
Connectivity topology
The E1012 and E1024 support single and dual expansion module configurations. Standard models of the E1012 and E1024 ship with one or two expansion modules (see Table 2). Single module configurations can be upgraded to dual module configurations non-disruptively.
Each expansion module has two 6 Gb SAS x4 ports (Mini-SAS SFF-8088 connectors) labeled IN and OUT. These ports are used for connections to a supported RAID adapter installed in a server and for daisy chaining the E1012 and E1024 enclosures between each other. The external port on the RAID controller is connected to the IN port on the expansion module, and the OUT port on the expansion module is connected to the IN port on the expansion module in the adjacent enclosure and so on.
Single I/O module configurations can be used with a supported RAID adapter or HBA. In this topology, each port on the adapter is connected to a separate chain of single I/O expansion enclosures, as illustrated in the following figure.
Figure 5. Single I/O module connectivity topology
Dual I/O module configurations can be used with 2-port RAID adapters for high availability and performance. In this topology, each port on the RAID adapter is connected to a different I/O module chain within the same chain of dual I/O enclosures.
Dual I/O connectivity topology without enclosure redundancy is shown in the following figure.
Figure 6. Dual I/O connectivity topology without enclosure redundancy
Dual I/O connectivity topology with enclosure redundancy is shown in the following figure.
Figure 7. Dual I/O connectivity topology with enclosure redundancy
The following table lists the maximum number of the E1012 and E1024 in a chain on the same adapter.
Single I/O chain | E1012 qty | 0 | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 |
E1024 qty | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 | |
Dual I/O chain | E1012 qty | 0 | 1 | 2 | 3 | 4 | ||||
E1024 qty | 4 | 3 | 2 | 1 | 0 |
The following table lists ordering information for the expansion modules and related connectivity options.
Description | Part number | Feature code | Max qty per one enclosure |
Expansion modules | |||
Lenovo Storage Expansion SAS IO Module | 00WC085 | AT27 | 2 |
Connectivity cables - Mini-SAS Host Adapter to Expansion and Expansion to Expansion | |||
External MiniSAS 8088/MiniSAS 8088 0.6m cable | 00WE754 | AT1A | 2* |
External MiniSAS 8088/MiniSAS 8088 1m cable | 00WE755 | AT1B | 2* |
External MiniSAS 8088/MiniSAS 8088 2m cable | 00WE756 | AT1C | 2* |
Connectivity cables - Mini-SAS HD Host Adapter to Expansion | |||
1.5m HD-miniSAS to miniSAS SAS Cable | 00D5224 | A3HX | 2* |
3m HD-miniSAS to miniSAS SAS Cable | 00D5226 | A3HY | 2* |
* One cable per SAS expansion module.
Drives
The E1012 enclosure supports up to 12 LFF hot-swap drives, and the E1024 enclosure supports up to 24 SFF hot-swap drives.
The following tables list drive options for the E1012 and E1024 drive enclosures.
Description | Part number | Feature code | Maximum qty per one E1012 |
3.5-inch SAS hot-swap HDDs | |||
Lenovo Storage 3.5" 600GB 10K SAS HDD (2.5" in 3.5") | 00WC040 | AT21 | 12 |
Lenovo Storage 3.5" 900GB 10K SAS HDD (2.5" in 3.5") | 00WC035 | AT1Z | 12 |
3.5-inch NL SAS hot-swap HDDs | |||
Lenovo Storage 3.5" 2TB 7.2k NL-SAS HDD | 00MM735 | AT1V | 12 |
Lenovo Storage 3.5" 4TB 7.2k NL-SAS HDD | 00MM730 | AT1W | 12 |
Lenovo Storage 3.5" 6TB 7.2k NL-SAS HDD | 00MM725 | AT1Y | 12 |
Lenovo Storage 3.5" 8TB 7.2k NL-SAS HDD | 00WE790 | AT47 | 12 |
Lenovo Storage 3.5" 10TB 7.2k NL-SAS HDD | 01DC631 | AU7W | 12 |
3.5-inch NL SAS hot-swap SEDs | |||
Lenovo Storage 3.5" 4TB 7.2k NL-SAS HDD (SED) | 00WC025 | AT1X | 12 |
3.5-inch SAS hot-swap SSDs (10 DWD) | |||
Lenovo Storage 3.5" 400GB SSD SAS (2.5" in 3.5" SSD1600MM) | 00WC030 | AT20 | 12 |
Lenovo Storage 3.5" 400GB 10DWD SAS SSD (2.5" in 3.5" 1200.2) | 4XB7A09596 | B16B | 12 |
Description | Part number | Feature code | Maximum qty per one E1024 |
2.5-inch SAS hot-swap HDDs | |||
Lenovo Storage 2.5" 300GB 15k SAS HDD | 00MM685 | AT1H | 24 |
Lenovo Storage 2.5" 600GB 10k SAS HDD | 00MM700 | AT1K | 24 |
Lenovo Storage 2.5" 600GB 15k SAS HDD | 00MM680 | AT1J | 24 |
Lenovo Storage 2.5" 900GB 10k SAS HDD | 00MM695 | AT1M | 24 |
Lenovo Storage 2.5" 1.2TB 10k SAS HDD | 00MM690 | AT1P | 24 |
Lenovo Storage 2.5" 1.8TB 10k SAS HDD | 00YG718 | ATSK | 24 |
2.5-inch SAS hot-swap SEDs | |||
Lenovo Storage 2.5" 600GB 10k SAS HDD (SED) | 00WC020 | AT1L | 24 |
Lenovo Storage 2.5" 900GB 10k SAS HDD (SED) | 00MM745 | AT1N | 24 |
Lenovo Storage 2.5" 1.2TB 10k SAS HDD (SED) | 00MM740 | AT1Q | 24 |
2.5-inch NL SAS hot-swap HDDs | |||
Lenovo Storage 2.5" 1TB 7.2k NL-SAS HDD | 00MM705 | AT1R | 24 |
Lenovo Storage 2.5" 2TB 7.2k NL-SAS HDD | 00YG698 | ATSL | 24 |
2.5-inch SAS hot-swap SSDs (1 DWD) (1200.2) | |||
Lenovo Storage 2.5" 3.84TB 1DWD SSD | 01CX868 | AUJN | 24 |
2.5-inch SAS hot-swap SSDs (3 DWD) (PM1635) | |||
Lenovo Storage 2.5" 400GB 3DWD SSD | 00YH988 | AU22 | 24 |
Lenovo Storage 2.5" 800GB 3DWD SSD | 00YH978 | AU21 | 24 |
Lenovo Storage 2.5" 1.6TB 3DWD SSD | 00YH968 | AU20 | 24 |
2.5-inch SAS hot-swap SSDs (10 DWD) (SSD1600MM) | |||
Lenovo Storage 2.5" 400GB SSD (SAS) | 00MM720 | AT1S | 24 |
Lenovo Storage 2.5" 800GB SSD (SAS) | 00MM715 | AT1T | 24 |
Lenovo Storage 2.5" 1.6TB SSD (SAS) | 00MM710 | AT1U | 24 |
2.5-inch SAS hot-swap SSDs (10 DWD) (1200.2) | |||
Lenovo Storage 2.5" 400GB 10DWDSAS SSD (1200.2) | 01CX697 | B16A | 24 |
Lenovo Storage 2.5" 800GB 10DWD SAS SSD (1200.2) | 01CX687 | B168 | 24 |
Lenovo Storage 2.5" 1.6TB 10DWD SAS SSD (1200.2) | 01CX682 | B167 | 24 |
2.5-inch SAS hot-swap SED SSDs (10 DWD) | |||
Lenovo Storage 2.5” 400GB 10DWD SED SSD (SSD1600MM) | 00YH983 | AU24 | 24 |
Lenovo Storage 2.5" 800GB 10DWD SED SSD (SSD1600MM) | 00YH973 | AU23 | 24 |
Lenovo Storage 2.5" 800GB 10DWD SED (FIPS) SSD (1200.2) | 01CX692 | B169 | 24 |
Power cables
The E1012 and E1024 ship standard with two 4.3m, 10A/100-250V, C13 to IEC 320-C14 Rack Power Cables. Other power cable options are also available, and the part numbers and feature codes to order the power cables (two power cables are required per each E1012 and E1024) are listed in the following table.
Description | Part number | Feature code |
Rack power cables | ||
1.2m, 10A/100-250V, 2 Short C13s to Short C14 Rack Power Cable | 47C2487 | A3SS |
1.2m, 16A/100-250V, 2 Short C13s to Short C20 Rack Power Cable | 47C2491 | A3SW |
1.5m, 10A/100-250V, C13 to IEC 320-C14 Rack Power Cable | 39Y7937 | 6201 |
2.5m, 10A/100-250V, 2 Long C13s to Short C14 Rack Power Cable | 47C2488 | A3ST |
2.5m, 16A/100-250V, 2 Long C13s to Short C20 Rack Power Cable | 47C2492 | A3SX |
2.8m, 10A/100-250V, 2 Short C13s to Long C14 Rack Power Cable | 47C2489 | A3SU |
2.8m, 10A/100-250V, C13 to IEC 320-C14 Rack Power Cable | None* | 6311 |
2.8m, 10A/100-250V, C13 to IEC 320-C20 Rack Power Cable | 39Y7938 | 6204 |
2.8m, 16A/100-250V, 2 Short C13s to Long C20 Rack Power Cable | 47C2493 | A3SY |
4.1m, 10A/100-250V, 2 Long C13s to Long C14 Rack Power Cable | 47C2490 | A3SV |
4.1m, 16A/100-250V, 2 Long C13s to Long C20 Rack Power Cable | 47C2494 | A3SZ |
4.3m, 10A/100-250V, C13 to IEC 320-C14 Rack Power Cable | 39Y7932 | 6263 |
Line cords | ||
10A/125V C13 to NEMA 5-15P 4.3m line cord | 39Y7931 | 6207 |
10A/250V C13 to NEMA 6-15P 2.8m line cord | 46M2592 | A1RF |
Argentina 10A/250V C13 to IRAM 2073 2.8m line cord | 39Y7930 | 6222 |
Australia/NZ 10A/250V C13 to AS/NZ 3112 2.8m line cord | 39Y7924 | 6211 |
Brazil 10A/250V C13 to NBR 14136 2.8m line cord | 69Y1988 | 6532 |
China 10A/250V C13 to GB 2099.1 2.8m line cord | 39Y7928 | 6210 |
Denmark 10A/250V C13 to DK2-5a 2.8m line cord | 39Y7918 | 6213 |
European 10A/230V C13 to CEE7-VII 2.8m line cord | 39Y7917 | 6212 |
India 10A/250V C13 to IS 6538 2.8m line cord | 39Y7927 | 6269 |
Israel 10A/250V C13 to SI 32 2.8m line cord | 39Y7920 | 6218 |
Italy 10A/250V C13 to CEI 23-16 2.8m line cord | 39Y7921 | 6217 |
Japan 12A/125V C13 to JIS C-8303 2.8m line cord | 46M2593 | A1RE |
Korea 12A/250V C13 to KETI 2.8m line cord | 39Y7925 | 6219 |
South Africa 10A/250V C13 to SABS 164 2.8m line cord | 39Y7922 | 6214 |
Switzerland 10A/250V C13 to SEV 1011-S24507 2.8m line cord | 39Y7919 | 6216 |
Taiwan 15A/125V C13/CNS 10917 2.8m line cord | 00CG267 | 6402 |
United Kingdom 10A/250V C13 to BS 1363/A 2.8m line cord | 39Y7923 | 6215 |
Physical specifications
The E1012 and E1024 have the following dimensions and weight (approximate):
- E1012
- Height: 87 mm (3.4 in.)
- Width: 447 mm (17.6 in.)
- Depth: 523 mm (20.6 in.)
- E1024
- Height: 89 mm (3.5 in.)
- Width: 447 mm (17.6 in.)
- Depth: 519 mm (20.5 in.)
- Weight
- E1012: Minimum: 16.8 kg (37.0 lb); Maximum: 26.6 kg (58.6 lb)
- E1024: Minimum: 16.9 kg (37.2 lb); Maximum: 23.4 kg (51.6 lb)
Operating environment
The E1012 and E1024 are supported in the following environment:
- Air temperature:
- Operating: 5 °C to 40 °C (41 °F to 104 °F); decrease the maximum ambient temperature by 3.3 °C for every 1,000 m (3,280 ft)
- Storage: -10 °C to +60 °C (14 °F to 140 °F)
- Maximum altitude: 3,000 m (9,842 ft)
- Humidity:
- Operating: 8% to 85% (non-condensing)
- Storage: 5% to 90% (non-condensing)
- Electrical:
- 100 to 240 (nominal) V AC; 50 Hz to 60 Hz
- BTU output: 1488 Btu/hr (436 W)
- Noise level: 6.8 bels
Warranty
The E1012 and E1024 have a three-year parts only warranty with 9x5/next business day (NBD) terms. Lenovo offers the service upgrades through warranty maintenance upgrades and post-warranty maintenance agreements with a well-defined scope of services, including service hours, response time, term of service, and service agreement terms and conditions.
Lenovo warranty service upgrade offerings are region-specific. Not all warranty service upgrades are available in every region. For more information about Lenovo warranty service upgrade offerings that are available in your region, go to the Lenovo Data Center Solution Configurator (DCSC):
http://dcsc.lenovo.com
The following table explains warranty service definitions for the E1012 and E1024 enclosures.
Term | Description |
On-site service | A service technician will arrive at the client location for equipment service. |
24x7x4 hour | A service technician is scheduled to arrive at the client location within four hours after remote problem determination is completed. Lenovo provides service around the clock, every day, including Lenovo holidays. |
9x5x4 hour | A service technician is scheduled to arrive at the client location within four business hours after remote problem determination is completed. Lenovo provides service 8:00 am - 5:00 pm in the client's local time zone, Monday-Friday, excluding Lenovo holidays. For example, if a customer reports an incident at 3:00 pm on Friday, the technician will arrive by 10:00 am the following Monday. |
9x5 next business day | A service technician is scheduled to arrive at the client location on the business day after remote problem determination is completed. Lenovo provides service 8:00 am - 5:00 pm in the client's local time zone, Monday - Friday, excluding Lenovo holidays. Calls received after 4:00 pm local time require an extra business day for service dispatch. Next business day service is not guaranteed. |
In general, the types of Lenovo warranty service upgrades for the E1012 and E1024 are as follows:
- Warranty and maintenance service upgrades:
- Onsite support for 9x5 NBD coverage
- 4-hour target response time with onsite, 9x5 or 24x7 service coverage
- Up to five years of warranty extension for all service levels in one or two year increments
- Hard Drive Retention
Lenovo's Hard Drive Retention service is a multi-drive hard drive retention offering that ensures your data is always under your control, regardless of the number of hard drives that are installed in your Lenovo system. In the unlikely event of a hard drive failure, you retain possession of your hard drive while Lenovo replaces the failed drive part. Your data stays safely on your premises, in your hands. The Hard Drive Retention service can be purchased in convenient bundles with our warranty upgrades and extensions.
Regulatory compliance
The E1012 and E1024 conform to the following regulations:
- UL 60950-1, 2nd Edition, 2007-03-27 (USA)
- CAN/CSA-C22.2 No 60950-1-07, 2nd Edition, 2007-03 (Canada)
- IEC 60950-1:2005 (2nd Edition); Am 1:2009
- EN 60950-1:2005, 2nd Edition, AM1 2009 (EU)
- CFR 47 Part 15 Subpart B Class A (USA FCC)
- ICES-003:2012, Class A (Canada)
- EN 55022: 2010 Class A (EU)
- EN 55024: 2010 (EU)
- ASNZS CISPR 22-2009 Class A
- CNS 14338 (2006)
- KN22 Class A
- VCCI Technical Requirements 2012 Class A
- RoHS Directive 2011/65/EU
- EAC
- NOM
- UL, BMSI, CCC
RAID controllers and HBAs
The E1012 and E1024 expansion enclosures are supported with the RAID adapters and HBAs that are listed in the following table.
Description | Part number | Max qty of enclosures per adapter |
|
Single I/O module |
Dual I/O module |
||
System x HBAs (non-RAID) | |||
6Gb SAS HBA | 46M0907 | 8 | No support |
System x RAID adapters | |||
ServeRAID M5225-2GB SAS/SATA Controller | 00AE938 | 8 | 4 |
ServeRAID M5120 SAS/SATA Controller | 81Y4478 | 8 | 4 |
ThinkServer RAID adapters | |||
ThinkServer 9286CV-8e 6Gb 8-port External SAS RAID Adapter by LSI | 4XB0F28699 | 8 | 4 |
ThinkServer 9286CV-8e 6Gb SAS RAID Adapter by LSI | 4XB0F28646 | 8 | 4 |
ThinkServer 9280-8e 6Gb 8-port RAID Adapter by LSI | 4XB0F28645 | 8 | 4 |
The following table summarizes features of supported RAID adapters.
Feature | M5225-2GB | M5120 | 9286CV-8e | 9280-8e |
Part number | 00AE938 | 81Y4478 | 4XB0F28646 4XB0F28699 |
4XB0F28645 |
Form factor | Low profile | Low profile | Low profile | Low profile |
Controller chip | LSI SAS3108 | LSI SAS2208 | LSI SAS2208 | LSI SAS2108 |
Host interface | PCIe 3.0 x8 | PCIe 3.0 x8 | PCIe 3.0 x8 | PCIe 2.0 x8 |
Port interface | 12 Gbps SAS | 6 Gbps SAS | 6 Gbps SAS | 6 Gbps SAS |
Number of external ports | 8 | 8 | 8 | 8 |
External port connectors | 2x Mini-SAS HD (SFF-8644) |
2x Mini-SAS (SFF-8088) |
2x Mini-SAS (SFF-8088) |
2x Mini-SAS (SFF-8088) |
Drive interface | SAS | SAS | SAS | SAS |
Drive type | HDD, SED, SSD | HDD, SED, SSD | HDD, SED, SSD | HDD, SED, SSD |
Max number of devices | 240 | 240 | 240 | 240 |
RAID levels | 0/1/10/5/50; Optional 6/60 (PN 47C8706) |
0/1/10/5/50; Optional 6/60 (PN 81Y4546) |
0/1/10/5/50/6/60 | 0/1/10/5/50/6/60 |
JBOD mode | No | No | No | No |
Cache | 2 GB (included) | 512 MB (PNs 81Y4484, 81Y4487) 1 GB (PN 81Y4559) 2 GB (PN 47C8670) |
1 GB (included) | 512 MB (included) |
Cache protection | Flash (included) | Battery (optional for 81Y4484; PN 81Y4508) Flash (included with 81Y4487, 81Y4559, 47C8670) |
Flash (included) | Battery (optional; PN 67Y2647) |
SSD Caching | Optional (PN 47C8712) |
Optional (PN 90Y4318) |
Optional (PN 4XB0F28702) |
No |
The 6Gb SAS HBA (part number 46M0907) has the following features and specifications:
- Form factor: Low profile
- Controller chip: LSI SAS2008
- Host interface: PCIe 2.0 x8
- Port interface: 6 Gbps SAS/3 Gbps SATA
- Number of ports: 8 (four external, four internal)
- Port connectors: 1x Mini-SAS x4 (SFF-8088), 4x SATA (internal)
- Drive interface: SAS
- Drive type: HDD, SSD
- Maximum number of devices: 512
- RAID levels: None, JBOD mode only
- Cache: None
Servers
The E1012 and E1024 expansion enclosures are supported with the following Lenovo servers:
- System x3100 M5 Type 5457
- System x3250 M5 Type 5458
- System x3300 M4 Type 7382
- System x3500 M4 Type 7383 (E5-2600 and E5-2600 v2)
- System x3500 M5 Type 5464
- System x3530 M4 Type 7160 (E5-2400 and E5-2400 v2)
- System x3550 M4 Type 7914 (E5-2600 and E5-2600 v2)
- System x3550 M5 Type 5463
- System x3550 M5 Type 8869
- System x3630 M4 Type 7158 (E5-2400 and E5-2400 v2)
- System x3650 M4 Type 7915 (E5-2600 and E5-2600 v2)
- System x3650 M4 BD Type 5466
- System x3650 M4 HD Type 5460
- System x3650 M5 Type 5462
- System x3650 M5 Type 8871
- System x3750 M4 Type 8753
- System x3850 X6 Type 6241 (E7 v2 and E7 v3)
- System x3950 X6 Type 6241 (E7 v2 and E7 v3)
- ThinkServer RS140
- ThinkServer RD350 (E5-2600 v3 and E5-2600 v4)
- ThinkServer RD450 (E5-2600 v3 and E5-2600 v4)
- ThinkServer RD550 (E5-2600 v3 and E5-2600 v4)
- ThinkServer RD650 (E5-2600 v3 and E5-2600 v4)
- ThinkServer TS440
- ThinkServer TS450
- ThinkServer TD350 (E5-2600 v3 and E5-2600 v4)
For RAID adapters and HBAs support details for a particular server, refer to a Lenovo Press product guide for the server, found at: http://lenovopress.com
Operating systems
The E1012 and E1024 expansion enclosures support the following operating systems that are supported by RAID adapters and HBAs listed in RAID adapters and HBAs.
- Microsoft
- Microsoft Windows Server 2012 R2
- Microsoft Windows Server 2012
- Microsoft Windows Server 2008 R2
- Red Hat
- Red Hat Enterprise Linux 7
- Red Hat Enterprise Linux 6 Server Edition
- Red Hat Enterprise Linux 6 Server x64 Edition
- Red Hat Enterprise Linux 5 Server Edition
- Red Hat Enterprise Linux 5 Server x64 Edition
- SUSE
- SUSE Linux Enterprise Server 12
- SUSE Linux Enterprise Server 11 for AMD64/EM64T
- SUSE Linux Enterprise Server 11 for x86
- SUSE Linux Enterprise Server 10 for AMD64/EM64T
- VMware
- VMware vSphere 6.0 (ESXi)
- VMware vSphere 5.5 (ESXi)
- VMware vSphere 5.1 (ESXi)
For information about operating compatibility with System x and ThinkServer systems, refer to the Operating System Interoperability Guide: http://lenovopress.com/osig
Rack cabinets
The following table lists the rack cabinets that are currently offered by Lenovo that can be used for mounting the E1012 and E1024 storage expansion enclosures and other IT infrastructure building blocks.
Description | Part number |
---|---|
25U S2 Standard Rack (1000 mm deep; 2 sidewall compartments) | 93072RX |
25U Static S2 Standard Rack (1000 mm deep; 2 sidewall compartments) | 93072PX |
42U S2 Standard Rack (1000 mm deep; 6 sidewall compartments) | 93074RX |
42U 1100mm Enterprise V2 Dynamic Rack (6 sidewall compartments) | 93634PX |
42U 1100mm Enterprise V2 Dynamic Expansion Rack (6 sidewall compartments) | 93634EX |
42U 1200mm Deep Dynamic Rack (6 sidewall compartments) | 93604PX |
42U 1200mm Deep Static Rack (6 sidewall compartments) | 93614PX |
42U Enterprise Rack (1105 mm deep; 4 sidewall compartments) | 93084PX |
42U Enterprise Expansion Rack (1105 mm deep; 4 sidewall compartments) | 93084EX |
For more information, see the list of Product Guides in the Rack cabinets category:
http://lenovopress.com/servers/options/racks#rt=product-guide
Power distribution units
The following table lists the power distribution units (PDUs) that are currently offered by Lenovo that can be used for distributing electrical power to the E1012 and E1024 storage expansion enclosures and other IT infrastructure building blocks mounted in a rack cabinet.
Description | Part number |
---|---|
0U Basic PDUs | |
0U 36 C13/6 C19 24A/200-240V 1 Phase PDU with NEMA L6-30P line cord | 00YJ776 |
0U 36 C13/6 C19 32A/200-240V 1 Phase PDU with IEC60309 332P6 line cord | 00YJ777 |
0U 21 C13/12 C19 32A/200-240V/346-415V 3 Phase PDU with IEC60309 532P6 line cord | 00YJ778 |
0U 21 C13/12 C19 48A/200-240V 3 Phase PDU with IEC60309 460P9 line cord | 00YJ779 |
Switched and Monitored PDUs | |
0U 20 C13/4 C19 Switched and Monitored 24A/200-240V/1Ph PDU w/ NEMA L6-30P line cord | 00YJ781 |
0U 20 C13/4 C19 Switched and Monitored 32A/200-240V/1Ph PDU w/ IEC60309 332P6 line cord | 00YJ780 |
0U 18 C13/6 C19 Switched / Monitored 32A/200-240V/346-415V/3Ph PDU w/ IEC60309 532P6 cord | 00YJ782 |
0U 12 C13/12 C19 Switched and Monitored 48A/200-240V/3Ph PDU w/ IEC60309 460P9 line cord | 00YJ783 |
1U 9 C19/3 C13 Switched and Monitored DPI PDU (without line cord) | 46M4002 |
1U 9 C19/3 C13 Switched and Monitored 60A 3Ph PDU with IEC 309 3P+Gnd cord | 46M4003 |
1U 12 C13 Switched and Monitored DPI PDU (without line cord) | 46M4004 |
1U 12 C13 Switched and Monitored 60A 3 Phase PDU with IEC 309 3P+Gnd line cord | 46M4005 |
Ultra Density Enterprise PDUs (9x IEC 320 C13 + 3x IEC 320 C19 outlets) | |
Ultra Density Enterprise C19/C13 PDU Module (without line cord) | 71762NX |
Ultra Density Enterprise C19/C13 PDU 60A/208V/3ph with IEC 309 3P+Gnd line cord | 71763NU |
C13 Enterprise PDUs (12x IEC 320 C13 outlets) | |
DPI C13 Enterprise PDU+ (without line cord) | 39M2816 |
DPI Single Phase C13 Enterprise PDU (without line cord) | 39Y8941 |
C19 Enterprise PDUs (6x IEC 320 C19 outlets) | |
DPI Single Phase C19 Enterprise PDU (without line cord) | 39Y8948 |
DPI 60A 3 Phase C19 Enterprise PDU with IEC 309 3P+G (208 V) fixed line cord | 39Y8923 |
Front-end PDUs (3x IEC 320 C19 outlets) | |
DPI 30amp/125V Front-end PDU with NEMA L5-30P line cord | 39Y8938 |
DPI 30amp/250V Front-end PDU with NEMA L6-30P line cord | 39Y8939 |
DPI 32amp/250V Front-end PDU with IEC 309 2P+Gnd line cord | 39Y8934 |
DPI 60amp/250V Front-end PDU with IEC 309 2P+Gnd line cord | 39Y8940 |
DPI 63amp/250V Front-end PDU with IEC 309 2P+Gnd line cord | 39Y8935 |
Universal PDUs (7x IEC 320 C13 outlets) | |
DPI Universal 7 C13 PDU (with 2 m IEC 320-C19 to C20 rack power cord) | 00YE443 |
NEMA PDUs (6x NEMA 5-15R outlets) | |
DPI 100-127V PDU with fixed NEMA L5-15P line cord | 39Y8905 |
Line cords for PDUs that ship without a line cord | |
DPI 30a Line Cord (NEMA L6-30P) | 40K9614 |
DPI 32a Line Cord (IEC 309 P+N+G) | 40K9612 |
DPI 32a Line Cord (IEC 309 3P+N+G) | 40K9611 |
DPI 60a Cord (IEC 309 2P+G) | 40K9615 |
DPI 63a Cord (IEC 309 P+N+G) | 40K9613 |
DPI Australian/NZ 3112 Line Cord (32A) | 40K9617 |
DPI Korean 8305 Line Cord (30A) | 40K9618 |
For more information, see the list of Product Guides in the PDU category:
https://lenovopress.com/servers/options/pdu
Uninterruptible power supply units
The following table lists the uninterruptible power supply (UPS) units that are currently offered by Lenovo that can be used for providing electrical power protection to the E1012 and E1024 storage expansion enclosures and other IT infrastructure building blocks.
Description | Part number |
---|---|
Worldwide models | |
RT1.5kVA 2U Rack or Tower UPS (100-125VAC) (8x NEMA 5-15R 12A outlets) | 55941AX |
RT1.5kVA 2U Rack or Tower UPS (200-240VAC) (8x IEC 320 C13 10A outlets) | 55941KX |
RT2.2kVA 2U Rack or Tower UPS (100-125VAC) (8x NEMA 5-20R 16A outlets) | 55942AX |
RT2.2kVA 2U Rack or Tower UPS (200-240VAC) (8x IEC 320 C13 10A, 1x IEC 320 C19 16A outlets) | 55942KX |
RT3kVA 2U Rack or Tower UPS (100-125VAC) (6x NEMA 5-20R 16A, 1x NEMA L5-30R 24A outlets) | 55943AX |
RT3kVA 2U Rack or Tower UPS (200-240VAC) (8x IEC 320 C13 10A, 1x IEC 320 C19 16A outlets) | 55943KX |
RT5kVA 3U Rack or Tower UPS (200-240VAC) (8x IEC 320 C13 10A, 2x IEC 320 C19 16A outlets) | 55945KX |
RT6kVA 3U Rack or Tower UPS (200-240VAC) (8x IEC 320 C13 10A, 2x IEC 320 C19 16A outlets) | 55946KX |
RT8kVA 6U Rack or Tower UPS (200-240VAC) (4x IEC 320-C19 16A outlets) | 55948KX |
RT11kVA 6U Rack or Tower UPS (200-240VAC) (4x IEC 320-C19 16A outlets) | 55949KX |
RT8kVA 6U 3:1 Phase Rack or Tower UPS (380-415VAC) (4x IEC 320-C19 16A outlets) | 55948PX |
RT11kVA 6U 3:1 Phase Rack or Tower UPS (380-415VAC) (4x IEC 320-C19 16A outlets) | 55949PX |
ASEAN, HTK, INDIA, and PRC models | |
ThinkSystem RT3kVA 2U Standard UPS (200-230VAC) (2x C13 10A, 2x GB 10A, 1x C19 16A outlets) | 55943KT |
ThinkSystem RT3kVA 2U Long Backup UPS (200-230VAC) (2x C13 10A, 2x GB 10A, 1x C19 16A outlets) | 55943LT |
ThinkSystem RT6kVA 5U UPS (200-230VAC) (2x C13 10A outlets, 1x Terminal Block output) | 55946KT |
ThinkSystem RT10kVA 5U UPS (200-230VAC) (2x C13 10A outlets, 1x Terminal Block output) | 5594XKT |
For more information, see the list of Product Guides in the Uninterruptible Power Supply Units category:
http://lenovopress.com/servers/options/ups#rt=product-guide
Lenovo Financial Services
Lenovo Financial Services reinforces Lenovo’s commitment to deliver pioneering products and services that are recognized for their quality, excellence, and trustworthiness. Lenovo Financial Services offers financing solutions and services that complement your technology solution anywhere in the world.
We are dedicated to delivering a positive finance experience for customers like you who want to maximize your purchase power by obtaining the technology you need today, protect against technology obsolescence, and preserve your capital for other uses.
We work with businesses, non-profit organizations, governments and educational institutions to finance their entire technology solution. We focus on making it easy to do business with us. Our highly experienced team of finance professionals operates in a work culture that emphasizes the importance of providing outstanding customer service. Our systems, processes and flexible policies support our goal of providing customers with a positive experience.
We finance your entire solution. Unlike others, we allow you to bundle everything you need from hardware and software to service contracts, installation costs, training fees, and sales tax. If you decide weeks or months later to add to your solution, we can consolidate everything into a single invoice.
Our Premier Client services provide large accounts with special handling services to ensure these complex transactions are serviced properly. As a premier client, you have a dedicated finance specialist who manages your account through its life, from first invoice through asset return or purchase. This specialist develops an in-depth understanding of your invoice and payment requirements. For you, this dedication provides a high-quality, easy, and positive financing experience.
For your region specific offers please ask your Lenovo sales representative or your technology provider about the use of Lenovo Financial Services. For more information, see the following Lenovo website:
http://www.lenovo.com/us/en/landingpage/lenovo-financial-services
Related product families
Product families related to this document are the following:
Trademarks
Lenovo and the Lenovo logo are trademarks or registered trademarks of Lenovo in the United States, other countries, or both. A current list of Lenovo trademarks is available on the Web at https://www.lenovo.com/us/en/legal/copytrade/.
The following terms are trademarks of Lenovo in the United States, other countries, or both:
Lenovo®
System x®
ThinkServer®
ThinkSystem®
The following terms are trademarks of other companies:
Linux® is the trademark of Linus Torvalds in the U.S. and other countries.
Microsoft®, Windows Server®, and Windows® are trademarks of Microsoft Corporation in the United States, other countries, or both.
Other company, product, or service names may be trademarks or service marks of others.