Abstract
The Lenovo ThinkSystem SR850 is a 4-socket server that features a streamlined 2U rack design, optimized for price and performance, with best-in-class flexibility and expandability.
This product guide provides essential pre-sales information to understand the ThinkSystem SR850 server, its key features and specifications, components and options, and configuration guidelines. This guide is intended for technical specialists, sales specialists, sales engineers, IT architects, and other IT professionals who want to learn more about the SR850 and consider its use in IT solutions.
Withdrawn: The ThinkSystem SR850 with 1st Generation Intel Xeon Scalable processors is now withdrawn from marketing. For the SR850 with 2nd Generation processors, see the the following product guide:
- SR850 (Xeon SP Gen 2)
https://lenovopress.com/lp1052
Change History
Changes in the February 2, 2021 update:
- The ThinkSystem SR850 with 1st Generation Intel Xeon Scalable processors is now withdrawn from marketing.
Walkthrough Video with David Watts and Tisha Jefferson
Introduction
The Lenovo ThinkSystem SR850 is a 4-socket server that features a streamlined 2U rack design that is optimized for price and performance, with best-in-class flexibility and expandability. Models of the SR850 are powered by up to four Intel Xeon Processor Scalable Family processors, each with up to 28 cores, for an efficient 4-socket solution. The ThinkSystem SR850’s agile design provides rapid upgrades for processors and memory, and its large, flexible storage capacity helps to keep pace with data growth.
Suggested uses: General business consolidation, data analytics, virtualization, database, dense computing and scientific applications
Figure 1. Lenovo ThinkSystem SR850
Did you know?
With a dense 2U design, the Lenovo ThinkSystem SR850 provides advanced features and capabilities. These include support for up to four sockets and 48 DIMMs, mix and match internal storage, and enterprise-grade systems management with the embedded Lenovo XClarity Controller.
The SR850 has space for 16x 2.5-inch drive bays, up to 8 of which can be configured as AnyBay drives - supporting SAS, SATA or NVMe drives. NVMe drives are high-speed, low-latency storage, ideal for storage tiering. The server also offers easy expansion, with up to nine PCIe slots (two of which are x16) and up to 2 (mirrored) M.2 drives for rapid OS boot, faster than either USB keys or SD cards.
Key features
The flexible ThinkSystem SR850 server can scale from two to four Intel Xeon Gold or Platinum processors, delivering significantly faster performance than the previous generation. Built for standard workloads like general business applications and server consolidation, it can also accommodate high-growth areas such as databases and virtualization. The ThinkSystem SR850’s agile design permits rapid upgrades for processors and memory, and its large, flexible storage capacity helps to keep pace with data growth.
With the capability to support up to 48 DIMMs, four sockets, mix-and-match internal storage with up to 16 drives, and a dedicated slot for Gigabit or 10 GbE networking, the SR850 provides unmatched features and capabilities in a dense 2U rack-mount design.
Scalability and performance
The SR850 offers numerous features to boost performance, improve scalability and reduce costs:
- Supports Gold and Platinum level processors in the Intel Xeon Processor Scalable Family. Processors supported have up to 28 cores, core speeds of up to 3.6GHz, L3 cache sizes up to 38.5 MB, and TDP ratings of up to 205W.
- The SR850's processor mezzanine tray design enables you to start with two processors and 24 DIMM sockets and upgrade to four processors and 48 DIMM sockets when you need it, helping lower initial costs and manage growth.
- Up to four processors, 112 cores, and 226 threads maximize the concurrent execution of multithreaded applications.
- Intelligent and adaptive system performance with Intel Turbo Boost Technology 2.0 allows processor cores to run at maximum speeds during peak workloads by temporarily going beyond processor TDP.
- Intel Hyper-Threading Technology boosts performance for multithreaded applications by enabling simultaneous multithreading within each processor core, up to two threads per core.
- Intel Virtualization Technology integrates hardware-level virtualization hooks that allow operating system vendors to better use the hardware for virtualization workloads.
- Support for up to 48 TruDDR4 memory DIMMs operating at 2666 MHz means you have the fastest available memory subsystem and memory capacity of up to 3.0 TB using 48x 64 GB LRDIMMs (all processors) or 6.0 TB using 48x 128 GB 3DS RDIMMs (requires M-suffix processors).
- The use of solid-state drives (SSDs) instead of, or along with, traditional spinning drives (HDDs), can improve I/O performance. An SSD can support up to 100 times more I/O operations per second (IOPS) than a typical HDD.
- Up to 16x 2.5-inch drive bays -- supporting combinations of SAS or SATA HDDs, SAS or SATA SSDs, and NVMe PCIe SSDs -- provide a flexible and scalable all-in-one platform to meet your increasing demands.
- Support for up to 8x NVMe PCIe SSDs in a 2.5-inch form factor maximizes drive I/O performance, in terms of throughput, bandwidth, and latency.
- New high-speed RAID controllers from Broadcom provide 12 Gb SAS connectivity to the drive backplanes. A variety of RAID adapters are available, with cache up to 4 GB and support for 16 drives on a single controller.
- Supports a new Lenovo patented-design M.2 adapter for convenient operating system boot functions. Available M.2 adapters support either one M.2 drive or two M.2 drives in a RAID 1 configuration for boot drive performance and reliability.
- The server has a dedicated flexible LAN-on-motherboard (LOM) slot, supporting a variety of 10 GbE or Gigabit Ethernet adapters that do not occupy one of the standard PCIe slots.
- A total of up to 9 general-purpose PCIe 3.0 slots plus slots dedicated to the LOM adapter and the M.2 adapter.
- The server offers PCI Express 3.0 I/O expansion capabilities that improve the theoretical maximum bandwidth by almost 100% (8 GTps per link using 128b/130b encoding) compared to the previous generation of PCI Express 2.0 (5 GTps per link using 8b/10b encoding).
Availability and serviceability
The SR850 provides many features to simplify serviceability and increase system uptime:
- The server offers Single Device Data Correction (SDDC, also known as Chipkill), Adaptive Double- Device Data Correction (ADDDC, also known as Redundant Bit Steering or RBS), memory mirroring, and memory rank sparing for redundancy in the event of a non-correctable memory failure.
- The server offers hot-swap drives, supporting RAID redundancy for data protection and greater system uptime.
- The Dual M.2 Boot Adapter supports RAID-1 which enables two installed M.2 drives to be configured as a redundant pair.
- The server has up to two hot-swap redundant power supplies and six hot-swap redundant fans to provide availability for business-critical applications.
- The power-source-independent light path diagnostics uses LEDs to lead the technician to failed (or failing) components, which simplifies servicing, speeds up problem resolution, and helps improve system availability.
- The optional LCD system information display panel provides more detailed diagnostics by displaying all error messages and VPD data needed for a service call, thereby aiding with problem resolution and system uptime.
- Proactive Platform Alerts (including PFA and SMART alerts): Processors, voltage regulators, memory, internal storage (SAS/SATA HDDs and SSDs, NVMe SSDs, M.2 storage, flash storage adapters), fans, power supplies, RAID controllers, server ambient and subcomponent temperatures. Alerts can be surfaced through the XClarity Controller to managers such as Lenovo XClarity Administrator, VMware vCenter, and Microsoft System Center. These proactive alerts let you take appropriate actions in advance of possible failure, thereby increasing server uptime and application availability.
- Solid-state drives (SSDs) offer more reliability than traditional mechanical HDDs for greater uptime.
- The built-in XClarity Controller continuously monitors system parameters, triggers alerts, and performs recovery actions in case of failures to minimize downtime.
- Built-in diagnostics in UEFI, using Lenovo XClarity Provisioning Manager, speed up troubleshooting tasks to reduce service time.
- Lenovo XClarity Provisioning Manager collects and saves service data to USB key drive or remote CIFS share folder, for troubleshooting and to reduce service time.
- Auto restart in the event of a momentary loss of AC power (based on the power policy setting in the XClarity Controller service processor)
- Support for the XClarity Administrator Mobile app running on a supported smartphone and connected to the server through the service-enabled USB port, enables additional local systems management functions.
- Three-year or one-year customer-replaceable unit and onsite limited warranty, 9 x 5 next business day. Optional service upgrades are available.
Manageability and security
Powerful systems management features simplify local and remote management of the SR850:
- Lenovo XClarity Controller (XCC) monitors server availability and performs remote management. XCC Advanced is standard, which enables remote KVM. Optional XCC Enterprise enables the mounting of remote media files (ISO and IMG image files), boot capture, and power capping.
- Lenovo XClarity Administrator offers comprehensive hardware management tools that help to increase uptime, reduce costs and improve productivity through advanced server management capabilities.
- New UEFI-based Lenovo XClarity Provisioning Manager, accessible from F1 during boot, provides system inventory information, graphical UEFI Setup, platform update function, RAID Setup wizard, operating system installation function, and diagnostic functions.
- Support for Lenovo XClarity Energy Manager, which captures real-time power and temperature data from the server and provides automated controls to lower energy costs.
- Integrated Trusted Platform Module (TPM) 2.0 support enables advanced cryptographic methods, such as digital signatures and remote attestation.
- Supports Secure Boot to ensure only a digitally signed operating system can be used. Supported with HDDs and SSDs, as well as M.2 drives in the M.2 Adapter.
- Industry-standard Advanced Encryption Standard (AES) NI support for faster, stronger encryption.
- Intel Execute Disable Bit functionality can prevent certain classes of malicious buffer overflow attacks when combined with a supported operating system.
- Intel Trusted Execution Technology provides enhanced security through hardware-based resistance to malicious software attacks, allowing an application to run in its own isolated space, protected from all other software running on a system.
Energy efficiency
The SR850 offers the following energy-efficiency features to save energy, reduce operational costs, and increase energy availability:
- Energy-efficient planar components help lower operational costs.
- High-efficiency power supplies with 80 PLUS Platinum certifications
- Intel Intelligent Power Capability turns individual processor elements on and off as needed to reduce power draw.
- Low-voltage 1.2 V DDR4 memory offers energy savings compared to 1.35 V and 1.5 V DDR3 DIMMs.
- Solid-state drives (SSDs) consume as much as 80% less power than traditional spinning 2.5-inch HDDs.
- The server uses hexagonal ventilation holes, which can be grouped more densely than round holes, providing more efficient airflow through the system and thus keeping your system cooler.
- Optional Lenovo XClarity Energy Manager provides advanced data center power notification, analysis, and policy-based management to help achieve lower heat output and reduced cooling needs.
Components and connectors
The following figure shows the front of the server.
Figure 2. Front view of the Lenovo ThinkSystem SR850
The following figure shows the rear of the server.
Figure 3. Rear view of the Lenovo ThinkSystem SR850
The following figure shows the locations of key components inside the server.
Figure 4. Internal view of the Lenovo ThinkSystem SR850
System architecture
The following figure shows the architectural block diagram of the SR850, showing the major components and their connections.
Figure 5. SR850 architectural block diagram
Standard specifications
The following table lists the standard specifications.
Components | Specification |
---|---|
Machine types | 7X18 - 1 year warranty 7X19 - 3 year warranty |
Form factor | 2U rack. |
Processor | Up to four Intel Xeon Processor Scalable Family of processors, either Gold or Platinum level processors (formerly codename "Skylake"). Supports processors up to 28 cores, core speeds up to 3.6 GHz, and TDP ratings up to 205W. Two processor sockets on the system board and two processors on the Processor and Memory Expansion Tray (standard on most models). Two Intel Ultra Path Interconnect (UPI) links at 10.4 GT/s each. Four processors are connected in a ring topology. |
Chipset | Intel C624 "Lewisburg" chipset |
Memory | Up to 48 DIMM sockets (12 DIMMs per processor) supporting Lenovo TruDDR4 DIMMs at up to 2666 MHz. RDIMMs, LRDIMMs and 3DS RDIMMs are supported, but memory types cannot be mixed. There are 24 DIMM sockets on the system board, and an additional 24 DIMM sockets on the processor and memory expansion tray (standard on most models). |
Memory maximums | With RDIMMs: Up to 1.5 TB with 48x 32 GB RDIMMs and four processors. With LRDIMMs: Up to 3.0 TB with 48x 64 GB LRDIMMs and four processors. With 3DS RDIMMs: Up to 6.0 TB with 48x 128 GB 3DS RDIMMs and four processors (requires M-suffix processors that support greater than 786 GB memory per processor) |
Memory protection | ECC, SDDC (for x4-based memory DIMMs), ADDDC (for x4-based memory DIMMs), memory mirroring, and memory sparing. |
Disk drive bays | Up to 16 2.5-inch hot-swap SAS/SATA bays. |
Maximum internal storage |
|
Storage controller |
|
Optical drive bays | No internal optical drive. |
Tape drive bays | No internal backup drive. |
Network interfaces | Integrated 10Gb Ethernet controller, based on the Intel Ethernet Connection X722. The server supports 1 of 6 available Phy adapters, providing either 2- or 4-port Gigabit Ethernet, 2- or 4-port 10 GbE with SFP+ connections or 2- or 4-port 10 GbE with RJ45 connections. One port can optionally be shared with the XClarity Controller (XCC) management processor for Wake-on-LAN and NC-SI support. |
PCI Expansion slots |
Up to 9 PCIe slots plus a slot reserved for a LOM Ethernet adapter, plus a slot for the M.2 adapter. Six slots plus the LOM slot are on the system board and three (slots 3-5) are through a riser card. Three riser cards are available. All slots are available with two processors. The slots are as follows:
|
Ports |
Front: Two USB 2.0 ports or one USB 2.0 and one USB 3.0 port, model dependent. The first USB 2.0 port can be configured to support local systems management by using the XClarity Administrator mobile app on a mobile device connected via a USB cable. Optional front VGA video port (CTO or field upgrade). Rear: Two USB 3.0 ports, one VGA video port, one DB-9 serial port, and one RJ-45 XClarity Controller (XCC) systems management port. The serial port can be shared with the XCC for serial redirection functions. Internal: Optional M.2 adapter in dedicated slot supporting one or two M.2 drives (for OS boot support, including hypervisor support). |
Cooling | Six N+1 redundant hot swap 60 mm fans (all six standard). One fan integrated in each power supply. |
Power supply | Up to two hot-swap redundant AC power supplies (all 80 PLUS Platinum certification): 750 W, 1100 W and 1600 W AC options, supporting 220 V AC. 750 W and 1100 W options also support 110V input supply. In China only, all power supply options support 240 V DC. Second power supply requires either Processor and Memory Expansion Tray or a power interposer card. |
Video | G200 graphics with 16 MB memory with 2D hardware accelerator, integrated into the XClarity Controller. Maximum resolution is 1920x1200 32bpp at 60Hz. |
Hot-swap parts | Drives, power supplies, and fans. |
Systems management | XClarity Controller embedded management, XClarity Administrator centralized infrastructure delivery, XClarity Integrator plugins, and XClarity Energy Manager centralized server power management. XClarity Controller Advanced standard with the SR850; XClarity Controller Enterprise optional with software license upgrade. Light path diagnostics for local failure detection and reporting, with optional LCD diagnostics pull-out panel. |
Security features | Power-on password, administrator's password, Trusted Platform Module (TPM), supporting TPM 1.2 or TPM 2.0. In China only, optional Trusted Cryptographic Module (TCM). Lockable top cover. Optional lockable front security bezel. |
Operating systems supported | Microsoft Windows Server, Red Hat Enterprise Linux, SUSE Linux Enterprise Server, VMware ESXi. See the Operating system support section for specifics. |
Limited warranty | Three-year or one-year (model dependent) customer-replaceable unit and onsite limited warranty with 9x5 next business day (NBD). |
Service and support | Optional service upgrades are available through Lenovo Services: 4-hour or 2-hour response time, 6-hour fix time, 1-year or 2-year warranty extension, software support for Lenovo hardware and some third-party applications. |
Dimensions | Width: 445 mm (17.5 in.), height: 87 mm (3.4 in.), depth: 765 mm (30.1 in.). See Physical and electrical specifications for details. |
Weight | Minimum configuration: 18 kg (40 lb.), maximum: 27 kg (59.6 lb) |
The SR850 servers are shipped with the following items:
- ThinkSystem Toolless Slide Rail
- Documentation flyer
- Power cords (model and region dependent)
Models
ThinkSystem SR850 models can be configured by using the Lenovo Data Center Solution Configurator (DCSC).
Configure-to-order (CTO) models are used to create models with factory-integrated server customizations. For CTO models, two types of base CTO models are available for the SR850 as listed in the columns in the following table:
- General purpose base CTO models are for general business (non-HPC) and is selectable by choosing General Purpose mode in DCSC.
- AI and HPC base models are intended for Artificial Intelligence (AI) and High Performance Computing (HPC) configurations and solutions are enabled using the AI & HPC Hardware - ThinkSystem Hardware mode in DCSC. These configurations, along with Lenovo EveryScale Solutions, can also be built using System x and Cluster Solutions Configurator (x-config). Tip: Some HPC and AI models are not listed in DCSC and can only be configured in x-config.
Preconfigured server models may also be available for the SR850, however these are region-specific; that is, each region may define their own server models, and not all server models are available in every region.
The following table lists the base CTO models of the ThinkSystem SR850 server.
Machine Type/Model General purpose |
Machine Type/Model for AI and HPC |
Description |
---|---|---|
7X19CTO1WW | 7X19CTOLWW | ThinkSystem SR850 – 3-year warranty |
7X18CTO1WW | 7X18CTOLWW | ThinkSystem SR850 – 1-year warranty |
The following tables list the available models, grouped by region.
- Models for Australia and New Zealand
- Models for South East Asian regions (ASEAN)
- Models for EMEA regions
- Models for Hong Kong, Taiwan, Korea (HTK)
- Models for India
- Models for Japan
- Models for Latin American regions (except Brazil)
- Models for USA and Canada
Models for Australia and New Zealand
All models have the following common features:
- No included drives (open drive bays)
- XCC Advanced with an available upgrade to XCC Enterprise
- No power cords included; ensure desired power cords are added to the order
- Slide Rail Kit (cable management arm is available but not included)
Model | Intel Xeon processors† |
Memory | RAID | Drive bays | Ethernet LOM |
Slots | Power supplies |
Front USB 3.0 |
LCD panel |
Front VGA |
---|---|---|---|---|---|---|---|---|---|---|
7X19A003AU | 2x Gold 5115 10C 85W 2.4GHz | 2x 8GB | RAID 530-8i | 8x 2.5" SAS / 16 | 4x1Gb | 8 / 11 | 1x 750W HS | No | No | Option |
7X19A009AU | 2x Gold 5115 10C 85W 2.4GHz | 2x 16GB | RAID 930-8i | 8x 2.5" SAS / 16 | 4x1Gb | 8 / 11 | 1x 750W HS | No | No | Option |
7X19A025AU | 2x Gold 5118 12C 105W 2.3GHz | 2x 16GB | RAID 530-8i | 8x 2.5" SAS / 16 | 4x1Gb | 8 / 11 | 1x 750W HS | No | No | Option |
7X19A029AU | 2x Gold 5118 12C 105W 2.3GHz | 2x 16GB | RAID 930-8i | 8x 2.5" SAS / 16 | 4x1Gb | 8 / 11 | 1x 750W HS | No | No | Option |
7X19A01GAU | 2x Gold 5120 14C 105W 2.2GHz | 2x 16GB | RAID 930-8i | 8x 2.5" SAS / 16 | 4x1Gb | 8 / 11 | 1x 750W HS | Yes | Yes | Option |
7X19A00DAU | 2x Gold 6134 8C 130W 3.2GHz | 2x 16GB | RAID 930-8i | 8x 2.5" SAS / 16 | 4x1Gb | 8 / 11 | 1x 1100W HS | Yes | Yes | Option |
7X19A010AU | 2x Gold 6136 12C 150W 3.0GHz | 2x 16GB | RAID 930-8i | 8x 2.5" SAS / 16 | 4x1Gb | 8 / 11 | 1x 1100W HS | Yes | Yes | Option |
7X19A01VAU | 2x Gold 6138 20C 125W 2.0GHz | 2x 16GB | RAID 930-8i | 8x 2.5" SAS / 16 | 4x1Gb | 8 / 11 | 1x 1100W HS | Yes | Yes | Option |
7X19A01MAU | 2x Gold 6140 18C 140W 2.3GHz | 2x 16GB | RAID 930-8i | 8x 2.5" SAS / 16 | 4x1Gb | 8 / 11 | 1x 1100W HS | Yes | Yes | Option |
7X19A00NAU | 2x Gold 6142 16C 150W 2.6GHz | 2x 16GB | RAID 930-8i | 8x 2.5" SAS / 16 | 4x1Gb | 8 / 11 | 1x 1100W HS | Yes | Yes | Option |
7X19A02CAU | 2x Gold 6152 22C 140W 2.1GHz | 2x 16GB | RAID 930-8i | 8x 2.5" SAS / 16 | 4x1Gb | 8 / 11 | 1x 1100W HS | Yes | Yes | Option |
7X19A01AAU | 2x Platinum 8153 16C 125W 2.0GHz | 2x 16GB | RAID 930-8i | 8x 2.5" SAS / 16 | 4x1Gb | 8 / 11 | 1x 1100W HS | Yes | Yes | Option |
7X19A01DAU | 2x Platinum 8160 24C 150W 2.1GHz | 2x 16GB | RAID 930-8i | 8x 2.5" SAS / 16 | 4x1Gb | 8 / 11 | 1x 1100W HS | Yes | Yes | Option |
7X19A01ZAU | 2x Platinum 8164 26C 150W 2.0GHz | 2x 16GB | RAID 930-8i | 8x 2.5" SAS / 16 | 4x1Gb | 8 / 11 | 1x 1100W HS | Yes | Yes | Option |
7X19A00PAU | 2x Platinum 8170 26C 165W 2.1GHz | 2x 16GB | RAID 930-8i | 8x 2.5" SAS / 16 | 4x1Gb | 8 / 11 | 1x 1600W HS | Yes | Yes | Option |
7X19A00MAU | 2x Platinum 8176 28C 165W 2.1GHz | 2x 16GB | RAID 930-8i | 8x 2.5" SAS / 16 | 4x1Gb | 8 / 11 | 1x 1600W HS | Yes | Yes | Option |
† Processor detail: Quantity, model, core count, TDP, core frequency
Models for South East Asian regions (ASEAN)
All models have the following common features:
- No included drives (open drive bays)
- XCC Advanced with an available upgrade to XCC Enterprise
- VGA port on the front of the server
- Pull-out LCD Display Panel
- USB 3.0 port on the front of the server
- No power cords included; ensure desired power cords are added to the order
- Slide Rail Kit (cable management arm is available but not included)
Model | Intel Xeon processors† |
Memory | RAID | Drive bays | Ethernet LOM |
Slots | Power supplies |
---|---|---|---|---|---|---|---|
7X19A00GSG | 2x Gold 5115 10C 85W 2.4GHz | 2x 16GB 2Rx8 | RAID 530-8i | 8x 2.5" SAS / 16 | 4x10Gb RJ45 | 11 / 11 | 1x 1100W HS |
7X19A00QSG | 2x Gold 5118 12C 105W 2.3GHz | 2x 16GB 2Rx8 | RAID 530-8i | 8x 2.5" SAS / 16 | 4x10Gb RJ45 | 11 / 11 | 1x 1100W HS |
7X19A012SG | 2x Gold 5120 14C 105W 2.2GHz | 2x 16GB 2Rx8 | RAID 530-8i | 8x 2.5" SAS / 16 | 4x10Gb RJ45 | 11 / 11 | 1x 1100W HS |
7X19A02BSG | 2x Gold 6126 12C 125W 2.6GHz | 2x 16GB 2Rx8 | RAID 530-8i | 8x 2.5" SAS / 16 | 4x10Gb RJ45 | 11 / 11 | 1x 1100W HS |
7X19A00XSG | 2x Gold 6130 16C 125W 2.1GHz | 2x 32GB | RAID 530-8i | 8x 2.5" SAS / 16 | 4x10Gb RJ45 | 11 / 11 | 1x 1100W HS |
7X19A017SG | 2x Gold 6134 8C 130W 3.2GHz | 2x 16GB 2Rx8 | RAID 530-8i | 8x 2.5" SAS / 16 | 4x10Gb RJ45 | 11 / 11 | 1x 1100W HS |
7X19A00VSG | 2x Gold 6140 18C 140W 2.3GHz | 2x 32GB | RAID 530-8i | 8x 2.5" SAS / 16 | 4x10Gb RJ45 | 11 / 11 | 1x 1600W HS |
7X19A01JSG | 2x Gold 6148 20C 150W 2.4GHz | 2x 32GB | RAID 530-8i | 8x 2.5" SAS / 16 | 4x10Gb RJ45 | 11 / 11 | 1x 1600W HS |
7X19A01BSG | 2x Gold 6152 22C 140W 2.1GHz | 2x 32GB | RAID 530-8i | 8x 2.5" SAS / 16 | 4x10Gb RJ45 | 11 / 11 | 1x 1600W HS |
† Processor detail: Quantity, model, core count, TDP, core frequency
Models for EMEA regions
All models have the following common features:
- No included drives (open drive bays)
- XCC Advanced with an available upgrade to XCC Enterprise
- Pull-out LCD Display Panel
- No power cords included; ensure desired power cords are added to the order
- Slide Rail Kit (cable management arm is available but not included)
Model | Intel Xeon processors† |
Memory | RAID | Drive bays | Ethernet LOM |
Slots | Power supplies |
Front USB 3.0 |
Front VGA |
---|---|---|---|---|---|---|---|---|---|
7X19A02GEA | 4x Gold 5115 10C 85W 2.4GHz | 4x 32GB | RAID 930-8i | 8x 2.5" / 16 (4x AnyBay) | Open | 11 / 11 | 2x 1100W HS | Yes | Yes |
7X19A02HEA | 4x Gold 5118 12C 105W 2.3GHz | 4x 32GB | RAID 930-8i | 8x 2.5" / 16 (4x AnyBay) | Open | 11 / 11 | 2x 1100W HS | Yes | Yes |
7X19A02JEA | 4x Gold 5120 14C 105W 2.2GHz | 4x 32GB | RAID 930-8i | 8x 2.5" / 16 (4x AnyBay) | Open | 11 / 11 | 2x 1100W HS | Yes | Yes |
7X19A02KEA | 4x Gold 6126 12C 125W 2.6GHz | 4x 32GB | RAID 930-8i | 8x 2.5" / 16 (4x AnyBay) | Open | 11 / 11 | 2x 1100W HS | Yes | Yes |
7X19A02LEA | 4x Gold 6130 16C 125W 2.1GHz | 4x 32GB | RAID 930-8i | 8x 2.5" / 16 (4x AnyBay) | Open | 11 / 11 | 2x 1100W HS | Yes | Yes |
7X19A02MEA | 4x Gold 6138 20C 125W 2.0GHz | 4x 32GB | RAID 930-8i | 8x 2.5" / 16 (4x AnyBay) | Open | 11 / 11 | 2x 1100W HS | Yes | Yes |
7X19A02NEA | 4x Gold 6148 20C 150W 2.4GHz | 4x 32GB | RAID 930-8i | 8x 2.5" / 16 (4x AnyBay) | Open | 11 / 11 | 2x 1600W HS | Yes | Yes |
7X19A02PEA | 4x Gold 6150 18C 165W 2.7GHz | 4x 32GB | RAID 930-8i | 8x 2.5" / 16 (4x AnyBay) | Open | 11 / 11 | 2x 1600W HS | Yes | Yes |
7X19A02QEA | 4x Gold 6152 22C 140W 2.1GHz | 4x 32GB | RAID 930-8i | 8x 2.5" / 16 (4x AnyBay) | Open | 11 / 11 | 2x 1600W HS | Yes | Yes |
7X19A02REA | 4x Platinum 8160 24C 150W 2.1GHz | 4x 32GB | RAID 930-8i | 8x 2.5" / 16 (4x AnyBay) | Open | 11 / 11 | 2x 1600W HS | Yes | Yes |
7X19A02SEA | 4x Platinum 8164 26C 150W 2.0GHz | 4x 32GB | RAID 930-8i | 8x 2.5" / 16 (4x AnyBay) | Open | 11 / 11 | 2x 1600W HS | Yes | Yes |
7X19A02TEA | 4x Platinum 8170 26C 165W 2.1GHz | 4x 32GB | RAID 930-8i | 8x 2.5" / 16 (4x AnyBay) | Open | 11 / 11 | 2x 1600W HS | Yes | Yes |
7X19A02UEA | 4x Platinum 8176 28C 165W 2.1GHz | 4x 32GB | RAID 930-8i | 8x 2.5" / 16 (4x AnyBay) | Open | 11 / 11 | 2x 1600W HS | Yes | Yes |
† Processor detail: Quantity, model, core count, TDP, core frequency
Models for Hong Kong, Taiwan, Korea (HTK)
All models have the following common features:
- No included drives (open drive bays)
- XCC Advanced with an available upgrade to XCC Enterprise
- No VGA port on the front of the server; available as an option
- Basic operator panel (no pull-out LCD Display Panel)
- No power cords included; ensure desired power cords are added to the order
- Slide Rail Kit (cable management arm is available but not included)
Model | Intel Xeon processors† |
Memory | RAID | Drive bays | Ethernet LOM |
Slots | Power supplies |
Front USB 3.0 |
---|---|---|---|---|---|---|---|---|
7X19A021CN | 2x Gold 5115 10C 85W 2.4GHz | 2x 16GB 2Rx8 | 2x RAID 930-8i | 16x 2.5" / 16 | 4x1Gb | 8 / 11 | 1x 750W HS | No |
7X19A01TCN | 2x Gold 5118 12C 105W 2.3GHz | 2x 16GB 2Rx8 | RAID 930-16i | 16x 2.5" / 16 | 4x1Gb | 11 / 11 | 1x 750W HS | Yes |
7X19A01RCN | 2x Gold 5120 14C 105W 2.2GHz | 2x 16GB 2Rx8 | RAID 930-16i | 16x 2.5" / 16 | 4x1Gb | 11 / 11 | 1x 750W HS | Yes |
7X19A01PCN | 2x Gold 5122 4C 105W 3.6GHz | 2x 16GB 2Rx8 | RAID 930-16i | 16x 2.5" / 16 | 4x1Gb | 11 / 11 | 1x 750W HS | Yes |
7X19A022CN | 2x Gold 6126 12C 125W 2.6GHz | 2x 16GB 2Rx8 | RAID 930-16i | 16x 2.5" / 16 | 4x1Gb | 11 / 11 | 1x 750W HS | Yes |
7X19A01WCN | 2x Gold 6130 16C 125W 2.1GHz | 2x 16GB 2Rx8 | RAID 930-16i | 16x 2.5" / 16 | 4x1Gb | 11 / 11 | 1x 750W HS | Yes |
7X19A02DCN | 2x Gold 6134 8C 130W 3.2GHz | 2x 16GB 2Rx8 | RAID 930-16i | 16x 2.5" / 16 | 4x1Gb | 11 / 11 | 1x 750W HS | Yes |
7X19A02ACN | 2x Gold 6136 12C 150W 3.0GHz | 2x 16GB 2Rx8 | RAID 930-16i | 16x 2.5" / 16 | 4x1Gb | 11 / 11 | 1x 750W HS | Yes |
7X19A00RCN | 2x Gold 6140 18C 140W 2.3GHz | 2x 16GB 2Rx8 | RAID 930-16i | 16x 2.5" / 16 | 4x1Gb | 11 / 11 | 1x 750W HS | Yes |
7X19A00ZCN | 2x Gold 6142 16C 150W 2.6GHz | 2x 16GB 2Rx8 | RAID 930-16i | 16x 2.5" / 16 | 4x1Gb | 11 / 11 | 1x 750W HS | Yes |
7X19A011CN | 2x Gold 6150 18C 165W 2.7GHz | 2x 16GB 2Rx8 | RAID 930-16i | 16x 2.5" / 16 | 4x1Gb | 11 / 11 | 1x 750W HS | Yes |
7X19A00BCN | 2x Gold 6152 22C 140W 2.1GHz | 2x 16GB 2Rx8 | RAID 930-16i | 16x 2.5" / 16 | 4x1Gb | 11 / 11 | 1x 750W HS | Yes |
7X19A007CN | 2x Platinum 8153 16C 125W 2.0GHz | 2x 16GB 2Rx8 | RAID 930-16i | 16x 2.5" / 16 | 4x1Gb | 11 / 11 | 1x 750W HS | Yes |
7X19A024CN | 2x Platinum 8156 4C 105W 3.6GHz | 2x 16GB 2Rx8 | RAID 930-16i | 16x 2.5" / 16 | 4x1Gb | 11 / 11 | 1x 750W HS | Yes |
7X19A026CN | 2x Platinum 8158 12C 150W 3.0GHz | 2x 16GB 2Rx8 | RAID 930-16i | 16x 2.5" / 16 | 4x1Gb | 11 / 11 | 1x 750W HS | Yes |
7X19A004CN | 2x Platinum 8160 24C 150W 2.1GHz | 2x 16GB 2Rx8 | RAID 930-16i | 16x 2.5" / 16 | 4x1Gb | 11 / 11 | 1x 750W HS | Yes |
7X19A00CCN | 2x Platinum 8164 26C 150W 2.0GHz | 2x 16GB 2Rx8 | RAID 930-16i | 16x 2.5" / 16 | 4x1Gb | 11 / 11 | 1x 750W HS | Yes |
7X19A00FCN | 2x Platinum 8170 26C 165W 2.1GHz | 2x 16GB 2Rx8 | RAID 930-16i | 16x 2.5" / 16 | 4x1Gb | 11 / 11 | 1x 750W HS | Yes |
7X19A00ECN | 2x Platinum 8176 28C 165W 2.1GHz | 2x 16GB 2Rx8 | RAID 930-16i | 16x 2.5" / 16 | 4x1Gb | 11 / 11 | 1x 750W HS | Yes |
7X19A027CN | 2x Gold 5120T 14C 105W 2.2GHz | 2x 16GB 2Rx8 | RAID 930-16i | 16x 2.5" / 16 | 4x1Gb | 11 / 11 | 1x 750W HS | Yes |
† Processor detail: Quantity, model, core count, TDP, core frequency
Models for India
All models have the following common features:
- No included drives (open drive bays)
- XCC Advanced with an available upgrade to XCC Enterprise
- No VGA port on the front of the server; available as an option
- Basic operator panel (no pull-out LCD Display Panel)
- Power cords included: 2.8m, 10A/250V, C13 to IS 6538, except for 7X19A005SG which includes 2.8m,10A/230V,C13 to CEE7-VII instead
Model | Intel Xeon processors† |
Memory | RAID | Drive bays | Ethernet LOM |
Slots | Power supplies |
Front USB 3.0 |
Rail kit |
---|---|---|---|---|---|---|---|---|---|
7X19A023SG | 2x Gold 5115 10C 85W 2.4GHz | 2x 8GB | RAID 530-8i | 8x 2.5" SAS / 16 | 4x1Gb | 8 / 11 | 1x 750W HS | No | Slide Rail |
7X19A013SG | 2x Gold 5115 10C 85W 2.4GHz | 2x 16GB | RAID 930-8i | 8x 2.5" SAS / 16 | 4x1Gb | 8 / 11 | 1x 750W HS | No | Slide Rail |
7X19A005SG | 2x Gold 5118 12C 105W 2.3GHz | 2x 16GB 2Rx8 | RAID 530-8i | 8x 2.5" SAS / 16 | 4x1Gb | 8 / 11 | 1x 750W HS | Yes | Friction Rail |
7X19A01ESG | 2x Gold 5118 12C 105W 2.3GHz | 2x 16GB | RAID 930-8i | 8x 2.5" SAS / 16 | 4x1Gb | 8 / 11 | 1x 750W HS | No | Slide Rail |
7X19A016SG | 2x Gold 5118 12C 105W 2.3GHz | 2x 16GB | RAID 530-8i | 8x 2.5" SAS / 16 | 4x1Gb | 8 / 11 | 1x 750W HS | No | Slide Rail |
7X19A020SG | 2x Gold 5120 14C 105W 2.2GHz | 2x 16GB | RAID 930-8i | 8x 2.5" SAS / 16 | 4x1Gb | 8 / 11 | 1x 750W HS | Yes | Option |
7X19A01KSG | 2x Gold 5120 14C 105W 2.2GHz | 2x 16GB | RAID 930-8i | 8x 2.5" SAS / 16 | 4x1Gb | 8 / 11 | 1x 750W HS | Yes | Slide Rail |
7X19A01QSG | 2x Gold 6134 8C 130W 3.2GHz | 2x 16GB | RAID 930-8i | 8x 2.5" SAS / 16 | 4x1Gb | 8 / 11 | 1x 1100W HS | Yes | Slide Rail |
7X19A01NSG | 2x Gold 6136 12C 150W 3.0GHz | 2x 16GB | RAID 930-8i | 8x 2.5" SAS / 16 | 4x1Gb | 8 / 11 | 1x 1100W HS | Yes | Slide Rail |
7X19A028SG | 2x Gold 6138 20C 125W 2.0GHz | 2x 16GB | RAID 930-8i | 8x 2.5" SAS / 16 | 4x1Gb | 8 / 11 | 1x 1100W HS | Yes | Slide Rail |
7X19A01HSG | 2x Gold 6140 18C 140W 2.3GHz | 2x 16GB | RAID 930-8i | 8x 2.5" SAS / 16 | 4x1Gb | 8 / 11 | 1x 1100W HS | Yes | Slide Rail |
7X19A01FSG | 2x Gold 6142 16C 150W 2.6GHz | 2x 16GB | RAID 930-8i | 8x 2.5" SAS / 16 | 4x1Gb | 8 / 11 | 1x 1100W HS | Yes | Slide Rail |
7X19A00ASG | 2x Gold 6152 22C 140W 2.1GHz | 2x 16GB | RAID 930-8i | 8x 2.5" SAS / 16 | 4x1Gb | 8 / 11 | 1x 1100W HS | Yes | Slide Rail |
7X19A006SG | 2x Platinum 8153 16C 125W 2.0GHz | 2x 16GB | RAID 930-8i | 8x 2.5" SAS / 16 | 4x1Gb | 8 / 11 | 1x 1100W HS | Yes | Slide Rail |
7X19A002SG | 2x Platinum 8160 24C 150W 2.1GHz | 2x 16GB | RAID 930-8i | 8x 2.5" SAS / 16 | 4x1Gb | 8 / 11 | 1x 1100W HS | Yes | Slide Rail |
7X19A00LSG | 2x Platinum 8164 26C 150W 2.0GHz | 2x 16GB | RAID 930-8i | 8x 2.5" SAS / 16 | 4x1Gb | 8 / 11 | 1x 1100W HS | Yes | Slide Rail |
7X19A00KSG | 2x Platinum 8170 26C 165W 2.1GHz | 2x 16GB | RAID 930-8i | 8x 2.5" SAS / 16 | 4x1Gb | 8 / 11 | 1x 1600W HS | Yes | Slide Rail |
7X19A00HSG | 2x Platinum 8176 28C 165W 2.1GHz | 2x 16GB | RAID 930-8i | 8x 2.5" SAS / 16 | 4x1Gb | 8 / 11 | 1x 1600W HS | Yes | Slide Rail |
† Processor detail: Quantity, model, core count, TDP, core frequency
Models for Japan
All models have the following common features:
- No included drives (open drive bays)
- VGA port on the front of the server
- Pull-out LCD Display Panel
- No power cords included; ensure desired power cords are added to the order
- Slide Rail Kit (cable management arm is available but not included)
Model | Intel Xeon processors† |
Memory | RAID | Drive bays | Ethernet LOM |
Slots | Power supplies |
Front USB 3.0 |
XCC Upgrade |
---|---|---|---|---|---|---|---|---|---|
7X19A01UJP | 2x Gold 5115 10C 85W 2.4GHz | 2x 16GB | RAID 930-8i | 8x 2.5" SAS / 16 | 4x10Gb RJ45 | 11 / 11 | 1x 1100W HS | No | Option |
7X19A02FJP | 2x Gold 6150 18C 165W 2.7GHz | 2x 16GB | RAID 930-8i | 8x 2.5" SAS / 16 | 4x10Gb SFP+ | 8 / 11 | 1x 1600W HS | Yes | Yes |
7X19A02EJP | 2x Platinum 8176 28C 165W 2.1GHz | 2x 16GB | RAID 930-8i | 8x 2.5" SAS / 16 | 4x10Gb SFP+ | 8 / 11 | 1x 1600W HS | Yes | Yes |
† Processor detail: Quantity, model, core count, TDP, core frequency
Models for Latin American regions (except Brazil)
All models have the following common features:
- No included drives (open drive bays)
- VGA port on the front of the server
- Pull-out LCD Display Panel
- USB 3.0 port on the front of the server
- No power cords included; ensure desired power cords are added to the order
Model | Intel Xeon processors† |
Memory | RAID | Drive bays | Ethernet LOM |
Slots | Power supplies |
XCC Upgrade |
Rail kit |
---|---|---|---|---|---|---|---|---|---|
7X19A037LA | 2x Gold 6140 18C 140W 2.3GHz | 12x 16GB 2Rx8 | RAID 930-8i | 8x 2.5" SAS / 16 | Open | 11 / 11 | 2x 1100W HS | Yes | Slide Rail |
7X19A033LA | 2x Gold 6148 20C 150W 2.4GHz | 12x 16GB 2Rx8 | RAID 930-8i | 8x 2.5" SAS / 16 | Open | 11 / 11 | 2x 1100W HS | Yes | Slide Rail |
7X19A032LA | 2x Platinum 8153 16C 125W 2.0GHz | 12x 32GB | RAID 930-8i | 8x 2.5" SAS / 16 | Open | 11 / 11 | 2x 1100W HS | Yes | Slide Rail |
7X19A03ELA | 2x Platinum 8160 24C 150W 2.1GHz | 12x 32GB | RAID 930-8i | 8x 2.5" SAS / 16 | Open | 11 / 11 | 2x 1100W HS | Yes | Slide Rail |
7X19A03CLA | 2x Platinum 8164 26C 150W 2.0GHz | 12x 32GB | RAID 930-8i | 8x 2.5" SAS / 16 | Open | 11 / 11 | 2x 1600W HS | Yes | Slide Rail |
7X19A03BLA | 2x Platinum 8170 26C 165W 2.1GHz | 12x 32GB | RAID 930-8i | 8x 2.5" SAS / 16 | Open | 11 / 11 | 2x 1600W HS | Yes | Slide Rail |
7X19A03FLA* | 4x Platinum 8170 26C 165W 2.1GHz | 16x 32GB | RAID 930-16i | 16x 2.5" / 16 (4x AnyBay) | 4x1Gb | 11 / 11 | 2x 1600W HS | Option | Slide Rail + CMA |
7X19A03HLA* | 4x Platinum 8170 26C 165W 2.1GHz | 32x 16GB 2Rx8 | RAID 930-16i | 16x 2.5" / 16 (4x AnyBay) | 4x1Gb | 11 / 11 | 2x 1600W HS | Option | Slide Rail + CMA |
7X19A03ALA | 2x Platinum 8176 28C 165W 2.1GHz | 12x 32GB | RAID 930-8i | 8x 2.5" SAS / 16 | Open | 11 / 11 | 2x 1600W HS | Yes | Slide Rail |
7X19A03GLA* | 4x Platinum 8176 28C 165W 2.1GHz | 16x 32GB | RAID 930-16i | 16x 2.5" / 16 (4x AnyBay) | 4x1Gb | 11 / 11 | 2x 1600W HS | Option | Slide Rail + CMA |
7X19A03JLA* | 4x Platinum 8176 28C 165W 2.1GHz | 32x 16GB 2Rx8 | RAID 930-16i | 16x 2.5" / 16 (4x AnyBay) | 4x1Gb | 11 / 11 | 2x 1600W HS | Option | Slide Rail + CMA |
† Processor detail: Quantity, model, core count, TDP, core frequency
* Also includes one external USB DVD-RW drive
Models for USA and Canada
All models have the following common features:
- No included drives (open drive bays)
- XCC Advanced with an available upgrade to XCC Enterprise
- VGA port on the front of the server
- Pull-out LCD Display Panel
- Front USB ports are USB 2.0
- No power cords included; ensure desired power cords are added to the order
- Slide Rail Kit (cable management arm is available but not included)
Model | Intel Xeon processors† |
Memory | RAID | Drive bays | Ethernet LOM |
Slots | Power supplies |
---|---|---|---|---|---|---|---|
7X19A008NA | 4x Gold 5115 10C 85W 2.4GHz | 4x 32GB | RAID 930-8i | 8x 2.5" / 16 (4x AnyBay) | Open | 11 / 11 | 2x 1100W HS |
7X19A018NA | 4x Gold 5118 12C 105W 2.3GHz | 4x 32GB | RAID 930-8i | 8x 2.5" / 16 (4x AnyBay) | Open | 11 / 11 | 2x 1100W HS |
7X19A019NA | 4x Gold 5120 14C 105W 2.2GHz | 4x 32GB | RAID 930-8i | 8x 2.5" / 16 (4x AnyBay) | Open | 11 / 11 | 2x 1100W HS |
7X19A01CNA | 4x Gold 6126 12C 125W 2.6GHz | 4x 32GB | RAID 930-8i | 8x 2.5" / 16 (4x AnyBay) | Open | 11 / 11 | 2x 1100W HS |
7X19A00SNA | 4x Gold 6130 16C 125W 2.1GHz | 4x 32GB | RAID 930-8i | 8x 2.5" / 16 (4x AnyBay) | Open | 11 / 11 | 2x 1100W HS |
7X19A00UNA | 4x Gold 6138 20C 125W 2.0GHz | 4x 32GB | RAID 930-8i | 8x 2.5" / 16 (4x AnyBay) | Open | 11 / 11 | 2x 1100W HS |
7X19A00YNA | 4x Gold 6148 20C 150W 2.4GHz | 4x 32GB | RAID 930-8i | 8x 2.5" / 16 (4x AnyBay) | Open | 11 / 11 | 2x 1600W HS |
7X19A014NA | 4x Gold 6150 18C 165W 2.7GHz | 4x 32GB | RAID 930-8i | 8x 2.5" / 16 (4x AnyBay) | Open | 11 / 11 | 2x 1600W HS |
7X19A015NA | 4x Gold 6152 22C 140W 2.1GHz | 4x 32GB | RAID 930-8i | 8x 2.5" / 16 (4x AnyBay) | Open | 11 / 11 | 2x 1600W HS |
7X19A01LNA | 4x Platinum 8160 24C 150W 2.1GHz | 4x 32GB | RAID 930-8i | 8x 2.5" / 16 (4x AnyBay) | Open | 11 / 11 | 2x 1600W HS |
7X19A01YNA | 4x Platinum 8164 26C 150W 2.0GHz | 4x 32GB | RAID 930-8i | 8x 2.5" / 16 (4x AnyBay) | Open | 11 / 11 | 2x 1600W HS |
7X19A00JNA | 4x Platinum 8170 26C 165W 2.1GHz | 4x 32GB | RAID 930-8i | 8x 2.5" / 16 (4x AnyBay) | Open | 11 / 11 | 2x 1600W HS |
7X19A00TNA | 4x Platinum 8176 28C 165W 2.1GHz | 4x 32GB | RAID 930-8i | 8x 2.5" / 16 (4x AnyBay) | Open | 11 / 11 | 2x 1600W HS |
† Processor detail: Quantity, model, core count, TDP, core frequency
Processor options
The SR850 supports Gold and Platinum level processors in the Intel Xeon Processor Scalable Family.
The server supports up to four processors:
- Processors 1 and 2 are installed in sockets on the system board.
- Processors 3 and 4 are installed on the Processor and Memory Expansion Tray.
The SR850 Processor and Memory Expansion Tray has a patent-pending sliding and rolling lift mechanism that requires only a one-handed operation to insert or remove from the server. It has a toolless design for superior usability, serviceability and reliability.
Figure 6. SR850 Processor and Memory Expansion Tray
The ordering information for the Processor and Memory Expansion Tray is shown in the following table.
Part number | Feature code | Description |
---|---|---|
7B27A03953 | AUPY | SR850 Processor and Memory Expansion Tray |
The following processor quantities are supported:
- Two processors, installed in sockets 1 and 2, without the Processor and Memory Expansion Tray
- Four processors, installed in all four sockets
- Configurations of one processor or three processors are supported via Special Bid
The SR850 supports the Intel Xeon Processor Scalable Family options listed in the following table.
All supported processors have the following characteristics:
- 14 nm process technology
- Six DDR4 memory channels
- 48 PCIe 3.0 I/O lanes
- 1 MB L2 cache
- 1.375 MB L3 cache per core (except where larger, as noted with ** in the table below)
- Intel Hyper-Threading Technology
- Intel Turbo Boost Technology 2.0
- Intel Advanced Vector Extensions 512 (AVX-512)
- Intel Ultra Path Interconnect (UPI) links at 10.4 GT/s (replaces QPI)
With two processors installed, the two processors are connected together using one UPI link. With four processors installed, the processors are connected together using a ring topology, using two UPI links, one to each adjacent processor in the ring.
Processors with the T suffix have more robust thermal characteristics (higher T-case). Processors with the M suffix support greater than 768 GB per processor.
Part number |
Feature code |
Description | Memory speed |
Supports >768 GB per CPU |
L3 cache | AVX-512 FMA units |
---|---|---|---|---|---|---|
7XG7A04974 | AX8M | Intel Xeon Gold 5115 10C 85W 2.4GHz | 2400 MHz | No | 13.75 MB | 1 |
4XG7A09098 | B248 | Intel Xeon Gold 5117 14C 105W 2.0GHz | 2400 MHz | No | 19.25 MB | 1 |
7XG7A04971 | AX7D | Intel Xeon Gold 5118 12C 105W 2.3GHz | 2400 MHz | No | 16.5 MB | 1 |
7XG7A04973 | B259 | Intel Xeon Gold 5119T 14C 85W 1.9GHz | 2400 MHz | No | 19.25 MB | 1 |
7XG7A04970 | AX7C | Intel Xeon Gold 5120 14C 105W 2.2GHz | 2400 MHz | No | 19.25 MB | 1 |
7XG7A04972 | AX7E | Intel Xeon Gold 5120T 14C 105W 2.2GHz | 2400 MHz | No | 19.25 MB | 1 |
7XG7A04959 | AX70 | Intel Xeon Gold 5122 4C 105W 3.6GHz | 2666 MHz* | No | 16.5 MB** | 2* |
7XG7A03949 | AWEX | Intel Xeon Gold 6126 12C 125W 2.6GHz | 2666 MHz | No | 19.25 MB** | 2 |
None† | AX73 | Intel Xeon Gold 6126T 12C 125W 2.6GHz | 2666 MHz | No | 19.25 MB** | 2 |
7XG7A04958 | B251 | Intel Xeon Gold 6128 6C 115W 3.4GHz | 2666 MHz | No | 19.25 MB** | 2 |
7XG7A03945 | AX6D | Intel Xeon Gold 6130 16C 125W 2.1GHz | 2666 MHz | No | 22 MB | 2 |
7XG7A04961 | AX72 | Intel Xeon Gold 6130T 16C 125W 2.1GHz | 2666 MHz | No | 22 MB | 2 |
7XG7A03947 | B24N | Intel Xeon Gold 6132 14C 140W 2.6GHz | 2666 MHz | No | 19.25 | 2 |
7XG7A04957 | AX6Y | Intel Xeon Gold 6134 8C 130W 3.2GHz | 2666 MHz | No | 24.75 MB** | 2 |
7XG7A04968 | B258 | Intel Xeon Gold 6134M 8C 130W 3.2GHz | 2666 MHz | Yes | 24.75 MB** | 2 |
7XG7A03948 | AX6W | Intel Xeon Gold 6136 12C 150W 3.0GHz | 2666 MHz | No | 24.75 MB** | 2 |
7XG7A03943 | AX6Q | Intel Xeon Gold 6138 20C 125W 2.0GHz | 2666 MHz | No | 27.5 MB | 2 |
7XG7A04960 | B252 | Intel Xeon Gold 6138T 20C 125W 2.0GHz | 2666 MHz | No | 27.5 MB | 2 |
7XG7A03944 | AX6R | Intel Xeon Gold 6140 18C 140W 2.3GHz | 2666 MHz | No | 24.75 MB | 2 |
7XG7A04967 | B257 | Intel Xeon Gold 6140M 18C 140W 2.3GHz | 2666 MHz | Yes | 24.75 MB | 2 |
7XG7A03946 | AX6E | Intel Xeon Gold 6142 16C 150W 2.6GHz | 2666 MHz | No | 22 MB | 2 |
7XG7A04966 | B256 | Intel Xeon Gold 6142M 16C 150W 2.6GHz | 2666 MHz | Yes | 22 MB | 2 |
None† | AX6X | Intel Xeon Gold 6144 8C 150W 3.5GHz | 2666 MHz | No | 24.75 MB** | 2 |
None† | AX6V | Intel Xeon Gold 6146 12C 165W 3.2GHz | 2666 MHz | No | 24.75 MB** | 2 |
7XG7A03942 | AWEW | Intel Xeon Gold 6148 20C 150W 2.4GHz | 2666 MHz | No | 27.5 MB | 2 |
7XG7A06760 | AX6T | Intel Xeon Gold 6150 18C 165W 2.7GHz | 2666 MHz | No | 24.75 MB | 2 |
7XG7A03941 | AX6P | Intel Xeon Gold 6152 22C 140W 2.1GHz | 2666 MHz | No | 30.25 MB | 2 |
None† | AX6S | Intel Xeon Gold 6154 18C 200W 3.0GHz | 2666 MHz | No | 24.75 MB | 2 |
7XG7A03938 | AX6L | Intel Xeon Platinum 8153 16C 125W 2.0GHz | 2666 MHz | No | 22 MB | 2 |
7XG7A03939 | AWEV | Intel Xeon Platinum 8156 4C 105W 3.6GHz | 2666 MHz | No | 16.5 MB** | 2 |
7XG7A04969 | AX7B | Intel Xeon Platinum 8158 12C 150W 3.0GHz | 2666 MHz | No | 24.75 MB** | 2 |
7XG7A03937 | AWGJ | Intel Xeon Platinum 8160 24C 150W 2.1GHz | 2666 MHz | No | 33 MB | 2 |
7XG7A04965 | B255 | Intel Xeon Platinum 8160M 24C 150W 2.1GHz | 2666 MHz | Yes | 33 MB | 2 |
None† | AX6N | Intel Xeon Platinum 8160T 24C 150W 2.1GHz | 2666 MHz | No | 33 MB | 2 |
7XG7A03936 | AX6K | Intel Xeon Platinum 8164 26C 150W 2.0GHz | 2666 MHz | No | 35.75 MB | 2 |
None† | AX6M | Intel Xeon Platinum 8168 24C 205W 2.7GHz | 2666 MHz | No | 33 MB | 2 |
7XG7A03935 | AX6J | Intel Xeon Platinum 8170 26C 165W 2.1GHz | 2666 MHz | No | 35.75 MB | 2 |
7XG7A04964 | B254 | Intel Xeon Platinum 8170M 26C 165W 2.1GHz | 2666 MHz | Yes | 35.75 MB | 2 |
7XG7A03934 | AX6H | Intel Xeon Platinum 8176 28C 165W 2.1GHz | 2666 MHz | No | 38.5 MB | 2 |
7XG7A04963 | B253 | Intel Xeon Platinum 8176M 28C 165W 2.1GHz | 2666 MHz | Yes | 38.5 MB | 2 |
None† | AX6G | Intel Xeon Platinum 8180 28C 205W 2.5GHz | 2666 MHz | No | 38.5 MB | 2 |
None† | AX74 | Intel Xeon Platinum 8180M 28C 205W 2.5GHz | 2666 MHz | Yes | 38.5 MB | 2 |
* All Gold 5000-level processors, except the 5122, support 2400 MHz memory speeds and have one AVX-512 512-bit FMA units. The 5122 processor supports 2666 MHz and has two FMA units
** L3 cache is 1.375 MB per core except for processor indicated with ** where the cache size is larger
† These high-performance processors have high thermal requirements and can only be ordered in a configure-to-order (CTO) configuration. No field upgrade of processors is supported. In addition, if these processors are used, then no backplanes or drives can be installed, and there are cooling restrictions. See the Internal storage and Cooling sections for details.
Memory options
The SR850 server supports TruDDR4 memory. TruDDR4 memory uses the highest-quality components sourced from Tier 1 DRAM suppliers and only memory that meets strict tolerances is selected. It is compatibility tested and tuned to maximize performance and reliability.
TruDDR4 memory has a unique signature programmed into the DIMM, which enables ThinkSystem servers to verify whether the memory installed is qualified and supported. From a service and support standpoint, TruDDR4 memory automatically assumes the system's warranty, and service and support provided worldwide.
The SR850 supports up to 12 DIMMs per processor, for a total of 48 DIMMs when four processors are installed. Each processor has six memory channels, and supports one or two DIMMs per channel.
All DIMMs can operate at a speed of 2666 MHz, both at 1 DIMM per channel and 2 DIMMs per channel. However, if the processor selected has a lower memory bus speed (eg 2400 MHz), then all DIMMs will operate at that lower speed.
The following table lists the memory options that are available for the SR850 server.
Part number |
Feature code |
Description | Maximum supported |
---|---|---|---|
RDIMMs | |||
7X77A01301 | AUU1 | ThinkSystem 8GB TruDDR4 2666 MHz (1Rx8 1.2V) RDIMM | 48 (12 per processor) |
7X77A01302 | AUNB | ThinkSystem 16GB TruDDR4 2666 MHz (1Rx4 1.2V) RDIMM | 48 (12 per processor) |
7X77A01303 | AUNC | ThinkSystem 16GB TruDDR4 2666 MHz (2Rx8 1.2V) RDIMM | 48 (12 per processor) |
7X77A01304 | AUND | ThinkSystem 32GB TruDDR4 2666 MHz (2Rx4 1.2V) RDIMM | 48 (12 per processor) |
LRDIMMs | |||
7X77A01305 | AUNE | ThinkSystem 64GB TruDDR4 2666 MHz (4Rx4 1.2V) LRDIMM | 48 (12 per processor) |
3DS RDIMMs | |||
7X77A01307 | AUNF | ThinkSystem 128GB TruDDR4 2666 MHz (8Rx4 1.2V) 3DS RDIMM | 48 (12 per processor) |
The following rules apply when selecting the memory configuration:
- The server supports RDIMMs, LRDIMMs and 3DS RDIMMs. UDIMMs are not supported.
- Mixing RDIMMs and LRDIMMs is not supported.
- Mixing 3DS RDIMMs with either RDIMMs or LRDIMMs is not supported.
- Mixing x4 and x8 DIMMs is supported.
- When mixing 16 GB and 32 GB DIMMs in the same configuration, use 16GB 2Rx8 DIMMs instead of 16 GB 1Rx4 DIMMs for better performance
- For best performance, populate memory DIMMs in quantities of 6 or 12 per processor, so that all memory channels are used.
The following memory protection technologies are supported:
- ECC
- SDDC (for x4-based memory DIMMs; look for "x4" in the DIMM description)
- ADDDC (for x4-based memory DIMMs)
- Memory channel mirroring
- Memory rank sparing
If memory channel mirroring is used, then DIMMs must be installed in pairs (minimum of one pair per processor), and both DIMMs in a pair must be identical in type and size. 50% of the installed capacity is available to the operating system.
If memory rank sparing is used, then a minimum of one quad-rank DIMM or two single-rank or dual-rank DIMMs must be installed per populated channel (the DIMMs do not need to be identical). In rank sparing mode, one rank of a DIMM in each populated channel is reserved as spare memory. The largest rank in the channel will be automatically selected as the spare rank. The amount of memory available to the operating system depends on the number, capacity and rank counts of the DIMMs installed.
Internal storage
The server can support up to 16x 2.5-inch drives, SAS, SATA or NVMe, depending on the selected backplane configuration. You can mix drives in the same server, but not in the same array. Drives are all installed from the front of the server. The server also supports one or two M.2 drives, installed in an M.2 adapter.
In this section:
- Backplanes and drive bays
- Adapters and cabling
- Field upgrades
- M.2 drives
- SED encryption key management with ISKLM
Backplanes and drive bays
The SR850 supports various internal storage configurations based on two different backplanes:
- 8-drive SAS/SATA backplane for 8x 2.5-inch SAS or SATA drives
- 8-drive SAS/SATA+AnyBay backplane for either:
- 8x 2.5-inch SAS or SATA drives
- 4x 2.5-inch SAS or SATA drives + 4x 2.5-inch U.2 (NVMe) drives
For configure-to-order (CTO) configurations, ordering information for the backplanes is in the following table.
Part number | Feature code | Description |
---|---|---|
None* | AUR5 | ThinkSystem 2U 2.5" AnyBay 8-Bay Backplane Kit |
None* | AURA | ThinkSystem 2U/Tower 2.5" SATA/SAS 8-Bay Backplane Kit |
* Backplanes are configure-to-order (CTO) only; however, upgrade kits are available that include backplanes, as described in the Field upgrades section below.
Regular 2.5-inch SAS/SATA drive bays support only SAS or SATA drives, however the Lenovo AnyBay drive bay design allows a choice of SATA, SAS or NVMe drives. This design enables the flexibility to configure some of the bays with high-performance PCIe SSDs and still use the remaining bays for high-capacity HDDs, which is the ideal solution for storage tiering.
Backplane connections are as follows:
- The 8-drive SAS/SATA backplane has two SAS/SATA connectors and connects to a supported RAID controller or SAS HBA.
- The 8-drive SAS/SATA+AnyBay backplane has two SAS/SATA connectors and connects to a supported RAID controller or SAS HBA plus four PCIe connectors to connect to either two PCIe connectors on the Processor and Memory Expansion Tray (see Figure 4), or four PCIe connectors on a NVMe Switch adapter installed in a PCIe slot.
Five drive configurations are possible with these two backplanes:
- 8 drive bays, all SAS/SATA
- 8 drive bays, where 4 are AnyBay
- 16 drive bays, all SAS/SATA
- 16 drive bays, where 4 are AnyBay
- 16 drive bays, where 8 are AnyBay
- Zero drive bays without any backplanes installed
The first five configurations are shown in the following figure.
Figure 7. Drive bay configurations
Adapters and cabling
This section describes the adapter and cabling requirements for each of the five configurations. There are two aspects of the server configuration that determine what adapters are needed:
- For configurations with two SAS/SATA backplanes, you can select either one 16-port SAS/SATA adapter or two 8-port SAS/SATA adapters
- For AnyBay drive bays, cabling varies depending on whether the server has four processors and the Processor and Memory Expansion Tray (with its two NVMe connectors) installed. If the server has only two processors configured, then the NVMe ports are provided by an NVMe Switch adapter.
The five drive bay configurations are shown in the subsections below. Where there are different adapter and cabling options, or for 2 or 4 processors, they are shown by the letters A, B, C and D. These configuration numbers are also later references in the Field upgrades section.
- 8x drive bays, all SAS/SATA
- 8x drive bays, where 4 are AnyBay
- 16x drive bays, all SAS/SATA
- 16x drive bays, where 4 are AnyBay
- 16x drive bays, where 8 are AnyBay
Tip: The adapters are described in detail in the Controllers for internal storage section.
1. 8 drive bays, all SAS/SATA
In this drive bay configuration, all eight drives are connected to one 8-port SAS/SATA RAID adapter or HBA using two backplane cables, as shown in the following figure.
Figure 8. Adapter and cabling for 8x drive bays, all SAS/SATA
2. 8 drive bays, where 4 are AnyBay
In 8-drive bay configurations where four of those drive bays are AnyBay drive bays, possible adapter and cabling configurations are shown in the following figure.
When only two processors are selected, anAnyBay drive bays and NVMe Switch Adapter is used to provide the four needed NVMe ports. When four processors are selected, the NVMe ports on the Processor and Memory Expansion Tray are used to connect to the NVMe connectors on the backplane.
In this configuration you can have up to eight SAS or SATA drives, or you can instead put up to four NVMe drives in the AnyBay drive bays, along with up to four SAS/SATA drives in the other drive bays.
Figure 9. Adapter and cabling for 8 drive bays, where 4 of the bays are AnyBay
3. 16 drive bays, all SAS/SATA
In 16-bay configurations where all 16 drive bays are SAS/SATA drives, you can use either two 8-port SAS/SATA RAID adapters or HBAs or one 16-port SAS/SATA RAID adapter or HBA. These choices are shown in the following figure.
Figure 10. Adapter and cabling for 16 drive bays, all SAS/SATA
4. 16 drive bays, where 4 are AnyBay
In 16-drive configurations where four of the bays are AnyBay drive bays, you can elect to have either one 16-port adapter or two 8-port adapters for SAS/SATA connectivity. In addition, the NVMe connectivity depends on whether you have two or four processors installed: for two-processor systems, an NVMe Switch Adapter is required; for four-processor systems, the onboard NVMe ports can be used. The configurations are shown in the following figure.
Figure 11. Adapter and cabling for 16 drive bays, where 4 of the bays are AnyBay
5. 16 drive bays, where 8 are AnyBay
In 16-drive configurations where eight of the bays are AnyBay drive bays, you can select either one 16-port adapter or two 8-port adapters for SAS/SATA connectivity. In addition, the NVMe connectivity depends on whether you have two or four processors installed:
- For two-processor systems, two NVMe Switch Adapters are required
- For four-processor systems, the onboard NVMe ports is used for four of the AnyBay drive bays and an NVMe Switch Adapter is needed for the other four AnyBay drive bays.
The configurations are shown in the following figure.
Figure 12. Adapter and cabling for 16 drive bays, where 8 of the bays are AnyBay
Field upgrades
This section describes how customers can upgrade their 8-bay configurations after the initial purchase of the server. The two backplane upgrade kits are listed in the following table.
Part number | Feature code | Description |
---|---|---|
7C57A03998 | AXP7 | ThinkSystem SR850/SR860 2.5" SATA/SAS 8-Bay BP Kit |
7C57A03999 | AXP8 | ThinkSystem SR850/SR860 2.5" AnyBay 8-Bay BP Kit |
The ThinkSystem SR850 2.5" SATA/SAS 8-Bay BP Kit, 7C57A03998, contains the following items:
- 1x 8-bay SAS/SATA backplane
- 1x backplane power cable
- 2x 900mm SAS/SATA cables
- 2x 720mm SAS/SATA cables
- 8x 1-bay fillers
The ThinkSystem SR850 2.5" AnyBay 8-Bay BP Kit, 7C57A03999, contains the following items:
- 1x 8-bay AnyBay backplane (4 SAS/SATA connectors, 4 AnyBay connectors)
- 1x backplane power cable
- 1x 900mm SAS/SATA cable
- 1x 720mm SAS/SATA cable
- 4x 750mm NVMe cables for use with NVMe Switch Adapter
- 2x 900mm NVMe cables for use with onboard NVMe ports
In addition to the backplane kits, you will need a RAID adapter or HBA, and for some upgrades you may also need an NVMe adapter. Upgrades needed are listed in the following two tables. Upgrading from an 8-port SAS/SATA adapter to a 16-port SAS/SATA adapter is supported, however that requires removing the existing 8-port adapter.
Tip: The adapters are described in the Controllers for internal storage section.
The following table lists the available upgrades for SR850 servers with a single SAS/SATA backplane (See Configuration 1 above).
Target configuration | Remove existing 8-port adapter |
Components to add |
---|---|---|
Servers with two processors | ||
16x bays (all SAS/SATA) with 2x 8-port adapters (Config 3A) |
No | 1x SAS/SATA backplane 1x 8-port adapter |
16x bays (4x AnyBay) with 2x 8-port adapters, 1x NVMe adapter (Config 4A) |
No | 1x AnyBay backplane 1x 8-port adapter, 1x NVMe adapter |
16x bays (all SAS/SATA) with 1x 16-port adapter (Config 3B) |
Yes | 1x SAS/SATA backplane 1x 16-port adapter |
16x bays (4x AnyBay) with 1x 16-port adapter, 1x NVMe adapter (Config 4B) |
Yes | 1x AnyBay backplane 1x 16-port adapter, 1x NVMe adapter |
Servers with four processors | ||
16x bays (all SAS/SATA) with 2x 8-port adapters (Config 3A) |
No | 1x SAS/SATA backplane 1x 8-port adapter |
16x bays (4x AnyBay) with 2x 8-port adapters (Config 4C) |
No | 1x AnyBay backplane 1x 8-port adapter, cables to onboard NVMe ports |
16x bays (all SAS/SATA) with 1x 16-port adapter (Config 3B) |
Yes | 1x SAS/SATA backplane 1x 16-port adapter |
16x bays (4x AnyBay) with 1x 16-port adapter (Config 4D) |
Yes | 1x AnyBay backplane 1x 16-port adapter, cables to onboard NVMe ports |
The following table lists the available upgrades for SR850 servers with a single AnyBay backplane (See Configuration 2 above).
Target configuration | Remove existing 8-port adapter |
Components to add |
---|---|---|
Servers with two processors | ||
16x bays (4x AnyBay) with 2x 8-port adapters, 1x NVMe adapter (Config 4A) |
No | 1x SAS/SATA backplane 1x 8-port adapter |
16x bays (8x AnyBay) with 2x 8-port adapters, 2x NVMe adapters (Config 5A) |
No | 1x AnyBay backplane 1x 8-port adapter, 1x NVMe adapter |
16x bays (4x AnyBay) with 1x 16-port adapter, 1x NVMe adapter (Config 4B) |
Yes | 1x SAS/SATA backplane 1x 16-port adapter |
16x bays (8x AnyBay) with 2x 8-port adapters, 2x NVMe adapters (Config 5B) |
Yes | 1x AnyBay backplane 1x 16-port adapter, 1x NVMe adapter |
Servers with four processors | ||
16x bays (4x AnyBay) with 2x 8-port adapters (Config 4C) |
No | 1x SAS/SATA backplane 1x 8-port adapter |
16x bays (8x AnyBay) with 2x 8-port adapters, 1x NVMe adapter (Config 5C) |
No | 1x AnyBay backplane 1x 8-port adapter, 1x NVMe adapter |
16x bays (4x AnyBay) with 1x 16-port adapter (Config 4D) |
Yes | 1x SAS/SATA backplane 1x 16-port adapter |
16x bays (8x AnyBay) with 2x 8-port adapters, 1x NVMe adapter (Config 5D) |
Yes | 1x AnyBay backplane 1x 16-port adapter, 1x NVMe adapter |
M.2 drives
The server supports one or two M.2 form-factor SATA drives for use as an operating system boot solution. With two M.2 drives configured, the drives are configured by default as a RAID-1 mirrored pair for redundancy.
The M.2 drives install into an M.2 adapter which in turn is installed in a dedicated slot on the system board. See the internal view of the server in the Components and connectors section for the location of the M.2 slot.
There are two M.2 adapters supported, as listed in the following table.
Part number | Feature code | Description | Maximum supported |
---|---|---|---|
7Y37A01092 | AUMU | ThinkSystem M.2 Enablement Kit (contains the Single M.2 Boot Adapter; supports 1 drive) |
1 |
7Y37A01093 | AUMV | ThinkSystem M.2 with Mirroring Enablement Kit (contains the Dual M.2 Boot Adapter, supports 1 or 2 drives) |
1 |
Supported drives are listed in the Internal drive options section.
For details about M.2 components, see the ThinkSystem M.2 Drives and M.2 Adapters product guide:
https://lenovopress.com/lp0769-thinksystem-m2-drives-adapters
SED encryption key management with SKLM
The server supports self-encrypting drives (SEDs) as listed in the Internal drive options section. To effectively manage a large deployment of these drives in Lenovo servers, IBM Security Key Lifecycle Manager (SKLM) offers a centralized key management solution.
A Lenovo Feature on Demand (FoD) upgrade is used to enable this SKLM support in the management processor of the server. The following table lists the part numbers and feature codes for the upgrades.
Part number | Feature code | Description |
---|---|---|
Security Key Lifecycle Manager - FoD (United States, Canada, Asia Pacific, and Japan) | ||
00D9998 | A5U1 | SKLM for System x/ThinkSystem w/SEDs - FoD per Install with 1 year S&S |
00D9999 | AS6C | SKLM for System x/ThinkSystem w/SEDs - FoD per Install with 3 year S&S |
Security Key Lifecycle Manager - FoD (Latin America, Europe, Middle East, and Africa) | ||
00FP648 | A5U1 | SKLM for System x/ThinkSystem w/SEDs - FoD per Install with 1 year S&S |
00FP649 | AS6C | SKLM for System x/ThinkSystem w/SEDs - FoD per Install with 3 year S&S |
The IBM Security Key Lifecycle Manager software is available from Lenovo using the ordering information listed in the following table.
Part number | Description |
---|---|
7S0A007FWW | IBM Security Key Lifecycle Manager Basic Edition Install License + SW Subscription & Support 12 Months |
7S0A007HWW | IBM Security Key Lifecycle Manager For Raw Decimal Terabyte Storage Resource Value Unit License + SW Subscription & Support 12 Months |
7S0A007KWW | IBM Security Key Lifecycle Manager For Raw Decimal Petabyte Storage Resource Value Unit License + SW Subscription & Support 12 Months |
7S0A007MWW | IBM Security Key Lifecycle Manager For Usable Decimal Terabyte Storage Resource Value Unit License + SW Subscription & Support 12 Months |
7S0A007PWW | IBM Security Key Lifecycle Manager For Usable Decimal Petabyte Storage Resource Value Unit License + SW Subscription & Support 12 Months |
Controllers for internal storage
The SR850 supports internal SAS and SATA drives with the addition of a RAID adapter or HBA. For NVMe support, the server offers two onboard NVMe ports on the processor and memory expansion tray (with four processors) and two ports with the use of an NVMe Switch Adapter.
The following table lists the adapters used for the internal storage of the SR850 server.
Tip: Unlike System x RAID adapters, no upgrades are available for these RAID adapters. All supported functions are included with the base part numbers.
Part number |
Feature code |
Description | Slots supported |
Maximum supported |
---|---|---|---|---|
SAS/SATA HBA | ||||
7Y37A01088 | AUNL | ThinkSystem 430-8i SAS/SATA 12Gb HBA | 10 , 2 | 2 |
7Y37A01089 | AUNM | ThinkSystem 430-16i SAS/SATA 12Gb HBA | 10 , 2 | 1 |
RAID adapters | ||||
7Y37A01082 | AUNG | ThinkSystem RAID 530-8i PCIe 12Gb Adapter | 10 , 2 | 2 |
7Y37A01083* | AUNH* | ThinkSystem RAID 730-8i 1GB Cache PCIe 12Gb Adapter | 10 , 2 | 2 |
4Y37A09722 | B4RQ | ThinkSystem RAID 730-8i 2GB Flash PCIe 12Gb Adapter | 10 , 2 | 2 |
7Y37A01084 | AUNJ | ThinkSystem RAID 930-8i 2GB Flash PCIe 12Gb Adapter | 10 , 2 | 2 |
7Y37A01085 | AUNK | ThinkSystem RAID 930-16i 4GB Flash PCIe 12Gb Adapter | 10 , 2 | 1 |
4Y37A09721 | B31E | ThinkSystem RAID 930-16i 8GB Flash PCIe 12Gb Adapter | 10 , 2 | 1 |
NVMe adapter | ||||
7Y37A01081 | AUV2 | ThinkSystem 1610-4P NVMe Switch Adapter | 1, 11 | 2 |
* * The RAID 730-8i 1GB Cache adapter is not available in USA and Canada.
The following two tables compare the functions of the storage adapters.
Feature | RAID 530-8i | RAID 730-8i 1GB** | RAID 730-8i 2GB | RAID 930-8i | RAID 930-16i |
---|---|---|---|---|---|
Adapter type | RAID controller | RAID controller | RAID controller | RAID controller | RAID controller |
Part number | 7Y37A01082 | 7Y37A01083 | 4Y37A09722 | 7Y37A01084 | 7Y37A01085 4Y37A09721 |
Form factor | PCIe HHHL | PCIe low profile | PCIe low profile | PCIe HHHL | PCIe HHHL |
Controller chip | LSI SAS3408 | LSI SAS3108 | LSI SAS3108 | LSI SAS3508 | LSI SAS3516 |
Broadcom equivalent | MegaRAID 9440-8i | MegaRAID 9361-8i | MegaRAID 9361-8i | MegaRAID 9460-8i | MegaRAID 9460-16i |
Host interface | PCIe 3.0x8 | PCIe 3.0x8 | PCIe 3.0x8 | PCIe 3.0x8 | PCIe 3.0x8 |
Port interface | 12 Gb SAS | 12 Gb SAS | 12 Gb SAS | 12 Gb SAS | 12 Gb SAS |
Number of ports | 8 | 8 | 8 | 8 | 16 |
Port connectors | 2x Mini-SAS HD x4 (SFF-8643) | 2x Mini-SAS HD x4 (SFF-8643) | 2x Mini-SAS HD x4 (SFF-8643) | 2x Mini-SAS HD x4 (SFF-8643) | 4x Mini-SAS HD x4 (SFF-8643) |
Drive interface | SAS, SATA | SAS, SATA | SAS, SATA | SAS, SATA | SAS, SATA |
Drive type | HDD, SED, SSD | HDD, SSD | HDD, SED, SSD | HDD, SED, SSD | HDD, SED, SSD |
Hot-swap drives | Yes | Yes | Yes | Yes | Yes |
Max devices | 8 | 8 | 8 | 8 | 16 |
RAID levels | 0, 1, 10, 5, 50 | 0, 1, 10, 5, 50 | 0, 1, 10, 5, 50, 6, 60 | 0, 1, 10, 5, 50, 6, 60 | 0, 1, 10, 5, 50, 6, 60 |
JBOD mode | Yes | Yes | Yes | Yes | Yes |
Cache | None | 1GB (Standard) | 2GB (Standard) | 2GB (Standard) | 4GB or 8GB (Standard) |
CacheVault cache protection | No | No | Yes (Flash) | Yes (Flash) | Yes (Flash) |
Performance Accelerator (FastPath) | Yes | No | Yes | Yes | Yes |
SSD Caching (CacheCade Pro 2.0) | No | No | No | No | No |
SED support* | Yes | No | Yes | Yes | Yes |
* SAS HBAs support SEDs (self-encrypting drives) by using software on the server and simply passing SED commands through the HBA to the drives. SED support by RAID controllers is provided using the built-in MegaRAID SafeStore functionality of the adapter.
** The RAID 730-8i 1GB Cache adapter is not available in USA and Canada.
Feature | 430-8i | 430-16i | 1610-4P NVMe |
---|---|---|---|
Adapter type | HBA | HBA | NVMe switch |
Part number | 7Y37A01088 | 7Y37A01089 | 7Y37A01081 |
Form factor | PCIe low profile | PCIe low profile | PCIe HHHL |
Controller chip | LSI SAS3408 | LSI SAS3416 | Broadcom PEX9733 |
Broadcom equivalent | HBA 9400-8i | HBA 9400-16i | P310W-4P |
Host interface | PCIe 3.0x8 | PCIe 3.0x8 | PCIe 3.0x16 |
Port interface | 12 Gb SAS | 12 Gb SAS | PCIe NVMe |
Number of ports | 8 | 16 | 4 |
Port connectors | 2x Mini-SAS HD x4 (SFF-8643) | 4x Mini-SAS HD x4 (SFF-8643) | 4x Mini-SAS HD x4 (SFF-8643) |
Drive interface | SAS, SATA | SAS, SATA | NVMe |
Drive type | HDD, SSD, SED* | HDD, SSD, SED* | SSD |
Hot-swap drives | Yes | Yes | Yes |
Max devices | 8 | 16 | 4 |
RAID levels | No RAID | No RAID | None |
JBOD mode | Yes | Yes | Yes |
Cache | No | No | None |
CacheVault cache protection | No | No | No |
Performance Accelerator (FastPath) | No | No | No |
SSD Caching (CacheCade Pro 2.0) | No | No | No |
SED support* | Yes | Yes | No |
* SAS HBAs support SEDs (self-encrypting drives) by using software on the server and simply passing SED commands through the HBA to the drives. SED support by RAID controllers is provided using the built-in MegaRAID SafeStore functionality of the adapter.
For more information about the adapters see the product guides in the RAID adapters or HBA sections of the Lenovo Press web site:
https://lenovopress.com/servers/options/raid
https://lenovopress.com/servers/options/hba
Internal drive options
The following tables list the hard disk drive and solid-state drive options for the internal disk storage of the server.
2.5-inch hot-swap drives:
M.2 drives:
M.2 drive support: The use of M.2 drives requires an additional adapter as described in the M.2 drives subsection.
PCIe 4.0 NVMe drive support: When installed in this server, PCIe 4.0 NVMe drives will operate at PCIe 3.0 speeds.
Part number | Feature | Description | Maximum supported |
---|---|---|---|
2.5-inch hot-swap HDDs - 12 Gb SAS 10K | |||
7XB7A00024 | AULY | ThinkSystem 2.5" 300GB 10K SAS 12Gb Hot Swap 512n HDD | 16 |
7XB7A00025 | AULZ | ThinkSystem 2.5" 600GB 10K SAS 12Gb Hot Swap 512n HDD | 16 |
7XB7A00026 | AUM0 | ThinkSystem 2.5" 900GB 10K SAS 12Gb Hot Swap 512n HDD | 16 |
7XB7A00027 | AUM1 | ThinkSystem 2.5" 1.2TB 10K SAS 12Gb Hot Swap 512n HDD | 16 |
7XB7A00028 | AUM2 | ThinkSystem 2.5" 1.8TB 10K SAS 12Gb Hot Swap 512e HDD | 16 |
7XB7A00069 | B0YS | ThinkSystem 2.5" 2.4TB 10K SAS 12Gb Hot Swap 512e HDD | 16 |
2.5-inch hot-swap HDDs - 12 Gb SAS 15K | |||
7XB7A00021 | AULV | ThinkSystem 2.5" 300GB 15K SAS 12Gb Hot Swap 512n HDD | 16 |
7XB7A00022 | AULW | ThinkSystem 2.5" 600GB 15K SAS 12Gb Hot Swap 512n HDD | 16 |
7XB7A00023 | AULX | ThinkSystem 2.5" 900GB 15K SAS 12Gb Hot Swap 512e HDD | 16 |
2.5-inch hot-swap HDDs - 12 Gb NL SAS | |||
7XB7A00034 | AUM6 | ThinkSystem 2.5" 1TB 7.2K SAS 12Gb Hot Swap 512n HDD | 16 |
7XB7A00035 | AUM7 | ThinkSystem 2.5" 2TB 7.2K SAS 12Gb Hot Swap 512n HDD | 16 |
2.5-inch hot-swap SED HDDs - 12 Gb SAS 10K | |||
7XB7A00030 | AUM4 | ThinkSystem 2.5" 300GB 10K SAS 12Gb Hot Swap 512n HDD SED | 16 |
7XB7A00031 | AUM5 | ThinkSystem 2.5" 600GB 10K SAS 12Gb Hot Swap 512n HDD SED | 16 |
7XB7A00033 | B0YX | ThinkSystem 2.5" 1.2TB 10K SAS 12Gb Hot Swap 512n HDD SED | 16 |
Part number | Feature | Description | Maximum supported |
---|---|---|---|
2.5-inch hot-swap HDDs - 6 Gb NL SATA | |||
7XB7A00036 | AUUE | ThinkSystem 2.5" 1TB 7.2K SATA 6Gb Hot Swap 512n HDD | 16 |
7XB7A00037 | AUUJ | ThinkSystem 2.5" 2TB 7.2K SATA 6Gb Hot Swap 512e HDD | 16 |
Part number | Feature | Description | Maximum supported |
---|---|---|---|
2.5-inch hot-swap SSDs - 12 Gb SAS - Performance (10+ DWPD) | |||
4XB7A10219 | B4Y4 | ThinkSystem 2.5" SS530 400GB Performance SAS 12Gb Hot Swap SSD | 16 |
4XB7A10230 | B4Y5 | ThinkSystem 2.5" SS530 800GB Performance SAS 12Gb Hot Swap SSD | 16 |
4XB7A10231 | B4Y6 | ThinkSystem 2.5" SS530 1.6TB Performance SAS 12Gb Hot Swap SSD | 16 |
4XB7A10232 | B4Y7 | ThinkSystem 2.5" SS530 3.2TB Performance SAS 12Gb Hot Swap SSD | 16 |
7N47A00124 | AUMG | ThinkSystem 2.5" HUSMM32 400GB Performance SAS 12Gb Hot Swap SSD | 16 |
7N47A00125 | AUMH | ThinkSystem 2.5" HUSMM32 800GB Performance SAS 12Gb Hot Swap SSD | 16 |
7N47A00126 | AVRB | ThinkSystem 2.5" HUSMM32 1.6TB Performance SAS 12Gb Hot Swap SSD | 16 |
2.5-inch hot-swap SSDs - 12 Gb SAS - Mainstream (3-5 DWPD) | |||
4XB7A17062 | B8HU | ThinkSystem 2.5" PM1645a 800GB Mainstream SAS 12Gb Hot Swap SSD | 16 |
4XB7A17063 | B8J4 | ThinkSystem 2.5" PM1645a 1.6TB Mainstream SAS 12Gb Hot Swap SSD | 16 |
4XB7A17064 | B8JD | ThinkSystem 2.5" PM1645a 3.2TB Mainstream SAS 12Gb Hot Swap SSD | 16 |
4XB7A17065 | B8JA | ThinkSystem 2.5" PM1645a 6.4TB Mainstream SAS 12Gb Hot Swap SSD | 16 |
4XB7A13653 | B4A0 | ThinkSystem 2.5" PM1645 800GB Mainstream SAS 12Gb Hot Swap SSD | 16 |
4XB7A13654 | B4A1 | ThinkSystem 2.5" PM1645 1.6TB Mainstream SAS 12Gb Hot Swap SSD | 16 |
4XB7A13655 | B4A2 | ThinkSystem 2.5" PM1645 3.2TB Mainstream SAS 12Gb Hot Swap SSD | 16 |
7N47A00117 | AUMC | ThinkSystem 2.5" PM1635a 400GB Mainstream SAS 12Gb Hot Swap SSD | 16 |
7N47A00118 | AUMD | ThinkSystem 2.5" PM1635a 800GB Mainstream SAS 12Gb Hot Swap SSD | 16 |
7N47A00119 | AVRG | ThinkSystem 2.5" PM1635a 1.6TB Mainstream SAS 12Gb Hot Swap SSD | 16 |
7N47A00120 | AVRJ | ThinkSystem 2.5" PM1635a 3.2TB Mainstream SAS 12Gb Hot Swap SSD | 16 |
2.5-inch hot-swap SSDs - 12 Gb SAS - Entry / Capacity (<3 DWPD) | |||
4XB7A38175 | B91A | ThinkSystem 2.5" PM1643a 960GB Entry SAS 12Gb Hot Swap SSD | 16 |
4XB7A38176 | B91B | ThinkSystem 2.5" PM1643a 1.92TB Entry SAS 12Gb Hot Swap SSD | 16 |
4XB7A17054 | B91C | ThinkSystem 2.5" PM1643a 3.84TB Entry SAS 12Gb Hot Swap SSD | 16 |
4XB7A17055 | B91D | ThinkSystem 2.5" PM1643a 7.68TB Entry SAS 12Gb Hot Swap SSD | 16 |
4XB7A17056 | BC4R | ThinkSystem 2.5" PM1643a 15.36TB Entry SAS 12Gb Hot Swap SSD | 16 |
4XB7A13645 | B4A7 | ThinkSystem 2.5" PM1643 3.84TB Capacity SAS 12Gb Hot Swap SSD | 16 |
4XB7A13646 | B4A6 | ThinkSystem 2.5" PM1643 7.68TB Capacity SAS 12Gb Hot Swap SSD | 16 |
7N47A00121 | AUMK | ThinkSystem 2.5" PM1633a 3.84TB Capacity SAS 12Gb Hot Swap SSD | 16 |
7N47A00122 | AUML | ThinkSystem 2.5" PM1633a 7.68TB Capacity SAS 12Gb Hot Swap SSD | 16 |
7N47A00123 | B116 | ThinkSystem 2.5" PM1633a 15.36TB Capacity SAS 12Gb Hot Swap SSD | 16 |
2.5-inch hot-swap SED SSDs - 12 Gb SAS - Performance (10+ DWPD) | |||
7SD7A05754 | B11P | ThinkSystem 2.5" HUSMM32 400GB Performance SAS 12Gb Hot Swap SSD FIPS | 16 |
7SD7A05753 | B11Q | ThinkSystem 2.5" HUSMM32 800GB Performance SAS 12Gb Hot Swap SSD FIPS | 16 |
7SD7A05752 | B11R | ThinkSystem 2.5" HUSMM32 1.6TB Performance SAS 12Gb Hot Swap SSD FIPS | 16 |
2.5-inch hot-swap SED SSDs - 12 Gb SAS - Mainstream (3-5 DWPD) | |||
4XB7A17069 | B6K5 | ThinkSystem 2.5" SS530 400GB Mainstream SAS 12Gb Hot Swap SSD SED | 16 |
Part number | Feature | Description | Maximum supported |
---|---|---|---|
2.5-inch hot-swap SSDs - 6 Gb SATA - Mainstream (3-5 DWPD) | |||
4XB7A17087 | B8J1 | ThinkSystem 2.5" 5300 240GB Mainstream SATA 6Gb Hot Swap SSD | 16 |
4XB7A17088 | B8HY | ThinkSystem 2.5" 5300 480GB Mainstream SATA 6Gb Hot Swap SSD | 16 |
4XB7A17089 | B8J6 | ThinkSystem 2.5" 5300 960GB Mainstream SATA 6Gb Hot Swap SSD | 16 |
4XB7A17090 | B8JE | ThinkSystem 2.5" 5300 1.92TB Mainstream SATA 6Gb Hot Swap SSD | 16 |
4XB7A17091 | B8J7 | ThinkSystem 2.5" 5300 3.84TB Mainstream SATA 6Gb Hot Swap SSD | 16 |
4XB7A13633 | B49L | ThinkSystem 2.5" Intel S4610 240GB Mainstream SATA 6Gb Hot Swap SSD | 16 |
4XB7A13634 | B49M | ThinkSystem 2.5" Intel S4610 480GB Mainstream SATA 6Gb Hot Swap SSD | 16 |
4XB7A13635 | B49N | ThinkSystem 2.5" Intel S4610 960GB Mainstream SATA 6Gb Hot Swap SSD | 16 |
4XB7A13636 | B49P | ThinkSystem 2.5" Intel S4610 1.92TB Mainstream SATA 6Gb Hot Swap SSD | 16 |
4XB7A13637 | B49Q | ThinkSystem 2.5" Intel S4610 3.84TB Mainstream SATA 6Gb Hot Swap SSD | 16 |
4XB7A10237 | B488 | ThinkSystem 2.5" 5200 240GB Mainstream SATA 6Gb Hot Swap SSD | 16 |
4XB7A10238 | B489 | ThinkSystem 2.5" 5200 480GB Mainstream SATA 6Gb Hot Swap SSD | 16 |
4XB7A10239 | B48A | ThinkSystem 2.5" 5200 960GB Mainstream SATA 6Gb Hot Swap SSD | 16 |
4XB7A10240 | B48B | ThinkSystem 2.5" 5200 1.92TB Mainstream SATA 6Gb Hot Swap SSD | 16 |
4XB7A10241 | B48C | ThinkSystem 2.5" 5200 3.84TB Mainstream SATA 6Gb Hot Swap SSD | 16 |
7SD7A05723 | B0ZP | ThinkSystem 2.5" Intel S4600 240GB Mainstream SATA 6Gb Hot Swap SSD | 16 |
7SD7A05722 | B0ZQ | ThinkSystem 2.5" Intel S4600 480GB Mainstream SATA 6Gb Hot Swap SSD | 16 |
7SD7A05721 | B0ZR | ThinkSystem 2.5" Intel S4600 960GB Mainstream SATA 6Gb Hot Swap SSD | 16 |
7SD7A05720 | B0ZS | ThinkSystem 2.5" Intel S4600 1.92TB Mainstream SATA 6Gb Hot Swap SSD | 16 |
7SD7A05765 | B10W | ThinkSystem 2.5" 5100 240GB Mainstream SATA 6Gb Hot Swap SSD | 16 |
7SD7A05764 | B10X | ThinkSystem 2.5" 5100 480GB Mainstream SATA 6Gb Hot Swap SSD | 16 |
7SD7A05763 | B10Y | ThinkSystem 2.5" 5100 960GB Mainstream SATA 6Gb Hot Swap SSD | 16 |
7SD7A05762 | B10Z | ThinkSystem 2.5" 5100 1.92TB Mainstream SATA 6Gb Hot Swap SSD | 16 |
7SD7A05761 | B110 | ThinkSystem 2.5" 5100 3.84TB Mainstream SATA 6Gb Hot Swap SSD | 16 |
2.5-inch hot-swap SSDs - 6 Gb SATA - Entry (<3 DWPD) | |||
4XB7A38271 | BCTC | ThinkSystem 2.5" Multi Vendor 240GB Entry SATA 6Gb Hot Swap SSD | 16 |
4XB7A38272 | BCTD | ThinkSystem 2.5" Multi Vendor 480GB Entry SATA 6Gb Hot Swap SSD | 16 |
4XB7A38273 | BCTE | ThinkSystem 2.5" Multi Vendor 960GB Entry SATA 6Gb Hot Swap SSD | 16 |
4XB7A38274 | BCTF | ThinkSystem 2.5" Multi Vendor 1.92TB Entry SATA 6Gb Hot Swap SSD | 16 |
4XB7A38275 | BCTG | ThinkSystem 2.5" Multi Vendor 3.84TB Entry SATA 6Gb Hot Swap SSD | 16 |
4XB7A17075 | B8HV | ThinkSystem 2.5" 5300 240GB Entry SATA 6Gb Hot Swap SSD | 16 |
4XB7A17076 | B8JM | ThinkSystem 2.5" 5300 480GB Entry SATA 6Gb Hot Swap SSD | 16 |
4XB7A17077 | B8HP | ThinkSystem 2.5" 5300 960GB Entry SATA 6Gb Hot Swap SSD | 16 |
4XB7A17078 | B8J5 | ThinkSystem 2.5" 5300 1.92TB Entry SATA 6Gb Hot Swap SSD | 16 |
4XB7A17079 | B8JP | ThinkSystem 2.5" 5300 3.84TB Entry SATA 6Gb Hot Swap SSD | 16 |
4XB7A17080 | B8J2 | ThinkSystem 2.5" 5300 7.68TB Entry SATA 6Gb Hot Swap SSD | 16 |
4XB7A38185 | B9AC | ThinkSystem 2.5" 5210 960GB Entry SATA 6Gb Hot Swap QLC SSD | 16 |
4XB7A38144 | B7EW | ThinkSystem 2.5" 5210 1.92TB Entry SATA 6Gb Hot Swap QLC SSD | 16 |
4XB7A38145 | B7EX | ThinkSystem 2.5" 5210 3.84TB Entry SATA 6Gb Hot Swap QLC SSD | 16 |
4XB7A38146 | B7EY | ThinkSystem 2.5" 5210 7.68TB Entry SATA 6Gb Hot Swap QLC SSD | 16 |
4XB7A10247 | B498 | ThinkSystem 2.5" Intel S4510 240GB Entry SATA 6Gb Hot Swap SSD | 16 |
4XB7A10248 | B499 | ThinkSystem 2.5" Intel S4510 480GB Entry SATA 6Gb Hot Swap SSD | 16 |
4XB7A10249 | B49A | ThinkSystem 2.5" Intel S4510 960GB Entry SATA 6Gb Hot Swap SSD | 16 |
4XB7A13622 | B49B | ThinkSystem 2.5" Intel S4510 1.92TB Entry SATA 6Gb Hot Swap SSD | 16 |
4XB7A13623 | B49C | ThinkSystem 2.5" Intel S4510 3.84TB Entry SATA 6Gb Hot Swap SSD | 16 |
4XB7A10195 | B34H | ThinkSystem 2.5" PM883 240GB Entry SATA 6Gb Hot Swap SSD | 16 |
4XB7A10196 | B34J | ThinkSystem 2.5" PM883 480GB Entry SATA 6Gb Hot Swap SSD | 16 |
4XB7A10197 | B34K | ThinkSystem 2.5" PM883 960GB Entry SATA 6Gb Hot Swap SSD | 16 |
4XB7A10198 | B34L | ThinkSystem 2.5" PM883 1.92TB Entry SATA 6Gb Hot Swap SSD | 16 |
4XB7A10199 | B34M | ThinkSystem 2.5" PM883 3.84TB Entry SATA 6Gb Hot Swap SSD | 16 |
4XB7A10200 | B4D2 | ThinkSystem 2.5" PM883 7.68TB Entry SATA 6Gb Hot Swap SSD | 16 |
7SD7A05742 | B0YY | ThinkSystem 2.5" Intel S4500 240GB Entry SATA 6Gb Hot Swap SSD | 16 |
7SD7A05741 | B0YZ | ThinkSystem 2.5" Intel S4500 480GB Entry SATA 6Gb Hot Swap SSD | 16 |
7SD7A05740 | B0Z0 | ThinkSystem 2.5" Intel S4500 960GB Entry SATA 6Gb Hot Swap SSD | 16 |
7SD7A05739 | B0Z1 | ThinkSystem 2.5" Intel S4500 1.92TB Entry SATA 6Gb Hot Swap SSD | 16 |
7SD7A05738 | B0Z2 | ThinkSystem 2.5" Intel S4500 3.84TB Entry SATA 6Gb Hot Swap SSD | 16 |
7N47A00111 | AUUQ | ThinkSystem 2.5" PM863a 240GB Entry SATA 6Gb Hot Swap SSD | 16 |
7N47A00112 | AUM9 | ThinkSystem 2.5" PM863a 480GB Entry SATA 6Gb Hot Swap SSD | 16 |
7N47A00113 | AVCZ | ThinkSystem 2.5" PM863a 960GB Entry SATA 6Gb Hot Swap SSD | 16 |
7N47A00114 | AVRC | ThinkSystem 2.5" PM863a 1.92TB Entry SATA 6Gb Hot Swap SSD | 16 |
4XB7A10153 | B2X2 | ThinkSystem 2.5" 5200 480GB Entry SATA 6Gb Hot Swap SSD | 16 |
4XB7A10154 | B2X3 | ThinkSystem 2.5" 5200 960GB Entry SATA 6Gb Hot Swap SSD | 16 |
4XB7A10155 | B2X4 | ThinkSystem 2.5" 5200 1.92TB Entry SATA 6Gb Hot Swap SSD | 16 |
4XB7A10156 | B2X5 | ThinkSystem 2.5" 5200 3.84TB Entry SATA 6Gb Hot Swap SSD | 16 |
4XB7A10157 | B2X6 | ThinkSystem 2.5" 5200 7.68TB Entry SATA 6Gb Hot Swap SSD | 16 |
4XB7A08502 | B10N | ThinkSystem 2.5" 5100 480GB Entry SATA 6Gb Hot Swap SSD | 16 |
4XB7A08503 | B10P | ThinkSystem 2.5" 5100 960GB Entry SATA 6Gb Hot Swap SSD | 16 |
4XB7A08504 | B10Q | ThinkSystem 2.5" 5100 1.92TB Entry SATA 6Gb Hot Swap SSD | 16 |
4XB7A08505 | B10R | ThinkSystem 2.5" 5100 3.84TB Entry SATA 6Gb Hot Swap SSD | 16 |
7N47A00099 | AUM8 | ThinkSystem 2.5" Intel S3520 240GB Entry SATA 6Gb Hot Swap SSD | 16 |
7N47A00100 | AUUZ | ThinkSystem 2.5" Intel S3520 480GB Entry SATA 6Gb Hot Swap SSD | 16 |
Part number | Feature | Description | Maximum supported |
---|---|---|---|
2.5-inch SSDs - PCIe 4.0 NVMe - Mainstream (3-5 DWPD) | |||
4XB7A17152 | BCFV | ThinkSystem U.2 Intel P5600 1.6TB Mainstream NVMe PCIe 4.0 x4 Hot Swap SSD | 8 |
4XB7A17153 | BCFR | ThinkSystem U.2 Intel P5600 3.2TB Mainstream NVMe PCIe 4.0 x4 Hot Swap SSD | 8 |
4XB7A17154 | BCFS | ThinkSystem U.2 Intel P5600 6.4TB Mainstream NVMe PCIe 4.0 x4 Hot Swap SSD | 8 |
4XB7A64175 | BE03 | ThinkSystem U.3 Kioxia CM6-V 800GB Mainstream NVMe PCIe 4.0 x4 Hot Swap SSD | 8 |
4XB7A17112 | B96Z | ThinkSystem U.3 Kioxia CM6-V 1.6TB Mainstream NVMe PCIe4.0 x4 Hot Swap SSD | 8 |
4XB7A17113 | B96T | ThinkSystem U.3 Kioxia CM6-V 3.2TB Mainstream NVMe PCIe4.0 x4 Hot Swap SSD | 8 |
4XB7A17114 | B96P | ThinkSystem U.3 Kioxia CM6-V 6.4TB Mainstream NVMe PCIe4.0 x4 Hot Swap SSD | 8 |
2.5-inch SSDs - PCIe 4.0 NVMe - Entry (<3 DWPD) | |||
4XB7A17145 | BCFT | ThinkSystem U.2 Intel P5500 1.92TB Entry NVMe PCIe 4.0 x4 Hot Swap SSD | 8 |
4XB7A17146 | BCFW | ThinkSystem U.2 Intel P5500 3.84TB Entry NVMe PCIe 4.0 x4 Hot Swap SSD | 8 |
4XB7A17147 | BCFU | ThinkSystem U.2 Intel P5500 7.68TB Entry NVMe PCIe 4.0 x4 Hot Swap SSD | 8 |
Part number | Feature | Description | Maximum supported |
---|---|---|---|
2.5-inch SSDs - PCIe 3.0 NVMe - Performance (10+ DWPD) | |||
7N47A00081 | AUMJ | ThinkSystem U.2 Intel Optane P4800X 375GB Performance NVMe PCIe 3.0 x4 Hot Swap SSD | 8 |
7N47A00083 | B2ZJ | ThinkSystem U.2 Intel Optane P4800X 750GB Performance NVMe PCIe 3.0 x4 Hot Swap SSD | 8 |
7XB7A05923 | AWG6 | ThinkSystem U.2 PX04PMB 800GB Performance NVMe PCIe 3.0 x4 Hot Swap SSD | 8 |
7XB7A05922 | AWG7 | ThinkSystem U.2 PX04PMB 1.6TB Performance NVMe PCIe 3.0 x4 Hot Swap SSD | 8 |
2.5-inch SSDs - PCIe 3.0 NVMe - Mainstream (3-5 DWPD) | |||
4XB7A13936 | B589 | ThinkSystem U.2 Intel P4610 1.6TB Mainstream NVMe PCIe3.0 x4 Hot Swap SSD | 8 |
4XB7A13937 | B58A | ThinkSystem U.2 Intel P4610 3.2TB Mainstream NVMe PCIe3.0 x4 Hot Swap SSD | 8 |
4XB7A13938 | B58B | ThinkSystem U.2 Intel P4610 6.4TB Mainstream NVMe PCIe3.0 x4 Hot Swap SSD | 8 |
4XB7A08516 | B21W | ThinkSystem U.2 Toshiba CM5-V 800GB Mainstream NVMe PCIe 3.0 x4 Hot Swap SSD | 8 |
4XB7A08517 | B21X | ThinkSystem U.2 Toshiba CM5-V 1.6TB Mainstream NVMe PCIe 3.0 x4 Hot Swap SSD | 8 |
4XB7A08518 | B21Y | ThinkSystem U.2 Toshiba CM5-V 3.2TB Mainstream NVMe PCIe 3.0 x4 Hot Swap SSD | 8 |
4XB7A08519 | B2XJ | ThinkSystem U.2 Toshiba CM5-V 6.4TB Mainstream NVMe PCIe 3.0 x4 Hot Swap SSD | 8 |
7N47A00095 | AUUY | ThinkSystem U.2 PX04PMB 960GB Mainstream NVMe PCIe 3.0 x4 Hot Swap SSD | 8 |
7N47A00096 | AUMF | ThinkSystem U.2 PX04PMB 1.92TB Mainstream NVMe PCIe 3.0 x4 Hot Swap SSD | 8 |
7SD7A05772 | B11J | ThinkSystem U.2 Intel P4600 1.6TB Mainstream NVMe PCIe3.0 x4 Hot Swap SSD | 8 |
7SD7A05771 | B11K | ThinkSystem U.2 Intel P4600 3.2TB Mainstream NVMe PCIe3.0 x4 Hot Swap SSD | 8 |
2.5-inch SSDs - PCIe 3.0 NVMe - Entry (<3 DWPD) | |||
4XB7A10202 | B58F | ThinkSystem U.2 Intel P4510 1.0TB Entry NVMe PCIe3.0 x4 Hot Swap SSD | 8 |
4XB7A10204 | B58G | ThinkSystem U.2 Intel P4510 2.0TB Entry NVMe PCIe3.0 x4 Hot Swap SSD | 8 |
4XB7A10205 | B58H | ThinkSystem U.2 Intel P4510 4.0TB Entry NVMe PCIe3.0 x4 Hot Swap SSD | 8 |
4XB7A10175 | B34N | ThinkSystem U.2 PM983 1.92TB Entry NVMe PCIe 3.0 x4 Hot Swap SSD | 8 |
4XB7A10176 | B34P | ThinkSystem U.2 PM983 3.84TB Entry NVMe PCIe 3.0 x4 Hot Swap SSD | 8 |
4XB7A10177 | B4D3 | ThinkSystem U.2 PM983 7.68TB Entry NVMe PCIe3.0 x4 Hot Swap SSD | 8 |
7N47A00984 | AUV0 | ThinkSystem U.2 PM963 1.92TB Entry NVMe PCIe 3.0 x4 Hot Swap SSD | 8 |
7N47A00985 | AUUU | ThinkSystem U.2 PM963 3.84TB Entry NVMe PCIe 3.0 x4 Hot Swap SSD | 8 |
7SD7A05779 | B11C | ThinkSystem U.2 Intel P4500 1.0TB Entry NVMe PCIe3.0 x4 Hot Swap SSD | 8 |
7SD7A05778 | B11D | ThinkSystem U.2 Intel P4500 2.0TB Entry NVMe PCIe3.0 x4 Hot Swap SSD | 8 |
7SD7A05777 | B11E | ThinkSystem U.2 Intel P4500 4.0TB Entry NVMe PCIe3.0 x4 Hot Swap SSD | 8 |
Note: NVMe PCIe SSDs support surprise hot removal and hot insertion, provided the operating system supports PCIe SSD hot-swap.
Part number | Feature | Description | Maximum supported |
---|---|---|---|
M.2 SSDs - 6 Gb SATA - Entry (<3 DWPD) | |||
7N47A00129 | AUUL | ThinkSystem M.2 32GB SATA 6Gbps Non-Hot Swap SSD | 2 |
7N47A00130 | AUUV | ThinkSystem M.2 128GB SATA 6Gbps Non-Hot Swap SSD | 2 |
4XB7A14049 | B5S4 | ThinkSystem M.2 5100 240GB SATA 6Gbps Non-Hot Swap SSD | 2 |
7SD7A05703 | B11V | ThinkSystem M.2 5100 480GB SATA 6Gbps Non-Hot Swap SSD | 2 |
4XB7A17071 | B8HS | ThinkSystem M.2 5300 240GB SATA 6Gbps Non-Hot Swap SSD | 2 |
4XB7A17073 | B919 | ThinkSystem M.2 5300 480GB SATA 6Gbps Non-Hot Swap SSD | 2 |
Internal backup units
The server does not supports any internal backup units, such as tape drives or RDX drives.
Optical drives
The server supports the external USB optical drive listed in the following table.
Part number | Feature code | Description |
---|---|---|
7XA7A05926 | AVV8 | ThinkSystem External USB DVD RW Optical Disk Drive |
The drive is based on the Lenovo Slim DVD Burner DB65 drive and supports the following formats: DVD-RAM, DVD-RW, DVD+RW, DVD+R, DVD-R, DVD-ROM, DVD-R DL, CD-RW, CD-R, CD-ROM.
I/O expansion options
The server supports up to 9 PCIe 3.0 slots, plus a slot for the LOM adapter and a slot for the M.2 adapter.
Six PCIe 3.0 slots (1, 2, 8, 9, 10, 11) are on the system board and three slots (slots 3-5) are through a riser card. A riser card is standard on some models and optional on others. The LOM slot (slot 7) is also vertically mounted on the system board. All slots are available with two processors.
The PCIe slots are as follows:
- Slot 1: PCIe 3.0 x16 (low profile) (CPU 2)
- Slot 2: PCIe 3.0 x8 (low profile, x8 physical slot) (CPU 2)
- Slot 3-5: Riser card slots (see below) (CPU 2)
- Slot 6: PCIe 2.0 x2 dedicated to M.2 adapter and drives
- Slot 7: Dedicated to Ethernet LOM phy adapter (CPU 1)
- Slot 8: PCIe 3.0 x8 (low profile, x8 physical slot) (CPU 1)
- Slot 9: PCIe 3.0 x8 (low profile, x8 physical slot) (CPU 1)
- Slot 10: PCIe 3.0 x8 (low profile, x8 physical slot) (CPU 1)
- Slot 11: PCIe 3.0 x16 (low profile) (CPU 1)
The locations of the slots are shown in the following figure.
Figure 13. SR850 slots
Note: Slot 6 is an internal slot for the M.2 adapter as described in the M.2 drives section.
Slots 3-5 are implemented using a riser card, and the SR850 supports three different riser cards as listed in the following table.
The following table lists the ordering information for the riser cards.
Part number |
Feature code |
Description | Maximum supported |
---|---|---|---|
7C57A03950 | AUR4 | ThinkSystem SR850/SR860 x8/x8/x8 PCIe FH Riser 1 Kit | 1 |
7C57A03951 | AUR7 | ThinkSystem SR850/SR860 x8/x8/x8ML2 PCIe FH Riser 1 Kit | 1 |
7C57A03952 | AURB | ThinkSystem SR850/SR860 x8/x16ML2 PCIe FH Riser 1 Kit | 1 |
The riser cards listed in the table have the following slots:
- x8/x8/x8 PCIe FH Riser:
- Slot 3: PCIe 3.0 x8 FHHL (x16 physical slot)
- Slot 4: PCIe 3.0 x8 FHHL (x16 physical slot)
- Slot 5: PCIe 3.0 x8 FHHL (x16 physical slot)
- x8/x8/x8ML2 PCIe FH
- Slot 3: PCIe 3.0 x8 FHHL (x16 physical slot)
- Slot 4: PCIe 3.0 x8 FHHL (x16 physical slot)
- Slot 5: PCIe 3.0 x8 ML2 FHHL (x8 physical slot)
- x8/x16ML2 PCIe FH Riser
- Slot 3: PCIe 3.0 x8 FHHL (x16 physical slot)
- Slot 4: None
- Slot 5: PCIe 3.0 x16 ML2 FHHL (x16 physical slot)
Network adapters
The SR850 has integrated Intel Ethernet Connection X722 technology which can provide up to four 1/10GbE network ports via an optional LOM card. The X722 has the following features:
- Integrated into the Intel PCH chipset
- Supports 1GbE or 10GbE connections, depending on the selected LOM Phy adapter
- Offers VXLAN/NVGRE hardware offloads
- Supports VMDq and SR-IOV for advanced virtualization
- Supports iWarp RDMA
To provide connectivity to the X722, the SR850 supports six different LOM (LAN on Motherboard) cards which provide the Ethernet PHY function. Only 1 LOM card can be installed. See Figure 3 for the location of the LOM slot.
The LOM card supports NC-SI to allow the network connection to be shared between the operating system and the XClarity Controller (XCC) management module. The LOM also supports Wake-on-LAN (WOL).
For more information about the X722 controller, see the Lenovo Press product guide:
http://lenovopress.com/LP0654-intel-x722-integrated-controller
The following table lists the supported LOM cards.
Note: None of the LOM cards listed in the table support speeds lower than 1 Gbps.
Part number |
Feature code |
Description | Ports | Slots supported |
Maximum supported |
---|---|---|---|---|---|
Gigabit Ethernet | |||||
7ZT7A00544 | AUKG | ThinkSystem 1Gb 2-port RJ45 LOM | 2x RJ45 | 7 | 1 |
7ZT7A00545 | AUKH | ThinkSystem 1Gb 4-port RJ45 LOM | 4x RJ45 | 7 | 1 |
10 Gb Ethernet | |||||
7ZT7A00546 | AUKJ | ThinkSystem 10Gb 2-port SFP+ LOM | 2x SFP+ bays | 7 | 1 |
7ZT7A00547 | AUKK | ThinkSystem 10Gb 4-port SFP+ LOM | 4x SFP+ bays | 7 | 1 |
7ZT7A00548 | AUKL | ThinkSystem 10Gb 2-port Base-T LOM | 2x RJ45 (10GBASE-T) | 7 | 1 |
7ZT7A00549 | AUKM | ThinkSystem 10Gb 4-port Base-T LOM | 4x RJ45 (10GBASE-T) | 7 | 1 |
The SR850 also supports an ML2 card provided a suitable ML2 riser card is installed (see the I/O expansion options section for details). The ML2 card supports NC-SI and WOL. The following table lists the supported ML2 adapters.
VFA5.2 and FCoE support: ThinkSystem servers do not support Features on Demand, so the Emulex VFA5.2 ML2 Dual Port 10GbE SFP+ Adapter, 00AG560, cannot be upgraded to FCoE support. If you need FCoE or iSCSI support use 01CV770 instead.
Part number |
Feature code |
Description | Bus width | Slots supported |
Maximum supported |
---|---|---|---|---|---|
Gigabit Ethernet | |||||
7ZT7A00536 | AUKW | ThinkSystem Intel I350-T4 ML2 1Gb 4-Port RJ45 Ethernet Adapter | PCIe 3.0 x8 | 5 | 1 |
10 Gb Ethernet | |||||
00JY940 | ATRH | Intel X710-DA2 ML2 2x10GbE SFP+ Adapter | PCIe 3.0 x8 | 5 | 1 |
7ZT7A00497 | AUKQ | ThinkSystem Broadcom 57416 10GBASE-T 2-Port ML2 Ethernet Adapter | PCIe 3.0 x8 | 5 | 1 |
00AG560** | AT7U | Emulex VFA5.2 ML2 Dual Port 10GbE SFP+ Adapter | PCIe 3.0 x8 | 5 | 1 |
01CV770 | AU7Z | Emulex VFA5.2 ML2 2x10 GbE SFP+ Adapter and FCoE/iSCSI SW | PCIe 3.0 x8 | 5 | 1 |
25 Gb Ethernet | |||||
7ZT7A00507 | AUKU | ThinkSystem Mellanox ConnectX-4 Lx 10/25GbE SFP28 2-Port ML2 Ethernet Adapter | PCIe 3.0 x8 | 5 | 1 |
00MN990 | ATZR | Mellanox ConnectX-4 Lx 10/25GbE SFP28 1-port ML2 Adapter | PCIe 3.0 x8 | 5 | 1 |
InfiniBand | |||||
7ZT7A00501 | AUKR | ThinkSystem Mellanox ConnectX-3 Pro ML2 FDR 2-Port QSFP VPI Adapter | PCIe 3.0 x8 | 5 | 1 |
* ThinkSystem servers do not support Features on Demand, so the Emulex VFA5.2 ML2 Dual Port 10GbE SFP+ Adapter, 00AG560, cannot be upgraded to FCoE support. If you need FCoE or iSCSI support use 01CV770 instead.
The following table lists additional supported network adapters that can be installed in the regular PCIe slots.
VFA5.2 and FCoE support: ThinkSystem servers do not support Features on Demand, so the Emulex VFA5.2 2x10 GbE SFP+ PCIe Adapter, 00AG570, cannot be upgraded to FCoE support. If you need FCoE or iSCSI support use 00AG580 instead.
Part number |
Feature code |
Description | Slots supported |
Maximum supported |
---|---|---|---|---|
Gigabit Ethernet | ||||
7ZT7A00533 | AUZZ | ThinkSystem I350-F1 PCIe 1Gb 1-Port SFP Ethernet Adapter | 1-5, 8, 9, 11 | 8 |
7ZT7A00534 | AUZY | ThinkSystem I350-T2 PCIe 1Gb 2-Port RJ45 Ethernet Adapter | 1-5, 8, 9, 11 | 8 |
7ZT7A00535 | AUZW | ThinkSystem I350-T4 PCIe 1Gb 4-Port RJ45 Ethernet Adapter | 1-5, 8, 9, 11 | 8 |
7ZT7A00482 | AUZX | ThinkSystem Broadcom 5720 1GbE RJ45 2-Port PCIe Ethernet Adapter | 1-5, 8, 9, 11 | 8 |
7ZT7A00484 | AUZV | ThinkSystem Broadcom 5719 1GbE RJ45 4-Port PCIe Ethernet Adapter | 1-5, 8, 9, 11 | 8 |
10 Gb Ethernet - 10GBase-T | ||||
7ZT7A00496 | AUKP | ThinkSystem Broadcom 57416 10GBASE-T 2-Port PCIe Ethernet Adapter | 1-5, 8, 9, 11 | 8 |
00MM860 | ATPX | Intel X550-T2 Dual Port 10GBase-T Adapter | 1-5, 8, 9, 11 | 8 |
4XC7A08225 | B31G | ThinkSystem QLogic QL41134 PCIe 10Gb 4-Port Base-T Ethernet Adapter | 1-5, 8, 9, 11 | 8 |
10 Gb Ethernet - SFP+ | ||||
7ZT7A00537 | AUKX | ThinkSystem X710-DA2 PCIe 10Gb 2-Port SFP+ Ethernet Adapter | 1-5, 8, 9, 11 | 5† |
7ZT7A00493 | AUKN | ThinkSystem Emulex OCe14104B-NX PCIe 10Gb 4-Port SFP+ Ethernet Adapter | 3, 4, 5 | 3 |
00AG570* | AT7S | Emulex VFA5.2 2x10 GbE SFP+ PCIe Adapter | 1-5, 8, 9, 11 | 8 |
00AG580 | AT7T | Emulex VFA5.2 2x10 GbE SFP+ Adapter and FCoE/iSCSI SW | 1-5, 8, 9, 11 | 8 |
25 Gb Ethernet | ||||
4XC7A08270 | B652 | ThinkSystem Marvell QL41232 10/25GbE SFP28 2-Port PCIe Ethernet Adapter | 1-5, 8, 9, 11 | 8 |
4XC7A08228 | B21R | ThinkSystem QLogic QL41262 10/25GbE SFP28 2-Port PCIe Ethernet Adapter | 1-5, 8, 9, 11 | 8 |
7XC7A05523 | B0WY | ThinkSystem Intel XXV710-DA2 10/25GbE SFP28 2-Port PCIe Ethernet Adapter | 1-5, 8, 9, 11 | 5† |
7ZT7A00505 | AUKS | ThinkSystem Broadcom 57412 25GbE SFP28 1-Port PCIe Ethernet Adapter | 1-5, 8, 9, 11 | 8 |
4XC7A08238 | B5T0 | ThinkSystem Broadcom 57414 10/25GbE SFP28 2-port PCIe Ethernet Adapter | 1-5, 8, 9, 11 | 8 |
01GR250 | AUAJ | Mellanox ConnectX-4 Lx 10/25GbE SFP28 2-port PCIe Ethernet Adapter | 1-5, 8, 9, 11 | 8 |
4XC7A08229 | B31C | ThinkSystem Mellanox ConnectX-5 Ex 25/40GbE 2-port Low-Latency Adapter | 11, 1 | 2 |
40 Gb Ethernet | ||||
00MM950 | ATRN | Mellanox ConnectX-4 Lx 1x40GbE QSFP+ Adapter | 1-5, 8, 9, 11 | 8 |
7ZT7A00500 | AUVG | ThinkSystem Mellanox ConnectX-4 PCIe FDR 2-Port QSFP VPI Adapter | 1-5, 8, 9, 11 | 8 |
4XC7A08229 | B31C | ThinkSystem Mellanox ConnectX-5 Ex 25/40GbE 2-port Low-Latency Adapter | 11, 1 | 2 |
100 Gb Ethernet | ||||
00KH924 | ASWQ | Mellanox ConnectX-4 1x100GbE/EDR IB QSFP28 VPI Adapter | 11, 1 | 2 |
00MM960 | ATRP | Mellanox ConnectX-4 2x100GbE/EDR IB QSFP28 VPI Adapter | 11, 1 | 2 |
InfiniBand | ||||
7ZT7A00500 | AUVG | ThinkSystem Mellanox ConnectX-4 PCIe FDR 2-Port QSFP VPI Adapter | 1-5, 8, 9, 11 | 8 |
00KH924 | ASWQ | Mellanox ConnectX-4 1x100GbE/EDR IB QSFP28 VPI Adapter | 11, 1 | 2 |
00MM960 | ATRP | Mellanox ConnectX-4 2x100GbE/EDR IB QSFP28 VPI Adapter | 11, 1 | 2 |
4C57A14178 | B4RA | ThinkSystem Mellanox ConnectX-6 HDR100/100GbE QSFP56 2-port PCIe VPI Adapter | 1 | 1 |
4C57A14177 | B4R9 | ThinkSystem Mellanox ConnectX-6 HDR100/100GbE QSFP56 1-port PCIe VPI Adapter | 1 | 1 |
Omni-Path Architecture (OPA) | ||||
00WE023 | AU0A | Intel OPA 100 Series Single-port PCIe 3.0 x8 HFA | 1-5, 8, 9, 11 | 8 |
00WE027 | AU0B | Intel OPA 100 Series Single-port PCIe 3.0 x16 HFA | 11, 1 | 2 |
* ThinkSystem servers do not support Features on Demand, so the Emulex VFA5.2 2x10 GbE SFP+ PCIe Adapter, 00AG570, cannot be upgraded to FCoE support. If you need FCoE or iSCSI support use 00AG580 instead.
† Support for the X710-DA2 and XXV710-DA2 adapters is limited to 5 adapters. See Support Tip HT508158 for details.
For more information, including the transceivers and cables that each adapter supports, see the list of Lenovo Press Product Guides in the Networking adapters category:
https://lenovopress.com/servers/options/ethernet
Fibre Channel host bus adapters
The following table lists the Fibre Channel HBAs supported by SR850 server.
Part number |
Feature code |
Description | Slots supported |
Maximum supported |
---|---|---|---|---|
32 Gb Fibre Channel HBAs | ||||
4XC7A08250 | B5SX | ThinkSystem Emulex LPe35000 32Gb 1-port PCIe Fibre Channel Adapter | 1-5, 8, 9, 11 | 8 |
4XC7A08251 | B5SY | ThinkSystem Emulex LPe35002 32Gb 2-port PCIe Fibre Channel Adapter | 1-5, 8, 9, 11 | 8 |
7ZT7A00516 | AUNS | ThinkSystem QLogic QLE2740 PCIe 32Gb 1-Port SFP+ Fibre Channel Adapter | 1-5, 8, 9, 11 | 8 |
7ZT7A00518 | AUNU | ThinkSystem QLogic QLE2742 PCIe 32Gb 2-Port SFP+ Fibre Channel Adapter | 1-5, 8, 9, 11 | 8 |
7ZT7A00519 | AUNV | ThinkSystem Emulex LPe32002-M2-L PCIe 32Gb 2-Port SFP+ Fibre Channel Adapter | 1-5, 8, 9, 11 | 8 |
7ZT7A00517 | AUNT | ThinkSystem Emulex LPe32000-M2-L PCIe 32Gb 1-Port SFP+ Fibre Channel Adapter | 1-5, 8, 9, 11 | 8 |
16 Gb Fibre Channel HBAs | ||||
01CV750 | ATZB | QLogic 16Gb Enhanced Gen5 FC Single-port HBA | 1-5, 8, 9, 11 | 8 |
01CV760 | ATZC | QLogic 16Gb Enhanced Gen5 FC Dual-port HBA | 1-5, 8, 9, 11 | 8 |
01CV830 | ATZU | Emulex 16Gb Gen6 FC Single-port HBA | 1-5, 8, 9, 11 | 8 |
01CV840 | ATZV | Emulex 16Gb Gen6 FC Dual-port HBA | 1-5, 8, 9, 11 | 8 |
For more information, see the list of Lenovo Press Product Guides in the Host bus adapters category:
https://lenovopress.com/servers/options/hba
SAS adapters for external storage
The following table lists SAS HBAs and RAID adapters supported by SR850 server for use with external storage.
Part number |
Feature code |
Description | Slots supported |
Maximum supported |
---|---|---|---|---|
SAS HBAs | ||||
7Y37A01090 | AUNR | ThinkSystem 430-8e SAS/SATA 12Gb HBA | 1-5, 8, 9, 11 | 8 |
7Y37A01091 | AUNN | ThinkSystem 430-16e SAS/SATA 12Gb HBA | 1-5, 8, 9, 11 | 8 |
External RAID adapters | ||||
7Y37A01087 | AUNQ | ThinkSystem RAID 930-8e 4GB Flash PCIe 12Gb Adapter | 1-5, 8, 9, 11 | 4 |
For more information, see the list of Lenovo Press Product Guides in the Host bus adapters and RAID adapters categories:
https://lenovopress.com/servers/options/hba
https://lenovopress.com/servers/options/raid
The following table compares the specifications of the external SAS HBAs and RAID adapters.
Feature | 430-8e | 430-16e | 930-8e |
---|---|---|---|
Adapter type | HBA | HBA | External RAID |
Part number | 7Y37A01090 | 7Y37A01091 | 7Y37A01087 |
Controller chip | LSI SAS3408 | LSI SAS3416 | LSI SAS3516 |
Broadcom equivalent | HBA 9400-8e | HBA 9400-16e | MegaRAID 9480-8e |
Host interface | PCIe 3.0x8 | PCIe 3.0x8 | PCIe 3.0x8 |
Port interface | 12 Gb SAS | 12 Gb SAS | 12 Gb SAS |
Number of ports | 8 | 16 | 8 |
Port connectors | 2x Mini-SAS HD SFF8644 | 4x Mini-SAS HD SFF8644 | 2x Mini-SAS HD SFF8644 |
Drive interface | SAS/SATA | SAS/SATA | SAS,SATA |
Drive type | HDD/SSD/SED* | HDD/SSD/SED* | HDD,SED,SSD |
Hot-swap drives | Yes | Yes | Yes |
Maximum devices | 512 (planned: 1024) | 512 (planned: 1024) | 64 (planned: 216) |
RAID levels | None | None | 0/1/10/5/50/6/60 |
JBOD mode | Yes | Yes | Yes |
Cache | None | None | 4GB (Standard) |
CacheVault cache protection | None | None | Yes (Flash) |
Performance Accelerator (FastPath) | No | No | Yes |
SSD Caching (CacheCade Pro 2.0) | No | No | No |
SED support* | Yes | Yes | Yes |
* SAS HBAs support SEDs (self-encrypting drives) by using software on the server and simply passing SED commands through the HBA to the drives. SED support by RAID controllers is provided using the built-in MegaRAID SafeStore functionality of the adapter.
Flash storage adapters
The server supports the PCIe Flash Storage adapters listed in the following table.
Part number |
Feature code |
Description | Slots supported |
Maximum supported |
---|---|---|---|---|
Entry NVMe PCIe Adapters - Optimized for read-intensive workloads with an endurance of less than 3 DWPD. | ||||
7SD7A05776 | B11Z | ThinkSystem HHHL Intel P4500 4.0TB Entry NVMe PCIe 3.0 x4 Flash Adapter | 1-5, 8, 9, 11 | 8 |
7SD7A05775 | B120 | ThinkSystem HHHL Intel P4500 8.0TB Entry NVMe PCIe3.0 x4 Flash Adapter | 1-5, 8, 9, 11 | 8 |
Mainstream NVMe PCIe Adapters - Optimized for mixed-intensive application workloads with an endurance of 3-5 DWPD. | ||||
4XB7A14075 | B8JH | ThinkSystem HHHL PM1735 1.6TB Mainstream NVMe PCIe4.0 x4 Flash Adapter | 1-5, 8, 9, 11 | 8 |
4XB7A14076 | B8HW | ThinkSystem HHHL PM1735 3.2TB Mainstream NVMe PCIe4.0 x4 Flash Adapter | 1-5, 8, 9, 11 | 8 |
4XB7A14077 | B96M | ThinkSystem HHHL PM1735 6.4TB Mainstream NVMe PCIe4.0 x4 Flash Adapter | 1-5, 8, 9, 11 | 8 |
4XB7A38234 | BCGJ | ThinkSystem HHHL Kioxia CM5-V 1.6TB Mainstream NVMe PCIe3.0 x4 Flash Adapter | 1-5, 8, 9, 11 | 8 |
4XB7A38237 | BCGK | ThinkSystem HHHL Kioxia CM5-V 3.2TB Mainstream NVMe PCIe3.0 x4 Flash Adapter | 1-5, 8, 9, 11 | 8 |
4XB7A38240 | BCGL | ThinkSystem HHHL Kioxia CM5-V 6.4TB Mainstream NVMe PCIe3.0 x4 Flash Adapter | 1-5, 8, 9, 11 | 8 |
4XB7A08520 | B32L | ThinkSystem HHHL KCM51V 1.6TB Mainstream NVMe PCIe 3.0 x4 Flash Adapter | 1-5, 8, 9, 11 | 8 |
4XB7A08521 | B32M | ThinkSystem HHHL KCM51V 3.2TB Mainstream NVMe PCIe 3.0 x4 Flash Adapter | 1-5, 8, 9, 11 | 8 |
4XB7A08522 | B32N | ThinkSystem HHHL KCM51V 6.4TB Mainstream NVMe PCIe 3.0 x4 Flash Adapter | 1-5, 8, 9, 11 | 8 |
7SD7A05769 | B11X | ThinkSystem HHHL Intel P4600 2.0TB Mainstream NVMe PCIe3.0 x4 Flash Adapter | 1-5, 8, 9, 11 | 8 |
7SD7A05768 | B11Y | ThinkSystem HHHL Intel P4600 4.0TB Mainstream NVMe PCIe3.0 x4 Flash Adapter | 1-5, 8, 9, 11 | 8 |
7N47A00097 | AUUP | ThinkSystem HHHL PX04PMC 1.92TB Mainstream NVMe PCIe 3.0 x4 Flash Adapter | 1-5, 8, 9, 11 | 8 |
7N47A00098 | AUVY | ThinkSystem HHHL PX04PMC 3.84TB Mainstream NVMe PCIe 3.0 x4 Flash Adapter | 1-5, 8, 9, 11 | 8 |
Performance NVMe PCIe Adapters - Optimized for write-intensive application workloads with an endurance of 10+ DWPD. | ||||
7XB7A05925 | AWG8 | ThinkSystem HHHL PX04PMC 1.6TB Performance NVMe PCIe 3.0 x4 Flash Adapter | 1-5, 8, 9, 11 | 8 |
XB7A05924 | AWG9 | ThinkSystem HHHL PX04PMC 3.2TB Performance NVMe PCIe 3.0 x4 Flash Adapter | 1-5, 8, 9, 11 | 8 |
For details about these adapters, see the Lenovo Press product guides in the Flash Adapters category:
https://lenovopress.com/servers/options/ssdadapter
GPU adapters
The SR850 does not support any graphics processing units (GPUs).
Cooling
The server has six 60 mm hot-swap fans and all six fans are standard in all models. The server offers N+1 redundancy, meaning that one fan can fail and the server still operates normally.
Either 16K RPM fans or 19K RPM fans are used in the server, depending on the components used in the server.
Part number | Feature code | Description |
---|---|---|
CTO only | B81D | SR850/SR860 60x38 16K Fan Unit |
4F17A60142 | B81C | SR850/SR860 60x38 19K Fan Unit |
The 16K fan is the default selection, however the 19K fan is automatically selected when one of the following processors with high thermal characteristics is selected:
- Intel Xeon Gold 6126T 12C 125W 2.6GHz Processor
- Intel Xeon Gold 6144 8C 150W 3.5GHz Processor
- Intel Xeon Gold 6146 12C 165W 3.2GHz Processor
- Intel Xeon Gold 6154 18C 200W 3.0GHz Processor
- Intel Xeon Platinum 8160T 24C 150W 2.1GHz Processor
- Intel Xeon Platinum 8168 24C 205W 2.7GHz Processor
- Intel Xeon Platinum 8180 28C 205W 2.5GHz Processor
- Intel Xeon Platinum 8180M 28C 205W 2.5GHz Processor
For existing customers with the original 16K fans wish to operate the server without restrictions, the 19K RPM fans can be installed as field upgrades using part number 4F17A60142. The part number contains 1 fan. A total of 6 fans will need to be ordered.
Power supplies
The server supports up to two redundant hot-swap power supplies.
Installing a second power supply requires either the Processor and Memory Expansion Tray (7B27A03953) or the power interposer (feature AUPZ).
The power interposer enables redundant power support when the Processor and Memory Expansion Tray is not installed. If you do not have the Processor and Memory Expansion Tray installed and want to install two power supplies, then the power interposer card must be installed.
Tip: Use Lenovo Capacity Planner to determine exactly what power your server needs:
https://datacentersupport.lenovo.com/us/en/products/solutions-and-software/software/lenovo-capacity-planner/solutions/ht504651
Part number | Feature code |
Description | Maximum supported |
110V AC | 220V AC | 240V DC China only† |
---|---|---|---|---|---|---|
None* | AUPZ | SR850 2S Power Paddle (power interposer) | 1** | Yes | Yes | Yes |
7N67A00883 | AUPR | 750W Platinum (230V/115V) Power Supply | 2 | Yes | Yes | Yes |
7N67A00885 | AUPS | 1100W Platinum (230V/115V) Power Supply | 2 | Yes | Yes | Yes |
7N67A00886 | AUPT | 1600W Platinum (230V) Power Supply | 2 | No | Yes | Yes |
* Configure-to-order only
** Only needed if two power supplies are installed but the Processor and Memory Expansion Tray is not installed
† Support for 240 DC is planned
750W and 1100W power supplies are auto-sensing and support both 110V AC (100-127V 50/60 Hz) and 220V AC (200-240V 50/60 Hz) power. The 1600 W power supply only supports 220V AC power.
For China customers, all three power supplies are 240V DC ready; support is planned for a future date.
Note: At 110 V, the 1100W power supply generates 1050W of power.
Power supply options do not include a line cord.
For server configurations, the inclusion of a power cord is model dependent. Configure-to-order models can be configured without a power cord if desired.
Power cords
Line cords and rack power cables with C13 connectors can be ordered as listed in the following table.
110V customers: If you plan to use the 1100W power supply with a 110V power source, select a power cable that is rated above 10A. Power cables that are rated at 10A or below are not supported with 110V power.
Part number | Feature code | Description |
---|---|---|
Rack cables - C13 to C14 | ||
SL67B08593 | BPHZ | 0.5m, 10A/100-250V, C13 to C14 Jumper Cord |
00Y3043 | A4VP | 1.0m, 10A/100-250V, C13 to C14 Jumper Cord |
4L67A08367 | B0N5 | 1.0m, 13A/100-250V, C13 to C14 Jumper Cord |
39Y7937 | 6201 | 1.5m, 10A/100-250V, C13 to C14 Jumper Cord |
4L67A08368 | B0N6 | 1.5m, 13A/100-250V, C13 to C14 Jumper Cord |
4L67A08365 | B0N4 | 2.0m, 10A/100-250V, C13 to IEC 320-C14 Rack Power Cable |
4L67A08369 | 6570 | 2.0m, 13A/100-250V, C13 to C14 Jumper Cord |
4L67A08366 | 6311 | 2.8m, 10A/100-250V, C13 to C14 Jumper Cord |
4L67A08370 | 6400 | 2.8m, 13A/100-250V, C13 to C14 Jumper Cord |
39Y7932 | 6263 | 4.3m, 10A/100-250V, C13 to IEC 320-C14 Rack Power Cable |
4L67A08371 | 6583 | 4.3m, 13A/100-250V, C13 to C14 Rack Power Cable |
Rack cables - C13 to C14 (Y-cable) | ||
00Y3046 | A4VQ | 1.345m, 2X C13 to C14 Jumper Cord, Rack Power Cable |
00Y3047 | A4VR | 2.054m, 2X C13 to C14 Jumper Cord, Rack Power Cable |
Rack cables - C13 to C20 | ||
39Y7938 | 6204 | 2.8m, 10A/100-250V, C13 to IEC 320-C20 Rack Power Cable |
Rack cables - C13 to C20 (Y-cable) | ||
47C2491 | A3SW | 1.2m, 16A/100-250V, 2 Short C13s to Short C20 Rack Power Cable |
47C2492 | A3SX | 2.5m, 16A/100-250V, 2 Long C13s to Short C20 Rack Power Cable |
47C2493 | A3SY | 2.8m, 16A/100-250V, 2 Short C13s to Long C20 Rack Power Cable |
47C2494 | A3SZ | 4.1m, 16A/100-250V, 2 Long C13s to Long C20 Rack Power Cable |
Line cords | ||
39Y7930 | 6222 | 2.8m, 10A/250V, C13 to IRAM 2073 (Argentina) Line Cord |
81Y2384 | 6492 | 4.3m 10A/220V, C13 to IRAM 2073 (Argentina) Line Cord |
39Y7924 | 6211 | 2.8m, 10A/250V, C13 to AS/NZ 3112 (Australia/NZ) Line Cord |
81Y2383 | 6574 | 4.3m, 10A/230V, C13 to AS/NZS 3112 (Aus/NZ) Line Cord |
69Y1988 | 6532 | 2.8m, 10A/250V, C13 to NBR 14136 (Brazil) Line Cord |
81Y2387 | 6404 | 4.3m, 10A/250V, C13 - 2P+Gnd (Brazil) Line Cord |
39Y7928 | 6210 | 2.8m, 220-240V, C13 to GB 2099.1 (China) Line Cord |
81Y2378 | 6580 | 4.3m, 10A/220V, C13 to GB 2099.1 (China) Line Cord |
39Y7918 | 6213 | 2.8m, 10A/250V, C13 to DK2-5a (Denmark) Line Cord |
81Y2382 | 6575 | 4.3m, 10A/230V, C13 to DK2-5a (Denmark) Line Cord |
39Y7917 | 6212 | 2.8m, 10A/230V, C13 to CEE7-VII (Europe) Line Cord |
81Y2376 | 6572 | 4.3m, 10A/230V, C13 to CEE7-VII (Europe) Line Cord |
39Y7927 | 6269 | 2.8m, 10A/250V, C13(2P+Gnd) (India) Line Cord |
81Y2386 | 6567 | 4.3m, 10A/240V, C13 to IS 6538 (India) Line Cord |
39Y7920 | 6218 | 2.8m, 10A/250V, C13 to SI 32 (Israel) Line Cord |
81Y2381 | 6579 | 4.3m, 10A/230V, C13 to SI 32 (Israel) Line Cord |
39Y7921 | 6217 | 2.8m, 220-240V, C13 to CEI 23-16 (Italy/Chile) Line Cord |
81Y2380 | 6493 | 4.3m, 10A/230V, C13 to CEI 23-16 (Italy/Chile) Line Cord |
46M2593 | A1RE | 2.8m, 12A/125V, C13 to JIS C-8303 (Japan) Line Cord |
4L67A08362 | 6495 | 4.3m, 12A/200V, C13 to JIS C-8303 (Japan) Line Cord |
39Y7926 | 6335 | 4.3m, 12A/100V, C13 to JIS C-8303 (Japan) Line Cord |
39Y7922 | 6214 | 2.8m, 10A/250V, C13 to SABS 164 (S Africa) Line Cord |
81Y2379 | 6576 | 4.3m, 10A/230V, C13 to SABS 164 (South Africa) Line Cord |
39Y7925 | 6219 | 2.8m, 220-240V, C13 to KETI (S Korea) Line Cord |
81Y2385 | 6494 | 4.3m, 12A/220V, C13 to KSC 8305 (S. Korea) Line Cord |
39Y7919 | 6216 | 2.8m, 10A/250V, C13 to SEV 1011-S24507 (Swiss) Line Cord |
81Y2390 | 6578 | 4.3m, 10A/230V, C13 to SEV 1011-S24507 (Sws) Line Cord |
23R7158 | 6386 | 2.8m, 10A/125V, C13 to CNS 10917-3 (Taiwan) Line Cord |
81Y2375 | 6317 | 2.8m, 10A/240V, C13 to CNS 10917-3 (Taiwan) Line Cord |
81Y2374 | 6402 | 2.8m, 13A/125V, C13 to CNS 60799 (Taiwan) Line Cord |
4L67A08363 | AX8B | 4.3m, 10A 125V, C13 to CNS 10917 (Taiwan) Line Cord |
81Y2389 | 6531 | 4.3m, 10A/250V, C13 to 76 CNS 10917-3 (Taiwan) Line Cord |
81Y2388 | 6530 | 4.3m, 13A/125V, C13 to CNS 10917 (Taiwan) Line Cord |
39Y7923 | 6215 | 2.8m, 10A/250V, C13 to BS 1363/A (UK) Line Cord |
81Y2377 | 6577 | 4.3m, 10A/230V, C13 to BS 1363/A (UK) Line Cord |
90Y3016 | 6313 | 2.8m, 10A/120V, C13 to NEMA 5-15P (US) Line Cord |
46M2592 | A1RF | 2.8m, 10A/250V, C13 to NEMA 6-15P Line Cord |
00WH545 | 6401 | 2.8m, 13A/120V, C13 to NEMA 5-15P (US) Line Cord |
4L67A08359 | 6370 | 4.3m, 10A/125V, C13 to NEMA 5-15P (US) Line Cord |
4L67A08361 | 6373 | 4.3m, 10A/250V, C13 to NEMA 6-15P (US) Line Cord |
4L67A08360 | AX8A | 4.3m, 13A/120V, C13 to NEMA 5-15P (US) Line Cord |
Integrated virtualization
The server supports booting from an operating system or hypervisor installed on an M.2 solid-state drive. See the M.2 drives section for details and the list of available options.
You can download supported VMware vSphere hypervisor images from the following web page and load it on the M.2 drive using the instructions provided:
https://vmware.lenovo.com/content/custom_iso/
Systems management
The server contains an integrated service processor, XClarity Controller (XCC), which provides advanced control, monitoring, and alerting functions. The XCC is based on the Pilot4 XE401 baseboard management controller (BMC) using a dual-core ARM Cortex A9 service processor.
Local management
The SR850 offers a front operator panel with key LED status indicators, as shown in the following figure.
Figure 14. Front operator panel
As an alternative to the front operator panel, (certain models or configure-to-order; not available as a field upgrade), the server supports a pull-out LCD display panel. The LCD display panel allows quick access to system status, firmware, network, and health information. The following figure shows the front operator panel with LCD display.
Figure 15. Front operator panel with LCD display
The LCD display and the function buttons give you access to the following information:
- Error messages
- System VPD: machine type & mode, serial number, UUID string
- System firmware levels: UEFI and XCC firmware
- XCC network information: hostname, MAC address, IP address, DNS addresses
- Environmental data: Ambient temperature, CPU temperature, AC input voltage, estimated power consumption
- System reset action
The front operator panel with LCD display can be ordered as listed in the following table.
Part number | Feature code | Description |
---|---|---|
None* | AUMW | Front operator panel with LCD display |
* Only available configure-to-order or with predefined models
The server offers light path diagnostics. If an environmental condition exceeds a threshold or if a system component fails, the XCC lights LEDs inside the server to help you diagnose the problem and find the failing part. The SR850 has fault LEDs next to the following components:
- Each processor
- Each memory DIMM
- Each drive bay
- Each system fan
- Each power supply
The front of the server also houses an information pull-out tab (also known as the network access tag). See Figure 2 for the location. A label on the tab shows the network information (MAC address and other data) to remotely access XClarity Controller.
System status with XClarity Mobile
The XClarity Mobile app includes a tethering function where you can connect your Android or iOS device to the server via USB to see the status of the server.
The steps to connect the mobile device are as follows:
- Enable USB Management on the server, by holding down the ID button for 3 seconds (or pressing the dedicated USB management button if one is present)
- Connect the mobile device via a USB cable to the server's USB port with the management symbol
- In iOS or Android settings, enable Personal Hotspot or USB Tethering
- Launch the Lenovo XClarity Mobile app
Once connected you can see the following information:
- Server status including error logs (read only, no login required)
- Server management functions (XClarity login credentials required)
Remote management
The server offers a dedicated RJ45 port at the rear of the server for remote management via the XClarity Controller management processor. The port supports 10/100/1000 Mbps speeds.
Remote server management is provided through industry-standard interfaces:
- Intelligent Platform Management Interface (IPMI) Version 2.0
- Simple Network Management Protocol (SNMP) Version 3 (no SET commands; no SMNP v1)
- Common Information Model (CIM-XML)
- Representational State Transfer (REST) support
- Redfish support (DMTF compliant)
- Web browser - HTML 5-based browser interface (Java and ActiveX not required) using a responsive design (content optimized for the device being used - laptop, tablet, phone) with NLS support
IPMI via the Ethernet port (IPMI over LAN) is supported, however it is disabled by default. For CTO orders you can specify whether you want to the feature enabled or disabled in the factory, using the feature codes listed in the following table.
Part number | Feature code | Description |
---|---|---|
CTO only | B7XZ | Disable IPMI-over-LAN (default) |
CTO only | B7Y0 | Enable IPMI-over-LAN |
A virtual presence (remote control) capability also comes standard in the server for remote server management. Virtual media (remote drive images) support is optional via a software license upgrade.
The remote control functions include the following:
- Remotely viewing video with graphics resolutions up to 1600x1200 at 75 Hz with up to 23 bits per pixel, regardless of the system state
- Remotely accessing the server using the keyboard and mouse from a remote client
- Capturing blue-screen errors
- International keyboard mapping support
- LDAP-based authentication
- With the XCC Enterprise license upgrade, mapping ISO and diskette IMG image files as virtual drives that are available for use by the server
The Enterprise license upgrade, shown in the following table, enables the following features:
- Boot Capture
- Remote mounting of ISO and IMG files
- Virtual console collaboration - Ability for up to 6 remote users to be log into the remote session simultaneously
- Power capping
- License for XClarity Energy Manager
Part number | Feature code | Description |
---|---|---|
4L47A09133 | AVUU | ThinkSystem XClarity Controller Advanced to Enterprise Upgrade |
Lenovo XClarity Administrator
Lenovo XClarity Administrator is a centralized resource management solution designed to reduce complexity, speed response, and enhance the availability of Lenovo systems and solutions. It provides agent-free hardware management for ThinkSystem servers, in addition to ThinkServer, System x, and Flex System servers. The administration dashboard is based on HTML 5 and allows fast location of resources so tasks can be run quickly.
Because Lenovo XClarity Administrator does not require any agent software to be installed on the managed endpoints, there are no CPU cycles spent on agent execution, and no memory is used, which means that up to 1GB of RAM and 1 - 2% CPU usage is saved, compared to a typical managed system where an agent is required.
Lenovo XClarity Administrator is an optional software component for the SR850. The software can be downloaded and used at no charge to discover and monitor the SR850 and to manage firmware upgrades.
If software support is required for Lenovo XClarity Administrator, or premium features such as configuration management and operating system deployment are required, Lenovo XClarity Pro software subscription should be ordered. Lenovo XClarity Pro is licensed on a per managed system basis, that is, each managed Lenovo system requires a license.
The following table lists the Lenovo XClarity software license options.
Part number | Feature code | Description |
---|---|---|
00MT201 | 1339 | Lenovo XClarity Pro, per Managed Endpoint w/1 Yr SW S&S |
00MT202 | 1340 | Lenovo XClarity Pro, per Managed Endpoint w/3 Yr SW S&S |
00MT203 | 1341 | Lenovo XClarity Pro, per Managed Endpoint w/5 Yr SW S&S |
7S0X000HWW | SAYV | Lenovo XClarity Pro, per Managed Endpoint w/6 Yr SW S&S |
7S0X000JWW | SAYW | Lenovo XClarity Pro, per Managed Endpoint w/7 Yr SW S&S |
Lenovo XClarity Administrator offers the following standard features that are available at no charge:
- Auto-discovery and monitoring of Lenovo systems
- Firmware updates and compliance enforcement
- External alerts and notifications via SNMP traps, syslog remote logging, and e-mail
- Secure connections to managed endpoints
- NIST 800-131A or FIPS 140-2 compliant cryptographic standards between the management solution and managed endpoints
- Integration into existing higher-level management systems such as cloud automation and orchestration tools through REST APIs, providing extensive external visibility and control over hardware resources
- An intuitive, easy-to-use GUI
- Scripting with Windows PowerShell, providing command-line visibility and control over hardware resources
Lenovo XClarity Administrator offers the following premium features that require an optional Pro license:
- Pattern-based configuration management that allows to define configurations once and apply repeatedly without errors when deploying new servers or redeploying existing servers without disrupting the fabric
- Bare-metal deployment of operating systems and hypervisors to streamline infrastructure provisioning
For more information, refer to the Lenovo XClarity Administrator Product Guide:
http://lenovopress.com/tips1200
Lenovo XClarity Integrators
Lenovo also offers software plug-in modules, Lenovo XClarity Integrators, to manage physical infrastructure from leading external virtualization management software tools including those from Microsoft and VMware.
These integrators are offered at no charge, however if software support is required, a Lenovo XClarity Pro software subscription license should be ordered.
Lenovo XClarity Integrators offer the following additional features:
- Ability to discover, manage, and monitor Lenovo server hardware from VMware vCenter or Microsoft System Center
- Deployment of firmware updates and configuration patterns to Lenovo x86 rack servers and Flex System from the virtualization management tool
- Non-disruptive server maintenance in clustered environments that reduces workload downtime by dynamically migrating workloads from affected hosts during rolling server updates or reboots
- Greater service level uptime and assurance in clustered environments during unplanned hardware events by dynamically triggering workload migration from impacted hosts when impending hardware failures are predicted
For more information about all the available Lenovo XClarity Integrators, see the Lenovo XClarity Administrator Product Guide: https://lenovopress.com/tips1200-lenovo-xclarity-administrator
Lenovo XClarity Provisioning Manager
Lenovo XClarity Provisioning Manager (LXPM) is a UEFI-based application embedded in ThinkSystem servers and accessible via the F1 key during system boot.
LXPM provides the following functions:
- Graphical UEFI Setup
- System inventory information and VPD update
- System firmware updates (UEFI and XCC)
- RAID setup wizard
- OS installation wizard (including unattended OS installation)
- Diagnostics functions
Lenovo XClarity Essentials
Lenovo offers the following XClarity Essentials software tools that can help you set up, use, and maintain the server at no additional cost:
- Lenovo Essentials OneCLI
OneCLI is a collection of server management tools that uses a command line interface program to manage firmware, hardware, and operating systems. It provides functions to collect full system health information (including health status), configure system settings, and update system firmware and drivers.
- Lenovo Essentials UpdateXpress
The UpdateXpress tool is a standalone GUI application for firmware and device driver updates that enables you to maintain your server firmware and device drivers up-to-date and help you avoid unnecessary server outages. The tool acquires and deploys individual updates and UpdateXpress System Packs (UXSPs) which are integration-tested bundles.
- Lenovo Essentials Bootable Media Creator
The Bootable Media Creator (BOMC) tool is used to create bootable media for offline firmware update.
For more information and downloads, visit the Lenovo XClarity Essentials web page:
http://support.lenovo.com/us/en/documents/LNVO-center
Lenovo XClarity Energy Manager
Lenovo XClarity Energy Manager (LXEM) is a power and temperature management solution for data centers. It is an agent-free, web-based console that enables you to monitor and manage power consumption and temperature in your data center through the management console. It enables server density and data center capacity to be increased through the use of power capping.
LXEM is a licensed product. A single-node LXEM license is included with the XClarity Controller Enterprise upgrade as described in the Remote Management section. If your server does not have the XCC Enterprise upgrade, Energy Manager licenses can be ordered as shown in the following table.
Part number | Description |
---|---|
4L40E51621 | Lenovo XClarity Energy Manager Node License (1 license needed per server) |
For more information about XClarity Energy Manager, see the following resources:
- Lenovo Support page:
https://datacentersupport.lenovo.com/us/en/solutions/lnvo-lxem - User Guide for XClarity Energy Manager:
https://pubs.lenovo.com/lxem/
Security
The server offers the following security features:
- Administrator and power-on password
- Trusted Platform Module (TPM) supporting both TPM 1.2 and TPM 2.0
- Optional Trusted Cryptographic Module (TCM) or Nationz TPM 2.0, available only in China
- Lockable top cover to help prevent access to internal components
- Optional lockable front security bezel
- Self-encrypting drives with support for IBM Security Key Lifecycle Manager
The TCM and Nationz TPM modules, available only for China customers, are installed in a dedicated socket on the system board, as shown in Figure 4.
The optional lockable front bezel is shown in the following figure and includes a key that enables you to secure the bezel over the drives and system controls thereby reducing the chance of unauthorized or accidental access to the server.
Figure 16. Lockable front security bezel
The dimensions of the security bezel are:
- Width: 437 mm (17.2 in.)
- Height: 87 mm (3.4 in.)
- Width: 23 mm (0.9 in.)
The following table lists the security options for the server.
Part number | Feature code | Description |
---|---|---|
None* | AVKE | ThinkSystem Trusted Cryptographic Module (China customers only) |
None* | B22N | ThinkSystem Nationz Trusted Platform Module v2.0 (China customers only) |
7Z17A02580 | AURX | ThinkSystem 2U Security Bezel |
* Not available as a field upgrade. The component is CTO on pre-configured models only.
For SED drives and IBM Security Key Lifecycle Manager support see the SED encryption key management with ISKLM section.
Rack installation
The following table lists the rack installation options that are available for the server.
The Front VGA Connector Upgrade Kit allows you to upgrade your server by adding a VGA video port to the front of the server (if the server does not already come with a front VGA port). When the front VGA is in use, the rear VGA port is automatically disabled.
Option | Feature Code | Description |
---|---|---|
Optional front VGA port | ||
7X97A03954 | AUPX | ThinkSystem SR850 Front VGA Connector Upgrade Kit |
Rail slides | ||
7M27A05700 | AXCH | ThinkSystem Toolless Slide Rail Kit with 2U CMA |
7M27A05702 | AXCA | ThinkSystem Toolless Slide Rail |
4M17A07274 | AXFN | ThinkSystem Tooled Slide Rail |
4M17A07273 | AXFM | ThinkSystem Toolless Friction Rail |
Cable Management Arms | ||
4M17A07275 | AXFU | ThinkSystem 2U CMA Upgrade Kit for Tooled Slide Rail |
7M27A05698 | None* | ThinkSystem 2U CMA Upgrade Kit for Toolless Slide Rail |
* This kit is for field upgrades only; for CTO use the rail kit with CMA, feature AXCH
The following table summarizes the rail kit features and specifications.
Feature | ThinkSystem Toolless Slide Rail | ThinkSystem Tooled Slide Rail | ThinkSystem Toolless Friction Rail |
---|---|---|---|
Part number | 7M27A05702 (no CMA) 7M27A05700 (with CMA) |
4M17A07274 | 4M17A07273 |
Rail type | Full-out slide (ball bearing) | Full-out slide (ball bearing) | Half-out slide (friction) |
Toolless installation | Yes | No | Yes |
Cable Management Arm (CMA) support |
Yes (7M27A05700 only) |
Optional (4M17A07275) |
No |
In-rack server maintenance | Yes | Yes | No |
1U PDU support | Yes | Yes | Yes |
0U PDU support | Limited* | Limited* | Limited** |
Rack type | Lenovo and IBM 4-post, IEC standard-compliant |
Lenovo and IBM 4-post, IEC standard-compliant |
Lenovo and IBM 4-post, IEC standard-compliant |
Mounting holes | Square or round | Square, round, or threaded | Square or round |
Mounting flange thickness | 2 mm - 3.3 mm (0.08 - 0.13 in.) |
2 mm - 3.3 mm (0.08 - 0.13 in.) |
2 mm - 3.3 mm (0.08 - 0.13 in.) |
Distance between front and rear mounting flanges |
610 mm - 864 mm (24 - 34 in.) |
610 mm - 864 mm (24 - 34 in.) |
610 mm - 864 mm (24 - 34 in.) |
Rail length*** | 730 mm (28.74 in.) | 837 mm (32.9 in.) | 728 mm (28.7 in.) |
* For 0U PDU support, the rack must be at least 1100 mm (43.31 in.) deep without a CMA, or at least 1200 mm (47.24 in.) deep if a CMA is used.
** For 0U PDU support with the friction rail kit, the rack must be at least 1000 mm (39.37 in.) deep.
*** Measured when mounted on the rack, from the front surface of the front mounting flange to the rear most point of the rail.
Operating system support
The server supports the following operating systems:
- Microsoft Windows Server 2012 R2
- Microsoft Windows Server 2016
- Microsoft Windows Server 2019
- Microsoft Windows Server 2022
- Microsoft Windows Server, version 1709
- Microsoft Windows Server, version 1803
- Red Hat Enterprise Linux 6.9 x64
- Red Hat Enterprise Linux 6.10 x64
- Red Hat Enterprise Linux 7.3
- Red Hat Enterprise Linux 7.4
- Red Hat Enterprise Linux 7.5
- Red Hat Enterprise Linux 7.6
- Red Hat Enterprise Linux 7.7
- Red Hat Enterprise Linux 7.8
- Red Hat Enterprise Linux 7.9
- Red Hat Enterprise Linux 8.0
- Red Hat Enterprise Linux 8.1
- Red Hat Enterprise Linux 8.2
- Red Hat Enterprise Linux 8.3
- Red Hat Enterprise Linux 8.4
- Red Hat Enterprise Linux 8.5
- Red Hat Enterprise Linux 8.6
- Red Hat Enterprise Linux 8.7
- Red Hat Enterprise Linux 8.8
- Red Hat Enterprise Linux 9.0
- Red Hat Enterprise Linux 9.1
- Red Hat Enterprise Linux 9.2
- SUSE Linux Enterprise Server 11 Xen x64 SP4
- SUSE Linux Enterprise Server 11 x64 SP4
- SUSE Linux Enterprise Server 12 SP2
- SUSE Linux Enterprise Server 12 SP3
- SUSE Linux Enterprise Server 12 SP4
- SUSE Linux Enterprise Server 12 SP5
- SUSE Linux Enterprise Server 12 Xen SP2
- SUSE Linux Enterprise Server 12 Xen SP3
- SUSE Linux Enterprise Server 12 Xen SP4
- SUSE Linux Enterprise Server 12 Xen SP5
- SUSE Linux Enterprise Server 15
- SUSE Linux Enterprise Server 15 SP1
- SUSE Linux Enterprise Server 15 SP2
- SUSE Linux Enterprise Server 15 SP3
- SUSE Linux Enterprise Server 15 SP4
- SUSE Linux Enterprise Server 15 SP5
- SUSE Linux Enterprise Server 15 Xen
- SUSE Linux Enterprise Server 15 Xen SP1
- SUSE Linux Enterprise Server 15 Xen SP2
- SUSE Linux Enterprise Server 15 Xen SP3
- SUSE Linux Enterprise Server 15 Xen SP4
- SUSE Linux Enterprise Server 15 Xen SP5
- Ubuntu 22.04 LTS 64-bit
- VMware ESXi 6.0 U3
- VMware ESXi 6.5
- VMware ESXi 6.5 U1
- VMware ESXi 6.5 U2
- VMware ESXi 6.5 U3
- VMware ESXi 6.7
- VMware ESXi 6.7 U1
- VMware ESXi 6.7 U2
- VMware ESXi 6.7 U3
- VMware ESXi 7.0
- VMware ESXi 7.0 U1
- VMware ESXi 7.0 U2
- VMware ESXi 7.0 U3
- VMware ESXi 8.0
- VMware ESXi 8.0 U1
- VMware ESXi 8.0 U2
For a complete list of supported, certified and tested operating systems, plus additional details and links to relevant web sites, see the Operating System Interoperability Guide: https://lenovopress.com/osig#servers=sr850-7x18-7x19
For configure-to-order configurations, the server can be preloaded with VMware ESXi installed on M.2 cards. Ordering information is listed in the following table.
Part number | Feature code | Description |
---|---|---|
CTO only | AXFS | VMware ESXi 6.0 U3 (factory installed) |
CTO only | AXFT | VMware ESXi 6.5 U1 (factory installed) |
CTO only | B3VW | VMware ESXi 6.5 U2 (Factory Installed) |
CTO only | B6U0 | VMware ESXi 6.5 U3 (factory installed) |
CTO only | B3VX | VMware ESXi 6.7 (Factory Installed) |
CTO only | B4XA | VMware ESXi 6.7 U1 (Factory Installed) |
CTO only | B6U1 | VMware ESXi 6.7 U2 (factory installed) |
CTO only | B88T | VMware ESXi 6.7 U3 (factory installed) |
CTO only | BBZG | VMware ESXi 7.0 (Factory Installed) |
CTO only | BE5E | VMware ESXi 7.0 U1 (Factory Installed) |
Physical and electrical specifications
The SR850 has the following overall physical dimensions, excluding components that extend outside the standard chassis, such as EIA flanges, front security bezel (if any), and power supply handles:
- Width: 445 mm (17.5 inches)
- Height: 87 mm (3.4 inches)
- Depth: 765 mm (30.1 inches)
The following table lists the detailed dimensions. See the figure below for the definition of each dimension.
Dimension | Description |
---|---|
482 mm | Xa = Width, to the outsides of the front EIA flanges |
435 mm | Xb = Width, to the rack rail mating surfaces |
445 mm | Xc = Width, to the outer most chassis body feature |
87 mm | Ya = Height, from the bottom of chassis to the top of the chassis |
693 mm | Za = Depth, from the rack flange mating surface to the rearmost I/O port surface |
730 mm | Zb = Depth, from the rack flange mating surface to the rearmost feature of the chassis body |
728 mm | Zc = Depth, from the rack flange mating surface to the rearmost feature such as power supply handle |
35 mm | Zd = Depth, from the forwardmost feature on front of EIA flange to the rack flange mating surface |
47 mm | Ze = Depth, from the front of security bezel (if applicable) or forwardmost feature to the rack flange mating surface |
The shipping (cardboard packaging) dimensions of the SR850 are as follows:
- Width: 592 mm (23.3 inches)
- Height: 282 mm (11.1 inches)
- Depth: 992 mm (39.1 inches)
Weight:
- Minimum 18 kg (40 lb.), fully configured 27 kg (59.6 lb.)
Electrical specifications:
- Electrical - Input voltage
- 100 - 127 (nominal) V AC, 50 Hz or 60 Hz
- 200 - 240 (nominal) V AC, 50 Hz or 60 Hz
- 180 - 300 V DC (support is planned; China only)
- Power consumption:
- 100-127 V:
- 750W power supply: 8.4 kVA
- 1100W power supply: 12 kVA
- 200-240 V:
- 750W power supply: 4.1 kVA
- 1100W power supply: 6 kVA
- 1600W power supply: 8.7 kVA
- 100-127 V:
Operating environment
The ThinkSystem SR850 server complies with ASHRAE Class A2 specifications, and depending on the hardware configuration, also complies with ASHRAE Class A3 and Class A4 specifications. System performance may be impacted when operating temperature is outside ASHRAE A2 specification.
To comply with ASHRAE class A3 and class A4 specifications, the server models must meet the following hardware configuration requirements:
- Two power supplies installed
- NVMe drives not installed
- PCIe flash storage adapters not installed
CPU core speed may be reduced depending on the processor selected.
Cooling restrictions: Certain high-performance processors have additional cooling restrictions regarding ambient temperature and fan redundancy. See the Cooling section for details.
The server is supported in the following environment:
- Air temperature:
- Operating:
- ASHRAE Class A2: 10°C to 35°C (50°F to 95°F); the maximum ambient temperature decreases by 1°C for every 300 m (984 ft) increase in altitude above 900 m (2,953 ft).
- ASHRAE Class A3: 5°C to 40°C (41°F to 104°F); the maximum ambient temperature decreases by 1°C for every 175 m (574 ft) increase in altitude above 900 m (2,953 ft).
- ASHRAE Class A4: 5°C to 45°C (41°F to 113°F); the maximum ambient temperature decreases by 1°C for every 125 m (410 ft) increase in altitude above 900 m (2,953 ft).
- Server off: 5°C to 45°C (41°F to 113°F)
- Shipment/storage: -40°C to 60°C (-40°F to 140°F)
- Operating:
- Maximum altitude: 3,050 m (10,000 ft)
- Relative Humidity (non-condensing):
- Operating
- ASHRAE Class A2: 8% to 80%; maximum dew point: 21°C (70°F)
- ASHRAE Class A3: 8% to 85%; maximum dew point: 24°C (75°F)
- ASHRAE Class A4: 8% to 90%; maximum dew point: 24°C (75°F)
- Shipment/storage: 8% to 90%
- Operating
The server generates the following heat and noise:
- Heat/thermal output:
- Minimum configuration: 454 BTU/hr, 133 W
- Maximum configuration: 5118 BTU/hr, 1500 W
- Noise level (LWAm)
- Sound power, idling: 5.2 bels (minimum), 5.8 bels (typical), 6.4 bels (maximum)
- Sound power, operating: 5.8 bels (minimum), 6.8 bels (typical), 7.0 bels (maximum)
The server has the following vibration and shock limits:
- Vibration:
- Operating: 0.21 G rms at 5 Hz to 500 Hz for 15 minutes across 3 axes
- Non-operating: 1.04 G rms at 2 Hz to 200 Hz for 15 minutes across 6 surfaces
- Shock:
- Operating: 15 G for 3 milliseconds in each direction (positive and negative X, Y, and Z axes)
- Non-operating:
- 12 kg - 22 kg: 50 G for 152 in./sec velocity change across 6 surfaces
- 23 kg - 31 kg: 35 G for 152 in./sec velocity change across 6 surfaces
Warranty upgrades and post-warranty support
The SR850 has a 1-year or 3-year warranty based on the machine type of the system:
- 7X18: 1 year warranty
- 7X19: 3 year warranty
Our global network of regional support centers offers consistent, local-language support enabling you to vary response times and level of service to match the criticality of your support needs:
- Standard Next Business Day – Best choice for non-essential systems requiring simple maintenance.
- Premier Next Business Day – Best choice for essential systems requiring technical expertise from senior-level Lenovo engineers.
- Premier 24x7 4-Hour Response – Best choice for systems where maximum uptime is critical.
- Premier Enhanced Storage Support 24x7 4-Hour Response – Best choice for storage systems where maximum uptime is critical.
For more information, consult the brochure Lenovo Operational Support Services for Data Centers Services.
Services
Lenovo Data Center Services empower you at every stage of your IT lifecycle. From expert advisory and strategic planning to seamless deployment and ongoing support, we ensure your infrastructure is built for success. Our comprehensive services accelerate time to value, minimize downtime, and free your IT staff to focus on driving innovation and business growth.
Note: Some service options may not be available in all markets or regions. For more information, go to https://lenovolocator.com/. For information about Lenovo service upgrade offerings that are available in your region, contact your local Lenovo sales representative or business partner.
In this section:
- Lenovo Advisory Services
- Lenovo Plan & Design Services
- Lenovo Deployment, Migration, and Configuration Services
- Lenovo Support Services
- Lenovo Managed Services
- Lenovo Sustainability Services
Lenovo Advisory Services
Lenovo Advisory Services simplify the planning process, enabling customers to build future-proofed strategies in as little as six weeks. Consultants provide guidance on projects including VM migration, storage, backup and recovery, and cost management to accelerate time to value, improve cost efficiency, and build a flexibly scalable foundation.
- Assessment Services
An Assessment helps solve your IT challenges through an onsite, multi-day session with a Lenovo technology expert. We perform a tools-based assessment which provides a comprehensive and thorough review of a company's environment and technology systems. In addition to the technology based functional requirements, the consultant also discusses and records the non-functional business requirements, challenges, and constraints. Assessments help organizations like yours, no matter how large or small, get a better return on your IT investment and overcome challenges in the ever-changing technology landscape.
- Design Services
Professional Services consultants perform infrastructure design and implementation planning to support your strategy. The high-level architectures provided by the assessment service are turned into low level designs and wiring diagrams, which are reviewed and approved prior to implementation. The implementation plan will demonstrate an outcome-based proposal to provide business capabilities through infrastructure with a risk-mitigated project plan.
Lenovo Plan & Design Services
Unlock faster time to market with our tailored, strategic design workshops to align solution approaches with your business goals and technical requirements. Leverage our deep solution expertise and end-to-end delivery partnership to meet your goals efficiently and effectively.
Lenovo Deployment, Migration, and Configuration Services
Optimize your IT operations by shifting labor-intensive functions to Lenovo's skilled technicians for seamless on-site or remote deployment, configuration, and migration. Enjoy peace of mind, faster time to value, and comprehensive knowledge sharing with your IT staff, backed by our best-practice methodology.
- Deployment Services for Storage and ThinkAgile
A comprehensive range of remote and onsite options tailored specifically for your business needs to ensure your storage and ThinkAgile hardware are fully operational from the start.
- Hardware Installation Services
A full-range, comprehensive setup for your hardware, including unpacking, inspecting, and positioning components to ensure your equipment is operational and error-free for the most seamless and efficient installation experience, so you can quickly benefit from your investments.
- DM/DG File Migration Services
Take the burden of file migration from your IT’s shoulders. Our experts will align your requirements and business objectives to the migration plans while coordinating with your team to plan and safely execute the data migration to your storage platforms.
- DM/DG/DE Health Check Services
Our experts perform proactive checks of your Firmware and system health to ensure your machines are operating at peak and optimal efficiency to maximize up-time, avoid system failures, ensure the security of IT solutions and simplify maintenance.
- Factory Integrated Services
A suite of value-added offerings provided during the manufacturing phase of a server or storage system that reduces time to value. These services aim at improving your hardware deployment experience and enhance the quality of a standard configuration before it arrives at your facility.
Lenovo Support Services
In addition to response time options for hardware parts, repairs, and labor, Lenovo offers a wide array of additional support services to ensure your business is positioned for success and longevity. Our goal is to reduce your capital outlays, mitigate your IT risks, and accelerate your time to productivity.
- Premier Support for Data Centers
Your direct line to the solution that promises the best, most comprehensive level of support to help you fully unlock the potential of your data center.
- Premier Enhanced Storage Support (PESS)
Gain all the benefits of Premier Support for Data Centers, adding dedicated storage specialists and resources to elevate your storage support experience to the next level.
- Committed Service Repair (CSR)
Our commitment to ensuring the fastest, most seamless resolution times for mission-critical systems that require immediate attention to ensure minimal downtime and risk for your business. This service is only available for machines under the Premier 4-Hour Response SLA.
- Multivendor Support Services (MVS)
Your single point of accountability for resolution support across vast range of leading Server, Storage, and Networking OEMs, allowing you to manage all your supported infrastructure devices seamlessly from a single source.
- Keep Your Drive (KYD)
Protect sensitive data and maintain compliance with corporate retention and disposal policies to ensure your data is always under your control, regardless of the number of drives that are installed in your Lenovo server.
- Technical Account Manager (TAM)
Your single point of contact to expedite service requests, provide status updates, and furnish reports to track incidents over time, ensuring smooth operations and optimized performance as your business grows.
- Enterprise Software Support (ESS)
Gain comprehensive, single-source, and global support for a wide range of server operating systems and Microsoft server applications.
For more information, consult the brochure Lenovo Operational Support Services for Data Centers.
Lenovo Managed Services
Achieve peak efficiency, high security, and minimal disruption with Lenovo's always-on Managed Services. Our real-time monitoring, 24x7 incident response, and problem resolution ensure your infrastructure operates seamlessly. With quarterly health checks for ongoing optimization and innovation, Lenovo's remote active monitoring boosts end-user experience and productivity by keeping your data center's hardware performing at its best.
Lenovo Managed Services provides continuous 24x7 remote monitoring (plus 24x7 call center availability) and proactive management of your data center using state-of-the-art tools, systems, and practices by a team of highly skilled and experienced Lenovo services professionals.
Quarterly reviews check error logs, verify firmware & OS device driver levels, and software as needed. We’ll also maintain records of latest patches, critical updates, and firmware levels, to ensure you systems are providing business value through optimized performance.
Lenovo Sustainability Services
- Asset Recovery Services
Lenovo Asset Recovery Services (ARS) provides a secure, seamless solution for managing end-of-life IT assets, ensuring data is safely sanitized while contributing to a more circular IT lifecycle. By maximizing the reuse or responsible recycling of devices, ARS helps businesses meet sustainability goals while recovering potential value from their retired equipment. For more information, see the Asset Recovery Services offering page.
- CO2 Offset Services
Lenovo’s CO2 Offset Services offer a simple and transparent way for businesses to take tangible action on their IT footprint. By integrating CO2 offsets directly into device purchases, customers can easily support verified climate projects and track their contributions, making meaningful progress toward their sustainability goals without added complexity.
- Lenovo Certified Refurbished
Lenovo Certified Refurbished offers a cost-effective way to support IT circularity without compromising on quality and performance. Each device undergoes rigorous testing and certification, ensuring reliable performance and extending its lifecycle. With Lenovo’s trusted certification, you gain peace of mind while making a more sustainable IT choice.
Lenovo TruScale
Lenovo TruScale XaaS is your set of flexible IT services that makes everything easier. Streamline IT procurement, simplify infrastructure and device management, and pay only for what you use – so your business is free to grow and go anywhere.
Lenovo TruScale is the unified solution that gives you simplified access to:
- The industry’s broadest portfolio – from pocket to cloud – all delivered as a service
- A single-contract framework for full visibility and accountability
- The global scale to rapidly and securely build teams from anywhere
- Flexible fixed and metered pay-as-you-go models with minimal upfront cost
- The growth-driving combination of hardware, software, infrastructure, and solutions – all from one single provider with one point of accountability.
For information about Lenovo TruScale offerings that are available in your region, contact your local Lenovo sales representative or business partner.
Regulatory compliance
The SR850 server conforms to the following standards:
- Energy Star v2.1
- FCC: Verified to comply with Part 15 of the FCC Rules, Class A
- Canada ICES-003, issue 6, Class A
- UL/IEC 60950-1
- CSA C22.2 No. 60950-1
- NOM-019
- Argentina IEC60950-1
- Japan VCCI, Class A
- Australia/New Zealand AS/NZS CISPR 32, Class A; AS/NZS 60950.1
- IEC 60950-1 (CB Certificate and CB Test Report)
- China CCC (GB4943.1), GB9254 Class A, GB17625.1
- Taiwan BSMI CNS13438, Class A; CNS14336-1
- Korea KN32, Class A; KN35
- Russia, Belorussia and Kazakhstan, EAC: TP TC 004/2011(for Safety); TP TC 020/2011(for EMC)
- CE Mark (EN55032 Class A, EN60950-1, EN55024, EN61000-3-2, and EN61000-3-3)
- CISPR 32, Class A
- TUV-GS (EN60950-1 /IEC60950-1, EK1-ITB2000)
- India BIS certification
External drive enclosures
The server supports attachment to external drive enclosures using a RAID controller with external ports or a SAS host bus adapter. Adapters supported by the server are listed in the SAS adapters for external storage section.
Note: Information provided in this section is for ordering reference purposes only. For the operating system and adapter support details, refer to the interoperability matrix for a particular storage enclosure that can be found on the Lenovo Data Center Support web site:
http://datacentersupport.lenovo.com
Model | Description |
---|---|
4587HC1 | Lenovo Storage D1212 Disk Expansion Enclosure (2U enclosure with 12x LFF drive bays) |
4587HC2 | Lenovo Storage D1224 Disk Expansion Enclosure (2U enclosure with 24x SFF drive bays) |
6413HC1 | Lenovo Storage D3284 High Density Expansion Enclosure (5U enclosure with 84x LFF drive bays) |
7DAHCTO1WW | Lenovo ThinkSystem D4390 Direct Attached Storage (4U enclosure with 90x LFF drive bays) |
For details about supported drives, adapters, and cables, see the following Lenovo Press Product Guides:
- Lenovo Storage D1212 and D1224
http://lenovopress.lenovo.com/lp0512 - Lenovo Storage D3284
http://lenovopress.lenovo.com/lp0513 - Lenovo ThinkSystem D4390
https://lenovopress.lenovo.com/lp1681
External storage systems
Lenovo offers the ThinkSystem DE Series and ThinkSystem DM Series external storage systems for high-performance storage. See the DE Series and DM Series product guides for specific controller models, expansion enclosures and configuration options:
- ThinkSystem DE Series Storage
https://lenovopress.com/storage/thinksystem/de-series#rt=product-guide - ThinkSystem DM Series Storage
https://lenovopress.com/storage/thinksystem/dm-series#rt=product-guide - ThinkSystem DG Series Storage
https://lenovopress.com/storage/thinksystem/dg-series#rt=product-guide
External backup units
The server supports both USB-attached RDX backup units and SAS-attached tape drives.
The following table lists the available external SAS tape backup options.
Tip: Verify the end-to-end support of an IBM tape backup solution through the IBM System Storage Interoperation Center (SSIC): http://www.ibm.com/systems/support/storage/ssic
Part number | Description |
---|---|
External SAS tape backup drives | |
6160S6E | IBM TS2260 Tape Drive Model H6S |
6160S7E | IBM TS2270 Tape Drive Model H7S |
6160S8E | IBM TS2280 Tape Drive Model H8S |
6160S9E | IBM TS2290 Tape Drive Model H9S |
External SAS tape backup autoloaders | |
6171S6R | IBM TS2900 Tape Autoloader w/LTO6 HH SAS |
6171S7R | IBM TS2900 Tape Autoloader w/LTO7 HH SAS |
6171S8R | IBM TS2900 Tape Autoloader w/LTO8 HH SAS |
6171S9R | IBM TS2900 Tape Autoloader w/LTO9 HH SAS |
External tape backup libraries | |
6741A1F | IBM TS4300 3U Tape Library-Base Unit |
SAS backup drives for TS4300 Tape Library | |
01KP934 | LTO 6 HH SAS Drive |
01KP937 | LTO 7 HH SAS Drive |
01KP953 | LTO 8 HH SAS Drive |
02JH836 | LTO 9 HH SAS Drive |
For more information, see the list of Product Guides in the Backup units category:
https://lenovopress.com/servers/options/backup
The following table lists the external RDX backup options available.
Part number | Feature code | Description |
---|---|---|
External RDX docks | ||
4T27A10725 | B32R | ThinkSystem RDX External USB 3.0 Dock (No cartridge included with the drive) |
Cartridges | ||
7TP7A01601 | AVF8 | ThinkSystem RDX 500GB Cartridge |
7TP7A01602 | AVF1 | ThinkSystem RDX 1TB Cartridge |
7TP7A01603 | AVF0 | ThinkSystem RDX 2TB Cartridge |
7TP7A04318 | AXD1 | ThinkSystem RDX 4TB Cartridge |
For more information, see the Lenovo RDX USB 3.0 Disk Backup Solution product guide:
https://lenovopress.com/tips0894-rdx-usb-30
Top-of-rack Ethernet switches
The following table lists the Ethernet LAN switches that are offered by Lenovo.
Part number | Description |
---|---|
1 Gb Ethernet Rack switches | |
7Y810011WW | Lenovo ThinkSystem NE0152T RackSwitch (Rear to Front) |
7Z320O11WW | Lenovo ThinkSystem NE0152TO RackSwitch (Rear to Front, ONIE) |
7159BAX | Lenovo RackSwitch G7028 (Rear to Front) |
7159CAX | Lenovo RackSwitch G7052 (Rear to Front) |
7159G52 | Lenovo RackSwitch G8052 (Rear to Front) |
7165H1X | Juniper EX2300-C PoE Switch |
7165H2X | Juniper EX2300-24p PoE Switch |
1 Gb Ethernet Campus switches | |
7Z340011WW | Lenovo CE0128TB Switch (3-Year Warranty) |
7Z360011WW | Lenovo CE0128TB Switch (Limited Lifetime Warranty) |
7Z340012WW | Lenovo CE0128PB Switch (3-Year Warranty) |
7Z360012WW | Lenovo CE0128PB Switch (Limited Lifetime Warranty) |
7Z350021WW | Lenovo CE0152TB Switch (3-Year Warranty) |
7Z370021WW | Lenovo CE0152TB Switch (Limited Lifetime Warranty) |
7Z350022WW | Lenovo CE0152PB Switch (3-Year Warranty) |
7Z370022WW | Lenovo CE0152PB Switch (Limited Lifetime Warranty) |
10 Gb Ethernet switches | |
7159A1X | Lenovo ThinkSystem NE1032 RackSwitch (Rear to Front) |
7159B1X | Lenovo ThinkSystem NE1032T RackSwitch (Rear to Front) |
7Z330O11WW | Lenovo ThinkSystem NE1064TO RackSwitch (Rear to Front, ONIE) |
7159C1X | Lenovo ThinkSystem NE1072T RackSwitch (Rear to Front) |
7159CRW | Lenovo RackSwitch G8272 (Rear to Front) |
7159GR6 | Lenovo RackSwitch G8296 (Rear to Front) |
7159BR6 | Lenovo RackSwitch G8124E (Rear to Front) |
25 Gb Ethernet switches | |
7159E1X | Lenovo ThinkSystem NE2572 RackSwitch (Rear to Front) |
7Z210O21WW | Lenovo ThinkSystem NE2572O RackSwitch (Rear to Front, ONIE) |
7Z330O21WW | Lenovo ThinkSystem NE2580O RackSwitch (Rear to Front, ONIE) |
100 Gb Ethernet switches | |
7159D1X | Lenovo ThinkSystem NE10032 RackSwitch (Rear to Front) |
7Z210O11WW | Lenovo ThinkSystem NE10032O RackSwitch (Rear to Front, ONIE) |
For more information, see the list of Product Guides in the following switch categories:
- 1 Gb Ethernet switches: http://lenovopress.com/networking/tor/1gb?rt=product-guide
- 10 Gb Ethernet switches: http://lenovopress.com/networking/tor/10gb?rt=product-guide
- 25 Gb Ethernet switches: http://lenovopress.com/networking/tor/25gb?rt=product-guide
- 40 Gb Ethernet switches: http://lenovopress.com/networking/tor/40gb?rt=product-guide
- 100 Gb Ethernet switches: https://lenovopress.com/networking/tor/100Gb?rt=product-guide
Fibre Channel SAN switches
Lenovo offers the ThinkSystem DB Series of Fibre Channel SAN switches for high-performance storage expansion. See the DB Series product guides for models and configuration options:
- ThinkSystem DB Series SAN Switches:
https://lenovopress.com/storage/switches/rack#rt=product-guide
Uninterruptible power supply units
The following table lists the uninterruptible power supply (UPS) units that are offered by Lenovo.
Part number | Description |
---|---|
Rack-mounted or tower UPS units - 100-125VAC | |
7DD5A001WW | RT1.5kVA 2U Rack or Tower UPS-G2 (100-125VAC) |
55941AX | RT1.5kVA 2U Rack or Tower UPS (100-125VAC) |
55942AX | RT2.2kVA 2U Rack or Tower UPS (100-125VAC) |
7DD5A003WW | RT3kVA 2U Rack or Tower UPS-G2 (100-125VAC) |
55943AX | RT3kVA 2U Rack or Tower UPS (100-125VAC) |
Rack-mounted or tower UPS units - 200-240VAC | |
7DD5A002WW | RT1.5kVA 2U Rack or Tower UPS-G2 (200-240VAC) |
55941KX | RT1.5kVA 2U Rack or Tower UPS (200-240VAC) |
55942KX | RT2.2kVA 2U Rack or Tower UPS (200-240VAC) |
7DD5A005WW | RT3kVA 2U Rack or Tower UPS-G2 (200-240VAC) |
55943KX | RT3kVA 2U Rack or Tower UPS (200-240VAC) |
7DD5A007WW | RT5kVA 3U Rack or Tower UPS-G2 (200-240VAC) |
55945KX | RT5kVA 3U Rack or Tower UPS (200-240VAC) |
7DD5A008WW | RT6kVA 3U Rack or Tower UPS-G2 (200-240VAC) |
55946KX | RT6kVA 3U Rack or Tower UPS (200-240VAC) |
55948KX | RT8kVA 6U Rack or Tower UPS (200-240VAC) |
7DD5A00AWW | RT11kVA 6U Rack or Tower UPS-G2 (200-240VAC) |
55949KX | RT11kVA 6U Rack or Tower UPS (200-240VAC) |
55943KT† | ThinkSystem RT3kVA 2U Standard UPS (200-230VAC) (2x C13 10A, 2x GB 10A, 1x C19 16A outlets) |
55943LT† | ThinkSystem RT3kVA 2U Long Backup UPS (200-230VAC) (2x C13 10A, 2x GB 10A, 1x C19 16A outlets) |
55946KT† | ThinkSystem RT6kVA 5U UPS (200-230VAC) (2x C13 10A outlets, 1x Terminal Block output) |
5594XKT† | ThinkSystem RT10kVA 5U UPS (200-230VAC) (2x C13 10A outlets, 1x Terminal Block output) |
Rack-mounted or tower UPS units - 380-415VAC | |
55948PX | RT8kVA 6U 3:1 Phase Rack or Tower UPS (380-415VAC) |
55949PX | RT11kVA 6U 3:1 Phase Rack or Tower UPS (380-415VAC) |
† Only available in China and the Asia Pacific market.
For more information, see the list of Product Guides in the UPS category:
https://lenovopress.com/servers/options/ups
Power distribution units
The following table lists the power distribution units (PDUs) that are offered by Lenovo.
Part number |
Feature code |
Description |
ANZ
|
ASEAN
|
Brazil
|
EET
|
MEA
|
RUCIS
|
WE
|
HTK
|
INDIA
|
JAPAN
|
LA
|
NA
|
PRC
|
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
0U Basic PDUs | |||||||||||||||
4PU7A93176 | C0QH | 0U 36 C13 and 6 C19 Basic 32A 1 Phase PDU v2 | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
4PU7A93169 | C0DA | 0U 36 C13 and 6 C19 Basic 32A 1 Phase PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
4PU7A93177 | C0QJ | 0U 24 C13/C15 and 24 C13/C15/C19 Basic 32A 3 Phase WYE PDU v2 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
4PU7A93170 | C0D9 | 0U 24 C13/C15 and 24 C13/C15/C19 Basic 32A 3 Phase WYE PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
00YJ776 | ATZY | 0U 36 C13/6 C19 24A 1 Phase PDU | N | Y | Y | N | N | N | N | N | N | Y | Y | Y | N |
00YJ779 | ATZX | 0U 21 C13/12 C19 48A 3 Phase PDU | N | N | Y | N | N | N | Y | N | N | Y | Y | Y | N |
00YJ777 | ATZZ | 0U 36 C13/6 C19 32A 1 Phase PDU | Y | Y | N | Y | Y | Y | Y | Y | Y | N | N | Y | Y |
00YJ778 | AU00 | 0U 21 C13/12 C19 32A 3 Phase PDU | Y | Y | N | Y | Y | Y | Y | Y | Y | N | N | Y | Y |
0U Switched and Monitored PDUs | |||||||||||||||
4PU7A93181 | C0QN | 0U 21 C13/C15 and 21 C13/C15/C19 Switched and Monitored 48A 3 Phase Delta PDU v2 (60A derated) | N | Y | N | N | N | N | N | Y | N | Y | N | Y | N |
4PU7A93174 | C0D5 | 0U 21 C13/C15 and 21 C13/C15/C19 Switched and Monitored 48A 3 Phase Delta PDU (60A derated) | N | Y | N | Y | N | N | Y | Y | N | N | N | Y | N |
4PU7A93178 | C0QK | 0U 20 C13 and 4 C19 Switched and Monitored 32A 1 Phase PDU v2 | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
4PU7A93171 | C0D8 | 0U 20 C13 and 4 C19 Switched and Monitored 32A 1 Phase PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
4PU7A93182 | C0QP | 0U 18 C13/C15 and 18 C13/C15/C19 Switched and Monitored 63A 3 Phase WYE PDU v2 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
4PU7A93175 | C0CS | 0U 18 C13/C15 and 18 C13/C15/C19 Switched and Monitored 63A 3 Phase WYE PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
4PU7A93180 | C0QM | 0U 18 C13/C15 and 18 C13/C15/C19 Switched and Monitored 32A 3 Phase WYE PDU v2 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
4PU7A93173 | C0D6 | 0U 18 C13/C15 and 18 C13/C15/C19 Switched and Monitored 32A 3 Phase WYE PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
4PU7A93179 | C0QL | 0U 16 C13/C15 and 16 C13/C15/C19 Switched and Monitored 24A 1 Phase PDU v2 (30A derated) | N | Y | N | N | N | N | N | Y | N | Y | N | Y | N |
4PU7A93172 | C0D7 | 0U 16 C13/C15 and 16 C13/C15/C19 Switched and Monitored 24A 1 Phase PDU(30A derated) | N | Y | N | Y | N | N | Y | Y | N | N | N | Y | N |
00YJ783 | AU04 | 0U 12 C13/12 C19 Switched and Monitored 48A 3 Phase PDU | N | N | Y | N | N | N | Y | N | N | Y | Y | Y | N |
00YJ781 | AU03 | 0U 20 C13/4 C19 Switched and Monitored 24A 1 Phase PDU | N | N | Y | N | Y | N | Y | N | N | Y | Y | Y | N |
00YJ782 | AU02 | 0U 18 C13/6 C19 Switched and Monitored 32A 3 Phase PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | N | Y |
00YJ780 | AU01 | 0U 20 C13/4 C19 Switched and Monitored 32A 1 Phase PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | N | Y |
1U Switched and Monitored PDUs | |||||||||||||||
4PU7A90808 | C0D4 | 1U 18 C19/C13 Switched and monitored 48A 3P WYE PDU V2 ETL | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
4PU7A81117 | BNDV | 1U 18 C19/C13 switched and monitored 48A 3P WYE PDU - ETL | N | N | N | N | N | N | N | N | N | N | N | Y | N |
4PU7A90809 | C0DE | 1U 18 C19/C13 Switched and monitored 48A 3P WYE PDU V2 CE | N | N | N | N | N | Y | Y | N | N | N | N | N | N |
4PU7A81118 | BNDW | 1U 18 C19/C13 switched and monitored 48A 3P WYE PDU - CE | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | N | Y |
4PU7A90810 | C0DD | 1U 18 C19/C13 Switched and monitored 80A 3P Delta PDU V2 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
4PU7A77467 | BLC4 | 1U 18 C19/C13 Switched and Monitored 80A 3P Delta PDU | N | N | N | N | N | N | N | N | N | Y | N | Y | N |
4PU7A90811 | C0DC | 1U 12 C19/C13 Switched and monitored 32A 3P WYE PDU V2 | N | N | N | N | N | Y | Y | N | N | N | N | N | N |
4PU7A77468 | BLC5 | 1U 12 C19/C13 switched and monitored 32A 3P WYE PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
4PU7A90812 | C0DB | 1U 12 C19/C13 Switched and monitored 60A 3P Delta PDU V2 | N | N | N | N | N | N | N | N | N | Y | N | N | N |
4PU7A77469 | BLC6 | 1U 12 C19/C13 switched and monitored 60A 3P Delta PDU | N | N | N | N | N | N | N | N | N | N | N | Y | N |
46M4002 | 5896 | 1U 9 C19/3 C13 Switched and Monitored DPI PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
46M4004 | 5894 | 1U 12 C13 Switched and Monitored DPI PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
46M4003 | 5897 | 1U 9 C19/3 C13 Switched and Monitored 60A 3 Phase PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
46M4005 | 5895 | 1U 12 C13 Switched and Monitored 60A 3 Phase PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
1U Ultra Density Enterprise PDUs (9x IEC 320 C13 + 3x IEC 320 C19 outlets) | |||||||||||||||
71763NU | 6051 | Ultra Density Enterprise C19/C13 PDU 60A/208V/3PH | N | N | Y | N | N | N | N | N | N | Y | Y | Y | N |
71762NX | 6091 | Ultra Density Enterprise C19/C13 PDU Module | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
1U C13 Enterprise PDUs (12x IEC 320 C13 outlets) | |||||||||||||||
39M2816 | 6030 | DPI C13 Enterprise PDU Plus Module (WW) | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
39Y8941 | 6010 | DPI C13 Enterprise PDU Module (WW) | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
1U C19 Enterprise PDUs (6x IEC 320 C19 outlets) | |||||||||||||||
39Y8948 | 6060 | DPI C19 Enterprise PDU Module (WW) | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
39Y8923 | 6061 | DPI Three-phase 60A/208V C19 Enterprise PDU (US) | N | N | Y | N | N | N | Y | N | N | N | Y | Y | N |
1U Front-end PDUs (3x IEC 320 C19 outlets) | |||||||||||||||
39Y8938 | 6002 | DPI Single-phase 30A/120V Front-end PDU (US) | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
39Y8939 | 6003 | DPI Single-phase 30A/208V Front-end PDU (US) | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
39Y8934 | 6005 | DPI Single-phase 32A/230V Front-end PDU (International) | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
39Y8940 | 6004 | DPI Single-phase 60A/208V Front-end PDU (US) | Y | N | Y | Y | Y | Y | Y | N | N | Y | Y | Y | N |
39Y8935 | 6006 | DPI Single-phase 63A/230V Front-end PDU (International) | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
1U NEMA PDUs (6x NEMA 5-15R outlets) | |||||||||||||||
39Y8905 | 5900 | DPI 100-127V NEMA PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Line cords for 1U PDUs that ship without a line cord | |||||||||||||||
40K9611 | 6504 | 4.3m, 32A/380-415V, EPDU/IEC 309 3P+N+G 3ph wye (non-US) Line Cord | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
40K9612 | 6502 | 4.3m, 32A/230V, EPDU to IEC 309 P+N+G (non-US) Line Cord | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
40K9613 | 6503 | 4.3m, 63A/230V, EPDU to IEC 309 P+N+G (non-US) Line Cord | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
40K9614 | 6500 | 4.3m, 30A/208V, EPDU to NEMA L6-30P (US) Line Cord | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
40K9615 | 6501 | 4.3m, 60A/208V, EPDU to IEC 309 2P+G (US) Line Cord | N | N | Y | N | N | N | Y | N | N | Y | Y | Y | N |
40K9617 | 6505 | 4.3m, 32A/230V, Souriau UTG Female to AS/NZ 3112 (Aus/NZ) Line Cord | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
40K9618 | 6506 | 4.3m, 32A/250V, Souriau UTG Female to KSC 8305 (S. Korea) Line Cord | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
For more information, see the Lenovo Press documents in the PDU category:
https://lenovopress.com/servers/options/pdu
Rack cabinets
The following table lists the supported rack cabinets.
Model | Description |
---|---|
93072RX | 25U Standard Rack (1000mm) |
93072PX | 25U Static S2 Standard Rack (1000mm) |
7D6DA007WW | ThinkSystem 42U Onyx Primary Heavy Duty Rack Cabinet (1200mm) |
7D6DA008WW | ThinkSystem 42U Pearl Primary Heavy Duty Rack Cabinet (1200mm) |
7D6EA009WW | ThinkSystem 48U Onyx Primary Heavy Duty Rack Cabinet (1200mm) |
7D6EA00AWW | ThinkSystem 48U Pearl Primary Heavy Duty Rack Cabinet (1200mm) |
1410O42 | Lenovo EveryScale 42U Onyx Heavy Duty Rack Cabinet |
1410P42 | Lenovo EveryScale 42U Pearl Heavy Duty Rack Cabinet |
1410O48 | Lenovo EveryScale 48U Onyx Heavy Duty Rack Cabinet |
1410P48 | Lenovo EveryScale 48U Pearl Heavy Duty Rack Cabinet |
93604PX | 42U 1200mm Deep Dynamic Rack |
93614PX | 42U 1200mm Deep Static Rack |
93634PX | 42U 1100mm Dynamic Rack |
93634EX | 42U 1100mm Dynamic Expansion Rack |
93074RX | 42U Standard Rack (1000mm) |
93084PX | 42U Enterprise Rack |
93084EX | 42U Enterprise Expansion Rack |
For specifications about these racks, see the Lenovo Rack Cabinet Reference, available from:
https://lenovopress.com/lp1287-lenovo-rack-cabinet-reference
For more information, see the list of Product Guides in the Rack cabinets category:
https://lenovopress.com/servers/options/racks
KVM console options
The following table lists the supported KVM consoles.
Part number | Description |
---|---|
Consoles | |
4XF7A84188 | ThinkSystem 18.5" LCD Console (with US English keyboard) |
4XF7A73009 | ThinkSystem 18.5" LCD console (with US English keyboard) |
17238BX | 1U 18.5" Standard Console (without keyboard - see the next table) |
The following table lists the keyboards supported with the 1U 18.5" Standard Console (now withdrawn).
Note: These keyboards are not supported with the ThinkSystem 18.5" LCD Console.
Part number | Description |
---|---|
7ZB7A05469 | ThinkSystem Keyboard w/ Int.Pointing Device USB - Arabic 253 RoHS v2 |
7ZB7A05468 | ThinkSystem Keyboard w/ Int. Pointing Device USB - Belg/UK 120 RoHS v2 |
7ZB7A05206 | ThinkSystem Keyboard w/ Int. Pointing Device USB - Czech 489 RoHS v2 |
7ZB7A05207 | ThinkSystem Keyboard w/ Int. Pointing Device USB - Danish 159 RoHS v2 |
7ZB7A05208 | ThinkSystem Keyboard w/ Int. Pointing Device USB - Dutch 143 RoHS v2 |
7ZB7A05210 | ThinkSystem Keyboard w/ Int. Pointing Device USB - Fr/Canada 445 RoHS v2 |
7ZB7A05209 | ThinkSystem Keyboard w/ Int. Pointing Device USB - French 189 RoHS v2 |
7ZB7A05211 | ThinkSystem Keyboard w/ Int. Pointing Device USB - German 129 RoHS v2 |
7ZB7A05212 | ThinkSystem Keyboard w/ Int. Pointing Device USB - Greek 219 RoHS v2 |
7ZB7A05213 | ThinkSystem Keyboard w/ Int. Pointing Device USB - Hebrew 212 RoHS v2 |
7ZB7A05214 | ThinkSystem Keyboard w/ Int. Pointing Device USB - Hungarian 208 RoHS v2 |
7ZB7A05215 | ThinkSystem Keyboard w/ Int. Pointing Device USB - Italian 141 RoHS v2 |
7ZB7A05216 | ThinkSystem Keyboard w/ Int. Pointing Device USB - Japanese 194 RoHS v2 |
7ZB7A05217 | ThinkSystem Keyboard w/ Int. Pointing Device USB - Korean 413 RoHS v2 |
7ZB7A05218 | ThinkSystem Keyboard w/ Int. Pointing Device USB - LA Span 171 RoHS v2 |
7ZB7A05219 | ThinkSystem Keyboard w/ Int. Pointing Device USB - Norwegian 155 RoHS v2 |
7ZB7A05220 | ThinkSystem Keyboard w/ Int. Pointing Device USB - Polish 214 RoHS v2 |
7ZB7A05221 | ThinkSystem Keyboard w/ Int. Pointing Device USB - Portugese 163 RoHS v2 |
7ZB7A05222 | ThinkSystem Keyboard w/ Int. Pointing Device USB - Russian 441 RoHS v2 |
7ZB7A05223 | ThinkSystem Keyboard w/ Int. Pointing Device USB - Slovak 245 RoHS v2 |
7ZB7A05231 | ThinkSystem Keyboard w/ Int. Pointing Device USB - Slovenian 234 RoHS v2 |
7ZB7A05224 | ThinkSystem Keyboard w/ Int. Pointing Device USB - Spanish 172 RoHS v2 |
7ZB7A05225 | ThinkSystem Keyboard w/ Int. Pointing Device USB - Swed/Finn 153 RoHS v2 |
7ZB7A05226 | ThinkSystem Keyboard w/ Int. Pointing Device USB - Swiss F/G 150 RoHS v2 |
7ZB7A05227 | ThinkSystem Keyboard w/ Int. Pointing Device USB - Thai 191 RoHS v2 |
7ZB7A05467 | ThinkSystem Keyboard with Int. Pointing Device USB - Trad Chinese/US 467 RoHS v2 |
7ZB7A05228 | ThinkSystem Keyboard w/ Int. Pointing Device USB - Turkish 179 RoHS v2 |
7ZB7A05229 | ThinkSystem Keyboard w/ Int. Pointing Device USB - UK Eng 166 RoHS v2 |
7ZB7A05470 | ThinkSystem Keyboard w/ Int. Pointing Device USB - US Eng 103P RoHS v2 |
7ZB7A05230 | ThinkSystem Keyboard w/ Int. Pointing Device USB - US Euro 103P RoHS v2 |
The following table lists the available KVM switches and the options that are supported with them.
Part number | Description |
---|---|
KVM Console switches | |
1754D1T | ThinkSystem Digital 2x1x16 KVM Switch (DVI video output port) |
1754A1T | ThinkSystem Analog 1x8 KVM Switch (DVI video output port) |
1754D2X | Global 4x2x32 Console Manager (GCM32) |
1754D1X | Global 2x2x16 Console Manager (GCM16) |
1754A2X | Local 2x16 Console Manager (LCM16) |
1754A1X | Local 1x8 Console Manager (LCM8) |
Cables for ThinkSystem Digital and Analog KVM Console switches | |
4X97A11108 | ThinkSystem VGA to DVI Conversion Cable |
4X97A11109 | ThinkSystem Single-USB Conversion Cable for Digital KVM |
4X97A11107 | ThinkSystem Dual-USB Conversion Cable for Digital KVM |
4X97A11106 | ThinkSystem USB Conversion Cable for Analog KVM |
Cables for GCM and LCM Console switches | |
43V6147 | Single Cable USB Conversion Option (UCO) |
39M2895 | USB Conversion Option Pack |
46M5383 | Virtual Media Conversion Option Gen2 (VCO2) |
46M5382 | Serial Conversion Option (SCO) |
For more information, see the list of Product Guides in the KVM Switches and Consoles category:
http://lenovopress.com/servers/options/kvm
Lenovo Financial Services
Why wait to obtain the technology you need now? No payments for 90 days and predictable, low monthly payments make it easy to budget for your Lenovo solution.
- Flexible
Our in-depth knowledge of the products, services and various market segments allows us to offer greater flexibility in structures, documentation and end of lease options.
- 100% Solution Financing
Financing your entire solution including hardware, software, and services, ensures more predictability in your project planning with fixed, manageable payments and low monthly payments.
- Device as a Service (DaaS)
Leverage latest technology to advance your business. Customized solutions aligned to your needs. Flexibility to add equipment to support growth. Protect your technology with Lenovo's Premier Support service.
- 24/7 Asset management
Manage your financed solutions with electronic access to your lease documents, payment histories, invoices and asset information.
- Fair Market Value (FMV) and $1 Purchase Option Leases
Maximize your purchasing power with our lowest cost option. An FMV lease offers lower monthly payments than loans or lease-to-own financing. Think of an FMV lease as a rental. You have the flexibility at the end of the lease term to return the equipment, continue leasing it, or purchase it for the fair market value. In a $1 Out Purchase Option lease, you own the equipment. It is a good option when you are confident you will use the equipment for an extended period beyond the finance term. Both lease types have merits depending on your needs. We can help you determine which option will best meet your technological and budgetary goals.
Ask your Lenovo Financial Services representative about this promotion and how to submit a credit application. For the majority of credit applicants, we have enough information to deliver an instant decision and send a notification within minutes.
Related product families
Product families related to this document are the following:
Trademarks
Lenovo and the Lenovo logo are trademarks or registered trademarks of Lenovo in the United States, other countries, or both. A current list of Lenovo trademarks is available on the Web at https://www.lenovo.com/us/en/legal/copytrade/.
The following terms are trademarks of Lenovo in the United States, other countries, or both:
Lenovo®
AnyBay®
ServerProven®
System x®
ThinkAgile®
ThinkServer®
ThinkSystem®
XClarity®
The following terms are trademarks of other companies:
AMD is a trademark of Advanced Micro Devices, Inc.
Intel®, Intel Optane®, and Xeon® are trademarks of Intel Corporation or its subsidiaries.
Linux® is the trademark of Linus Torvalds in the U.S. and other countries.
Microsoft®, ActiveX®, PowerShell, Windows PowerShell®, Windows Server®, and Windows® are trademarks of Microsoft Corporation in the United States, other countries, or both.
Other company, product, or service names may be trademarks or service marks of others.