Abstract
Lenovo ThinkSystem DM7000F is a scalable, unified, all flash storage system that is designed to provide high performance, simplicity, capacity, security, and high availability for large enterprises. Powered by the ONTAP software, ThinkSystem DM7000F delivers enterprise-class storage management capabilities with a wide choice of host connectivity options, flexible drive configurations, and enhanced data management features.
This product guide provides essential technical and pre-sales information on the Lenovo ThinkSystem DM7000F Unified Flash Storage Array, its key features and specifications, components and options, and configuration guidelines.
This guide is intended for technical specialists, sales specialists, sales engineers, and IT architects who want to learn more about the ThinkSystem DM7000F Unified Flash Storage Array and consider its use in their solutions.
Withdrawn from marketing: The ThinkSystem DM7000F is now withdrawn from marketing. The suggested replacement is the DM7100F as described in the DM7100F product guide, https://lenovopress.com/lp1271-thinksystem-dm7100f-unified-all-flash-storage-array
How customers use ThinkSystem DM Series
Case Study: Aiways Automotive
Harnessing smart factory solutions to build the next generation of eco-friendly electric vehicles.
As a brand-new start-up breaking into the ultra-competitive automotive market, AIWAYS aims to close the gap with technology. By moving to a scalable, secure and high-performance IT infrastructure from Lenovo, AIWAYS keeps its smart factories running 24/7.
Founded as a start-up in 2017 and headquartered in Shanghai, China, AIWAYS is a designer and manufacturer of electric cars. With an annual production capacity of 300,000 units, AIWAYS operates factories in the cities of Shangrao and Changshu, research and development (R&D) sites across China and Europe, and a laboratory in Detroit, USA.
How customers use ThinkSystem DM Series
Case Study: Wuhan Zhongbang Bank
Sustaining impressive growth rates with highly available, targeted banking services.
Wuhan Zhongbang Bank (Z-Bank) is carving a niche for itself in the Chinese banking sector by focusing on small and micro businesses (SMEs). To expand its market share of 17 million customers and counting, the bank built new high-availability, high-performance data center infrastructure based on Lenovo servers and storage. By enabling superb service continuity 24/7 and rapid innovation, Z-Bank is inspiring loyalty from existing customers and attracting new business.
As a relatively new bank, Z-Bank is reinforcing its position in the competitive Chinese banking industry by differentiating itself from the competition. The bank has found success in targeting individuals and small and micro businesses (SMEs), rapidly growing its customer base to 17 million in merely 3 years.
How customers use ThinkSystem DM Series
Case Study: PGS
How PGS overhauled operations with the Remote Visualization solution from Lenovo, NVIDIA, Red Hat, Mechdyne, Leostream, and PCPC Direct, ensuring that the interpretation team can always collaborate and work efficiently.
How customers use ThinkSystem DM Series
Case Study: Shandong Shida Shenghua Chemical Group
Shandong Shida Shenghua Chemical Group is at the forefront of the green technology revolution, playing a key role in both the production of organic chemical products and research into new energy sources.
To safeguard its vital business and research data, the company migrated its mission-critical systems to a new infrastructure powered by Lenovo ThinkSystem SR860 servers, with data protection and disaster recovery from NetApp ONTAP Select
How customers use ThinkSystem DM Series
Case Study: Jolera
Driving double-digit business growth with an innovative cloud offering.
How Jolera used Lenovo ThinkSystem storage and servers, powered by 2nd Gen Intel® Xeon® Scalable processors, to drive its expansion in Europe by delivering enterprise-class cloud services with a more predictable and cost-effective billing model.
How customers use ThinkSystem DM Series
Case Study: DETASAD
Enabling business transformation in Saudi Arabia and beyond.
How DETASAD augmented its private cloud platform with Lenovo ThinkSystem servers, powered by 2nd Gen Intel® Xeon® Scalable processors, and Lenovo ThinkSystem storage, paving the way for growth into valuable new markets.
How customers use ThinkSystem DM Series
Case Study: Hefei Environmental Protection Bureau
How Hefei Environmental Protection Bureau stops pollution in its tracks with high-performance Lenovo infrastructure for real-time monitoring.
How customers use ThinkSystem DM Series
Case Study: Enjoy International Tourism Resort
Delivering outstanding visitor experiences: how the Enjoy International Tourism Resort uses Lenovo ThinkSystem solutions to ensure an exceptional experience for every guest.
How customers use ThinkSystem DM Series
Case Study: Zhejiang Meteorological Service
Mitigating the impact of extreme weather:
How Zhejiang Meteorological Service uses Lenovo ThinkSystem solutions to enable more efficient distribution of forecasts and weather services.
How customers use ThinkSystem DM Series
Case Study: Qilu Hospital of Shandong University
Driving digital services to enhance patient outcomes:
How Shandong University Qilu Hospital embraced a hyperconverged infrastructure solution from Lenovo and Nutanix, powered by 2nd Gen Intel® Xeon® Scalable processors, to support its next-generation digital healthcare services.
How customers use ThinkSystem DM Series
Case Study: Fourth Affiliated Hospital of Nanjing Medical University
Enabling gold-standard healthcare services:
How the Fourth Affiliated Hospital of Nanjing Medical University uses a hyperconverged infrastructure from Lenovo and VMware and Lenovo ThinkSystem solutions to support high-quality, high-availability healthcare, promoting better patient outcomes.
How customers use ThinkSystem DM Series
Case Study: Xiamen Tungsten Company Ltd.
Developing next-generation manufacturing operations:
How Xiamen Tungsten uses Lenovo ThinkSystem solutions to support long-term business growth and adopt cutting-edge smart manufacturing processes.
How customers use ThinkSystem DM Series
Case Study: GuoGuang Electric Company
Keeping China connected throughout the pandemic with world-class audio technology:
How GuoGuang Electric Company used Lenovo ThinkSystem servers to capitalize on surging demand for speakers and music production technologies.
How customers use ThinkSystem DM Series
Case Study: Xinjiang Autonomous Region Tax Bureau
Strengthening tax administration with cutting-edge technologies:
How Xinjiang Autonomous Region Tax Bureau uses Lenovo ThinkSystem storage solutions to support robust tax governance and smart taxation policies—contributing to better services for citizens.
How customers use ThinkSystem DM Series
Case Study: Jiaxing Kaiyi Hospital
Smart hospital lifts patient services to new heights:
How Jiaxing Kaiyi Hospital used Lenovo ThinkAgile HX and ThinkSystem solutions to deliver outstanding patient experiences at a brand-new, data-driven healthcare center.
How customers use ThinkSystem DM Series
Case Study: Shanghai Junai Rehabilitation Hospital
Delivering always-on access to vital healthcare systems:
How Shanghai Junai Rehabilitation Hospital used a highly available and cost-effective hyperconverged infrastructure from Lenovo and Nutanix to support its demanding digital healthcare systems, enabling high-quality patient experiences.
How customers use ThinkSystem DM Series
Case Study: SANY Group
Staying a step ahead of global competitors by accelerating innovation.
How SANY Group uses Lenovo ThinkSystem SR650 servers, powered by NVIDIA® T4 GPUs, with Lenovo ThinkSystem DM7000H storage arrays to support the development of next-generation construction equipment and power smarter business processes.
How customers use ThinkSystem DM Series
Case Study: Hansoh Pharma
Accelerating pioneering pharmaceutical research and development with a high-performance, high-availability IT platform.
How customers use ThinkSystem DM Series
Case Study: Jining No. 1 People’s Hospital
Ensuring high-quality clinical care with an IT architecture that complies with national medical data standards.
How customers use ThinkSystem DM Series
Case Study: Nanjing Stomatological Hospital Medical School of Nanjing University
Supporting vital medical research and patient care with an agile, resilient hyperconverged platform.
How customers use ThinkSystem DM Series
Case Study: FC Internazionale Milano
Helping football fans get closer to the action on and off the pitch:
How FC Internazionale Milano uses Lenovo data center and PC technology to enhance digital campaigns, boost innovation, drive smarter fan engagement initiatives, and improve post-game analyses.
How customers use ThinkSystem DM Series
Case Study: Shangrao City Fifth People’s Hospital
Ensuring fast, non-stop access to critical healthcare systems with resilient, high-performance storage.
How customers use ThinkSystem DM Series
Case Study: Ning'er County People's Hospital
Bringing enhanced healthcare services to rural communities using highly available IT infrastructure from Lenovo.
How customers use ThinkSystem DM Series
Case Study: EGing PV
Pioneering the development of next-generation renewable energy technologies.
How customers use ThinkSystem DM Series
Case Study: HUECK Group
Getting ready for future business challenges and hybrid cloud architectures:
How manufacturer HUECK Group used Lenovo all flash storage and servers, powered by 2nd Gen Intel® Xeon® Scalable processors, to modernize its business.
How customers use ThinkSystem DM Series
Case Study: Bank of Quanzhou
Strengthening security and enhancing productivity with a virtual desktop environment powered by Lenovo.
How customers use ThinkSystem DM Series
Case Study: FIYTA
Driving the design of stylish smart watches with Lenovo smarter infrastructure solutions.
How customers use ThinkSystem DM Series
Case Study: Henan Zhongtian High-Tech Smart Technology Co, Ltd
Protecting highway toll revenues and enabling data-driven infrastructure projects with Lenovo.
How customers use ThinkSystem DM Series
Case Study: Wuqi County People's Hospital
Improving patient care delivery with a major infrastructure upgrade.
How customers use ThinkSystem DM Series
Case Study: Infosel
Unlocking new opportunities for investors:
How Infosel used a new cloud platform, built on Lenovo ThinkSystem SR570 servers and DM Series storage, to run its cutting-edge trading application with greater efficiency and agility.
How customers use ThinkSystem DM Series
Case Study: Linyi City Government
Lifting public services to new heights:
How Linyi City Government used a hyperconverged infrastructure platform from Lenovo and Nutanix to modernize and improve its e-government cloud environment.
How customers use ThinkSystem DM Series
Case Study: ShanghaiTech University
Developing the next generation of integrated circuits:
How ShanghaiTech University powers cutting-edge research into integrated circuit design with a high-performance design simulation platform based on Lenovo ThinkSystem SD530 servers and 2nd Gen Intel® Xeon® Scalable processors.
How customers use ThinkSystem DM Series
Case Study: Institut de Physique du Globe de Paris
Supporting world-changing research:
How the Institut de Physique du Globe de Paris uses Lenovo ThinkSystem servers, powered by AMD EPYC™ processors, to boost performance 5x versus the previous supercomputer, for pioneering earth and planetary science research.
How customers use ThinkSystem DM Series
Case Study: Nanjing Qingao Shelter Hospital
Treating more patients in a COVID surge.
How customers use ThinkSystem DM Series
Case Study: Fulnex
Bringing industrial robots to global clients.
How customers use ThinkSystem DM Series
Case Study: Huzhou Central Hospital
Empowering people to better manage chronic conditions.
How customers use ThinkSystem DM Series
Case Study: Jinan Children’s Hospital
How customers use ThinkSystem DM Series
Case Study: Zhongda Hospital Southeast University
Giving medical imaging data a new lease on life.
How customers use ThinkSystem DM Series
Case Study: WIMBERGER Group
Building business IT on a strong foundation:
Finding the perfect balance between performance and cost-efficiency with robust and fast Lenovo solutions.
How customers use ThinkSystem DM Series
Case Study: KOMSCO
Bringing the cloud in-house:
To support new digital offerings, KOMSCO was using computing and storage resources from a public cloud service provider. Over time, service levels were falling, yet at the same time the fees were rising. KOMSCO chose to migrate to an on-premises private cloud running on Lenovo ThinkAgile VX 7000 Series hyperconverged appliances with integrated VMware vSAN™ software. This hyperconverged solution from Lenovo and VMware has enhanced the performance and stability of KOMSCO’s systems while improving the ease of operation. KOMSCO also benefits from significant cost savings, and can now flexibly re-assign resources as workload priorities change.
How customers use ThinkSystem DM Series
Case Study: Bringbuys Cloud
A better way to grow across borders:
Bringbuys Cloud upgrades its cross-border e-commerce platform with a hyperconverged infrastructure (HCI) from Lenovo and VMware, giving clients a powerful, secure, and flexible all-in-one solution to simplify operations and sell internationally.
How customers use ThinkSystem DM Series
Case Study: Zhengzhou Second Hospital
Providing millions of patients with high-quality healthcare:
Clinicians at Zhengzhou Second Hospital rely on vast amounts of data to deliver excellent care. With patient numbers rising, the hospital scaled the IT infrastructure underpinning its services with Lenovo ThinkSystem SR860 servers—delivering greater agility and strengthening business continuity.
How customers use ThinkSystem DM Series
Case Study: Municipality of São Leopoldo
Delivering digital services citizens can rely on
The municipality of São Leopoldo takes citizen services to the next level by upgradingits IT, backed bya new Lenovo data center infrastructure powered by Intel® Xeon® Scalable processors.
How customers use ThinkSystem DM Series
Case Study: Shimane Bank
Building a future-proof banking infrastructure
Japan’s Shimane Bank works with Lenovo Professional Services to migrate swiftly and smoothly to a new virtual infrastructure, running on reliable Lenovo ThinkSystem servers and storage powered by Intel® Xeon® Scalable processors.
How customers use ThinkSystem DM Series
Case Study: Jincheng General Hospital
Modernizing IT to support safe and effective care
Jincheng General Hospital teamed up with Lenovo to centralize and modernize its IT infrastructure. With a virtualized, highly available architecture based on Lenovo ThinkSystem servers and storage, powered by Intel® Xeon® Scalable processors, the hospital can break down information silos, cut costs and complexity, and—crucially—empower staff to provide a better patient experience.
How customers use ThinkSystem DM Series
Case Study: East-West Gate Intermodal Terminal Hungary
Facilitating trade along the New Silk Road
The East-West Gate Intermodal Terminal (EWG) in Fényeslitke, Hungary is Europe’s largest smart railway logistics terminal, and serves as the western gateway to the New Silk Road. Working with Lenovo and Kontron Hungary Kft, EWG built a state-of-the-art data center to power operations and ensure the smooth passage of freight traffic between Europe and Asia.
How customers use ThinkSystem DM Series
Case Study: Xinyi Hospital of Traditional Chinese Medicine (XHTCM)
Delivering world-class medical services
To facilitate a move to a new location, XHTCM built a brand-new data center and disaster recovery site from the ground up with Lenovo ThinkSystem servers, powered by Intel® Xeon® Scalable processors. Since the move, the hospital has achieved always-on availability for critical life-saving systems and applications.
How customers use ThinkSystem DM Series
Case Study: Sunpole Co., Ltd
How customers use ThinkSystem DM Series
Case Study: Writtle University College
Advancing knowledge in land-based industries
Writtle University College delivers unique learning experiences through new audio-visual capabilities, supported by high-performance Lenovo and VMware solutions.
How customers use ThinkSystem DM Series
Case Study: Join-Cheer Software Company
Supercharging research and development
Leading software developer Join-Cheer Software Company replaced its legacy server and storage systems with high-performance Lenovo ThinkSystem SR650 V2 servers and Lenovo ThinkSystem DM5000H storage arrays—cutting total cost of ownership by 30% and accelerating R&D activities.
How customers use ThinkSystem DM Series
Case Study: Utah Hospital
Empowering clinicians with faster insights to deliver top-quality healthcare
A Utah hospital reduces response times for critical systems dramatically with Lenovo ThinkSystem storage, helping clinicians deliver outstanding patient care round-the-clock.
Introduction
Lenovo ThinkSystem DM7000F is a scalable, unified, all flash storage system that is designed to provide high performance, simplicity, capacity, security, and high availability for large enterprises. Powered by the ONTAP software, ThinkSystem DM7000F delivers enterprise-class storage management capabilities with a wide choice of host connectivity options, flexible drive configurations, and enhanced data management features, including support for NVMe over Fabrics. The ThinkSystem DM7000F is a perfect fit for a wide range of enterprise workloads, including big data and analytics, artificial intelligence, engineering and design, hybrid clouds, and other storage I/O-intensive applications.
ThinkSystem DM7000F models are 3U rack-mount controller enclosures that include two controllers, and 256 GB RAM and 16 GB battery-backed NVRAM (128 GB RAM and 8 GB NVRAM per controller). Universal 1/10 GbE NAS/iSCSI or 4/8/16 Gb Fibre Channel (FC) ports and 1/10 GbE RJ-45 ports provide base host connectivity, with an option for additional 1/10 GbE or 40 GbE NAS/iSCSI, or 8/16/32 Gb FC connections with the adapter cards.
A single ThinkSystem DM7000F Storage Array scales up to 384 SFF solid-state drives (SSDs) with the attachment of Lenovo ThinkSystem DM240S 2U24 SFF Expansion Enclosures.
Figure 1. Lenovo ThinkSystem DM7000F
Up to 12 DM7000F Storage Arrays can be combined into a clustered system in a NAS environment, or up to 6 DM7000F Storage Arrays can be combined into a clustered system in a SAN environment.
Did you know?
The ThinkSystem DM7000F offers end-to-end NVMe storage connectivity with NVMe over Fabrics (NVMeOF) and NVMe drives by implementing NVMe/FC with 32 Gb Fibre Channel host interfaces.
A single DM7000F scales up to 5.89 PB of raw storage capacity. A cluster of the DM7000F storage systems scales up to 70.7 PB for NAS or up to 35.3 PB for SAN environments.
The DM7000F offers unified file and block storage connectivity with support for 1 GbE, 10 GbE, and 40 GbE NAS and iSCSI, and 8 Gb, 16 Gb, and 32 Gb Fibre Channel, and 32 Gb NVMe/FC protocols at the same time.
Key features
The ThinkSystem DM7000F offers the following key features and benefits:
- All-flash array capabilities to meet the demand for higher speed storage and provide higher IOPs and bandwidth with lower power usage and total cost of ownership than hybrid or HDD-based solutions.
- Scalable storage with dual active/active controller configurations for availability and performance.
- NVMe over Fabrics helps achieve up to two times higher performance at a half of the latency.
- Improved performance and data protection with RAID-DP and RAID-TEC, as well as support for traditional RAID 4.
- Flexible host connectivity to match diverse client needs with support for unified NAS and SAN storage protocols, including 1/10 GbE and 40 GbE NAS and iSCSI, 8/16/32 Gb Fibre Channel, and 32 Gb NVMe over Fibre Channel (NVMe/FC).
- 12 Gb SAS drive-side connectivity with multipathing with up to 24x 2.5-inch small form factor (SFF) drives in the 2U24 SFF expansion enclosures.
- Scalability to up to 384 SFF drives with the attachment of the ThinkSystem DM240S 2U24 SFF expansion enclosures to satisfy growing needs for storage capacity and performance.
- A rich set of standard storage management functions available at no extra cost, including snapshots, volume copy, quality of service, thin provisioning, compression, deduplication, encryption, disk-based backup, application- and virtual machine-aware backup, quick data recovery, clustering, synchronous replication, and asynchronous replication.
- Optional licensed functions, including WORM (write once, read many) data protection (SnapLock) and object storage tiering (FabricPool).
- Scale-out clustering of up to 12 ThinkSystem DM Series storage systems for NAS connectivity or up to six DM Series storage systems for SAN connectivity.
- Intuitive, web-based GUI for easy system setup and management.
- Lenovo XClarity support for centralized systems management of Lenovo x86 servers, switches, and storage, which provides automated agent-less discovery, inventory, monitoring, and additional platform-specific functions across multiple systems.
- Designed for 99.9999% availability with redundant hot-swap components, including controllers and I/O modules, power supplies, and non-disruptive firmware upgrades.
- Certified Enterprise Storage for SAP HANA Tailored Data center Integration (TDI).
- Certified storage for Oracle VM.
- Certified storage for Citrix XenServer: http://hcl.xenserver.org/storage/910/Lenovo_DM_Series.
The ThinkSystem DM7000F supports attachment of up to 16 ThinkSystem DM240S 2U24 SFF expansion enclosures. The expansion enclosures support 2.5-inch capacity-optimized (1 drive write per day [DWD]) 960 GB, 3.84 TB, 7.68 TB, and 15.36 TB SAS hot-swap SSDs. More drives and expansion enclosures are designed to be dynamically added with virtually no downtime, which helps to quickly and seamlessly respond to ever-growing capacity demands.
The ThinkSystem DM7000F offers high levels of system and data availability with the following features:
- Dual-active controllers (high availability pair) with automatic load balancing and failover
- Mirrored, battery-backed controller NVRAM
- Dual-port SAS SSDs with automatic drive failure detection and rebuild
- Redundant, hot-swappable and customer replaceable hardware components, including SFP+/QSFP+ transceivers, controller and I/O modules, power supplies, and drives
- Automated failover for the data path between the host and the drives with multipathing
- Non-disruptive controller and drive firmware upgrades
- Scale-out clustering
Components and connectors
The following figure shows the front of the ThinkSystem DM7000F controller enclosure.
Figure 2. ThinkSystem DM7000F controller enclosure front view
The front of the ThinkSystem DM7000F controller enclosure includes the LEDs that display the status of the system.
The following figure shows the rear of the ThinkSystem DM7000F 3U controller enclosure.
Figure 3. ThinkSystem DM7000F 3U controller enclosure rear view
The rear of the ThinkSystem DM7000F 3U controller enclosure includes the following components:
- Two redundant hot-swap controllers, each with the following ports:
- Two 10 GbE SFP+ interconnect ports for HA pair and cluster connections.
- Four SFP+ base host ports for 1/10 Gb GbE or 8/16 Gb FC connectivity.
- Two 1/10 GbE RJ-45 base host ports for NAS or iSCSI connectivity.
- Four 12 Gb SAS x4 ports (Mini-SAS HD SFF-8644) for expansion connectivity.
- Two slots for the following optional adapter cards (ports per adapter card):
- Two 10 GbE (NAS or iSCSI) or 4/8/16 Gb FC SFP+ host ports.
- Two 1/10 GbE RJ-45 host ports (NAS or iSCSI).
- Two 10/40 GbE QSFP+ host ports (NAS or iSCSI).
- Two 8/16/32 Gb FC SFP+ host ports (32Gb ports also support NVNe/FC)(SW SFP+ transceivers included).
- Four 4/8/16 Gb FC SFP+ host ports (SW SFP+ transceivers included).
- Four 12 Gb SAS x4 expansion ports (Mini-SAS HD SFF-8644).
- Two 25 GbE iWARP SFP28 host ports (MetroCluster)
- One RJ-45 10/100/1000 Mb Ethernet port for out-of-band management.
- Two serial console ports (RJ-45 and Micro-USB) for another means to configure the system.
- One USB Type A port (for ONTAP software installation or booting)
- Two redundant hot-swap 1460 W (100 - 240 V) AC power supplies (IEC 320-C14 power connector) with integrated cooling fans.
The following figure shows the front of the ThinkSystem DM240S 2U SFF expansion enclosure.
Figure 4. ThinkSystem DM240S expansion enclosure front view
The front of the ThinkSystem DM240S 2U SFF expansion enclosure includes the following components:
- 24 SFF hot-swap drive bays.
- Enclosure status LEDs.
- Enclosure ID LED.
The following figure shows the rear of the ThinkSystem DM240S 2U expansion enclosure.
Figure 5. ThinkSystem DM240S 2U expansion enclosure rear view
The rear of the ThinkSystem DM240S 2U expansion enclosure includes the following components:
- Two redundant hot-swap I/O Modules; each I/O Module provides four 12 Gb SAS x4 expansion ports (Mini-SAS HD SFF-8644) for connections to the controller enclosures and for connecting the expansion enclosures between each other.
- Two redundant hot-swap 913 W (100 - 240 V) AC power supplies (IEC 320-C14 power connector) with integrated cooling fans.
- I/O Module status LEDs.
System specifications
The following table lists the ThinkSystem DM7000F storage system specifications.
Note: The supported hardware options, software features, and interoperability listed in this product guide are based on the ONTAP software version 9.7. For details about specific software releases that introduced support for certain hardware options and software features, refer to the Release notes of the particular software release for the ThinkSystem DM7000F that can be found at:
http://datacentersupport.lenovo.com
Attribute | Specification |
---|---|
Form factor |
|
Controller configuration | Dual active-active controller configuration (HA pair). Up to 6 HA pairs can be combined into a single SAN cluster, or up to 12 HA pairs can be combined into a single NAS cluster. |
HA pair/cluster interconnect ports | 4x 10 GbE SFP+ ports (DAC cables or SW fiber optics [LC]) (2 ports per controller). |
RAID levels | RAID-4, RAID-DP, RAID-TEC. |
Controller memory | 256 GB RAM per system (128 GB per controller). 16 GB battery-backed NVRAM per system (8 GB per controller) mirrored between the controllers. |
Drive bays | Up to 384 SFF hot-swap drive bays (Up to 16 2U24 SFF expansion enclosures). |
Drive technology | 12 Gb SAS SSDs. |
Drive expansion connectivity |
|
Drives | 960 GB, 3.84 TB, 7.68 TB, and 15.36 TB SAS SSDs (1 DWD). |
Storage capacity | Up to 5.89 PB (384x 15.36 TB SFF SSDs). |
Storage protocols |
|
Host connectivity | Base ports (per controller enclosure):
|
MetroCluster | Optional adapter that is used for IP MetroCluster configurations:
|
Host operating systems | Microsoft Windows Server 2012 R2, 2016, and 2019; Red Hat Enterprise Linux (RHEL) 6, 7, and 8; SUSE Linux Enterprise Server (SLES) 11, 12, and 15; VMware vSphere 6.0, 6.5, 6.7, and 7.0. |
Performance* | Up to 350 000 random read IOPS (8 KB blocks). |
Configuration maximums** |
|
Cooling | Redundant cooling with the fans that are built into power supplies. |
Power supply | Two redundant hot-swap 1460 W (100 - 240 V) (DM7000F 3U controller enclosure) or 913 W (100 - 240 V) (DM240S 2U24 enclosure) Platinum AC power supplies. |
Hot-swap parts | Controllers, I/O modules, drives, power supplies, and SFP+/QSFP+ transceivers and DAC cables. |
Management ports |
|
Management interfaces | ThinkSystem Storage Manager web-based GUI; SSH CLI; Serial console CLI; SNMP, email, and syslog alerts; optional Lenovo XClarity. |
Security features | Secure Socket Layer (SSL), Secure Shell (SSH), user level security, role-based access control (RBAC), LDAP authentication. |
Warranty and support | Three-, four-, or five-year customer-replaceable unit and onsite limited warranty with selectable service levels: 9x5 service coverage next business day (NBD) onsite response (Foundation) or 24x7 service coverage with 4-hour onsite response (Essential). Premier Support is also available. Software support is included in the Foundation or Essential Service for the duration of the warranty period. |
Dimensions | Controller enclosure:
|
Weight |
|
* Estimated performance based on internal measurements.
** For a detailed list of configuration limits and restrictions for a specific version of the software, refer to the Lenovo Data Center Support website:
http://datacentersupport.lenovo.com
Controller enclosures
Factory-integrated models of the ThinkSystem DM7000F Unified Flash Storage Array are configured by using the Lenovo Data Center Solution Configurator (DCSC):
http://dcsc.lenovo.com
The following table lists the CTO base models for the ThinkSystem DM7000F.
Description | Machine Type/Model | Feature code |
---|---|---|
Lenovo ThinkSystem DM Series 3U Chassis (2x PSUs, No controller modules) | 7Y40CTO1WW | B38K |
Configuration note: Two DM7000 controllers (feature code B39H) are selected by default in the configurator, and the selection cannot be changed.
The models of the ThinkSystem DM7000F ship with the following items:
- One chassis with the following components:
- Two controllers
- Two power supplies
- Rack Mount Kit
- 2 m USB Cable (USB Type A to Micro-USB)
- Electronic Publications Flyer
- Two customer-configured power cables
Controllers
The ThinkSystem DM7000F controller enclosures ship with two DM7000 controllers. A controller provides interfaces for host connectivity, management, and internal drives, and it runs ONTAP storage management software. Each DM7000 controller enclosure provides 256 GB RAM and 16 GB battery-backed NVRAM (128 GB RAM and 8 GB NVRAM per controller).
The ThinkSystem DM7000F controller enclosures ship with four interconnect 10 GbE SFP+ ports (two ports per controller) to cable a directly-connected dual-controller HA pair or for switched cluster interconnect with multiple dual-controller HA pairs. Up to six HA pairs can be combined into a single SAN cluster or up to 12 HA pairs can be combined into a single NAS cluster.
The ThinkSystem DM7000F controller enclosures ship with eight universal SFP+ ports (four ports per controller) for 1/10 GbE NAS / iSCSI or 4/8/16 Gb FC host connectivity and two 1/10 GbE RJ-45 ports for NAS / iSCSI host connectivity. Each controller also has two expansion slots for optional adapter cards.
Each DM7000F controller enclosure also provides eight integrated 12 Gb SAS x4 expansion ports (Mini-SAS HD SFF-8644 connectors) (four ports per controller) for the attachment of the ThinkSystem DM Series expansion enclosures.
The following interfaces can be added to the ThinkSystem DM7000F controller enclosures with optional adapter cards (ports per adapter card):
- Host interfaces
- 2x 10 GbE or 4/8/16 Gb FC SFP+ ports for NAS, iSCSI, or FC connectivity (for FC connectivity, 16 Gb FC SW SFP+ transceivers [LC connectors] included; for 10 GbE connectivity, optical transceivers or DAC cables should be purchased for the adapter card)
- 2x 1/10 GbE RJ-45 ports for NAS or iSCSI connectivity (require RJ-45 UTP Category 6 cables that should be purchased for the adapter card)
- 2x 10/40 GbE QSFP+ ports for NAS or iSCSI connectivity (require optical transceivers or DAC cables that should be purchased for the adapter card)
- 2x 8/16/32 Gb FC SFP+ ports for FC connectivity, or NVMe/FC with 32 Gb ports (SW SFP+ transceivers with LC connectors included)
- 4x 4/8/16 Gb FC SFP+ ports for FC connectivity (SW SFP+ transceivers with LC connectors included)
- Expansion interfaces: 4x 12 Gb SAS x4 ports (Mini-SAS HD SFF-8644) for expansion connectivity
- MetroCluster interfaces
- 2x 25 GbE iWARP SFP28 ports for IP MetroCluster connectivity (require optical transceivers or DAC cables that should be purchased for the adapter card)
Configuration notes:
- A pair of the universal SFP+ base ports (e0e/0e and e0f/0f or e0g/0g and e0h/0h) in the system must have the same connectivity type (either Ethernet or Fibre Channel, but not both types) and the same type of physical connections; different pairs might have different types of connectivity.
- Both controllers must have matching configurations of the base ports (type and physical connections) and adapter cards (type, quantity, slot location, and physical connections).
- The adapter cards should be installed in pairs: Two or four adapter cards are supported per controller enclosure (two adapter cards per controller), including a combination of the adapter card pairs.
- One 40 GbE port on the dual-port 40 GbE adapter card can be configured as 4x 10 GbE ports (the other 40 GbE port cannot be used in this configuration).
The following table lists the supported host port configurations for the ThinkSystem DM7000F.
Port type and total number of ports per controller enclosure (per controller) | |||||
---|---|---|---|---|---|
10 GbE or 16 Gb FC SFP+ |
10 GbE RJ-45 | 25 GbE SFP28 | 40 GbE QSFP+ | 16 Gb FC SFP+ | 32 Gb FC SFP+ |
Base host ports | |||||
8 (4) | 4 (2) | - | - | - | - |
Base host ports and additional host ports on the optional adapter cards | |||||
8 (4) | 4 (2) | 4 (2) | - | - | - |
8 (4) | 4 (2) | 4 (2) | 4 (2) | - | - |
8 (4) | 4 (2) | 4 (2) | - | 8 (4) | - |
8 (4) | 4 (2) | 4 (2) | - | - | 4 (2) |
8 (4) | 4 (2) | 8 (4) | - | - | - |
8 (4) | 4 (2) | - | 4 (2) | - | - |
8 (4) | 4 (2) | - | 4 (2) | 8 (4) | - |
8 (4) | 4 (2) | - | 4 (2) | - | 4 (2) |
8 (4) | 4 (2) | - | 8 (4) | - | - |
8 (4) | 4 (2) | - | - | 8 (4) | - |
8 (4) | 4 (2) | - | - | 8 (4) | 4 (2) |
8 (4) | 4 (2) | - | - | 16 (8) | - |
8 (4) | 4 (2) | - | - | - | 4 (2) |
8 (4) | 4 (2) | - | - | - | 8 (4) |
8 (4) | 8 (4) | - | - | - | - |
8 (4) | 8 (4) | 4 (2) | - | - | - |
8 (4) | 8 (4) | - | 4 (2) | - | - |
8 (4) | 8 (4) | - | - | 8 (4) | - |
8 (4) | 8 (4) | - | - | - | 4 (2) |
8 (4) | 12 (6) | - | - | - | - |
12 (8) | 4 (2) | - | - | - | - |
12 (8) | 4 (2) | 4 (2) | - | - | - |
12 (8) | 4 (2) | - | 4 (2) | - | - |
12 (8) | 4 (2) | - | - | 8 (4) | - |
12 (8) | 4 (2) | - | - | - | 4 (2) |
12 (8) | 8 (2) | - | - | - | - |
16 (8) | 4 (2) | - | - | - | - |
The following table lists the controller for the DM7000F Storage Array and supported connectivity options.
Description | Part number | Feature code | Maximum quantity per controller enclosure |
---|---|---|---|
Controllers | |||
Lenovo ThinkSystem DM7000 Controller | None* | B39H | 2 |
Adapter cards: Additional host interfaces | |||
Lenovo ThinkSystem DM Series 16Gb FC/10Gb iSCSI 2 port UTA2 Card | 4XC7A14394 | B38S | 4 |
Lenovo ThinkSystem DM Series 10Gb 10GBASE-T 2 port Ethernet Card | 4XC7A14395 | B38T | 4 |
Lenovo ThinkSystem DM Series 25Gb 2 port Ethernet Card (iWARP) | 4XC7A39673 | B7N2 | 4 |
Lenovo ThinkSystem DM Series 40Gb 2 port Ethernet Card | 4XC7A14393 | B38R | 4 |
Lenovo ThinkSystem DM Series 32Gb 2 port Fibre Channel Card | 4XC7A14396 | B38U | 4 |
Lenovo ThinkSystem DM Series 16Gb 4 port Fibre Channel Card | 4XC7A14397 | B38V | 4 |
Adapter cards: Additional expansion interfaces | |||
Lenovo ThinkSystem DM Series 12Gb 4 port SAS Card | 4XC7A14398 | B38W | 4 |
SFP+ options for base ports | |||
1Gb RJ-45 iSCSI SFP+ Module 1 pack | 4XF7A14917 | B4K7 | 8 |
8Gb Fibre Channel SFP+ Module 1 pack | 4XF7A14918 | B4K8 | 8 |
16Gb Fibre Channel SFP+ Module 1 pack | 4XF7A14920 | B4KA | 8 |
SFP+ options for 10 Gb iSCSI / 16 Gb FC adapter card | |||
QLogic 10Gb SFP+ SR Optical Transceiver | 49Y4218 | 0064 | 8 |
SFP+ options for base ports, 10 Gb iSCSI / 16 Gb FC adapter card, and interconnect ports | |||
10Gb SW Optical iSCSI SFP+ Module 1 pack | 4XF7A14919 | B4K9 | 20 |
SFP28 options for 25 GbE adapter card | |||
25Gb Ethernet Optical SFP28 Shortwave Module 1 pack | 4XF7A39597 | B732 | 8 |
QSFP+ options for 40 GbE adapter card | |||
Lenovo 40GBASE-eSR4 QSFP+ Transceiver | 00FE325 | A5U9 | 8 |
OM3 optical cables for 40 GbE QSFP+ eSR4 transceivers | |||
Lenovo 10m QSFP+ MPO-MPO OM3 MMF Cable | 00VX003 | AT2U | 8 |
Lenovo 30m QSFP+ MPO-MPO OM3 MMF Cable | 00VX005 | AT2V | 8 |
OM4 optical cables for 40 GbE QSFP+ eSR4 transceivers | |||
Lenovo 5m MPO-MPO OM4 MMF Cable | 7Z57A03567 | AV25 | 8 |
Lenovo 7m MPO-MPO OM4 MMF Cable | 7Z57A03568 | AV26 | 8 |
Lenovo 10m MPO-MPO OM4 MMF Cable | 7Z57A03569 | AV27 | 8 |
Lenovo 15m MPO-MPO OM4 MMF Cable | 7Z57A03570 | AV28 | 8 |
Lenovo 20m MPO-MPO OM4 MMF Cable | 7Z57A03571 | AV29 | 8 |
Lenovo 30m MPO-MPO OM4 MMF Cable | 7Z57A03572 | AV2A | 8 |
Optical breakout cables for 40 GbE QSFP+ eSR4 transceivers | |||
Lenovo 1m MPO-4xLC OM3 MMF Breakout Cable | 00FM412 | A5UA | 4 |
Lenovo 3m MPO-4xLC OM3 MMF Breakout Cable | 00FM413 | A5UB | 4 |
Lenovo 5m MPO-4xLC OM3 MMF Breakout Cable | 00FM414 | A5UC | 4 |
DAC cable options for 40 GbE QSFP+ host connectivity | |||
Lenovo 1m Passive QSFP+ DAC Cable | 49Y7890 | A1DP | 8 |
Lenovo 3m Passive QSFP+ DAC Cable | 49Y7891 | A1DQ | 8 |
Lenovo 5m Passive QSFP+ DAC Cable | 00D5810 | A2X8 | 8 |
Lenovo 7m Passive QSFP+ DAC Cable | 00D5813 | A2X9 | 8 |
DAC cable options for 40 GbE QSFP+ to 4x 10 GbE SFP+ host connectivity | |||
Lenovo 1m Passive QSFP+ to SFP+ Breakout DAC Cable | 49Y7886 | A1DL | 4 |
Lenovo 3m Passive QSFP+ to SFP+ Breakout DAC Cable | 49Y7887 | A1DM | 4 |
Lenovo 5m Passive QSFP+ to SFP+ Breakout DAC Cable | 49Y7888 | A1DN | 4 |
OM4 cable options for 8/16/32 Gb FC, 10 GbE SW SFP+, and 25 GbE SFP28 optical transceivers | |||
Lenovo 0.5m LC-LC OM4 MMF Cable | 4Z57A10845 | B2P9 | 28 |
Lenovo 1m LC-LC OM4 MMF Cable | 4Z57A10846 | B2PA | 28 |
Lenovo 3m LC-LC OM4 MMF Cable | 4Z57A10847 | B2PB | 28 |
Lenovo 5m LC-LC OM4 MMF Cable | 4Z57A10848 | B2PC | 28 |
Lenovo 10m LC-LC OM4 MMF Cable | 4Z57A10849 | B2PD | 28 |
Lenovo 15m LC-LC OM4 MMF Cable | 4Z57A10850 | B2PE | 28 |
Lenovo 25m LC-LC OM4 MMF Cable | 4Z57A10851 | B2PF | 28 |
Lenovo 30m LC-LC OM4 MMF Cable | 4Z57A10852 | B2PG | 28 |
OM3 cable options for 8/16/32 Gb FC, 10 GbE SW SFP+, and 25 GbE SFP28 optical transceivers | |||
Lenovo 0.5m LC-LC OM3 MMF Cable | 00MN499 | ASR5 | 28 |
Lenovo 1m LC-LC OM3 MMF Cable | 00MN502 | ASR6 | 28 |
Lenovo 3m LC-LC OM3 MMF Cable | 00MN505 | ASR7 | 28 |
Lenovo 5m LC-LC OM3 MMF Cable | 00MN508 | ASR8 | 28 |
Lenovo 10m LC-LC OM3 MMF Cable | 00MN511 | ASR9 | 28 |
Lenovo 15m LC-LC OM3 MMF Cable | 00MN514 | ASRA | 28 |
Lenovo 25m LC-LC OM3 MMF Cable | 00MN517 | ASRB | 28 |
Lenovo 30m LC-LC OM3 MMF Cable | 00MN520 | ASRC | 28 |
DAC cable options for 10 GbE SFP+ connectivity (SFP+ base, adapter card, and interconnect ports) | |||
0.5m Passive DAC SFP+ Cable | 00D6288 | A3RG | 20 |
1m Passive DAC SFP+ Cable | 90Y9427 | A1PH | 20 |
1.5m Passive DAC SFP+ Cable | 00AY764 | A51N | 20 |
2m Passive DAC SFP+ Cable | 00AY765 | A51P | 20 |
3m Passive DAC SFP+ Cable | 90Y9430 | A1PJ | 20 |
5m Passive DAC SFP+ Cable | 90Y9433 | A1PK | 20 |
7m Passive DAC SFP+ Cable | 00D6151 | A3RH | 20 |
DAC cable options for 25 GbE SFP28 connectivity (SFP28 adapter card ports) | |||
Lenovo 1m Passive 25G SFP28 DAC Cable | 7Z57A03557 | AV1W | 8 |
Lenovo 3m Passive 25G SFP28 DAC Cable | 7Z57A03558 | AV1X | 8 |
Lenovo 5m Passive 25G SFP28 DAC Cable | 7Z57A03559 | AV1Y | 8 |
UTP Category 6 cables options for 1/10 GbE RJ-45 host connectivity and 1 GbE RJ-45 management ports | |||
0.75m Green Cat6 Cable | 00WE123 | AVFW | 4 |
1.0m Green Cat6 Cable | 00WE127 | AVFX | 4 |
1.25m Green Cat6 Cable | 00WE131 | AVFY | 4 |
1.5m Green Cat6 Cable | 00WE135 | AVFZ | 4 |
3m Green Cat6 Cable | 00WE139 | AVG0 | 4 |
10m Green Cat6 Cable | 90Y3718 | A1MT | 4 |
25m Green Cat6 Cable | 90Y3727 | A1MW | 4 |
* Factory-installed only.
Expansion enclosures
The ThinkSystem DM7000F supports attachment of up to 16 ThinkSystem DM240S 2U24 SFF expansion enclosures. The expansion enclosures can be added to the system non-disruptively.
The following table lists the CTO base models for the ThinkSystem DM240S 2U24 SFF expansion enclosures.
Description | Machine Type/Model | Feature code |
---|---|---|
Lenovo ThinkSystem Storage 2U24 Chassis (with 2x PSUs) | 7Y58CTO1WW | B38L |
Configuration note: Two I/O expansion modules (feature code B39J) are selected by default in the configurator, and this cannot be changed.
The models of the ThinkSystem DM240S ship with the following items:
- One chassis with the following components:
- Two I/O modules
- Two power supplies
- Rack Mount Kit
- Electronic Publications Flyer
- Two customer-configured power cables
Each ThinkSystem DM Series expansion enclosure ships with two SAS I/O expansion modules. Each I/O expansion module provides four external 12 Gb SAS x4 ports (Mini-SAS HD SFF-8644 connectors labelled Port 1-4) that are used for connections to the ThinkSystem DM7000F and for daisy chaining the expansion enclosures between each other.
The ThinkSystem DM7000F supports up to 16 expansion enclosures in up to six enclosure stacks with up to 4 enclosures in each stack. For one or two stacks, the integrated SAS expansion ports on the DM7000 controller can be used. For three or four stacks, an additional 4-port SAS adapter card is required for the DM7000 controller. For five or six stacks, two additional 4-port SAS adapter cards are required for the DM7000 controller.
The example expansion connectivity topologies for two and four enclosure stacks with dual-path HA (high availability) are shown in the following figures.
Figure 6. DM7000F expansion enclosure connectivity topology: Two stacks
Figure 7. DM7000F expansion enclosure connectivity topology: Four stacks
Expansion cabling rules:
- Ports A and C (integrated and on the SAS adapter card) on the Controller 1 are primary paths to stacks; each port is connected to the Port 1 on the I/O Module A in the first expansion enclosure in a stack.
- Port 3 on the I/O Module A in the first expansion enclosure is connected to Port 1 on the I/O Module A in the adjacent expansion enclosure, and so on (until the last expansion enclosure in a stack is cabled).
- Ports B and D (integrated and on the SAS adapter card) on the Controller 1 are secondary paths to stacks; each port is connected to the Port 3 on the I/O Module B in the last expansion enclosure in a stack.
- Ports A and C (integrated and on the SAS adapter card) on the Controller 2 are primary paths to stacks; each port is connected to the Port 1 on the I/O Module B in the first expansion enclosure in a stack.
- Port 3 on the I/O Module B in the first expansion enclosure is connected to Port 1 on the I/O Module B in the adjacent expansion enclosure, and so on (until the last expansion enclosure in a stack is cabled).
- Ports B and D (integrated and on the SAS adapter card) on the Controller 2 are secondary paths to stacks; each port is connected to the Port 3 on the I/O Module A in the last expansion enclosure in a stack.
The following table lists ordering information for the supported expansion enclosure connectivity options.
Description | Part number | Feature code | Maximum quantity per one expansion enclosure |
---|---|---|---|
External MiniSAS HD 8644/MiniSAS HD 8644 0.5M Cable | 00YL847 | AU16 | 4 |
External MiniSAS HD 8644/MiniSAS HD 8644 1M Cable | 00YL848 | AU17 | 4 |
External MiniSAS HD 8644/MiniSAS HD 8644 2M Cable | 00YL849 | AU18 | 4 |
External MiniSAS HD 8644/MiniSAS HD 8644 3M Cable | 00YL850 | AU19 | 4 |
Configuration note: The following quantities of SAS cables are needed per stack of the expansion enclosures:
- Two SAS cables per expansion enclosure in the stack for connecting the first expansion enclosure in the stack to the controller enclosure and for connections to the adjacent expansion enclosures.
- Two additional SAS cables for connecting the last expansion enclosure in the stack to the controller enclosure.
Drives
The ThinkSystem DM240S 2U24 SFF expansion enclosures support up to 24 SFF hot-swap drives. The following table lists supported drive options for the DM240S 2U24 SFF expansion enclosures.
Description | Part number | Feature code | Maximum quantity per 2U24 enclosure |
---|---|---|---|
2.5-inch 12 Gbps SAS hot-swap SSDs (1 Drive Write per Day) | |||
ThinkSystem 5.76TB (6x 960GB SAS SSDs) 2U24 Drive Pack for DM7000F | 4XB7A16966 | B66H | 4 |
ThinkSystem 23.04TB (6x 3.84TB SAS SSDs) 2U24 Drive Pack for DM7000F | 4XB7A16969 | B66L | 4 |
ThinkSystem 46.08TB (6x 7.68TB SAS SSDs) 2U24 Drive Pack for DM7000F | 4XB7A16972 | B66P | 4 |
ThinkSystem 92.16TB (6x 15.36TB SAS SSDs) 2U24 Drive Pack for DM7000F | 4XB7A16975 | B66S | 4 |
Configuration note: With the DM7000F, the DM240S 2U24 SFF expansion enclosures support from 12 to 24 drives in increments of 6 drives, and all drives in the enclosure must be of the same type and capacity.
Software
In this section:
ONTAP software unifies data management across flash, disk, and cloud to simplify the Lenovo DM storage environment. It builds the foundation for a Data Fabric, making it easy to move the data where it is needed across flash, disk, and cloud resources.
Feature bundles
Controller software for the DM7000F is available in the following bundles of features:
- Unified Base (China only) (Feature B5RH)
- Unified Premium (Feature B5RJ)
The following table summarizes the features in each bundle for the DM7000F.
Feature | Unified Base (PRC only) |
Unified Premium |
---|---|---|
Controller software feature code | B5RH | B5RJ |
RAID-4, RAID-DP, and RAID-TEC data protection | Included | Included |
SAN (Block access): iSCSI, FC, NVMe/FC | Included | Included |
NAS (File access): NFS, CIFS/SMB | Included | Included |
All Flash Array (AFA) capability | Included | Included |
Thin provisioning | Included | Included |
Compression | Included | Included |
Compaction | Included | Included |
Deduplication | Included | Included |
Snapshots | Included | Included |
Encryption* | No | Included* |
Balanced placement | Included | Included |
Dynamic capacity expansion | Included | Included |
Adaptive Quality of Service | Included | Included |
SnapRestore | Included | Included |
FlexClone | Included | Included |
FlexVol | Included | Included |
FlexCache | Included | Included |
SnapMirror asynchronous replication | No | Included |
SyncMirror data protection | Included | Included |
Trusted Platform Module (TPM) support | No | Included |
MetroCluster IP | Included | Included |
NVMe over FC Protocol | No | No |
NVMe over TCP Protocol | Included | Included |
SnapMirror Business Continuity (SMBC) | No | Included |
SnapMirror synchronous replication | No | Included |
FlexGroup | Included | Included |
SnapVault disk-based storage backup | No | Included |
SnapCenter | No | Included |
ONTAP S3 | Included | Included |
ONTAP S3 SnapMirror | No | Optional |
FabricPool object storage tiering | Optional | Optional |
SnapLock data protection | No | Optional |
Security and Compliance Bundle (Anti-ransomware, MTKM, SnapLock) | No | Optional |
Hybrid Cloud Bundle (FabricPool, SnapMirror Cloud) | Optional** | Optional |
* Requires the encryption version of ONTAP. See the ONTAP software section.
** When used with bundles other than Unified Premium, Hybrid Cloud Bundle only adds FabricPool. The use of SnapMirror Cloud requires Unified Premium.
The features are summarized as follows:
- RAID-4, RAID-DP, and RAID-TEC data protection: Provides the flexibility to choose the level of data protection required and helps improve performance and availability with built-in spare capacity and by distributing data across all physical drives in the aggregate, sustaining to up to one (RAID-4), two (RAID-DP), or three (RAID-TEC) concurrent drive failures.
- All Flash Array (AFA) capability: Meets the demand for higher speed, lower latency storage and provides higher IOPS and bandwidth with lower power usage and total cost of ownership than hybrid or HDD-based solutions.
- Thin provisioning: Optimizes efficiency by allocating storage space based on the minimum space required by each application at any given time, so that applications consume only the space they are actually using, not the total space that has been allocated to them, which allows customers to purchase storage they need today and add more as application requirements grow.
- Compression: Provides transparent inline and post-process data compression to reduce the amount of storage that customers need to purchase and manage.
- Compaction: enhances compression to further reduce the amount of storage that customers need to purchase and manage.
- Deduplication: Performs general-purpose deduplication for removal of redundant data to reduce the amount of storage that customers need to purchase and manage.
- Snapshots: Enables creation of read-only copies of data for backup, parallel processing, testing, and development, and have the copies available almost immediately.
- Encryption: Provides software-based encryption for data at rest for enhanced data security with the traditional drives and embedded key management (requires the encryption-capable version of the ONTAP software).
- Balanced placement: Provides automated workload distribution across the cluster to help increase utilization and performance.
- Dynamic capacity expansion: Allows the capacity of a volume or aggregate to be expanded by adding new physical drives.
- Adaptive Quality of Service: Simplifies operations and maintains consistent workload performance by defining QoS policies and automatically adjusting storage resources to respond to workload changes.
- SnapRestore: Enables quick recovery of data by reverting a local volume or file to its previous state from a particular snapshot copy stored on the file system.
- FlexClone: References snapshot metadata to create writable point-in-time copies of a volume.
- FlexVol: Provides abstraction layer between the logical volume and its physical location in the storage array.
- FlexCache: Speeds up access to data and offloads traffic from heavily accessed volumes for read-intensive workloads by placing frequently used data in cache locally or remotely (closer to the point of client access) and serving the data to the clients directly from cache without accessing the data source.
- SnapMirror asynchronous replication: Provides storage system-based data replication between the storage systems containing source (local) and destination (remote) volumes by using asynchronous (at specified regular intervals) data transfers over IP communication links.
- SyncMirror data protection: Adds extra level of data protection and availability by mirroring a pair of RAID aggregates.
- Trusted Platform Module (TPM): For encryption enabled systems. The encryption keys for the onboard key manager (OKM) are no longer stored in the boot device, but instead are stored in the physical TPM for systems so equipped, offering greater security and protection. Moving to the TPM is a nondisruptive process.
- MetroCluster IP: Provides storage system-based clustering with online, real-time data mirroring between the local and remote sites by using synchronous data transfers over IP communication links to deliver continuous availability with zero RPO and near-zero RTO. All storage systems in a MetroCluster IP configuration must be of the same model. New to ONTAP 9.11: MetroCluster with Storage Virtual Machine Disaster Recovery (SVM-DR) can now use a third site for the SVM-DR
- NVMe over TCP Protocol: Enables NVMe over TCP
- Data Protection Optimized (DPO): Increases the amount of concurrent SnapMirror sessions per node, as well as improving SnapMirror performance to the cluster.
- SnapMirror Business Continuity (SMBC): Non-disruptive failover active-active cross site clusters. Based on existing SnapMirror Synchronous Replication. Offers Zero data loss, zero downtime. You do not have to failover the application. If there is a failure the application will continue to run and there will be no need to restart.
- SnapMirror synchronous replication: Provides storage system-based data replication between the storage systems containing source (local) and destination (remote) volumes by using synchronous (as soon as the data is written to the source volume)
- FlexGroup: Enables a single volume to span across multiple clustered storage arrays to maximize storage capacity and automate load distribution. New to ONTAP 9.11: FlexGroups can now be created as SnapLock volumes.
- SnapVault disk-based storage backup: Enables data stored on multiple systems to be backed up to a central, secondary system quickly and efficiently as read-only snapshot copies.
- SnapCenter: Provides application- and virtual machine-aware backup and restoration of data by using the Snapshots technology and leverages the SnapMirror capabilities of storage systems to provide onsite or offsite backup set mirroring for disaster recovery.
- ONTAP S3: Expands the DM Series unified story and allows customers to manage, block, file, and object data from one interface. Customers can now natively store data in S3 buckets onboard the DM Series.
- ONTAP S3 SnapMirror : Enables you to protect buckets in ONTAP S3 object stores using familiar SnapMirror mirroring and backup functionality. Requires ONTAP 9.11 or later on both source and destination clusters. Requires the Unified Premium Bundle.
- SnapMirror Cloud: A backup and recovery technology designed for ONTAP users who want to transition their data protection workflows to the cloud. SnapMirror Cloud is an extension to the family of SnapMirror replication technologies. While SnapMirror is frequently used for ONTAP-to-ONTAP backups, SnapMirror Cloud uses the same replication engine to transfer Snapshot copies for ONTAP to S3-compliant object storage backups.
- Multitenant Key Management (MTKM): Provides the ability for individual tenants or storage virtual machines (SVMs) to maintain their own keys through KMIP for NVE. With multitenant external key management, you can centralize your organization’s key management functions by department or tenant while inherently confirming that keys are not stored near the assets. This approach decreases the possibility of compromise.
- Anti-ransomware: Uses workload analysis in NAS (NFS and SMB) environments to proactively detect and warn about abnormal activity that might indicate a ransomware attack. When an attack is suspected, anti-ransomware also creates new Snapshot backups, in addition to existing protection from scheduled Snapshot copies. New to ONTAP 9.11: Optional multi-admin verification to approve administration functions that could result in data loss.
Add-on feature bundles:
- Security and Compliance Bundle: Licensed per 2-node HA Pair, the Security and Compliance Bundle provides built-in protection from ransomware and while also providing the ability to meet regulatory compliance and organizational data retention requirements.
- Includes: Anti-ransomware feature with Multitenant Key Management (MTKM) and SnapLock
- Hybrid Cloud Bundle: Licensed per TB (3 Year & 5 Year Offerings) the Hybrid Cloud Bundle provides the ability to use S3 SnapMirror from ONTAP to the Public Cloud (AWS S3) and/or SnapMirror Cloud with participating ISV Backup providers.
- Includes SnapMirror Cloud and FabricPool
Optional Extended features also available via Feature on Demand (FoD) (see the Extended ONTAP features section)
- FabricPool: FabricPool is a hybrid storage solution that uses an all flash (all SSD) aggregate as the performance tier and an object store as the external capacity tier. Data in a FabricPool is stored in a tier based on whether it is frequently accessed or not. Using a FabricPool helps you reduce storage cost without compromising performance, efficiency, or protection.
- SnapLock data protection: Creates Write-Once-Read-Many (WORM) non-rewritable, non-erasable data on hard disk drives to prevent files from being altered or deleted until a predetermined or default retention date.
ONTAP software versions
The following table lists the software selection options for the DM7000F. The table also indicates which markets each version is available in.
Feature code |
Description | Availability |
---|---|---|
ONTAP 9.7 | ||
BAYJ | Lenovo ThinkSystem DM Series ONTAP 9.7 SW Base NonEncryption | China only |
BAYL | Lenovo ThinkSystem DM Series ONTAP 9.7 Software Encryption | All markets |
BAYK | Lenovo ThinkSystem DM Series ONTAP 9.7 Software NonEncryption | All markets |
ONTAP 9.8 | ||
BF5S | Lenovo ThinkSystem DM Series ONTAP 9.8 Software Base NonEncryption | China only |
BF5Q | Lenovo ThinkSystem DM Series ONTAP 9.8 Software Encryption | All markets except China |
BF5R | Lenovo ThinkSystem DM Series ONTAP 9.8 Software NonEncryption | All markets |
ONTAP 9.9 | ||
BKF7 | Lenovo ThinkSystem DM Series ONTAP 9.9 Software Base NonEncryption | China only |
BKFB | Lenovo ThinkSystem DM Series ONTAP 9.9 Software Encryption | All markets |
BKFA | Lenovo ThinkSystem DM Series ONTAP 9.9 Software NonEncryption | All markets |
ONTAP 9.10 | ||
BNLY | Lenovo ThinkSystem DM Series ONTAP 9.10 Software Base NonEncryption | China only |
BNM2 | Lenovo ThinkSystem DM Series ONTAP 9.10 Software Encryption | All markets except China |
BNM1 | Lenovo ThinkSystem DM Series ONTAP 9.10 Software NonEncryption | All markets |
ONTAP 9.11 | ||
BRK0 | Lenovo ThinkSystem DM Series ONTAP 9.11 Software Base NonEncryption | China only |
BRJW | Lenovo ThinkSystem DM Series ONTAP 9.11 Software Encryption | All markets except China |
BRJX | Lenovo ThinkSystem DM Series ONTAP 9.11 Software NonEncryption | All markets |
Software maintenance is included in the DM7000F warranty and support (see Warranty and support for details).
Extended ONTAP features
FabricPool and SnapLock WORM data protection are optional extended features. To obtain these feature licenses, order the part numbers as listed in the following table. Upgrades are supported in specific bundles as listed in the Comparison of software features table.
Note: Extended features are only available as field upgrades and are not orderable as part of a CTO configuration.
Part number | Feature code | Description | Quantity |
---|---|---|---|
4P47A16547 | None* | DM Series SnapLock License | 1 per system (contains two licenses) |
4P47A37057 | None* | DM Series FabricPool – 1TB Increment – 3 years | 1 per TB of storage capacity |
4P47A37288 | None* | DM Series FabricPool – 1TB Increment – 5 years | 1 per TB of storage capacity |
4P47A82668 | BPQ6 | Security and Compliance Bundle | 1 per system (contains two licenses) |
4P47A83121 | BQ8X | Hybrid Cloud Bundle 3 year per TB License | 1 per TB of storage capacity |
4P47A83123 | BQ8W | Hybrid Cloud Bundle 5 year per TB License | 1 per TB of storage capacity |
* Field upgrade only; no factory installation.
Configuration notes:
- The SnapLock feature is licensed on a per-controller basis; that is, two licenses are needed per system, and these two licenses are contained in a single orderable part number. These licenses also include 5-year software support entitlement.
- The FabricPool feature is a cluster-wide, capacity-based license that is available for 3-year or 5-year subscription terms.
Ansible playbooks for DM Series
Ansible Playbooks give customers the ability to quickly deploy and use DM Series storage systems using a standard open source deployment tool. Each playbook executes a set of tasks to achieve a configuration/provisioning goal.
Lenovo has created playbooks that can be used with DM Series storage systems to help with:
- Provisioning
- Configuring
To access the Ansible Playbooks for Lenovo ThinkSystem DM Series storage systems, go to the following page:
https://github.com/lenovo/ansible-dm-series-ontap
Management
The ThinkSystem DM7000F supports the following management interfaces:
- Lenovo ThinkSystem Storage Manager, a web-based interface via HTTPS for single-system management or centralized management of the cluster of systems, that runs on the storage system itself and requires only a supported browser (Microsoft Internet Explorer, Google Chrome, or Mozilla Firefox), so there is no need for a separate console or plug-in.
- Command line interface (CLI) via SSH or through serial console.
- Syslog, SNMP, and e-mail notifications.
- Optional Lenovo XClarity for discovery, inventory, monitoring, and alerts.
Power supplies and cables
The ThinkSystem DM7000F 3U controller enclosure ships with two redundant hot-swap 1460 W (100 - 240 V) Platinum AC power supplies, each with an IEC 320-C14 connector.
The ThinkSystem DM240S 2U24 SFF expansion enclosures ship with two redundant hot-swap 913 W (100 - 240 V) Platinum AC power supplies, each with an IEC 320-C14 connector.
Each ThinkSystem DM Series enclosure requires the selection of two power cables.
The following table lists the rack power cable and line cord options that can be ordered for the DM7000F 3U and DM240S 2U24 SFF enclosures (two power cords per enclosure).
Description | Part number | Feature code |
---|---|---|
Rack power cables | ||
1.0m, 10A/100-250V, C13 to IEC 320-C14 Rack Power Cable | 00Y3043 | A4VP |
1.0m, 13A/100-250V, C13 to IEC 320-C14 Rack Power Cable | 4L67A08367 | B0N5 |
1.2m, 16A/100-250V, 2 Short C13s to Short C20 Rack Power Cable | 47C2491 | A3SW |
1.5m, 10A/100-250V, C13 to IEC 320-C14 Rack Power Cable | 39Y7937 | 6201 |
1.5m, 13A/100-250V, C13 to IEC 320-C14 Rack Power Cable | 4L67A08368 | B0N6 |
2.0m, 10A/100-250V, C13 to IEC 320-C14 Rack Power Cable | 4L67A08365 | B0N4 |
2.0m, 13A/125V-10A/250V, C13 to IEC 320-C14 Rack Power Cable | 4L67A08369 | 6570 |
2.5m, 16A/100-250V, 2 Long C13s to Short C20 Rack Power Cable | 47C2492 | A3SX |
2.8m, 10A/100-250V, C13 to IEC 320-C14 Rack Power Cable | 4L67A08366 | 6311 |
2.8m, 13A/125V-10A/250V, C13 to IEC 320-C14 Rack Power Cable | 4L67A08370 | 6400 |
2.8m, 10A/100-250V, C13 to IEC 320-C20 Rack Power Cable | 39Y7938 | 6204 |
2.8m, 16A/100-250V, 2 Short C13s to Long C20 Rack Power Cable | 47C2493 | A3SY |
4.1m, 16A/100-250V, 2 Long C13s to Long C20 Rack Power Cable | 47C2494 | A3SZ |
4.3m, 10A/100-250V, C13 to IEC 320-C14 Rack Power Cable | 39Y7932 | 6263 |
4.3m, 13A/125V-10A/250V, C13 to IEC 320-C14 Rack Power Cable | 4L67A08371 | 6583 |
Line cords | ||
Argentina 2.8m, 10A/250V, C13 to IRAM 2073 Line Cord | 39Y7930 | 6222 |
Argentina 4.3m, 10A/250V, C13 to IRAM 2073 Line Cord | 81Y2384 | 6492 |
Australia/New Zealand 2.8m, 10A/250V, C13 to AS/NZS 3112 Line Cord | 39Y7924 | 6211 |
Australia/New Zealand 4.3m, 10A/250V, C13 to AS/NZS 3112 Line Cord | 81Y2383 | 6574 |
Brazil 2.8m, 10A/250V, C13 to NBR 14136 Line Cord | 69Y1988 | 6532 |
Brazil 4.3m, 10A/250V, C13 to NBR14136 Line Cord | 81Y2387 | 6404 |
China 2.8m, 10A/250V, C13 to GB 2099.1 Line Cord | 39Y7928 | 6210 |
China 4.3m, 10A/250V, C13 to GB 2099.1 Line Cord | 81Y2378 | 6580 |
Denmark 2.8m, 10A/250V, C13 to DK2-5a Line Cord | 39Y7918 | 6213 |
Denmark 4.3m, 10A/250V, C13 to DK2-5a Line Cord | 81Y2382 | 6575 |
Europe 2.8m, 10A/250V, C13 to CEE7-VII Line Cord | 39Y7917 | 6212 |
Europe 4.3m, 10A/250V, C13 to CEE7-VII Line Cord | 81Y2376 | 6572 |
India 2.8m, 10A/250V, C13 to IS 6538 Line Cord | 39Y7927 | 6269 |
India 4.3m, 10A/250V, C13 to IS 6538 Line Cord | 81Y2386 | 6567 |
Israel 2.8m, 10A/250V, C13 to SI 32 Line Cord | 39Y7920 | 6218 |
Israel 4.3m, 10A/250V, C13 to SI 32 Line Cord | 81Y2381 | 6579 |
Italy 2.8m, 10A/250V, C13 to CEI 23-16 Line Cord | 39Y7921 | 6217 |
Italy 4.3m, 10A/250V, C13 to CEI 23-16 Line Cord | 81Y2380 | 6493 |
Japan 2.8m, 12A/125V, C13 to JIS C-8303 Line cord | 46M2593 | A1RE |
Japan 2.8m, 12A/250V, C13 to JIS C-8303 Line Cord | 4L67A08357 | 6533 |
Japan 4.3m, 12A/125V, C13 to JIS C-8303 Line Cord | 39Y7926 | 6335 |
Japan 4.3m, 12A/250V, C13 to JIS C-8303 Line Cord | 4L67A08362 | 6495 |
Korea 2.8m, 12A/250V, C13 to KS C8305 Line Cord | 39Y7925 | 6219 |
Korea 4.3m, 12A/250V, C13 to KS C8305 Line Cord | 81Y2385 | 6494 |
South Africa 2.8m, 10A/250V, C13 to SABS 164 Line Cord | 39Y7922 | 6214 |
South Africa 4.3m, 10A/250V, C13 to SABS 164 Line Cord | 81Y2379 | 6576 |
Switzerland 2.8m, 10A/250V, C13 to SEV 1011-S24507 Line Cord | 39Y7919 | 6216 |
Switzerland 4.3m, 10A/250V, C13 to SEV 1011-S24507 Line Cord | 81Y2390 | 6578 |
Taiwan 2.8m, 10A/125V, C13 to CNS 10917-3 Line Cord | 23R7158 | 6386 |
Taiwan 2.8m, 10A/250V, C13 to CNS 10917-3 Line Cord | 81Y2375 | 6317 |
Taiwan 2.8m, 15A/125V, C13 to CNS 10917-3 Line Cord | 81Y2374 | 6402 |
Taiwan 4.3m, 10A/125V, C13 to CNS 10917-3 Line Cord | 4L67A08363 | AX8B |
Taiwan 4.3m, 10A/250V, C13 to CNS 10917-3 Line Cord | 81Y2389 | 6531 |
Taiwan 4.3m, 15A/125V, C13 to CNS 10917-3 Line Cord | 81Y2388 | 6530 |
United Kingdom 2.8m, 10A/250V, C13 to BS 1363/A Line Cord | 39Y7923 | 6215 |
United Kingdom 4.3m, 10A/250V, C13 to BS 1363/A Line Cord | 81Y2377 | 6577 |
United States 2.8m, 10A/125V, C13 to NEMA 5-15P Line Cord | 90Y3016 | 6313 |
United States 2.8m, 10A/250V, C13 to NEMA 6-15P Line Cord | 46M2592 | A1RF |
United States 2.8m, 13A/125V, C13 to NEMA 5-15P Line Cord | 00WH545 | 6401 |
United States 4.3m, 10A/125V, C13 to NEMA 5-15P Line Cord | 4L67A08359 | 6370 |
United States 4.3m, 10A/250V, C13 to NEMA 6-15P Line Cord | 4L67A08361 | 6373 |
United States 4.3m, 13A/125V, C13 to NEMA 5-15P Line Cord | 4L67A08360 | AX8A |
Rack installation
The individually shipped ThinkSystem DM7000F and DM240S enclosures come with the ThinkSystem Storage Rack Mount Kit 2U24/4U60 listed in the following table.
Description | Feature code | Quantity |
---|---|---|
Lenovo ThinkSystem Storage Rack Mount Kit 2U24/4U60 | B38Y | 1 |
When the ThinkSystem DM Series enclosures are factory-integrated and shipped installed in a rack cabinet, the rack mount kits that support Ship-in-Rack (SIR) capabilities are derived by the configurator.
The SIR-capable rack mount kits are listed in the following table.
Description | Feature code | Quantity |
---|---|---|
Lenovo ThinkSystem Storage Rack Mount Kit 2U12 | B38X | 1 |
Lenovo ThinkSystem Storage SIR Rack Mount Kit (for 2U24 enclosures) | B6TH | 1 |
DM 3U Adjustable Rail Kit (SIR) | B79Z | 1 |
DM/DE 4U Adjustable Rail Kit (SIR) | B742 | 1 |
The following table summarizes the rack mount kit features and specifications.
Attribute | Screw-in fixed rail with adjustable depth | ||
---|---|---|---|
2U24/4U60 | 2U24 SIR | 3U SIR | |
Feature code | B38Y | B6TH | B79Z |
Enclosure support | DM7000F, DM240S | DM240S | DM7000F |
Rail type | Fixed (static) with adjustable depth | Fixed (static) with adjustable depth | Fixed (static) with adjustable depth |
Tool-less installation | No | No | No |
In-rack maintenance | Yes* | Yes* | Yes* |
Ship-in-rack (SIR) support | No | Yes | Yes |
1U PDU support | Yes | Yes | Yes |
0U PDU support | Limited** | Limited** | Limited** |
Rack type | IBM or Lenovo 4-post, IEC standard-compliant | IBM or Lenovo 4-post, IEC standard-compliant | IBM or Lenovo 4-post, IEC standard-compliant |
Mounting holes | Square or round | Square or round | Square or round |
Mounting flange thickness | 2 mm (0.08 in.) – 3.3 mm (0.13 in.) |
2 mm (0.08 in.) – 3.3 mm (0.13 in.) |
2 mm (0.08 in.) – 3.3 mm (0.13 in.) |
Distance between front and rear mounting flanges^ | 605 mm (23.8 in.) – 812.8 mm (32 in.) |
605 mm (23.8 in.) – 812.8 mm (32 in.) |
605 mm (23.8 in.) – 812.8 mm (32 in.) |
* The majority of the enclosure components can be serviced from the front or rear of the enclosure, which does not require the removal of the enclosure from the rack cabinet.
** If a 0U PDU is used, the rack cabinet must be at least 1000 mm (39.37 in.) deep for 2U24 and 3U enclosures.
^ Measured when mounted on the rack, from the front surface of the front mounting flange to the rear most point of the rail.
Physical specifications
The ThinkSystem DM7000F controller enclosure has the following dimensions and weight (approximate):
- Height: 130 mm (5.1 in.)
- Width: 447 mm (17.6 in.)
- Depth: 608 mm (23.9 in.)
- Weight (fully configured): 34.5 kg (76.1 lb)
The ThinkSystem DM240S 2U24 SFF enclosures have the following dimensions and weight (approximate):
- Height: 85 mm (3.4 in.)
- Width: 449 mm (17.7 in.)
- Depth: 484 mm (19.1 in.)
- Weight (fully configured): 24.4 kg (53.8 lb)
Operating environment
The ThinkSystem DM7000F and DM240S 2U24 SFF enclosures are supported in the following environment:
- Air temperature:
- Operating: 5 °C - 45 °C (41 °F - 113 °F)
- Non-operating: -40 °C - +70 °C (-40 °F - 158 °F)
- Maximum altitude: 3050 m (10,000 ft)
- Relative humidity:
- Operating: 8% - 90% (non-condensing)
- Non-operating: 10% - 95% (non-condensing)
- Electrical power:
- DM7000F
- 100 to 127 (nominal) V AC; 50 Hz or 60 Hz; 6.69 A
- 200 to 240 (nominal) V AC; 50 Hz or 60 Hz; 3.35 A
- Maximum system power load: 636 W
- DM240S 2U24 SFF
- 100 to 127 (nominal) V AC; 50 Hz or 60 Hz; 4.11 A
- 200 to 240 (nominal) V AC; 50 Hz or 60 Hz; 2.05 A
- Maximum system power load: 390 W
- DM7000F
- Heat dissipation:
- DM7000F: 2170 BTU/hour
- DM240S 2U24 SFF: 1331 BTU/hour
- Acoustical noise emission:
- DM7000F: 7.8 bels
- DM240S 2U24 SFF: 6.9 bels
Warranty upgrades and post-warranty support
The DM7000F has a 1-year warranty and the expansion enclosure has a 1-year or 3-year warranty based on the machine type of the system, as listed in the following table.
System | Machine type 1 year warranty |
Machine type 3 year warranty |
---|---|---|
DM7000F Controller Enclosure | 7Y40 | - |
DM240S 2U24 SFF Expansion Enclosure | 7Y58 | 7D7Y |
Our global network of regional support centers offers consistent, local-language support enabling you to vary response times and level of service to match the criticality of your support needs:
- Standard Next Business Day – Best choice for non-essential systems requiring simple maintenance.
- Premier Next Business Day – Best choice for essential systems requiring technical expertise from senior-level Lenovo engineers.
- Premier 24x7 4-Hour Response – Best choice for systems where maximum uptime is critical.
- Premier Enhanced Storage Support 24x7 4-Hour Response – Best choice for storage systems where maximum uptime is critical.
For more information, consult the brochure Lenovo Operational Support Services for Data Centers Services.
Services
Lenovo Services is a dedicated partner to customer success. Lenovo's goal for customers is to reduce capital outlays, mitigate IT risks, and accelerate time to productivity.
Here is a more in-depth look at what Lenovo can do for their customers:
- Asset Recovery Services
Asset Recovery Services (ARS) helps customers recover the maximum value from their end-of-life equipment in a cost-effective and secure way. On top of simplifying the transition from old to new equipment, ARS mitigates environmental and data security risks associated with data center equipment disposal. Lenovo ARS is a cash-back solution for equipment based on its remaining market value, yielding maximum value from aging assets and lowering total cost of ownership for customers.
- Assessment Services
An assessment helps solve customer IT challenges through an onsite, multi-day session with a Lenovo technology expert. Lenovo performs a tools-based assessment which provides a comprehensive and thorough review of a company's environment and technology systems. In addition to the technology-based functional requirements, the consultant also discusses and records the non-functional business requirements, challenges, and constraints. Assessments help organizations, no matter how large or small, get a better return on their IT investment and overcome challenges in the ever-changing technology landscape.
- Design Services
Professional Services consultants perform infrastructure design and implementation planning to support customer's strategy. The high-level architectures provided by the assessment service are turned into low level designs and wiring diagrams, which are reviewed and approved prior to implementation. The implementation plan will demonstrate an outcome-based proposal to provide business capabilities through infrastructure with a risk-mitigated project plan.
- Basic Hardware Installation
Lenovo experts can seamlessly manage the physical installation of customer's server, storage, or networking hardware. Working at a time convenient for the customer (business hours or off shift), the technician will unpack and inspect the systems on customer site, install options, mount in a rack cabinet, connect to power and network, check and update firmware to the latest levels, verify operation, and dispose of the packaging, allowing customers to focus on other priorities.
- Deployment Services
When investing in new IT infrastructures, customers need to ensure that their business will see quick time to value with little to no disruption. Lenovo deployments are designed by development and engineering teams who know Lenovo products and solutions better than anyone else, and Lenovo technicians own the process from delivery to completion. Lenovo will conduct remote preparation and planning, configure and integrate systems, validate systems, verify and update appliance firmware, train on administrative tasks, and provide post-deployment documentation. Customer’s IT teams leverage Lenovo skills to enable IT staff to transform with higher level roles and tasks.
- Integration, Migration, and Expansion Services
Integration, Migration, and Expansion Services allow to move existing physical and virtual workloads easily, or to determine technical requirements to support increased workloads while maximizing performance. These services include tuning, validation, and documenting ongoing run processes, and they leverage migration assessment planning documents to perform necessary migrations.
Some service options may not be available in every region. For more information about Lenovo service offerings that are available in a specific region, contact a local Lenovo sales representative or business partner.
Lenovo TruScale
Lenovo TruScale XaaS is your set of flexible IT services that makes everything easier. Streamline IT procurement, simplify infrastructure and device management, and pay only for what you use – so your business is free to grow and go anywhere.
Lenovo TruScale is the unified solution that gives you simplified access to:
- The industry’s broadest portfolio – from pocket to cloud – all delivered as a service
- A single-contract framework for full visibility and accountability
- The global scale to rapidly and securely build teams from anywhere
- Flexible fixed and metered pay-as-you-go models with minimal upfront cost
- The growth-driving combination of hardware, software, infrastructure, and solutions – all from one single provider with one point of accountability.
For information about Lenovo TruScale offerings that are available in your region, contact your local Lenovo sales representative or business partner.
Regulatory compliance
The ThinkSystem DM Series enclosures conform to the following regulations:
- United States: FCC Part 15, Class A; UL 60950-1
- Canada: ICES-003, Class A; CAN/CSA-C22.2 60950-1
- Mexico NOM
- European Union: CE Mark (EN55032 Class A, EN55024, IEC/EN60950-1); ROHS Directive 2011/65/EU
- Russia, Kazakhstan, Belarus: EAC
- China: CCC GB 4943.1, GB 17625.1, GB 9254 Class A; CELP; CECP
- Japan: VCCI, Class A
- Taiwan: BSMI CNS 13438, Class A; CNS 14336-1
- Korea KN32/35, Class A
- Australia/New Zealand: AS/NZS CISPR 22 Class A
Interoperability
Lenovo provides end-to-end storage compatibility testing to deliver interoperability throughout the network. The ThinkSystem DM7000F Unified Flash Storage Array supports attachment to Lenovo servers by using NVMe over Fibre Channel (NVMe/FC), NAS (NFS and CIFS/SMB), iSCSI, and Fibre Channel storage connectivity protocols.
For end-to-end storage configuration support, refer to the Lenovo Storage Interoperation Center (LSIC):
https://datacentersupport.lenovo.com/us/en/lsic
Use the LSIC to select the known components of your configuration and then get a list all other supported combinations, with details about supported hardware, firmware, operating systems, and drivers, plus any additional configuration notes. View results on screen or export them to Excel.
Cluster interconnect
The following table lists the Ethernet storage switch that can be used with the ThinkSystem DM7000F Unified Hybrid Storage Array for cluster interconnect and MetroCluster IP configurations.
Description | Part number |
---|---|
BES-53248 Ethernet Storage Switch: 16x SFP ports and 2x QSFP ports active, 2 PS (CTO only) | 7D2SCTO1WW |
For more information, see the BES-53248 Ethernet Storage Switch for Lenovo Product Guide:
http://lenovopress.com/lp1226
Fibre Channel SAN switches
Lenovo offers the ThinkSystem DB Series of Fibre Channel SAN switches for high-performance storage expansion. See the DB Series product guides for models and configuration options:
- ThinkSystem DB Series SAN Switches:
https://lenovopress.com/storage/switches/rack#rt=product-guide
Rack cabinets
The following table lists the supported rack cabinets.
Model | Description |
---|---|
7D6DA007WW | ThinkSystem 42U Onyx Primary Heavy Duty Rack Cabinet (1200mm) |
7D6DA008WW | ThinkSystem 42U Pearl Primary Heavy Duty Rack Cabinet (1200mm) |
7D6EA009WW | ThinkSystem 48U Onyx Primary Heavy Duty Rack Cabinet (1200mm) |
7D6EA00AWW | ThinkSystem 48U Pearl Primary Heavy Duty Rack Cabinet (1200mm) |
93604PX | 42U 1200mm Deep Dynamic Rack |
93604EX | 42U 1200mm Deep Dynamic Expansion Rack |
93614PX | 42U 1200mm Deep Static Rack |
93614EX | 42U 1200mm Deep Static Expansion Rack |
93634PX | 42U 1100mm Dynamic Rack |
93634EX | 42U 1100mm Dynamic Expansion Rack |
93074RX | 42U Standard Rack (1000mm) |
93084PX | 42U Enterprise Rack |
93084EX | 42U Enterprise Expansion Rack |
For specifications about these racks, see the Lenovo Rack Cabinet Reference, available from:
https://lenovopress.com/lp1287-lenovo-rack-cabinet-reference
For more information, see the list of Product Guides in the Rack cabinets category:
https://lenovopress.com/servers/options/racks
Power distribution units
The following table lists the power distribution units (PDUs) that are offered by Lenovo.
Part number |
Feature code |
Description |
ANZ
|
ASEAN
|
Brazil
|
EET
|
MEA
|
RUCIS
|
WE
|
HTK
|
INDIA
|
JAPAN
|
LA
|
NA
|
PRC
|
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
0U Basic PDUs | |||||||||||||||
4PU7A93176 | C0QH | 0U 36 C13 and 6 C19 Basic 32A 1 Phase PDU v2 | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
4PU7A93169 | C0DA | 0U 36 C13 and 6 C19 Basic 32A 1 Phase PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
4PU7A93177 | C0QJ | 0U 24 C13/C15 and 24 C13/C15/C19 Basic 32A 3 Phase WYE PDU v2 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
4PU7A93170 | C0D9 | 0U 24 C13/C15 and 24 C13/C15/C19 Basic 32A 3 Phase WYE PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
00YJ776 | ATZY | 0U 36 C13/6 C19 24A 1 Phase PDU | N | Y | Y | N | N | N | N | N | N | Y | Y | Y | N |
00YJ779 | ATZX | 0U 21 C13/12 C19 48A 3 Phase PDU | N | N | Y | N | N | N | Y | N | N | Y | Y | Y | N |
00YJ777 | ATZZ | 0U 36 C13/6 C19 32A 1 Phase PDU | Y | Y | N | Y | Y | Y | Y | Y | Y | N | N | Y | Y |
00YJ778 | AU00 | 0U 21 C13/12 C19 32A 3 Phase PDU | Y | Y | N | Y | Y | Y | Y | Y | Y | N | N | Y | Y |
0U Switched and Monitored PDUs | |||||||||||||||
4PU7A93181 | C0QN | 0U 21 C13/C15 and 21 C13/C15/C19 Switched and Monitored 48A 3 Phase Delta PDU v2 (60A derated) | N | Y | N | N | N | N | N | Y | N | Y | N | Y | N |
4PU7A93174 | C0D5 | 0U 21 C13/C15 and 21 C13/C15/C19 Switched and Monitored 48A 3 Phase Delta PDU (60A derated) | N | Y | N | Y | N | N | Y | Y | N | N | N | Y | N |
4PU7A93178 | C0QK | 0U 20 C13 and 4 C19 Switched and Monitored 32A 1 Phase PDU v2 | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
4PU7A93171 | C0D8 | 0U 20 C13 and 4 C19 Switched and Monitored 32A 1 Phase PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
4PU7A93182 | C0QP | 0U 18 C13/C15 and 18 C13/C15/C19 Switched and Monitored 63A 3 Phase WYE PDU v2 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
4PU7A93175 | C0CS | 0U 18 C13/C15 and 18 C13/C15/C19 Switched and Monitored 63A 3 Phase WYE PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
4PU7A93180 | C0QM | 0U 18 C13/C15 and 18 C13/C15/C19 Switched and Monitored 32A 3 Phase WYE PDU v2 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
4PU7A93173 | C0D6 | 0U 18 C13/C15 and 18 C13/C15/C19 Switched and Monitored 32A 3 Phase WYE PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
4PU7A93179 | C0QL | 0U 16 C13/C15 and 16 C13/C15/C19 Switched and Monitored 24A 1 Phase PDU v2 (30A derated) | N | Y | N | N | N | N | N | Y | N | Y | N | Y | N |
4PU7A93172 | C0D7 | 0U 16 C13/C15 and 16 C13/C15/C19 Switched and Monitored 24A 1 Phase PDU(30A derated) | N | Y | N | Y | N | N | Y | Y | N | N | N | Y | N |
00YJ783 | AU04 | 0U 12 C13/12 C19 Switched and Monitored 48A 3 Phase PDU | N | N | Y | N | N | N | Y | N | N | Y | Y | Y | N |
00YJ781 | AU03 | 0U 20 C13/4 C19 Switched and Monitored 24A 1 Phase PDU | N | N | Y | N | Y | N | Y | N | N | Y | Y | Y | N |
00YJ782 | AU02 | 0U 18 C13/6 C19 Switched and Monitored 32A 3 Phase PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | N | Y |
00YJ780 | AU01 | 0U 20 C13/4 C19 Switched and Monitored 32A 1 Phase PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | N | Y |
1U Switched and Monitored PDUs | |||||||||||||||
4PU7A90808 | C0D4 | 1U 18 C19/C13 Switched and monitored 48A 3P WYE PDU V2 ETL | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
4PU7A81117 | BNDV | 1U 18 C19/C13 switched and monitored 48A 3P WYE PDU - ETL | N | N | N | N | N | N | N | N | N | N | N | Y | N |
4PU7A90809 | C0DE | 1U 18 C19/C13 Switched and monitored 48A 3P WYE PDU V2 CE | N | N | N | N | N | Y | Y | N | N | N | N | N | N |
4PU7A81118 | BNDW | 1U 18 C19/C13 switched and monitored 48A 3P WYE PDU - CE | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | N | Y |
4PU7A90810 | C0DD | 1U 18 C19/C13 Switched and monitored 80A 3P Delta PDU V2 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
4PU7A77467 | BLC4 | 1U 18 C19/C13 Switched and Monitored 80A 3P Delta PDU | N | N | N | N | N | N | N | N | N | Y | N | Y | N |
4PU7A90811 | C0DC | 1U 12 C19/C13 Switched and monitored 32A 3P WYE PDU V2 | N | N | N | N | N | Y | Y | N | N | N | N | N | N |
4PU7A77468 | BLC5 | 1U 12 C19/C13 switched and monitored 32A 3P WYE PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
4PU7A90812 | C0DB | 1U 12 C19/C13 Switched and monitored 60A 3P Delta PDU V2 | N | N | N | N | N | N | N | N | N | Y | N | N | N |
4PU7A77469 | BLC6 | 1U 12 C19/C13 switched and monitored 60A 3P Delta PDU | N | N | N | N | N | N | N | N | N | N | N | Y | N |
46M4002 | 5896 | 1U 9 C19/3 C13 Switched and Monitored DPI PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
46M4004 | 5894 | 1U 12 C13 Switched and Monitored DPI PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
46M4003 | 5897 | 1U 9 C19/3 C13 Switched and Monitored 60A 3 Phase PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
46M4005 | 5895 | 1U 12 C13 Switched and Monitored 60A 3 Phase PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
1U Ultra Density Enterprise PDUs (9x IEC 320 C13 + 3x IEC 320 C19 outlets) | |||||||||||||||
71763NU | 6051 | Ultra Density Enterprise C19/C13 PDU 60A/208V/3PH | N | N | Y | N | N | N | N | N | N | Y | Y | Y | N |
71762NX | 6091 | Ultra Density Enterprise C19/C13 PDU Module | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
1U C13 Enterprise PDUs (12x IEC 320 C13 outlets) | |||||||||||||||
39M2816 | 6030 | DPI C13 Enterprise PDU Plus Module (WW) | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
39Y8941 | 6010 | DPI C13 Enterprise PDU Module (WW) | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
1U C19 Enterprise PDUs (6x IEC 320 C19 outlets) | |||||||||||||||
39Y8948 | 6060 | DPI C19 Enterprise PDU Module (WW) | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
39Y8923 | 6061 | DPI Three-phase 60A/208V C19 Enterprise PDU (US) | N | N | Y | N | N | N | Y | N | N | N | Y | Y | N |
1U Front-end PDUs (3x IEC 320 C19 outlets) | |||||||||||||||
39Y8938 | 6002 | DPI Single-phase 30A/120V Front-end PDU (US) | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
39Y8939 | 6003 | DPI Single-phase 30A/208V Front-end PDU (US) | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
39Y8934 | 6005 | DPI Single-phase 32A/230V Front-end PDU (International) | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
39Y8940 | 6004 | DPI Single-phase 60A/208V Front-end PDU (US) | Y | N | Y | Y | Y | Y | Y | N | N | Y | Y | Y | N |
39Y8935 | 6006 | DPI Single-phase 63A/230V Front-end PDU (International) | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
1U NEMA PDUs (6x NEMA 5-15R outlets) | |||||||||||||||
39Y8905 | 5900 | DPI 100-127V NEMA PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Line cords for 1U PDUs that ship without a line cord | |||||||||||||||
40K9611 | 6504 | 4.3m, 32A/380-415V, EPDU/IEC 309 3P+N+G 3ph wye (non-US) Line Cord | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
40K9612 | 6502 | 4.3m, 32A/230V, EPDU to IEC 309 P+N+G (non-US) Line Cord | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
40K9613 | 6503 | 4.3m, 63A/230V, EPDU to IEC 309 P+N+G (non-US) Line Cord | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
40K9614 | 6500 | 4.3m, 30A/208V, EPDU to NEMA L6-30P (US) Line Cord | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
40K9615 | 6501 | 4.3m, 60A/208V, EPDU to IEC 309 2P+G (US) Line Cord | N | N | Y | N | N | N | Y | N | N | Y | Y | Y | N |
40K9617 | 6505 | 4.3m, 32A/230V, Souriau UTG Female to AS/NZ 3112 (Aus/NZ) Line Cord | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
40K9618 | 6506 | 4.3m, 32A/250V, Souriau UTG Female to KSC 8305 (S. Korea) Line Cord | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
For more information, see the Lenovo Press documents in the PDU category:
https://lenovopress.com/servers/options/pdu
Uninterruptible power supply units
The following table lists the uninterruptible power supply (UPS) units that are offered by Lenovo.
Part number | Description |
---|---|
Rack-mounted or tower UPS units - 100-125VAC | |
7DD5A001WW | RT1.5kVA 2U Rack or Tower UPS-G2 (100-125VAC) |
55941AX | RT1.5kVA 2U Rack or Tower UPS (100-125VAC) |
55942AX | RT2.2kVA 2U Rack or Tower UPS (100-125VAC) |
7DD5A003WW | RT3kVA 2U Rack or Tower UPS-G2 (100-125VAC) |
55943AX | RT3kVA 2U Rack or Tower UPS (100-125VAC) |
Rack-mounted or tower UPS units - 200-240VAC | |
7DD5A002WW | RT1.5kVA 2U Rack or Tower UPS-G2 (200-240VAC) |
55941KX | RT1.5kVA 2U Rack or Tower UPS (200-240VAC) |
55942KX | RT2.2kVA 2U Rack or Tower UPS (200-240VAC) |
7DD5A005WW | RT3kVA 2U Rack or Tower UPS-G2 (200-240VAC) |
55943KX | RT3kVA 2U Rack or Tower UPS (200-240VAC) |
7DD5A007WW | RT5kVA 3U Rack or Tower UPS-G2 (200-240VAC) |
55945KX | RT5kVA 3U Rack or Tower UPS (200-240VAC) |
7DD5A008WW | RT6kVA 3U Rack or Tower UPS-G2 (200-240VAC) |
55946KX | RT6kVA 3U Rack or Tower UPS (200-240VAC) |
55948KX | RT8kVA 6U Rack or Tower UPS (200-240VAC) |
7DD5A00AWW | RT11kVA 6U Rack or Tower UPS-G2 (200-240VAC) |
55949KX | RT11kVA 6U Rack or Tower UPS (200-240VAC) |
55943KT† | ThinkSystem RT3kVA 2U Standard UPS (200-230VAC) (2x C13 10A, 2x GB 10A, 1x C19 16A outlets) |
55943LT† | ThinkSystem RT3kVA 2U Long Backup UPS (200-230VAC) (2x C13 10A, 2x GB 10A, 1x C19 16A outlets) |
55946KT† | ThinkSystem RT6kVA 5U UPS (200-230VAC) (2x C13 10A outlets, 1x Terminal Block output) |
5594XKT† | ThinkSystem RT10kVA 5U UPS (200-230VAC) (2x C13 10A outlets, 1x Terminal Block output) |
Rack-mounted or tower UPS units - 380-415VAC | |
55948PX | RT8kVA 6U 3:1 Phase Rack or Tower UPS (380-415VAC) |
55949PX | RT11kVA 6U 3:1 Phase Rack or Tower UPS (380-415VAC) |
† Only available in China and the Asia Pacific market.
For more information, see the list of Product Guides in the UPS category:
https://lenovopress.com/servers/options/ups
Lenovo Financial Services
Why wait to obtain the technology you need now? No payments for 90 days and predictable, low monthly payments make it easy to budget for your Lenovo solution.
- Flexible
Our in-depth knowledge of the products, services and various market segments allows us to offer greater flexibility in structures, documentation and end of lease options.
- 100% Solution Financing
Financing your entire solution including hardware, software, and services, ensures more predictability in your project planning with fixed, manageable payments and low monthly payments.
- Device as a Service (DaaS)
Leverage latest technology to advance your business. Customized solutions aligned to your needs. Flexibility to add equipment to support growth. Protect your technology with Lenovo's Premier Support service.
- 24/7 Asset management
Manage your financed solutions with electronic access to your lease documents, payment histories, invoices and asset information.
- Fair Market Value (FMV) and $1 Purchase Option Leases
Maximize your purchasing power with our lowest cost option. An FMV lease offers lower monthly payments than loans or lease-to-own financing. Think of an FMV lease as a rental. You have the flexibility at the end of the lease term to return the equipment, continue leasing it, or purchase it for the fair market value. In a $1 Out Purchase Option lease, you own the equipment. It is a good option when you are confident you will use the equipment for an extended period beyond the finance term. Both lease types have merits depending on your needs. We can help you determine which option will best meet your technological and budgetary goals.
Ask your Lenovo Financial Services representative about this promotion and how to submit a credit application. For the majority of credit applicants, we have enough information to deliver an instant decision and send a notification within minutes.
Related product families
Product families related to this document are the following:
Trademarks
Lenovo and the Lenovo logo are trademarks or registered trademarks of Lenovo in the United States, other countries, or both. A current list of Lenovo trademarks is available on the Web at https://www.lenovo.com/us/en/legal/copytrade/.
The following terms are trademarks of Lenovo in the United States, other countries, or both:
Lenovo®
ThinkSystem®
XClarity®
The following terms are trademarks of other companies:
Linux® is the trademark of Linus Torvalds in the U.S. and other countries.
Microsoft®, Excel®, Internet Explorer®, Windows Server®, and Windows® are trademarks of Microsoft Corporation in the United States, other countries, or both.
Other company, product, or service names may be trademarks or service marks of others.