Lenovo RackSwitch G8124E

Product Guide (withdrawn product)

Home
Top

Abstract

The Lenovo RackSwitch™ G8124E delivers exceptional performance that is lossless and low latency. In addition, the G8124E delivers excellent cost savings as you consider acquisition costs, energy costs, plus its feature-rich design with when it comes to virtualization, CEE/FCoE, high availability, and its enterprise class Layer 2 and Layer 3 functionality.

This product guide provides essential pre-sales information to understand the structure of the RackSwitch G8124E offering, its key features and specifications, components and options, and configuration guidelines.

This guide is intended for technical specialists, sales specialists, sales engineers, IT architects, and other IT professionals who want to learn more about the RackSwitch G8124E and consider its use in IT solutions.

Notes:

  • This Product Guide describes currently available models of the Lenovo RackSwitch G8124E that support Networking OS version 8.x onwards.
  • For withdrawn models of the RackSwitch G8124E that are no longer available for ordering that support Networking OS up to version 7.x, see the Lenovo Press Product Guide RackSwitch G8124E.

Withdrawn from marketing: This networking switch is now withdrawn from marketing.

Introduction

The Lenovo RackSwitch™ G8124E (as shown in the following figure) delivers exceptional performance that is lossless and low latency. In addition, the G8124E delivers excellent cost savings as you consider acquisition costs, energy costs, plus its feature-rich design with when it comes to virtualization, CEE/FCoE, high availability, and its enterprise class Layer 2 and Layer 3 functionality.

With support for 1 Gb Ethernet or 10 Gb Ethernet, the G8124E switch is designed for those clients that use 10 GbE today or plan to in the future. This switch is the first top of rack (TOR) 10 GbE switch that supports Lenovo Virtual Fabric, which helps clients significantly reduce cost and complexity when it comes to the I/O requirements of most virtualization deployments. Virtual Fabric can help clients reduce the number of multiple I/O adapters down to a single dual-port 10 GbE adapter and reduce the required number of cables and upstream switch ports.

Lenovo RackSwitch G8124E
Figure 1. Lenovo RackSwitch G8124E

Did you know?

The G8124E switch is designed to support several types of configurations from a server or downstream switches: 1 Gb, 10 Gb, virtual NIC, Converged Enhanced Ethernet (CEE/FCoE), and iSCSI. This single switch can handle all of these workloads and can connect to an upstream 1 Gb or 10 Gb infrastructure, or both.

The G8124E supports data center bridging (DCB), which is the IEEE’s group of protocols that provide Lossless Ethernet and allows for clients to reduce the costs of implementing FCoE by using port aggregation before connecting to more costly upstream gateway devices.

The G8124E can be configured in "easy connect" mode to allow for transparent and simple connectivity to the upstream network, which enables easy connectivity to upstream Cisco, Juniper, or other networks without changing those networks.

Virtual Fabric helps clients reduce costs and complexity in environments where they need four or more NICs per server. A perfect example is virtualization, where clients often need as many as eight NICs per dual-port 10 GbE adapter installed in a server.

The G8124E can help clients reduce the complexity of managing VMs and VM migration with VMready® feature that makes the network VM-aware.

Key features

The RackSwitch G8124E switch is considered particularly suited for the following customers:

  • Customers who need ultra-low latency 10 GbE networking
  • Customers who need to converge their SAN and LAN and need a FCoE transit switch
  • Customers who need ways to reduce cost (CAPEX):
    • Converge LAN and SAN traffic
    • Purchase fewer adapters, transceivers, and cables per server
    • Reduce upstream switching costs; fewer ports
  • Customers who need to reduce complexity (OPEX):
    • Fewer adapters to manage
    • Manage fewer cables, which helps reduce potential points of failure
    • Ability to standardize on Ethernet from all servers; Ethernet for all connectivity in a rack
    • Ability to push out FC split to the end of the row

The RackSwitch G8124E offers the following features and benefits:

  • High performance

    The 10 GbE low latency (as low as 570 nanoseconds) switch provides the best combination of extremely low latency, non-blocking line-rate switching, and ease of management.

  • Lower power and better cooling

    The G8124E uses as little power as two 60 W light bulbs, which is a fraction of the power consumption of most competitive offerings. The G8124E rear-to-front cooling design reduces data center air conditioning costs by having airflow match the servers in the rack. In addition, variable speed fans assist in automatically reducing power consumption.

  • Virtual Fabric

    Virtual Fabric can help customers address I/O requirements for multiple NICs while also helping reduce cost and complexity. Virtual Fabric allows for the carving up of a physical NIC into multiple virtual NICs (up to 4 vNICs per 10 Gb physical port) and creates a virtual pipe between the adapter and the switch for improved performance, availability, and security while reducing cost and complexity.

  • VM-aware networking

    VMready software on the switch helps reduce configuration complexity while significantly improving security levels in virtualized environments. VMready automatically detects virtual machine movement from one physical server to another and instantly reconfigures each VM’s network policies across VLANs to keep the network up and running without interrupting traffic or impacting performance. VMready works with all leading VM providers, such as VMware, Citrix Xen, and Microsoft Hyper-V.

  • Layer 3 functionality

    The switch includes Layer 3 functionality, which provides security and performance benefits as inter-VLAN traffic stays within the chassis. This switch also provides the full range of Layer 3 protocols from static routes for technologies, such as Open Shortest Path First (OSPF) and Border Gateway Protocol (BGP) for enterprise customers.

  • Seamless interoperability

    RackSwitch switches interoperate seamlessly with other vendors' upstream switches.

  • Fault tolerance

    These switches learn alternative routes automatically and perform faster convergence if there is a link, switch, or power failure. The switch uses proven technologies, such as L2 trunk failover, advanced VLAN-based failover, VRRP, Hot Links, IGMP V3 snooping, and OSPF.

  • Converged fabric

    The switch supports CEE/DCB and connectivity to FCoE gateways. CEE helps enable clients to combine storage, messaging traffic, VoIP, video, and other data on a common data center Ethernet infrastructure. FCoE helps enable highly efficient block storage over Ethernet for consolidating server network connectivity. As a result, clients can deploy a single server interface for multiple data types, which can simplify deployment and management of server network connectivity while maintaining the high availability and robustness that is required for storage transactions.

  • Transparent networking capability

    With a simple configuration change to Easy Connect mode, the RackSwitch G8124E becomes a transparent network device that is invisible to the core, which eliminates network administration concerns of Spanning Tree Protocol configuration and interoperability and VLAN assignments and avoids any possible loops. By emulating a host NIC to the data center core, it accelerates the provisioning of VMs by eliminating the need to configure the typical access switch parameters.

Components and connectors

The front panel of the RackSwitch G8124E is shown in the following figure.

Front panel of the RackSwitch G8124E
Figure 2. Front panel of the RackSwitch G8124E

The front panel of the G8124E features the following components:

  • LEDs that display the status of the switch and the network.
  • One Mini-USB RS-232 console port that provides another means to configure the switch.
  • 24x SFP/SFP+ ports to attach SFP/SFP+ transceivers for 1 Gb or 10 Gb Ethernet connections or DAC cables for 10 Gb Ethernet connections.
  • Two RJ-45 10/100/1000 Mb Ethernet ports for out-of-band management.

The rear panel of the RackSwitch G8124E is shown in the following figure.

Rear panel of the RackSwitch G8124E
Figure 3. Rear panel of the RackSwitch G8124E

The rear panel of the G8124E features the following components:

  • Two redundant fixed 275 W AC (100 - 240 V) power supplies (IEC 320-C14 power connector)
  • Six fixed fans that provide N+1 redundancy

System specifications

The following table lists the RackSwitch G8124E system specifications.

Table 1. System specifications
Attribute Specification
Form factor 1U rack mount
Ports 24x SFP/SFP+ ports
SFP/SFP+ media types 10 Gb Ethernet SFP+:
  • 10 GbE short-range (SR) SFP+ transceivers
  • 10 GbE long-range (LR) SFP+ transceivers
  • 10 GbE extended-range (ER) SFP+ transceivers
  • 10 GbE RJ-45 SFP+ transceivers
  • 10 GbE SFP+ active optical cables (AOCs)
  • 10 GbE SFP+ direct attach copper (DAC) cables
1/10 Gb Ethernet SFP+:
  • 1/10 GbE SX/SR SFP+ transceivers
1 Gb Ethernet SFP:
  • 1 GbE short-wavelength (SX) SFP transceivers
  • 1 GbE long-wavelength (LX) SFP transceivers
  • 1 GbE RJ-45 SFP transceivers
Port speeds
  • 10 GbE SFP+ transceivers, DAC cables and AOCs: 10 Gbps
  • 1/10 GbE SFP+ transceivers: 1 Gbps or 10 Gbps
  • 1 GbE SFP transceivers: 1 Gbps
Switching method Cut-through.
Data traffic types Unicast, multicast, broadcast.
Software features

Lenovo Networking OS:

Layer 2 switching, Layer 3 switching, virtual local area networks (VLANs), VLAN tagging, spanning tree protocol (STP), link aggregation (trunk) groups (LAGs), virtual LAGs (vLAGs), Hot Links, Layer 2 failover, quality of service (QoS), VMready, IPv4/IPv6 management, IPv4/IPv6 routing, IPv4 virtual router redundancy protocol (VRRP), virtual NICs, Converged Enhanced Ethernet, Fibre Channel over Ethernet (FCoE) transit switch operations.
Performance Non-blocking architecture with wire-speed forwarding of traffic:
  • 100% line-rate performance
  • Up to 480 Gbps aggregated throughput
  • As low as 570 nanoseconds switching latency
  • Up to 9,216-byte jumbo frames
  • Receive buffer size: 2 MB
Scalability
  • MAC address forwarding database entries: 16,000
  • VLANs: 4,095
  • Per VLAN Rapid Spanning Tree (PVRST) instances: 128
  • Multiple STP (MSTP) instances: 32
  • Link aggregation groups: 16
  • Ports in a link aggregation group: 12
Cooling Six 5+1 redundant fixed fans. Rear (non-port side) to front (port side) or front to rear airflow.
Power supply Two load-sharing, redundant fixed 275 W AC (100 - 240 V) power supplies (1x IEC 320-C14 connector on each power supply).
Hot-swap parts SFP/SFP+ transceivers, SFP+ DAC cables.
Management ports 2x 10/100/1000 Mb Ethernet ports (RJ-45); 1x RS-232 port (Mini-USB).
Management interfaces Industry standard command line interface (isCLI); SNMP v1 and v3; Netconf (XML). Optional Lenovo XClarity for discovery, inventory, monitoring and events.
Security features Secure Shell (SSH); Secure Copy (SCP); Secure FTP (sFTP); user level security; Role-based Access Control (RBAC); LDAP/LDAPS, RADIUS, and TACACS+ authentication; access control lists (ACLs); port-based network access control (IEEE 802.1x).
Hardware warranty Three-year Customer Replaceable Unit limited warranty with 9x5 Next Business Day Parts Delivered. Optional warranty service upgrades are available through Lenovo: onsite service, 24x7 coverage, 2-hour or 4-hour response time, 1-year or 2-year post-warranty extensions, Premier support, and basic installation services.
Software maintenance Three-year software support and subscription is included in the base warranty. Optional 1-year and 2-year warranty extensions include software support and subscription.
Mean Time Between Failures 189,060 hours with ambient operating temperature of 40° C.
Dimensions Height: 44 mm (1.7 in.); width: 439 mm (17.3 in.); depth: 381 mm (15.0 in.)
Weight 6.4 kg (14.1 lb).

Models

The following table lists the G8124E switch models.

Table 2. G8124E switch models
Description Part number Machine Type-Model Feature code
Lenovo RackSwitch G8124E (Rear to Front) 7159BR6 7159-HC9 AT0B
Lenovo RackSwitch G8124E (Front to Rear) 7159BF7 7159-HC7 AT0C

The part numbers for the G8124E switches include the following items:

  • One Lenovo RackSwitch G8124E switch
  • Generic Rack Mount Kit (2-post)
  • Console Cable Kit:
    • RJ-45 (plug) to RJ-45 (plug) serial cable (1 m)
    • Mini-USB to RJ-45 (jack) adapter cable (0.2 m) with retention clip
    • DB-9 to RJ-45 (jack) adapter
  • Documentation package

Configuration notes:

  • Power cables are not included and must be ordered together with the switch (see "Power supplies and cables" for details).
  • SFP/SFP+ transceivers and cables are not included and must be ordered together with the switch (see "Transceivers and cables" for details).

Transceivers and cables

With the flexibility of the G8124E switch, customers can choose the following connectivity technologies:

  • For 1 GbE links, customers can use RJ-45 SFP transceivers with UTP cables up to 100 meters. For longer distances, the 1000BASE-SX transceiver can support distances up to 220 meters with 62.5 µ (OM1) or up to 550 meters on 50 µ (OM2) multi-mode fiber optic cables, or the 1000BASE-LX transceiver can support distances up to 10 kilometers on single-mode fiber optic cables (1310 nm).
  • For 10 GbE links, customers can use direct-attached copper (DAC) SFP+ cables for in-rack cabling for distances up to 7 meters or SFP+ active optical cables (AOCs) for distances up to 20 meters. These cables have SFP+ connectors on each end, and they do not need separate transceivers. For distances up to 30 meters, the 10GBASE-T SFP+ transceiver can be used with Category 6a or 7 RJ-45 UTP cables.

    For longer distances, the 10GBASE-SR transceiver can support distances up to 300 meters on OM3 or up to 400 meters on OM4 multimode fiber optic cables. The 10GBASE-LR transceivers can support distances up to 10 kilometers on single mode fiber optic cables.

    For extended distances, the 10GBASE-ER transceivers can support distances up to 40 kilometers on single mode fiber optic cables.

The supported cables and transceivers are listed in the following table.

Table 3. Supported SFP/SFP+ transceivers and DAC cables
Description Part number Feature code Maximum quantity
SFP transceivers - 1 GbE
Lenovo 1000BASE-T (RJ-45) SFP Transceiver (no 10/100 Mbps support) 00FE333 A5DL 24
Lenovo 1000BASE-SX SFP Transceiver 81Y1622 3269 24
Lenovo 1000BASE-LX SFP Transceiver 90Y9424 A1PN 24
UTP Category 5E cables for 1 GbE SFP RJ-45 transceivers and 1 GbE RJ-45 management ports
0.6m Green Cat5e Cable 40K5563 3796 26
1.5m Blue Cat5e Cable 40K8785 3802 26
1.5m Green Cat5e Cable 40K5643 3797 26
3m Blue Cat5e Cable 40K5581 3803 26
3m Green Cat5e Cable 40K5793 3798 26
3m Yellow Cat5e Cable 40K8957 3793 26
10m Blue Cat5e Cable 40K8927 3804 26
10m Green Cat5e Cable 40K5794 3799 26
25m Blue Cat5e Cable 40K8930 3805 26
25m Green Cat5e Cable 40K8869 3800 26
SFP+ transceivers - 10 GbE
Lenovo Dual Rate 1/10Gb SX/SR SFP+ Transceiver 00MY034 ATTJ 24
Lenovo 10Gb SFP+ SR Transceiver (10GBASE-SR) 46C3447 5053 24
Lenovo 10Gb SFP+ LR Transceiver (10GBASE-LR) 90Y9412 A1PM 24
Lenovo 10GBASE-LR SFP+ Transceiver 00FE331 B0RJ 24
Lenovo 10Gb SFP+ ER Transceiver (10GBASE-ER) 90Y9415 A1PP 24
Lenovo 10GBASE-T SFP+ Transceiver 7G17A03130 AVV1 24
Optical cables for 1 GbE SFP SX and 10 GbE SFP+ SR transceivers
Lenovo 0.5m LC-LC OM3 MMF Cable 00MN499 ASR5 24
Lenovo 1m LC-LC OM3 MMF Cable 00MN502 ASR6 24
Lenovo 3m LC-LC OM3 MMF Cable 00MN505 ASR7 24
Lenovo 5m LC-LC OM3 MMF Cable 00MN508 ASR8 24
Lenovo 10m LC-LC OM3 MMF Cable 00MN511 ASR9 24
Lenovo 15m LC-LC OM3 MMF Cable 00MN514 ASRA 24
Lenovo 25m LC-LC OM3 MMF Cable 00MN517 ASRB 24
Lenovo 30m LC-LC OM3 MMF Cable 00MN520 ASRC 24
UTP Category 6 cables for 1 GbE SFP and 10 GbE SFP+ RJ-45 transceivers, and 1 GbE RJ-45 management ports
10m Cat6 Blue Cable 90Y3721 A1MU 26
10m Cat6 Green Cable 90Y3718 A1MT 26
10m Cat6 Yellow Cable 90Y3715 A1MS 26
25m Cat6 Blue Cable 90Y3730 A1MX 26
25m Cat6 Green Cable 90Y3727 A1MW 26
25m Cat6 Yellow Cable 90Y3724 A1MV 26
SFP+ active optical cables - 10 GbE
Lenovo 1m SFP+ to SFP+ Active Optical Cable 00YL634 ATYX 24
Lenovo 3m SFP+ to SFP+ Active Optical Cable 00YL637 ATYY 24
Lenovo 5m SFP+ to SFP+ Active Optical Cable 00YL640 ATYZ 24
Lenovo 7m SFP+ to SFP+ Active Optical Cable 00YL643 ATZ0 24
Lenovo 15m SFP+ to SFP+ Active Optical Cable 00YL646 ATZ1 24
Lenovo 20m SFP+ to SFP+ Active Optical Cable 00YL649 ATZ2 24
SFP+ passive direct-attach cables - 10 GbE
Lenovo 0.5m Passive DAC SFP+ Cable 00D6288 A3RG 24
Lenovo 1m Passive DAC SFP+ Cable 90Y9427 A1PH 24
Lenovo 1.5m Passive DAC SFP+ Cable 00AY764 A51N 24
Lenovo 2m Passive DAC SFP+ Cable 00AY765 A51P 24
Lenovo 3m Passive DAC SFP+ Cable 90Y9430 A1PJ 24
Lenovo 5m Passive DAC SFP+ Cable 90Y9433 A1PK 24
Lenovo 7m Passive DAC SFP+ Cable 00D6151 A3RH 24
SFP+ active direct-attach cables - 10 GbE
Lenovo 1m Active DAC SFP+ Cable 00VX111 AT2R 24
Lenovo 3m Active DAC SFP+ Cable 00VX114 AT2S 24
Lenovo 5m Active DAC SFP+ Cable 00VX117 AT2T 24
Spare console cables
Console Cable Kit Spare (RJ-45/DB9) 90Y9462 A2MG 1

The network cables that can be used with the switch are listed in the following table.

Table 4. G8124E network cabling requirements
Transceiver Standard Cable Connector
10 Gb Ethernet
10Gb SR SFP+ (46C3447)
1/10Gb SFP+ (00MY034)
10GBASE-SR Up to 30 m with fiber optic cables supplied by Lenovo (see Table 3); up to 300 m with OM3 or up to 400 m with OM4 multimode fiber optic cable LC
10Gb LR SFP+
(90Y9412, 00FE331)
10GBASE-LR 1310 nm single-mode fiber cable up to 10 km LC
10Gb ER SFP+ (90Y9415) 10GBASE-ER 1310 nm single-mode fiber cable up to 40 km LC
10Gb RJ-45 SFP+ (7G17A03130) 10GBASE-T Up to 25 m with UTP Category 6 cables supplied by Lenovo (see Table 3); UTP Category 6a or 7 cables up to 30 m RJ-45
Active optical cable 10GBASE-SR SFP+ active optical cables up to 20 m (see Table 3) SFP+
Direct attach copper cable 10GSFP+Cu SFP+ DAC cables up to 7 m (see Table 3) SFP+
1 Gb Ethernet
1Gb RJ-45 SFP (00FE333) 1000BASE-T Up to 25 m with UTP Category 5E or 6 cables supplied by Lenovo (see Table 3); UTP Category 5, 5E, or 6 up to 100 m RJ-45
1Gb SX SFP (81Y1622)
1/10Gb SFP+ (00MY034)
1000BASE-SX Up to 30 m with fiber optic cables supplied by Lenovo (see Table 3); 850 nm multimode fiber cable 50 µ (OM2) up to 550 m or 62.5 µ (OM1) up to 220 m LC
1Gb LX SFP (90Y9424) 1000BASE-LX 1310 nm single-mode fiber cable up to 10 km LC
Management ports
1 GbE management ports 1000BASE-T Up to 25 m with UTP Category 5E or 6 cables supplied by Lenovo (see Table 3); UTP Category 5, 5E, or 6 up to 100 m RJ-45
RS-232 management port RS-232 DB-9/RJ-45-to-mini-USB console cable (comes with the switch) Mini-USB

Software features

Note: The software features that are listed in this section are based on Networking OS 8.4.

The RackSwitch G8124E has the following software features:

  • Scalability and performance:
    • Media access control (MAC) address learning with automatic updates
    • Up to 128 IP interfaces per switch (interfaces 127 and 128 are reserved for switch management)
    • Static and LACP (IEEE 802.3ad) link aggregation
    • Broadcast/multicast storm control
    • IGMP snooping to limit flooding of IP multicast traffic
    • IGMP filtering to control multicast traffic for hosts that are participating in multicast groups
    • Configurable traffic distribution schemes over trunk links that are based on source and destination IP or MAC addresses, or both
    • Fast port forwarding and fast uplink convergence for rapid STP convergence
  • Availability and redundancy:
    • IEEE 802.1D STP for providing L2 redundancy
    • IEEE 802.1s Multiple STP (MSTP) for topology optimization
    • IEEE 802.1w Rapid STP (RSTP) provides rapid STP convergence for critical delay-sensitive traffic, such as voice or video
    • Per-VLAN Rapid STP (PVRST) enhancements
    • Layer 2 Trunk Failover to support active/standby configurations of network adapter teaming on compute nodes
    • Hot Links provides basic link redundancy with fast recovery for network topologies that require Spanning Tree to be turned off
  • VLAN support:
    • Up to 4095 VLANs supported per switch, with VLAN numbers 1 - 4095 (VLAN 4095 is used by the management network.)
    • Port-based VLANs
    • 802.1Q VLAN tagging
    • Private VLANs
  • Security:
    • VLAN-based, MAC-based, and IP-based access control lists (ACLs)
    • 802.1x port-based authentication
    • Multiple user IDs and passwords
    • User access control
    • Radius, TACACS+ and LDAP/LDAPS authentication and authorization
    • NIST 800-131A Encryption
    • Selectable encryption protocol
    • Secure Input/Output Module (SIOM) policy: Secure and Legacy modes
  • Quality of Service (QoS):
    • Support for IEEE 802.1p, IP ToS/DSCP, and ACL-based (MAC/IP source and destination addresses and VLANs) traffic classification and processing
    • Traffic shaping and re-marking that is based on defined policies
    • Eight output Class of Service (COS) queues per port for processing qualified traffic
    • IPv4/IPv6 ACL metering
  • IP v4 Layer 3 functions:
    • Host management
    • IP forwarding
    • IP filtering with ACLs, up to 127 IPv4 ACLs supported
    • VRRP for router redundancy
    • Up to 128 static routes
    • Routing protocols (RIP v1, RIP v2, OSPF v2, BGP)
    • DHCP Relay
    • IGMP snooping
    • Protocol Independent Multicast (PIM) in Sparse Mode (PIM-SM) and Dense Mode (PIM-DM).
  • IPv6 Layer 3 functions:
    • IPv6 host management
    • IPv6 forwarding
    • Support for OSPF v3 routing protocol
    • IPv6 filtering with ACLs, up to 128 IPv6 ACLs supported
  • Virtualization:
    • Virtual NICs (vNICs) with Ethernet, iSCSI, or FCoE traffic on vNICs
    • Virtual link aggregation groups (vLAGs)
      • Two switches (vLAG peers) act as a single virtual entity for a multi-port aggregation
      • vLAG Peer Gateway for improved usage of the inter-switch link between the vLAG peers
      • Two-tier vLAGs with VRRP enables active/active VRRP support to reduce routing latency
    • VMready support:
      • Up to 2,048 virtual entities (VEs)
      • Automatic VE discovery
      • Up to 1,024 local or distributed VM groups for VEs
      • NMotion® feature for automatic network configuration migration
  • Converged Enhanced Ethernet:
    • Priority-Based Flow Control (PFC) (IEEE 802.1Qbb) extends 802.3x standard flow control to allow the switch to pause traffic that is based on the 802.1p priority value in each packet’s VLAN tag.
    • Enhanced Transmission Selection (ETS) (IEEE 802.1Qaz) provides a method for allocating link bandwidth that is based on the 802.1p priority value in each packet’s VLAN tag.
    • Data Center Bridging Capability Exchange Protocol (DCBX) (IEEE 802.1AB) allows neighboring network devices to exchange information about their capabilities.
  • Fibre Channel over Ethernet (FCoE):
    • FC-BB5 FCoE specification compliant
    • FCoE transit switch operations
    • FCoE Initialization Protocol (FIP) support for automatic ACL configuration
    • Link Aggregation Group (LAG) support for FCoE traffic
    • Supports 2,048 FCoE sessions with FIP Snooping by using Class ID ACLs
  • Manageability:
    • Industry-standard command line interface (isCLI)
    • Simple Network Management Protocol (SNMP V1 and V3)
    • Telnet interface for CLI
    • Secure Shell (SSH) v1 and v2 for CLI
    • Secure Copy (SCP) for uploading and downloading the switch configuration via secure channels
    • Link Layer Discovery Protocol (LLDP) for discovering network devices
    • Serial interface for CLI
    • Scriptable CLI
    • Dual software images
    • Firmware image update via TFTP, FTP, and Secure FTP (sFTP)
    • Network Time Protocol (NTP) for switch clock synchronization
    • Netconf (XML)
    • Lenovo XClarity (optional) for discovery, inventory, monitoring and events
  • Monitoring:
    • Switch LEDs for port status and switch status indication
    • Remote Monitoring (RMON) agent to collect statistics and proactively monitor switch performance
    • Port mirroring for analyzing network traffic passing through switch
    • Change tracking and remote logging with syslog feature
    • sFlow agent for monitoring traffic in data networks (separate sFlow analyzer required elsewhere)

The following features are not supported with IPv6:

  • Bootstrap Protocol (BOOTP) and DHCP
  • RADIUS, TACACS+ and LDAP
  • VMware Virtual Center (vCenter) for VMready
  • Routing Information Protocol (RIP)
  • Border Gateway Protocol (BGP)
  • Protocol Independent Multicast (PIM)
  • Virtual Router Redundancy Protocol (VRRP)
  • sFlow

Ethernet standards

The switch supports the following Ethernet standards:

  • IEEE 802.1AB Data Center Bridging Capability Exchange Protocol (DCBX)
  • IEEE 802.1D Spanning Tree Protocol (STP)
  • IEEE 802.1p Class of Service (CoS) prioritization
  • IEEE 802.1s Multiple STP (MSTP)
  • IEEE 802.1Q Tagged VLAN
  • IEEE 802.1Qbb Priority-Based Flow Control (PFC)
  • IEEE 802.1Qaz Enhanced Transmission Selection (ETS)
  • IEEE 802.1x port-based authentication
  • IEEE 802.1w Rapid STP (RSTP)
  • IEEE 802.3 10BASE-T Ethernet
  • IEEE 802.3ab 1000BASE-T copper twisted pair Gigabit Ethernet
  • IEEE 802.3ad Link Aggregation Control Protocol
  • IEEE 802.3ae 10GBASE-SR short range fiber optics 10 Gb Ethernet
  • IEEE 802.3ae 10GBASE-LR long range fiber optics 10 Gb Ethernet
  • IEEE 802.3ae 10GBASE-ER extended range fiber optics 10 Gb Ethernet
  • IEEE 802.3u 100BASE-TX Fast Ethernet
  • IEEE 802.3x Full-duplex Flow Control
  • IEEE 802.3z 1000BASE-SX short range fiber optics Gigabit Ethernet
  • IEEE 802.3z 1000BASE-LX long range fiber optics Gigabit Ethernet

Power supplies and cables

The G8124E switch has two load-sharing, 275 W AC (100 - 240 V) redundant fixed power supplies. Each power supply has an individual IEC 320-C14 connector.

The G8124E switch ships standard without any AC power cables. The part numbers and feature codes to order the power cables (two power cables are required per switch) are listed in the following table.

Table 5. AC power cable options
Description Part number Feature code
Rack power cables
1.5m, 10A/100-250V, C13 to IEC 320-C14 Rack Power Cable 39Y7937 6201
1.8m, 10A/100-250V, 2xC13PM to IEC 320-C14 Rack Power Cable None* 6568
2.8m, 10A/100-250V, C13 to IEC 320-C14 Rack Power Cable None* 6311
2.8m, 10A/100-250V, C13 to IEC 320-C20 Rack Power Cable 39Y7938 6204
4.3m, 10A/100-250V, C13 to IEC 320-C14 Rack Power Cable 39Y7932 6263
Line cords
Argentina 10A/250V C13 to IRAM 2073 2.8m line cord 39Y7930 6222
Australia/NZ 10A/250V C13 to AS/NZ 3112 2.8m line cord 39Y7924 6211
Brazil 10A/125V C13 to NBR 6147 2.8m line cord 39Y7929 6223
China 10A/250V C13 to GB 2099.1 2.8m line cord 39Y7928 6210
Denmark 10A/250V C13 to DK2-5a 2.8m line cord 39Y7918 6213
European 10A/230V C13 to CEE7-VII 2.8m line cord 39Y7917 6212
India 10A/250V C13 to IS 6538 2.8m line cord 39Y7927 6269
Israel 10A/250V C13 to SI 32 2.8m line cord 39Y7920 6218
Japan 12A/125V C13 to JIS C-8303 2.8m line cord 46M2593 A1RE
Korea 12A/250V C13 to KETI 2.8m line cord 39Y7925 6219
South Africa 10A/250V C13 to SABS 164 2.8m line cord 39Y7922 6214
Switzerland 10A/250V C13 to SEV 1011-S24507 2.8m line cord 39Y7919 6216
United Kingdom 10A/250V C13 to BS 1363/A 2.8m line cord 39Y7923 6215
United States 10A/125V C13 to NEMA 5-15P 4.3m line cord 39Y7931 6207
United States 10A/250V C13 to NEMA 6-15P 2.8m line cord 46M2592 A1RF

* Available for factory-built custom configurations and solutions only.

Rack installation

The G8124E switch includes a 2-post rack mount kit.

For 4-post rack installations, the G8124E switch supports the optional adjustable 19-inch, 4-post rail kit and the air inlet duct (optional for the 4-post rail kit; supported only with the models with rear to front airflow).

When the G8124E switch (front to rear airflow) is installed in the Intelligent Cluster Rack (Machine Type 1410) or Enterprise Rack (Machine Type 9363) as a part of a NeXtScale System solution, the recessed 19-inch 4-post rail kit is required.

The following table lists rack installation options for the G8124E switches with rear to front and front to rear airflow.

Table 6. Rack installation options
Description Part number Feature code
Rear to front airflow (7159-HC9)
Lenovo RackSwitch Adjustable 19" 4 Post Rail Kit 00D6185 A3KP
Air Inlet Duct for 382 mm RackSwitch 00D6062 A3HG
Front to rear airflow (7159-HC7)
Lenovo RackSwitch Adjustable 19" 4 Post Rail Kit 00D6185 A3KP
Lenovo RackSwitch Recessed 19" 4 Post Rail Kit 00CG089 A51M

Physical specifications

The G8124E switch features the following approximate dimensions and weight:

  • Height: 44 mm (1.7 in.)
  • Width: 439 mm (17.3 in.)
  • Depth: 381 mm (15.0 in.)
  • Weight: 6.4 kg (14.1 lb)

Operating environment

The G8124E switch is supported in the following operating environment:

  • Temperature: 0 - 40 ºC (32 - 104 ºF).
  • Relative humidity: Non-condensing, 10 - 90%
  • Altitude: up to 3,050 m (10,000 feet)
  • Acoustic noise: Less than 65 dB
  • Airflow: Front-to-rear or rear-to-front cooling with variable speed fans for reduced power draw
  • Electrical input: 50-60 Hz, 100-240 V AC auto-switching
  • Electrical power: 200 W (typical)
  • Heat dissipation: 1,100 BTU/hour (maximum)

Warranty and maintenance

The RackSwitch G8124E comes with a 3-year Customer Replaceable Unit (CRU) hardware limited warranty with 9x5 Next Business Day (NBD) Parts Delivered and includes a 3-year software license, which provides entitlement to upgrades over that period. The options that are installed in the switch assume the switch’s base warranty and any Lenovo warranty service upgrade for the switch.

Some regions might have different warranty terms and conditions than the standard warranty. This is due to local business practices or laws in the specific region. Local service teams can assist in explaining region-specific terms when needed. Examples of region-specific warranty terms are second or longer business day parts delivery or parts-only base warranty.

If warranty terms and conditions include onsite labor for repair or replacement of parts, Lenovo will dispatch a service technician to the customer site to perform the replacement. Onsite labor under base warranty is limited to labor for replacement of parts that have been determined to be field-replaceable units (FRUs). Parts that are determined to be customer-replaceable units (CRUs) do not include onsite labor under base warranty.

If warranty terms include parts-only base warranty, Lenovo is responsible for delivering only replacement parts that are under base warranty (including FRUs) that will be sent to a requested location for self-service. Parts-only service does not include a service technician being dispatched onsite. Parts must be changed at customer’s own cost and labor and defective parts must be returned following the instructions supplied with the spares parts.

Also available are Lenovo Services warranty maintenance upgrades and post-warranty maintenance agreements, with a well-defined scope of services, including service hours, response time, term of service, and service agreement terms and conditions.

Lenovo warranty service upgrade offerings are region-specific. Not all warranty service upgrades are available in every region. For information about Lenovo warranty service upgrade offerings that are available in your region, refer to the following resources:

In general, the following Lenovo warranty service upgrades are available:

  • Warranty and maintenance service upgrades:
    • 3, 4, or 5 years of warranty service coverage
    • 1-year or 2-year post-warranty extensions
    • Foundation Service: 9x5 service coverage with next business day onsite response
    • Essential Service: 24x7 service coverage with 4-hour onsite response or 24-hour committed repair (available only in select regions)
    • Advanced Service: 24x7 service coverage with 2-hour onsite response or 6-hour committed repair (available only in select regions)
  • Premier Support

    Premier Support service offers direct access to Lenovo’s most advanced technicians for faster troubleshooting with single point of contact for end-to-end problem resolution and collaborative third-party software support.

  • Basic Hardware Installation Services

    Lenovo experts can seamlessly manage the physical installation of your server, storage, or networking hardware. Working at a time convenient for you (business hours or off shift), the technician will unpack and inspect the systems on your site, install options, mount in a rack cabinet, connect to power and network, check and update firmware to the latest levels, verify operation, and dispose of the packaging, allowing your team to focus on other priorities.

For service definitions, region-specific details, and service limitations, please refer to the following documents:

Regulatory compliance

The switch conforms to the following regulations:

  • Safety certifications:
    • UL60950-1
    • CAN/CSA 22.2 No.60950-1
    • EN 60950-1
    • IEC60950-1
    • NOM NYCE 019
    • GOST R MEK 60950-1
    • GB4943-2001
  • Electromagnetic compatibility certifications:
    • FCC 47CFR Part 15 Class A
    • EN 55022 Class A
    • ICES-003 Class A
    • VCCI Class A
    • AS/NZS CISPR 22 Class A
    • CISPR 22 Class A
    • EN 55024
    • EN 300386
    • CE
  • Environmental: Reduction of Hazardous Substances (ROHS) 6

Network connectivity

The following table lists the network switches with rear-to-front airflow that are offered by Lenovo that can be used with the RackSwitch G8124E for ThinkSystem and Flex System network connectivity.

Table 7. Network switches (rear-to-front airflow)
Description Part number
1 Gb Ethernet switches
Lenovo ThinkSystem NE0152T RackSwitch (Rear to Front) 7Y810011WW
Lenovo ThinkSystem NE0152TO RackSwitch (Rear to Front, ONIE) 7Z320O11WW
Lenovo RackSwitch G7028 (Rear to Front) 7159BAX
Lenovo RackSwitch G7052 (Rear to Front) 7159CAX
Lenovo RackSwitch G8052 (Rear to Front) 7159G52
10 Gb Ethernet switches
Lenovo ThinkSystem NE1032 RackSwitch (Rear to Front) 7159A1X
Lenovo ThinkSystem NE1032T RackSwitch (Rear to Front) 7159B1X
Lenovo ThinkSystem NE1072T RackSwitch (Rear to Front) 7159C1X
Lenovo RackSwitch G8272 (Rear to Front) 7159CRW
Lenovo RackSwitch G8296 (Rear to Front) 7159GR6
25 Gb Ethernet switches (10 GbE connectivity out of an SFP28 port)
Lenovo ThinkSystem NE2572 RackSwitch (Rear to Front) 7159E1X
Lenovo ThinkSystem NE2572O RackSwitch (Rear to Front, ONIE) 7Z210O21WW
100 Gb Ethernet switches (4x 10 GbE breakout connectivity out of a QSFP28 port)
Lenovo ThinkSystem NE10032 RackSwitch (Rear to Front) 7159D1X
Lenovo ThinkSystem NE10032O RackSwitch (Rear to Front, ONIE) 7Z210O11WW

The following table lists the network switches with front-to-rear airflow that are offered by Lenovo that can be used with the RackSwitch G8124E for NeXtScale System network connectivity.

Table 8. Network switches (front-to-rear airflow)
Description Part number
1 Gb Ethernet switches
Lenovo RackSwitch G8052 (Front to Rear) 715952F
10 Gb Ethernet switches
Lenovo ThinkSystem NE1032 RackSwitch (Front to Rear) 7159A2X
Lenovo ThinkSystem NE1032T RackSwitch (Front to Rear) 7159B2X
Lenovo ThinkSystem NE1072T RackSwitch (Front to Rear) 7159C2X
Lenovo RackSwitch G8272 (Front to Rear) 7159CFV
Lenovo RackSwitch G8296 (Front to Rear) 7159GF5
25 Gb Ethernet switches (10 GbE connectivity out of an SFP28 port)
Lenovo ThinkSystem NE2572 RackSwitch (Front to Rear) 7159E2X
100 Gb Ethernet switches (4x 10 GbE breakout connectivity out of a QSFP28 port)
Lenovo ThinkSystem NE10032 RackSwitch (Front to Rear) 7159D2X

For more information, see the list of Product Guides in the Top-of-rack Switches category:
http://lenovopress.com/servers/options/switches

Storage connectivity

The following table lists the external storage systems that are currently offered by Lenovo that can be used with the RackSwitch G8124E for external NAS or iSCSI SAN storage connectivity.

Table 9. External storage systems: DE Series
Description Part number
Worldwide Japan
Lenovo ThinkSystem DE Series Storage (iSCSI connectivity)
Lenovo ThinkSystem DE2000H 10GBASE-T Hybrid Flash Array LFF 7Y70A003WW 7Y701001JP
Lenovo ThinkSystem DE2000H 10GBASE-T Hybrid Flash Array SFF 7Y71A002WW 7Y711005JP
Lenovo ThinkSystem DE2000H iSCSI Hybrid Flash Array LFF 7Y70A004WW 7Y701000JP
Lenovo ThinkSystem DE2000H iSCSI Hybrid Flash Array SFF 7Y71A003WW 7Y711006JP
Lenovo ThinkSystem DE4000H iSCSI Hybrid Flash Array 4U60 7Y77A000WW 7Y771002JP
Lenovo ThinkSystem DE4000H iSCSI Hybrid Flash Array LFF 7Y74A002WW 7Y74A002JP
Lenovo ThinkSystem DE4000H iSCSI Hybrid Flash Array SFF 7Y75A001WW 7Y75A001JP
Lenovo ThinkSystem DE4000F iSCSI All Flash Array SFF 7Y76A002WW 7Y76A002JP
Lenovo ThinkSystem DE6000H iSCSI Hybrid Flash Array 4U60 7Y80A002WW 7Y801000JP
Lenovo ThinkSystem DE6000H iSCSI Hybrid Flash Array SFF 7Y78A002WW 7Y781000JP
Lenovo ThinkSystem DE6000F iSCSI All Flash Array SFF 7Y79A002WW 7Y79A002JP
Table 10. External storage systems: DM Series
Description Part number
Lenovo ThinkSystem DM Series Storage (NAS or iSCSI connectivity)
Lenovo ThinkSystem DM3000H Hybrid Storage Array (2U12 LFF, CTO only) 7Y42CTO1WW
Lenovo ThinkSystem DM3000H 48TB (12x 4TB HDDs) (Universal SFP+) 7Y420001EA*
Lenovo ThinkSystem DM3000H 48TB (12x 4TB HDDs) (10GBASE-T) 7Y420002EA*
Lenovo ThinkSystem DM5000H Hybrid Storage Array (2U24 SFF, CTO only) 7Y57CTO1WW
Lenovo ThinkSystem DM5000H 11.5TB (12x 960GB SSDs) (Universal SFP+) 7Y570001EA*
Lenovo ThinkSystem DM5000H 11.5TB (12x 960GB SSDs) (10GBASE-T) 7Y570002EA*
Lenovo ThinkSystem DM5000H 29TB (24x 1.2TB 10K HDDs) (Universal SFP+) 7Y570003EA*
Lenovo ThinkSystem DM5000H 29TB (24x 1.2TB 10K HDDs) (10GBASE-T) 7Y570004EA*
Lenovo ThinkSystem DM5000F Flash Storage Array (2U24 SFF, CTO only) 7Y41CTO1WW
Lenovo ThinkSystem DM7000H Hybrid Storage Array (3U, CTO only) 7Y56CTO1WW
Lenovo ThinkSystem DM7000F Flash Storage Array (3U, CTO only) 7Y40CTO1WW

* Available only in EMEA.

Table 11. External storage systems: DS Series
Description Part number
Worldwide Japan PRC
Lenovo ThinkSystem DS Series Storage (iSCSI connectivity)
Lenovo ThinkSystem DS2200 LFF FC/iSCSI Dual Controller Unit 4599A31 4599A3J 4599A3C
Lenovo ThinkSystem DS2200 SFF FC/iSCSI Dual Controller Unit 4599A11 4599A1J 4599A1C
Lenovo ThinkSystem DS4200 LFF FC/iSCSI Dual Controller Unit 4617A31 4617A3J 4617A3C
Lenovo ThinkSystem DS4200 SFF FC/iSCSI Dual Controller Unit 4617A11 4617A1J 4617A1C
Lenovo ThinkSystem DS6200 SFF FC/iSCSI Dual Controller Unit 4619A11 4619A1J 4619A1C
DS6200F 12x 400GB 10DWD SSDs, 1x 8Gb FC SFP, 512 Snapshots, Replication 4619A1F 4619J1F 4619C1F
DS6200F 12x 800GB 3DWD SSDs, 1x 8Gb FC SFP, 512 Snapshots, Replication 4619A2F 4619J2F 4619C2F
DS6200F 12x 1.6TB 3DWD SSDs, 1x 8Gb FC SFP, 512 Snapshots, Replication 4619A3F 4619J3F 4619C3F
DS6200F 12x 3.84TB 1DWD SSDs, 1x 8Gb FC SFP, 512 Snapshots, Replication 4619A4F 4619J4F 4619C4F
Table 12. External storage systems: V Series and Storwize for Lenovo
Description Part number
Lenovo Storage V Series (iSCSI connectivity)
Lenovo Storage V3700 V2 LFF Control Enclosure 6535C1D
Lenovo Storage V3700 V2 SFF Control Enclosure 6535C2D
Lenovo Storage V3700 V2 XP LFF Control Enclosure 6535C3D
Lenovo Storage V3700 V2 XP SFF Control Enclosure 6535C4D
Lenovo Storage V5030 LFF Control Enclosure 3Yr S&S 6536C12
Lenovo Storage V5030 LFF Control Enclosure 5Yr S&S 6536C32
Lenovo Storage V5030 SFF Control Enclosure 3Yr S&S 6536C22
Lenovo Storage V5030 SFF Control Enclosure 5Yr S&S 6536C42
Lenovo Storage V5030F SFF Control Enclosure 3Yr S&S 6536B1F
Lenovo Storage V5030F SFF Control Enclosure 5Yr S&S 6536B2F
Lenovo Storage V7000 SFF Control Enclosure 3Yr S&S PRC 6538R11^
Lenovo Storage V7000 SFF Control Enclosure 5Yr S&S PRC 6538R21^
Lenovo Storage V7000F SFF Control Enclosure 3Yr S&S PRC 6538R1G^
Lenovo Storage V7000F SFF Control Enclosure 5Yr S&S PRC 6538R2G^
IBM Storwize for Lenovo (iSCSI connectivity)
IBM Storwize V7000 SFF Control Enclosure, 3YR SWMA 6195C32†
IBM Storwize V7000 SFF Control Enclosure, 3YR SWMA, LA 6195C3L‡
IBM Storwize V7000 SFF Control Enclosure, 5YR SWMA 6195C52†
IBM Storwize V7000 SFF Control Enclosure, 5YR SWMA, LA 6195C5L‡

^ Available only in PRC.
† Available worldwide except Latin America.
‡ Available only in Latin America.

For more information, see the list of Product Guides in the following categories:

Rack cabinets

The following table lists the rack cabinets that are offered by Lenovo that can be used in RackSwitch G8124E solutions.

Table 13. Rack cabinets
Description Part number
25U S2 Standard Rack (1000 mm deep; 2 sidewall compartments) 93072RX
25U Static S2 Standard Rack (1000 mm deep; 2 sidewall compartments) 93072PX
42U S2 Standard Rack (1000 mm deep; 6 sidewall compartments) 93074RX
42U 1100mm Enterprise V2 Dynamic Rack (6 sidewall compartments) 93634PX
42U 1100mm Enterprise V2 Dynamic Expansion Rack (6 sidewall compartments) 93634EX
42U 1200mm Deep Dynamic Rack (6 sidewall compartments) 93604PX
42U 1200mm Deep Static Rack (6 sidewall compartments) 93614PX
42U Enterprise Rack (1105 mm deep; 4 sidewall compartments) 93084PX
42U Enterprise Expansion Rack (1105 mm deep; 4 sidewall compartments) 93084EX

For more information, see the list of Product Guides in the Rack cabinets category:
http://lenovopress.com/servers/options/racks?rt=product-guide

Power distribution units

The following table lists the power distribution units (PDUs) that are offered by Lenovo that can be used in RackSwitch G8124E solutions.

Table 14. Power distribution units
Description Part number
0U Basic PDUs
0U 36 C13/6 C19 24A/200-240V 1 Phase PDU with NEMA L6-30P line cord 00YJ776
0U 36 C13/6 C19 32A/200-240V 1 Phase PDU with IEC60309 332P6 line cord 00YJ777
0U 21 C13/12 C19 32A/200-240V/346-415V 3 Phase PDU with IEC60309 532P6 line cord 00YJ778
0U 21 C13/12 C19 48A/200-240V 3 Phase PDU with IEC60309 460P9 line cord 00YJ779
Switched and Monitored PDUs
0U 20 C13/4 C19 Switched and Monitored 24A/200-240V/1Ph PDU w/ NEMA L6-30P line cord 00YJ781
0U 20 C13/4 C19 Switched and Monitored 32A/200-240V/1Ph PDU w/ IEC60309 332P6 line cord 00YJ780
0U 18 C13/6 C19 Switched / Monitored 32A/200-240V/346-415V/3Ph PDU w/ IEC60309 532P6 cord 00YJ782
0U 12 C13/12 C19 Switched and Monitored 48A/200-240V/3Ph PDU w/ IEC60309 460P9 line cord 00YJ783
1U 9 C19/3 C13 Switched and Monitored DPI PDU (without line cord) 46M4002
1U 9 C19/3 C13 Switched and Monitored 60A 3Ph PDU with IEC 309 3P+Gnd cord 46M4003
1U 12 C13 Switched and Monitored DPI PDU (without line cord) 46M4004
1U 12 C13 Switched and Monitored 60A 3 Phase PDU with IEC 309 3P+Gnd line cord 46M4005
Ultra Density Enterprise PDUs (9x IEC 320 C13 + 3x IEC 320 C19 outlets)
Ultra Density Enterprise C19/C13 PDU Module (without line cord) 71762NX
Ultra Density Enterprise C19/C13 PDU 60A/208V/3ph with IEC 309 3P+Gnd line cord 71763NU
C13 Enterprise PDUs (12x IEC 320 C13 outlets)
DPI C13 Enterprise PDU+ (without line cord) 39M2816
DPI Single Phase C13 Enterprise PDU (without line cord) 39Y8941
C19 Enterprise PDUs (6x IEC 320 C19 outlets)
DPI Single Phase C19 Enterprise PDU (without line cord) 39Y8948
DPI 60A 3 Phase C19 Enterprise PDU with IEC 309 3P+G (208 V) fixed line cord 39Y8923
Front-end PDUs (3x IEC 320 C19 outlets)
DPI 30amp/125V Front-end PDU with NEMA L5-30P line cord 39Y8938
DPI 30amp/250V Front-end PDU with NEMA L6-30P line cord 39Y8939
DPI 32amp/250V Front-end PDU with IEC 309 2P+Gnd line cord 39Y8934
DPI 60amp/250V Front-end PDU with IEC 309 2P+Gnd line cord 39Y8940
DPI 63amp/250V Front-end PDU with IEC 309 2P+Gnd line cord 39Y8935
Universal PDUs (7x IEC 320 C13 outlets)
DPI Universal 7 C13 PDU (with 2 m IEC 320-C19 to C20 rack power cord) 00YE443
NEMA PDUs (6x NEMA 5-15R outlets)
DPI 100-127V PDU with fixed NEMA L5-15P line cord 39Y8905
Line cords for PDUs that ship without a line cord
DPI 30a Line Cord (NEMA L6-30P) 40K9614
DPI 32a Line Cord (IEC 309 P+N+G) 40K9612
DPI 32a Line Cord (IEC 309 3P+N+G) 40K9611
DPI 60a Cord (IEC 309 2P+G) 40K9615
DPI 63a Cord (IEC 309 P+N+G) 40K9613
DPI Australian/NZ 3112 Line Cord (32A) 40K9617
DPI Korean 8305 Line Cord (30A) 40K9618

For more information, see the list of Product Guides in the Power Distribution Units category:
http://lenovopress.com/servers/options/pdu

Uninterruptible power supply units

The following table lists the uninterruptible power supply (UPS) units that are offered by Lenovo that can be used in RackSwitch G8124E solutions.

Table 15. Uninterruptible power supply units
Description Part number
Worldwide models
RT1.5kVA 2U Rack or Tower UPS (100-125VAC) (8x NEMA 5-15R 12A outlets) 55941AX
RT1.5kVA 2U Rack or Tower UPS (200-240VAC) (8x IEC 320 C13 10A outlets) 55941KX
RT2.2kVA 2U Rack or Tower UPS (100-125VAC) (8x NEMA 5-20R 16A outlets) 55942AX
RT2.2kVA 2U Rack or Tower UPS (200-240VAC) (8x IEC 320 C13 10A, 1x IEC 320 C19 16A outlets) 55942KX
RT3kVA 2U Rack or Tower UPS (100-125VAC) (6x NEMA 5-20R 16A, 1x NEMA L5-30R 24A outlets) 55943AX
RT3kVA 2U Rack or Tower UPS (200-240VAC) (8x IEC 320 C13 10A, 1x IEC 320 C19 16A outlets) 55943KX
RT5kVA 3U Rack or Tower UPS (200-240VAC) (8x IEC 320 C13 10A, 2x IEC 320 C19 16A outlets) 55945KX
RT6kVA 3U Rack or Tower UPS (200-240VAC) (8x IEC 320 C13 10A, 2x IEC 320 C19 16A outlets) 55946KX
RT8kVA 6U Rack or Tower UPS (200-240VAC) (4x IEC 320-C19 16A outlets) 55948KX
RT11kVA 6U Rack or Tower UPS (200-240VAC) (4x IEC 320-C19 16A outlets) 55949KX
RT8kVA 6U 3:1 Phase Rack or Tower UPS (380-415VAC) (4x IEC 320-C19 16A outlets) 55948PX
RT11kVA 6U 3:1 Phase Rack or Tower UPS (380-415VAC) (4x IEC 320-C19 16A outlets) 55949PX
ASEAN, HTK, INDIA, and PRC models
ThinkSystem RT3kVA 2U Standard UPS (200-230VAC) (2x C13 10A, 2x GB 10A, 1x C19 16A outlets) 55943KT
ThinkSystem RT3kVA 2U Long Backup UPS (200-230VAC) (2x C13 10A, 2x GB 10A, 1x C19 16A outlets) 55943LT
ThinkSystem RT6kVA 5U UPS (200-230VAC) (2x C13 10A outlets, 1x Terminal Block output) 55946KT
ThinkSystem RT10kVA 5U UPS (200-230VAC) (2x C13 10A outlets, 1x Terminal Block output) 5594XKT

For more information, see the list of Product Guides in the Uninterruptible Power Supply Units category:
http://lenovopress.com/servers/options/ups#rt=product-guide

Lenovo Financial Services

Lenovo Financial Services reinforces Lenovo’s commitment to deliver pioneering products and services that are recognized for their quality, excellence, and trustworthiness. Lenovo Financial Services offers financing solutions and services that complement your technology solution anywhere in the world.

We are dedicated to delivering a positive finance experience for customers like you who want to maximize your purchase power by obtaining the technology you need today, protect against technology obsolescence, and preserve your capital for other uses.

We work with businesses, non-profit organizations, governments and educational institutions to finance their entire technology solution. We focus on making it easy to do business with us. Our highly experienced team of finance professionals operates in a work culture that emphasizes the importance of providing outstanding customer service. Our systems, processes and flexible policies support our goal of providing customers with a positive experience.

We finance your entire solution. Unlike others, we allow you to bundle everything you need from hardware and software to service contracts, installation costs, training fees, and sales tax. If you decide weeks or months later to add to your solution, we can consolidate everything into a single invoice.

Our Premier Client services provide large accounts with special handling services to ensure these complex transactions are serviced properly. As a premier client, you have a dedicated finance specialist who manages your account through its life, from first invoice through asset return or purchase. This specialist develops an in-depth understanding of your invoice and payment requirements. For you, this dedication provides a high-quality, easy, and positive financing experience.

For your region specific offers please ask your Lenovo sales representative or your technology provider about the use of Lenovo Financial Services. For more information, see the following Lenovo website:
http://www.lenovofs.com

Related product families

Product families related to this document are the following:

Trademarks

Lenovo and the Lenovo logo are trademarks or registered trademarks of Lenovo in the United States, other countries, or both. A current list of Lenovo trademarks is available on the Web at https://www.lenovo.com/us/en/legal/copytrade/.

The following terms are trademarks of Lenovo in the United States, other countries, or both:
Lenovo®
Flex System
Intelligent Cluster
Lenovo Services
NMotion®
NeXtScale
NeXtScale System®
RackSwitch
ThinkSystem®
VMready®
XClarity®

The following terms are trademarks of other companies:

Microsoft® and Hyper-V® are trademarks of Microsoft Corporation in the United States, other countries, or both.

Other company, product, or service names may be trademarks or service marks of others.