skip to main content

Lenovo ThinkSystem SR650 Server (Xeon SP Gen 1 / Gen 2)

Product Guide (withdrawn product)

Home
Top

Abstract

Lenovo ThinkSystem SR650 is an ideal 2-socket 2U rack server for small businesses up to large enterprises that need industry-leading reliability, management, and security, as well as maximizing performance and flexibility for future growth. The SR650 server is designed to handle a wide range of workloads, such as databases, virtualization and cloud computing, virtual desktop infrastructure (VDI), enterprise applications, collaboration/email, and business analytics and big data.

This product guide provides essential technical and pre-sales information on the SR650 server, its key features and specifications, components and options, and configuration guidelines.

This guide is intended for technical specialists, sales specialists, sales engineers, IT architects, and other IT professionals who want to learn more about the SR650 server and consider its use in IT solutions.

Change History

Changes in the June 17, 2024 update:

Walkthrough Video with David Watts and Russ Resnick

Introduction

Lenovo ThinkSystem SR650 is an ideal 2-socket 2U rack server for small businesses up to large enterprises that need industry-leading reliability, management, and security, as well as maximizing performance and flexibility for future growth. The SR650 server is designed to handle a wide range of workloads, such as databases, virtualization and cloud computing, virtual desktop infrastructure (VDI), enterprise applications, collaboration/email, and business analytics and big data.

Featuring the second generation of Intel Xeon Processor Scalable Family (Xeon SP Gen 2), the SR650 server offers scalable performance, storage capacity, and I/O expansion. The SR650 server supports up to two processors and up to 3 TB of memory, up to 24x 2.5-inch or 14x 3.5-inch drive bays with an extensive choice of drive technologies, and flexible I/O expansion options with a LOM slot, a dedicated storage controller slot, and up to 6x rear PCIe expansion slots.

The following figure shows the ThinkSystem SR650 with 2.5-inch hot-swap drives.

Lenovo ThinkSystem SR650
Figure 1. Lenovo ThinkSystem SR650 with 2.5-inch drive bays

Did you know?

The SR650 server offers onboard NVMe PCIe ports that allow direct connections to the U.2 NVMe PCIe SSDs, which frees up I/O slots and helps lower NVMe solution acquisition costs.

The SR650 server is designed to meet ASHRAE A4 standards (up to 45 °C, 113 °F) in select configurations, which enable customers to lower energy costs, while still maintaining world-class reliability.

The SR650 server delivers outstanding memory performance with Performance+ 2933 MHz DIMMs, which is achieved by supporting two-DIMMs-per-channel configurations at speeds up to 10% faster than the Intel specification defines, while still maintaining world-class reliability.

Key features

Combining performance and flexibility, the SR650 server is a great choice for small and medium businesses up to the large enterprise. It can provide outstanding uptime to keep business-critical applications and cloud deployments running safely. Ease of use and comprehensive systems management tools help make deployment easier. Outstanding reliability, availability, and serviceability (RAS) and high-efficiency design improve your business environment and help save operational costs.

Scalability and performance

The SR650 server offers numerous features to boost performance, improve scalability, and reduce costs:

  • Improves productivity by offering superior system performance with the second generation of the Intel Xeon Processor Scalable Family with up to 28-core processors, up to 38.5 MB of last level cache (LLC), up to 2933 MHz memory speeds, and up to 10.4 GT/s Ultra Path Interconnect (UPI) links.
    • Support for up to two processors, 56 cores, and 112 threads allows to maximize the concurrent execution of multithreaded applications.
    • Intelligent and adaptive system performance with energy efficient Intel Turbo Boost 2.0 Technology allows CPU cores to run at maximum speeds during peak workloads by temporarily going beyond processor thermal design power (TDP).
    • Intel Hyper-Threading Technology boosts performance for multithreaded applications by enabling simultaneous multithreading within each processor core, up to two threads per core.
    • Intel Virtualization Technology integrates hardware-level virtualization hooks that allow operating system vendors to better utilize the hardware for virtualization workloads.
    • Intel Speed Select Technology provides improvements in server utilization and guaranteed per-core performance service levels with more granular control over processor performance.
    • Intel Deep Learning Boost (Vector Neural Network Instruction set [VNNI]) is designed to deliver significant, more efficient Deep Learning (Inference) acceleration for high-performance Artificial Intelligence (AI) workloads.
    • Intel Advanced Vector Extensions 512 (AVX-512) enable acceleration of enterprise-class and high performance computing (HPC) workloads.
  • Helps maximize system performance for data intensive applications with up to 2933 MHz memory speeds and up to 3 TB of memory capacity with 3DS RDIMMs.
  • Boosts the performance of data-intensive applications and delivers consistent service levels at scale for virtualized and cloud environments by using the innovative persistent memory technology that provides a unique combination of affordable large memory capacity and non-volatility for up to 7.5 TB of total server memory capacity, including 3DS RDIMMs and DCPMMs (DC persistent memory modules).
  • Offers flexible and scalable internal storage in a 2U rack form factor with up to 24x 2.5-inch and 2x 3.5-inch drives for performance-optimized configurations or up to 14x 3.5-inch drives for capacity-optimized configurations, providing a wide selection of SAS/SATA HDD/SSD and PCIe NVMe SSD types and capacities.
  • Provides flexibility to use SAS, SATA, or NVMe PCIe drives in the same drive bays with an AnyBay design.
  • Provides I/O scalability with a LOM slot, PCIe 3.0 slot for an internal storage controller, and up to six PCI Express (PCIe) 3.0 I/O expansion slots in a 2U rack form factor.
  • Reduces I/O latency and increases overall system performance with Intel Integrated I/O Technology that embeds the PCI Express 3.0 controller into the Intel Xeon Processor Scalable Family.

Availability and serviceability

The SR650 server provides many features to simplify serviceability and increase system uptime:

  • Designed to run 24 hours a day, 7 days a week
  • Offers protection in the event of a non-correctable memory failure with Single Device Data Correction (SDDC, also known as Chipkill, requires x4-based DIMMs), Adaptive Double Device Data Correction (ADDDC, also known as Redundant Bit Steering [RBS], requires x4-based DIMMs and Intel Xeon Gold or Platinum processors), memory mirroring, and memory rank sparing.
  • Provides easy access to upgrades and serviceable parts (such as processors, memory DIMMs, and adapter cards) with tool-less cover removal.
  • Offers data protection and greater system uptime with hot-swap drives supporting basic or advanced RAID redundancy.
  • Provides availability for business-critical applications with redundant hot-swap power supplies and redundant hot-swap system fans.
  • Simplifies servicing, speeds up problem resolution, and helps improve system availability with light path diagnostics.
  • Allows preventive actions in advance of possible failure, thereby increasing server uptime and application availability with Proactive Platform Alerts (including PFA and SMART alerts) for processors, voltage regulators, memory, internal storage (SAS/SATA HDDs and SSDs, NVMe SSDs, M.2 storage, flash storage adapters), fans, power supplies, RAID controllers, and server ambient and sub-component temperatures.
  • Continuously monitors system parameters, triggers alerts, and performs recovery actions in case of failure to minimize downtime with Built-in XClarity Controller (XCC).
  • Provides quick access to system status, firmware, network, health, and alerts information via Virtual Operator Panel from the XClarity Mobile App running on the Android or iOS mobile device that is connected to the front USB port with XClarity Controller access.
  • Speeds up troubleshooting tasks to reduce service time with diagnostics built into the XClarity Provisioning Manager.

Manageability and security

Powerful systems management features simplify local and remote management of the SR650 server and deliver enterprise-class data protection:

  • Provides advanced service processor control, monitoring, and alerting functions with XClarity Controller, a next generation service processor.
  • Improves Unified Extensible Firmware Interface (UEFI) system setup, configuration, updates, simplified error handling, and operating system deployment with the embedded XClarity Provisioning Manager.
  • Offers XClarity Essentials software tools that can help you set up, use, and maintain the server.
  • Increases uptime, reduces costs, and improves productivity through advanced server management capabilities with Lenovo XClarity Administrator that provides comprehensive hardware management.
  • Provides on-the-go monitoring and management of devices in XClarity Administrator from anywhere with the Lenovo XClarity mobile app, which can help improve efficiency and reduce downtime risks.
  • Centralizes infrastructure resource management with Lenovo XClarity Integrators for VMware vCenter and Microsoft System Center, extending XClarity Administrator features to virtualization management software tools and enabling users to deploy and manage infrastructure end-to-end.
  • Offers advanced cryptographic functionality (such as digital signatures and remote attestation) with an integrated Trusted Platform Module (TPM) or optional Trusted Cryptographic Module (TCM) or Nationz TPM (available only in PRC).
  • Keeps user data safe with Lenovo Business Vantage, a security software tool suite designed to work with the Trusted Cryptographic Module (available only in PRC).
  • Offers enterprise-class data protection with advanced RAID and optional self-encrypting drives.
  • Provides faster, stronger encryption with industry-standard AES NI support.
  • Helps prevent certain classes of malicious buffer overflow attacks with Intel Execute Disable Bit functionality, when combined with a supporting operating system.
  • Enhances security through hardware-based resistance to malicious software attacks with Intel Trusted Execution Technology, allowing an application to run in its own isolated space, protected from all other software running on a system.

Energy efficiency

The SR650 server offers the following energy-efficiency features to save energy, reduce operational costs, increase energy availability, and contribute to the green environment:

  • Delivers impressive compute power per watt, featuring 80 PLUS Titanium and Platinum redundant power supplies.
  • Enables customers to lower energy costs with design to meet ASHRAE A4 standards in select configurations.
  • Reduces power drawn with Intel Intelligent Power Capability that powers individual processor elements on and off as needed.
  • Helps reduce power consumption with variable speed fans.
  • Helps achieve lower heat output and reduced cooling needs with Lenovo XClarity Energy Manager that provides advanced data center power notification, analysis, and policy-based management.

Components and connectors

The following figure shows the front of the SR650 server with up to 16x 2.5-inch drive bays.

Front view of the SR650: Up to 16x 2.5-inch drive bays
Figure 2. Front view of the SR650: Up to 16x 2.5-inch drive bays

The following figure shows the front of the SR650 server with up to 24x 2.5-inch drive bays.

Front view of the SR650: Up to 24x 2.5-inch drive bays
Figure 3. Front view of the SR650: Up to 24x 2.5-inch drive bays

The following figure shows the front of the SR650 server with 8x 3.5-inch drive bays.

Front view of the SR650: 8x 3.5-inch drive bays
Figure 4. Front view of the SR650: 8x 3.5-inch drive bays

The following figure shows the front of the SR650 server with 12x 3.5-inch drive bays.

Front view of the SR650: 12x 3.5-inch drive bays
Figure 5. Front view of the SR650: 12x 3.5-inch drive bays

The front of the SR650 server includes the following components:

  • Up to 16x 2.5-inch, or 24x 2.5-inch, or 8x 3.5-inch, or 12x 3.5-inch hot-swap drive bays.
  • One VGA port (optional).
  • One USB 3.0 port.
  • One USB 2.0 port with XClarity Controller access.
  • Power button.
  • Status LEDs.

The following figure shows the rear of the SR650 server.

Rear view of the SR650
Figure 6. Rear view of the SR650

The rear of the SR650 server includes the following components:

  • Up to six PCIe expansion slots (depending on the riser cards selected).
  • One LOM card slot.
  • One 1 GbE port for XClarity Controller.
  • One VGA port.
  • Two USB 3.0 ports.
  • Up to two hot-swap power supplies.

The following figure shows the locations of key components inside the SR650 server.

Internal view of the SR650
Figure 7. Internal view of the SR650

The following key components are located inside the SR650 server:

  • Up to two processors.
  • 24 DIMM slots (12 DIMM slots per processor).
  • Drive backplanes.
  • Two onboard NVMe PCIe connectors.
  • One M.2 module connector.
  • One LOM card connector.
  • Two onboard PCIe slots 4 and 7.
  • Two slots for PCIe riser cards.
  • One TCM connector.
  • Five (one processor) or six (two processors) hot-swap system fans.

Standard specifications

The following table lists the system specifications for the SR650 server.

Table 1. SR650 system specifications
Attribute Specification
Machine types 7X05 - 1 year warranty
7X06 - 3 year warranty
Form factor 2U rack-mount.
Processor Up to two 2nd Gen Intel Xeon Bronze, Silver, Gold, or Platinum processors:
  • Up to 28 cores (2.7 GHz core speeds).
  • Up to 3.9 GHz core speeds (8 cores).
  • UPI links up to 10.4 GT/s (2 UPI links used).
  • Up to 38.5 MB cache.
  • Up to 2933 MHz memory speed.

1st Gen Intel Xeon processors are also supported.

Chipset Intel C624.
Memory Up to 24 DIMM sockets (12 DIMMs per processor; six memory channels per processor with two DIMMs per channel). Support for RDIMMs, LRDIMMs (1st Gen processors only), or 3DS RDIMMs. Memory speed up to 2933 MHz depending on the processor selected. Memory types cannot be intermixed.
Persistent memory Up to 12x TruDDR4 2666 MHz DCPMMs in the DIMM slots. Not supported with 1st Gen Intel Xeon SP processors.
Memory protection
  • Processor's integrated memory controllers: Error correction code (ECC), SDDC (for x4-based memory DIMMs), ADDDC (for x4-based memory DIMMs, requires Intel Xeon Gold or Platinum processors), memory mirroring, memory rank sparing, patrol scrubbing, and demand scrubbing.
  • DCPMM's onboard memory controllers: ECC, SDDC, DDDC, patrol scrubbing, and demand scrubbing.
Note: In the configurations with DCPMMs, memory mirroring is supported only in the App Direct mode (other DCPMM modes do not support memory mirroring) and applies only to the RDIMMs or 3DS RDIMMs (DCPMMs are not mirrored). Memory sparing is not supported in the configurations with DCPMMs.
Memory capacity
  • Memory DIMMs only: Up to 3 TB with up to 24x 128 GB 3DS RDIMMs (Up to 1.5 TB per processor).
  • Memory DIMMs and persistent memory modules:
    • App Direct Mode: Up to 7.5 TB with up to 12x 128 GB 3DS RDIMMs and up to 12x 512 GB DCPMMs (Up to 3.75 TB per processor).
    • Memory Mode: Up to 6 TB with up to 12x 512 GB DCPMMs (Up to 3 TB per processor).
Note: Server configurations with more than 1 TB of memory capacity per socket (including DCPMMs and RDIMMs or 3DS RDIMMs) require processors that support up to 2 TB (M-suffix) or 4.5 TB (L-suffix) per socket. Server configurations with more than 2 TB of memory capacity per socket (including DCPMMs and RDIMMs or 3DS RDIMMs) require processors that support up to 4.5 TB per socket (L-suffix).
Drive bays
  • Up to 16 SFF (front) and 2 LFF (rear) hot-swap drive bays:
    • 8x 2.5" SAS/SATA + 8x 2.5" SAS/SATA + 2x 3.5" SAS/SATA
    • 4x 2.5" SAS/SATA & 4x 2.5" AnyBay + 8x 2.5" SAS/SATA + 2x 3.5" SAS/SATA
    • 4x 2.5" SAS/SATA & 4x 2.5" AnyBay + 4x 2.5" SAS/SATA & 4x 2.5" AnyBay + 2x 3.5" SAS/SATA
  • Up to 24 SFF (front) and 2 LFF (rear) hot-swap drive bays:
    • 8x 2.5" SAS/SATA + 8x 2.5" SAS/SATA + 8x 2.5" SAS/SATA + 2x 3.5" SAS/SATA
    • 4x 2.5" SAS/SATA & 4x 2.5" AnyBay + 8x 2.5" SAS/SATA + 8x 2.5" SAS/SATA + 2x 3.5" SAS/SATA
    • 4x 2.5" SAS/SATA & 4x 2.5" AnyBay + 4x 2.5" SAS/SATA & 4x 2.5" AnyBay + 8x 2.5" SAS/SATA + 2x 3.5" SAS/SATA
    • 4x 2.5" SAS/SATA & 4x 2.5" AnyBay + 4x 2.5" SAS/SATA & 4x 2.5" AnyBay + 4x 2.5" SAS/SATA & 4x 2.5" AnyBay
    • 16x 2.5" U.2 NVMe PCIe + 8x 2.5" SAS/SATA (factory-installed only)
    • 20x 2.5" U.2 NVMe PCIe
    • 24x 2.5" U.2 NVMe PCIe
  • Up to 10 LFF SAS/SATA hot-swap drive bays: 8x 3.5" (front) + 2x 3.5" (rear)
  • Up to 14 LFF hot-swap drive bays:
    • 12x 3.5" SAS/SATA (front) + 2x 3.5" SAS/SATA (rear)
    • 8x 3.5" SAS/SATA & 4x 3.5" AnyBay (front) + 2x 3.5" SAS/SATA (rear)
Internal storage capacity
  • 2.5-inch drives:
    • 737.28TB using 24x 30.72TB 2.5-inch SAS/SATA SSDs
    • 368.64TB using 24x 15.36TB 2.5-inch NVMe SSDs
    • 57.6TB using 24x 2.4TB 2.5-inch HDDs
  • 3.5-inch drives:
    • 280TB using 14x 20TB 3.5-inch HDDs
    • 215.04TB using 14x 15.36TB 3.5-inch SAS/SATA SSDs
    • 30.72TB using 4x 7.68TB 3.5-inch NVMe SSDs
Storage controller
  • 12 Gb SAS/SATA RAID adapters with up to 8GB flash-backed cache
  • 12 Gb SAS/SATA HBA (non-RAID)
  • Onboard PCIe NVMe (with Intel VROC NVMe RAID support for Intel SSDs and optionally non-Intel SSDs)
  • NVMe Switch Adapters (with Intel VROC NVMe RAID support for Intel SSDs and optionally non-Intel SSDs)
Optical drive bays None. Support for an external USB DVD RW Optical Disk Drive (See Optical drives).
Network interfaces
  • Onboard LOM slot for up to 4x 1/10 Gb Ethernet ports:
    • 2x or 4x 1 GbE RJ-45 ports (no 10/100 Mb support)
    • 2x or 4x 10 GbE RJ-45 ports (no 10/100 Mb support)
    • 2x or 4x 10 GbE SFP+ ports (no 10/100 Mb support)
  • Optional Mezzanine LOM (ML2) slot for dual-port 10 GbE cards with SFP+ or RJ-45 connectors or single- or dual-port 25 GbE cards with SFP28 connectors.
  • 1x RJ-45 10/100/1000 Mb Ethernet systems management port.
I/O expansion slots Up to seven slots. Slots 4 and 7 are the fixed slots on the system planar, and the remaining slots depend on the riser cards installed. The slots are as follows:
  • Slot 1: PCIe 3.0 x16 or PCIe 3.0 x8; full-height, half-length (PCIe x16 slot can be single- or double-wide)
  • Slot 2: PCIe 3.0 x8; full-height, half-length (not present if Slot 1 is PCIe x16 double-wide or Slot 3 is ML2 x16)
  • Slot 3: PCIe 3.0 x8, or PCIe 3.0 x16, or ML2 x8, or ML2 x16; full-height, half-length
  • Slot 4: PCIe 3.0 x8; low profile (vertical slot on system planar)
  • Slot 5: PCIe 3.0 x16; full-height, half-length
  • Slot 6: PCIe 3.0 x16; full-height, half-length
  • Slot 7: PCIe 3.0 x8 (for an internal storage controller)
Slots 5 and 6 require the second processor to be installed. Single-wide PCIe x16 Slot 1 requires the second processor to be installed.
Ports
  • Front: 1x USB 2.0 port with XClarity Controller access and 1x USB 3.0 port; optional 1x VGA port.
  • Rear: 2x USB 3.0 ports and 1x VGA port; optional 1x DB-9 serial port.
Cooling Five (one processor) or six (two processors) hot-swap single-rotor system fans with N+1 redundancy.
Power supply Up to two redundant hot-swap 550 W, 750 W, or 1100 W (100 - 240 V), or 1600 W (200 - 240 V) High Efficiency Platinum AC power supplies, or 750 W (200 - 240 V) High Efficiency Titanium AC power supplies. HVDC support (PRC only).
Video Matrox G200e with 16 MB memory integrated into the XClarity Controller. Maximum resolution is 1920x1200 at 60 Hz with 32 bits per pixel.
Hot-swap parts Drives, power supplies, and fans.
Systems management XClarity Controller (XCC) Standard, Advanced, or Enterprise (Pilot 4 chip), proactive platform alerts, light path diagnostics, XClarity Provisioning Manager, XClarity Essentials, XClarity Administrator, XClarity Integrators for VMware vCenter and Microsoft System Center, XClarity Energy Manager, Capacity Planner.
Security features Power-on password, administrator's password, secure firmware updates, Trusted Platform Module (TPM) 1.2 or 2.0 (configurable UEFI setting). Optional lockable front bezel. Optional Trusted Cryptographic Module (TCM) or Nationz TPM (available only in PRC). Optional Lenovo Business Vantage security software (available only in PRC).
Operating systems Microsoft Windows Server, Red Hat Enterprise Linux, SUSE Linux Enterprise Server, VMware ESXi. See the Operating systems section for specifics.
Warranty One-year (Machine Type 7X05) or three-year (Machine Type 7X06) customer-replaceable unit (CRU) and onsite limited warranty with 9x5 Next Business Day Parts Delivered.
Service and support Optional Lenovo Services upgrades: 2-hour or 4-hour response time, 6-hour or 24-hour committed service repair, warranty extension up to 5 years, 1-year or 2-year post-warranty extensions, YourDrive YourData, Enterprise Software Support, and Basic Hardware Installation Services.
Dimensions Width: 445 mm (17.5 in.), height: 87 mm (3.4 in.), depth: 764 mm (30.1 in.). See Physical specifications for details.
Weight Minimum configuration: 19 kg (41.9 lb), maximum: 32 kg (70.5 lb)

Models

ThinkSystem SR650 models can be configured by using the Lenovo Data Center Solution Configurator (DCSC).

Configure-to-order (CTO) models are used to create models with factory-integrated server customizations. For CTO models, two types of base CTO models are available for the SR650 as listed in the columns in the following table:

  • General purpose base CTO models are for general business (non-HPC) and is selectable by choosing General Purpose mode in DCSC.
  • AI and HPC base models are intended for Artificial Intelligence (AI) and High Performance Computing (HPC) configurations and solutions are enabled using the AI & HPC Hardware - ThinkSystem Hardware mode in DCSC. These configurations, along with Lenovo EveryScale Solutions, can also be built using System x and Cluster Solutions Configurator (x-config). Tip: Some HPC and AI models are not listed in DCSC and can only be configured in x-config.

Preconfigured server models may also be available for the SR650, however these are region-specific; that is, each region may define their own server models, and not all server models are available in every region.

The following table lists the base CTO models of the ThinkSystem SR650 server.

Table 2. Base CTO models
Machine Type/Model
General purpose
Machine Type/Model
for AI and HPC
Description
7X06CTO1WW 7X06CTOLWW ThinkSystem SR650 - 3yr Warranty
7X05CTO1WW 7X05CTOLWW ThinkSystem SR650 - 1yr Warranty

For CTO orders, the following table lists the base chassis feature codes for the server.

Table 3. Base chassis for CTO models
Feature code Description
BMN6 ThinkSystem SR650 2.5" Chassis with 8, 16 or 24 Bays v2
AUVV ThinkSystem SR650 2.5" Chassis with 8, 16 or 24 Bays
AUVW ThinkSystem SR650 3.5" Chassis with 8 or 12 Bays
BMNE ThinkSystem SR650 2.5" Chassis with 8 or 16 Bays v2
AUVX ThinkSystem SR650 2.5" Chassis with 8 or 16 Bays

The following tables list the available models, grouped by region.

Refer to the Specifications section for information about standard features of the server.

Common to all models:

  • All models indicated as having the 750W power supply are using the Platinum power supply

Models for Australia and New Zealand

Table 4. Models for Australia and New Zealand
Model Intel Xeon Scalable processor† Memory RAID Drive bays and drives LOM Slots Power
supply
Front
VGA
XCC Rail
kit
Standard models with a 3-year warranty (machine type 7X06)
7X06A0EHAU 1x Bronze 3204 6C 85W 1.9G 1x 16GB 2Rx8 2933 930-8i 8x 3.5" SAS/8, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0EKAU 1x Bronze 3204 6C 85W 1.9G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS/24, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0EJAU 1x Silver 4208 8C 85W 2.1G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS/24, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0ELAU 1x Silver 4208 8C 85W 2.1G 1x 16GB 2Rx8 2933 930-8i 8x 3.5" SAS/8, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0E2AU 1x Silver 4210 10C 85W 2.2G 1x 32GB 2933 530-8i 8x 2.5" SAS/24, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Ent Slide CMA
7X06A0EPAU 1x Silver 4210 10C 85W 2.2G 1x 16GB 2Rx8 2933 930-8i 8x 3.5" SAS/8, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0EUAU 1x Silver 4210 10C 85W 2.2G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS/24, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0ECAU 1x Silver 4214 12C 85W 2.2G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS/24, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0ESAU 1x Silver 4214 12C 85W 2.2G 1x 16GB 2Rx8 2933 930-8i 8x 3.5" SAS/8, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0E5AU 1x Silver 4215 8C 85W 2.5G 1x 32GB 2933 930-8i 8x 2.5" SAS/24, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Ent Slide CMA
7X06A0EFAU 1x Silver 4215 8C 85W 2.5G 1x 16GB 2Rx8 2933 930-8i 8x 3.5" SAS/8, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0ERAU 1x Silver 4215 8C 85W 2.5G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS/24, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0DYAU 1x Silver 4216 16C 100W 2.1G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS/24, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0E6AU 1x Silver 4216 16C 100W 2.1G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS/24, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Ent Slide CMA
7X06A0F0AU 1x Silver 4216 16C 100W 2.1G 1x 32GB 2933 930-8i 8x 2.5" SAS/24, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Ent Slide CMA
7X06A0F3AU 1x Silver 4216 16C 100W 2.1G 1x 16GB 2Rx8 2933 930-8i 8x 3.5" SAS/8, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0EDAU 1x Gold 5215 10C 85W 2.5G 1x 16GB 2Rx8 2933 930-8i 8x 3.5" SAS/8, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0EGAU 1x Gold 5215 10C 85W 2.5G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS/24, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0EYAU 1x Gold 5217 8C 115W 3.0G 1x 32GB 2933 930-8i 8x 2.5" SAS/24, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Ent Slide CMA
7X06A0F2AU 1x Gold 5217 8C 115W 3.0G 1x 16GB 2Rx8 2933 930-8i 8x 3.5" SAS/8, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0F8AU 1x Gold 5217 8C 115W 3.0G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS/24, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0EMAU 1x Gold 5218 16C 125W 2.3G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS/24, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0F4AU 1x Gold 5218 16C 125W 2.3G 1x 32GB 2933 930-8i 8x 2.5" SAS/24, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Ent Slide CMA
7X06A0F7AU 1x Gold 5218 16C 125W 2.3G 1x 16GB 2Rx8 2933 930-8i 8x 3.5" SAS/8, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0DZAU 1x Gold 5220 18C 125W 2.2G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS/24, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0EEAU 1x Gold 5220 18C 125W 2.2G 1x 16GB 2Rx8 2933 930-8i 8x 3.5" SAS/8, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0F5AU 1x Gold 6230 20C 125W 2.1G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS/24, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0F6AU 1x Gold 6230 20C 125W 2.1G 1x 16GB 2Rx8 2933 930-8i 8x 3.5" SAS/8, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0E1AU 1x Gold 6240 18C 150W 2.6G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS/24, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0F1AU 1x Gold 6240 18C 150W 2.6G 1x 16GB 2Rx8 2933 930-8i 8x 3.5" SAS/8, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0E7AU 1x Gold 6242 16C 150W 2.8G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS/24, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0EVAU 1x Gold 6242 16C 150W 2.8G 1x 16GB 2Rx8 2933 930-8i 8x 3.5" SAS/8, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0EQAU 1x Gold 6244 8C 150W 3.6G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS/24, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0E9AU 1x Gold 6248 20C 150W 2.5G 1x 16GB 2Rx8 2933 930-8i 8x 3.5" SAS/8, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0EAAU 1x Gold 6248 20C 150W 2.5G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS/24, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0E8AU 1x Gold 6252 24C 150W 2.1G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS/24, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0ENAU 1x Gold 6252 24C 150W 2.1G 1x 16GB 2Rx8 2933 930-8i 8x 3.5" SAS/8, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0EBAU 1x Gold 6254 18C 200W 3.1G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS/24, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
TopSeller models with a 3-year warranty (machine type 7X06)
7X06A0EWAU 1x Bronze 3204 6C 85W 1.9G 1x 16GB 2Rx8 2933 530-8i 8x 2.5" SAS/24, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Ent Slide CMA
7X06A0ETAU 1x Silver 4208 8C 85W 2.1G 1x 16GB 2Rx8 2933 530-8i 8x 2.5" SAS/24, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Ent Slide CMA
7X06A0EZAU 1x Silver 4208 8C 85W 2.1G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS/24, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Ent Slide CMA
7X06A0KBAU 1x Silver 4208 8C 85W 2.1G 1x 16GB 2Rx8 2666 930-8i 8x 3.5" SAS/8, Open bay Open 2x PCIe x8 1x 750W Yes Ent Slide CMA
7X06A0KCAU 1x Silver 4208 8C 85W 2.1G 1x 16GB 2Rx8 2666 930-16i 4GB 12x 3.5" SAS/12, Open bay Open 2x PCIe x8 1x 750W Yes Ent Slide CMA
7X06A0PLAU 1x Silver 4208 8C 85W 2.1G 1x 16GB 2Rx8 2933 Option Option 24x 2.5", Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Yes Ent Slide CMA
7X06A0Q0AU 1x Silver 4208 8C 85W 2.1G 1x 16GB 2Rx8 2933 9350-8i 8x 2.5" SAS/16, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Yes Ent Slide CMA
7X06A0E0AU 1x Silver 4210 10C 85W 2.2G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS/24, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Ent Slide CMA
7X06A0E3AU 1x Silver 4210 10C 85W 2.2G 1x 32GB 2933 930-8i 8x 2.5" SAS/24, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Ent Slide CMA
7X06A0EXAU 1x Silver 4210 10C 85W 2.2G 1x 16GB 2Rx8 2933 530-8i 8x 2.5" SAS/24, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Ent Slide CMA
7X06A0PMAU 1x Silver 4210 10C 85W 2.2G 1x 32GB 2933 Option Option 24x 2.5", Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Yes Ent Slide CMA
7X06A0Q1AU 1x Silver 4210 10C 85W 2.2G 1x 32GB 2933 9350-8i 8x 2.5" SAS/16, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Yes Ent Slide CMA
7X06A0K8AU 1x Silver 4214 12C 85W 2.2G 1x 16GB 2Rx8 2666 930-8i 8x 2.5" SAS/16, Open bay Open 2x PCIe x8 1x 750W Yes Ent Slide CMA
7X06A0E4AU 1x Silver 4215 8C 85W 2.5G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS/24, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Ent Slide CMA
7X06A0LUAU 1x Silver 4215R 8C 130W 3.2G 1x 32GB 2933 930-8i 8x 2.5" SAS/24, Open bay Open 2x PCIe x8 1x 750W Yes Ent Slide
7X06A0LTAU 1x Silver 4216 16C 100W 2.1G 1x 32GB 2933 930-8i 8x 2.5" SAS/24, Open bay Open 2x PCIe x8 1x 750W Yes Ent Slide
7X06A0LVAU 1x Gold 6226R 16C 150W 2.9G 1x 32GB 2933 930-8i 8x 2.5" SAS/24, Open bay Open 2x PCIe x8 1x 750W Yes Ent Slide
7X06A0LWAU 1x Gold 6226R 16C 150W 2.9G 1x 32GB 2933 Option Option 24x 2.5", Open bay Open 2x PCIe x8 1x 750W Yes Ent Slide
7X06A0LXAU 1x Gold 6226R 16C 150W 2.9G 1x 64GB 2933 Option Option 24x 2.5", Open bay Open 2x PCIe x8 1x 750W Yes Ent Slide
7X06A0PKAU 1x Gold 6226R 16C 150W 2.9G 1x 32GB 2933 Option Option 24x 2.5", Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Yes Ent Slide CMA
7X06A0PXAU 1x Gold 6226R 16C 150W 2.9G 1x 32GB 2933 9350-8i 8x 2.5" SAS/16, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Yes Ent Slide CMA

† Processor description: Processor model, number of cores, thermal design power (TDP), core frequency

Models for South East Asian countries (ASEAN)

Table 5. Models for South East Asian countries (ASEAN)
Model Intel Xeon Scalable processor† Memory RAID Drive bays and drives LOM Slots Power
supply
Front
VGA
XCC Rail
kit
TopSeller models with a 3-year warranty (machine type 7X06)
7X06A0BSSG 1x Bronze 3204 6C 85W 1.9G 1x 16GB 2Rx8 2933 930-8i 8x 3.5" SAS/8, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0D3SG 1x Bronze 3204 6C 85W 1.9G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS/24, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0CDSG 1x Silver 4208 8C 85W 2.1G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS/24, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0CESG 1x Silver 4208 8C 85W 2.1G 1x 16GB 2Rx8 2933 930-8i 8x 3.5" SAS/8, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0CTSG 1x Silver 4210 10C 85W 2.2G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS/24, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0DCSG 1x Silver 4210 10C 85W 2.2G 1x 16GB 2Rx8 2933 930-8i 8x 3.5" SAS/8, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0BRSG 1x Silver 4214 12C 85W 2.2G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS/24, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0D5SG 1x Silver 4214 12C 85W 2.2G 1x 16GB 2Rx8 2933 930-8i 8x 3.5" SAS/8, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0BVSG 1x Silver 4215 8C 85W 2.5G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS/24, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0DJSG 1x Silver 4215 8C 85W 2.5G 1x 16GB 2Rx8 2933 930-8i 8x 3.5" SAS/8, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0BNSG 1x Silver 4216 16C 100W 2.1G 1x 16GB 2Rx8 2933 930-8i 8x 3.5" SAS/8, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0CRSG 1x Silver 4216 16C 100W 2.1G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS/24, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0C7SG 1x Gold 5215 10C 85W 2.5G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS/24, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0D7SG 1x Gold 5215 10C 85W 2.5G 1x 16GB 2Rx8 2933 930-8i 8x 3.5" SAS/8, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0CUSG 1x Gold 5217 8C 115W 3.0G 1x 16GB 2Rx8 2933 930-8i 8x 3.5" SAS/8, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0D6SG 1x Gold 5217 8C 115W 3.0G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS/24, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0C8SG 1x Gold 5218 16C 125W 2.3G 1x 16GB 2Rx8 2933 930-8i 8x 3.5" SAS/8, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0DFSG 1x Gold 5218 16C 125W 2.3G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS/24, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0BYSG 1x Gold 5220 18C 125W 2.2G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS/24, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0C0SG 1x Gold 5220 18C 125W 2.2G 1x 16GB 2Rx8 2933 930-8i 8x 3.5" SAS/8, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0DASG 1x Gold 6230 20C 125W 2.1G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS/24, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0DESG 1x Gold 6230 20C 125W 2.1G 1x 16GB 2Rx8 2933 930-8i 8x 3.5" SAS/8, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0BXSG 1x Gold 6240 18C 150W 2.6G 1x 16GB 2Rx8 2933 930-8i 8x 3.5" SAS/8, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0DNSG 1x Gold 6240 18C 150W 2.6G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS/24, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0BHSG 1x Gold 6242 16C 150W 2.8G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS/24, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0D9SG 1x Gold 6242 16C 150W 2.8G 1x 16GB 2Rx8 2933 930-8i 8x 3.5" SAS/8, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0C4SG 1x Gold 6244 8C 150W 3.6G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS/24, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0BDSG 1x Gold 6248 20C 150W 2.5G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS/24, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0CMSG 1x Gold 6248 20C 150W 2.5G 1x 16GB 2Rx8 2933 930-8i 8x 3.5" SAS/8, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0BTSG 1x Gold 6252 24C 150W 2.1G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS/24, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0DMSG 1x Gold 6252 24C 150W 2.1G 1x 16GB 2Rx8 2933 930-8i 8x 3.5" SAS/8, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0BMSG 1x Gold 6254 18C 200W 3.1G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS/24, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt

† Processor description: Processor model, number of cores, thermal design power (TDP), core frequency

Models for Brazil

Table 6. Models for Brazil
Model Intel Xeon Scalable processor† Memory RAID Drive bays and drives LOM Slots Power
supply
Front
VGA
XCC Rail
kit
Standard models with a 3-year warranty (machine type 7X06)
7X06A0HCBR 1x Silver 4210 10C 85W 2.2G 1x 32GB 2933 730-8i 2GB 8x 2.5" SAS/24, Open bay 4x1Gb 5x PCIe x8 1x 750W Yes Std Slide
7X06A0HFBR 1x Gold 5220 18C 125W 2.2G 1x 32GB 2933 730-8i 2GB 8x 2.5" SAS/24, Open bay 4x1Gb 5x PCIe x8 1x 1100W Yes Std Slide
7X06A0QGBR 2x Gold 6226R 16C 150W 2.9G 16x 128GB 2933 930-16i 4GB 16x 2.5" SAS/24, 2x 400GB 3732+ 8x 1.92TB PM893, 2x 32GB M.2 2x1Gb 3x PCIe x8, 2x PCIe x16 2x 1100W Opt Ent Slide
7X06A0QDBR 2x Gold 6238L 22C 140W 2.1G 8x 128GB 2933 930-16i 4GB 16x 2.5" SAS/24, 2x 400GB 3732+ 4x 1.92TB PM893, 2x 32GB M.2 2x1Gb 3x PCIe x8, 2x PCIe x16 2x 750W Opt Ent Slide
7X06A0J4BR 2x Platinum 8276M 28C 165W 2.2G 24x 128GB 2933 930-24i 8xAny+ 16xSAS 2.5"/24, 16x 960GB S4610 4x1Gb 2x PCIe x8, 2x PCIe x16 2x 1100W Opt Ent Slide CMA
TopSeller models with a 3-year warranty (machine type 7X06)
7X06100RBR 1x Bronze 3204 6C 85W 1.9G 1x 16GB 2Rx8 2666 530-8i 8x 3.5" SAS/8, Open bay 4x1Gb 5x PCIe x8 1x 550W Opt Std Slide
7X06A0N4BR 1x Bronze 3204 6C 85W 1.9G 1x 32GB 2933 730-8i 2GB 8x 3.5" SAS/8, 2x 4TB SATA HDD 4x1Gb 5x PCIe x8 2x 750W Yes Std Slide
7X06A0N0BR 1x Silver 4208 8C 85W 2.1G 1x 32GB 2933 730-8i 2GB 8x 3.5" SAS/8, 2x 4TB SATA HDD 4x1Gb 5x PCIe x8 2x 750W Yes Std Slide
7X06100VBR 1x Silver 4210 10C 85W 2.2G 1x 32GB 2933 730-8i 2GB 8x 2.5" SAS/16, Open bay 4x1Gb 3x PCIe x8, 1x PCIe x16 2x 750W Yes Std Slide
7X06A0HKBR 1x Silver 4210 10C 85W 2.2G 1x 32GB 2666 730-8i 2GB 8x 2.5" SAS/16, Open bay 4x1Gb 3x PCIe x8, 1x PCIe x16 1x 750W Yes Std Slide
7X06A0KDBR 1x Silver 4210 10C 85W 2.2G 1x 32GB 2933 730-8i 2GB 8x 2.5" SAS/16, Open bay 4x1Gb 3x PCIe x8, 1x PCIe x16 2x 750W Yes Ent Slide
7X06A0KGBR 1x Silver 4210 10C 85W 2.2G 1x 32GB 2933 730-8i 2GB 8x 2.5" SAS/16, Open bay Open 3x PCIe x8, 1x PCIe x16 2x 750W Yes Std Slide
7X06A0L2BR 1x Silver 4210R 10C 100W 2.4G 1x 32GB 2933 730-8i 2GB 8x 2.5" SAS/16, Open bay 4x1Gb 3x PCIe x8, 1x PCIe x16 2x 750W Yes Std Slide
7X06A0L3BR 1x Silver 4210R 10C 100W 2.4G 1x 32GB 2933 730-8i 2GB 8x 2.5" SAS/16, Open bay 4x1Gb 3x PCIe x8, 1x PCIe x16 2x 750W Yes Ent Slide
7X06A0M8BR 1x Silver 4210R 10C 100W 2.4G 1x 32GB 2933 730-8i 2GB 8x 3.5" SAS/8, Open bay 4x1Gb 5x PCIe x8 2x 750W Opt Std Slide
7X06A0MABR 1x Silver 4210R 10C 100W 2.4G 1x 32GB 2933 730-8i 2GB 8x 3.5" SAS/8, 1x 2TB SATA HDD 4x1Gb 5x PCIe x8 2x 750W Opt Std Slide
7X06A0N5BR 1x Silver 4210R 10C 100W 2.4G 1x 32GB 2933 730-8i 2GB 8x 3.5" SAS/8, 2x 4TB SATA HDD 4x1Gb 5x PCIe x8 2x 750W Yes Std Slide
7X06100WBR 1x Silver 4214 12C 85W 2.2G 1x 32GB 2933 730-8i 2GB 8x 2.5" SAS/16, Open bay 4x1Gb 3x PCIe x8, 1x PCIe x16 2x 750W Yes Std Slide
7X06A0HDBR 1x Silver 4214 12C 85W 2.2G 1x 32GB 2933 730-8i 2GB 8x 2.5" SAS/24, Open bay 4x1Gb 5x PCIe x8 1x 750W Yes Std Slide
7X06A0HJBR 1x Silver 4214 12C 85W 2.2G 1x 32GB 2666 730-8i 2GB 8x 2.5" SAS/16, Open bay 4x1Gb 3x PCIe x8, 1x PCIe x16 1x 750W Yes Std Slide
7X06A0KFBR 1x Silver 4214 12C 85W 2.2G 1x 32GB 2933 730-8i 2GB 8x 2.5" SAS/16, Open bay Open 3x PCIe x8, 1x PCIe x16 2x 750W Yes Std Slide
7X06A0L1BR 1x Silver 4214R 12C 100W 2.4G 1x 32GB 2933 730-8i 2GB 8x 2.5" SAS/16, Open bay 4x1Gb 3x PCIe x8, 1x PCIe x16 2x 750W Yes Std Slide
7X06A0M5BR 1x Silver 4214R 12C 100W 2.4G 1x 32GB 2933 730-8i 2GB 8x 3.5" SAS/8, Open bay 4x1Gb 5x PCIe x8 2x 750W Opt Std Slide
7X06A0M7BR 1x Silver 4214R 12C 100W 2.4G 1x 32GB 2933 730-8i 2GB 8x 3.5" SAS/8, 1x 2TB SATA HDD 4x1Gb 5x PCIe x8 2x 750W Opt Std Slide
7X06A0HEBR 1x Silver 4216 16C 100W 2.1G 1x 32GB 2933 730-8i 2GB 8x 2.5" SAS/24, Open bay 4x1Gb 5x PCIe x8 1x 750W Yes Std Slide
7X06A0HUBR 1x Gold 5218 16C 125W 2.3G 1x 32GB 2933 730-8i 2GB 8x 2.5" SAS/16, Open bay 4x1Gb 2x PCIe x8 2x 750W Yes Std Slide
7X06A0HVBR 2x Gold 5218 16C 125W 2.3G 2x 32GB 2933 730-8i 2GB 8x 2.5" SAS/16, Open bay 4x1Gb 2x PCIe x8 2x 750W Yes Std Slide
7X06A0MVBR 1x Gold 5218R 20C 125W 2.1G 1x 32GB 2933 930-16i 4GB 8x 2.5" SAS/16, Open bay 2x10Gb RJ45 5x PCIe x8 2x 750W Yes Ent Slide
7X06A0MXBR 1x Gold 5218R 20C 125W 2.1G 1x 32GB 2933 930-16i 4GB 8x 2.5" SAS/16, Open bay 2x10Gb RJ45 5x PCIe x8 2x 750W Yes Ent Slide
7X06A0MUBR 1x Gold 6240R 24C 165W 2.4G 2x 32GB 2933 930-16i 4GB 16x 2.5" SAS/16, Open bay 4x10Gb RJ45 5x PCIe x8 2x 1100W Yes Ent Slide
7X06A0MWBR 1x Gold 6240R 24C 165W 2.4G 2x 32GB 2933 930-16i 4GB 16x 2.5" SAS/16, Open bay 4x10Gb RJ45 5x PCIe x8 2x 1100W Yes Ent Slide

† Processor description: Processor model, number of cores, thermal design power (TDP), core frequency

Models for EMEA region

Table 7. Models for EMEA region
Model Intel Xeon Scalable processor† Memory RAID Drive bays and drives LOM Slots & GPUs Power
supply
Front
VGA
XCC Rail
kit
Standard models with a 3-year warranty (machine type 7X06)
7X061012EA 1x Silver 4208 8C 85W 2.1G 2x 32GB 2933 930-8i 8x 2.5" SAS/24, 2x 480GB MV SSD 4x1Gb 5x PCIe x8 2x 750W Opt Ent Slide
7X061014EA 1x Silver 4208 8C 85W 2.1G 1x 32GB 2933 9350-8i 8x 2.5" SAS/24, Open bay Open 2x PCIe x8 1x 750W Opt Ent Slide
7X06A0ATEA 1x Silver 4208 8C 85W 2.1G 1x 16GB 2Rx8 2666 930-16i 4GB 12x 3.5" SAS/12, Open bay Open 2x PCIe x8 1x 1100W Opt Ent Slide
7X06A0AWEA 1x Silver 4208 8C 85W 2.1G 1x 16GB 2Rx8 2666 Option Option 24x 2.5", Open bay Open 2x PCIe x8 1x 750W Opt Ent Slide
7X06A0H5EA 1x Silver 4208 8C 85W 2.1G 1x 32GB 2933 930-8i 8x 2.5" SAS/24, 2x 480GB PM883 Open 2x PCIe x8 1x 750W Opt Ent Slide
7X06A0HSEA 1x Silver 4208 8C 85W 2.1G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS/24, Open bay Open 2x PCIe x8 1x 750W Opt Ent Slide
7X06A0JPEA 1x Silver 4208 8C 85W 2.1G 1x 32GB 2933 Option Option 24x 2.5", Open bay Open 2x PCIe x8 1x 750W Opt Ent Slide
7X06A0K9EA 1x Silver 4208 8C 85W 2.1G 1x 32GB 2933 930-8i 8x 2.5" SAS/24, Open bay Open 2x PCIe x8 1x 750W Opt Ent Slide
7X06A0KAEA 1x Silver 4208 8C 85W 2.1G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS/24, Open bay Open 2x PCIe x8 1x 750W Opt Ent Slide
7X06A0MJEA 1x Silver 4208 8C 85W 2.1G 1x 32GB 2933 940-8i 4GB 8x 2.5" SAS/24, Open bay Open 2x PCIe x8 1x 750W Opt Ent Slide
7X06A0MQEA 1x Silver 4208 8C 85W 2.1G 1x 32GB 2933 940-8i 4GB 8x 3.5" SAS/8, Open bay Open 2x PCIe x8 1x 750W Opt Ent Slide
7X06A0MREA 1x Silver 4208 8C 85W 2.1G 1x 32GB 2933 940-16i 4GB 12x 3.5" SAS/12, Open bay Open 2x PCIe x8 1x 1100W Opt Ent Slide
7X06A0NLEA 1x Silver 4208 8C 85W 2.1G 1x 32GB 2933 940-8i 4GB 8x 2.5" SAS/24, Open bay Open 2x PCIe x8 1x 750W Opt Ent Slide
7X06A0P1EA 1x Silver 4208 8C 85W 2.1G 1x 32GB 2933 9350-8i 8x 2.5" SAS/24, Open bay Open 2x PCIe x8 1x 750W Opt Ent Slide
7X06A0P2EA 1x Silver 4208 8C 85W 2.1G 1x 32GB 2933 9350-8i 8x 2.5" SAS/24, Open bay Open 2x PCIe x8 2x 750W Opt Ent Slide
7X06A0P5EA 1x Silver 4208 8C 85W 2.1G 1x 32GB 2933 940-8i 4GB 8x 2.5" SAS/24, Open bay Open 2x PCIe x8 2x 750W Opt Ent Slide
7X06A0P6EA 1x Silver 4208 8C 85W 2.1G 1x 32GB 2933 940-16i 4GB 12x 3.5" SAS/12, Open bay Open 2x PCIe x8 1x 1100W Opt Ent Slide
7X06A0PFEA 1x Silver 4208 8C 85W 2.1G 1x 32GB 2933 9350-16i 8xSAS+ 4xAny 3.5"/12, Open bay Open 2x PCIe x8 1x 1100W Opt Ent Slide
7X06A0PPEA 1x Silver 4208 8C 85W 2.1G 1x 32GB 2933 940-8i 4GB 8x 2.5" SAS/24, Open bay Open 2x PCIe x8 1x 750W Opt Ent Slide
7X06A0PREA 1x Silver 4208 8C 85W 2.1G 1x 32GB 2933 940-8i 4GB 8x 2.5" SAS/24, Open bay Open 2x PCIe x8 1x 750W Titanium Opt Ent Slide
7X06A0PVEA 1x Silver 4208 8C 85W 2.1G 1x 32GB 2933 9350-8i 8x 2.5" SAS/24, Open bay Open 2x PCIe x8 1x 750W Titanium Opt Ent Slide
7X06A0PZEA 1x Silver 4208 8C 85W 2.1G 1x 32GB 2933 Option Option 24x 2.5", Open bay Open 2x PCIe x8 1x 750W Titanium Opt Ent Slide
7X06A0Q9EA 1x Silver 4208 8C 85W 2.1G 1x 64GB 2933 Option Option 24x 2.5", Open bay Open 2x PCIe x8 1x 750W Titanium Opt Ent Slide
7X06A0QAEA 1x Silver 4208 8C 85W 2.1G 1x 64GB 2933 9350-8i 8x 2.5" SAS/24, Open bay Open 2x PCIe x8 1x 750W Titanium Opt Ent Slide
7X06A0QVEA 1x Silver 4208 8C 85W 2.1G 1x 32GB 2933 530-8i 8x 2.5" SAS/24, Open bay Open 2x PCIe x8 1x 750W Titanium Opt Ent Slide
7X06A0QWEA 1x Silver 4208 8C 85W 2.1G 1x 32GB 2933 930-8i 8x 2.5" SAS/24, Open bay Open 2x PCIe x8 1x 750W Titanium Opt Ent Slide
7X06A0R2EA 1x Silver 4208 8C 85W 2.1G 1x 32GB 2933 930-16i 4GB 12x 3.5" SAS/12, Open bay Open 2x PCIe x8 1x 1100W Opt Ent Slide
7X06A0R5EA 1x Silver 4208 8C 85W 2.1G 1x 32GB 2933 930-8i 8x 3.5" SAS/8, Open bay Open 2x PCIe x8 1x 750W Titanium Opt Ent Slide
7X06A0R6EA 1x Silver 4208 8C 85W 2.1G 1x 32GB 2933 530-8i 8x 3.5" SAS/8, Open bay Open 2x PCIe x8 1x 750W Titanium Opt Ent Slide
7X06101EEA 1x Silver 4210 10C 85W 2.2G 1x 32GB 2933 Option Option 24x 2.5", Open bay Open 2x PCIe x8 1x 750W Titanium Opt Ent Slide
7X06A0B0EA 1x Silver 4210 10C 85W 2.2G 1x 32GB 2666 930-8i 8x 2.5" SAS/24, Open bay Open 2x PCIe x8 2x 750W Opt Ent Slide
7X06A0B3EA 1x Silver 4210 10C 85W 2.2G 1x 16GB 2Rx8 2666 Option Option 24x 2.5", Open bay Open 2x PCIe x8 1x 750W Opt Ent Slide
7X06A0B4EA 1x Silver 4210 10C 85W 2.2G 1x 16GB 2Rx8 2666 930-8i 8x 2.5" SAS/24, Open bay Open 2x PCIe x8 1x 750W Opt Ent Slide
7X06A0B7EA 1x Silver 4210 10C 85W 2.2G 1x 16GB 2Rx8 2666 930-8i 8x 3.5" SAS/8, Open bay Open 2x PCIe x8 1x 750W Opt Ent Slide
7X06A0H7EA 1x Silver 4210 10C 85W 2.2G 1x 32GB 2933 930-8i 8x 2.5" SAS/24, 2x 480GB PM883 Open 2x PCIe x8 1x 750W Opt Ent Slide
7X06A0HTEA 1x Silver 4210 10C 85W 2.2G 1x 32GB 2933 930-8i 8x 2.5" SAS/24, Open bay Open 2x PCIe x8 1x 750W Opt Ent Slide
7X061013EA 1x Silver 4210R 10C 100W 2.4G 2x 32GB 2933 930-8i 8x 2.5" SAS/24, 2x 480GB MV SSD 4x1Gb 5x PCIe x8 2x 750W Opt Ent Slide
7X061015EA 1x Silver 4210R 10C 100W 2.4G 1x 32GB 2933 9350-8i 8x 2.5" SAS/24, Open bay Open 2x PCIe x8 1x 750W Opt Ent Slide
7X06A0JSEA 1x Silver 4210R 10C 100W 2.4G 1x 32GB 2933 Option Option 24x 2.5", Open bay Open 2x PCIe x8 1x 750W Opt Ent Slide
7X06A0JXEA 1x Silver 4210R 10C 100W 2.4G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS/24, Open bay Open 2x PCIe x8 1x 750W Opt Ent Slide
7X06A0JYEA 1x Silver 4210R 10C 100W 2.4G 1x 32GB 2933 930-8i 8x 2.5" SAS/24, Open bay Open 2x PCIe x8 2x 750W Opt Ent Slide
7X06A0JZEA 1x Silver 4210R 10C 100W 2.4G 1x 32GB 2933 930-8i 8x 3.5" SAS/8, Open bay Open 2x PCIe x8 1x 750W Opt Ent Slide
7X06A0MDEA 1x Silver 4210R 10C 100W 2.4G 1x 32GB 2933 940-8i 4GB 8x 2.5" SAS/24, Open bay Open 2x PCIe x8 1x 750W Opt Ent Slide
7X06A0MMEA 1x Silver 4210R 10C 100W 2.4G 1x 32GB 2933 940-8i 4GB 8x 2.5" SAS/24, Open bay Open 2x PCIe x8 2x 750W Opt Ent Slide
7X06A0MPEA 1x Silver 4210R 10C 100W 2.4G 1x 32GB 2933 940-8i 4GB 8x 3.5" SAS/8, Open bay Open 2x PCIe x8 1x 750W Opt Ent Slide
7X06A0MSEA 1x Silver 4210R 10C 100W 2.4G 1x 32GB 2933 940-16i 4GB 12x 3.5" SAS/12, Open bay Open 2x PCIe x8 1x 1100W Opt Ent Slide
7X06A0NMEA 1x Silver 4210R 10C 100W 2.4G 1x 32GB 2933 940-8i 4GB 8x 2.5" SAS/24, Open bay Open 2x PCIe x8 1x 750W Opt Ent Slide
7X06A0P0EA 1x Silver 4210R 10C 100W 2.4G 1x 32GB 2933 9350-8i 8x 2.5" SAS/24, Open bay Open 2x PCIe x8 1x 750W Opt Ent Slide
7X06A0P3EA 1x Silver 4210R 10C 100W 2.4G 1x 32GB 2933 9350-8i 8x 2.5" SAS/24, Open bay Open 2x PCIe x8 2x 750W Opt Ent Slide
7X06A0P4EA 1x Silver 4210R 10C 100W 2.4G 1x 32GB 2933 940-8i 4GB 8x 2.5" SAS/24, Open bay Open 2x PCIe x8 2x 750W Opt Ent Slide
7X06A0PAEA 1x Silver 4210R 10C 100W 2.4G 1x 32GB 2933 9350-8i 8x 3.5" SAS/8, Open bay Open 2x PCIe x8 1x 750W Opt Ent Slide
7X06A0PDEA 1x Silver 4210R 10C 100W 2.4G 1x 32GB 2933 940-8i 4GB 8x 3.5" SAS/8, Open bay Open 2x PCIe x8 1x 750W Opt Ent Slide
7X06A0PQEA 1x Silver 4210R 10C 100W 2.4G 1x 32GB 2933 940-8i 4GB 8x 2.5" SAS/24, Open bay Open 2x PCIe x8 1x 750W Opt Ent Slide
7X06A0PSEA 1x Silver 4210R 10C 100W 2.4G 1x 32GB 2933 9350-8i 8x 2.5" SAS/24, Open bay Open 2x PCIe x8 1x 750W Titanium Opt Ent Slide
7X06A0PUEA 1x Silver 4210R 10C 100W 2.4G 1x 32GB 2933 940-8i 4GB 8x 2.5" SAS/24, Open bay Open 2x PCIe x8 1x 750W Titanium Opt Ent Slide
7X06A0Q6EA 1x Silver 4210R 10C 100W 2.4G 1x 64GB 2933 9350-8i 8x 2.5" SAS/24, Open bay Open 2x PCIe x8 1x 750W Titanium Opt Ent Slide
7X06A0Q7EA 1x Silver 4210R 10C 100W 2.4G 1x 64GB 2933 Option Option 24x 2.5", Open bay Open 2x PCIe x8 1x 750W Titanium Opt Ent Slide
7X06A0QUEA 1x Silver 4210R 10C 100W 2.4G 1x 32GB 2933 530-8i 8x 2.5" SAS/24, Open bay Open 2x PCIe x8 1x 750W Titanium Opt Ent Slide
7X06A0QXEA 1x Silver 4210R 10C 100W 2.4G 1x 32GB 2933 930-8i 8x 2.5" SAS/24, Open bay Open 2x PCIe x8 1x 750W Titanium Opt Ent Slide
7X06A0R3EA 1x Silver 4210R 10C 100W 2.4G 1x 32GB 2933 930-16i 4GB 12x 3.5" SAS/12, Open bay Open 2x PCIe x8 1x 1100W Opt Ent Slide
7X06A0R4EA 1x Silver 4210R 10C 100W 2.4G 1x 32GB 2933 930-8i 8x 3.5" SAS/8, Open bay Open 2x PCIe x8 1x 750W Titanium Opt Ent Slide
7X06A0AVEA 1x Silver 4214 12C 85W 2.2G 1x 32GB 2666 930-8i 8x 2.5" SAS/24, Open bay Open 2x PCIe x8 2x 750W Opt Ent Slide
7X06A0AZEA 1x Silver 4214 12C 85W 2.2G 1x 32GB 2666 930-16i 4GB 12x 3.5" SAS/12, Open bay Open 2x PCIe x8 1x 1100W Opt Ent Slide
7X06A0B2EA 1x Silver 4214 12C 85W 2.2G 1x 32GB 2666 930-16i 4GB 8x 2.5" SAS/24, Open bay Open 2x PCIe x8 1x 750W Opt Ent Slide
7X06A0B9EA 1x Silver 4214 12C 85W 2.2G 1x 16GB 2Rx8 2666 Option Option 24x 2.5", Open bay Open 2x PCIe x8 1x 750W Opt Ent Slide
7X06A0MYEA 2x Silver 4214 12C 85W 2.2G 6x 32GB 2933 930-16i 8GB 12x 3.5" SAS/12, 2x 3.2TB PM1645a, 2x 128GB M.2 4x1Gb 2x PCIe x8, 2x PCIe x16 2x 750W Opt Ent Slide
7X06A0JREA 1x Silver 4214R 12C 100W 2.4G 1x 32GB 2933 930-8i 8x 2.5" SAS/24, Open bay Open 2x PCIe x8 2x 750W Opt Ent Slide
7X06A0K1EA 1x Silver 4214R 12C 100W 2.4G 1x 32GB 2933 Option Option 24x 2.5", Open bay Open 2x PCIe x8 1x 750W Opt Ent Slide
7X06A0MEEA 1x Silver 4214R 12C 100W 2.4G 1x 32GB 2933 940-8i 4GB 8x 2.5" SAS/24, Open bay Open 2x PCIe x8 1x 750W Opt Ent Slide
7X06A0MNEA 1x Silver 4214R 12C 100W 2.4G 1x 32GB 2933 940-8i 4GB 8x 2.5" SAS/24, Open bay Open 2x PCIe x8 2x 750W Opt Ent Slide
7X06A0NNEA 1x Silver 4214R 12C 100W 2.4G 1x 32GB 2933 940-8i 4GB 8x 2.5" SAS/24, Open bay Open 2x PCIe x8 1x 750W Opt Ent Slide
7X06A0NZEA 1x Silver 4214R 12C 100W 2.4G 1x 32GB 2933 9350-8i 8x 2.5" SAS/24, Open bay Open 2x PCIe x8 1x 750W Opt Ent Slide
7X06A0QYEA 1x Silver 4214R 12C 100W 2.4G 1x 32GB 2933 930-8i 8x 2.5" SAS/24, Open bay Open 2x PCIe x8 1x 750W Titanium Opt Ent Slide
7X06A0AREA 1x Silver 4215 8C 85W 2.5G 1x 16GB 2Rx8 2666 Option Option 24x 2.5", Open bay Open 2x PCIe x8 1x 750W Opt Ent Slide
7X06A0MKEA 1x Silver 4215 8C 85W 2.5G 1x 32GB 2933 940-8i 4GB 8x 2.5" SAS/24, Open bay Open 2x PCIe x8 1x 750W Opt Ent Slide
7X06A0NPEA 1x Silver 4215 8C 85W 2.5G 1x 32GB 2933 940-8i 4GB 8x 2.5" SAS/24, Open bay Open 2x PCIe x8 1x 750W Opt Ent Slide
7X06A0NYEA 1x Silver 4215 8C 85W 2.5G 1x 32GB 2933 9350-8i 8x 2.5" SAS/24, Open bay Open 2x PCIe x8 1x 750W Opt Ent Slide
7X06A0P7EA 1x Silver 4215 8C 85W 2.5G 1x 32GB 2933 940-16i 4GB 12x 3.5" SAS/12, Open bay Open 2x PCIe x8 1x 1100W Opt Ent Slide
7X06A0PBEA 1x Silver 4215 8C 85W 2.5G 1x 32GB 2933 9350-8i 8x 3.5" SAS/8, Open bay Open 2x PCIe x8 1x 750W Opt Ent Slide
7X06A0PCEA 1x Silver 4215 8C 85W 2.5G 1x 32GB 2933 940-8i 4GB 8x 3.5" SAS/8, Open bay Open 2x PCIe x8 1x 750W Opt Ent Slide
7X06A0PGEA 1x Silver 4215 8C 85W 2.5G 1x 32GB 2933 9350-16i 8xSAS+ 4xAny 3.5"/12, Open bay Open 2x PCIe x8 1x 1100W Opt Ent Slide
7X06A0Q8EA 1x Silver 4215 8C 85W 2.5G 1x 64GB 2933 Option Option 24x 2.5", Open bay Open 2x PCIe x8 1x 750W Titanium Opt Ent Slide
7X06A0QFEA 1x Silver 4215 8C 85W 2.5G 1x 64GB 2933 9350-8i 8x 2.5" SAS/24, Open bay Open 2x PCIe x8 1x 750W Titanium Opt Ent Slide
7X06101CEA 1x Silver 4215R 8C 130W 3.2G 1x 32GB 2933 Option Option 3.5", Open bay Open 2x PCIe x8 1x 750W Titanium Opt Ent Slide
7X06A0JLEA 1x Silver 4215R 8C 130W 3.2G 1x 32GB 2933 930-8i 8x 2.5" SAS/24, Open bay Open 2x PCIe x8 1x 750W Opt Ent Slide
7X06A0JNEA 1x Silver 4215R 8C 130W 3.2G 1x 32GB 2933 930-8i 8x 3.5" SAS/8, Open bay Open 2x PCIe x8 1x 750W Opt Ent Slide
7X06A0K4EA 1x Silver 4215R 8C 130W 3.2G 1x 32GB 2933 Option Option 24x 2.5", Open bay Open 2x PCIe x8 1x 750W Opt Ent Slide
7X06A0MFEA 1x Silver 4215R 8C 130W 3.2G 1x 32GB 2933 940-8i 4GB 8x 2.5" SAS/24, Open bay Open 2x PCIe x8 1x 750W Opt Ent Slide
7X06A0NREA 1x Silver 4215R 8C 130W 3.2G 1x 32GB 2933 940-8i 4GB 8x 2.5" SAS/24, Open bay Open 2x PCIe x8 1x 750W Opt Ent Slide
7X06A0NWEA 1x Silver 4215R 8C 130W 3.2G 1x 32GB 2933 9350-8i 8x 2.5" SAS/24, Open bay Open 2x PCIe x8 1x 750W Opt Ent Slide
7X06A0P8EA 1x Silver 4215R 8C 130W 3.2G 1x 32GB 2933 940-16i 4GB 12x 3.5" SAS/12, Open bay Open 2x PCIe x8 1x 1100W Opt Ent Slide
7X06A0P9EA 1x Silver 4215R 8C 130W 3.2G 1x 32GB 2933 9350-8i 8x 3.5" SAS/8, Open bay Open 2x PCIe x8 1x 750W Opt Ent Slide
7X06A0PEEA 1x Silver 4215R 8C 130W 3.2G 1x 32GB 2933 940-8i 4GB 8x 3.5" SAS/8, Open bay Open 2x PCIe x8 1x 750W Opt Ent Slide
7X06A0PHEA 1x Silver 4215R 8C 130W 3.2G 1x 32GB 2933 9350-16i 8xSAS+ 4xAny 3.5"/12, Open bay Open 2x PCIe x8 1x 1100W Opt Ent Slide
7X06A0PWEA 1x Silver 4215R 8C 130W 3.2G 1x 32GB 2933 9350-8i 8x 2.5" SAS/24, Open bay Open 2x PCIe x8 1x 750W Titanium Opt Ent Slide
7X06A0PYEA 1x Silver 4215R 8C 130W 3.2G 1x 32GB 2933 Option Option 24x 2.5", Open bay Open 2x PCIe x8 1x 750W Titanium Opt Ent Slide
7X06A0QEEA 1x Silver 4215R 8C 130W 3.2G 1x 64GB 2933 Option Option 24x 2.5", Open bay Open 2x PCIe x8 1x 750W Titanium Opt Ent Slide
7X06A0QZEA 1x Silver 4215R 8C 130W 3.2G 1x 32GB 2933 930-8i 8x 2.5" SAS/24, Open bay Open 2x PCIe x8 1x 750W Titanium Opt Ent Slide
7X06A0AXEA 1x Silver 4216 16C 100W 2.1G 1x 16GB 2Rx8 2666 Option Option 24x 2.5", Open bay Open 2x PCIe x8 1x 750W Opt Ent Slide
7X06A0MLEA 1x Silver 4216 16C 100W 2.1G 1x 32GB 2933 940-8i 4GB 8x 2.5" SAS/24, Open bay Open 2x PCIe x8 1x 750W Opt Ent Slide
7X06A0NQEA 1x Silver 4216 16C 100W 2.1G 1x 32GB 2933 940-8i 4GB 8x 2.5" SAS/24, Open bay Open 2x PCIe x8 1x 750W Opt Ent Slide
7X06A0NXEA 1x Silver 4216 16C 100W 2.1G 1x 32GB 2933 9350-8i 8x 2.5" SAS/24, Open bay Open 2x PCIe x8 1x 750W Opt Ent Slide
7X06A0B5EA 1x Gold 5217 8C 115W 3.0G 1x 16GB 2Rx8 2666 Option Option 24x 2.5", Open bay Open 2x PCIe x8 1x 1100W Opt Ent Slide
7X06A0H6EA 1x Gold 5217 8C 115W 3.0G 1x 32GB 2933 Option Option 24x 2.5", Open bay Open 2x PCIe x8 1x 1100W Opt Ent Slide
7X06A0ASEA 1x Gold 5218 16C 125W 2.3G 1x 32GB 2666 930-8i 8x 2.5" SAS/24, Open bay Open 2x PCIe x8 1x 750W Opt Ent Slide
7X06A0BCEA 1x Gold 5218 16C 125W 2.3G 1x 16GB 2Rx8 2666 Option Option 24x 2.5", Open bay Open 2x PCIe x8 1x 1100W Opt Ent Slide
7X06A0JHEA 1x Gold 5218R 20C 125W 2.1G 1x 32GB 2933 930-8i 8x 2.5" SAS/24, Open bay Open 2x PCIe x8 1x 750W Opt Ent Slide
7X06A0K5EA 1x Gold 5218R 20C 125W 2.1G 1x 32GB 2933 Option Option 24x 2.5", Open bay Open 2x PCIe x8 1x 750W Opt Ent Slide
7X06A0LSEA 2x Gold 5218R 20C 125W 2.1G 2x 32GB 2933 930-8i 8x 2.5" SAS/24, Open bay Open 2x PCIe x8 1x 750W Opt Ent Slide
7X06A0MGEA 1x Gold 5218R 20C 125W 2.1G 1x 32GB 2933 940-8i 4GB 8x 2.5" SAS/24, Open bay Open 2x PCIe x8 1x 750W Opt Ent Slide
7X06A0NSEA 1x Gold 5218R 20C 125W 2.1G 1x 32GB 2933 940-8i 4GB 8x 2.5" SAS/24, Open bay Open 2x PCIe x8 1x 750W Opt Ent Slide
7X06A0NVEA 1x Gold 5218R 20C 125W 2.1G 1x 32GB 2933 9350-8i 8x 2.5" SAS/24, Open bay Open 2x PCIe x8 1x 750W Opt Ent Slide
7X06A0R0EA 1x Gold 5218R 20C 125W 2.1G 1x 32GB 2933 930-8i 8x 2.5" SAS/24, Open bay Open 2x PCIe x8 1x 750W Titanium Opt Ent Slide
7X06A0K6EA 1x Gold 5220R 24C 150W 2.2G 1x 32GB 2933 Option Option 24x 2.5", Open bay Open 2x PCIe x8 1x 750W Opt Ent Slide
7X06A0B8EA 1x Gold 5222 4C 105W 3.8G 1x 16GB 2Rx8 2933 Option Option 24x 2.5", Open bay Open 2x PCIe x8 1x 1100W Opt Ent Slide
7X06A0J9EA 1x Gold 6226 12C 125W 2.7G 1x 32GB 2933 Option Option 24x 2.5", Open bay Open 2x PCIe x8 1x 1100W Opt Ent Slide
7X06A0JJEA 1x Gold 6226R 16C 150W 2.9G 1x 32GB 2933 930-8i 8x 2.5" SAS/24, Open bay Open 2x PCIe x8 1x 750W Opt Ent Slide
7X06A0K7EA 1x Gold 6226R 16C 150W 2.9G 1x 32GB 2933 Option Option 24x 2.5", Open bay Open 2x PCIe x8 1x 750W Opt Ent Slide
7X06A0MHEA 1x Gold 6226R 16C 150W 2.9G 1x 32GB 2933 940-8i 4GB 8x 2.5" SAS/24, Open bay Open 2x PCIe x8 1x 750W Opt Ent Slide
7X06A0NTEA 1x Gold 6226R 16C 150W 2.9G 1x 32GB 2933 940-8i 4GB 8x 2.5" SAS/24, Open bay Open 2x PCIe x8 1x 750W Opt Ent Slide
7X06A0NUEA 1x Gold 6226R 16C 150W 2.9G 1x 32GB 2933 9350-8i 8x 2.5" SAS/24, Open bay Open 2x PCIe x8 1x 750W Opt Ent Slide
7X06A0PJEA 1x Gold 6226R 16C 150W 2.9G 1x 32GB 2933 Option Option 24x 2.5", Open bay Open 2x PCIe x8 1x 750W Opt Ent Slide
7X06A0PTEA 1x Gold 6226R 16C 150W 2.9G 1x 32GB 2933 9350-8i 8x 2.5" SAS/24, Open bay Open 2x PCIe x8 1x 750W Titanium Opt Ent Slide
7X06A0QBEA 1x Gold 6226R 16C 150W 2.9G 1x 64GB 2933 Option Option 24x 2.5", Open bay Open 2x PCIe x8 1x 750W Titanium Opt Ent Slide
7X06A0QCEA 1x Gold 6226R 16C 150W 2.9G 1x 64GB 2933 9350-8i 8x 2.5" SAS/24, Open bay Open 2x PCIe x8 1x 750W Titanium Opt Ent Slide
7X06A0QLEA 1x Gold 6226R 16C 150W 2.9G 1x 32GB 2933 Option Option 24x 2.5", Open bay Open 2x PCIe x8 1x 750W Titanium Opt Ent Slide
7X06A0R1EA 1x Gold 6226R 16C 150W 2.9G 1x 32GB 2933 930-8i 8x 2.5" SAS/24, Open bay Open 2x PCIe x8 1x 750W Titanium Opt Ent Slide
7X06101DEA 1x Gold 6230 20C 125W 2.1G 1x 32GB 2933 Option Option 24x 2.5", Open bay Open 2x PCIe x8 1x 750W Titanium Opt Ent Slide
7X06A0BAEA 1x Gold 6230 20C 125W 2.1G 1x 32GB 2933 930-8i 8x 2.5" SAS/24, Open bay Open 2x PCIe x8 1x 750W Opt Ent Slide
7X06A0BBEA 1x Gold 6230 20C 125W 2.1G 1x 16GB 2Rx8 2933 Option Option 24x 2.5", Open bay Open 2x PCIe x8 1x 1100W Opt Ent Slide
7X06A0JKEA 1x Gold 6230R 26C 150W 2.1G 1x 32GB 2933 930-8i 8x 2.5" SAS/24, Open bay Open 2x PCIe x8 1x 750W Opt Ent Slide
7X06A0K2EA 1x Gold 6230R 26C 150W 2.1G 1x 32GB 2933 Option Option 24x 2.5", Open bay Open 2x PCIe x8 1x 750W Opt Ent Slide
7X06A0JCEA 1x Gold 6234 8C 130W 3.3G 1x 32GB 2933 Option Option 24x 2.5", Open bay Open 2x PCIe x8 1x 1100W Opt Ent Slide
7X06A0JUEA 1x Gold 6238R 28C 165W 2.2G 1x 32GB 2933 Option Option 24x 2.5", Open bay Open 2x PCIe x8 1x 750W Opt Ent Slide
7X06A0AQEA 1x Gold 6240 18C 150W 2.6G 1x 16GB 2Rx8 2933 Option Option 24x 2.5", Open bay Open 2x PCIe x8 1x 1100W Opt Ent Slide
7X06A0JMEA 1x Gold 6240R 24C 165W 2.4G 1x 32GB 2933 Option Option 24x 2.5", Open bay Open 2x PCIe x8 1x 750W Opt Ent Slide
7X06A0B1EA 1x Gold 6242 16C 150W 2.8G 1x 16GB 2Rx8 2933 Option Option 24x 2.5", Open bay Open 2x PCIe x8 1x 1100W Opt Ent Slide
7X06A0JQEA 1x Gold 6242R 20C 205W 3.1G 1x 32GB 2933 Option Option 24x 2.5", Open bay Open 2x PCIe x8 1x 1100W Opt Ent Slide
7X06A0B6EA 1x Gold 6244 8C 150W 3.6G 1x 16GB 2Rx8 2933 Option Option 24x 2.5", Open bay Open 2x PCIe x8 1x 1100W Opt Ent Slide
7X06A0J7EA 1x Gold 6246 12C 165W 3.3G 1x 32GB 2933 Option Option 24x 2.5", Open bay Open 2x PCIe x8 1x 1100W Opt Ent Slide
7X06A0JTEA 1x Gold 6246R 16C 205W 3.4G 1x 32GB 2933 Option Option 24x 2.5", Open bay Open 2x PCIe x8 1x 1100W Opt Ent Slide
7X06A0AUEA 1x Gold 6248 20C 150W 2.5G 1x 16GB 2Rx8 2933 Option Option 24x 2.5", Open bay Open 2x PCIe x8 1x 1100W Opt Ent Slide
7X06A0GUEA 2x Gold 6248 20C 150W 2.5G 12x 32GB 2933 Option Option 24x 2.5", Open bay, 2x 128GB M.2 4x10Gb RJ45 5x PCIe x8, 2x PCIe x16
4x T4 GPU
2x 1600W Opt Ent Slide
7X06A0GVEA 2x Gold 6248 20C 150W 2.5G 12x 32GB 2933 Option Option 24x 2.5", Open bay, 2x 128GB M.2 4x10Gb RJ45 3x PCIe x8, 3x PCIe x16
2x M10 GPU
2x 1600W Opt Ent Slide
7X06A0GWEA 2x Gold 6248 20C 150W 2.5G 12x 32GB 2933 Option Option 24x 2.5", Open bay, 2x 128GB M.2 4x10Gb RJ45 5x PCIe x8, 2x PCIe x16
4x T4 GPU
2x 1600W Opt Ent Slide
7X06A0GYEA 2x Gold 6248 20C 150W 2.5G 12x 32GB 2933 Option Option 24x 2.5", Open bay, 2x 128GB M.2 4x10Gb RJ45 3x PCIe x8, 3x PCIe x16
2x M10 GPU
2x 1600W Opt Ent Slide
7X06A0HWEA 2x Gold 6248 20C 150W 2.5G 12x 32GB 2933 Option Option 24x 2.5", Open bay, 2x 128GB M.2 4x10Gb RJ45 5x PCIe x8, 2x PCIe x16
4x T4 GPU
2x 1600W Opt Ent Slide
7X06A0HXEA 2x Gold 6248 20C 150W 2.5G 12x 32GB 2933 Option Option 24x 2.5", Open bay, 2x 128GB M.2 4x10Gb RJ45 3x PCIe x8, 3x PCIe x16
2x M10 GPU
2x 1600W Opt Ent Slide
7X06A0HYEA 2x Gold 6248 20C 150W 2.5G 12x 32GB 2933 Option Option 24x 2.5", Open bay, 2x 128GB M.2 4x10Gb RJ45 5x PCIe x8, 2x PCIe x16
4x T4 GPU
2x 1600W Opt Ent Slide
7X06A0J0EA 2x Gold 6248 20C 150W 2.5G 12x 32GB 2933 Option Option 24x 2.5", Open bay, 2x 128GB M.2 4x10Gb RJ45 5x PCIe x8, 2x PCIe x16
4x T4 GPU
2x 1600W Opt Adv Slide
7X06A0J5EA 2x Gold 6248 20C 150W 2.5G 12x 32GB 2933 Option Option 24x 2.5", Open bay, 1x 128GB M.2 4x10Gb RJ45 3x PCIe x8, 3x PCIe x16
2x M10 GPU
2x 1600W Opt Ent Slide
7X06A0J6EA 2x Gold 6248 20C 150W 2.5G 12x 32GB 2933 Option Option 24x 2.5", Open bay, 1x 128GB M.2 4x10Gb RJ45 3x PCIe x8, 3x PCIe x16
2x M10 GPU
2x 1600W Opt Ent Slide
7X06A0JBEA 2x Gold 6248 20C 150W 2.5G 12x 32GB 2933 Option Option 24x 2.5", Open bay, 1x 128GB M.2 4x10Gb RJ45 5x PCIe x8, 2x PCIe x16
4x T4 GPU
2x 1600W Opt Ent Slide
7X06A0JEEA 2x Gold 6248 20C 150W 2.5G 12x 32GB 2933 Option Option 24x 2.5", Open bay, 1x 128GB M.2 4x10Gb RJ45 5x PCIe x8, 2x PCIe x16
4x T4 GPU
2x 1600W Opt Ent Slide
7X06A0JVEA 1x Gold 6248R 24C 205W 3.0G 1x 32GB 2933 Option Option 24x 2.5", Open bay Open 2x PCIe x8 1x 1100W Opt Ent Slide
7X06A0JWEA 1x Gold 6250 8C 185W 3.9G 1x 32GB 2933 Option Option 24x 2.5", Open bay Open 2x PCIe x8 1x 1100W Opt Ent Slide
7X06A0AYEA 1x Gold 6254 18C 200W 3.1G 1x 32GB 2933 Option Option 24x 2.5", Open bay Open 2x PCIe x8 1x 1100W Opt Ent Slide
7X06A0K0EA 1x Gold 6256 12C 205W 3.6G 1x 32GB 2933 Option Option 24x 2.5", Open bay Open 2x PCIe x8 1x 1100W Opt Ent Slide
7X06A0K3EA 1x Gold 6258R 28C 205W 2.7G 1x 32GB 2933 Option Option 24x 2.5", Open bay Open 2x PCIe x8 1x 1100W Opt Ent Slide

† Processor description: Processor model, number of cores, thermal design power (TDP), core frequency

Models for Hong Kong, Taiwan, Korea (HTK)

Table 8. Models for Hong Kong, Taiwan, Korea (HTK)
Model Intel Xeon Scalable processor† Memory RAID Drive bays and drives LOM Slots Power
supply
Front
VGA
XCC Rail
kit
Standard models with a 3-year warranty (machine type 7X06)
7X06A0NKCN 2x Silver 4214 12C 85W 2.2G 6x 32GB 2933 930-16i 8GB 12x 3.5" SAS/12, 2x 3.2TB PM1645a, 2x 128GB M.2 4x1Gb 2x PCIe x8, 2x PCIe x16 2x 750W Opt Ent Slide
7X06100YCN 2x Gold 5217 8C 115W 3.0G 4x 16GB 2Rx8 2933 930-8i 8x 3.5" SAS/8, 2x 4TB SATA HDD+ 2x 480GB S4510 4x1Gb 2x PCIe x8 2x 750W Opt Std Slide
7X06100ZCN 2x Gold 5217 8C 115W 3.0G 4x 16GB 2Rx8 2933 930-8i 8x 3.5" SAS/8, 2x 4TB SATA HDD+ 2x 480GB S4510 4x1Gb 3x PCIe x8, 3x PCIe x16 2x 750W Opt Std Slide
7X061010CN 2x Gold 5217 8C 115W 3.0G 2x 16GB 2Rx8 2933 930-8i 8x 3.5" SAS/8, 2x 4TB SATA HDD+ 2x 480GB S4510 4x1Gb 3x PCIe x8, 3x PCIe x16 2x 750W Opt Std Slide
7X06100XCN 1x Gold 5218 16C 125W 2.3G 4x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS/24, 4x 1.2TB 10K+ 2x 480GB S4510 4x1Gb 2x PCIe x8 2x 750W Opt Std Slide
TopSeller models with a 3-year warranty (machine type 7X06)
7X06A0BSCN 1x Bronze 3204 6C 85W 1.9G 1x 16GB 2Rx8 2933 930-8i 8x 3.5" SAS/8, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0D3CN 1x Bronze 3204 6C 85W 1.9G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS/24, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0CDCN 1x Silver 4208 8C 85W 2.1G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS/24, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0CECN 1x Silver 4208 8C 85W 2.1G 1x 16GB 2Rx8 2933 930-8i 8x 3.5" SAS/8, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0CTCN 1x Silver 4210 10C 85W 2.2G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS/24, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0DCCN 1x Silver 4210 10C 85W 2.2G 1x 16GB 2Rx8 2933 930-8i 8x 3.5" SAS/8, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0LDCN 1x Silver 4210R 10C 100W 2.4G 1x 16GB 2Rx8 2933 Option Option 3.5", Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0LFCN 1x Silver 4210R 10C 100W 2.4G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS/24, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0LKCN 1x Silver 4210R 10C 100W 2.4G 1x 16GB 2Rx8 2933 Option Option 24x 2.5", Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0BRCN 1x Silver 4214 12C 85W 2.2G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS/24, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0D5CN 1x Silver 4214 12C 85W 2.2G 1x 16GB 2Rx8 2933 930-8i 8x 3.5" SAS/8, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0L5CN 1x Silver 4214R 12C 100W 2.4G 1x 16GB 2Rx8 2933 Option Option 24x 2.5", Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0LLCN 1x Silver 4214R 12C 100W 2.4G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS/24, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0LPCN 1x Silver 4214R 12C 100W 2.4G 1x 16GB 2Rx8 2933 930-8i 8x 3.5" SAS/8, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0BVCN 1x Silver 4215 8C 85W 2.5G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS/24, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0DJCN 1x Silver 4215 8C 85W 2.5G 1x 16GB 2Rx8 2933 930-8i 8x 3.5" SAS/8, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0LACN 1x Silver 4215R 8C 130W 3.2G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS/24, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0LJCN 1x Silver 4215R 8C 130W 3.2G 1x 16GB 2Rx8 2933 Option Option 24x 2.5", Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0LNCN 1x Silver 4215R 8C 130W 3.2G 1x 16GB 2Rx8 2933 Option Option 3.5", Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0BNCN 1x Silver 4216 16C 100W 2.1G 1x 16GB 2Rx8 2933 930-8i 8x 3.5" SAS/8, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0CRCN 1x Silver 4216 16C 100W 2.1G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS/24, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0C7CN 1x Gold 5215 10C 85W 2.5G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS/24, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0D7CN 1x Gold 5215 10C 85W 2.5G 1x 16GB 2Rx8 2933 930-8i 8x 3.5" SAS/8, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0CUCN 1x Gold 5217 8C 115W 3.0G 1x 16GB 2Rx8 2933 930-8i 8x 3.5" SAS/8, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0D6CN 1x Gold 5217 8C 115W 3.0G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS/24, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0C8CN 1x Gold 5218 16C 125W 2.3G 1x 16GB 2Rx8 2933 930-8i 8x 3.5" SAS/8, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0DFCN 1x Gold 5218 16C 125W 2.3G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS/24, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0L4CN 1x Gold 5218R 20C 125W 2.1G 1x 16GB 2Rx8 2933 930-8i 8x 3.5" SAS/8, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0L7CN 1x Gold 5218R 20C 125W 2.1G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS/24, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0BYCN 1x Gold 5220 18C 125W 2.2G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS/24, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0C0CN 1x Gold 5220 18C 125W 2.2G 1x 16GB 2Rx8 2933 930-8i 8x 3.5" SAS/8, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0LECN 1x Gold 5220R 24C 150W 2.2G 1x 16GB 2Rx8 2933 930-8i 8x 3.5" SAS/8, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0LQCN 1x Gold 5220R 24C 150W 2.2G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS/24, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0LGCN 1x Gold 6226R 16C 150W 2.9G 1x 16GB 2Rx8 2933 930-8i 8x 3.5" SAS/8, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0LHCN 1x Gold 6226R 16C 150W 2.9G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS/24, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0DACN 1x Gold 6230 20C 125W 2.1G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS/24, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0DECN 1x Gold 6230 20C 125W 2.1G 1x 16GB 2Rx8 2933 930-8i 8x 3.5" SAS/8, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0LMCN 1x Gold 6230R 26C 150W 2.1G 1x 16GB 2Rx8 2933 930-8i 8x 3.5" SAS/8, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0LRCN 1x Gold 6230R 26C 150W 2.1G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS/24, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0LBCN 1x Gold 6238R 28C 165W 2.2G 1x 16GB 2Rx8 2933 930-8i 8x 3.5" SAS/8, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0BXCN 1x Gold 6240 18C 150W 2.6G 1x 16GB 2Rx8 2933 930-8i 8x 3.5" SAS/8, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0DNCN 1x Gold 6240 18C 150W 2.6G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS/24, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0L9CN 1x Gold 6240R 24C 165W 2.4G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS/24, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0BHCN 1x Gold 6242 16C 150W 2.8G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS/24, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0D9CN 1x Gold 6242 16C 150W 2.8G 1x 16GB 2Rx8 2933 930-8i 8x 3.5" SAS/8, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0L6CN 1x Gold 6242R 20C 205W 3.1G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS/24, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0C4CN 1x Gold 6244 8C 150W 3.6G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS/24, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0L8CN 1x Gold 6246R 16C 205W 3.4G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS/24, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0BDCN 1x Gold 6248 20C 150W 2.5G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS/24, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0CMCN 1x Gold 6248 20C 150W 2.5G 1x 16GB 2Rx8 2933 930-8i 8x 3.5" SAS/8, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0LCCN 1x Gold 6248R 24C 205W 3.0G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS/24, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0BTCN 1x Gold 6252 24C 150W 2.1G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS/24, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0DMCN 1x Gold 6252 24C 150W 2.1G 1x 16GB 2Rx8 2933 930-8i 8x 3.5" SAS/8, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0BMCN 1x Gold 6254 18C 200W 3.1G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS/24, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt

† Processor description: Processor model, number of cores, thermal design power (TDP), core frequency

Models for India

Table 9. Models for India
Model Intel Xeon Scalable processor† Memory RAID Drive bays and drives LOM Slots Power
supply
Front
VGA
XCC Rail
kit
Standard models with a 3-year warranty (machine type 7X06)
7X06A0MYSG 2x Silver 4214 12C 85W 2.2G 6x 32GB 2933 930-16i 8GB 12x 3.5" SAS/12, 2x 3.2TB PM1645a, 2x 128GB M.2 4x1Gb 2x PCIe x8, 2x PCIe x16 2x 750W Opt Ent Slide
7X06A0LYSG 1x Gold 5218 16C 125W 2.3G 1x 32GB 2933 930-8i 8x 2.5" SAS/24, Open bay 2x10Gb RJ45 2x PCIe x8 2x 750W Opt Ent Slide
7X06A0LZSG 1x Gold 5220 18C 125W 2.2G 1x 32GB 2933 930-8i 8x 2.5" SAS/24, Open bay 2x10Gb RJ45 2x PCIe x8 2x 750W Opt Ent Opt
7X06A0MTSG 1x Gold 5220 18C 125W 2.2G 1x 32GB 2933 930-8i 8x 2.5" SAS/24, Open bay 2x10Gb RJ45 2x PCIe x8 2x 750W Opt Ent Slide
TopSeller models with a 3-year warranty (machine type 7X06)
7X06A0CXSG 1x Bronze 3204 6C 85W 1.9G 1x 16GB 2Rx8 2933 930-8i 8x 3.5" SAS/8, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0D4SG 1x Bronze 3204 6C 85W 1.9G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS/24, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0BWSG 1x Silver 4208 8C 85W 2.1G 1x 16GB 2Rx8 2933 930-8i 8x 3.5" SAS/8, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0CYSG 1x Silver 4208 8C 85W 2.1G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS/24, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0BLSG 1x Silver 4210 10C 85W 2.2G 1x 16GB 2Rx8 2933 930-8i 8x 3.5" SAS/8, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0C6SG 1x Silver 4210 10C 85W 2.2G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS/24, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0C5SG 1x Silver 4214 12C 85W 2.2G 1x 16GB 2Rx8 2933 930-8i 8x 3.5" SAS/8, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0C9SG 1x Silver 4214 12C 85W 2.2G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS/24, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0BESG 1x Silver 4215 8C 85W 2.5G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS/24, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0CCSG 1x Silver 4215 8C 85W 2.5G 1x 16GB 2Rx8 2933 930-8i 8x 3.5" SAS/8, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0CJSG 1x Silver 4216 16C 100W 2.1G 1x 16GB 2Rx8 2933 930-8i 8x 3.5" SAS/8, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0D8SG 1x Silver 4216 16C 100W 2.1G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS/24, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0DHSG 1x Gold 5215 10C 85W 2.5G 1x 16GB 2Rx8 2933 930-8i 8x 3.5" SAS/8, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0DKSG 1x Gold 5215 10C 85W 2.5G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS/24, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0BUSG 1x Gold 5217 8C 115W 3.0G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS/24, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0CQSG 1x Gold 5217 8C 115W 3.0G 1x 16GB 2Rx8 2933 930-8i 8x 3.5" SAS/8, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0CZSG 1x Gold 5218 16C 125W 2.3G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS/24, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0DGSG 1x Gold 5218 16C 125W 2.3G 1x 16GB 2Rx8 2933 930-8i 8x 3.5" SAS/8, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0DBSG 1x Gold 5220 18C 125W 2.2G 1x 16GB 2Rx8 2933 930-8i 8x 3.5" SAS/8, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0DLSG 1x Gold 5220 18C 125W 2.2G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS/24, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0C3SG 1x Gold 6230 20C 125W 2.1G 1x 16GB 2Rx8 2933 930-8i 8x 3.5" SAS/8, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0DDSG 1x Gold 6230 20C 125W 2.1G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS/24, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0CPSG 1x Gold 6240 18C 150W 2.6G 1x 16GB 2Rx8 2933 930-8i 8x 3.5" SAS/8, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0D1SG 1x Gold 6240 18C 150W 2.6G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS/24, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0CHSG 1x Gold 6242 16C 150W 2.8G 1x 16GB 2Rx8 2933 930-8i 8x 3.5" SAS/8, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0DQSG 1x Gold 6242 16C 150W 2.8G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS/24, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0D2SG 1x Gold 6244 8C 150W 3.6G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS/24, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0CNSG 1x Gold 6248 20C 150W 2.5G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS/24, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0D0SG 1x Gold 6248 20C 150W 2.5G 1x 16GB 2Rx8 2933 930-8i 8x 3.5" SAS/8, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0CBSG 1x Gold 6252 24C 150W 2.1G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS/24, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0CKSG 1x Gold 6252 24C 150W 2.1G 1x 16GB 2Rx8 2933 930-8i 8x 3.5" SAS/8, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt
7X06A0CLSG 1x Gold 6254 18C 200W 3.1G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS/24, Open bay Open 3x PCIe x8, 1x PCIe x16 1x 750W Opt Std Opt

† Processor description: Processor model, number of cores, thermal design power (TDP), core frequency

Models for Japan

Table 10. Models for Japan
Model Intel Xeon Scalable processor† Memory RAID Drive bays and drives LOM Slots Power
supply
Front
VGA
XCC Rail
kit
Standard models with a 3-year warranty (machine type 7X06)
7X061016JP 1x Bronze 3204 6C 85W 1.9G 1x 16GB 1Rx4 2933 9350-8i 8x 2.5" Any/24, 4x 2TB HDD 4x1Gb 3x PCIe x8, 1x PCIe x16 1x 750W Opt Adv Slide
7X06A0QTJP 1x Bronze 3204 6C 85W 1.9G 1x 16GB 2Rx8 2933 9350-8i 8x 2.5" SAS/24, Open bay 4x1Gb 5x PCIe x8 1x 750W Opt Adv Slide
7X06A0QRJP 1x Silver 4208 8C 85W 2.1G 1x 16GB 2Rx8 2933 9350-8i 8x 2.5" SAS/24, Open bay 4x1Gb 5x PCIe x8 1x 750W Opt Adv Slide
7X061017JP 1x Silver 4209T 8C 70W 2.2G 1x 16GB 1Rx4 2933 9350-8i 8x 2.5" Any/24, 4x 2TB HDD 4x1Gb 3x PCIe x8, 1x PCIe x16 1x 750W Opt Adv Slide
7X06A0QSJP 1x Silver 4209T 8C 70W 2.2G 1x 16GB 2Rx8 2933 9350-8i 8x 2.5" SAS/24, Open bay 4x1Gb 5x PCIe x8 1x 750W Opt Adv Slide
7X061018JP 1x Silver 4210 10C 85W 2.2G 1x 16GB 1Rx4 2933 9350-8i 8x 2.5" Any/24, 4x 2TB HDD 4x1Gb 3x PCIe x8, 1x PCIe x16 1x 750W Opt Adv Slide
7X06A0QMJP 1x Silver 4210 10C 85W 2.2G 1x 16GB 2Rx8 2933 9350-8i 8x 2.5" SAS/24, Open bay 4x1Gb 5x PCIe x8 1x 750W Opt Adv Slide
7X06A0KSJP 1x Silver 4214R 12C 100W 2.4G 1x 16GB 1Rx4 2666 Option Option 16x 2.5", Open bay 4x1Gb 2x PCIe x8 1x 750W Opt Adv Slide
7X06A0QPJP 1x Silver 4214R 12C 100W 2.4G 1x 16GB 2Rx8 2933 9350-8i 8x 2.5" SAS/24, Open bay 4x1Gb 5x PCIe x8 1x 750W Opt Adv Slide
7X06A0KNJP 1x Silver 4215R 8C 130W 3.2G 1x 16GB 1Rx4 2666 Option Option 16x 2.5", Open bay 4x1Gb 2x PCIe x8 1x 750W Opt Adv Slide
7X06A0QKJP 1x Silver 4215R 8C 130W 3.2G 1x 16GB 2Rx8 2933 9350-8i 8x 2.5" SAS/24, Open bay 4x1Gb 5x PCIe x8 1x 750W Opt Adv Slide
7X061019JP 1x Gold 5218 16C 125W 2.3G 1x 16GB 1Rx4 2933 9350-8i 8x 2.5" Any/24, 4x 2TB HDD 4x1Gb 3x PCIe x8, 1x PCIe x16 1x 750W Opt Adv Slide
7X06A0QQJP 1x Gold 5218 16C 125W 2.3G 1x 16GB 2Rx8 2933 9350-8i 8x 2.5" SAS/24, Open bay 4x1Gb 5x PCIe x8 1x 750W Opt Adv Slide
7X06A0KPJP 1x Gold 5218R 20C 125W 2.1G 1x 16GB 1Rx4 2666 Option Option 16x 2.5", Open bay 4x1Gb 2x PCIe x8 1x 750W Opt Adv Slide
7X06A0KVJP 1x Gold 5220R 24C 150W 2.2G 1x 16GB 1Rx4 2666 Option Option 24x 2.5", Open bay 4x1Gb 2x PCIe x8 1x 1100W Opt Adv Slide
7X06101AJP 1x Gold 5222 4C 105W 3.8G 1x 16GB 1Rx4 2933 9350-8i 8x 2.5" Any/24, 4x 2TB HDD 4x1Gb 3x PCIe x8, 1x PCIe x16 1x 750W Opt Adv Slide
7X06A0QNJP 1x Gold 5222 4C 105W 3.8G 1x 16GB 2Rx8 2933 9350-8i 8x 2.5" SAS/24, Open bay 4x1Gb 5x PCIe x8 1x 750W Opt Adv Slide
7X06A0KUJP 1x Gold 6226R 16C 150W 2.9G 1x 16GB 1Rx4 2933 Option Option 24x 2.5", Open bay 4x1Gb 2x PCIe x8 1x 1100W Opt Adv Slide
7X06A0CGJP 1x Gold 6230 20C 125W 2.1G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS/24, Open bay 4x1Gb 5x PCIe x8 1x 750W Opt Adv Slide
7X06A0KTJP 1x Gold 6230R 26C 150W 2.1G 1x 16GB 1Rx4 2933 Option Option 16x 2.5", Open bay 4x1Gb 2x PCIe x8 1x 1100W Opt Adv Slide
7X06A0KRJP 1x Gold 6238R 28C 165W 2.2G 1x 16GB 1Rx4 2933 Option Option 16x 2.5", Open bay 4x1Gb 2x PCIe x8 1x 1100W Opt Adv Slide
7X06A0DVJP 1x Gold 6240 18C 150W 2.6G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS/24, Open bay 4x1Gb 5x PCIe x8 1x 1100W Opt Adv Slide
7X06A0KMJP 1x Gold 6240R 24C 165W 2.4G 1x 16GB 1Rx4 2933 Option Option 24x 2.5", Open bay 4x1Gb 2x PCIe x8 1x 1100W Opt Adv Slide
7X06A0DRJP 1x Gold 6242 16C 150W 2.8G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS/24, Open bay 4x1Gb 5x PCIe x8 1x 1100W Opt Adv Slide
7X06A0KXJP 1x Gold 6242R 20C 205W 3.1G 1x 16GB 1Rx4 2933 Option Option 24x 2.5", Open bay 4x1Gb 2x PCIe x8 1x 1100W Opt Adv Slide
7X06A0DPJP 1x Gold 6244 8C 150W 3.6G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS/24, Open bay 4x1Gb 5x PCIe x8 1x 1600W Opt Adv Slide
7X06A0DWJP 1x Gold 6244 8C 150W 3.6G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS/24, Open bay 4x1Gb 5x PCIe x8 1x 1100W Opt Adv Slide
7X06A0KQJP 1x Gold 6246R 16C 205W 3.4G 1x 16GB 1Rx4 2933 Option Option 24x 2.5", Open bay 4x1Gb 2x PCIe x8 1x 1100W Opt Adv Slide
7X06A0DTJP 1x Gold 6248 20C 150W 2.5G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS/24, Open bay 4x1Gb 5x PCIe x8 1x 1100W Opt Adv Slide
7X06A0KWJP 1x Gold 6248R 24C 205W 3.0G 1x 16GB 1Rx4 2933 Option Option 24x 2.5", Open bay 4x1Gb 2x PCIe x8 1x 1100W Opt Adv Slide
7X06A0DUJP 1x Gold 6252 24C 150W 2.1G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS/24, Open bay 4x1Gb 5x PCIe x8 1x 1100W Opt Adv Slide
7X06A0DSJP 1x Gold 6254 18C 200W 3.1G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS/24, Open bay 4x1Gb 5x PCIe x8 1x 1100W Opt Adv Slide
7X06A0L0JP 1x Gold 6258R 28C 205W 2.7G 1x 16GB 1Rx4 2933 Option Option 24x 2.5", Open bay 4x1Gb 2x PCIe x8 1x 1100W Opt Adv Slide
7X06A0DXJP 1x Platinum 8280M 28C 205W 2.7G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS/24, Open bay 4x1Gb 5x PCIe x8 1x 1100W Opt Adv Slide
TopSeller models with a 3-year warranty (machine type 7X06)
7X06A0BKJP 1x Bronze 3204 6C 85W 1.9G 1x 16GB 1Rx4 2666 730-8i 2GB 8x 3.5" SAS/8, Open bay 4x1Gb 5x PCIe x8 1x 550W Opt Adv Slide
7X06A0BQJP 1x Bronze 3204 6C 85W 1.9G 1x 16GB 1Rx4 2666 730-8i 2GB 8x 2.5" SAS/24, Open bay 4x1Gb 5x PCIe x8 1x 750W Opt Adv Slide
7X06A0KZJP 1x Bronze 3206R 8C 85W 1.9G 1x 16GB 1Rx4 2666 Option Option 16x 2.5", Open bay 4x1Gb 2x PCIe x8 1x 750W Opt Adv Slide
7X06A0BPJP 1x Silver 4208 8C 85W 2.1G 1x 16GB 1Rx4 2666 730-8i 2GB 8x 2.5" SAS/24, Open bay 4x1Gb 5x PCIe x8 1x 750W Opt Adv Slide
7X06A0BGJP 1x Silver 4210 10C 85W 2.2G 1x 16GB 1Rx4 2666 730-8i 2GB 8x 2.5" SAS/24, Open bay 4x1Gb 5x PCIe x8 1x 750W Opt Adv Slide
7X06A0CAJP 1x Silver 4210 10C 85W 2.2G 1x 16GB 1Rx4 2666 930-16i 4GB 12x 3.5" SAS/12, Open bay 4x1Gb 5x PCIe x8 1x 750W Opt Adv Slide
7X06A0KYJP 1x Silver 4210R 10C 100W 2.4G 1x 16GB 1Rx4 2666 Option Option 16x 2.5", Open bay 4x1Gb 2x PCIe x8 1x 750W Opt Adv Slide
7X06A0BFJP 1x Silver 4214 12C 85W 2.2G 1x 16GB 1Rx4 2666 730-8i 2GB 8x 2.5" SAS/24, Open bay 4x1Gb 5x PCIe x8 1x 750W Opt Adv Slide
7X06A0BJJP 1x Silver 4215 8C 85W 2.5G 1x 16GB 1Rx4 2666 730-8i 2GB 8x 2.5" SAS/24, Open bay 4x1Gb 5x PCIe x8 1x 750W Opt Adv Slide
7X06A0BZJP 1x Silver 4216 16C 100W 2.1G 1x 16GB 1Rx4 2666 730-8i 2GB 8x 2.5" SAS/24, Open bay 4x1Gb 5x PCIe x8 1x 750W Opt Adv Slide
7X06A0C2JP 1x Silver 4216 16C 100W 2.1G 1x 16GB 1Rx4 2666 930-16i 4GB 12x 3.5" SAS/12, Open bay 4x1Gb 5x PCIe x8 1x 750W Opt Adv Slide
7X06A0C1JP 1x Gold 5215 10C 85W 2.5G 1x 16GB 1Rx4 2666 730-8i 2GB 8x 2.5" SAS/24, Open bay 4x1Gb 5x PCIe x8 1x 750W Opt Adv Slide
7X06A0CVJP 1x Gold 5217 8C 115W 3.0G 1x 16GB 1Rx4 2666 730-8i 2GB 8x 2.5" SAS/24, Open bay 4x1Gb 5x PCIe x8 1x 750W Opt Adv Slide
7X06A0CWJP 1x Gold 5218 16C 125W 2.3G 1x 16GB 1Rx4 2666 730-8i 2GB 8x 2.5" SAS/24, Open bay 4x1Gb 5x PCIe x8 1x 750W Opt Adv Slide
7X06A0CSJP 1x Gold 5220 18C 125W 2.2G 1x 16GB 1Rx4 2666 730-8i 2GB 8x 2.5" SAS/24, Open bay 4x1Gb 5x PCIe x8 1x 750W Opt Adv Slide
7X06A0CFJP 1x Gold 5222 4C 105W 3.8G 1x 16GB 1Rx4 2666 730-8i 2GB 8x 2.5" SAS/24, Open bay 4x1Gb 5x PCIe x8 1x 750W Opt Adv Slide

† Processor description: Processor model, number of cores, thermal design power (TDP), core frequency

Models for Latin American countries (except Brazil)

Table 11. Models with a 3-year warranty for Latin American countries (except Brazil)
Model Intel Xeon Scalable processor† Memory RAID Drive bays and drives LOM Slots Power
supply
Front
VGA
XCC Rail
kit
Standard models with a 3-year warranty (machine type 7X06)
7X06A0H8LA 1x Silver 4210 10C 85W 2.2G 1x 32GB 2933 730-8i 2GB 8x 2.5" SAS/24, Open bay 4x1Gb 5x PCIe x8 1x 750W Yes Std Slide
7X06A0M6LA 1x Silver 4210R 10C 100W 2.4G 1x 16GB 2Rx8 2933 730-8i 1GB 8x 2.5" SAS/16, Open bay 4x1Gb 5x PCIe x8 1x 750W Yes Std Slide
7X06A0M4LA 1x Silver 4214R 12C 100W 2.4G 1x 32GB 2933 730-8i 1GB 8x 2.5" SAS/16, Open bay 4x1Gb 5x PCIe x8 1x 750W Yes Std Slide
7X06A0MBLA 1x Gold 5218R 20C 125W 2.1G 1x 32GB 2933 930-16i 4GB 8x 2.5" SAS/16, Open bay 2x10Gb RJ45 5x PCIe x8 2x 750W Yes Ent Slide
7X06A0HBLA 1x Gold 5220 18C 125W 2.2G 1x 32GB 2933 730-8i 2GB 8x 2.5" SAS/24, Open bay 4x1Gb 5x PCIe x8 1x 1100W Yes Std Slide
7X06A0MCLA 1x Gold 6230R 26C 150W 2.1G 2x 32GB 2933 930-16i 4GB 16x 2.5" SAS/16, Open bay 4x10Gb RJ45 5x PCIe x8 2x 1100W Yes Ent Slide
7X06A0M9LA 1x Gold 6240R 24C 165W 2.4G 2x 32GB 2933 930-16i 4GB 16x 2.5" SAS/16, Open bay 4x10Gb RJ45 5x PCIe x8 2x 1100W Yes Ent Slide
7X06A0J3LA 2x Platinum 8276M 28C 165W 2.2G 24x 128GB 2933 930-24i 8xAny+ 16xSAS 2.5"/24, 16x 960GB S4610 4x1Gb 2x PCIe x8, 2x PCIe x16 2x 1100W Opt Ent Slide CMA
TopSeller models with a 3-year warranty (machine type 7X06)
7X06A0H9LA 1x Silver 4214 12C 85W 2.2G 1x 32GB 2933 730-8i 2GB 8x 2.5" SAS/24, Open bay 4x1Gb 5x PCIe x8 1x 750W Yes Std Slide
7X06A0HALA 1x Silver 4216 16C 100W 2.1G 1x 32GB 2933 730-8i 2GB 8x 2.5" SAS/24, Open bay 4x1Gb 5x PCIe x8 1x 750W Yes Std Slide

† Processor description: Processor model, number of cores, thermal design power (TDP), core frequency

Models for USA and Canada

Table 12. Models for USA and Canada
Model Intel Xeon Scalable processor† Memory RAID Drive bays and drives LOM Slots Power
supply
Front
VGA
XCC Rail
kit
Standard models with a 3-year warranty (machine type 7X06)
7X06A0FHNA 1x Silver 4208 8C 85W 2.1G 1x 16GB 2Rx8 2933 Option Option 24x 2.5", Open bay Open 2x PCIe x8 1x 750W Yes Ent Slide
7X06A0KLNA 1x Silver 4208 8C 85W 2.1G 1x 16GB 2Rx8 2933 530-8i 8x 3.5" SAS/8, Open bay Open 2x PCIe x8 1x 750W Yes Ent Slide
7X06A0NDNA 1x Silver 4208 8C 85W 2.1G 1x 32GB 2933 Option Option 3.5", Open bay Open 2x PCIe x8 1x 750W Yes Ent Slide
7X06A0NFNA 1x Silver 4208 8C 85W 2.1G 1x 32GB 2933 Option Option 24x 2.5", Open bay Open 2x PCIe x8 1x 750W Yes Ent Slide
7X06A0QHNA 1x Silver 4208 8C 85W 2.1G 4x 16GB 2Rx8 2933 430-8i HBA 8x 2.5" SAS/24, 2x 240GB 5400 PRO+ 4x 1.92TB 5400 MAX Open 2x PCIe x8 1x 750W Yes Ent Slide
7X06A0M1NA 1x Silver 4210 10C 85W 2.2G 2x 64GB 2933 530-16i 8x 2.5" Any/24, 2x 240GB PM883+ 3x 3.84TB PM983 4x10Gb SFP+ 3x PCIe x8, 1x PCIe x16 2x 750W Opt Ent Slide
7X06A0FENA 1x Silver 4214 12C 85W 2.2G 1x 16GB 2Rx8 2933 Option Option 24x 2.5", Open bay Open 2x PCIe x8 1x 750W Yes Ent Slide
7X06A0N9NA 2x Silver 4214 12C 85W 2.2G 6x 32GB 2933 930-16i 8GB 12x 3.5" SAS/12, 2x 3.2TB PM1645a, 2x 128GB M.2 4x1Gb 3x PCIe x8, 2x PCIe x16 2x 750W Opt Ent Slide
7X06A0NGNA 1x Silver 4214 12C 85W 2.2G 1x 32GB 2933 Option Option 24x 2.5", Open bay Open 2x PCIe x8 1x 750W Yes Ent Slide
7X06A0NHNA 2x Silver 4214 12C 85W 2.2G 6x 32GB 2933 930-16i 8GB 12x 3.5" SAS/12, 2x 3.2TB PM1645a, 2x 128GB M.2 4x1Gb 3x PCIe x8, 2x PCIe x16 2x 750W Opt Ent Slide
7X06A0PNNA 2x Silver 4214 12C 85W 2.2G 6x 32GB 2933 930-16i 8GB 12x 3.5" SAS/12, 2x 3.2TB PM1645a, 2x 128GB M.2 4x1Gb 3x PCIe x8, 2x PCIe x16 2x 750W Opt Ent Slide
7X06A0QJNA 1x Silver 4214 12C 85W 2.2G 8x 32GB 2933 530-16i 8x 2.5" Any/24, 3x 7.68TB PM983+ 2x 240GB 5400 PRO Open 3x PCIe x8, 1x PCIe x16 2x 750W Yes Ent Slide
7X06A0FKNA 1x Silver 4216 16C 100W 2.1G 1x 32GB 2933 Option Option 24x 2.5", Open bay Open 2x PCIe x8 1x 750W Yes Ent Slide
7X06A0N8NA 1x Silver 4216 16C 100W 2.1G 1x 32GB 2933 Option Option 24x 2.5", Open bay Open 2x PCIe x8 1x 750W Yes Ent Slide
7X06A0FJNA 1x Gold 5217 8C 115W 3.0G 1x 32GB 2933 930-8i 8x 2.5" SAS/24, Open bay Open 2x PCIe x8 1x 750W Yes Ent Slide
7X06A0FDNA 1x Gold 5218 16C 125W 2.3G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS/24, Open bay Open 2x PCIe x8 1x 750W Yes Ent Slide
7X06A0FLNA 1x Gold 5218 16C 125W 2.3G 1x 32GB 2933 Option Option 24x 2.5", Open bay Open 2x PCIe x8 1x 750W Yes Ent Slide
7X06A0NANA 1x Gold 5218 16C 125W 2.3G 1x 32GB 2933 Option Option 24x 2.5", Open bay Open 2x PCIe x8 1x 750W Yes Ent Slide
7X06A0FFNA 1x Gold 5220 18C 125W 2.2G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS/24, Open bay Open 2x PCIe x8 1x 750W Yes Ent Slide
7X06100UNA 1x Gold 6208U 16C 150W 2.9G 2x 8GB 2933 Option Option 24x 2.5", Open bay 2x1Gb 5x PCIe x8 1x 1100W Opt Adv Slide
7X06100SNA 1x Gold 6230 20C 125W 2.1G 2x 8GB 2933 Option Option 3.5", Open bay 2x1Gb 2x PCIe x8 1x 1100W Opt Std Slide
7X06A0FBNA 1x Gold 6242 16C 150W 2.8G 1x 32GB 2933 930-8i 8x 2.5" SAS/24, Open bay Open 2x PCIe x8 1x 1100W Yes Ent Slide
7X06A0FANA 1x Gold 6248 20C 150W 2.5G 1x 32GB 2933 930-8i 8x 2.5" SAS/24, Open bay Open 2x PCIe x8 1x 1100W Yes Ent Slide
7X06A0GTNA 2x Gold 6248 20C 150W 2.5G 12x 32GB 2933 Option Option 24x 2.5", Open bay, 2x 128GB M.2 4x10Gb RJ45 3x PCIe x8, 3x PCIe x16
2x M10 GPU
2x 1600W Opt Ent Slide
7X06A0GXNA 2x Gold 6248 20C 150W 2.5G 12x 32GB 2933 Option Option 24x 2.5", Open bay, 2x 128GB M.2 4x10Gb RJ45 5x PCIe x8, 2x PCIe x16
4x T4 GPU
2x 1600W Opt Ent Slide
7X06A0H0NA 2x Gold 6248 20C 150W 2.5G 12x 32GB 2933 Option Option 24x 2.5", Open bay, 2x 128GB M.2 4x10Gb RJ45 3x PCIe x8, 3x PCIe x16
2x M10 GPU
2x 1600W Opt Ent Slide
7X06A0H1NA 2x Gold 6248 20C 150W 2.5G 12x 32GB 2933 Option Option 24x 2.5", Open bay, 2x 128GB M.2 4x10Gb RJ45 5x PCIe x8, 2x PCIe x16
4x T4 GPU
2x 1600W Opt Ent Slide
7X06A0F9NA 1x Gold 6252 24C 150W 2.1G 1x 32GB 2933 930-8i 8x 2.5" SAS/24, Open bay Open 2x PCIe x8 1x 1100W Yes Ent Slide
7X06100TNA 1x Platinum 8253 16C 125W 2.2G 2x 8GB 2933 Option Option 3.5", Open bay 2x1Gb 5x PCIe x8 1x 1100W Opt Adv Slide
7X06A0FCNA 1x Platinum 8260 24C 165W 2.4G 1x 32GB 2933 930-8i 8x 2.5" SAS/24, Open bay Open 2x PCIe x8 1x 1100W Yes Ent Slide
7X06A0FGNA 1x Platinum 8268 24C 205W 2.9G 1x 32GB 2933 930-8i 8x 2.5" SAS/24, Open bay Open 2x PCIe x8 1x 1100W Yes Ent Slide

† Processor description: Processor model, number of cores, thermal design power (TDP), core frequency

Processors

The SR650 server supports one or two Intel Xeon Bronze, Silver, Gold, or Platinum processors. The following table lists the specifications of the processors for the SR650 server.

Topics in this section:

Processor specifications

Processor support: Both 1st Gen and 2nd Gen Intel Xeon SP processors are supported. For supported 1st Gen processors, see the Continued support for 1st Gen Intel Xeon Scalable processors section.

Abbreviations used in the table:

  • UPI: Ultra Path Interconnect
  • TDP: Thermal Design Power
  • HT: Hyper-Threading
  • TB: Turbo Boost 2.0
  • VT-x: Virtualization Technology
  • VT-d: Virtualization Technology for Directed I/O
  • SST-PP: Speed Select Technology - Performance Profile
  • FMA: Fused-Multiply Add (AVX-512)
  • DCPMM: DC Persistent Memory Module
  • RAS: Reliability, Availability, and Serviceability
    • Std: Standard RAS
    • Adv: Advanced RAS
Table 13. Processor specifications
CPU
model
Cores /
threads
Core speed
(Base / TB Max)
Cache Max DDR4
speed
Max memory
capacity
per socket
UPI
speed
TDP
HT
TB
VT-x
VT-d
SST-PP
FMA units
DCPMM
RAS
Intel Xeon Bronze processors
3204 6 / 6 1.9 / 1.9 GHz 8.25 MB 2133 MHz 1 TB 9.6 GT/s 85 W N N Y Y N 1 N Std
3206R 8 / 8 1.9 / 1.9 GHz 11 MB 2133 MHz 1 TB 9.6 GT/s 85 W N N Y Y N 1 N Std
Intel Xeon Silver processors
4208 8 / 16 2.1 / 3.2 GHz 11 MB 2400 MHz 1 TB 9.6 GT/s 85 W Y Y Y Y N 1 N Std
4209T 8 / 16 2.2 / 3.2 GHz 11 MB 2400 MHz 1 TB 9.6 GT/s 70 W Y Y Y Y N 1 N Std
4210 10 / 20 2.2 / 3.2 GHz 13.75 MB 2400 MHz 1 TB 9.6 GT/s 85 W Y Y Y Y N 1 N Std
4210R 10 / 20 2.4 / 3.2 GHz 13.75 MB 2400 MHz 1 TB 9.6 GT/s 100 W Y Y Y Y N 1 N Std
4210T 10 / 20 2.3 / 3.2 GHz 13.75 MB 2400 MHz 1 TB 9.6 GT/s 95 W Y Y Y Y N 1 N Std
4214 12 / 24 2.2 / 3.2 GHz 16.5 MB 2400 MHz 1 TB 9.6 GT/s 85 W Y Y Y Y N 1 N Std
4214R 12 / 24 2.4 / 3.5 GHz 16.5 MB 2400 MHz 1 TB 9.6 GT/s 100 W Y Y Y Y N 1 N Std
4214Y 12 / 24 2.2 / 3.2 GHz 16.5 MB 2400 MHz 1 TB 9.6 GT/s 85 W Y Y Y Y Y 1 N Std
10 / 20 2.3 / 3.2 GHz
8 / 16 2.4 / 3.2 GHz
4215 8 / 16 2.5 / 3.5 GHz 11 MB 2400 MHz 1 TB 9.6 GT/s 85 W Y Y Y Y N 1 Y Std
4215R 8 / 16 3.2 / 4.0 GHz 11 MB 2400 MHz 1 TB 9.6 GT/s 130 W Y Y Y Y N 1 Y Std
4216 16 / 32 2.1 / 3.2 GHz 22 MB 2400 MHz 1 TB 9.6 GT/s 100 W Y Y Y Y N 1 N Std
Intel Xeon Gold processors
5215 10 / 20 2.5 / 3.4 GHz 13.75 MB 2666 MHz 1 TB 10.4 GT/s 85 W Y Y Y Y N 1 Y Adv
5215M 10 / 20 2.5 / 3.4 GHz 13.75 MB 2666 MHz 2 TB 10.4 GT/s 85 W Y Y Y Y N 1 Y Adv
5215L 10 / 20 2.5 / 3.4 GHz 13.75 MB 2666 MHz 4.5 TB 10.4 GT/s 85 W Y Y Y Y N 1 Y Adv
5217 8 / 16 3.0 / 3.7 GHz 11 MB 2666 MHz 1 TB 10.4 GT/s 115 W Y Y Y Y N 1 Y Adv
5218 16 / 32 2.3 / 3.9 GHz 22 MB 2666 MHz 1 TB 10.4 GT/s 125 W Y Y Y Y N 1 Y Adv
5218B 16 / 32 2.3 / 3.9 GHz 22 MB 2666 MHz 1 TB 10.4 GT/s 125 W Y Y Y Y N 1 Y Adv
5218R 20 / 40 2.1 / 4.0 GHz 27.5 MB 2666 MHz 1 TB 10.4 GT/s 125 W Y Y Y Y N 1 Y Adv
5218N 16 / 32 2.3 / 3.7 GHz 22 MB 2666 MHz 1 TB 10.4 GT/s 110 W Y Y Y Y N 1 Y Adv
5218T 16 / 32 2.1 / 3.8 GHz 22 MB 2666 MHz 1 TB 10.4 GT/s 105 W Y Y Y Y N 1 Y Adv
5220 18 / 36 2.2 / 3.9 GHz 24.75 MB 2666 MHz 1 TB 10.4 GT/s 125 W Y Y Y Y N 1 Y Adv
5220R 24 / 48 2.2 / 4.0 GHz 35.75 MB 2666 MHz 1 TB 10.4 GT/s 150 W Y Y Y Y N 1 Y Adv
5220S 18 / 36 2.7 / 3.9 GHz 24.75 MB 2666 MHz 1 TB 10.4 GT/s 125 W Y Y Y Y N 1 Y Adv
5220T 18 / 36 1.9 / 3.9 GHz 24.75 MB 2666 MHz 1 TB 10.4 GT/s 105 W Y Y Y Y N 1 Y Adv
5222 4 / 8 3.8 / 3.9 GHz 16.5 MB 2933 MHz 1 TB 10.4 GT/s 105 W Y Y Y Y N 2 Y Adv
6208U 16 / 32 2.9 / 3.9 GHz 22 MB 2933 MHz 1 TB No UPI 150 W Y Y Y Y N 2 Y Adv
6222V 20 / 40 1.8 / 3.6 GHz 27.5 MB 2400 MHz 1 TB 10.4 GT/s 115 W Y Y Y Y N 2 Y Adv
6226 12 / 24 2.7 / 3.7 GHz 19.25 MB 2933 MHz 1 TB 10.4 GT/s 125 W Y Y Y Y N 2 Y Adv
6226R 16 / 32 2.9 / 3.9 GHz 22 MB 2933 MHz 1 TB 10.4 GT/s 150 W Y Y Y Y N 2 Y Adv
6230 20 / 40 2.1 / 3.9 GHz 27.5 MB 2933 MHz 1 TB 10.4 GT/s 125 W Y Y Y Y N 2 Y Adv
6230N 20 / 40 2.3 / 3.9 GHz 27.5 MB 2933 MHz 1 TB 10.4 GT/s 125 W Y Y Y Y N 2 Y Adv
6230R 26 / 52 2.1 / 4.0 GHz 35.75 MB 2933 MHz 1 TB 10.4 GT/s 150 W Y Y Y Y N 2 Y Adv
6230T 20 / 40 2.1 / 3.9 GHz 27.5 MB 2933 MHz 1 TB 10.4 GT/s 125 W Y Y Y Y N 2 Y Adv
6234 8 / 16 3.3 / 4.0 GHz 24.75 MB 2933 MHz 1 TB 10.4 GT/s 130 W Y Y Y Y N 2 Y Adv
6238 22 / 44 2.1 / 3.7 GHz 30.25 MB 2933 MHz 1 TB 10.4 GT/s 140 W Y Y Y Y N 2 Y Adv
6238M 22 / 44 2.1 / 3.7 GHz 30.25 MB 2933 MHz 2 TB 10.4 GT/s 140 W Y Y Y Y N 2 Y Adv
6238L 22 / 44 2.1 / 3.7 GHz 30.25 MB 2933 MHz 4.5 TB 10.4 GT/s 140 W Y Y Y Y N 2 Y Adv
6238R 28 / 56 2.2 / 4.0 GHz 38.5 MB 2933 MHz 1 TB 10.4 GT/s 165 W Y Y Y Y N 2 Y Adv
6238T 22 / 44 1.9 / 3.7 GHz 30.25 MB 2933 MHz 1 TB 10.4 GT/s 125 W Y Y Y Y N 2 Y Adv
6240 18 / 36 2.6 / 3.9 GHz 24.75 MB 2933 MHz 1 TB 10.4 GT/s 150 W Y Y Y Y N 2 Y Adv
6240M 18 / 36 2.6 / 3.9 GHz 24.75 MB 2933 MHz 2 TB 10.4 GT/s 150 W Y Y Y Y N 2 Y Adv
6240L 18 / 36 2.6 / 3.9 GHz 24.75 MB 2933 MHz 4.5 TB 10.4 GT/s 150 W Y Y Y Y N 2 Y Adv
6240R 24 / 48 2.4 / 4.0 GHz 35.75 MB 2933 MHz 1 TB 10.4 GT/s 165 W Y Y Y Y N 2 Y Adv
6240Y 18 / 36 2.6 / 3.9 GHz 24.75 MB 2933 MHz 1 TB 10.4 GT/s 150 W Y Y Y Y Y 2 Y Adv
14 / 28 2.8 / 3.9 GHz
8 / 16 3.1 / 3.9 GHz
6242 16 / 32 2.8 / 3.9 GHz 22 MB 2933 MHz 1 TB 10.4 GT/s 150 W Y Y Y Y N 2 Y Adv
6242R 20 / 40 3.1 / 4.1 GHz 35.75 MB 2933 MHz 1 TB 10.4 GT/s 205 W Y Y Y Y N 2 Y Adv
6244 8 / 16 3.6 / 4.4 GHz 24.75 MB 2933 MHz 1 TB 10.4 GT/s 150 W Y Y Y Y N 2 Y Adv
6246 12 / 24 3.3 / 4.2 GHz 24.75 MB 2933 MHz 1 TB 10.4 GT/s 165 W Y Y Y Y N 2 Y Adv
6246R 16 / 32 3.4 / 4.1 GHz 35.75 MB 2933 MHz 1 TB 10.4 GT/s 205 W Y Y Y Y N 2 Y Adv
6248 20 / 40 2.5 / 3.9 GHz 27.5 MB 2933 MHz 1 TB 10.4 GT/s 150 W Y Y Y Y N 2 Y Adv
6248R 24 / 48 3.0 / 4.0 GHz 35.75 MB 2933 MHz 1 TB 10.4 GT/s 205 W Y Y Y Y N 2 Y Adv
6250 8 / 16 3.9 / 4.5 GHz 35.75 MB 2933 MHz 1 TB 10.4 GT/s 185 W Y Y Y Y N 2 Y Adv
6252 24 / 48 2.1 / 3.7 GHz 35.75 MB 2933 MHz 1 TB 10.4 GT/s 150 W Y Y Y Y N 2 Y Adv
6252N 24 / 48 2.3 / 3.6 GHz 35.75 MB 2933 MHz 1 TB 10.4 GT/s 150 W Y Y Y Y N 2 Y Adv
6254 18 / 36 3.1 / 4.0 GHz 24.75 MB 2933 MHz 1 TB 10.4 GT/s 200 W Y Y Y Y N 2 Y Adv
6256 12 / 24 3.6 / 4.5 GHz 33 MB 2933 MHz 1 TB 10.4 GT/s 205 W Y Y Y Y N 2 Y Adv
6258R 28 / 56 2.7 / 4.0 GHz 38.5 MB 2933 MHz 1 TB 10.4 GT/s 205 W Y Y Y Y N 2 Y Adv
6262V 24 / 48 1.9 / 3.6 GHz 33 MB 2400 MHz 1 TB 10.4 GT/s 135 W Y Y Y Y N 2 Y Adv
6271C* 24 / 48 2.6 / 3.9 GHz 33 MB 2666 MHz 1 TB 10.4 GT/s 165W Y Y Y Y N 2 Y Adv
Intel Xeon Platinum processors
8253 16 / 32 2.2 / 3.0 GHz 22 MB 2933 MHz 1 TB 10.4 GT/s 125 W Y Y Y Y N 2 Y Adv
8256 4 / 8 3.8 / 3.9 GHz 16.5 MB 2933 MHz 1 TB 10.4 GT/s 105 W Y Y Y Y N 2 Y Adv
8260 24 / 48 2.4 / 3.9 GHz 35.75 MB 2933 MHz 1 TB 10.4 GT/s 165 W Y Y Y Y N 2 Y Adv
8260M 24 / 48 2.4 / 3.9 GHz 35.75 MB 2933 MHz 2 TB 10.4 GT/s 165 W Y Y Y Y N 2 Y Adv
8260L 24 / 48 2.4 / 3.9 GHz 35.75 MB 2933 MHz 4.5 TB 10.4 GT/s 165 W Y Y Y Y N 2 Y Adv
8260Y 24 / 48 2.4 / 3.9 GHz 35.75 MB 2933 MHz 1 TB 10.4 GT/s 165 W Y Y Y Y Y 2 Y Adv
20 / 40 2.5 / 3.9 GHz
16 / 32 2.7 / 3.9 GHz
8268 24 / 48 2.9 / 3.9 GHz 35.75 MB 2933 MHz 1 TB 10.4 GT/s 205 W Y Y Y Y N 2 Y Adv
8270 26 / 52 2.7 / 4.0 GHz 35.75 MB 2933 MHz 1 TB 10.4 GT/s 205 W Y Y Y Y N 2 Y Adv
8276 28 / 56 2.2 / 4.0 GHz 38.5 MB 2933 MHz 1 TB 10.4 GT/s 165 W Y Y Y Y N 2 Y Adv
8276M 28 / 56 2.2 / 4.0 GHz 38.5 MB 2933 MHz 2 TB 10.4 GT/s 165 W Y Y Y Y N 2 Y Adv
8276L 28 / 56 2.2 / 4.0 GHz 38.5 MB 2933 MHz 4.5 TB 10.4 GT/s 165 W Y Y Y Y N 2 Y Adv
8280 28 / 56 2.7 / 4.0 GHz 38.5 MB 2933 MHz 1 TB 10.4 GT/s 205 W Y Y Y Y N 2 Y Adv
8280M 28 / 56 2.7 / 4.0 GHz 38.5 MB 2933 MHz 2 TB 10.4 GT/s 205 W Y Y Y Y N 2 Y Adv
8280L 28 / 56 2.7 / 4.0 GHz 38.5 MB 2933 MHz 4.5 TB 10.4 GT/s 205 W Y Y Y Y N 2 Y Adv

* Intel processor 6271C is only available in China

Configuration notes:

  • The Intel Xeon Gold 5218 and 5218B processors have similar specifications; however, they use different silicon designs and cannot be mixed in the same system.
  • Processors with a U suffix are only supported in single-processor configurations. This limits the PCIe slots that can be used.
  • The processors that support SST-PP offer three distinct operating points that are defined by a core count with a base speed associated with that core count. The operating point is static, it is selected during the boot process and cannot be changed at runtime.

Processor ordering information

For the SR650 server models that come standard with one processor, the second processor can be ordered, if required (see the following table for ordering information). The second processor must be of the same model as the first processor. The second processor option includes a processor and a heatsink; an additional system fan is not included and needs to be purchased with the second processor (see Cooling for details).

Table 14. Processor options
Part number Feature* Description
Intel Xeon Bronze processors
4XG7A37938 B4HU SR550/SR590/SR650 Intel Xeon Bronze 3204 6C 85W 1.9GHz Processor w/o FAN
4XG7A37983 B7N3 SR550/SR590/SR650 Intel Xeon Bronze 3206R 8C 85W 1.9GHz Processor w/o FAN
Intel Xeon Silver processors
4XG7A37935 B4HT SR550/SR590/SR650 Intel Xeon Silver 4208 8C 85W 2.1GHz Processor w/o FAN
4XG7A37944 B4P4 SR550/SR590/SR650 Intel Xeon Silver 4209T 8C 70W 2.2GHz Processor w/o FAN
4XG7A37932 B4HS SR550/SR590/SR650 Intel Xeon Silver 4210 10C 85W 2.2GHz Processor w/o FAN
4XG7A37981 B7N5 SR550/SR590/SR650 Intel Xeon Silver 4210R 10C 100W 2.4GHz Processor w/o FAN
4XG7A63276 BAZT SR650 Intel Xeon Silver 4210T 10C 95W 2.3GHz Processor w/o FAN
4XG7A37929 B4HR SR550/SR590/SR650 Intel Xeon Silver 4214 12C 85W 2.2GHz Processor w/o FAN
4XG7A37980 B7N6 SR550/SR590/SR650 Intel Xeon Silver 4214R 12C 100W 2.4GHz Processor w/o FAN
4XG7A37941 B4NW SR550/SR590/SR650 Intel Xeon Silver 4214Y 12/10/8C 85W 2.2GHz Processor w/o FAN
4XG7A37926 B4HQ SR550/SR590/SR650 Intel Xeon Silver 4215 8C 85W 2.5GHz Processor w/o FAN
4XG7A63274 BAZU SR590/SR650 Intel Xeon Silver 4215R 8C 130W 3.2GHz Processor w/o FAN
4XG7A37923 B4HP SR550/SR590/SR650 Intel Xeon Silver 4216 16C 100W 2.1GHz Processor w/o FAN
Intel Xeon Gold processors
4XG7A37916 B4HN SR550/SR590/SR650 Intel Xeon Gold 5215 10C 85W 2.5GHz Processor w/o FAN
4XG7A37913 B4P1 SR550/SR590/SR650 Intel Xeon Gold 5215M 10C 85W 2.5GHz Processor w/o FAN
4XG7A37910 B4P9 SR550/SR590/SR650 Intel Xeon Gold 5215L 10C 85W 2.5GHz Processor w/o FAN
4XG7A37919 B4HM SR550/SR590/SR650 Intel Xeon Gold 5217 8C 115W 3.0GHz Processor w/o FAN
4XG7A37895 B4HL SR550/SR590/SR650 Intel Xeon Gold 5218 16C 125W 2.3GHz Processor w/o FAN
4XG7A37958 B6BS SR550/SR590/SR650 Intel Xeon Gold 5218B 16C 125W 2.3GHz Processor w/o FAN
4XG7A63272 BAZS SR550/SR590/SR650 Intel Xeon Gold 5218R 20C 125W 2.1GHz Processor w/o FAN
4XG7A37955 B5S0 SR650 Intel Xeon Gold 5218N 16C 110W 2.3GHz Processor Option Kit w/o FAN
4XG7A38016 B4P3 SR550/SR590/SR650 Intel Xeon Gold 5218T 16C 105W 2.1GHz Processor w/o FAN
4XG7A37892 B4HK SR550/SR590/SR650 Intel Xeon Gold 5220 18C 125W 2.2GHz Processor w/o FAN
4XG7A37974 B7N9 SR590/SR650 Intel Xeon Gold 5220R 24C 150W 2.2GHz Processor w/o FAN
4XG7A38019 B6CW SR550/SR590/SR650 Intel Xeon Gold 5220S 18C 125W 2.7GHz Processor w/o FAN
4XG7A38005 B6CQ SR550/SR590/SR650 Intel Xeon Gold 5220T 18C 105W 1.9GHz Processor w/o FAN
4XG7A37951 B5S1 SR550/SR590/SR650 Intel Xeon Gold 5222 4C 105W 3.8GHz Processor w/o FAN
None** BAZV Intel Xeon Gold 6208U 16C 150W 2.9GHz Processor
4XG7A38023 B6CV SR550/SR590/SR650 Intel Xeon Gold 6222V 20C 115W 1.8GHz Processor w/o FAN
4XG7A38021 B6CL SR550/SR590/SR650 Intel Xeon Gold 6226 12C 125W 2.7GHz Processor w/o FAN
4XG7A38082 BAZW SR590/SR650 Intel Xeon Gold 6226R 16C 150W 2.9GHz Processor w/o FAN
4XG7A37889 B4HJ SR550/SR590/SR650 Intel Xeon Gold 6230 20C 125W 2.1GHz Processor w/o FAN
4XG7A38028 B5RY SR550/SR590/SR650 Intel Xeon Gold 6230N 20C 125W 2.3GHz Processor w/o FAN
4XG7A38081 BAZX SR590/SR650 Intel Xeon Gold 6230R 26C 150W 2.1GHz Processor w/o FAN
4XG7A38006 B6CP SR550/SR590/SR650 Intel Xeon Gold 6230T 20C 125W 2.1GHz Processor w/o FAN
4XG7A38001 B6CK SR590/SR650 Intel Xeon Gold 6234 8C 130W 3.3GHz Processor w/o FAN
4XG7A38008 B6CJ SR590/SR650 Intel Xeon Gold 6238 22C 140W 2.1GHz Processor w/o FAN
4XG7A37999 B6CM SR590/SR650 Intel Xeon Gold 6238M 22C 140W 2.1GHz Processor w/o FAN
4XG7A38003 B6CR SR590/SR650 Intel Xeon Gold 6238L 22C 140W 2.1GHz Processor w/o FAN
4XG7A38080 BAZL SR650 Intel Xeon Gold 6238R 28C 165W 2.2GHz Processor w/o FAN
4XG7A37906 B4P2 SR550/SR590/SR650 Intel Xeon Gold 6238T 22C 125W 1.9GHz Processor w/o FAN
4XG7A15895 B4HH SR650 Intel Xeon Gold 6240 18C 150W 2.6GHz Processor w/o FAN
4XG7A38013 B6CN SR590/SR650 Intel Xeon Gold 6240M 18C 150W 2.6GHz Processor w/o FAN
4XG7A38015 B6CS SR590/SR650 Intel Xeon Gold 6240L 18C 150W 2.6GHz Processor w/o FAN
4XG7A38079 BAZM SR650 Intel Xeon Gold 6240R 24C 165W 2.4GHz Processor w/o FAN
4XG7A37903 B4NV SR590/SR650 Intel Xeon Gold 6240Y 18/14/8C 150W 2.6GHz Processor w/o FAN
4XG7A37886 B4HG SR590/SR650 Intel Xeon Gold 6242 16C 150W 2.8GHz Processor w/o FAN
4XG7A38078 BAZN SR650 Intel Xeon Gold 6242R 20C 205W 3.1GHz Processor w/o FAN
4XG7A15874 B4HF SR590/SR650 Intel Xeon Gold 6244 8C 150W 3.6GHz Processor w/o FAN
4XG7A37963 B6PD SR650 Intel Xeon Gold 6246 12C 165W 3.3GHz Processor Option Kit w/o FAN
4XG7A38077 BAZP SR650 Intel Xeon Gold 6246R 16C 205W 3.4GHz Processor w/o FAN
4XG7A15892 B4HE SR650 Intel Xeon Gold 6248 20C 150W 2.5GHz Processor w/o FAN
4XG7A38076 BAZQ SR650 Intel Xeon Gold 6248R 24C 205W 3.0GHz Processor w/o FAN
4XG7A38075 B96C SR650 Intel Xeon Gold 6250 8C 185W 3.9GHz Processor w/o FAN
4XG7A15889 B4HC SR650 Intel Xeon Gold 6252 24C 150W 2.1GHz Processor w/o FAN
4XG7A38011 B6CT SR590/SR650 Intel Xeon Gold 6252N 24C 150W 2.3GHz Processor w/o FAN
4XG7A15872 B4HD SR650 Intel Xeon Gold 6254 18C 200W 3.1GHz Processor w/o FAN
4XG7A38074 B96D SR650 Intel Xeon Gold 6256 12C 205W 3.6GHz Processor w/o FAN
4XG7A38073 BAZR SR650 Intel Xeon Gold 6258R 28C 205W 2.7GHz Processor w/o FAN
4XG7A38010 B6CU SR590/SR650 Intel Xeon Gold 6262V 24C 135W 1.9GHz Processor w/o FAN
4XG7A86156 B4Q7 SR650 Intel Xeon Gold 6271C 24C 165W 2.6GHz Processor Option Kit w/o Fan (PRC only)
Intel Xeon Platinum processors
4XG7A37898 B5RZ SR550/SR590/SR650 Intel Xeon Platinum 8253 16C 125W 2.2GHz Processor w/o FAN
4XG7A37947 B5S2 SR550/SR590/SR650 Intel Xeon Platinum 8256 4C 105W 3.8GHz Processor w/o FAN
4XG7A15887 B4HB SR650 Intel Xeon Platinum 8260 24C 165W 2.4GHz Processor w/o FAN
4XG7A15885 B4NZ SR650 Intel Xeon Platinum 8260M 24C 165W 2.4GHz Processor w/o FAN
4XG7A15883 B4P7 SR650 Intel Xeon Platinum 8260L 24C 165W 2.4GHz Processor w/o FAN
4XG7A37901 B4NU SR650 Intel Xeon Platinum 8260Y 24/20/16C 165W 2.4GHz Processor w/o FAN
4XG7A15870 B4HA SR650 Intel Xeon Platinum 8268 24C 205W 2.9GHz Processor w/o FAN
4XG7A15868 B4H9 SR650 Intel Xeon Platinum 8270 26C 205W 2.7GHz Processor w/o FAN
4XG7A15881 B4H8 SR650 Intel Xeon Platinum 8276 28C 165W 2.2GHz Processor w/o FAN
4XG7A15879 B4NY SR650 Intel Xeon Platinum 8276M 28C 165W 2.2GHz Processor w/o FAN
4XG7A15877 B4P6 SR650 Intel Xeon Platinum 8276L 28C 165W 2.2GHz Processor w/o FAN
4XG7A15866 B4H7 SR650 Intel Xeon Platinum 8280 28C 205W 2.7GHz Processor w/o FAN
4XG7A15864 B4NX SR650 Intel Xeon Platinum 8280M 28C 205W 2.7GHz Processor w/o FAN
4XG7A15862 B4P5 SR650 Intel Xeon Platinum 8280L 28C 205W 2.7GHz Processor w/o FAN

* For CTO configurations, the feature code represents a processor, and fans and heatsinks are derived by the configuration tool.
** Factory-installed only; no field upgrade. Supported in the single-processor configurations only.

Configuration notes:

  • Processors with 200 W or 205 W TDP, or Gold 6230N, 6240Y, 6244, or 6250 processors are supported in the following hardware configurations and ambient temperature requirements:
    • 24x 2.5” chassis.
    • Ambient temperature and drive bay configurations:
      • Up to 35 °C (95 °F): 8x 2.5” SAS/SATA drive bays (drive backplane in the middle).
      • Up to 30 °C (86 °F):
        • 4x 2.5" SAS/SATA and 4x 2.5" AnyBay (up to 4 NVMe SSDs).
        • 8x 2.5" SAS/SATA and 8x 2.5" AnyBay (up to 8 NVMe SSDs).
      Note: Gold 6242R, 6246R, 6248R, 6250, 6256, and 6258R processors are supported only at the ambient temperature of up to 30 °C (86 °F) and only with 8x 2.5” SAS/SATA drive bays (drive backplane in the middle).
    • No rear HDD kit installed.
    • No PCIe flash adapters installed.
    • No GPU adapters installed, or up to four T4 GPU adapters installed.
    • The server performance might be impacted in case of a system fan failure.
  • Gold 6230T, 6246, or 6252N processors are supported in the following hardware configurations:
    • 8x 3.5" SAS/SATA drive bays.
    • 8x 2.5" SAS/SATA drive bays.
    • 4x 2.5" SAS/SATA and 4x 2.5" AnyBay drive bays.

Continued support for 1st Gen Intel Xeon Scalable processors

The SR650 also continues to support the 1st Gen Intel Xeon Scalable processors (formerly codenamed "Skylake") listed in the following table.

Table 15. Long-life 1st Gen Intel Xeon Scalable processors
Part number Feature code Description
7XG7A05570 AWEH ThinkSystem SR650 Intel Xeon Bronze 3106 8C 85W 1.7GHz Processor Option Kit
7XG7A05574 No CTO* ThinkSystem SR650 Intel Xeon Silver 4109T 8C 70W 2.0GHz Processor Option Kit
7XG7A05575 AWEE ThinkSystem SR650 Intel Xeon Silver 4110 8C 85W 2.1GHz Processor Option Kit
7XG7A05579 No CTO* ThinkSystem SR650 Intel Xeon Silver 4114T 10C 85W 2.2GHz Processor Option Kit
7XG7A05576 AWER ThinkSystem SR650 Intel Xeon Silver 4116 12C 85W 2.1GHz Processor Option Kit
7XG7A05573 AWEA ThinkSystem SR650 Intel Xeon Silver 4116T 12C 85W 2.1GHz Processor Option Kit
7XG7A05596 No CTO* ThinkSystem SR650 Intel Xeon Gold 5115 10C 85W 2.4GHz Processor Option Kit
7XG7A05580 AWEP ThinkSystem SR650 Intel Xeon Gold 5118 12C 105W 2.3GHz Processor Option Kit
7XG7A05581 No CTO* ThinkSystem SR650 Intel Xeon Gold 5119T 14C 85W 1.9GHz Processor Option Kit
7XG7A05582 AWE8 ThinkSystem SR650 Intel Xeon Gold 5120T 14C 105W 2.2GHz Processor Option Kit
7XG7A05590 AWEL ThinkSystem SR650 Intel Xeon Gold 6126 12C 125W 2.6GHz Processor Option Kit
7XG7A05589 AWE5 ThinkSystem SR650 Intel Xeon Gold 6126T 12C 125W 2.6GHz Processor Option Kit
7XG7A05587 AWEN ThinkSystem SR650 Intel Xeon Gold 6130 16C 125W 2.1GHz Processor Option Kit
7XG7A05586 AWE4 ThinkSystem SR650 Intel Xeon Gold 6130T 16C 125W 2.1GHz Processor Option Kit
7XG7A05605 No CTO* ThinkSystem SR650 Intel Xeon Gold 6134 8C 130W 3.2GHz Processor Option Kit
7XG7A05585 AWDZ ThinkSystem SR650 Intel Xeon Gold 6138 20C 125W 2.0GHz Processor Option Kit
7XG7A05584 AWEM ThinkSystem SR650 Intel Xeon Gold 6138T 20C 125W 2.0GHz Processor Option Kit
7XG7A05603 No CTO* ThinkSystem SR650 Intel Xeon Gold 6140 18C 140W 2.3GHz Processor Option Kit
7XG7A05601 No CTO* ThinkSystem SR650 Intel Xeon Gold 6142 16C 150W 2.6GHz Processor Option Kit
7XG7A05600 No CTO* ThinkSystem SR650 Intel Xeon Gold 6144 8C 150W 3.5GHz Processor Option Kit
7XG7A05599 No CTO* ThinkSystem SR650 Intel Xeon Gold 6146 12C 165W 3.2GHz Processor Option Kit
7XG7A05598 No CTO* ThinkSystem SR650 Intel Xeon Gold 6148 20C 150W 2.4GHz Processor Option Kit
7XG7A05597 No CTO* ThinkSystem SR650 Intel Xeon Gold 6150 18C 165W 2.7GHz Processor Option Kit
7XG7A05593 No CTO* ThinkSystem SR650 Intel Xeon Platinum 8153 16C 125W 2.0GHz Processor Option Kit
7XG7A05592 No CTO* ThinkSystem SR650 Intel Xeon Platinum 8156 4C 105W 3.6GHz Processor Option Kit
7XG7A05617 No CTO* ThinkSystem SR650 Intel Xeon Platinum 8158 12C 150W 3.0GHz Processor Option Kit
7XG7A05616 No CTO* ThinkSystem SR650 Intel Xeon Platinum 8160 24C 150W 2.1GHz Processor Option Kit
7XG7A05614 AWEK ThinkSystem SR650 Intel Xeon Platinum 8160T 24C 150W 2.1GHz Processor Option Kit
7XG7A05610 No CTO* ThinkSystem SR650 Intel Xeon Platinum 8176 28C 165W 2.1GHz Processor Option Kit
7XG7A05607 No CTO* ThinkSystem SR650 Intel Xeon Platinum 8180M 28C 205W 2.5GHz Processor Option Kit

* Only available as a field upgrade for existing customers. Not available in CTO (configure to order) configurations.

For specifications of these processors, see the Intel Xeon Scalable Processor Reference for Lenovo ThinkSystem Servers:
https://lenovopress.com/lp1262-intel-xeon-sp-processor-reference#term=SKL

Configuration note for 1st Gen processors: If processors with 200 W or 205 W TDP are used, or if Gold 6126T, 6144, or 6146, or Platinum 8160T processors are used, the following conditions must be met:

  • 24x 2.5” chassis only.
  • Ambient temperature and drive bay configurations:
    • Up to 35 °C (95 °F):
      • Except Gold 6137: 8x 2.5” SAS/SATA drive bays (drive backplane in the middle).
    • Up to 30 °C (86 °F):
      • Gold 6137 only: 8x 2.5” SAS/SATA drive bays (drive backplane in the middle).
      • Except Gold 6137:
        • 4x 2.5" SAS/SATA and 4x 2.5" AnyBay (up to 4 NVMe SSDs).
        • 8x 2.5" SAS/SATA and 8x 2.5" AnyBay (up to 8 NVMe SSDs).
  • No rear HDD kit installed.
  • No PCIe flash adapters installed.
  • No GPUs installed.
  • The server performance might be impacted in case of a fan failure.

UEFI operating modes

The SR650 offers preset operating modes that affect energy consumption and performance. These modes are a collection of predefined low-level UEFI settings that simplify the task of tuning the server to suit your business and workload requirements.

The following table lists the feature codes that allow you to specify the mode you wish to preset in the factory for CTO orders.

UK and EU customers: For compliance with the ERP Lot9 regulation, you should select feature BFYE. For some systems, you may not be able to make a selection, in which case, it will be automatically derived by the configurator.

Table 16. UEFI operating mode presets in DCSC
Feature code Description
BFYB Operating mode selection for: "Maximum Performance Mode"
BFYC Operating mode selection for: "Minimal Power Mode"
BFYD Operating mode selection for: "Efficiency Favoring Power Savings Mode"
BFYE Operating mode selection for: "Efficiency - Favoring Performance Mode"

The preset modes for the SR650 are as follows:

  • Maximum Performance Mode (feature BFYB): Achieves maximum performance but with higher power consumption and lower energy efficiency.
  • Minimal Power Mode (feature BFYC): Minimize the absolute power consumption of the system.
  • Efficiency Favoring Power Savings Mode (feature BFYD): Maximize the performance/watt efficiency with a bias towards power savings. This is the favored mode for SPECpower benchmark testing, for example.
  • Efficiency Favoring Performance Mode (feature BFYE): Maximize the performance/watt efficiency with a bias towards performance. This is the favored mode for Energy Star certification, for example.

For details about these preset modes, and all other performance and power efficiency UEFI settings offered in the SR650, see the paper "Tuning UEFI Settings for Performance and Energy Efficiency on Intel Xeon Scalable Processor-Based ThinkSystem Servers", available from https://lenovopress.lenovo.com/lp1477.

Memory

The SR650 server supports up to 12 TruDDR4 memory when one processor is installed and up to 24 DIMMs when two processors are installed. Each processor has six memory channels (two integrated memory controllers with three memory channels per memory controller), and there are two DIMMs per channel.

With 2nd Gen Xeon SP processors, the server supports memory up to 2933 MHz. With 1st Gen Xeon SP processors, the server supports memory up to 2666 MHz.

Lenovo TruDDR4 memory uses the highest-quality components sourced from Tier 1 DRAM suppliers and only memory that meets strict requirements is selected. It is compatibility tested and tuned on every ThinkSystem server to maximize performance and reliability. TruDDR4 memory has a unique signature programmed into the DIMM, which enables Lenovo servers to verify whether the memory installed is qualified and supported. Lenovo qualified and supported TruDDR4 memory is covered by Lenovo warranty, and service and support provided worldwide.

The following maximum memory capacities are supported by the server with 2nd Gen Xeon SP processors (up to 2933 MHz):

  • RDIMMs: 1.5 TB (768 GB per processor)
  • 3DS RDIMMs: 3 TB (1.5 TB per processor)

The following maximum memory capacities supported by the server with 1st Gen Xeon SP processors (up to 2666 MHz):

  • RDIMMs: 768 GB (384 GB per processor)
  • LRDIMMs: 1.5 TB (768 GB per processor)
  • 3DS RDIMMs: 3 TB (1.5 GB per processor)

The following memory protection technologies are supported by the processor's integrated memory controllers:

  • ECC
  • SDDC (for x4-based memory DIMMs)
  • ADDDC (for x4-based memory DIMMs; Gold and Platinum processors only)
  • Memory mirroring
  • Memory rank sparing
  • Patrol scrubbing
  • Demand scrubbing

The following table lists memory options are supported by the server. The table also indicates which processor generation is supported for each memory option.

Table 17. Memory options
Part
number
Feature
code
Description Maximum
quantity**
Gen 1
CPU
Gen 2
CPU
RDIMMs - 2933 MHz Performance+
4X77A12184 B5N6 ThinkSystem 16GB TruDDR4 Performance+ 2933MHz (2Rx8 1.2V) RDIMM 12 / 24 No Yes
4X77A12185 B5N7 ThinkSystem 32GB TruDDR4 Performance+ 2933MHz (2Rx4 1.2V) RDIMM 12 / 24 No Yes
4X77A12186 B5N8 ThinkSystem 64GB TruDDR4 Performance+ 2933MHz (2Rx4 1.2V) RDIMM 12 / 24 No Yes
RDIMMs - 2933 MHz
4ZC7A08706 B4H1 ThinkSystem 8GB TruDDR4 2933MHz (1Rx8 1.2V) RDIMM 12 / 24 No Yes
4ZC7A08707 B4LY ThinkSystem 16GB TruDDR4 2933MHz (1Rx4 1.2V) RDIMM 12 / 24 No Yes
4ZC7A08708 B4H2 ThinkSystem 16GB TruDDR4 2933MHz (2Rx8 1.2V) RDIMM 12 / 24 No Yes
4ZC7A08709 B4H3 ThinkSystem 32GB TruDDR4 2933MHz (2Rx4 1.2V) RDIMM 12 / 24 No Yes
4ZC7A08710 B4H4 ThinkSystem 64GB TruDDR4 2933MHz (2Rx4 1.2V) RDIMM 12 / 24 No Yes
3DS RDIMMs - 2933 MHz Performance+
4X77A12187 B5N9 ThinkSystem 128GB TruDDR4 Performance+ 2933MHz (4Rx4 1.2V) 3DS RDIMM 12 / 24 No Yes
3DS RDIMMs - 2933 MHz
4ZC7A15113 B587 ThinkSystem 128GB TruDDR4 2933MHz (4Rx4 1.2V) 3DS RDIMM 12 / 24 No Yes
RDIMMs - 2666 MHz
7X77A01301 AUU1 ThinkSystem 8GB TruDDR4 2666 MHz (1Rx8 1.2V) RDIMM 12 / 24 Yes No
7X77A01302 AUNB ThinkSystem 16GB TruDDR4 2666 MHz (1Rx4 1.2V) RDIMM 12 / 24 Yes Yes
7X77A01303 AUNC ThinkSystem 16GB TruDDR4 2666 MHz (2Rx8 1.2V) RDIMM 12 / 24 Yes Yes
7X77A01304 AUND ThinkSystem 32GB TruDDR4 2666 MHz (2Rx4 1.2V) RDIMM 12 / 24 Yes Yes
LRDIMMs - 2666 MHz
7X77A01305 AUNE ThinkSystem 64GB TruDDR4 2666 MHz (4Rx4 1.2V) LRDIMM 12 / 24 Yes No
3DS RDIMMs - 2666 MHz
4ZC7A08716 AUW5 ThinkSystem 64GB TruDDR4 2666MHz (4Rx4, 1.2V) 3DS RDIMM 12 / 24 No Yes
7X77A01307 AUNF ThinkSystem 128GB TruDDR4 2666 MHz (8Rx4 1.2V) 3DS RDIMM 12 / 24 Yes No

** The maximum quantity shown is with one processor / two processors.

Configuration notes:

  • All DIMMs in the server operate at the same speed, which is determined as the lowest value of:
    • DIMM rated speed (2666 MHz or 2933 MHz).
    • Memory speed supported by the specific processor (2133 MHz, 2400 MHz, 2666 MHz, or 2933 MHz).
    • Memory speed for the selected quantity of DIMMs per channel:
      • One DIMM per channel (1 DPC): 2933 MHz.
      • Two DIMMs per channel (2 DPC)
        • Performance+ DIMMs: 2933 MHz.
        • Other supported DIMMs: 2666 MHz.
    Note: Maximum memory speed can be achieved when Max performance mode is enabled in UEFI.
  • Mixing different types of memory (RDIMMs, LRDIMMs, 3DS RDIMMs) is not supported.
  • All Performance+ DIMMs in the server must be of the same type, rank, and capacity (the same part number or feature code) to operate at 2933 MHz in the configurations with two DIMMs per channel. Performance+ DIMMs cannot be mixed with other DIMMs. 
  • Mixing RDIMMs of different ranks (single- or dual-rank), DRAM chip types (x4 or x8), speeds (2666 MHz or 2933 MHz), and capacities (8 GB, 16 GB, 32 GB, or 64 GB) is supported in the independent channel mode (the default operational mode) (excluding Performance+ RDIMMs).
  • Mixing 3DS RDIMMs of different speeds (2666 MHz or 2933 MHz) and capacities (64 GB or 128 GB) is supported in the independent channel mode (excluding Performance+ 3DS RDIMMs).
  • The 128 GB Performance+ 2933 MHz 3DS RDIMMs (feature code B5N9) running at 2933 MHz with two DIMMs per channel are supported at the ambient temperature of up to 30 °C (86 °F).
  • The maximum quantity of DIMMs supported is reduced by the quantity of DC Persistent Memory Modules used in the configuration.
  • Server configurations with more than 1 TB of memory capacity per socket (including DCPMMs and RDIMMs or 3DS RDIMMs) require processors that support up to 2 TB (M-suffix) or 4.5 TB (L-suffix) per socket. Server configurations with more than 2 TB of memory capacity per socket (including DCPMMs and RDIMMs or 3DS RDIMMs) require processors that support up to 4.5 TB per socket (L-suffix).
  • For server configurations with memory protection, the following rules apply:
    • Single Device Data Correction (SDDC) works only in the independent channel mode and supports only x4-based memory DIMMs.
    • Adaptive Double Device Data Correction (ADDDC) works with x4-based memory DIMMs and requires two DIMM ranks per channel, Intel Xeon Gold or Platinum processors, and the Closed Page memory access mode.
    • If memory mirroring is used, then DIMMs must be installed in quantities of 2, 4, or 8 per processor for mirroring across two memory channels, or in quantities of 3, 6, 9, or 12 per processor for mirroring across three memory channels. Mixing two- and three-channel mirroring in the server is allowed (one processor uses two-channel mirroring, and another processor uses three-channel mirroring). All DIMMs in the server must be identical in type and size.
    • If memory rank sparing is used, then a minimum of two ranks must be installed per populated channel (a least one dual-rank or quad-rank DIMM, or two single-rank DIMMs). In rank sparing mode, one rank in each populated channel is reserved as spare memory for other ranks on the same channel. All DIMMs in the server must be identical in type and size.
    • SDDC, memory mirroring, and memory rank sparing modes are mutually exclusive. Only one operational memory mode can be enabled on the server.
    • In the configurations with DCPMMs, memory mirroring is supported only in the App Direct mode (other DCPMM modes do not support memory mirroring) and applies only to the RDIMMs or 3DS RDIMMs (DCPMMs are not mirrored). Memory sparing is not supported in the configurations with DCPMMs.

Persistent memory

Intel Optane DC persistent memory is an innovative technology that delivers a unique combination of affordable large memory capacity and persistence (non-volatility). The persistent memory technology can help boost the performance of data-intensive applications, such as in-memory analytics, databases, content delivery networks, and high performance computing (HPC), as well as deliver consistent service levels at scale with higher virtual machine and container density.

The SR650 server supports up to six TruDDR4 DC Persistent Memory Modules (DCPMMs) when one processor is installed and up to 12 DCPMMs when two processors are installed (up to one DCPMM per processor's memory channel) for a total of up to 6 TB of persistent memory capacity. The DCPMMs are installed in the same memory DIMM slots on the system board that are used for installing RDIMMs or 3DS RDIMMs.

2nd Gen processors only: Persistent Memory is only supported with 2nd Generation Intel Xeon SP processors. Not supported with 1st Generation processors.

The DCPMMs support the following modes of operation:

  • Memory Mode

    Memory Mode seamlessly brings large memory capacity at affordable cost points to legacy applications. In this mode, DCPMMs provide volatile memory that behaves much like traditional RDIMMs or 3DS RDIMMs (the data will not be saved in case of a power loss) and is transparent to the operating system and applications. DCPMMs provide memory capacity and RDIMMs or 3DS RDIMMs provide cache memory that is managed by the processor's memory controller. The total memory capacity that is seen by the operating system is the capacity of the DCPMMs; the capacity of the RDIMMs or 3DS RDIMMs is hidden and does not appear as a memory resource in the operating system. This mode is considered particularly suited for virtualized database deployments and big-data analytics applications.

  • App Direct Mode

    App Direct Mode brings persistency to the data and structures (the data will be saved in case of a power loss). This mode requires operating system and application awareness of two types of system memory: Persistent (DCPMMs) and DRAM (RDIMMs or 3DS RDIMMs). The total memory capacity that is seen by the operating system includes the capacity of the DCPMMs and RDIMMs or 3DS RDIMMs. This mode is considered particularly suited for in-memory databases, in-memory analytics frameworks, and ultrafast storage applications.

  • Mixed Memory Mode

    Mixed Memory Mode is a combination of Memory Mode and App Direct Mode, where a portion of the capacity of the DCPMMs is used for the Memory Mode operations, and the remaining capacity of the DCPMMs is used for the App Direct Mode operations.

The following memory protection technologies are supported by the DCPMM's onboard memory controllers:

  • ECC
  • SDDC
  • DDDC
  • Patrol scrubbing
  • Demand scrubbing

The following table lists DCPMM options available for the SR650 server.

Table 18. DCPMM options
Description Part number Feature code Maximum quantity*
ThinkSystem 128GB TruDDR4 2666MHz (1.2V) Intel Optane DC Persistent Memory 4ZC7A15110 B4LV 6 / 12
ThinkSystem 256GB TruDDR4 2666MHz (1.2V) Intel Optane DC Persistent Memory 4ZC7A15111 B4LW 6 / 12
ThinkSystem 512GB TruDDR4 2666MHz (1.2V) Intel Optane DC Persistent Memory 4ZC7A15112 B4LX 6 / 12

* The maximum quantity shown is with one processor / two processors.

The following table lists supported combinations of the DCPMMs and memory DIMMs available for the SR650 server.

Table 19. Supported DCPMM and memory DIMM combinations
DCPMM mode DCPMM
quantity*
Supported DCPMM sizes Memory DIMM
quantity*
Supported memory DIMM sizes
App Direct Mode - / 1 128 GB, 256 GB, 512 GB - / 12 16 GB, 32 GB, 64 GB, 128 GB
1 / 2 128 GB, 256 GB, 512 GB 6 / 12 16 GB, 32 GB, 64 GB, 128 GB
2 / 4 128 GB, 256 GB, 512 GB 4 / 8 16 GB, 32 GB, 64 GB, 128 GB
2 / 4 128 GB, 256 GB, 512 GB 6 / 12 16 GB, 32 GB, 64 GB, 128 GB
2 / 4 128 GB, 256 GB, 512 GB 8 / 16 16 GB, 32 GB, 64 GB, 128 GB
4 / 8 128 GB, 256 GB, 512 GB 6 / 12 16 GB, 32 GB, 64 GB, 128 GB
6 / 12 128 GB, 256 GB, 512 GB 6 / 12 16 GB, 32 GB, 64 GB, 128 GB
Memory Mode 2 / 4 128 GB 4 / 8 16 GB
2 / 4 256 GB 4 / 8 32 GB
2 / 4 512 GB 4 / 8 32 GB, 64 GB
2 / 4 256 GB 6 / 12 16 GB
2 / 4 512 GB 6 / 12 16 GB, 32 GB
4 / 8 128 GB 6 / 12 16 GB
4 / 8 256 GB 6 / 12 32 GB
4 / 8 512 GB 6 / 12 32 GB, 64 GB
6 / 12 128 GB 6 / 12 16 GB, 32 GB
6 / 12 256 GB 6 / 12 32 GB, 64 GB
6 / 12 512 GB 6 / 12 32 GB, 64 GB, 128 GB
Mixed Memory Mode 2 / 4 256 GB 6 / 12 16 GB
2 / 4 512 GB 6 / 12 16 GB, 32 GB
2 / 4 256 GB 4 / 8 16 GB
2 / 4 512 GB 4 / 8 16 GB, 32 GB
4 / 8 128 GB 6 / 12 16 GB
4 / 8 256 GB 6 / 12 16 GB, 32 GB
4 / 8 512 GB 6 / 12 16 GB, 32 GB, 64 GB
6 / 12 128 GB 6 / 12 16 GB
6 / 12 256 GB 6 / 12 16 GB, 32 GB
6 / 12 512 GB 6 / 12 16 GB, 32 GB, 64 GB

* The supported exact quantity shown is with one processor / two processors.

Configuration notes:

  • DCPMMs are supported only in the configurations with 8x 2.5-inch, 16x 2.5-inch, or 8x 3.5-inch drive bays.
  • All DCPMMs in the server must be of the same capacity (the same part number or feature code).
  • The RDIMMs or 3DS RDIMMs are required in the configurations with DCPMMs, and all RDIMMs or 3DS RDIMMs must be of the same type, rank, and capacity (the same part number or feature code).
  • The DCPMMs cannot be mixed with the 8GB TruDDR4 2933 MHz RDIMM (4ZC7A08706).
  • For Mixed Memory Mode, the volatile (Memory) portion of the total capacity of DCPMMs is configured in increments of 32 GB multiplied by the number of DCPMMs in the server, and the remaining capacity is allocated to the persistent (App Direct) portion. The ratio of the total capacity of RDIMMs or 3DS RDIMMs to the total capacity of the volatile portion of DCPMMs should be between 1 to 4 and 1 to 16.
  • Server configurations with more than 1 TB of memory capacity per socket (including DCPMMs and RDIMMs or 3DS RDIMMs) require processors that support up to 2 TB (M-suffix) or 4.5 TB (L-suffix) per socket. Server configurations with more than 2 TB of memory capacity per socket (including DCPMMs and RDIMMs or 3DS RDIMMs) require processors that support up to 4.5 TB per socket (L-suffix).
  • In the configurations with the processors of 200 W or 205 W TDP, or with Gold 6230N, 6240Y, 6244, or 6250 processors, the DCPMMs require two power supplies.
  • Persistent memory is not supported in configurations with GPU adapters
  • Persistent memory is not supported in configurations with flash storage adapters

For more information, refer to the Intel Optane DC Persistent Memory (DCPMM) Product Guide:
http://lenovopress.com/LP1066

Internal storage

Topics in this section:

Configurations

The SR650 server supports the following internal drive bay configurations:

  1. Up to 16 SFF (front) and 2 LFF (rear) hot-swap drive bays:
    1. 8x 2.5" SAS/SATA + 8x 2.5" SAS/SATA + 2x 3.5" SAS/SATA
    2. 4x 2.5" SAS/SATA & 4x 2.5" AnyBay + 8x 2.5" SAS/SATA + 2x 3.5" SAS/SATA
    3. 4x 2.5" SAS/SATA & 4x 2.5" AnyBay + 4x 2.5" SAS/SATA & 4x 2.5" AnyBay + 2x 3.5" SAS/SATA
  2. Up to 24 SFF (front) and 2 LFF (rear) hot-swap drive bays:
    1. 8x 2.5" SAS/SATA + 8x 2.5" SAS/SATA + 8x 2.5" SAS/SATA + 2x 3.5" SAS/SATA
    2. 4x 2.5" SAS/SATA & 4x 2.5" AnyBay + 8x 2.5" SAS/SATA + 8x 2.5" SAS/SATA + 2x 3.5" SAS/SATA
    3. 4x 2.5" SAS/SATA & 4x 2.5" AnyBay + 4x 2.5" SAS/SATA & 4x 2.5" AnyBay + 8x 2.5" SAS/SATA + 2x 3.5" SAS/SATA
    4. 4x 2.5" SAS/SATA & 4x 2.5" AnyBay + 4x 2.5" SAS/SATA & 4x 2.5" AnyBay + 4x 2.5" SAS/SATA & 4x 2.5" AnyBay
    5. 16x 2.5" U.2 NVMe PCIe + 8x 2.5" SAS/SATA (factory-installed only)
    6. 20x 2.5" U.2 NVMe PCIe
    7. 24x 2.5" U.2 NVMe PCIe
  3. Up to 10 LFF SAS/SATA hot-swap drive bays: 8x 3.5" SAS/SATA (front) + 2x 3.5" SAS/SATA (rear)
  4. Up to 14 LFF hot-swap drive bays:
    1. 12x 3.5" SAS/SATA (front) + 2x 3.5" SAS/SATA (rear)
    2. 8x 3.5" SAS/SATA & 4x 3.5" AnyBay (front) + 2x 3.5" SAS/SATA (rear)

In addition, the SR650 server models can be configured with one or two internal M.2 SATA SSDs. The server also supports configurations without drive bays.

The following figures show the internal drive bay configurations.

Drive bay configurations: 16x 2.5-inch chassis
Figure 8. Drive bay configurations: 16x 2.5-inch chassis

Drive bay configurations: 24x 2.5-inch chassis
Figure 9. Drive bay configurations: 24x 2.5-inch chassis

Drive bay configurations: 12x 3.5-inch chassis
Figure 10. Drive bay configurations: 12x 3.5-inch chassis

Backplanes

The following table lists the internal storage options for the server. For field upgrades, see the Field upgrades section.

Table 20. Backplanes for CTO orders
Feature code Description Maximum quantity
2.5-inch front drive backplanes
AURA ThinkSystem 2U/Twr 2.5" SATA/SAS 8-Bay Backplane 3
AUR5 ThinkSystem 2U/Twr 2.5" AnyBay 8-Bay Backplane 3
B4PC ThinkSystem 2U 2.5" NVMe 8-Bay Backplane 3
3.5-inch front drive backplanes
AUR6 ThinkSystem 2U 3.5" SATA/SAS 8-Bay Backplane 1
AUR9 ThinkSystem 2U 3.5" SATA/SAS 12-Bay Backplane 1
AUR8 ThinkSystem 2U 3.5" AnyBay 12-Bay Backplane 1
2x3.5-inch rear drive backplane kits (include two fans integrated into the drive bay assembly)
BMUW ThinkSystem SR590/SR650 Rear HDD/SSD Kit v2 (for X30 and X350 adapters, with either 2.5" or 3.5" chassis) 1
AURZ ThinkSystem SR590/SR650 Rear HDD/SSD Kit (for X30 and X350 adapters, with either 2.5" or 3.5" chassis) 1
BM7Q ThinkSystem BRCM SR650 Rear 3.5" HDD Kit (for X40 adapters, 2.5" chassis only) 1
BMAQ 2U Rear 3.5 HDD kit12X3.5 (for X40 adapters, 3.5" chassis only) 1
2x3.5-inch rear drive backplane kits (do not include integrated fans; available in the PRC market only)
BMXJ ThinkSystem SR590/SR650 Rear HDD Kit Without Fan v2 (for X30 and X350 adapters, with either 2.5" or 3.5" chassis) 1
BF6V ThinkSystem SR590/SR650 Rear HDD Kit Without Fan (for X30 and X350 adapters, with either 2.5" or 3.5" chassis) 1
BM7R ThinkSystem BRCM SR650 Rear 3.5" HDD Kit without Fan (for X40 adapters, 2.5" chassis only) 1
BMAP Rear HDD kit wo fan 12X3.5 (for X40 adapters, 3.5" chassis only) 1

Configuration notes:

  • 24x 2.5-inch front drives are supported only on storage dense models that use the 24x 2.5" chassis (feature code AUVV).
  • Processor TDP requirements:
    • Up to 3x 2.5" AnyBay 8-Bay Backplanes are supported in the server with the processors of up to 165 W TDP. 
    • Up to 2x 2.5" AnyBay 8-Bay Backplane Kits are supported in the server with the processors of more than 165 W TDP.
  • If 3x 2.5" AnyBay 8-Bay Backplane Kits are installed in the server, the Rear HDD kit cannot be installed.
  • For models with 16/20/24x 2.5" U.2 NVMe PCIe drive bays (either factory-installed or upgraded in the field), the following conditions must be met:
    • Two processors with up to 165 W TDP installed.
    • No GPU adapters installed.
    • No PCIe flash adapters installed.
    • No PCIe adapters with more than 25 W TDP installed.
    • 1100 W or 1600 W power supplies installed.
    • Ambient temperature of up to 30 °C (86 °F).
    • The server performance might be impacted in case of a system fan failure.

    For additional configuration details, refer to the Controllers for internal storage and I/O expansion sections.

  • The feature code for the 3.5" rear drive kit varies depending on which family of storage adapters (X30 or X40) is installed and which base chassis (2.5-inch or 3.5-inch) is selected.
  • The 3.5" rear drive bay feature codes (BMUW, AURZ, BM7Q, BMAQ) include two additional fans integrated into the drive bay assembly. For customers in China only, additional feature codes are also selectable and these do not include the fans (BMXJ, BF6V, BM7R, BMAP). The "without fans" feature codes can be used under the following conditions:
    • Processor TDP cannot exceed 125 W
    • Ambient temperature up to 30 °C (86 °F)
    • The acoustic noise may increase
  • The 3.5" rear drive kit is connected to a separate port on the internal storage controller.
  • The 3.5" rear drive kit is installed in place of the PCIe Riser Card 1; PCIe slots 1, 2, and 3 are not present.
  • Lenovo AnyBay allows a choice of drive interface types in the same drive bay: SAS drives, SATA drives, or NVMe PCIe drives.
  • U.2 NVMe PCIe SSDs in the 8/16/24-drive bay configurations that contain four AnyBay drive bays require either the second processor (enables the onboard NVMe controller) or the 1610-4P NVMe Switch Adapter to be installed. The 1610-4P NVMe Switch Adapter is supported only in the configurations with one processor.
  • Models with 12x 3.5-inch drive bays (8x SAS/SATA + 4x AnyBay) and an 8-port SAS RAID controller or HBA support only NVMe drives in the AnyBay drive bays.

Supported drive bay combinations

The following tables list supported internal storage configurations with the SAS/SATA and AnyBay backplanes.

Internal storage configurations tables convention: The numbers in brackets (x or x+y or x+y+z) in the Storage controller column specify the quantity of drive bays connected to each of the controllers.

Table 21. Internal storage configurations: Up to 16 SFF front drive bays without rear drive bays
Hot-swap drive bay
configuration
Backplane kit type and quantity Storage controller type and quantity (OB=onboard)
8x2.5"
SATA/
SAS
8x2.5"
Any
Bay
2x3.5"
Rear
HDD
16x 2.5" chassis (Feature code AUVX) or 24x 2.5" chassis (Feature code AUVV)
8x 2.5" SAS/SATA (front) 1 0 0 1x RAID 8i or HBA 8i (8)
1x RAID 16i/24i or HBA 16i (8)
4x 2.5" SAS/SATA (front) +
4x 2.5" AnyBay (front)
0 1 0 1x RAID 8i or HBA 8i (8) + 1x OB or 1610-4P NVMe (4)
1x RAID 16i/24i or HBA 16i (8) + 1x OB or 1610-4P NVMe (4)
16x 2.5" SAS/SATA (front) 2 0 0 1x RAID 16i/24i or HBA 16i (16)
1x RAID 8i (8) + 1x HBA 8i (8)
2x RAID 8i or 2x HBA 8i (8+8)
12x 2.5" SAS/SATA (front) +
4x 2.5" AnyBay
 (front)
1 1 0 1x RAID 16i/24i or HBA 16i (16) + 1x OB or 1610-4P NVMe (4)
8x 2.5" SAS/SATA (front) +
8x 2.5" AnyBay
 (front)
0 2 0 1x RAID 16i/24i or HBA 16i (16) + 1x OB NVMe (4) + 1x 1610-4P NVMe (4)
2x RAID 8i or HBA 8i (8+8) + 1x OB NVMe (4) + 1x 1610-4P NVMe (4)
1x RAID 16i (16) + 1x 1611-8P (8)
Table 22. Internal storage configurations: Up to 16 SFF front and 2 LFF rear drive bays
Hot-swap drive bay
configuration
Backplane kit type and quantity Storage controller type and quantity (OB=onboard)
8x2.5"
SATA/
SAS
8x2.5"
Any
Bay
2x3.5"
Rear
HDD
16x 2.5" chassis (Feature code AUVX) or 24x 2.5" chassis (Feature code AUVV)
8x 2.5" SAS/SATA (front) +
2x 3.5" SAS/SATA (rear)
1 0 1 1x RAID 16i/24i or HBA 16i (10)
1x RAID 8i (8) + 1x RAID 8i or HBA 8i (2)
1x 430-8i HBA (8) + 1x RAID 530-8i (2)
2x RAID 8i or HBA 8i (8+2)
4x 2.5" SAS/SATA (front) +
4x 2.5" AnyBay (front) +
2x 3.5" SAS/SATA (rear)
0 1 1 1x RAID 8i or HBA 8i (8) + 1x OB/1610-4P NVMe (4) + 1x RAID 8i or HBA 8i (2)
1x RAID 16i/24i or HBA 16i (10) + 1x OB/1610-4P NVMe (4)
16x 2.5" SAS/SATA (front) +
2x 3.5" SAS/SATA (rear)
2 0 1 1x RAID 16i or HBA 16i (16) + 1x RAID 8i or HBA 8i (2)
1x RAID 930-24i (18)
3x RAID 8i or HBA 16i (8+8+2)
12x 2.5" SAS/SATA (front) +
4x 2.5" AnyBay (front) +
2x 3.5" SAS/SATA (rear)
1 1 1 1x RAID 16i or HBA 16i (16) + 1x OB/1610-4P NVMe (4) + 1x RAID 8i or HBA 8i (2)
1x RAID 24i (18) + 1x OB/1610-4P NVMe (4)
8x 2.5" SAS/SATA (front) +
8x 2.5" AnyBay
 (front) +
2x 3.5" SAS/SATA (rear)
0 2 1 1x RAID 16i or HBA 16i (16) + 1x OB NVMe (4) + 1x 1610-4P NVMe (4) + 1x RAID 8i or HBA 8i (2)
1x RAID 24i (18) + 1x OB NVMe (4) + 1x 1610-4P NVMe (4)
2x RAID 8i or HBA 8i (8+8) + 1x Onboard NVMe (4) + 1x 1610-4P NVMe (4) + 1x RAID 8i or HBA 8i (2)
Table 23. Internal storage configurations: Up to 24 SFF front drive bays without rear drive bays
Hot-swap drive bay
configuration
Backplane kit type and quantity Storage controller type and quantity (OB=onboard)
8x2.5"
SATA/
SAS
8x2.5"
Any
Bay
8x2.5"
NVMe
2x3.5"
Rear
HDD
24x 2.5" chassis (Feature code AUVV)
24x 2.5" SAS/SATA (front) 3 0 0 0 1x RAID 24i (24)
1x RAID 8i (8) + 1x RAID 16i (16)
3x RAID 8i or 3x HBA 8i (8+8+8)
20x 2.5" SAS/SATA (front) +
4x 2.5" AnyBay
 (front)
2 1 0 0 1x RAID 24i (24) + 1x OB/1610-4P NVMe (4)
1x RAID 8i (8) + 1x RAID 16i (16) + 1x OB/1610-4P NVMe (4)
3x RAID 8i or HBA 8i (8+8+8) + 1x Onboard/1610-4P NVMe (4)
16x 2.5" SAS/SATA (front) +
8x 2.5" AnyBay
 (front)
1 2 0 0 1x RAID 24i (24) + 1x OB NVMe (4) + 1x 1610-4P NVMe (4)
3x RAID 8i (8+8+8) + 1x OB NVMe (4) + 1x 1610-4P NVMe (4)
1x HBA 8i (8) + 1x HBA 16i (16) + 1x OB NVMe (4) + 1x 1610-4P NVMe (4)
1x RAID 32i (24) + 1x 1611-8P (8)
1x RAID 16i (16) + 1x RAID 8i (8) + 1x 1611-8P (8)
12x 2.5" SAS/SATA (front) +
12x 2.5" AnyBay (front)
0 3 0 0 1x RAID 24i (24) + 1x OB NVMe (4) + 2x 1610-4P NVMe (4+4)
3x RAID 8i or HBA 8i (8+8+8) + 1x OB NVMe (4) + 2x 1610-4P NVMe (4+4)
1x HBA 8i (8) + 1x HBA 16i (16) + 1x OB NVMe (4) + 2x 1610-4P NVMe (4+4)
1x RAID 32i (24) + 1x OB NVMe (4) + 1x 1611-8P (8)
1x RAID 16i (16) + 1x RAID 8i (8) + 1x OB NVMe (4) + 1x 1611-8P (8)
16x 2.5" U.2 NVMe (front) 0 0 2 0 2x 810-4P NVMe (4+4) + 2x 1610-4P NVMe (4+4)
2x 1611-8P (8+8)
16x 2.5" U.2 NVMe (front) +
8x 2.5" SAS/SATA (front)
1 0 2 0 1x RAID/HBA 8i (8) + 2x 810-4P NVMe (4+4) + 2x 1610-4P NVMe (4+4)
1x RAID 8i (8) + 2x 1611-8P (8+8)
20x 2.5" U.2 NVMe (front) 0 0 3 0 1x Onboard NVMe (4) + 2x 810-4P NVMe (4+4) + 3x 1610-4P NVMe (4+4+4)
24x 2.5" U.2 NVMe (front) 0 0 3 0 4x 810-4P NVMe (4+4+4+4) + 1x 1610-8P NVMe (8)
3x 1611-8P (8+8+8)
Table 24. Internal storage configurations: Up to 24 SFF front and 2 LFF rear drive bays
Hot-swap drive bay
configuration
Backplane kit type and quantity Storage controller type and quantity (OB=onboard)
8x2.5"
SATA/
SAS
8x2.5"
Any
Bay
2x3.5"
Rear
HDD
24x 2.5" chassis (Feature code AUVV)
24x 2.5" SAS/SATA (front) +
2x 3.5" SAS/SATA (rear)
3 0 1 1x RAID 24i (24) + 1x RAID 8i or HBA 8i (2)
1x RAID 8i or HBA 8i (8) + 1x RAID 16i or HBA 16i (16) + 1x RAID 8i or HBA 8i (2)
2x RAID 16i or HBA 16i (16+10)
2x HBA 16i (8+2) + 1x HBA 16i (16)
3x RAID 8i or HBA 8i (8+8+8) + 1x RAID 8i or HBA 8i(2)
20x 2.5" SAS/SATA (front) +
4x 2.5" AnyBay
 (front) +
2x 3.5" SAS/SATA (rear)
2 1 1 1x RAID 24i (24) + 1x OB/1610-4P NVMe (4) + 1x RAID 8i or HBA 8i (2)
1x RAID 8i (8) + 1x RAID 16i (16) + 1x OB/1610-4P NVMe (4) + 1x RAID 8i or HBA 8i (2)
2x RAID 16i or HBA 16i (16+10) + 1x OB/1610-4P NVMe (4)
3x RAID 8i or HBA 8i (8+8+8) + 1x OB/1610-4P NVMe (4) + 1x RAID 8i or HBA 8i (2)
16x 2.5" SAS/SATA (front) +
8x 2.5" AnyBay
 (front) +
2x 3.5" SAS/SATA (rear)
1 2 1 1x RAID 24i (24) + 1x OB NVMe (4) + 1x 1610-4P NVMe (4) + 1x RAID 8i (2)
1x HBA 8i (8) + 1x HBA 16i (16) + 1x OB NVMe (4) + 1x 1610-4P NVMe (4) + 1x RAID 8i (2)
2x RAID 16i (16+10) + 1x OB NVMe (4) + 1x 1610-4P NVMe (4)
2x HBA 8i (8+2) + 1x HBA 16i (16) + 1x OB NVMe (4) + 1x 1610-4P NVMe (4)
2x 16i HBA (16+10) + 1x OB NVMe (4) + 1x 1610-4P NVMe (4)
Table 25. Internal storage configurations: Up to 12 LFF front and 2 LFF rear drive bays
Hot-swap drive bay
configuration
Backplane kit type and quantity Storage controller type and quantity
8x3.5"
SATA/
SAS
12x3.5"
SATA/
SAS
12x3.5"
Any
Bay
2x3.5"
Rear
HDD
12x 3.5" chassis (Feature code AUVW)
8x 3.5" SAS/SATA (front) 1 0 0 0 1x RAID 16i (8)
1x RAID 8i or HBA 8i (8)
8x 3.5" SAS/SATA (front) +
2x 3.5" SAS/SATA (rear)
1 0 0 1 1x RAID 16i or HBA 16i (10)
1x RAID 8i or HBA 8i (8) + 1x RAID 8i or HBA 8i (2)
1x RAID 16i (8) + 1x RAID 8i (2)
2x RAID 8i or HBA 8i (8+2)
12x 3.5" SAS/SATA (front) 0 1 0 0 1x RAID 16i or HBA 16i (12)
8x 3.5" SAS/SATA (front) +
4x 3.5" AnyBay
 (front)
0 0 1 0 1x RAID 16i or HBA 16i (12) + 1x OB/1610-4P NVMe (4)
8x 3.5" SAS/SATA (front) +
4x 3.5" AnyBay (NVMe only) (front)*
0 0 1 0 1x RAID 8i or HBA 8i (8) + 1x OB/1610-4P NVMe (4)
12x 3.5" SAS/SATA (front) +
2x 3.5". SAS/SATA (rear)
0 1 0 1 1x RAID 16i or HBA 16i (14)
1x RAID 16i or HBA 16i (12) + 1x RAID 8i (2)
8x 3.5" SAS/SATA (front) +
4x 3.5" AnyBay (front) +
2x 3.5" SAS/SATA (rear)
0 0 1 1 1x RAID 16i or HBA 16i (14) + 1x OB/1610-4P NVMe (4)

* Four NVMe SSDs are required in the 3.5" AnyBay configuration with an 8-port storage controller.

12-drive AnyBay 3.5-inch configuration with expander (PRC only)

In addition to the configurations described above, the SR650 server also supports internal storage configurations with the 3.5" AnyBay 12-Bay Backplane w/Expander to enable support for up to 12 SAS or SATA drives with the 8-port RAID 530/730/930-8i controllers.

China customers only: Internal storage configurations with the 3.5" AnyBay 12-Bay Backplane w/Expander and 8-port RAID 530/730/930-8i controllers are available in PRC only.

The following table lists the 3.5" AnyBay 12-Bay Backplane w/Expander for the SR650 server.

Table 26. 3.5" AnyBay 12-Bay Backplane w/Expander
Part number Feature code Description Maximum quantity
None* BD3Q ThinkSystem SR650 3.5" AnyBay 12-Bay Backplane w/Expander 1

* The backplane kit can be factory-installed in standard or custom (CTO or Special Bid) models, and it does not have an option part number assigned.

Configuration notes:

  • The 3.5" AnyBay 12-Bay Backplane w/Expander provides 8x 3.5" SAS/SATA (front) + 4x 3.5" AnyBay (front) drive bays.
  • The following 8-port RAID adapters are supported in the configurations with the 3.5" AnyBay 12-Bay Backplane w/Expander:
    • RAID 530-8i
    • RAID 730-8i 1GB
    • RAID 730-8i 2GB
    • RAID 930-8i 2GB
  • The onboard NVMe interface provides 4x PCIe 3.0 x4 ports for JBOD (non-RAID) connectivity to NVMe PCIe SSDs in the AnyBay drive bays.

Field upgrades

The following table lists the backplane options that can be installed as field upgrades.

Use with X40 adapters: These backplane kits in the table below include SAS/SATA cables for use with the onboard SATA controller or with RAID 930, 730, 530 adapters and 430 HBAs (collectively called X30 adapters). If you are adding or upgrading to RAID 940 adapters or 440 HBAs (collectively called X40 adapters), you will need to also order an X40 cable kit. See the Cable kits for 440 HBAs and RAID 940 adapters section for details.

Use with the 1611-8P adapter: AnyBay and NVMe backplane kits in the table below include NVMe cables for use with 1610-4P or 810-4P NVMe adapters. If you are adding or upgrading to the 1611-8P NVMe adapter, you will need to also order 1611-8P Cable Kit. See the Cable kit for the 1611-8P adapter section for details.

Table 27. Drive bay field upgrades
Part number Description Maximum quantity
2.5-inch front drive bays
7XH7A06254 ThinkSystem SR550/SR650 2.5" SATA/SAS 8-Bay Backplane Kit 3
7XH7A06251 ThinkSystem SR650 2.5" AnyBay 8-Bay Backplane Kit 3
4XH7A09819 ThinkSystem SR650 U.2 20-Bays Upgrade Kit 1
4XH7A08810 ThinkSystem SR650 U.2 24-Bays Upgrade Kit 1
3.5-inch front drive bays
4XH7A08770 ThinkSystem SR550/SR590/SR650 3.5" SATA/SAS 8-Bay Backplane Upgrade Kit 1
4XH7A08771 ThinkSystem SR550/SR590/SR650 3.5" SATA/SAS 12-Bay Backplane Upgrade Kit 1
4XH7A08785 ThinkSystem SR590/SR650 3.5" AnyBay 12-Bay Backplane Upgrade Kit 1
2x3.5-inch rear drive bays
4XH7A80453 ThinkSystem SR590/SR650 Rear HDD/SSD Kit v2 1
7XH7A06253 ThinkSystem SR590/SR650 Rear HDD/SSD Kit 1
4XB7A64318 ThinkSystem SR590/SR650 Rear HDD Kit Without Fan (PRC only) 1

Configuration notes:

  • The SAS/SATA and AnyBay backplane upgrade kits include drive backplanes and required SAS cables, NVMe cables, power cables, and drive bay fillers; storage controllers are not included.
  • The 2.5" SATA/SAS 8-Bay Backplane Kit (7XH7A06254) adds 8x 2.5" SAS/SATA hot-swap drive bays to the previously configured models that are based on the 16x 2.5" chassis (feature code AUVX) or 24x 2.5" chassis (feature code AUVV) and support drive bay expansion capabilities (including models without drive bays).
  • The 2.5" AnyBay 8-Bay Backplane Kit (7XH7A06251) adds 4x 2.5" SAS/SATA & 4x 2.5" AnyBay hot-swap drive bays to the previously configured models that are based on the 16x 2.5" chassis (feature code AUVX) or 24x 2.5" chassis (feature code AUVV) and support drive bay expansion capabilities (including models without drive bays).
  • Processor TDP requirements:
    • Up to 3x 2.5" AnyBay 8-Bay Backplanes are supported in the server with the processors of up to 165 W TDP. 
    • Up to 2x 2.5" AnyBay 8-Bay Backplane Kits are supported in the server with the processors of more than 165 W TDP.
  • If 3x 2.5" AnyBay 8-Bay Backplane Kits are installed in the server, the Rear HDD kit cannot be installed.
  • Models without any drive bays that are based on the 12x 3.5" chassis (feature code AUVW) include the Right EIA Latch with FIO (USB ports, status LEDs, and a power button). These models support adding drive bays by using the 3.5" 8-bay backplane kit (4XH7A08770), 3.5" 12-bay backplane kit (4XH7A08771), or 3.5" AnyBay 12-bay backplane kit (4XH7A08785).
  • Previously configured models that are based on the 24x 2.5" chassis (feature code AUVV) can be upgraded to 20 or 24 U.2 NVMe PCIe drive bays by using the U.2 NVMe 20-Bay Backplane Upgrade Kit (4XH7A09819) or U.2 NVMe 24-Bay Backplane Upgrade Kit (4XH7A08810), respectively. Both kits include drive backplanes and required NVMe cables, power cables, drive bay fillers, and NVMe switch adapters. The U.2 NVMe 24-Bay Backplane Upgrade Kit also includes the x16/x8/x16 Riser Card 1 (4XH7A09902).
  • For models with 16/20/24x 2.5" U.2 NVMe PCIe drive bays (either factory-installed or upgraded in the field), the following conditions must be met:
    • Two processors with up to 165 W TDP installed.
    • No GPU adapters installed.
    • No PCIe flash adapters installed.
    • No PCIe adapters with more than 25 W TDP installed.
    • 1100 W or 1600 W power supplies installed.
    • Ambient temperature of up to 30 °C (86 °F).
    • The server performance might be impacted in case of a system fan failure.

    Note: For additional configuration details, refer to the Controllers for internal storage and I/O expansion sections.

  • The Rear drive bay kits (4XH7A80453 and 7XH7A06253) include two additional fans integrated into the drive bay assembly. For customers in China, the ThinkSystem SR590/SR650 Rear HDD Kit Without Fan (4XB7A64318) is also available and does not include the fans. The Rear HDD Kit Without Fan can be used under the following conditions:
    • Processor TDP cannot exceed 125 W
    • Ambient temperature up to 30 °C (86 °F)
    • The acoustic noise may increase
  • The 3.5" Rear HDD/SSD Kit is connected to a separate port on the internal storage controller.
  • The 3.5" Rear HDD/SSD Kit is installed in place of the PCIe Riser Card 1; PCIe slots 1, 2, and 3 are not present.
  • U.2 NVMe PCIe SSDs in the 8/16/24-drive bay configurations that contain four AnyBay drive bays require either the second processor (enables the onboard NVMe controller) or the 1610-4P NVMe Switch Adapter to be installed. The 1610-4P NVMe Switch Adapter is supported only in the configurations with one processor.
  • Models with 12x 3.5-inch drive bays (8x SAS/SATA + 4x AnyBay) and an 8-port SAS RAID controller or HBA support only NVMe drives in the AnyBay drive bays.

Cable kits for 440 HBAs and RAID 940 adapters

The backplane kits listed in the Drive bay field upgrades table include cables for use with the onboard SATA controller or with RAID 930, 730, 530 adapters and 430 HBAs (collectively called X30 adapters). If you wish to use the backplane kits with RAID 940 adapters or 440 HBAs (collectively called X40 adapters), then you will also need to order an additional X40 cable kit to use instead of the cables in the backplane kit.

Tip: When adding an X40 adapter, you will order both the backplane kit and the relevant X40 cable kit, however the SAS/SATA data cable(s) in the backplane kit will not be used.

Table 28. Cable kits for 440 HBAs and RAID 940 adapters
Backplane kits with X30 cables X40 cable kits also needed (1 per backplane)
7XH7A06254 ThinkSystem SR550/SR650 2.5" SATA/SAS 8-Bay Backplane Kit 4XH7A61097 ThinkSystem SR550/SR590/SR650 2.5" SAS/SATA/AnyBay 8-Bay X40 RAID Cable Kit
7XH7A06251 ThinkSystem SR650 2.5" AnyBay 8-Bay Backplane Kit 4XH7A61097 ThinkSystem SR550/SR590/SR650 2.5" SAS/SATA/AnyBay 8-Bay X40 RAID Cable Kit
4XH7A08770 ThinkSystem SR550/SR590/SR650 3.5" SATA/SAS 8-Bay Backplane Upgrade Kit 4XH7A61098 ThinkSystem SR550/SR590/SR650 3.5" SAS/SATA 8-Bay X40 RAID Cable Kit
4XH7A08771 ThinkSystem SR550/SR590/SR650 3.5" SATA/SAS 12-Bay Backplane Upgrade Kit 4XH7A61105 ThinkSystem SR590/SR650 3.5" SAS/SATA/AnyBay 12-Bay X40 RAID Cable Kit
4XH7A08785 ThinkSystem SR590/SR650 3.5" AnyBay 12-Bay Backplane Upgrade Kit 4XH7A61105 ThinkSystem SR590/SR650 3.5" SAS/SATA/AnyBay 12-Bay X40 RAID Cable Kit
4XH7A09819 ThinkSystem SR650 U.2 20-Bays Upgrade Kit None Not needed - NVMe only
4XH7A08810 ThinkSystem SR650 U.2 24-Bays Upgrade Kit None Not needed - NVMe only
7XH7A06253 ThinkSystem SR590/SR650 Rear HDD/SSD Kit 4XH7A61110 ThinkSystem SR590/SR630/SR650 SAS/SATA 2-Bay Rear BP X40 RAID Cable Kit
4XB7A64318 ThinkSystem SR590/SR650 Rear HDD Kit Without Fan (PRC only) 4XH7A61110 ThinkSystem SR590/SR630/SR650 SAS/SATA 2-Bay Rear BP X40 RAID Cable Kit

Cable kit for the 1611-8P adapter

The backplane kit part numbers listed in the Drive bay field upgrades table that include NVMe connections (that is, NVMe backplanes and AnyBay backplanes) only include cables for use with 1610-4P or 810-4P NVMe adapters. If you wish to use these backplane kits with the 1611-8P NVMe adapter, then you will also need to order an additional cable kit to use instead of the cables in the backplane kit.

Tip: When adding an 1611-8P adapter, you will order both the backplane kit and the 1611-8P cable kit, however the NVMe data cables in the backplane kit will not be used.

Table 29. Cable kit for 1611-8P adapter
Part number Description
4X97A83642 ThinkSystem SR650 1611-8P NVMe Switch Adapter Cable Kit

M.2 drives

The server supports one or two M.2 form-factor SATA drives for use as an operating system boot solution. With two M.2 drives configured, the drives are configured by default as a RAID-1 mirrored pair for redundancy.

The M.2 drives install into an M.2 adapter which in turn is installed in a dedicated slot on the system board. See the internal view of the server in the Components and connectors section for the location of the M.2 slot.

There are two M.2 adapters supported, as listed in the following table.

Table 30. M.2 components
Part number Feature code Description Maximum
supported
7Y37A01092 AUMU ThinkSystem M.2 Enablement Kit
(contains the Single M.2 Boot Adapter; supports 1 drive)
1
7Y37A01093 AUMV ThinkSystem M.2 with Mirroring Enablement Kit
(contains the Dual M.2 Boot Adapter, supports 1 or 2 drives)
1

Supported drives are listed in the Internal drive options section.

For details about M.2 components, see the ThinkSystem M.2 Drives and M.2 Adapters product guide:
https://lenovopress.com/lp0769-thinksystem-m2-drives-adapters

SED encryption key management with SKLM

The server supports self-encrypting drives (SEDs) as listed in the Internal drive options section. To effectively manage a large deployment of these drives in Lenovo servers, IBM Security Key Lifecycle Manager (SKLM) offers a centralized key management solution.

A Lenovo Feature on Demand (FoD) upgrade is used to enable this SKLM support in the management processor of the server. The following table lists the part numbers and feature codes for the upgrades.

Table 31. FoD upgrades for SKLM support
Part number Feature code Description
Security Key Lifecycle Manager - FoD (United States, Canada, Asia Pacific, and Japan)
00D9998 A5U1 SKLM for System x/ThinkSystem w/SEDs - FoD per Install with 1 year S&S
00D9999 AS6C SKLM for System x/ThinkSystem w/SEDs - FoD per Install with 3 year S&S
Security Key Lifecycle Manager - FoD (Latin America, Europe, Middle East, and Africa)
00FP648 A5U1 SKLM for System x/ThinkSystem w/SEDs - FoD per Install with 1 year S&S
00FP649 AS6C SKLM for System x/ThinkSystem w/SEDs - FoD per Install with 3 year S&S

The IBM Security Key Lifecycle Manager software is available from Lenovo using the ordering information listed in the following table.

Table 32. IBM Security Key Lifecycle Manager licenses
Part number Description
7S0A007FWW IBM Security Key Lifecycle Manager Basic Edition Install License + SW Subscription & Support 12 Months
7S0A007HWW IBM Security Key Lifecycle Manager For Raw Decimal Terabyte Storage Resource Value Unit License + SW Subscription & Support 12 Months
7S0A007KWW IBM Security Key Lifecycle Manager For Raw Decimal Petabyte Storage Resource Value Unit License + SW Subscription & Support 12 Months
7S0A007MWW IBM Security Key Lifecycle Manager For Usable Decimal Terabyte Storage Resource Value Unit License + SW Subscription & Support 12 Months
7S0A007PWW IBM Security Key Lifecycle Manager For Usable Decimal Petabyte Storage Resource Value Unit License + SW Subscription & Support 12 Months

Controllers for internal storage

The following table lists the storage controllers and options for internal storage of the SR650 server.

Onboard SATA: The SR650 does not offer onboard SATA

Table 33. RAID controllers and HBAs for internal storage
Part number Feature code Description Maximum quantity Slots
supported
12 Gb SAS/SATA RAID controllers - 8-port adapters
7Y37A01082 AUNG ThinkSystem RAID 530-8i PCIe 12Gb Adapter 2 7,4,2,3,1,5,6
4Y37A78834 BMFT ThinkSystem RAID 540-8i PCIe Gen4 12Gb Adapter 2 4,2,3,1,5,6
4Y37A72482 BJHK ThinkSystem RAID 5350-8i PCIe 12Gb Adapter 3 4,2,3,1,5,6
7Y37A01083 AUNH ThinkSystem RAID 730-8i 1GB Cache PCIe 12Gb Adapter 3 7,4,2,3,1,5,6
4Y37A09722 B4RQ ThinkSystem RAID 730-8i 2GB Flash PCIe 12Gb Adapter 3 7,4,2,3,1,5,6
7Y37A01084 AUNJ ThinkSystem RAID 930-8i 2GB Flash PCIe 12Gb Adapter 3 7,4,2,3,1,5,6
4Y37A72483 BJHL ThinkSystem RAID 9350-8i 2GB Flash PCIe 12Gb Adapter 3 4,2,3,1,5,6
4Y37A09728 B8NY ThinkSystem RAID 940-8i 4GB Flash PCIe Gen4 12Gb Adapter 3 4,2,3,1,5,6
12 Gb SAS/SATA RAID controllers - 16-port adapters
4Y37A09727 B6CE ThinkSystem RAID 530-16i PCIe 12Gb Adapter 2 7,4,2,3,1,5,6
4Y37A78835 BNAX ThinkSystem RAID 540-16i PCIe Gen4 12Gb Adapter 2 4,2,3,1,5,6
7Y37A01085 AUNK ThinkSystem RAID 930-16i 4GB Flash PCIe 12Gb Adapter 2 7,4,2,3,1,5,6
4Y37A72485 BJHN ThinkSystem RAID 9350-16i 4GB Flash PCIe 12Gb Adapter 2 4,2,3,1,5,6
4Y37A09721 B31E ThinkSystem RAID 930-16i 8GB Flash PCIe 12Gb Adapter 2 7,4,2,3,1,5,6
4Y37A78600 BM35 ThinkSystem RAID 940-16i 4GB Flash PCIe Gen4 12Gb Adapter 2 4,2,3,1,5,6
4Y37A09730 B8NZ ThinkSystem RAID 940-16i 8GB Flash PCIe Gen4 12Gb Adapter 2 4,2,3,1,5,6
12 Gb SAS/SATA RAID controllers - 24 and 32-port adapters
7Y37A01086 AUV1 ThinkSystem RAID 930-24i 4GB Flash PCIe 12Gb Adapter 1 1,2,3,5,6
4Y37A09733 B8P8 ThinkSystem RAID 940-32i 8GB Flash PCIe Gen4 12Gb Adapter 1 1,2,3,5,6
12 Gb SAS/SATA non-RAID HBAs
7Y37A01088 AUNL ThinkSystem 430-8i SAS/SATA 12Gb HBA 4 7,4,2,3,1,5,6
4Y37A72480 BJHH ThinkSystem 4350-8i SAS/SATA 12Gb HBA 4 4,2,3,1,5,6
4Y37A78601 BM51 ThinkSystem 440-8i SAS/SATA PCIe Gen4 12Gb HBA 4 4,2,3,1,5,6
7Y37A01089 AUNM ThinkSystem 430-16i SAS/SATA 12Gb HBA 2 7,4,2,3,1,5,6
4Y37A72481 BJHJ ThinkSystem 4350-16i SAS/SATA 12Gb HBA 2 4,2,3,1,5,6
4Y37A78602 BM50 ThinkSystem 440-16i SAS/SATA PCIe Gen4 12Gb HBA 2 4,2,3,1,5,6
NVMe PCIe interfaces
None B9X7 Intel VROC (VMD NVMe RAID) Intel SSD Only (Standard) 1 Not applicable
4L47A39164 B96G Intel VROC (VMD NVMe RAID) Premium
(license upgrade - to enable RAID support for non-Intel NVMe SSDs)
1 Not applicable
4Y37A09737 B8P5 ThinkSystem 1611-8P PCIe Gen4 Switch Adapter 3 1, 5, 6
None* B22D ThinkSystem 810-4P NVMe Switch Adapter 4 2, 4, 7, 6
7Y37A01081 AUV2 ThinkSystem 1610-4P NVMe Switch Adapter 3 1, 5, 6
None^ B4PA ThinkSystem 1610-8P NVMe Switch Adapter 1 1

* The 810-4P NVMe adapter can be factory-installed, or it is included in the 20-drive and 24-drive U.2 NVMe upgrade kits for field upgrades.
^ The 1610-8P NVMe adapter can be factory-installed, or it is included in the 24-drive NVMe upgrade kit for field upgrades.

For a comparison of the functions of the supported storage adapters, see the ThinkSystem RAID Adapter and HBA Reference:
https://lenovopress.com/lp1288-thinksystem-raid-adapter-and-hba-reference#sr650-support=SR650

For more information about the server configurations with 16/20/24x 2.5-inch U.2 NVMe PCIe drive bays, refer to the NVMe-Rich Configurations of the ThinkSystem SR650 article, http://lenovopress.com/LP0904

Configuration notes:

  • Low profile SAS RAID controllers and HBAs for internal storage are supported in the PCIe x8 slots on the system board and full-high PCIe x8 and x16 slots supplied by the riser card 1. Full-height SAS RAID controllers for internal storage (RAID 930-24i) are supported in the full-height PCIe x8 and x16 slots supplied by the riser card 1.
  • If the RAID 930-24i controller is used in the configurations with 24 front drives and 2 rear drives, the RAID 930-24i controller that connects the front drive bays must be installed in the PCIe slot 5, and the RAID 530-8i controller or 430-8i HBA that connects the rear drive bays must be installed in the onboard PCIe slot 7.
  • Either RAID 530-8i or RAID 730-8i 1GB controllers can be used in the server, but not both types.
  • The RAID 730-8i 2GB controller cannot be used in the server configurations with the RAID 930-8i or RAID 730-8i 1GB controllers.
  • The RAID 730-8i 1GB controller does not support the 3.5" Rear HDD Kit.
  • Configurations using onboard NVMe and NVMe switch adapters support RAID using Intel VROC NVMe RAID as described in the Intel VROC onboard RAID section.
  • In the configurations with 2.5-inch AnyBay drive bays, the 1610-4P NVMe Switch Adapter is supported in the full-height PCIe x16 slots supplied by the riser cards 1 and 2.
    • In the configurations with one processor, the 1610-4P NVMe Switch Adapter provides 4x PCIe 3.0 x4 ports for connectivity to U.2 NVMe PCIe SSDs in four AnyBay drive bays, and it is supported in the PCIe x16 slot 1 supplied by the x16/x8 Riser Card 1 (the 1610-4P NVMe Switch Adapter has a PCIe 3.0 x16 host interface).
    • In the configurations with two processors, the onboard NVMe interface and up to two 1610-4P NVMe Switch Adapters provide 4x PCIe 3.0 x4 ports each for connectivity to U.2 NVMe PCIe SSDs in the AnyBay drive bays. Two 1610-4P NVMe Switch Adapters are supported in the PCIe x16 slots 1 and 5 or 1 and 6 only.
  • Configurations with 16x 2.5-inch U.2 NVMe PCIe drive bays use the following interfaces and adapters for balanced connectivity to up to 16x U.2 NVMe PCIe SSDs (up to eight SSDs per processor) without oversubscription:
    • The onboard NVMe interface (Processor 2) that provides four PCIe 3.0 x4 ports for connections to four SSDs without oversubscription.
    • Two 810-4P NVMe Switch adapters installed in the PCIe x8 Slots 4 and 7 (Processor 1) that provide two PCIe 3.0 x4 ports each for connections to four SSDs (two SSDs per 810-4P) without oversubscription.
    • Two 1610-4P NVMe Switch adapters installed in the PCIe x16 Slot 1 (Processor 1) and PCIe x16 Slot 6 (Processor 2) that provide four PCIe 3.0 x4 ports each for connections to eight SSDs (four SSDs per 1610-4P) without oversubscription.
    • If the additional 8-bay SAS/SATA backplane is installed, it is connected to a supported internal storage controller installed in the PCIe x8 slot 3.
  • Configurations with 20x 2.5-inch U.2 NVMe PCIe drive bays use the following interfaces and adapters for connectivity to up to 20x U.2 NVMe PCIe SSDs (up to eight SSDs per Processor 1, and up to 12 SSDs per Processor 2) without oversubscription:
    • The onboard NVMe interface (Processor 2) that provides four PCIe 3.0 x4 ports for connections to four SSDs without oversubscription.
    • Two 810-4P NVMe Switch adapters installed in the PCIe x8 Slots 4 and 7 (Processor 1) that provide two PCIe 3.0 x4 ports each for connections to four SSDs (two SSDs per 810-4P) without oversubscription.
    • Three 1610-4P NVMe Switch adapters installed in the PCIe x16 Slot 1 (Processor 1) and PCIe x16 Slots 5 and 6 (Processor 2) that provide four PCIe 3.0 x4 ports each for connections to twelve SSDs (four SSDs per 1610-4P) without oversubscription.
  • Configurations with 24x 2.5-inch U.2 NVMe PCIe drive bays use the following interfaces and adapters for balanced connectivity to up to 24x U.2 NVMe PCIe SSDs (up to 12 SSDs per processor) with 2:1 oversubscription:
    • One 1610-8P NVMe Switch Adapter installed in the PCIe x16 Slot 1 (Processor 2) that provides eight PCIe 3.0 x4 ports for connections to eight SSDs with 2:1 oversubscription.
    • Four 810-4P NVMe Switch adapters installed in the PCIe x8 Slots 2, 4, and 7 (Processor 1) and PCIe x16 Slot 6 (Processor 2) that provide four PCIe 3.0 x4 ports each for connections to 16 SSDs (four SSDs per 810-4P) with 2:1 oversubscription.
  • In the configurations without GPU installed, the total quantity of the RAID 730, RAID 930, RAID 9350 and RAID 940 controllers with supercaps must not exceed 4 (up to 4 supercapacitors can be mounted in the server).
  • In the configurations with GPU installed, the total quantity of the RAID 730, RAID 930, RAID 9350 and RAID 940 controllers with supercaps must not exceed 3 (up to 3 supercapacitors can be mounted in the server).

  • E810 Ethernet and X350 RAID/HBAs: The use of both an Intel E810 network adapter and an X350 HBA/RAID adapter (9350, 5350 and 4350) is supported, however E810 firmware CVL4.3 or later is required. For details, see Support Tip HT513226.

Intel VROC onboard RAID

Intel VROC (Virtual RAID on CPU) is a feature of the Intel processor that enables Integrated RAID support.

On the SR650, Intel VROC provides RAID functions for the onboard NVMe controller (Intel VROC NVMe RAID).

VROC NVMe RAID offers RAID support for any NVMe drives directly connected to the ports on the server's system board or via adapters such as NVMe retimers or NVMe switch adapters. On the SR650, RAID levels implemented are based on the VROC feature selected as indicated in the following table. RAID 1 is limited to 2 drives per array, and RAID 10 is limited to 4 drives per array. Hot-spare functionality is also supported.

Performance tip: For best performance with VROC NVMe RAID, the drives in an array should all be connected to the same processor. Spanning processors is possible however performance will be unpredictable and should be evaluated based on your workload.

The SR650 supports the VROC NVMe RAID offerings listed in the following table. The VROC Intel SSD Only offering only supports RAID on Intel branded NVMe SSDs; non-Intel branded NVMe SSDs cannot be configured in a RAID array.

Table 34. Intel VROC NVMe RAID ordering information and feature support
Part
number
Feature
code
Description Intel
NVMe SSDs
Non-Intel
NVMe SSDs
RAID 0 RAID 1 RAID 10 RAID 5
CTO only B9X7 Intel VROC (VMD NVMe RAID) Intel SSD Only Yes No Yes Yes Yes Yes
4L47A39164 B96G Intel VROC (VMD NVMe RAID) Premium Yes Yes Yes Yes Yes Yes

Configuration notes:

  • If a feature code is ordered in a CTO build, the VROC functionality is enabled in the factory. For field upgrades, order a part number and it will be fulfilled as a Feature on Demand (FoD) license which can then be activated via the XCC management processor user interface.

Virtualization support: Virtualization support for Intel VROC is as follows:

  • VROC (VMD) NVMe RAID: VROC (VMD) NVMe RAID is supported by ESXi, KVM, Xen, and Hyper-V. ESXi support is limited to RAID 1 only; other RAID levels are not supported. Windows and Linux OSes support VROC RAID NVMe, both for host boot functions and for guest OS function, and RAID-0, 1, 5, and 10 are supported. On ESXi, VROC is supported with both boot and data drives.

 

Internal drive options

The following tables list the drive options for internal storage of the server.

M.2 drives:

M.2 drive support: The use of M.2 drives requires an additional adapter as described in the M.2 drives subsection.

SED support: The tables include a column to indicate which drives support SED encryption. The encryption functionality can be disabled if needed. Note: Not all SED-enabled drives have "SED" in the description.

PCIe 4.0 NVMe drive support: When installed in this server, PCIe 4.0 NVMe drives will operate at PCIe 3.0 speeds.

Table 35. 2.5-inch hot-swap 12 Gb SAS HDDs
Part number Feature
code
Description SED
support
Max
Qty
2.5-inch hot-swap HDDs - 12 Gb SAS 15K
7XB7A00021 AULV ThinkSystem 2.5" 300GB 15K SAS 12Gb Hot Swap 512n HDD No 24
7XB7A00022 AULW ThinkSystem 2.5" 600GB 15K SAS 12Gb Hot Swap 512n HDD No 24
7XB7A00023 AULX ThinkSystem 2.5" 900GB 15K SAS 12Gb Hot Swap 512e HDD No 24
2.5-inch hot-swap HDDs - 12 Gb SAS 10K
7XB7A00024 AULY ThinkSystem 2.5" 300GB 10K SAS 12Gb Hot Swap 512n HDD No 24
7XB7A00025 AULZ ThinkSystem 2.5" 600GB 10K SAS 12Gb Hot Swap 512n HDD No 24
7XB7A00026 AUM0 ThinkSystem 2.5" 900GB 10K SAS 12Gb Hot Swap 512n HDD No 24
7XB7A00027 AUM1 ThinkSystem 2.5" 1.2TB 10K SAS 12Gb Hot Swap 512n HDD No 24
7XB7A00028 AUM2 ThinkSystem 2.5" 1.8TB 10K SAS 12Gb Hot Swap 512e HDD No 24
7XB7A00069 B0YS ThinkSystem 2.5" 2.4TB 10K SAS 12Gb Hot Swap 512e HDD No 24
2.5-inch hot-swap HDDs - 12 Gb NL SAS
7XB7A00034 AUM6 ThinkSystem 2.5" 1TB 7.2K SAS 12Gb Hot Swap 512n HDD No 24
7XB7A00035 AUM7 ThinkSystem 2.5" 2TB 7.2K SAS 12Gb Hot Swap 512n HDD No 24
2.5-inch hot-swap SED HDDs - 12 Gb SAS 10K
7XB7A00030 AUM4 ThinkSystem 2.5" 300GB 10K SAS 12Gb Hot Swap 512n HDD SED Support 24
7XB7A00031 AUM5 ThinkSystem 2.5" 600GB 10K SAS 12Gb Hot Swap 512n HDD SED Support 24
7XB7A00033 B0YX ThinkSystem 2.5" 1.2TB 10K SAS 12Gb Hot Swap 512n HDD SED Support 24
7XB7A00070 B0YV ThinkSystem 2.5" 2.4TB 10K SAS 12Gb Hot Swap 512e HDD FIPS Support 24
2.5-inch hot-swap SED HDDs - 12 Gb NL SAS
7XB7A00064 B0YM ThinkSystem 2.5" 2TB 7.2K SAS 12Gb Hot Swap 512e HDD FIPS Support 24
Table 36. 2.5-inch hot-swap 6 Gb SATA HDDs
Part number Feature
code
Description SED
support
Max
Qty
2.5-inch hot-swap HDDs - 6 Gb NL SATA
7XB7A00036 AUUE ThinkSystem 2.5" 1TB 7.2K SATA 6Gb Hot Swap 512n HDD No 24
7XB7A00037 AUUJ ThinkSystem 2.5" 2TB 7.2K SATA 6Gb Hot Swap 512e HDD No 24
Table 37. 2.5-inch hot-swap 24 Gb SAS SSDs
Part number Feature
code
Description SED
support
Max
Qty
2.5-inch hot-swap SSDs - 24 Gb SAS - Mixed Use/Mainstream (3-5 DWPD)
4XB7A80340 BNW8 ThinkSystem 2.5" PM1655 800GB Mixed Use SAS 24Gb HS SSD Support 24
4XB7A80341 BNW9 ThinkSystem 2.5" PM1655 1.6TB Mixed Use SAS 24Gb HS SSD Support 24
4XB7A80342 BNW6 ThinkSystem 2.5" PM1655 3.2TB Mixed Use SAS 24Gb HS SSD Support 24
4XB7A80343 BP3K ThinkSystem 2.5" PM1655 6.4TB Mixed Use SAS 24Gb HS SSD Support 24
2.5-inch hot-swap SSDs - 24 Gb SAS - Read Intensive/Entry/Capacity (<3 DWPD)
4XB7A80318 BNWC ThinkSystem 2.5" PM1653 960GB Read Intensive SAS 24Gb HS SSD Support 24
4XB7A80319 BNWE ThinkSystem 2.5" PM1653 1.92TB Read Intensive SAS 24Gb HS SSD Support 24
4XB7A80320 BNWF ThinkSystem 2.5" PM1653 3.84TB Read Intensive SAS 24Gb HS SSD Support 24
4XB7A80321 BP3E ThinkSystem 2.5" PM1653 7.68TB Read Intensive SAS 24Gb HS SSD Support 24
4XB7A80322 BP3J ThinkSystem 2.5" PM1653 15.36TB Read Intensive SAS 24Gb HS SSD Support 24
4XB7A80323 BP3D ThinkSystem 2.5" PM1653 30.72TB Read Intensive SAS 24Gb HS SSD Support 24
Table 38. 2.5-inch hot-swap 12 Gb SAS SSDs
Part number Feature
code
Description SED
support
Max
Qty
2.5-inch hot-swap SSDs - 12 Gb SAS - Write Intensive/Performance (10+ DWPD)
4XB7A83214 BR10 ThinkSystem 2.5" Nytro 3750 400GB Write Intensive SAS 12Gb HS SSD Support 24
4XB7A83215 BR0Z ThinkSystem 2.5" Nytro 3750 800GB Write Intensive SAS 12Gb HS SSD Support 24
4XB7A83216 BR0Y ThinkSystem 2.5" Nytro 3750 1.6TB Write Intensive SAS 12Gb HS SSD Support 24
4XB7A83217 BR0X ThinkSystem 2.5" Nytro 3750 3.2TB Write Intensive SAS 12Gb HS SSD Support 24
4XB7A70006 BG07 ThinkSystem 2.5" Nytro 3732 400GB Performance SAS 12Gb Hot Swap SSD No 24
4XB7A70005 BG06 ThinkSystem 2.5" Nytro 3732 800GB Performance SAS 12Gb Hot Swap SSD No 24
4XB7A70007 BFZZ ThinkSystem 2.5" Nytro 3732 800GB Performance SAS 12Gb Hot Swap SSD SED Support 24
4XB7A70004 BG05 ThinkSystem 2.5" Nytro 3732 1.6TB Performance SAS 12Gb Hot Swap SSD No 24
4XB7A70003 BG04 ThinkSystem 2.5" Nytro 3732 3.2TB Performance SAS 12Gb Hot Swap SSD No 24
4XB7A10219 B4Y4 ThinkSystem 2.5" SS530 400GB Performance SAS 12Gb Hot Swap SSD No 24
4XB7A10230 B4Y5 ThinkSystem 2.5" SS530 800GB Performance SAS 12Gb Hot Swap SSD No 24
4XB7A10231 B4Y6 ThinkSystem 2.5" SS530 1.6TB Performance SAS 12Gb Hot Swap SSD No 24
4XB7A10232 B4Y7 ThinkSystem 2.5" SS530 3.2TB Performance SAS 12Gb Hot Swap SSD No 24
7N47A00124 AUMG ThinkSystem 2.5" HUSMM32 400GB Performance SAS 12Gb Hot Swap SSD No 24
7N47A00125 AUMH ThinkSystem 2.5" HUSMM32 800GB Performance SAS 12Gb Hot Swap SSD No 24
7N47A00126 AVRB ThinkSystem 2.5" HUSMM32 1.6TB Performance SAS 12Gb Hot Swap SSD No 24
7SD7A05754 B11P ThinkSystem 2.5" HUSMM32 400GB Performance SAS 12Gb Hot Swap SSD FIPS Support 24
7SD7A05753 B11Q ThinkSystem 2.5" HUSMM32 800GB Performance SAS 12Gb Hot Swap SSD FIPS Support 24
7SD7A05752 B11R ThinkSystem 2.5" HUSMM32 1.6TB Performance SAS 12Gb Hot Swap SSD FIPS Support 24
2.5-inch hot-swap SSDs - 12 Gb SAS - Mixed Use/Mainstream (3-5 DWPD)
4XB7A17062 B8HU ThinkSystem 2.5" PM1645a 800GB Mainstream SAS 12Gb Hot Swap SSD No 24
4XB7A17063 B8J4 ThinkSystem 2.5" PM1645a 1.6TB Mainstream SAS 12Gb Hot Swap SSD No 24
4XB7A17064 B8JD ThinkSystem 2.5" PM1645a 3.2TB Mainstream SAS 12Gb Hot Swap SSD No 24
4XB7A17065 B8JA ThinkSystem 2.5" PM1645a 6.4TB Mainstream SAS 12Gb Hot Swap SSD No 24
4XB7A13653 B4A0 ThinkSystem 2.5" PM1645 800GB Mainstream SAS 12Gb Hot Swap SSD No 24
4XB7A13654 B4A1 ThinkSystem 2.5" PM1645 1.6TB Mainstream SAS 12Gb Hot Swap SSD No 24
4XB7A13655 B4A2 ThinkSystem 2.5" PM1645 3.2TB Mainstream SAS 12Gb Hot Swap SSD No 24
7N47A00117 AUMC ThinkSystem 2.5" PM1635a 400GB Mainstream SAS 12Gb Hot Swap SSD No 24
7N47A00118 AUMD ThinkSystem 2.5" PM1635a 800GB Mainstream SAS 12Gb Hot Swap SSD No 24
7N47A00119 AVRG ThinkSystem 2.5" PM1635a 1.6TB Mainstream SAS 12Gb Hot Swap SSD No 24
7N47A00120 AVRJ ThinkSystem 2.5" PM1635a 3.2TB Mainstream SAS 12Gb Hot Swap SSD No 24
2.5-inch hot-swap SSDs - 12 Gb SAS - Read Intensive/Entry/Capacity (<3 DWPD)
4XB7A38175 B91A ThinkSystem 2.5" PM1643a 960GB Entry SAS 12Gb Hot Swap SSD No 24
4XB7A38176 B91B ThinkSystem 2.5" PM1643a 1.92TB Entry SAS 12Gb Hot Swap SSD No 24
4XB7A17054 B91C ThinkSystem 2.5" PM1643a 3.84TB Entry SAS 12Gb Hot Swap SSD No 24
4XB7A17055 B91D ThinkSystem 2.5" PM1643a 7.68TB Entry SAS 12Gb Hot Swap SSD No 24
4XB7A17056 BC4R ThinkSystem 2.5" PM1643a 15.36TB Entry SAS 12Gb Hot Swap SSD No 24
4XB7A17168 B6TL ThinkSystem 2.5" PM1643 960GB Entry SAS 12Gb Hot Swap SSD No 24
4XB7A13645 B4A7 ThinkSystem 2.5" PM1643 3.84TB Capacity SAS 12Gb Hot Swap SSD No 24
4XB7A13646 B4A6 ThinkSystem 2.5" PM1643 7.68TB Capacity SAS 12Gb Hot Swap SSD No 24
7N47A00121 AUMK ThinkSystem 2.5" PM1633a 3.84TB Capacity SAS 12Gb Hot Swap SSD No 24
7N47A00122 AUML ThinkSystem 2.5" PM1633a 7.68TB Capacity SAS 12Gb Hot Swap SSD No 24
7N47A00123 B116 ThinkSystem 2.5" PM1633a 15.36TB Capacity SAS 12Gb Hot Swap SSD No 24
Table 39. 2.5-inch hot-swap 6 Gb SATA SSDs
Part number Feature
code
Description SED
support
Max
Qty
2.5-inch hot-swap SSDs - 6 Gb SATA - Mixed Use/Mainstream (3-5 DWPD)
4XB7A82289 BQ21 ThinkSystem 2.5" 5400 MAX 480GB Mixed Use SATA 6Gb HS SSD Support 24
4XB7A82290 BQ24 ThinkSystem 2.5" 5400 MAX 960GB Mixed Use SATA 6Gb HS SSD Support 24
4XB7A82291 BQ22 ThinkSystem 2.5" 5400 MAX 1.92TB Mixed Use SATA 6Gb HS SSD Support 24
4XB7A82292 BQ23 ThinkSystem 2.5" 5400 MAX 3.84TB Mixed Use SATA 6Gb HS SSD Support 24
4XB7A17125 BA7Q ThinkSystem 2.5" S4620 480GB Mixed Use SATA 6Gb HS SSD No 24
4XB7A17126 BA4T ThinkSystem 2.5" S4620 960GB Mixed Use SATA 6Gb HS SSD No 24
4XB7A17127 BA4U ThinkSystem 2.5" S4620 1.92TB Mixed Use SATA 6Gb HS SSD No 24
4XB7A17128 BK7L ThinkSystem 2.5" S4620 3.84TB Mixed Use SATA 6Gb HS SSD No 24
4XB7A17087 B8J1 ThinkSystem 2.5" 5300 240GB Mainstream SATA 6Gb Hot Swap SSD No 24
4XB7A17088 B8HY ThinkSystem 2.5" 5300 480GB Mainstream SATA 6Gb Hot Swap SSD No 24
4XB7A17089 B8J6 ThinkSystem 2.5" 5300 960GB Mainstream SATA 6Gb Hot Swap SSD No 24
4XB7A13972 BNEW ThinkSystem 2.5" 5300 960GB  Mainstream SATA 6Gb Hot Swap SSD SED Support 24
4XB7A17090 B8JE ThinkSystem 2.5" 5300 1.92TB Mainstream SATA 6Gb Hot Swap SSD No 24
4XB7A38193 B93K ThinkSystem 2.5" 5300 1.92TB Mainstream SATA 6Gb Hot Swap SSD SED Support 24
4XB7A17091 B8J7 ThinkSystem 2.5" 5300 3.84TB Mainstream SATA 6Gb Hot Swap SSD No 24
4XB7A64222 BEMB ThinkSystem 2.5" 5300 3.84TB Mainstream SATA 6Gb Hot Swap SSD SED Support 24
4XB7A13633 B49L ThinkSystem 2.5" S4610 240GB Mixed Use SATA 6Gb HS SSD No 24
4XB7A13634 B49M ThinkSystem 2.5" S4610 480GB Mixed Use SATA 6Gb HS SSD No 24
4XB7A13635 B49N ThinkSystem 2.5" S4610 960GB Mixed Use SATA 6Gb HS SSD No 24
4XB7A13636 B49P ThinkSystem 2.5" S4610 1.92TB Mixed Use SATA 6Gb HS SSD No 24
4XB7A13637 B49Q ThinkSystem 2.5" S4610 3.84TB Mixed Use SATA 6Gb HS SSD No 24
4XB7A10237 B488 ThinkSystem 2.5" 5200 240GB Mainstream SATA 6Gb Hot Swap SSD No 24
4XB7A10238 B489 ThinkSystem 2.5" 5200 480GB Mainstream SATA 6Gb Hot Swap SSD No 24
4XB7A10239 B48A ThinkSystem 2.5" 5200 960GB Mainstream SATA 6Gb Hot Swap SSD No 24
4XB7A14062 B6K1 ThinkSystem 2.5" 5200 960GB Mainstream SATA 6Gb Hot Swap SSD SED Support 24
4XB7A10240 B48B ThinkSystem 2.5" 5200 1.92TB Mainstream SATA 6Gb Hot Swap SSD No 24
4XB7A14063 B6K0 ThinkSystem 2.5" 5200 1.92TB Mainstream SATA 6Gb Hot Swap SSD SED Support 24
4XB7A13981 B93J ThinkSystem 2.5" 5200 (Max) 1.92TB Mainstream SATA 6Gb Hot Swap SSD SED Support 24
4XB7A10241 B48C ThinkSystem 2.5" 5200 3.84TB Mainstream SATA 6Gb Hot Swap SSD No 24
4XB7A13982 B81X ThinkSystem 2.5" 5200 3.84TB Mainstream SATA 6Gb Hot Swap SSD SED Support 24
7SD7A05723 B0ZP ThinkSystem 2.5" Intel S4600 240GB Mainstream SATA 6Gb Hot Swap SSD No 24
7SD7A05722 B0ZQ ThinkSystem 2.5" Intel S4600 480GB Mainstream SATA 6Gb Hot Swap SSD No 24
7SD7A05721 B0ZR ThinkSystem 2.5" Intel S4600 960GB Mainstream SATA 6Gb Hot Swap SSD No 24
7SD7A05720 B0ZS ThinkSystem 2.5" Intel S4600 1.92TB Mainstream SATA 6Gb Hot Swap SSD No 24
7SD7A05765 B10W ThinkSystem 2.5" 5100 240GB Mainstream SATA 6Gb Hot Swap SSD No 24
7SD7A05764 B10X ThinkSystem 2.5" 5100 480GB Mainstream SATA 6Gb Hot Swap SSD No 24
7SD7A05763 B10Y ThinkSystem 2.5" 5100 960GB Mainstream SATA 6Gb Hot Swap SSD No 24
7SD7A05762 B10Z ThinkSystem 2.5" 5100 1.92TB Mainstream SATA 6Gb Hot Swap SSD No 24
7SD7A05761 B110 ThinkSystem 2.5" 5100 3.84TB Mainstream SATA 6Gb Hot Swap SSD No 24
2.5-inch hot-swap SSDs - 6 Gb SATA - Read Intensive/Entry (<3 DWPD)
4XB7A82258 BQ1Q ThinkSystem 2.5" 5400 PRO 240GB Read Intensive SATA 6Gb HS SSD Support 24
4XB7A82259 BQ1P ThinkSystem 2.5" 5400 PRO 480GB Read Intensive SATA 6Gb HS SSD Support 24
4XB7A82260 BQ1R ThinkSystem 2.5" 5400 PRO 960GB Read Intensive SATA 6Gb HS SSD Support 24
4XB7A82261 BQ1X ThinkSystem 2.5" 5400 PRO 1.92TB Read Intensive SATA 6Gb HS SSD Support 24
4XB7A82262 BQ1S ThinkSystem 2.5" 5400 PRO 3.84TB Read Intensive SATA 6Gb HS SSD Support 24
4XB7A82263 BQ1T ThinkSystem 2.5" 5400 PRO 7.68TB Read Intensive SATA 6Gb HS SSD Support 24
4XB7A72438 BM8B ThinkSystem 2.5" PM893 480GB Read Intensive SATA 6Gb HS SSD No 24
4XB7A72439 BM8A ThinkSystem 2.5" PM893 960GB Read Intensive SATA 6Gb HS SSD No 24
4XB7A72440 BM89 ThinkSystem 2.5" PM893 1.92TB Read Intensive SATA 6Gb HS SSD No 24
4XB7A72441 BM88 ThinkSystem 2.5" PM893 3.84TB Read Intensive SATA 6Gb HS SSD No 24
4XB7A72442 BM87 ThinkSystem 2.5" PM893 7.68TB Read Intensive SATA 6Gb HS SSD No 24
4XB7A17072 B99D ThinkSystem 2.5" S4520 240GB Read Intensive SATA 6Gb HS SSD No 24
4XB7A17101 BA7G ThinkSystem 2.5" S4520 480GB Read Intensive SATA 6Gb HS SSD No 24
4XB7A17102 BA7H ThinkSystem 2.5" S4520 960GB Read Intensive SATA 6Gb HS SSD No 24
4XB7A17103 BA7J ThinkSystem 2.5" S4520 1.92TB Read Intensive SATA 6Gb HS SSD No 24
4XB7A17104 BK77 ThinkSystem 2.5" S4520 3.84TB Read Intensive SATA 6Gb HS SSD No 24
4XB7A17105 BK78 ThinkSystem 2.5" S4520 7.68TB Read Intensive SATA 6Gb HS SSD No 24
4XB7A38271 BCTC ThinkSystem 2.5" Multi Vendor 240GB Entry SATA 6Gb Hot Swap SSD No 24
4XB7A38272 BCTD ThinkSystem 2.5" Multi Vendor 480GB Entry SATA 6Gb Hot Swap SSD No 24
4XB7A38273 BCTE ThinkSystem 2.5" Multi Vendor 960GB Entry SATA 6Gb Hot Swap SSD No 24
4XB7A38274 BCTF ThinkSystem 2.5" Multi Vendor 1.92TB Entry SATA 6Gb Hot Swap SSD No 24
4XB7A38275 BCTG ThinkSystem 2.5" Multi Vendor 3.84TB Entry SATA 6Gb Hot Swap SSD No 24
4XB7A17075 B8HV ThinkSystem 2.5" 5300 240GB Entry SATA 6Gb Hot Swap SSD No 24
4XB7A17076 B8JM ThinkSystem 2.5" 5300 480GB Entry SATA 6Gb Hot Swap SSD No 24
4XB7A17077 B8HP ThinkSystem 2.5" 5300 960GB Entry SATA 6Gb Hot Swap SSD No 24
4XB7A38141 BE29 ThinkSystem 2.5" 5300 960GB Entry SATA 6Gb Hot Swap SSD SED Support 24
4XB7A17078 B8J5 ThinkSystem 2.5" 5300 1.92TB Entry SATA 6Gb Hot Swap SSD No 24
4XB7A17079 B8JP ThinkSystem 2.5" 5300 3.84TB Entry SATA 6Gb Hot Swap SSD No 24
4XB7A38191 B93L ThinkSystem 2.5" 5300 3.84TB Entry SATA 6Gb Hot Swap SSD SED Support 24
4XB7A17080 B8J2 ThinkSystem 2.5" 5300 7.68TB Entry SATA 6Gb Hot Swap SSD No 24
4XB7A38192 B93M ThinkSystem 2.5" 5300 7.68TB Entry SATA 6Gb Hot Swap SSD SED Support 24
4XB7A38185 B9AC ThinkSystem 2.5" 5210 960GB Entry SATA 6Gb Hot Swap QLC SSD No 24
4XB7A38144 B7EW ThinkSystem 2.5" 5210 1.92TB Entry SATA 6Gb Hot Swap QLC SSD No 24
4XB7A38145 B7EX ThinkSystem 2.5" 5210 3.84TB Entry SATA 6Gb Hot Swap QLC SSD No 24
4XB7A38146 B7EY ThinkSystem 2.5" 5210 7.68TB Entry SATA 6Gb Hot Swap QLC SSD No 24
4XB7A10247 B498 ThinkSystem 2.5" S4510 240GB Read Intensive SATA 6Gb HS SSD No 24
4XB7A10248 B499 ThinkSystem 2.5" S4510 480GB Read Intensive SATA 6Gb HS SSD No 24
4XB7A10249 B49A ThinkSystem 2.5" S4510 960GB Read Intensive SATA 6Gb HS SSD No 24
4XB7A13622 B49B ThinkSystem 2.5" S4510 1.92TB Read Intensive SATA 6Gb HS SSD No 24
4XB7A13623 B49C ThinkSystem 2.5" S4510 3.84TB Read Intensive SATA 6Gb HS SSD No 24
4XB7A10195 B34H ThinkSystem 2.5" PM883 240GB Entry SATA 6Gb Hot Swap SSD No 24
4XB7A10196 B34J ThinkSystem 2.5" PM883 480GB Entry SATA 6Gb Hot Swap SSD No 24
4XB7A10197 B34K ThinkSystem 2.5" PM883 960GB Entry SATA 6Gb Hot Swap SSD No 24
4XB7A10198 B34L ThinkSystem 2.5" PM883 1.92TB Entry SATA 6Gb Hot Swap SSD No 24
4XB7A10199 B34M ThinkSystem 2.5" PM883 3.84TB Entry SATA 6Gb Hot Swap SSD No 24
4XB7A10200 B4D2 ThinkSystem 2.5" PM883 7.68TB Entry SATA 6Gb Hot Swap SSD No 24
7SD7A05742 B0YY ThinkSystem 2.5" Intel S4500 240GB Entry SATA 6Gb Hot Swap SSD No 24
7SD7A05741 B0YZ ThinkSystem 2.5" Intel S4500 480GB Entry SATA 6Gb Hot Swap SSD No 24
7SD7A05740 B0Z0 ThinkSystem 2.5" Intel S4500 960GB Entry SATA 6Gb Hot Swap SSD No 24
7SD7A05739 B0Z1 ThinkSystem 2.5" Intel S4500 1.92TB Entry SATA 6Gb Hot Swap SSD No 24
7SD7A05738 B0Z2 ThinkSystem 2.5" Intel S4500 3.84TB Entry SATA 6Gb Hot Swap SSD No 24
7N47A00111 AUUQ ThinkSystem 2.5" PM863a 240GB Entry SATA 6Gb Hot Swap SSD No 24
7N47A00112 AUM9 ThinkSystem 2.5" PM863a 480GB Entry SATA 6Gb Hot Swap SSD No 24
7N47A00113 AVCZ ThinkSystem 2.5" PM863a 960GB Entry SATA 6Gb Hot Swap SSD No 24
7N47A00114 AVRC ThinkSystem 2.5" PM863a 1.92TB Entry SATA 6Gb Hot Swap SSD No 24
4XB7A10153 B2X2 ThinkSystem 2.5" 5200 480GB Entry SATA 6Gb Hot Swap SSD No 24
4XB7A13966 B4G8 ThinkSystem 2.5" 5200 480GB Entry SATA 6Gb Hot Swap SSD SED Support 24
4XB7A10154 B2X3 ThinkSystem 2.5" 5200 960GB Entry SATA 6Gb Hot Swap SSD No 24
4XB7A10155 B2X4 ThinkSystem 2.5" 5200 1.92TB Entry SATA 6Gb Hot Swap SSD No 24
4XB7A10156 B2X5 ThinkSystem 2.5" 5200 3.84TB Entry SATA 6Gb Hot Swap SSD No 24
4XB7A10157 B2X6 ThinkSystem 2.5" 5200 7.68TB Entry SATA 6Gb Hot Swap SSD No 24
4XB7A08502 B10N ThinkSystem 2.5" 5100 480GB Entry SATA 6Gb Hot Swap SSD No 24
4XB7A08503 B10P ThinkSystem 2.5" 5100 960GB Entry SATA 6Gb Hot Swap SSD No 24
4XB7A08504 B10Q ThinkSystem 2.5" 5100 1.92TB Entry SATA 6Gb Hot Swap SSD No 24
4XB7A08505 B10R ThinkSystem 2.5" 5100 3.84TB Entry SATA 6Gb Hot Swap SSD No 24
7N47A00099 AUM8 ThinkSystem 2.5" Intel S3520 240GB Entry SATA 6Gb Hot Swap SSD No 24
7N47A00100 AUUZ ThinkSystem 2.5" Intel S3520 480GB Entry SATA 6Gb Hot Swap SSD No 24
Table 40. 2.5-inch hot-swap PCIe 4.0 NVMe SSDs
Part number Feature
code
Description SED
support
Max
Qty
2.5-inch SSDs - U.2 PCIe 4.0 NVMe - Mixed Use/Mainstream (3-5 DWPD)
4XB7A17129 BNEG ThinkSystem 2.5" U.2 P5620 1.6TB Mixed Use NVMe PCIe 4.0 x4 HS SSD Support 24
4XB7A17130 BNEH ThinkSystem 2.5" U.2 P5620 3.2TB Mixed Use NVMe PCIe 4.0 x4 HS SSD Support 24
4XB7A17133 BNEZ ThinkSystem 2.5" U.2 P5620 6.4TB Mixed Use NVMe PCIe 4.0 x4 HS SSD Support 24
4XB7A17152 BCFV ThinkSystem 2.5" U.2 P5600 1.6TB Mixed Use NVMe PCIe 4.0 x4 HS SSD No 24
4XB7A17153 BCFR ThinkSystem 2.5" U.2 P5600 3.2TB Mixed Use NVMe PCIe 4.0 x4 HS SSD No 24
4XB7A17154 BCFS ThinkSystem 2.5" U.2 P5600 6.4TB Mixed Use NVMe PCIe 4.0 x4 HS SSD No 24
2.5-inch SSDs - U.3 PCIe 4.0 NVMe - Mixed Use/Mainstream (3-5 DWPD)
4XB7A79639 BNF1 ThinkSystem 2.5" U.3 7450 MAX 800GB Mixed Use NVMe PCIe 4.0 x4 HS SSD Support 24
4XB7A13967 BNEJ ThinkSystem 2.5" U.3 7450 MAX 1.6TB Mixed Use NVMe PCIe 4.0 x4 HS SSD Support 24
4XB7A13970 BNEY ThinkSystem 2.5" U.3 7450 MAX 3.2TB Mixed Use NVMe PCIe 4.0 x4 HS SSD Support 24
4XB7A13971 BNEL ThinkSystem 2.5" U.3 7450 MAX 6.4TB Mixed Use NVMe PCIe 4.0 x4 HS SSD Support 24
4XB7A64175 BE03 ThinkSystem U.3 Kioxia CM6-V 800GB Mainstream NVMe PCIe 4.0 x4 Hot Swap SSD No 24
4XB7A17112 B96Z ThinkSystem U.3 Kioxia CM6-V 1.6TB Mainstream NVMe PCIe4.0 x4 Hot Swap SSD No 24
4XB7A17113 B96T ThinkSystem U.3 Kioxia CM6-V 3.2TB Mainstream NVMe PCIe4.0 x4 Hot Swap SSD No 24
4XB7A17114 B96P ThinkSystem U.3 Kioxia CM6-V 6.4TB Mainstream NVMe PCIe4.0 x4 Hot Swap SSD No 24
2.5-inch SSDs - U.2 PCIe 4.0 NVMe - Read Intensive/Entry (<3 DWPD)
4XB7A13941 BMGD ThinkSystem 2.5" U.2 P5520 1.92TB Read Intensive NVMe PCIe 4.0 x4 HS SSD Support 24
4XB7A13942 BMGE ThinkSystem 2.5" U.2 P5520 3.84TB Read Intensive NVMe PCIe 4.0 x4 HS SSD Support 24
4XB7A13943 BNEF ThinkSystem 2.5" U.2 P5520 7.68TB Read Intensive NVMe PCIe 4.0 x4 HS SSD Support 24
4XB7A13631 BNEQ ThinkSystem 2.5" U.2 P5520 15.36TB Read Intensive NVMe PCIe 4.0 x4 HS SSD Support 24
4XB7A17145 BCFT ThinkSystem 2.5" U.2 P5500 1.92TB Read Intensive NVMe PCIe 4.0 x4 HS SSD No 24
4XB7A17146 BCFW ThinkSystem 2.5" U.2 P5500 3.84TB Read Intensive NVMe PCIe 4.0 x4 HS SSD No 24
4XB7A17147 BCFU ThinkSystem 2.5" U.2 P5500 7.68TB Read Intensive NVMe PCIe 4.0 x4 HS SSD No 24
4XB7A38197 BC4Z ThinkSystem U.2 PM1733 3.84TB Entry NVMe PCIe 4.0 x4 Hot Swap SSD No 24
4XB7A38257 BE2A ThinkSystem U.2 PM1733 3.84TB Entry NVMe PCIe 4.0 x4 Hot Swap SSD SED Support 24
4XB7A38283 BE2E ThinkSystem U.2 PM1733 7.68TB Entry NVMe PCIe 4.0 x4 Hot Swap SSD No 24
4XB7A38258 BE2B ThinkSystem U.2 PM1733 7.68TB Entry NVMe PCIe 4.0 x4 Hot Swap SSD SED Support 24
4XB7A38284 BE2F ThinkSystem U.2 PM1733 15.36TB Entry NVMe PCIe 4.0 x4 Hot Swap SSD No 24
2.5-inch SSDs - U.3 PCIe 4.0 NVMe - Read Intensive/Entry (<3 DWPD)
4XB7A81951 BPKX ThinkSystem 2.5" U.3 PM1733a 1.92TB Read Intensive NVMe PCIe 4.0 x4 HS SSD Support 24
4XB7A81952 BPKY ThinkSystem 2.5" U.3 PM1733a 3.84TB Read Intensive NVMe PCIe 4.0 x4 HS SSD Support 24
4XB7A81953 BPKZ ThinkSystem 2.5" U.3 PM1733a 7.68TB Read Intensive NVMe PCIe 4.0 x4 HS SSD Support 24
4XB7A81954 BPL0 ThinkSystem 2.5" U.3 PM1733a 15.36TB Read Intensive NVMe PCIe 4.0 x4 HS SSD Support 24
4XB7A79646 BNF3 ThinkSystem 2.5" U.3 7450 PRO 960GB Read Intensive NVMe PCIe 4.0 x4 HS SSD Support 24
4XB7A79647 BNF2 ThinkSystem 2.5" U.3 7450 PRO 1.92TB Read Intensive NVMe PCIe 4.0 x4 HS SSD Support 24
4XB7A79648 BNF5 ThinkSystem 2.5" U.3 7450 PRO 3.84TB Read Intensive NVMe PCIe 4.0 x4 HS SSD Support 24
4XB7A79649 BNF4 ThinkSystem 2.5" U.3 7450 PRO 7.68TB Read Intensive NVMe PCIe 4.0 x4 HS SSD Support 24
4XB7A83097 BQAV ThinkSystem 2.5" U.3 7450 PRO 15.36TB Read Intensive NVMe PCIe 4.0 x4 HS SSD Support 24
4XB7A64141 BE2G ThinkSystem U.3 Kioxia CM6-R 3.84TB Entry NVMe PCIe 4.0 x4 Hot Swap SSD No 24
4XB7A38269 BE2C ThinkSystem U.3 Kioxia CM6-R 3.84TB Entry NVMe PCIe 4.0 x4 Hot Swap SSD SED Support 24
4XB7A64142 BE2H ThinkSystem U.3 Kioxia CM6-R 7.68TB Entry NVMe PCIe 4.0 x4 Hot Swap SSD No 24
4XB7A38270 BE2D ThinkSystem U.3 Kioxia CM6-R 7.68TB Entry NVMe PCIe 4.0 x4 Hot Swap SSD SED Support 24

Note: NVMe PCIe SSDs support surprise hot removal and hot insertion, provided the operating system supports PCIe SSD hot-swap.

Table 41. 2.5-inch hot-swap PCIe 3.0 NVMe SSDs
Part number Feature
code
Description SED
support
Max
Qty
2.5-inch SSDs - U.2 PCIe 3.0 NVMe - Write Intensive/Performance (10+ DWPD)
7N47A00081 AUMJ ThinkSystem 2.5" U.2 P4800X 375GB Write Intensive NVMe PCIe 3.0 x4 HS SSD No 24
7N47A00083 B2ZJ ThinkSystem 2.5" U.2 P4800X 750GB Write Intensive NVMe PCIe 3.0 x4 HS SSD No 24
7XB7A05923 AWG6 ThinkSystem U.2 PX04PMB 800GB Performance NVMe PCIe 3.0 x4 Hot Swap SSD No 12*
7XB7A05922 AWG7 ThinkSystem U.2 PX04PMB 1.6TB Performance NVMe PCIe 3.0 x4 Hot Swap SSD No 12*
2.5-inch SSDs - U.2 PCIe 3.0 NVMe - Mixed Use/Mainstream (3-5 DWPD)
4XB7A13936 B589 ThinkSystem U.2 Intel P4610 1.6TB Mainstream NVMe PCIe3.0 x4 Hot Swap SSD No 24
4XB7A13937 B58A ThinkSystem U.2 Intel P4610 3.2TB Mainstream NVMe PCIe3.0 x4 Hot Swap SSD No 24
4XB7A13938 B58B ThinkSystem U.2 Intel P4610 6.4TB Mainstream NVMe PCIe3.0 x4 Hot Swap SSD No 24
4XB7A08516 B21W ThinkSystem U.2 Toshiba CM5-V 800GB Mainstream NVMe PCIe 3.0 x4 Hot Swap SSD No 24
4XB7A08517 B21X ThinkSystem U.2 Toshiba CM5-V 1.6TB Mainstream NVMe PCIe 3.0 x4 Hot Swap SSD No 24
4XB7A08518 B21Y ThinkSystem U.2 Toshiba CM5-V 3.2TB Mainstream NVMe PCIe 3.0 x4 Hot Swap SSD No 24
4XB7A08519 B2XJ ThinkSystem U.2 Toshiba CM5-V 6.4TB Mainstream NVMe PCIe 3.0 x4 Hot Swap SSD No 24
7N47A00095 AUUY ThinkSystem U.2 PX04PMB 960GB Mainstream NVMe PCIe 3.0 x4 Hot Swap SSD No 12*
7N47A00096 AUMF ThinkSystem U.2 PX04PMB 1.92TB Mainstream NVMe PCIe 3.0 x4 Hot Swap SSD No 12*
7SD7A05772 B11J ThinkSystem U.2 Intel P4600 1.6TB Mainstream NVMe PCIe3.0 x4 Hot Swap SSD No 24
7SD7A05771 B11K ThinkSystem U.2 Intel P4600 3.2TB Mainstream NVMe PCIe3.0 x4 Hot Swap SSD No 24
7SD7A05770 B11L ThinkSystem U.2 Intel P4600 6.4TB Mainstream NVMe PCIe3.0 x4 Hot Swap SSD No 12*
2.5-inch SSDs - U.2 PCIe 3.0 NVMe - Read Intensive/Entry (<3 DWPD)
4XB7A14060 B6K4 ThinkSystem U.2 CM5-R 3.84TB Entry NVMe PCIe 3.0 x4 Hot Swap SSD SED Support 24
4XB7A10202 B58F ThinkSystem U.2 Intel P4510 1.0TB Entry NVMe PCIe3.0 x4 Hot Swap SSD No 24
4XB7A10204 B58G ThinkSystem 2.5" U.2 P4510 2.0TB Read Intensive NVMe PCIe 3.0 x4 HS SSD No 24
4XB7A10205 B58H ThinkSystem U.2 Intel P4510 4.0TB Entry NVMe PCIe3.0 x4 Hot Swap SSD No 24
4XB7A08513 B58J ThinkSystem U.2 Intel P4510 8.0TB Entry NVMe PCIe3.0 x4 Hot Swap SSD No 24
4XB7A10175 B34N ThinkSystem U.2 PM983 1.92TB Entry NVMe PCIe 3.0 x4 Hot Swap SSD No 24
4XB7A10176 B34P ThinkSystem U.2 PM983 3.84TB Entry NVMe PCIe 3.0 x4 Hot Swap SSD No 24
4XB7A10177 B4D3 ThinkSystem U.2 PM983 7.68TB Entry NVMe PCIe3.0 x4 Hot Swap SSD No 24
7N47A00984 AUV0 ThinkSystem U.2 PM963 1.92TB Entry NVMe PCIe 3.0 x4 Hot Swap SSD No 12*
7N47A00985 AUUU ThinkSystem U.2 PM963 3.84TB Entry NVMe PCIe 3.0 x4 Hot Swap SSD No 12*
7SD7A05779 B11C ThinkSystem U.2 Intel P4500 1.0TB Entry NVMe PCIe3.0 x4 Hot Swap SSD No 24
7SD7A05778 B11D ThinkSystem U.2 Intel P4500 2.0TB Entry NVMe PCIe3.0 x4 Hot Swap SSD No 24
7SD7A05777 B11E ThinkSystem U.2 Intel P4500 4.0TB Entry NVMe PCIe3.0 x4 Hot Swap SSD No 24

* Not supported in the configurations with 16/20/24x 2.5" U.2 NVMe PCIe drive bays.

Note: NVMe PCIe SSDs support surprise hot removal and hot insertion, provided the operating system supports PCIe SSD hot-swap.

Table 42. 3.5-inch hot-swap 12 Gb SAS HDDs
Part number Feature
code
Description SED
support
Max
Qty
3.5-inch hot-swap HDDs - 12 Gb SAS 10K
7XB7A00063 B1JJ ThinkSystem 3.5" 300GB 10K SAS 12Gb Hot Swap 512n HDD No 14
4XB7A77004 BK12 ThinkSystem 3.5" 1.2TB 10K SAS 12Gb Hot Swap 512n HDD No 14
3.5-inch hot-swap HDDs - 12 Gb SAS 15K
7XB7A00038 AUU2 ThinkSystem 3.5" 300GB 15K SAS 12Gb Hot Swap 512n HDD No 14
7XB7A00039 AUU3 ThinkSystem 3.5" 600GB 15K SAS 12Gb Hot Swap 512n HDD No 14
7XB7A00040 AUUC ThinkSystem 3.5" 900GB 15K SAS 12Gb Hot Swap 512e HDD No 14
3.5-inch hot-swap HDDs - 12 Gb NL SAS
7XB7A00041 AUU4 ThinkSystem 3.5" 1TB 7.2K SAS 12Gb Hot Swap 512n HDD No 14
7XB7A00042 AUU5 ThinkSystem 3.5" 2TB 7.2K SAS 12Gb Hot Swap 512n HDD No 14
7XB7A00043 AUU6 ThinkSystem 3.5" 4TB 7.2K SAS 12Gb Hot Swap 512n HDD No 14
7XB7A00044 AUU7 ThinkSystem 3.5" 6TB 7.2K SAS 12Gb Hot Swap 512e HDD No 14
7XB7A00045 B0YR ThinkSystem 3.5" 8TB 7.2K SAS 12Gb Hot Swap 512e HDD No 14
7XB7A00046 AUUG ThinkSystem 3.5" 10TB 7.2K SAS 12Gb Hot Swap 512e HDD No 14
7XB7A00067 B117 ThinkSystem 3.5" 12TB 7.2K SAS 12Gb Hot Swap 512e HDD No 14
4XB7A13906 B496 ThinkSystem 3.5" 14TB 7.2K SAS 12Gb Hot Swap 512e HDD No 14
4XB7A13911 B7EZ ThinkSystem 3.5" 16TB 7.2K SAS 12Gb Hot Swap 512e HDD No 14
4XB7A38266 BCFP ThinkSystem 3.5" 18TB 7.2K SAS 12Gb Hot Swap 512e HDD No 14
4XB7A80353 BPKU ThinkSystem 3.5" 20TB 7.2K SAS 12Gb Hot Swap 512e HDD No 14
3.5-inch hot-swap SED HDDs - 12 Gb NL SAS
7XB7A00065 B0YN ThinkSystem 3.5" 2TB 7.2K SAS 12Gb Hot Swap 512e HDD FIPS Support 14
7XB7A00047 AUUH ThinkSystem 3.5" 4TB 7.2K SAS 12Gb Hot Swap 512n HDD FIPS Support 14
7XB7A00048 B0YP ThinkSystem 3.5" 6TB 7.2K SAS 12Gb Hot Swap 512e HDD FIPS Support 14
7XB7A00066 B0YQ ThinkSystem 3.5" 8TB 7.2K SAS 12Gb Hot Swap 512e HDD FIPS Support 14
Table 43. 3.5-inch hot-swap 6 Gb SATA HDDs
Part number Feature
code
Description SED
support
Max
Qty
3.5-inch hot-swap HDDs - 6 Gb NL SATA
7XB7A00049 AUUF ThinkSystem 3.5" 1TB 7.2K SATA 6Gb Hot Swap 512n HDD No 14
7XB7A00050 AUUD ThinkSystem 3.5" 2TB 7.2K SATA 6Gb Hot Swap 512n HDD No 14
7XB7A00051 AUU8 ThinkSystem 3.5" 4TB 7.2K SATA 6Gb Hot Swap 512n HDD No 14
7XB7A00052 AUUA ThinkSystem 3.5" 6TB 7.2K SATA 6Gb Hot Swap 512e HDD No 14
7XB7A00053 AUU9 ThinkSystem 3.5" 8TB 7.2K SATA 6Gb Hot Swap 512e HDD No 14
7XB7A00054 AUUB ThinkSystem 3.5" 10TB 7.2K SATA 6Gb Hot Swap 512e HDD No 14
7XB7A00068 B118 ThinkSystem 3.5" 12TB 7.2K SATA 6Gb Hot Swap 512e HDD No 14
4XB7A13907 B497 ThinkSystem 3.5" 14TB 7.2K SATA 6Gb Hot Swap 512e HDD No 14
4XB7A13914 B7F0 ThinkSystem 3.5" 16TB 7.2K SATA 6Gb Hot Swap 512e HDD No 14
4XB7A38130 BCFH ThinkSystem 3.5" 18TB 7.2K SATA 6Gb Hot Swap 512e HDD No 14
4XB7A80354 BPKV ThinkSystem 3.5" 20TB 7.2K SATA 6Gb Hot Swap 512e HDD No 14
Table 44. 3.5-inch hot-swap 24 Gb SAS SSDs
Part number Feature
code
Description SED
support
Max
Qty
3.5-inch hot-swap SSDs - 24 Gb SAS - Mixed Use/Mainstream (3-5 DWPD)
4XB7A80344 BNW7 ThinkSystem 3.5" PM1655 800GB Mixed Use SAS 24Gb HS SSD Support 14
4XB7A80345 BNWA ThinkSystem 3.5" PM1655 1.6TB Mixed Use SAS 24Gb HS SSD Support 14
4XB7A80346 BNWB ThinkSystem 3.5" PM1655 3.2TB Mixed Use SAS 24Gb HS SSD Support 14
4XB7A80347 BP3G ThinkSystem 3.5" PM1655 6.4TB Mixed Use SAS 24Gb HS SSD Support 14
3.5-inch hot-swap SSDs - 24 Gb SAS - Read Intensive/Entry/Capacity (<3 DWPD)
4XB7A80324 BNWD ThinkSystem 3.5" PM1653 960GB Read Intensive SAS 24Gb HS SSD Support 14
4XB7A80325 BNWG ThinkSystem 3.5" PM1653 1.92TB Read Intensive SAS 24Gb HS SSD Support 14
4XB7A80326 BNWH ThinkSystem 3.5" PM1653 3.84TB Read Intensive SAS 24Gb HS SSD Support 14
4XB7A80327 BP3F ThinkSystem 3.5" PM1653 7.68TB Read Intensive SAS 24Gb HS SSD Support 14
4XB7A80328 BP3H ThinkSystem 3.5" PM1653 15.36TB Read Intensive SAS 24Gb HS SSD Support 14
Table 45. 3.5-inch hot-swap 12 Gb SAS SSDs
Part number Feature
code
Description SED
support
Max
Qty
3.5-inch hot-swap SSDs - 12 Gb SAS - Write Intensive/Performance (10+ DWPD)
4XB7A83219 BR0V ThinkSystem 3.5" Nytro 3750 800GB Write Intensive SAS 12Gb HS SSD Support 14
4XB7A83220 BR0U ThinkSystem 3.5" Nytro 3750 1.6TB Write Intensive SAS 12Gb HS SSD Support 14
4XB7A83221 BR0T ThinkSystem 3.5" Nytro 3750 3.2TB Write Intensive SAS 12Gb HS SSD Support 14
4XB7A70011 BG03 ThinkSystem 3.5" Nytro 3732 400GB Performance SAS 12Gb Hot Swap SSD No 14
4XB7A70010 BG02 ThinkSystem 3.5" Nytro 3732 800GB Performance SAS 12Gb Hot Swap SSD No 14
4XB7A70009 BG01 ThinkSystem 3.5" Nytro 3732 1.6TB Performance SAS 12Gb Hot Swap SSD No 14
4XB7A70008 BG00 ThinkSystem 3.5" Nytro 3732 3.2TB Performance SAS 12Gb Hot Swap SSD No 14
4XB7A10234 B4Y8 ThinkSystem 3.5" SS530 800GB Performance SAS 12Gb Hot Swap SSD No 14
4XB7A10235 B4Y9 ThinkSystem 3.5" SS530 1.6TB Performance SAS 12Gb Hot Swap SSD No 14
4XB7A10236 B4YA ThinkSystem 3.5" SS530 3.2TB Performance SAS 12Gb Hot Swap SSD No 14
7N47A00997 B16Z ThinkSystem 3.5" HUSMM32 400GB Performance SAS 12Gb Hot Swap SSD No 14
7N47A00998 B170 ThinkSystem 3.5" HUSMM32 800GB Performance SAS 12Gb Hot Swap SSD No 14
7N47A00999 B171 ThinkSystem 3.5" HUSMM32 1.6TB Performance SAS 12Gb Hot Swap SSD No 14
7SD7A05751 B11S ThinkSystem 3.5" HUSMM32 400GB Performance SAS 12Gb Hot Swap SSD FIPS Support 14
7SD7A05750 B11T ThinkSystem 3.5" HUSMM32 800GB Performance SAS 12Gb Hot Swap SSD FIPS Support 14
7SD7A05749 B11U ThinkSystem 3.5" HUSMM32 1.6TB Performance SAS 12Gb Hot Swap SSD FIPS Support 14
3.5-inch hot-swap SSDs - 12 Gb SAS - Mixed Use/Mainstream (3-5 DWPD)
4XB7A17066 B8HT ThinkSystem 3.5" PM1645a 800GB Mainstream SAS 12Gb Hot Swap SSD No 14
4XB7A17043 B8JN ThinkSystem 3.5" PM1645a 1.6TB Mainstream SAS 12Gb Hot Swap SSD No 14
4XB7A17067 B8JK ThinkSystem 3.5" PM1645a 3.2TB Mainstream SAS 12Gb Hot Swap SSD No 14
4XB7A17068 B8JG ThinkSystem 3.5" PM1645a 6.4TB Mainstream SAS 12Gb Hot Swap SSD No 14
4XB7A13657 B4A3 ThinkSystem 3.5" PM1645 800GB Mainstream SAS 12Gb Hot Swap SSD No 14
4XB7A13658 B4A4 ThinkSystem 3.5" PM1645 1.6TB Mainstream SAS 12Gb Hot Swap SSD No 14
4XB7A13659 B4A5 ThinkSystem 3.5" PM1645 3.2TB Mainstream SAS 12Gb Hot Swap SSD No 14
4XB7A10188 B2XD ThinkSystem 3.5" PM1635a 800GB Mainstream SAS 12Gb Hot Swap SSD No 14
4XB7A10187 B2XE ThinkSystem 3.5" PM1635a 1.6TB Mainstream SAS 12Gb Hot Swap SSD No 14
4XB7A10189 B2XL ThinkSystem 3.5" PM1635a 3.2TB Mainstream SAS 12Gb Hot Swap SSD No 14
3.5-inch hot-swap SSDs - 12 Gb SAS - Read Intensive/Entry/Capacity (<3 DWPD)
4XB7A17058 B91E ThinkSystem 3.5" PM1643a 3.84TB Entry SAS 12Gb Hot Swap SSD No 14
4XB7A17059 BEVK ThinkSystem 3.5" PM1643a 7.68TB Entry SAS 12Gb Hot Swap SSD No 14
4XB7A13649 B4A8 ThinkSystem 3.5" PM1643 3.84TB Capacity SAS 12Gb Hot Swap SSD No 14
4XB7A10173 B2XC ThinkSystem 3.5" PM1633a 3.84TB Capacity SAS 12Gb Hot Swap SSD No 14
Table 46. 3.5-inch hot-swap 6 Gb SATA SSDs
Part number Feature
code
Description SED
support
Max
Qty
3.5-inch hot-swap SSDs - 6 Gb SATA - Mixed Use/Mainstream (3-5 DWPD)
4XB7A17137 BA4W ThinkSystem 3.5" S4620 480GB Mixed Use SATA 6Gb HS SSD No 14
4XB7A17138 BA4X ThinkSystem 3.5" S4620 960GB Mixed Use SATA 6Gb HS SSD No 14
4XB7A17139 BA4Y ThinkSystem 3.5" S4620 1.92TB Mixed Use SATA 6Gb HS SSD No 14
4XB7A17140 BK7P ThinkSystem 3.5" S4620 3.84TB Mixed Use SATA 6Gb HS SSD No 14
4XB7A17096 B8JL ThinkSystem 3.5" 5300 240GB Mainstream SATA 6Gb Hot Swap SSD No 14
4XB7A17097 B8JF ThinkSystem 3.5" 5300 480GB Mainstream SATA 6Gb Hot Swap SSD No 14
4XB7A17098 B8J0 ThinkSystem 3.5" 5300 960GB Mainstream SATA 6Gb Hot Swap SSD No 14
4XB7A17099 B8HR ThinkSystem 3.5" 5300 1.92TB Mainstream SATA 6Gb Hot Swap SSD No 14
4XB7A17100 B8HX ThinkSystem 3.5" 5300 3.84TB Mainstream SATA 6Gb Hot Swap SSD No 14
4XB7A13639 B49R ThinkSystem 3.5" S4610 240GB Mixed Use SATA 6Gb HS SSD No 14
4XB7A13640 B49S ThinkSystem 3.5" S4610 480GB Mixed Use SATA 6Gb HS SSD No 14
4XB7A13641 B49T ThinkSystem 3.5" S4610 960GB Mixed Use SATA 6Gb HS SSD No 14
4XB7A13642 B49U ThinkSystem 3.5" S4610 1.92TB Mixed Use SATA 6Gb HS SSD No 14
4XB7A13643 B49V ThinkSystem 3.5" S4610 3.84TB Mixed Use SATA 6Gb HS SSD No 14
4XB7A10242 B48D ThinkSystem 3.5" 5200 240GB Mainstream SATA 6Gb Hot Swap SSD No 14
4XB7A10243 B48E ThinkSystem 3.5" 5200 480GB Mainstream SATA 6Gb Hot Swap SSD No 14
4XB7A10244 B48F ThinkSystem 3.5" 5200 960GB Mainstream SATA 6Gb Hot Swap SSD No 14
4XB7A10245 B48G ThinkSystem 3.5" 5200 1.92TB Mainstream SATA 6Gb Hot Swap SSD No 14
4XB7A10246 B48H ThinkSystem 3.5" 5200 3.84TB Mainstream SATA 6Gb Hot Swap SSD No 14
7SD7A05718 B0ZT ThinkSystem 3.5" Intel S4600 240GB Mainstream SATA 6Gb Hot Swap SSD No 14
7SD7A05717 B0ZU ThinkSystem 3.5" Intel S4600 480GB Mainstream SATA 6Gb Hot Swap SSD No 14
7SD7A05716 B0ZV ThinkSystem 3.5" Intel S4600 960GB Mainstream SATA 6Gb Hot Swap SSD No 14
7SD7A05715 B109 ThinkSystem 3.5" Intel S4600 1.92TB Mainstream SATA 6Gb Hot Swap SSD No 14
7SD7A05760 B111 ThinkSystem 3.5" 5100 240GB Mainstream SATA 6Gb Hot Swap SSD No 14
7SD7A05759 B112 ThinkSystem 3.5" 5100 480GB Mainstream SATA 6Gb Hot Swap SSD No 14
7SD7A05758 B113 ThinkSystem 3.5" 5100 960GB Mainstream SATA 6Gb Hot Swap SSD No 14
7SD7A05757 B114 ThinkSystem 3.5" 5100 1.92TB Mainstream SATA 6Gb Hot Swap SSD No 14
7SD7A05756 B115 ThinkSystem 3.5" 5100 3.84TB Mainstream SATA 6Gb Hot Swap SSD No 14
3.5-inch hot-swap SSDs - 6 Gb SATA - Read Intensive/Entry (<3 DWPD)
4XB7A88456 BW3S ThinkSystem 3.5" 5400 PRO 480GB Read Intensive SATA 6Gb HS SSD Support 14
4XB7A17118 BA7K ThinkSystem 3.5" S4520 240GB Read Intensive SATA 6Gb HS SSD No 14
4XB7A17119 BA7L ThinkSystem 3.5" S4520 480GB Read Intensive SATA 6Gb HS SSD No 14
4XB7A17120 BA7M ThinkSystem 3.5" S4520 960GB Read Intensive SATA 6Gb HS SSD No 14
4XB7A17121 BA7N ThinkSystem 3.5" S4520 1.92TB Read Intensive SATA 6Gb HS SSD No 14
4XB7A17122 BK7F ThinkSystem 3.5" S4520 3.84TB Read Intensive SATA 6Gb HS SSD No 14
4XB7A17123 BK7G ThinkSystem 3.5" S4520 7.68TB Read Intensive SATA 6Gb HS SSD No 14
4XB7A38276 BCTH ThinkSystem 3.5" Multi Vendor 240GB Entry SATA 6Gb Hot Swap SSD No 14
4XB7A38277 BCTJ ThinkSystem 3.5" Multi Vendor 480GB Entry SATA 6Gb Hot Swap SSD No 14
4XB7A38278 BCTK ThinkSystem 3.5" Multi Vendor 960GB Entry SATA 6Gb Hot Swap SSD No 14
4XB7A38279 BCTL ThinkSystem 3.5" Multi Vendor 1.92TB Entry SATA 6Gb Hot Swap SSD No 14
4XB7A38281 BCTM ThinkSystem 3.5" Multi Vendor 3.84TB Entry SATA 6Gb Hot Swap SSD No 14
4XB7A17081 B8JB ThinkSystem 3.5" 5300 240GB Entry SATA 6Gb Hot Swap SSD No 14
4XB7A17082 B8J9 ThinkSystem 3.5" 5300 480GB Entry SATA 6Gb Hot Swap SSD No 14
4XB7A17083 B8JC ThinkSystem 3.5" 5300 960GB Entry SATA 6Gb Hot Swap SSD No 14
4XB7A17084 B8HZ ThinkSystem 3.5" 5300 1.92TB Entry SATA 6Gb Hot Swap SSD No 14
4XB7A17085 B8HQ ThinkSystem 3.5" 5300 3.84TB Entry SATA 6Gb Hot Swap SSD No 14
4XB7A17086 B8J3 ThinkSystem 3.5" 5300 7.68TB Entry SATA 6Gb Hot Swap SSD No 14
4XB7A13625 B49D ThinkSystem 3.5" S4510 240GB Read Intensive SATA 6Gb HS SSD No 14
4XB7A13626 B49E ThinkSystem 3.5" S4510 480GB Read Intensive SATA 6Gb HS SSD No 14
4XB7A13627 B49F ThinkSystem 3.5" S4510 960GB Read Intensive SATA 6Gb HS SSD No 14
4XB7A13628 B49G ThinkSystem 3.5" S4510 1.92TB Read Intensive SATA 6Gb HS SSD No 14
4XB7A13629 B49H ThinkSystem 3.5" S4510 3.84TB Read Intensive SATA 6Gb HS SSD No 14
4XB7A17176 B6TM ThinkSystem 3.5" PM883 240GB Entry SATA 6Gb Hot Swap SSD No 14
4XB7A17177 B6TN ThinkSystem 3.5" PM883 480GB Entry SATA 6Gb Hot Swap SSD No 14
4XB7A17178 B6TP ThinkSystem 3.5" PM883 960GB Entry SATA 6Gb Hot Swap SSD No 14
4XB7A17179 B6JY ThinkSystem 3.5" PM883 1.92TB Entry SATA 6Gb Hot Swap SSD No 14
4XB7A17180 B6JZ ThinkSystem 3.5" PM883 3.84TB Entry SATA 6Gb Hot Swap SSD No 14
7N47A00115 AUUS ThinkSystem 3.5" PM863a 240GB Entry SATA 6Gb Hot Swap SSD No 14
7N47A00116 AUUN ThinkSystem 3.5" PM863a 480GB Entry SATA 6Gb Hot Swap SSD No 14
7N47A00106 AUUT ThinkSystem 3.5" Intel S3520 480GB Entry SATA 6Gb Hot Swap SSD No 14
7N47A00105 AUUW ThinkSystem 3.5" Intel S3520 240GB Entry SATA 6Gb Hot Swap SSD No 14
7SD7A05737 B0Z3 ThinkSystem 3.5" Intel S4500 240GB Entry SATA 6Gb Hot Swap SSD No 14
7SD7A05736 B0Z4 ThinkSystem 3.5" Intel S4500 480GB Entry SATA 6Gb Hot Swap SSD No 14
7SD7A05735 B0Z5 ThinkSystem 3.5" Intel S4500 960GB Entry SATA 6Gb Hot Swap SSD No 14
7SD7A05734 B0Z6 ThinkSystem 3.5" Intel S4500 1.92TB Entry SATA 6Gb Hot Swap SSD No 14
7SD7A05733 B0Z7 ThinkSystem 3.5" Intel S4500 3.84TB Entry SATA 6Gb Hot Swap SSD No 14
4XB7A10158 B2X7 ThinkSystem 3.5" 5200 480GB Entry SATA 6Gb Hot Swap SSD No 14
4XB7A10159 B2X8 ThinkSystem 3.5" 5200 960GB Entry SATA 6Gb Hot Swap SSD No 14
4XB7A10160 B2X9 ThinkSystem 3.5" 5200 1.92TB Entry SATA 6Gb Hot Swap SSD No 14
4XB7A10161 B2XA ThinkSystem 3.5" 5200 3.84TB Entry SATA 6Gb Hot Swap SSD No 14
4XB7A10162 B2XB ThinkSystem 3.5" 5200 7.68TB Entry SATA 6Gb Hot Swap SSD No 14
4XB7A08506 B10S ThinkSystem 3.5" 5100 480GB Entry SATA 6Gb Hot Swap SSD No 14
4XB7A08507 B10T ThinkSystem 3.5" 5100 960GB Entry SATA 6Gb Hot Swap SSD No 14
4XB7A08508 B10U ThinkSystem 3.5" 5100 1.92TB Entry SATA 6Gb Hot Swap SSD No 14
4XB7A08509 B10V ThinkSystem 3.5" 5100 3.84TB Entry SATA 6Gb Hot Swap SSD No 14
Table 47. 3.5-inch hot-swap PCIe 4.0 NVMe SSDs
Part number Feature
code
Description SED
support
Max
Qty
3.5-inch SSDs - U.2 PCIe 4.0 NVMe - Mixed Use/Mainstream (3-5 DWPD)
4XB7A17141 BNEK ThinkSystem 3.5" U.2 P5620 1.6TB Mixed Use NVMe PCIe 4.0 x4 HS SSD Support 4
4XB7A17143 BNEM ThinkSystem 3.5" U.2 P5620 3.2TB Mixed Use NVMe PCIe 4.0 x4 HS SSD Support 4
4XB7A17144 BNEN ThinkSystem 3.5" U.2 P5620 6.4TB Mixed Use NVMe PCIe 4.0 x4 HS SSD Support 4
4XB7A17155 BCFM ThinkSystem 3.5" U.2 P5600 1.6TB Mixed Use NVMe PCIe 4.0 x4 HS SSD No 4
4XB7A17156 BCFJ ThinkSystem 3.5" U.2 P5600 3.2TB Mixed Use NVMe PCIe 4.0 x4 HS SSD No 4
4XB7A17157 BCFQ ThinkSystem 3.5" U.2 P5600 6.4TB Mixed Use NVMe PCIe 4.0 x4 HS SSD No 4
3.5-inch SSDs - U.3 PCIe 4.0 NVMe - Mixed Use/Mainstream (3-5 DWPD)
4XB7A64176 BE04 ThinkSystem 3.5" Kioxia CM6-V 800GB Mainstream NVMe PCIe 4.0 x4 Hot Swap SSD No 4
4XB7A17115 B96V ThinkSystem 3.5" Kioxia CM6-V 1.6TB Mainstream NVMe PCIe4.0 x4 Hot Swap SSD No 4
4XB7A17116 B96K ThinkSystem 3.5" Kioxia CM6-V 3.2TB Mainstream NVMe PCIe4.0 x4 Hot Swap SSD No 4
4XB7A17117 B96W ThinkSystem 3.5" Kioxia CM6-V 6.4TB Mainstream NVMe PCIe4.0 x4 Hot Swap SSD No 4

Note: NVMe PCIe SSDs support surprise hot removal and hot insertion, provided the operating system supports PCIe SSD hot-swap.

Table 48. 3.5-inch hot-swap PCIe 3.0 NVMe SSDs
Part number Feature
code
Description SED
support
Max
Qty
3.5-inch SSDs - U.2 PCIe 3.0 NVMe - Mixed Use/Mainstream (3-5 DWPD)
4XB7A13944 B58C ThinkSystem 3.5" Intel P4610 1.6TB Mainstream NVMe PCIe3.0 x4 Hot Swap SSD No 4
4XB7A13945 B58D ThinkSystem 3.5" Intel P4610 3.2TB Mainstream NVMe PCIe3.0 x4 Hot Swap SSD No 4
4XB7A13946 B58E ThinkSystem 3.5" Intel P4610 6.4TB Mainstream NVMe PCIe3.0 x4 Hot Swap SSD No 4
4XB7A08532 B21Z ThinkSystem 3.5" Toshiba CM5-V 800GB Mainstream NVMe PCIe 3.0 x4 Hot Swap SSD No 4
4XB7A08533 B220 ThinkSystem 3.5" Toshiba CM5-V 1.6TB Mainstream NVMe PCIe 3.0 x4 Hot Swap SSD No 4
4XB7A08534 B221 ThinkSystem 3.5" Toshiba CM5-V 3.2TB Mainstream NVMe PCIe 3.0 x4 Hot Swap SSD No 4
4XB7A08535 B2XK ThinkSystem 3.5" Toshiba CM5-V 6.4TB Mainstream NVMe PCIe 3.0 x4 Hot Swap SSD No 4
4XB7A08528 B2XF ThinkSystem 3.5" Intel P4600 1.6TB Mainstream NVMe PCIe3.0 x4 Hot Swap SSD No 4
4XB7A08529 B2XG ThinkSystem 3.5" Intel P4600 3.2TB Mainstream NVMe PCIe3.0 x4 Hot Swap SSD No 4
4XB7A08530 B2XH ThinkSystem 3.5" Intel P4600 6.4TB Mainstream NVMe PCIe3.0 x4 Hot Swap SSD No 4
7N47A00982 AUUM ThinkSystem 3.5" PX04PMB 960GB Mainstream NVMe PCIe 3.0 x4 Hot Swap SSD No 4
3.5-inch SSDs - U.2 PCIe 3.0 NVMe - Read Intensive/Entry (<3 DWPD)
4XB7A10178 B34Q ThinkSystem 3.5" PM983 1.92TB Entry NVMe PCIe 3.0 x4 Hot Swap SSD No 4
4XB7A10179 B34R ThinkSystem 3.5" PM983 3.84TB Entry NVMe PCIe 3.0 x4 Hot Swap SSD No 4
4XB7A10180 B4D4 ThinkSystem 3.5" PM983 7.68TB Entry NVMe PCIe3.0 x4 Hot Swap SSD No 4
7N47A00987 AUUX ThinkSystem 3.5" PM963 1.92TB Entry NVMe PCIe 3.0 x4 Hot Swap SSD No 4
7N47A00988 AUVZ ThinkSystem 3.5" PM963 3.84TB Entry NVMe PCIe 3.0 x4 Hot Swap SSD No 4

Note: NVMe PCIe SSDs support surprise hot removal and hot insertion, provided the operating system supports PCIe SSD hot-swap.

Table 49. M.2 SATA drives
Part number Feature
code
Description SED
support
Max
Qty
M.2 SSDs - 6 Gb SATA - Read Intensive/Entry (<3 DWPD)
4XB7A90105 BXMK ThinkSystem M.2 ER2 240GB Read Intensive SATA 6Gb NHS SSD (China only) Support 2*
4XB7A90106 BXMJ ThinkSystem M.2 ER2 480GB Read Intensive SATA 6Gb NHS SSD (China only) Support 2*
4XB7A82286 BQ1Z ThinkSystem M.2 5400 PRO 240GB Read Intensive SATA 6Gb NHS SSD Support 2*
4XB7A82287 BQ1Y ThinkSystem M.2 5400 PRO 480GB Read Intensive SATA 6Gb NHS SSD Support 2*
7N47A00129 AUUL ThinkSystem M.2 32GB SATA 6Gbps Non-Hot Swap SSD No 2
7N47A00130 AUUV ThinkSystem M.2 128GB SATA 6Gbps Non-Hot Swap SSD No 2
4XB7A14049 B5S4 ThinkSystem M.2 5100 240GB SATA 6Gbps Non-Hot Swap SSD No 2*
7SD7A05703 B11V ThinkSystem M.2 5100 480GB SATA 6Gbps Non-Hot Swap SSD No 2*
4XB7A17071 B8HS ThinkSystem M.2 5300 240GB SATA 6Gbps Non-Hot Swap SSD No 2*
4XB7A17073 B919 ThinkSystem M.2 5300 480GB SATA 6Gbps Non-Hot Swap SSD No 2*

* The 5100, 5300, 5400 M.2 or ER2 drives may require the SSD Thermal Kit, 4XH7A08791. See the Cooling section for details.

USB flash drive

For general portable storage needs, the server also supports the USB flash drive option that is listed in the following table.

Table 50. USB memory key
Part number Feature Description
4X77A08621 B8NV ThinkSystem 32GB USB Flash Drive

Optical drives

The server supports the external USB optical drive listed in the following table.

Table 51. External optical drive
Part number Feature code Description
7XA7A05926 AVV8 ThinkSystem External USB DVD RW Optical Disk Drive

The drive is based on the Lenovo Slim DVD Burner DB65 drive and supports the following formats: DVD-RAM, DVD-RW, DVD+RW, DVD+R, DVD-R, DVD-ROM, DVD-R DL, CD-RW, CD-R, CD-ROM.

I/O expansion

The SR650 server supports one LOM card slot and up to seven PCIe slots: one slot on the system planar that is dedicated to an internal storage controller, one regular PCIe slot on the system planar, and up to five PCIe slots with different riser cards installed into two riser sockets on the system planar (one riser socket supports installation of one riser card).

The slot form factors are as follows:

  • LOM card slot
  • Slot 1: PCIe 3.0 x16 or PCIe 3.0 x8; full-height, half-length (PCIe x16 slot can be single- or double-wide)
  • Slot 2: PCIe 3.0 x8; full-height, half-length (not present if Slot 1 is PCIe x16 double-wide or Slot 3 is ML2 x16)
  • Slot 3: PCIe 3.0 x8, or PCIe 3.0 x16, or ML2 x8, or ML2 x16; full-height, half-length
  • Slot 4: PCIe 3.0 x8; low profile (vertical slot on system planar)
  • Slot 5: PCIe 3.0 x16; full-height, half-length
  • Slot 6: PCIe 3.0 x16; full-height, half-length
  • Slot 7: PCIe 3.0 x8 (for an internal storage controller)

Configuration notes:

  • Slots 5 and 6 require the second processor to be installed.
  • Single-wide PCIe 3.0 x16 Slot 1 requires the second processor to be installed.
  • The following configurations require the single-wide PCIe 3.0 x16 Slot 1:
    • 24 NVMe PCIe drive bays.
    • Two double-wide GPUs and one PCIe x16 adapter.
  • Slots 1 - 3 are not present if the Rear HDD Kit is installed.
  • Slots 1, 5, and 6 can be enabled for full-length PCIe adapters (such as GPU adapters):
    • Factory-installed GPUs: When a GPU adapter is selected, all required parts are derived.
    • Factory-enabled full-length support (no adapters included): Select the feature code B3RY, and all required parts will be derived based on the number of processors and PCIe riser cards selected.
    • Field upgrades: Refer to Cooling for upgrade kit requirements.

The locations of the PCIe slots are shown in the following figure.

Slot locations
Figure 11. Slot locations

Riser 1 supplies slots 1, 2, and 3, and Riser 2 supplies slots 5 and 6. The slots that are available for use depend on the number of riser cards that are installed and whether the second processor is installed, as shown in the following table.

Table 52. Slots available for use
Riser Card 1 Riser Card 2 Slots available for use
Processor 1 Processor 2
None None LOM, 4, 7 -
None PCIe x16/x16 LOM, 4, 7 5, 6
PCIe x8/x8/x8 or
PCIe x8/x8/x8ML2
None LOM, 1, 2, 3, 4, 7 -
PCIe x16/x8 or
PCIe x8/x16ML2
None LOM, 1, 3, 4, 7 -
PCIe x8/x8/x8 or
PCIe x8/x8/x8ML2
PCIe x16/x16 LOM, 1, 2, 3, 4, 7 5, 6
PCIe x16/x8 or
PCIe x8/x16ML2
PCIe x16/x16 LOM, 1, 3, 4, 7 5, 6
PCIe x16/x8/x16 PCIe x16/x16 LOM, 2, 3, 4, 7 1, 5, 6

The following table lists available PCIe riser card options.

Table 53. PCIe riser cards and miscellaneous options
Part number Feature code Description Maximum quantity
x8 Riser Card 1 options (Riser card 1 supplies slots 1, 2, and 3)
7XH7A02677 AUR4 ThinkSystem 2U x8/x8/x8 PCIe FH Riser 1 1
7XH7A02680 AUR7 ThinkSystem 2U x8/x8/x8ML2 PCIe FH Riser 1 1
4XH7A09902 B4PB ThinkSystem SR650 x16/x8/x16 PCIe FH Riser 1 1
x16 Riser Card 1 options (Riser card 1 supplies slots 1 and 3)
7XH7A02678 AUR3 ThinkSystem 2U x16/x8 PCIe FH Riser 1 1
7XH7A02681 AURB ThinkSystem SR650 x8/x16ML2 PCIe FH Riser 1 Kit 1
Riser Card 2 option (Riser card 2 supplies slots 5 and 6)
4TA7A70026 None ThinkSystem SR650 x16/x8(or x16) PCIe FH Riser 2 Kit V2 1
7XH7A02679 AURC ThinkSystem SR550/SR650 (x16/x8)/(x16/x16) PCIe FH Riser 2 Kit 1
Serial port upgrade kit
4Z17A80446 BMNJ ThinkSystem COM Port Upgrade Kit v2 1
7Z17A02577 AUSL ThinkSystem COM Port Upgrade Kit 1

Configuration notes:

  • If the PCIe x16/x8/x16 Riser Card (4XH7A09902) is installed, the onboard NVMe interface cannot be used for connections to U.2 NVMe or AnyBay drive bays.
  • In the configurations with 16x 2.5-inch U.2 NVMe PCIe drive bays, the PCIe 3.0 x8 Slot 3 and PCIe 3.0 x16 Slot 5 are available, and the remaining slots are occupied by the NVMe switch adapters.
    Note: If the additional 8-bay SAS/SATA backplane is installed, only the PCIe 3.0 x16 Slot 5 is available (the PCIe 3.0 x8 Slot 3 is occupied by an internal storage controller).
  • In the configurations with 20x 2.5-inch U.2 NVMe PCIe drive bays, the PCIe 3.0 x8 Slot 3 is available, and the remaining slots are occupied by the NVMe switch adapters.
  • In the configurations with 24x 2.5-inch U.2 NVMe PCIe drive bays, the PCIe 3.0 x16 Slots 3 and 5 are available, and the remaining slots are occupied by the NVMe switch adapters.
  • For field upgrades to add an NVIDIA A-Series GPU (A100, A6000, A30, A16, A10, A2), the use of Riser 2 V2 riser kit (4TA7A70026) is required when the GPU is to be installed in slot 5. The older Riser 2 kit (7XH7A02679, now withdrawn) is not supported with the A100. For CTO orders, feature code BF9Y will be used for the correct Riser 2 bracket.
  • The COM Port Upgrade Kit, part number 7Z17A02577, is used for mounting the external serial port on the rear of the SR650 server, and it includes the bracket and the cable. The COM Port option is mounted in place of one of the PCIe slots 1 - 6, and that PCIe slot cannot be used.

Network adapters

The SR650 server supports up to four onboard network ports with optional LOM cards that use the Intel Ethernet Connection X722 1/10 GbE technology integrated into the Intel C624 Platform Controller Hub (PCH). The server also supports ML2 adapters that are installed in the custom ML2 slot provided by an ML2 riser card. The LOM cards and ML2 network adapters support direct connectivity to the XClarity Controller via the Network Controller Sideband Interface (NSCI) for out-of-band systems management.

The integrated Intel Ethernet Connection X722 has the following features:

  • Four 1/10 Gb Ethernet capable ports (no 10/100 Mb Ethernet support)
  • NIC Teaming (load balancing and failover)
  • Data Center Bridging
  • iWARP (RDMA over IP)
  • VMDq and SR-IOV virtualization (10 Gb speeds only, 4 PFs, 128 VFs per device)
  • IEEE 802.1q Virtual Local Area Networks (VLANs)
  • NVGRE, VXLAN, IPinGRE, and MACinUDP network virtualization
  • IEEE 802.1Qbg Edge Virtual Bridging
  • TCP, IP, and UDP checksum offload
  • Large Send Offload (LSO) and Generic Send Offload (GSO)
  • Receive Side Scaling (RSS) for TCP and UDP traffic
  • Jumbo frames up to 9.5 Kbytes

The following table lists the network adapters that are supported with the SR650 server.

Table 54. Network adapters
Part
number
Feature
code
Description Max
qty#
I/O slots
supported
LOM cards - 1 Gb Ethernet
7ZT7A00544 AUKG ThinkSystem 1Gb 2-port RJ45 LOM 1 LOM slot
7ZT7A00545 AUKH ThinkSystem 1Gb 4-port RJ45 LOM 1 LOM slot
LOM cards - 10 Gb Ethernet
7ZT7A00548 AUKL ThinkSystem 10Gb 2-port Base-T LOM 1 LOM slot
7ZT7A00546 AUKJ ThinkSystem 10Gb 2-port SFP+ LOM 1* LOM slot
7ZT7A00549 AUKM ThinkSystem 10Gb 4-port Base-T LOM 1 LOM slot
7ZT7A00547 AUKK ThinkSystem 10Gb 4-port SFP+ LOM 1* LOM slot
ML2 adapters - 10 Gb Ethernet
7ZT7A00497 AUKQ Broadcom NX-E ML2 10Gb 2-Port Base-T Ethernet Adapter 1 3 (ML2)
00AG560 AT7U Emulex VFA5.2 ML2 Dual Port 10GbE SFP+ Adapter 1* 3 (ML2)
01CV770 AU7Z Emulex VFA5.2 ML2 2x10 GbE SFP+ Adapter and FCoE/iSCSI SW 1* 3 (ML2)
00JY940 ATRH Intel X710-DA2 ML2 2x10GbE SFP+ Adapter 1* 3 (ML2)
ML2 adapters - 25 Gb Ethernet
00MN990 ATZR Mellanox ConnectX-4 Lx 10/25GbE SFP28 1-port ML2 Ethernet Adapter 1* 3 (ML2)
7ZT7A00507 AUKU Mellanox ConnectX-4 Lx 10/25GbE SFP28 2-port ML2 Ethernet Adapter 1* 3 (ML2)
ML2 adapters - FDR InfiniBand
7ZT7A00501 AUKR Mellanox ConnectX-3 Pro ML2 FDR 2-Port QSFP VPI Adapter 1* 3 (ML2)
PCIe Low Profile adapters - 1 Gb Ethernet
7ZT7A00482 AUZX Broadcom 5720 1GbE RJ45 2-Port PCIe Ethernet Adapter 4 / 6 4, 2, 6, 3, 5, 1
7ZT7A00484 AUZV Broadcom 5719 1GbE RJ45 4-Port PCIe Ethernet Adapter 4 / 6 4, 2, 6, 3, 5, 1
7ZT7A00533 AUZZ ThinkSystem I350-F1 PCIe 1Gb 1-Port SFP Ethernet Adapter 4 / 6 4, 2, 6, 3, 5, 1
7ZT7A00534 AUZY ThinkSystem I350-T2 PCIe 1Gb 2-Port RJ45 Ethernet Adapter 4 / 6 4, 2, 6, 3, 5, 1
7ZT7A00535 AUZW ThinkSystem I350-T4 PCIe 1Gb 4-Port RJ45 Ethernet Adapter 4 / 6 4, 2, 6, 3, 5, 1
4XC7A62589§ BE8A§ SiNEAD I350-C4 PCIe 1Gb 4-Port RJ45 Ethernet Adapter 4 / 6 4, 2, 6, 3, 5, 1
PCIe Low Profile adapters - 10 Gb Ethernet
7ZT7A00496 AUKP Broadcom 57416 10GBASE-T 2-Port PCIe Ethernet Adapter 4 / 6 4, 2, 6, 3, 5, 1
00AG570 AT7S Emulex VFA5.2 2x10 GbE SFP+ PCIe Adapter 4 / 6* 4, 2, 6, 3, 5, 1
00AG580 AT7T Emulex VFA5.2 2x10 GbE SFP+ Adapter and FCoE/iSCSI SW 4 / 6* 4, 2, 6, 3, 5, 1
00MM860 ATPX Intel X550-T2 Dual Port 10GBase-T Adapter 4 / 6 4, 2, 6, 3, 5, 1
7ZT7A00537 AUKX Intel X710-DA2 PCIe 10Gb 2-Port SFP+ Ethernet Adapter 4 / 6* 4, 2, 6, 3, 5, 1
4XC7A79699 BMXB ThinkSystem Intel X710-T4L 10GBase-T 4-Port PCIe Ethernet Adapter 4 / 6 4, 2, 6, 3, 5, 1
4XC7A08225 B31G QLogic QL41134 PCIe 10Gb 4-Port Base-T Ethernet Adapter 4 / 6 4, 2, 6, 3, 5, 1
PCIe Full Height adapters - 10 Gb Ethernet
7ZT7A00493 AUKN Emulex OCe14104B-NX PCIe 10Gb 4-Port SFP+ Ethernet Adapter 3 / 5* 2, 6, 3, 5, 1
PCIe Low Profile adapters - 25 Gb Ethernet
7ZT7A00505 AUKS Broadcom 57412 10/25GbE SFP28 1-Port PCIe Ethernet Adapter 4 / 6* 4, 2, 6, 3, 5, 1
4XC7A08238 B5T0 Broadcom 57414 10/25GbE SFP28 2-port PCIe Ethernet Adapter 4 / 6* 4, 2, 6, 3, 5, 1
4XC7A08316 BD49 Broadcom 57454 10/25GbE SFP28 4-port PCIe Ethernet Adapter V2 1 / 3* 1, 6, 5, 3
4XC7A08295 BCD6 Intel E810-DA2 10/25GbE SFP28 2-Port PCIe Ethernet Adapter 4 / 6* 4, 2, 6, 3, 5, 1
7XC7A05523 B0WY Intel XXV710-DA2 10/25GbE SFP28 2-Port PCIe Ethernet Adapter 4 / 6* 4, 2, 6, 3, 5, 1
4XC7A08270 B652 Marvell QL41232 10/25GbE SFP28 2-Port PCIe Ethernet Adapter 4 / 6* 4, 2, 6, 3, 5, 1
01GR250 AUAJ Mellanox ConnectX-4 Lx 10/25GbE SFP28 2-Port PCIe Ethernet Adapter 4 / 6* 4, 2, 6, 3, 5, 1
4XC7A62574 BEAP Mellanox ConnectX-5 EN 10/25GbE SFP28 2-port PCIe Ethernet Adapter 4 / 6* 4, 2, 6, 3, 5, 1
4XC7A16683 B5XZ Mellanox Innova-2 ConnectX-5 FPGA 25GbE 2-port Adapter 1 / 3* 1, 5, 6†
4XC7A62580 BE4U Mellanox ConnectX-6 Lx 10/25GbE SFP28 2-Port PCIe Ethernet Adapter 4 / 6* 4, 2, 6, 3, 5, 1
4XC7A08228 B21R QLogic QL41262 10/25GbE SFP28 2-Port PCIe Ethernet Adapter 4 / 6* 4, 2, 6, 3, 5, 1
4XC7A62581 BHE2 Solarflare X2522-Plus 10/25GbE SFP28 2-Port PCIe Ethernet Adapter 4 / 6* 4, 2, 6, 3, 5, 1
PCIe Low Profile adapters - 40 Gb Ethernet
00MM950 ATRN Mellanox ConnectX-4 Lx 1x40GbE QSFP+ Adapter 4 / 6* 4, 2, 6, 3, 5, 1
4XC7A08229 B31C Mellanox ConnectX-5 Ex 25/40GbE 2-port Low-Latency Adapter 1 / 3*^ 1, 5, 6†
PCIe Low Profile adapters - FDR InfiniBand
7XC7A05524 B0WX Mellanox ConnectX-4 PCIe FDR 1-Port QSFP VPI Adapter 4 / 6* 4, 2, 6, 3, 5, 1
7ZT7A00500 AUVG Mellanox ConnectX-4 PCIe FDR 2-Port QSFP VPI Adapter 4 / 6* 4, 2, 6, 3, 5, 1
PCIe x16 Low Profile adapters - 100 Gb Ethernet
00KH924 ASWQ Mellanox ConnectX-4 1x100GbE/EDR IB QSFP28 VPI Adapter 1 / 3* 1, 5, 6†
00MM960 ATRP Mellanox ConnectX-4 2x100GbE/EDR IB QSFP28 VPI Adapter 1 / 3* 1, 5, 6†
4XC7A08248 B8PP Mellanox ConnectX-6 Dx 100GbE QSFP56 2-port PCIe Ethernet Adapter 1 / 3* 1, 5, 6†
4XC7A76757 BLC2 ThinkSystem Xilinx Alveo U50 Data Center Accelerator Adapter 1 / 2* 1, 5¤
PCIe x16 Low Profile adapters - 100 Gb Ethernet / HDR100 InfiniBand
4C57A14177 B4R9 ThinkSystem Mellanox ConnectX-6 HDR100/100GbE QSFP56 1-port PCIe VPI Adapter 1 / 2* 1, 6, 5, 3†
4C57A14178 B4RA ThinkSystem Mellanox ConnectX-6 HDR100/100GbE QSFP56 2-port PCIe VPI Adapter 1 / 2* 1, 6, 5, 3†
PCIe x16 Low Profile adapters - 200 Gb Ethernet / HDR InfiniBand
4C57A15326 B4RC ThinkSystem Mellanox ConnectX-6 HDR/200GbE QSFP56 1-port PCIe 4 VPI Adapter 1 / 1* 1†‡
4C57A14179 B4RB Mellanox HDR/200GbE 2x PCIe Aux Kit 1 / 1* 5, 6†‡
PCIe Low Profile adapters - Omni-Path
00WE023 AU0A Intel OPA 100 Series Single-port PCIe 3.0 x8 HFA 4 / 6* 4, 2, 6, 3, 5, 1
00WE027 AU0B Intel OPA 100 Series Single-port PCIe 3.0 x16 HFA 1 / 3* 1, 5, 6†

# The maximum quantity shown is with one processor / two processors (this does not apply to LOM cards and ML2 adapters).
* The adapter comes without transceivers or cables; for ordering transceivers or cables, see the product guide for the adapter.
† The adapter is supported in the PCIe x16 slots supplied by the riser cards 1 and 2.
^ The 25 GbE connectivity requires the optional Mellanox QSA 100G to 25G Cable Adapter (4G17A10853) (one per port); the supported cables include 25 GbE passive DAC and active optical cables (25 GbE transceivers not supported)
‡ The ConnectX-6 HDR adapter is supported only in the configurations with two processors, and it requires the HDR/200GbE 2x PCIe Aux Kit.
§ The SiNEAD I350-C4 adapter is only available for customers in Mainland China (PRC). Not supported installed with Intel I350 adapters.
¤ When the Xilinx Alveo U50 is installed in slot 5, slot 6 should be left empty; When the Xilinx Alveo U50 is installed in slot 1, slot 2 should be left empty and slot 3 can only be occupied by adapters of less than 25W power consumption.

For more information, see the list of Product Guides in the Ethernet Adapters category:
http://lenovopress.com/servers/options/ethernet#rt=product-guide

Configuration notes:

  • ML2 network adapters are supported in the ML2 x8 slot 3 supplied by the x8/x8/x8ML2 Riser Card 1 (7XH7A02680).
  • PCIe full-height network adapters are supported in the full-height PCIe x8 and x16 slots supplied by the riser cards 1 and 2.
  • PCIe x16 Low Profile network adapters are supported in the full-height PCIe x16 slots supplied by the riser cards 1 and 2.
  • PCIe x8 or x4 Low Profile network adapters are supported in the low profile PCIe x8 slot 4 on the system board and full-height PCIe x8 and x16 slots supplied by the riser cards 1 and 2.
  • The Mellanox HDR and HDR100 InfiniBand QSFP56 adapters are supported only in the configurations with up to 16x 2.5-inch or 8x 3.5-inch drive bays and only with an ambient temperature of up to 35 °C (95 °F). Not supported in 12x 3.5-inch or 24x 2.5-inch configurations.
  • In the configurations with two double-wide GPU adapters and a PCIe x16 adapter, the following adapters are supported in the PCIe 3.0 x16 slot 3 supplied by the PCIe x16/x8/x16 Riser Card (4XH7A09902):
    • Mellanox ConnectX-4 1x100GbE/EDR IB QSFP28 VPI Adapter (00KH924)
    • Mellanox ConnectX-4 2x100GbE/EDR IB QSFP28 VPI Adapter (00MM960)
    • Mellanox ConnectX-5 Ex 25/40GbE 2-port Low-Latency Adapter (4XC7A08229)
    • Intel OPA 100 Series Single-port PCIe 3.0 x16 HFA (00WE027)
  • Supported transceivers or DAC cables should be purchased for the SFP+, SFP28, QSFP+, and QSFP28 adapters, and UTP Category 6 or Category 5e cables should be purchased for the 10 GbE (Cat6) or 1 GbE (Cat5e or Cat6) RJ-45 adapters. The maximum number of transceivers or cables that are supported per adapter equals the quantity of the adapter ports, and all adapter ports must have the same type of the transceiver or cable selected. See the product guide for the adapter for the list of supported transceivers and cables.

  • E810 Ethernet and X350 RAID/HBAs: The use of both an Intel E810 network adapter and an X350 HBA/RAID adapter (9350, 5350 and 4350) is supported, however E810 firmware CVL4.3 or later is required. For details, see Support Tip HT513226.

SAS adapters for external storage

The following table lists SAS RAID controllers and HBAs for external storage attachments that are supported by the SR650 server.

Table 55. SAS RAID adapters and HBAs for external storage
Part number Feature code Description Maximum quantity* I/O slots supported
12 Gbps SAS RAID adapters
7Y37A01087 AUNQ ThinkSystem RAID 930-8e 4GB Flash PCIe 12Gb Adapter 4 / 4 4, 2, 3, 1, 5
4Y37A78836 BNWJ ThinkSystem RAID 940-8e 4GB Flash PCIe Gen4 12Gb Adapter 4 / 4 4, 2, 3, 1, 5
12 Gbps SAS HBAs
7Y37A01090 AUNR ThinkSystem 430-8e SAS/SATA 12Gb HBA 4 / 5 4, 2, 3, 1, 5
7Y37A01091 AUNN ThinkSystem 430-16e SAS/SATA 12Gb HBA 4 / 5 4, 2, 3, 1, 5
4Y37A78837 BNWK ThinkSystem 440-8e SAS/SATA PCIe Gen4 12Gb HBA 4 / 5 4, 2, 3, 1, 5
4Y37A09724 B8P7 ThinkSystem 440-16e SAS/SATA PCIe Gen4 12Gb HBA 4 / 5 4, 2, 3, 1, 5

* The maximum quantity shown is with one processor / two processors.

For a comparison of the functions of the supported storage adapters, see the ThinkSystem RAID Adapter and HBA Reference:
https://lenovopress.com/lp1288#sr650-support=SR650&internal-or-external-ports=External

Configuration notes:

  • Low profile SAS RAID controllers and HBAs for external storage are supported in the low profile PCIe x8 slot 4 on the system board and full-high PCIe x8 and x16 slots supplied by the riser cards 1 and 2 (except slot 6).
  • In the configurations without GPU installed, the total quantity of the RAID 730-8i 2GB, RAID 930-8i, RAID 930-16i, RAID 930-24i, and RAID 940-8e, and RAID 930-8e controllers in a supported combination in the server must not exceed 4 (up to 4 supercapacitors can be mounted in the server).
  • In the configurations with GPU installed, the total quantity of the RAID 730-8i 2GB, RAID 930-8i, RAID 930-16i, RAID 930-24i, RAID 940-8e, and RAID 930-8e controllers in a supported combination in the server must not exceed 3 (up to 3 supercapacitors can be mounted in the server).

Mixing storage adapter families: The following HBA/RAID adapter combinations are supported:

  • X30 external adapters with other X30 adapters (internal or external)
  • X40 external adapters with other X40 adapters (internal or external)
  • X40 external adapters with X350 internal adapters

The following HBA/RAID adapter combinations are not supported:

  • X30 adapters (internal or external) with X40 adapters (internal or external)
  • X30 adapters (internal or external) with X350 internal adapters

For more information, see the list of Product Guides in the following categories:

Fibre Channel host bus adapters

The following table lists Fibre Channel HBAs supported by the SR650 server.

Table 56. Fibre Channel HBAs
Part
number
Feature
code
Description Maximum
quantity*
I/O slots
supported
64 Gb Fibre Channel - PCIe
4XC7A77485 BLC1 ThinkSystem Emulex LPe36002 64Gb 2-port PCIe Fibre Channel Adapter 4 / 6 4, 2, 6, 3, 5, 1
32 Gb Fibre Channel - PCIe
4XC7A76525 BJ3H ThinkSystem Emulex LPe35002 32Gb 2-port PCIe Fibre Channel Adapter V2 4 / 6 4, 2, 6, 3, 5, 1
4XC7A76498 BJ3G ThinkSystem Emulex LPe35000 32Gb 1-port PCIe Fibre Channel Adapter v2 4 / 6 4, 2, 6, 3, 5, 1
4XC7A08250 B5SX Emulex LPe35000 32Gb 1-port PCIe Fibre Channel Adapter 4 / 6 4, 2, 6, 3, 5, 1
4XC7A08251 B5SY Emulex LPe35002 32Gb 2-port PCIe Fibre Channel Adapter 4 / 6 4, 2, 6, 3, 5, 1
7ZT7A00517 AUNT Emulex LPe32000-M2-L PCIe 32Gb 1-Port SFP+ FC HBA 4 / 6 4, 2, 6, 3, 5, 1
7ZT7A00519 AUNV Emulex LPe32002-M2-L PCIe 32Gb 2-Port SFP+ FC HBA 4 / 6 4, 2, 6, 3, 5, 1
7ZT7A00516 AUNS QLogic QLE2740 PCIe 32Gb 1-Port SFP+ FC HBA 4 / 6 4, 2, 6, 3, 5, 1
7ZT7A00518 AUNU QLogic QLE2742 PCIe 32Gb 2-Port SFP+ FC HBA 4 / 6 4, 2, 6, 3, 5, 1
16 Gb Fibre Channel - PCIe
01CV830 ATZU Emulex 16Gb Gen6 FC Single-port HBA 4 / 6 4, 2, 6, 3, 5, 1
01CV840 ATZV Emulex 16Gb Gen6 FC Dual-port HBA 4 / 6 4, 2, 6, 3, 5, 1
01CV750 ATZB QLogic 16Gb Enhanced Gen5 FC Single-port HBA 4 / 6 4, 2, 6, 3, 5, 1
01CV760 ATZC QLogic 16Gb Enhanced Gen5 FC Dual-port HBA 4 / 6 4, 2, 6, 3, 5, 1
8 Gb Fibre Channel - PCIe (available only in PRC and AP)
4XC7A08220 B0WZ Emulex LPe12000-M8-L PCIe 8Gb 1-Port SFP+ FC HBA 4 / 6 4, 2, 6, 3, 5, 1
4XC7A08221 B0X0 Emulex LPe12002-M8-L PCIe 8Gb 2-Port SFP+ FC HBA 4 / 6 4, 2, 6, 3, 5, 1

* The maximum quantity shown is with one processor / two processors.

Configuration note: FC HBAs are supported in the low profile PCIe x8 slot 4 on the system board and full-high PCIe x8 and x16 slots supplied by the riser cards 1 and 2.

For more information, see the list of Product Guides in the Host bus adapters category:
http://lenovopress.com/servers/options/hba#rt=product-guide

Flash storage adapters

The SR650 server supports the flash storage adapters listed in the following table.

Table 57. Flash storage adapters
Part
number
Feature
code
Description Maximum
quantity*
I/O slots
supported
Performance Flash Adapters - PX04PMC
7XB7A05925 AWG8 PX04PMC 1.6TB Performance NVMe PCIe 3.0 x4 Flash Adapter 4 / 6 4, 2, 6, 3, 5, 1
7XB7A05924 AWG9 PX04PMC 3.2TB Performance NVMe PCIe 3.0 x4 Flash Adapter 4 / 6 4, 2, 6, 3, 5, 1
Mainstream Flash Adapters - PM1735
4XB7A14075 B8JH ThinkSystem HHHL PM1735 1.6TB Mainstream NVMe PCIe4.0 x4 Flash Adapter 4 / 6 4, 2, 6, 3, 5, 1
4XB7A14076 B8HW ThinkSystem HHHL PM1735 3.2TB Mainstream NVMe PCIe4.0 x4 Flash Adapter 4 / 6 4, 2, 6, 3, 5, 1
4XB7A14077 B96M ThinkSystem HHHL PM1735 6.4TB Mainstream NVMe PCIe4.0 x8 Flash Adapter 4 / 6 4, 2, 6, 3, 5, 1
Mainstream Flash Adapters - CM5-V
4XB7A38234 BCGJ CM5-V 1.6TB Mainstream NVMe PCIe 3.0 x4 Flash Adapter 4 / 6 4, 2, 6, 3, 5, 1
4XB7A38237 BCGK CM5-V 3.2TB Mainstream NVMe PCIe 3.0 x4 Flash Adapter 4 / 6 4, 2, 6, 3, 5, 1
4XB7A38240 BCGL CM5-V 6.4TB Mainstream NVMe PCIe 3.0 x4 Flash Adapter 4 / 6 4, 2, 6, 3, 5, 1
Mainstream Flash Adapters - CM5-V
4XB7A08520 B32L CM5-V 1.6TB Mainstream NVMe PCIe 3.0 x4 Flash Adapter 4 / 6 4, 2, 6, 3, 5, 1
4XB7A08521 B32M CM5-V 3.2TB Mainstream NVMe PCIe 3.0 x4 Flash Adapter 4 / 6 4, 2, 6, 3, 5, 1
4XB7A08522 B32N CM5-V 6.4TB Mainstream NVMe PCIe 3.0 x4 Flash Adapter 4 / 6 4, 2, 6, 3, 5, 1
Mainstream Flash Adapters - P4600
7SD7A05769 B11X Intel P4600 2.0TB Mainstream NVMe PCIe 3.0 x4 Flash Adapter 4 / 6 4, 2, 6, 3, 5, 1
7SD7A05768 B11Y Intel P4600 4.0TB Mainstream NVMe PCIe 3.0 x4 Flash Adapter 4 / 6 4, 2, 6, 3, 5, 1
Mainstream Flash Adapters - PX04PMC
7N47A00097 AUUP PX04PMC 1.92TB Mainstream NVMe PCIe 3.0 x4 Flash Adapter 4 / 6 4, 2, 6, 3, 5, 1
7N47A00098 AUVY PX04PMC 3.84TB Mainstream NVMe PCIe 3.0 x4 Flash Adapter 4 / 6 4, 2, 6, 3, 5, 1
Entry Flash Adapters - P4500
7SD7A05776 B11Z Intel P4500 4.0TB Entry NVMe PCIe 3.0 x4 Flash Adapter 4 / 6 4, 2, 6, 3, 5, 1
7SD7A05775 B120 Intel P4500 8.0TB Entry NVMe PCIe 3.0 x4 Flash Adapter 4 / 6 4, 2, 6, 3, 5, 1

* The maximum quantity shown is with one processor / two processors.

Configuration notes:

  • Flash storage adapters are supported in the low profile PCIe x8 slot on the system board and full-high PCIe x8 and x16 slots supplied by the riser cards 1 and 2.
  • Flash storage adapters are supported only in the environments with an ambient temperature of up to 35 °C (95 °F).
  • Flash storage adapters are supported only with processors of up to 165 W TDP.
  • Flash storage adapters are not supported with persistent memory

For more information, see the list of Product Guides in the Flash storage adapters category:
http://lenovopress.com/servers/options/ssdadapter#rt=product-guide

GPU adapters

The SR650 server supports graphics processing units (GPUs) listed in the following table.

Table 58. GPU adapters
Part
number
Feature
code
Description Maximum
quantity*
I/O slots
supported
Single-wide PCIe x16 GPU adapters
4X67A71311 BFTZ ThinkSystem NVIDIA A10 24GB PCIe Gen4 Passive GPU 1 / 4 1, 5, 6, 2
CTO only BQZS ThinkSystem NVIDIA A10 24GB PCIe Gen4 Passive GPU w/o CEC 1 / 4 1, 5, 6, 2
4X67A81547 BP05 ThinkSystem NVIDIA A2 16GB PCIe Gen4 Passive GPU 3 / 5 1, 2, 3, 5, 6
CTO only BQZT ThinkSystem NVIDIA A2 16GB PCIe Gen4 Passive GPU w/o CEC 3 / 5 1, 2, 3, 5, 6
4X67A14926 B4YB ThinkSystem NVIDIA Tesla T4 16GB PCIe Passive GPU 3 / 5§ 1, 2, 3, 5, 6
4X67A14934 B6CG ThinkSystem NVIDIA Quadro RTX 4000 8GB PCIe Active GPU 1 / 3 1, 5, 6
4X67A11584 B31D ThinkSystem NVIDIA Quadro P620 2GB PCIe Active GPU 1 / 3 1, 5, 6
4X67A11524 B32D ThinkSystem NVIDIA Tesla V100 FHHL 16GB PCIe GPU 1 / 3 1, 5, 6
7C57A02892 B227 ThinkSystem NVIDIA Tesla P4 8GB PCIe Passive GPU 1 / 5§ 1, 5, 6, 2, 3
4V17A10255 B225 ThinkSystem NVIDIA Quadro P4000 8GB PCIe Active GPU 1 / 3 1, 5, 6
7C57A02894 B226 ThinkSystem NVIDIA Quadro P600 2GB PCIe Active GPU 1 / 3 1, 5, 6
Double-wide PCIe x16 GPU adapters
4X67A76715 BLK1 ThinkSystem NVIDIA A100 80GB PCIe Gen4 Passive GPU 1 / 2 1, 5
CTO only BQZP ThinkSystem NVIDIA A100 80GB PCIe Gen4 Passive GPU w/o CEC 1 / 2 1, 5
4X67A86324 BUGD ThinkSystem NVIDIA A800 80GB PCIe Gen4 Passive GPU 1 / 2 1, 5
4X67A13135† BEL5 ThinkSystem NVIDIA A100 40GB PCIe Gen4 Passive GPU 1 / 2 1, 5
4X67A76581 BJHG ThinkSystem NVIDIA A30 24GB PCIe Gen4 Passive GPU 1 / 2 1, 5
CTO only BQZR ThinkSystem NVIDIA A30 24GB PCIe Gen4 Passive GPU w/o CEC 1 / 2 1, 5
4X67A76727 BNFE ThinkSystem NVIDIA A16 64GB Gen4 PCIe Passive GPU 1 / 2 1, 5
CTO only BQZU ThinkSystem NVIDIA A16 64GB Gen4 PCIe Passive GPU w/o CEC 1 / 2 1, 5
4X67A13124 BB2E ThinkSystem NVIDIA Tesla V100S 32GB PCIe Passive GPU 1 / 2 1, 5
4C57A09498 B1JY ThinkSystem NVIDIA Tesla V100 16GB PCIe Passive GPU 1 / 2 1, 5
4X67A12088 B34S ThinkSystem NVIDIA Tesla V100 32GB PCIe Passive GPU 1 / 2 1, 5
4X67A71310 BFT0 ThinkSystem NVIDIA Quadro RTX A6000 48GB PCIe Active GPU 1 / 2 1, 5
4X67A65441‡ BCGR ThinkSystem NVIDIA Quadro RTX 8000 48GB PCIe Passive GPU 1 / 2 1, 5
4X67A13125‡ BB2D ThinkSystem NVIDIA Quadro RTX 6000 24GB PCIe Passive GPU 1 / 2 1, 5
4X67A17267 B6CH ThinkSystem NVIDIA Quadro RTX 5000 16GB PCIe Active GPU 1 / 2 1, 5
7C57A02897 B228 ThinkSystem AMD Radeon Instinct MI25 16GB PCIe Passive GPU 1 / 2 1, 5
4C57A09497 B32P ThinkSystem AMD Radeon Pro V340 32GB PCIe Passive GPU 1 / 2 1, 5
7C57A02895 B2V5 ThinkSystem NVIDIA Quadro P6000 24GB GPU, PCIe (active) 1 / 2 1, 5
7C57A02891 B15V ThinkSystem NVIDIA Tesla M10 32GB PCIe Passive GPU 1 / 2 1, 5
00KG655 B13J NVIDIA Tesla M60 GPU, PCIe (Passive) 1 / 2 1, 5
7C57A02888 B15U ThinkSystem NVIDIA Tesla P40 24GB PCIe Passive GPU 1 / 2 1, 5
7X67A00068 B13H NVIDIA Tesla P100 16GB PCIe Passive GPU 1 / 2 1, 5

* The maximum quantity shown is with one processor / two processors.
† The NVIDIA A100 requires UEFI firmware 2.80 or later, and XClarity Controller firmware 5.40 or higher. 
‡ The RTX 6000 and RTX 8000 GPUs are only available via Special Bid.
§ SR650 with 1st Gen Xeon processors supports up to 4x NVIDIA T4 GPUs or 2x NVIDIA P4 GPUs

Configuration notes:

  • Some NVIDIA A Series GPUs are available as two feature codes, one with a CEC chip and one without a CEC chip (ones without the CEC chip have "w/o CEC" in the name). The CEC is a secondary Hardware Root of Trust (RoT) module that provides an additional layer of security, which can be used by customers who have high regulatory requirements or high security standards. NVIDIA uses a multi-layered security model and hence the protection offered by the primary Root of Trust embedded in the GPU is expected to be sufficient for most customers. The CEC defeatured products still offer Secure Boot, Secure Firmware Update, Firmware Rollback Protection, and In-Band Firmware Update Disable. Specifically, without the CEC chip, the GPU does not support Key Revocation or Firmware Attestation. CEC and non-CEC GPUs of the same type of GPU can be mixed in field upgrades.
  • All GPU adapters in the server must be of the same model; mixing different GPU adapter models is not supported.
  • NVIDIA A2 and T4 and P4 are PCIe x16 adapters, however in the SR650, the GPUs are also supported in PCIe riser x8 slots with x16 physical connectors. Note, however, that a x8 host connection may result in a performance decrease of approximately 5%.
  • For field upgrades to add an NVIDIA A-Series GPU (A100, A6000, A30, A16, A10, A2), the use of Riser 2 V2 riser kit (4TA7A70026) is required when the GPU is to be installed in slot 5. The older Riser 2 kit (7XH7A02679, now withdrawn) is not supported with the A100. For CTO orders, feature code BF9Y will be used for the correct Riser 2 bracket.
  • The T4 GPU adapters are supported only in the specific I/O slots, as follows:
    • 1x T4 GPU adapter (one or two processors):
      • PCIe 3.0 x16 Slot 1 on the x16/x8 Riser Card 1 (7XH7A02678); or
      • PCIe 3.0 x8 Slot 1 on the x8/x8/x8 Riser Card 1 (7XH7A02677).
    • 2x T4 GPU adapters:
      • One processor: PCIe 3.0 x8 Slots 1 and 2 on the x8/x8/x8 Riser Card 1 (7XH7A02677).
      • Two processors: 
        • PCIe 3.0 x16 or x8 Slot 1 on one of the following riser cards:
          • PCIe 3.0 x16 Slot 1 on the x16/x8 Riser Card 1 (7XH7A02678); or
          • PCIe 3.0 x8 Slot 1 on the x8/x8/x8 Riser Card 1 (7XH7A02677).
        • PCIe 3.0 x16 Slot 5 on the x16/x16 Riser Card 2 (4TA7A70026 or 7XH7A02679).
      • Note: Slot 6 must remain unoccupied in the configurations with two T4 GPU adapters.
    • 3x T4 GPU adapters:
      • One processor: PCIe 3.0 x8 Slots 1, 2, and 3 on the x8/x8/x8 Riser Card 1 (7XH7A02677).
      • Two processors: 
        • PCIe 3.0 x16 or x8 Slot 1 on one of the following riser cards:
          • PCIe 3.0 x16 Slot 1 on the x16/x8 Riser Card 1 (7XH7A02678); or
          • PCIe 3.0 x8 Slot 1 on the x8/x8/x8 Riser Card 1 (7XH7A02677).
        • PCIe 3.0 x16 Slots 5 and 6 on the x16/x16 Riser Card 2 (4TA7A70026 or 7XH7A02679).
    • 4x T4 GPU adapters (require two processors):
      • PCIe 3.0 x8 or x16 Slot 1 and PCIe 3.0 x8 Slot 2 on one of the following riser cards:
        • x8/x8/x8 Riser Card 1 (7XH7A02677); or
        • x16/x8/x16 Riser Card 1 (4XH7A09902).
      • PCIe 3.0 x16 Slots 5 and 6 on the x16/x16 Riser Card 2 (4TA7A70026 or 7XH7A02679).
    • 5x T4 GPU adapters (require two processors) (2nd Gen Xeon processors only):
      • PCIe 3.0 x8 or x16 Slots 1 and 3, and PCIe 3.0 x8 Slot 2 on one of the following riser cards:
        • x8/x8/x8 Riser Card 1 (7XH7A02677); or
        • x16/x8/x16 Riser Card 1 (4XH7A09902).
      • PCIe 3.0 x16 Slots 5 and 6 on the x16/x16 Riser Card 2 (4TA7A70026 or 7XH7A02679).
  • The P4 GPU adapters are supported only in the specific I/O slots, as follows:
    • 1x P4 GPU adapter: PCIe 3.0 x16 Slot 1 on the x16/x8 Riser Card 1 (7XH7A02678).
    • 2x P4 GPU adapters:
      • PCIe 3.0 x16 Slot 1 on the x16/x8 Riser Card 1 (7XH7A02678).
      • PCIe 3.0 x16 Slot 5 on the x16/x16 Riser Card 2 (4TA7A70026 or 7XH7A02679).
        Note: Slot 6 must remain unoccupied in the configurations with P4 GPU adapters.
    • 3x P4 GPU adapters:
      • PCIe 3.0 x16 Slot 1 on the x16/x8 Riser Card 1 (7XH7A02678).
      • PCIe 3.0 x16 Slots 5 and 6 on the x16/x16 Riser Card 2 (4TA7A70026 or 7XH7A02679).
    • 4x P4 GPU adapters:
      • PCIe 3.0 x8 or x16 Slot 1 and PCIe 3.0 x8 Slot 2 on one of the following riser cards:
        • x8/x8/x8 Riser Card 1 (7XH7A02677); or
        • x8/x8/ML2 Riser Card 1 (7XH7A02680); or
        • x16/x8/x16 Riser Card 1 (4XH7A09902).
      • PCIe 3.0 x16 Slots 5 and 6 on the x16/x16 Riser Card 2 (4TA7A70026 or 7XH7A02679).
    • 5x P4 GPU adapters:
      • PCIe 3.0 x8 or x16 Slots 1 and 3, and PCIe 3.0 x8 Slot 2 on one of the following riser cards:
        • x8/x8/x8 Riser Card 1 (7XH7A02677); or
        • x16/x8/x16 Riser Card 1 (4XH7A09902).
      • PCIe 3.0 x16 Slots 5 and 6 on the x16/x16 Riser Card 2 (4TA7A70026 or 7XH7A02679).
  • The GPU adapters are supported with the following drive bay configurations:
    • Processors of up to 150 W TDP:
      • 8x or 16x 2.5-inch SAS/SATA & AnyBay drive bays (support for up to 4x or 8x NVMe SSDs).
      • 8x 3.5-inch SAS/SATA drive bays.
    • Processors of more than 150 W and up to 205 W TDP with up to four T4 GPU adapters, or processors of more than 150 W and up to 165 W TDP:
      • 8x 2.5-inch SAS/SATA drive bays (no support for NVMe SSDs) in the environments with the ambient temperature of up to 30 °C (86 °F).
    • Note: The P4, P600, P620, P4000, P6000, V100 FHHL, and V340 GPU adapters are supported only with the processors of up to 150 W TDP.
  • If a double-wide GPU adapter is installed in the PCIe slot 5, the PCIe slot 6 cannot be used.
  • The P600 and P620 GPU adapters do not require any thermal kits. The GPU adapters other than P600 or P620 may require one of the optional GPU Thermal Kits (see Cooling for details).
  • GPU adapters are supported with the 1100 W or 1600 W power supplies. Some configurations also support a GPU adapter with 750 W power supplies installed.
  • GPU adapters (except V100 FHHL and T4 GPU adapters) are supported only in the ASHRAE A2 environments (up to 35 °C [95 °F]); the V100 FHHL and T4 GPU adapters are supported only in the environments with the ambient temperature of up to 30 °C (86 °F).
  • Configurations with two double-wide GPU adapters and a PCIe x16 adapter are supported only in the environments with the ambient temperature of up to 30 °C (86 °F), and with SAS/SATA drive bays only (no AnyBay or U.2 NVMe support).
  • If the GPU adapters are installed, the server performance might be impacted in case of a system fan failure.
  • The GPU adapters are not supported with the T-suffix processors.
  • The GPU adapters are not supported with the persistent memory modules.
  • The GPU adapters are not supported with the PCIe flash storage adapters.
  • The GPU adapters are not supported with the Rear HDD Kit.
  • The maximum server memory that can be installed with the NVIDIA Tesla M10 or M60 GPU is 1 TB.

Auxiliary power cables

For CTO orders, the necessary GPU auxiliary power cable is derived by the configurator.

For field upgrades, some Lenovo GPU adapter options come with the necessary power cables for internal cabling. For all others, you will need to order the cable separately using the SR650 GPU cable kit. Details in the following table.

Table 59. SR650 GPU cable kit option
Part number Description
4XH7A08794

ThinkSystem SR650 GPU Cable Kit

  • SBB7A00293 - 300mm PCIe 6pin (2x3) + PCIe 8pin (2x4)
    • For use with NVIDIA M10, RTX 5000, P6000 and AMD MI25
    • Also included in Lenovo GPU option part numbers
  • SBB7A00299 - 300mm 8pin (2x4) cable
    • For use with NVIDIA V100S, V100, P40, RTX 8000, A100, RTX 6000, RTX A6000
    • Also included in Lenovo GPU option part numbers for V100S, V100, P40, and RTX 8000
  • SBB7A05971 - 300mm 2x 8pin (2x4) cable
    • For use with NVIDIA V100 FHHL, RTX 4000, A10
  • SBB7A05946 - 300mm 2x PCIe 6pin (2x3)
    • For use with NVIDIA P4000

Cooling

The SR650 server supports up to six hot-swap single-rotor system fans that provide N+1 cooling redundancy: Models with one processor ship with five system fans, and models with two processors ship with six system fans.

In the case of a system fan failure, performance might be impacted with any of the following server configurations:

  • Gen 2 processors with 200 W or 205 W TDP, or Gold 6230N, 6240Y, 6244, or 6250 are installed.
  • Gen 1 processors Intel Xeon 6137, 6144, 6146, 6154, 8168, 8180, and 8180M are installed.
  • Persistent memory modules are installed.
  • GPU adapters are installed.
  • 16/20/24x 2.5" U.2 NVMe PCIe drive bays at the ambient temperature of more than 30 °C (86 °F).

The following table shows additional cooling options.

Table 60. Cooling options
Part number Feature code Description Maximum quantity
4F17A12349 AUSG ThinkSystem SR650 Fan Option Kit (for 2nd Gen processors only; 1st Gen processor options include a fan) 1
4XH7A08791 B31F ThinkSystem SR650/SR550/SR590 M.2 Thermal Kit 1
7XH7A05897 None ThinkSystem SR650 GPU Thermal Kit 1
7XH7A05899 AURU ThinkSystem SR650 2nd GPU Upgrade Kit 1
7XH7A05898 None ThinkSystem SR650 GPU 1U Heatsink Option Kit 1
4XH7A08776 B26L ThinkSystem SR650 P4 GPU Additional Air Duct Upgrade Kit 2
4XH7A08792 B37F ThinkSystem SR650 V100 FHHL Air Duct Companion Kit 2

Configuration notes:

  • The installation of a 2nd processor requires an extra cooling fan be installed. For CTO orders, fans are derived by the configurator. For field upgrades, 1st Gen processor option part numbers include this fan however 2nd Gen processor options do not included the fan and it must be ordered separately using SR650 Fan Option Kit (4F17A12349).
  • The ThinkSystem SR650/SR550/SR590 M.2 Thermal Kit (4XH7A08791) is required when at least one M.2 5100, 5300, or 5400 SSD is installed in the server; however, the SSD Thermal Kit is not required in the server configurations with the GPU Thermal Kit (7XH7A05897) (factory-installed or field upgrade). If required, the M.2 SSD Thermal Kit is derived by the configurator for initial server configurations, or it should be purchased for M.2 5100, 5300 or 5400 SSDs for field upgrades.
  • The P600 and P620 GPU adapters do not require any thermal kits.
  • The full-length PCIe adapters and GPU adapters other than P600 or P620 require one of the following thermal kits depending on the configuration:
    • The GPU Thermal Kit (7XH7A05897) is required when adding GPUs or full-length PCIe adapters to the SR650 server models without factory-installed GPUs or factory-enabled full-length support. The kit provides support for up to three GPUs or full-length adapters in the PCIe x16 slots 1, 5, and 6, and it contains an air duct, two low-profile heatsinks, and two full-length card holders.
    • The 2nd GPU Upgrade Kit (7XH7A05899) is required when adding more GPUs or full-length adapters to the SR650 server models with one riser card and the factory-enabled full-length support or factory-installed GPUs. The kit provides support for the additional GPUs or full-length adapters, and it contains a full-length card holder (the second riser card is not included in the kit).
    • The GPU 1U Heatsink Option Kit (7XH7A05898) is required when adding the second processor to the SR650 server models with one processor and the factory-enabled full-length support or factory-installed GPUs. The kit contains a low-profile heatsink for the second processor option.
  • The P4 GPU adapters might require the following quantities of the P4 GPU Additional Air Duct Upgrade Kit (4XH7A08776) in addition to one of the thermal kits described above:
    • 1x or 3x P4 GPU adapters: 1x Additional Air Duct Upgrade Kit.
    • 2x P4 GPU adapters: 2x Additional Air Duct Upgrade Kits.
    • 4x or 5x P4 GPU adapters: No Additional Air Duct Upgrade Kits are required.
  • The V100 FHHL GPU adapters require the following quantities of the V100 FHHL Air Duct Companion Kit (4XH7A08792) in addition to one of the thermal kits described above:
    • 1x V100 FHHL GPU adapter: 1x Air Duct Companion Kit.
    • 2x or 3x V100 FHHL GPU adapters: 2x Air Duct Companion Kits.

Power supplies

The SR650 server supports up to two redundant power supplies and is capable of N+N redundancy depending on the configuration. A second power supply can be added to the models that come with one power supply.

The following table lists the power supply options.

Table 61. Power supplies
Part number Feature code Description Maximum quantity
7N67A00882 AVWC ThinkSystem 550W (230V/115V) Platinum Hot-Swap Power Supply 2
7N67A00883 AVWD ThinkSystem 750W (230/115V) Platinum Hot-Swap Power Supply 2
7N67A00884 AVWE ThinkSystem 750W (230V) Titanium Hot-Swap Power Supply 2
4P57A82020 BR1Y ThinkSystem V1 750W (230Vac) Titanium Hot Swap Power Supply 2
7N67A00885 AVWF ThinkSystem 1100W (230V/115V) Platinum Hot-Swap Power Supply 2
7N67A00886 AVWG ThinkSystem 1600W (230V) Platinum Hot-Swap Power Supply 2
4P57A15363‡ B4Z5‡ ThinkSystem 1100W -48V DC Power Supply 2

‡ Special bid only

Power supply options do not include a line cord. For server configurations, the inclusion of a power cord is model dependent. Configure-to-order models can be configured without power cords if desired.

Configuration notes:

  • Minimum of 1 and maximum of 2 power supplies per system.
  • If 2 are installed, power supplies must be identical.
  • AC power supplies support AC (Worldwide) and HVDC (PRC only) power sources
  • AC power supplies have a C14 connector. The -48V DC power supply has a Positronic PLB3W3M1000/AA connector.

Important: The Standalone Solution Configuration Tool (SSCT) and Lenovo Data Center Solution Configurator (DCSC) power supply selection rules allow a subset of possible configurations due to power restrictions. Configurations that cannot be built in SSCT or DCSC due to power restrictions may still be supported. To verify support and ensure that the right power supply is chosen for optimal performance, you should always validate your server configuration using the latest version of the Lenovo Capacity Planner:
http://datacentersupport.lenovo.com/us/en/solutions/lnvo-lcp

Power cords

Line cords and rack power cables with C13 connectors can be ordered as listed in the following table.

110V customers: If you plan to use the 1100W power supply with a 110V power source, select a power cable that is rated above 10A. Power cables that are rated at 10A or below are not supported with 110V power.

Table 62. Power cords
Part number Feature code Description
Rack cables - C13 to C14
SL67B08593 BPHZ 0.5m, 10A/100-250V, C13 to C14 Jumper Cord
00Y3043 A4VP 1.0m, 10A/100-250V, C13 to C14 Jumper Cord
4L67A08367 B0N5 1.0m, 13A/100-250V, C13 to C14 Jumper Cord
39Y7937 6201 1.5m, 10A/100-250V, C13 to C14 Jumper Cord
4L67A08368 B0N6 1.5m, 13A/100-250V, C13 to C14 Jumper Cord
4L67A08365 B0N4 2.0m, 10A/100-250V, C13 to IEC 320-C14 Rack Power Cable
4L67A08369 6570 2.0m, 13A/100-250V, C13 to C14 Jumper Cord
4L67A08366 6311 2.8m, 10A/100-250V, C13 to C14 Jumper Cord
4L67A08370 6400 2.8m, 13A/100-250V, C13 to C14 Jumper Cord
39Y7932 6263 4.3m, 10A/100-250V, C13 to IEC 320-C14 Rack Power Cable
4L67A08371 6583 4.3m, 13A/100-250V, C13 to C14 Rack Power Cable
Rack cables - C13 to C14 (Y-cable)
00Y3046 A4VQ 1.345m, 2X C13 to C14 Jumper Cord, Rack Power Cable
00Y3047 A4VR 2.054m, 2X C13 to C14 Jumper Cord, Rack Power Cable
Rack cables - C13 to C20
39Y7938 6204 2.8m, 10A/100-250V, C13 to IEC 320-C20 Rack Power Cable
Rack cables - C13 to C20 (Y-cable)
47C2491 A3SW 1.2m, 16A/100-250V, 2 Short C13s to Short C20 Rack Power Cable
47C2492 A3SX 2.5m, 16A/100-250V, 2 Long C13s to Short C20 Rack Power Cable
47C2493 A3SY 2.8m, 16A/100-250V, 2 Short C13s to Long C20 Rack Power Cable
47C2494 A3SZ 4.1m, 16A/100-250V, 2 Long C13s to Long C20 Rack Power Cable
Line cords
39Y7930 6222 2.8m, 10A/250V, C13 to IRAM 2073 (Argentina) Line Cord
81Y2384 6492 4.3m 10A/220V, C13 to IRAM 2073 (Argentina) Line Cord
39Y7924 6211 2.8m, 10A/250V, C13 to AS/NZ 3112 (Australia/NZ) Line Cord
81Y2383 6574 4.3m, 10A/230V, C13 to AS/NZS 3112 (Aus/NZ) Line Cord
69Y1988 6532 2.8m, 10A/250V, C13 to NBR 14136 (Brazil) Line Cord
81Y2387 6404 4.3m, 10A/250V, C13 - 2P+Gnd (Brazil) Line Cord
39Y7928 6210 2.8m, 220-240V, C13 to GB 2099.1 (China) Line Cord
81Y2378 6580 4.3m, 10A/220V, C13 to GB 2099.1 (China) Line Cord
39Y7918 6213 2.8m, 10A/250V, C13 to DK2-5a (Denmark) Line Cord
81Y2382 6575 4.3m, 10A/230V, C13 to DK2-5a (Denmark) Line Cord
39Y7917 6212 2.8m, 10A/230V, C13 to CEE7-VII (Europe) Line Cord
81Y2376 6572 4.3m, 10A/230V, C13 to CEE7-VII (Europe) Line Cord
39Y7927 6269 2.8m, 10A/250V, C13(2P+Gnd) (India) Line Cord
81Y2386 6567 4.3m, 10A/240V, C13 to IS 6538 (India) Line Cord
39Y7920 6218 2.8m, 10A/250V, C13 to SI 32 (Israel) Line Cord
81Y2381 6579 4.3m, 10A/230V, C13 to SI 32 (Israel) Line Cord
39Y7921 6217 2.8m, 220-240V, C13 to CEI 23-16 (Italy/Chile) Line Cord
81Y2380 6493 4.3m, 10A/230V, C13 to CEI 23-16 (Italy/Chile) Line Cord
46M2593 A1RE 2.8m, 12A/125V, C13 to JIS C-8303 (Japan) Line Cord
4L67A08362 6495 4.3m, 12A/200V, C13 to JIS C-8303 (Japan) Line Cord
39Y7926 6335 4.3m, 12A/100V, C13 to JIS C-8303 (Japan) Line Cord
39Y7922 6214 2.8m, 10A/250V, C13 to SABS 164 (S Africa) Line Cord
81Y2379 6576 4.3m, 10A/230V, C13 to SABS 164 (South Africa) Line Cord
39Y7925 6219 2.8m, 220-240V, C13 to KETI (S Korea) Line Cord
81Y2385 6494 4.3m, 12A/220V, C13 to KSC 8305 (S. Korea) Line Cord
39Y7919 6216 2.8m, 10A/250V, C13 to SEV 1011-S24507 (Swiss) Line Cord
81Y2390 6578 4.3m, 10A/230V, C13 to SEV 1011-S24507 (Sws) Line Cord
23R7158 6386 2.8m, 10A/125V, C13 to CNS 10917-3 (Taiwan) Line Cord
81Y2375 6317 2.8m, 10A/240V, C13 to CNS 10917-3 (Taiwan) Line Cord
81Y2374 6402 2.8m, 13A/125V, C13 to CNS 60799 (Taiwan) Line Cord
4L67A08363 AX8B 4.3m, 10A 125V, C13 to CNS 10917 (Taiwan) Line Cord
81Y2389 6531 4.3m, 10A/250V, C13 to 76 CNS 10917-3 (Taiwan) Line Cord
81Y2388 6530 4.3m, 13A/125V, C13 to CNS 10917 (Taiwan) Line Cord
39Y7923 6215 2.8m, 10A/250V, C13 to BS 1363/A (UK) Line Cord
81Y2377 6577 4.3m, 10A/230V, C13 to BS 1363/A (UK) Line Cord
90Y3016 6313 2.8m, 10A/120V, C13 to NEMA 5-15P (US) Line Cord
46M2592 A1RF 2.8m, 10A/250V, C13 to NEMA 6-15P Line Cord
00WH545 6401 2.8m, 13A/120V, C13 to NEMA 5-15P (US) Line Cord
4L67A08359 6370 4.3m, 10A/125V, C13 to NEMA 5-15P (US) Line Cord
4L67A08361 6373 4.3m, 10A/250V, C13 to NEMA 6-15P (US) Line Cord
4L67A08360 AX8A 4.3m, 13A/120V, C13 to NEMA 5-15P (US) Line Cord

For the -48V DC Power Supply, the following power cable is supported.

Table 63. -48V DC power cable
Part number Feature code Description
CTO only B93F ThinkSystem 2.5m,DC Cable

Systems management

The SR650 supports the following systems management tools:

Lenovo XClarity Controller

The SR650 server contains Lenovo XClarity Controller (XCC), which provides advanced service-processor control, monitoring, and alerting functions. XClarity Controller offers three functional levels: Standard, Advanced, and Enterprise.

By default, the SR650 server includes XClarity Controller Standard features, and it can be upgraded to Advanced or Enterprise functionality by using the Features on Demand (FoD) upgrades.

XClarity Controller Standard offers the following capabilities:

  • Gathering and viewing system information and inventory
  • Monitoring system status and health
  • Alerting and notifications
  • Event logging
  • Configuring network connectivity
  • Configuring security
  • Updating system firmware
  • Configuring server settings and devices
  • Real-time power usage monitoring
  • Remotely controlling server power (Power on, Power off, Restart)
  • Managing FoD activation keys
  • Redirecting serial console via IPMI
  • Capturing the video display contents when an operating system hang condition is detected 

XClarity Controller Advanced Upgrade adds the following functionality to the Standard features:

  • Remotely viewing video with the following graphics resolutions:
    • Up to 1600x1200 with up to 23 bits per pixel; or
    • Up to 1920x1200 with up to 15 bits per pixel
  • Remotely accessing the server using the keyboard and mouse from a remote client
  • Remotely deploying an operating system
  • Syslog alerting
  • Redirecting serial console via SSH
  • Displaying graphics for real-time and historical power usage data and temperature

XClarity Controller Enterprise Upgrade adds the following functionality to the Advanced features:

  • Capping power usage
  • Mapping the ISO and image files located on the local client as virtual drives for use by the server
  • Mounting the remote ISO and image files via HTTPS, SFTP, CIFS, and NFS
  • Collaborating across up to six users of the virtual console
  • Controlling quality and bandwidth usage

The XClarity Controller provides remote server management through industry-standard interfaces:

  • Intelligent Platform Management Interface (IPMI) Version 2.0
  • Simple Network Management Protocol (SNMP) Version 3
  • Common Information Model (CIM)
  • Data Center Manageability Interface (DCMI) Version 1.5
  • Redfish REpresentational State Transfer (REST) API
  • Web browser with HTML5 support
  • Command-line interface
  • Virtual Operator Panel with XClarity Mobile App via the front USB port with XClarity Controller access

Virtual Operator Panel provides quick access to system status, firmware, network, health, and alerts information. With proper authentication, it also allows to configure systems management and network settings and to control system power (Power on, Power off, Restart). The Virtual Operator Panel can be accessed from the XClarity Mobile App running on the Android or iOS mobile device that is connected to the front USB port with XClarity Controller access (See Components and connectors).

Note: Depending on the system settings, the front USB port can be assigned to XClarity Controller for management functions, or to the system as a regular USB 2.0 port, or switched between two functions by using the system ID button.

The following table lists the XClarity Controller FoD upgrades.

Table 64. XClarity Controller FoD upgrades
Description Part number Feature code Maximum quantity
ThinkSystem XClarity Controller Standard to Advanced Upgrade 4L47A09132 AVUT 1
ThinkSystem XClarity Controller Standard to Enterprise Upgrade None* AUPW 1
ThinkSystem XClarity Controller Advanced to Enterprise Upgrade 4L47A09133 None** 1

* Factory-installed only.
** Field upgrade only.

Configuration notes:

  • For factory-installed upgrades, either Standard to Advanced Upgrade (feature AVUT) or Standard to Enterprise Upgrade (feature AUPW) can be selected, but not both.
  • For field upgrades, the Advanced to Enterprise Upgrade (4L47A09133) requires the Standard to Advanced Upgrade to be activated on the server previously with either the factory-installed feature AVUT or field upgrade 4L47A09132.

Light path diagnostics

All SR650 server models include basic light path diagnostics, which provides the system LEDs on the front of the server (see Components and connectors) and the LEDs near the monitored components (for example, the DIMM error LEDs on the system board).

Lenovo XClarity Provisioning Manager

Lenovo XClarity Provisioning Manager (LXPM) is a UEFI-based application embedded in ThinkSystem servers and accessible via the F1 key during system boot.

LXPM provides the following functions:

  • Graphical UEFI Setup
  • System inventory information and VPD update
  • System firmware updates (UEFI and XCC)
  • RAID setup wizard
  • OS installation wizard (including unattended OS installation)
  • Diagnostics functions

Lenovo XClarity Essentials

Lenovo offers the following XClarity Essentials software tools that can help you set up, use, and maintain the server at no additional cost:

  • Lenovo Essentials OneCLI

    OneCLI is a collection of server management tools that uses a command line interface program to manage firmware, hardware, and operating systems. It provides functions to collect full system health information (including health status), configure system settings, and update system firmware and drivers.

  • Lenovo Essentials UpdateXpress

    The UpdateXpress tool is a standalone GUI application for firmware and device driver updates that enables you to maintain your server firmware and device drivers up-to-date and help you avoid unnecessary server outages. The tool acquires and deploys individual updates and UpdateXpress System Packs (UXSPs) which are integration-tested bundles.

  • Lenovo Essentials Bootable Media Creator

    The Bootable Media Creator (BOMC) tool is used to create bootable media for offline firmware update.

For more information and downloads, visit the Lenovo XClarity Essentials web page:
http://support.lenovo.com/us/en/documents/LNVO-center

Lenovo XClarity Administrator

Lenovo XClarity Administrator is a centralized resource management solution designed to reduce complexity, speed response, and enhance the availability of Lenovo systems and solutions. It provides agent-free hardware management for ThinkSystem servers, in addition to ThinkServer, System x, and Flex System servers. The administration dashboard is based on HTML 5 and allows fast location of resources so tasks can be run quickly.

Because Lenovo XClarity Administrator does not require any agent software to be installed on the managed endpoints, there are no CPU cycles spent on agent execution, and no memory is used, which means that up to 1GB of RAM and 1 - 2% CPU usage is saved, compared to a typical managed system where an agent is required.

Lenovo XClarity Administrator is an optional software component for the SR650. The software can be downloaded and used at no charge to discover and monitor the SR650 and to manage firmware upgrades.

If software support is required for Lenovo XClarity Administrator, or premium features such as configuration management and operating system deployment are required, Lenovo XClarity Pro software subscription should be ordered. Lenovo XClarity Pro is licensed on a per managed system basis, that is, each managed Lenovo system requires a license.

The following table lists the Lenovo XClarity software license options.

Table 65. Lenovo XClarity Pro ordering information
Part number Feature code Description
00MT201 1339 Lenovo XClarity Pro, per Managed Endpoint w/1 Yr SW S&S
00MT202 1340 Lenovo XClarity Pro, per Managed Endpoint w/3 Yr SW S&S
00MT203 1341 Lenovo XClarity Pro, per Managed Endpoint w/5 Yr SW S&S
7S0X000HWW SAYV Lenovo XClarity Pro, per Managed Endpoint w/6 Yr SW S&S
7S0X000JWW SAYW Lenovo XClarity Pro, per Managed Endpoint w/7 Yr SW S&S

Lenovo XClarity Administrator offers the following standard features that are available at no charge:

  • Auto-discovery and monitoring of Lenovo systems
  • Firmware updates and compliance enforcement
  • External alerts and notifications via SNMP traps, syslog remote logging, and e-mail
  • Secure connections to managed endpoints
  • NIST 800-131A or FIPS 140-2 compliant cryptographic standards between the management solution and managed endpoints
  • Integration into existing higher-level management systems such as cloud automation and orchestration tools through REST APIs, providing extensive external visibility and control over hardware resources
  • An intuitive, easy-to-use GUI
  • Scripting with Windows PowerShell, providing command-line visibility and control over hardware resources

Lenovo XClarity Administrator offers the following premium features that require an optional Pro license:

  • Pattern-based configuration management that allows to define configurations once and apply repeatedly without errors when deploying new servers or redeploying existing servers without disrupting the fabric
  • Bare-metal deployment of operating systems and hypervisors to streamline infrastructure provisioning

For more information, refer to the Lenovo XClarity Administrator Product Guide:
http://lenovopress.com/tips1200

Lenovo XClarity Integrators

Lenovo also offers software plug-in modules, Lenovo XClarity Integrators, to manage physical infrastructure from leading external virtualization management software tools including those from Microsoft and VMware.

These integrators are offered at no charge, however if software support is required, a Lenovo XClarity Pro software subscription license should be ordered.

Lenovo XClarity Integrators offer the following additional features:

  • Ability to discover, manage, and monitor Lenovo server hardware from VMware vCenter or Microsoft System Center
  • Deployment of firmware updates and configuration patterns to Lenovo x86 rack servers and Flex System from the virtualization management tool
  • Non-disruptive server maintenance in clustered environments that reduces workload downtime by dynamically migrating workloads from affected hosts during rolling server updates or reboots
  • Greater service level uptime and assurance in clustered environments during unplanned hardware events by dynamically triggering workload migration from impacted hosts when impending hardware failures are predicted

For more information about all the available Lenovo XClarity Integrators, see the Lenovo XClarity Administrator Product Guide: https://lenovopress.com/tips1200-lenovo-xclarity-administrator

Lenovo XClarity Energy Manager

Lenovo XClarity Energy Manager (LXEM) is a power and temperature management solution for data centers. It is an agent-free, web-based console that enables you to monitor and manage power consumption and temperature in your data center through the management console. It enables server density and data center capacity to be increased through the use of power capping.

LXEM is a licensed product. A single-node LXEM license is included with the XClarity Controller Enterprise upgrade as described in the Remote Management section. If your server does not have the XCC Enterprise upgrade, Energy Manager licenses can be ordered as shown in the following table.

Table 66. Lenovo XClarity Energy Manager
Part number Description
4L40E51621 Lenovo XClarity Energy Manager Node License (1 license needed per server)

For more information about XClarity Energy Manager, see the following resources:

Lenovo Capacity Planner

Lenovo Capacity Planner is a power consumption evaluation tool that enhances data center planning by enabling IT administrators and pre-sales professionals to understand various power characteristics of racks, servers, and other devices. Capacity Planner can dynamically calculate the power consumption, current, British Thermal Unit (BTU), and volt-ampere (VA) rating at the rack level, improving the planning efficiency for large scale deployments.

For more information, refer to the Capacity Planner web page:
http://datacentersupport.lenovo.com/us/en/solutions/lnvo-lcp

Security

The ThinkSystem SR650 server offers the following security features:

  • Power-on password
  • Administrator's password
  • Secure firmware updates
  • Onboard Trusted Platform Module (TPM) version 1.2 or 2.0 (configurable UEFI system setting)
  • Trusted Cryptographic Module (TCM) (optional; PRC only)
  • Nationz Trusted Platform Module v2.0 (optional; PRC only)
  • Lockable front bezel (optional)
  • Self-encrypting drives (SEDs) with support for enterprise key managers - see the SED encryption key management section
  • Lenovo Business Vantage security software (optional; PRC only)

The server is NIST SP 800-147B compliant.

The following table lists the security options that are available for the ThinkSystem SR650 server.

Table 67. Security options
Part number Feature code Description Maximum quantity
Lockable front bezel
7Z17A02580 AURX ThinkSystem 2U Security Bezel 1
Trusted Cryptographic Module (PRC only)
None* AVKE ThinkSystem Trusted Cryptographic Module 1
Trusted Platform Module (PRC only)
None* B22N ThinkSystem Nationz Trusted Platform Module v2.0 1

* Factory-installed only; no field upgrade.

Lenovo Business Vantage is a security software tool suite (available only in PRC) designed to work with the TCM for enhanced security, to keep user data safe, and to erase confidential data completely from a drive.

Lenovo Business Vantage provides the following features:

  • Encrypts files to ensure data safety by using the TCM.
  • Erases confidential data from a drive.
  • Prohibits unauthorized access to the USB port of devices.
  • Encrypts files to ensure data security on a USB storage device.

Intel Transparent Supply Chain

Add a layer of protection in your data center and have peace of mind that the server hardware you bring into it is safe authentic and with documented, testable, and provable origin.

Lenovo has one of the world’s best supply chains, as ranked by Gartner Group, backed by extensive and mature supply chain security programs that exceed industry norms and US Government standards. Now we are the first Tier 1 manufacturer to offer Intel® Transparent Supply Chain in partnership with Intel, offering you an unprecedented degree of supply chain transparency and assurance.

To enable Intel Transparent Supply Chain for the Intel-based servers in your order, add the following feature code in the DCSC configurator, under the Security tab.

Table 68. Intel Transparent Supply Chain ordering information
Feature code Description
BB0P Intel Transparent Supply Chain

For more information on this offering, see the paper Introduction to Intel Transparent Supply Chain on Lenovo ThinkSystem Servers, available from https://lenovopress.com/lp1434-introduction-to-intel-transparent-supply-chain-on-thinksystem-servers.

Rack installation

The following table lists the rack installation options that are available for the ThinkSystem SR650 server.

Table 69. Rack installation options
Part number Feature code Description Maximum quantity
4-post rail kits
7M27A05702 AXCA ThinkSystem Tool-less Slide Rail 1
7M27A05700 AXCH ThinkSystem Tool-less Slide Rail Kit with 2U CMA 1
4M17A07274 AXFN ThinkSystem Screw-in Slide Rail 1
4M17A07280 B0TD ThinkSystem Screw-in Slide Rail Kit with 2U CMA 1
  AXFM ThinkSystem Tool-less Friction Rail 1
4M17A07273 BK7W ThinkSystem Toolless Friction Rail v2 1
Cable management arm (CMA) upgrade
7M27A05698 None^ ThinkSystem 2U CMA Upgrade Kit for Tool-less Slide Rail 1*
4M17A07275 AXFU ThinkSystem 2U CMA Upgrade Kit for Screw-in Slide Rail 1**
Front VGA port
4XH7A83033 BMNL ThinkSystem SR550/SR590/SR650 EIA Latch w/ VGA Upgrade Kit v2 1
7Z17A02578 AUS8 ThinkSystem 2U EIA Latch w/ VGA Upgrade Kit 1

^ Field upgrade only.
* The CMA Upgrade Kit for Tool-less Slide Rail is supported with the Tool-less Slide Rail (7M27A05702) only.
** The CMA Upgrade Kit for Screw-in Slide Rail is supported with the Screw-in Slide Rail (4M17A07274) only.

The following table summarizes the rail kit features and specifications.

Table 70. Rail kit features and specifications summary
Feature Tool-less Slide Rail Screw-in Slide Rail Tool-less Friction Rail
Without CMA With CMA Without CMA With CMA
Part number 7M27A05702 7M27A05700 4M17A07274 4M17A07280 4M17A07273
CMA 7M27A05698 Included 4M17A07275 Included  No support
Rail length 730 mm
(28.74 in.)
807 mm
(31.8 in.)
836.8 mm
(32.9 in.)
836.8 mm
(32.9 in.)
728.1 mm
(28.7 in.)
Rail type Full-out slide (ball bearing) Full-out slide (ball bearing) Half-out slide (friction)
Tool-less installation Yes No Yes
In-rack server maintenance Yes Yes No
1U PDU support Yes Yes Yes
0U PDU support Limited* Limited* Limited**
Rack type IBM and Lenovo 4-post,
IEC standard-compliant
IBM and Lenovo 4-post,
IEC standard-compliant
IBM and Lenovo 4-post,
IEC standard-compliant
Mounting holes Square or round Square, round, or threaded Square or round
Mounting flange thickness 2 mm (0.08 in.) –
3.3 mm (0.13 in.)
2 mm (0.08 in.) –
3.3 mm (0.13 in.)
2 mm (0.08 in.) –
3.3 mm (0.13 in.)
Distance between front
and rear mounting flanges^
609.6 mm (24 in.) –
863.6 mm (34 in.)
609.6 mm (24 in.) –
812.8 mm (32 in.)
609.6 mm (24 in.) –
863.6 mm (34 in.)

* If a 0U PDU is used, the rack cabinet must be at least 1100 mm (43.31 in.) deep if no CMA is used, or at least 1200 mm (47.24 in.) deep if a CMA is used.
** If a 0U PDU used, the rack must be at least 1000 mm (39.37 in.) deep.
^ Measured when mounted on the rack, from the front surface of the front mounting flange to the rear most point of the rail.

Operating system support

The SR650 server with 2nd Gen Intel Xeon SP processors supports the following operating systems:

  • Microsoft Windows Server 2016
  • Microsoft Windows Server 2019
  • Microsoft Windows Server 2022
  • Red Hat Enterprise Linux 7.6
  • Red Hat Enterprise Linux 7.7
  • Red Hat Enterprise Linux 7.8
  • Red Hat Enterprise Linux 7.9
  • Red Hat Enterprise Linux 8.0
  • Red Hat Enterprise Linux 8.1
  • Red Hat Enterprise Linux 8.2
  • Red Hat Enterprise Linux 8.3
  • Red Hat Enterprise Linux 8.4
  • Red Hat Enterprise Linux 8.5
  • Red Hat Enterprise Linux 8.6
  • Red Hat Enterprise Linux 8.7
  • Red Hat Enterprise Linux 8.8
  • Red Hat Enterprise Linux 8.9
  • Red Hat Enterprise Linux 9.0
  • Red Hat Enterprise Linux 9.1
  • Red Hat Enterprise Linux 9.2
  • Red Hat Enterprise Linux 9.3
  • SUSE Linux Enterprise Server 12 SP4
  • SUSE Linux Enterprise Server 12 SP5
  • SUSE Linux Enterprise Server 12 Xen SP4
  • SUSE Linux Enterprise Server 12 Xen SP5
  • SUSE Linux Enterprise Server 15
  • SUSE Linux Enterprise Server 15 SP1
  • SUSE Linux Enterprise Server 15 SP2
  • SUSE Linux Enterprise Server 15 SP3
  • SUSE Linux Enterprise Server 15 SP4
  • SUSE Linux Enterprise Server 15 SP5
  • SUSE Linux Enterprise Server 15 Xen
  • SUSE Linux Enterprise Server 15 Xen SP1
  • SUSE Linux Enterprise Server 15 Xen SP2
  • SUSE Linux Enterprise Server 15 Xen SP3
  • SUSE Linux Enterprise Server 15 Xen SP4
  • SUSE Linux Enterprise Server 15 Xen SP5
  • Ubuntu 22.04 LTS 64-bit
  • VMware ESXi 6.5 U2
  • VMware ESXi 6.5 U3
  • VMware ESXi 6.7 U1
  • VMware ESXi 6.7 U2
  • VMware ESXi 6.7 U3
  • VMware ESXi 7.0
  • VMware ESXi 7.0 U1
  • VMware ESXi 7.0 U2
  • VMware ESXi 7.0 U3
  • VMware ESXi 8.0
  • VMware ESXi 8.0 U1
  • VMware ESXi 8.0 U2

The SR650 server with 1st Gen Intel Xeon SP processors supports the following operating systems:

  • Microsoft Windows Server 2012 R2
  • Microsoft Windows Server 2016
  • Microsoft Windows Server 2019
  • Microsoft Windows Server 2022
  • Microsoft Windows Server, version 1709
  • Microsoft Windows Server, version 1803
  • Red Hat Enterprise Linux 6.9 x64
  • Red Hat Enterprise Linux 6.10 x64
  • Red Hat Enterprise Linux 7.3
  • Red Hat Enterprise Linux 7.4
  • Red Hat Enterprise Linux 7.5
  • Red Hat Enterprise Linux 7.6
  • Red Hat Enterprise Linux 7.7
  • Red Hat Enterprise Linux 7.8
  • Red Hat Enterprise Linux 7.9
  • Red Hat Enterprise Linux 8.0
  • Red Hat Enterprise Linux 8.1
  • Red Hat Enterprise Linux 8.2
  • Red Hat Enterprise Linux 8.3
  • Red Hat Enterprise Linux 8.4
  • Red Hat Enterprise Linux 8.5
  • Red Hat Enterprise Linux 8.6
  • Red Hat Enterprise Linux 8.7
  • Red Hat Enterprise Linux 8.8
  • Red Hat Enterprise Linux 9.0
  • Red Hat Enterprise Linux 9.1
  • Red Hat Enterprise Linux 9.2
  • SUSE Linux Enterprise Server 11 Xen x64 SP4
  • SUSE Linux Enterprise Server 11 x64 SP4
  • SUSE Linux Enterprise Server 12 SP2
  • SUSE Linux Enterprise Server 12 SP3
  • SUSE Linux Enterprise Server 12 SP4
  • SUSE Linux Enterprise Server 12 SP5
  • SUSE Linux Enterprise Server 12 Xen SP2
  • SUSE Linux Enterprise Server 12 Xen SP3
  • SUSE Linux Enterprise Server 12 Xen SP4
  • SUSE Linux Enterprise Server 12 Xen SP5
  • SUSE Linux Enterprise Server 15
  • SUSE Linux Enterprise Server 15 SP1
  • SUSE Linux Enterprise Server 15 SP2
  • SUSE Linux Enterprise Server 15 SP3
  • SUSE Linux Enterprise Server 15 SP4
  • SUSE Linux Enterprise Server 15 SP5
  • SUSE Linux Enterprise Server 15 Xen
  • SUSE Linux Enterprise Server 15 Xen SP1
  • SUSE Linux Enterprise Server 15 Xen SP2
  • SUSE Linux Enterprise Server 15 Xen SP3
  • SUSE Linux Enterprise Server 15 Xen SP4
  • SUSE Linux Enterprise Server 15 Xen SP5
  • Ubuntu 22.04 LTS 64-bit
  • VMware ESXi 6.0 U3
  • VMware ESXi 6.5
  • VMware ESXi 6.5 U1
  • VMware ESXi 6.5 U2
  • VMware ESXi 6.5 U3
  • VMware ESXi 6.7
  • VMware ESXi 6.7 U1
  • VMware ESXi 6.7 U2
  • VMware ESXi 6.7 U3
  • VMware ESXi 7.0
  • VMware ESXi 7.0 U1
  • VMware ESXi 7.0 U2
  • VMware ESXi 7.0 U3
  • VMware ESXi 8.0
  • VMware ESXi 8.0 U1
  • VMware ESXi 8.0 U2

For a complete list of supported, certified and tested operating systems, plus additional details and links to relevant web sites, see the Operating System Interoperability Guide: https://lenovopress.com/osig#servers=sr650-7x05-7x06-sp-gen-2

For configure-to-order configurations, the server can be preloaded with VMware ESXi installed on M.2 cards. Ordering information is listed in the following table.

Table 71. VMware ESXi preload
Part number Feature code Description
CTO only B3VW VMware ESXi 6.5 U2 (Factory Installed)
CTO only B6U0 VMware ESXi 6.5 U3 (factory installed)
CTO only B3VX VMware ESXi 6.7 (Factory Installed)
CTO only B4XA VMware ESXi 6.7 U1 (Factory Installed)
CTO only B6U1 VMware ESXi 6.7 U2 (factory installed)
CTO only B88T VMware ESXi 6.7 U3 (factory installed)
CTO only BBZG VMware ESXi 7.0 (Factory Installed)
CTO only BE5E VMware ESXi 7.0 U1 (Factory Installed)
CTO only BHSR VMware ESXi 7.0 U2 (Factory Installed)
CTO only BMEY VMware ESXi 7.0 U3 (Factory Installed)
CTO only BMT5 VMware ESXi 8.0 (Factory Installed)
CTO only BQ8S VMware ESXi 8.0 U1 (Factory Installed)
CTO only BYC7 VMware ESXi 8.0 U2 (Factory Installed)

Physical and electrical specifications

The SR650 has the following overall physical dimensions, excluding components that extend outside the standard chassis, such as EIA flanges, front security bezel (if any), and power supply handles:

  • Width: 445 mm (17.5 inches)
  • Height: 87 mm (3.4 inches)
  • Depth: 764 mm (30.1 inches)

The following table lists the detailed dimensions. See the figure below for the definition of each dimension.

Table 72. Detailed dimensions
Dimension Description
482 mm Xa = Width, to the outsides of the front EIA flanges
435 mm Xb = Width, to the rack rail mating surfaces
445 mm Xc = Width, to the outer most chassis body feature
87 mm Ya = Height, from the bottom of chassis to the top of the chassis
698 mm Za = Depth, from the rack flange mating surface to the rearmost I/O port surface
730 mm Zb = Depth, from the rack flange mating surface to the rearmost feature of the chassis body
727 mm Zc = Depth, from the rack flange mating surface to the rearmost feature such as power supply handle
34 mm Zd = Depth, from the forwardmost feature on front of EIA flange to the rack flange mating surface
47 mm Ze = Depth, from the front of security bezel (if applicable) or forwardmost feature to the rack flange mating surface

Rack server dimensions
Figure 12. Server dimensions

The shipping (cardboard packaging) dimensions of the SR650 are as follows:

  • Width: 592 mm (23.3 inches)
  • Height: 282 mm (11.1 inches)
  • Depth: 992 mm (39.1 inches)

The server has the following weight:

  • Minimum configuration: 19 kg (41.9 lb)
  • Maximum configuration: 32 kg (70.5 lb)

Electrical specifications for AC power supplies:

  • 100 - 127 (nominal) V AC; 50 Hz / 60 Hz
  • 200 - 240 (nominal) V AC; 50 Hz / 60 Hz
  • 180 - 300 V DC (HVDC; supported in PRC only)

Power load and inlet current

The following table lists the maximum system power load, rated inlet current, and system heat output based on the power supply and source voltage.

Table 73. Rated system power, inlet current, and system heat output
Power supply Source voltage Maximum power
load per system
(two power supplies)
Rated current
per inlet
System
heat output
550 W Platinum 100 - 127 V AC 722 W 6.2 A 2463 BTU/hour
200 - 240 V AC 704 W 3 A 2402 BTU/hour
180 - 300 V DC 702 W 2.5 A 2395 BTU/hour
750 W Platinum 100 - 127 V AC 984 W 8.4 A 3357 BTU/hour
200 - 240 V AC 958 W 4.1 A 3269 BTU/hour
180 - 300 V DC 958 W 3.5 A 3269 BTU/hour
750 W Titanium 200 - 240 V AC 949 W 4.1 A 3238 BTU/hour
180 - 300 V DC 948 W 3.5 A 3235 BTU/hour
1100 W Platinum 100 - 127 V AC 1382 W 12 A 4715 BTU/hour
200 - 240 V AC 1408 W 6 A 4804 BTU/hour
180 - 300 V DC 1408 W 5.1 A 4804 BTU/hour
1600 W Platinum 200 - 240 V AC 2068 W 8.7 A 7056 BTU/hour
180 - 300 V DC 2024 W 7.3 A 6906 BTU/hour

Operating environment

The SR650 server complies with ASHRAE class A2 specifications. The server performance might be impacted when the operating temperature is outside the ASHRAE A2 specifications. Depending on the hardware configuration, some server models comply with ASHRAE class A3 and class A4 specifications.

To comply with ASHRAE class A3 and class A4 specifications, the server models must meet the following hardware configuration requirements at the same time:

  • Two power supplies installed
  • NVMe drives not installed
  • M.2 5100 or 5300 SSDs not installed
  • QLogic QL41134 PCIe 10Gb 4-Port Base-T Ethernet Adapter not installed
  • Mellanox ConnectX-6 and Innova-2 FPGA adapters not installed
  • PCIe flash adapters not installed
  • Persistent memory modules not installed
  • Graphic processing units (GPUs) not installed
  • Processors with TDP more than or equal to 150 W, or Gold 6230N processors not installed

Temperature and humidity

The SR650 server is supported in the following environment:

  • Air temperature:
    • Operating:
      • ASHRAE Class A4: 5 °C - 45 °C (41 °F - 113 °F); for altitudes above 900 m (2,953 ft), decrease the maximum ambient temperature by 1 °C for every 125-m (410-ft) increase in altitude
      • ASHRAE Class A3: 5 °C - 40 °C (41 °F - 104 °F); for altitudes above 900 m (2,953 ft), decrease the maximum ambient temperature by 1 °C for every 175-m (574-ft) increase in altitude
      • ASHRAE Class A2: 10 °C - 35 °C (50 °F - 95 °F); for altitudes above 900 m (2,953 ft), decrease the maximum ambient temperature by 1 °C for every 300-m (984-ft) increase in altitude
    • Non-operating: 5 °C - 45 °C (41 °F - 113 °F)
    • Storage: -40 °C - +60 °C (-40 °F - 140 °F)
  • Maximum altitude: 3,050 m (10,000 ft)
  • Humidity:
    • Operating:
      • ASHRAE Class A4: 8% - 90% (non-condensing); maximum dew point: 24 °C (75 °F)
      • ASHRAE Class A3: 8% - 85% (non-condensing); maximum dew point: 24 °C (75 °F)
      • ASHRAE Class A2: 8% - 80% (non-condensing); maximum dew point: 21 °C (70 °F)
    • Storage: 8% - 90% (non-condensing)

Acoustical noise emissions

The server has the following acoustic noise emissions declaration:

  • Minimum configuration:
    • Operating: 5.1 bels
    • Idle: 4.9 bels
  • Maximum configuration:
    • Operating: 6.2 bels
    • Idle: 6.1 bels

Notes:

  • These sound levels were measured in controlled acoustical environments according to procedures specified by ISO7779 and are reported in accordance with ISO 9296.
  • The declared acoustic sound levels are based on the configurations, which may change slightly depending on configuration/conditions, for example high-power processors and GPUs, and high-power network adapters.
    • Min config: 1x 85W CPU, 2x 16GB RDIMM, 1x SAS HDD, PHY 4x1G RJ45, 1x 550W PSU
    • Max config: 2x 145W CPU, 24x 64GB RDIMM, 24x SAS HDD, PHY 4x10G SFP+, 24i Raid, 2x 1100W PSU
  • Government regulations (such as those prescribed by OSHA or European Community Directives) may govern noise level exposure in the workplace and may apply to you and your server installation. The actual sound pressure levels in your installation depend upon a variety of factors, including the number of racks in the installation; the size, materials, and configuration of the room; the noise levels from other equipment; the room ambient temperature, and employee's location in relation to the equipment. Further, compliance with such government regulations depends on a variety of additional factors, including the duration of employees' exposure and whether employees wear hearing protection. Lenovo recommends that you consult with qualified experts in this field to determine whether you are in compliance with the applicable regulations.

Shock and vibration

The server has the following vibration and shock limits:

  • Vibration:
    • Operating: 0.21 G rms at 5 Hz to 500 Hz for 15 minutes across 3 axes
    • Non-operating: 1.04 G rms at 2 Hz to 200 Hz for 15 minutes across 6 surfaces
  • Shock:
    • Operating: 15 G for 3 milliseconds in each direction (positive and negative X, Y, and Z axes)
    • Non-operating:
      • 12 kg - 22 kg: 50 G for 152 in./sec velocity change across 6 surfaces
      • 23 kg - 31 kg: 35 G for 152 in./sec velocity change across 6 surfaces

Particulate contamination

Airborne particulates (including metal flakes or particles) and reactive gases acting alone or in combination with other environmental factors such as humidity or temperature might damage the system that might cause the system to malfunction or stop working altogether.

The following specifications indicate the limits of particulates that the system can tolerate:

  • Reactive gases:
    • The copper reactivity level shall be less than 200 Angstroms per month (Å/month)
    • The silver reactivity level shall be less than 200 Å/month
  • Airborne particulates:
    • The room air should be continuously filtered with MERV 8 filters.
    • Air entering a data center should be filtered with MERV 11 or preferably MERV 13 filters.
    • The deliquescent relative humidity of the particulate contamination should be more than 60% RH
    • Environment must be free of zinc whiskers

For additional information, see the Specifications section of the documentation for the server, available from the Lenovo Documents site, https://pubs.lenovo.com/

Warranty upgrades and post-warranty support

The SR650 server has a one-year (7X05) or three-year (Machine Type 7X06) warranty.

Our global network of regional support centers offers consistent, local-language support enabling you to vary response times and level of service to match the criticality of your support needs:

  • Standard Next Business Day – Best choice for non-essential systems requiring simple maintenance.
  • Premier Next Business Day – Best choice for essential systems requiring technical expertise from senior-level Lenovo engineers.
  • Premier 24x7 4-Hour Response – Best choice for systems where maximum uptime is critical.
  • Premier Enhanced Storage Support 24x7 4-Hour Response – Best choice for storage systems where maximum uptime is critical.

For more information, consult the brochure Lenovo Operational Support Services for Data Centers Services.

Services

Lenovo Data Center Services empower you at every stage of your IT lifecycle. From expert advisory and strategic planning to seamless deployment and ongoing support, we ensure your infrastructure is built for success. Our comprehensive services accelerate time to value, minimize downtime, and free your IT staff to focus on driving innovation and business growth.

Note: Some service options may not be available in all markets or regions. For more information, go to https://lenovolocator.com/. For information about Lenovo service upgrade offerings that are available in your region, contact your local Lenovo sales representative or business partner.

In this section:

Lenovo Advisory Services

Lenovo Advisory Services simplify the planning process, enabling customers to build future-proofed strategies in as little as six weeks. Consultants provide guidance on projects including VM migration, storage, backup and recovery, and cost management to accelerate time to value, improve cost efficiency, and build a flexibly scalable foundation.

  • Assessment Services

    An Assessment helps solve your IT challenges through an onsite, multi-day session with a Lenovo technology expert. We perform a tools-based assessment which provides a comprehensive and thorough review of a company's environment and technology systems. In addition to the technology based functional requirements, the consultant also discusses and records the non-functional business requirements, challenges, and constraints. Assessments help organizations like yours, no matter how large or small, get a better return on your IT investment and overcome challenges in the ever-changing technology landscape.

  • Design Services

    Professional Services consultants perform infrastructure design and implementation planning to support your strategy. The high-level architectures provided by the assessment service are turned into low level designs and wiring diagrams, which are reviewed and approved prior to implementation. The implementation plan will demonstrate an outcome-based proposal to provide business capabilities through infrastructure with a risk-mitigated project plan.

Lenovo Plan & Design Services

Unlock faster time to market with our tailored, strategic design workshops to align solution approaches with your business goals and technical requirements. Leverage our deep solution expertise and end-to-end delivery partnership to meet your goals efficiently and effectively.

Lenovo Deployment, Migration, and Configuration Services

Optimize your IT operations by shifting labor-intensive functions to Lenovo's skilled technicians for seamless on-site or remote deployment, configuration, and migration. Enjoy peace of mind, faster time to value, and comprehensive knowledge sharing with your IT staff, backed by our best-practice methodology.

  • Deployment Services for Storage and ThinkAgile

    A comprehensive range of remote and onsite options tailored specifically for your business needs to ensure your storage and ThinkAgile hardware are fully operational from the start.

  • Hardware Installation Services

    A full-range, comprehensive setup for your hardware, including unpacking, inspecting, and positioning components to ensure your equipment is operational and error-free for the most seamless and efficient installation experience, so you can quickly benefit from your investments.

  • DM/DG File Migration Services

    Take the burden of file migration from your IT’s shoulders. Our experts will align your requirements and business objectives to the migration plans while coordinating with your team to plan and safely execute the data migration to your storage platforms.

  • DM/DG/DE Health Check Services

    Our experts perform proactive checks of your Firmware and system health to ensure your machines are operating at peak and optimal efficiency to maximize up-time, avoid system failures, ensure the security of IT solutions and simplify maintenance.

  • Factory Integrated Services

    A suite of value-added offerings provided during the manufacturing phase of a server or storage system that reduces time to value. These services aim at improving your hardware deployment experience and enhance the quality of a standard configuration before it arrives at your facility.

Lenovo Support Services

In addition to response time options for hardware parts, repairs, and labor, Lenovo offers a wide array of additional support services to ensure your business is positioned for success and longevity. Our goal is to reduce your capital outlays, mitigate your IT risks, and accelerate your time to productivity.

  • Premier Support for Data Centers

    Your direct line to the solution that promises the best, most comprehensive level of support to help you fully unlock the potential of your data center.

  • Premier Enhanced Storage Support (PESS)

    Gain all the benefits of Premier Support for Data Centers, adding dedicated storage specialists and resources to elevate your storage support experience to the next level.

  • Committed Service Repair (CSR)

    Our commitment to ensuring the fastest, most seamless resolution times for mission-critical systems that require immediate attention to ensure minimal downtime and risk for your business. This service is only available for machines under the Premier 4-Hour Response SLA.

  • Multivendor Support Services (MVS)

    Your single point of accountability for resolution support across vast range of leading Server, Storage, and Networking OEMs, allowing you to manage all your supported infrastructure devices seamlessly from a single source.

  • Keep Your Drive (KYD)

    Protect sensitive data and maintain compliance with corporate retention and disposal policies to ensure your data is always under your control, regardless of the number of drives that are installed in your Lenovo server.

  • Technical Account Manager (TAM)

    Your single point of contact to expedite service requests, provide status updates, and furnish reports to track incidents over time, ensuring smooth operations and optimized performance as your business grows.

  • Enterprise Software Support (ESS)

    Gain comprehensive, single-source, and global support for a wide range of server operating systems and Microsoft server applications.

For more information, consult the brochure Lenovo Operational Support Services for Data Centers.

Lenovo Managed Services

Achieve peak efficiency, high security, and minimal disruption with Lenovo's always-on Managed Services. Our real-time monitoring, 24x7 incident response, and problem resolution ensure your infrastructure operates seamlessly. With quarterly health checks for ongoing optimization and innovation, Lenovo's remote active monitoring boosts end-user experience and productivity by keeping your data center's hardware performing at its best.

Lenovo Managed Services provides continuous 24x7 remote monitoring (plus 24x7 call center availability) and proactive management of your data center using state-of-the-art tools, systems, and practices by a team of highly skilled and experienced Lenovo services professionals.

Quarterly reviews check error logs, verify firmware & OS device driver levels, and software as needed. We’ll also maintain records of latest patches, critical updates, and firmware levels, to ensure you systems are providing business value through optimized performance.

Lenovo Sustainability Services

  • Asset Recovery Services

    Lenovo Asset Recovery Services (ARS) provides a secure, seamless solution for managing end-of-life IT assets, ensuring data is safely sanitized while contributing to a more circular IT lifecycle. By maximizing the reuse or responsible recycling of devices, ARS helps businesses meet sustainability goals while recovering potential value from their retired equipment. For more information, see the Asset Recovery Services offering page.

  • CO2 Offset Services

    Lenovo’s CO2 Offset Services offer a simple and transparent way for businesses to take tangible action on their IT footprint. By integrating CO2 offsets directly into device purchases, customers can easily support verified climate projects and track their contributions, making meaningful progress toward their sustainability goals without added complexity.

  • Lenovo Certified Refurbished

    Lenovo Certified Refurbished offers a cost-effective way to support IT circularity without compromising on quality and performance. Each device undergoes rigorous testing and certification, ensuring reliable performance and extending its lifecycle. With Lenovo’s trusted certification, you gain peace of mind while making a more sustainable IT choice.

Lenovo TruScale

Lenovo TruScale XaaS is your set of flexible IT services that makes everything easier. Streamline IT procurement, simplify infrastructure and device management, and pay only for what you use – so your business is free to grow and go anywhere.

Lenovo TruScale is  the unified solution that gives you simplified access to:

  • The industry’s broadest portfolio – from pocket to cloud – all delivered as a service
  • A single-contract framework for full visibility and accountability
  • The global scale to rapidly and securely build teams from anywhere
  • Flexible fixed and metered pay-as-you-go models with minimal upfront cost
  • The growth-driving combination of hardware, software, infrastructure, and solutions – all from one single provider with one point of accountability.

For information about Lenovo TruScale offerings that are available in your region, contact your local Lenovo sales representative or business partner.

Regulatory compliance

The ThinkSystem SR650 server conforms to the following regulations:

  • United States: FCC Part 15, Class A; UL 60950-1
  • Canada: ICES-003/NMB-03, Class A; CAN/CSA-C22.2 60950-1
  • Mexico: NOM-19
  • Argentina: IEC60950-1
  • European Union: CE Mark (EN55022 Class A, IEC/EN60950-1, EN55024, EN61000-3-2, EN61000-3-3)
  • Germany: TUV-GS (IEC/EN 60950-1, EK1-ITB2000)
  • Russia, Kazakhstan, Belarus: EAC (TR CU 004/2011, TR CU 020/2011)
  • China: CCC GB4943.1, GB9254 Class A, GB17625.1
  • India: BIS
  • Japan: VCCI, Class A
  • Taiwan: BSMI CNS13438, Class A; CNS14336-1
  • Korea: KN22, Class A; KN24
  • Australia/New Zealand: AS/NZS CISPR 22 Class A
  • Reduction of Hazardous Substances (ROHS)
  • Energy Star 3.0 (excluding configurations with Bronze 3204, Gold 5222, or Platinum 8256 processors)

Note: For more information on the Energy Star 3.0 certification, refer to the Energy Star 3.0 Certifications for ThinkSystem Servers publication:
http://lenovopress.com/lp1230

External drive enclosures

The server supports attachment to external drive enclosures using a RAID controller with external ports or a SAS host bus adapter. Adapters supported by the server are listed in the SAS adapters for external storage section.

Note: Information provided in this section is for ordering reference purposes only. For the operating system and adapter support details, refer to the interoperability matrix for a particular storage enclosure that can be found on the Lenovo Data Center Support web site:
http://datacentersupport.lenovo.com

Table 74. External drive enclosures
Model Description
4587HC1 Lenovo Storage D1212 Disk Expansion Enclosure (2U enclosure with 12x LFF drive bays)
4587HC2 Lenovo Storage D1224 Disk Expansion Enclosure (2U enclosure with 24x SFF drive bays)
6413HC1 Lenovo Storage D3284 High Density Expansion Enclosure (5U enclosure with 84x LFF drive bays)
7DAHCTO1WW Lenovo ThinkSystem D4390 Direct Attached Storage (4U enclosure with 90x LFF drive bays)

For details about supported drives, adapters, and cables, see the following Lenovo Press Product Guides:

External storage systems

Lenovo offers the ThinkSystem DE Series and ThinkSystem DM Series external storage systems for high-performance storage. See the DE Series and DM Series product guides for specific controller models, expansion enclosures and configuration options:

External backup units

The following table lists the external backup options that are offered by Lenovo.

Table 75. External backup options
Part number Description
External RDX USB drives
4T27A10725 ThinkSystem RDX External USB 3.0 Dock
External SAS tape backup drives
6160S7E IBM TS2270 Tape Drive Model H7S
6160S8E IBM TS2280 Tape Drive Model H8S
6160S9E IBM TS2290 Tape Drive Model H9S
External SAS tape backup autoloaders
6171S7R IBM TS2900 Tape Autoloader w/LTO7 HH SAS
6171S8R IBM TS2900 Tape Autoloader w/LTO8 HH SAS
6171S9R IBM TS2900 Tape Autoloader w/LTO9 HH SAS
External tape backup libraries
6741A1F IBM TS4300 3U Tape Library-Base Unit
6741A3F IBM TS4300 3U Tape Library-Expansion Unit
Full High 8 Gb Fibre Channel for TS4300
01KP938 LTO 7 FH Fibre Channel Drive
01KP954 LTO 8 FH Fibre Channel Drive
02JH837 LTO 9 FH Fibre Channel Drive
Half High 8 Gb Fibre Channel for TS4300
01KP936 LTO 7 HH Fibre Channel Drive
01KP952 LTO 8 HH Fibre Channel Drive
02JH835 LTO 9 HH Fibre Channel Drive
Half High 6 Gb SAS for TS4300
01KP937 LTO 7 HH SAS Drive
01KP953 LTO 8 HH SAS Drive
02JH836 LTO 9 HH SAS Drive

For more information, see the list of Product Guides in the Backup units category:
https://lenovopress.com/servers/options/backup

Fibre Channel SAN switches

Lenovo offers the ThinkSystem DB Series of Fibre Channel SAN switches for high-performance storage expansion. See the DB Series product guides for models and configuration options:

Rack cabinets

The following table lists the supported rack cabinets.

Table 76. Rack cabinets
ModelDescription
93072RX25U Standard Rack (1000mm)
93072PX25U Static S2 Standard Rack (1000mm)
7D6DA007WWThinkSystem 42U Onyx Primary Heavy Duty Rack Cabinet (1200mm)
7D6DA008WWThinkSystem 42U Pearl Primary Heavy Duty Rack Cabinet (1200mm)
7D6EA009WWThinkSystem 48U Onyx Primary Heavy Duty Rack Cabinet (1200mm)
7D6EA00AWWThinkSystem 48U Pearl Primary Heavy Duty Rack Cabinet (1200mm)
1410O42Lenovo EveryScale 42U Onyx Heavy Duty Rack Cabinet
1410P42Lenovo EveryScale 42U Pearl Heavy Duty Rack Cabinet
1410O48Lenovo EveryScale 48U Onyx Heavy Duty Rack Cabinet
1410P48Lenovo EveryScale 48U Pearl Heavy Duty Rack Cabinet
93604PX42U 1200mm Deep Dynamic Rack
93614PX42U 1200mm Deep Static Rack
93634PX42U 1100mm Dynamic Rack
93634EX42U 1100mm Dynamic Expansion Rack
93074RX42U Standard Rack (1000mm)
93084PX42U Enterprise Rack
93084EX42U Enterprise Expansion Rack

For specifications about these racks, see the Lenovo Rack Cabinet Reference, available from:
https://lenovopress.com/lp1287-lenovo-rack-cabinet-reference

For more information, see the list of Product Guides in the Rack cabinets category:
https://lenovopress.com/servers/options/racks

KVM switches and consoles

The following table lists the supported KVM consoles.

Table 77. KVM console
Part number Description
Consoles
4XF7A84188 ThinkSystem 18.5" LCD Console (with US English keyboard)
4XF7A73009 ThinkSystem 18.5" LCD console (with US English keyboard)
17238BX 1U 18.5" Standard Console (without keyboard - see the next table)

The following table lists the keyboards supported with the 1U 18.5" Standard Console (now withdrawn).

Note: These keyboards are not supported with the ThinkSystem 18.5" LCD Console.

Table 78. Keyboards for 1U 18.5" Standard Console
Part number Description
7ZB7A05469 ThinkSystem Keyboard w/ Int.Pointing Device USB - Arabic 253 RoHS v2
7ZB7A05468 ThinkSystem Keyboard w/ Int. Pointing Device USB - Belg/UK 120 RoHS v2
7ZB7A05206 ThinkSystem Keyboard w/ Int. Pointing Device USB - Czech 489 RoHS v2
7ZB7A05207 ThinkSystem Keyboard w/ Int. Pointing Device USB - Danish 159 RoHS v2
7ZB7A05208 ThinkSystem Keyboard w/ Int. Pointing Device USB - Dutch 143 RoHS v2
7ZB7A05210 ThinkSystem Keyboard w/ Int. Pointing Device USB - Fr/Canada 445 RoHS v2
7ZB7A05209 ThinkSystem Keyboard w/ Int. Pointing Device USB - French 189 RoHS v2
7ZB7A05211 ThinkSystem Keyboard w/ Int. Pointing Device USB - German 129 RoHS v2
7ZB7A05212 ThinkSystem Keyboard w/ Int. Pointing Device USB - Greek 219 RoHS v2
7ZB7A05213 ThinkSystem Keyboard w/ Int. Pointing Device USB - Hebrew 212 RoHS v2
7ZB7A05214 ThinkSystem Keyboard w/ Int. Pointing Device USB - Hungarian 208 RoHS v2
7ZB7A05215 ThinkSystem Keyboard w/ Int. Pointing Device USB - Italian 141 RoHS v2
7ZB7A05216 ThinkSystem Keyboard w/ Int. Pointing Device USB - Japanese 194 RoHS v2
7ZB7A05217 ThinkSystem Keyboard w/ Int. Pointing Device USB - Korean 413 RoHS v2
7ZB7A05218 ThinkSystem Keyboard w/ Int. Pointing Device USB - LA Span 171 RoHS v2
7ZB7A05219 ThinkSystem Keyboard w/ Int. Pointing Device USB - Norwegian 155 RoHS v2
7ZB7A05220 ThinkSystem Keyboard w/ Int. Pointing Device USB - Polish 214 RoHS v2
7ZB7A05221 ThinkSystem Keyboard w/ Int. Pointing Device USB - Portugese 163 RoHS v2
7ZB7A05222 ThinkSystem Keyboard w/ Int. Pointing Device USB - Russian 441 RoHS v2
7ZB7A05223 ThinkSystem Keyboard w/ Int. Pointing Device USB - Slovak 245 RoHS v2
7ZB7A05231 ThinkSystem Keyboard w/ Int. Pointing Device USB - Slovenian 234 RoHS v2
7ZB7A05224 ThinkSystem Keyboard w/ Int. Pointing Device USB - Spanish 172 RoHS v2
7ZB7A05225 ThinkSystem Keyboard w/ Int. Pointing Device USB - Swed/Finn 153 RoHS v2
7ZB7A05226 ThinkSystem Keyboard w/ Int. Pointing Device USB - Swiss F/G 150 RoHS v2
7ZB7A05227 ThinkSystem Keyboard w/ Int. Pointing Device USB - Thai 191 RoHS v2
7ZB7A05467 ThinkSystem Keyboard with Int. Pointing Device USB - Trad Chinese/US 467 RoHS v2
7ZB7A05228 ThinkSystem Keyboard w/ Int. Pointing Device USB - Turkish 179 RoHS v2
7ZB7A05229 ThinkSystem Keyboard w/ Int. Pointing Device USB - UK Eng 166 RoHS v2
7ZB7A05470 ThinkSystem Keyboard w/ Int. Pointing Device USB - US Eng 103P RoHS v2
7ZB7A05230 ThinkSystem Keyboard w/ Int. Pointing Device USB - US Euro 103P RoHS v2

The following table lists the available KVM switches and the options that are supported with them.

Table 79. KVM switches and options
Part number Description
KVM Console switches
1754D1T ThinkSystem Digital 2x1x16 KVM Switch (DVI video output port)
1754A1T ThinkSystem Analog 1x8 KVM Switch (DVI video output port)
1754D2X Global 4x2x32 Console Manager (GCM32)
1754D1X Global 2x2x16 Console Manager (GCM16)
1754A2X Local 2x16 Console Manager (LCM16)
1754A1X Local 1x8 Console Manager (LCM8)
Cables for ThinkSystem Digital and Analog KVM Console switches
4X97A11108 ThinkSystem VGA to DVI Conversion Cable
4X97A11109 ThinkSystem Single-USB Conversion Cable for Digital KVM
4X97A11107 ThinkSystem Dual-USB Conversion Cable for Digital KVM
4X97A11106 ThinkSystem USB Conversion Cable for Analog KVM
Cables for GCM and LCM Console switches
43V6147 Single Cable USB Conversion Option (UCO)
39M2895 USB Conversion Option Pack
46M5383 Virtual Media Conversion Option Gen2 (VCO2)
46M5382 Serial Conversion Option (SCO)

For more information, see the list of Product Guides in the KVM Switches and Consoles category:
http://lenovopress.com/servers/options/kvm

Power distribution units

The following table lists the power distribution units (PDUs) that are offered by Lenovo.

Table 80. Power distribution units
Part
number
Feature
code
Description
ANZ
ASEAN
Brazil
EET
MEA
RUCIS
WE
HTK
INDIA
JAPAN
LA
NA
PRC
0U Basic PDUs
4PU7A93176 C0QH 0U 36 C13 and 6 C19 Basic 32A 1 Phase PDU v2 Y Y Y Y Y Y Y Y Y N Y Y Y
4PU7A93169 C0DA 0U 36 C13 and 6 C19 Basic 32A 1 Phase PDU Y Y Y Y Y Y Y Y Y N Y Y Y
4PU7A93177 C0QJ 0U 24 C13/C15 and 24 C13/C15/C19 Basic 32A 3 Phase WYE PDU v2 Y Y Y Y Y Y Y Y Y Y Y Y Y
4PU7A93170 C0D9 0U 24 C13/C15 and 24 C13/C15/C19 Basic 32A 3 Phase WYE PDU Y Y Y Y Y Y Y Y Y N Y Y Y
00YJ776 ATZY 0U 36 C13/6 C19 24A 1 Phase PDU N Y Y N N N N N N Y Y Y N
00YJ779 ATZX 0U 21 C13/12 C19 48A 3 Phase PDU N N Y N N N Y N N Y Y Y N
00YJ777 ATZZ 0U 36 C13/6 C19 32A 1 Phase PDU Y Y N Y Y Y Y Y Y N N Y Y
00YJ778 AU00 0U 21 C13/12 C19 32A 3 Phase PDU Y Y N Y Y Y Y Y Y N N Y Y
0U Switched and Monitored PDUs
4PU7A93181 C0QN 0U 21 C13/C15 and 21 C13/C15/C19 Switched and Monitored 48A 3 Phase Delta PDU v2 (60A derated) N Y N N N N N Y N Y N Y N
4PU7A93174 C0D5 0U 21 C13/C15 and 21 C13/C15/C19 Switched and Monitored 48A 3 Phase Delta PDU (60A derated) N Y N Y N N Y Y N N N Y N
4PU7A93178 C0QK 0U 20 C13 and 4 C19 Switched and Monitored 32A 1 Phase PDU v2 Y Y Y Y Y Y Y Y Y N Y Y Y
4PU7A93171 C0D8 0U 20 C13 and 4 C19 Switched and Monitored 32A 1 Phase PDU Y Y Y Y Y Y Y Y Y N Y Y Y
4PU7A93182 C0QP 0U 18 C13/C15 and 18 C13/C15/C19 Switched and Monitored 63A 3 Phase WYE PDU v2 Y Y Y Y Y Y Y Y Y Y Y Y Y
4PU7A93175 C0CS 0U 18 C13/C15 and 18 C13/C15/C19 Switched and Monitored 63A 3 Phase WYE PDU Y Y Y Y Y Y Y Y Y N Y Y Y
4PU7A93180 C0QM 0U 18 C13/C15 and 18 C13/C15/C19 Switched and Monitored 32A 3 Phase WYE PDU v2 Y Y Y Y Y Y Y Y Y Y Y Y Y
4PU7A93173 C0D6 0U 18 C13/C15 and 18 C13/C15/C19 Switched and Monitored 32A 3 Phase WYE PDU Y Y Y Y Y Y Y Y Y N Y Y Y
4PU7A93179 C0QL 0U 16 C13/C15 and 16 C13/C15/C19 Switched and Monitored 24A 1 Phase PDU v2 (30A derated) N Y N N N N N Y N Y N Y N
4PU7A93172 C0D7 0U 16 C13/C15 and 16 C13/C15/C19 Switched and Monitored 24A 1 Phase PDU(30A derated) N Y N Y N N Y Y N N N Y N
00YJ783 AU04 0U 12 C13/12 C19 Switched and Monitored 48A 3 Phase PDU N N Y N N N Y N N Y Y Y N
00YJ781 AU03 0U 20 C13/4 C19 Switched and Monitored 24A 1 Phase PDU N N Y N Y N Y N N Y Y Y N
00YJ782 AU02 0U 18 C13/6 C19 Switched and Monitored 32A 3 Phase PDU Y Y Y Y Y Y Y Y Y N Y N Y
00YJ780 AU01 0U 20 C13/4 C19 Switched and Monitored 32A 1 Phase PDU Y Y Y Y Y Y Y Y Y N Y N Y
1U Switched and Monitored PDUs
4PU7A90808 C0D4 1U 18 C19/C13 Switched and monitored 48A 3P WYE PDU V2 ETL Y Y Y Y Y Y Y Y Y Y Y Y Y
4PU7A81117 BNDV 1U 18 C19/C13 switched and monitored 48A 3P WYE PDU - ETL N N N N N N N N N N N Y N
4PU7A90809 C0DE 1U 18 C19/C13 Switched and monitored 48A 3P WYE PDU V2 CE N N N N N Y Y N N N N N N
4PU7A81118 BNDW 1U 18 C19/C13 switched and monitored 48A 3P WYE PDU - CE Y Y Y Y Y Y Y Y Y N Y N Y
4PU7A90810 C0DD 1U 18 C19/C13 Switched and monitored 80A 3P Delta PDU V2 Y Y Y Y Y Y Y Y Y Y Y Y Y
4PU7A77467 BLC4 1U 18 C19/C13 Switched and Monitored 80A 3P Delta PDU N N N N N N N N N Y N Y N
4PU7A90811 C0DC 1U 12 C19/C13 Switched and monitored 32A 3P WYE PDU V2 N N N N N Y Y N N N N N N
4PU7A77468 BLC5 1U 12 C19/C13 switched and monitored 32A 3P WYE PDU Y Y Y Y Y Y Y Y Y Y Y Y Y
4PU7A90812 C0DB 1U 12 C19/C13 Switched and monitored 60A 3P Delta PDU V2 N N N N N N N N N Y N N N
4PU7A77469 BLC6 1U 12 C19/C13 switched and monitored 60A 3P Delta PDU N N N N N N N N N N N Y N
46M4002 5896 1U 9 C19/3 C13 Switched and Monitored DPI PDU Y Y Y Y Y Y Y Y Y Y Y Y Y
46M4004 5894 1U 12 C13 Switched and Monitored DPI PDU Y Y Y Y Y Y Y Y Y Y Y Y Y
46M4003 5897 1U 9 C19/3 C13 Switched and Monitored 60A 3 Phase PDU Y Y Y Y Y Y Y Y Y Y Y Y Y
46M4005 5895 1U 12 C13 Switched and Monitored 60A 3 Phase PDU Y Y Y Y Y Y Y Y Y Y Y Y Y
1U Ultra Density Enterprise PDUs (9x IEC 320 C13 + 3x IEC 320 C19 outlets)
71763NU 6051 Ultra Density Enterprise C19/C13 PDU 60A/208V/3PH N N Y N N N N N N Y Y Y N
71762NX 6091 Ultra Density Enterprise C19/C13 PDU Module Y Y Y Y Y Y Y Y Y Y Y Y Y
1U C13 Enterprise PDUs (12x IEC 320 C13 outlets)
39M2816 6030 DPI C13 Enterprise PDU Plus Module (WW) Y Y Y Y Y Y Y Y Y Y Y Y Y
39Y8941 6010 DPI C13 Enterprise PDU Module (WW) Y Y Y Y Y Y Y Y Y Y Y Y Y
1U C19 Enterprise PDUs (6x IEC 320 C19 outlets)
39Y8948 6060 DPI C19 Enterprise PDU Module (WW) Y Y Y Y Y Y Y Y Y Y Y Y Y
39Y8923 6061 DPI Three-phase 60A/208V C19 Enterprise PDU (US) N N Y N N N Y N N N Y Y N
1U Front-end PDUs (3x IEC 320 C19 outlets)
39Y8938 6002 DPI Single-phase 30A/120V Front-end PDU (US) Y Y Y Y Y Y Y Y Y Y Y Y Y
39Y8939 6003 DPI Single-phase 30A/208V Front-end PDU (US) Y Y Y Y Y Y Y Y Y Y Y Y Y
39Y8934 6005 DPI Single-phase 32A/230V Front-end PDU (International) Y Y Y Y Y Y Y Y Y Y Y Y Y
39Y8940 6004 DPI Single-phase 60A/208V Front-end PDU (US) Y N Y Y Y Y Y N N Y Y Y N
39Y8935 6006 DPI Single-phase 63A/230V Front-end PDU (International) Y Y Y Y Y Y Y Y Y Y Y Y Y
1U NEMA PDUs (6x NEMA 5-15R outlets)
39Y8905 5900 DPI 100-127V NEMA PDU Y Y Y Y Y Y Y Y Y Y Y Y Y
Line cords for 1U PDUs that ship without a line cord
40K9611 6504 4.3m, 32A/380-415V, EPDU/IEC 309 3P+N+G 3ph wye (non-US) Line Cord Y Y Y Y Y Y Y Y Y Y Y Y Y
40K9612 6502 4.3m, 32A/230V, EPDU to IEC 309 P+N+G (non-US) Line Cord Y Y Y Y Y Y Y Y Y Y Y Y Y
40K9613 6503 4.3m, 63A/230V, EPDU to IEC 309 P+N+G (non-US) Line Cord Y Y Y Y Y Y Y Y Y Y Y Y Y
40K9614 6500 4.3m, 30A/208V, EPDU to NEMA L6-30P (US) Line Cord Y Y Y Y Y Y Y Y Y Y Y Y Y
40K9615 6501 4.3m, 60A/208V, EPDU to IEC 309 2P+G (US) Line Cord N N Y N N N Y N N Y Y Y N
40K9617 6505 4.3m, 32A/230V, Souriau UTG Female to AS/NZ 3112 (Aus/NZ) Line Cord Y Y Y Y Y Y Y Y Y Y Y Y Y
40K9618 6506 4.3m, 32A/250V, Souriau UTG Female to KSC 8305 (S. Korea) Line Cord Y Y Y Y Y Y Y Y Y Y Y Y Y

For more information, see the Lenovo Press documents in the PDU category:
https://lenovopress.com/servers/options/pdu

Uninterruptible power supply units

The following table lists the uninterruptible power supply (UPS) units that are offered by Lenovo.

Table 81. Uninterruptible power supply units
Part number Description
Rack-mounted or tower UPS units - 100-125VAC
7DD5A001WW RT1.5kVA 2U Rack or Tower UPS-G2 (100-125VAC)
55941AX RT1.5kVA 2U Rack or Tower UPS (100-125VAC)
55942AX RT2.2kVA 2U Rack or Tower UPS (100-125VAC)
7DD5A003WW RT3kVA 2U Rack or Tower UPS-G2 (100-125VAC)
55943AX RT3kVA 2U Rack or Tower UPS (100-125VAC)
Rack-mounted or tower UPS units - 200-240VAC
7DD5A002WW RT1.5kVA 2U Rack or Tower UPS-G2 (200-240VAC)
55941KX RT1.5kVA 2U Rack or Tower UPS (200-240VAC)
55942KX RT2.2kVA 2U Rack or Tower UPS (200-240VAC)
7DD5A005WW RT3kVA 2U Rack or Tower UPS-G2 (200-240VAC)
55943KX RT3kVA 2U Rack or Tower UPS (200-240VAC)
7DD5A007WW RT5kVA 3U Rack or Tower UPS-G2 (200-240VAC)
55945KX RT5kVA 3U Rack or Tower UPS (200-240VAC)
7DD5A008WW RT6kVA 3U Rack or Tower UPS-G2 (200-240VAC)
55946KX RT6kVA 3U Rack or Tower UPS (200-240VAC)
55948KX RT8kVA 6U Rack or Tower UPS (200-240VAC)
7DD5A00AWW RT11kVA 6U Rack or Tower UPS-G2 (200-240VAC)
55949KX RT11kVA 6U Rack or Tower UPS (200-240VAC)
55943KT† ThinkSystem RT3kVA 2U Standard UPS (200-230VAC) (2x C13 10A, 2x GB 10A, 1x C19 16A outlets)
55943LT† ThinkSystem RT3kVA 2U Long Backup UPS (200-230VAC) (2x C13 10A, 2x GB 10A, 1x C19 16A outlets)
55946KT† ThinkSystem RT6kVA 5U UPS (200-230VAC) (2x C13 10A outlets, 1x Terminal Block output)
5594XKT† ThinkSystem RT10kVA 5U UPS (200-230VAC) (2x C13 10A outlets, 1x Terminal Block output)
Rack-mounted or tower UPS units - 380-415VAC
55948PX RT8kVA 6U 3:1 Phase Rack or Tower UPS (380-415VAC)
55949PX RT11kVA 6U 3:1 Phase Rack or Tower UPS (380-415VAC)

† Only available in China and the Asia Pacific market.

For more information, see the list of Product Guides in the UPS category:
https://lenovopress.com/servers/options/ups

Lenovo Financial Services

Why wait to obtain the technology you need now? No payments for 90 days and predictable, low monthly payments make it easy to budget for your Lenovo solution.

  • Flexible

    Our in-depth knowledge of the products, services and various market segments allows us to offer greater flexibility in structures, documentation and end of lease options.

  • 100% Solution Financing

    Financing your entire solution including hardware, software, and services, ensures more predictability in your project planning with fixed, manageable payments and low monthly payments.

  • Device as a Service (DaaS)

    Leverage latest technology to advance your business. Customized solutions aligned to your needs. Flexibility to add equipment to support growth. Protect your technology with Lenovo's Premier Support service.

  • 24/7 Asset management

    Manage your financed solutions with electronic access to your lease documents, payment histories, invoices and asset information.

  • Fair Market Value (FMV) and $1 Purchase Option Leases

    Maximize your purchasing power with our lowest cost option. An FMV lease offers lower monthly payments than loans or lease-to-own financing. Think of an FMV lease as a rental. You have the flexibility at the end of the lease term to return the equipment, continue leasing it, or purchase it for the fair market value. In a $1 Out Purchase Option lease, you own the equipment. It is a good option when you are confident you will use the equipment for an extended period beyond the finance term. Both lease types have merits depending on your needs. We can help you determine which option will best meet your technological and budgetary goals.

Ask your Lenovo Financial Services representative about this promotion and how to submit a credit application. For the majority of credit applicants, we have enough information to deliver an instant decision and send a notification within minutes.

Seller training courses

The following sales training courses are offered for employees and partners (login required). Courses are listed in date order.

  1. Partner Technical Webinar - LenovoPress updates and LPH Demo
    2024-11-13 | 60 minutes | Employees and Partners
    Details
    Partner Technical Webinar - LenovoPress updates and LPH Demo

    in this 60-minute replay, we had 3 topics. First, David Watts, Lenovo Sr Manager LenovoPress, gave an update on LenovoPress and improvements to finding Seller Training Courses (both partner and Lenovo). Next, Ryan Tuttle, Lenovo LETS Solution Architect, gave a demo of Lenovo Partner Hub (LPH) including how to find replays of Partner Webinars in LPL. Finally, Joe Murphy, Lenovo Sr Manager of LETS NA, gave a quick update on the new Stackable Warranty Options in DCSC.

    Published: 2024-11-13
    Length: 60 minutes

    Start the training:
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning

    Course code: 110824
  2. ThinkSystem Rack and Tower Introduction for ISO Client Managers
    2024-10-31 | 20 minutes | Employees Only
    Details
    ThinkSystem Rack and Tower Introduction for ISO Client Managers

    Course Description:
    In this course, you will learn about Lenovo’s Data Center Portfolio, its ThinkSystem Family and the key features of the Rack and Tower servers. It will equip you with foundational knowledge which you can then expand upon by participating in the facilitated session of the curriculum.

    Course Objectives:
    By the end of this course, you should be able to:
    • Identify Lenovo’s main data center brands.
    • Describe the key components of the ThinkSystem Family servers.
    • Differentiate between the Rack and Tower servers of the ThinkSystem Family.
    • Understand the value Rack and Tower servers can provide to customers.

    Published: 2024-10-31
    Length: 20 minutes

    Start the training:
    Employee link: Grow@Lenovo

    Course code: DSRTO101
  3. Virtual Facilitated Session - ThinkSystem Rack and Tower Primer for ISO Client Managers
    2024-10-31 | 90 minutes | Employees Only
    Details
    Virtual Facilitated Session - ThinkSystem Rack and Tower Primer for ISO Client Managers

    In this instructor-led Virtual Facilitated Session, ISO Client Managers will be able to build on the knowledge gained in Module 1 (eLearning) of the ThinkSystem Rack and Tower Server Primer for ISO Client Managers curriculum.

    <p style="font-weight:bold"> You will receive the invite to this session via email. </p> Places are subject to availability.

    <p style="color:red;"> IMPORTANT! </p> Module 1 (eLearning) must be completed to be eligible to participate in the session.

    Published: 2024-10-31
    Length: 90 minutes

    Start the training:
    Employee link: Grow@Lenovo

    Course code: DSRTO102
  4. Partner Technical Webinar - OneIQ
    2024-07-15 | 60 minutes | Employees and Partners
    Details
    Partner Technical Webinar - OneIQ

    In this 60-minute replay, Peter Grant, Field CTO for OneIQ, reviewed and demo’d the capabilities of OneIQ including collecting data and analyzing. Additionally, Peter and the team discussed how specific partners (those with NA Channel SA coverage) will get direct access to OneIQ and other partners can get access to OneIQ via Distribution or the NA LETS team.

    Published: 2024-07-15
    Length: 60 minutes

    Start the training:
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning

    Course code: 071224
  5. SAP Webinar for Lenovo Sellers: Lenovo Portfolio Update for SAP Landscapes
    2024-06-04 | 60 minutes | Employees Only
    Details
    SAP Webinar for Lenovo Sellers: Lenovo Portfolio Update for SAP Landscapes

    Join Mark Kelly, Advisory IT Architect with the Lenovo Global SAP Center of Competence as he discusses:
    • Challenges in the SAP environment
    • Lenovo On-premise Solutions for SAP
    • Lenovo support resources for SAP solutions

    Published: 2024-06-04
    Length: 60 minutes

    Start the training:
    Employee link: Grow@Lenovo

    Course code: DSAPF101
  6. Lenovo Data Center Product Portfolio
    2024-05-29 | 20 minutes | Employees and Partners
    Details
    Lenovo Data Center Product Portfolio

    This course introduces the Lenovo data center portfolio, and covers servers, storage, storage networking, and software-defined infrastructure products. After completing this course about Lenovo data center products, you will be able to identify product types within each data center family, describe Lenovo innovations that this product family or category uses, and recognize when a specific product should be selected.

    Published: 2024-05-29
    Length: 20 minutes

    Start the training:
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning

    Course code: SXXW1110r7
  7. VTT Cloud Architecture: NVIDIA Using Cloud for GPUs and AI
    2024-05-22 | 60 minutes | Employees Only
    Details
    VTT Cloud Architecture: NVIDIA Using Cloud for GPUs and AI

    Join JD Dupont, NVIDIA Head of Americas Sales, Lenovo partnership and Veer Mehta, NVIDIA Solution Architect on an interactive discussion about cloud to edge, designing cloud Solutions with NVIDIA GPUs and minimizing private\hybrid cloud OPEX with GPUs. Discover how you can use what is done at big public cloud providers for your customers. We will also walk through use cases and see a demo you can use to help your customers.

    Published: 2024-05-22
    Length: 60 minutes

    Start the training:
    Employee link: Grow@Lenovo

    Course code: DVCLD212
  8. Partner Technical Webinar - ISG Portfolio Update
    2024-04-15 | 60 minutes | Employees and Partners
    Details
    Partner Technical Webinar - ISG Portfolio Update

    In this 60-minute replay, Mark Bica, NA ISG Server Product Manager reviewed the Lenovo ISG portfolio. He covered new editions such as the SR680a \ SR685a, dense servers, and options that are strategic for any workload.

    Published: 2024-04-15
    Length: 60 minutes

    Start the training:
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning

    Course code: 041224
  9. Partner Technical Webinar - StorMagic
    2024-03-19 | 60 minutes | Employees and Partners
    Details
    Partner Technical Webinar - StorMagic

    March 08, 2024 – In this 60-minute replay, Stuart Campbell and Wes Ganeko of StorMagic joined us and provided an overview of StorMagic on Lenovo. They also demonstrated the interface while sharing some interesting use cases.

    Published: 2024-03-19
    Length: 60 minutes

    Start the training:
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning

    Course code: 030824
  10. Family Portfolio: Storage Controller Options
    2024-01-23 | 25 minutes | Employees and Partners
    Details
    Family Portfolio: Storage Controller Options

    This course covers the storage controller options available for use in Lenovo servers. The classes of storage controller are discussed, along with a discussion of where they are used, and which to choose.

    After completing this course, you will be able to:
    • Describe the classes of storage controllers
    • Discuss where each controller class is used
    • Describe the available options in each controller class

    Published: 2024-01-23
    Length: 25 minutes

    Start the training:
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning

    Course code: SXXW1111
  11. Lenovo-Intel Sustainable Solutions QH
    2024-01-22 | 10 minutes | Employees and Partners
    Details
    Lenovo-Intel Sustainable Solutions QH

    This Quick Hit explains how Lenovo and Intel are committed to sustainability, and introduces the Lenovo-Intel joint sustainability campaign. You will learn how to use this campaign to show customers what that level of commitment entails, how to use the campaign's unsolicited proposal approach, and how to use the campaign as a conversation starter which may lead to increased sales.

    Published: 2024-01-22
    Length: 10 minutes

    Start the training:
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning

    Course code: SXXW2524a
  12. Family Introduction: Rack and Tower
    2024-01-19 | 11 minutes | Employees and Partners
    Details
    Family Introduction: Rack and Tower

    This course is designed to give Lenovo sales and partner representatives a foundation on the characteristics of the rack and tower server family. As an introduction to the family, this course also includes positioning, when to use a product, and keywords a client may use when discussing a rack product.

    Course Objectives:
    • Family Characteristics
    • Priority Positioning
    • Product Usage
    • Keywords and Phrases

    Published: 2024-01-19
    Length: 11 minutes

    Start the training:
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning

    Course code: SXXW1100r3
  13. FY24Q3 Intel Servers Update
    2023-12-11 | 15 minutes | Employees and Partners
    Details
    FY24Q3 Intel Servers Update

    This update is designed to help you discuss the features and customer benefits of Lenovo servers that use the 5th Gen Intel® Xeon® processors. Lenovo has also introduced a new server, the ThinkSystem SD650-N V3, which expands the supercomputer server family. Reasons to call your customer and talk about refreshing their infrastructure are also included as a guideline.

    Published: 2023-12-11
    Length: 15 minutes

    Start the training:
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning

    Course code: SXXW2522a
  14. Partner Technical Webinar - Cloudian - Ransomware
    2023-10-12 | 60 minutes | Employees and Partners
    Details
    Partner Technical Webinar - Cloudian - Ransomware

    In this 60-minute replay, Tim O’Neal, Eric Craig, and Charlii Collins of Cloudian discuss how Cloudian protects from Ransomware paired with VEEAM, Commvault, or Rubrik.

    Published: 2023-10-12
    Length: 60 minutes

    Start the training:
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning

    Course code: 100623
  15. Partner Technical Webinar - Data Center Limits and ISG TAA Compliance
    2023-05-16 | 60 minutes | Employees and Partners
    Details
    Partner Technical Webinar - Data Center Limits and ISG TAA Compliance

    In this 60-minute replay, we had two topics. First Vinod Kamath, Lenovo Distinguished Engineer for Data Center Cooling presented on the Systems Configuration and Data Center Ambient Limits. Second, Shama Patari, Lenovo Trade Council, and Glenn Johnson, Lenovo Principal Engineer for Supply Chain presented on ISG TAA Compliance.

    Published: 2023-05-16
    Length: 60 minutes

    Start the training:
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning

    Course code: 051223
  16. Family Portfolio: Edge Solutions
    2022-12-06 | 10 minutes | Employees and Partners
    Details
    Family Portfolio: Edge Solutions

    This course describes the Lenovo edge solutions. Edge servers, such as the Lenovo ThinkSystem SE350 and ThinkEdge SE450, are used at the edge of an IoT environment, and may be part of an edge solution. Solutions such as those using software from Scale Computing typically use more traditional Lenovo servers.
    After completing this course, you will be able to list the edge solutions in the Lenovo portfolio, describe the features of each solution and determine which solution is best suited to a specific environment.

    Published: 2022-12-06
    Length: 10 minutes

    Start the training:
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning

    Course code: SXXW1108r4
  17. Lenovo Sustainable Computing
    2022-09-16 | 4 minutes | Employees and Partners
    Details
    Lenovo Sustainable Computing

    This Quick Hit describes the Lenovo sustainable computing program, and the many ways in which Lenovo strives to respect and protect the environment.

    Published: 2022-09-16
    Length: 4 minutes

    Start the training:
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning

    Course code: SXXW2504a

1-10 of 17 courses.

Related product families

Product families related to this document are the following:

Trademarks

Lenovo and the Lenovo logo are trademarks or registered trademarks of Lenovo in the United States, other countries, or both. A current list of Lenovo trademarks is available on the Web at https://www.lenovo.com/us/en/legal/copytrade/.

The following terms are trademarks of Lenovo in the United States, other countries, or both:
Lenovo®
AnyBay®
System x®
ThinkAgile®
ThinkServer®
ThinkSystem®
XClarity®

The following terms are trademarks of other companies:

AMD, AMD Radeon™, Alveo™, Radeon Instinct™, Radeon™, and Xilinx are trademarks of Advanced Micro Devices, Inc.

Intel®, Intel Optane®, and Xeon® are trademarks of Intel Corporation or its subsidiaries.

Linux® is the trademark of Linus Torvalds in the U.S. and other countries.

Microsoft®, Hyper-V®, PowerShell, Windows PowerShell®, Windows Server®, and Windows® are trademarks of Microsoft Corporation in the United States, other countries, or both.

SPECpower® is a trademark of the Standard Performance Evaluation Corporation (SPEC).

Other company, product, or service names may be trademarks or service marks of others.