Abstract
Lenovo ThinkAgile VX Certified Nodes are designed for deploying industry-leading Hyper-Converged Infrastructure (HCI) software from VMware on Lenovo enterprise platforms that feature the Intel Xeon processors. They deliver fully validated and integrated Lenovo hardware and firmware that is certified with VMware software and preloaded with the VMware ESXi hypervisor. VMware offers a unique, software-defined approach to hyper convergence, leveraging the hypervisor to deliver compute, storage and management in a tightly integrated software stack.
This product guide provides essential technical and pre-sales information on the Lenovo ThinkAgile VX 1SE Certified Node, its key features and specifications, components and options, and configuration guidelines.
This guide is intended for technical specialists, sales specialists, sales engineers, IT architects, and other IT professionals who want to learn more about the ThinkAgile VX 1SE Certified Node and consider its use in IT solutions.
Introduction
Lenovo ThinkAgile VX Certified Nodes are designed for deploying industry-leading Hyper-Converged Infrastructure (HCI) software from VMware on Lenovo enterprise platforms that feature the Intel Xeon processors. They deliver fully validated and integrated Lenovo hardware and firmware that is certified with VMware software and preloaded with the VMware ESXi hypervisor. VMware offers a unique, software-defined approach to hyper convergence, leveraging the hypervisor to deliver compute, storage and management in a tightly integrated software stack.
The ThinkAgile VX 1SE Certified Node is a 1U rack-mount system that supports one processor, up to 64 GB of TruDDR4 memory with up to 2666 MHz memory speeds, 4x 3.5-inch or up to 10x 2.5-inch SAS/SATA drive bays with an extensive choice of SATA SSDs and SAS HDDs, and flexible network connectivity options with 1/10 GbE RJ-45, 10 GbE SFP+, and 10/25 GbE SFP28 ports.
The ThinkAgile VX 1SE Certified Nodes are engineered for light to medium workloads (business applications and VDI) and optimized for remote office and branch office (ROBO) environments.
The ThinkAgile VX 1SE Certified Nodes are shown in the following figure.
Figure 1. Lenovo ThinkAgile VX 1SE Certified Node with 4x LFF (top) or 10x SFF (bottom) drive bays
Did you know?
The ThinkAgile VX Certified Nodes are built on industry-leading Lenovo ThinkSystem servers that feature enterprise-class reliability, management, and security.
The ThinkAgile VX Certified Nodes deliver fully validated and integrated hardware and firmware that is certified with VMware software.
Key features
The ThinkAgile VX Certified Nodes offer the following key features:
- Offer quick and convenient path to implement a hyperconverged solution powered by VMware vSAN with a wide range of selection options for processors, memory, storage, and network connectivity.
- Built on proven and reliable Lenovo ThinkSystem servers featuring Intel Xeon Processor Family that provide compute power for a variety of workloads and applications.
- Meet various workload demands with cost-efficient hybrid or performance-optimized all-flash storage configurations.
- Deliver fully validated and integrated hardware and firmware that is certified with VMware software.
- Preloaded with the VMware ESXi hypervisor and ready for out-of-box deployment (software licenses are not included).
- Provide flexibility in using the existing VMware enterprise license agreements or purchasing new software licenses and support contracts from VMware or Lenovo.
- Offer optional Lenovo deployment services to get customers up and running quickly.
The VMware software running on ThinkAgile VX Certified Nodes delivers the following key features:
- Distributed architecture that allows "pay-as-you-grow", non-disruptive scaling by adding new nodes to the cluster (scale-out) to increase capacity and performance.
- Advanced capacity management, including deduplication, compression, and erasure coding (RAID 5/6), which helps deliver greater storage utilization with lower storage capacity and costs.
- Automation of VM storage provisioning and control of storage service levels (capacity, performance, availability) with VM-centric policies to load balance storage resources.
- Native HCI security solution with two-factor authentication (SecurID and CAC) and data-at-rest encryption that does not require self-encrypting drives (SEDs).
- Stretched cluster with local and site failure protection between two geographically dispersed sites for higher level of availability with near zero downtime.
- Centralized management with provisioning, administering, and monitoring virtual resources across multiple hosts and clusters from a centralized interface.
- Rapid workload provisioning, simplified data center operations, increased business efficiency, and decreased CAPEX and OPEX costs.
- VM and data protection with agent-less, image-level virtual machine backups and application-aware protection for business-critical Microsoft applications (Exchange, SQL Server, SharePoint) along with WAN-efficient, encrypted backup data replication.
- Reduced unplanned downtime and virtually eliminated planned downtime for server and storage maintenance with live workload migration, high availability, and fault tolerance.
- Enhanced application performance and availability with resource management, load balancing, and access prioritization.
- Intelligent operations management and automation to proactively monitor and manage compute, storage, and networking resources, identify performance bottlenecks, and re-balance workloads by leveraging predictive analytics.
- Capacity planning and optimization guidance to address future needs with performance trends, projections and extended forecasts.
- Managing remote offices and branch offices with rapid provisioning of servers through virtualization, minimization of host configuration drift, and enhanced visibility into regulatory compliance, across multiple sites.
Components and connectors
The following figure shows the front of the ThinkAgile VX 1SE Certified Node with four 3.5-inch drive bays.
Figure 2. Front view of the ThinkAgile VX 1SE Certified Node: 4x 3.5-inch drive bays
The following figure shows the front of the ThinkAgile VX 1SE Certified Node with eight 2.5-inch drive bays.
Figure 3. Front view of the ThinkAgile VX 1SE Certified Node: 8x 2.5-inch drive bays
The following figure shows the front of the ThinkAgile VX 1SE Certified Node with ten 2.5-inch drive bays.
Figure 4. Front view of the VX 1SE Certified Node: 10x 2.5-inch drive bays
The front of the ThinkAgile VX 1SE Certified Node includes the following components:
- Drive bays:
- 4x 3.5-inch (Large Form Factor [LFF]) SAS/SATA hot-swap; or
- 8x 2.5-inch (Small Form Factor [SFF]) SAS/SATA hot-swap; or
- 10x 2.5-inch SAS/SATA hot-swap drive bays.
- One VGA port (optional)
- One USB 2.0 port with XClarity Controller access
- One USB 3.1 Gen 1 port
- A Power button
- Status LEDs
The following figure shows the rear of the ThinkAgile VX 1SE Certified Node.
Figure 5. Rear view of the ThinkAgile VX 1SE Certified Node
The rear of the ThinkAgile VX 1SE Certified Node includes the following components:
- Up to two PCIe expansion slots (depending on the riser cards selected).
- One 1 GbE port for XClarity Controller.
- One RS-232 serial port.
- One VGA port.
- Two 1 GbE data network ports.
- Two USB 3.1 Gen 2 ports.
- Power supplies
- Up to two hot-swap power supplies; or
- One fixed power supply.
System specifications
The following table lists the system specifications of the ThinkAgile VX 1SE Certified Node.
Attribute | Specification |
---|---|
Form factor | 1U Rack-mount. |
Processor | One Intel Xeon E processor. |
Chipset | Intel C246. |
Memory | 4 DIMM sockets (two memory channels with two DIMMs per channel). Support for ECC UDIMMs. Memory speed up to 2666 MHz. |
Memory capacity | Up to 64 GB (4x 16 GB UDIMMs). |
Memory protection | Error correction code (ECC). |
Drive bays |
|
Drive capacities |
|
Storage controller |
|
Network interfaces |
|
Boot drive | 1x M.2 non-hot-swap SSD up to 480 GB. |
I/O expansion slots | Up to three slots. Slot 4 is the fixed slot on the system planar, and the remaining slots depend on the riser cards installed. The slots are as follows:
|
Ports |
|
Cooling | Four non-hot-swap system fans. |
Power supply | One fixed 300 W Gold, or up to two redundant hot-swap 450 W Platinum AC power supplies. |
Video | Matrox G200 with 16 MB memory integrated into the XClarity Controller. Maximum resolution is 1920x1200 at 60 Hz with 32 bits per pixel. |
Hot-swap parts | Drives and power supplies (select models). |
Systems management | Lenovo XClarity Controller (XCC) Standard, Advanced, or Enterprise (Pilot 4 chip), proactive platform alerts, Lenovo XClarity Administrator with Integrator for VMware vCenter (optional), Lenovo XClarity Energy Manager (optional). |
Security features | Power-on password, administrator's password, secure firmware updates, Trusted Platform Module (TPM) 1.2 or 2.0 (configurable UEFI setting). Optional lockable front bezel. |
Software | Software licenses that can be purchased from Lenovo or provided by the customer:
|
Hypervisors | VMware ESXi 6.5 U2, 6.5 U3, 6.7 U2, or 6.7 U3 (factory preload). |
Warranty and support | Three-, four-, or five-year customer-replaceable unit and onsite limited warranty with selectable service levels: 9x5 coverage with next business day (NBD) parts delivered (base warranty), 9x5 coverage with NBD onsite response (Foundation Service), 24x7 coverage with 4-hour onsite response or 24-hour committed repair (select areas) (Essential Service), or 24x7 coverage with 2-hour onsite response or 6-hour committed repair (select areas) (Advanced Service). Also available are 1-year and 2-year post-warranty extensions, YourDrive YourData, and Enterprise Software Support. |
Software maintenance | One-, three-, or five-year software support and subscription is included with the VMware software licenses available from Lenovo (optional). |
Dimensions | Height: 43 mm (1.7 in.), width: 434 mm (17.1 in.), depth: 498 mm (19.6 in.). |
Weight | Maximum configuration: 12.3 kg (27.1 lb). |
Factory-integrated models
Factory-integrated models of the ThinkAgile VX Certified Nodes are configured by using the Lenovo Data Center Solution Configurator (DCSC):
http://dcsc.lenovo.com
During the configuration process, you are selecting one of the Configure-to-Order (CTO) base models first, and then you are selecting components (processors, memory, drives, network adapters, power supplies, and software) for that model.
Note: You are required to engage a Lenovo representative in the project that includes the ThinkAgile VX Certified Nodes.
The following table lists the CTO base models of the ThinkAgile VX 1SE Certified Nodes.
Description | Machine Type/Model |
---|---|
ThinkAgile VX 1SE Certified Node | 7Z58CTO2WW |
The following table lists the available chassis selection options for the VX 1SE Certified Nodes.
Description | Feature code |
---|---|
ThinkAgile VX 1SE 2.5" Chassis | B5N4 |
ThinkAgile VX 1SE 3.5" Chassis | B5N5 |
The ThinkAgile VX 1SE Certified Nodes ship with the following items:
- Electronic Publications Flyer
- Tool-less Rail Kit (if selected)
- One or two customer-configured power cables (if selected)
Processors
The ThinkAgile VX 1SE Certified Node supports one Intel Xeon E Processor. The following table lists the processors that are available for selection.
Description | Feature code |
---|---|
Intel Xeon E-2126G 6C 80W 3.3GHz Processor | B351 |
Intel Xeon E-2136 6C 80W 3.3GHz Processor | B34Z |
Intel Xeon E-2146G 6C 80W 3.5GHz Processor | B34X |
Intel Xeon E-2176G 6C 80W 3.7GHz Processor | B34V |
Intel Xeon E-2186G 6C 95W 3.8GHz Processor | B34U |
The following table lists the specifications of the processors for the certified nodes.
CPU model |
Core frequency (Base / TB Max) |
Number of cores / threads |
Cache | Max DDR4 frequency |
Max memory capacity |
Bus speed |
TDP | ECC | HT | TB | VT-x | VT-d | SGX |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
E-2126G | 3.30 / 4.50 GHz | 6 / 6 | 12 MB | 2666 MHz | 64 GB | 8 GT/s | 80 W | Yes | No | Yes | Yes | Yes | No |
E-2136 | 3.30 / 4.50 GHz | 6 / 12 | 12 MB | 2666 MHz | 64 GB | 8 GT/s | 80 W | Yes | Yes | Yes | Yes | Yes | No |
E-2146G | 3.50 / 4.50 GHz | 6 / 12 | 12 MB | 2666 MHz | 64 GB | 8 GT/s | 80 W | Yes | Yes | Yes | Yes | Yes | No |
E-2176G | 3.70 / 4.70 GHz | 6 / 12 | 12 MB | 2666 MHz | 64 GB | 8 GT/s | 80 W | Yes | Yes | Yes | Yes | Yes | Yes |
E-2186G | 3.80 / 4.70 GHz | 6 / 12 | 12 MB | 2666 MHz | 64 GB | 8 GT/s | 95 W | Yes | Yes | Yes | Yes | Yes | Yes |
Memory
The ThinkAgile VX 1SE Certified Node supports up to four TruDDR4 memory UDIMMs with ECC protection. The processor has two memory channels with two DIMMs per channel.
Lenovo TruDDR4 memory uses the highest-quality components sourced from Tier 1 DRAM suppliers and only memory that meets strict requirements is selected. It is compatibility tested and tuned to maximize performance and reliability.
The following rules apply when selecting the memory configuration:
- The certified node supports memory configurations with 2, 3, or 4 UDIMMs.
- All DIMMs in the certified node operate at the same speed of up to 2666 MHz.
Note: Maximum memory speed can be achieved when Max performance mode is enabled in UEFI. - The certified node supports up to 64 GB of memory.
The following table lists the memory options that are available for selection for the ThinkAgile VX 1SE Certified Node.
Description | Part number | Feature code | Quantity |
---|---|---|---|
ThinkSystem 16GB TruDDR4 2666MHz (2Rx8, 1.2V) ECC UDIMM | 4ZC7A08699 | B35K | 2, 3, 4 |
Internal storage
The ThinkAgile VX 1SE Certified Node supports the following internal drive bay configurations to provide storage capacity:
- 4x 3.5-inch LFF SAS/SATA hot-swap drive bays.
- 8x 2.5-inch SFF SAS/SATA hot-swap drive bays.
- 10x 2.5-inch SFF SAS/SATA hot-swap drive bays.
The following table lists the internal drive backplanes that are available for selection for the VX 1SE Certified Node.
Description | Feature code | Quantity |
---|---|---|
ThinkSystem SR250 3.5" HS SATA/SAS 4-Bay Backplane | B412 | 1 |
ThinkSystem SR250 2.5" HS SATA/SAS 8-Bay Backplane | B413 | 1 |
ThinkSystem SR250 2.5" HS AnyBay 10-Bay Backplane | B414 | 1 |
Configuration note: One drive backplane is required for selection.
The following table lists M.2 drive selection options for the hypervisor boot volume.
Description | Feature code | Quantity |
---|---|---|
ThinkSystem M.2 128GB SATA 6Gbps Non-Hot-Swap SSD | AUUV | 1 |
ThinkSystem M.2 5100 240GB SATA 6Gbps Non-Hot Swap SSD | B5S4 | 1 |
ThinkSystem M.2 5300 240GB SATA 6Gbps Non-Hot Swap SSD | B8HS | 1 |
ThinkSystem M.2 5100 480GB SATA 6Gbps Non-Hot-Swap SSD | B11V | 1 |
ThinkSystem M.2 5300 480GB SATA 6Gbps Non-Hot Swap SSD | B919 | 1 |
Configuration note: One M.2 SATA SSD is required for selection.
The following table lists the storage controllers for internal storage of the VX 1SE Certified Node.
Description | Feature code | Quantity | I/O slots supported |
---|---|---|---|
ThinkSystem 430-8i SAS/SATA 12Gb HBA (non-RAID) | AUNL | 1 | 2, 4 |
ThinkSystem 430-16i SAS/SATA 12Gb HBA (non-RAID) | AUNM | 1 | 2, 4 |
Configuration notes:
- One SAS HBA for internal storage is required for selection.
- SAS HBAs are supported in the following PCIe slots:
- PCIe slot 2 on the PCIe x8/x8 Riser Card (feature code B418):
- No additional PCIe adapters are installed.
- One additional PCIe adapter is installed in the PCIe slot 1.
- PCIe slot 4 on the system board:
- Two additional PCIe adapters are installed in the PCIe slots 1 and 2.
- The PCIe x16 Riser Card (feature code B417) is installed.
- PCIe slot 2 on the PCIe x8/x8 Riser Card (feature code B418):
The following table lists supported internal storage configurations with the SAS/SATA and AnyBay backplanes.
Drive bay configuration | Backplane and cable type and quantity | Storage controller quantity and type* | |||
---|---|---|---|---|---|
4x 3.5" HS BP (B412)
|
8x 2.5" HS BP (B413)
|
10x 2.5" HS BP (B414)
|
3.5"/2.5" HS x4 Cable HW (B415)
|
||
3.5" chassis (Feature code B5N5) | |||||
4x 3.5-in. SAS/SATA hot-swap | 1 | 0 | 0 | 1 | 1x 430-8i/16i HBA (4) |
2.5" chassis (Feature code B5N4) | |||||
8x 2.5-in. SAS/SATA hot-swap | 0 | 1 | 0 | 2 | 1x 430-8i/16i HBA (8) |
10x 2.5-in. SAS/SATA hot-swap | 0 | 0 | 1 | 3 | 1x 430-16i HBA (10) |
* The number in brackets (x) specifies the quantity of drive bays connected to each of the controllers.
Drives for internal storage
The following tables list the drive selection options for the ThinkAgile VX 1SE Certified Node.
Description | Part number | Feature code |
Maximum quantity
|
Cache
|
Capacity
|
Uncategorized
|
---|---|---|---|---|---|---|
2.5-inch hot-swap HDDs - 12 Gbps SAS | ||||||
ThinkSystem 2.5" 900GB 10K SAS 12Gb Hot Swap 512n HDD | 7XB7A00026 | AUM0 | 10 | N | Y | Y |
ThinkSystem 2.5" 900GB 15K SAS 12Gb Hot Swap 512e HDD | 7XB7A00023 | AULX | 10 | N | Y | Y |
ThinkSystem 2.5" 1.2TB 10K SAS 12Gb Hot Swap 512n HDD | 7XB7A00027 | AUM1 | 10 | N | Y | Y |
ThinkSystem 2.5" 1.8TB 10K SAS 12Gb Hot Swap 512e HDD | 7XB7A00028 | AUM2 | 10 | N | Y | Y |
ThinkSystem 2.5" 2.4TB 10K SAS 12Gb Hot Swap 512e HDD | 7XB7A00069 | B0YS | 10 | N | Y | Y |
2.5-inch hot-swap HDDs - 12 Gbps NL SAS | ||||||
ThinkSystem 2.5" 1TB 7.2K SAS 12Gb Hot Swap 512n HDD | 7XB7A00034 | AUM6 | 10 | N | N | Y |
ThinkSystem 2.5" 2TB 7.2K SAS 12Gb Hot Swap 512n HDD | 7XB7A00035 | AUM7 | 10 | N | N | Y |
2.5-inch hot-swap SSDs - 5200 Mainstream 6 Gbps SATA | ||||||
ThinkSystem 2.5" 5200 240GB Mainstream SATA 6Gb Hot Swap SSD | 4XB7A10237 | B488 | 10 | Y* | Y | Y |
ThinkSystem 2.5" 5200 480GB Mainstream SATA 6Gb Hot Swap SSD | 4XB7A10238 | B489 | 10 | Y | Y | Y |
ThinkSystem 2.5" 5200 960GB Mainstream SATA 6Gb Hot Swap SSD | 4XB7A10239 | B48A | 10 | Y | Y | Y |
2.5-inch hot-swap SSDs - 5300 Mainstream 6 Gbps SATA | ||||||
ThinkSystem 2.5" 5300 240GB Mainstream SATA 6Gb Hot Swap SSD | 4XB7A17087 | B8J1 | 10 | N | Y | Y |
ThinkSystem 2.5" 5300 480GB Mainstream SATA 6Gb Hot Swap SSD | 4XB7A17088 | B8HY | 10 | Y | Y | Y |
ThinkSystem 2.5" 5300 960GB Mainstream SATA 6Gb Hot Swap SSD | 4XB7A17089 | B8J6 | 10 | Y | Y | Y |
ThinkSystem 2.5" 5300 1.92TB Mainstream SATA 6Gb Hot Swap SSD | 4XB7A17090 | B8JE | 10 | Y | Y | Y |
2.5-inch hot-swap SSDs - S4610 Mainstream 6 Gbps SATA | ||||||
ThinkSystem 2.5" Intel S4610 240GB Mainstream SATA 6Gb Hot Swap SSD | 4XB7A13633 | B49L | 10 | N | Y | Y |
ThinkSystem 2.5" Intel S4610 480GB Mainstream SATA 6Gb Hot Swap SSD | 4XB7A13634 | B49M | 10 | Y* | Y | Y |
ThinkSystem 2.5" Intel S4610 960GB Mainstream SATA 6Gb Hot Swap SSD | 4XB7A13635 | B49N | 10 | Y | Y | Y |
2.5-inch hot-swap SSDs - 5200 Entry 6 Gbps SATA | ||||||
ThinkSystem 2.5" 5200 480GB Entry SATA 6Gb Hot Swap SSD | 4XB7A10153 | B2X2 | 10 | N | Y | Y |
ThinkSystem 2.5" 5200 960GB Entry SATA 6Gb Hot Swap SSD | 4XB7A10154 | B2X3 | 10 | N | Y | Y |
2.5-inch hot-swap SSDs - 5300 Entry 6 Gbps SATA | ||||||
ThinkSystem 2.5" 5300 240GB Entry SATA 6Gb Hot Swap SSD | 4XB7A17075 | B8HV | 10 | N | Y | Y |
ThinkSystem 2.5" 5300 480GB Entry SATA 6Gb Hot Swap SSD | 4XB7A17076 | B8JM | 10 | N | Y | Y |
ThinkSystem 2.5" 5300 960GB Entry SATA 6Gb Hot Swap SSD | 4XB7A17077 | B8HP | 10 | Y* | Y | Y |
ThinkSystem 2.5" 5300 1.92TB Entry SATA 6Gb Hot Swap SSD | 4XB7A17078 | B8J5 | 10 | Y | Y | Y |
2.5-inch hot-swap SSDs - S4510 Entry 6 Gbps SATA | ||||||
ThinkSystem 2.5" Intel S4510 240GB Entry SATA 6Gb Hot Swap SSD | 4XB7A10247 | B498 | 10 | N | Y | Y |
ThinkSystem 2.5" Intel S4510 480GB Entry SATA 6Gb Hot Swap SSD | 4XB7A10248 | B499 | 10 | N | Y | Y |
ThinkSystem 2.5" Intel S4510 960GB Entry SATA 6Gb Hot Swap SSD | 4XB7A10249 | B49A | 10 | Y* | Y | Y |
* For hybrid storage configurations only; not available as a cache drive in all flash storage configurations.
Description | Part number | Feature code |
Maximum quantity
|
Cache
|
Capacity
|
Uncategorized
|
---|---|---|---|---|---|---|
3.5-inch hot-swap HDDs - 12 Gbps NL SAS | ||||||
ThinkSystem 3.5" 1TB 7.2K SAS 12Gb Hot Swap 512n HDD | 7XB7A00041 | AUU4 | 4 | N | Y | Y |
ThinkSystem 3.5" 2TB 7.2K SAS 12Gb Hot Swap 512n HDD | 7XB7A00042 | AUU5 | 4 | N | Y | Y |
ThinkSystem 3.5" 4TB 7.2K SAS 12Gb Hot Swap 512n HDD | 7XB7A00043 | AUU6 | 4 | N | Y | Y |
ThinkSystem 3.5" 6TB 7.2K SAS 12Gb Hot Swap 512e HDD | 7XB7A00044 | AUU7 | 4 | N | Y | Y |
ThinkSystem 3.5" 8TB 7.2K SAS 12Gb Hot Swap 512e HDD | 7XB7A00045 | B0YR | 4 | N | Y | Y |
3.5-inch hot-swap SSDs - 5200 Mainstream 6 Gbps SATA | ||||||
ThinkSystem 3.5" 5200 240GB Mainstream SATA 6Gb Hot Swap SSD | 4XB7A10242 | B48D | 4 | Y* | Y | Y |
ThinkSystem 3.5" 5200 480GB Mainstream SATA 6Gb Hot Swap SSD | 4XB7A10243 | B48E | 4 | Y | Y | Y |
ThinkSystem 3.5" 5200 960GB Mainstream SATA 6Gb Hot Swap SSD | 4XB7A10244 | B48F | 4 | Y | Y | Y |
3.5-inch hot-swap SSDs - 5300 Mainstream 6 Gbps SATA | ||||||
ThinkSystem 3.5" 5300 240GB Mainstream SATA 6Gb Hot Swap SSD | 4XB7A17096 | B8JL | 4 | N | Y | Y |
ThinkSystem 3.5" 5300 480GB Mainstream SATA 6Gb Hot Swap SSD | 4XB7A17097 | B8JF | 4 | Y | Y | Y |
ThinkSystem 3.5" 5300 960GB Mainstream SATA 6Gb Hot Swap SSD | 4XB7A17098 | B8J0 | 4 | Y | Y | Y |
ThinkSystem 3.5" 5300 1.92TB Mainstream SATA 6Gb Hot Swap SSD | 4XB7A17099 | B8HR | 4 | Y | Y | Y |
3.5-inch hot-swap SSDs - S4610 Mainstream 6 Gbps SATA | ||||||
ThinkSystem 3.5" Intel S4610 240GB Mainstream SATA 6Gb Hot Swap SSD | 4XB7A13639 | B49R | 4 | Y* | Y | Y |
ThinkSystem 3.5" Intel S4610 480GB Mainstream SATA 6Gb Hot Swap SSD | 4XB7A13640 | B49S | 4 | Y* | Y | Y |
ThinkSystem 3.5" Intel S4610 960GB Mainstream SATA 6Gb Hot Swap SSD | 4XB7A13641 | B49T | 4 | Y | Y | Y |
3.5-inch hot-swap SSDs - 5200 Entry 6 Gbps SATA | ||||||
ThinkSystem 3.5" 5200 480GB Entry SATA 6Gb Hot Swap SSD | 4XB7A10158 | B2X7 | 4 | N | Y | Y |
ThinkSystem 3.5" 5200 960GB Entry SATA 6Gb Hot Swap SSD | 4XB7A10159 | B2X8 | 4 | N | Y | Y |
3.5-inch hot-swap SSDs - 5300 Entry 6 Gbps SATA | ||||||
ThinkSystem 3.5" 5300 240GB Entry SATA 6Gb Hot Swap SSD | 4XB7A17081 | B8JB | 4 | N | Y | Y |
ThinkSystem 3.5" 5300 480GB Entry SATA 6Gb Hot Swap SSD | 4XB7A17082 | B8J9 | 4 | N | Y | Y |
ThinkSystem 3.5" 5300 960GB Entry SATA 6Gb Hot Swap SSD | 4XB7A17083 | B8JC | 4 | Y* | Y | Y |
ThinkSystem 3.5" 5300 1.92TB Entry SATA 6Gb Hot Swap SSD | 4XB7A17084 | B8HZ | 4 | Y | Y | Y |
3.5-inch hot-swap SSDs - S4510 Entry 6 Gbps SATA | ||||||
ThinkSystem 3.5" Intel S4510 240GB Entry SATA 6Gb Hot Swap SSD | 4XB7A13625 | B49D | 4 | N | Y | Y |
ThinkSystem 3.5" Intel S4510 480GB Entry SATA 6Gb Hot Swap SSD | 4XB7A13626 | B49E | 4 | N | Y | Y |
ThinkSystem 3.5" Intel S4510 960GB Entry SATA 6Gb Hot Swap SSD | 4XB7A13627 | B49F | 4 | Y* | Y | Y |
* For hybrid storage configurations only; not available as a cache drive in all flash storage configurations.
Configuration notes:
- The drives can be selected either from the Cache drives and Capacity drives categories if the hybrid or all flash storage configuration is selected, or from an uncategorized list if no storage type is selected.
- If the drives are selected from the Cache drives and Capacity drives categories, the following rules apply:
- 3.5-inch chassis: 1 drive group with 1 cache drive and from 2 to 3 capacity drives.
- 2.5-inch chassis:
- 1 drive group: 1 cache drive and from 2 to 7 capacity drives.
- 2 drive groups: 1 cache drive and from 2 to 4 capacity drives in each drive group.
- 3 drive groups: 1 cache drive and 2 capacity drives in each drive group.
- The quantity of the capacity drives in each drive group must be the same.
- All cache drives in the certified node must be of the same model and capacity. All capacity drives in the certified node must be of the same model and capacity.
I/O expansion
The ThinkAgile VX 1SE Certified Node supports up to three PCIe slots: one slot on the system planar that supports an internal storage controller and up to two PCIe slots on a riser card.
The slot form factors are as follows:
- Slot 1: PCIe 3.0 x8; low profile (not present if the Slot 2 is x16)
- Slot 2: PCIe 3.0 x8 (x16 physical connector) or x16; full-height, half-length
- Slot 4: PCIe 3.0 x4 (x8 physical connector; supports an internal storage controller)
The following table lists available PCIe riser card options.
Description | Part number | Feature code | Maximum quantity |
---|---|---|---|
ThinkSystem SR250/SR150 x8/x8 PCIe Riser | 4C57A12111 | B418 | 1 |
ThinkSystem SR250 x16 PCIe Riser | 4C57A12110 | B417 | 1 |
Configuration notes:
- A riser card is required for selection.
- The PCIe x8 riser card supplies slots 1 and 2, and the PCIe x16 riser card supplies slot 2.
Network connectivity
The ThinkAgile VX 1SE Certified Nodes provide two onboard Gigabit Ethernet network ports that are based on the Broadcom BCM5720 network interface controller (NIC) chip. Two, four, six, or eight additional 1 GbE RJ-45, 1/10 GbE RJ-45, or 10 GbE SFP+ ports, or two of four additional 10/25 GbE SFP28 ports can be selected, if required.
The following table lists the network adapter options that are available for selection.
Description | Part number | Feature code | Maximum quantity |
I/O slots supported |
---|---|---|---|---|
PCIe Low Profile adapters - 1 Gb Ethernet | ||||
Broadcom 5720 1GbE RJ45 2-Port PCIe Ethernet Adapter | 7ZT7A00482 | AUZX | 2 | 1, 2 |
Broadcom 5719 1GbE RJ45 4-Port PCIe Ethernet Adapter | 7ZT7A00484^ | AUZV^ | 2 | 1, 2 |
ThinkSystem I350-T2 PCIe 1Gb 2-Port RJ45 Ethernet Adapter | 7ZT7A00534 | AUZY | 2 | 1, 2 |
ThinkSystem I350-T4 PCIe 1Gb 4-Port RJ45 Ethernet Adapter | 7ZT7A00535 | AUZW | 2 | 1, 2 |
PCIe Low Profile adapters - 10 Gb Ethernet | ||||
Broadcom 57416 10GBASE-T 2-Port PCIe Ethernet Adapter | 7ZT7A00496 | AUKP | 2 | 1, 2 |
Emulex VFA5.2 2x10 GbE SFP+ PCIe Adapter | 00AG570 | AT7S | 2* | 1, 2 |
Intel X550-T1 Single Port 10GBase-T Adapter | 00MM850 | ATRY | 2 | 1, 2 |
Intel X550-T2 Dual Port 10GBase-T Adapter | 00MM860 | ATPX | 2 | 1, 2 |
Intel X710-DA2 PCIe 10Gb 2-Port SFP+ Ethernet Adapter | 7ZT7A00537 | AUKX | 2* | 1, 2 |
Intel X710-T4 PCIe 10Gb 4-Port Base-T Adapter | 7XC7A05927 | B0X1 | 2 | 1, 2 |
QLogic QL41134 PCIe 10Gb 4-Port Base-T Ethernet Adapter | 4XC7A08225 | B31G | 2 | 1, 2 |
PCIe Full Height adapters - 10 Gb Ethernet | ||||
Emulex OCe14104B-NX PCIe 10Gb 4-Port SFP+ Ethernet Adapter | 7ZT7A00493 | AUKN | 1* | 2 |
Intel X710-DA4 PCIe 10Gb 4-Port SFP+ Ethernet Adapter | 7XC7A05525 | B0YL | 1* | 2 |
PCIe Low Profile adapters - 25 Gb Ethernet | ||||
Broadcom 57412 10/25GbE SFP28 1-Port PCIe Ethernet Adapter | 7ZT7A00505 | AUKS | 2* | 1, 2 |
Intel XXV710-DA2 10/25GbE SFP28 2-Port PCIe Ethernet Adapter | 7XC7A05523 | B0WY | 2* | 1, 2 |
Mellanox ConnectX-4 Lx 10/25GbE SFP28 2-Port PCIe Eth. Adapter | 01GR250 | AUAJ | 2* | 1, 2 |
QLogic QL41262 10/25GbE SFP28 2-Port PCIe Ethernet Adapter | 4XC7A08228 | B21R | 2* | 1, 2 |
^ Field upgrade option only; no factory installation.
* The adapter comes without transceivers or cables; for ordering information, see the configuration notes below the table.
Configuration notes:
- PCIe full-height network adapters are supported in the full-height PCIe slot 2 supplied by the PCIe x8 or x16 riser card.
- PCIe Low Profile network adapters are supported in the full-height and low profile slots supplied by the PCIe x8 or x16 riser card.
- Supported transceivers or DAC cables should be purchased for the SFP+ and SFP28 ports, and UTP Category 6 or Category 5e cables should be purchased for the 10 GbE (Cat6) or 1 GbE (Cat5e or Cat6) RJ-45 ports. The maximum number of transceivers or cables that are supported per adapter equals the quantity of the adapter ports, and all adapter ports must have the same type of the transceiver or cable selected.
The following transceiver and cables can be purchased:
The following table lists cables for the 10 GbE and 1 GbE RJ-45 ports.
Description | Part number | Feature code |
---|---|---|
UTP Category 6 cables (Green) for 10 GbE and 1 GbE RJ-45 ports | ||
0.75m Cat6 Green Cable | 00WE123 | AVFW |
1.0m Cat6 Green Cable | 00WE127 | AVFX |
1.25m Cat6 Green Cable | 00WE131 | AVFY |
1.5m Cat6 Green Cable | 00WE135 | AVFZ |
3m Cat6 Green Cable | 00WE139 | AVG0 |
10m Cat6 Green Cable | 90Y3718 | A1MT |
25m Cat6 Green Cable | 90Y3727 | A1MW |
UTP Category 5e cables (Blue) for 1 GbE RJ-45 ports | ||
0.75m Blue Cat5e Cable | 00WE111 | AVFT |
1.0m Blue Cat5e Cable | 00WE115 | AVFU |
1.25m Blue Cat5e Cable | 00WE119 | AVFV |
1.5m Blue Cat5e Cable | 40K8785 | 3802 |
3m Blue Cat5e Cable | 40K5581 | 3803 |
10m Blue Cat5e Cable | 40K8927 | 3804 |
25m Blue Cat5e Cable | 40K8930 | 3805 |
UTP Category 5e cables (Green) for 1 GbE RJ-45 ports | ||
0.75m Green Cat5e Cable | 00WE099 | AVFQ |
1.0m Green Cat5e Cable | 00WE103 | AVFR |
1.25m Green Cat5e Cable | 00WE107 | AVFS |
1.5m Green Cat5e Cable | 40K5643 | 3797 |
3m Green Cat5e Cable | 40K5793 | 3798 |
10m Green Cat5e Cable | 40K5794 | 3799 |
25m Green Cat5e Cable | 40K8869 | 3800 |
The following table lists transceivers and cables for the 10 GbE SFP+ ports.
Description | Part number | Feature code |
---|---|---|
10 GbE transceivers for SFP+ ports | ||
Lenovo 10GBASE-SR SFP+ Transceiver | 46C3447 | 5053 |
Lenovo 10GBASE-LR SFP+ Transceiver | 00FE331* | B0RJ* |
Optical cables for 10 GbE SFP+ SR transceivers | ||
Lenovo 0.5m LC-LC OM3 MMF Cable | 00MN499 | ASR5 |
Lenovo 1m LC-LC OM3 MMF Cable | 00MN502 | ASR6 |
Lenovo 3m LC-LC OM3 MMF Cable | 00MN505 | ASR7 |
Lenovo 5m LC-LC OM3 MMF Cable | 00MN508 | ASR8 |
Lenovo 10m LC-LC OM3 MMF Cable | 00MN511 | ASR9 |
Lenovo 15m LC-LC OM3 MMF Cable | 00MN514 | ASRA |
Lenovo 25m LC-LC OM3 MMF Cable | 00MN517 | ASRB |
Lenovo 30m LC-LC OM3 MMF Cable | 00MN520 | ASRC |
Passive SFP+ DAC cables for 10 GbE SFP+ ports | ||
Lenovo 0.5m Passive SFP+ DAC Cable | 00D6288 | A3RG |
Lenovo 1m Passive SFP+ DAC Cable | 90Y9427 | A1PH |
Lenovo 1.5m Passive SFP+ DAC Cable | 00AY764 | A51N |
Lenovo 2m Passive SFP+ DAC Cable | 00AY765 | A51P |
Lenovo 3m Passive SFP+ DAC Cable | 90Y9430 | A1PJ |
Lenovo 5m Passive SFP+ DAC Cable | 90Y9433 | A1PK |
Lenovo 7m Passive SFP+ DAC Cable | 00D6151 | A3RH |
Active SFP+ DAC cables for 10 GbE SFP+ ports** | ||
Lenovo 1m Active DAC SFP+ Cable | 00VX111 | AT2R |
Lenovo 3m Active DAC SFP+ Cable | 00VX114 | AT2S |
Lenovo 5m Active DAC SFP+ Cable | 00VX117 | AT2T |
SFP+ active optical cables for 10 GbE SFP+ ports | ||
Lenovo 1m SFP+ to SFP+ Active Optical Cable | 00YL634 | ATYX |
Lenovo 3m SFP+ to SFP+ Active Optical Cable | 00YL637 | ATYY |
Lenovo 5m SFP+ to SFP+ Active Optical Cable | 00YL640 | ATYZ |
Lenovo 7m SFP+ to SFP+ Active Optical Cable | 00YL643 | ATZ0 |
Lenovo 15m SFP+ to SFP+ Active Optical Cable | 00YL646 | ATZ1 |
Lenovo 20m SFP+ to SFP+ Active Optical Cable | 00YL649 | ATZ2 |
* Not supported with the Intel X710-DA4 network adapter (7XC7A05525).
** The Emulex VFA5.2 PCIe network adapter (00AG570) does not support active SFP+ DAC cables.
The following table lists transceivers and cables for the 25 GbE SFP28 ports.
Description | Part number | Feature code |
---|---|---|
25 GbE transceivers for SFP28 ports | ||
Lenovo 25GBase-SR SFP28 Transceiver | 7G17A03537 | AV1B |
Optical cables for 25 GbE SFP28 SR transceivers | ||
Lenovo 0.5m LC-LC OM3 MMF Cable | 00MN499 | ASR5 |
Lenovo 1m LC-LC OM3 MMF Cable | 00MN502 | ASR6 |
Lenovo 3m LC-LC OM3 MMF Cable | 00MN505 | ASR7 |
Lenovo 5m LC-LC OM3 MMF Cable | 00MN508 | ASR8 |
Lenovo 10m LC-LC OM3 MMF Cable | 00MN511 | ASR9 |
Lenovo 15m LC-LC OM3 MMF Cable | 00MN514 | ASRA |
Lenovo 25m LC-LC OM3 MMF Cable | 00MN517 | ASRB |
Lenovo 30m LC-LC OM3 MMF Cable | 00MN520* | ASRC* |
Passive copper cables for 25 GbE SFP28 ports | ||
Lenovo 1m Passive 25G SFP28 DAC Cable | 7Z57A03557* | AV1W* |
Lenovo 3m Passive 25G SFP28 DAC Cable | 7Z57A03558 | AV1X |
Lenovo 5m Passive 25G SFP28 DAC Cable | 7Z57A03559 | AV1Y |
Active optical cables for 25 GbE SFP28 ports* | ||
Lenovo 3m 25G SFP28 Active Optical Cable | 7Z57A03541 | AV1F |
Lenovo 5m 25G SFP28 Active Optical Cable | 7Z57A03542 | AV1G |
Lenovo 10m 25G SFP28 Active Optical Cable | 7Z57A03543 | AV1H |
Lenovo 15m 25G SFP28 Active Optical Cable | 7Z57A03544 | AV1J |
Lenovo 20m 25G SFP28 Active Optical Cable | 7Z57A03545 | AV1K |
* Not supported with the Intel XXV710-DA2 PCIe 25Gb 2-Port SFP28 Ethernet Adapter (7XC7A05523).
For more information, see the list of Product Guides in the Ethernet Adapters category:
http://lenovopress.com/servers/options/ethernet#rt=product-guide
Power supplies and cables
The VX 1SE Certified Nodes can be configured with one fixed power supply or up to two redundant hot-swap power supplies. With two power supplies, the node is capable of N+N redundancy depending on the configuration. A second power supply can be added to the models that come with one hot-swap power supply.
The following table lists the power supply options that are available for selection.
Description | Part number | Feature code | Maximum quantity |
---|---|---|---|
ThinkSystem SR250/SR150 Fixed 300W Power Supply | None* | B40Q | 1 |
ThinkSystem 450W (230V/115V) Platinum Hot-Swap Power Supply | 4P57A12649 | B40R | 2 |
* Factory-installed only.
Configuration note: To ensure that the properly sized power supply is chosen for optimal performance, it is highly recommended to validate system configuration for specific power requirements by using the latest version of the Lenovo Capacity Planner:
http://datacentersupport.lenovo.com/us/en/solutions/lnvo-lcp
The VX 1SE Certified Nodes ship without a power cord, or with one or two customer-configured power cords. A hot-swap power supply option ships without a power cord.
The following table lists the line cords and rack power cables that can be ordered for the VX 1SE Certified Node. One or two power cables can be ordered, depending on the quantity of power supplies in the appliance.
Description | Part number | Feature code |
---|---|---|
Rack power cables | ||
1.0m, 10A/100-250V, C13 to IEC 320-C14 Rack Power Cable | 00Y3043 | A4VP |
1.5m, 10A/100-250V, C13 to IEC 320-C14 Rack Power Cable | 39Y7937 | 6201 |
2.0m, 10A/100-250V, C13 to IEC 320-C14 Rack Power Cable | 4L67A08365 | B0N4 |
2.0m, 13A/125V-10A/250V, C13 to IEC 320-C14 Rack Power Cable | 4L67A08369 | 6570 |
2.8m, 10A/100-250V, C13 to IEC 320-C14 Rack Power Cable | 4L67A08366 | 6311 |
2.8m, 13A/125V-10A/250V, C13 to IEC 320-C14 Rack Power Cable | 4L67A08370 | 6400 |
2.8m, 10A/100-250V, C13 to IEC 320-C20 Rack Power Cable | 39Y7938 | 6204 |
4.3m, 10A/100-250V, C13 to IEC 320-C14 Rack Power Cable | 39Y7932 | 6263 |
4.3m, 13A/125V-10A/250V, C13 to IEC 320-C14 Rack Power Cable | 4L67A08371 | 6583 |
Line cords | ||
Argentina 2.8m, 10A/250V, C13 to IRAM 2073 Line Cord | 39Y7930 | 6222 |
Argentina 4.3m, 10A/250V, C13 to IRAM 2073 Line Cord | 81Y2384 | 6492 |
Australia/New Zealand 2.8m, 10A/250V, C13 to AS/NZS 3112 Line Cord | 39Y7924 | 6211 |
Australia/New Zealand 4.3m, 10A/250V, C13 to AS/NZS 3112 Line Cord | 81Y2383 | 6574 |
Brazil 2.8m, 10A/250V, C13 to NBR 14136 Line Cord | 69Y1988 | 6532 |
Brazil 4.3m, 10A/250V, C13 to NBR14136 Line Cord | 81Y2387 | 6404 |
China 2.8m, 10A/250V, C13 to GB 2099.1 Line Cord | 39Y7928 | 6210 |
China 4.3m, 10A/250V, C13 to GB 2099.1 Line Cord | 81Y2378 | 6580 |
Denmark 2.8m, 10A/250V, C13 to DK2-5a Line Cord | 39Y7918 | 6213 |
Denmark 4.3m, 10A/250V, C13 to DK2-5a Line Cord | 81Y2382 | 6575 |
Europe 2.8m, 10A/250V, C13 to CEE7-VII Line Cord | 39Y7917 | 6212 |
Europe 4.3m, 10A/250V, C13 to CEE7-VII Line Cord | 81Y2376 | 6572 |
Israel 2.8m, 10A/250V, C13 to SI 32 Line Cord | 39Y7920 | 6218 |
Israel 4.3m, 10A/250V, C13 to SI 32 Line Cord | 81Y2381 | 6579 |
Italy 2.8m, 10A/250V, C13 to CEI 23-16 Line Cord | 39Y7921 | 6217 |
Italy 4.3m, 10A/250V, C13 to CEI 23-16 Line Cord | 81Y2380 | 6493 |
Japan 2.8m, 12A/125V, C13 to JIS C-8303 Line cord | 46M2593 | A1RE |
Japan 2.8m, 12A/250V, C13 to JIS C-8303 Line Cord | 4L67A08357 | 6533 |
Japan 4.3m, 12A/125V, C13 to JIS C-8303 Line Cord | 39Y7926 | 6335 |
Japan 4.3m, 12A/250V, C13 to JIS C-8303 Line Cord | 4L67A08362 | 6495 |
Korea 2.8m, 12A/250V, C13 to KS C8305 Line Cord | 39Y7925 | 6219 |
Korea 4.3m, 12A/250V, C13 to KS C8305 Line Cord | 81Y2385 | 6494 |
South Africa 2.8m, 10A/250V, C13 to SABS 164 Line Cord | 39Y7922 | 6214 |
South Africa 4.3m, 10A/250V, C13 to SABS 164 Line Cord | 81Y2379 | 6576 |
Switzerland 2.8m, 10A/250V, C13 to SEV 1011-S24507 Line Cord | 39Y7919 | 6216 |
Switzerland 4.3m, 10A/250V, C13 to SEV 1011-S24507 Line Cord | 81Y2390 | 6578 |
Taiwan 2.8m, 10A/125V, C13 to CNS 10917-3 Line Cord | 23R7158 | 6386 |
Taiwan 2.8m, 10A/250V, C13 to CNS 10917-3 Line Cord | 81Y2375 | 6317 |
Taiwan 4.3m, 10A/125V, C13 to CNS 10917-3 Line Cord | 4L67A08363 | AX8B |
Taiwan 4.3m, 10A/250V, C13 to CNS 10917-3 Line Cord | 81Y2389 | 6531 |
United Kingdom 2.8m, 10A/250V, C13 to BS 1363/A Line Cord | 39Y7923 | 6215 |
United Kingdom 4.3m, 10A/250V, C13 to BS 1363/A Line Cord | 81Y2377 | 6577 |
United States 2.8m, 10A/125V, C13 to NEMA 5-15P Line Cord | 90Y3016 | 6313 |
United States 2.8m, 10A/250V, C13 to NEMA 6-15P Line Cord | 46M2592 | A1RF |
United States 4.3m, 10A/125V, C13 to NEMA 5-15P Line Cord | 4L67A08359 | 6370 |
United States 4.3m, 10A/250V, C13 to NEMA 6-15P Line Cord | 4L67A08361 | 6373 |
Rack installation
The VX 1SE Certified Nodes ship with or without a rail kit, depending on the rack installation option selected. The following table lists the rack installation options that are available for the VX 1SE Certified Nodes.
Description | Part number | Feature code | Maximum quantity |
---|---|---|---|
4-post rail kit | |||
ThinkSystem Tool-less Friction Rail v2 | 4M17A13564 | B42B | 1 |
Front VGA port | |||
ThinkSystem SR250/SR150 Front VGA Connector Kit | 4Z57A12653 | B419 | 1 |
Lockable front bezel | |||
ThinkSystem 1U Security Bezel | 7Z17A02581 | AUWR | 1 |
The following table summarizes the rail kit features and specifications.
Feature | 4-Post Tool-less Rail Kit |
---|---|
Part number | 4M17A13564 |
CMA | None |
Rail length | 751.2 mm (29.6 in.) |
Rail type | Half-out slide (friction) |
Tool-less installation | Yes |
In-rack server maintenance | No |
1U PDU support | Yes |
0U PDU support | Limited* |
Rack type | IBM or Lenovo 4-post, EIA standard-compliant |
Mounting holes | Square or round |
Mounting flange thickness | 2 mm (0.08 in.) – 3.3 mm (0.13 in.) |
Distance between front and rear mounting flanges^ | 609.6 mm (24 in.) – 863.6 mm (34 in.) |
* If a 0U PDU used, the rack cabinet must be at least 1000 mm (39.37 in.) deep.
^ Measured when mounted on the rack cabinet, from the front surface of the front mounting flange to the rear most point of the rail.
Software
The ThinkAgile VX Certified Nodes support the following VMware HCI components:
- VMware vSphere ESXi hypervisor
- VMware vSAN distributed enterprise storage
- VMware vCenter Server centralized management
The VMware ESXi hypervisor is factory-preinstalled on the M.2 SSD.
The following table lists the VMware ESXi hypervisor versions that are available for selection.
Description | Feature code |
---|---|
VMware ESXi 6.5 U2 (Factory Installed) | B3VW |
VMware ESXi 6.5 U3 (Factory installed) | B6U0 |
VMware ESXi 6.7 U2 (Factory Installed) | B6U1 |
VMware ESXi 6.7 U3 (Factory installed) | B88T |
VMware software licenses and support are not included with ThinkAgile VX Certified Nodes. Customers can use the existing VMware software licenses and active support contracts, or they can purchase software licenses and support from VMware or Lenovo.
Lenovo offers the following VMware software license and support options for ThinkAgile VX Certified Nodes:
Configuration notes:
- The selection of VMware software licenses is optional.
- VMware software licenses are available with 1-year, 3-year, or 5-year software support and subscription.
- The quantity of VM-based licenses is specified based on the VM requirements.
- The quantity of CCU-based licenses is specified based on the concurrent user requirements.
VMware vSAN License and Subscription
Lenovo offers the following VMware vSAN License and Subscription options that can be purchased for ThinkAgile VX Certified Nodes:
- VMware Virtual SAN 6 Standard provides support for hybrid and all-flash storage configurations.
- VMware Virtual SAN 6 Advanced provides support for hybrid and all-flash storage configurations with space efficiency features (compression, deduplication, and erasure coding).
- VMware Virtual SAN 6 Enterprise provides support for hybrid and all-flash storage configurations with space efficiency features (compression, deduplication, and erasure coding), stringent security (data-at-rest encryption), and advanced failure protection (stretched cluster).
- VMware Virtual SAN 6 Enterprise Plus is a bundle of vSAN Enterprise and vRealize Operations Advanced features.
- VMware Virtual SAN 6 for Remote Office Branch Office (ROBO) provides support for hybrid and all-flash storage configurations for up to 25 virtual machines at remote locations.
- VMware Virtual SAN 6 for Desktop provides support for hybrid and all-flash storage configurations for customers using vSAN exclusively for virtual desktop infrastructure.
The following table lists ordering information for the VMware vSAN License and Subscription options.
Description | Part number | Feature code |
---|---|---|
vSAN 6 Standard | ||
VMware vSAN 6 Standard for 1 Processor w/1Yr Support | 7S06001HWW | B28W |
VMware vSAN 6 Standard for 1 Processor w/3Yr Support | 7S06004TWW | B2C6 |
VMware vSAN 6 Standard for 1 Processor w/5Yr Support | 7S060083WW | B2FG |
vSAN 6 Advanced | ||
VMware vSAN 6 Advanced for 1 Processor w/1Yr Support | 7S06001MWW | B290 |
VMware vSAN 6 Advanced for 1 Processor w/3Yr Support | 7S06004XWW | B2CA |
VMware vSAN 6 Advanced for 1 Processor w/5Yr Support | 7S060087WW | B2FL |
vSAN 6 Enterprise | ||
VMware vSAN 6 Enterprise for 1 Processor w/1Yr Support | 7S06001RWW | B294 |
VMware vSAN 6 Enterprise for 1 Processor w/3Yr Support | 7S060051WW | B2CE |
VMware vSAN 6 Enterprise for 1 Processor w/5Yr Support | 7S06008BWW | B2FQ |
vSAN 6 Enterprise Plus | ||
VMware vSAN 6 Enterprise Plus for 1 Processor w/1Y Support and Subscription | 7S0600FRWW | S226 |
VMware vSAN 6 Enterprise Plus for 1 Processor w/3Y Support and Subscription | 7S0600FSWW | S227 |
VMware vSAN 6 Enterprise Plus for 1 Processor w/5Y Support and Subscription | 7S0600FTWW | S228 |
vSAN 6 Standard for Remote Office Branch Office (ROBO) | ||
VMware vSAN 6 Standard for Rmt Off Brnch Off 25VM Pk w/1Yr Support | 7S06001LWW | B28Z |
VMware vSAN 6 Standard for Rmt Off Brnch Off 25VM Pk w/3Yr Support | 7S06004WWW | B2C9 |
VMware vSAN 6 Standard for Rmt Off Brnch Off 25VM Pk w/5Yr Support | 7S060086WW | B2FK |
vSAN 6 Advanced for Remote Office Branch Office | ||
VMware vSAN 6 Advanced for Rmt Off Brnch Off 25VM Pk w/1Yr Support | 7S06001QWW | B293 |
VMware vSAN 6 Advanced for Rmt Off Brnch Off 25VM Pk w/3Yr Support | 7S060050WW | B2CD |
VMware vSAN 6 Advanced for Rmt Off Brnch Off 25VM Pk w/5Yr Support | 7S06008AWW | B2FP |
vSAN 6 Enterprise for Remote Office Branch Office | ||
VMware vSAN 6 Enterprise for Rmt Off Brnch Off 25VM Pk w/1Yr Support | 7S06001UWW | B297 |
VMware vSAN 6 Enterprise for Rmt Off Brnch Off 25VM Pk w/3Yr Support | 7S060054WW | B2CH |
VMware vSAN 6 Enterprise for Rmt Off Brnch Off 25VM Pk w/5Yr Support | 7S06008EWW | B2FT |
vSAN 6 Standard for Desktop | ||
VMware vSAN 6 Standard for Desktop 10 Conc User Pk w/1Yr Support | 7S06001JWW | B28X |
VMware vSAN 6 Standard for Desktop 10 Conc User Pk w/3Yr Support | 7S06004UWW | B2C7 |
VMware vSAN 6 Standard for Desktop 10 Conc User Pk w/5Yr Support | 7S060084WW | B2FH |
VMware vSAN 6 Standard for Desktop 100 Conc User Pk w/1Yr Support | 7S06001KWW | B28Y |
VMware vSAN 6 Standard for Desktop 100 Conc User Pk w/3Yr Support | 7S06004VWW | B2C8 |
VMware vSAN 6 Standard for Desktop 100 Conc User Pk w/5Yr Support | 7S060085WW | B2FJ |
vSAN 6 Advanced for Desktop | ||
VMware vSAN 6 Advanced for Desktop 10 Conc User Pk w/1Yr Support | 7S06001NWW | B291 |
VMware vSAN 6 Advanced for Desktop 10 Conc User Pk w/3Yr Support | 7S06004YWW | B2CB |
VMware vSAN 6 Advanced for Desktop 10 Conc User Pk w/5Yr Support | 7S060088WW | B2FM |
VMware vSAN 6 Advanced for Desktop 100 Conc User Pk w/1Yr Support | 7S06001PWW | B292 |
VMware vSAN 6 Advanced for Desktop 100 Conc User Pk w/3Yr Support | 7S06004ZWW | B2CC |
VMware vSAN 6 Advanced for Desktop 100 Conc User Pk w/5Yr Support | 7S060089WW | B2FN |
vSAN 6 Enterprise for Desktop | ||
VMware vSAN 6 Enterprise for Desktop 10 Conc User Pk w/1Yr Support | 7S06001SWW | B295 |
VMware vSAN 6 Enterprise for Desktop 10 Conc User Pk w/3Yr Support | 7S060052WW | B2CF |
VMware vSAN 6 Enterprise for Desktop 10 Conc User Pk w/5Yr Support | 7S06008CWW | B2FR |
VMware vSAN 6 Enterprise for Desktop 100 Conc User Pk w/1Yr Support | 7S06001TWW | B296 |
VMware vSAN 6 Enterprise for Desktop 100 Conc User Pk w/3Yr Support | 7S060053WW | B2CG |
VMware vSAN 6 Enterprise for Desktop 100 Conc User Pk w/5Yr Support | 7S06008DWW | B2FS |
The following table compares features of the VMware vSAN software editions.
Feature | VMware vSAN software edition | |||
---|---|---|---|---|
Standard | Advanced | Enterprise | Enterprise Plus | |
Licensing for data center | Processor-based (per 1 processor) | |||
Licensing for ROBO | VM-based (per 25 VMs)* | Not applicable | ||
Licensing for Desktop | Concurrent user-based (per 10 or 100 users) | Not applicable | ||
Cluster size | 2 - 64 | 2 - 64 | 2 - 64 | 2 - 64 |
Storage-Policy Based Management | Yes | Yes | Yes | Yes |
Flash Read/Write Caching | Yes | Yes | Yes | Yes |
Distributed RAID | Yes | Yes | Yes | Yes |
Virtual Distributed Switch | Yes | Yes | Yes | Yes |
Rack Awareness | Yes | Yes | Yes | Yes |
vSphere Replication | Yes | Yes | Yes | Yes |
Software Checksum | Yes | Yes | Yes | Yes |
All-Flash Hardware | Yes | Yes | Yes | Yes |
iSCSI Target Service | Yes | Yes | Yes | Yes |
IOPS Limit | Yes | Yes | Yes | Yes |
Deduplication and Compression | No | Yes** | Yes** | Yes** |
RAID-5/6 Erasure Coding | No | Yes** | Yes** | Yes** |
Data-at-Rest Encryption | No | No | Yes | Yes |
Stretched Cluster with Local Failure Protection | No | No | Yes | Yes |
vRealize Operations Advanced | No | No | No | Yes |
* A maximum of 25 VMs is supported at any single location under the ROBO license. Two or more nodes can be used in a cluster under the ROBO license, however, the maximum number of VMs at the location must not exceed 25.
** Requires All-Flash configurations; hybrid configurations not supported.
VMware vSphere License and Subscription
Lenovo offers the following VMware vSphere License and Subscription options that can be purchased for ThinkAgile VX Certified Nodes:
- VMware vSphere 6 Standard provides an entry-level solution for basic server consolidation and business continuity.
- VMware vSphere 6 Enterprise Plus offers resource management with enhanced application availability and performance for server virtualization and cloud solutions.
- VMware vSphere 6 Remote Office Branch Office (ROBO) Standard provides remote site server virtualization with business continuity and backup features.
- VMware vSphere 6 Remote Office Branch Office Advanced provides remote site server virtualization that offers business continuity and backup with advanced features such as standardization of host configurations.
Note: Lenovo also offers VMware vSphere 6 Remote Office Branch Office (ROBO) Enterprise as a part of the VMware 6 HCI Kit for ROBO Standard or Advanced, and it provides remote site server virtualization and consolidation with business continuity and backup, standardization of host configurations, and data security through encryption.
The following table lists ordering information for the VMware vSphere License and Subscription options.
Description | Part number | Feature code |
---|---|---|
vSphere 6 Standard | ||
VMware vSphere 6 Standard for 1 Processor w/1Yr Support | 7S060003WW | B27G |
VMware vSphere 6 Standard for 1 Processor w/3Yr Support | 7S06003DWW | B2AS |
VMware vSphere 6 Standard for 1 Processor w/5Yr Support | 7S06006PWW | B2E2 |
vSphere 6 Enterprise Plus | ||
VMware vSphere 6 Enterprise Plus for 1 Processor w/1Yr Support | 7S060004WW | B27H |
VMware vSphere 6 Enterprise Plus for 1 Processor w/3Yr Support | 7S06003EWW | B2AT |
VMware vSphere 6 Enterprise Plus for 1 Processor w/5Yr Support | 7S06006QWW | B2E3 |
vSphere 6 for Remote Office Branch Office Standard | ||
VMware vSphere 6 Remote Off Branch Off Std (25 VM Pk) w/1Yr Support | 7S060009WW | B27N |
VMware vSphere 6 Remote Off Branch Off Std (25 VM Pk) w/3Yr Support | 7S06003KWW | B2AY |
VMware vSphere 6 Remote Off Branch Off Std (25 VM Pk) w/5Yr Support | 7S06006VWW | B2E8 |
vSphere 6 for Remote Office Branch Office Advanced | ||
VMware vSphere 6 Remote Off Branch Off Adv (25 VM Pk) w/1Yr Support | 7S06000AWW | B27P |
VMware vSphere 6 Remote Off Branch Off Adv (25 VM Pk) w/3Yr Support | 7S06003LWW | B2AZ |
VMware vSphere 6 Remote Off Branch Off Adv (25 VM Pk) w/5Yr Support | 7S06006WWW | B2E9 |
The following table compares features of the VMware vSphere software editions.
Feature | VMware vSphere software edition | ||||
---|---|---|---|---|---|
Standard | Enterprise Plus |
ROBO Standard |
ROBO Advanced |
ROBO Enterprise |
|
Licensing | Processor-based (per 1 processor) | VM-based (per 25 VMs) | |||
Hypervisor | Yes | Yes | Yes | Yes | Yes |
vMotion | Yes | Yes | Yes | Yes | Yes |
Storage vMotion | Yes | Yes | Yes | Yes | Yes |
Cross-Switch vMotion | Yes | Yes | No | No | No |
Fault Tolerance | 2 vCPU | 8 vCPU | 2 vCPU | 4 vCPU | 4 vCPU |
Data Protection and Replication | Yes | Yes | Yes | Yes | Yes |
Virtual Volumes | Yes | Yes | Yes | Yes | Yes |
Storage-Policy Based Management | Yes | Yes | Yes | Yes | Yes |
APIs for Storage Awareness | Yes | Yes | No | No | No |
APIs for Array Integration, Multipathing | Yes | Yes | No | No | No |
Content Library | Yes | Yes | No | No | No |
vCenter High Availability | Yes* | Yes* | No | No | No |
vCenter Backup and Restore | Yes* | Yes* | No | No | No |
vCenter Server Appliance Migration Tool | Yes* | Yes* | No | No | No |
Virtual Machine Encryption | No | Yes | No | No | Yes |
Proactive High Availability | No | Yes | No | No | No |
vSphere Integrated Containers | No | Yes | No | Yes | Yes |
Distributed Resource Scheduler (DRS) | No | Yes | No | No | Yes** |
Distributed Power Management | No | Yes | No | No | No |
Big Data Extensions | No | Yes | No | No | No |
Distributed Switch | No | Yes | No | Yes | Yes |
Storage DRS | No | Yes | No | No | No |
I/O Controls (Network and Storage) and SR-IOV | No | Yes | No | No | No |
Host Profiles and Auto Deploy | No | Yes | No | Yes | Yes |
Flash Read Cache | No | Yes | No | No | No |
Cross-vCenter and Long Distance vMotion | No | Yes | No | No | No |
vGPU | No | Yes | No | No | No |
* Requires vCenter Server Standard.
** DRS Maintenance Mode functionality.
VMware HCI Kit License and Subscription
Lenovo offers the following VMware HCI license bundles for ThinkAgile VX Certified Nodes that include both vSphere and vSAN License and Subscription options:
- VMware HCI Kit Essentials (For 3 nodes):
- vSphere Essentials Plus
- vSAN Standard
- VMware HCI Kit Standard (Per CPU):
- vSphere Standard
- vSAN Standard
- VMware HCI Kit Advanced (Per CPU):
- vSphere Enterprise Plus
- vSAN Advanced
- VMware HCI Kit Enterprise (Per CPU):
- vSphere Enterprise Plus
- vSAN Enterprise
- VMware HCI Kit with Operations Management (Per CPU):
- vSphere Enterprise Plus
- vSAN Enterprise Plus
- VMware HCI Kit ROBO Standard (Per 25 VMs):
- vSphere ROBO Enterprise
- vSAN ROBO Standard
- VMware HCI Kit ROBO Advanced (Per 25 VMs):
- vSphere ROBO Enterprise
- vSAN ROBO Advanced
Note: VMware vSphere Essentials Plus provides server virtualization and consolidation with centralized management and business continuity for up to three nodes, and it includes the following features: vSphere Hypervisor, vMotion, Cross-Switch vMotion, High Availability, Data Protection and Replication, and vCenter Server Essentials.
The following table lists ordering information for the VMware HCI Kit License and Subscription options.
Description | Part number | Feature code |
---|---|---|
HCI Kit Essentials | ||
VMware HCI Kit Essentials for 3 Nodes w/1Yr Support | 7S0600A6WW | S04C |
VMware HCI Kit Essentials for 3 Nodes w/3Yr Support | 7S0600A9WW | S04F |
VMware HCI Kit Essentials for 3 Nodes w/5Yr Support | 7S0600ACWW | S04J |
HCI Kit Standard | ||
VMware HCI Kit Standard (Per CPU) w/1Yr Support | 7S06001XWW | B29A |
VMware HCI Kit Standard (Per CPU) w/3Yr Support | 7S060057WW | B2CL |
VMware HCI Kit Standard (Per CPU) w/5Yr Support | 7S06008HWW | B2FW |
HCI Kit Advanced | ||
VMware HCI Kit Advanced (Per CPU) w/1Yr Support | 7S06001YWW | B29B |
VMware HCI Kit Advanced (Per CPU) w/3Yr Support | 7S060058WW | B2CM |
VMware HCI Kit Advanced (Per CPU) w/5Yr Support | 7S06008JWW | B2FX |
HCI Kit Enterprise | ||
VMware HCI Kit Enterprise (Per CPU) w/1Yr Support | 7S06001ZWW | B29C |
VMware HCI Kit Enterprise (Per CPU) w/3Yr Support | 7S060059WW | B2CN |
VMware HCI Kit Enterprise (Per CPU) w/5Yr Support | 7S06008KWW | B2FY |
HCI Kit Enterprise with Operations Management | ||
VMware HCI Kit 6 with Operations Management (Per CPU) w/1Y S&S | 7S0600GFWW | S22W |
VMware HCI Kit 6 with Operations Management (Per CPU) w/3Y S&S | 7S0600GGWW | S22X |
VMware HCI Kit 6 with Operations Management (Per CPU) w/5Y S&S | 7S0600GHWW | S22Y |
HCI Kit Standard for Remote Office Branch Office | ||
VMware HCI Kit 6 for Remote Office Branch Office Standard (25 VM pack) w/1Y S&S | 7S0600G6WW | S22M |
VMware HCI Kit 6 for Remote Office Branch Office Standard (25 VM pack) w/3Y S&S | 7S0600G7WW | S22N |
VMware HCI Kit 6 for Remote Office Branch Office Standard (25 VM pack) w/5Y S&S | 7S0600G8WW | S22P |
HCI Kit Advanced for Remote Office Branch Office | ||
VMware HCI Kit 6 for Remote Office Branch Office Advanced (25 VM pack) w/1Y S&S | 7S0600G3WW | S22J |
VMware HCI Kit 6 for Remote Office Branch Office Advanced (25 VM pack) w/3Y S&S | 7S0600G4WW | S22K |
VMware HCI Kit 6 for Remote Office Branch Office Advanced (25 VM pack) w/5Y S&S | 7S0600G5WW | S22L |
VMware Horizon 7
Lenovo offers the following VMware Horizon 7 License and Subscription options for Virtual Desktop Infrastructure (VDI) deployments that can be purchased for the ThinkAgile VX Certified Nodes:
- VMware Horizon 7 Standard delivers simple, powerful VDI with great user experience, and it includes VMware vSphere Desktop (delivers the full range of vSphere 6 Enterprise Plus features for desktop workloads) and vCenter Server for Desktop.
- VMware Horizon 7 Advanced delivers desktops and applications for physical and virtual machines through a unified workspace, and it includes VMware vSphere Desktop, vCenter Server for Desktop, and vSAN Advanced for Desktop with All-Flash.
- VMware Horizon 7 Enterprise delivers desktops and applications with closed-loop management and automation, and it includes VMware vSphere Desktop, vCenter Server for Desktop, and vSAN Advanced for Desktop with All-Flash.
The Standard license is available in 10-user or 100-user packs for concurrent users, and the Advanced and Enterprise licenses are available in 10-user or 100-user packs for concurrent or named users.
The following table lists ordering information for the VMware Horizon License and Subscription options.
Description | Part number | Feature code |
---|---|---|
Horizon 7 Standard | ||
VMware Horizon 7 Standard 10 Concurrent User Pack w/1Yr Support | 7S06000KWW | B27Y |
VMware Horizon 7 Standard 10 Concurrent User Pack w/3Yr Support | 7S06003VWW | B2B8 |
VMware Horizon 7 Standard 10 Concurrent User Pack w/5Yr Support | 7S060075WW | B2EJ |
VMware Horizon 7 Standard 100 Concurrent User Pack w/1Yr Support | 7S06000LWW | B27Z |
VMware Horizon 7 Standard 100 Concurrent User Pack w/3Yr Support | 7S06003WWW | B2B9 |
VMware Horizon 7 Standard 100 Concurrent User Pack w/5Yr Support | 7S060076WW | B2EK |
Horizon 7 Advanced | ||
VMware Horizon 7 Advanced 10 Concurrent User Pack w/1Yr Support | 7S06000PWW | B282 |
VMware Horizon 7 Advanced 10 Concurrent User Pack w/3Yr Support | 7S06003ZWW | B2BC |
VMware Horizon 7 Advanced 10 Concurrent User Pack w/5Yr Support | 7S060079WW | B2EN |
VMware Horizon 7 Advanced 10 Named User Pack w/1Yr Support | 7S06000RWW | B284 |
VMware Horizon 7 Advanced 10 Named User Pack w/3Yr Support | 7S060041WW | B2BE |
VMware Horizon 7 Advanced 10 Named User Pack w/5Yr Support | 7S06007BWW | B2EQ |
VMware Horizon 7 Advanced 100 Concurrent User Pack w/1Yr Support | 7S06000QWW | B283 |
VMware Horizon 7 Advanced 100 Concurrent User Pack w/3Yr Support | 7S060040WW | B2BD |
VMware Horizon 7 Advanced 100 Concurrent User Pack w/5Yr Support | 7S06007AWW | B2EP |
VMware Horizon 7 Advanced 100 Named User Pack w/1Yr Support | 7S06000SWW | B285 |
VMware Horizon 7 Advanced 100 Named User Pack w/3Yr Support | 7S060042WW | B2BF |
VMware Horizon 7 Advanced 100 Named User Pack w/5Yr Support | 7S06007CWW | B2ER |
Horizon 7 Enterprise | ||
VMware Horizon 7 Enterprise 10 Concurrent User Pack w/1Yr Support | 7S06000XWW | B28A |
VMware Horizon 7 Enterprise 10 Concurrent User Pack w/3Yr Support | 7S060047WW | B2BL |
VMware Horizon 7 Enterprise 10 Concurrent User Pack w/5Yr Support | 7S06007HWW | B2EW |
VMware Horizon 7 Enterprise 10 Named User Pack w/1Yr Support | 7S06000ZWW | B28C |
VMware Horizon 7 Enterprise 10 Named User Pack w/3Yr Support | 7S060049WW | B2BN |
VMware Horizon 7 Enterprise 10 Named User Pack w/5Yr Support | 7S06007KWW | B2EY |
VMware Horizon 7 Enterprise 100 Concurrent User Pack w/1Yr Support | 7S06000YWW | B28B |
VMware Horizon 7 Enterprise 100 Concurrent User Pack w/3Yr Support | 7S060048WW | B2BM |
VMware Horizon 7 Enterprise 100 Concurrent User Pack w/5Yr Support | 7S06007JWW | B2EX |
VMware Horizon 7 Enterprise 100 Named User Pack w/1Yr Support | 7S060010WW | B28D |
VMware Horizon 7 Enterprise 100 Named User Pack w/3Yr Support | 7S06004AWW | B2BP |
VMware Horizon 7 Enterprise 100 Named User Pack w/5Yr Support | 7S06007LWW | B2EZ |
The following table compares key features of the VMware Horizon software editions.
Feature | VMware Horizon software edition | ||
---|---|---|---|
Standard | Advanced | Enterprise | |
Licensing | User-based (per 10 or 100 users) | ||
Concurrent Users | Yes | Yes | Yes |
Named Users | No | Yes | Yes |
Windows Virtual Desktops | Yes | Yes | Yes |
Linux Virtual Desktops | No | No | Yes |
Packaged Applications | Yes | Yes | Yes |
Hosted Applications | No | Yes | Yes |
Session-based Desktops | No | Yes | Yes |
Single Sign-On for Application and Desktop Access | No | Yes | Yes |
Image Management for Physical Desktop | No | Yes | Yes |
Virtualization Pack for Skype for Business | No | Yes | Yes |
Session Collaboration | No | No | Yes |
Real-time Application Delivery | No | No | Yes |
Just-in-Time Delivery with Instant Clone Technology | No | No | Yes |
User, Profile, and Policy Management | No | No | Yes |
Health Monitoring and Performance Analytics | No | No | Yes |
Capacity Management: Planning and Optimization | No | No | Yes |
Help Desk Tool | No | No | Yes |
VMware Cloud Foundation
Lenovo offers VMware Cloud Foundation for hybrid cloud deployments of the ThinkAgile VX Certified Nodes. VMware Cloud Foundation is an integrated software platform that automates the deployment and lifecycle management of a complete software-defined data center (SDDC) in hyperconverged environments.
The following Cloud Foundation License and Subscription options are offered:
- Cloud Foundation Basic includes vSphere Enterprise Plus, vSAN Advanced, NSX Data Center Professional, and SDDC Manager.
- Cloud Foundation Standard includes vSphere Enterprise plus, vSAN Advanced, NSX Data Center Advanced, vRealize Suite Standard, vRealize Network Insight Advanced, and SDDC Manager.
- Cloud Foundation Advanced includes vSphere Enterprise plus, vSAN Advanced, NSX Data Center Advanced, vRealize Suite Enterprise, vRealize Network Insight Advanced, and SDDC Manager.
- Cloud Foundation Enterprise includes vSphere Enterprise plus, vSAN Enterprise, NSX Data Center Enterprise plus, vRealize Suite Enterprise, vRealize Network Insight Enterprise, and SDDC Manager.
- Cloud Foundation for VDI includes SDDC Manager for Desktop and NSX Data Center Advanced or Enterprise plus for Desktop, and it comes with or without Horizon Enterprise.
Configuration note: vCenter Server that is required for Cloud Foundation is licensed separately; only one vCenter Server license is required for all vCenter Servers deployed in a Cloud Foundation system.
The following table lists ordering information for the VMware Cloud Foundation License and Subscription options.
Description | Part number | Feature code |
---|---|---|
VMware Cloud Foundation Basic | ||
VMware Cloud Foundation Basic (Per CPU) w/1Yr Subscription and Support | 7S0600D0WW | S1RQ |
VMware Cloud Foundation Basic (Per CPU) w/3Yr Subscription and Support | 7S0600D1WW | S1RR |
VMware Cloud Foundation Basic (Per CPU) w/5Yr Subscription and Support | 7S0600D2WW | S1RS |
VMware Cloud Foundation Standard | ||
VMware Cloud Foundation Standard (Per CPU) w/1Y Subscription and Support | 7S0600DMWW | S1SB |
VMware Cloud Foundation Standard (Per CPU) w/3Y Subscription and Support | 7S0600DNWW | S1SC |
VMware Cloud Foundation Standard (Per CPU) w/5Y Subscription and Support | 7S0600DPWW | S1SD |
VMware Cloud Foundation Advanced | ||
VMware Cloud Foundation Advanced (Per CPU) w/1Y Subscription and Support | 7S0600DQWW | S1SE |
VMware Cloud Foundation Advanced (Per CPU) w/3Y Subscription and Support | 7S0600DRWW | S1SF |
VMware Cloud Foundation Advanced (Per CPU) w/5Y Subscription and Support | 7S0600DSWW | S1SG |
VMware Cloud Foundation Enterprise | ||
VMware Cloud Foundation Enterprise (Per CPU) w/1Y Subscription and Support | 7S0600DTWW | S1SH |
VMware Cloud Foundation Enterprise (Per CPU) w/3Y Subscription and Support | 7S0600DUWW | S1SJ |
VMware Cloud Foundation Enterprise (Per CPU) w/5Y Subscription and Support | 7S0600DVWW | S1SK |
VMware Cloud Foundation for VDI with NSX Data Center Advanced and Horizon Enterprise | ||
VCF for VDI: SDDC Mgr, NSX DC ADV, and Horizon ENT 10 pack (Per CCU) w/1Y S&S | 7S0600D6WW | S1RW |
VCF for VDI: SDDC Mgr, NSX DC ADV, and Horizon ENT 10 pack (Per CCU) w/3Y S&S | 7S0600D7WW | S1RX |
VCF for VDI: SDDC Mgr, NSX DC ADV, and Horizon ENT 10 pack (Per CCU) w/5Y S&S | 7S0600D8WW | S1RY |
VCF for VDI: SDDC Mgr, NSX DC ADV, and Horizon ENT 100 pack (Per CCU) w/1Y S&S | 7S0600D3WW | S1RT |
VCF for VDI: SDDC Mgr, NSX DC ADV, and Horizon ENT 100 pack (Per CCU) w/3Y S&S | 7S0600D4WW | S1RU |
VCF for VDI: SDDC Mgr, NSX DC ADV, and Horizon ENT 100 pack (Per CCU) w/5Y S&S | 7S0600D5WW | S1RV |
VMware Cloud Foundation for VDI with NSX Data Center Advanced (no Horizon included) | ||
VCF for VDI: SDDC Mgr and NSX DC ADV w/o Horizon ENT 10 pack (per CCU) w/1Y S&S | 7S0600DCWW | S1S2 |
VCF for VDI: SDDC Mgr and NSX DC ADV w/o Horizon ENT 10 pack (per CCU) w/3Y S&S | 7S0600DDWW | S1S3 |
VCF for VDI: SDDC Mgr and NSX DC ADV w/o Horizon ENT 10 pack (per CCU) w/5Y S&S | 7S0600DEWW | S1S4 |
VCF for VDI: SDDC Mgr and NSX DC ADV w/o Horizon ENT 100 pack (per CCU) w/1Y S&S | 7S0600D9WW | S1RZ |
VCF for VDI: SDDC Mgr and NSX DC ADV w/o Horizon ENT 100 pack (per CCU) w/3Y S&S | 7S0600DAWW | S1Z7 |
VCF for VDI: SDDC Mgr and NSX DC ADV w/o Horizon ENT 100 pack (per CCU) w/5Y S&S | 7S0600DBWW | S1Z8 |
VMware Cloud Foundation for VDI with NSX Data Center Enterprise plus (no Horizon included) | ||
VCF for VDI: SDDC Mgr and NSX DC ENT+ w/o Horizon ENT 10 pack (Per CCU) w/1Y S&S | 7S0600DJWW | S1S8 |
VCF for VDI: SDDC Mgr and NSX DC ENT+ w/o Horizon ENT 10 pack (Per CCU) w/3Y S&S | 7S0600DKWW | S1S9 |
VCF for VDI: SDDC Mgr and NSX DC ENT+ w/o Horizon ENT 10 pack (Per CCU) w/5Y S&S | 7S0600DLWW | S1SA |
VCF for VDI: SDDC Mgr and NSX DC ENT+ w/o Horizon ENT 100 pack (Per CCU) w/1Y S&S | 7S0600DFWW | S1S5 |
VCF for VDI: SDDC Mgr and NSX DC ENT+ w/o Horizon ENT 100 pack (Per CCU) w/3Y S&S | 7S0600DGWW | S1S6 |
VCF for VDI: SDDC Mgr and NSX DC ENT+ w/o Horizon ENT 100 pack (Per CCU) w/5Y S&S | 7S0600DHWW | S1S7 |
VMware vCenter Server
VMware vCenter Server provides centralized management of vSphere environments to simplify day-to-day operations and reduce the complexity of managing virtual infrastructure.
vCenter Server is required for managing ThinkAgile VX Certified Nodes. The nodes can be added to an existing installation of vCenter Server, or the software license for the vCenter Server instance can be purchased from Lenovo by selecting one the following License and Subscription options:
- VMware vCenter Server 6 Foundation for vSphere 6 (Per Instance) (manages up to 4 hosts)
- VMware vCenter Server 6 Standard for vSphere 6 (Per Instance) (unlimited hosts)
The vCenter Server licenses purchased from Lenovo include one, three, or five years of support and subscription.
The following table lists ordering information for the VMware vCenter License and Subscription options.
Description | Part number | Feature code |
---|---|---|
vCenter Server Foundation | ||
VMware vCenter Srv 6 Fdn for vSph 6 (Per Instance) w/1Yr Support | 7S06000DWW | B27S |
VMware vCenter Srv 6 Fdn for vSph 6 (Per Instance) w/3Yr Support | 7S06003PWW | B2B2 |
VMware vCenter Srv 6 Fdn for vSph 6 (Per Instance) w/5Yr Support | 7S06006ZWW | B2EC |
vCenter Server Standard | ||
VMware vCenter Srv 6 Std for vSph 6 (Per Instance) w/1Yr Support | 7S06000CWW | B27R |
VMware vCenter Srv 6 Std for vSph 6 (Per Instance) w/3Yr Support | 7S06003NWW | B2B1 |
VMware vCenter Srv 6 Std for vSph 6 (Per Instance) w/5Yr Support | 7S06006YWW | B2EB |
VMware vCenter Server offers the following key features:
- Centralized management of virtualized hosts and virtual machines from a single console.
- Centralized inventory of virtual machines, hosts, datastores and networks.
- Alerts and notifications can trigger automated workflows to remedy and preempt problems.
- Host profiles standardize and simplify configuration and management of VMware ESXi hosts.
- Resource management for virtual machines allows to control allocation of processor, memory, disk and network resources.
- Continuously monitors utilization across resource pools and intelligently allocates available resources among virtual machines according to predefined rules
- Automatically restarts virtual machines that have failed without manual intervention with VMware vSphere HA.
- Maintains records of significant configuration changes and exports reports for event tracking.
- Patch management enforces compliance to patch standards through automated scanning and patching of online ESXi hosts and select Microsoft and Linux virtual machines.
Systems management
The ThinkAgile VX 1SE Certified Nodes support the following systems management tools:
- Lenovo XClarity Controller
- Lenovo XClarity Administrator and XClarity Pro
- Lenovo XClarity Integrator for VMware vCenter
- Lenovo XClarity Energy Manager
Lenovo XClarity Controller
The ThinkAgile VX 1SE Certified Nodes contain Lenovo XClarity Controller (XCC), which provides advanced service-processor control, monitoring, and alerting functions. XClarity Controller offers three functional levels: Standard, Advanced, and Enterprise.
By default, the VX Certified Nodes include XClarity Controller Standard features, and they can be configured for Advanced or Enterprise functionality by using the Features on Demand (FoD) upgrades.
XClarity Controller Standard offers the following capabilities:
- Gathering and viewing system information and inventory
- Monitoring system status and health
- Alerting and notifications
- Event logging
- Configuring network connectivity
- Configuring security
- Updating system firmware
- Configuring server settings and devices
- Real-time power usage monitoring
- Remotely controlling server power (Power on, Power off, Restart)
- Managing FoD activation keys
- Redirecting serial console via IPMI
- Capturing the video display contents when an operating system hang condition is detected
XClarity Controller Advanced Upgrade adds the following functionality to the Standard features:
- Remotely viewing video with the following graphics resolutions:
- Up to 1600x1200 with up to 23 bits per pixel; or
- Up to 1920x1200 with up to 15 bits per pixel
- Remotely accessing the server using the keyboard and mouse from a remote client
- Remotely deploying an operating system
- Syslog alerting
- Redirecting serial console via SSH
- Displaying graphics for real-time and historical power usage data and temperature
XClarity Controller Enterprise Upgrade adds the following functionality to the Advanced features:
- Capping power usage
- Mapping the ISO and image files located on the local client as virtual drives for use by the server
- Mounting the remote ISO and image files via HTTPS, SFTP, CIFS, and NFS
- Collaborating across up to six users of the virtual console
- Controlling quality and bandwidth usage
The XClarity Controller provides remote server management through the following interfaces:
- Intelligent Platform Management Interface (IPMI) Version 2.0
- Simple Network Management Protocol (SNMP) Version 3
- Common Information Model (CIM)
- Data Center Manageability Interface (DCMI) Version 1.5
- Redfish REpresentational State Transfer (REST) API
- Web browser with HTML5 support
- Command-line interface
- Virtual Operator Panel with XClarity Mobile App via the front USB port with XClarity Controller access
Virtual Operator Panel provides quick access to system status, firmware, network, health, and alerts information. With proper authentication, it also allows to configure systems management and network settings and to control system power (Power on, Power off, Restart). The Virtual Operator Panel can be accessed from the XClarity Mobile App running on the Android or iOS mobile device that is connected to the front USB port with XClarity Controller access (See Components and connectors).
The following table lists the XClarity Controller FoD upgrades.
Description | Part number | Feature code | Maximum quantity |
---|---|---|---|
ThinkSystem XClarity Controller Standard to Advanced Upgrade | 4L47A09132 | AVUT | 1 |
ThinkSystem XClarity Controller Standard to Enterprise Upgrade | None* | AUPW | 1 |
ThinkSystem XClarity Controller Advanced to Enterprise Upgrade | 4L47A09133 | None** | 1 |
* Factory-installed only.
** Field-upgrade only.
Configuration notes:
- For factory-installed upgrades, either Standard to Advanced Upgrade (feature AVUT) or Standard to Enterprise Upgrade (feature AUPW) can be selected, but not both.
- For field upgrades, the Advanced to Enterprise Upgrade (4L47A09133) requires the Standard to Advanced Upgrade to be activated on the server previously with either the factory-installed feature AVUT or field upgrade 4L47A09132.
Lenovo XClarity Administrator and XClarity Pro
Lenovo XClarity Administrator is a centralized systems management solution that helps administrators deliver infrastructure faster. This solution integrates easily with Lenovo x86 servers, appliances, certified nodes, Top-of-Rack Ethernet switches, and storage systems, providing automated agent-less discovery, inventory, monitoring, and alerts across multiple systems. In addition, some managed endpoints support firmware updates and configuration management.
Lenovo XClarity Administrator is an optional software component for managing ThinkAgile VX Certified Nodes which can be downloaded and used at no charge to discover and monitor the nodes and manage firmware upgrades for them.
If software support is required for XClarity Administrator and XClarity Integrator for vCenter, Lenovo XClarity Pro software subscription should be ordered. Lenovo XClarity Pro is licensed on a per managed system basis, that is, each managed Lenovo system requires a license.
The following table lists the geo-specific Lenovo XClarity software license options.
Description | Part number (NA, AP, Japan)* |
Part number (EMEA, LA)** |
---|---|---|
Lenovo XClarity Pro, per Managed Endpoint w/1 Yr SW S&S | 00MT201 | 00MT207 |
Lenovo XClarity Pro, per Managed Endpoint w/3 Yr SW S&S | 00MT202 | 00MT208 |
Lenovo XClarity Pro, per Managed Endpoint w/5 Yr SW S&S | 00MT203 | 00MT209 |
* NA = North America; AP = Asia Pacific.
** EMEA = Europe, Middle East, Africa; LA = Latin America.
Lenovo XClarity Administrator offers the following standard features that are available at no charge:
- Auto-discovery and monitoring of VX Certified Nodes
- Firmware updates and compliance enforcement
- External alerts and notifications via SNMP traps, syslog remote logging, and e-mail
- Secure connections to managed endpoints
- NIST 800-131A or FIPS 140-2 compliant cryptographic standards between the management solution and managed endpoints
- Integration into existing higher-level management systems such as cloud automation and orchestration tools through REST APIs, providing extensive external visibility and control over hardware resources
- An intuitive, easy-to-use GUI
- Scripting with Windows PowerShell, providing command-line visibility and control over hardware resources
Lenovo XClarity Administrator offers the following premium features that require an optional Pro license:
- Pattern-based configuration management that allows to define configurations once and apply repeatedly without errors when deploying new servers or redeploying existing servers without disrupting the fabric
- Bare-metal deployment of operating systems and hypervisors to streamline infrastructure provisioning
For more information, refer to the Lenovo XClarity Administrator Product Guide:
http://lenovopress.com/tips1200
Lenovo XClarity Integrator for VMware vCenter
Lenovo XClarity Integrator for VMware vCenter is a software plug-in module for Lenovo XClarity Administrator that allows administrators to manage physical infrastructure from leading external virtualization management software tool from VMware.
Lenovo XClarity Integrator for VMware vCenter offers the following features:
- Ability to discover, manage, and monitor Lenovo node hardware from the virtualization management tool
- Deployment of firmware updates to VX Certified Nodes from the virtualization management tool
- Non-disruptive server maintenance in clustered environments that reduces workload downtime by dynamically migrating workloads from affected hosts during rolling server updates or reboots
- Greater service level uptime and assurance in clustered environments during unplanned hardware events by dynamically triggering workload migration from impacted hosts when impending hardware failures are predicted
Lenovo XClarity Integrator for VMware vCenter can be downloaded and used at no charge. For more information, refer to the Lenovo XClarity Integrator for VMware vCenter web page:
https://support.lenovo.com/us/en/solutions/lnvo-vmware
Lenovo XClarity Energy Manager
Lenovo XClarity Energy Manager provides a stand-alone, web-based agent-less power management console that provides real time data and enables you to observe, plan and manage power and cooling for Lenovo servers, appliances, and certified nodes. Using built-in intelligence, XClarity Energy Manager identifies server power consumption trends and ideal power settings, and it performs cooling analysis so that customers can define and optimize their power-saving policies.
Lenovo XClarity Energy Manager offers the following capabilities:
- Monitors room, row, rack, and device levels in the data center
- Reports vital system information, such as power, temperature and resource utilization
- Monitors inlet temperature to locate hot spots, reducing the risk of data or device damage
- Provides finely-grained controls to limit platform power in compliance with IT policy
- Generates alerts when a user-defined threshold is reached
Lenovo XClarity Energy Manager is an optional software component for VX Certified Nodes that is licensed on a per managed node basis, that is, each managed system requires a license. The 1-node Energy Manager license is included in the XClarity Controller Enterprise upgrade.
To manage systems without XClarity Controller Enterprise licenses, a node license pack should be purchased. The following table lists the geo-specific Lenovo XClarity Energy Manager software license options.
Description | Part number (NA, AP, Japan)* |
Part number (EMEA, LA)** |
---|---|---|
Lenovo XClarity Energy Manager, 1 Node w/ 1 Yr S&S | 01DA225 | 01DA228 |
* NA = North America; AP = Asia Pacific.
** EMEA = Europe, Middle East, Africa; LA = Latin America.
For more information, refer to the Lenovo XClarity Energy Manager web page:
http://datacentersupport.lenovo.com/us/en/solutions/lnvo-lxem
Physical specifications
The ThinkAgile VX 1SE Certified Nodes have the following dimensions and weight (approximate):
- Height: 43 mm (1.7 in)
- Width: 434 mm (17.1 in)
- Depth: 498 mm (19.6 in)
- Weight (maximum): 12.3 kg (27.1 lb)
Operating environment
The ThinkAgile VX 1SE Certified Node complies with ASHRAE class A2 specifications. The node performance might be impacted when the operating temperature is outside the ASHRAE A2 specifications or in case of a system fan failure. Depending on the hardware configuration, some node configurations comply with ASHRAE class A3 specifications. To comply with ASHRAE class A3 specifications, the ThinkAgile VX 1SE Certified Nodes must be configured with 8x 2.5-inch hot-swap drive bays and a processor of up to 80 W TDP.
The ThinkAgile VX 1SE Certified Node is supported in the following environment:
- Air temperature:
- Operating:
- ASHRAE Class A3: 5 °C - 40 °C (41 °F - 104 °F); for altitudes above 900 m (2,953 ft), decrease the maximum ambient temperature by 1 °C for every 175-m (574-ft) increase in altitude
- ASHRAE Class A2: 10 °C - 35 °C (50 °F - 95 °F); for altitudes above 900 m (2,953 ft), decrease the maximum ambient temperature by 1 °C for every 300-m (984-ft) increase in altitude
- Non-operating: 5 °C - 45 °C (41 °F - 113 °F)
- Storage: -40 °C - +60 °C (-40 °F - 140 °F)
- Operating:
- Maximum altitude: 3050 m (10,000 ft)
- Humidity:
- Operating:
- ASHRAE Class A3: 8% - 85% (non-condensing); maximum dew point: 24 °C (75 °F)
- ASHRAE Class A2: 8% - 80% (non-condensing); maximum dew point: 21 °C (70 °F)
- Storage: 8% - 90% (non-condensing)
- Operating:
- Electrical:
- 100 - 127 (nominal) V AC; 50 Hz / 60 Hz
- 200 - 240 (nominal) V AC; 50 Hz / 60 Hz
- Acoustics:
- Minimum configuration:
- Operating: 5.3 bels
- Idle: 4.9 bels
- Maximum configuration:
- Operating: 5.7 bels
- Idle: 5.4 bels
- Minimum configuration:
- Vibration:
- Operating: 0.21 G rms at 5 Hz to 500 Hz for 15 minutes across 3 axes
- Non-operating: 1.04 G rms at 2 Hz to 200 Hz for 15 minutes across 6 surfaces
- Shock:
- Operating: 15 G for 3 milliseconds in each direction (positive and negative X, Y, and Z axes)
- Non-operating: 50 G for 152 in./sec velocity change across 6 surfaces
The following table lists the maximum system power load, rated inlet current, and system heat output based on the power supply and source voltage.
Power supply | Source voltage | Maximum power load per system |
Rated current per inlet |
System heat output |
---|---|---|---|---|
300 W Gold (One power supply) |
100 - 127 V AC | 334 W | 4 A | 1139 BTU/hour |
200 - 240 V AC | 326 W | 2 A | 1111 BTU/hour | |
450 W Platinum (Two power supplies) |
100 - 127 V AC | 503 W | 5.8 A | 1717 BTU/hour |
200 - 240 V AC | 484 W | 2.9 A | 1650 BTU/hour |
Regulatory compliance
The ThinkAgile VX 1SE Certified Nodes conform to the following regulations:
- United States FCC Title 47 CFR Part 15 Subpart B
- Canada ICES-003/NMB-03, Class A
- UL62368-1
- Mexico NOM-019
- Argentina IEC60950-1
- Japan VCCI, Class A
- Australia/New Zealand AS/NZS CISPR 32, Class A
- China CCC GB4943.1, GB9254 Class A, GB17625.1, CECP, CELP
- Taiwan BSMI CNS13438, Class A; CNS14336-1; CNS15663
- Korea KN32, Class A; KN35
- Russia, Belorussia, and Kazakhstan TR CU 020/2011 and TR CU 004/2011
- IEC 60950-1, IEC 62368-1 (CB Certificate and CB Test Report)
- Europe CE Mark (EN55032 Class A, EN60950-1, EN55024, EN50581, EN61000-3-2, EN61000-3-3, EN62368-1)
- CISPR 32, Class A
- Germany TUV-GS (EK1-ITB2000, EN62368-1)
- Reduction of Hazardous Substances (ROHS)
Warranty and support
The ThinkAgile VX Certified Nodes can be configured with a three-, four, or five-year hardware warranty and various levels of service coverage with a well-defined scope of services, including service hours, response time, term of service, and service agreement terms and conditions.
The base warranty provides 9x5 Next Business Day response with parts delivered. Lenovo’s additional support services provide a sophisticated, unified support structure for a customer's data center, with an experience consistently ranked number one in customer satisfaction worldwide.
The following Lenovo support services are available for selection:
- Warranty service level upgrades (Preconfigured Support) are available to meet the on-site response time targets that match the criticality of customer's systems:
- 3, 4, or 5 years of service coverage.
- 1-year or 2-year post-warranty extensions.
- Foundation Service: 9x5 service coverage with next business day onsite response, with optional YourDrive YourData.
- Essential Service: 24x7 service coverage with 4-hour onsite response or 24-hour committed repair (available only in select regions), bundled with YourDrive YourData.
- Advanced Service: 24x7 service coverage with 2-hour onsite response or 6-hour committed repair (available only in select regions), bundled with YourDrive YourData.
- Managed Services
Lenovo Managed Services provide continuous 24x7 remote monitoring (plus 24x7 call center availability) and proactive management of a customer's data center using state of the art tools, systems, and practices by a team of highly skilled and experienced Lenovo services professionals.
Quarterly reviews check error logs, verify firmware and operating system device driver levels, and software as needed. Lenovo will also maintain records of latest patches, critical updates, and firmware levels, to ensure customer's systems are providing business value through optimized performance.
- Technical Account Management (TAM)
A Lenovo Technical Account Manager helps customers optimize operations of their data centers based on a deep understanding of customer's business. Customers gain direct access to a Lenovo TAM, who serves as their single point of contact to expedite service requests, provide status updates, and furnish reports to track incidents over time. Also, a TAM helps proactively make service recommendations and manage service relationship with Lenovo to make certain that customer's needs are met.
- Enterprise Software Support
Lenovo Enterprise Software Support is an additional support service that provides customers with software support on Microsoft, Red Hat, SUSE, and VMWare applications and systems. Around the clock availability for critical problems plus unlimited calls and incidents helps customers address challenges fast, without incremental costs. Support staff can answer troubleshooting and diagnostic questions, address product compatibility and interoperability issues, isolate causes of problems, report defects to software vendors, and more.
- YourDrive YourData
Lenovo’s YourDrive YourData service is a multi-drive retention offering that ensures that customer's data is always under their control, regardless of the number of drives that are installed in their Lenovo server. In the unlikely event of a drive failure, customers retain possession of their drive while Lenovo replaces the failed drive part. Customer's data stays safely on customer premises, in their hands. The YourDrive YourData service can be purchased in convenient bundles with Foundation, Essential, or Advanced services.
- Health Check
Having a trusted partner who can perform regular and detailed health checks is central to maintaining efficiency and ensuring that customer systems and business are always running at their best. Health Check supports Lenovo-branded server, storage, and networking devices, as well as select Lenovo-supported products from other vendors that are sold by Lenovo or a Lenovo-Authorized Reseller.
Some regions might have different warranty terms and conditions than the standard warranty. This is due to local business practices or laws in the specific region. Local service teams can assist in explaining region-specific terms when needed. Examples of region-specific warranty terms are second or longer business day parts delivery or parts-only base warranty.
If warranty terms and conditions include onsite labor for repair or replacement of parts, Lenovo will dispatch a service technician to the customer site to perform the replacement. Onsite labor under base warranty is limited to labor for replacement of parts that have been determined to be field-replaceable units (FRUs). Parts that are determined to be customer-replaceable units (CRUs) do not include onsite labor under base warranty.
If warranty terms include parts-only base warranty, Lenovo is responsible for delivering only replacement parts that are under base warranty (including FRUs) that will be sent to a requested location for self-service. Parts-only service does not include a service technician being dispatched onsite. Parts must be changed at customer’s own cost and labor and defective parts must be returned following the instructions supplied with the spare parts.
Lenovo support services are region-specific. Not all support services are available in every region. For information about Lenovo support services that are available in a specific region, refer to the following resources:
- Service part numbers in Data Center Solution Configurator (DCSC):
http://dcsc.lenovo.com/#/services - Lenovo Services Availability Locator
https://lenovolocator.com/
For service definitions, region-specific details, and service limitations, refer to the following documents:
- Lenovo Statement of Limited Warranty for Infrastructure Solutions Group (ISG) Servers and System Storage
http://pcsupport.lenovo.com/us/en/solutions/ht503310 - Lenovo Data Center Services Agreement
http://support.lenovo.com/us/en/solutions/ht116628
Software maintenance
For the VMware software and subscription licenses provided by the customer, software support that is provided by VMware is based on the support level included with these licenses.
Lenovo offers optional one-, three-, or five-year VMware software support and subscription for ThinkAgile VX Certified Nodes that entitles customers to submit service requests to troubleshoot VMware software issues and receive code updates, including fixes, patches, and new software releases.
For the VMware vSphere, vSAN, and vCenter Server software and subscription licenses purchased from Lenovo together with the ThinkAgile VX Certified Nodes, software support that is provided by VMware includes Production-level support with 24x7 phone and web coverage with the following target response times (priorities are defined by VMware based on the impact on productivity):
- Severity 1 (Critical: Substantial loss or disruption of service, significant risk of data loss): 30 minutes
- Severity 2 (Major: Operations are severely constrained, significant impact): 4 business hours
- Severity 3 (Minor: Non-critical loss of functionality, minimal impact): 8 business hours
- Severity 4 (Cosmetic: General questions): 12 business hours
Deployment services
The following optional Lenovo basic installation services are available for the ThinkAgile VX Certified Nodes:
- Unpacking and inspecting the systems
- Mounting the systems in a rack cabinet
- Connecting the systems to electrical power and network
- Checking and updating firmware to the latest levels
- Verifying operations
- Disposal of the packaging materials (within the customer site)
The following optional Lenovo deployment services are available for the ThinkAgile VX Certified Nodes to get customers up and running quickly:
- Conducting remote preparation and planning
- Verifying firmware versions and performing firmware updates, if needed
- Configuring XCC management settings
- Configuring hypervisor settings
- Configuring vSAN
- Configuring VMware vCenter Server and discovering hosts and storage
- Configuring Lenovo XClarity network settings and performing discovery and inventory
- Transferring knowledge
- Developing post-installation documentation
For more information, refer to the Data Center Deployment Services web page:
http://www.lenovo.com/us/en/data-center/services/deployment
Ethernet LAN switches
The following table lists the Ethernet LAN switches that are offered by Lenovo that can be used with the ThinkAgile VX 1SE Certified Nodes for network connectivity.
Description | Part number |
---|---|
1 Gb Ethernet switches (Out-of-band hardware management or 1 GbE host connectivity) | |
Lenovo ThinkSystem NE0152T RackSwitch (Rear to Front) | 7Y810011WW |
Lenovo ThinkSystem NE0152TO RackSwitch (Rear to Front, ONIE) | 7Z320O11WW |
Lenovo RackSwitch G7028 (Rear to Front) | 7159BAX |
Lenovo RackSwitch G7052 (Rear to Front) | 7159CAX |
Lenovo CE0128TB Switch (3-Year Warranty) | 7Z340011WW |
Lenovo CE0128TB Switch (Limited Lifetime Warranty) | 7Z360011WW |
Lenovo CE0128PB Switch (3-Year Warranty) | 7Z340012WW |
Lenovo CE0128PB Switch (Limited Lifetime Warranty) | 7Z360012WW |
Lenovo CE0152TB Switch (3-Year Warranty) | 7Z350021WW |
Lenovo CE0152TB Switch (Limited Lifetime Warranty) | 7Z370021WW |
Lenovo CE0152PB Switch (3-Year Warranty) | 7Z350022WW |
Lenovo CE0152PB Switch (Limited Lifetime Warranty) | 7Z370022WW |
10 Gb Ethernet switches (10 GbE host connectivity) | |
Lenovo ThinkSystem NE1032 RackSwitch (Rear to Front) | 7159A1X |
Lenovo ThinkSystem NE1032T RackSwitch (Rear to Front) | 7159B1X |
Lenovo ThinkSystem NE1064TO RackSwitch (Rear to Front, ONIE) | 7Z330O11WW |
Lenovo ThinkSystem NE1072T RackSwitch (Rear to Front) | 7159C1X |
Lenovo RackSwitch G8272 (Rear to Front) | 7159CRW |
25 Gb Ethernet switches (25 GbE host connectivity) | |
Lenovo ThinkSystem NE2572 RackSwitch (Rear to Front) | 7159E1X |
Lenovo ThinkSystem NE2572O RackSwitch (Rear to Front, ONIE) | 7Z210O21WW |
Lenovo ThinkSystem NE2580O RackSwitch (Rear to Front, ONIE) | 7Z330O21WW |
100 Gb Ethernet switches (40 GbE/100 GbE aggregation layer; 10 GbE/25 GbE breakout host connectivity) | |
Lenovo ThinkSystem NE10032 RackSwitch (Rear to Front) | 7159D1X |
Lenovo ThinkSystem NE10032O RackSwitch (Rear to Front, ONIE) | 7Z210O11WW |
For more information, see the list of Product Guides in the Top-of-rack Switches category:
http://lenovopress.com/servers/options/switches#rt=product-guide
Rack cabinets
The following table lists the rack cabinets that are currently offered by Lenovo that can be used for mounting the ThinkAgile VX 1SE Certified Nodes and other IT infrastructure building blocks.
Description | Part number |
---|---|
12U 1200mm Deep Micro Datacenter Rack (no sidewall compartments), 1YR Warranty | 7D2B0001WW |
12U 1200mm Deep Micro Datacenter Rack (no sidewall compartments), 3YR Warranty | 7D2N0001WW |
18U 1200mm Deep Micro Datacenter Rack (no sidewall compartments), 1YR Warranty | 7D2C0001WW |
18U 1200mm Deep Micro Datacenter Rack (no sidewall compartments), 3YR Warranty | 7D2P0001WW |
25U S2 Standard Rack (1000 mm deep; 2 sidewall compartments) | 93072RX |
25U Static S2 Standard Rack (1000 mm deep; 2 sidewall compartments) | 93072PX |
42U S2 Standard Rack (1000 mm deep; 6 sidewall compartments) | 93074RX |
42U 1100mm Enterprise V2 Dynamic Rack (6 sidewall compartments) | 93634PX |
42U 1100mm Enterprise V2 Dynamic Expansion Rack (6 sidewall compartments) | 93634EX |
42U 1200mm Deep Dynamic Rack (6 sidewall compartments) | 93604PX |
42U 1200mm Deep Static Rack (6 sidewall compartments) | 93614PX |
42U Enterprise Rack (1105 mm deep; 4 sidewall compartments) | 93084PX |
42U Enterprise Expansion Rack (1105 mm deep; 4 sidewall compartments) | 93084EX |
For more information, see the list of Product Guides in the Rack Cabinets category:
http://lenovopress.com/servers/options/racks#rt=product-guide
Power distribution units
The following table lists the power distribution units (PDUs) that are currently offered by Lenovo that can be used for distributing electrical power to the ThinkAgile VX 1SE Certified Nodes and other IT infrastructure building blocks mounted in a rack cabinet.
Description | Part number |
---|---|
0U Basic PDUs | |
0U 36 C13/6 C19 24A/200-240V 1 Phase PDU with NEMA L6-30P line cord | 00YJ776 |
0U 36 C13/6 C19 32A/200-240V 1 Phase PDU with IEC60309 332P6 line cord | 00YJ777 |
0U 21 C13/12 C19 32A/200-240V/346-415V 3 Phase PDU with IEC60309 532P6 cord | 00YJ778 |
0U 21 C13/12 C19 48A/200-240V 3 Phase PDU with IEC60309 460P9 line cord | 00YJ779 |
Switched and Monitored PDUs | |
0U 20 C13/4 C19 Switched and Monitored 24A/200-240V/1Ph PDU w/ NEMA L6-30P cord | 00YJ781 |
0U 20 C13/4 C19 Switched and Monitored 32A/200-240V/1Ph PDU w/ IEC60309 332P6 cord | 00YJ780 |
0U 18 C13/6 C19 Switched and Monitored 32A/200-240/346-415V/3Ph PDU w/ IEC60309 532P6 cord | 00YJ782 |
0U 12 C13/12 C19 Switched and Monitored 48A/200-240V/3Ph PDU w/ IEC60309 460P9 cord | 00YJ783 |
1U 9 C19/3 C13 Switched and Monitored DPI PDU (without line cord) | 46M4002 |
1U 9 C19/3 C13 Switched and Monitored 60A 3Ph PDU with IEC 309 3P+Gnd cord | 46M4003 |
1U 12 C13 Switched and Monitored DPI PDU (without line cord) | 46M4004 |
1U 12 C13 Switched and Monitored 60A 3 Phase PDU with IEC 309 3P+Gnd line cord | 46M4005 |
Ultra Density Enterprise PDUs (9x IEC 320 C13 + 3x IEC 320 C19 outlets) | |
Ultra Density Enterprise C19/C13 PDU Module (without line cord) | 71762NX |
Ultra Density Enterprise C19/C13 PDU 60A/208V/3ph with IEC 309 3P+Gnd line cord | 71763NU |
C13 Enterprise PDUs (12x IEC 320 C13 outlets) | |
DPI C13 Enterprise PDU+ (without line cord) | 39M2816 |
DPI Single Phase C13 Enterprise PDU (without line cord) | 39Y8941 |
C19 Enterprise PDUs (6x IEC 320 C19 outlets) | |
DPI Single Phase C19 Enterprise PDU (without line cord) | 39Y8948 |
DPI 60A 3 Phase C19 Enterprise PDU with IEC 309 3P+G (208 V) fixed line cord | 39Y8923 |
Front-end PDUs (3x IEC 320 C19 outlets) | |
DPI 30amp/125V Front-end PDU with NEMA L5-30P line cord | 39Y8938 |
DPI 30amp/250V Front-end PDU with NEMA L6-30P line cord | 39Y8939 |
DPI 32amp/250V Front-end PDU with IEC 309 2P+Gnd line cord | 39Y8934 |
DPI 60amp/250V Front-end PDU with IEC 309 2P+Gnd line cord | 39Y8940 |
DPI 63amp/250V Front-end PDU with IEC 309 2P+Gnd line cord | 39Y8935 |
Universal PDUs (7x IEC 320 C13 outlets) | |
DPI Universal 7 C13 PDU (with 2 m IEC 320-C19 to C20 rack power cord) | 00YE443 |
Line cords for PDUs that ship without a line cord | |
DPI 30a Line Cord (NEMA L6-30P) | 40K9614 |
DPI 32a Line Cord (IEC 309 P+N+G) | 40K9612 |
DPI 32a Line Cord (IEC 309 3P+N+G) | 40K9611 |
DPI 60a Cord (IEC 309 2P+G) | 40K9615 |
DPI 63a Cord (IEC 309 P+N+G) | 40K9613 |
DPI Australian/NZ 3112 Line Cord (32A) | 40K9617 |
DPI Korean 8305 Line Cord (30A) | 40K9618 |
For more information, see the list of Product Guides in the Power Distribution Units category:
http://lenovopress.com/servers/options/pdu#rt=product-guide
Uninterruptible power supply units
The following table lists the uninterruptible power supply (UPS) units that are currently offered by Lenovo that can be used for providing electrical power protection to the ThinkAgile VX 1SE Certified Nodes and other IT infrastructure building blocks.
Description | Part number |
---|---|
Worldwide models | |
RT1.5kVA 2U Rack or Tower UPS (100-125VAC) (8x NEMA 5-15R 12A outlets) | 55941AX |
RT1.5kVA 2U Rack or Tower UPS (200-240VAC) (8x IEC 320 C13 10A outlets) | 55941KX |
RT2.2kVA 2U Rack or Tower UPS (100-125VAC) (8x NEMA 5-20R 16A outlets) | 55942AX |
RT2.2kVA 2U Rack or Tower UPS (200-240VAC) (8x IEC 320 C13 10A, 1x IEC 320 C19 16A outlets) | 55942KX |
RT3kVA 2U Rack or Tower UPS (100-125VAC) (6x NEMA 5-20R 16A, 1x NEMA L5-30R 24A outlets) | 55943AX |
RT3kVA 2U Rack or Tower UPS (200-240VAC) (8x IEC 320 C13 10A, 1x IEC 320 C19 16A outlets) | 55943KX |
RT5kVA 3U Rack or Tower UPS (200-240VAC) (8x IEC 320 C13 10A, 2x IEC 320 C19 16A outlets) | 55945KX |
RT6kVA 3U Rack or Tower UPS (200-240VAC) (8x IEC 320 C13 10A, 2x IEC 320 C19 16A outlets) | 55946KX |
RT8kVA 6U Rack or Tower UPS (200-240VAC) (4x IEC 320-C19 16A outlets) | 55948KX |
RT11kVA 6U Rack or Tower UPS (200-240VAC) (4x IEC 320-C19 16A outlets) | 55949KX |
RT8kVA 6U 3:1 Phase Rack or Tower UPS (380-415VAC) (4x IEC 320-C19 16A outlets) | 55948PX |
RT11kVA 6U 3:1 Phase Rack or Tower UPS (380-415VAC) (4x IEC 320-C19 16A outlets) | 55949PX |
ASEAN, HTK, INDIA, and PRC models | |
ThinkSystem RT3kVA 2U Standard UPS (200-230VAC) (2x C13 10A, 2x GB 10A, 1x C19 16A outlets) | 55943KT |
ThinkSystem RT3kVA 2U Long Backup UPS (200-230VAC) (2x C13 10A, 2x GB 10A, 1x C19 16A outlets) | 55943LT |
ThinkSystem RT6kVA 5U UPS (200-230VAC) (2x C13 10A outlets, 1x Terminal Block output) | 55946KT |
ThinkSystem RT10kVA 5U UPS (200-230VAC) (2x C13 10A outlets, 1x Terminal Block output) | 5594XKT |
For more information, see the list of Product Guides in the Uninterruptible Power Supply Units category:
http://lenovopress.com/servers/options/ups#rt=product-guide
Lenovo Financial Services
Lenovo Financial Services reinforces Lenovo’s commitment to deliver pioneering products and services that are recognized for their quality, excellence, and trustworthiness. Lenovo Financial Services offers financing solutions and services that complement your technology solution anywhere in the world.
We are dedicated to delivering a positive finance experience for customers like you who want to maximize your purchase power by obtaining the technology you need today, protect against technology obsolescence, and preserve your capital for other uses.
We work with businesses, non-profit organizations, governments and educational institutions to finance their entire technology solution. We focus on making it easy to do business with us. Our highly experienced team of finance professionals operates in a work culture that emphasizes the importance of providing outstanding customer service. Our systems, processes and flexible policies support our goal of providing customers with a positive experience.
We finance your entire solution. Unlike others, we allow you to bundle everything you need from hardware and software to service contracts, installation costs, training fees, and sales tax. If you decide weeks or months later to add to your solution, we can consolidate everything into a single invoice.
Our Premier Client services provide large accounts with special handling services to ensure these complex transactions are serviced properly. As a premier client, you have a dedicated finance specialist who manages your account through its life, from first invoice through asset return or purchase. This specialist develops an in-depth understanding of your invoice and payment requirements. For you, this dedication provides a high-quality, easy, and positive financing experience.
For your region-specific offers please ask your Lenovo sales representative or your technology provider about the use of Lenovo Financial Services. For more information, see the following Lenovo website:
http://www.lenovo.com/us/en/landingpage/lenovo-financial-services
Related product families
Product families related to this document are the following:
Trademarks
Lenovo and the Lenovo logo are trademarks or registered trademarks of Lenovo in the United States, other countries, or both. A current list of Lenovo trademarks is available on the Web at https://www.lenovo.com/us/en/legal/copytrade/.
The following terms are trademarks of Lenovo in the United States, other countries, or both:
Lenovo®
AnyBay®
ThinkAgile®
ThinkSystem®
XClarity®
The following terms are trademarks of other companies:
Intel® and Xeon® are trademarks of Intel Corporation or its subsidiaries.
Linux® is the trademark of Linus Torvalds in the U.S. and other countries.
Microsoft®, PowerShell, SQL Server®, SharePoint®, Skype®, Windows PowerShell®, and Windows® are trademarks of Microsoft Corporation in the United States, other countries, or both.
Other company, product, or service names may be trademarks or service marks of others.