skip to main content

Lenovo ThinkSystem DM7100F Unified All Flash Storage Array

Product Guide

Home
Top

Abstract

Lenovo ThinkSystem DM7100F is a scalable, unified, all flash storage system that is designed to provide high performance, simplicity, capacity, security, and high availability for large enterprises. Powered by the ONTAP software, ThinkSystem DM7100F delivers enterprise-class storage management capabilities with a wide choice of host connectivity options, flexible drive configurations, and enhanced data management features.

This product guide provides essential technical and pre-sales information on the Lenovo ThinkSystem DM7100F Unified Flash Storage Array, its key features and specifications, components and options, and configuration guidelines.

This guide is intended for technical specialists, sales specialists, sales engineers, and IT architects who want to learn more about the ThinkSystem DM7100F Unified Flash Storage Array and consider its use in their solutions.

Change History

Changes in the September 17, 2024 update:

  • Added the following drive options under Drives section
    • Lenovo ThinkSystem 3.84TB (2x 1.9TB NVMe SED) Drive Pack for DM7100F - Essential Bundle, C3X2
    • Lenovo ThinkSystem 7.68TB (2x 3.84TB NVMe SED) Drive Pack for DM7100F - Essential Bundle, C3XX
    • Lenovo ThinkSystem 15.4TB (2x 7.68TB NVMe SED) Drive Pack for DM7100F - Essential Bundle, C3XW
    • Lenovo ThinkSystem 30.7TB (2x 15.36TB NVMe SED) Drive Pack for DM7100F - Essential Bundle, C3XV
    • Lenovo ThinkSystem 3.84TB (2x 1.9TB NVMe SED) Drive Pack for DM7100F - Complete Bundle, C3XU
    • Lenovo ThinkSystem 7.68TB (2x 3.84TB NVMe SED) Drive Pack for DM7100F - Complete Bundle, C3XT
    • Lenovo ThinkSystem 15.4TB (2x 7.68TB NVMe SED) Drive Pack for DM7100F - Complete Bundle, C3XR
    • Lenovo ThinkSystem 30.7TB (2x 15.36TB NVMe SED) Drive Pack for DM7100F - Complete Bundle, C3XQ
    • Lenovo ThinkSystem 7.68TB (2x 3.84TB NVMe SED FIPS) Drive Pack for DM7100F - Complete Bundle, C3XS

Introduction

Lenovo ThinkSystem DM7100F is a scalable, unified, all flash storage system that is designed to provide high performance, simplicity, capacity, security, and high availability for large enterprises. Powered by the ONTAP software, ThinkSystem DM7100F delivers enterprise-class storage management capabilities with a wide choice of host connectivity options, flexible drive configurations, and enhanced data management features, including end-to-end NVMe support (NVMe over Fabrics and NVMe drives). The DM7100F is a perfect fit for a wide range of enterprise workloads, including big data and analytics, artificial intelligence, engineering and design, hybrid clouds, and other storage I/O-intensive applications.

The ThinkSystem DM7100F 4U controller enclosure is shown in the following figure.

Lenovo ThinkSystem DM7100F
Figure 1. Lenovo ThinkSystem DM7100F

Up to 12 DM7100F Storage Arrays can be combined into a clustered system in a NAS environment, or up to 6 DM7100F Storage Arrays can be combined into a clustered system in a SAN environment.

Did you know?

The ThinkSystem DM7100F offers end-to-end NVMe storage connectivity with NVMe over Fabrics (NVMeOF) and NVMe drives by implementing NVMe/FC with 32 Gb Fibre Channel host interfaces.

A single ThinkSystem DM7100F scales up to 7.37 PB of raw storage capacity. A cluster of the DM7100F storage systems scales up to 88.4 PB for NAS or up to 44.2 PB for SAN environments.

The ThinkSystem DM7100F offers unified file and block storage connectivity, and it supports multiple storage protocols simultaneously with a choice of 1/10 GbE, 25 GbE, and 40/100 GbE NAS and iSCSI, 8/16/32 Gb Fibre Channel, and 32 Gb NVMe/FC.

Key features

A single ThinkSystem DM7100F Storage Array consists of the 4U rack-mount controller enclosure and one or more expansion enclosures. The controller enclosure includes two controllers, 256 GB RAM (128 GB RAM per controller), and 32 GB battery-backed NVRAM (16 GB NVRAM per controller). 25 GbE SFP28 NAS/iSCSI or 4/8/16 Gb Fibre Channel (FC) ports on the controller's mezzanine cards provide base host connectivity, with adapter card options for additional 1/10 GbE, 25 GbE, or 40/100 GbE NAS/iSCSI, 8/16/32 Gb FC, or 32 Gb NVMe/FC connections. The attachment of the Lenovo ThinkSystem DM240N 2U24 SFF and DM240S 2U24 SFF Expansion Enclosures to the controller enclosure provides scalability up to 96 NVMe SSDs or up to 480 SAS SSDs.

The ThinkSystem DM7100F Unified All Flash Array offers the following key features and benefits:

  • All-flash array capabilities with end-to-end NVMe to meet the demand for higher storage performance at lower latency and provide higher IOPs and bandwidth with lower power usage and total cost of ownership than hybrid or HDD-based solutions.
  • NVMe and SAS drive-side connectivity with up to 24x 2.5-inch small form factor (SFF) drives in the 2U24 SFF expansion enclosures.
  • Scalability to up to 96 NVMe SSDs or 480 SAS SFF solid-state drives with the attachment of the ThinkSystem DM240N 2U24 SFF and DM240S 2U24 SFF expansion enclosures to satisfy growing needs for storage performance and capacity.
  • Scalable, all flash storage with dual active/active controller configurations for high availability and performance.
  • Improved performance and data protection with RAID-DP and RAID-TEC, as well as support for traditional RAID 4.
  • Flexible host connectivity to match diverse customer needs with support for unified NAS and SAN storage protocols, including 1/10 GbE, 25 GbE, and 40/100 GbE NAS and iSCSI, 8/16/32 Gb Fibre Channel, and 32 Gb NVMe over Fibre Channel (NVMe/FC) connectivity.
  • Rich set of standard storage management functions available at no extra cost, including snapshots, volume copy, quality of service, thin provisioning, compression, deduplication, encryption, disk-based backup, application- and virtual machine-aware backup, quick data recovery, clustering, synchronous replication, and asynchronous replication.
  • Optional licensed functions, including WORM (write once, read many) data protection (SnapLock) and automated tiering of data from high-performance SSDs to object storage in public or private clouds (FabricPool).
  • Scale-out clustering of up to 12 ThinkSystem DM Series storage systems for NAS connectivity or up to six DM Series storage systems for SAN connectivity.
  • Intuitive, web-based GUI for easy system setup and management.
  • Lenovo XClarity support for centralized systems management of Lenovo x86 servers, switches, and storage, which provides automated agent-less discovery, inventory, monitoring, and additional platform-specific functions across multiple systems.
  • Designed for 99.9999% availability with redundant hot-swap components, including controllers and I/O modules, power supplies, system fans (4U controller enclosures), and non-disruptive firmware upgrades.
  • Certified storage for Oracle VM
  • Certified storage for Citrix XenServer

The DM7100F controller enclosure supports attachment of up to two ThinkSystem DM240N 2U24 SFF NVMe and up to 18 DM240S 2U24 SFF SAS expansion enclosures, or up to 20 DM240S 2U24 SFF SAS expansion enclosures. The following SFF drives are supported:

  • 1.92 TB and 3.84 TB NVMe hot-swap SSDs.
  • 1.92 TB, 3.84 TB, 7.68 TB, and 15.36 TB NVMe hot-swap SSD SEDs.
  • 960 GB, 3.84 TB, 7.68 TB, and 15.36 TB 12 Gbps SAS hot-swap SSDs.

More drives and expansion enclosures are designed to be dynamically added with virtually no downtime, which helps to quickly and seamlessly respond to ever-growing capacity demands.

The ThinkSystem DM7100F Unified All Flash Array offers high levels of system and data availability with the following technologies:

  • Dual-active controllers (high availability pair) with automatic load balancing and failover
  • Mirrored, battery-backed controller NVRAM* 
  • Automatic drive failure detection and rebuild
  • Redundant, hot-swappable and customer replaceable hardware components, including SFP+/QSFP+ transceivers, controller and I/O modules, power supplies, system fans (4U controller enclosure), and drives
  • Automated failover for the data path between the host and the drives with multipathing
  • Non-disruptive controller and drive firmware upgrades
  • Scale-out clustering

*NVRAM is battery-backed memory used to protect inbound writes as they arrive. This fact allows write operations to be safely acknowledged without having to wait for a disk operation to complete, greatly reducing write latency.

Components and connectors

The following figure shows the front of the ThinkSystem DM7100F 4U controller enclosure without a front bezel.

ThinkSystem DM7100F controller enclosure front view
Figure 2. ThinkSystem DM7100F 4U controller enclosure front view

The front of the ThinkSystem DM7100F controller enclosure includes the following components:

  • 8x Redundant hot-swap system fans.
  • Enclosure status LEDs.

The following figures show the rear of the ThinkSystem DM7100F 4U controller enclosure.

ThinkSystem DM7100F 4U controller enclosure rear view: Ports
Figure 3. ThinkSystem DM7100F 4U controller enclosure rear view: Ports

ThinkSystem DM7100F 4U controller enclosure rear view: Slots
Figure 4. ThinkSystem DM7100F 4U controller enclosure rear view: Slots

The rear of the ThinkSystem DM7100F 4U controller enclosure includes the following components:

  • Two redundant hot-swap controllers, each with the following ports:
    • Two 25 GbE SFP28 ports for direct-attach HA pair interconnect.
    • Two 40/100 GbE QSFP28 onboard ports for connections to the NVMe expansion enclosures.
    • Two 40/100 GbE QSFP28 ports on the SmartIO adapter in Slot 3 for direct-attach or switched cluster interconnect.
    • Four 12 Gb SAS x4 ports (Mini-SAS HD SFF-8644) for connections to the SAS expansion enclosures.
    • A mezzanine slot for one of the following mezzanine cards (a mezzanine card is required):
      • Four 25 GbE SFP28 host ports (NAS or iSCSI).
      • Four 4/8/16 Gb FC SFP+ host ports (FC only).
    • Four slots for the following optional adapter cards (ports per adapter card):
      • Host ports:
        • Two 1/10 GbE RJ-45 host ports (NAS or iSCSI).
        • Four 10 GbE SFP+  host ports (NAS or iSCSI).
        • Two 25 GbE SFP28 host ports (NAS or iSCSI).
        • Two 40/100 GbE QSFP28 host ports (NAS or iSCSI).
        • Four 8/16/32 Gb FC SFP+ host ports (FC or 32Gb NVMe/FC).
      • Expansion ports:
        • Two 100 GbE QSFP28 expansion ports (NVMe/RoCE).
        • Four 12 Gb SAS x4 expansion ports (Mini-SAS HD SFF-8644).
      • MetroCluster ports:
        • Two 4/8/16 Gb FC SFP+ MetroCluster FC ports (planned for the future).
        • Two 40/100 GbE iWARP QSFP28 MetroCluster IP ports.
    • One RJ-45 10/100/1000 Mb Ethernet port for out-of-band management.
    • Two serial console ports (RJ-45 and Micro-USB) for another means to configure the system.
    • One USB Type A port (read-only) for software updates.
  • Four redundant hot-swap 1600 W (100 - 240 V) AC power supplies (IEC 320-C14 power connector) with integrated cooling fans.
  • Controller status LEDs.

The following figure shows the front of the ThinkSystem DM240N 2U SFF NVMe expansion enclosure.

ThinkSystem DM240N 2U SFF NVMe expansion enclosure front view
Figure 5. ThinkSystem DM240N 2U SFF NVMe expansion enclosure front view

The front of the ThinkSystem DM240N 2U SFF NVMe expansion enclosure includes the following components:

  • 24 SFF hot-swap drive bays.
  • Enclosure status LEDs.
  • Enclosure ID LED.

The following figure shows the rear of the ThinkSystem DM240N 2U SFF NVMe expansion enclosure.

ThinkSystem DM240N 2U SFF NVMe expansion enclosure rear view
Figure 6. ThinkSystem DM240N 2U SFF NVMe expansion enclosure rear view

The rear of the ThinkSystem DM240N 2U SFF NVMe expansion enclosure includes the following components:

  • Two redundant hot-swap NVMe I/O Modules; each NVMe I/O Module provides two 100 GbE QSFP28 expansion ports for connections to the controller enclosures.
  • Two redundant hot-swap 1600 W (100 - 240 V) AC power supplies (IEC 320-C14 power connector) with integrated cooling fans.
  • NVMe I/O Module status LEDs.

The following figure shows the front of the ThinkSystem DM240S 2U SFF SAS expansion enclosure.

ThinkSystem DM240S 2U SFF SAS expansion enclosure front view
Figure 7. ThinkSystem DM240S 2U SFF SAS expansion enclosure front view

The front of the ThinkSystem DM240S 2U SFF SAS expansion enclosure includes the following components:

  • 24 SFF hot-swap drive bays.
  • Enclosure status LEDs.
  • Enclosure ID LED.

The following figure shows the rear of the ThinkSystem DM240S 2U SFF SAS expansion enclosure.

ThinkSystem DM240S 2U SFF SAS expansion enclosure rear view
Figure 8. ThinkSystem DM240S 2U SFF SAS expansion enclosure rear view

The rear of the ThinkSystem DM240S 2U SFF SAS expansion enclosure includes the following components:

  • Two redundant hot-swap I/O Modules; each I/O Module provides four 12 Gb SAS x4 expansion ports (Mini-SAS HD SFF-8644) for connections to the controller enclosures and for connecting the expansion enclosures between each other.
  • Two redundant hot-swap 913 W (100 - 240 V) AC power supplies (IEC 320-C14 power connector) with integrated cooling fans.
  • I/O Module status LEDs.
     

System specifications

The following table lists the ThinkSystem DM7100F Unified All Flash Array storage system specifications.

Note: The supported hardware options, software features, and interoperability listed in this product guide are based on the ONTAP software version 9.7. For details about specific software releases that introduced support for certain hardware options and software features, refer to the Change History for the particular software release for the ThinkSystem DM7100F Unified All Flash Array that can be found at:
http://datacentersupport.lenovo.com

Table 1. ThinkSystem DM7100F system specifications
Attribute Specification
Form factor
  • DM7100F controller enclosure (machine type 7D25): 4U rack mount.
  • DM240N 2U24 SFF expansion enclosure (machine type 7Y62): 2U rack mount.
  • DM240S 2U24 SFF expansion enclosure (machine types 7Y58, 7D7Y): 2U rack mount.
Controller configuration Dual active-active controller configuration (HA pair). Up to 6 HA pairs can be combined into a single SAN cluster, or up to 12 HA pairs can be combined into a single NAS cluster. 
HA pair interconnect ports 4x 25 GbE SFP28 onboard ports (DAC cables) (2 ports per controller).
Cluster interconnect ports 4x 100 GbE QSFP28 ports (DAC cable or SW fiber optic cable, MPO) (2 ports per controller on the pre-installed SmartIO adapter cards).
MetroCluster connectivity
  • MetroCluster IP: 4x 40/100 GbE QSFP28 ports (SW fiber optic cable, MPO) (2 ports per controller on the optional 100 GbE iWARP adapter cards). (requires ONTAP 9.8 or later)
  • MetroCluster FC: 4x 4/8/16 Gb FC SFP+ ports (SW fiber optic cable, LC) (2 ports per controller on the optional 16 Gb FC-VI adapter cards).
RAID levels RAID-4, RAID-DP, RAID-TEC.
Note: RAID-4 can be configured only through the CLI.
Controller memory 256 GB RAM per system (128 GB per controller). 32 GB battery-backed NVRAM per system (16 GB per controller) mirrored between the controllers.
Drive bays Up to 480 SFF hot-swap drive bays:
  • Up to 96 NVMe drives with up to 4x DM240N expansion enclosures.
    • More than 2x DM240N requires 2 dedicated 100GbE SN2100 switches.
  • Up to 480 SAS SSDs with up to 20x DM240S expansion enclosures.
    • Every DM240N reduces the maximum allowed DM240S by 1 and allowed SAS SSDs by 24.
Drive technology NVMe SSDs, SAS SSDs.
Drive expansion connectivity
  • 2x 100 GbE QSFP28 onboard expansion ports and 2x 100 GbE QSFP28 additional expansion ports with one 100 GbE adapter card on each of two controllers in the controller enclosure for the attachment of the NVMe expansion enclosures.
  • 2x 100 GbE QSFP28 expansion ports on each of two NVMe I/O modules in the NVMe expansion enclosure for the attachment to the controller enclosure.
  • 4x 12 Gb SAS x4 (Mini-SAS HD SFF-8644) base expansion ports and 4x or 8x 12 Gb SAS x4 (Mini-SAS HD SFF-8644) additional expansion ports with one or two SAS adapter cards on each of two controllers in the controller enclosure for the attachment of the SAS expansion enclosures.
  • 4x 12 Gb SAS x4 (Mini-SAS HD SFF-8644) expansion ports on each of two SAS I/O modules in the SAS expansion enclosure for the attachment to the controller enclosure and daisy chaining of the expansion enclosures.
Drives
  • 1.92 TB and 3.84 TB NVMe SSDs.
  • 1.92 TB, 3.84 TB, 7.68 TB, and 15.36 TB NVMe SSD SEDs.
  • 960 GB, 3.84 TB, 7.68 TB, and 15.36 TB SAS SSDs.
Storage capacity Up to 7.37 PB (480x 15.36 TB SSDs).
Storage protocols
  • NAS (File access): NFS and CIFS/SMB.
  • SAN (Block access): iSCSI, FC, NVMe/FC.
Host connectivity Base ports on the mezzanine cards (per controller enclosure):
  • 8x 25 GbE SFP28 (DAC cable or SW fiber optic cable, LC) (4 ports per controller); or
  • 8x 4/8/16 Gb FC SFP+ (SW fiber optic cable, LC) (4 ports per controller).
Optional additional ports on up to four pairs of the adapter cards (up to four adapter cards per controller) with the following ports per adapter card:
  • 2x 1/10 GbE RJ-45 (UTP Category 6/6a cables).
  • 4x 10 GbE SFP+ (DAC cables).
  • 2x 25 GbE SFP28 (DAC cables or SW fiber optic cables, LC).
  • 2x 40/100 GbE QSFP28 (DAC cables or SW fiber optic cables, MPO).
  • 4x 8/16/32 Gb FC SFP+ host ports (SW fiber optic cables, LC).
Note: ONTAP does not support host direct attach for FC protocol.
Host operating systems Microsoft Windows Server 2012 R2, 2016, and 2019; Red Hat Enterprise Linux (RHEL) 6, 7, and 8; SUSE Linux Enterprise Server (SLES) 11, 12, and 15; VMware vSphere 6.0, 6.5, 6.7, and 7.0.
Note: NVMe/FC is supported with RHEL 8 and SLES 15 only (see Operating systems for specific version details).
Performance* Up to 650 000 random read IOPS (8 KB blocks).
Configuration maximums**
  • Maximum raw storage capacity: 7.37 PB
  • Maximum aggregate size: 800 TB
  • Maximum number of FlexVol volumes per HA pair: 5000
  • Maximum volume size: 100 TB (The maximum size will be increased up to 300TB in ONTAP 9.12.1P2 and later.)
  • Maximum number of LUNs per controller: 12,288
  • Maximum number of LUNs per FlexVol volume: 512
  • Maximum LUN size: 16 TB (The maximum size will be increased up to 128TB in ONTAP 9.12.1P2 and later.)
  • Maximum number of drives in a RAID group (data + parity drives):
    • RAID 4: 14 (13 + 1 SAS SSDs or NVMe SSDs)
    • RAID-DP: 28 (26 + 2 SAS SSDs or NVMe SSDs)
    • RAID-TEC: 29 (26 + 3 SAS SSDs or NVMe SSDs)
  • Maximum number of initiators per HA pair: 8192
  • Maximum number of LUNs per HA pair: 24,576
  • Maximum number of snapshots per FlexVol volume: 1023
Cooling Redundant cooling:
  • DM7100F 4U: Eight hot-swap system fans.
  • DM240N 2U24 SFF: Fans that are built into I/O modules and power supplies.
  • DM240S 2U24 SFF: Fans that are built into power supplies.
Power supply Four 1600 W (100 - 240 V) (DM7100F 4U controller enclosure), or two 1600 W (100 - 240 V) (DM240N 2U24 SFF expansion enclosure), or two 913 W (100 - 240 V) (DM240S 2U24 SFF expansion enclosure) redundant hot-swap Platinum AC power supplies.
Hot-swap parts Controllers, I/O modules, drives, system fans (DM7100 4U only), power supplies, and SFP+/SFP28/QSFP+/QSFP28 transceivers and DAC cables.
Management ports
  • 1x 1 GbE port (UTP, RJ-45) per controller for out-of-band management.
  • 2x Serial console ports (RJ-45 and Micro-USB) for system configuration.
  • 1x USB Type A port (read-only) for software updates.
Management interfaces ThinkSystem Storage Manager web-based GUI; SSH CLI; Serial console CLI; SNMP, email, and syslog alerts; optional Lenovo XClarity.
Security features Secure Socket Layer (SSL), Secure Shell (SSH), user level security, role-based access control (RBAC), LDAP authentication.
Warranty and support Three- or five-year customer-replaceable unit and onsite limited warranty with selectable service levels: 9x5 coverage with next business day (NBD) parts delivered (base warranty), 9x5 coverage with NBD onsite response (Foundation Service), 24x7 coverage with 4-hour onsite response (Essential Service), or 24x7 coverage with 2-hour onsite response or 6-hour committed repair (select areas) (Advanced Service). Premier Support is also available. Software support is included in the base warranty or Foundation, Essential, or Advanced Service for the duration of the warranty period.
Dimensions 4U controller enclosure:
  • Height: 175 mm (6.9 in.)
  • Width: 447 mm (17.6 in.)
  • Depth: 828 mm (32.6 in.)
2U24 SFF NVMe expansion enclosure:
  • Height: 87 mm (3.4 in.)
  • Width: 447 mm (17.6 in.)
  • Depth: 543 mm (21.4 in.)
2U24 SFF SAS expansion enclosure:
  • Height: 85 mm (3.4 in.)
  • Width: 449 mm (17.7 in.)
  • Depth: 484 mm (19.1 in.)
Weight
  • Controller enclosure (fully configured): 49.2 kg (108.5 lb)
  • 2U24 SFF NVMe expansion enclosure (fully configured): 30.2 kg (66.7 lb)
  • 2U24 SFF SAS expansion enclosure (fully configured): 24.4 kg (53.8 lb)

* Estimated theoretical performance based on the capacity planning for specific configurations and workloads.
** For a detailed list of configuration limits and restrictions for a specific version of the software, refer to the Lenovo Data Center Support website:
http://datacentersupport.lenovo.com

Controller enclosures

Factory-integrated models of the ThinkSystem DM7100F Unified All Flash Array are configured by using the Lenovo Data Center Solution Configurator (DCSC):
http://dcsc.lenovo.com

The following table lists the CTO base models for the ThinkSystem DM7100F Unified All Flash Array.

Table 2. ThinkSystem DM7100F CTO base models
Description Machine Type/Model Feature code
Lenovo ThinkSystem DM7100F 7D25CTO1WW B94E

Configuration note: Two DM7100 controllers (feature code B94T) are pre-selected in the configurator.

The models of the ThinkSystem DM7100F ship with the following items:

  • One chassis with the following components:
    • Two controllers
    • Four power supplies
  • Rack Mount Kit
  • 2 m USB Cable (USB Type A to Micro-USB)
  • Electronic Publications Flyer
  • Four customer-configured power cables

Controllers

The ThinkSystem DM7100F controller enclosure ships with two DM7100 controllers. A controller provides interfaces for host connectivity, management, and internal drives, and it runs ONTAP storage management software. Each ThinkSystem DM7100 controller enclosure provides 256 GB RAM and 32 GB battery-backed NVRAM (128 GB RAM and 32 GB NVRAM per controller).

The ThinkSystem DM7100F controller enclosures ship with four HA interconnect 25 GbE SFP28 ports (two ports per controller) to cable a directly-connected dual-controller HA pair, and four cluster interconnect 100 GbE QSFP28 ports (two ports on the 100 GbE SmartIO adapter card [feature code BAZ1] installed in the Slot 3 on each of the DM7100 controllers) to cable a directly connected (one HA pair) or switched (multiple HA pairs) cluster. Up to six HA pairs can be combined into a single SAN cluster or up to 12 HA pairs can be combined into a single NAS cluster.

The ThinkSystem DM7100F controller enclosure provides four QSFP28 ports for 100 GbE NVMe expansion connectivity, and it also has two mezzanine slots (one slot per controller) for mezzanine cards and eight available expansion slots (four slots per controller) for adapter cards.

The ThinkSystem DM7100F controller enclosure also provides eight integrated 12 Gb SAS x4 expansion ports (Mini-SAS HD SFF-8644 connectors) (four ports per controller) for the attachment of the DM240S 2U24 SFF SAS expansion enclosures.

The ThinkSystem DM7100F controller enclosure provides a choice of the following interfaces on the mezzanine cards for base host connectivity (ports per mezzanine card): 

  • 4x 25 GbE SFP28 ports for NAS or iSCSI connectivity (require optical transceivers or DAC cables that should be purchased for the mezzanine card).
  • 4x 4/8/16 Gb FC SFP+ ports for FC connectivity (require SFP+ SW optical transceivers that should be purchased for the mezzanine card).

The following interfaces can be added to the ThinkSystem DM7100F controller enclosures with optional adapter cards (ports per adapter card):

  • Host interfaces
    • 2x 1/10 GbE RJ-45 ports for NAS or iSCSI connectivity (require RJ-45 UTP Category 6 cables that should be purchased for the adapter card).
    • 4x 10 GbE SFP+ ports for NAS or iSCSI connectivity (require DAC cables that should be purchased for the adapter card).
    • 2x 25 GbE SFP28 ports for NAS or iSCSI connectivity (require optical transceivers or DAC cables that should be purchased for the adapter card).
    • 2x 40/100 GbE QSFP28 ports for NAS or iSCSI connectivity (require optical transceivers or DAC cables that should be purchased for the adapter card).
    • 4x 8/16/32 Gb FC SFP+ ports for FC connectivity, or NVMe/FC with 32 Gb ports (SW SFP+ transceivers with LC connectors included).
  • Expansion interfaces:
    • 2x 100 GbE RoCE QSFP28 ports for NVMe/RoCE expansion connectivity.
    • 4x 12 Gb SAS x4 ports (Mini-SAS HD SFF-8644) for SAS expansion connectivity.
  • MetroCluster interfaces:
    • 2x 40/100 GbE iWARP QSFP28 ports for MetroCluster IP connectivity (require optical transceivers that should be purchased for the adapter card).
    • 2x 4/8/16 Gb FC SFP+ ports for MetroCluster FC connectivity (require SFP+ SW optical transceivers that should be purchased for the adapter card) (planned for the future).

Configuration notes:

  • A pair of the mezzanine cards is required for selection.
  • The optional adapter cards should be installed in pairs: Up to four pairs of the adapter cards are supported per controller enclosure (up to four adapter cards per controller), including a combination of the adapter card pairs.
  • Both controllers must have matching configurations of the mezzanine ports (type and physical connections) and adapter cards (type, quantity, slot location, and physical connections).
  • The optional adapter cards should be installed in the controller's expansion slots in the following order: Slot 2, Slot 4, Slot 1, Slot 5.
    Note: In the configurations with two DM240N expansion enclosures, a pair of additional 100 GbE RoCE adapter cards is required for dual HA direct connectivity to the expansion enclosures, and these cards must be installed in the Slot 5 of the DM7100 controllers.

The following table lists the controller for the ThinkSystem DM7100F Unified All Flash Array and supported connectivity options.

Table 3. DM7100F controller and connectivity options
Description Part number Feature code Maximum quantity per controller enclosure
Controllers
Lenovo ThinkSystem DM7100 NVMe Controller None* B94T 2
Mezzanine cards: Base host interfaces
Lenovo ThinkSystem DM Series 25Gb 4 Port Ethernet Mezz Card 4XC7A60826 B94J 2
Lenovo ThinkSystem DM Series 16Gb 4 Port Fibre Channel Mezz Card 4XC7A60827 B94K 2
Adapter cards: Additional host interfaces
Lenovo ThinkSystem DM Series 10Gb BaseT 2 port Ethernet Card 4XC7A60794 B94F 8
Lenovo ThinkSystem DM Series 10Gb 4 port Ethernet Card 4XC7A38329 B730 8
Lenovo ThinkSystem DM Series 25Gb 2 port Ethernet Card † 4XC7A38328 B72Z 6
Lenovo ThinkSystem DM Series 100Gb 2 port Ethernet Card 4XC7A38327 B72Y 6
Lenovo ThinkSystem DM Series 32Gb 4 port Fibre Channel Card 4XC7A38326 B72X 6
Adapter cards: Additional expansion interfaces
Lenovo ThinkSystem DM Series 100Gb 2 port Ethernet Card 4XC7A38327 B72Y 2
Lenovo ThinkSystem DM Series 12Gb SAS 4 Port Card 4Y37A60797 B94X 6
Adapter cards: MetroCluster interfaces
Lenovo ThinkSystem DM Series 100Gb iWARP 2 Port Ethernet Card (requires ONTAP 9.8 or later) 4XC7A60795 B94G 2
Lenovo ThinkSystem DM Series 16Gb FC-VI 2 Port SFP+ Card 4XC7A60796 B94H 2
SFP+ transceivers for 10Gb 4 port Ethernet Card (4XC7A38329)
Intel 10G Ethernet SFP+ SR Optics Module 4TC7A69986 B4SY 32
SFP+ transceivers for 16 Gb FC-VI MetroCluster adapter cards
16Gb Fibre Channel SFP+ Module 1 pack 4TC7A69990 BF5V 12
SFP+ transceivers for 16 Gb FC mezzanine cards
16Gb Fibre Channel SFP+ Module 1 pack 4XF7A14920 B4KA 12
SFP+ and SFP28 transceivers for 25 GbE mezzanine cards and 25 GbE adapter cards †
10Gb SW Optical iSCSI SFP+ Module 1 pack 4XF7A14919 B4K9 24
25Gb Ethernet Optical SFP28 Shortwave Module 1 pack 4XF7A39597 B732 24
Lenovo Dual Rate 10G/25G SR SFP28 Transceiver 7G17A03537 AV1B 24
25Gb SR SFP28 ethernet transceivers
Lenovo 25G SR SFP28 Amphenol Ethernet Transceiver 4TC7A94751 C4K4 24
QSFP+/QSFP28 transceivers for 100 GbE adapter cards and SmartIO cards
100Gb Ethernet Optical QSFP28 Shortwave Module 1 Pack 4XF7A39598 B733 20
Lenovo 100Gb SR4 QSFP28 Ethernet Transceiver 4M27A67042 BFH1 20
OM4 cables for 100 GbE QSFP28 transceivers
Lenovo 5m MPO-MPO OM4 MMF Cable 7Z57A03567 AV25 20
Lenovo 7m MPO-MPO OM4 MMF Cable 7Z57A03568 AV26 20
Lenovo 10m MPO-MPO OM4 MMF Cable 7Z57A03569 AV27 20
Lenovo 15m MPO-MPO OM4 MMF Cable 7Z57A03570 AV28 20
Lenovo 20m MPO-MPO OM4 MMF Cable 7Z57A03571 AV29 20
Lenovo 30m MPO-MPO OM4 MMF Cable 7Z57A03572 AV2A 20
OM4 cables for 16/32 Gb FC and 25 GbE SFP28 optical transceivers
Lenovo 0.5m LC-LC OM4 MMF Cable 4Z57A10845 B2P9 32
Lenovo 1m LC-LC OM4 MMF Cable 4Z57A10846 B2PA 32
Lenovo 3m LC-LC OM4 MMF Cable 4Z57A10847 B2PB 32
Lenovo 5m LC-LC OM4 MMF Cable 4Z57A10848 B2PC 32
Lenovo 10m LC-LC OM4 MMF Cable 4Z57A10849 B2PD 32
Lenovo 15m LC-LC OM4 MMF Cable 4Z57A10850 B2PE 32
Lenovo 25m LC-LC OM4 MMF Cable 4Z57A10851 B2PF 32
Lenovo 30m LC-LC OM4 MMF Cable 4Z57A10852 B2PG 32
OM3 cables for 16/32 Gb FC and 25 GbE SFP28 optical transceivers
Lenovo 0.5m LC-LC OM3 MMF Cable 00MN499 ASR5 32
Lenovo 1m LC-LC OM3 MMF Cable 00MN502 ASR6 32
Lenovo 3m LC-LC OM3 MMF Cable 00MN505 ASR7 32
Lenovo 5m LC-LC OM3 MMF Cable 00MN508 ASR8 32
Lenovo 10m LC-LC OM3 MMF Cable 00MN511 ASR9 32
Lenovo 15m LC-LC OM3 MMF Cable 00MN514 ASRA 32
Lenovo 25m LC-LC OM3 MMF Cable 00MN517 ASRB 32
Lenovo 30m LC-LC OM3 MMF Cable 00MN520 ASRC 32
SFP+ DAC cables for 10 GbE SFP+ adapter cards
0.5m Passive DAC SFP+ Cable 00D6288 A3RG 32
1m Passive DAC SFP+ Cable 90Y9427 A1PH 32
1.5m Passive DAC SFP+ Cable 00AY764 A51N 32
2m Passive DAC SFP+ Cable 00AY765 A51P 32
3m Passive DAC SFP+ Cable 90Y9430 A1PJ 32
5m Passive DAC SFP+ Cable 90Y9433 A1PK 32
SFP28 DAC cables for 25 GbE onboard ports, mezzanine cards, and adapter cards
Lenovo 1m Passive 25G SFP28 DAC Cable 7Z57A03557 AV1W 26
Lenovo 3m Passive 25G SFP28 DAC Cable 7Z57A03558 AV1X 26
Lenovo 5m Passive 25G SFP28 DAC Cable 7Z57A03559 AV1Y 26
QSFP+ DAC cables for 100 GbE adapter cards and SmartIO cards (operating at 40 Gbps)
Lenovo 1m Passive QSFP+ DAC Cable 49Y7890 A1DP 20
Lenovo 3m Passive QSFP+ DAC Cable 49Y7891 A1DQ 20
Lenovo 5m Passive QSFP+ DAC Cable 00D5810 A2X8 20
QSFP28 DAC cables for 100 GbE adapter cards and SmartIO cards (operating at 100 Gbps)
Lenovo 1m Passive 100G QSFP28 DAC Cable 7Z57A03561 AV1Z 20
Lenovo 3m Passive 100G QSFP28 DAC Cable 7Z57A03562 AV20 20
Lenovo 5m Passive 100G QSFP28 DAC Cable 7Z57A03563 AV21 20
UTP Category 6 cables for 1/10 GbE RJ-45 adapter cards and 1 GbE RJ-45 management ports
0.75m Green Cat6 Cable 00WE123 AVFW 18
1.0m Green Cat6 Cable 00WE127 AVFX 18
1.25m Green Cat6 Cable 00WE131 AVFY 18
1.5m Green Cat6 Cable 00WE135 AVFZ 18
3m Green Cat6 Cable 00WE139 AVG0 18
10m Cat6 Blue Cable 90Y3721 A1MU 18
10m Cat6 Green Cable 90Y3718 A1MT 18
10m Cat6 Yellow Cable 90Y3715 A1MS 18
25m Cat6 Blue Cable 90Y3730 A1MX 18
25m Cat6 Green Cable 90Y3727 A1MW 18
25m Cat6 Yellow Cable 90Y3724 A1MV 18

* Factory-installed only.
† For 25G leverage: 4M27A67041, BFH2 Lenovo 25Gb SR SFP28 Ethernet Transceiver

Expansion enclosures

The ThinkSystem DM7100F controller enclosure supports attachment of up to two ThinkSystem DM240N 2U24 SFF NVMe and up to eight DM240S 2U24 SFF SAS expansion enclosures. The expansion enclosures can be added to the system non-disruptively.

Note: The addition of the second DM240N NVMe expansion enclosure to the storage arrays that were previously configured with one DM240N NVMe expansion enclosure requires planned system downtime.

The following table lists the CTO base models for the expansion enclosures.

Table 4. CTO base models for the ThinkSystem DM Series expansion enclosures
Description Machine Type/Model Feature code
DM240S 2U24 SFF Expansion Enclosure (1-year warranty) 7Y58CTO1WW BEY7
DM240S 2U24 SFF Expansion Enclosure (3-year warranty) 7D7YCTO1WW BEY7
DM240N NVMe 2U24 SFF Expansion Enclosure (3-year warranty) 7Y62CTO1WW B6W6

Configuration notes:

  • Two NVMe I/O expansion modules (feature code B73A) are pre-selected in the configurator for the DM240N 2U24 SFF expansion enclosures.
  • Two SAS I/O expansion modules (feature code B39J) are pre-selected in the configurator for the DM240S 2U24 SFF expansion enclosures.

The models of the ThinkSystem DM240N and DM240S 2U24 SFF expansion enclosures ship with the following items:

  • One chassis with the following components:
    • Two I/O modules (NVMe or SAS)
    • Two power supplies
  • Rack Mount Kit
  • Electronic Publications Flyer
  • Two customer-configured power cables

The following expansion connectivity topologies are supported:

NVMe expansion topology

Each ThinkSystem DM240N expansion enclosure ships with two NVMe I/O expansion modules. Each NVMe I/O expansion module provides two external 100 GbE QSFP28 ports (labelled Ports A and B) that are used for direct-attach connections to the ThinkSystem DM7100F controller enclosures.

The ThinkSystem DM7100F controller enclosure supports direct attachment of up to two DM240N NVMe expansion enclosures for a total of up to 48 NVMe drives. For one NVMe expansion enclosure, the integrated 100 GbE QSFP28 ports on the DM7100 controller can be used. For two NVMe expansion enclosures, an additional 2-port 100 GbE QSFP28 adapter card is required for the DM7100 controller.

The example expansion connectivity topologies for one and two enclosures with dual-path HA (high availability) are shown in the following figures.

DM7100F NVMe expansion connectivity topology: One enclosure
Figure 9. DM7100F NVMe expansion connectivity topology: One enclosure

DM7100F NVMe expansion connectivity topology: Two enclosures
Figure 10. DM7100F NVMe expansion connectivity topology: Two enclosures

NVMe expansion cabling rules:

  • On the Controller A, the integrated 100 GbE Port C is connected to the Port A on the NVMe I/O Module A in the first expansion enclosure, and the integrated 100 GbE Port D is connected to the Port B in the NVMe I/O Module B in the same (in case of only one expansion enclosure) or second expansion enclosure.
  • On the Controller B, the integrated 100 GbE Port C is connected to the Port A on the NVMe I/O Module B in the first expansion enclosure, and the integrated 100 GbE Port D is connected to the Port B in the NVMe I/O Module A in the same (in case of only one expansion enclosure) or second expansion enclosure.
  • On the Controller A, the Port 1 on the 100 GbE adapter card is connected to the Port A on the NVMe I/O Module A in the second expansion enclosure, and the Port 2 on the 100 GbE adapter card is connected to the Port B in the NVMe I/O Module B in the first expansion enclosure.
  • On the Controller B, the Port 1 on the 100 GbE adapter card is connected to the Port A on the NVMe I/O Module B in the second expansion enclosure, and the Port 2 on the 100 GbE adapter card is connected to the Port B in the NVMe I/O Module A in the first expansion enclosure.

The following table lists ordering information for the NVMe expansion enclosure connectivity options.

Table 5. NVMe expansion enclosure connectivity options
Description Part number Feature code Maximum quantity per one expansion enclosure
Lenovo 1m Passive 100G QSFP28 DAC Cable 7Z57A03561 AV1Z 4
Lenovo 3m Passive 100G QSFP28 DAC Cable 7Z57A03562 AV20 4
Lenovo 5m Passive 100G QSFP28 DAC Cable 7Z57A03563 AV21 4

Configuration note: Four 100G QSFP28 DAC cables are needed per expansion enclosure for directly connecting the expansion enclosure to the controller enclosure.

SAS expansion topology

Each ThinkSystem DM240S expansion enclosure ships with two SAS I/O expansion modules. Each I/O expansion module provides four external 12 Gb SAS x4 ports (Mini-SAS HD SFF-8644 connectors labelled Port 1-4) that are used for connections to the ThinkSystem DM7100F controller enclosure and for daisy chaining the expansion enclosures between each other.

The ThinkSystem DM7100F controller enclosure supports up to six SAS expansion enclosure stacks with up to four enclosures in each stack for a total of up to 480 SAS SSDs. For one or two stacks, the integrated SAS expansion ports on the DM7100 controller can be used. For three or four stacks, an additional 4-port SAS adapter card is required for the DM7100 controller. For five or six stacks, two additional 4-port SAS adapter cards are required for the DM7100 controller.

The example expansion connectivity topology for one or two enclosure stacks with dual-path HA (high availability) are shown in the following figures.

DM7100F SAS expansion connectivity topology: One stack
Figure 11. DM7100F SAS expansion connectivity topology: One stack

DM7100F SAS expansion connectivity topology: Two stacks
Figure 12. DM7100F SAS expansion connectivity topology: Two stacks

SAS expansion cabling rules:

  • Ports A and C (integrated and on the SAS adapter cards) on the Controller 1 are primary paths to separate stacks; each port is connected to the Port 1 on the I/O Module A in the first expansion enclosure in the stack.
  • Ports A and C (integrated and on the SAS adapter cards) on the Controller 2 are primary paths to separate stacks; each port is connected to the Port 1 on the I/O Module B in the first expansion enclosure in the stack.
  • Ports A at the same location (either integrated or on the SAS adapter cards) on both controllers are connected to the same stack; Ports C at the same location (either integrated or on the SAS adapter cards) on both controllers are connected to the same stack.
  • Ports B and D (integrated and on the SAS adapter cards) on the Controller 1 are secondary paths to separate stacks; each port is connected to the Port 3 on the I/O Module B in the last expansion enclosure in the stack.
  • Ports B and D (integrated and on the SAS adapter cards) on the Controller 2 are secondary paths to separate stacks; each port is connected to the Port 3 on the I/O Module A in the last expansion enclosure in the stack.
  • Ports B at the same location (either integrated or on the SAS adapter cards) on both controllers are connected to the same stack; Ports D at the same location (either integrated or on the SAS adapter cards) on both controllers are connected to the same stack.
  • Port 3 on the I/O Module A in the first expansion enclosure in a stack is connected to Port 1 on the I/O Module A in the adjacent expansion enclosure in the same stack, and so on (until the last expansion enclosure in the stack is cabled).
  • Port 3 on the I/O Module B in the first expansion enclosure in a stack is connected to Port 1 on the I/O Module B in the adjacent expansion enclosure in the same stack, and so on (until the last expansion enclosure in the stack is cabled).

The following table lists ordering information for the SAS expansion enclosure connectivity options.

Table 6. SAS expansion enclosure connectivity options
Description Part number Feature code Maximum quantity per one expansion enclosure
External MiniSAS HD 8644/MiniSAS HD 8644 0.5M Cable 00YL847 AU16 4
External MiniSAS HD 8644/MiniSAS HD 8644 1M Cable 00YL848 AU17 4
External MiniSAS HD 8644/MiniSAS HD 8644 2M Cable 00YL849 AU18 4
External MiniSAS HD 8644/MiniSAS HD 8644 3M Cable 00YL850 AU19 4

Configuration notes:

  • The following quantities of SAS cables are needed per stack of the SAS expansion enclosures:
    • Two SAS cables per expansion enclosure in the stack for connecting the first expansion enclosure in the stack to the controller enclosure and for connections to the adjacent expansion enclosures.
    • Two additional SAS cables for connecting the last expansion enclosure in the stack to the controller enclosure.
  • The length of the SAS cables that connect a 2U24 SAS enclosure to an adjacent 4U controller enclosure should be at least 1 meter.

Drives

With the DM7100F, the drives are installed in the expansion enclosures. The ThinkSystem DM240N 2U24 SFF expansion enclosures support up to 24 SFF NVMe hot-swap SSDs, and the DM240S 2U24 SFF expansion enclosures support up to 24 SFF SAS/SATA hot-swap SSDs.

The following table lists supported drive packs for the controller and expansion enclosures.

Configuration notes:

  • When ordering the systems, select the drives that match the ONTAP offering and bundle you are installing on the DM controller. Drive feature codes are specific to Unified or SAN Only offerings, and to Base, Fundamentals and Premium bundles. See the Software section for details.
  • Drives are sold in packs. Supported quantities are as follows:
    • The DM240N 2U24 SFF expansion enclosure supports 12, 18 or 24 NVMe drives (4 packs of 6 drives)
    • The DM240S 2U24 SFF expansion enclosure supports 12, 18 or 24 SAS/SATA drives (4 packs of 6 drives)
    • A minimum of 2 drive packs is required.
  • For factory-installed drive packs, all drives in the enclosure must be of the same type and capacity.

Field upgrades: Drive packs for field upgrades can be ordered via the CTO base 7D4FCTO1WW, ThinkSystem DM Drive Pack Upgrades for DM7100. These are for use in existing expansion enclosures that have not been fully populated with the factory-installed drive packs

Table 7. DM240N 2U24 SFF drive options
Description Part number Feature code Maximum quantity
per 2U24
enclosure
 2.5-inch NVMe hot-swap SSDs (non-SED)
Lenovo ThinkSystem 11.5TB (6x 1.92TB NVMe Non-SED) Drive Pack None* BC81 4
Lenovo ThinkSystem 23TB (6x 3.84TB NVMe Non-SED) Drive Pack None* BC7W 4
2.5-inch NVMe hot-swap SSD SEDs**
Lenovo ThinkSystem 11.5TB (6x 1.92TB NVMe SED) Drive Pack None* BC7Z 4
Lenovo ThinkSystem 23TB (6x 3.84TB NVMe SED) Drive Pack None* BC7U 4
Lenovo ThinkSystem 23TB (6x 3.84TB NVMe SED FIPS) Drive Pack None* BC7V 4
Lenovo ThinkSystem 46TB (6x 7.68TB NVMe SED) Drive Pack None* BC7Y 4
Lenovo ThinkSystem 92TB (6x 15.36TB NVMe SED) Drive Pack None* BC80 4

* Drive packs for field upgrades can be ordered via the CTO base 7D4FCTO1WW (refer to the configuration note).
** Available worldwide except PRC and RUCIS markets

The following table lists supported drive options for the DM240S 2U24 SFF expansion enclosures.

Table 8. DM240S 2U24 SFF drive options: 2.5-inch SAS hot-swap SSDs
Description Part number Feature code Maximum quantity
per 2U24
enclosure
ThinkSystem 5.76TB (6x 960GB, 2.5", SSD) Drive Pack for DM7100F None* BC7L 4
ThinkSystem 23TB (6x 3.84TB, 2.5", SSD) Drive Pack for DM7100F None* BC7M 4
ThinkSystem 46TB (6x 7.68TB, 2.5", SSD) Drive Pack for DM7100F None* BC7Q 4
ThinkSystem 92TB (6x 15.36TB, 2.5", SSD) Drive Pack for DM7100F None* BC7S 4

* Drive packs for field upgrades can be ordered via the CTO base 7D4FCTO1WW (refer to the configuration note).

The following table lists supported drive options for the DM240N NVMe 2U24 SFF Expansion Enclosure.

Table 9. DM240N NVMe 2U24 SFF two drive packs
Description Part number Feature code Maximum quantity
per 2U24
enclosure
Essential Bundle
Lenovo ThinkSystem 3.84TB (2x 1.9TB NVMe SED) Drive Pack for DM7100F None C3X2* 12
Lenovo ThinkSystem 7.68TB (2x 3.84TB NVMe SED) Drive Pack for DM7100F None C3XX* 12
Lenovo ThinkSystem 15.4TB (2x 7.68TB NVMe SED) Drive Pack for DM7100F None C3XW* 12
Lenovo ThinkSystem 30.7TB (2x 15.36TB NVMe SED) Drive Pack for DM7100F None C3XV* 12
Complete Bundle
Lenovo ThinkSystem 3.84TB (2x 1.9TB NVMe SED) Drive Pack for DM7100F None C3XU 12
Lenovo ThinkSystem 7.68TB (2x 3.84TB NVMe SED) Drive Pack for DM7100F None C3XT 12
Lenovo ThinkSystem 15.4TB (2x 7.68TB NVMe SED) Drive Pack for DM7100F None C3XR 12
Lenovo ThinkSystem 30.7TB (2x 15.36TB NVMe SED) Drive Pack for DM7100F None C3XQ 12
NVMe SED FIPS Complete Bundle
Lenovo ThinkSystem 7.68TB (2x 3.84TB NVMe SED FIPS) Drive Pack for DM7100F None C3XS† 12

* China only
† Available world-wide except China

Software

In this section:

ONTAP software unifies data management across flash, disk, and cloud to simplify the Lenovo DM storage environment. It builds the foundation for a Data Fabric, making it easy to move the data where it is needed across flash, disk, and cloud resources. 

Feature bundles

Controller software for the DM7100F is available in the following bundles of features:

  • Unified Essentials (China only) (Feature BWU9)
  • Unified Complete (Feature BWU8)

The following table summarizes the features in each bundle for the DM7100F.

Table 10. Comparison of software features for the DM7100F
Feature Unified Essentials
(PRC only)

Unified Complete (WW)

Controller software feature code BWU9 BWU8
RAID-4, RAID-DP, and RAID-TEC data protection Included Included
SAN (Block access): iSCSI, FC, NVMe/FC Included Included
NAS (File access): NFS, CIFS/SMB Included Included
Thin provisioning Included Included
Compression Included Included
Deduplication Included Included
Snapshots Included Included
Encryption* No Included*†
Balanced placement Included Included
Dynamic capacity expansion Included Included
Adaptive Quality of Service Included Included
SnapRestore Included Included
FlexClone Included Included
FlexVol Included Included
FlexCache Included Included
SnapMirror asynchronous replication No Included
SyncMirror data protection Included Included
Trusted Platform Module (TPM) support No Included†
MetroCluster IP Included Included
NVMe over FC Protocol Included Included
NVMe over TCP Protocol Included Included
SnapMirror Business Continuity (SMBC) No Included
SnapMirror synchronous replication No Included
FlexGroup Included Included
SnapVault disk-based storage backup No Included
SnapCenter No Included
ONTAP S3 Included Included
ONTAP S3 SnapMirror No Included
SnapLock data protection No Included
Multitenant Key Management No Included
Anti-ransomware Protection No Included
SnapMirror Cloud No Included
FabricPool object storage tiering Optional Optional

* Requires the encryption version of ONTAP. See the ONTAP software section.
† Not available in PRC

The features are summarized as follows: 

  • RAID-4, RAID-DP, and RAID-TEC data protection: Provides the flexibility to choose the level of data protection required and helps improve performance and availability with built-in spare capacity and by distributing data across all physical drives in the aggregate, sustaining to up to one (RAID-4), two (RAID-DP), or three (RAID-TEC) concurrent drive failures. 
  • All Flash Array (AFA) capability: Meets the demand for higher speed, lower latency storage and provides higher IOPS and bandwidth with lower power usage and total cost of ownership than hybrid or HDD-based solutions.
  • Thin provisioning: Optimizes efficiency by allocating storage space based on the minimum space required by each application at any given time, so that applications consume only the space they are actually using, not the total space that has been allocated to them, which allows customers to purchase storage they need today and add more as application requirements grow. 
  • Compression: Provides transparent inline and post-process data compression to reduce the amount of storage that customers need to purchase and manage. 
  • Compaction: enhances compression to further reduce the amount of storage that customers need to purchase and manage. 
  • Deduplication: Performs general-purpose deduplication for removal of redundant data to reduce the amount of storage that customers need to purchase and manage. 
  • Snapshots: Enables creation of read-only copies of data for backup, parallel processing, testing, and development, and have the copies available almost immediately. 
  • Encryption: Provides software-based encryption for data at rest for enhanced data security with the traditional drives and embedded key management (requires the encryption-capable version of the ONTAP software). 
  • Balanced placement: Provides automated workload distribution across the cluster to help increase utilization and performance. 
  • Dynamic capacity expansion: Allows the capacity of a volume or aggregate to be expanded by adding new physical drives. 
  • Adaptive Quality of Service: Simplifies operations and maintains consistent workload performance by defining QoS policies and automatically adjusting storage resources to respond to workload changes. 
  • SnapRestore: Enables quick recovery of data by reverting a local volume or file to its previous state from a particular snapshot copy stored on the file system. 
  • FlexClone: References snapshot metadata to create writable point-in-time copies of a volume. 
  • FlexVol: Provides abstraction layer between the logical volume and its physical location in the storage array. 
  • FlexCache: Speeds up access to data and offloads traffic from heavily accessed volumes for read-intensive workloads by placing frequently used data in cache locally or remotely (closer to the point of client access) and serving the data to the clients directly from cache without accessing the data source. 
  • SnapMirror asynchronous replication: Provides storage system-based data replication between the storage systems containing source (local) and destination (remote) volumes by using asynchronous (at specified regular intervals) data transfers over IP communication links. 
  • SyncMirror data protection: Adds extra level of data protection and availability by mirroring a pair of RAID aggregates. 
  • Trusted Platform Module (TPM): For encryption enabled systems.  The encryption keys for the onboard key manager (OKM) are no longer stored in the boot device, but instead are stored in the physical TPM for systems so equipped, offering greater security and protection. Moving to the TPM is a nondisruptive process.
  • MetroCluster IP: Provides storage system-based clustering with online, real-time data mirroring between the local and remote sites by using synchronous data transfers over IP communication links to deliver continuous availability with zero RPO and near-zero RTO. All storage systems in a MetroCluster IP configuration must be of the same model. New to ONTAP 9.11: MetroCluster with Storage Virtual Machine Disaster Recovery (SVM-DR) can now use a third site for the SVM-DR
  • NVMe over FC Protocol: Enables NVMe over FC
  • NVMe over TCP Protocol: Enables NVMe over TCP
  • Data Protection Optimized (DPO): Increases the amount of concurrent SnapMirror sessions per node, as well as improving SnapMirror performance to the cluster.
  • SnapMirror Business Continuity (SMBC): Non-disruptive failover active-active cross site clusters. Based on existing SnapMirror Synchronous Replication. Offers Zero data loss, zero downtime. You do not have to failover the application. If there is a failure the application will continue to run and there will be no need to restart.
  • SnapMirror synchronous replication: Provides storage system-based data replication between the storage systems containing source (local) and destination (remote) volumes by using synchronous (as soon as the data is written to the source volume)
  • FlexGroup: Enables a single volume to span across multiple clustered storage arrays to maximize storage capacity and automate load distribution. New to ONTAP 9.11: FlexGroups can now be created as SnapLock volumes.
  • SnapVault disk-based storage backup: Enables data stored on multiple systems to be backed up to a central, secondary system quickly and efficiently as read-only snapshot copies. 
  • SnapCenter: Provides application- and virtual machine-aware backup and restoration of data by using the Snapshots technology and leverages the SnapMirror capabilities of storage systems to provide onsite or offsite backup set mirroring for disaster recovery. 
  • ONTAP S3: Expands the DM Series unified story and allows customers to manage, block, file, and object data from one interface. Customers can now natively store data in S3 buckets onboard the DM Series. 
  • ONTAP S3 SnapMirror : Enables you to protect buckets in ONTAP S3 object stores using familiar SnapMirror mirroring and backup functionality. Requires ONTAP 9.11 or later on both source and destination clusters. Requires the Unified Premium Bundle.
  • SnapMirror Cloud: A backup and recovery technology designed for ONTAP users who want to transition their data protection workflows to the cloud. SnapMirror Cloud is an extension to the family of SnapMirror replication technologies. While SnapMirror is frequently used for ONTAP-to-ONTAP backups, SnapMirror Cloud uses the same replication engine to transfer Snapshot copies for ONTAP to S3-compliant object storage backups.
  • Multitenant Key Management (MTKM): Provides the ability for individual tenants or storage virtual machines (SVMs) to maintain their own keys through KMIP for NVE. With multitenant external key management, you can centralize your organization’s key management functions by department or tenant while inherently confirming that keys are not stored near the assets. This approach decreases the possibility of compromise.
  • Anti-ransomware: Uses workload analysis in NAS (NFS and SMB) environments to proactively detect and warn about abnormal activity that might indicate a ransomware attack. When an attack is suspected, anti-ransomware also creates new Snapshot backups, in addition to existing protection from scheduled Snapshot copies. New to ONTAP 9.11: Optional multi-admin verification to approve administration functions that could result in data loss.

Add-on feature bundles:

  • Security and Compliance Bundle: Licensed per 2-node HA Pair, the Security and Compliance Bundle provides built-in protection from ransomware and while also providing the ability to meet regulatory compliance and organizational data retention requirements.
    • Includes: Anti-ransomware feature with Multitenant Key Management (MTKM) and SnapLock
  • Hybrid Cloud Bundle: Licensed per TB (3 Year & 5 Year Offerings) the Hybrid Cloud Bundle provides the ability to use S3 SnapMirror from ONTAP to the Public Cloud (AWS S3) and/or SnapMirror Cloud with participating ISV Backup providers.
    • Includes SnapMirror Cloud and FabricPool

Optional Extended features also available via Feature on Demand (FoD) (see the Extended ONTAP features section)

  • FabricPool: FabricPool is a hybrid storage solution that uses an all flash (all SSD) aggregate as the performance tier and an object store as the external capacity tier. Data in a FabricPool is stored in a tier based on whether it is frequently accessed or not. Using a FabricPool helps you reduce storage cost without compromising performance, efficiency, or protection.
  • No license is required when tiering to StorageGRID or ONTAP S3
  • SnapLock data protection: Creates Write-Once-Read-Many (WORM) non-rewritable, non-erasable data on hard disk drives to prevent files from being altered or deleted until a predetermined or default retention date.

ONTAP software versions

The following table lists the software selection options for the DM7100F. The table also indicates which markets each version is available in.

Table 11. Software selection
Feature
code
Description Availability
ONTAP 9.7  
BAYJ Lenovo ThinkSystem DM Series ONTAP 9.7 SW Base NonEncryption China only
BAYL Lenovo ThinkSystem DM Series ONTAP 9.7 Software Encryption All markets
BAYK Lenovo ThinkSystem DM Series ONTAP 9.7 Software NonEncryption All markets
ONTAP 9.8  
BF5S Lenovo ThinkSystem DM Series ONTAP 9.8 Software Base NonEncryption China only
BF5Q Lenovo ThinkSystem DM Series ONTAP 9.8 Software Encryption All markets except China
BF5R Lenovo ThinkSystem DM Series ONTAP 9.8 Software NonEncryption All markets
ONTAP 9.9  
BKF7 Lenovo ThinkSystem DM Series ONTAP 9.9 Software Base NonEncryption China only
BKFB Lenovo ThinkSystem DM Series ONTAP 9.9 Software Encryption All markets
BKFA Lenovo ThinkSystem DM Series ONTAP 9.9 Software NonEncryption All markets
ONTAP 9.10  
BNLY Lenovo ThinkSystem DM Series ONTAP 9.10 Software Base NonEncryption China only
BNM2 Lenovo ThinkSystem DM Series ONTAP 9.10 Software Encryption All markets except China
BNM1 Lenovo ThinkSystem DM Series ONTAP 9.10 Software NonEncryption All markets
ONTAP 9.11  
BRK0 Lenovo ThinkSystem DM Series ONTAP 9.11 Software Base NonEncryption China only
BRJW Lenovo ThinkSystem DM Series ONTAP 9.11 Software Encryption All markets except China
BRJX Lenovo ThinkSystem DM Series ONTAP 9.11 Software NonEncryption All markets
ONTAP 9.12  
BX90 Lenovo ThinkSystem Storage ONTAP 9.12 Software Encryption - IPAv2 All markets
BX91 Lenovo ThinkSystem Storage ONTAP 9.12 Software NonEncryption - IPAv2 All markets
BU6S Lenovo ThinkSystem DM Series ONTAP 9.12 Software Encryption All markets
BU6R Lenovo ThinkSystem DM Series ONTAP 9.12 Software NonEncryption All markets
BU6N Lenovo ThinkSystem DM Series ONTAP 9.12 Software Base NonEncryption China only
ONTAP 9.13  
BWUA Lenovo ThinkSystem Storage ONTAP 9.13 Software Encryption - IPAv2 All markets
BWUB Lenovo ThinkSystem Storage ONTAP 9.13 Software NonEncryption - IPAv2 All markets
ONTAP 9.14  
C0S6 Lenovo ThinkSystem Storage ONTAP 9.14 Software Encryption - IPAv2 All markets
C0S7 Lenovo ThinkSystem Storage ONTAP 9.14 Software NonEncryption - IPAv2 All markets
ONTAP 9.15  
C4K5 Lenovo ThinkSystem Storage ONTAP 9.15 Software Encryption - IPAv2 All markets
C4K6 Lenovo ThinkSystem Storage ONTAP 9.15 Software NonEncryption - IPAv2 All markets

Software maintenance is included in the DM7100F warranty and support (see Warranty and support for details).

Extended ONTAP features

FabricPool and SnapLock WORM data protection are optional extended features. To obtain these feature licenses, order the part numbers as listed in the following table. Upgrades are supported in specific bundles as listed in the Comparison of software features table.

Note: Extended features are only available as field upgrades and are not orderable as part of a CTO configuration.

Table 12. Optional software features
Part number Feature code Description Quantity
4P47A16547 None* DM Series SnapLock License 1 per system (contains two licenses)
4P47A37057 None* DM Series FabricPool – 1TB Increment – 3 years 1 per TB of storage capacity
4P47A37288 None* DM Series FabricPool – 1TB Increment – 5 years 1 per TB of storage capacity
4P47A82668 BPQ6 Security and Compliance Bundle 1 per system (contains two licenses)
4P47A83121 BQ8X Hybrid Cloud Bundle 3 year per TB License 1 per TB of storage capacity
4P47A83123 BQ8W Hybrid Cloud Bundle 5 year per TB License 1 per TB of storage capacity

* Field upgrade only; no factory installation.

Configuration notes:

  • The SnapLock feature is licensed on a per-controller basis; that is, two licenses are needed per system, and these two licenses are contained in a single orderable part number. These licenses also include 5-year software support entitlement.
  • The FabricPool feature is a cluster-wide, capacity-based license that is available for 3-year or 5-year subscription terms.

Upgrading to Unified Premium ONTAP

PRC only: This section only applies to customers in China who are using the Unified Base offering.

To upgrade your existing ONTAP installation to Unified Premium ONTAP, use DCSC to specify the storage you already have installed, since the upgrade license is based on your existing configuration.
https://dcsc.lenovo.com/#/configuration/cto/7D4FCTO2WW?hardwareType=storage

The software license for field upgrades is ordered via the CTO base 7D4FCTO2WW, as listed in the following table.

Table 13. Feature codes for ONTAP upgrades (MTM 7D4FCTO2WW)
Feature code Description
BNKN Unified Base to Unified Premium CFC Selection (PRC only)

Ansible playbooks for DM Series

Ansible Playbooks give customers the ability to quickly deploy and use DM Series storage systems using a standard open source deployment tool. Each playbook executes a set of tasks to achieve a configuration/provisioning goal.

Lenovo has created playbooks that can be used with DM Series storage systems to help with:

  • Provisioning
  • Configuring

To access the Ansible Playbooks for Lenovo ThinkSystem DM Series storage systems, go to the following page:
https://github.com/lenovo/ansible-dm-series-ontap

Management

The ThinkSystem DM7100F Unified All Flash Array supports the following management interfaces:

  • Lenovo ThinkSystem Storage Manager, a web-based interface via HTTPS for single-system management or centralized management of the cluster of systems, that runs on the storage system itself and requires only a supported browser (Microsoft Internet Explorer, Google Chrome, or Mozilla Firefox), so there is no need for a separate console or plug-in.
  • Command line interface (CLI) via SSH or through serial console.
  • Syslog, SNMP, and e-mail notifications.
  • Optional Lenovo XClarity for discovery, inventory, monitoring, and alerts.

Power supplies and cables

The ThinkSystem DM7100F 4U controller enclosure ships with four redundant hot-swap 1600 W (100 - 240 V) Platinum AC power supplies, each with an IEC 320-C14 connector.

The ThinkSystem DM240N 2U24 SFF expansion enclosures ship with two redundant hot-swap 1600 W (100 - 240 V) Platinum AC power supplies, each with an IEC 320-C14 connector.

The ThinkSystem DM240S 2U24 SFF expansion enclosures ship with two redundant hot-swap 913 W (100 - 240 V) Platinum AC power supplies, each with an IEC 320-C14 connector.

Each ThinkSystem DM Series enclosure requires the selection of two or four power cables, depending on the quantity of the power supplies in the enclosure.

The following table lists the rack power cable and line cord options that can be ordered for the DM7100F 4U, DM240N 2U24 SFF, and DM240S 2U24 SFF enclosures (two or four power cords per enclosure).

Table 14. Power cables for DM7100F 4U, DM240N 2U24 SFF, and DM240S 2U24 SFF enclosures
Description Part number Feature code
Rack power cables
1.0m, 13A/100-250V, C13 to IEC 320-C14 Rack Power Cable 4L67A08367 B0N5
1.2m, 16A/100-250V, 2 Short C13s to Short C20 Rack Power Cable 47C2491 A3SW
1.5m, 13A/100-250V, C13 to IEC 320-C14 Rack Power Cable 4L67A08368 B0N6
2.0m, 13A/125V-10A/250V, C13 to IEC 320-C14 Rack Power Cable 4L67A08369 6570
2.5m, 16A/100-250V, 2 Long C13s to Short C20 Rack Power Cable 47C2492 A3SX
2.8m, 13A/125V-10A/250V, C13 to IEC 320-C14 Rack Power Cable 4L67A08370 6400
2.8m, 16A/100-250V, 2 Short C13s to Long C20 Rack Power Cable 47C2493 A3SY
4.1m, 16A/100-250V, 2 Long C13s to Long C20 Rack Power Cable 47C2494 A3SZ
4.3m, 13A/125V-10A/250V, C13 to IEC 320-C14 Rack Power Cable 4L67A08371 6583
Line cords
2.8m, 10A/250V, C13 to AS/NZS 3112 Line Cord 39Y7924 6211
2.8m, 10A/250V, C13 to BS 1363/A Line Cord 39Y7923 6215
2.8m, 10A/250V, C13 to CEE7-VII Line Cord 39Y7917 6212
2.8m, 10A/250V, C13 to CEI 23-16 Line Cord 39Y7921 6217
2.8m, 10A/250V, C13 to CNS 10917-3 Line Cord 81Y2375 6317
2.8m, 10A/250V, C13 to DK2-5a Line Cord 39Y7918 6213
2.8m, 10A/250V, C13 to GB 2099.1 Line Cord 39Y7928 6210
2.8m, 10A/250V, C13 to IRAM 2073 Line Cord 39Y7930 6222
2.8m, 10A/250V, C13 to IS 6538 Line Cord 39Y7927 6269
2.8m, 10A/250V, C13 to NBR 14136 Line Cord 69Y1988 6532
2.8m, 10A/250V, C13 to NEMA 6-15P Line Cord 46M2592 A1RF
2.8m, 10A/250V, C13 to SABS 164 Line Cord 39Y7922 6214
2.8m, 10A/250V, C13 to SEV 1011-S24507 Line Cord 39Y7919 6216
2.8m, 10A/250V, C13 to SI 32 Line Cord 39Y7920 6218
2.8m, 12A/125V, C13 to JIS C-8303 Line cord 46M2593 A1RE
2.8m, 12A/250V, C13 to JIS C-8303 Line Cord 4L67A08357 6533
2.8m, 12A/250V, C13 to KS C8305 Line Cord 39Y7925 6219
2.8m, 13A/125V, C13 to NEMA 5-15P Line Cord 00WH545 6401
2.8m, 15A/125V, C13 to CNS 10917-3 Line Cord 81Y2374 6402
4.3m, 10A/250V, C13 to AS/NZS 3112 Line Cord 81Y2383 6574
4.3m, 10A/250V, C13 to BS 1363/A Line Cord 81Y2377 6577
4.3m, 10A/250V, C13 to CEE7-VII Line Cord 81Y2376 6572
4.3m, 10A/250V, C13 to CEI 23-16 Line Cord 81Y2380 6493
4.3m, 10A/250V, C13 to CNS 10917-3 Line Cord 81Y2389 6531
4.3m, 10A/250V, C13 to DK2-5a Line Cord 81Y2382 6575
4.3m, 10A/250V, C13 to GB 2099.1 Line Cord 81Y2378 6580
4.3m, 10A/250V, C13 to IRAM 2073 Line Cord 81Y2384 6492
4.3m, 10A/250V, C13 to IS 6538 Line Cord 81Y2386 6567
4.3m, 10A/250V, C13 to NBR 14136 Line Cord 81Y2387 6404
4.3m, 10A/250V, C13 to NEMA 6-15P Line Cord 4L67A08361 6373
4.3m, 10A/250V, C13 to SABS 164 Line Cord 81Y2379 6576
4.3m, 10A/250V, C13 to SEV 1011-S24507 Line Cord 81Y2390 6578
4.3m, 10A/250V, C13 to SI 32 Line Cord 81Y2381 6579
4.3m, 12A/125V, C13 to JIS C-8303 Line Cord 39Y7926 6335
4.3m, 12A/250V, C13 to JIS C-8303 Line Cord 4L67A08362 6495
4.3m, 12A/250V, C13 to KS C8305 Line Cord 81Y2385 6494
4.3m, 13A/125V, C13 to NEMA 5-15P Line Cord 4L67A08360 AX8A
4.3m, 15A/125V, C13 to CNS 10917-3 Line Cord 81Y2388 6530

Rack installation

The individually shipped ThinkSystem DM Series enclosures come with the following rail kits:

  • DM7100F: ThinkSystem Storage Rail Kit 4U60
  • DM240N 2U24 SFF: ThinkSystem NVMe Rail Kit 4 post
  • DM240S 2U24 SFF: ThinkSystem Storage Rack Mount Kit 2U24/4U60

The rack mount kits are listed in the following table.

Table 15. 4-post rack mount kit
Description Feature code Quantity
DM/DE 4U Adjustable Rail Kit (SIR) B742 1
Lenovo ThinkSystem Storage Rail Kit 4U60 BE28 1
Lenovo ThinkSystem NVMe Rail Kit 4 post B6Y6 1
Lenovo ThinkSystem Storage Rack Mount Kit 2U24/4U60 B38Y 1

When the ThinkSystem DM Series enclosures are factory-integrated and shipped installed in a rack cabinet, the rack mount kits that support Ship-in-Rack (SIR) capabilities are derived by the configurator.

The SIR-capable rack mount kits are listed in the following table.

Table 16. 4-post SIR rack mount kits
Description Feature code Quantity
DM/DE 4U Adjustable Rail Kit (SIR) B742 1
Lenovo ThinkSystem Storage Rail Kit 4U60 BE28 1
Lenovo ThinkSystem NVMe Adjustable Rail Kit (SIR) B6Y7 1
Lenovo ThinkSystem Storage SIR Rack Mount Kit (for 2U24 SAS enclosures) B6TH 1

The following table summarizes the rack mount kit features and specifications.

Table 17. Rack mount kit features and specifications summary
Attribute Screw-in fixed rail with adjustable depth
2U24 NVMe 2U24 SAS 2U24 NVMe SIR 2U24 SAS SIR 4U SIR/4U60
Feature code B6Y6 B38Y B6Y7 B6TH B742/BE28
Enclosure support DM240N DM240S DM240N DM240S DM7100F
Rail type Fixed (static) with adjustable depth Fixed (static) with adjustable depth Fixed (static) with adjustable depth Fixed (static) with adjustable depth Fixed (static) with adjustable depth
Tool-less installation No No No No No
In-rack maintenance Yes* Yes* Yes* Yes* Yes*
Ship-in-rack (SIR) No No Yes Yes Yes
1U PDU support Yes Yes Yes Yes Yes
0U PDU support Limited** Limited** Limited** Limited** Limited**
Rack type IBM or Lenovo 4-post, IEC standard-compliant
Mounting holes Square or round Square or round Square or round Square or round Square or round
Mounting flange
thickness
2 mm (0.08 in.) –
3.3 mm (0.13 in.)
2 mm (0.08 in.) –
3.3 mm (0.13 in.)
2 mm (0.08 in.) –
3.3 mm (0.13 in.)
2 mm (0.08 in.) –
3.3 mm (0.13 in.)
2 mm (0.08 in.) –
3.3 mm (0.13 in.)
Distance between
front and r
ear
mounting flanges^
605 mm (23.8 in.) –
812.8 mm (32 in.)
605 mm (23.8 in.) –
812.8 mm (32 in.)
605 mm (23.8 in.) –
812.8 mm (32 in.)
605 mm (23.8 in.) –
812.8 mm (32 in.)
605 mm (23.8 in.) –
812.8 mm (32 in.)

* The majority of the enclosure components can be serviced from the front or rear of the enclosure, which does not require the removal of the enclosure from the rack cabinet.
** If a 0U PDU is used, the rack cabinet must be at least 1000 mm (39.37 in.) deep for 2U24 enclosures, or at least 1200 mm (47.24 in.) deep for 4U enclosures.
^ Measured when mounted on the rack, from the front surface of the front mounting flange to the rear most point of the rail.

Physical specifications

The ThinkSystem DM7100F controller enclosure has the following dimensions and weight (approximate):

  • Height: 175 mm (6.9 in.)
  • Width: 447 mm (17.6 in.)
  • Depth: 828 mm (32.6 in.)
  • Weight (fully configured): 49.2 kg (108.5 lb)

The ThinkSystem DM240N 2U24 SFF enclosures have the following dimensions and weight (approximate):

  • Height: 87 mm (3.4 in.)
  • Width: 447 mm (17.6 in.)
  • Depth: 543 mm (21.4 in.)
  • Weight (fully configured): 30.2 kg (66.7 lb)

The ThinkSystem DM240S 2U24 SFF enclosures have the following dimensions and weight (approximate):

  • Height: 85 mm (3.4 in.)
  • Width: 449 mm (17.7 in.)
  • Depth: 484 mm (19.1 in.)
  • Weight (fully configured): 24.4 kg (53.8 lb)

Operating environment

The ThinkSystem DM7100F, DM240N 2U24 SFF, and DM240S 2U24 SFF enclosures are supported in the following environment:

  • Air temperature:
    • Operating:
      • DM7100F: 10 °C - 35 °C (50 °F - 95 °F)
      • DM240N 2U24 SFF: 5 °C - 45 °C (41 °F - 113 °F)
      • DM240S 2U24 SFF: 10 °C - 40 °C (50 °F - 104 °F)
    • Non-operating: -40 °C - +70 °C (-40 °F - 158 °F)
    • Maximum altitude: 3050 m (10,000 ft)
  • Relative humidity (non-condensing):
    • Operating:
      • DM7100F: 8% - 80%
      • DM240N 2U24 SFF: 8% - 90%
      • DM240S 2U24 SFF: 20% - 80%
    • Non-operating: 10% - 95%
  • Electrical power:
    • DM7100F
      • 100 to 127 (nominal) V AC; 50 Hz or 60 Hz; 16.12 A
      • 200 to 240 (nominal) V AC; 50 Hz or 60 Hz; 8.06 A
      • Maximum system power load: 1579 W
    • DM240N 2U24 SFF
      • 100 to 127 (nominal) V AC; 50 Hz or 60 Hz; 8.66 A
      • 200 to 240 (nominal) V AC; 50 Hz or 60 Hz; 4.33 A
      • Maximum system power load: 848 W
    • DM240S 2U24 SFF
      • 100 to 127 (nominal) V AC; 50 Hz or 60 Hz; 4.11 A
      • 200 to 240 (nominal) V AC; 50 Hz or 60 Hz; 2.05 A
      • Maximum system power load: 390 W
  • Heat dissipation:
    • DM7100F: 5388 BTU/hour
    • DM240N 2U24 SFF: 2894 BTU/hour
    • DM240S 2U24 SFF: 1331 BTU/hour
  • Acoustical noise emission:
    • DM7100F: 8.5 bels
    • DM240N 2U24 SFF: 6.4 bels
    • DM240S 2U24 SFF: 6.9 bels

Warranty upgrades and post-warranty support

The DM7100F and DM240N enclosure have a 3-year warranty and the DM240S enclosure has a 1-year or 3-year warranty based on the machine type of the system, as listed in the following table.

Table 18. Duration of standard warranty
System Machine type
1 year warranty
Machine type
3 year warranty
DM7100F Controller Enclosure - 7D25
DM240N 2U24 SFF Expansion Enclosure - 7Y62
DM240S 2U24 SFF Expansion Enclosure 7Y58 7D7Y

Our global network of regional support centers offers consistent, local-language support enabling you to vary response times and level of service to match the criticality of your support needs:

  • Standard Next Business Day – Best choice for non-essential systems requiring simple maintenance.
  • Premier Next Business Day – Best choice for essential systems requiring technical expertise from senior-level Lenovo engineers.
  • Premier 24x7 4-Hour Response – Best choice for systems where maximum uptime is critical.
  • Premier Enhanced Storage Support 24x7 4-Hour Response – Best choice for storage systems where maximum uptime is critical.

For more information, consult the brochure Lenovo Operational Support Services for Data Centers Services.

Services

Lenovo Data Center Services empower you at every stage of your IT lifecycle. From expert advisory and strategic planning to seamless deployment and ongoing support, we ensure your infrastructure is built for success. Our comprehensive services accelerate time to value, minimize downtime, and free your IT staff to focus on driving innovation and business growth.

Note: Some service options may not be available in all markets or regions. For more information, go to https://lenovolocator.com/. For information about Lenovo service upgrade offerings that are available in your region, contact your local Lenovo sales representative or business partner.

In this section:

Lenovo Advisory Services

Lenovo Advisory Services simplify the planning process, enabling customers to build future-proofed strategies in as little as six weeks. Consultants provide guidance on projects including VM migration, storage, backup and recovery, and cost management to accelerate time to value, improve cost efficiency, and build a flexibly scalable foundation.

  • Assessment Services

    An Assessment helps solve your IT challenges through an onsite, multi-day session with a Lenovo technology expert. We perform a tools-based assessment which provides a comprehensive and thorough review of a company's environment and technology systems. In addition to the technology based functional requirements, the consultant also discusses and records the non-functional business requirements, challenges, and constraints. Assessments help organizations like yours, no matter how large or small, get a better return on your IT investment and overcome challenges in the ever-changing technology landscape.

  • Design Services

    Professional Services consultants perform infrastructure design and implementation planning to support your strategy. The high-level architectures provided by the assessment service are turned into low level designs and wiring diagrams, which are reviewed and approved prior to implementation. The implementation plan will demonstrate an outcome-based proposal to provide business capabilities through infrastructure with a risk-mitigated project plan.

Lenovo Plan & Design Services

Unlock faster time to market with our tailored, strategic design workshops to align solution approaches with your business goals and technical requirements. Leverage our deep solution expertise and end-to-end delivery partnership to meet your goals efficiently and effectively.

Lenovo Deployment, Migration, and Configuration Services

Optimize your IT operations by shifting labor-intensive functions to Lenovo's skilled technicians for seamless on-site or remote deployment, configuration, and migration. Enjoy peace of mind, faster time to value, and comprehensive knowledge sharing with your IT staff, backed by our best-practice methodology.

  • Deployment Services for Storage and ThinkAgile

    A comprehensive range of remote and onsite options tailored specifically for your business needs to ensure your storage and ThinkAgile hardware are fully operational from the start.

  • Hardware Installation Services

    A full-range, comprehensive setup for your hardware, including unpacking, inspecting, and positioning components to ensure your equipment is operational and error-free for the most seamless and efficient installation experience, so you can quickly benefit from your investments.

  • DM/DG File Migration Services

    Take the burden of file migration from your IT’s shoulders. Our experts will align your requirements and business objectives to the migration plans while coordinating with your team to plan and safely execute the data migration to your storage platforms.

  • DM/DG/DE Health Check Services

    Our experts perform proactive checks of your Firmware and system health to ensure your machines are operating at peak and optimal efficiency to maximize up-time, avoid system failures, ensure the security of IT solutions and simplify maintenance.

  • Factory Integrated Services

    A suite of value-added offerings provided during the manufacturing phase of a server or storage system that reduces time to value. These services aim at improving your hardware deployment experience and enhance the quality of a standard configuration before it arrives at your facility.

Lenovo Support Services

In addition to response time options for hardware parts, repairs, and labor, Lenovo offers a wide array of additional support services to ensure your business is positioned for success and longevity. Our goal is to reduce your capital outlays, mitigate your IT risks, and accelerate your time to productivity.

  • Premier Support for Data Centers

    Your direct line to the solution that promises the best, most comprehensive level of support to help you fully unlock the potential of your data center.

  • Premier Enhanced Storage Support (PESS)

    Gain all the benefits of Premier Support for Data Centers, adding dedicated storage specialists and resources to elevate your storage support experience to the next level.

  • Committed Service Repair (CSR)

    Our commitment to ensuring the fastest, most seamless resolution times for mission-critical systems that require immediate attention to ensure minimal downtime and risk for your business. This service is only available for machines under the Premier 4-Hour Response SLA.

  • Multivendor Support Services (MVS)

    Your single point of accountability for resolution support across vast range of leading Server, Storage, and Networking OEMs, allowing you to manage all your supported infrastructure devices seamlessly from a single source.

  • Keep Your Drive (KYD)

    Protect sensitive data and maintain compliance with corporate retention and disposal policies to ensure your data is always under your control, regardless of the number of drives that are installed in your Lenovo server.

  • Technical Account Manager (TAM)

    Your single point of contact to expedite service requests, provide status updates, and furnish reports to track incidents over time, ensuring smooth operations and optimized performance as your business grows.

  • Enterprise Software Support (ESS)

    Gain comprehensive, single-source, and global support for a wide range of server operating systems and Microsoft server applications.

For more information, consult the brochure Lenovo Operational Support Services for Data Centers.

Lenovo Managed Services

Achieve peak efficiency, high security, and minimal disruption with Lenovo's always-on Managed Services. Our real-time monitoring, 24x7 incident response, and problem resolution ensure your infrastructure operates seamlessly. With quarterly health checks for ongoing optimization and innovation, Lenovo's remote active monitoring boosts end-user experience and productivity by keeping your data center's hardware performing at its best.

Lenovo Managed Services provides continuous 24x7 remote monitoring (plus 24x7 call center availability) and proactive management of your data center using state-of-the-art tools, systems, and practices by a team of highly skilled and experienced Lenovo services professionals.

Quarterly reviews check error logs, verify firmware & OS device driver levels, and software as needed. We’ll also maintain records of latest patches, critical updates, and firmware levels, to ensure you systems are providing business value through optimized performance.

Lenovo Sustainability Services

  • Asset Recovery Services

    Lenovo Asset Recovery Services (ARS) provides a secure, seamless solution for managing end-of-life IT assets, ensuring data is safely sanitized while contributing to a more circular IT lifecycle. By maximizing the reuse or responsible recycling of devices, ARS helps businesses meet sustainability goals while recovering potential value from their retired equipment. For more information, see the Asset Recovery Services offering page.

  • CO2 Offset Services

    Lenovo’s CO2 Offset Services offer a simple and transparent way for businesses to take tangible action on their IT footprint. By integrating CO2 offsets directly into device purchases, customers can easily support verified climate projects and track their contributions, making meaningful progress toward their sustainability goals without added complexity.

  • Lenovo Certified Refurbished

    Lenovo Certified Refurbished offers a cost-effective way to support IT circularity without compromising on quality and performance. Each device undergoes rigorous testing and certification, ensuring reliable performance and extending its lifecycle. With Lenovo’s trusted certification, you gain peace of mind while making a more sustainable IT choice.

Lenovo TruScale

Lenovo TruScale XaaS is your set of flexible IT services that makes everything easier. Streamline IT procurement, simplify infrastructure and device management, and pay only for what you use – so your business is free to grow and go anywhere.

Lenovo TruScale is  the unified solution that gives you simplified access to:

  • The industry’s broadest portfolio – from pocket to cloud – all delivered as a service
  • A single-contract framework for full visibility and accountability
  • The global scale to rapidly and securely build teams from anywhere
  • Flexible fixed and metered pay-as-you-go models with minimal upfront cost
  • The growth-driving combination of hardware, software, infrastructure, and solutions – all from one single provider with one point of accountability.

For information about Lenovo TruScale offerings that are available in your region, contact your local Lenovo sales representative or business partner.

Regulatory compliance

The ThinkSystem DM Series enclosures conform to the following regulations:

  • FCC Part 15, Class A; UL 60950-1
  • ICES-003, Class A; CAN/CSA-C22.2 60950-1
  • NOM
  • CE Mark (EN55032 Class A, EN55024, IEC/EN60950-1, IEC/EN62368-1); ROHS Directive 2011/65/EU
  • EAC
  • CCC GB 4943.1, GB 17625.1, GB 9254 Class A; CELP; CECP
  • VCCI, Class A
  • CNS 13438, Class A; CNS 14336-1
  • KN32/35, Class A
  • AS/NZS CISPR 22 Class A

Interoperability

Lenovo provides end-to-end storage compatibility testing to deliver interoperability throughout the network. The ThinkSystem DM7100F Unified All Flash Array supports attachment to Lenovo servers by using NVMe over Fibre Channel (NVMe/FC), NAS (NFS and CIFS/SMB), iSCSI, and Fibre Channel storage connectivity protocols.

For end-to-end storage configuration support, refer to the Lenovo Storage Interoperation Center (LSIC):
https://datacentersupport.lenovo.com/us/en/lsic

Use the LSIC to select the known components of your configuration and then get a list all other supported combinations, with details about supported hardware, firmware, operating systems, and drivers, plus any additional configuration notes. View results on screen or export them to Excel.

Cluster interconnect

The following table lists the Ethernet storage switch that can be used with the ThinkSystem DM7100F Unified All Flash Array for cluster interconnect and MetroCluster IP configurations.

Table 19. Ethernet storage switch
Description Part number
BES-53248 Ethernet Storage Switch: 16x SFP ports and 2x QSFP ports active, 2 PS (CTO only) 7D2SCTO1WW

For more information, see the BES-53248 Ethernet Storage Switch for Lenovo Product Guide:
http://lenovopress.com/lp1226

Fibre Channel SAN switches

Lenovo offers the ThinkSystem DB Series of Fibre Channel SAN switches for high-performance storage expansion. See the DB Series product guides for models and configuration options:

Rack cabinets

The following table lists the supported rack cabinets.

Table 20. Rack cabinets
ModelDescription
7D6DA007WWThinkSystem 42U Onyx Primary Heavy Duty Rack Cabinet (1200mm)
7D6DA008WWThinkSystem 42U Pearl Primary Heavy Duty Rack Cabinet (1200mm)
7D6EA009WWThinkSystem 48U Onyx Primary Heavy Duty Rack Cabinet (1200mm)
7D6EA00AWWThinkSystem 48U Pearl Primary Heavy Duty Rack Cabinet (1200mm)
93604PX42U 1200mm Deep Dynamic Rack
93604EX42U 1200mm Deep Dynamic Expansion Rack
93614PX42U 1200mm Deep Static Rack
93614EX42U 1200mm Deep Static Expansion Rack
93634PX42U 1100mm Dynamic Rack
93634EX42U 1100mm Dynamic Expansion Rack
93074RX42U Standard Rack (1000mm)
93084PX42U Enterprise Rack
93084EX42U Enterprise Expansion Rack

For specifications about these racks, see the Lenovo Rack Cabinet Reference, available from:
https://lenovopress.com/lp1287-lenovo-rack-cabinet-reference

For more information, see the list of Product Guides in the Rack cabinets category:
https://lenovopress.com/servers/options/racks

Power distribution units

The following table lists the power distribution units (PDUs) that are offered by Lenovo.

Table 21. Power distribution units
Part
number
Feature
code
Description
ANZ
ASEAN
Brazil
EET
MEA
RUCIS
WE
HTK
INDIA
JAPAN
LA
NA
PRC
0U Basic PDUs
4PU7A93176 C0QH 0U 36 C13 and 6 C19 Basic 32A 1 Phase PDU v2 Y Y Y Y Y Y Y Y Y N Y Y Y
4PU7A93169 C0DA 0U 36 C13 and 6 C19 Basic 32A 1 Phase PDU Y Y Y Y Y Y Y Y Y N Y Y Y
4PU7A93177 C0QJ 0U 24 C13/C15 and 24 C13/C15/C19 Basic 32A 3 Phase WYE PDU v2 Y Y Y Y Y Y Y Y Y Y Y Y Y
4PU7A93170 C0D9 0U 24 C13/C15 and 24 C13/C15/C19 Basic 32A 3 Phase WYE PDU Y Y Y Y Y Y Y Y Y N Y Y Y
00YJ776 ATZY 0U 36 C13/6 C19 24A 1 Phase PDU N Y Y N N N N N N Y Y Y N
00YJ779 ATZX 0U 21 C13/12 C19 48A 3 Phase PDU N N Y N N N Y N N Y Y Y N
00YJ777 ATZZ 0U 36 C13/6 C19 32A 1 Phase PDU Y Y N Y Y Y Y Y Y N N Y Y
00YJ778 AU00 0U 21 C13/12 C19 32A 3 Phase PDU Y Y N Y Y Y Y Y Y N N Y Y
0U Switched and Monitored PDUs
4PU7A93181 C0QN 0U 21 C13/C15 and 21 C13/C15/C19 Switched and Monitored 48A 3 Phase Delta PDU V2 (60A derated) N Y N N N N N Y N Y N Y N
4PU7A93174 C0D5 0U 21 C13/C15 and 21 C13/C15/C19 Switched and Monitored 48A 3 Phase Delta PDU (60A derated) N Y N Y N N Y Y N N N Y N
4PU7A93178 C0QK 0U 20 C13 and 4 C19 Switched and Monitored 32A 1 Phase PDU v2 Y Y Y Y Y Y Y Y Y N Y Y Y
4PU7A93171 C0D8 0U 20 C13 and 4 C19 Switched and Monitored 32A 1 Phase PDU Y Y Y Y Y Y Y Y Y N Y Y Y
4PU7A93182 C0QP 0U 18 C13/C15 and 18 C13/C15/C19 Switched and Monitored 63A 3 Phase WYE PDU v2 Y Y Y Y Y Y Y Y Y Y Y Y Y
4PU7A93175 C0CS 0U 18 C13/C15 and 18 C13/C15/C19 Switched and Monitored 63A 3 Phase WYE PDU Y Y Y Y Y Y Y Y Y N Y Y Y
4PU7A93180 C0QM 0U 18 C13/C15 and 18 C13/C15/C19 Switched and Monitored 32A 3 Phase WYE PDU v2 Y Y Y Y Y Y Y Y Y Y Y Y Y
4PU7A93173 C0D6 0U 18 C13/C15 and 18 C13/C15/C19 Switched and Monitored 32A 3 Phase WYE PDU Y Y Y Y Y Y Y Y Y N Y Y Y
4PU7A93179 C0QL 0U 16 C13/C15 and 16 C13/C15/C19 Switched and Monitored 24A 1 Phase PDU v2 (30A derated) N Y N N N N N Y N Y N Y N
4PU7A93172 C0D7 0U 16 C13/C15 and 16 C13/C15/C19 Switched and Monitored 24A 1 Phase PDU(30A derated) N Y N Y N N Y Y N N N Y N
00YJ783 AU04 0U 12 C13/12 C19 Switched and Monitored 48A 3 Phase PDU N N Y N N N Y N N Y Y Y N
00YJ781 AU03 0U 20 C13/4 C19 Switched and Monitored 24A 1 Phase PDU N N Y N Y N Y N N Y Y Y N
00YJ782 AU02 0U 18 C13/6 C19 Switched and Monitored 32A 3 Phase PDU Y Y Y Y Y Y Y Y Y N Y N Y
00YJ780 AU01 0U 20 C13/4 C19 Switched and Monitored 32A 1 Phase PDU Y Y Y Y Y Y Y Y Y N Y N Y
1U Switched and Monitored PDUs
4PU7A90808 C0D4 1U 18 C19/C13 Switched and monitored 48A 3P WYE PDU V2 ETL Y Y Y Y Y Y Y Y Y Y Y Y Y
4PU7A81117 BNDV 1U 18 C19/C13 switched and monitored 48A 3P WYE PDU - ETL N N N N N N N N N N N Y N
4PU7A90809 C0DE 1U 18 C19/C13 Switched and monitored 48A 3P WYE PDU V2 CE N N N N N Y Y N N N N N N
4PU7A81118 BNDW 1U 18 C19/C13 switched and monitored 48A 3P WYE PDU - CE Y Y Y Y Y Y Y Y Y N Y N Y
4PU7A90810 C0DD 1U 18 C19/C13 Switched and monitored 80A 3P Delta PDU V2 Y Y Y Y Y Y Y Y Y Y Y Y Y
4PU7A77467 BLC4 1U 18 C19/C13 Switched and Monitored 80A 3P Delta PDU N N N N N N N N N Y N Y N
4PU7A90811 C0DC 1U 12 C19/C13 Switched and monitored 32A 3P WYE PDU V2 N N N N N Y Y N N N N N N
4PU7A77468 BLC5 1U 12 C19/C13 switched and monitored 32A 3P WYE PDU Y Y Y Y Y Y Y Y Y Y Y Y Y
4PU7A90812 C0DB 1U 12 C19/C13 Switched and monitored 60A 3P Delta PDU V2 N N N N N N N N N Y N N N
4PU7A77469 BLC6 1U 12 C19/C13 switched and monitored 60A 3P Delta PDU N N N N N N N N N N N Y N
46M4002 5896 1U 9 C19/3 C13 Switched and Monitored DPI PDU Y Y Y Y Y Y Y Y Y Y Y Y Y
46M4004 5894 1U 12 C13 Switched and Monitored DPI PDU Y Y Y Y Y Y Y Y Y Y Y Y Y
46M4003 5897 1U 9 C19/3 C13 Switched and Monitored 60A 3 Phase PDU Y Y Y Y Y Y Y Y Y Y Y Y Y
46M4005 5895 1U 12 C13 Switched and Monitored 60A 3 Phase PDU Y Y Y Y Y Y Y Y Y Y Y Y Y
1U Ultra Density Enterprise PDUs (9x IEC 320 C13 + 3x IEC 320 C19 outlets)
71763NU 6051 Ultra Density Enterprise C19/C13 PDU 60A/208V/3PH N N Y N N N N N N Y Y Y N
71762NX 6091 Ultra Density Enterprise C19/C13 PDU Module Y Y Y Y Y Y Y Y Y Y Y Y Y
1U C13 Enterprise PDUs (12x IEC 320 C13 outlets)
39M2816 6030 DPI C13 Enterprise PDU Plus Module (WW) Y Y Y Y Y Y Y Y Y Y Y Y Y
39Y8941 6010 DPI C13 Enterprise PDU Module (WW) Y Y Y Y Y Y Y Y Y Y Y Y Y
1U C19 Enterprise PDUs (6x IEC 320 C19 outlets)
39Y8948 6060 DPI C19 Enterprise PDU Module (WW) Y Y Y Y Y Y Y Y Y Y Y Y Y
39Y8923 6061 DPI Three-phase 60A/208V C19 Enterprise PDU (US) N N Y N N N Y N N N Y Y N
1U Front-end PDUs (3x IEC 320 C19 outlets)
39Y8938 6002 DPI Single-phase 30A/120V Front-end PDU (US) Y Y Y Y Y Y Y Y Y Y Y Y Y
39Y8939 6003 DPI Single-phase 30A/208V Front-end PDU (US) Y Y Y Y Y Y Y Y Y Y Y Y Y
39Y8934 6005 DPI Single-phase 32A/230V Front-end PDU (International) Y Y Y Y Y Y Y Y Y Y Y Y Y
39Y8940 6004 DPI Single-phase 60A/208V Front-end PDU (US) Y N Y Y Y Y Y N N Y Y Y N
39Y8935 6006 DPI Single-phase 63A/230V Front-end PDU (International) Y Y Y Y Y Y Y Y Y Y Y Y Y
1U NEMA PDUs (6x NEMA 5-15R outlets)
39Y8905 5900 DPI 100-127V NEMA PDU Y Y Y Y Y Y Y Y Y Y Y Y Y
Line cords for 1U PDUs that ship without a line cord
40K9611 6504 4.3m, 32A/380-415V, EPDU/IEC 309 3P+N+G 3ph wye (non-US) Line Cord Y Y Y Y Y Y Y Y Y Y Y Y Y
40K9612 6502 4.3m, 32A/230V, EPDU to IEC 309 P+N+G (non-US) Line Cord Y Y Y Y Y Y Y Y Y Y Y Y Y
40K9613 6503 4.3m, 63A/230V, EPDU to IEC 309 P+N+G (non-US) Line Cord Y Y Y Y Y Y Y Y Y Y Y Y Y
40K9614 6500 4.3m, 30A/208V, EPDU to NEMA L6-30P (US) Line Cord Y Y Y Y Y Y Y Y Y Y Y Y Y
40K9615 6501 4.3m, 60A/208V, EPDU to IEC 309 2P+G (US) Line Cord N N Y N N N Y N N Y Y Y N
40K9617 6505 4.3m, 32A/230V, Souriau UTG Female to AS/NZ 3112 (Aus/NZ) Line Cord Y Y Y Y Y Y Y Y Y Y Y Y Y
40K9618 6506 4.3m, 32A/250V, Souriau UTG Female to KSC 8305 (S. Korea) Line Cord Y Y Y Y Y Y Y Y Y Y Y Y Y

For more information, see the Lenovo Press documents in the PDU category:
https://lenovopress.com/servers/options/pdu

Uninterruptible power supply units

The following table lists the uninterruptible power supply (UPS) units that are offered by Lenovo.

Table 22. Uninterruptible power supply units
Part number Description
Rack-mounted or tower UPS units - 100-125VAC
7DD5A001WW RT1.5kVA 2U Rack or Tower UPS-G2 (100-125VAC)
55941AX RT1.5kVA 2U Rack or Tower UPS (100-125VAC)
55942AX RT2.2kVA 2U Rack or Tower UPS (100-125VAC)
7DD5A003WW RT3kVA 2U Rack or Tower UPS-G2 (100-125VAC)
55943AX RT3kVA 2U Rack or Tower UPS (100-125VAC)
Rack-mounted or tower UPS units - 200-240VAC
7DD5A002WW RT1.5kVA 2U Rack or Tower UPS-G2 (200-240VAC)
55941KX RT1.5kVA 2U Rack or Tower UPS (200-240VAC)
55942KX RT2.2kVA 2U Rack or Tower UPS (200-240VAC)
7DD5A005WW RT3kVA 2U Rack or Tower UPS-G2 (200-240VAC)
55943KX RT3kVA 2U Rack or Tower UPS (200-240VAC)
7DD5A007WW RT5kVA 3U Rack or Tower UPS-G2 (200-240VAC)
55945KX RT5kVA 3U Rack or Tower UPS (200-240VAC)
7DD5A008WW RT6kVA 3U Rack or Tower UPS-G2 (200-240VAC)
55946KX RT6kVA 3U Rack or Tower UPS (200-240VAC)
55948KX RT8kVA 6U Rack or Tower UPS (200-240VAC)
7DD5A00AWW RT11kVA 6U Rack or Tower UPS-G2 (200-240VAC)
55949KX RT11kVA 6U Rack or Tower UPS (200-240VAC)
55943KT† ThinkSystem RT3kVA 2U Standard UPS (200-230VAC) (2x C13 10A, 2x GB 10A, 1x C19 16A outlets)
55943LT† ThinkSystem RT3kVA 2U Long Backup UPS (200-230VAC) (2x C13 10A, 2x GB 10A, 1x C19 16A outlets)
55946KT† ThinkSystem RT6kVA 5U UPS (200-230VAC) (2x C13 10A outlets, 1x Terminal Block output)
5594XKT† ThinkSystem RT10kVA 5U UPS (200-230VAC) (2x C13 10A outlets, 1x Terminal Block output)
Rack-mounted or tower UPS units - 380-415VAC
55948PX RT8kVA 6U 3:1 Phase Rack or Tower UPS (380-415VAC)
55949PX RT11kVA 6U 3:1 Phase Rack or Tower UPS (380-415VAC)

† Only available in China and the Asia Pacific market.

For more information, see the list of Product Guides in the UPS category:
https://lenovopress.com/servers/options/ups

Lenovo Financial Services

Why wait to obtain the technology you need now? No payments for 90 days and predictable, low monthly payments make it easy to budget for your Lenovo solution.

  • Flexible

    Our in-depth knowledge of the products, services and various market segments allows us to offer greater flexibility in structures, documentation and end of lease options.

  • 100% Solution Financing

    Financing your entire solution including hardware, software, and services, ensures more predictability in your project planning with fixed, manageable payments and low monthly payments.

  • Device as a Service (DaaS)

    Leverage latest technology to advance your business. Customized solutions aligned to your needs. Flexibility to add equipment to support growth. Protect your technology with Lenovo's Premier Support service.

  • 24/7 Asset management

    Manage your financed solutions with electronic access to your lease documents, payment histories, invoices and asset information.

  • Fair Market Value (FMV) and $1 Purchase Option Leases

    Maximize your purchasing power with our lowest cost option. An FMV lease offers lower monthly payments than loans or lease-to-own financing. Think of an FMV lease as a rental. You have the flexibility at the end of the lease term to return the equipment, continue leasing it, or purchase it for the fair market value. In a $1 Out Purchase Option lease, you own the equipment. It is a good option when you are confident you will use the equipment for an extended period beyond the finance term. Both lease types have merits depending on your needs. We can help you determine which option will best meet your technological and budgetary goals.

Ask your Lenovo Financial Services representative about this promotion and how to submit a credit application. For the majority of credit applicants, we have enough information to deliver an instant decision and send a notification within minutes.

Seller training courses

The following sales training courses are offered for employees and partners (login required). Courses are listed in date order.

  1. How to Attach Services for ThinkSystem DM Using DCSC
    2024-12-23 | 20 minutes | Employees and Partners
    Details
    How to Attach Services for ThinkSystem DM Using DCSC

    The goal of this training is to review services for ThinkSystem DM products, professional and support services, support levels, and recommended options. By the end of this course, you will be able to summarize the professional services for ThinkSystem DM, identify the levels of maintenance support for the DM series, and recognize the steps required to attach services to DM products.

    Published: 2024-12-23
    Length: 20 minutes

    Start the training:
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning

    Course code: DSVC122r4
  2. Lenovo Client Virtualization Solutions
    2024-11-22 | 20 minutes | Employees and Partners
    Details
    Lenovo Client Virtualization Solutions

    This training provides tech sellers and partners with the details of the customer challenges and needs that make the case for the Lenovo client virtualization solutions.

    By the end of this course you will:
    • Learn the components that makeup our solutions
    • Cover the details of the three LCV (Lenovo Client Virtualization) offerings
    • Discover when they are used and how they benefit customers

    Published: 2024-11-22
    Length: 20 minutes

    Start the training:
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning

    Course code: DCV213r2
  3. ThinkSystem DM and DE Series Technical Overview
    2024-10-15 | 30 minutes | Employees and Partners
    Details
    ThinkSystem DM and DE Series Technical Overview

    This course provides a technical overview of the ThinkSystem DM and DE series products. Course DDMO101 – Lenovo ThinkSystem DM & DE Series Overview is recommended prior to this course.
    By the end of this course, you should be able to:
    - Describe the Lenovo portfolio for the DM and DE storage systems
    - Explain features of the DM series ONTAP software
    - Explain features of the ThinkSystem SAN Manager

    Published: 2024-10-15
    Length: 30 minutes

    Start the training:
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning

    Course code: DDMT100r2
  4. Lenovo ThinSystem DG/DM Storage Series Portfolio Overview
    2024-09-10 | 60 minutes | Employees and Partners
    Details
    Lenovo ThinSystem DG/DM Storage Series Portfolio Overview

    This course builds on what you’ve learned in the Data Management Overview course. The course will help position the Lenovo ThinkSystem DG and DM series storage products. Completing this course will help you:
    - understand the advantages of each product line and
    - understand the key features and relate them to a range of customer business needs, whether small-scale or enterprise-level storage needs

    Published: 2024-09-10
    Length: 60 minutes

    Start the training:
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning

    Course code: DDMO103
  5. Lenovo Data Center Product Portfolio
    2024-05-29 | 20 minutes | Employees and Partners
    Details
    Lenovo Data Center Product Portfolio

    This course introduces the Lenovo data center portfolio, and covers servers, storage, storage networking, and software-defined infrastructure products. After completing this course about Lenovo data center products, you will be able to identify product types within each data center family, describe Lenovo innovations that this product family or category uses, and recognize when a specific product should be selected.

    Published: 2024-05-29
    Length: 20 minutes

    Start the training:
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning

    Course code: SXXW1110r7
  6. VTT Data Management How to sell storage - April 2024
    2024-04-10 | 60 minutes | Employees Only
    Details
    VTT Data Management How to sell storage - April 2024

    In this course, you will know:

    - Why do we sell storage?
    - What are the basics you need to get an opportunity rolling?
    - Why Lenovo for Storage?
    - What is happening in the market today?
    - How to determine traction?

    Published: 2024-04-10
    Length: 60 minutes

    Start the training:
    Employee link: Grow@Lenovo

    Course code: DVDAT209
  7. Lenovo Data Backup and Recovery Solution Overview
    2024-03-25 | 40 minutes | Employees and Partners
    Details
    Lenovo Data Backup and Recovery Solution Overview

    The goal of this course is to give Lenovo sellers and business partners an overview of the Data Backup and Recovery solution. This course includes general information about backup, archive, disaster, nomenclature and key terms for back and recovery, and Lenovo features and alliance partners software.

    Published: 2024-03-25
    Length: 40 minutes

    Start the training:
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning

    Course code: DSOLO200
  8. ONTAP Technical Positioning
    2024-03-14 | 45 minutes | Employees and Partners
    Details
    ONTAP Technical Positioning

    This course focuses on enabling you to interpret the technical market trends and challenges that ONTAP customers face. You also learn to ask qualifying questions that identify which industries, companies, and customer contacts are appropriate targets for ONTAP software. Module two covers explaining ONTAP features and functionality and enabling you to strengthen ONTAP marketing claims with technical details.
    Learning Objectives:
    • Interpret the technical market trends and challenges that ONTAP customers face
    • Ask qualifying questions that identify which industries, companies, and customer contacts are appropriate targets for ONTAP software
    • Explain ONTAP features and functionality
    • Strengthen ONTAP marketing claims with technical details

    Published: 2024-03-14
    Length: 45 minutes

    Start the training:
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning

    Course code: DDMT200r2
  9. Data management Overview
    2024-03-14 | 25 minutes | Employees and Partners
    Details
    Data management Overview

    After completing this course you will be able to:
    1. Know more about the data management trends and challenges
    2. Understand the data management portfolio
    3. Find out how data drives business value

    Published: 2024-03-14
    Length: 25 minutes

    Start the training:
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning

    Course code: DSTOO201
  10. VTT ONTAP 9.14.1 and Bundle Change Update - February 2024
    2024-03-07 | 25 minutes | Employees and Partners
    Details
    VTT ONTAP 9.14.1 and Bundle Change Update - February 2024

    In this course, you will know more about:
    - The new Features of ONTAP 9.14.1 update
    - ONTAP Bundle Update

    Published: 2024-03-07
    Length: 25 minutes

    Start the training:
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning

    Course code: DVDAT207
  11. Selling ONTAP
    2024-03-06 | 22 minutes | Employees and Partners
    Details
    Selling ONTAP

    In this course, you learn how ONTAP software helps your customers simplify data management, access and protect their data across clouds, and future-proof their environments.
    Learning objectives:
    • Explain the value of ONTAP data-management software
    • Describe the features and benefits of ONTAP 9 software
    • Effectively position ONTAP software to your customers

    Published: 2024-03-06
    Length: 22 minutes

    Start the training:
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning

    Course code: DDMO102
  12. Family Portfolio: Storage
    2024-02-02 | 15 minutes | Employees and Partners
    Details
    Family Portfolio: Storage

    This course covers products in the Lenovo storage portfolio, from storage servers to direct-access storage through storage systems.
    After completing this course about the Storage family, the learner will be able to identify products within the family, describe the features of this product family, and recognize when a specific product should be selected.

    Published: 2024-02-02
    Length: 15 minutes

    Start the training:
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning

    Course code: SXSW1201r16
  13. Competing with ONTAP Fundamentals
    2024-02-01 | 16 minutes | Employees and Partners
    Details
    Competing with ONTAP Fundamentals

    Competing with ONTAP Fundamentals is intended to help sellers and partners be able to discuss the ONTAP Fundamentals license and how to position DM Series Storage with ONTAP Fundamentals versus competition.


    Objectives:
    Identify How to Position DM Series Storage with ONTAP Fundamentals Vs. Competition
    Discuss the ONTAP Fundamentals License

    Published: 2024-02-01
    Length: 16 minutes

    Start the training:
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning

    Course code: DSTOC100
  14. VTT ONTAP 9.13.1 and Bundle Change Update - November 2023
    2023-11-14 | 60 minutes | Employees Only
    Details
    VTT ONTAP 9.13.1 and Bundle Change Update - November 2023

    In this course, you will know more about:
    - The new Features of ONTAP 9.13.1 update
    - ONTAP Bundle Update

    Published: 2023-11-14
    Length: 60 minutes

    Start the training:
    Employee link: Grow@Lenovo

    Course code: DVDAT205
  15. ONTAP Data Protection Fundamentals
    2023-11-02 | 76 minutes | Employees and Partners
    Details
    ONTAP Data Protection Fundamentals

    In this course, we discuss the integrated data protection features in ONTAP data-management software. We also discuss the tools and software that you use to manage and monitor the data protection features. You learn about cluster peering, storage virtual machine (or SVM) peering, and data protection relationships. You also learn about the architecture and functionality of the Snapshot, SnapMirror, SnapVault, and SyncMirror technologies.

    Course DDMT203 – ONTAP SAN Fundamentals is a prerequisite.


    Course Objectives:
    • Describe the integrated data protection features in ONTAP data-management software
    • Identify the tools and software that you use to manage and monitor ONTAP data protection features
    • Describe cluster peering, storage virtual machine (SVM) peering, and data protection relationships
    • Explain the architecture and functionality of the Snapshot, SnapMirror, SnapVault, and SyncMirror technologies

    Published: 2023-11-02
    Length: 76 minutes

    Start the training:
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning

    Course code: DDMT204r2
  16. Lenovo DM Series Data Efficiency Guarantee
    2023-10-09 | 10 minutes | Employees Only
    Details
    Lenovo DM Series Data Efficiency Guarantee

    The Data Efficiency Guarantee offers Lenovo customers an agreed amount of capacity savings. If the Lenovo solution does not meet the terms agreed to in the Guarantee, Lenovo will remediate.

    Course Objectives:
    • Define the Lenovo DM Series Data Efficiency Guarantee
    • Understand how the guarantee works
    • Describe the sales process for delivering and tracking the guarantee

    Published: 2023-10-09
    Length: 10 minutes

    Start the training:
    Employee link: Grow@Lenovo

    Course code: DDMC100
  17. ThinkSystem DM Series Technical 200 - ONTAP Data Management Fundamentals
    2023-10-03 | 90 minutes | Employees and Partners
    Details
    ThinkSystem DM Series Technical 200 - ONTAP Data Management Fundamentals

    This course focuses on enabling you to manage and provision ONTAP systems and it is part of the ISG Sales education supporting our ThinkSystem DM and DE Series education. Before taking this course, you should have completed the ThinkSystem DM and DE Series Overview as well as the ThinkSystem DM and DE Series Technical Overview 100. 200 level technical knowledge is provided separately for the DM and DE Series products.

    This course focuses on enabling you to do the following:

    - Describe the consumers of resources and management requirements
    - Describe the user and administrative roles that manage resources
    - List the various data management products you can use to manage ONTAP systems
    - Define the resources that are commonly provisioned
    - Describe various methods and tools that can be used to provision resources

    Published: 2023-10-03
    Length: 90 minutes

    Start the training:
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning

    Course code: DDMT205
  18. ThinkSystem DM Series Technical 200 - ONTAP Cluster Fundamentals
    2023-10-02 | 135 minutes | Employees and Partners
    Details
    ThinkSystem DM Series Technical 200 - ONTAP Cluster Fundamentals

    This course identifies and describes the components that make up a cluster. It also describes the supported cluster configurations and details the steps that are required to create and configure a cluster as well as discusses the physical storage components and the Write Anywhere File Layout file system, also known as the WAFL file system. Course DDMT200 – ONTAP Technical Positioning is a prerequisite.

    By the end of this course, you will be able to:

    -Identify the components that make up a cluster
    -Describe the cluster configurations that are supported
    -Create and configure a cluster
    -Describe the physical storage components
    -Describe the Write Anywhere File Layout (WAFL) file system

    Published: 2023-10-02
    Length: 135 minutes

    Start the training:
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning

    Course code: DDMT201
  19. Assessment for Lenovo ThinkSystem DM and DE Series Technical Overview 100
    2023-10-02 | 30 minutes | Partners Only
    Details
    Assessment for Lenovo ThinkSystem DM and DE Series Technical Overview 100

    This is the online assessment for the virtual-live course Lenovo ThinkSystem DM and DE Series Technical Overview 100 (DDMT100).

    Your objective for this assessment is to complete the 15-question quiz with the minimum passing score of 80%.

    Published: 2023-10-02
    Length: 30 minutes

    Start the training:
    Partner link: Lenovo Partner Learning

    Course code: DDMT101
  20. ThinkSystem DM Series Technical 200 Assessment
    2023-09-28 | 15 minutes | Employees and Partners
    Details
    ThinkSystem DM Series Technical 200 Assessment

    This is the assessment for the DM Series Technical 200 training

    Published: 2023-09-28
    Length: 15 minutes

    Start the training:
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning

    Course code: DDMT206
  21. VEEAM Solutions Sales Training
    2023-09-27 | 20 minutes | Employees and Partners
    Details
    VEEAM Solutions Sales Training

    In this course you will learn about Hyper-availability for the Always-On Enterprise.

    By the end of this training, you should be able to:

    Identify and explain the core products and solutions offered by Veeam.
    Explain the key benefits and value propositions of integrating Veeam solutions with Lenovo products.

    Published: 2023-09-27
    Length: 20 minutes

    Start the training:
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning

    Course code: DSTOO100
  22. ONTAP SAN Fundamentals
    2023-09-26 | 60 minutes | Employees and Partners
    Details
    ONTAP SAN Fundamentals

    In this course, you learn how ONTAP provides block access to a host by using SAN protocols. You learn about LUNs and how to map them to a host to enable read and write access. You also learn about multipathing techniques that can improve availability and performance.
    The course objectives are:
    1. Describe how ONTAP provides block access to a host
    2. Explain how SANs use the iSCSI, FC, and FCoE protocols to transport data between a host and storage system
    3. List the steps that are required to access a LUN in a storage virtual machine (SVM) from the host
    4. Describe multipathing between the host and a cluster

    Published: 2023-09-26
    Length: 60 minutes

    Start the training:
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning

    Course code: DDMT203
  23. ONTAP NAS Fundamentals
    2023-09-25 | 45 minutes | Employees and Partners
    Details
    ONTAP NAS Fundamentals

    This course describes how ONTAP provides file access to clients. The course also explains how you use the NFS and SMB protocols to access files, how you access files over a network, and how you use load-balancing techniques to improve performance.
    Course objectives:
    1. Describe how ONTAP provides file access to clients
    2. Use the NFS protocol to access files
    3. Use the SMB protocol to access files
    4. Access files over a network and use the load-balancing features of ONTAP

    Published: 2023-09-25
    Length: 45 minutes

    Start the training:
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning

    Course code: DDMT202
  24. VEEAM Hyper-Availability Integration with ThinkSystem DM Series
    2023-09-20 | 20 minutes | Employees and Partners
    Details
    VEEAM Hyper-Availability Integration with ThinkSystem DM Series

    In this course you will learn about VEEAM Hyper-Availability for ThinkSystem DM Series

    Published: 2023-09-20
    Length: 20 minutes

    Start the training:
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning

    Course code: DSTOO300
  25. VTT The Benefits of Scale Out Clustering with DM/DG - September 2023
    2023-09-12 | 60 minutes | Employees Only
    Details
    VTT The Benefits of Scale Out Clustering with DM/DG - September 2023

    In this course, you will know more about:
    - What is scale out?
    - Hardware benefits
    - Administrative benefits
    - Scale out Features

    Published: 2023-09-12
    Length: 60 minutes

    Start the training:
    Employee link: Grow@Lenovo

    Course code: DVDAT204
  26. Storage Masters - Unified Storage on DM Series
    2023-07-28 | 14 minutes | Employees and Partners
    Details
    Storage Masters - Unified Storage on DM Series

    Storage Masters is a multi-module education series. It is intended to help sellers and partners be able to discuss various storage topics that you will encounter in the field and how to position the valuable features of the DM Series within these conversations.

    By the end of this training, you should be able to:
    • Describe the business challenges resolved by the unified storage for the ThinkSystem DM series.
    • Learn about the technology implemented on the DM series of storage arrays.
    • Find out what are the benefits of the technology and positioning.

    Published: 2023-07-28
    Length: 14 minutes

    Start the training:
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning

    Course code: DSTOT2006
  27. VTT: SAP HANA Transition and Refresh Opportunity - July 2023
    2023-07-14 | 60 minutes | Employees Only
    Details
    VTT: SAP HANA Transition and Refresh Opportunity - July 2023

    In this session, we cover:
    - What Next for SAP Clients?
    - Lenovo Opportunity
    - Lenovo Portfolio for SAP Solutions
    - RISE with SAP

    Published: 2023-07-14
    Length: 60 minutes

    Start the training:
    Employee link: Grow@Lenovo

    Course code: DVDAT202
  28. Storage Masters - DM Series - Data Security
    2023-06-30 | 14 minutes | Employees and Partners
    Details
    Storage Masters - DM Series - Data Security

    Storage Masters is a multi-module education series. It is intended to help sellers and partners be able to discuss various storage topics that you will encounter in the field and how to position the valuable features of the DM Series within these conversations.

    Published: 2023-06-30
    Length: 14 minutes

    Start the training:
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning

    Course code: DSTOT2005
  29. Partner Technical Webinar - DE & DM Storage Refresher
    2023-05-23 | 60 minutes | Employees and Partners
    Details
    Partner Technical Webinar - DE & DM Storage Refresher

    In this 60-minute replay, Mark Clayton, Lenovo Storage Engineer, reviewed the ThinkSystem DM Storage Array and the ThinkSystem DE Storage Array.

    Published: 2023-05-23
    Length: 60 minutes

    Start the training:
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning

    Course code: 051923
  30. Benefits and the positioning of Lenovo ThinkSystem file offerings with WEKA, DSS, and DM+ONTAP
    2023-05-08 | 10 minutes | Employees and Partners
    Details
    Benefits and the positioning of Lenovo ThinkSystem file offerings with WEKA, DSS, and DM+ONTAP

    Course objectives:
    1. Learn about file storage
    2. Understand the different types of storage
    3. Recognize the Lenovo data management portfolio

    Published: 2023-05-08
    Length: 10 minutes

    Start the training:
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning

    Course code: DSOLS207
  31. Lenovo ThinkSystem DM and DE Series Overview
    2023-02-15 | 25 minutes | Employees and Partners
    Details
    Lenovo ThinkSystem DM and DE Series Overview

    This course focuses on enabling you to identify current business and technology challenges for your customers and position the ThinkSystem DM and DE series products, based on the needs of your customers.
    The main objectives are:
    • Identify current business and technology challenges for your customers
    • Position the Lenovo ThinkSystem DM and DE Series products based on the needs of your customers

    Published: 2023-02-15
    Length: 25 minutes

    Start the training:
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning

    Course code: DDMO101r5
  32. Storage Masters - DM Series Performance
    2023-02-15 | 15 minutes | Employees and Partners
    Details
    Storage Masters - DM Series Performance

    Storage Masters is a multi-module education series. It is intended to help sellers and partners be able to discuss various storage topics that you will encounter in the field and how to position the valuable features of the DM Series within these conversations.

    By the end of this course, you will be able to:
    • Understand the key business challenges that companies face with their data storage solutions
    • Describe DM Series features
    • Explain the benefit of DM Series features to customers

    Published: 2023-02-15
    Length: 15 minutes

    Start the training:
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning

    Course code: DSTOT2004r3
  33. Storage Masters - Hybrid Cloud for DM Series
    2023-02-01 | 30 minutes | Employees and Partners
    Details
    Storage Masters - Hybrid Cloud for DM Series

    Storage Masters is a multi-module education series. It is intended to help sellers and partners be able to discuss various storage topics that you will encounter in the field and how to position the valuable features of the DM Series within these conversations.

    Published: 2023-02-01
    Length: 30 minutes

    Start the training:
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning

    Course code: DSTOT2003
  34. ONTAP Fundamentals Bundle
    2023-02-01 | 15 minutes | Employees and Partners
    Details
    ONTAP Fundamentals Bundle

    ONTAP Fundamentals is intended to help sellers and partners be able to discuss the ONTAP Fundamentals license. By the end of this training, you should be able to position ONTAP Fundamentals within the marketplace; describe the ONTAP bundle; identify when to use the ONTAP Bundle in an opportunity; and determine when to use ONTAP Premium in an opportunity.

    Published: 2023-02-01
    Length: 15 minutes

    Start the training:
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning

    Course code: DSTOF200
  35. Lenovo DM Storage Series - Hybrid Cloud Solutions
    2022-11-04 | 15 minutes | Employees Only
    Details
    Lenovo DM Storage Series - Hybrid Cloud Solutions

    This course focuses on enabling you to:
    • Identify DM Series Hybrid Cloud Solutions
    • Describe features of the DM Series FabricPool capability
    • Describe features of the DM Series Cloud Volumes ONTAP capability.

    Published: 2022-11-04
    Length: 15 minutes

    Start the training:
    Employee link: Grow@Lenovo

    Course code: DDM201
  36. Data Infrastructure Management - DM Series Storage
    2022-10-28 | 25 minutes | Employees Only
    Details
    Data Infrastructure Management - DM Series Storage

    This course provides a technical overview of the ThinkSystem DM series products. Course DDMO101 – Lenovo ThinkSystem DM & DE Series Overview is recommended prior to this course.

    By the end of this course, you should be able to:
    • Recognize the components of the Lenovo Data Management portfolio
    • Discuss the features of the Lenovo Data Management components
    • Describe the features of the SnapCenter software components

    Published: 2022-10-28
    Length: 25 minutes

    Start the training:
    Employee link: Grow@Lenovo

    Course code: DDM200
  37. Benefits of All-Flash Arrays
    2022-05-03 | 10 minutes | Employees and Partners
    Details
    Benefits of All-Flash Arrays

    This course starts by comparing and contrasting HDDs and SSDs, and lists the advantages of SSDs in all-flash arrays. Specific advanced features made possible by SSDs in AFAs are discussed, and workloads that are well-suited to AFAs are described.

    Published: 2022-05-03
    Length: 10 minutes

    Start the training:
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning

    Course code: SXXW1232

1-10 of 37 courses.

Related product families

Product families related to this document are the following:

Trademarks

Lenovo and the Lenovo logo are trademarks or registered trademarks of Lenovo in the United States, other countries, or both. A current list of Lenovo trademarks is available on the Web at https://www.lenovo.com/us/en/legal/copytrade/.

The following terms are trademarks of Lenovo in the United States, other countries, or both:
Lenovo®
ThinkAgile®
ThinkSystem®
XClarity®

The following terms are trademarks of other companies:

Intel® is a trademark of Intel Corporation or its subsidiaries.

Linux® is the trademark of Linus Torvalds in the U.S. and other countries.

Microsoft®, Excel®, Internet Explorer®, Windows Server®, and Windows® are trademarks of Microsoft Corporation in the United States, other countries, or both.

Other company, product, or service names may be trademarks or service marks of others.