Abstract

The BES-53248 Ethernet Storage Switch for Lenovo is an IP SAN storage switch that is designed and optimized to provide dedicated Ethernet storage fabric, including storage clustering in the data center and between the local and remote sites, and it offers 10/25/40/100 Gb Ethernet connectivity with "pay-as-you-grow" scalability. The switch delivers line-rate, high-bandwidth lossless switching that keeps storage data traffic moving without delays, while the hot-swap redundant power supplies and fans (along with numerous high-availability software features) help provide high availability for business-critical traffic.

Running the Broadcom industry-leading Enterprise Fabric Operating System (EFOS), the BES-53248 Ethernet Storage Switches for Lenovo deliver production-ready networking software customized for IP storage solutions with advanced networking features and protocols required in the modern storage infrastructure for data center applications.

This product guide provides essential technical and pre-sales information on the BES-53248 Ethernet Storage Switch for Lenovo, its key features and specifications, components and options, and configuration guidelines.

This guide is intended for technical specialists, sales specialists, sales engineers, IT architects, and other IT professionals who want to learn more about the BES-53248 Ethernet Storage Switch for Lenovo and consider its use in IT solutions.

Change History

Changes in the March 26, 2024 update:

  • Clarified warranty service upgrades available under - Warranty and support section:
    • 9x5 service coverage with next business day onsite response
    • 24x7 service coverage with 4-hour onsite response

Introduction

The BES-53248 Ethernet Storage Switch for Lenovo is an IP SAN storage switch that is designed and optimized to provide dedicated Ethernet storage fabric, including storage clustering in the data center and between the local and remote sites, and it offers 10/25/40/100 Gb Ethernet connectivity with "pay-as-you-grow" scalability. The switch delivers line-rate, high-bandwidth lossless switching that keeps storage data traffic moving without delays, while the hot-swap redundant power supplies and system fans (along with numerous high-availability software features) help provide high availability for business-critical traffic.

Running the Broadcom industry-leading Enterprise Fabric Operating System (EFOS), the BES-53248 Ethernet Storage Switches for Lenovo deliver production-ready networking software customized for IP storage solutions with advanced networking features and protocols required in the modern storage infrastructure for data center applications.

The BES-53248 Ethernet Storage Switch for Lenovo has 48x SFP28/SFP+ ports that support 10 GbE SFP+ and 25 GbE SFP28 optical transceivers and direct attach copper (DAC) cables. The switch also offers 8x QSFP28/QSFP+ ports that support 40 GbE QSFP+ and 100 GbE QSFP28 optical transceivers and DAC cables.

The BES-53248 Ethernet Storage Switches for Lenovo are ideally suited for enterprises of various sizes with all flash and NVMe IP Ethernet storage environments, as well as clustered storage deployments.

The BES-53248 Ethernet Storage Switch for Lenovo is shown in the following figure.

BES-53248 Ethernet Storage Switch for Lenovo
Figure 1. BES-53248 Ethernet Storage Switch for Lenovo

Did you know?

The BES-53248 Ethernet Storage Switches for Lenovo are certified for MetroCluster IP deployments of the Lenovo ThinkSystem DM Series storage arrays.

The BES-53248 Ethernet Storage Switches for Lenovo are optimized for quick and easy deployments by tightly integrating with the hardware.

The BES-53248 Ethernet Storage Switches for Lenovo undergo extensive quality assurance testing to verify functional and system performance to accommodate the ever-increasing demands on storage network devices.

Key features

The BES-53248 Ethernet Storage Switch for Lenovo offers the following features and benefits:

  • Provides validated, certified network interconnect for deploying clustered storage and MetroCluster IP configurations with the Lenovo ThinkSystem DM Series storage arrays. 
  • Offers high scalability in a dense, 1U network switch with 48x SFP28/SFP+ ports and 8x QSFP28/QSFP+ ports to support IP storage clustering, iSCSI, NVMe over RoCE, and flash-based storage environments.
  • Enables cost-effective “pay-as-you-grow” scalability from 18 to 56 ports with Ports On Demand (POD).
  • Increases performance and flexibility for demanding storage workloads with a combination of ultra-low latency and non-blocking, line-rate switching and support for 10/25/40/100 Gbps Ethernet links.
  • Accelerates communications with lower latency across clustered applications and storage arrays with RDMA over Converged Ethernet (RoCE) and iWARP.
  • Optimizes IP storage fabric behavior and ensures sufficient bandwidth for mission-critical applications with congestion management and advanced traffic scheduling.
  • Simplifies deployment of large-scale environments by enabling a switch to automatically provision itself using the resources available on the network, without manual intervention, with Zero Touch Provisioning (ZTP) and AutoInstall.
  • Supplies a rich set of standard features at no extra cost, including scalability and performance, availability and redundancy, virtual local area networks, security, quality of service, IPv4/IPv6 routing and host management, virtualization, data center fabric, monitoring, and management.
  • Runs Enterprise Fabric OS, which deliver production-ready networking software customized for IP storage solutions with advanced networking features and protocols required in the modern storage infrastructure for data center applications.
  • Maximizes resiliency with redundant hot-swap system fans and power supplies, along with numerous high-availability software features.
  • Allows switch management integration into third-party management applications by supporting the REpresentational State Transfer (REST) Application Program Interface (API).

Components and connectors

The following figure shows the front (port-side) panel of the BES-53248 Ethernet Storage Switch for Lenovo.

Front panel of the BES-53248 Ethernet Storage Switch for Lenovo
Figure 2. Front panel of the BES-53248 Ethernet Storage Switch for Lenovo

The front panel of the BES-53248 Ethernet Storage Switch for Lenovo includes the following components:

  • 48x SFP28/SFP+ ports to attach SFP28/SFP+ transceivers or DAC cables for 25 Gb or 10 Gb Ethernet connections.
  • 8x QSFP28/QSFP+ ports to attach QSFP28/QSFP+ transceivers or DAC cables for 100 Gb or 40 Gb Ethernet connections.
  • One RJ-45 10/100/1000 Mb Ethernet port for out-of-band management.
  • One RJ-45 RS-232 console port that provides another means to configure the switch.
  • One USB 2.0 port for mass storage devices.
  • LEDs that display the status of the switch and the network.

The following figure shows the rear (non-port-side) panel of the BES-53248 Ethernet Storage Switch for Lenovo.

Rear panel of the BES-53248 Ethernet Storage Switch for Lenovo
Figure 3. Rear panel of the BES-53248 Ethernet Storage Switch for Lenovo

The rear panel of the BES-53248 Ethernet Storage Switch for Lenovo includes the following components:

  • Two redundant hot-swap 750 W AC power supplies (each with the IEC 320-C14 power connector).
  • Six N+2 redundant hot-swap system fans.

System specifications

The following table lists the BES-53248 Ethernet Storage Switch for Lenovo system specifications.

Note: The supported hardware options and software features listed in this product guide are based on the Enterprise Fabric Operating System (EFOS) version 3.4.4.6. For details about current and future EFOS software releases that introduce support for certain hardware options and software features, refer to the Release Notes for the particular software release.

Table 1. BES-53248 Ethernet Storage Switch for Lenovo system specifications
Attribute Specification
Form factor 1U rack mount
Ports
  • 48x SFP ports (SFP28/SFP+)
  • 8x QSFP ports (QSFP28/QSFP+)
Media types
  • 10 Gb Ethernet SFP+:
    • 10 GbE short-range (SR) SFP+ transceivers
    • 10 GbE long-range (LR) SFP+ transceivers
    • 10 GbE SFP+ DAC cables
  • 25 Gb Ethernet SFP28:
    • 25 GbE SR SFP28 transceivers
    • 25 GbE SFP28 DAC cables
  • 40 Gb Ethernet QSFP+:
    • 40 GbE short-range (eSR4) QSFP+ transceivers
    • 40 GbE QSFP+ to QSFP+ DAC cables
  • 100 Gb Ethernet QSFP28:
    • 100 GbE short-range (SR4) QSFP28 transceivers
    • 100 GbE QSFP28 to QSFP28 DAC cables
Port speeds
  • 10 GbE SFP+ transceivers and DAC cables: 10 Gbps
  • 25 GbE SFP28 transceivers and DAC cables: 25 Gbps
  • 40 GbE QSFP+ eSR4 transceivers and DAC cables: 40 GbE
  • 100 GbE QSFP28 SR4 transceivers and DAC cables: 100 Gbps
Note: SFP28/SFP+ ports are combined into 12 consecutive 4-port groups: Ports 1-4, 5-8, 9-12, 13-16, 17-20, 21-24, 25-28, 29-32, 33-36, 37-40, 41-44, and 45-48. The SFP28/SFP+ port speed should be the same (10 Gbps or 25 Gbps) across all ports in the 4-port group.
Switching method Cut-through.
Data traffic types Unicast, multicast, broadcast.
Software features Enterprise Fabric Operating System (EFOS):
Layer 2 switching, Layer 3 switching, virtual local area networks (VLANs), VLAN tagging, spanning tree protocol (STP), link aggregation (trunk) groups (LAGs), Virtual Port Channels (VPCs), link dependency, quality of service (QoS), IPv4/IPv6 management, IPv4 routing (OSPF v2, BGP v4), IPv6 routing (OSPF v3), equal cost multiple paths (ECMP), IPv4/IPv6 virtual router redundancy protocol (VRRP), IPv4/IPv6 policy-based routing (PBR), IPv4 Internet Group Management Protocol (IGMP) v2/v3, IPv6 Multicast Listener Discovery (MLD), IPv4/IPv6 protocol independent multicast (PIM), Virtual Routing and Forwarding (VRF) Lite, Data Center Virtual Private Network (DCVPN) Gateway, OpenFlow 1.0 and 1.3, Converged Enhanced Ethernet (CEE).
Performance Non-blocking architecture with wire-speed forwarding of traffic:
  • 100% line-rate performance
  • Up to 4 Tbps aggregated throughput
  • Up to 1000 Million packets per second (Mpps)
  • Up to 12 288-byte jumbo frames
  • Buffer size: 32 MB
Cooling Six N+2 redundant hot-swap fans. Rear (non-port side) to front (port side)  airflow.
Power supplies Two load-sharing, redundant hot-swap 750 W AC (100 - 240 V) power supplies (each power supply has an IEC 320-C14 connector).
Hot-swap parts SFP28/SFP+/QSFP28/QSFP+ transceivers and DAC cables; power supplies; system fans.
Management ports 1x 10/100/1000 Mb Ethernet port (RJ-45); 1x RS-232 port (RJ-45); 1x USB 2.0 port (for mass storage devices).
Management interfaces Industry standard command line interface (isCLI); SNMP v1, V2, and v3; NETCONF (XML); RESTCONF (HTTP); AutoInstall; Zero Touch Provisioning (ZTP); RESTful API.
Security features Secure Shell (SSH); Secure Copy (SCP); Secure FTP (sFTP); user level security; RADIUS and TACACS+ authentication; access control lists (ACLs), port security; port-based network access control (IEEE 802.1x).
Warranty and support One-year base warranty with 9x5 coverage and next business day parts delivered. Optional warranty service upgrades are available: 9x5 coverage with NBD onsite response (Foundation Service), 24x7 coverage with 4-hour onsite response (Essential Service). Software entitlement is included in the base warranty and warranty service upgrades for the duration of the warranty period.
Note: Warranty service is provided by Broadcom and Tech Data.
Dimensions Height: 43 mm (1.7 in.); width: 440 mm (17.3 in.); depth: 508 mm (20.0 in.).
Weight  9.7 kg (21.4 lb).

Models

Factory-integrated models of the BES-53248 are configured by using the Lenovo Data Center Solution Configurator (DCSC): http://dcsc.lenovo.com

The factory-integrated models of the switch and their components and options, which are all described in this product guide, use the Configure-to-Order (CTO) base model that is listed in the following table.

Only for storage clustering: The BES-53248 is offered by Lenovo only for ThinkSystem DM or ThinkSystem DG MetroCluster and scale-out cluster functionality.

Table 2. CTO base model
Description Machine Type/Model
BES-53248 Ethernet Storage Switch: 16x SFP ports and 2x QSFP ports active, 2 PS 7D2SCTO1WW

The following table lists the system unit bases for the BES-53248 Ethernet Storage Switches for Lenovo.

Table 3. System unit bases
Description Feature code
BES-53248 Ethernet Storage Switch: 16x SFP and 2x QSFP Ports Active, 2 PS (North America) BB4R
BES-53248 Ethernet Storage Switch: 16x SFP and 2x QSFP Ports Active, 2 PS B7KP

The packaging for the BES-53248 Ethernet Storage Switch for Lenovo models include the following items:

  • One switch unit with two power supplies and six system fans.
  • Two customer-selected power cables.
  • RJ-45 to DB-9 serial console cable.
  • Statement paper.

Configuration notes:

  • Power cables are not included and must be ordered together with the switch (see Power supplies and cables for details).
  • Transceivers and cables are not included and should be ordered for the switch (see Transceivers and cables for details).
  • The switch must be ordered together with the tool-less slide rail kit (see Rack installation).

Port activation licenses

The BES-53248 Ethernet Storage Switch for Lenovo ships with 16x SFP and 2x QSFP licensed ports active (transceivers are not included). The remaining 32x SFP and 6x QSFP unlicensed ports can be activated by purchasing and installing the Ports on Demand (POD) licenses.

The following table lists the POD licenses for the BES-53248 Ethernet Storage Switch for Lenovo. You can use a combination of these part numbers to activate the ports you want to use. For example, consider the following scenarios:   

  • To activate all ports, purchase three 7S0C001HWW, plus one 7S0C001NWW license.
  • To activate the SFP ports purchase 1-4 7S0C001NWW licenses.
  • To activate the QSFP ports purchase a single 7S0C001MWW license.
Table 4. POD license option
Description Part number Feature code Maximum quantity
BES-53248 SW License: 8x SFP ports (no transceivers) 7S0C001NWW S5EJ 4*
BES-53248 SW License: 8x SFP and 2x QSFP ports (no transceivers) ** 7S0C001HWW S2QR
BES-53248 SW License: 6x QSFP ports (no transceivers)*** 7S0C001MWW S5EH 1

Configuration note: 

* Support a total of four of any mix of these licenses.

** For the first three POD licenses applied to the switch, each POD license activates 8x SFP and 2x QSFP ports. The fourth POD license applied to the switch activates the remaining 8x SFP ports.

*** A max of 6 additional QSFP+ ports can be activated when buying this license consider only pairing with the 7S0C001NWW.

Transceivers and cables

With the flexibility of the BES-53248 Ethernet Storage Switch for Lenovo, customers can choose the following connectivity technologies:

  • For 10 GbE links, customers can use SFP ports with 10 GbE SFP+ direct-attached copper (DAC) cables for distances up to 5 meters. For longer distances, the 10GBASE-SR SFP+ transceivers can be used for up to 300 meters on OM3 or up to 400 meters on OM4 MMF cables, and the 10GBASE-LR SFP+ transceivers can support distances up to 10 kilometers on SMF cables.

  • For 25 GbE links, customers can use SFP ports with 25 GbE SFP28 DAC cables for distances up to 5 meters. For longer distances, the 25GBASE-SR SFP28 transceivers can be used for up to 70 meters on OM3 or up to 100 meters on OM4 MMF cables.

  • For 40 GbE links, customers can use QSFP ports with QSFP+ to QSFP+ DAC cables for distances up to 5 meters. For longer distances, customers can use the 40GBASE-eSR4 QSFP+ transceivers for distances up to 300 meters on OM3 or up to 400 meters on OM4 MMF cables.

  • For 100 GbE links, customers can use QSFP ports with QSFP28 DAC cables for distances up to 5 meters. For longer distances, the 100GBASE-SR4 QSFP28 transceivers can be used for distances up to 70 meters on OM3 or up to 100 meters on OM4 MMF cables.

Note: SFP ports are combined into 12 consecutive 4-port groups: Ports 1-4, 5-8, 9-12, 13-16, 17-20, 21-24, 25-28, 29-32, 33-36, 37-40, 41-44, and 45-48. The SFP port speed should be the same (10 Gbps or 25 Gbps) across all ports in the 4-port group.

The following tables list the supported cables and transceivers:

Table 5. Optical transceivers and cables
Part number Feature code Description Maximum
quantity
Optical transceivers
46C3447 5053 Lenovo 10Gb SFP+ SR Transceiver (10GBASE-SR) 48
00FE331 B0RJ Lenovo 10Gb SFP+ LR Transceiver (10GBASE-LR) 48
4XF7A39597 B732 25Gb Ethernet Optical SFP28 Shortwave Module 1 Pack 48
4M27A67041 BFH2 Lenovo 25Gb SR SFP28 Ethernet Transceiver 48
00FE325 A5U9 Lenovo 40GBASE-eSR4 QSFP+ Transceiver 8
4XF7A39598 B733 100Gb Ethernet Optical QSFP28 Shortwave Module 1 Pack 8
4M27A67042 BFH1 Lenovo 100Gb SR4 QSFP28 Ethernet Transceiver 8
OM3 optical cables for 10 GbE SR SFP+ and 25 GbE SR SFP28 optical transceivers
00MN499 ASR5 Lenovo 0.5m LC-LC OM3 MMF Cable 48
00MN502 ASR6 Lenovo 1m LC-LC OM3 MMF Cable 48
00MN505 ASR7 Lenovo 3m LC-LC OM3 MMF Cable 48
00MN508 ASR8 Lenovo 5m LC-LC OM3 MMF Cable 48
00MN511 ASR9 Lenovo 10m LC-LC OM3 MMF Cable 48
00MN514 ASRA Lenovo 15m LC-LC OM3 MMF Cable 48
00MN517 ASRB Lenovo 25m LC-LC OM3 MMF Cable 48
00MN520 ASRC Lenovo 30m LC-LC OM3 MMF Cable 48
OM4 optical cables for 10 GbE SR SFP+ and 25 GbE SR SFP28 optical transceivers
4Z57A10845 B2P9 Lenovo 0.5m LC-LC OM4 MMF Cable 48
4Z57A10846 B2PA Lenovo 1m LC-LC OM4 MMF Cable 48
4Z57A10847 B2PB Lenovo 3m LC-LC OM4 MMF Cable 48
4Z57A10848 B2PC Lenovo 5m LC-LC OM4 MMF Cable 48
4Z57A10849 B2PD Lenovo 10m LC-LC OM4 MMF Cable 48
4Z57A10850 B2PE Lenovo 15m LC-LC OM4 MMF Cable 48
4Z57A10851 B2PF Lenovo 25m LC-LC OM4 MMF Cable 48
4Z57A10852 B2PG Lenovo 30m LC-LC OM4 MMF Cable 48
OM4 optical cables for 40 GbE QSFP+ and 100 GbE QSFP28 SR4 transceivers
7Z57A03567 AV25 Lenovo 5m MPO-MPO OM4 MMF Cable 8
7Z57A03568 AV26 Lenovo 7m MPO-MPO OM4 MMF Cable 8
7Z57A03569 AV27 Lenovo 10m MPO-MPO OM4 MMF Cable 8
7Z57A03570 AV28 Lenovo 15m MPO-MPO OM4 MMF Cable 8
7Z57A03571 AV29 Lenovo 20m MPO-MPO OM4 MMF Cable 8
7Z57A03572 AV2A Lenovo 30m MPO-MPO OM4 MMF Cable 8
Table 6. DAC cables
Part number Feature code Description Maximum
quantity
SFP+ passive direct-attach copper cables - 10 GbE
00D6288 A3RG Lenovo 0.5m Passive SFP+ DAC Cable 48
90Y9427 A1PH Lenovo 1m Passive SFP+ DAC Cable 48
00AY764 A51N Lenovo 1.5m Passive SFP+ DAC Cable 48
00AY765 A51P Lenovo 2m Passive SFP+ DAC Cable 48
90Y9430 A1PJ Lenovo 3m Passive SFP+ DAC Cable 48
90Y9433 A1PK Lenovo 5m Passive SFP+ DAC Cable 48
SFP28 passive direct-attach copper cables - 25 GbE
7Z57A03557 AV1W Lenovo 1m Passive 25G SFP28 DAC Cable 48
7Z57A03558 AV1X Lenovo 3m Passive 25G SFP28 DAC Cable 48
7Z57A03559 AV1Y Lenovo 5m Passive 25G SFP28 DAC Cable 48
QSFP+ passive direct-attach copper cables - 40 GbE
49Y7890 A1DP Lenovo 1m Passive QSFP+ DAC Cable 8
49Y7891 A1DQ Lenovo 3m Passive QSFP+ DAC Cable 8
00D5810 A2X8 Lenovo 5m Passive QSFP+ DAC Cable 8
QSFP28 direct attach copper cables - 100 GbE
7Z57A03561 AV1Z Lenovo 1m Passive 100G QSFP28 DAC Cable 8
7Z57A03562 AV20 Lenovo 3m Passive 100G QSFP28 DAC Cable 8
7Z57A03563 AV21 Lenovo 5m Passive 100G QSFP28 DAC Cable 8
Table 7. UTP cables for 1 GbE management port
Part number Feature code Description Maximum
quantity
40K5679 3801 0.6m Blue Cat5e Cable 1
40K8785 3802 1.5m Blue Cat5e Cable 1
40K5581 3803 3m Blue Cat5e Cable 1
40K8927 3804 10m Blue Cat5e Cable 1
40K8930 3805 25m Blue Cat5e Cable 1

The network cables that can be used with the switch are listed in the following table.

Table 8. BES-53248 Ethernet Storage Switch for Lenovo network cabling requirements
Transceiver Standard Cable Connector
10 Gb Ethernet
10Gb SR SFP+ (46C3447) 10GBASE-SR Up to 30 m with fiber optic cables supplied by Lenovo (see Table 5); up to 300 m with OM3 or up to 400 m with OM4 multimode fiber optic cables. LC
10Gb LR SFP+ (00FE331) 10GBASE-LR 1310 nm single-mode fiber optic cable up to 10 km. LC
Direct attach copper cable 10GSFP+Cu SFP+ to SFP+ DAC cables up to 5 m (see Table 6). SFP+
25 Gb Ethernet
25Gb SR SFP28
(4XF7A39597)
25GBASE-SR Up to 30 m with fiber optic cables supplied by Lenovo (see Table 5); up to 70 m with OM3 or up to 100 m with OM4 multimode fiber optic cables. LC
Direct attach copper cable 25GBASE-CR SFP28 DAC cables up to 5 m (see Table 6). SFP28
40 Gb Ethernet
40Gb eSR4 QSFP+ (00FE325) 40GBASE-SR4 Up to 30 m with MPO-MPO fiber optic cables supplied by Lenovo (see Table 5); up to 300 m with OM3 or up to 400 m with OM4 multimode fiber optic cables. MPO
Direct attach copper cable 40GBASE-CR4 QSFP+ to QSFP+ DAC cables up to 5 m (see Table 6). QSFP+
100 Gb Ethernet
100Gb SR4 QSFP28
(4XF7A39598)
100GBASE-SR4 Up to 30 m with MPO-MPO fiber optic cables supplied by Lenovo (see Table 5); up to 70 m with OM3 or up to 100 m with OM4 multimode fiber optic cables. MPO
Direct attach copper cable 100GBASE-CR4 QSFP28 to QSFP28 DAC cables up to 5 m (see Table 6). QSFP28
Management ports
1 GbE port 1000BASE-T Up to 25 m with UTP Category 5E cables supplied by Lenovo (see Table 7); UTP Category 5, 5E, or 6 cables up to 100 m. RJ-45
RJ-45 serial port RS-232 DB-9 to RJ-45 cable (comes with the switch). RJ-45

Software

The BES-53248 Ethernet Storage Switch for Lenovo with offers the following software features  (more information can be found in documentation at on the BES-Switch Global Support: http://www.broadcom.com/support/bes-switch):

  • Scalability and performance:
    • Media access control (MAC) address learning with automatic updates
    • Static and 802.3ad Link Aggregation Control Protocol (LACP) link aggregation groups (LAGs)
    • Configurable load balancing over LAGs (source or destination MAC, VLAN, or IP)
    • Broadcast, multicast, and unicast storm recovery
    • IPv4 IGMP/IPv6 MLD snooping and querier to limit flooding of IP multicast traffic
  • Availability and redundancy:
    • 802.1D Spanning Tree Protocol (STP) for providing Layer 2 (L2) redundancy
    • 802.1s Multiple STP (MSTP) for topology optimization
    • 802.1w Rapid STP (RSTP) for rapid convergence for delay-sensitive traffic, such as voice
    • Per-VLAN STP (PVSTP) and Rapid PVST (RPVSTP) enhancements
    • Unidirectional Link Detection (UDLD) protocol
    • Link dependency to support active/standby NIC configurations on the connected nodes
    • L2 Loop Protection to detect loops in downstream switches that do not run STP
    • Forward Error Correction (FEC) on ports operating at 25 Gbps and 100 Gbps speeds
  • Virtual Local Area Networks (VLANs):
    • Up to 4094 VLANs
    • Port-based, MAC-based, and protocol-based VLANs
    • 802.1Q VLANs and VLAN tagging on all ports
    • 802.1Q-in-Q VLAN tunneling (Double VLAN [DVLAN])
    • Private VLANs
    • Multicast VLAN Registration (MVR)
  • Security:
    • MAC-, IPv4-, and IPv6-based access control lists (ACLs)
    • Management access control and administration list (MACAL)
    • 802.1x port-based network access control
    • Protected ports
    • Port security
    • Multiple user IDs and passwords
    • Privilege-based user access control
    • Authentication and authorization through local user database, RADIUS, or TACACS+
    • Protection from Denial of Service (DoS) attacks
    • DHCP snooping (IPv4/IPv6)
    • IP Source Guard (IPv4/IPv6)
  • Quality of Service (QoS):
    • IEEE 802.1p, IP ToS/DSCP, DiffServ, and ACL-based traffic classification and processing
    • Multiple Class of Service (COS) queues per port for processing qualified traffic
    • Tail dropping, Weighted Random Early Discard (WRED), or strict priority queue scheduling
    • Traffic shaping and re-marking based on defined policies
    • IPv4/IPv6 ACL metering
  • IP v4 Layer 3 functions:
    • Host management
    • Routed ports (Switch ports as Layer 3 interfaces)
    • Address Resolution Protocol (ARP) and Proxy ARP
    • IP forwarding
    • IP filtering with ACLs
    • Static routes
    • Dynamic routing protocols:
      • Routing Information Protocol (RIP) v1/v2
      • Open Shortest Path First (OSPF) v2
      • Border Gateway Protocol (BGP) v4
      • Distance Vector Multicast Routing Protocol (DVMRP)
    • Equal Cost Multiple Paths (ECMP)
    • Virtual Router Redundancy Protocol (VRRP) v3
    • Policy-based routing (PBR)
    • Dynamic Host Configuration Protocol (DHCP) server, client, and relay operations
    • Internet Group Management Protocol (IGMP) v2/v3
    • Protocol Independent Multicast (PIM) in Sparse Mode (PIM-SM) and Dense Mode (PIM-DM)
    • Domain Name System (DNS) client
  • IPv6 Layer 3 functions:
    • IPv6 host management
    • Routed ports (Switch ports as Layer 3 interfaces)
    • Neighbor Discovery
    • IPv6 forwarding
    • IPv6 filtering with ACLs
    • Static routes
    • Dynamic routing protocol: OSPF v3
    • ECMP
    • VRRP v3
    • PBR
    • DHCP server, client, and relay operations
    • Multicast Listener Discovery (MLD)
    • PIM-SM and PIM-DM
    • DNS client
  • Virtualization:
    • Virtual Port Channels (VPCs): Two peer switches form a single virtual entity for link aggregation (MLAG)
    • Virtual Routing and Forwarding (VRF) Lite: Multiple routing domains on the same switch
    • Data Center Virtual Private Network (DCVPN) Gateway: VXLAN/NVGRE communications with another network
    • Software Defined Networking (SDN): OpenFlow 1.0 and 1.3
  • Converged Enhanced Ethernet:
    • Priority-Based Flow Control (PFC): Pausing traffic based on priority to eliminate frame loss due to congestion on a link
    • Enhanced Transmission Selection (ETS): Allocating link bandwidth based on priority
    • Congestion Notification (CN): Congestion management for loss- or latency-sensitive network data flows
    • Data Center Bridging Capability Exchange Protocol (DCBX): Exchanging configuration information with directly connected peers
  • Monitoring:
    • Switch LEDs for port status and switch status indication
    • Port mirroring (Switched Port Analyzer [SPAN] / Remote SPAN [RSPAN] / Encapsulated RSPAN [ERSPAN])
    • Remote Monitoring (RMON) agent to collect statistics and monitor switch performance
    • Buffered log, console log, and syslog for change tracking and logging
    • Email alerts
    • sFlow agent for monitoring traffic in data networks (an sFlow analyzer required elsewhere)
  • Manageability:
    • Command line interface (CLI)
      • Serial interface
      • Telnet
      • Secure Shell (SSH) v2
    • Scriptable CLI
    • Simple Network Management Protocol (SNMP V1, V2, and V3)
    • NETCONF (XML)
    • RESTCONF (HTTP)
    • AutoInstall and Zero Touch Provisioning (ZTP) for automated switch software image upgrade and configuration
    • HTTP, HTTPS, TFTP, FTP, Secure FTP (sFTP), and Secure Copy (SCP) file transfer protocols
    • Industry Standard Discovery Protocol (ISDP) for discovering Cisco devices running CDP
    • Link Layer Discovery Protocol (LLDP) for discovering network devices
    • Dual firmware images
    • Simple Network Time Protocol (SNTP) and Precision Time Protocol (PTP) for switch clock synchronization
    • RESTful API

Ethernet standards

The BES-53248 Ethernet Storage Switch for Lenovo supports the following IEEE Ethernet standards:

  • IEEE 802.1Q VLANs
  • IEEE 802.3ac VLAN Tagging
  • IEEE 802.1v Protocol-based VLANs
  • IEEE 802.1D Spanning Tree Protocol (STP)
  • IEEE 802.1s Multiple STP (MSTP)
  • IEEE 802.1w Rapid STP (RSTP)
  • IEEE 802.3ad Link Aggregation Control Protocol
  • IEEE 802.1p Class of Service (CoS) prioritization
  • IEEE 802.3x Full-duplex Flow Control
  • IEEE 802.1Qau Congestion Notification (CN)
  • IEEE 802.1Qaz Enhanced Transmission Selection (ETS)
  • IEEE 802.1Qbb Priority-Based Flow Control (PFC)
  • IEEE 802.3bj-CL91: Forward Error Correction (FEC)
  • IEEE 802.1AB Link Layer Discovery Protocol (LLDP)
  • IEEE 802.1AB Data Center Bridging Capability Exchange Protocol (DCBX) (LLDP extension)
  • IEEE 802.3ae 10GBASE-SR short range fiber optics 10 Gb Ethernet
  • IEEE 802.3ae 10GBASE-LR long range fiber optics 10 Gb Ethernet
  • IEEE 802.3by 25GBASE-CR copper 25 Gb Ethernet
  • IEEE 802.3by 25GBASE-SR short range fiber optics 25 Gb Ethernet
  • IEEE 802.3ba 40GBASE-CR4 copper 40 Gb Ethernet
  • IEEE 802.3ba 40GBASE-SR4 short range fiber optics 40 Gb Ethernet
  • IEEE 802.3bj 100GBASE-CR4 copper 100 Gb Ethernet
  • IEEE 802.3bm 100GBASE-SR4 short range fiber optics 100 Gb Ethernet
  • IEEE 802.3 10BASE-T Ethernet (Ethernet management port only)
  • IEEE 802.3u 100BASE-TX Fast Ethernet (Ethernet management port only)
  • IEEE 802.3ab 1000BASE-T copper twisted pair Gigabit Ethernet (Ethernet management port only)

Cooling

The BES-53248 Ethernet Storage Switch for Lenovo provides rear-to-front airflow with six variable-speed, hot-swap system fans with N+2 cooling redundancy.

Power supplies and cables

The BES-53248 Ethernet Storage Switch for Lenovo ships with two load-sharing, redundant hot-swap 750 W AC power supplies.

The BES-53248 Ethernet Storage Switch for Lenovo ships with two customer-selected power cables. The following table lists power cables that are available for selection (two power cables are required per switch).

Table 9. Power cable options
Part number Feature code Description
Rack power cables
00Y3043 A4VP 1.0m, 10A/100-250V, C13 to C14 Jumper Cord
4L67A08367 B0N5 1.0m, 13A/100-250V, C13 to C14 Jumper Cord
47C2491 A3SW 1.2m, 16A/100-250V, 2 Short C13s to Short C20 Rack Power Cable
39Y7937 6201 1.5m, 10A/100-250V, C13 to C14 Jumper Cord
4L67A08368 B0N6 1.5m, 13A/100-250V, C13 to C14 Jumper Cord
4L67A08365 B0N4 2.0m, 10A/100-250V, C13 to C14 Jumper Cord
4L67A08369 6570 2.0m, 13A/100-250V, C13 to C14 Jumper Cord
47C2492 A3SX 2.5m, 16A/100-250V, 2 Long C13s to Short C20 Rack Power Cable
4L67A08366 6311 2.8m, 10A/100-250V, C13 to C14 Jumper Cord
4L67A08370 6400 2.8m, 13A/100-250V, C13 to C14 Jumper Cord
39Y7938 6204 2.8m, 10A/100-250V, C13 to IEC 320-C20 Rack Power Cable
47C2493 A3SY 2.8m, 16A/100-250V, 2 Short C13s to Long C20 Rack Power Cable
47C2494 A3SZ 4.1m, 16A/100-250V, 2 Long C13s to Long C20 Rack Power Cable
39Y7932 6263 4.3m, 10A/100-250V, C13 to C14 Jumper Cord
4L67A08371 6583 4.3m, 13A/100-250V, C13 to C14 Rack Power Cable
Line cords
39Y7924 6211 2.8m, 10A/250V, C13 to AS/NZ 3112 (Australia/NZ) Line Cord
39Y7923 6215 2.8m, 10A/250V, C13 to BS 1363/A (UK) Line Cord
39Y7917 6212 2.8m, 10A/230V, C13 to CEE7-VII (Europe) Line Cord
39Y7921 6217 2.8m, 220-240V, C13 to CEI 23-16 (Italy/Chile) Line Cord
81Y2375 6317 2.8m, 10A/240V, C13 to CNS 10917-3 (Taiwan) Line Cord
39Y7918 6213 2.8m, 10A/250V, C13 to DK2-5a (Denmark) Line Cord
39Y7928 6210 2.8m, 10A/220V, C13 to GB 2099.1 (China) Line Cord
39Y7930 6222 2.8m, 10A/250V, C13 to IRAM 2073 (Argentina) Line Cord
39Y7927 6269 2.8m, 10A/250V, C13(2P+Gnd) (India) Line Cord
69Y1988 6532 2.8m, 10A/250V, C13 to NBR 14136 (Brazil) Line Cord
46M2592 A1RF 2.8m, 10A/250V, C13 to NEMA 6-15P Line Cord
39Y7922 6214 2.8m, 10A/250V, C13 to SABS 164 (S Africa) Line Cord
39Y7919 6216 2.8m, 10A/250V, C13 to SEV 1011-S24507 (Swiss) Line Cord
39Y7920 6218 2.8m, 10A/250V, C13 to SI 32 (Israel) Line Cord
46M2593 A1RE 2.8m, 12A/125V, C13 to JIS C-8303 (Japan) Line Cord
4L67A08357 6533 2.8m, 12A/200V, C13 to JIS C-8303 (Japan) Line Cord
39Y7925 6219 2.8m, 220-240V, C13 to KETI (S Korea) Line Cord
90Y3016 6313 2.8m, 10A/120V, C13 to NEMA 5-15P (US) Line Cord
00WH545 6401 2.8m, 13A/120V, C13 to NEMA 5-15P (US) Line Cord
81Y2374 6402 2.8m, 13A/125V, C13 to CNS 60799 (Taiwan) Line Cord
81Y2383 6574 4.3m, 10A/230V, C13 to AS/NZS 3112 (Aus/NZ) Line Cord
81Y2377 6577 4.3m, 10A/230V, C13 to BS 1363/A (UK) Line Cord
81Y2376 6572 4.3m, 10A/230V, C13 to CEE7-VII (Europe) Line Cord
81Y2380 6493 4.3m, 10A/230V, C13 to CEI 23-16 (Italy/Chile) Line Cord
81Y2389 6531 4.3m, 10A/250V, C13 to 76 CNS 10917-3 (Taiwan) Line Cord
81Y2382 6575 4.3m, 10A/230V, C13 to DK2-5a (Denmark) Line Cord
81Y2378 6580 4.3m, 10A/220V, C13 to GB 2099.1 (China) Line Cord
81Y2384 6492 4.3m 10A/220V, C13 to IRAM 2073 (Argentina) Line Cord
81Y2386 6567 4.3m, 10A/240V, C13 to IS 6538 (India) Line Cord
81Y2387 6404 4.3m, 10A/250V, C13 - 2P+Gnd (Brazil) Line Cord
4L67A08361 6373 4.3m, 10A/250V, C13 to NEMA 6-15P (US) Line Cord
81Y2379 6576 4.3m, 10A/230V, C13 to SABS 164 (South Africa) Line Cord
81Y2390 6578 4.3m, 10A/230V, C13 to SEV 1011-S24507 (Sws) Line Cord
81Y2381 6579 4.3m, 10A/230V, C13 to SI 32 (Israel) Line Cord
39Y7926 6335 4.3m, 12A/100V, C13 to JIS C-8303 (Japan) Line Cord
4L67A08362 6495 4.3m, 12A/200V, C13 to JIS C-8303 (Japan) Line Cord
81Y2385 6494 4.3m, 12A/220V, C13 to KSC 8305 (S. Korea) Line Cord
4L67A08359 6370 4.3m, 10A/125V, C13 to NEMA 5-15P (US) Line Cord
4L67A08360 AX8A 4.3m, 13A/120V, C13 to NEMA 5-15P (US) Line Cord
81Y2388 6530 4.3m, 13A/125V, C13 to CNS 10917 (Taiwan) Line Cord

Rack installation

The BES-53248 Ethernet Storage Switch for Lenovo must be ordered together the tool-less slide rail kit. The tool-less slide rail kit is used for installing the switch in a 4-post, IEC standard-compliant rack cabinet with square or round mounting holes and distance between front and rear mounting flanges from 685.8 mm (27 in.) to 812.8 mm (32 in.).

The following table lists the tool-less slide rail kit.

Table 10. Tool-less slide rail kit
Description Part number Feature code Quantity
BES Standard 4-post 19" Rack Mount Rail Kit 4M17A60883 None* 1

* Field upgrade only; ships in a separate box.

Configuration note:  The switch must be ordered together with the BES Standard 4-post 19" Rack Mount Rail Kit.

Physical specifications

The BES-53248 Ethernet Storage Switch for Lenovo has the following dimensions and weight (approximate):

  • Height: 43 mm (1.7 in.)
  • Width: 440 mm (17.3 in.)
  • Depth: 508 mm (20.0 in.)
  • Weight (maximum): 9.7 kg (21.4 lb)

Operating environment

The BES-53248 Ethernet Storage Switch for Lenovo is supported in the following operating environment:

  • Temperature: 0 - 45 ºC (32 - 113 ºF).
  • Relative humidity: 10 - 90% (Non-condensing)
  • Altitude: Up to 900 m (2,952 feet)
  • Acoustic noise: Less than 70 dB
  • Electrical input:
    • 100 - 240 V AC auto-switching, 50 / 60 Hz
    • 3.3 A max (100 V AC), 1.65 A max (200 V AC)
  • Power consumption
    • Typical: 229 W
    • Maximum: 330 W
  • Heat dissipation
    • Typical: 782 BTU/hour
    • Maximum: 1127 BTU/hour

Warranty and support

The warranty service for the BES-53248 Ethernet Storage Switch for Lenovo is provided by Broadcom and Tech Data. Customers should submit service tickets for switch-related issues through the support portal or by calling one of the dedicated numbers found here:
http://servicesbytechdata.force.com/BESSwitch/s/login/

In the environments with the BES-53248 Ethernet Storage Switches for Lenovo and Lenovo ThinkSystem DM Series, customers may submit service tickets to Lenovo. Lenovo will perform problem determination and resolution for DM Series-related issues and escalate to Tech Data, on behalf of the customer, for switch-related problem determination. Broadcom or Tech Data will contact the customer and will own the switch-related problem resolution until closure.

The BES-53248 Ethernet Storage Switch for Lenovo comes with a 1-year base warranty with 9x5 Next Business Day (NBD) parts delivered and includes entitlement to code fixes and updates over that period. Also available are warranty service upgrades, with a well-defined scope of services, including service hours, response time, term of service, and service agreement terms and conditions.

The following warranty service upgrades are available for the BES-53248 Ethernet Storage Switch for Lenovo:

  • 3 or 5 years of warranty service coverage
  • 9x5 service coverage with next business day onsite response
  • 24x7 service coverage with 4-hour onsite response

Notes:

  • The options installed in the switch assume the switch’s base warranty and any warranty service upgrade for the switch. Any cable- or transceiver-specific issues will be transferred to Lenovo for resolution.
  • Warranty service upgrades include entitlement to code fixes and updates over the duration of the selected service coverage period.

The following table lists warranty service upgrades that are available for the BES-53248 Ethernet Storage Switch for Lenovo.

Table 11. Warranty service upgrades
Description Part number Feature code
BES-53248 Foundation Service - 3Yr 9X5 Next Business Day Response 7S0C001DWW S2CN
BES-53248 Foundation Service - 5Yr 9X5 Next Business Day Response 7S0C001EWW S2CP
BES-53248 Essential Service - 3Yr 24x7x365 4Hr Response 7S0C001FWW S2CQ
BES-53248 Essential Service - 5Yr 24x7x365 4Hr Response 7S0C001GWW S2CR

Lenovo warranty service upgrade offerings are region-specific. Not all warranty service upgrades are available in every region. For information about Lenovo warranty service upgrade offerings that are available in your region, refer to the following resource:

Contact a local Lenovo representative for details on region-specific support and details on response times.

Some regions might have different warranty terms and conditions than the standard warranty. Local Lenovo sales representatives can assist in explaining region-specific terms when needed. Examples of region-specific warranty terms are second or longer business day parts delivery or parts-only warranty.

If warranty terms and conditions include onsite labor for repair or replacement of parts, a service technician is dispatched to the customer site to perform the replacement.

If warranty terms include parts-only warranty, only replacement parts that are under warranty will be sent to a requested location for self-service. Parts-only service does not include a service technician being dispatched onsite. Parts must be changed at customer’s own cost and labor and defective parts must be returned following the instructions supplied with the spare parts.

For service definitions, region-specific details, and service limitations, please refer to the following resources:

Note: These resources might contain additional SLA options that are not offered by Lenovo. Please contact a local Lenovo sales representative in your region for any specific questions.

Regulatory compliance

The BES-53248 Ethernet Storage Switch for Lenovo conforms to the following regulations:

  • Safety:
    • UL
    • cUL
    • CB
    • CCC
    • BSMI
  • Electromagnetic compatibility (EMC):
    • FCC
    • CE
    • VCCI
    • CCC
    • BSMI
  • Environmental: Reduction of Hazardous Substances (ROHS) 6

Storage connectivity

The external storage systems that are currently offered by Lenovo that can be used with the BES-53248 Ethernet Storage Switches for Lenovo for storage clustering and MetroCluster IP configurations are as follows:

  • ThinkSystem DM Series
  • ThinkSystem DG Series

Only for storage clustering: The BES-53248 is offered by Lenovo only for ThinkSystem DM or ThinkSystem DG MetroCluster and scale-out cluster functionality.

For more information, see the Product Guides for the DM and DG storage systems:

Related product families

Product families related to this document are the following:

Trademarks

Lenovo and the Lenovo logo are trademarks or registered trademarks of Lenovo in the United States, other countries, or both. A current list of Lenovo trademarks is available on the Web at https://www.lenovo.com/us/en/legal/copytrade/.

The following terms are trademarks of Lenovo in the United States, other countries, or both:
Lenovo®
ThinkSystem®

Other company, product, or service names may be trademarks or service marks of others.