Abstract

The Lenovo ThinkSystem Emulex® Secure Fibre Channel (FC) host bus adapters (HBAs) by Broadcom are designed to deliver the highest level of security, performance, and manageability for mission-critical infrastructures.

This product guide describes the Emulex FC HBAs and provides essential pre-sales information to understand the products, their key features and specifications, and compatibility. This guide is intended for technical specialists, sales specialists, sales engineers, and IT architects who want to learn more about the adapters and consider their use in IT solutions.

Introduction

The Lenovo ThinkSystem Emulex® Secure Fibre Channel host bus adapters (FC HBAs) by Broadcom are designed to deliver the highest level of security, performance, and manageability for mission-critical infrastructures.

Cybersecurity is a focal point of enterprises and governments globally. The longstanding approach of protecting critical data via firewalls is no longer sufficient, and the combination of artificial intelligence (AI) and quantum computing magnifies the risk if data is not encrypted at all points in the data center including the network. Emulex Secure HBAs integrate the most robust quantum-resistant algorithms to ensure that encrypted data remains encrypted even as quantum computing and AI put legacy encryption at risk.

ThinkSystem Emulex LPe38102 64Gb 2-Port PCIe Fibre Channel Adapter
Figure 1. ThinkSystem Emulex LPe38102 64Gb 2-Port PCIe Fibre Channel Adapter

Did you know?

Emulex makes it easy to deploy, manage and upgrade SANs with no server reboots needed for firmware updates, queue depth changes, or optics replacements. The adapters implement the industry-standard INCITS/T11 specification, which includes full Fabric Performance Impact Notification (FPIN) and signaling support to collaborate with the fabric to identify and address performance problems.

Part number information

The following table lists the ordering information for the adapters.

Table 1. Part number information
Part number Feature code Description
4XC7A96457 C5FC ThinkSystem Emulex LPe37102 32Gb 2-Port PCIe Fibre Channel Adapter
4XC7A96458 C5FD ThinkSystem Emulex LPe38102 64Gb 2-Port PCIe Fibre Channel Adapter

The part number includes the following items:

  • One adapter with two FC SW SFP+ optical transceivers installed
    • LPe37102 includes 2x 32Gb transceivers (32/16/8 Gbps speeds)
    • LPe38102 includes 2x 64Gb transceivers (64/32/16 Gbps speeds)
  • 3U (full-height) bracket attached and 2U (low-profile) bracket included in the box
  • Publications flyer

The following figure shows the ThinkSystem Emulex LPe37102 32Gb 2-Port PCIe Fibre Channel Adapter.

ThinkSystem Emulex LPe37102 32Gb 2-Port PCIe Fibre Channel Adapter
Figure 2. ThinkSystem Emulex LPe37102 32Gb 2-Port PCIe Fibre Channel Adapter

Fiber optic cables

The transceivers support the following Multi-Mode Fiber (MMF) cable lengths:

Note: A minimum cable length of 0.5m is required.

  • Operating at 64 Gbps:
    • Up to 70 m on 50/125 µm OM3 MMF
    • Up to 100 m on 50/125 µm OM4 MMF
    • Up to 100 m on 50/125 µm OM5 MMF
  • Operating at 32 Gbps:
    • Up to 20 m on 50/125 µm OM2 MMF
    • Up to 70 m on 50/125 µm OM3 MMF
    • Up to 100 m on 50/125 µm OM4 MMF
    • Up to 100 m on 50/125 µm OM5 MMF

The following table lists the supported optical cables.

Table 2. Optical cables
Part numberFeature codeDescription
LC-LC OM3 Fiber Optic Cables
00MN499ASR5Lenovo 0.5m LC-LC OM3 MMF Cable
00MN502ASR6Lenovo 1m LC-LC OM3 MMF Cable
00MN505ASR7Lenovo 3m LC-LC OM3 MMF Cable
00MN508ASR8Lenovo 5m LC-LC OM3 MMF Cable
00MN511ASR9Lenovo 10m LC-LC OM3 MMF Cable
00MN514ASRALenovo 15m LC-LC OM3 MMF Cable
00MN517ASRBLenovo 25m LC-LC OM3 MMF Cable
00MN520ASRCLenovo 30m LC-LC OM3 MMF Cable
OM4 LC to LC Cables
4Z57A10845B2P9Lenovo 0.5m LC-LC OM4 MMF Cable
4Z57A10846B2PALenovo 1m LC-LC OM4 MMF Cable
4Z57A10847B2PBLenovo 3m LC-LC OM4 MMF Cable
4Z57A10848B2PCLenovo 5m LC-LC OM4 MMF Cable
4Z57A10849B2PDLenovo 10m LC-LC OM4 MMF Cable
4Z57A10850B2PELenovo 15m LC-LC OM4 MMF Cable
4Z57A10851B2PFLenovo 25m LC-LC OM4 MMF Cable
4Z57A10852B2PGLenovo 30m LC-LC OM4 MMF Cable

Key features

Security

Today IT managers rely on Fibre Channel with field-proven security for the world’s mission-critical data in banking, finance, health care, government, transportation, and military. FC offers air gap protection with no connectivity to vulnerable IP networks.

Emulex Secure HBAs introduce a cost-effective, easy-to-manage solution that encrypts all data in-flight (EDIF), protecting data as it moves across databases, applications, servers, and storage. Emulex Secure HBAs integrate the most robust quantum-resistant algorithms to ensure that encrypted data remains encrypted even as quantum computing and AI put legacy encryption at risk.

The session-based key management solution, based on the emerging ANSI/INCITS FC-SP-3 standard, does not require complex and prohibitively expensive key management software. Compared to other encryption methods, such as application-based encryption, Emulex Secure HBAs can encrypt all applications, at a lower cost, and with no impact to storage array services such as compression, dedupe, and ransomware detection.

Performance

Compared to alternative approaches to network encryption that significantly impact application performance or limit the ability to compress or dedupe data, the Emulex Secure HBA delivers network encryption with better performance and no impact to storage services. The Emulex Dynamic Multi-core architecture delivers unparalleled performance and the most efficient port utilization with 8 fully redundant data engines and 16 threads that dynamically apply ASIC resources to any port that requires them, ensuring that SLAs are met.

Compared to Gen 6 HBAs, Emulex Gen 7 HBAs can support 64GFC to deliver up to 2x greater bandwidth. The Gen 7 HBAs deliver 12,800 MB/s (two 32GFC ports) or 25,600 MB/s (two 64GFC ports) full duplex; they deliver 3x better hardware latency; and the 64GFC LPe38100-series HBAs deliver industry-leading performance over 10 million IOPS.

LPe38100-series is available with dual 64GFC optics (installed) with backward compatibility to 32GFC and 16GFC networks. LPe37100-series is available with dual 32GFC optics (installed) with backward compatibility to 16GFC and 8GFC networks.

Operational Efficiency

Emulex Gen 7 HBAs offer enhanced reliability, availability, and serviceability (RAS), including port isolation and port-based error isolation that enable users to easily detect, isolate, and recover from errors.

Emulex HBAs fully support industry standards that enhance Broadcom® autonomous SAN innovations (Broadcom Autonomous Self-healing SANs) to self-learn, self-optimize, and self-heal, proactively keeping the SAN running at maximum speed and avoiding downtime. The new industry standards supported by Emulex HBAs around Fabric Performance Impact Notifications (FPINs) include Link Integrity notification (FPINLI), Congestion notification (FPIN-CN), Peer Congestion notification (FPIN-PN), and Delivery notification (FPIN-DN). The Emulex SAN Manager application is the first application in the industry to automatically identify, minimize, and mitigate application performance problems caused by SAN congestion by utilizing the FPIN-CN standard.

Emulex HBAs are easy to manage and save administrators time and operating costs with features such as no reboots for firmware updates, queue depth changes, or optics replacements. Emulex Gen 7 hot-plug (hot-swappable) optics enable optics to be removed and replaced without shutting down the system, allowing for uninterrupted service. The Emulex HBA Manager application provides centralized management of current and previous generations of Emulex FC HBAs. Emulex HBA troubleshooting is simplified with Emulex HBA Capture, an Emulex utility that gathers system, adapter, and device driver information. Data collected by HBA Capture is compressed into a single file and can be sent to Broadcom Technical Support for analysis when debugging system issues or for diagnostic purposes.

Emulex HBAs fully support the Brocade® Fabric Vision® suite of features, facilitating a solution from the switch to the server endpoints that have Emulex HBAs installed. Supported features include ClearLink™ (D_Port), Link Cable Beaconing, Host Name Registration, Read Diagnostic Parameters, VMID, BB Credit Recovery, FC Trace Route, FC Ping, REST APIs, and more. Visit www.broadcom.com for additional information on supported Fabric Vision features.

Technical specifications

Emulex Secure FC HBAs are powered by the XE701 SEC controller and use PCIe 4.0 x8 host connection. The architecture enables resources to be applied to any port that needs them, delivering up to 10M IOPS for Gen 7 64GFC HBAs.

Throughput:

  • 32GFC: 6,400 MB/s full-duplex line rate per port
  • 64GFC: 12,800 MB/s full-duplex line rate per port

Optical:

  • Data rates, automatically detected:
    • 64GFC (28.9 Gbaud PAM4) (LPe38100-series only)
    • 32GFC (28.05 Gbaud NRZ)
    • 16GFC (14.025 Gbaud NRZ)
    • 8GFC (8.5 Gbaud NRZ) (LPe37100-series only)
  • Optics: Short-wave lasers with LC-type connectors

Performance Features

  • Support for NVMe/FC for lowlatency, high-performance, end-to-end NVMe/FC storage networks.
  • Registration and support for FPINs and congestion signaling.
  • Buffer-to-buffer credit recovery: automatic buffer credit loss detection and recovery for reliable performance.
  • Frame-level multiplexing increases link efficiency and maximizes HBA performance.
  • N_Port ID Virtualization (NPIV) increases network scalability by enabling a single FC adapter port to provide multiple virtual ports.
  • Enhanced data protection is provided by T10 PI with highperformance offload. T10 PI provides additional data protection in environments such as Oracle Unbreakable Linux.

Industry Standards:

  • Current ANSI/INCITS standards: FC-PI-8; FC-FS-6; FC-LS-5; FC-GS-9; FCP-5; FC-SP-2; FC-SP-3 INCITS 577-202x rev 3.04; SPC-5; SBC-4; SSC-5; FC-NVMe-2
  • Legacy ANSI/INCITS standards: – FC-PI-1/2/3/4/5/6/7; FC-FS-1/2/3/4/5; FC-LS-1/2/3/4; FC-GS-1/2/3/4/5/6/7/8; FC-PH-1/2/3; FC-DA-1/2; FCP-2/3/4; FC-HBA; FC-TAPE; FC-MI; SPC-3/4; SBC-2/3; SSC-2/3/4; FC-NVMe with AM1
  • DMTF management standards, specifications: – DSP0222 (NC-SI); DSP0261 (NCSI over MCTP Binding); DSP2037 (MCTP Packets and NC-SI over MCTP Overview); DSP0237 (MCTP SMBus/I2C Transport Binding); DSP0240 (PLDM Base Spec); DSP0248 (PLDM Platform Monitoring and Control); DSP0257 (PLDM for FRU Data); DSP0267 (PLDM for FW Update); DSP0274 (Security and Data Model, SPDM); DSP0275 (SPDM over MCTP Binding); DSP0266 (Redfish, RDE Spec)
  • PCIe base spec 4.0
  • PCIe card electromechanical spec 4.0
  • UEFI 2.7

HBA Port Virtualization (NPIV):

  • Support for NPIV

Logins, Exchanges

  • Support for 2048 concurrent logins (RPIs) and 6000 active exchanges (XRIs) per port
  • Boot from SAN (BFS)

Zero Trust Security Features:

  • Secure boot and signed drivers
  • Security Protocol and Data Model (SPDM)
  • Post-Quantum Silicon Root of Trust (Leighton-Micali Signature, LMS)
  • Data Encryption In-Flight (EDIF, AES-GCM-256)
  • Support for Post-Quantum Digital Signature and Key Exchange Method (FIPS 203, 204)
  • CNSA (Commercial National Security Algorithm Suite) Compliant

Server support

The following tables list the ThinkSystem servers that are compatible.

Table 3. Server support (Part 1 of 4)
Part Number Description AMD V3 2S Intel V3/V4 4S 8S Intel V3 Multi Node V3/V4 1S V3
SR635 V3 (7D9H / 7D9G)
SR655 V3 (7D9F / 7D9E)
SR645 V3 (7D9D / 7D9C)
SR665 V3 (7D9B / 7D9A)
ST650 V3 (7D7B / 7D7A)
SR630 V3 (7D72 / 7D73)
SR650 V3 (7D75 / 7D76)
SR630 V4 (7DG8 / 7DG9)
SR650 V4 (7DGC / 7DGD)
SR650a V4 (7DGC / 7DGD)
SR850 V3 (7D97 / 7D96)
SR860 V3 (7D94 / 7D93)
SR950 V3 (7DC5 / 7DC4)
SD535 V3 (7DD8 / 7DD1)
SD530 V3 (7DDA / 7DD3)
SD550 V3 (7DD9 / 7DD2)
ST45 V3 (7DH4 / 7DH5)
ST50 V3 (7DF4 / 7DF3)
ST250 V3 (7DCF / 7DCE)
SR250 V3 (7DCM / 7DCL)
4XC7A96457 ThinkSystem Emulex LPe37102 32Gb 2-Port PCIe Fibre Channel Adapter N N N N N N N Y Y Y N N N N N N N N N N
4XC7A96458 ThinkSystem Emulex LPe38102 64Gb 2-Port PCIe Fibre Channel Adapter N N N N N N N Y Y Y N N N N N N N N N N
Table 4. Server support (Part 2 of 4)
Part Number Description GPU Rich Edge Super Computing 1S Intel V2
SR670 V2 (7Z22 / 7Z23)
SR675 V3 (7D9Q / 7D9R)
SR680a V3 (7DHE)
SR685a V3 (7DHC)
SR780a V3 (7DJ5)
SE350 (7Z46 / 7D1X)
SE350 V2 (7DA9)
SE360 V2 (7DAM)
SE450 (7D8T)
SE455 V3 (7DBY)
SC750 V4 (7DDJ)
SC777 V4 (7DKA)
SD665 V3 (7D9P)
SD665-N V3 (7DAZ)
SD650 V3 (7D7M)
SD650-I V3 (7D7L)
SD650-N V3 (7D7N)
ST50 V2 (7D8K / 7D8J)
ST250 V2 (7D8G / 7D8F)
SR250 V2 (7D7R / 7D7Q)
4XC7A96457 ThinkSystem Emulex LPe37102 32Gb 2-Port PCIe Fibre Channel Adapter N N N N N N N N N N N N N N N N N N N N
4XC7A96458 ThinkSystem Emulex LPe38102 64Gb 2-Port PCIe Fibre Channel Adapter N N N N N N N N N N N N N N N N N N N N
Table 5. Server support (Part 3 of 4)
Part Number Description 2S Intel V2 AMD V1 Dense V2 4S V2 8S 4S V1
ST650 V2 (7Z75 / 7Z74)
SR630 V2 (7Z70 / 7Z71)
SR650 V2 (7Z72 / 7Z73)
SR635 (7Y98 / 7Y99)
SR655 (7Y00 / 7Z01)
SR655 Client OS
SR645 (7D2Y / 7D2X)
SR665 (7D2W / 7D2V)
SD630 V2 (7D1K)
SD650 V2 (7D1M)
SD650-N V2 (7D1N)
SN550 V2 (7Z69)
SR850 V2 (7D31 / 7D32)
SR860 V2 (7Z59 / 7Z60)
SR950 (7X11 / 7X12)
SR850 (7X18 / 7X19)
SR850P (7D2F / 2D2G)
SR860 (7X69 / 7X70)
4XC7A96457 ThinkSystem Emulex LPe37102 32Gb 2-Port PCIe Fibre Channel Adapter N N N N N N N N N N N N N N N N N N
4XC7A96458 ThinkSystem Emulex LPe38102 64Gb 2-Port PCIe Fibre Channel Adapter N N N N N N N N N N N N N N N N N N
Table 6. Server support (Part 4 of 4)
Part Number Description 1S Intel V1 2S Intel V1 Dense V1
ST50 (7Y48 / 7Y50)
ST250 (7Y45 / 7Y46)
SR150 (7Y54)
SR250 (7Y52 / 7Y51)
ST550 (7X09 / 7X10)
SR530 (7X07 / 7X08)
SR550 (7X03 / 7X04)
SR570 (7Y02 / 7Y03)
SR590 (7X98 / 7X99)
SR630 (7X01 / 7X02)
SR650 (7X05 / 7X06)
SR670 (7Y36 / 7Y37)
SD530 (7X21)
SD650 (7X58)
SN550 (7X16)
SN850 (7X15)
4XC7A96457 ThinkSystem Emulex LPe37102 32Gb 2-Port PCIe Fibre Channel Adapter N N N N N N N N N N N N N N N N
4XC7A96458 ThinkSystem Emulex LPe38102 64Gb 2-Port PCIe Fibre Channel Adapter N N N N N N N N N N N N N N N N

SAN switches

Lenovo offers the ThinkSystem DB Series of Fibre Channel SAN switches for high-performance storage expansion. See the DB Series product guides for models and configuration options:

Warranty

The adapters carry a one-year limited warranty. When installed in a supported server, the adapters assume the server’s base warranty and any Lenovo Services warranty upgrade.

Physical specifications

The adapters have the following dimensions:

  • Length: 168 mm
  • Height: 69 mm

Operating environment

The adapters are supported in the following environment:

  • Temperature:
    • Operating: 0 to 55 °C (32 to 131 °F)
    • Storage: -20 to 85 °C (-4 to 185 °F)
  • Relative humidity: 5 - 95% (non-condensing)

Agency approvals

The adapters conform to the following regulations:

  • North America
    • FCC/ICES Class A
    • UL/CSA Recognized
  • Europe
    • CE Mark
    • UKCA Mark
    • EU RoHS Compliant
    • EU Low Voltage Directive
  • Australia
    • RCM Class A
  • Japan
    • VCCI Class A
  • Korea
    • KCC Class A
  • China
    • China RoHS Compliant
  • Taiwan
    • BSMI Class A
    • BSMI RoHS Compliant

Related product families

Product families related to this document are the following:

Trademarks

Lenovo and the Lenovo logo are trademarks or registered trademarks of Lenovo in the United States, other countries, or both. A current list of Lenovo trademarks is available on the Web at https://www.lenovo.com/us/en/legal/copytrade/.

The following terms are trademarks of Lenovo in the United States, other countries, or both:
Lenovo®
ServerProven®
ThinkSystem®

The following terms are trademarks of other companies:

AMD is a trademark of Advanced Micro Devices, Inc.

Intel® is a trademark of Intel Corporation or its subsidiaries.

Linux® is the trademark of Linus Torvalds in the U.S. and other countries.

Other company, product, or service names may be trademarks or service marks of others.