Abstract
The Lenovo PX04PMC NVMe Enterprise Mainstream Flash Adapters in capacities of 1.92 TB and 3.84 TB are advanced data center PCIe Flash Storage Adapters optimized for mixed read-write performance, endurance, and strong data protection for System x and ThinkServer systems. They are engineered for greater performance and endurance in a cost-effective design, and to support a broader set of workloads.
This product guide provides essential presales information to understand the NVMe Enterprise Mainstream Flash Adapters and their key features, specifications, and compatibility. This guide is intended for technical specialists, sales specialists, sales engineers, IT architects, and other IT professionals who want to learn more about the Flash Storage Adapters and consider their use in IT solutions.
Withdrawn: The flash storage adapters listed in this product guide are now withdrawn from marketing.
Introduction
The Lenovo PX04PMC NVMe Enterprise Mainstream Flash Adapters in capacities of 1.92 TB and 3.84 TB are advanced data center PCIe Flash Storage Adapters optimized for mixed read-write performance, endurance, and strong data protection for System x and ThinkServer systems. They are engineered for greater performance and endurance in a cost-effective design, and to support a broader set of workloads.
Suggested uses: Data warehousing, Web servers, Media streaming, and Video on Demand (VOD).
Figure 1. Lenovo NVMe Enterprise Mainstream Flash Adapters
Did you know?
NVMe (Non-Volatile Memory Express) is a technology that overcomes SAS/SATA SSD performance limitations by optimizing hardware and software to take full advantage of flash technology. The use of NVMe Flash Storage Adapters means data is transferred more efficiently from the processor to the storage compared to the legacy Advance Host Controller Interface (AHCI) stack, thereby reducing latency and overhead. These Flash Storage Adapters connect directly to the processor via the PCIe bus, further reducing latency and TCO compared to SAS/SATA SSDs.
Lenovo Enterprise Mainstream Flash Adapters are suitable for mixed read-write and general-purpose data center workloads, however their NVMe PCIe interface means the adapters also offer high performance. Overall, these adapters provide outstanding IOPS/watt and cost/IOPS for enterprise solutions.
Part number information
The following tables list the part numbers to order the adapters.
Withdrawn: All adapters are now withdrawn from marketing.
Part number | Feature code | Description |
---|---|---|
7N47A00097 | AUUP | ThinkSystem HHHL PX04PMC 1.92TB Mainstream NVMe PCIe 3.0 x4 Flash Adapter |
7N47A00098 | AUVY | ThinkSystem HHHL PX04PMC 3.84TB Mainstream NVMe PCIe 3.0 x4 Flash Adapter |
Part number | Feature code | Description |
---|---|---|
00YK286 | AVP3 | 1.92TB NVMe Enterprise Mainstream Flash Adapter |
00YK287 | AVP4 | 3.84TB NVMe Enterprise Mainstream Flash Adapter |
Part number | Description |
---|---|
4XB0K12394 | ThinkServer 1.92TB NVMe Enterprise Mainstream Flash Adapter |
4XB0K12395 | ThinkServer 3.84TB NVMe Enterprise Mainstream Flash Adapter |
The part numbers include the following items:
- One adapter with full-height (3U) PCIe bracket attached
- Separate low-profile (2U) PCIe bracket
- Warranty flyer and Important Notices document
- Support flyer for solid-state devices (System x options only)
Features
Non-Volatile Memory Express (NVMe) is new PCIe 3.0 high performance solid-state storage technology that provides high I/O throughput and low latency. NVMe interfaces remove SAS/SATA bottlenecks and unleash all of the capabilities of contemporary NAND flash memory. Each Flash Storage Adapter has direct PCIe 3.0 x4 connection, which provides at least 2x more bandwidth and 2x less latency than SATA/SAS-based SSD solutions. NVMe Flash Storage Adapters are also optimized for heavy multi-threaded workloads by using internal parallelism and many other improvements, such as enlarged I/O queues.
The Lenovo NVMe Enterprise Mainstream Flash Adapters have the following features:
- Half-high half-length PCIe adapter with PCIe 3.0 x4 host interface
- Based on the Toshiba PX04P Add-in Card (AIC), PX04PMCxxx
- 19nm MLC NAND (128 Gb/die)
- 3 drive-write-per-day (DWPD) endurance for mixed read-write workloads
- Full Power-Loss-Protection and End-to-End Data Protection
- Low power consumption (maximum 18.5 W)
Enterprise Mainstream Flash Adapters and Enterprise Performance Flash Adapters have similar read IOPS performance, but the key difference between them is their endurance (or lifetime) (that is, how long they can perform write operations because Flash Adapters (like SSDs) have a finite number of program/erase (P/E) cycles). Enterprise Mainstream Flash Adapters have a better cost/IOPS ratio but lower endurance compared to Enterprise Performance Flash Adapters. Write endurance is typically measured by the number of program/erase (P/E) cycles that the adapter incurs over its lifetime, listed as the total bytes of written data (TBW) in the device specification.
The TBW value assigned to a Flash Adapter is the total bytes of written data (based on the number of P/E cycles) that an adapter can be guaranteed to complete (% of remaining P/E cycles = % of remaining TBW). Reaching this limit does not cause the adapter to immediately fail. It simply denotes the maximum number of writes that can be guaranteed. A Flash Adapter will not fail upon reaching the specified TBW. At some point based on manufacturing variance margin, after surpassing the TBW value, the adapter will reach the end-of-life point, at which the adapter will go into a read-only mode.
Because of such behavior by Enterprise Mainstream Flash Adapters, careful planning must be done to use them only in mixed read-write environments to ensure that the TBW of the adapter will not be exceeded before the required life expectancy.
For example, the 1.92TB NVMe Enterprise Mainstream Flash Adapter has an endurance of 10,412 TB of total bytes written (TBW). This means that for full operation over five years, write workload must be limited to no more than 5,705 GB of writes per day, which is equivalent to 3.0 full "drive" writes per day (DWPD). For the device to last three years, the write workload must be limited to no more than 9,509 GB of writes per day, which is equivalent to 5.0 full drive writes per day.
Technical specifications
The following tables present technical specifications for the NVMe Enterprise Mainstream Flash Adapters.
Feature | 1.92 TB adapter | 3.84 TB adapter |
---|---|---|
Interface | PCIe 3.0 x4 | PCIe 3.0 x4 |
Capacity | 1.92 TB | 3.84 TB |
Endurance (total bytes written) | 10,512 TB | 21,024 TB |
Endurance (drive writes per day for 5 years) | 3.0 DWPD | 3.0 DWPD |
Data reliability (UBER) | < 1 in 1017 bits read | < 1 in 1017 bits read |
MTBF | 2,000,000 hours | 2,000,000 hours |
IOPS reads (4 KB blocks) | 660,000 | 660,000 |
IOPS writes (4 KB blocks) | 105,000 | 105,000 |
Sequential read rate (128 KB blocks) | 3100 MBps | 3100 MBps |
Sequential write rate (128 KB blocks) | 2350 MBps | 2350 MBps |
Latency (random read) | 100 µs | 100 µs |
Latency (random write) | 30 µs | 30 µs |
Maximum power | 18.5 W | 18.5 W |
Server support - ThinkSystem
The following table lists the ThinkSystem servers that are compatible.
Part number |
Description | 2S Rack & Tower | 4S Rack | Dense/ Blade |
||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ST550 (7X09/7X10)
|
SR530 (7X07/7X08)
|
SR550 (7X03/7X04)
|
SR570 (7Y02/7Y03)
|
SR590 (7X98/7X99)
|
SR630 (7X01/7X02)
|
SR650 (7X05/7X06)
|
SR850 (7X18/7X19)
|
SR860 (7X69/7X70)
|
SR950 (7X11/12/13)
|
SD530 (7X21)
|
SN550 (7X16)
|
SN850 (7X15)
|
||
7N47A00097 | ThinkSystem HHHL PX04PMC 1.92TB Mainstream NVMe PCIe 3.0 x4 Flash Adapter | N | N | N | N | N | Y | Y | Y | Y | Y | Y | N | N |
7N47A00098 | ThinkSystem HHHL PX04PMC 3.84TB Mainstream NVMe PCIe 3.0 x4 Flash Adapter | N | N | N | N | N | Y | Y | Y | Y | Y | Y | N | N |
Server support - System x
The following tables list the System x servers that are compatible.
Support for System x and dense servers with Xeon E5/E7 v4 and E3 v5 processors
Part number |
Description |
x3250 M6 (3943)
|
x3250 M6 (3633)
|
x3550 M5 (8869)
|
x3650 M5 (8871)
|
x3850 X6/x3950 X6 (6241, E7 v4)
|
nx360 M5 (5465, E5-2600 v4)
|
sd350 (5493)
|
---|---|---|---|---|---|---|---|---|
00YK286 | 1.92TB NVMe Enterprise Mainstream Flash Adapter | N | N | Y | Y | Y | N | N |
00YK287 | 3.84TB NVMe Enterprise Mainstream Flash Adapter | N | N | Y | Y | Y | N | N |
Support for System x and dense servers with Intel Xeon v3 processors
Part number |
Description |
x3100 M5 (5457)
|
x3250 M5 (5458)
|
x3500 M5 (5464)
|
x3550 M5 (5463)
|
x3650 M5 (5462)
|
x3850 X6/x3950 X6 (6241, E7 v3)
|
nx360 M5 (5465)
|
---|---|---|---|---|---|---|---|---|
00YK286 | 1.92TB NVMe Enterprise Mainstream Flash Adapter | N | N | N | N | N | N | N |
00YK287 | 3.84TB NVMe Enterprise Mainstream Flash Adapter | N | N | N | N | N | N | N |
Server support - ThinkServer
The following tables list the ThinkServer systems that are compatible.
Support for ThinkServer Gen 5 servers with E5 v4 or E3 v5 processors
Support for sd350: The adapters supported with the sd350 are listed in Table 4.
Part number | Description |
TS150 (E3 v5)
|
TS450 (E3 v5)
|
RS160 (E3 v5)
|
TD350 (E5 v4)
|
RD350 (E5 v4)
|
RD450 (E5 v4)
|
RD550 (E5 v4)
|
RD650 (E5 v4)
|
---|---|---|---|---|---|---|---|---|---|
4XB0K12394 | ThinkServer 1.92TB NVMe Enterprise Mainstream Flash Adapter | N | N | N | N | N | N | Y | Y |
4XB0K12395 | ThinkServer 3.84TB NVMe Enterprise Mainstream Flash Adapter | N | N | N | N | N | N | Y | Y |
Support for ThinkServer Gen 5 servers with E5 v3 processors
Part number | Description |
TS140
|
TS440
|
RS140
|
TD350 (E5 v3)
|
RD350 (E5 v3)
|
RD450 (E5 v3)
|
RD550 (E5 v3)
|
RD650 (E5 v3)
|
RQ750 (E5 v3)
|
---|---|---|---|---|---|---|---|---|---|---|
4XB0K12394 | ThinkServer 1.92TB NVMe Enterprise Mainstream Flash Adapter | N | N | N | N | N | N | N | N | N |
4XB0K12395 | ThinkServer 3.84TB NVMe Enterprise Mainstream Flash Adapter | N | N | N | N | N | N | N | N | N |
Operating system support
The following tables list the supported operating systems
- ThinkSystem HHHL PX04PMC 1.92TB Mainstream NVMe PCIe 3.0 x4 Flash Adapter, 7N47A00097
- ThinkSystem HHHL PX04PMC 3.84TB Mainstream NVMe PCIe 3.0 x4 Flash Adapter, 7N47A00098
Tip: These tables are automatically generated based on data from Lenovo ServerProven.
Operating systems | SD530 (Xeon Gen 2) |
SR630 (Xeon Gen 2) |
SR650 (Xeon Gen 2) |
SR850 (Xeon Gen 2) |
SR860 (Xeon Gen 2) |
SR950 (Xeon Gen 2) |
SD530 (Xeon Gen 1) |
SR630 (Xeon Gen 1) |
SR650 (Xeon Gen 1) |
SR850 (Xeon Gen 1) |
SR860 (Xeon Gen 1) |
SR950 (Xeon Gen 1) |
---|---|---|---|---|---|---|---|---|---|---|---|---|
Microsoft Windows Server 2012 R2 | N | N | N | N | N | N | Y | Y | Y | Y | Y | Y |
Microsoft Windows Server 2016 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Microsoft Windows Server 2019 | Y | Y | Y | Y | Y | Y | N | Y | N | N | N | Y |
Microsoft Windows Server 2022 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Microsoft Windows Server version 1709 | N | N | N | N | N | N | Y | Y | Y | Y | Y | Y |
Microsoft Windows Server version 1803 | N | N | N | N | N | N | Y | Y | Y | Y | Y | Y |
Red Hat Enterprise Linux 6.10 | N | N | N | N | N | N | Y | Y | Y | Y | Y | Y |
Red Hat Enterprise Linux 6.9 | N | N | N | N | N | N | Y | Y | Y | Y | Y | Y |
Red Hat Enterprise Linux 7.3 | N | N | N | N | N | N | Y | Y | Y | Y | N | Y |
Red Hat Enterprise Linux 7.4 | N | N | N | N | N | N | Y | Y | Y | Y | Y | Y |
Red Hat Enterprise Linux 7.5 | N | N | N | N | N | N | Y | Y | Y | Y | Y | Y |
Red Hat Enterprise Linux 7.6 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Red Hat Enterprise Linux 7.7 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Red Hat Enterprise Linux 7.8 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Red Hat Enterprise Linux 7.9 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Red Hat Enterprise Linux 8.0 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Red Hat Enterprise Linux 8.1 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Red Hat Enterprise Linux 8.2 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Red Hat Enterprise Linux 8.3 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Red Hat Enterprise Linux 8.4 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Red Hat Enterprise Linux 8.5 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Red Hat Enterprise Linux 9.0 | Y | Y | Y | Y | Y | Y | N | N | N | N | N | N |
SUSE Linux Enterprise Server 11 SP4 | N | N | N | N | N | N | Y | Y | Y | Y | Y | Y |
SUSE Linux Enterprise Server 11 SP4 with Xen | N | N | N | N | N | N | Y | Y | Y | Y | Y | Y |
SUSE Linux Enterprise Server 12 SP2 | N | N | N | N | N | N | Y | Y | Y | Y | N | Y |
SUSE Linux Enterprise Server 12 SP2 with Xen | N | N | N | N | N | N | Y | Y | Y | Y | N | Y |
SUSE Linux Enterprise Server 12 SP3 | N | N | N | N | N | N | Y | Y | Y | Y | Y | Y |
SUSE Linux Enterprise Server 12 SP3 with Xen | N | N | N | N | N | N | Y | Y | Y | Y | Y | Y |
SUSE Linux Enterprise Server 12 SP4 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
SUSE Linux Enterprise Server 12 SP4 with Xen | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
SUSE Linux Enterprise Server 12 SP5 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
SUSE Linux Enterprise Server 12 SP5 with Xen | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
SUSE Linux Enterprise Server 15 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
SUSE Linux Enterprise Server 15 SP1 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
SUSE Linux Enterprise Server 15 SP1 with Xen | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
SUSE Linux Enterprise Server 15 SP2 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
SUSE Linux Enterprise Server 15 SP2 with Xen | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
SUSE Linux Enterprise Server 15 SP3 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
SUSE Linux Enterprise Server 15 SP3 with Xen | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
SUSE Linux Enterprise Server 15 SP4 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
SUSE Linux Enterprise Server 15 SP4 with Xen | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
SUSE Linux Enterprise Server 15 with Xen | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Ubuntu 22.04 LTS | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
VMware vSphere Hypervisor (ESXi) 6.0 U3 | N | N | N | N | N | N | Y | Y | Y | Y | Y | Y |
VMware vSphere Hypervisor (ESXi) 6.5 | N | N | N | N | N | N | Y | Y | Y | Y | N | Y |
VMware vSphere Hypervisor (ESXi) 6.5 U1 | N | N | N | N | N | N | Y | Y | Y | Y | Y | Y |
VMware vSphere Hypervisor (ESXi) 6.5 U2 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
VMware vSphere Hypervisor (ESXi) 6.7 | N | N | N | N | N | N | Y | Y | Y | Y | Y | Y |
VMware vSphere Hypervisor (ESXi) 6.7 U2 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
VMware vSphere Hypervisor (ESXi) 7.0 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
VMware vSphere Hypervisor (ESXi) 7.0 U1 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
VMware vSphere Hypervisor (ESXi) 7.0 U2 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
VMware vSphere Hypervisor (ESXi) 7.0 U3 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
VMware vSphere Hypervisor (ESXi) 8.0 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Operating systems | SD530 (Xeon Gen 2) |
SR630 (Xeon Gen 2) |
SR650 (Xeon Gen 2) |
SR850 (Xeon Gen 2) |
SR860 (Xeon Gen 2) |
SR950 (Xeon Gen 2) |
SD530 (Xeon Gen 1) |
SR630 (Xeon Gen 1) |
SR650 (Xeon Gen 1) |
SR850 (Xeon Gen 1) |
SR860 (Xeon Gen 1) |
SR950 (Xeon Gen 1) |
---|---|---|---|---|---|---|---|---|---|---|---|---|
Microsoft Windows Server 2012 R2 | N | N | N | N | N | N | Y | Y | Y | Y | Y | Y |
Microsoft Windows Server 2016 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Microsoft Windows Server 2019 | Y | Y | Y | Y | Y | Y | N | Y | N | N | N | Y |
Microsoft Windows Server 2022 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Microsoft Windows Server version 1709 | N | N | N | N | N | N | Y | Y | Y | Y | Y | Y |
Microsoft Windows Server version 1803 | N | N | N | N | N | N | Y | Y | Y | Y | Y | Y |
Red Hat Enterprise Linux 6.10 | N | N | N | N | N | N | Y | Y | Y | Y | Y | Y |
Red Hat Enterprise Linux 6.9 | N | N | N | N | N | N | Y | Y | Y | Y | Y | Y |
Red Hat Enterprise Linux 7.3 | N | N | N | N | N | N | Y | Y | Y | Y | N | Y |
Red Hat Enterprise Linux 7.4 | N | N | N | N | N | N | Y | Y | Y | Y | Y | Y |
Red Hat Enterprise Linux 7.5 | N | N | N | N | N | N | Y | Y | Y | Y | Y | Y |
Red Hat Enterprise Linux 7.6 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Red Hat Enterprise Linux 7.7 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Red Hat Enterprise Linux 7.8 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Red Hat Enterprise Linux 7.9 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Red Hat Enterprise Linux 8.0 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Red Hat Enterprise Linux 8.1 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Red Hat Enterprise Linux 8.2 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Red Hat Enterprise Linux 8.3 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Red Hat Enterprise Linux 8.4 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Red Hat Enterprise Linux 8.5 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Red Hat Enterprise Linux 9.0 | Y | Y | Y | Y | Y | Y | N | N | N | N | N | N |
SUSE Linux Enterprise Server 11 SP4 | N | N | N | N | N | N | Y | Y | Y | Y | Y | Y |
SUSE Linux Enterprise Server 11 SP4 with Xen | N | N | N | N | N | N | Y | Y | Y | Y | Y | Y |
SUSE Linux Enterprise Server 12 SP2 | N | N | N | N | N | N | Y | Y | Y | Y | N | Y |
SUSE Linux Enterprise Server 12 SP2 with Xen | N | N | N | N | N | N | Y | Y | Y | Y | N | Y |
SUSE Linux Enterprise Server 12 SP3 | N | N | N | N | N | N | Y | Y | Y | Y | Y | Y |
SUSE Linux Enterprise Server 12 SP3 with Xen | N | N | N | N | N | N | Y | Y | Y | Y | Y | Y |
SUSE Linux Enterprise Server 12 SP4 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
SUSE Linux Enterprise Server 12 SP4 with Xen | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
SUSE Linux Enterprise Server 12 SP5 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
SUSE Linux Enterprise Server 12 SP5 with Xen | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
SUSE Linux Enterprise Server 15 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
SUSE Linux Enterprise Server 15 SP1 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
SUSE Linux Enterprise Server 15 SP1 with Xen | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
SUSE Linux Enterprise Server 15 SP2 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
SUSE Linux Enterprise Server 15 SP2 with Xen | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
SUSE Linux Enterprise Server 15 SP3 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
SUSE Linux Enterprise Server 15 SP3 with Xen | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
SUSE Linux Enterprise Server 15 SP4 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
SUSE Linux Enterprise Server 15 SP4 with Xen | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
SUSE Linux Enterprise Server 15 with Xen | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Ubuntu 22.04 LTS | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
VMware vSphere Hypervisor (ESXi) 6.0 U3 | N | N | N | N | N | N | Y | Y | Y | Y | Y | Y |
VMware vSphere Hypervisor (ESXi) 6.5 | N | N | N | N | N | N | Y | Y | Y | Y | N | Y |
VMware vSphere Hypervisor (ESXi) 6.5 U1 | N | N | N | N | N | N | Y | Y | Y | Y | Y | Y |
VMware vSphere Hypervisor (ESXi) 6.5 U2 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
VMware vSphere Hypervisor (ESXi) 6.7 | N | N | N | N | N | N | Y | Y | Y | Y | Y | Y |
VMware vSphere Hypervisor (ESXi) 6.7 U2 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
VMware vSphere Hypervisor (ESXi) 7.0 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
VMware vSphere Hypervisor (ESXi) 7.0 U1 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
VMware vSphere Hypervisor (ESXi) 7.0 U2 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
VMware vSphere Hypervisor (ESXi) 7.0 U3 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
VMware vSphere Hypervisor (ESXi) 8.0 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Warranty
The NVMe Enterprise Mainstream Flash Adapters carry a one-year, customer-replaceable unit (CRU) limited warranty. When the adapters are installed in a supported server, these adapters assume the system’s base warranty and any warranty upgrades.
Solid State Memory cells have an intrinsic, finite number of program/erase cycles that each cell can incur. As a result, each solid state device has a maximum amount of program/erase cycles to which it can be subjected. The warranty for Lenovo Flash Storage Adapters is limited to adapters that have not reached the maximum guaranteed number of program/erase cycles, as documented in the Official Published Specifications for the product. An adapter that reaches this limit may fail to operate according to its Specifications.
Physical specifications
The NVMe Enterprise Mainstream Flash Adapters have the following physical specifications:
Dimensions and weight:
- Height: 69 mm (2.7 in.)
- Length: 168 mm (6.6 in.)
- Depth: 19 mm (0.74 in.)
- Weight: 220 g (7.8 oz)
Operating environment
The NVMe Enterprise Mainstream Flash Adapters are supported in the following environment:
- Temperature:
- Operating: 0 to 50 °C (32 to 122 °F)
- Non-operating: -40 to 70 °C (-40 to 158 °F)
- Transport: -40 to 70 °C (-40 to 158 °F)
- Relative humidity: 5 to 95% (non-condensing)
- Maximum altitude:
- Operating: 5,486 m (18,000 ft)
- Non-operating: 12,192 m (40,000 ft)
- Shock: 400 G (Max) at 2 ms
- Vibration: 2.17 GRMS (5-800 Hz)
Agency approvals
The NVMe Enterprise Mainstream Flash Adapters conform to the following regulations:
- Underwriters Laboratories: UL60950-1
- Canada: CAN/CSA-C22.2 No.60950-1
- TUV: EN 60950-1
- BSMI (Taiwan): CNS 13438 (CISPR Pub. 22 Class B): D33003
- MSIP: KN22, KN24 (CISPR Pub. 22 Class B)
- Australia/New Zealand: AS/NZS CISPR22
- EMC: EN55022 (2010) Class B
- EMC: EN55024 (2010)
- RoHS 2011/65/EU: EN50581 (2012) Category 3
Related product families
Product families related to this document are the following:
Trademarks
Lenovo and the Lenovo logo are trademarks or registered trademarks of Lenovo in the United States, other countries, or both. A current list of Lenovo trademarks is available on the Web at https://www.lenovo.com/us/en/legal/copytrade/.
The following terms are trademarks of Lenovo in the United States, other countries, or both:
Lenovo®
ServerProven®
System x®
ThinkServer®
ThinkSystem®
The following terms are trademarks of other companies:
Intel® and Xeon® are trademarks of Intel Corporation or its subsidiaries.
Linux® is the trademark of Linus Torvalds in the U.S. and other countries.
Microsoft®, Windows Server®, and Windows® are trademarks of Microsoft Corporation in the United States, other countries, or both.
Other company, product, or service names may be trademarks or service marks of others.