Author
Updated
9 Oct 2019Form Number
LP0707PDF size
11 pages, 482 KBAbstract
The ThinkSystem QLogic QML2692 Mezz 16Gb 2-Port Fibre Channel Adapter is an Enhanced Generation 5 (Gen 5) 16 Gb FC adapter for ThinkSystem blade servers. The adapter, based on Cavium technology, offer industry leading native FC performance with extremely low CPU usage with full hardware offloads. Enhanced Gen 5 FC technology provides advanced storage networking features capable of supporting the most demanding virtualized and private cloud environments, while fully leveraging the capabilities of high-performance 16 Gb FC (16GFC) and all-flash arrays (AFAs).
This product guide provides essential presales information to understand the QLogic mezz adapter and its key features, specifications and compatibility. This guide is intended for technical specialists, sales specialists, sales engineers, IT architects, and other IT professionals who want to learn more about the adapter and consider its use in IT solutions.
Change History
Changes in the October 9 update:
- Operating system support information is now listed as tables which are automatically generated from ServerProven data - Operating systems section
Introduction
The ThinkSystem QLogic QML2692 Mezz 16Gb 2-Port Fibre Channel Adapter is an Enhanced Generation 5 (Gen 5) 16 Gb FC adapter for ThinkSystem blade servers. The adapter, based on Cavium technology, offer industry leading native FC performance with extremely low CPU usage with full hardware offloads. Enhanced Gen 5 FC technology provides advanced storage networking features capable of supporting the most demanding virtualized and private cloud environments, while fully leveraging the capabilities of high-performance 16 Gb FC (16GFC) and all-flash arrays (AFAs).
The following figure shows the ThinkSystem QLogic QML2692 Mezz 16Gb 2-Port Fibre Channel Adapter.
Figure 1. ThinkSystem QLogic QML2692 Mezz 16Gb 2-Port Fibre Channel Adapter
Did you know?
The Cavium StorFusion architecture delivers ultimate reliability to meet the needs of mission-critical enterprise applications with lower power and fewer CPU cycles, all while maintaining peak performance.
The QLogic 16Gb Enhanced Gen 5 mezz adapter is based on a 32 Gbps ASIC, which delivers higher IOPS and performance with lower power consumption compared to previous generation.
QLogic QConvergeConsole provides unified, single-pane-of-glass management across generations of QLogic FC adapters.
Part number information
The following table shows the part number to order these adapters.
Part number | Feature code | Description |
---|---|---|
7ZT7A00520 | AVCV | ThinkSystem QLogic QML2692 Mezz 16Gb 2-Port Fibre Channel Adapter |
The part number includes the following items:
- One Flex System mezz adapter
- Adapter documentation
Key features
The ThinkSystem QLogic QML2692 Mezz 16Gb 2-Port Fibre Channel Adapter has the following features:
- Maximum performance with up to 1.3 million input/output operations per second (IOPS) to support larger server virtualization deployments and scalable cloud initiatives, and performance to match new multicore processors, SSDs/flash storage, and faster server host bus architectures.
- Independent function, transmit and receive buffers, an on-chip CPU, DMA channels, and a firmware image for each port enable complete port-level isolation, prevent errors and firmware crashes from propagating across all ports, and provide predictable and scalable performance across all ports.
- Support forward error correction (FEC) to enhance reliability of transmission and thereby performance.
- Industry-standard class-specific control (CS_CTL)-based frame prioritization Quality of Service (QoS) helps alleviate network congestion by prioritizing traffic for time-sensitive mission critical workloads for optimized performance.
- T10-PI data integrity with high performance offload provides end-to-end data corruption protection.
- Support for Message Signaled Interrupts eXtended (MSI-X) improves host utilization and enhances application performance.
- Fabric-assigned port worldwide name (FA-WWN) and fabric-based boot LUN discovery (F-BLD) pre-provisioning services allow servers to be quickly deployed, replaced, and moved across the SAN; the creation of zones, LUNs, and other services can be completed before the servers arrive on site.
- Using the Brocade ClearLink diagnostic port (D_Port) available on the Brocade Gen 5 switches, administrators can quickly run automated diagnostic tests to assess the health of links and fabric components.
- Read diagnostic parameters (RDP) feature provides detailed port, media, and optics diagnostics to easily discover and diagnose link-related errors and degrading conditions on any N_Port-to-F_Port link.
- Single-pane-of-glass management across generations of QLogic FC adapters with QLogic QConvergeConsole (QCC).
- Deployment flexibility and integration with third-party management tools, including the VMware vCenter and Brocade Network Advisor.
- Support for 16 Gb, 8 Gb, and 4 Gb FC devices.
- Comprehensive virtualization capabilities with support for N_Port ID Virtualization (NPIV).
- A common driver model allows a single driver to support all QLogic HBAs on a given OS.
- Exceptional performance per watt and price/performance ratios.
- Backward compatibility with existing 4Gb and 8Gb FC infrastructure, leveraging existing SAN investments.
- Allow application of SAN best practices, tools, and processes with virtual server deployments.
- Ensure data availability and data integrity.
- Boot from SAN capability reduces the system management costs and increases uptime.
Technical specifications
The adapter has the following specifications:
- Host interface: PCIe 3.0 x8
- Ports: Dual-port adapter
- Link speed: Support for 16 Gb, 8 Gb and 4 Gb FC link speeds, which are automatically negotiated
- Data rate: 14.025 Gbps (1600 MBps), 8.5 Gbps (800 MBps), and 4.25 Gbps (400 MBps) autosensing (per port), with full duplex
- Performance: Up to 1,300,000 IOPS (up to 650,000 IOPS per port)
- Fibre Channel standards: FC-PI-5, FC-GS-2, FC-GS-3, SCSI-FCP, FCP-2, FC-TAPE
- Topology: Point-to-point and switched fabric
- Management software:
-
The QLogic unified management application, QLogic QConvergeConsole (QCC), provides single-pane-of-glass management across generations of QLogic FC adapters.
-
QLogic supports all major APIs for deployment flexibility and integration with third-party management tools, including the VMware vCenter and Brocade Network Advisor.
-
Server support
The adapter is supported in the the ThinkSystem compute nodes as indicated in the following table.
Table 2. Supported servers
Part number | Description |
x220 (7906)
|
x222 (7916)
|
x240 (8737, E5-2600)
|
x240 (8737, E5-2600 v2)
|
x240 (7162)
|
x240 M5 (9532)
|
x440 (7917)
|
x440 (7167)
|
x880/x480/x280 X6 (7903)
|
x280/x480/x880 X6 (7196)
|
SN550 (7X16)
|
SN850 (7X15)
|
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
7ZT7A00520 | ThinkSystem QLogic QML2692 Mezz 16Gb 2-Port Fibre Channel Adapter | N | N | N | N | N | N | N | N | N | N | Y | Y |
For the latest information about the expansion cards that are supported by each blade server type, see ServerProven at the following web address:
http://www.lenovo.com/us/en/serverproven/flexsystem.shtml
The following figure shows the location of the I/O expansion connectors.
Figure 2. Location of the I/O adapter slots in the Flex System SN550 Compute Node
I/O Module support
The adapters support the I/O module that is listed in the following table. One or two compatible switches must be installed in the corresponding I/O bays in the chassis. Installing two switches means that both ports of the adapter are enabled and connected to switch ports.
The following table shows the connections between adapters that are installed in the compute nodes to the switch bays in the chassis.
The connections between the adapters that are installed in the compute nodes to the switch bays in the chassis are shown in the following figure.
Figure 3. Logical layout of the interconnects between I/O adapters and I/O modules
Operating systems
The following table lists the supported operating systems.
Tip: This table is automatically generated based on data from Lenovo ServerProven.
1 Need out of box driver to support NPIV feature
Warranty
The adapter carries a one-year limited warranty. When installed in a supported server, the adapter assumes the server's base warranty and any Lenovo Services warranty upgrade.
Physical specifications
The dimensions and weight of the adapters are as follows:
- Width: 100 mm (3.9 in.)
- Depth: 80 mm (3.1 in.)
- Weight: 13 g (0.3 lb)
Shipping dimensions and weight (approximate):
- Height: 58 mm (2.3 in.)
- Width: 229 mm (9.0 in.)
- Depth: 208 mm (8.2 in.)
- Weight: 0.4 kg (0.89 lb)
Operating environment
The adapter is supported in the following environment:
- Temperature:
- Operating: 0 - 55 °C (32 - 131 °F)
- Storage: -20 - 70 °C (-4 - 185 °F)
- Relative humidity:
- Operating: 10 - 90% (non-condensing)
- Storage: 5 - 95% (non-condensing)
Agency approvals
The adapter conforms to the following regulations:
- AS/NZS CISPR22:2009+A1, Class A
- CSA 22.2, No. 60950-1-07 (2nd Edition)
- EN55022:2010, Class A
- EN55024:2010
- EU (CE Mark)
- FCC Rules, Part 15, Class A
- Industry Canada, ICES-003, Class A
- Japan VCCI, Class A
- Korea KC-RRA, Class A
- TUV EN60950-1:2006+A11+A1+A12 (2nd Edition)
- Taiwan BSMI, Class A
- UL60950-1 (2nd Edition)
Related publications and links
For more information, see the following resources:
- Flex System Information Center (User's Guides for servers and options)
http://flexsystem.lenovofiles.com/help/index.jsp - Marvell home page for Lenovo products
https://www.marvell.com/lenovo - Flex System Interoperability Guide
http://lenovopress.com/fsig - Lenovo Flex System Products and Technology
http://lenovopress.com/sg248255 - ServerProven for Flex System
http://www.lenovo.com/us/en/serverproven/flexsystem.shtml
Trademarks
Lenovo and the Lenovo logo are trademarks or registered trademarks of Lenovo in the United States, other countries, or both. A current list of Lenovo trademarks is available on the Web at https://www.lenovo.com/us/en/legal/copytrade/.
The following terms are trademarks of Lenovo in the United States, other countries, or both:
Lenovo®
ServerProven®
ThinkSystem®
The following terms are trademarks of other companies:
Xeon® is a trademark of Intel Corporation or its subsidiaries.
Linux® is the trademark of Linus Torvalds in the U.S. and other countries.
Microsoft®, Windows Server®, and Windows® are trademarks of Microsoft Corporation in the United States, other countries, or both.
Other company, product, or service names may be trademarks or service marks of others.
Configure and Buy
Full Change History
Changes in the October 9, 2018 update:
- Operating system support information is now listed as tables which are automatically generated from ServerProven data - Operating systems section
First published: 11 July 2017
Course Detail
Employees Only Content
The content in this document with a is only visible to employees who are logged in. Logon using your Lenovo ITcode and password via Lenovo single-signon (SSO).
The owner of the document has determined that this content is classified as Lenovo Internal and should not be normally be made available to people who are not employees or contractors. This includes partners, customers, and competitors. The reasons may vary and you should reach out to the authors of the document for clarification, if needed. Be cautious about sharing this content with others as it may contain sensitive information.
Any visitor to the Lenovo Press web site who is not logged on will not be able to see this employee-only content. This content is excluded from search engine indexes and will not appear in any search results.
For all users, including logged-in employees, this employee-only content does not appear in the PDF version of this document.
This functionality is cookie based. The web site will normally remember your login state between browser sessions, however, if you clear cookies at the end of a session or work in an Incognito/Private browser window, then you will need to log in each time.
If you have any questions about this feature of the Lenovo Press web, please email David Watts at dwatts@lenovo.com.