ThinkSystem Intel P4610 Mainstream NVMe PCIe 3.0 x4 SSDsProduct Guide
Author
Updated
5 Apr 2022Form Number
LP1032PDF size
12 pages, 202 KBAbstract
The Intel P4610 Mainstream NVMe SSDs are advanced data center SSDs optimized for mixed read-write performance, endurance, and strong data protection for Lenovo servers. They are designed for greater performance and endurance in a cost-effective design, and to support a broader set of workloads.
This product guide introduces the drives and describes their features and specifications, and provides compatibility information. This guide is intended for technical specialists, sales specialists, sales engineers, IT architects, and other IT professionals who want to learn more about the Intel P4610 SSDs and consider their use in IT solutions.
Change History
Changes in the March 5, 2022 update:
- The following 6.4TB drives have been reactivated and are available for configurations:
- ThinkSystem U.2 Intel P4610 6.4TB Mainstream NVMe PCIe3.0 x4 Hot Swap SSD, 4XB7A13938
- ThinkSystem 3.5" Intel P4610 6.4TB Mainstream NVMe PCIe3.0 x4 Hot Swap SSD, 4XB7A13946
Introduction
The ThinkSystem Intel P4610 Mainstream NVMe SSDs are advanced data center SSDs optimized for mixed read-write performance, endurance, and strong data protection for Lenovo servers. They are designed for greater performance and endurance in a cost-effective design, and to support a broader set of workloads.
The Intel P4610 SSDs are based on Intel-developed controller, firmware, and 64-layer TLC Intel 3D NAND technology. Rigorous qualification and compatibility testing by Lenovo ensures a highly reliable SSD.
Figure 1. ThinkSystem Intel P4610 Mainstream NVMe PCIe 3.0 x4 SSDs
Did You Know?
NVMe (Non-Volatile Memory Express) is a technology that overcomes SAS/SATA SSD performance limitations by optimizing hardware and software to take full advantage of flash technology. Intel Xeon processors efficiently transfer data in fewer clock cycles with the NVMe optimized software stack compared to the legacy Advance Host Controller Interface (AHCI) stack, thereby reducing latency and overhead. These SSDs connect directly to the processor via the PCIe bus, further reducing latency and TCO.
Part number information
The following table lists the ordering part numbers and feature codes for the SSDs.
Part number | Feature | Description |
---|---|---|
2.5-inch drives for ThinkSystem servers | ||
4XB7A13936 | B589 | ThinkSystem U.2 Intel P4610 1.6TB Mainstream NVMe PCIe3.0 x4 Hot Swap SSD |
4XB7A13937 | B58A | ThinkSystem U.2 Intel P4610 3.2TB Mainstream NVMe PCIe3.0 x4 Hot Swap SSD |
4XB7A13938 | B58B | ThinkSystem U.2 Intel P4610 6.4TB Mainstream NVMe PCIe3.0 x4 Hot Swap SSD |
2.5-inch drives for ThinkSystem SD650 (not hot-swap) | ||
4XB7A13947 | B62M | ThinkSystem SD650 U.2 Intel P4610 1.6TB Mainstream NVMe PCIe3.0 x4 SSD |
3.5-inch drives for ThinkSystem servers | ||
4XB7A13944 | B58C | ThinkSystem 3.5" Intel P4610 1.6TB Mainstream NVMe PCIe3.0 x4 Hot Swap SSD |
4XB7A13945 | B58D | ThinkSystem 3.5" Intel P4610 3.2TB Mainstream NVMe PCIe3.0 x4 Hot Swap SSD |
4XB7A13946 | B58E | ThinkSystem 3.5" Intel P4610 6.4TB Mainstream NVMe PCIe3.0 x4 Hot Swap SSD |
* The 7.68TB is available via special bid
The part numbers for the drives include the following items:
- One drive with a hot-swap tray attached
- Publication flyer
Features
Non-Volatile Memory Express (NVMe) is new PCIe 3.0 high performance SSD technology that provides high I/O throughput and low latency. NVMe interfaces remove SAS/SATA bottlenecks and unleash all of the capabilities of contemporary NAND flash memory. Each NVMe PCI SSD has direct PCIe 3.0 x4 connection, which provides at least 2x more bandwidth and 2x less latency than SATA/SAS-based SSD solutions. NVMe drives are also optimized for heavy multi-threaded workloads by using internal parallelism and many other improvements, such as enlarged I/O queues.
The P4610 drives provide performance, quality of service (QoS) and capacity improvements over the previous generation P4600 drives. With the P4610 compared to the P4600, applications can achieve up to 35% faster write rate and up to a 4x reduction in service time at a QoS metric of 99.99% availability for random access workloads.
The Intel P4610 NVMe drives have the following key characteristics:
- PCIe 3.0 connection for each NVMe drive
- Ultra-low I/O latency
- Suitable for mixed read-write workloads
- Available in capacities up to 7.68 TB
- Variable sector size and end-to-end data-path protection
- Enhanced power-loss data protection
- Thermal throttling and monitoring
- SMART health reporting
The key metric for solid state drives is their endurance (life expectancy). SSDs have a huge, but finite, number of program/erase (P/E) cycles, which determines how long the drives can perform write operations and thus their life expectancy. Performance SSDs have better endurance than Mainstream SSDs, which in turn have better endurance than Entry SSDs.
SSD write endurance is typically measured by the number of program/erase cycles that the drive can incur over its lifetime, which is listed as TBW in the device specification. The TBW value that is assigned to a solid-state device is the total bytes of written data that a drive can be guaranteed to complete. Reaching this limit does not cause the drive to immediately fail; the TBW simply denotes the maximum number of writes that can be guaranteed.
A solid-state device does not fail upon reaching the specified TBW, but at some point after surpassing the TBW value (and based on manufacturing variance margins), the drive reaches the end-of-life point, at which time the drive goes into read-only mode. Because of such behavior, careful planning must be done to use SSDs in the application environments to ensure that the TBW of the drive is not exceeded before the required life expectancy.
For example, the 3.2TB P4610 drive has an endurance of 21.8 PB of total bytes written (TBW). This means that for full operation over five years, write workload must be limited to no more than 11.9 TB of writes per day, which is equivalent to 3.7 full drive writes per day (DWPD). For the device to last three years, the drive write workload must be limited to no more than 19.9 TB of writes per day, which is equivalent to 6.2 full drive writes per day.
Technical specifications
The following table present technical specifications for the Intel P4610 drives.
Feature | 1.6 TB drive | 3.2 TB drive | 6.4 TB drive | 7.68 TB drive |
---|---|---|---|---|
Interface | PCIe 3.0 x4 | PCIe 3.0 x4 | PCIe 3.0 x4 | PCIe 3.0 x4 |
Capacity | 1.6 TB | 3.2 TB | 6.4 TB | 7.68 TB |
Endurance (total bytes written) |
12.25 PB | 21.85 PB | 36.54 PB | 44.25 PB |
Endurance (drive writes per day over 5 years) |
4.2 DWPD | 3.7 DWPD | 3.1 DWPD | 3.2 DWPD |
Data reliability | < 1 in 1017 bits read | < 1 in 1017 bits read | < 1 in 1017 bits read | < 1 in 1017 bits read |
MTBF, hours | 2,000,000 | 2,000,000 | 2,000,000 | 2,000,000 |
IOPS read (4 KB blocks) | 643,000 | 638,000 | 654,000 | 651,000 |
IOPS write (4 KB blocks) | 199,000 | 222,000 | 210,500 | 219,000 |
Sequential read rate | 3.20 GBps | 3.20 GBps | 3.20 GBps | 3.20 GBps |
Sequential write rate | 2.08 GBps | 3.05 GBps | 3.20 GBps | 3.20 GBps |
Read access latency random* | 77 µs | 77 µs | 77 µs | 77 µs |
Write access latency random* | 18 µs | 18 µs | 18 µs | 18 µs |
Shock, operating | 1,000 G (Max) at 0.5 ms | 1,000 G (Max) at 0.5 ms | 1,000 G (Max) at 0.5 ms | 1,000 G (Max) at 0.5 ms |
Vibration, max, operating | 2.17 GRMS (5-700 Hz) | 2.17 GRMS (5-700 Hz) | 2.17 GRMS (5-700 Hz) | 2.17 GRMS (5-700 Hz) |
Average power (Active Read / Active Write) | 10.2 / 13.3 W | 8.7 / 13.8 W | 9.3 / 14.6 W | 9.3 / 14.8 W |
* Latency measured using 4 KB transfer size with queue depth = 1 on a random workload.
Server support
The following tables list the ThinkSystem servers that are compatible.
Part Number | Description | Edge | 1S Intel V2 | 2S Intel V2 | AMD | Dense V2 | 4S V2 | 8S | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
SE350 (7Z46 / 7D1X) |
SE450 (7D8T) |
ST50 V2 (7D8K / 7D8J) |
ST250 V2 (7D8G / 7D8F) |
SR250 V2 (7D7R / 7D7Q) |
ST650 V2 (7Z75 / 7Z74) |
SR630 V2 (7Z70 / 7Z71) |
SR650 V2 (7Z72 / 7Z73) |
SR670 V2 (7Z22 / 7Z23) |
SR635 (7Y98 / 7Y99) |
SR655 (7Y00 / 7Z01) |
SR645 (7D2Y / 7D2X) |
SR665 (7D2W / 7D2V) |
SD630 V2 (7D1K) |
SD650 V2 (7D1M) |
SD650-N V2 (7D1N) |
SN550 V2 (7Z69) |
SR850 V2 (7D31 / 7D32) |
SR860 V2 (7Z59 / 7Z60) |
SR950 (7X11 / 7X12) |
||
2.5-inch drives for ThinkSystem servers | |||||||||||||||||||||
4XB7A13936 | ThinkSystem U.2 Intel P4610 1.6TB Mainstream NVMe PCIe3.0 x4 Hot Swap SSD | N | N | N | N | N | N | N | N | N | Y | Y | Y | Y | N | N | N | N | Y | Y | Y |
4XB7A13937 | ThinkSystem U.2 Intel P4610 3.2TB Mainstream NVMe PCIe3.0 x4 Hot Swap SSD | N | N | N | N | N | N | N | N | N | Y | Y | Y | Y | N | N | N | N | Y | Y | Y |
4XB7A13938 | ThinkSystem U.2 Intel P4610 6.4TB Mainstream NVMe PCIe3.0 x4 Hot Swap SSD | N | N | N | N | N | N | N | N | N | Y | Y | Y | Y | N | N | N | N | N | N | Y |
2.5-inch drives for ThinkSystem SD650 (not hot-swap) | |||||||||||||||||||||
4XB7A13947 | ThinkSystem SD650 U.2 Intel P4610 1.6TB Mainstream NVMe PCIe3.0 x4 SSD | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
3.5-inch drives for ThinkSystem servers | |||||||||||||||||||||
4XB7A13944 | ThinkSystem 3.5" Intel P4610 1.6TB Mainstream NVMe PCIe3.0 x4 Hot Swap SSD | N | N | N | N | N | N | N | N | N | N | Y | Y | Y | N | N | N | N | N | N | N |
4XB7A13945 | ThinkSystem 3.5" Intel P4610 3.2TB Mainstream NVMe PCIe3.0 x4 Hot Swap SSD | N | N | N | N | N | N | N | N | N | N | Y | Y | Y | N | N | N | N | N | N | N |
4XB7A13946 | ThinkSystem 3.5" Intel P4610 6.4TB Mainstream NVMe PCIe3.0 x4 Hot Swap SSD | N | N | N | N | N | N | N | N | N | N | Y | Y | Y | N | N | N | N | N | N | N |
Part Number | Description | 1S Intel V1 | 2S Intel V1 | Dense V1 | 4S V1 | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ST50 (7Y48 / 7Y50) |
ST250 (7Y45 / 7Y46) |
SR150 (7Y54) |
SR250 (7Y52 / 7Y51) |
ST550 (7X09 / 7X10) |
SR530 (7X07 / 7X08) |
SR550 (7X03 / 7X04) |
SR570 (7Y02 / 7Y03) |
SR590 (7X98 / 7X99) |
SR630 (7X01 / 7X02) |
SR650 (7X05 / 7X06) |
SR670 (7Y36 / 7Y37) |
SD530 (7X21) |
SD650 (7X58) |
SN550 (7X16) |
SN850 (7X15) |
SR850 (7X18 / 7X19) |
SR850P (7D2F / 2D2G) |
SR860 (7X69 / 7X70) |
||
2.5-inch drives for ThinkSystem servers | ||||||||||||||||||||
4XB7A13936 | ThinkSystem U.2 Intel P4610 1.6TB Mainstream NVMe PCIe3.0 x4 Hot Swap SSD | N | N | N | N | N | N | N | Y | Y | Y | Y | N | Y | N | Y | Y | Y | Y | Y |
4XB7A13937 | ThinkSystem U.2 Intel P4610 3.2TB Mainstream NVMe PCIe3.0 x4 Hot Swap SSD | N | N | N | N | N | N | N | Y | Y | Y | Y | N | Y | N | Y | Y | Y | Y | Y |
4XB7A13938 | ThinkSystem U.2 Intel P4610 6.4TB Mainstream NVMe PCIe3.0 x4 Hot Swap SSD | N | N | N | N | N | N | N | Y | Y | Y | Y | N | Y | N | Y | Y | Y | Y | N |
2.5-inch drives for ThinkSystem SD650 (not hot-swap) | ||||||||||||||||||||
4XB7A13947 | ThinkSystem SD650 U.2 Intel P4610 1.6TB Mainstream NVMe PCIe3.0 x4 SSD | N | N | N | N | N | N | N | N | N | N | N | N | N | Y | N | N | N | N | N |
3.5-inch drives for ThinkSystem servers | ||||||||||||||||||||
4XB7A13944 | ThinkSystem 3.5" Intel P4610 1.6TB Mainstream NVMe PCIe3.0 x4 Hot Swap SSD | N | N | N | N | N | N | N | N | N | Y | Y | N | N | N | N | N | N | N | N |
4XB7A13945 | ThinkSystem 3.5" Intel P4610 3.2TB Mainstream NVMe PCIe3.0 x4 Hot Swap SSD | N | N | N | N | N | N | N | N | N | Y | Y | N | N | N | N | N | N | N | N |
4XB7A13946 | ThinkSystem 3.5" Intel P4610 6.4TB Mainstream NVMe PCIe3.0 x4 Hot Swap SSD | N | N | N | N | N | N | N | N | N | Y | Y | N | N | N | N | N | N | N | N |
Operating system support
The drives support the following operating systems:
Tip: This table is automatically generated based on data from Lenovo ServerProven.
Operating systems | SR850 V2 |
SR860 V2 |
SR635 |
SR645 |
SR655 |
SR665 |
SD530 (Gen 2) |
SN550 (Gen 2) |
SN850 (Gen 2) |
SR570 (Gen 2) |
SR590 (Gen 2) |
SR630 (Gen 2) |
SR650 (Gen 2) |
SR850 (Gen 2) |
SR850P |
SR860 (Gen 2) |
SR950 (Gen 2) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Microsoft Windows Server 2012 R2 | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
Microsoft Windows Server 2016 | Y | Y | Y | Y | Y | Y | N | N | N | Y | Y | Y | Y | Y | Y | Y | Y |
Microsoft Windows Server 2019 | Y | Y | Y | Y | Y | Y | N | N | N | Y | Y | Y | Y | Y | Y | Y | Y |
Microsoft Windows Server 2022 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Microsoft Windows Server version 1709 | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
Microsoft Windows Server version 1803 | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
Red Hat Enterprise Linux 6.10 | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
Red Hat Enterprise Linux 6.9 | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
Red Hat Enterprise Linux 7.3 | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
Red Hat Enterprise Linux 7.4 | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
Red Hat Enterprise Linux 7.5 | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
Red Hat Enterprise Linux 7.6 | N | N | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Red Hat Enterprise Linux 7.7 | N | N | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Red Hat Enterprise Linux 7.8 | N | N | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Red Hat Enterprise Linux 7.9 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Red Hat Enterprise Linux 8.0 | N | N | Y | N | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Red Hat Enterprise Linux 8.1 | N | N | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Red Hat Enterprise Linux 8.2 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Red Hat Enterprise Linux 8.3 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Red Hat Enterprise Linux 8.4 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Red Hat Enterprise Linux 8.5 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Red Hat Enterprise Linux 8.6 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Red Hat Enterprise Linux 9.0 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
SUSE Linux Enterprise Server 11 SP4 | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
SUSE Linux Enterprise Server 12 SP2 | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
SUSE Linux Enterprise Server 12 SP2 with Xen | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
SUSE Linux Enterprise Server 12 SP3 | N | N | N | N | N | N | N | N | N | N | N | N | N | N | Y | N | N |
SUSE Linux Enterprise Server 12 SP3 with Xen | N | N | N | N | N | N | N | N | N | N | N | N | N | N | Y | N | N |
SUSE Linux Enterprise Server 12 SP4 | N | N | Y | N | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
SUSE Linux Enterprise Server 12 SP4 with Xen | N | N | Y | N | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
SUSE Linux Enterprise Server 12 SP5 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
SUSE Linux Enterprise Server 12 SP5 with Xen | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
SUSE Linux Enterprise Server 15 | N | N | N | N | N | N | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
SUSE Linux Enterprise Server 15 SP1 | N | N | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
SUSE Linux Enterprise Server 15 SP1 with Xen | N | N | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
SUSE Linux Enterprise Server 15 SP2 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
SUSE Linux Enterprise Server 15 SP2 with Xen | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
SUSE Linux Enterprise Server 15 SP3 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
SUSE Linux Enterprise Server 15 SP3 with Xen | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
SUSE Linux Enterprise Server 15 with Xen | N | N | N | N | N | N | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
VMware vSphere Hypervisor (ESXi) 6.5 | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
VMware vSphere Hypervisor (ESXi) 6.5 U3 | N | N | Y | N | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
VMware vSphere Hypervisor (ESXi) 6.7 | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
VMware vSphere Hypervisor (ESXi) 6.7 U2 | N | N | N | N | N | N | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
VMware vSphere Hypervisor (ESXi) 6.7 U3 | N | N | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
VMware vSphere Hypervisor (ESXi) 7.0 | N | N | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
VMware vSphere Hypervisor (ESXi) 7.0 U1 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
VMware vSphere Hypervisor (ESXi) 7.0 U2 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
VMware vSphere Hypervisor (ESXi) 7.0 U3 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Operating systems | SD530 (Gen 1) |
SN550 (Gen 1) |
SN850 (Gen 1) |
SR570 (Gen 1) |
SR590 (Gen 1) |
SR630 (Gen 1) |
SR650 (Gen 1) |
SR850 (Gen 1) |
SR860 (Gen 1) |
SR950 (Gen 1) |
---|---|---|---|---|---|---|---|---|---|---|
Microsoft Windows Server 2012 R2 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Microsoft Windows Server 2016 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Microsoft Windows Server 2019 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Microsoft Windows Server 2022 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Microsoft Windows Server version 1709 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Microsoft Windows Server version 1803 | Y | Y | N | N | N | Y | Y | Y | Y | Y |
Red Hat Enterprise Linux 6.10 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Red Hat Enterprise Linux 6.9 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Red Hat Enterprise Linux 7.3 | Y | Y | Y | N | N | Y | Y | Y | N | Y |
Red Hat Enterprise Linux 7.4 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Red Hat Enterprise Linux 7.5 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Red Hat Enterprise Linux 7.6 | Y | N | Y | Y | Y | Y | Y | Y | Y | Y |
Red Hat Enterprise Linux 7.7 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Red Hat Enterprise Linux 7.8 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Red Hat Enterprise Linux 7.9 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Red Hat Enterprise Linux 8.0 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Red Hat Enterprise Linux 8.1 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Red Hat Enterprise Linux 8.2 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Red Hat Enterprise Linux 8.3 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Red Hat Enterprise Linux 8.4 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Red Hat Enterprise Linux 8.5 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Red Hat Enterprise Linux 8.6 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Red Hat Enterprise Linux 9.0 | N | N | N | N | N | N | N | N | N | N |
SUSE Linux Enterprise Server 11 SP4 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
SUSE Linux Enterprise Server 12 SP2 | Y | N | Y | N | N | Y | Y | Y | N | Y |
SUSE Linux Enterprise Server 12 SP2 with Xen | Y | N | Y | N | N | Y | Y | Y | N | Y |
SUSE Linux Enterprise Server 12 SP3 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
SUSE Linux Enterprise Server 12 SP3 with Xen | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
SUSE Linux Enterprise Server 12 SP4 | Y | N | Y | Y | Y | Y | Y | Y | Y | Y |
SUSE Linux Enterprise Server 12 SP4 with Xen | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
SUSE Linux Enterprise Server 12 SP5 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
SUSE Linux Enterprise Server 12 SP5 with Xen | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
SUSE Linux Enterprise Server 15 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
SUSE Linux Enterprise Server 15 SP1 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
SUSE Linux Enterprise Server 15 SP1 with Xen | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
SUSE Linux Enterprise Server 15 SP2 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
SUSE Linux Enterprise Server 15 SP2 with Xen | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
SUSE Linux Enterprise Server 15 SP3 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
SUSE Linux Enterprise Server 15 SP3 with Xen | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
SUSE Linux Enterprise Server 15 with Xen | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
VMware vSphere Hypervisor (ESXi) 6.5 | Y | Y | Y | N | N | Y | Y | Y | N | Y |
VMware vSphere Hypervisor (ESXi) 6.5 U3 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
VMware vSphere Hypervisor (ESXi) 6.7 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
VMware vSphere Hypervisor (ESXi) 6.7 U2 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
VMware vSphere Hypervisor (ESXi) 6.7 U3 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
VMware vSphere Hypervisor (ESXi) 7.0 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
VMware vSphere Hypervisor (ESXi) 7.0 U1 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
VMware vSphere Hypervisor (ESXi) 7.0 U2 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
VMware vSphere Hypervisor (ESXi) 7.0 U3 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Warranty
The SSDs carry a 1-year, customer-replaceable unit (CRU) limited warranty. When installed in a supported Lenovo server, these drives assume the server’s base warranty and any warranty upgrade.
Solid State Memory cells have an intrinsic, finite number of program/erase cycles that each cell can incur. As a result, each solid state device has a maximum amount of program/erase cycles to which it can be subjected. The warranty for Lenovo solid state drives (SSDs) is limited to drives that have not reached the maximum guaranteed number of program/erase cycles, as documented in the Official Published Specifications for the SSD product. A drive that reaches this limit may fail to operate according to its Specifications.
Physical specifications
The Intel P4610 drives have the following physical dimensions and weight (without tray):
- Height: 15 mm (0.6 in.)
- Width: 70 mm (2.8 in.)
- Depth: 100 mm (4.0 in.)
- Weight: up to 139 g (4.9 oz)
Operating environment
The Intel P4610 drives are supported in the following environment:
- Temperature (operational): 0 to 70 °C (32 to 158 °F) at 0 to 3,048 m (0 to 10,000 ft)
- Relative humidity: 5 to 90% (non-condensing)
- Maximum altitude (operational): 3,048 m (10,000 ft)
- Shock: 1,000 G (Max) at 0.5 ms
- Vibration: 2.17 GRMS (5-700 Hz)
Agency approvals
The Intel P4610 drives conform to the following regulations:
- FCC Title 47, Part 15B, Class B
- CA/CSA-CEI/IEC CISPR 22:02
- EN 55024: 1998
- EN 55022: 2006
- EN-60950-1 2nd Edition
- UL/CSA EN-60950-1 2nd Edition
- Low Voltage Directive 2006/95/EC
- C-Tick: AS/NZS3584
- BSMI: CNS 13438
- KCC Article 11.1
- RoHS DIRECTIVE 2011/65/EU
- WEEE Directive 2002/96/EC
Related publications and links
For more information, see the following documents:
- Storage Options for ThinkSystem Servers
https://lenovopress.com/lp0761-storage-options-for-thinksystem-servers - ServerProven
http://www.lenovo.com/us/en/serverproven - Intel P4610 specifications
https://www.intel.com/content/www/us/en/products/memory-storage/solid-state-drives/data-center-ssds/dc-p4610-series.html - Intel P4610 product brief
https://www.intel.com/content/www/us/en/products/docs/memory-storage/solid-state-drives/data-center-ssds/dc-p4610-series-brief.html
Trademarks
Lenovo and the Lenovo logo are trademarks or registered trademarks of Lenovo in the United States, other countries, or both. A current list of Lenovo trademarks is available on the Web at https://www.lenovo.com/us/en/legal/copytrade/.
The following terms are trademarks of Lenovo in the United States, other countries, or both:
Lenovo®
ServerProven®
ThinkSystem
The following terms are trademarks of other companies:
Intel® and Xeon® are trademarks of Intel Corporation or its subsidiaries.
Linux® is the trademark of Linus Torvalds in the U.S. and other countries.
Microsoft®, Windows Server®, and Windows® are trademarks of Microsoft Corporation in the United States, other countries, or both.
Other company, product, or service names may be trademarks or service marks of others.
Configure and Buy
Full Change History
Changes in the March 5, 2022 update:
- The following 6.4TB drives have been reactivated and are available for configurations:
- ThinkSystem U.2 Intel P4610 6.4TB Mainstream NVMe PCIe3.0 x4 Hot Swap SSD, 4XB7A13938
- ThinkSystem 3.5" Intel P4610 6.4TB Mainstream NVMe PCIe3.0 x4 Hot Swap SSD, 4XB7A13946
Changes in the November 23, 2021 update:
- The following 1.6TB drives have been reactivated and are available for configurations:
- ThinkSystem U.2 Intel P4610 1.6TB Mainstream NVMe PCIe3.0 x4 Hot Swap SSD, 4XB7A13936
- ThinkSystem 3.5" Intel P4610 1.6TB Mainstream NVMe PCIe3.0 x4 Hot Swap SSD, 4XB7A13944
Changes in the June 29, 2021 update:
- All drives listed in this product guide are now withdrawn from marketing.
Changes in the February 27, 2021 update:
- The server support tables are now automatically updated - Server support section
Changes in the October 13, 2020 update:
- Added the SR850 V2 and SR860 V2 servers - Server support section
Changes in the September 8, 2020 update:
- The SR645 and SR665 now support P4610 drives - Server support section
Changes in the May 5, 2020 update:
- Added SR645 and SR665 to the server support table - Server support section (no support)
Changes in the January 7, 2020 update:
- Added SR850P to the server support table - Server support section
Changes in the December 10, 2019 update:
- The SR635 and SR655 now support the 2.5" drives - Server support section
- The SR655 also supports the 3.5" drives
Changes in the September 12, 2019 update:
- Added SE350, SR635 and SR655 to the server table - Server support section
Changes in the April 16, 2019 update:
- New 1.6TB drive option, 4XB7A13947, for the ThinkSystem SD650 server - Part number information section
Changes in the March 18, 2019 update:
- Operating system support information is now listed as a set of tables which are automatically generated from ServerProven data - Operating system support section
First published: 11 December 2018