skip to main content

Lenovo ThinkSystem SR250 Server (E-2200)

Product Guide (withdrawn product)

Home
Top

Abstract

Lenovo ThinkSystem SR250 is an affordable, single-socket 1U rack server for small and medium businesses that need optimized performance and flexibility for future growth, along with enterprise-class reliability, management, and security.

The SR250 server offers a wide range of processors — from Intel Celeron to Intel Xeon E Series. With support for a memory capacity of up to 128 GB and internal storage of up to 32 TB, the SR250 server is an ideal choice for small- to medium-sized business, workgroups, distributed locations, and web-scale workloads.

This product guide provides essential technical and pre-sales information on the SR250 server, its key features and specifications, components and options, and configuration guidelines.

This guide is intended for technical specialists, sales specialists, sales engineers, IT architects, and other IT professionals who want to learn more about the SR250 server and consider its use in IT solutions.

Withdrawn: The ThinkSystem SR250 is now withdrawn from marketing. The follow-on server is the ThinkSystem SR250 V2. See the SR250 V2 product guide for details, https://lenovopress.lenovo.com/lp1549-thinksystem-sr250-v2

Change History

Changes in the April 24, 2023 update:

Introduction

Lenovo ThinkSystem SR250 is an affordable, single-socket 1U rack server for small and medium businesses that need optimized performance and flexibility for future growth, along with enterprise-class reliability, management, and security.

The SR250 server offers a wide range of processors — from Intel Celeron to Intel Xeon E Series. With support for a memory capacity of up to 128 GB and internal storage of up to 32 TB, the SR250 server is an ideal choice for small- to medium-sized business, workgroups, distributed locations, and web-scale workloads.

Flexible and scalable internal storage configurations include up to ten 2.5-inch or four 3.5-inch drives with affordable software RAID or advanced hardware RAID protection and a wide selection of drive sizes and types, including NVMe PCIe SSDs, SAS/SATA SSDs, and SAS/SATA HDDs. Also, it features integrated dual-port 1 Gb Ethernet NIC and additional PCIe expansion slots for hardware RAID protection, network scalability, and external storage connectivity.

The next-generation Lenovo XClarity Controller, which is built into the SR250 server, provides advanced service processor control, monitoring, and alerting functions.

The following figure shows the Lenovo ThinkSystem SR250.

Lenovo ThinkSystem SR250
Figure 1 Lenovo ThinkSystem SR250

Did you know?

The SR250 server offers enterprise-class reliability features such as error correcting code (ECC), hot-swap components, and advanced RAID protection with flexible storage options at an affordable price.

The SR250 server has a mere 19.6-inch (498 mm) deep chassis, helping customers reduce their business footprint.

The SR250 server offers performance, energy efficiency, and serviceability features, such as NVMe PCIe SSDs, 80 PLUS Gold and Platinum certified power supplies, and easy access to upgrades and serviceable parts (such as memory DIMMs and adapter cards), which is not typically found in the single-socket value servers.

The SR250 server offers easy-to-use, enterprise-class manageability to monitor server availability and perform remote management with the built-in Lenovo XClarity Controller.

Key features

The SR250 server is a compact, cost-effective, single-processor 1U rack server that has been optimized to provide enterprise-class features to small-to-medium-sized businesses, retail stores, or distributed enterprises.

Scalability and performance

The SR250 server offers numerous features to boost performance, improve scalability, and reduce costs:

  • Improves productivity by offering superior system performance with the Intel Xeon E Series processors with up to 6 cores, up to 16 MB of last level cache (LLC), up to 2666 MHz memory speeds, and up to 8 GT/s bus speed.
    • Choice of processors with up to 6 cores and up to 16 threads to enable the effective use of multithreaded applications.
    • Intelligent and adaptive system performance with energy efficient Intel Turbo Boost 2.0 Technology allows CPU cores to run at maximum speeds during peak workloads by temporarily going beyond processor thermal design power (TDP).
    • Intel Hyper-Threading Technology boosts performance for multithreaded applications by enabling simultaneous multithreading within each processor core, up to two threads per core.
    • Intel Virtualization Technology integrates hardware-level virtualization hooks that allow operating system vendors to better utilize the hardware for virtualization workloads.
    • Intel Advanced Vector Extensions (AVX) enable acceleration of enterprise-class and high performance computing (HPC) workloads.
  • Provides memory speed, availability, and capacity of up to 128 GB memory with up to four 2666 MHz DDR4 ECC UDIMMs.
  • Offers flexible and scalable internal storage in a 1U rack form factor with up to 10x 2.5-inch drives for performance-optimized configurations or up to 4x 3.5-inch drives for capacity-optimized configurations, providing a wide selection of SAS/SATA HDD/SSD and PCIe NVMe SSD types and capacities.
  • Provides I/O scalability with the onboard LOM interface and up to three PCI Express (PCIe) 3.0 I/O expansion slots in a 1U rack form factor.
  • Reduces I/O latency and increases overall system performance with Intel Integrated I/O Technology that embeds the PCI Express 3.0 controller with 16 lanes into the processors.

Availability and serviceability

The SR250 server provides many features to simplify serviceability and increase system uptime:

  • Offers ECC protection which provides error correction not available in PC-class "servers" that use parity memory.
  • Provides easy access to upgrades and serviceable parts (such as memory DIMMs and adapter cards) with tool-less cover removal.
  • Offers data protection and greater system uptime with a choice of affordable onboard SATA RAID or advanced hardware RAID redundancy, along with hot-swap drives (select models).
  • Provides availability for business-critical applications with redundant hot-swap power supplies (select models).
  • Allows preventive actions in advance of possible failure, thereby increasing server uptime and application availability with Proactive Platform Alerts (including PFA and SMART alerts) for memory, internal storage (SAS/SATA HDDs and SSDs, NVMe SSDs, M.2 SSDs), RAID controllers, and server ambient and sub-component temperatures.
  • Continuously monitors system parameters, triggers alerts, and performs recovery actions in case of failure to minimize downtime with Built-in XClarity Controller (XCC).
  • Provides quick access to system status, firmware, network, health, and alerts information via Virtual Operator Panel from the XClarity Mobile App running on the Android or iOS mobile device that is connected to the front USB port with XClarity Controller access.
  • Speeds up troubleshooting tasks to reduce service time with diagnostics built into the XClarity Provisioning Manager.

Manageability and security

Powerful systems management features simplify local and remote management of the SR250 server and deliver enterprise-class data protection:

  • Provides advanced service processor control, monitoring, and alerting functions with XClarity Controller, a next generation service processor.
  • Improves Unified Extensible Firmware Interface (UEFI) system setup, configuration, updates, simplified error handling, and operating system deployment with the embedded XClarity Provisioning Manager.
  • Offers XClarity Essentials software tools that can help customers set up, use, and maintain the server.
  • Increases uptime, reduces costs, and improves productivity through advanced server management capabilities with Lenovo XClarity Administrator that provides comprehensive hardware management.
  • Provides on-the-go monitoring and management of devices in XClarity Administrator from anywhere with the Lenovo XClarity mobile app, which can help improve efficiency and reduce downtime risks.
  • Centralizes infrastructure resource management with Lenovo XClarity Integrators for VMware vCenter and Microsoft System Center, extending XClarity Administrator features to virtualization management software tools and enabling users to deploy and manage infrastructure end-to-end.
  • Offers advanced cryptographic functionality (such as digital signatures and remote attestation) with an integrated Trusted Platform Module (TPM) or optional Nationz TPM (available only in PRC).
  • Establishes a solid security foundation for workloads by delivering firmware that is securely built, tested, digitally signed, and verified prior to execution.
  • Offers enterprise-class data protection with advanced RAID and optional self-encrypting drives.
  • Provides faster, stronger encryption with industry-standard AES NI support.
  • Helps prevent certain classes of malicious buffer overflow attacks with Intel Execute Disable Bit functionality, when combined with a supporting operating system.
  • Enhances security through hardware-based resistance to malicious software attacks with Intel Trusted Execution Technology (Xeon E Series processors only), allowing an application to run in its own isolated space, protected from all other software running on a system.
  • Helps prevent unauthorized software from running on the server by protecting against boot block-level malicious software with Intel Boot Guard technology.
  • Protects application code and data from disclosure or modification with Intel Software Guard Extensions (SGX), enabling high-assurance security use cases, such as blockchain, identity and records privacy, secure browsing, and digital rights management (DRM).

Energy efficiency

The SR250 server offers the following energy-efficiency features to save energy, reduce operational costs, increase energy availability, and contribute to the green environment:

  • Delivers optimized compute power per watt, featuring 80 PLUS Gold (fixed) and Platinum (hot-swap) AC power supplies.
  • Reduces power drawn with Intel Intelligent Power Capability that powers individual processor elements on and off as needed.
  • Helps reduce power consumption with variable speed fans.
  • Helps achieve lower heat output and reduced cooling needs with Lenovo XClarity Energy Manager that provides advanced data center power notification, analysis, and policy-based management.

Components and connectors

The following figure shows the front of the SR250 server with four 3.5-inch drive bays.

Front view of the SR250: 4x 3.5-inch drive bays
Figure 2. Front view of the SR250: 4x 3.5-inch drive bays

The following figure shows the front of the SR250 server with eight 2.5-inch drive bays.

Front view of the SR250: 8x 2.5-inch drive bays
Figure 3. Front view of the SR250: 8x 2.5-inch drive bays

The following figure shows the front of the SR250 server with ten 2.5-inch drive bays.

Front view of the SR250: 10x 2.5-inch drive bays
Figure 4. Front view of the SR250: 10x 2.5-inch drive bays

The front of the SR250 server includes the following components:

  • Drive bays:
    • 4x 3.5-inch (Large Form Factor [LFF]) SATA simple-swap; or
    • 4x 3.5-inch SAS/SATA hot-swap; or
    • 8x 2.5-inch (Small Form Factor [SFF]) SAS/SATA hot-swap; or
    • 10x 2.5-inch hot-swap drive bays:
      • 10x SAS/SATA
      • 8x SAS/SATA and 2x NVMe PCIe
  • One VGA port (optional)
  • One USB 2.0 port with XClarity Controller access
  • One USB 3.1 Gen 1 port
  • A Power button
  • Status LEDs

The following figure shows the rear of the SR250 server.

Rear view of the SR250
Figure 5. Rear view of the SR250

The rear of the SR250 server includes the following components:

  • Up to two PCIe expansion slots (depending on the riser cards selected)
  • One 1 GbE port for XClarity Controller
  • One RS-232 serial port
  • One VGA port
  • Two 1 GbE data network ports
  • Two USB 3.1 Gen 2 ports
  • Power supplies
    • Up to two hot-swap power supplies; or
    • One fixed power supply

The following figure shows the locations of key components inside the SR250 server.

Internal view of the SR250
Figure 6. Internal view of the SR250

The SR250 server includes the following internal components:

  • One processor
  • Four DIMM slots
  • Up to three PCIe 3.0 slots:
    • Slot 1: PCIe 3.0 x8 (not present if the Slot 2 is PCIe x16)
    • Slot 2: PCIe 3.0 x8 or x16
    • Slot 3: PCIe 3.0 x4 (only supports a controller for internal storage)
  • Eight onboard SATA ports:
    • One Mini-SAS HD connector (4x SATA x1 ports)
    • Four SATA connectors (each connector provides the SATA x1 port)
  • One TCM/TPM connector (supports Nationz TPM available in PRC only)
  • Drive backplanes:
    • 4x LFF SATA simple-swap bracket; or
    • 4x LFF SAS/SATA hot-swap; or
    • 8x SFF SAS/SATA hot-swap; or
    • 8x SFF SAS/SATA and 2x SFF AnyBay hot-swap
  • Four non-hot-swap system fans
  • One M.2 connector

Standard specifications

The following table lists the system specifications for the SR250 server.

Table 1. SR250 system specifications
Attribute Specification
Form factor 1U rack-mount.
Processor One Intel Xeon E, Core i3, Pentium Gold, or Celeron processor.
Chipset Intel C246.
Memory 4 DIMM sockets (two memory channels with two DIMMs per channel). Support for ECC UDIMMs. Memory speed up to 2666 MHz.
Memory capacity
  • Xeon E Series: Up to 128 GB (4x 32 GB UDIMMs).
  • Core i3, Pentium Gold, Celeron G Series: Up to 64 GB (4x 16 GB UDIMMs).
Memory protection Error correction code (ECC).
Drive bays
  • 4 LFF (3.5-inch) SATA Simple Swap drive bays.
  • 4 LFF (3.5-inch) SAS/SATA hot-swap drive bays.
  • 8 SFF (2.5-inch) SAS/SATA hot-swap drive bays.
  • 10 SFF (2.5-inch) hot-swap drive bays:
    • 10x 2.5" SAS/SATA.
    • 8x 2.5" SAS/SATA & 2x 2.5" NVMe PCIe.
Internal storage capacity
  • 2.5-inch drives:
    • 76.8TB using 10x 7.68TB 2.5-inch SAS/SATA SSDs
    • 3.84TB using 2x 1.92TB 2.5-inch NVMe SSDs
    • 24TB using 10x 2.4TB 2.5-inch HDDs
  • 3.5-inch drives:
    • 80TB using 4x 20TB 3.5-inch HDDs
    • 15.36TB using 4x 3.84TB 3.5-inch SAS/SATA SSDs
  • Intermix of SAS and SATA is supported
Storage controller
  • Onboard 6 Gbps SATA:
    • AHCI non-RAID.
    • RAID 0/1/10/5 with Intel RSTe.
  • 12 Gbps SAS/6 Gbps SATA RAID:
    • RAID 0/1/10/5/50 with RAID 530-8i or RAID 730-8i 1GB Cache.
    • RAID 0/1/10/5/50/6/60 with RAID 730-8i 2GB Flash, RAID 930-8i 2GB Flash, or RAID 930-16i 4GB Flash.
  • 12 Gbps SAS/6 Gbps SATA non-RAID: 430-8i or 16i HBA.
  • NVMe PCIe non-RAID: 1610-4P NVMe Switch Adapter.
Optical drive bays None. Support for an external USB DVD RW Optical Disk Drive (See Optical drives).
Network interfaces 2x Onboard 10/100/1000 Mb Ethernet RJ-45 ports (BCM5720 NIC).
I/O expansion slots Up to three slots. Slot 3 is the fixed slot on the system planar, and the remaining slots depend on the riser cards installed. The slots are as follows:
  • Slot 1: PCIe 3.0 x8; low profile (not present if the Slot 2 is x16)
  • Slot 2: PCIe 3.0 x8 (x16 physical connector) or x16; full-height, half-length
  • Slot 3: PCIe 3.0 x4 (supports an internal storage controller)
Ports
  • Front: 1x VGA port (optional), 1x USB 3.1 Gen 1 port, and 1x USB 2.0 port with XClarity Controller access.
  • Rear: 1x VGA port, 2x USB 3.1 Gen 2 ports, 1x DB-9 serial port, and 1x RJ-45 10/100/1000 Mb Ethernet systems management port.
Cooling Four non-hot-swap system fans.
Power supply One fixed 300 W Gold, or up to two redundant hot-swap 450 W Platinum AC power supplies.
Video Matrox G200 with 16 MB memory integrated into the XClarity Controller. Maximum resolution is 1920x1200 at 60 Hz with 32 bits per pixel.
Hot-swap parts Drives (select models) and power supplies (select models).
Systems management XClarity Controller (XCC) Standard, Advanced, or Enterprise (Pilot 4 chip), proactive platform alerts, XClarity Provisioning Manager, XClarity Essentials, XClarity Administrator, XClarity Integrators for VMware vCenter and Microsoft System Center, XClarity Energy Manager, Capacity Planner.
Security features Power-on password, administrator's password, secure firmware updates, Trusted Platform Module (TPM) 1.2 or 2.0 (configurable UEFI setting). Optional lockable front bezel. Optional Nationz TPM (available only in PRC).
Operating systems Microsoft Windows Server, Red Hat Enterprise Linux, SUSE Linux Enterprise Server, VMware ESXi. See the Operating systems section for specifics.
Warranty One-year (7Y52) or three-year (7Y51, 7Y72, and 7Y73) customer-replaceable unit (CRU) and onsite limited warranty with 9x5 Next Business Day Parts Delivered.
Service and support Optional service upgrades are available through Lenovo Services: 2-hour or 4-hour response time, 6-hour or 24-hour committed service repair (select areas), warranty extension up to 5 years, 1-year or 2-year post-warranty extensions, Premier Support, YourDrive YourData, Enterprise Software Support, and Basic Hardware Installation Services.
Dimensions Width: 435 mm (17.1 in.), height: 43 mm (1.7 in.), depth: 545 mm (21.5 in.). See Physical specifications for details.
Weight Base configuration: 9.1 kg (20.1 lb), maximum: 12.3 kg (27.1 lb)

Models

ThinkSystem SR250 models can be configured by using the Lenovo Data Center Solution Configurator (DCSC).

Configure-to-order (CTO) models are used to create models with factory-integrated server customizations. For CTO models, two types of base CTO models are available for the SR250 as listed in the columns in the following table:

  • General purpose base CTO models are for general business (non-HPC) and is selectable by choosing General Purpose mode in DCSC.
  • AI and HPC base models are intended for Artificial Intelligence (AI) and High Performance Computing (HPC) configurations and solutions are enabled using the AI & HPC Hardware - ThinkSystem Hardware mode in DCSC. These configurations, along with Lenovo EveryScale Solutions, can also be built using System x and Cluster Solutions Configurator (x-config). Tip: Some HPC and AI models are not listed in DCSC and can only be configured in x-config.

Preconfigured server models may also be available for the SR250, however these are region-specific; that is, each region may define their own server models, and not all server models are available in every region.

The following table lists the base CTO models of the ThinkSystem SR250 server.

Table 2. Base CTO models
Machine Type/Model
General purpose
Machine Type/Model
for AI and HPC
Description
7Y51CTO1WW 7Y51CTOLWW ThinkSystem SR250 – 3-year warranty
7Y52CTO1WW 7Y52CTOLWW ThinkSystem SR250 – 1-year warranty

For customers in India, additional machine types are available as listed in the following table.

Table 3. CTO base models for India
Description Machine Type/Model
ThinkSystem SR250 India with RDN PSU (3-Year Warranty) 7Y72CTO1WW
ThinkSystem SR250 India with Fixed PSU (3-Year Warranty) 7Y73CTO1WW

The following table lists the base chassis for CTO models of the SR250 server.

Table 4. Base chassis for CTO models
Feature code Description
B403 ThinkSystem SR250/SR150 4x3.5" Chassis
B404 ThinkSystem SR250 2.5" Chassis

All models of the SR250 server are shipped with the Electronic Publications Flyer.

Models table conventions: The model tables shown in this section use the following conventions:

  • Drive bays:
    • If the number is shown as "x", it represents the quantity of the SAS/SATA drive bays.
    • If the number is shown as "x+y", it represents the quantity of the SAS/SATA + NVMe drive bays.
  • XClarity Controller: "S" = Standard, "A" = Advanced, "E" = Enterprise. 
  • Front VGA port: "Y" = Included; "N" = Not included, optional.
  • Tool-less 4-Post Rail Kit: "Y" = Included; "N" = Not included, optional.
  • Power cord:
    • "R1" = 1.5 m C13-C14 rack power cable.
    • "R2" = 2.8 m C13-C14 rack power cable.
    • "L2" = 2.8 m line cord.
    • "N" = Not included; see Power supplies and cables for the ordering information.

The following tables list the models of the SR250 server for the following regions:

Table 5. SR250 server models (3-year warranty): North America
Model
number
Intel
processor*
Memory
UDIMM
(4 max)
Storage
controller
Drive
bays
(std /
max)
Drives Eth.
LOM
I/O slots Power
supply^
XClarity Controller
Front VGA port
Tool-less Rail Kit
Power cord
Relationship models - North America
7Y51A04UNA 1x E-2224 4C
71W 3.4GHz
1x 8GB
(1Rx8)
1x SATA
AHCI
4 / 4
HS LFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 300W
Fixed
E Y Y R2
7Y51A054NA 1x E-2224 4C
71W 3.4GHz
1x 8GB
(1Rx8)
1x SATA
RAID
4 / 4
HS LFF
2x 1TB
SATA HDD†
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 450W
HS
E Y Y R2
7Y51A04RNA 1x E-2236 6C
80W 3.4GHz
1x 8GB
(1Rx8)
1x SATA
AHCI
4 / 4
HS LFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 450W
HS
E Y Y R2
7Y51A051NA 1x E-2236 6C
80W 3.4GHz
1x 8GB
(1Rx8)
1x SATA
RAID
4 / 4
SS LFF
2x 2TB
SATA HDD‡
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 450W
HS
E Y Y R2
7Y51A050NA 1x E-2288G 8C
95W 3.7GHz
1x 8GB
(1Rx8)
1x SATA
AHCI
8 / 10
HS SFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 450W
HS
E Y Y R2
7Y51A053NA 1x E-2288G 8C
95W 3.7GHz
1x 16GB
(2Rx4)
1x RAID
530-8i
8 / 10
HS SFF
2x 480GB
S4510 SSD‡
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 450W
HS
E Y Y R2

* Processor details: Processor quantity and model, cores, thermal design power (TDP), and core speed.
^ The server supports one fixed power supply or up to two hot-swap (HS) power supplies.
† Configured in a RAID-1 drive group; ships with the Windows Server 2019 Essentials - English factory preload.
‡ Configured in a RAID-1 drive group; ships with the Windows Server 2019 Standard (16 core) - English factory preload.

Table 6. SR250 server models (3-year warranty): Brazil
Model
number
Intel
processor*
Memory
UDIMM
(4 max)
Storage
controller
Drive
bays
(std /
max)
Drives Eth.
LOM
I/O slots Power
supply^
XClarity Controller
Front VGA port
Tool-less Rail Kit
Power cord
TopSeller models - Brazil
7Y511000BR 1x E-2224 4C
71W 3.4GHz
1x 16GB
(2Rx8)
1x SATA
AHCI
4 / 4
SS LFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 450W
HS
S N N L2

* Processor details: Processor quantity and model, cores, thermal design power (TDP), and core speed.
^ The server supports one fixed power supply or up to two hot-swap (HS) power supplies.

Table 7. SR250 server models: Latin America (except Brazil)
Model
number
Intel
processor*
Memory
UDIMM
(4 max)
Storage
controller
Drive
bays
(std /
max)
Drives Eth.
LOM
I/O slots Power
supply^
XClarity Controller
Front VGA port
Tool-less Rail Kit
Power cord
TopSeller models (3-year warranty) - Latin America (except Brazil)
7Y511002LA 1x E-2224 4C
71W 3.4GHz
1x 16GB
(2Rx8)
1x SATA
RAID
4 / 4
HS LFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 300W
Fixed
S Y Y R2
7Y511003LA 1x E-2224 4C
71W 3.4GHz
1x 16GB
(2Rx8)
1x SATA
RAID
4 / 4
HS LFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 450W
HS
S Y Y R2
7Y51A07RLA 1x E-2224G 4C
71W 3.5GHz
1x 16GB
(2Rx8)
1x RAID
730-8i 2GB
8 / 10
HS SFF
2x 480GB
PM883
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 450W
HS
S Y Y R2
7Y51A07ULA 1x E-2226G 6C
80W 3.4GHz
1x 16GB
(2Rx8)
1x RAID
730-8i 2GB
8 / 10
HS SFF
2x 2TB
SATA HDD
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 450W
HS
S Y Y R2
7Y51A084LA 1x E-2288G 8C
95W 3.7GHz
1x 32GB
(2Rx8)
1x SATA
AHCI
8 / 10
HS SFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 450W
HS
S Y Y R2
Relationship models (3-year warranty) - Latin America (except Brazil)
7Y511004LA 1x E-2226G 6C
80W 3.4GHz
1x 16GB
(2Rx8)
1x SATA
RAID
4 / 4
HS LFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 450W
HS
S Y Y R1
TopSeller models (1-year warranty) - Latin America (except Brazil)
7Y521003LA 1x E-2224 4C
71W 3.4GHz
1x 16GB
(2Rx8)
1x SATA
RAID
4 / 4
HS LFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 300W
Fixed
S Y Y R2
7Y521004LA 1x E-2224 4C
71W 3.4GHz
1x 16GB
(2Rx8)
1x SATA
RAID
4 / 4
HS LFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 450W
HS
S Y Y R2
Relationship models (1-year warranty) - Latin America (except Brazil)
7Y52A01TLA 1x E-2224 4C 71W 3.4GHz 1x 16GB
(2Rx8)
1x RAID 530-8i 4 / 4
HS LFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 450W
HS
S Y Y R2
7Y52A01ULA 1x E-2224 4C 71W 3.4GHz 1x 16GB
(2Rx8)
1x RAID 530-8i 8 / 10
HS SFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 450W
HS
S Y Y R2

* Processor details: Processor quantity and model, cores, thermal design power (TDP), and core speed.
^ The server supports one fixed power supply or up to two hot-swap (HS) power supplies.

Table 8. SR250 server models: EMEA
Model
number
Intel
processor*
Memory
UDIMM
(4 max)
Storage
controller
Drive
bays
(std /
max)
Drives Eth.
LOM
I/O slots Power
supply^
XClarity Controller
Front VGA port
Tool-less Rail Kit
Power cord
Relationship models (3-year warranty) - EMEA
7Y51A077EA 1x E-2224 4C
71W 3.4GHz
1x 8GB
(1Rx8)
1x SATA
AHCI
4 / 4
SS LFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 300W
Fixed
S N Y R2
7Y51A075EA 1x E-2224 4C
71W 3.4GHz
1x 8GB
(1Rx8)
1x SATA
RAID
4 / 4
SS LFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 300W
Fixed
S N Y R2
7Y51A07GEA 1x E-2224 4C
71W 3.4GHz
1x 8GB
(1Rx8)
1x SATA
RAID
4 / 4
HS LFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 300W
Fixed
S N Y R2
7Y51A078EA 1x E-2224 4C
71W 3.4GHz
1x 8GB
(1Rx8)
1x SATA
RAID
4 / 4
HS LFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 450W
HS
S N Y R2
7Y51A07KEA 1x E-2224 4C
71W 3.4GHz
1x 16GB
(2Rx4)
1x SATA
RAID
8 / 10
HS SFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 450W
HS
S N Y R2
7Y51A07AEA 1x E-2234 4C
71W 3.6GHz
1x 16GB
(2Rx4)
1x SATA
AHCI
4 / 4
SS LFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 300W
Fixed
S N Y R2
7Y51A07BEA 1x E-2234 4C
71W 3.6GHz
1x 8GB
(1Rx8)
1x SATA
RAID
4 / 4
HS LFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 450W
HS
S N Y R2
7Y51A076EA 1x E-2244G 4C
71W 3.8GHz
1x 16GB
(2Rx4)
1x SATA
RAID
4 / 4
HS LFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 450W
HS
S N Y R2
7Y51A07FEA 1x E-2246G 6C
80W 3.6GHz
1x 16GB
(2Rx4)
1x SATA
RAID
8 / 10
HS SFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 450W
HS
S N Y R2
7Y51A079EA 1x E-2246G 6C
80W 3.6GHz
1x 16GB
(2Rx4)
1x SATA
RAID
8 / 10
HS SFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 450W
HS
S N Y R2
7Y51A07EEA 1x E-2276G 6C
80W 3.8GHz
1x 16GB
(2Rx4)
1x SATA
RAID
8 / 10
HS SFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 450W
HS
S N Y R2
7Y51A07DEA 1x E-2276G 6C
80W 3.8GHz
1x 16GB
(2Rx4)
1x SATA
RAID
8 / 10
HS SFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 450W
HS
S N Y R2
7Y51A07CEA 1x E-2278G 8C
80W 3.4GHz
1x 16GB
(2Rx4)
1x SATA
RAID
8 / 10
HS SFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 450W
HS
S N Y R2
7Y51A081EA  Xeon E-2288G 8C 95W 3.7GHz 1x 16GB
(2Rx8)
1x SATA
RAID
8 / 10
HS SFF
Open bay 2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 300W
Fixed
E N Y R2
Relationship models (1-year warranty) - EMEA
7Y521000EA 1x E-2224 4C
71W 3.4GHz
1x 8GB
(1Rx8)
1x SATA
RAID
4 / 4
HS LFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 300W
Fixed
S N Y R2
7Y521001EA 1x E-2246G 6C
80W 3.6GHz
1x 16GB
(2Rx4)
1x SATA
RAID
8 / 10
HS SFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 450W
HS
S N Y R2
7Y521002EA 1x E-2276G 6C
80W 3.8GHz
1x 16GB
(2Rx4)
1x SATA
RAID
8 / 10
HS SFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 450W
HS
S N Y R2
7Y521005EA 1x E-2288G 8C 95W 3.7GHz 1x 16GB
(2Rx8)
1x SATA
RAID
8 / 10
HS SFF
Open bay 2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 300W
Fixed
S N Y R2

* Processor details: Processor quantity and model, cores, thermal design power (TDP), and core speed.
^ The server supports one fixed power supply or up to two hot-swap (HS) power supplies.

Table 9. SR250 server models (3-year warranty): India
Model
number
Intel
processor*
Memory
UDIMM
(4 max)
Storage
controller
Drive
bays
(std /
max)
Drives Eth.
LOM
I/O slots Power
supply^
XClarity Controller
Front VGA port
Tool-less Rail Kit
Power cord
TopSeller models - India
7Y72A006SG 1x E-2224G 4C
71W 3.5GHz
1x 8GB
(1Rx8)
1x SATA
RAID
4 / 4
HS LFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 450W
HS
S N Y N
7Y72A00FSG 1x E-2224G 4C
71W 3.5GHz
1x 8GB
(1Rx8)
1x RAID
530-8i
8 / 10
HS SFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 450W
HS
S N Y N
7Y72A00ASG 1x E-2234 4C
71W 3.6GHz
1x 8GB
(1Rx8)
1x SATA
RAID
4 / 4
HS LFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 450W
HS
S N Y N
7Y72A00CSG 1x E-2234 4C
71W 3.6GHz
1x 8GB
(1Rx8)
1x RAID
530-8i
8 / 10
HS SFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 450W
HS
S N Y N
7Y72A00ESG 1x E-2236 6C
80W 3.4GHz
1x 8GB
(1Rx8)
1x SATA
RAID
4 / 4
HS LFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 450W
HS
S N Y N
7Y72A009SG 1x E-2236 6C
80W 3.4GHz
1x 8GB
(1Rx8)
1x RAID
530-8i
8 / 10
HS SFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 450W
HS
S N Y N
7Y72A00BSG 1x E-2244G 4C
71W 3.8GHz
1x 8GB
(1Rx8)
1x SATA
RAID
4 / 4
HS LFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 450W
HS
S N Y N
7Y72A00DSG 1x E-2244G 4C
71W 3.8GHz
1x 8GB
(1Rx8)
1x RAID
530-8i
8 / 10
HS SFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 450W
HS
S N Y N
7Y72A008SG 1x E-2246G 6C
80W 3.6GHz
1x 8GB
(1Rx8)
1x SATA
RAID
4 / 4
HS LFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 450W
HS
S N Y N
7Y72A005SG 1x E-2246G 6C
80W 3.6GHz
1x 8GB
(1Rx8)
1x RAID
530-8i
8 / 10
HS SFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 450W
HS
S N Y N
7Y72A007SG 1x E-2274G 4C
83W 4.0GHz
1x 8GB
(1Rx8)
1x SATA
RAID
4 / 4
HS LFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 450W
HS
S N Y N
7Y72A004SG 1x E-2274G 4C
83W 4.0GHz
1x 8GB
(1Rx8)
1x RAID
530-8i
8 / 10
HS SFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 450W
HS
S N Y N

* Processor details: Processor quantity and model, cores, thermal design power (TDP), and core speed.
^ The server supports one fixed power supply or up to two hot-swap (HS) power supplies.

Table 10. SR250 server models (3-year warranty): Hong Kong, Taiwan, Korea
Model
number
Intel
processor*
Memory
UDIMM
(4 max)
Storage
controller
Drive
bays
(std /
max)
Drives Eth.
LOM
I/O slots Power
supply^
XClarity Controller
Front VGA port
Tool-less Rail Kit
Power cord
Relationship models - Hong Kong, Taiwan, Korea
7Y51A04WCN 1x E-2224G 4C
71W 3.5GHz
1x 8GB
(1Rx8)
1x SATA
RAID
4 / 4
HS LFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 300W
Fixed
S Y N N
7Y51A05DCN 1x E-2224G 4C
71W 3.5GHz
1x 8GB
(1Rx8)
1x SATA
RAID
4 / 4
HS LFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 300W
Fixed
S Y Y N
7Y51A056CN 1x E-2224G 4C
71W 3.5GHz
1x 8GB
(1Rx8)
1x SATA
RAID
4 / 4
HS LFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 450W
HS
S Y Y N
7Y51A05PCN 1x E-2224G 4C
71W 3.5GHz
1x 8GB
(1Rx8)
1x RAID
530-8i
8 / 10
HS SFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 300W
Fixed
S Y Y N
7Y51A068CN 1x E-2224G 4C
71W 3.5GHz
1x 8GB
(1Rx8)
1x RAID
530-8i
8 / 10
HS SFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 450W
HS
S Y Y N
7Y51A05HCN 1x E-2234 4C
71W 3.6GHz
1x 8GB
(1Rx8)
1x SATA
RAID
4 / 4
HS LFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 300W
Fixed
S Y Y N
7Y51A05BCN 1x E-2234 4C
71W 3.6GHz
1x 8GB
(1Rx8)
1x SATA
RAID
4 / 4
HS LFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 450W
HS
S Y Y N
7Y51A05KCN 1x E-2234 4C
71W 3.6GHz
1x 8GB
(1Rx8)
1x RAID
530-8i
8 / 10
HS SFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 300W
Fixed
S Y Y N
7Y51A05FCN 1x E-2234 4C
71W 3.6GHz
1x 8GB
(1Rx8)
1x RAID
530-8i
8 / 10
HS SFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 450W
HS
S Y Y N
7Y51A05WCN 1x E-2236 6C
80W 3.4GHz
1x 8GB
(1Rx8)
1x SATA
RAID
4 / 4
HS LFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 300W
Fixed
S Y Y N
7Y511005CN 1x E-2236 6C 80W 3.4GHz 1x 16GB
(2Rx8)
1x RAID
530-8i
8 / 10
HS SFF

Open
bay

2x 1 GbE 1x PCIe x16
1x PCIe x4
1x 450W
HS
E N Y Y
7Y51A04YCN 1x E-2236 6C
80W 3.4GHz
1x 8GB
(1Rx8)
1x SATA
RAID
4 / 4
HS LFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 450W
HS
S Y Y N
7Y51A05QCN 1x E-2236 6C
80W 3.4GHz
1x 8GB
(1Rx8)
1x RAID
530-8i
8 / 10
HS SFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 300W
Fixed
S Y Y N
7Y51A05RCN 1x E-2236 6C
80W 3.4GHz
1x 8GB
(1Rx8)
1x RAID
530-8i
8 / 10
HS SFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 450W
HS
S Y Y N
7Y51A05ACN 1x E-2244G 4C
71W 3.8GHz
1x 8GB
(1Rx8)
1x SATA
RAID
4 / 4
HS LFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 300W
Fixed
S Y Y N
7Y51A05JCN 1x E-2244G 4C
71W 3.8GHz
1x 8GB
(1Rx8)
1x SATA
RAID
4 / 4
HS LFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 450W
HS
S Y Y N
7Y51A062CN 1x E-2244G 4C
71W 3.8GHz
1x 8GB
(1Rx8)
1x RAID
530-8i
8 / 10
HS SFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 300W
Fixed
S Y Y N
7Y51A066CN 1x E-2244G 4C
71W 3.8GHz
1x 8GB
(1Rx8)
1x RAID
530-8i
8 / 10
HS SFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 450W
HS
S Y Y N
7Y51A05SCN 1x E-2246G 6C
80W 3.6GHz
1x 8GB
(1Rx8)
1x SATA
RAID
4 / 4
HS LFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 300W
Fixed
S Y Y N
7Y51A05LCN 1x E-2246G 6C
80W 3.6GHz
1x 8GB
(1Rx8)
1x SATA
RAID
4 / 4
HS LFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 450W
HS
S Y Y N
7Y51A061CN 1x E-2246G 6C
80W 3.6GHz
1x 8GB
(1Rx8)
1x RAID
530-8i
8 / 10
HS SFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 300W
Fixed
S Y Y N
7Y511006CN 1x E-     2274G 4C 83W 4.0GHz 1x 8GB
(1Rx8)
1x RAID
530-8i
8 / 10
HS SFF
Open bay 2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 450W
HS
S Y Y N
Relationship models - Taiwan
7Y51A05UCN 1x E-2236 6C
80W 3.4GHz
2x 16GB
(2Rx4)
1x SATA
RAID
4 / 4
SS LFF
2x 2TB
SATA HDD
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 300W
Fixed
S N Y N

* Processor details: Processor quantity and model, cores, thermal design power (TDP), and core speed.
^ The server supports one fixed power supply or up to two hot-swap (HS) power supplies.

Table 11. SR250 server models (3-year warranty): Japan
Model
number
Intel
processor*
Memory
UDIMM
(4 max)
Storage
controller
Drive
bays
(std /
max)
Drives Eth.
LOM
I/O slots Power
supply^
XClarity Controller
Front VGA port
Tool-less Rail Kit
Power cord
Relationship models - Japan
7Y51A06DJP 1x G5420 2C
54W 3.8GHz
1x 8GB
(1Rx8)
1x SATA
AHCI
4 / 4
HS LFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 450W
HS
A N Y N
7Y51A06AJP 1x E-2224 4C
71W 3.4GHz
1x 8GB
(1Rx8)
1x SATA
AHCI
4 / 4
HS LFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 450W
HS
A N Y N
7Y51A06BJP 1x E-2224 4C
71W 3.4GHz
1x 8GB
(1Rx8)
1x RAID
530-8i
8 / 10
HS SFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 450W
HS
A N Y N
7Y51A06CJP 1x E-2224 4C
71W 3.4GHz
1x 8GB
(1Rx8)
1x RAID
730-8i 2GB
8 / 10
HS SFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 450W
HS
A N Y N
7Y51A06EJP 1x E-2224G 4C
71W 3.5GHz
1x 8GB
(1Rx8)
1x SATA
AHCI
4 / 4
HS LFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 450W
HS
A N Y N
7Y51A06JJP 1x E-2226G 6C
80W 3.4GHz
1x 8GB
(1Rx8)
1x SATA
AHCI
4 / 4
HS LFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 450W
HS
A N Y N
7Y51A06UJP 1x E-2226G 6C
80W 3.4GHz
1x 8GB
(1Rx8)
1x RAID
530-8i
8 / 10
HS SFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 450W
HS
A N Y N
7Y51A06YJP 1x E-2226G 6C
80W 3.4GHz
1x 8GB
(1Rx8)
1x RAID
730-8i 2GB
8 / 10
HS SFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 450W
HS
A N Y N
7Y51A06FJP 1x E-2234 4C
71W 3.6GHz
1x 8GB
(1Rx8)
1x SATA
AHCI
4 / 4
HS LFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 450W
HS
A N Y N
7Y51A06RJP 1x E-2234 4C
71W 3.6GHz
1x 8GB
(1Rx8)
1x RAID
530-8i
8 / 10
HS SFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 450W
HS
A N Y N
7Y51A06ZJP 1x E-2234 4C
71W 3.6GHz
1x 8GB
(1Rx8)
1x RAID
730-8i 2GB
8 / 10
HS SFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 450W
HS
A N Y N
7Y51A06KJP 1x E-2236 6C
80W 3.4GHz
1x 8GB
(1Rx8)
1x SATA
AHCI
4 / 4
HS LFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 450W
HS
A N Y N
7Y51A06GJP 1x E-2244G 4C
71W 3.8GHz
1x 8GB
(1Rx8)
1x SATA
AHCI
4 / 4
HS LFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 450W
HS
A N Y N
7Y51A06SJP 1x E-2244G 4C
71W 3.8GHz
1x 8GB
(1Rx8)
1x RAID
530-8i
8 / 10
HS SFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 450W
HS
A N Y N
7Y51A070JP 1x E-2244G 4C
71W 3.8GHz
1x 8GB
(1Rx8)
1x RAID
730-8i 2GB
8 / 10
HS SFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 450W
HS
A N Y N
7Y51A06LJP 1x E-2246G 6C
80W 3.6GHz
1x 8GB
(1Rx8)
1x SATA
AHCI
4 / 4
HS LFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 450W
HS
A N Y N
7Y51A06HJP 1x E-2274G 4C
83W 4.0GHz
1x 8GB
(1Rx8)
1x SATA
AHCI
4 / 4
HS LFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 450W
HS
A N Y N
7Y51A06TJP 1x E-2274G 4C
83W 4.0GHz
1x 8GB
(1Rx8)
1x RAID
530-8i
8 / 10
HS SFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 450W
HS
A N Y N
7Y51A071JP 1x E-2274G 4C
83W 4.0GHz
1x 8GB
(1Rx8)
1x RAID
730-8i 2GB
8 / 10
HS SFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 450W
HS
A N Y N
7Y51A06MJP 1x E-2276G 6C
80W 3.8GHz
1x 8GB
(1Rx8)
1x SATA
AHCI
4 / 4
HS LFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 450W
HS
A N Y N
7Y51A06PJP 1x E-2278G 8C
80W 3.4GHz
1x 8GB
(1Rx8)
1x SATA
AHCI
4 / 4
HS LFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 450W
HS
A N Y N
7Y51A06WJP 1x E-2278G 8C
80W 3.4GHz
1x 8GB
(1Rx8)
1x RAID
530-8i
8 / 10
HS SFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 450W
HS
A N Y N
7Y51A073JP 1x E-2278G 8C
80W 3.4GHz
1x 8GB
(1Rx8)
1x RAID
730-8i 2GB
8 / 10
HS SFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 450W
HS
A N Y N
7Y51A06NJP 1x E-2286G 6C
95W 4.0GHz
1x 8GB
(1Rx8)
1x SATA
AHCI
4 / 4
HS LFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 450W
HS
A N Y N
7Y51A06VJP 1x E-2286G 6C
95W 4.0GHz
1x 8GB
(1Rx8)
1x RAID
530-8i
8 / 10
HS SFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 450W
HS
A N Y N
7Y51A072JP 1x E-2286G 6C
95W 4.0GHz
1x 8GB
(1Rx8)
1x RAID
730-8i 2GB
8 / 10
HS SFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 450W
HS
A N Y N
7Y51A06QJP 1x E-2288G 8C
95W 3.7GHz
1x 8GB
(1Rx8)
1x SATA
AHCI
4 / 4
HS LFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 450W
HS
A N Y N
7Y51A06XJP 1x E-2288G 8C
95W 3.7GHz
1x 8GB
(1Rx8)
1x RAID
530-8i
8 / 10
HS SFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 450W
HS
A N Y N
7Y51A074JP 1x E-2288G 8C
95W 3.7GHz
1x 8GB
(1Rx8)
1x RAID
730-8i 2GB
8 / 10
HS SFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 450W
HS
A N Y N

* Processor details: Processor quantity and model, cores, thermal design power (TDP), and core speed.
^ The server supports one fixed power supply or up to two hot-swap (HS) power supplies.

Table 12. SR250 server models (3-year warranty): ASEAN
Model
number
Intel
processor*
Memory
UDIMM
(4 max)
Storage
controller
Drive
bays
(std /
max)
Drives Eth.
LOM
I/O slots Power
supply^
XClarity Controller
Front VGA port
Tool-less Rail Kit
Power cord
Relationship models - ASEAN
7Y51A05NSG 1x E-2224G 4C
71W 3.5GHz
1x 8GB
(1Rx8)
1x SATA
RAID
4 / 4
HS LFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 300W
Fixed
S Y Y N
7Y51A04SSG 1x E-2224G 4C
71W 3.5GHz
1x 8GB
(1Rx8)
1x SATA
RAID
4 / 4
HS LFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 450W
HS
S Y Y N
7Y51A04TSG 1x E-2224G 4C
71W 3.5GHz
1x 8GB
(1Rx8)
1x RAID
530-8i
8 / 10
HS SFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 300W
Fixed
S Y Y N
7Y51A067SG 1x E-2224G 4C
71W 3.5GHz
1x 8GB
(1Rx8)
1x RAID
530-8i
8 / 10
HS SFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 450W
HS
S Y Y N
7Y51A05MSG 1x E-2234 4C
71W 3.6GHz
1x 8GB
(1Rx8)
1x SATA
RAID
4 / 4
HS LFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 300W
Fixed
S Y Y N
7Y51A052SG 1x E-2234 4C
71W 3.6GHz
1x 8GB
(1Rx8)
1x SATA
RAID
4 / 4
HS LFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 450W
HS
S Y Y N
7Y51A04VSG 1x E-2234 4C
71W 3.6GHz
1x 8GB
(1Rx8)
1x RAID
530-8i
8 / 10
HS SFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 300W
Fixed
S Y Y N
7Y51A05GSG 1x E-2234 4C
71W 3.6GHz
1x 8GB
(1Rx8)
1x RAID
530-8i
8 / 10
HS SFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 450W
HS
S Y Y N
7Y51A04ZSG 1x E-2236 6C
80W 3.4GHz
1x 8GB
(1Rx8)
1x SATA
RAID
4 / 4
HS LFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 300W
Fixed
S Y Y N
7Y51A058SG 1x E-2236 6C
80W 3.4GHz
1x 8GB
(1Rx8)
1x SATA
RAID
4 / 4
HS LFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 450W
HS
S Y Y N
7Y51A05TSG 1x E-2236 6C
80W 3.4GHz
1x 8GB
(1Rx8)
1x RAID
530-8i
8 / 10
HS SFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 300W
Fixed
S Y Y N
7Y51A05ZSG 1x E-2236 6C
80W 3.4GHz
1x 8GB
(1Rx8)
1x RAID
530-8i
8 / 10
HS SFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 450W
HS
S Y Y N
7Y51A059SG 1x E-2244G 4C
71W 3.8GHz
1x 8GB
(1Rx8)
1x SATA
RAID
4 / 4
HS LFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 300W
Fixed
S Y Y N
7Y51A055SG 1x E-2244G 4C
71W 3.8GHz
1x 8GB
(1Rx8)
1x SATA
RAID
4 / 4
HS LFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 450W
HS
S Y Y N
7Y51A063SG 1x E-2244G 4C
71W 3.8GHz
1x 8GB
(1Rx8)
1x RAID
530-8i
8 / 10
HS SFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 300W
Fixed
S Y Y N
7Y51A05CSG 1x E-2244G 4C
71W 3.8GHz
1x 8GB
(1Rx8)
1x RAID
530-8i
8 / 10
HS SFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 450W
HS
S Y Y N
7Y51A05XSG 1x E-2244G 4C
71W 3.8GHz
1x 8GB
(1Rx8)
1x RAID
530-8i
8 / 10
HS SFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 450W
HS
S Y Y N
7Y51A057SG 1x E-2246G 6C
80W 3.6GHz
1x 8GB
(1Rx8)
1x SATA
RAID
4 / 4
HS LFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 300W
Fixed
S Y Y N
7Y51A04XSG 1x E-2246G 6C
80W 3.6GHz
1x 8GB
(1Rx8)
1x SATA
RAID
4 / 4
HS LFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 450W
HS
S Y Y N
7Y51A065SG 1x E-2246G 6C
80W 3.6GHz
1x 8GB
(1Rx8)
1x RAID
530-8i
8 / 10
HS SFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 300W
Fixed
S Y Y N
7Y51A064SG 1x E-2246G 6C
80W 3.6GHz
1x 8GB
(1Rx8)
1x RAID
530-8i
8 / 10
HS SFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 450W
HS
S Y Y N

* Processor details: Processor quantity and model, cores, thermal design power (TDP), and core speed.
^ The server supports one fixed power supply or up to two hot-swap (HS) power supplies.

Table 13. SR250 server models (3-year warranty): Australia and New Zealand
Model
number
Intel
processor*
Memory
UDIMM
(4 max)
Storage
controller
Drive
bays
(std /
max)
Drives Eth.
LOM
I/O slots Power
supply^
XClarity Controller
Front VGA port
Tool-less Rail Kit
Power cord
Relationship models - Australia and New Zealand
7Y51A060AU 1x E-2224G 4C
71W 3.5GHz
1x 8GB
(1Rx8)
1x SATA
AHCI
4 / 4
HS LFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 450W
HS
S Y Y R1
TopSeller models - Australia and New Zealand
7Y51A07JAU 1x G4930 2C
54W 3.2GHz
1x 8GB
(1Rx8)
1x SATA
AHCI
4 / 4
SS LFF
Open
bay
2x 1 GbE 1x PCIe x16
1x PCIe x4
1x 300W
Fixed
S N Y R2
7Y51A05YAU 1x E-2246G 6C
80W 3.6GHz
1x 16GB
(2Rx4)
1x SATA
AHCI
4 / 4
HS LFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 450W
HS
S Y Y R1
7Y51A069AU 1x E-2246G 6C
80W 3.6GHz
1x 16GB
(2Rx4)
1x SATA
AHCI
8 / 10
HS SFF
Open
bay
2x 1 GbE 2x PCIe x8
1x PCIe x4
1x 450W
HS
S Y Y R1

* Processor details: Processor quantity and model, cores, thermal design power (TDP), and core speed.
^ The server supports one fixed power supply or up to two hot-swap (HS) power supplies.

Processors

The SR250 supports one processor from the Intel product family formerly known by the codename "Coffee Lake-S Refresh". This includes processors from the Intel Xeon E, Core i3, Pentium Gold, and Celeron G families.

Topics in this section:

The server supports the processors that are listed in the following table.

Integrated graphics and management: Xeon processors with a G suffix include integrated graphics, however, this functionality is not used in the SR250. Instead, graphics support is provided by XClarity Controller (XCC), or by an GPU add-in card. Similarly system management of the SR250 is handled by XCC and as a result, the AMT management processor is disabled.

Table 14. Processor specifications (HT = Hyper-Threading, TB = Turbo Boost, VT = Virtualization Technology)
CPU
model
Core frequency
(Base / TB Max)
Number
of cores /
threads
Cache Max DDR4
frequency
Max
memory
capacity
Bus
speed
TDP ECC HT TB VT-x VT-d SGX
Intel Xeon E processors
E-2224 3.40 / 4.60 GHz 4 / 4 8 MB 2666 MHz 128 GB 8 GT/s 71 W Yes No Yes Yes Yes No
E-2224G 3.50 / 4.70 GHz 4 / 4 8 MB 2666 MHz 128 GB 8 GT/s 71 W Yes No Yes Yes Yes No
E-2226G 3.40 / 4.70 GHz 6 / 6 12 MB 2666 MHz 128 GB 8 GT/s 80 W Yes No Yes Yes Yes No
E-2234 3.60 / 4.80 GHz 4 / 8 8 MB 2666 MHz 128 GB 8 GT/s 71 W Yes Yes Yes Yes Yes No
E-2236 3.40 / 4.80 GHz 6 / 12 12 MB 2666 MHz 128 GB 8 GT/s 80 W Yes Yes Yes Yes Yes No
E-2244G 3.80 / 4.80 GHz 4 / 8 8 MB 2666 MHz 128 GB 8 GT/s 71 W Yes Yes Yes Yes Yes No
E-2246G 3.60 / 4.80 GHz 6 / 12 12 MB 2666 MHz 128 GB 8 GT/s 80 W Yes Yes Yes Yes Yes No
E-2274G 4.00 / 4.90 GHz 4 / 8 8 MB 2666 MHz 128 GB 8 GT/s 83 W Yes Yes Yes Yes Yes Yes
E-2276G 3.80 / 4.90 GHz 6 / 12 12 MB 2666 MHz 128 GB 8 GT/s 80 W Yes Yes Yes Yes Yes Yes
E-2278G 3.40 / 5.00 GHz 8 / 16 16 MB 2666 MHz 128 GB 8 GT/s 80 W Yes Yes Yes Yes Yes Yes
E-2286G 4.00 / 4.90 GHz 6 / 12 12 MB 2666 MHz 128 GB 8 GT/s 95 W Yes Yes Yes Yes Yes Yes
E-2288G 3.70 / 5.00 GHz 8 / 16 16 MB 2666 MHz 128 GB 8 GT/s 95 W Yes Yes Yes Yes Yes Yes
Intel Core i3 processors
i3-9100 3.60 / 4.20 GHz 4 / 4 6 MB 2400 MHz 64 GB 8 GT/s 65 W Yes No Yes Yes Yes No
i3-9100T 3.10 / 3.70 GHz 4 / 4 6 MB 2400 MHz 64 GB 8 GT/s 35 W Yes No Yes Yes Yes No
i3-9300 3.70 / 4.30 GHz 4 / 4 8 MB 2400 MHz 64 GB 8 GT/s 62 W Yes No Yes Yes Yes No
i3-9300T 3.20 / 3.80 GHz 4 / 4 8 MB 2400 MHz 64 GB 8 GT/s 35 W Yes No Yes Yes Yes No
i3-9320 3.70 / 4.40 GHz 4 / 4 8 MB 2400 MHz 64 GB 8 GT/s 62 W Yes No Yes Yes Yes No
Intel Pentium Gold processors
G5420 3.80 GHz 2 / 4 4 MB 2400 MHz 64 GB 8 GT/s 54 W Yes Yes No Yes Yes No
G5420T 3.20 GHz 2 / 4 4 MB 2400 MHz 64 GB 8 GT/s 35 W Yes Yes No Yes Yes No
G5600T 3.30 GHz 2 / 4 4 MB 2400 MHz 64 GB 8 GT/s 35 W Yes Yes No Yes Yes No
G5620 4.00 GHz 2 / 4 4 MB 2400 MHz 64 GB 8 GT/s 54 W Yes Yes No Yes Yes No
Intel Celeron processors
G4930 3.20 GHz 2 / 2 2 MB 2400 MHz 64 GB 8 GT/s 54 W Yes No No Yes Yes No
G4930T 3.00 GHz 2 / 2 2 MB 2400 MHz 64 GB 8 GT/s 35 W Yes No No Yes Yes No
G4950 3.30 GHz 2 / 2 2 MB 2400 MHz 64 GB 8 GT/s 54 W Yes No No Yes Yes No

The following table lists feature codes for the processors that are available for the SR250 server.

Table 15. Processor feature codes
Feature code Description
Intel Xeon E processors
BAJY Intel Xeon E-2224 4C 71W 3.4GHz Processor
BAJX Intel Xeon E-2224G 4C 71W 3.5GHz Processor
BAJW Intel Xeon E-2226G 6C 80W 3.4GHz Processor
BAJV Intel Xeon E-2234 4C 71W 3.6GHz Processor
BAJU Intel Xeon E-2236 6C 80W 3.4GHz Processor
BAJT Intel Xeon E-2244G 4C 71W 3.8GHz Processor
BAJS Intel Xeon E-2246G 6C 80W 3.6GHz Processor
BAJR Intel Xeon E-2274G 4C 83W 4.0GHz Processor
BAJQ Intel Xeon E-2276G 6C 80W 3.8GHz Processor
BAJN Intel Xeon E-2278G 8C 80W 3.4GHz Processor
BAJP Intel Xeon E-2286G 6C 95W 4.0GHz Processor
BAJM Intel Xeon E-2288G 8C 95W 3.7GHz Processor
Intel Core i3 processors
BAK4 Intel Core i3-9100 4C 65W 3.6GHz Processor
BAK3 Intel Core i3-9100T 4C 35W 3.1GHz Processor
BAK2 Intel Core i3-9300 4C 62W 3.7GHz Processor
BAK0 Intel Core i3-9300T 4C 35W 3.2GHz Processor
BAK1 Intel Core i3-9320 4C 62W 3.7GHz Processor
Intel Pentium Gold processors
BAK7 Intel Pentium G5420 2C 54W 3.8GHz Processor
BAK8 Intel Pentium G5420T 2C 35W 3.2GHz Processor
BAK6 Intel Pentium G5600T 2C 35W 3.3GHz Processor
BAK5 Intel Pentium G5620 2C 54W 4.0GHz Processor
Intel Celeron G processors
BAKB Intel Celeron G4930 2C 54W 3.2GHz Processor
BAKA Intel Celeron G4930T 2C 35W 3.0GHz Processor
BAK9 Intel Celeron G4950 2C 54W 3.3GHz Processor

UEFI operating modes

The SR250 offers preset operating modes that affect energy consumption and performance. These modes are a collection of predefined low-level UEFI settings that simplify the task of tuning the server to suit your business and workload requirements.

The following table lists the feature codes that allow you to specify the mode you wish to preset in the factory for CTO orders.

UK and EU customers: For compliance with the ERP Lot9 regulation, you should select feature BFYE. For some systems, you may not be able to make a selection, in which case, it will be automatically derived by the configurator.

Table 16. UEFI operating mode presets in DCSC
Feature code Description
BFYB Operating mode selection for: "Maximum Performance Mode"
BFYC Operating mode selection for: "Minimal Power Mode"
BFYD Operating mode selection for: "Efficiency Favoring Power Savings Mode"
BFYE Operating mode selection for: "Efficiency - Favoring Performance Mode"

The preset modes for the SR250 are as follows:

  • Maximum Performance Mode (feature BFYB): Achieves maximum performance but with higher power consumption and lower energy efficiency.
  • Minimal Power Mode (feature BFYC): Minimize the absolute power consumption of the system.
  • Efficiency Favoring Power Savings Mode (feature BFYD): Maximize the performance/watt efficiency with a bias towards power savings. This is the favored mode for SPECpower benchmark testing, for example.
  • Efficiency Favoring Performance Mode (feature BFYE): Maximize the performance/watt efficiency with a bias towards performance. This is the favored mode for Energy Star certification, for example.

Memory

The SR250 server supports up to 4 TruDDR4 memory UDIMMs with ECC protection. The processor has two memory channels with two DIMMs per channel.

Lenovo TruDDR4 memory uses the highest-quality components sourced from Tier 1 DRAM suppliers and only memory that meets strict requirements is selected. It is compatibility tested and tuned on every ThinkSystem server to maximize performance and reliability.

TruDDR4 memory has a unique signature programmed into the DIMM, which enables Lenovo servers to verify whether the memory installed is qualified and supported. Lenovo qualified and supported TruDDR4 memory is covered by Lenovo warranty, and service and support provided worldwide.

The following rules apply when selecting the memory configuration:

  • The server supports memory configurations with 1, 2, 3, or 4 UDIMMs.
  • Mixing UDIMMs of different capacity is not supported.
  • All DIMMs in the server operate at the same speed up to 2666 MHz, which is determined by the maximum memory speed supported by the specific processor (see Processors for details).
    Note: Maximum memory speed can be achieved when Max performance mode is enabled in UEFI.
  • The server supports up to 128 GB of memory.
    Note: 32 GB UDIMMs are supported only with the Intel Xeon E Series processors; Core i3, Pentium Gold, and Celeron G Series processors do not support 32 GB UDIMMs.

The following table lists memory options available for the SR250 server.

Table 17. Memory options
Description Part number Feature code Maximum quantity
ThinkSystem 8GB TruDDR4 2666MHz (1Rx8, 1.2V) ECC UDIMM 4ZC7A08696 B35J 4
ThinkSystem 16GB TruDDR4 2666MHz (2Rx8, 1.2V) ECC UDIMM 4ZC7A08699 B35K 4
ThinkSystem 32GB TruDDR4 2666MHz (2Rx8, 1.2V) ECC UDIMM 4ZC7A15142 B96E 4

Internal storage

The SR250 server supports the following internal drive bay configurations:

  1. 4 LFF SATA Simple Swap drive bays
  2. 4 LFF SAS/SATA hot-swap drive bays
  3. 8 SFF SAS/SATA hot-swap drive bays
  4. 10 SFF hot-swap drive bays:
    1. 10x 2.5" SAS/SATA
    2. 8x 2.5" SAS/SATA & 2x 2.5" NVMe PCIe

In addition, the SR250 server models can be configured with one internal M.2 SATA non-hot-swap SSD.

The following figure shows the internal drive bay configurations.

Internal drive configurations
Figure 7. Internal drive bay configurations

The following table lists the internal storage options for the SR250 server.

X30 and X40 adapters: Some of the kits are for X30 adapters, which correspond to any of the RAID 930, 730, 530 or HBA 430 storage adapters. Some kits are for use with X40 adapters, which correspond to RAID 940 and HBA 440 storage adapters.

Table 18. Internal storage options
Part number Feature code Description Maximum quantity
 Simple-swap (SS) backplane kits
None* BMNP ThinkSystem SR250 4x3.5" SS BP BKT Kit v2 1
None* B407 ThinkSystem SR250 4x3.5" SS BP BKT Kit 1
4M17A80597 BN11 ThinkSystem SR250/SR150 4x3.5" SS HBA BP Bracket Kit v2 (for X30 RAID/HBA) 1
4M17A14200 B408 ThinkSystem SR250/SR150 4x3.5" SS Backplane Bracket Kit for HW X30 RAID/HBA 1
4M17A80601 BM7L ThinkSystem SR250 Series 4x3.5" Simple Swap Backplane Kit for X40 RAID/HBA 1
 Hot-swap (HS) backplanes and kits
None* BMPU ThinkSystem SR250 Series 8x2.5" Hot Swap SAS/SATA Backplane Kit for X350/X40 RAID/HBA v2 1
None* B413 ThinkSystem SR250 2.5" SATA/SAS 8-Bay BP 1
4M17A80605 BMPX ThinkSystem SR250 3.5" SATA/SAS 4-Bay BP with X30 RAID Cable Kit v2 1
4M17A13565 B412 ThinkSystem SR250 3.5" HS SATA/SAS 4-Bay Backplane with X30 RAID Cable Kit (for X30 RAID/HBA) 1
4M17A80607 BMPX ThinkSystem SR250 3.5" Hot Swap SAS/SATA 4-Bay Backplane Kit for X40 RAID v2 1
4M17A80602 BN9K ThinkSystem SR250 3.5" HS SATA/SAS 4-Bay Backplane with X40 RAID Cable Kit 1
4C57A80517 BMPV ThinkSystem SR250 2.5" Anybay 10-Bay BP v2 1
4C57A12112 B414 ThinkSystem SR250 2.5" Anybay 10-Bay BP 1
 Cables for hot-swap backplanes
None* B405 ThinkSystem SR250 3.5"x4 OB MSHD to BP MSHD Cable (4x3.5" HS SATA x4 Cable for Onboard SATA) 1
None* B406 ThinkSystem SR250 2.5"x8 OB MSHD/SATA to BP 2xMSHD Cable (8x2.5" HS SATA 2x4 Cable for Onboard SATA) 1
4Z57A12652 B415 ThinkSystem SR250 3.5"/2.5" HS SAS/SATA x4 Cable for HW X30 RAID/HBA (for X30 RAID/HBA) 3
4Z57A80610 BN9L ThinkSystem SR250 3.5"/2.5" HS SAS/SATA x4 Cable for HW X40 RAID/HBA 3
4Z57A12651 B416 ThinkSystem SR250 2.5"x10 NVMe Cable 2

* Factory-installed only, no field upgrade.

Configuration notes:

  • The AnyBay backplane allows either SAS/SATA drives or NVMe PCIe drives in the drive bays 8 and 9.
  • Configurations with NVMe PCIe drives are supported only for Machine Types 7Y51, 7Y52, and 7Y72; Machine Type 7Y73 does not support configurations with NVMe PCIe drives.
  • Field upgrades for models with 3.5-inch drive bays:
    • Models with 4x 3.5" SS drive bays and an onboard SATA controller can be upgraded to support a hardware RAID controller or HBA by using one of the following:
      • For use with X30 RAID/HBA adapters: 4x3.5" SS Backplane Bracket Kit for HW RAID/HBA (4M17A80597 or 4M17A14200)
      • For use with X40 RAID/HBA adapters: 4x3.5" SS Backplane Bracket Kit for HW X40 RAID/HBA (4M17A80601)
    • Models with 4x 3.5" SS drive bays can be upgraded to support 4x 3.5" HS drive bays and a hardware RAID controller or HBA by using one of the following:
      • For use with X30 RAID/HBA adapters: 3.5" HS SATA/SAS 4-Bay Backplane Cable Kit (4M17A80605 or 4M17A13565). The kit includes the hot-swap backplane (BMPX or B412) and the SAS/SATA cable for HW RAID/HBA (B415).
      • For use with X40 RAID/HBA adapters: 3.5" HS SATA/SAS 4-Bay Backplane with X40 RAID Cable Kit (4M17A80607 or 4M17A80602). The kit includes the backplane and the cable for connecting to the X40 adapters
    • Models with 4x 3.5" HS drive bays and an onboard SATA controller can be upgraded to support a hardware RAID controller or HBA by using one of the following:
      • For use with X30 RAID/HBA adapters: 3.5"/2.5" HS SAS/SATA x4 Cable for HW RAID/HBA (4Z57A12652)
      • For use with X40 RAID/HBA adapters: 3.5"/2.5" HS SAS/SATA x4 Cable for HW X40 RAID/HBA (4Z57A80610)
  • Field upgrades for models with 2.5-inch drive bays:
    • Models with 8x 2.5" HS drive bays and an onboard SATA controller can be upgraded to support a hardware RAID controller or HBA by using two of the following:
      • For use with X30 RAID/HBA adapters: 3.5"/2.5" HS SAS/SATA x4 Cable for HW RAID/HBA (4Z57A12652)
      • For use with X40 RAID/HBA adapters: 3.5"/2.5" HS SAS/SATA x4 Cable for HW X40 RAID/HBA (4Z57A80610)
    • Models with 8x 2.5" HS drive bays and an onboard SATA controller can be upgraded to support 10x 2.5" HS drive bays and a hardware RAID controller or HBA by using the 2.5" HS AnyBay 10-Bay Backplane (4C57A80517 or 4C57A12112). The following additional cables are needed:
      • NVMe support: Two 3.5"/2.5" HS SAS/SATA x4 Cables for HW RAID/HBA (4Z57A12652 for X30 or 4Z57A80610 for X40) and two 10x2.5" HS NVMe Cables (4Z57A12651).
      • No NVMe support: Three 3.5"/2.5" HS SAS/SATA x4 Cables for HW RAID/HBA (4Z57A12652 for X30 or 4Z57A80610 for X40).
    • Models with 8x 2.5" HS drive bays and a hardware RAID controller or HBA can be upgraded to support 10x 2.5" HS drive bays by using the 2.5" HS AnyBay 10-Bay Backplane (4C57A80517 or 4C57A12112). The following additional cables are needed:
      • NVMe support: Two 10x2.5" HS NVMe Cables (4Z57A12651).
      • No NVMe support: One 3.5"/2.5" HS SAS/SATA x4 Cable for HW RAID/HBA (4Z57A12652 for X30 or 4Z57A80610 for X40).
    • Models with 10x 2.5" HS drive bays and an NVMe Switch Adapter can be upgraded to support a hardware RAID controller or HBA by using two of the following:
      • For use with X30 RAID/HBA adapters: 3.5"/2.5" HS SAS/SATA x4 Cable for HW RAID/HBA (4Z57A12652)
      • For use with X40 RAID/HBA adapters: 3.5"/2.5" HS SAS/SATA x4 Cable for HW X40 RAID/HBA (4Z57A80610)
  • Controllers for internal storage are not included with the field upgrade options.
  • The M.2 SSD cannot be used in the configurations with eight drives that are connected to the onboard SATA controller (the SATA port 7 is shared between the drive bay 7 and the M.2 connector).

The following table lists supported internal storage configurations with the SAS/SATA and AnyBay backplanes.

Table 19. Internal storage configurations
Drive bay configuration Backplane and cable type and quantity Storage controller quantity and type*
4x 3.5" SS BP SW (BMNP / B407)
4x 3.5" SS BP HW (BN11 / B408)
4x 3.5" HS BP (BMPX / B412)
8x 2.5" HS BP (BMPU / B413)
10x 2.5" HS BP (B414)
4x3.5" HS x4 Cable SW (B405)
8x2.5" HS 2x4 Cable SW (B406)
3.5"/2.5" HS x4 Cable HW (B415)
10x 2.5" HS NVMe Cable (B416)
3.5" chassis (Feature code B403)
4x 3.5-in. SATA simple-swap 1 0 0 0 0 0 0 0 0 1x Onboard AHCI / RSTe (4)
0 1 0 0 0 0 0 0 0 1x RAID 530/730/930-8i/930-16i (4)
1x 430-8i/16i HBA (4)
4x 3.5-in. SAS/SATA hot-swap 0 0 1 0 0 1 0 0 0 1x Onboard AHCI / RSTe (4)
0 0 1 0 0 0 0 1 0 1x RAID 530/730/930-8i/930-16i (4)
1x 430-8i/16i HBA (4)
2.5" chassis (Feature code B404)
8x 2.5-in. SAS/SATA hot-swap 0 0 0 1 0 0 1 0 0 1x Onboard AHCI / RSTe (8)
0 0 0 1 0 0 0 2 0 1x RAID 530/730/930-8i/930-16i (8)
1x 430-8i/16i HBA (8)
10x 2.5-in. SAS/SATA hot-swap 0 0 0 0 1 0 0 3 0 1x RAID 930-16i (10)
1x 430-16i HBA (10)
8x 2.5-in. SAS/SATA +
2x 2.5-in. NVMe hot-swap
0 0 0 0 1 0 0 2 2 1x RAID 530/730/930-8i/930-16i (8) + 1x 1610-4P (2)
1x 430-8i/16i HBA (8) + 1x 1610-4P (2)
2x 2.5-in. NVMe hot-swap 0 0 0 0 1 0 0 0 2 1x 1610-4P (2)

* The number in brackets (x) specifies the quantity of drive bays connected to each of the controllers.

SED encryption key management with SKLM

The server supports self-encrypting drives (SEDs) as listed in the Internal drive options section. To effectively manage a large deployment of these drives in Lenovo servers, IBM Security Key Lifecycle Manager (SKLM) offers a centralized key management solution.

The IBM Security Key Lifecycle Manager software is available from Lenovo using the ordering information listed in the following table.

Table 20. IBM Security Key Lifecycle Manager licenses
Part number Description
7S0A007FWW IBM Security Key Lifecycle Manager Basic Edition Install License + SW Subscription & Support 12 Months
7S0A007HWW IBM Security Key Lifecycle Manager For Raw Decimal Terabyte Storage Resource Value Unit License + SW Subscription & Support 12 Months
7S0A007KWW IBM Security Key Lifecycle Manager For Raw Decimal Petabyte Storage Resource Value Unit License + SW Subscription & Support 12 Months
7S0A007MWW IBM Security Key Lifecycle Manager For Usable Decimal Terabyte Storage Resource Value Unit License + SW Subscription & Support 12 Months
7S0A007PWW IBM Security Key Lifecycle Manager For Usable Decimal Petabyte Storage Resource Value Unit License + SW Subscription & Support 12 Months

Controllers for internal storage

The following table lists the storage controllers and options for internal storage of the SR250 server.

Table 21. RAID controllers and HBAs for internal storage
Part number Feature code Description Maximum quantity I/O slots supported
6 Gbps SATA controllers
None* None* Onboard AHCI (non-RAID) / Intel RSTe (RAID) 1 -
12 Gb SAS/SATA RAID controllers
7Y37A01082 AUNG ThinkSystem RAID 530-8i PCIe 12Gb Adapter 1 2, 3
4Y37A78834 BMFT ThinkSystem RAID 540-8i PCIe Gen4 12Gb Adapter 1 2, 3
7Y37A01083 AUNH ThinkSystem RAID 730-8i 1GB Cache PCIe 12Gb Adapter 1 2, 3
4Y37A09722 B4RQ ThinkSystem RAID 730-8i 2GB Flash PCIe 12Gb Adapter 1 2, 3
7Y37A01084 AUNJ ThinkSystem RAID 930-8i 2GB Flash PCIe 12Gb Adapter 1 2, 3
7Y37A01085 AUNK ThinkSystem RAID 930-16i 4GB Flash PCIe 12Gb Adapter 1 2, 3
4Y37A09728 B8NY ThinkSystem RAID 940-8i 4GB Flash PCIe Gen4 12Gb Adapter 1 2, 3
4Y37A78600 BM35 ThinkSystem RAID 940-16i 4GB Flash PCIe Gen4 12Gb Adapter 1 2, 3
12 Gb SAS/SATA HBAs (non-RAID)
7Y37A01088 AUNL ThinkSystem 430-8i SAS/SATA 12Gb HBA 1 2, 3
7Y37A01089 AUNM ThinkSystem 430-16i SAS/SATA 12Gb HBA 1 2, 3
4Y37A78601 BM51 ThinkSystem 440-8i SAS/SATA PCIe Gen4 12Gb HBA 1 2, 3
4Y37A78602 BM50 ThinkSystem 440-16i SAS/SATA PCIe Gen4 12Gb HBA 1 2, 3
NVMe PCIe adapters (non-RAID)
7Y37A01081 AUV2 ThinkSystem 1610-4P NVMe Switch Adapter 1 2

* The onboard SATA controller integrated into the Intel C246 Platform Controller Hub (PCH) supports non-RAID (JBOD) AHCI mode or a hardware-assist, software RAID feature (Intel Rapid Storage Technology Enterprise [RSTe]).

For a comparison of the functions of the supported storage adapters, see the ThinkSystem RAID Adapter and HBA Reference:
https://lenovopress.com/lp1288-thinksystem-raid-adapter-and-hba-reference#sr250-support=SR250

Configuration notes:

  • The onboard SATA controller does not consume a PCIe slot.
  • SAS RAID controllers and HBAs for internal storage are supported in the following PCIe slots:
    • PCIe slot 2 on the PCIe x8/x8 Riser Card (feature code B418):
      • No additional PCIe adapters are installed
      • One additional PCIe adapter is installed in the server in the PCIe slot 1
    • PCIe slot 3 on the system board:
      • Two additional PCIe adapters are installed in the server in the PCIe slots 1 and 2
      • A GPU adapter is installed in the server in the PCIe slot 2
      • The PCIe x16 Riser Card (feature code B417) is installed in the server
  • The total quantity of the RAID 730-8i 2GB, 930-8i, 930-16i, and 930-8e controllers in the server must not exceed 1 (up to 1 supercapacitor can be mounted in the server).
  • The 1610-4P NVMe Switch Adapter is supported in the PCIe slot 2 supplied by the PCIe x8 or x16 riser card.
  • The 1610-4P NVMe Switch Adapter provides two PCIe 3.0 x4 ports for JBOD (non-RAID) connectivity to U.2 NVMe PCIe SSDs in the drive bays 8 and 9.
  • The onboard Intel RSTe is not supported by virtualization hypervisors, including VMware vSphere (ESXi), Linux KVM, Xen, and Microsoft Hyper-V.
  • The onboard Intel RSTe supports up to eight drives in a RAID-0 or RAID-5 array, two drives in a RAID-1 array, and four drives in a RAID-10 array. In a Windows Server-based environment, the onboard Intel RSTe supports up to six drives in a RAID-0 or RAID-5 array.

For more information, see the list of Product Guides in the following categories:

Drives for internal storage

The following tables list the drive options for internal storage of the server.

M.2 drives:

M.2 drive support: The use of M.2 drives requires an additional adapter as described in the Internal storage section.

PCIe 4.0 NVMe drive support: When installed in this server, PCIe 4.0 NVMe drives will operate at PCIe 3.0 speeds.

Table 22. 2.5-inch hot-swap 12 Gb SAS HDDs
Part number Feature
code
Description SED
support
Max
Qty
2.5-inch hot-swap HDDs - 12 Gb SAS 15K
7XB7A00021 AULV ThinkSystem 2.5" 300GB 15K SAS 12Gb Hot Swap 512n HDD No 10
7XB7A00022 AULW ThinkSystem 2.5" 600GB 15K SAS 12Gb Hot Swap 512n HDD No 10
7XB7A00023 AULX ThinkSystem 2.5" 900GB 15K SAS 12Gb Hot Swap 512e HDD No 10
2.5-inch hot-swap HDDs - 12 Gb SAS 10K
7XB7A00024 AULY ThinkSystem 2.5" 300GB 10K SAS 12Gb Hot Swap 512n HDD No 10
7XB7A00025 AULZ ThinkSystem 2.5" 600GB 10K SAS 12Gb Hot Swap 512n HDD No 10
7XB7A00026 AUM0 ThinkSystem 2.5" 900GB 10K SAS 12Gb Hot Swap 512n HDD No 10
7XB7A00027 AUM1 ThinkSystem 2.5" 1.2TB 10K SAS 12Gb Hot Swap 512n HDD No 10
7XB7A00028 AUM2 ThinkSystem 2.5" 1.8TB 10K SAS 12Gb Hot Swap 512e HDD No 10
7XB7A00069 B0YS ThinkSystem 2.5" 2.4TB 10K SAS 12Gb Hot Swap 512e HDD No 10
2.5-inch hot-swap HDDs - 12 Gb NL SAS
7XB7A00034 AUM6 ThinkSystem 2.5" 1TB 7.2K SAS 12Gb Hot Swap 512n HDD No 10
7XB7A00035 AUM7 ThinkSystem 2.5" 2TB 7.2K SAS 12Gb Hot Swap 512n HDD No 10
2.5-inch hot-swap SED HDDs - 12 Gb SAS 10K
7XB7A00030 AUM4 ThinkSystem 2.5" 300GB 10K SAS 12Gb Hot Swap 512n HDD SED Support 10
Table 23. 2.5-inch hot-swap 6 Gb SATA HDDs
Part number Feature
code
Description SED
support
Max
Qty
2.5-inch hot-swap HDDs - 6 Gb NL SATA
7XB7A00036 AUUE ThinkSystem 2.5" 1TB 7.2K SATA 6Gb Hot Swap 512n HDD No 10
7XB7A00037 AUUJ ThinkSystem 2.5" 2TB 7.2K SATA 6Gb Hot Swap 512e HDD No 10
Table 24. 2.5-inch hot-swap 6 Gb SATA SSDs
Part number Feature
code
Description SED
support
Max
Qty
2.5-inch hot-swap SSDs - 6 Gb SATA - Mixed Use/Mainstream (3-5 DWPD)
4XB7A82289 BQ21 ThinkSystem 2.5" 5400 MAX 480GB Mixed Use SATA 6Gb HS SSD Support 10
4XB7A82290 BQ24 ThinkSystem 2.5" 5400 MAX 960GB Mixed Use SATA 6Gb HS SSD Support 10
4XB7A82291 BQ22 ThinkSystem 2.5" 5400 MAX 1.92TB Mixed Use SATA 6Gb HS SSD Support 10
4XB7A82292 BQ23 ThinkSystem 2.5" 5400 MAX 3.84TB Mixed Use SATA 6Gb HS SSD Support 10
4XB7A17125 BA7Q ThinkSystem 2.5" S4620 480GB Mixed Use SATA 6Gb HS SSD No 10
4XB7A17126 BA4T ThinkSystem 2.5" S4620 960GB Mixed Use SATA 6Gb HS SSD No 10
4XB7A17087 B8J1 ThinkSystem 2.5" 5300 240GB Mainstream SATA 6Gb Hot Swap SSD No 10
4XB7A17088 B8HY ThinkSystem 2.5" 5300 480GB Mainstream SATA 6Gb Hot Swap SSD No 10
4XB7A17089 B8J6 ThinkSystem 2.5" 5300 960GB Mainstream SATA 6Gb Hot Swap SSD No 10
4XB7A17090 B8JE ThinkSystem 2.5" 5300 1.92TB Mainstream SATA 6Gb Hot Swap SSD No 10
4XB7A13633 B49L ThinkSystem 2.5" S4610 240GB Mixed Use SATA 6Gb HS SSD No 10
4XB7A13634 B49M ThinkSystem 2.5" S4610 480GB Mixed Use SATA 6Gb HS SSD No 10
4XB7A13635 B49N ThinkSystem 2.5" S4610 960GB Mixed Use SATA 6Gb HS SSD No 10
4XB7A10237 B488 ThinkSystem 2.5" 5200 240GB Mainstream SATA 6Gb Hot Swap SSD No 10
4XB7A10238 B489 ThinkSystem 2.5" 5200 480GB Mainstream SATA 6Gb Hot Swap SSD No 10
4XB7A10239 B48A ThinkSystem 2.5" 5200 960GB Mainstream SATA 6Gb Hot Swap SSD No 10
2.5-inch hot-swap SSDs - 6 Gb SATA - Read Intensive/Entry (<3 DWPD)
4XB7A82258 BQ1Q ThinkSystem 2.5" 5400 PRO 240GB Read Intensive SATA 6Gb HS SSD Support 10
4XB7A82259 BQ1P ThinkSystem 2.5" 5400 PRO 480GB Read Intensive SATA 6Gb HS SSD Support 10
4XB7A82260 BQ1R ThinkSystem 2.5" 5400 PRO 960GB Read Intensive SATA 6Gb HS SSD Support 10
4XB7A82261 BQ1X ThinkSystem 2.5" 5400 PRO 1.92TB Read Intensive SATA 6Gb HS SSD Support 10
4XB7A82262 BQ1S ThinkSystem 2.5" 5400 PRO 3.84TB Read Intensive SATA 6Gb HS SSD Support 10
4XB7A82263 BQ1T ThinkSystem 2.5" 5400 PRO 7.68TB Read Intensive SATA 6Gb HS SSD Support 10
4XB7A72438 BM8B ThinkSystem 2.5" PM893 480GB Read Intensive SATA 6Gb HS SSD No 10
4XB7A72439 BM8A ThinkSystem 2.5" PM893 960GB Read Intensive SATA 6Gb HS SSD No 10
4XB7A72440 BM89 ThinkSystem 2.5" PM893 1.92TB Read Intensive SATA 6Gb HS SSD No 10
4XB7A72441 BM88 ThinkSystem 2.5" PM893 3.84TB Read Intensive SATA 6Gb HS SSD No 10
4XB7A72442 BM87 ThinkSystem 2.5" PM893 7.68TB Read Intensive SATA 6Gb HS SSD No 10
4XB7A17072 B99D ThinkSystem 2.5" S4520 240GB Read Intensive SATA 6Gb HS SSD No 10
4XB7A17101 BA7G ThinkSystem 2.5" S4520 480GB Read Intensive SATA 6Gb HS SSD No 10
4XB7A17102 BA7H ThinkSystem 2.5" S4520 960GB Read Intensive SATA 6Gb HS SSD No 10
4XB7A38271 BCTC ThinkSystem 2.5" Multi Vendor 240GB Entry SATA 6Gb Hot Swap SSD No 10
4XB7A38272 BCTD ThinkSystem 2.5" Multi Vendor 480GB Entry SATA 6Gb Hot Swap SSD No 10
4XB7A38273 BCTE ThinkSystem 2.5" Multi Vendor 960GB Entry SATA 6Gb Hot Swap SSD No 10
4XB7A38274 BCTF ThinkSystem 2.5" Multi Vendor 1.92TB Entry SATA 6Gb Hot Swap SSD No 10
4XB7A38275 BCTG ThinkSystem 2.5" Multi Vendor 3.84TB Entry SATA 6Gb Hot Swap SSD No 10
4XB7A17075 B8HV ThinkSystem 2.5" 5300 240GB Entry SATA 6Gb Hot Swap SSD No 10
4XB7A17076 B8JM ThinkSystem 2.5" 5300 480GB Entry SATA 6Gb Hot Swap SSD No 10
4XB7A17077 B8HP ThinkSystem 2.5" 5300 960GB Entry SATA 6Gb Hot Swap SSD No 10
4XB7A17078 B8J5 ThinkSystem 2.5" 5300 1.92TB Entry SATA 6Gb Hot Swap SSD No 10
4XB7A17079 B8JP ThinkSystem 2.5" 5300 3.84TB Entry SATA 6Gb Hot Swap SSD No 10
4XB7A38185 B9AC ThinkSystem 2.5" 5210 960GB Entry SATA 6Gb Hot Swap QLC SSD No 10
4XB7A10247 B498 ThinkSystem 2.5" S4510 240GB Read Intensive SATA 6Gb HS SSD No 10
4XB7A10248 B499 ThinkSystem 2.5" S4510 480GB Read Intensive SATA 6Gb HS SSD No 10
4XB7A10249 B49A ThinkSystem 2.5" S4510 960GB Read Intensive SATA 6Gb HS SSD No 10
4XB7A10195 B34H ThinkSystem 2.5" PM883 240GB Entry SATA 6Gb Hot Swap SSD No 10
4XB7A10196 B34J ThinkSystem 2.5" PM883 480GB Entry SATA 6Gb Hot Swap SSD No 10
4XB7A10197 B34K ThinkSystem 2.5" PM883 960GB Entry SATA 6Gb Hot Swap SSD No 10
4XB7A10153 B2X2 ThinkSystem 2.5" 5200 480GB Entry SATA 6Gb Hot Swap SSD No 10
4XB7A10154 B2X3 ThinkSystem 2.5" 5200 960GB Entry SATA 6Gb Hot Swap SSD No 10
Table 25. 2.5-inch hot-swap PCIe 4.0 NVMe SSDs
Part number Feature
code
Description SED
support
Max
Qty
2.5-inch SSDs - U.2 PCIe 4.0 NVMe - Read Intensive/Entry (<3 DWPD)
4XB7A13941 BMGD ThinkSystem 2.5" U.2 P5520 1.92TB Read Intensive NVMe PCIe 4.0 x4 HS SSD Support 2
4XB7A17145 BCFT ThinkSystem 2.5" U.2 P5500 1.92TB Read Intensive NVMe PCIe 4.0 x4 HS SSD No 2

Note: NVMe PCIe SSDs support surprise hot removal and hot insertion, provided the operating system supports PCIe SSD hot-swap.

Table 26. 2.5-inch hot-swap PCIe 3.0 NVMe SSDs
Part number Feature
code
Description SED
support
Max
Qty
2.5-inch SSDs - U.2 PCIe 3.0 NVMe - Read Intensive/Entry (<3 DWPD)
4XB7A10202 B58F ThinkSystem U.2 Intel P4510 1.0TB Entry NVMe PCIe3.0 x4 Hot Swap SSD No 2
7SD7A05779 B11C ThinkSystem U.2 Intel P4500 1.0TB Entry NVMe PCIe3.0 x4 Hot Swap SSD No 2

Note: NVMe PCIe SSDs support surprise hot removal and hot insertion, provided the operating system supports PCIe SSD hot-swap.

Table 27. 3.5-inch hot-swap 12 Gb SAS HDDs
Part number Feature
code
Description SED
support
Max
Qty
3.5-inch hot-swap HDDs - 12 Gb SAS 15K
7XB7A00038 AUU2 ThinkSystem 3.5" 300GB 15K SAS 12Gb Hot Swap 512n HDD No 4
7XB7A00039 AUU3 ThinkSystem 3.5" 600GB 15K SAS 12Gb Hot Swap 512n HDD No 4
7XB7A00040 AUUC ThinkSystem 3.5" 900GB 15K SAS 12Gb Hot Swap 512e HDD No 4
3.5-inch hot-swap HDDs - 12 Gb NL SAS
7XB7A00041 AUU4 ThinkSystem 3.5" 1TB 7.2K SAS 12Gb Hot Swap 512n HDD No 4
7XB7A00042 AUU5 ThinkSystem 3.5" 2TB 7.2K SAS 12Gb Hot Swap 512n HDD No 4
7XB7A00043 AUU6 ThinkSystem 3.5" 4TB 7.2K SAS 12Gb Hot Swap 512n HDD No 4
7XB7A00044 AUU7 ThinkSystem 3.5" 6TB 7.2K SAS 12Gb Hot Swap 512e HDD No 4
7XB7A00045 B0YR ThinkSystem 3.5" 8TB 7.2K SAS 12Gb Hot Swap 512e HDD No 4
7XB7A00067 B117 ThinkSystem 3.5" 12TB 7.2K SAS 12Gb Hot Swap 512e HDD No 4
4XB7A13911 B7EZ ThinkSystem 3.5" 16TB 7.2K SAS 12Gb Hot Swap 512e HDD No 4
4XB7A38266 BCFP ThinkSystem 3.5" 18TB 7.2K SAS 12Gb Hot Swap 512e HDD No 4
4XB7A80353 BPKU ThinkSystem 3.5" 20TB 7.2K SAS 12Gb Hot Swap 512e HDD No 4
Table 28. 3.5-inch hot-swap 6 Gb SATA HDDs
Part number Feature
code
Description SED
support
Max
Qty
3.5-inch hot-swap HDDs - 6 Gb NL SATA
7XB7A00049 AUUF ThinkSystem 3.5" 1TB 7.2K SATA 6Gb Hot Swap 512n HDD No 4
7XB7A00050 AUUD ThinkSystem 3.5" 2TB 7.2K SATA 6Gb Hot Swap 512n HDD No 4
7XB7A00051 AUU8 ThinkSystem 3.5" 4TB 7.2K SATA 6Gb Hot Swap 512n HDD No 4
7XB7A00052 AUUA ThinkSystem 3.5" 6TB 7.2K SATA 6Gb Hot Swap 512e HDD No 4
7XB7A00053 AUU9 ThinkSystem 3.5" 8TB 7.2K SATA 6Gb Hot Swap 512e HDD No 4
7XB7A00068 B118 ThinkSystem 3.5" 12TB 7.2K SATA 6Gb Hot Swap 512e HDD No 4
4XB7A13914 B7F0 ThinkSystem 3.5" 16TB 7.2K SATA 6Gb Hot Swap 512e HDD No 4
4XB7A38130 BCFH ThinkSystem 3.5" 18TB 7.2K SATA 6Gb Hot Swap 512e HDD No 4
4XB7A80354 BPKV ThinkSystem 3.5" 20TB 7.2K SATA 6Gb Hot Swap 512e HDD No 4
Table 29. 3.5-inch hot-swap 6 Gb SATA SSDs
Part number Feature
code
Description SED
support
Max
Qty
3.5-inch hot-swap SSDs - 6 Gb SATA - Mixed Use/Mainstream (3-5 DWPD)
4XB7A17137 BA4W ThinkSystem 3.5" S4620 480GB Mixed Use SATA 6Gb HS SSD No 4
4XB7A17138 BA4X ThinkSystem 3.5" S4620 960GB Mixed Use SATA 6Gb HS SSD No 4
4XB7A17096 B8JL ThinkSystem 3.5" 5300 240GB Mainstream SATA 6Gb Hot Swap SSD No 4
4XB7A17097 B8JF ThinkSystem 3.5" 5300 480GB Mainstream SATA 6Gb Hot Swap SSD No 4
4XB7A17098 B8J0 ThinkSystem 3.5" 5300 960GB Mainstream SATA 6Gb Hot Swap SSD No 4
4XB7A17099 B8HR ThinkSystem 3.5" 5300 1.92TB Mainstream SATA 6Gb Hot Swap SSD No 4
4XB7A13639 B49R ThinkSystem 3.5" S4610 240GB Mixed Use SATA 6Gb HS SSD No 4
4XB7A13640 B49S ThinkSystem 3.5" S4610 480GB Mixed Use SATA 6Gb HS SSD No 4
4XB7A13641 B49T ThinkSystem 3.5" S4610 960GB Mixed Use SATA 6Gb HS SSD No 4
4XB7A10242 B48D ThinkSystem 3.5" 5200 240GB Mainstream SATA 6Gb Hot Swap SSD No 4
4XB7A10243 B48E ThinkSystem 3.5" 5200 480GB Mainstream SATA 6Gb Hot Swap SSD No 4
4XB7A10244 B48F ThinkSystem 3.5" 5200 960GB Mainstream SATA 6Gb Hot Swap SSD No 4
3.5-inch hot-swap SSDs - 6 Gb SATA - Read Intensive/Entry (<3 DWPD)
4XB7A17118 BA7K ThinkSystem 3.5" S4520 240GB Read Intensive SATA 6Gb HS SSD No 4
4XB7A17119 BA7L ThinkSystem 3.5" S4520 480GB Read Intensive SATA 6Gb HS SSD No 4
4XB7A17120 BA7M ThinkSystem 3.5" S4520 960GB Read Intensive SATA 6Gb HS SSD No 4
4XB7A38276 BCTH ThinkSystem 3.5" Multi Vendor 240GB Entry SATA 6Gb Hot Swap SSD No 4
4XB7A38277 BCTJ ThinkSystem 3.5" Multi Vendor 480GB Entry SATA 6Gb Hot Swap SSD No 4
4XB7A38278 BCTK ThinkSystem 3.5" Multi Vendor 960GB Entry SATA 6Gb Hot Swap SSD No 4
4XB7A38279 BCTL ThinkSystem 3.5" Multi Vendor 1.92TB Entry SATA 6Gb Hot Swap SSD No 4
4XB7A38281 BCTM ThinkSystem 3.5" Multi Vendor 3.84TB Entry SATA 6Gb Hot Swap SSD No 4
4XB7A17081 B8JB ThinkSystem 3.5" 5300 240GB Entry SATA 6Gb Hot Swap SSD No 4
4XB7A17082 B8J9 ThinkSystem 3.5" 5300 480GB Entry SATA 6Gb Hot Swap SSD No 4
4XB7A17083 B8JC ThinkSystem 3.5" 5300 960GB Entry SATA 6Gb Hot Swap SSD No 4
4XB7A17084 B8HZ ThinkSystem 3.5" 5300 1.92TB Entry SATA 6Gb Hot Swap SSD No 4
4XB7A17085 B8HQ ThinkSystem 3.5" 5300 3.84TB Entry SATA 6Gb Hot Swap SSD No 4
4XB7A13625 B49D ThinkSystem 3.5" S4510 240GB Read Intensive SATA 6Gb HS SSD No 4
4XB7A13626 B49E ThinkSystem 3.5" S4510 480GB Read Intensive SATA 6Gb HS SSD No 4
4XB7A13627 B49F ThinkSystem 3.5" S4510 960GB Read Intensive SATA 6Gb HS SSD No 4
4XB7A17176 B6TM ThinkSystem 3.5" PM883 240GB Entry SATA 6Gb Hot Swap SSD No 4
4XB7A17177 B6TN ThinkSystem 3.5" PM883 480GB Entry SATA 6Gb Hot Swap SSD No 4
4XB7A17179 B6JY ThinkSystem 3.5" PM883 1.92TB Entry SATA 6Gb Hot Swap SSD No 4
4XB7A10158 B2X7 ThinkSystem 3.5" 5200 480GB Entry SATA 6Gb Hot Swap SSD No 4
4XB7A10159 B2X8 ThinkSystem 3.5" 5200 960GB Entry SATA 6Gb Hot Swap SSD No 4
Table 30. 3.5-inch simple-swap 6 Gb SATA HDDs
Part number Feature
code
Description SED
support
Max
Qty
3.5-inch simple-swap HDDs - 6 Gb NL SATA
7XB7A00055 AUZS ThinkSystem 1TB 7.2K 6Gbps SATA 3.5" Simple Swap 512n HDD No 4
7XB7A00056 AUZT ThinkSystem 2TB 7.2K 6Gbps SATA 3.5" Simple Swap 512n HDD No 4
7XB7A00057 AUZU ThinkSystem 4TB 7.2K 6Gbps SATA 3.5" Simple Swap 512n HDD No 4
7XB7A00058 AXC7 ThinkSystem 6TB 7.2K 6Gbps SATA 3.5" Simple Swap 512e HDD No 4
7XB7A00059 AXC6 ThinkSystem 8TB 7.2K 6Gbps SATA 3.5" Simple Swap 512e HDD No 4
Table 31. 3.5-inch simple-swap 6 Gb SATA SSDs
Part number Feature
code
Description SED
support
Max
Qty
3.5-inch simple-swap SSDs - 6 Gb SATA - Mixed Use/Mainstream (3-5 DWPD)
4XB7A17134 BK7M ThinkSystem 3.5" S4620 480GB Mixed Use SATA 6Gb SS SSD No 4
4XB7A17135 BK7N ThinkSystem 3.5" S4620 960GB Mixed Use SATA 6Gb SS SSD No 4
4XB7A13960 B5Y5 ThinkSystem 3.5" S4610 240GB Mixed Use SATA 6Gb SS SSD No 4
4XB7A13961 B5Y6 ThinkSystem 3.5" S4610 480GB Mixed Use SATA 6Gb SS SSD No 4
4XB7A13962 B5Y7 ThinkSystem 3.5" S4610 960GB Mixed Use SATA 6Gb SS SSD No 4
4XB7A14052 B5Y8 ThinkSystem 3.5" 5200 240GB Mainstream SATA 6Gb Simple Swap SSD No 4
4XB7A14053 B5Y9 ThinkSystem 3.5" 5200 480GB Mainstream SATA 6Gb Simple Swap SSD No 4
4XB7A14054 B5YA ThinkSystem 3.5" 5200 960GB Mainstream SATA 6Gb Simple Swap SSD No 4
3.5-inch simple-swap SSDs - 6 Gb SATA - Read Intensive/Entry (<3 DWPD)
4XB7A17109 BK7C ThinkSystem 3.5" S4520 240GB Read Intensive SATA 6Gb SS SSD No 4
4XB7A17110 BK7D ThinkSystem 3.5" S4520 480GB Read Intensive SATA 6Gb SS SSD No 4
4XB7A17111 BK7E ThinkSystem 3.5" S4520 960GB Read Intensive SATA 6Gb SS SSD No 4
4XB7A08515 B5Y3 ThinkSystem 3.5" 5200 480GB Entry SATA 6Gb Simple Swap SSD No 4
4XB7A10151 B5Y4 ThinkSystem 3.5" 5200 960GB Entry SATA 6Gb Simple Swap SSD No 4
4XB7A13951 B4KE ThinkSystem 3.5" Intel S4510 240GB Entry SATA 6Gb Simple Swap SSD No 4
4XB7A13952 B4KC ThinkSystem 3.5" Intel S4510 480GB Entry SATA 6Gb Simple Swap SSD No 4
4XB7A13953 B4KD ThinkSystem 3.5" Intel S4510 960GB Entry SATA 6Gb Simple Swap SSD No 4
Table 32. M.2 SATA drives
Part number Feature
code
Description SED
support
Max
Qty
M.2 SSDs - 6 Gb SATA - Read Intensive/Entry (<3 DWPD)
4XB7A82286 BQ1Z ThinkSystem M.2 5400 PRO 240GB Read Intensive SATA 6Gb NHS SSD Support 1
4XB7A82287 BQ1Y ThinkSystem M.2 5400 PRO 480GB Read Intensive SATA 6Gb NHS SSD Support 1
4XB7A82288 BQ20 ThinkSystem M.2 5400 PRO 960GB Read Intensive SATA 6Gb NHS SSD Support 1
7N47A00129 AUUL ThinkSystem M.2 32GB SATA 6Gbps Non-Hot Swap SSD No 1
7N47A00130 AUUV ThinkSystem M.2 128GB SATA 6Gbps Non-Hot Swap SSD No 1
4XB7A14049 B5S4 ThinkSystem M.2 5100 240GB SATA 6Gbps Non-Hot Swap SSD No 1
7SD7A05703 B11V ThinkSystem M.2 5100 480GB SATA 6Gbps Non-Hot Swap SSD No 1
4XB7A17071 B8HS ThinkSystem M.2 5300 240GB SATA 6Gbps Non-Hot Swap SSD No 1
4XB7A17073 B919 ThinkSystem M.2 5300 480GB SATA 6Gbps Non-Hot Swap SSD No 1

USB flash drive

For general portable storage needs, the server also supports the USB flash drive option that is listed in the following table.

Table 33. USB memory key
Part number Feature Description
4X77A08621 B8NV ThinkSystem 32GB USB Flash Drive

Optical drives

The server supports the external USB optical drive listed in the following table.

Table 34. External optical drive
Part number Feature code Description
7XA7A05926 AVV8 ThinkSystem External USB DVD RW Optical Disk Drive

The drive is based on the Lenovo Slim DVD Burner DB65 drive and supports the following formats: DVD-RAM, DVD-RW, DVD+RW, DVD+R, DVD-R, DVD-ROM, DVD-R DL, CD-RW, CD-R, CD-ROM.

I/O expansion

The SR250 server supports up to three PCIe slots: one slot on the system planar that supports an internal storage controller and up to two PCIe slots on a riser card.

The slot form factors are as follows:

  • Slot 1: PCIe 3.0 x8; low profile (not present if the Slot 2 is x16)
  • Slot 2: PCIe 3.0 x8 (x16 physical connector) or x16; full-height, half-length
  • Slot 3 PCIe 3.0 x4 (x8 physical connector; supports an internal storage controller)

The locations of the PCIe slots are shown in the following figure.

Slot locations
Figure 8. Slot locations

The following table lists available PCIe riser card options.

Table 35. PCIe riser cards
Description Part number Feature code Maximum quantity
ThinkSystem SR250/SR150 PCIe x16/x8 Riser 4C57A12111 B418 1
ThinkSystem SR250 PCIe x16 Riser 4C57A12110 B417 1

Configuration notes:

  • A riser card is required.
  • The PCIe x8 riser card supplies slots 1 and 2, and the PCIe x16 riser card supplies slot 2.

Network adapters

The SR250 server supports two onboard Gigabit Ethernet network ports that are based on the Broadcom BCM5720 network interface controller (NIC) chip.

The integrated NIC has the following features:

  • Two 10/100/1000 Mb Ethernet RJ-45 ports
  • NIC Teaming (load balancing and failover)
  • IEEE 802.3ad Link Aggregation
  • I/O Virtualization (IOV) for VMWare NetQueue and Microsoft VMQ
  • IEEE 802.1Q Virtual Local Area Networks (VLANs)
  • IEEE 802.3x flow control
  • TCP, IP, and UDP checksum offload
  • Large Send Offload (LSO) and TCP Segmentation Offload (TSO)
  • Receive Side Scaling (RSS) and Transmit Side Scaling (TSS)
  • Jumbo frames up to 9600 bytes
  • IEEE 802.3az-2010 Energy Efficient Ethernet (EEE) compliant
  • Hardware assist for IEEE 1588 and IEEE 802.1AS time synchronization implementations
  • Preboot eXecution Environment (PXE) and iSCSI remote boot options

The following table lists the network adapters that are supported with the SR250 server.

Table 36. Network adapters
Part number Feature code Description Maximum
quantity
I/O slots supported
PCIe Low Profile adapters - 1 Gb Ethernet
7ZT7A00482 AUZX Broadcom 5720 1GbE RJ45 2-Port PCIe Ethernet Adapter 2 1, 2
7ZT7A00484 AUZV Broadcom 5719 1GbE RJ45 4-Port PCIe Ethernet Adapter 1 2
7ZT7A00533 AUZZ ThinkSystem I350-F1 PCIe 1Gb 1-Port SFP Ethernet Adapter 2 1, 2
7ZT7A00534 AUZY ThinkSystem I350-T2 PCIe 1Gb 2-Port RJ45 Ethernet Adapter 2 1, 2
7ZT7A00535 AUZW ThinkSystem I350-T4 PCIe 1Gb 4-Port RJ45 Ethernet Adapter 1 2
PCIe Low Profile adapters - 10 Gb Ethernet
7ZT7A00496 AUKP Broadcom 57416 10GBASE-T 2-Port PCIe Ethernet Adapter 2 1, 2
00AG570 AT7S Emulex VFA5.2 2x10 GbE SFP+ PCIe Adapter 2* 1, 2
00AG580 AT7T Emulex VFA5.2 2x10 GbE SFP+ Adapter and FCoE/iSCSI SW 2* 1, 2
00MM850 ATRY Intel X550-T1 Single Port 10GBase-T Adapter 2 1, 2
00MM860 ATPX Intel X550-T2 Dual Port 10GBase-T Adapter 2 1, 2
7ZT7A00537 AUKX Intel X710-DA2 PCIe 10Gb 2-Port SFP+ Ethernet Adapter 2* 1, 2
7XC7A05927 B0X1 Intel X710-T4 PCIe 10Gb 4-Port Base-T Adapter 1 2
4XC7A08225 B31G QLogic QL41134 PCIe 10Gb 4-Port Base-T Ethernet Adapter 1 2
PCIe Full Height adapters - 10 Gb Ethernet
7ZT7A00493 AUKN Emulex OCe14104B-NX PCIe 10Gb 4-Port SFP+ Ethernet Adapter 1* 2
7XC7A05525 B0YL Intel X710-DA4 PCIe 10Gb 4-Port SFP+ Ethernet Adapter 1* 2
PCIe Low Profile adapters - 25 Gb Ethernet
7ZT7A00505 AUKS Broadcom 57412 10/25GbE SFP28 1-Port PCIe Ethernet Adapter 2* 1, 2
7XC7A05523 B0WY Intel XXV710-DA2 10/25GbE SFP28 2-Port PCIe Ethernet Adapter 2* 1, 2
01GR250 AUAJ Mellanox ConnectX-4 Lx 10/25GbE SFP28 2-Port PCIe Eth. Adapter 2* 1, 2
4XC7A08228 B21R QLogic QL41262 10/25GbE SFP28 2-Port PCIe Ethernet Adapter 2* 1, 2

* The adapter comes without transceivers or cables; for ordering information, see the adapter product guide.

Configuration notes:

  • PCIe full-height network adapters are supported in the full-height PCIe slot 2 supplied by the PCIe x8 or x16 riser card.
  • PCIe Low Profile network adapters are supported in the full-height and low profile slots supplied by the PCIe x8 or x16 riser card.
  • Supported transceivers or DAC cables should be purchased for the SFP+ and SFP28 adapters, and UTP Category 6 or Category 5e cables should be purchased for the 10 GbE (Cat6) or 1 GbE (Cat5e or Cat6) RJ-45 adapters. The maximum number of transceivers or cables that are supported per adapter equals the quantity of the adapter ports, and all adapter ports must have the same type of the transceiver or cable selected.

For more information, see the list of Product Guides in the Ethernet Adapters category:
http://lenovopress.com/servers/options/ethernet#rt=product-guide

SAS adapters for external storage

The following table lists SAS RAID controllers and HBAs for external storage attachments that are supported by the SR250 server.

Table 37. SAS RAID adapters and HBAs for external storage
Description Part number Feature code Maximum quantity I/O slots supported
12 Gbps SAS RAID adapters
ThinkSystem RAID 930-8e 4GB Flash PCIe 12Gb Adapter 7Y37A01087 AUNQ 1 1, 2
12 Gbps SAS HBAs
ThinkSystem 430-8e SAS/SATA 12Gb HBA 7Y37A01090 AUNR 1 1, 2
ThinkSystem 430-16e SAS/SATA 12Gb HBA 7Y37A01091 AUNN 1 1, 2

Configuration notes:

  • Low profile SAS RAID controllers and HBAs for external storage are supported in the low profile and full-high PCIe slots supplied by the x8 or x16 riser card.
  • The total quantity of the RAID 730-8i 2GB, 930-8i, 930-16i, and 930-8e controllers in the server must not exceed 1 (up to 1 supercapacitor can be mounted in the server).

Mixing storage adapter families: The following HBA/RAID adapter combinations are supported:

  • X30 external adapters with other X30 adapters (internal or external)
  • X40 external adapters with other X40 adapters (internal or external)
  • X40 external adapters with X350 internal adapters

The following HBA/RAID adapter combinations are not supported:

  • X30 adapters (internal or external) with X40 adapters (internal or external)
  • X30 adapters (internal or external) with X350 internal adapters

The following table summarizes features of supported RAID controllers and HBAs for external storage.

Table 38. Features and specifications of the RAID controllers and HBAs for external storage
Feature RAID 930-8e 430-8e HBA 430-16e HBA
Form factor PCIe LP PCIe LP PCIe LP
SAS controller chip SAS3516 SAS3408 SAS3416
Host interface PCIe 3.0 x8 PCIe 3.0 x8 PCIe 3.0 x8
Port interface 12 Gb SAS 12 Gb SAS 12 Gb SAS
Number of ports 8 8 16
Connector type SFF-8644 x4 SFF-8644 x4 SFF-8644 x4
Number of connectors 2 2 4
Drive interface SAS, SATA SAS, SATA SAS, SATA
Drive type HDD, SSD, SED HDD, SSD, SED* HDD, SSD, SED*
Hot-swap drive support Yes Yes Yes
Number of devices 240 1024 1024
RAID levels 0/1/10/5/50/6/60 None None
JBOD mode Yes Yes Yes
Cache 4 GB None None
Cache protection Flash backup (Included) None None
SED key management (SafeStore) Yes No No
SSD I/O acceleration (FastPath) Yes No No
SSD Caching (CacheCade Pro 2.0) No** No No
Consistency check Yes No No
Patrol read Yes No No
Online capacity expansion Yes No No
Online RAID level migration Yes No No
Global Hot Spare Yes No No
Auto-rebuild Yes No No

* HBAs do not support key management for SEDs; third-party host software is responsible for managing the keys.
** The SSD caching feature has been phased out in the new generation of advanced RAID controllers.

For more information, see the list of Product Guides in the following categories:

Fibre Channel host bus adapters

The following table lists Fibre Channel HBAs supported by the SR250 server.

Table 39. Fibre Channel HBAs
Description Part number Feature code Maximum quantity I/O slots supported
Emulex 16Gb Gen6 FC Single-port HBA 01CV830 ATZU 2 1, 2
Emulex 16Gb Gen6 FC Dual-port HBA 01CV840 ATZV 2 1, 2

Configuration note: FC HBAs are supported in the low profile and full-high PCIe slots supplied by the PCIe x8 or x16 riser card.

For more information, see the list of Product Guides in the Host bus adapters category:
http://lenovopress.com/servers/options/hba#rt=product-guide

GPU adapters

The SR250 does not support any GPUs that are currently available.

The SR250 server supports graphics processing unit (GPU) adapters listed in the following table.

Table 40. GPU adapters
Description Part number Feature code Maximum quantity I/O slots supported
ThinkSystem NVIDIA Quadro P620 2GB PCIe Active GPU (PCIe 3.0 x16) 4X67A11584 B31D 1 2

Configuration notes:

  • The GPU adapters are supported only in the configurations with 450 W hot-swap power supplies.
  • The GPU adapters are supported in the PCIe slot 2 supplied by the PCIe x8 or x16 riser card.

Cooling

The SR250 server ships with four non-hot-swap system fans.

Configuration note: The server performance might be impacted in case of a system fan failure.

Power supplies and cables

The SR250 server supports one fixed power supply or up to two redundant hot-swap power supplies. With two power supplies, the server is capable of N+N redundancy depending on the configuration. A second power supply can be added to the models that come with one hot-swap power supply.

The following table lists the power supply options.

Table 41. Power supplies
Description Part number Feature code Maximum quantity
ThinkSystem SR250/SR150 Fixed 300W Power Supply None* B40Q 1
ThinkSystem 450W (230V/115V) Platinum Hot-Swap Power Supply 4P57A12649 B40R 2
ThinkSystem 450W (230V/115V) Platinum Hot-Swap Power Supply India 4P57A16264 B5LC 2

* Factory-installed only.

Configuration notes:

  • Configurations with 300 W fixed power supplies (feature code B40Q) are supported only for Machine Types 7Y51, 7Y52, and 7Y73.
  • Configurations with 450 W hot-swap power supplies (4P57A12649) that are available worldwide (except India) are supported only for Machine Types 7Y51 and 7Y52.
  • Configurations with 450 W hot-swap power supplies for India (4P57A16264) are supported only for Machine Type 7Y72.
  • To ensures that the properly sized power supply is chosen for optimal performance, it is highly recommended to validate system configuration for specific power requirements by using the latest version of the Lenovo Capacity Planner:
    http://datacentersupport.lenovo.com/us/en/solutions/lnvo-lcp

The SR250 server ship standard with or without a power cord (model dependent). A hot-swap power supply option ships without a power cord.

The following table lists the line cords and rack power cables that can be ordered for the SR250 server. One or two power cables can be ordered, depending on the quantity of power supplies in the server.

Table 42. Power cables
Description Part number Feature code
Rack power cables
1.0m, 10A/100-250V, C13 to IEC 320-C14 Rack Power Cable 00Y3043 A4VP
1.5m, 10A/100-250V, C13 to IEC 320-C14 Rack Power Cable 39Y7937 6201
2.0m, 10A/100-250V, C13 to IEC 320-C14 Rack Power Cable 4L67A08365 B0N4
2.0m, 13A/125V-10A/250V, C13 to IEC 320-C14 Rack Power Cable 4L67A08369 6570
2.8m, 10A/100-250V, C13 to IEC 320-C14 Rack Power Cable 4L67A08366 6311
2.8m, 13A/125V-10A/250V, C13 to IEC 320-C14 Rack Power Cable 4L67A08370 6400
2.8m, 10A/100-250V, C13 to IEC 320-C20 Rack Power Cable 39Y7938 6204
4.3m, 10A/100-250V, C13 to IEC 320-C14 Rack Power Cable 39Y7932 6263
4.3m, 13A/125V-10A/250V, C13 to IEC 320-C14 Rack Power Cable 4L67A08371 6583
Line cords
2.8m, 10A/125V, C13 to CNS 10917-3 Line Cord 23R7158 6386
2.8m, 10A/125V, C13 to NEMA 5-15P Line Cord 90Y3016 6313
2.8m, 10A/250V, C13 to AS/NZS 3112 Line Cord 39Y7924 6211
2.8m, 10A/250V, C13 to BS 1363/A Line Cord 39Y7923 6215
2.8m, 10A/250V, C13 to CEE7-VII Line Cord 39Y7917 6212
2.8m, 10A/250V, C13 to CEI 23-16 Line Cord 39Y7921 6217
2.8m, 10A/250V, C13 to CNS 10917-3 Line Cord 81Y2375 6317
2.8m, 10A/250V, C13 to DK2-5a Line Cord 39Y7918 6213
2.8m, 10A/250V, C13 to GB 2099.1 Line Cord 39Y7928 6210
2.8m, 10A/250V, C13 to IRAM 2073 Line Cord 39Y7930 6222
2.8m, 10A/250V, C13 to IS 6538 Line Cord 39Y7927 6269
2.8m, 10A/250V, C13 to NBR 14136 Line Cord 69Y1988 6532
2.8m, 10A/250V, C13 to NEMA 6-15P Line Cord 46M2592 A1RF
2.8m, 10A/250V, C13 to SABS 164 Line Cord 39Y7922 6214
2.8m, 10A/250V, C13 to SEV 1011-S24507 Line Cord 39Y7919 6216
2.8m, 10A/250V, C13 to SI 32 Line Cord 39Y7920 6218
2.8m, 12A/125V, C13 to JIS C-8303 Line cord 46M2593 A1RE
2.8m, 12A/250V, C13 to JIS C-8303 Line Cord 4L67A08357 6533
2.8m, 12A/250V, C13 to KS C8305 Line Cord 39Y7925 6219
4.3m, 10A/125V, C13 to CNS 10917-3 Line Cord 4L67A08363 AX8B
4.3m, 10A/125V, C13 to NEMA 5-15P Line Cord 4L67A08359 6370
4.3m, 10A/250V, C13 to AS/NZS 3112 Line Cord 81Y2383 6574
4.3m, 10A/250V, C13 to BS 1363/A Line Cord 81Y2377 6577
4.3m, 10A/250V, C13 to CEE7-VII Line Cord 81Y2376 6572
4.3m, 10A/250V, C13 to CEI 23-16 Line Cord 81Y2380 6493
4.3m, 10A/250V, C13 to CNS 10917-3 Line Cord 81Y2389 6531
4.3m, 10A/250V, C13 to DK2-5a Line Cord 81Y2382 6575
4.3m, 10A/250V, C13 to GB 2099.1 Line Cord 81Y2378 6580
4.3m, 10A/250V, C13 to IRAM 2073 Line Cord 81Y2384 6492
4.3m, 10A/250V, C13 to IS 6538 Line Cord 81Y2386 6567
4.3m, 10A/250V, C13 to NBR14136 Line Cord 81Y2387 6404
4.3m, 10A/250V, C13 to NEMA 6-15P Line Cord 4L67A08361 6373
4.3m, 10A/250V, C13 to SABS 164 Line Cord 81Y2379 6576
4.3m, 10A/250V, C13 to SEV 1011-S24507 Line Cord 81Y2390 6578
4.3m, 10A/250V, C13 to SI 32 Line Cord 81Y2381 6579
4.3m, 12A/125V, C13 to JIS C-8303 Line Cord 39Y7926 6335
4.3m, 12A/250V, C13 to JIS C-8303 Line Cord 4L67A08362 6495
4.3m, 12A/250V, C13 to KS C8305 Line Cord 81Y2385 6494

Systems management

The SR250 supports the following systems management tools:

  • Lenovo XClarity Controller
  • Lenovo XClarity Provisioning Manager
  • Lenovo XClarity Essentials
  • Lenovo XClarity Administrator
  • Lenovo XClarity Integrators
  • Lenovo XClarity Energy Manager
  • Lenovo Capacity Planner

Lenovo XClarity Controller

The SR250 server contains Lenovo XClarity Controller (XCC), which provides advanced service-processor control, monitoring, and alerting functions. XClarity Controller offers three functional levels: Standard, Advanced, and Enterprise.

By default, the SR250 server includes XClarity Controller Standard features, and it can be upgraded to Advanced or Enterprise functionality by using the Features on Demand (FoD) upgrades.

XClarity Controller Standard offers the following capabilities:

  • Gathering and viewing system information and inventory
  • Monitoring system status and health
  • Alerting and notifications
  • Event logging
  • Configuring network connectivity
  • Configuring security
  • Updating system firmware
  • Configuring server settings and devices
  • Real-time power usage monitoring
  • Remotely controlling server power (Power on, Power off, Restart)
  • Managing FoD activation keys
  • Redirecting serial console via IPMI
  • Capturing the video display contents when an operating system hang condition is detected 

XClarity Controller Advanced Upgrade adds the following functionality to the Standard features:

  • Remotely viewing video with the following graphics resolutions:
    • Up to 1600x1200 with up to 23 bits per pixel; or
    • Up to 1920x1200 with up to 15 bits per pixel
  • Remotely accessing the server using the keyboard and mouse from a remote client
  • Remotely deploying an operating system
  • Syslog alerting
  • Redirecting serial console via SSH
  • Displaying graphics for real-time and historical power usage data and temperature

XClarity Controller Enterprise Upgrade adds the following functionality to the Advanced features:

  • Capping power usage
  • Mapping the ISO and image files located on the local client as virtual drives for use by the server
  • Mounting the remote ISO and image files via HTTPS, SFTP, CIFS, and NFS
  • Collaborating across up to six users of the virtual console
  • Controlling quality and bandwidth usage

The XClarity Controller provides remote server management through industry-standard interfaces:

  • Intelligent Platform Management Interface (IPMI) Version 2.0
  • Simple Network Management Protocol (SNMP) Version 3
  • Common Information Model (CIM)
  • Data Center Manageability Interface (DCMI) Version 1.5
  • Redfish REpresentational State Transfer (REST) API
  • Web browser with HTML5 support
  • Command-line interface
  • Virtual Operator Panel with XClarity Mobile App via the front USB port with XClarity Controller access

Virtual Operator Panel provides quick access to system status, firmware, network, health, and alerts information. With proper authentication, it also allows to configure systems management and network settings and to control system power (Power on, Power off, Restart). The Virtual Operator Panel can be accessed from the XClarity Mobile App running on the Android or iOS mobile device that is connected to the front USB port with XClarity Controller access (See Components and connectors).

Note: Depending on the system settings, the front USB port can be assigned to XClarity Controller for management functions, or to the system as a regular USB 2.0 port, or switched between two functions by using the system ID button.

IPMI via the Ethernet port (IPMI over LAN) is supported, however it is disabled by default. For CTO orders you can specify whether you want to the feature enabled or disabled in the factory, using the feature codes listed in the following table.

Table 43. IPMI-over-LAN settings
Part number Feature code Description
CTO only B7XZ Disable IPMI-over-LAN (default)
CTO only B7Y0 Enable IPMI-over-LAN

The following table lists the XClarity Controller FoD upgrades.

Table 44. XClarity Controller FoD upgrades
Description Part number Feature code Maximum quantity
ThinkSystem XClarity Controller Standard to Advanced Upgrade 4L47A09132 AVUT 1
ThinkSystem XClarity Controller Standard to Enterprise Upgrade None* AUPW 1
ThinkSystem XClarity Controller Advanced to Enterprise Upgrade 4L47A09133 None** 1

* Factory-installed only.
** Field-upgrade only.

Configuration notes:

  • For factory-installed upgrades, either Standard to Advanced Upgrade (feature AVUT) or Standard to Enterprise Upgrade (feature AUPW) can be selected, but not both.
  • For field upgrades, the Advanced to Enterprise Upgrade (4L47A09133) requires the Standard to Advanced Upgrade to be activated on the server previously with either the factory-installed feature AVUT or field upgrade 4L47A09132.

Lenovo XClarity Provisioning Manager

Lenovo XClarity Provisioning Manager (LXPM) is a UEFI-based application embedded in ThinkSystem servers and accessible via the F1 key during system boot.

LXPM provides the following functions:

  • Graphical UEFI Setup
  • System inventory information and VPD update
  • System firmware updates (UEFI and XCC)
  • RAID setup wizard
  • OS installation wizard (including unattended OS installation)
  • Diagnostics functions

Lenovo XClarity Essentials

Lenovo offers the following XClarity Essentials software tools that can help you set up, use, and maintain the server at no additional cost:

  • Lenovo Essentials OneCLI

    OneCLI is a collection of server management tools that uses a command line interface program to manage firmware, hardware, and operating systems. It provides functions to collect full system health information (including health status), configure system settings, and update system firmware and drivers.

  • Lenovo Essentials UpdateXpress

    The UpdateXpress tool is a standalone GUI application for firmware and device driver updates that enables you to maintain your server firmware and device drivers up-to-date and help you avoid unnecessary server outages. The tool acquires and deploys individual updates and UpdateXpress System Packs (UXSPs) which are integration-tested bundles.

  • Lenovo Essentials Bootable Media Creator

    The Bootable Media Creator (BOMC) tool is used to create bootable media for offline firmware update.

For more information and downloads, visit the Lenovo XClarity Essentials web page:
http://support.lenovo.com/us/en/documents/LNVO-center

Lenovo XClarity Administrator

Lenovo XClarity Administrator is a centralized resource management solution designed to reduce complexity, speed response, and enhance the availability of Lenovo systems and solutions. It provides agent-free hardware management for ThinkSystem servers, in addition to ThinkServer, System x, and Flex System servers. The administration dashboard is based on HTML 5 and allows fast location of resources so tasks can be run quickly.

Because Lenovo XClarity Administrator does not require any agent software to be installed on the managed endpoints, there are no CPU cycles spent on agent execution, and no memory is used, which means that up to 1GB of RAM and 1 - 2% CPU usage is saved, compared to a typical managed system where an agent is required.

Lenovo XClarity Administrator is an optional software component for the SR250. The software can be downloaded and used at no charge to discover and monitor the SR250 and to manage firmware upgrades.

If software support is required for Lenovo XClarity Administrator, or premium features such as configuration management and operating system deployment are required, Lenovo XClarity Pro software subscription should be ordered. Lenovo XClarity Pro is licensed on a per managed system basis, that is, each managed Lenovo system requires a license.

The following table lists the Lenovo XClarity software license options.

Table 45. Lenovo XClarity Pro ordering information
Part number Feature code Description
00MT201 1339 Lenovo XClarity Pro, per Managed Endpoint w/1 Yr SW S&S
00MT202 1340 Lenovo XClarity Pro, per Managed Endpoint w/3 Yr SW S&S
00MT203 1341 Lenovo XClarity Pro, per Managed Endpoint w/5 Yr SW S&S
7S0X000HWW SAYV Lenovo XClarity Pro, per Managed Endpoint w/6 Yr SW S&S
7S0X000JWW SAYW Lenovo XClarity Pro, per Managed Endpoint w/7 Yr SW S&S

Lenovo XClarity Administrator offers the following standard features that are available at no charge:

  • Auto-discovery and monitoring of Lenovo systems
  • Firmware updates and compliance enforcement
  • External alerts and notifications via SNMP traps, syslog remote logging, and e-mail
  • Secure connections to managed endpoints
  • NIST 800-131A or FIPS 140-2 compliant cryptographic standards between the management solution and managed endpoints
  • Integration into existing higher-level management systems such as cloud automation and orchestration tools through REST APIs, providing extensive external visibility and control over hardware resources
  • An intuitive, easy-to-use GUI
  • Scripting with Windows PowerShell, providing command-line visibility and control over hardware resources

Lenovo XClarity Administrator offers the following premium features that require an optional Pro license:

  • Pattern-based configuration management that allows to define configurations once and apply repeatedly without errors when deploying new servers or redeploying existing servers without disrupting the fabric
  • Bare-metal deployment of operating systems and hypervisors to streamline infrastructure provisioning

For more information, refer to the Lenovo XClarity Administrator Product Guide:
http://lenovopress.com/tips1200

Lenovo XClarity Integrators

Lenovo also offers software plug-in modules, Lenovo XClarity Integrators, to manage physical infrastructure from leading external virtualization management software tools including those from Microsoft and VMware.

These integrators are offered at no charge, however if software support is required, a Lenovo XClarity Pro software subscription license should be ordered.

Lenovo XClarity Integrators offer the following additional features:

  • Ability to discover, manage, and monitor Lenovo server hardware from VMware vCenter or Microsoft System Center
  • Deployment of firmware updates and configuration patterns to Lenovo x86 rack servers and Flex System from the virtualization management tool
  • Non-disruptive server maintenance in clustered environments that reduces workload downtime by dynamically migrating workloads from affected hosts during rolling server updates or reboots
  • Greater service level uptime and assurance in clustered environments during unplanned hardware events by dynamically triggering workload migration from impacted hosts when impending hardware failures are predicted

For more information about all the available Lenovo XClarity Integrators, see the Lenovo XClarity Administrator Product Guide: https://lenovopress.com/tips1200-lenovo-xclarity-administrator

Lenovo XClarity Energy Manager

Lenovo XClarity Energy Manager (LXEM) is a power and temperature management solution for data centers. It is an agent-free, web-based console that enables you to monitor and manage power consumption and temperature in your data center through the management console. It enables server density and data center capacity to be increased through the use of power capping.

LXEM is a licensed product. A single-node LXEM license is included with the XClarity Controller Enterprise upgrade as described in the Remote Management section. If your server does not have the XCC Enterprise upgrade, Energy Manager licenses can be ordered as shown in the following table.

Table 46. Lenovo XClarity Energy Manager
Part number Description
4L40E51621 Lenovo XClarity Energy Manager Node License (1 license needed per server)

For more information about XClarity Energy Manager, see the following resources:

Lenovo Capacity Planner

Lenovo Capacity Planner is a power consumption evaluation tool that enhances data center planning by enabling IT administrators and pre-sales professionals to understand various power characteristics of racks, servers, and other devices. Capacity Planner can dynamically calculate the power consumption, current, British Thermal Unit (BTU), and volt-ampere (VA) rating at the rack level, improving the planning efficiency for large scale deployments.

For more information, refer to the Capacity Planner web page:
http://datacentersupport.lenovo.com/us/en/solutions/lnvo-lcp

Security

The SR250 server offers the following security features:

  • Power-on password
  • Administrator's password
  • Secure firmware updates
  • Onboard Trusted Platform Module (TPM) version 1.2 or 2.0 (configurable UEFI system setting)
  • Nationz Trusted Platform Module v2.0 (optional; PRC only)
  • Lockable front bezel (optional)
  • Self-encrypting drives (SEDs) with support for enterprise key managers - see the SED encryption key management section

The server is NIST SP 800-147B compliant.

The following table lists the security options that are available for the SR250 server.

Table 47. Security options
Description Part number Feature code Maximum quantity
Lockable front bezel
ThinkSystem 1U Security Bezel 7Z17A02581 AUWR 1
Trusted Platform Module (PRC only)
ThinkSystem Nationz Trusted Platform Module v2.0 None* B22N 1

* Factory-installed only; no field upgrade.

Intel Transparent Supply Chain

Add a layer of protection in your data center and have peace of mind that the server hardware you bring into it is safe authentic and with documented, testable, and provable origin.

Lenovo has one of the world’s best supply chains, as ranked by Gartner Group, backed by extensive and mature supply chain security programs that exceed industry norms and US Government standards. Now we are the first Tier 1 manufacturer to offer Intel® Transparent Supply Chain in partnership with Intel, offering you an unprecedented degree of supply chain transparency and assurance.

To enable Intel Transparent Supply Chain for the Intel-based servers in your order, add the following feature code in the DCSC configurator, under the Security tab.

Table 48. Intel Transparent Supply Chain ordering information
Feature code Description
BB0P Intel Transparent Supply Chain

For more information on this offering, see the paper Introduction to Intel Transparent Supply Chain on Lenovo ThinkSystem Servers, available from https://lenovopress.com/lp1434-introduction-to-intel-transparent-supply-chain-on-thinksystem-servers.

Rack installation

The following table lists the rack installation options that are available for the SR250 server.

Table 49. Rack installation options
Part number Feature code Description Maximum quantity
4-post rail kits
4M17A13564 B42B ThinkSystem Tool-less Friction Rail v2 1
4M17A37605 B7L3 ThinkSystem Short Rack Rail Kit 1
2-post rail kits
4M17A37105 B6H2 ThinkSystem Friction 2-Post Screw-in Rail Kit 1
Front VGA port
4Z57A80508 BMQ0 ThinkSystem SR250/SR150/SR250 V2 Front VGA Connector Kit v2 1
4Z57A12653 B419 ThinkSystem SR250/SR150 Front VGA Connector Kit 1

The following table summarizes the rail kit features and specifications.

Table 50. Rail kit features and specifications summary
Feature 4-Post Tool-less Rail Kit 4-Post Short Rail Kit 2-Post Screw-in Rail Kit
Part number 4M17A13564 4M17A37605 4M17A37105
CMA None None None
Rail length 751.2 mm (29.6 in.) 484.0 mm (19.1 in.) 486.2 mm (19.2 in.)
Rail type Half-out slide (friction) Half-out slide (friction) Half-out slide (friction)
Tool-less installation Yes Yes No
In-rack server maintenance No No No
1U PDU support Yes Yes Yes
0U PDU support Limited* Yes Not applicable
Rack type IBM or Lenovo 4-post,
EIA standard-compliant
4-post, EIA
standard-compliant
2-post, EIA
standard-compliant
Mounting holes Square or round Square or round Square, round, or threaded
Mounting flange thickness 2 mm (0.08 in.) –
3.3 mm (0.13 in.)
2 mm (0.08 in.) –
3.3 mm (0.13 in.)
2 mm (0.08 in.) –
3.3 mm (0.13 in.)
Distance between front and rear
mounting flanges^
609.6 mm (24 in.) –
863.6 mm (34 in.)
355.6 mm (14 in.) –
609.6 mm (24 in.)
Not applicable

* If a 0U PDU used, the rack cabinet must be at least 1000 mm (39.37 in.) deep.
^ Measured when mounted on the rack cabinet, from the front surface of the front mounting flange to the rear most point of the rail.

Operating system support

The server supports the following operating systems:

  • Microsoft Windows Server 2016
  • Microsoft Windows Server 2019
  • Microsoft Windows Server 2022
  • Red Hat Enterprise Linux 7.7
  • Red Hat Enterprise Linux 7.8
  • Red Hat Enterprise Linux 7.9
  • Red Hat Enterprise Linux 8.1
  • Red Hat Enterprise Linux 8.2
  • Red Hat Enterprise Linux 8.3
  • Red Hat Enterprise Linux 8.4
  • Red Hat Enterprise Linux 8.5
  • Red Hat Enterprise Linux 8.6
  • Red Hat Enterprise Linux 8.7
  • Red Hat Enterprise Linux 8.8
  • Red Hat Enterprise Linux 8.9
  • Red Hat Enterprise Linux 9.0
  • Red Hat Enterprise Linux 9.1
  • Red Hat Enterprise Linux 9.2
  • Red Hat Enterprise Linux 9.3
  • SUSE Linux Enterprise Server 12 SP5
  • SUSE Linux Enterprise Server 12 Xen SP5
  • SUSE Linux Enterprise Server 15 SP1
  • SUSE Linux Enterprise Server 15 SP2
  • SUSE Linux Enterprise Server 15 SP3
  • SUSE Linux Enterprise Server 15 SP4
  • SUSE Linux Enterprise Server 15 SP5
  • SUSE Linux Enterprise Server 15 Xen SP1
  • SUSE Linux Enterprise Server 15 Xen SP2
  • SUSE Linux Enterprise Server 15 Xen SP3
  • SUSE Linux Enterprise Server 15 Xen SP4
  • SUSE Linux Enterprise Server 15 Xen SP5
  • Ubuntu 22.04 LTS 64-bit
  • VMware ESXi 6.5 U3
  • VMware ESXi 6.7 U3
  • VMware ESXi 7.0
  • VMware ESXi 7.0 U1
  • VMware ESXi 7.0 U2
  • VMware ESXi 7.0 U3
  • VMware ESXi 8.0
  • VMware ESXi 8.0 U1
  • VMware ESXi 8.0 U2

For a complete list of supported, certified and tested operating systems, plus additional details and links to relevant web sites, see the Operating System Interoperability Guide: https://lenovopress.com/osig#servers=sr250-7y51-7y52-e-2200

For configure-to-order configurations, the server can be preloaded with VMware ESXi. Ordering information is listed in the following table.

Table 51. VMware ESXi preload
Part number Feature code Description
CTO only B6U0 VMware ESXi 6.5 U3 (factory installed)
CTO only B88T VMware ESXi 6.7 U3 (factory installed)
CTO only BBZG VMware ESXi 7.0 (Factory Installed)
CTO only BE5E VMware ESXi 7.0 U1 (Factory Installed)
CTO only BHSR VMware ESXi 7.0 U2 (Factory Installed)
CTO only BMEY VMware ESXi 7.0 U3 (Factory Installed)
CTO only BMT5 VMware ESXi 8.0 (Factory Installed)

Physical specifications

The SR250 has the following overall physical dimensions, excluding components that extend outside the standard chassis, such as EIA flanges, front security bezel (if any), and power supply handles:

  • Width: 435 mm (17.1 inches)
  • Height: 43 mm (1.7 inches)
  • Depth: 545 mm (21.5 inches)

The following table lists the detailed dimensions. See the figure below for the definition of each dimension.

Table 52. Detailed dimensions
Dimension Description
482 mm Xa = Width, to the outsides of the front EIA flanges
435 mm Xb = Width, to the rack rail mating surfaces
435 mm Xc = Width, to the outer most chassis body feature
43 mm Ya = Height, from the bottom of chassis to the top of the chassis
501 mm Za = Depth, from the rack flange mating surface to the rearmost I/O port surface
509 mm Zb = Depth, from the rack flange mating surface to the rearmost feature of the chassis body
523 mm Zc = Depth, from the rack flange mating surface to the rearmost feature such as power supply handle
36 mm Zd = Depth, from the forwardmost feature on front of EIA flange to the rack flange mating surface
47 mm Ze = Depth, from the front of security bezel (if applicable) or forwardmost feature to the rack flange mating surface

Rack server dimensions
Figure 9. Server dimensions

The shipping (cardboard packaging) dimensions of the SR250 are as follows:

  • Width: 186 mm (7.3 inches)
  • Height: 879 mm (34.6 inches)
  • Depth: 600 mm (23.6 inches)

The SR250 server has the following weight:

  • Base configuration: 9.1 kg (20.1 lb)
  • Maximum configuration: 12.3 kg (27.1 lb)

Operating environment

The SR250 server complies with ASHRAE class A2 specifications. The server performance might be impacted when the operating temperature is outside the ASHRAE A2 specifications or in case of a system fan failure. Depending on the hardware configuration, some server models comply with ASHRAE class A3 specifications. To comply with ASHRAE class A3 specifications, the SR250 server models must be configured with 8x 2.5-inch hot-swap drive bays and a processor with up to 80 W TDP.

The SR250 server is supported in the following environment:

  • Air temperature:
    • Operating:
      • ASHRAE Class A3: 5 °C - 40 °C (41 °F - 104 °F); for altitudes above 900 m (2,953 ft), decrease the maximum ambient temperature by 1 °C for every 175-m (574-ft) increase in altitude
      • ASHRAE Class A2: 10 °C - 35 °C (50 °F - 95 °F); for altitudes above 900 m (2,953 ft), decrease the maximum ambient temperature by 1 °C for every 300-m (984-ft) increase in altitude
    • Non-operating: 5 °C - 45 °C (41 °F - 113 °F)
    • Storage: -40 °C - +60 °C (-40 °F - 140 °F)
  • Maximum altitude: 3050 m (10,000 ft)
  • Humidity:
    • Operating:
      • ASHRAE Class A3: 8% - 85% (non-condensing); maximum dew point: 24 °C (75 °F)
      • ASHRAE Class A2: 8% - 80% (non-condensing); maximum dew point: 21 °C (70 °F)
    • Storage: 8% - 90% (non-condensing)
  • Electrical:
    • 100 - 127 (nominal) V AC; 50 Hz / 60 Hz
    • 200 - 240 (nominal) V AC; 50 Hz / 60 Hz
  • Acoustics:
    • Minimum configuration:
      • Operating: 5.3 bels
      • Idle: 4.9 bels
    • Maximum configuration:
      • Operating: 5.7 bels
      • Idle: 5.4 bels
  • Vibration:
    • Operating: 0.21 G rms at 5 Hz to 500 Hz for 15 minutes across 3 axes
    • Non-operating: 1.04 G rms at 2 Hz to 200 Hz for 15 minutes across 6 surfaces
  • Shock:
    • Operating: 15 G for 3 milliseconds in each direction (positive and negative X, Y, and Z axes)
    • Non-operating: 50 G for 152 in./sec velocity change across 6 surfaces

The following table lists the maximum system power load, rated inlet current, and system heat output based on the power supply and source voltage.

Table 53. Rated system power, inlet current, and system heat output
Power supply Source voltage Maximum power
load per system
Rated current
per inlet
System
heat output
300 W Gold
(One power supply)
100 - 127 V AC 334 W 4 A 1139 BTU/hour
200 - 240 V AC 326 W 2 A 1111 BTU/hour
450 W Platinum
(Two power supplies)
100 - 127 V AC 503 W 5.8 A 1717 BTU/hour
200 - 240 V AC 484 W 2.9 A 1650 BTU/hour

Warranty and support

The SR250 server comes with a three-year (Machine Type 7Y51) or one-year (Machine Type 7Y52) customer-replaceable unit (CRU) and onsite limited (for field-replaceable units [FRUs] only) warranty with standard call center support during normal business hours and 9x5 Next Business Day Parts Delivered.

Lenovo’s additional support services provide a sophisticated, unified support structure for a customer's data center, with an experience consistently ranked number one in customer satisfaction worldwide. The following Lenovo support services are available:

  • Premier Support provides a Lenovo-owned customer experience and delivers direct access to technicians skilled in hardware, software, and advanced troubleshooting, in addition to the following capabilities:  
    • Direct technician-to-technician access through a dedicated phone line.
    • 24x7x365 remote support.
    • Single point of contact service.
    • End to end case management.
    • 3rd Party collaborative software support. 
    • Online case tools and live chat support.
    • On-demand remote system analysis.
  • Warranty Upgrades (Preconfigured Support) are available to meet the on-site response time targets that match the criticality of customer's systems:
    • 3, 4, or 5 years of service coverage.
    • 1-year or 2-year post-warranty extensions.
    • Foundation Service: 9x5 service coverage with next business day onsite response, with optional YourDrive YourData.
    • Essential Service: 24x7 service coverage with 4-hour onsite response or 24-hour committed repair (available only in select regions), bundled with YourDrive YourData.
    • Advanced Service: 24x7 service coverage with 2-hour onsite response or 6-hour committed repair (available only in select regions), bundled with YourDrive YourData.
  • Managed Services

    Lenovo Managed Services provide continuous 24x7 remote monitoring (plus 24x7 call center availability) and proactive management of a customer's data center using state of the art tools, systems, and practices by a team of highly skilled and experienced Lenovo services professionals.

    Quarterly reviews check error logs, verify firmware and operating system device driver levels, and software as needed. Lenovo will also maintain records of latest patches, critical updates, and firmware levels, to ensure customer's systems are providing business value through optimized performance.

  • Technical Account Management (TAM)

    A Lenovo Technical Account Manager helps customers optimize operations of their data centers based on a deep understanding of customer's business. Customers gain direct access to a Lenovo TAM, who serves as their single point of contact to expedite service requests, provide status updates, and furnish reports to track incidents over time. Also, a TAM helps proactively make service recommendations and manage service relationship with Lenovo to make certain that customer's needs are met.

  • Enterprise Software Support

    Lenovo Enterprise Software Support is an additional support service that provides customers with software support on Microsoft, Red Hat, SUSE, and VMWare applications and systems. Around the clock availability for critical problems plus unlimited calls and incidents helps customers address challenges fast, without incremental costs. Support staff can answer troubleshooting and diagnostic questions, address product compatibility and interoperability issues, isolate causes of problems, report defects to software vendors, and more.

  • YourDrive YourData

    Lenovo’s YourDrive YourData service is a multi-drive retention offering that ensures that customer's data is always under their control, regardless of the number of drives that are installed in their Lenovo server. In the unlikely event of a drive failure, customers retain possession of their drive while Lenovo replaces the failed drive part. Customer's data stays safely on customer premises, in their hands. The YourDrive YourData service can be purchased in convenient bundles with Foundation, Essential, or Advanced Service upgrades and extensions.

  • Health Check

    Having a trusted partner who can perform regular and detailed health checks is central to maintaining efficiency and ensuring that customer systems and business are always running at their best. Health Check supports Lenovo-branded server, storage, and networking devices, as well as select Lenovo-supported products from other vendors that are sold by Lenovo or a Lenovo-Authorized Reseller.

Some regions might have different warranty terms and conditions than the standard warranty. This is due to local business practices or laws in the specific region. Local service teams can assist in explaining region-specific terms when needed. Examples of region-specific warranty terms are second or longer business day parts delivery or parts-only base warranty.

If warranty terms and conditions include onsite labor for repair or replacement of parts, Lenovo will dispatch a service technician to the customer site to perform the replacement. Onsite labor under base warranty is limited to labor for replacement of parts that have been determined to be field-replaceable units (FRUs). Parts that are determined to be customer-replaceable units (CRUs) do not include onsite labor under base warranty.

If warranty terms include parts-only base warranty, Lenovo is responsible for delivering only replacement parts that are under base warranty (including FRUs) that will be sent to a requested location for self-service. Parts-only service does not include a service technician being dispatched onsite. Parts must be changed at customer’s own cost and labor and defective parts must be returned following the instructions supplied with the spare parts.

Lenovo support services are region-specific. Not all support services are available in every region. For information about Lenovo support services that are available in a specific region, refer to the following resources:

For service definitions, region-specific details, and service limitations, refer to the following documents:

Services

Lenovo Services is a dedicated partner to customer success. Lenovo's goal for customers is to reduce capital outlays, mitigate IT risks, and accelerate time to productivity.

Here is a more in-depth look at what Lenovo can do for their customers:

  • Asset Recovery Services

    Asset Recovery Services (ARS) helps customers recover the maximum value from their end-of-life equipment in a cost-effective and secure way. On top of simplifying the transition from old to new equipment, ARS mitigates environmental and data security risks associated with data center equipment disposal. Lenovo ARS is a cash-back solution for equipment based on its remaining market value, yielding maximum value from aging assets and lowering total cost of ownership for customers. For more information, see the ARS page, http://lenovopress.com/lp1266.

  • Assessment Services

    An assessment helps solve customer IT challenges through an onsite, multi-day session with a Lenovo technology expert. Lenovo performs a tools-based assessment which provides a comprehensive and thorough review of a company's environment and technology systems. In addition to the technology-based functional requirements, the consultant also discusses and records the non-functional business requirements, challenges, and constraints. Assessments help organizations, no matter how large or small, get a better return on their IT investment and overcome challenges in the ever-changing technology landscape.

  • Design Services

    Professional Services consultants perform infrastructure design and implementation planning to support customer's strategy. The high-level architectures provided by the assessment service are turned into low level designs and wiring diagrams, which are reviewed and approved prior to implementation. The implementation plan will demonstrate an outcome-based proposal to provide business capabilities through infrastructure with a risk-mitigated project plan.

  • Basic Hardware Installation

    Lenovo experts can seamlessly manage the physical installation of customer's server, storage, or networking hardware. Working at a time convenient for the customer (business hours or off shift), the technician will unpack and inspect the systems on customer site, install options, mount in a rack cabinet, connect to power and network, check and update firmware to the latest levels, verify operation, and dispose of the packaging, allowing customers to focus on other priorities.

  • Deployment Services

    When investing in new IT infrastructures, customers need to ensure that their business will see quick time to value with little to no disruption. Lenovo deployments are designed by development and engineering teams who know Lenovo products and solutions better than anyone else, and Lenovo technicians own the process from delivery to completion. Lenovo will conduct remote preparation and planning, configure and integrate systems, validate systems, verify and update appliance firmware, train on administrative tasks, and provide post-deployment documentation. Customer’s IT teams leverage Lenovo skills to enable IT staff to transform with higher level roles and tasks.

  • Integration, Migration, and Expansion Services

    Integration, Migration, and Expansion Services allow to move existing physical and virtual workloads easily, or to determine technical requirements to support increased workloads while maximizing performance. These services include tuning, validation, and documenting ongoing run processes, and they leverage migration assessment planning documents to perform necessary migrations.

Some service options may not be available in every region. For more information about Lenovo service offerings that are available in a specific region, contact a local Lenovo sales representative or business partner.

Regulatory compliance

The ThinkSystem SR250 server conforms to the following regulations:

  • Energy Star 3.0
  • FCC Title 47 CFR Part 15 Subpart B
  • ICES-003/NMB-03, Class A
  • UL62368-1
  • NOM-019
  • VCCI, Class A
  • AS/NZS CISPR 32, Class A
  • CCC GB4943.1, GB9254 Class A, GB17625.1, CECP, CELP
  • BSMI CNS13438, Class A; CNS14336-1; CNS15663
  • KN32, Class A; KN35
  • BIS
  • TR CU 020/2011; TR CU 004/2011
  • IEC60950-1, IEC62368-1 (CB Certificate and CB Test Report)
  • CE Mark (EN55032 Class A, EN60950-1, EN55024, EN50581, EN61000-3-2, EN61000-3-3, EN62368-1)
  • CISPR 32, Class A
  • TUV-GS (EK1-ITB2000, EN62368-1)
  • Reduction of Hazardous Substances (ROHS)

External drive enclosures

The server supports attachment to external drive enclosures using a RAID controller with external ports or a SAS host bus adapter. Adapters supported by the server are listed in the SAS adapters for external storage section.

Note: Information provided in this section is for ordering reference purposes only. For the operating system and adapter support details, refer to the interoperability matrix for a particular storage enclosure that can be found on the Lenovo Data Center Support web site:
http://datacentersupport.lenovo.com

Table 54. External drive enclosures
Model Description
4587HC1 Lenovo Storage D1212 Disk Expansion Enclosure (2U enclosure with 12x LFF drive bays)
4587HC2 Lenovo Storage D1224 Disk Expansion Enclosure (2U enclosure with 24x SFF drive bays)
6413HC1 Lenovo Storage D3284 High Density Expansion Enclosure (5U enclosure with 84x LFF drive bays)
7DAHCTO1WW Lenovo ThinkSystem D4390 Direct Attached Storage (4U enclosure with 90x LFF drive bays)

For details about supported drives, adapters, and cables, see the following Lenovo Press Product Guides:

External storage systems

Lenovo offers the ThinkSystem DE Series and ThinkSystem DM Series external storage systems for high-performance storage. See the DE Series and DM Series product guides for specific controller models, expansion enclosures and configuration options:

External backup units

The following table lists the external backup options that are offered by Lenovo.

Table 55. External backup options
Part number Description
External RDX USB drives
4T27A10725 ThinkSystem RDX External USB 3.0 Dock
External SAS tape backup drives
6160S7E IBM TS2270 Tape Drive Model H7S
6160S8E IBM TS2280 Tape Drive Model H8S
6160S9E IBM TS2290 Tape Drive Model H9S
External SAS tape backup autoloaders
6171S7R IBM TS2900 Tape Autoloader w/LTO7 HH SAS
6171S8R IBM TS2900 Tape Autoloader w/LTO8 HH SAS
6171S9R IBM TS2900 Tape Autoloader w/LTO9 HH SAS
External tape backup libraries
6741A1F IBM TS4300 3U Tape Library-Base Unit
6741A3F IBM TS4300 3U Tape Library-Expansion Unit
Full High 8 Gb Fibre Channel for TS4300
01KP938 LTO 7 FH Fibre Channel Drive
01KP954 LTO 8 FH Fibre Channel Drive
02JH837 LTO 9 FH Fibre Channel Drive
Half High 8 Gb Fibre Channel for TS4300
01KP936 LTO 7 HH Fibre Channel Drive
01KP952 LTO 8 HH Fibre Channel Drive
02JH835 LTO 9 HH Fibre Channel Drive
Half High 6 Gb SAS for TS4300
01KP937 LTO 7 HH SAS Drive
01KP953 LTO 8 HH SAS Drive
02JH836 LTO 9 HH SAS Drive

For more information, see the list of Product Guides in the Backup units category:
https://lenovopress.com/servers/options/backup

Ethernet LAN switches

The following table lists the Ethernet LAN switches that are offered by Lenovo.

Table 56. Ethernet LAN switches
Part number Description
1 Gb Ethernet Rack switches
7Y810011WW Lenovo ThinkSystem NE0152T RackSwitch (Rear to Front)
7Z320O11WW Lenovo ThinkSystem NE0152TO RackSwitch (Rear to Front, ONIE)
7159BAX Lenovo RackSwitch G7028 (Rear to Front)
7159CAX Lenovo RackSwitch G7052 (Rear to Front)
7159G52 Lenovo RackSwitch G8052 (Rear to Front)
7165H1X Juniper EX2300-C PoE Switch
7165H2X Juniper EX2300-24p PoE Switch
1 Gb Ethernet Campus switches
7Z340011WW Lenovo CE0128TB Switch (3-Year Warranty)
7Z360011WW Lenovo CE0128TB Switch (Limited Lifetime Warranty)
7Z340012WW Lenovo CE0128PB Switch (3-Year Warranty)
7Z360012WW Lenovo CE0128PB Switch (Limited Lifetime Warranty)
7Z350021WW Lenovo CE0152TB Switch (3-Year Warranty)
7Z370021WW Lenovo CE0152TB Switch (Limited Lifetime Warranty)
7Z350022WW Lenovo CE0152PB Switch (3-Year Warranty)
7Z370022WW Lenovo CE0152PB Switch (Limited Lifetime Warranty)
10 Gb Ethernet switches
7159A1X Lenovo ThinkSystem NE1032 RackSwitch (Rear to Front)
7159B1X Lenovo ThinkSystem NE1032T RackSwitch (Rear to Front)
7Z330O11WW Lenovo ThinkSystem NE1064TO RackSwitch (Rear to Front, ONIE)
7159C1X Lenovo ThinkSystem NE1072T RackSwitch (Rear to Front)
7159CRW Lenovo RackSwitch G8272 (Rear to Front)
7159GR6 Lenovo RackSwitch G8296 (Rear to Front)
7159BR6 Lenovo RackSwitch G8124E (Rear to Front)
25 Gb Ethernet switches
7159E1X Lenovo ThinkSystem NE2572 RackSwitch (Rear to Front)
7Z210O21WW Lenovo ThinkSystem NE2572O RackSwitch (Rear to Front, ONIE)
7Z330O21WW Lenovo ThinkSystem NE2580O RackSwitch (Rear to Front, ONIE)
100 Gb Ethernet switches
7159D1X Lenovo ThinkSystem NE10032 RackSwitch (Rear to Front)
7Z210O11WW Lenovo ThinkSystem NE10032O RackSwitch (Rear to Front, ONIE)

For more information, see the list of Product Guides in the following switch categories:

Fibre Channel SAN switches

Lenovo offers the ThinkSystem DB Series of Fibre Channel SAN switches for high-performance storage expansion. See the DB Series product guides for models and configuration options:

Rack cabinets

The following table lists the supported rack cabinets.

Table 57. Rack cabinets
ModelDescription
93072RX25U Standard Rack (1000mm)
93072PX25U Static S2 Standard Rack (1000mm)
7D6DA007WWThinkSystem 42U Onyx Primary Heavy Duty Rack Cabinet (1200mm)
7D6DA008WWThinkSystem 42U Pearl Primary Heavy Duty Rack Cabinet (1200mm)
7D6EA009WWThinkSystem 48U Onyx Primary Heavy Duty Rack Cabinet (1200mm)
7D6EA00AWWThinkSystem 48U Pearl Primary Heavy Duty Rack Cabinet (1200mm)
1410O42Lenovo EveryScale 42U Onyx Heavy Duty Rack Cabinet
1410P42Lenovo EveryScale 42U Pearl Heavy Duty Rack Cabinet
1410O48Lenovo EveryScale 48U Onyx Heavy Duty Rack Cabinet
1410P48Lenovo EveryScale 48U Pearl Heavy Duty Rack Cabinet
93604PX42U 1200mm Deep Dynamic Rack
93614PX42U 1200mm Deep Static Rack
93634PX42U 1100mm Dynamic Rack
93634EX42U 1100mm Dynamic Expansion Rack
93074RX42U Standard Rack (1000mm)
93084PX42U Enterprise Rack
93084EX42U Enterprise Expansion Rack

For specifications about these racks, see the Lenovo Rack Cabinet Reference, available from:
https://lenovopress.com/lp1287-lenovo-rack-cabinet-reference

For more information, see the list of Product Guides in the Rack cabinets category:
https://lenovopress.com/servers/options/racks

KVM switches and consoles

The following table lists the supported KVM consoles.

Table 58. KVM console
Part number Description
Consoles
4XF7A84188 ThinkSystem 18.5" LCD Console (with US English keyboard)
4XF7A73009 ThinkSystem 18.5" LCD console (with US English keyboard)
17238BX 1U 18.5" Standard Console (without keyboard - see the next table)

The following table lists the keyboards supported with the 1U 18.5" Standard Console (now withdrawn).

Note: These keyboards are not supported with the ThinkSystem 18.5" LCD Console.

Table 59. Keyboards for 1U 18.5" Standard Console
Part number Description
7ZB7A05469 ThinkSystem Keyboard w/ Int.Pointing Device USB - Arabic 253 RoHS v2
7ZB7A05468 ThinkSystem Keyboard w/ Int. Pointing Device USB - Belg/UK 120 RoHS v2
7ZB7A05206 ThinkSystem Keyboard w/ Int. Pointing Device USB - Czech 489 RoHS v2
7ZB7A05207 ThinkSystem Keyboard w/ Int. Pointing Device USB - Danish 159 RoHS v2
7ZB7A05208 ThinkSystem Keyboard w/ Int. Pointing Device USB - Dutch 143 RoHS v2
7ZB7A05210 ThinkSystem Keyboard w/ Int. Pointing Device USB - Fr/Canada 445 RoHS v2
7ZB7A05209 ThinkSystem Keyboard w/ Int. Pointing Device USB - French 189 RoHS v2
7ZB7A05211 ThinkSystem Keyboard w/ Int. Pointing Device USB - German 129 RoHS v2
7ZB7A05212 ThinkSystem Keyboard w/ Int. Pointing Device USB - Greek 219 RoHS v2
7ZB7A05213 ThinkSystem Keyboard w/ Int. Pointing Device USB - Hebrew 212 RoHS v2
7ZB7A05214 ThinkSystem Keyboard w/ Int. Pointing Device USB - Hungarian 208 RoHS v2
7ZB7A05215 ThinkSystem Keyboard w/ Int. Pointing Device USB - Italian 141 RoHS v2
7ZB7A05216 ThinkSystem Keyboard w/ Int. Pointing Device USB - Japanese 194 RoHS v2
7ZB7A05217 ThinkSystem Keyboard w/ Int. Pointing Device USB - Korean 413 RoHS v2
7ZB7A05218 ThinkSystem Keyboard w/ Int. Pointing Device USB - LA Span 171 RoHS v2
7ZB7A05219 ThinkSystem Keyboard w/ Int. Pointing Device USB - Norwegian 155 RoHS v2
7ZB7A05220 ThinkSystem Keyboard w/ Int. Pointing Device USB - Polish 214 RoHS v2
7ZB7A05221 ThinkSystem Keyboard w/ Int. Pointing Device USB - Portugese 163 RoHS v2
7ZB7A05222 ThinkSystem Keyboard w/ Int. Pointing Device USB - Russian 441 RoHS v2
7ZB7A05223 ThinkSystem Keyboard w/ Int. Pointing Device USB - Slovak 245 RoHS v2
7ZB7A05231 ThinkSystem Keyboard w/ Int. Pointing Device USB - Slovenian 234 RoHS v2
7ZB7A05224 ThinkSystem Keyboard w/ Int. Pointing Device USB - Spanish 172 RoHS v2
7ZB7A05225 ThinkSystem Keyboard w/ Int. Pointing Device USB - Swed/Finn 153 RoHS v2
7ZB7A05226 ThinkSystem Keyboard w/ Int. Pointing Device USB - Swiss F/G 150 RoHS v2
7ZB7A05227 ThinkSystem Keyboard w/ Int. Pointing Device USB - Thai 191 RoHS v2
7ZB7A05467 ThinkSystem Keyboard with Int. Pointing Device USB - Trad Chinese/US 467 RoHS v2
7ZB7A05228 ThinkSystem Keyboard w/ Int. Pointing Device USB - Turkish 179 RoHS v2
7ZB7A05229 ThinkSystem Keyboard w/ Int. Pointing Device USB - UK Eng 166 RoHS v2
7ZB7A05470 ThinkSystem Keyboard w/ Int. Pointing Device USB - US Eng 103P RoHS v2
7ZB7A05230 ThinkSystem Keyboard w/ Int. Pointing Device USB - US Euro 103P RoHS v2

The following table lists the available KVM switches and the options that are supported with them.

Table 60. KVM switches and options
Part number Description
KVM Console switches
1754D1T ThinkSystem Digital 2x1x16 KVM Switch (DVI video output port)
1754A1T ThinkSystem Analog 1x8 KVM Switch (DVI video output port)
1754D2X Global 4x2x32 Console Manager (GCM32)
1754D1X Global 2x2x16 Console Manager (GCM16)
1754A2X Local 2x16 Console Manager (LCM16)
1754A1X Local 1x8 Console Manager (LCM8)
Cables for ThinkSystem Digital and Analog KVM Console switches
4X97A11108 ThinkSystem VGA to DVI Conversion Cable
4X97A11109 ThinkSystem Single-USB Conversion Cable for Digital KVM
4X97A11107 ThinkSystem Dual-USB Conversion Cable for Digital KVM
4X97A11106 ThinkSystem USB Conversion Cable for Analog KVM
Cables for GCM and LCM Console switches
43V6147 Single Cable USB Conversion Option (UCO)
39M2895 USB Conversion Option Pack
46M5383 Virtual Media Conversion Option Gen2 (VCO2)
46M5382 Serial Conversion Option (SCO)

For more information, see the list of Product Guides in the KVM Switches and Consoles category:
http://lenovopress.com/servers/options/kvm

Power distribution units

The following table lists the power distribution units (PDUs) that are offered by Lenovo.

Table 61. Power distribution units
Part
number
Feature
code
Description
ANZ
ASEAN
Brazil
EET
MEA
RUCIS
WE
HTK
INDIA
JAPAN
LA
NA
PRC
0U Basic PDUs
4PU7A93176 C0QH 0U 36 C13 and 6 C19 Basic 32A 1 Phase PDU v2 Y Y Y Y Y Y Y Y Y N Y Y Y
4PU7A93169 C0DA 0U 36 C13 and 6 C19 Basic 32A 1 Phase PDU Y Y Y Y Y Y Y Y Y N Y Y Y
4PU7A93177 C0QJ 0U 24 C13/C15 and 24 C13/C15/C19 Basic 32A 3 Phase WYE PDU v2 Y Y Y Y Y Y Y Y Y Y Y Y Y
4PU7A93170 C0D9 0U 24 C13/C15 and 24 C13/C15/C19 Basic 32A 3 Phase WYE PDU Y Y Y Y Y Y Y Y Y N Y Y Y
00YJ776 ATZY 0U 36 C13/6 C19 24A 1 Phase PDU N Y Y N N N N N N Y Y Y N
00YJ779 ATZX 0U 21 C13/12 C19 48A 3 Phase PDU N N Y N N N Y N N Y Y Y N
00YJ777 ATZZ 0U 36 C13/6 C19 32A 1 Phase PDU Y Y N Y Y Y Y Y Y N N Y Y
00YJ778 AU00 0U 21 C13/12 C19 32A 3 Phase PDU Y Y N Y Y Y Y Y Y N N Y Y
0U Switched and Monitored PDUs
4PU7A93181 C0QN 0U 21 C13/C15 and 21 C13/C15/C19 Switched and Monitored 48A 3 Phase Delta PDU v2 (60A derated) N Y N N N N N Y N Y N Y N
4PU7A93174 C0D5 0U 21 C13/C15 and 21 C13/C15/C19 Switched and Monitored 48A 3 Phase Delta PDU (60A derated) N Y N Y N N Y Y N N N Y N
4PU7A93178 C0QK 0U 20 C13 and 4 C19 Switched and Monitored 32A 1 Phase PDU v2 Y Y Y Y Y Y Y Y Y N Y Y Y
4PU7A93171 C0D8 0U 20 C13 and 4 C19 Switched and Monitored 32A 1 Phase PDU Y Y Y Y Y Y Y Y Y N Y Y Y
4PU7A93182 C0QP 0U 18 C13/C15 and 18 C13/C15/C19 Switched and Monitored 63A 3 Phase WYE PDU v2 Y Y Y Y Y Y Y Y Y Y Y Y Y
4PU7A93175 C0CS 0U 18 C13/C15 and 18 C13/C15/C19 Switched and Monitored 63A 3 Phase WYE PDU Y Y Y Y Y Y Y Y Y N Y Y Y
4PU7A93180 C0QM 0U 18 C13/C15 and 18 C13/C15/C19 Switched and Monitored 32A 3 Phase WYE PDU v2 Y Y Y Y Y Y Y Y Y Y Y Y Y
4PU7A93173 C0D6 0U 18 C13/C15 and 18 C13/C15/C19 Switched and Monitored 32A 3 Phase WYE PDU Y Y Y Y Y Y Y Y Y N Y Y Y
4PU7A93179 C0QL 0U 16 C13/C15 and 16 C13/C15/C19 Switched and Monitored 24A 1 Phase PDU v2 (30A derated) N Y N N N N N Y N Y N Y N
4PU7A93172 C0D7 0U 16 C13/C15 and 16 C13/C15/C19 Switched and Monitored 24A 1 Phase PDU(30A derated) N Y N Y N N Y Y N N N Y N
00YJ783 AU04 0U 12 C13/12 C19 Switched and Monitored 48A 3 Phase PDU N N Y N N N Y N N Y Y Y N
00YJ781 AU03 0U 20 C13/4 C19 Switched and Monitored 24A 1 Phase PDU N N Y N Y N Y N N Y Y Y N
00YJ782 AU02 0U 18 C13/6 C19 Switched and Monitored 32A 3 Phase PDU Y Y Y Y Y Y Y Y Y N Y N Y
00YJ780 AU01 0U 20 C13/4 C19 Switched and Monitored 32A 1 Phase PDU Y Y Y Y Y Y Y Y Y N Y N Y
1U Switched and Monitored PDUs
4PU7A90808 C0D4 1U 18 C19/C13 Switched and monitored 48A 3P WYE PDU V2 ETL Y Y Y Y Y Y Y Y Y Y Y Y Y
4PU7A81117 BNDV 1U 18 C19/C13 switched and monitored 48A 3P WYE PDU - ETL N N N N N N N N N N N Y N
4PU7A90809 C0DE 1U 18 C19/C13 Switched and monitored 48A 3P WYE PDU V2 CE N N N N N Y Y N N N N N N
4PU7A81118 BNDW 1U 18 C19/C13 switched and monitored 48A 3P WYE PDU - CE Y Y Y Y Y Y Y Y Y N Y N Y
4PU7A90810 C0DD 1U 18 C19/C13 Switched and monitored 80A 3P Delta PDU V2 Y Y Y Y Y Y Y Y Y Y Y Y Y
4PU7A77467 BLC4 1U 18 C19/C13 Switched and Monitored 80A 3P Delta PDU N N N N N N N N N Y N Y N
4PU7A90811 C0DC 1U 12 C19/C13 Switched and monitored 32A 3P WYE PDU V2 N N N N N Y Y N N N N N N
4PU7A77468 BLC5 1U 12 C19/C13 switched and monitored 32A 3P WYE PDU Y Y Y Y Y Y Y Y Y Y Y Y Y
4PU7A90812 C0DB 1U 12 C19/C13 Switched and monitored 60A 3P Delta PDU V2 N N N N N N N N N Y N N N
4PU7A77469 BLC6 1U 12 C19/C13 switched and monitored 60A 3P Delta PDU N N N N N N N N N N N Y N
46M4002 5896 1U 9 C19/3 C13 Switched and Monitored DPI PDU Y Y Y Y Y Y Y Y Y Y Y Y Y
46M4004 5894 1U 12 C13 Switched and Monitored DPI PDU Y Y Y Y Y Y Y Y Y Y Y Y Y
46M4003 5897 1U 9 C19/3 C13 Switched and Monitored 60A 3 Phase PDU Y Y Y Y Y Y Y Y Y Y Y Y Y
46M4005 5895 1U 12 C13 Switched and Monitored 60A 3 Phase PDU Y Y Y Y Y Y Y Y Y Y Y Y Y
1U Ultra Density Enterprise PDUs (9x IEC 320 C13 + 3x IEC 320 C19 outlets)
71763NU 6051 Ultra Density Enterprise C19/C13 PDU 60A/208V/3PH N N Y N N N N N N Y Y Y N
71762NX 6091 Ultra Density Enterprise C19/C13 PDU Module Y Y Y Y Y Y Y Y Y Y Y Y Y
1U C13 Enterprise PDUs (12x IEC 320 C13 outlets)
39M2816 6030 DPI C13 Enterprise PDU Plus Module (WW) Y Y Y Y Y Y Y Y Y Y Y Y Y
39Y8941 6010 DPI C13 Enterprise PDU Module (WW) Y Y Y Y Y Y Y Y Y Y Y Y Y
1U C19 Enterprise PDUs (6x IEC 320 C19 outlets)
39Y8948 6060 DPI C19 Enterprise PDU Module (WW) Y Y Y Y Y Y Y Y Y Y Y Y Y
39Y8923 6061 DPI Three-phase 60A/208V C19 Enterprise PDU (US) N N Y N N N Y N N N Y Y N
1U Front-end PDUs (3x IEC 320 C19 outlets)
39Y8938 6002 DPI Single-phase 30A/120V Front-end PDU (US) Y Y Y Y Y Y Y Y Y Y Y Y Y
39Y8939 6003 DPI Single-phase 30A/208V Front-end PDU (US) Y Y Y Y Y Y Y Y Y Y Y Y Y
39Y8934 6005 DPI Single-phase 32A/230V Front-end PDU (International) Y Y Y Y Y Y Y Y Y Y Y Y Y
39Y8940 6004 DPI Single-phase 60A/208V Front-end PDU (US) Y N Y Y Y Y Y N N Y Y Y N
39Y8935 6006 DPI Single-phase 63A/230V Front-end PDU (International) Y Y Y Y Y Y Y Y Y Y Y Y Y
1U NEMA PDUs (6x NEMA 5-15R outlets)
39Y8905 5900 DPI 100-127V NEMA PDU Y Y Y Y Y Y Y Y Y Y Y Y Y
Line cords for 1U PDUs that ship without a line cord
40K9611 6504 4.3m, 32A/380-415V, EPDU/IEC 309 3P+N+G 3ph wye (non-US) Line Cord Y Y Y Y Y Y Y Y Y Y Y Y Y
40K9612 6502 4.3m, 32A/230V, EPDU to IEC 309 P+N+G (non-US) Line Cord Y Y Y Y Y Y Y Y Y Y Y Y Y
40K9613 6503 4.3m, 63A/230V, EPDU to IEC 309 P+N+G (non-US) Line Cord Y Y Y Y Y Y Y Y Y Y Y Y Y
40K9614 6500 4.3m, 30A/208V, EPDU to NEMA L6-30P (US) Line Cord Y Y Y Y Y Y Y Y Y Y Y Y Y
40K9615 6501 4.3m, 60A/208V, EPDU to IEC 309 2P+G (US) Line Cord N N Y N N N Y N N Y Y Y N
40K9617 6505 4.3m, 32A/230V, Souriau UTG Female to AS/NZ 3112 (Aus/NZ) Line Cord Y Y Y Y Y Y Y Y Y Y Y Y Y
40K9618 6506 4.3m, 32A/250V, Souriau UTG Female to KSC 8305 (S. Korea) Line Cord Y Y Y Y Y Y Y Y Y Y Y Y Y

For more information, see the Lenovo Press documents in the PDU category:
https://lenovopress.com/servers/options/pdu

Uninterruptible power supply units

The following table lists the uninterruptible power supply (UPS) units that are offered by Lenovo.

Table 62. Uninterruptible power supply units
Part number Description
Rack-mounted or tower UPS units - 100-125VAC
7DD5A001WW RT1.5kVA 2U Rack or Tower UPS-G2 (100-125VAC)
55941AX RT1.5kVA 2U Rack or Tower UPS (100-125VAC)
55942AX RT2.2kVA 2U Rack or Tower UPS (100-125VAC)
7DD5A003WW RT3kVA 2U Rack or Tower UPS-G2 (100-125VAC)
55943AX RT3kVA 2U Rack or Tower UPS (100-125VAC)
Rack-mounted or tower UPS units - 200-240VAC
7DD5A002WW RT1.5kVA 2U Rack or Tower UPS-G2 (200-240VAC)
55941KX RT1.5kVA 2U Rack or Tower UPS (200-240VAC)
55942KX RT2.2kVA 2U Rack or Tower UPS (200-240VAC)
7DD5A005WW RT3kVA 2U Rack or Tower UPS-G2 (200-240VAC)
55943KX RT3kVA 2U Rack or Tower UPS (200-240VAC)
7DD5A007WW RT5kVA 3U Rack or Tower UPS-G2 (200-240VAC)
55945KX RT5kVA 3U Rack or Tower UPS (200-240VAC)
7DD5A008WW RT6kVA 3U Rack or Tower UPS-G2 (200-240VAC)
55946KX RT6kVA 3U Rack or Tower UPS (200-240VAC)
55948KX RT8kVA 6U Rack or Tower UPS (200-240VAC)
7DD5A00AWW RT11kVA 6U Rack or Tower UPS-G2 (200-240VAC)
55949KX RT11kVA 6U Rack or Tower UPS (200-240VAC)
55943KT† ThinkSystem RT3kVA 2U Standard UPS (200-230VAC) (2x C13 10A, 2x GB 10A, 1x C19 16A outlets)
55943LT† ThinkSystem RT3kVA 2U Long Backup UPS (200-230VAC) (2x C13 10A, 2x GB 10A, 1x C19 16A outlets)
55946KT† ThinkSystem RT6kVA 5U UPS (200-230VAC) (2x C13 10A outlets, 1x Terminal Block output)
5594XKT† ThinkSystem RT10kVA 5U UPS (200-230VAC) (2x C13 10A outlets, 1x Terminal Block output)
Rack-mounted or tower UPS units - 380-415VAC
55948PX RT8kVA 6U 3:1 Phase Rack or Tower UPS (380-415VAC)
55949PX RT11kVA 6U 3:1 Phase Rack or Tower UPS (380-415VAC)

† Only available in China and the Asia Pacific market.

For more information, see the list of Product Guides in the UPS category:
https://lenovopress.com/servers/options/ups

Lenovo Financial Services

Why wait to obtain the technology you need now? No payments for 90 days and predictable, low monthly payments make it easy to budget for your Lenovo solution.

  • Flexible

    Our in-depth knowledge of the products, services and various market segments allows us to offer greater flexibility in structures, documentation and end of lease options.

  • 100% Solution Financing

    Financing your entire solution including hardware, software, and services, ensures more predictability in your project planning with fixed, manageable payments and low monthly payments.

  • Device as a Service (DaaS)

    Leverage latest technology to advance your business. Customized solutions aligned to your needs. Flexibility to add equipment to support growth. Protect your technology with Lenovo's Premier Support service.

  • 24/7 Asset management

    Manage your financed solutions with electronic access to your lease documents, payment histories, invoices and asset information.

  • Fair Market Value (FMV) and $1 Purchase Option Leases

    Maximize your purchasing power with our lowest cost option. An FMV lease offers lower monthly payments than loans or lease-to-own financing. Think of an FMV lease as a rental. You have the flexibility at the end of the lease term to return the equipment, continue leasing it, or purchase it for the fair market value. In a $1 Out Purchase Option lease, you own the equipment. It is a good option when you are confident you will use the equipment for an extended period beyond the finance term. Both lease types have merits depending on your needs. We can help you determine which option will best meet your technological and budgetary goals.

Ask your Lenovo Financial Services representative about this promotion and how to submit a credit application. For the majority of credit applicants, we have enough information to deliver an instant decision and send a notification within minutes.

Related product families

Product families related to this document are the following:

Trademarks

Lenovo and the Lenovo logo are trademarks or registered trademarks of Lenovo in the United States, other countries, or both. A current list of Lenovo trademarks is available on the Web at https://www.lenovo.com/us/en/legal/copytrade/.

The following terms are trademarks of Lenovo in the United States, other countries, or both:
Lenovo®
AnyBay®
System x®
ThinkServer®
ThinkSystem®
XClarity®

The following terms are trademarks of other companies:

AMD is a trademark of Advanced Micro Devices, Inc.

Intel®, Celeron®, Intel Core®, Pentium®, and Xeon® are trademarks of Intel Corporation or its subsidiaries.

Linux® is the trademark of Linus Torvalds in the U.S. and other countries.

Microsoft®, Hyper-V®, PowerShell, Windows PowerShell®, Windows Server®, and Windows® are trademarks of Microsoft Corporation in the United States, other countries, or both.

SPECpower® is a trademark of the Standard Performance Evaluation Corporation (SPEC).

Other company, product, or service names may be trademarks or service marks of others.