Abstract
The Flex System™ FC3172 2-port 8Gb FC Adapter enables high-speed access for Flex System compute nodes to connect to a Fibre Channel storage area network (SAN). This adapter is based on the proven QLogic 2532 8Gb ASIC design and works with the 8 Gb and 16 Gb Flex System Fibre Channel switches and pass-thru modules.
Introduction
The Flex System™ FC3172 2-port 8Gb FC Adapter enables high-speed access for Flex System compute nodes to connect to a Fibre Channel storage area network (SAN). This adapter is based on the proven QLogic 2532 8Gb ASIC design and works with the 8 Gb and 16 Gb Flex System Fibre Channel switches and pass-thru modules.
Figure 1 shows the Flex System FC3172 2-port 8Gb FC Adapter.
Figure 1. Flex System FC3172 2-port 8Gb FC Adapter
Did you know?
The performance bottleneck with Fibre Channel storage typically exists in the switching. By moving to 8 Gb adapters and switches, you can optimize the bottleneck to the storage controller, where it can be managed by expanding the disks attached to storage. When compared to the previous-generation 4 Gb adapters, the new-generation 8 Gb adapters double the throughput speeds for Fibre Channel traffic. As a result, you can manage increased amounts of data and possibly benefit from a reduced hardware expense.
The adapter connects to the midplane directly, without having to use cables or small form-factor pluggable (SFP) modules. By eliminating these components for up to 14 servers, the resulting savings alone can cover the investment in the chassis.
Part number information
Table 1 shows the part number to order this card.
Table 1. Part number and feature code for ordering
Description | Part number | Feature code (x86 servers) |
Feature ocde (Power Systems) |
Flex System FC3172 2-port 8Gb FC Adapter | 69Y1938 | A1BM | 1764 |
The part number includes the following items:
- One Flex System FC3172 2-port 8Gb FC Adapter
- Documentation package
Features
The Flex System FC3172 2-port 8Gb FC Adapter has the following features and specifications:
- QLogic ISP2532 controller
- PCI Express 2.0 x4 host interface
- Bandwidth: 8 Gb per second maximum at half-duplex and 16 Gb per second maximum at full-duplex per port
- 8/4/2 Gbps auto-negotiation
- Support for FCP SCSI initiator and target operation
- Support for NPIV
- Support for full-duplex operation
- Support for Fibre Channel protocol SCSI (FCP-SCSI) and Fibre Channel Internet protocol (FCP-IP)
- Support for point-to-point fabric connection (F-port fabric login)
- Support for Fibre Channel Arbitrated Loop (FCAL) public loop profile: Fibre Loop-(FL-Port)-Port Login
- Support for Fibre Channel services class 2 and 3
- Configuration and boot support in UEFI
- APIs supported: SNIA HBA API V2, SMI-S, FDMI
- Support for Fabric Manager
- Power usage: 3.7 W typical
- RoHS 6 compliant
Server support
The following table lists the Flex System compute nodes that support the FC3172 2-port 8Gb FC Adapter.
Table 2. Supported servers
Description | Part number |
||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flex System FC3172 2-port 8Gb FC Adapter | 69Y1938 | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
See ServerProven at the following web address for the latest information about the expansion cards that are supported by each blade server type:
http://www.lenovo.com/us/en/serverproven/flexsystem.shtml
I/O adapter cards are installed in the slot in supported servers, such as the x240, as highlighted in the following figure.
Figure 2. Location of the I/O adapter slots in the Flex System x240 Compute Node
I/O module support
The FC3172 2-port 8Gb FC Adapter supports the I/O module listed in the following table. One or two compatible switches must be installed in the corresponding I/O bays in the chassis. Installing two switches means that both ports of the adapter are enabled. When the adapter paired with a 16Gb switch, those switch ports will operate at 8 Gbps.
Table 3. I/O modules supported with the FC3172 2-port 8Gb FC Adapter
Description | Part number | Support the FC3172 adapter |
Flex System FC3171 8Gb SAN Switch | 69Y1930 | Yes |
Flex System FC3171 8Gb SAN Pass-thru | 69Y1934 | Yes |
Flex System FC5022 16Gb SAN Scalable Switch | 88Y6374 | Yes |
Flex System FC5022 24-port 16Gb SAN Scalable Switch | 00Y3324 | Yes |
Flex System FC5022 24-port 16Gb ESB SAN Scalable Switch | 90Y9356 | Yes |
The following table shows the connections between adapters installed in the compute nodes to the switch bays in the chassis.
Table 4. Adapter to I/O bay correspondence
I/O adapter slot in the server | Port on the adapter | Corresponding I/O module bay in the chassis |
Slot 1 | Port 1 | Module bay 1 |
Port 2 | Module bay 2 | |
Slot 2 | Port 1 | Module bay 3 |
Port 2 | Module bay 4 | |
Slot 3 (full-wide compute nodes only) |
Port 1 | Module bay 1 |
Port 2 | Module bay 2 | |
Slot 4 (full-wide compute nodes only) |
Port 1 | Module bay 3 |
Port 2 | Module bay 4 |
The connections between the adapters installed in the compute nodes to the switch bays in the chassis is shown diagrammatically in the following figure.
Figure 3. Logical layout of the interconnects between I/O adapters and I/O modules
Operating system support
Operating systems | p24L (1457) |
x220 (7906) |
x222 (7916) |
x240 (8737, E5 v2) |
x240 (7162) |
x240 (8737, E5 v1) |
x240 M5 (9532) |
x280/x480/x880 X6 (7196) |
x280/x480/x880 X6 (7903) |
x440 (7167) |
x440 (7917) |
---|---|---|---|---|---|---|---|---|---|---|---|
AIX Version 6.1 | Y | N | N | N | N | N | N | N | N | N | N |
AIX Version 7.1 | Y | N | N | N | N | N | N | N | N | N | N |
IBM Virtual I/O Server | Y 1 | N | N | N | N | N | N | N | N | N | N |
IBM i 6.1 | Y | N | N | N | N | N | N | N | N | N | N |
IBM i 7.1 | Y | N | N | N | N | N | N | N | N | N | N |
Microsoft Windows Server 2008 R2 | N | Y | Y | Y | N | Y | N | N | Y | Y | Y |
Microsoft Windows Server 2008, Datacenter x64 Edition | N | Y | N | Y | N | Y | N | N | N | Y | Y |
Microsoft Windows Server 2008, Enterprise x64 Edition | N | Y | N | Y | N | Y | N | N | N | Y | Y |
Microsoft Windows Server 2008, Standard x64 Edition | N | Y | N | Y | N | Y | N | N | N | Y | Y |
Microsoft Windows Server 2008, Web x64 Edition | N | Y | N | Y | N | Y | N | N | N | Y | Y |
Microsoft Windows Server 2012 | N | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Microsoft Windows Server 2012 R2 | N | Y | N | Y | Y | Y | Y | Y | Y | Y | Y |
Microsoft Windows Server version 1709 | N | N | N | N | N | N | Y | Y | N | Y | N |
Red Hat Enterprise Linux 5 Server with Xen x64 Edition | N | Y | N | Y | N | Y | N | N | N | N | Y |
Red Hat Enterprise Linux 5 Server x64 Edition | N | Y | Y | Y | N | Y | N | N | Y | N | Y |
Red Hat Enterprise Linux 5 for IBM POWER | Y | N | N | N | N | N | N | N | N | N | N |
Red Hat Enterprise Linux 6 Server Edition | N | N | N | N | Y | N | Y | Y | N | Y | N |
Red Hat Enterprise Linux 6 for IBM POWER | Y 2, 3 | N | N | N | N | N | N | N | N | N | N |
SUSE Linux Enterprise Server 10 for AMD64/EM64T | N | Y 5 | N | N | N | Y 5 | N | N | N | N | Y |
SUSE Linux Enterprise Server 11 for IBM POWER | Y 4 | N | N | N | N | N | N | N | N | N | N |
SUSE Linux Enterprise Server 11 for x86 | N | N | N | N | Y | N | Y | N | N | N | N |
VMware ESX 4.1 | N | Y | Y | N | N | Y | N | N | Y | N | Y |
VMware ESXi 4.1 | N | Y | N | N | N | Y | N | N | N | N | Y |
VMware vSphere 5.0 (ESXi) | N | Y | Y | Y | N | Y | N | N | Y | N | Y |
VMware vSphere 5.1 (ESXi) | N | Y | Y | Y | N | Y | Y | N | Y | Y | Y |
VMware vSphere Hypervisor (ESXi) 5.5 | N | Y | N | Y | Y | Y | Y | Y | Y | Y | Y |
1 Please refer to Retain Tip 26177 for additional support information.
2 Possible intermittent path failures which are recoverable in a multi-path configuration. Please refer to Red Hat Bugzilla 804613 for more information.
3 Possible intermittent path failures which are recoverable in a multi-path configuration. Please refer to Red Hat Bugzilla 804613.
4 Possible intermittent path failures which are recoverable in a multi-path configuration. Please see Novell Bugzilla 752836 for more information.
5 Use multipath-tools 7794 (https://download.novell.com/Download?buildid=EMT-YbbMvAU~)
Regulatory compliance
The adapter conforms to the following standards:
- United States FCC 47 CFR Part 15, Subpart B, ANSI C63.4 (2003), Class A
- United States UL 60950-1, Second Edition
- IEC/EN 60950-1, Second Edition
- FCC - Verified to comply with Part 15 of the FCC Rules, Class A
- Canada ICES-003, issue 4, Class A
- UL/IEC 60950-1
- CSA C22.2 No. 60950-1-03
- Japan VCCI, Class A
- Australia/New Zealand AS/NZS CISPR 22:2006, Class A
- IEC 60950-1(CB Certificate and CB Test Report)
- Taiwan BSMI CNS13438, Class A
- Korea KN22, Class A; KN24
- Russia/GOST ME01, IEC-60950-1, GOST R 51318.22-99, GOST R 51318.24-99, GOST R 51317.3.2-2006, GOST R 51317.3.3-99
- IEC 60950-1 (CB Certificate and CB Test Report)
- CE Mark (EN55022 Class A, EN60950-1, EN55024, EN61000-3-2, EN61000-3-3)
- CISPR 22, Class A
Physical specifications
The dimensions and weight of the adapter are as follows:
- Width: 100 mm (3.9 inches)
- Depth: 80 mm (3.1 inches)
- Weight: 13 g (0.3 lb)
Shipping dimensions and weight (approximate):
- Height: 58 mm (2.3 in)
- Width: 229 mm (9.0 in)
- Depth: 208 mm (8.2 in)
- Weight: 0.4 kg (0.89 lb)
Related product families
Product families related to this document are the following:
Trademarks
Lenovo and the Lenovo logo are trademarks or registered trademarks of Lenovo in the United States, other countries, or both. A current list of Lenovo trademarks is available on the Web at https://www.lenovo.com/us/en/legal/copytrade/.
The following terms are trademarks of Lenovo in the United States, other countries, or both:
Lenovo®
ServerProven®
System x®
The following terms are trademarks of other companies:
Linux® is the trademark of Linus Torvalds in the U.S. and other countries.