Abstract
Lenovo BladeCenter® remains an innovative solution to running business solutions. BladeCenter E efficiently integrates servers, storage, networking, I/O, and applications, enabling organizations to build flexible IT infrastructures by using common building blocks. In 7U of rack space, the BladeCenter E chassis can contain up to 14 blade servers, four switch modules, and four power supplies to provide the necessary I/O network switching, power, and cooling to support the individual servers.
Note: This product is withdrawn from marketing.
Change History
Changes in the December 6 update:
- Added power module FRU rating clarification
Introduction
Lenovo BladeCenter® remains an innovative solution to running business solutions. BladeCenter E efficiently integrates servers, storage, networking, I/O, and applications, enabling organizations to build flexible IT infrastructures by using common building blocks. In 7U of rack space, the BladeCenter E chassis can contain up to 14 blade servers, four switch modules, and four power supplies to provide the necessary I/O network switching, power, and cooling to support the individual servers.
Figure 1 shows the BladeCenter E.
Figure 1. The BladeCenter E
Did you know?
BladeCenter E delivers extreme density, energy efficiency, and reliability for space- and power-constrained enterprise IT environments.
The chassis supports up to four traditional fabrics by using networking switches, storage switches, or pass-through devices. The chassis offers light path diagnostics, one front USB input, and an optical drive.
Key features
This section lists the key features of the BladeCenter E chassis.
Scalability and performance
The BladeCenter E chassis offers numerous features to boost performance and improve scalability:
- Up to 14 servers with support for the latest generation of BladeCenter blades, which helps provide performance and investment protection.
- IBM Virtual Fabric offers up to four I/O ports on a single-wide blade and up to four I/O modules in a single chassis, with the choice of Ethernet, Fibre Channel, iSCSI, and SAS connectivity.
- BladeCenter E supports port speeds up to 8 Gbps.
- BladeCenter E provides up to 288 Gbps of external uplink bandwidth (full-duplex) with up to four IBM 1/10Gb Uplink Ethernet switches.
- A flexible and scalable architecture with integrated servers and networking, storage, and management infrastructure supports your growing business needs.
Manageability and security
Powerful systems management features simplify local and remote management of the BladeCenter E chassis:
- The high degree of integration in the BladeCenter E chassis reduces the need for server components, replacing numerous fans, KVM and Ethernet cables, power supplies, external switches, and other components.
- The BladeCenter E chassis includes the Advanced Management Module (AMM). The AMM boosts administrator productivity and reduces skill level requirements, which can help reduce costs, improve overall productivity, and make administration easier by providing a single point of control for the solution. The AMM supports many industry-standard open protocols.
- The AMM provides extensive security features, including role-based user authentication and access control, LDAP support, and SSH and SSL protocols for secure remote systems management.
- IBM Systems Director remains a powerful and intelligent solution to manage BladeCenter systems along side rack mount and tower servers. Systems Director uses the hardware’s capabilities by surfacing pertinent information about your blade server. The easy-to-use wizards provide step-by-step instructions and offer automated deployment capabilities.
- IBM Fabric Manager simplifies the deployment of infrastructure connections by managing network and storage address assignments.
Availability and serviceability
The BladeCenter E chassis provides many features to simplify serviceability and increase system uptime:
- BladeCenter reduces the number of parts that are required to run the system. By sharing fans, power supplies, systems management, and ports, there are fewer parts to buy and maintain, and fewer components that can fail and cause downtime.
- Hot-swap components, such as the server, switches, power modules, and blowers, ensure maximum uptime.
- Redundant components, such as blowers and power modules, ensure that systems can remain available even during hardware maintenance windows and failures.
- The Predictive Failure Analysis (PFA) detects when the system components operate outside of the standard thresholds and generates proactive alerts in advance of possible failure, therefore increasing uptime.
- Dual independent power and signal connectors to the BladeCenter E chassis midplane provide fault tolerance to increase uptime.
- The light path diagnostics panel and individual light path LEDs quickly lead the technician to failed (or failing) components. These features simplify servicing, speed up problem resolution, and improve system availability.
- Three-year customer replaceable unit and onsite limited warranty, with next business day 9x5, provides an additional peace of mind.
Energy efficiency
The BladeCenter E chassis offers the following energy-efficient features to save energy, reduce operational costs, increase energy availability, and contribute to a green environment:
- Energy-efficient components and the component-sharing design of the BladeCenter chassis provides ultimate power and cooling savings.
- The BladeCenter E helps reduce energy costs with high-efficiency power supplies.
- The BladeCenter E uses hexagonal ventilation holes, a part of the IBM Calibrated Vectored Cooling™ technology. Hexagonal holes can be grouped more densely than round holes, providing a more efficient airflow through the system, which helps reduce cooling costs.
- IBM Systems Director Active Energy Manager™ provides advanced power management features with actual real-time energy monitoring, reporting, and capping features.
Locations of key components
Figure 2 shows the front of the BladeCenter E chassis.
Figure 2. Front of the BladeCenter E chassis
Figure 3 shows the rear of the BladeCenter E chassis.
Figure 3. Rear of the BladeCenter E chassis
Standard specifications
Table 1 lists the standard specifications of the BladeCenter E chassis.
Components | Specification |
Machine type | x-config: 8677. |
Form factor | 7U rack-mounted unit. |
Server bays | 14. |
Servers supported | Intel Xeon processor-based HS12, HS22, HS22V, HS23, and HS23E servers IBM POWER® processor-based PS700 servers Certain older BladeCenter servers |
Standard I/O bays | Four (Bays 1 - 4). Support for 1 Gb Ethernet, 4 Gb and 8 Gb Fibre Channel, and 3 Gb SAS I/O modules. |
Connectivity type | Ethernet, Fibre Channel, iSCSI, and SAS. |
Management modules | Up to two redundant hot-swap Advanced Management Modules (AMM): One AMM standard, the second AMM optional. |
Optical drive bays | One. Support for an optional DVD-ROM or multi-burner. |
Ports | AMM: One DB-15 video port, two USB 2.0 ports for keyboard and mouse, one RJ-45 serial port, one RJ-45 10/100 Mb Ethernet port for remote management. Front: One USB 2.0 port. |
Cooling | IBM Calibrated Vectored Cooling with two redundant hot-swap blower modules. |
Power modules | Up to four redundant hot-swap 2000 W or 2320 W power modules support two power domains; redundancy is provided within a pair in the same power domain. Power modules 1 and 2 supply power to server bays 1 - 6; power modules 3 and 4 supply power to server bays 7 - 14. (See the "Power modules" section for details.) |
Hot-swap parts | Servers, I/O modules, management modules, power modules, and blowers. |
Systems management | AMM, light path diagnostics, Predictive Failure Analysis, IBM Systems Director, and IBM Systems Director Active Energy Manager. Remote presence (graphics, keyboard and mouse, and virtual media) through AMM. |
Security features | Role-based user security, LDAP, SSH, and SSL. |
Limited warranty | Three-year customer-replaceable unit and onsite limited warranty with 9x5/next business day response time. |
Service and support | Optional service upgrades are available through IBM ServicePacs: 9x5 or 24x7 4-hour or 2-hour response time, 1-year or 2-year warranty extension, remote technical support for IBM hardware and selected IBM and third-party (Microsoft, Linux, VMware) software. |
Dimensions | Height: 304 mm (12.0 in.), width: 444 mm (17.5 in.), depth: 711 mm (28.0 in.). |
Weight | Minimum: 39 kg (85 lb), maximum 102 kg (225 lb). |
Models
Table 2 lists the specifications of the standard BladeCenter E models.
Feature | Specifications | |
Machine type/model | 8677-3Tx†* | 8677-4Tx† |
Server bays (total / open) | 14 / 14 | 14 / 14 |
Management modules (std. / max.) | 1 / 2 | 1 / 2 |
Standard I/O bays (total / open) | 4 / 4 | 4 / 4 |
I/O modules standard | None | None |
Power supplies (std. / max.) | 2x 2000 W / 4 | 2x 2320 W / 4 |
Blowers (std. / max.) | 2 / 2 | 2 / 2 |
Optical drive | Optional | Optional |
† x is a region-specific letter (for example, EMEA MTM is 86774TG, and the US MTM is 86774TU).
* The model 3Tx is not available in EMEA.
Supported servers
Table 3 lists the blade servers that are supported in the BladeCenter E. The table also lists the maximum number of installable servers based on the thermal design power (TDP) of the Intel Xeon processor that is installed in the servers.
Blade server | CPU TDP | Maximum number of server per BladeCenter E chassis | |
---|---|---|---|
2000 W power supplies | 2320 W power supplies | ||
BladeCenter HS12 (8028) | All | 14 | 14 |
BladeCenter HS22 (7870) BladeCenter HS22V (7871) |
130 W | None | None |
95 W | 5+6 | 14 | |
80 W | 5+7 | 14 | |
60 W | 6+7 | 14 | |
40 W | 14 | 14 | |
BladeCenter HS23 (7875, E5-2600 v2) | Up to 130 W (excl. 80 W)† |
None | None |
80 W† | 6+7* | 14* | |
95 W# | 5+7*§ | 14*§ | |
70 W# | 14* | 14* | |
50 W# | 14 | 14 | |
BladeCenter HS23 (7875, E5-2600) | Up to 130 W (excl. 80 W)†† |
None | None |
80 W†† | 6+7 | 14 | |
95 W## | 5+7 | 14 | |
70 W## | 14 | 14 | |
BladeCenter HS23E (8038) | 95 W | 5+6 | 14 |
80 W | 5+7 | 14 | |
Up to 70 W | 14 | 14 | |
BladeCenter HX5 (7872 and 7873) | All | None | None |
BladeCenter PS700 | All | 14** | 14** |
BladeCenter PS701 | All | None | None |
BladeCenter PS702 | All | None | None |
BladeCenter PS703 | All | None | None |
BladeCenter PS704 | All | None | None |
† The support that is shown is for Intel Xeon standard thermal profile processors (all except Intel Xeon E5-2618L v2, E5-2628L v2, E5-2648L v2, and E5-2658 v2).
* When one blower fails, the HS23 (7875, E5-2600 v2) with specified processor TDP only supports ambient temperature of up to 28 °C when installed in the BladeCenter E chassis.
§ The HS23 (7875, E5-2600 v2) with the Intel Xeon processor E5-2658 v2 (95 W) only supports one DIMM per channel when installed in the BladeCenter E chassis.
†† The support that is shown is for Intel Xeon standard thermal profile processors (all except Intel Xeon E5-2648L and E5-2658).
# The support that is shown is for Intel Xeon robust thermal profile processors: Intel Xeon E5-2618L v2 (50 W), E5-2628L v2 (70 W), E5-2648L v2 (70 W), and E5-2658 v2 (95 W).
## The support that is shown is for Intel Xeon robust thermal profile processors: Intel Xeon E5-2648L (70 W) and E5-2658 (95 W).
** Only specific models of the BladeCenter E are supported by the PS700: 8677-3Sx, 4Sx, 3Tx, 4Tx.
For the latest information about the servers that are supported in the BladeCenter E chassis, see IBM ServerProven® at the following web address:
http://ibm.com/servers/eserver/serverproven/compat/us/
I/O architecture
The BladeCenter E chassis provides connection paths between the server blade bays and I/O bays through a hardwired dual redundant midplane.
Each blade bay has four dedicated I/O connections (two per midplane) linked to four I/O bays (one blade bay connection to one I/O bay). Thus, each I/O bay has a total of 14 I/O connections (to 14 blade bays). Figure 4 shows the I/O topology.
Figure 4. BladeCenter E I/O topology
Each blade server has at least two integrated Gigabit Ethernet ports (Ethernet 1 and Ethernet 2). Ethernet 1 is routed to I/O bay 1 and Ethernet 2 is routed to I/O bay 2, which means that only Ethernet-capable I/O modules can be used in I/O bays 1 and 2.
I/O expansion cards that you optionally install in blade servers have two ports, which are routed to I/O bays 3 and 4. Thus, depending on the expansion card that is installed, compatible I/O modules must be chosen for those I/O bays. Unless an expansion card is installed in one or more processor blades, there is no need for I/O modules 3 and 4.
The I/O modules must be compatible with the I/O interfaces present in the blade servers. For example, when a Fibre Channel expansion card is installed in a blade server, I/O modules 3 and 4 must also be Fibre Channel-based (that is, an FC switch module), and vice versa. If you install FC switches in bays 3 and 4, then any expansion cards that are installed in all other blade servers in the same chassis must be Fibre Channel.
Table 4 shows the connections between adapter slots in the compute nodes to the switch bays in the chassis.
I/O adapter in each server |
Port on the adapter | Corresponding I/O module bay in the chassis |
Onboard 1 Gb Ethernet | Port 1 | I/O bay 1 |
Port 2 | I/O bay 2 | |
CIOv adapter | Port 1 | I/O bay 3 |
Port 2 | I/O bay 4 |
Supported I/O modules
Tables 5 through 7 list the I/O modules that are supported by the BladeCenter E chassis and the corresponding I/O bay into which the I/O module can be installed.
I/O module | Part number | Feature code |
I/O bay number
|
|||
1
|
2
|
3
|
4
|
|||
Gigabit Ethernet | ||||||
Cisco Catalyst Switch Module 3012* | 43W4395 | 5450 | Y | Y | Y | Y |
Cisco Catalyst Switch Module 3012 | 46C9272 | A3FE | Y | Y | Y | Y |
Cisco Catalyst Switch Module 3110G* | 41Y8523 | 2989 | Y | Y | Y | Y |
Cisco Catalyst Switch Module 3110G | 00Y3254 | A3FD | Y | Y | Y | Y |
Cisco Catalyst Switch Module 3110X* | 41Y8522 | 2988 | Y | Y | Y | Y |
Cisco Catalyst Switch Module 3110X | 00Y3250 | A3FC | Y | Y | Y | Y |
IBM 1/10Gb Uplink Ethernet Switch Module | 44W4404 | 1590 | Y | Y | Y | Y |
IBM L2/3 Copper GbE Switch Module | 32R1860 | 1495 | Y | Y | Y | Y |
IBM L2/3 Fiber GbE Switch Module | 32R1861 | 1496 | Y | Y | Y | Y |
IBM L2-7 Gb Ethernet Switch Module | 32R1859 | 1494 | Y | Y | Y | Y |
IBM Server Connectivity Module | 39Y9324 | 1484 | Y | Y | Y | Y |
* Withdrawn, not available for ordering.
I/O module | Part number | Feature code |
I/O bay number
|
|||
1
|
2
|
3
|
4
|
|||
4 Gb Fibre Channel | ||||||
Cisco 4Gb 20 port FC Switch Module* | 39Y9280 | 2983 | N | N | Y | Y |
Cisco 4Gb 20 port FC Switch Module | 44E5696 | A3FH | N | N | Y | Y |
Cisco 4Gb 10 port FC Switch Module* | 39Y9284 | 2984 | N | N | Y | Y |
Cisco 4Gb 10 port FC Switch Module | 44E5692 | A3FG | N | N | Y | Y |
8 Gb Fibre Channel | ||||||
Brocade Enterprise 20-port 8Gb SAN Switch | 42C1828 | 5764 | N | N | Y | Y |
Brocade 20-port 8Gb SAN Switch Module | 44X1920 | 5481 | N | N | Y | Y |
Brocade 10-port 8Gb SAN Switch Module | 44X1921 | 5483 | N | N | Y | Y |
QLogic 20-Port 8Gb SAN Switch Module | 44X1905 | 5478 | N | N | Y | Y |
QLogic 20-Port 4/8Gb SAN Switch Module | 88Y6406 | A24C | N | N | Y | Y |
QLogic 8Gb Intelligent Pass-thru Module | 44X1907 | 5482 | N | N | Y | Y |
QLogic 4/8Gb Intelligent Pass-thru Module | 88Y6410 | A24D | N | N | Y | Y |
* Withdrawn, not available for ordering.
I/O module | Part number | Feature code |
I/O bay number
|
|||
1
|
2
|
3
|
4
|
|||
SAS modules | ||||||
SAS Connectivity Module | 39Y9195 | 2980 | N | N | Y | Y |
Pass-through modules | ||||||
Intelligent Copper Pass-thru Module | 44W4483 | 5452 | Y | Y | Y | Y |
For more information, see the following Lenovo Press Product Guides:
- Ethernet switches:
https://lenovopress.com/servers/blades/networkmodule - Fibre Channel switches:
https://lenovopress.com/servers/blades/storagemodule
Optical drives
The BladeCenter E supports one optical drive. The optical drive and USB port are available to any one blade server in the chassis. The drive and USB port cannot be shared among multiple servers. The drive and USB port can be used to install operating systems, update drivers, or to copy data to recordable media.
Table 8 lists the supported optical drives.
Part number | Feature code | Description | Maximum supported | Standard models where used |
46M0901 | 4161 | IBM UltraSlim Enhanced SATA DVD-ROM | 1 | - |
46M0902 | 4163 | IBM UltraSlim Enhanced SATA Multi-Burner | 1 | - |
IBM UltraSlim Enhanced SATA DVD-ROM (part number 46M0901) supports the following media and speeds for reading:
- CD-ROM 24X
- CD-R 24X
- CD-RW 24X
- DVD-ROM (4.7 GB) 8X
- DVD-ROM (dual layer, 8.5 GB) 8X
- DVD-R (4.7 GB) 8X
- DVD-R (dual layer, 8.5 GB) 8X
- DVD+R (4.7 GB) 8X
- DVD+R (dual layer, 8.5 GB) 8X
- DVD-RW (4.7 GB) 8X
- DVD+RW (4.7 GB) 8X
- DVD-RAM (4.7 GB) 5X
IBM UltraSlim Enhanced SATA Multi-Burner (46M0902) supports the same media and speeds for reading as DVD-ROM (46M0901). This drive also supports the following media and speeds for writing:
- CD-R 24X
- CD-RW 4X
- High Speed CD-RW 10X
- Ultra Speed CD-RW 24X
- Ultra Speed Plus CD-RW 24X
- DVD-R (4.7 GB) 8X
- DVD-R (dual layer, 8.5 GB) 6X
- DVD+R (4.7 GB) 8X
- DVD+R (dual layer, 8.5 GB) 6X
- DVD-RW (4.7 GB) 6X
- DVD+RW (4.7 GB) 8X
- DVD-RAM (4.7 GB) 5X
Remote management
Remote management functionality is provided by the Advanced Management Module (AMM). The AMM is a hot-swap module that you use to configure and manage all installed BladeCenter components. The AMM provides system management functions and KVM multiplexing for all blade servers in the BladeCenter unit that support KVM. It controls a serial port for remote connection, the external keyboard, mouse, and video connections for use by a local console, and a 10/100 Mbps Ethernet remote management connection.
The BladeCenter E chassis comes standard with at least one AMM, and it supports up to two redundant hot-swap AMMs in an active/standby configuration. Table 9 shows the AMM ordering information.
Part number | Feature code | Description |
2019A1X | 1604 | Advanced Management Module for BladeCenter |
Important: Older BladeCenter E chassis were shipped with the Standard Management Module. If your existing BladeCenter E chassis has the Standard Management Module, then you might need to replace it with the AMM to support newer blades, I/O modules, and software functions that are used in this chassis.
Figure 5 shows the Advanced Management Module.
Figure 5. Advanced Management Module
The following tasks can be performed with AMM:
- Defining the login IDs and passwords
- Configuring security settings, such as data encryption and user account security
- Selecting recipients for alert notification about specific events
- Monitoring the status of the BladeCenter unit, blade servers, and other BladeCenter components:
- Event log
- LEDs
- Hardware and firmware VPD
- Fan speeds
- Temperatures
- Power usage
- Discovering other BladeCenter units in the network and enabling access to them through their management-module web interfaces
- Controlling the BladeCenter unit, blade servers, and other BladeCenter components:
- Power on/off
- Firmware update
- Configuration settings
- Serial over LAN
- Configuring power management for BladeCenter unit
- Accessing the I/O modules to configure them
- Changing the startup sequence in a blade server
- Setting the date and time
- Using a remote console for the blade servers
- Mounting remote virtual media for the blade servers
- Changing ownership of the keyboard, video, and mouse
- Changing ownership of the removable-media drives and USB ports (The removable-media drives in the BladeCenter unit are viewed as USB devices by the blade server operating system.)
- Using IBM Fabric Manager functions
- Using Service Advisor functions to autonomously inform IBM Support about any critical events that happen
AMM supports the following management methods:
- Web-based interface with SSL support
- CLI through Telnet/SSH
- SMASH Command Line Protocol
- SNMP
For more information about AMM, see the following product documentation:
- BladeCenter Advanced Management Module Installation Guide, found at:
http://ibm.com/support/entry/portal/docdisplay?lndocid=MIGR-5073392 - BladeCenter Advanced Management Module User's Guide, found at:
http://ibm.com/support/entry/portal/docdisplay?lndocid=MIGR-5073887 - Advanced Management Module Command Line Interface Reference Guide, found at:
http://ibm.com/support/entry/portal/docdisplay?lndocid=MIGR-54667
Power modules
The BladeCenter E unit comes with one pair of 2000 W or 2320 W (model-dependent) hot-swap power modules in power module bays 1 and 2, and with two IEC 320-C19 to C20 power cables. Each power module has its own IEC 320-C20 power connector.
The power modules in bays 1 and 2 provide power to all the I/O and management modules and to blade bays 1 - 6. The power modules in bays 3 and 4 provide power to blade bays 7 - 14.
Table 10 shows the ordering information for power modules (each part number contains two power modules and two IEC 320-C19 to C20 power cables).
Part number | Feature code | Description |
39M4675 | 2105 | BladeCenter E 2000 W Power Supply Modules |
46M0508 | 2106 | BladeCenter E 2320 W Power Supply Option* |
* This option requires the AMM.
Important:
- Because the existing chassis might have lower capacity power supplies (1200, 1400, 1800, or 2000 W), ensure that the pair of power modules in the same power domain has the same capacity.
- When you use 2320 W power modules in a BladeCenter E Type 8677 unit, all power modules must be 2320 W modules.
- 2320 W power module field replaceable units (FRUs) may be listed as either 2320 W or 2500 W part on the power supply label and in the AMM. These power supplies can be used interchangeably in the same power domain.
Acoustic attenuation module
The Acoustic Attenuation Module is an option for BladeCenter E that you can install over the blower modules in the rear of the chassis to reduce decibels in sound-sensitive environments. BladeCenter E generates 74 decibels (7.4 bels) at maximum performance levels. The Acoustic Attenuation Module reduces the decibel level to 69 decibels by using a T-shaped baffle.
Table 11 lists the optional acoustic attenuation module that can be ordered for the BladeCenter E chassis.
Part number | Feature code | Description |
39M4674 | 0965 | BladeCenter Acoustic Attenuation Module |
Physical and electrical specifications
Dimensions and weight (approximate):
- Height: 304 mm (12.0 in.)
- Width: 444 mm (17.5 in.)
- Depth: 711 mm (28.0 in.)
- Weight:
- Minimum configuration: 39 kg (85 lb)
- Maximum configuration: 102 kg (225 lb)
Supported environment:
- Temperature and humidity:
- 10.0 - 35.0 degrees C (50 - 95 degrees F) at 0 - 914 m (0 - 3,000 ft)
- 10.0 - 32.0 degrees C (50 - 90 degrees F) at 914 - 2,133 m (3,000 - 7,000 ft)
- Relative humidity: 8% - 80%
- Maximum altitude: 2,133 m (7,000 ft)
- Supported electrical input:
- 200 - 240 (nominal) V ac; 50 Hz or 60 Hz
- Input kilovolt-amperes (kVA) (approximately):
- Minimum configuration: 0.4 kVA
- Maximum configuration:
- 2000 W power supplies: 6.0 kVA
- 2320 W power supplies: 7.0 kVA
- BTU output:
- Minimum configuration: 1365 Btu/hr (400 watts)
- Maximum configuration:
- 2000 W power supplies: 20094 Btu/hr (5889 watts)
- 2320 W power supplies: 23672 Btu/hr (6938 watts)
- Acoustical noise emissions:
- Declared sound power level without acoustic attenuation module: 7.4 bels
- Declared sound power level with acoustic attenuation module: 6.9 bels
Warranty options
The BladeCenter E has a three-year onsite warranty with 9x5 next-business-day terms. IBM offers the warranty service upgrades through IBM ServicePac®, which is described in this section. The IBM ServicePac is a series of prepackaged warranty maintenance upgrades and post-warranty maintenance agreements with a well-defined scope of services, including service hours, response time, term of service, and service agreement terms and conditions.
IBM ServicePac offerings are country-specific. That is, each country might have its own service types, service levels, response times, and terms and conditions. Not all covered types of ServicePac might be available in a particular country. For more information about the IBM ServicePac offerings that are available in your country, see the IBM ServicePac Product Selector at https://www-304.ibm.com/sales/gss/download/spst/servicepac.
Table 12 explains warranty service definitions in more detail.
Term | Description |
IBM onsite repair (IOR) | A service technician comes to the server's location for equipment repair. |
24x7x2 hour | A service technician is scheduled to arrive at your client’s location within two hours after remote problem determination is completed. We provide 24-hour service, every day, including IBM holidays. |
24x7x4 hour | A service technician is scheduled to arrive at your client’s location within four hours after remote problem determination is completed. We provide 24-hour service, every day, including IBM holidays. |
9x5x4 hour | A service technician is scheduled to arrive at your client’s location within four business hours after remote problem determination is completed. We provide service from 8:00 a.m. to 5:00 p.m. in the client's local time zone, Monday through Friday, excluding IBM holidays. If it is after 1:00 p.m., and it is determined that onsite service is required, the client can expect the service technician to arrive the morning of the following business day. For noncritical service requests, a service technician will arrive by the end of the following business day. |
9x5 next business day | A service technician is scheduled to arrive at your client’s location on the business day after we receive your call, following remote problem determination. We provide service from 8:00 a.m. to 5:00 p.m. in the client's local time zone, Monday through Friday, excluding IBM holidays. |
In general, the following types are the types of IBM ServicePacs that are available for the BladeCenter E:
- Warranty and maintenance service upgrades:
- One, two, three, four, or five years of 9x5 or 24x7 service coverage
- Onsite repair from the next business day to four or two hours
- One or two years of warranty extension
- Remote technical support services:
- One or three years with 24x7 coverage (severity 1) or 9x5/next business day for all severities
- Installation and startup support for System x® servers
- Remote technical support for System x servers
- Software support - Support Line:
- Microsoft or Linux software
- VMware
- IBM Director
Regulatory compliance
The chassis conforms to the following regulations:
- FCC - Verified to comply with Part 15 of the FCC Rules, Class A
- Canada ICES-003, Class A
- UL 60950
- CSA C22.2 No. 60950
- NOM-019
- Japan VCCI, Class A
- EN55022 Class A
- CISPR 22, Class A
External disk storage systems
Lenovo offers the ThinkSystem DE Series and ThinkSystem DM Series external storage systems for high-performance storage. See the DE Series and DM Series product guides for specific controller models, expansion enclosures and configuration options:
- ThinkSystem DE Series Storage
https://lenovopress.com/storage/thinksystem/de-series#rt=product-guide - ThinkSystem DM Series Storage
https://lenovopress.com/storage/thinksystem/dm-series#rt=product-guide - ThinkSystem DG Series Storage
https://lenovopress.com/storage/thinksystem/dg-series#rt=product-guide
External backup units
The following table lists the external backup options that are offered by Lenovo.
Part number | Description |
---|---|
External RDX USB drives | |
4T27A10725 | ThinkSystem RDX External USB 3.0 Dock |
External SAS tape backup drives | |
6160S7E | IBM TS2270 Tape Drive Model H7S |
6160S8E | IBM TS2280 Tape Drive Model H8S |
6160S9E | IBM TS2290 Tape Drive Model H9S |
External SAS tape backup autoloaders | |
6171S7R | IBM TS2900 Tape Autoloader w/LTO7 HH SAS |
6171S8R | IBM TS2900 Tape Autoloader w/LTO8 HH SAS |
6171S9R | IBM TS2900 Tape Autoloader w/LTO9 HH SAS |
External tape backup libraries | |
6741A1F | IBM TS4300 3U Tape Library-Base Unit |
6741A3F | IBM TS4300 3U Tape Library-Expansion Unit |
Full High 8 Gb Fibre Channel for TS4300 | |
01KP938 | LTO 7 FH Fibre Channel Drive |
01KP954 | LTO 8 FH Fibre Channel Drive |
02JH837 | LTO 9 FH Fibre Channel Drive |
Half High 8 Gb Fibre Channel for TS4300 | |
01KP936 | LTO 7 HH Fibre Channel Drive |
01KP952 | LTO 8 HH Fibre Channel Drive |
02JH835 | LTO 9 HH Fibre Channel Drive |
Half High 6 Gb SAS for TS4300 | |
01KP937 | LTO 7 HH SAS Drive |
01KP953 | LTO 8 HH SAS Drive |
02JH836 | LTO 9 HH SAS Drive |
For more information, see the list of Product Guides in the Backup units category:
https://lenovopress.com/servers/options/backup
Top-of-rack Ethernet switches
The following table lists the Ethernet LAN switches that are offered by Lenovo.
Part number | Description |
---|---|
1 Gb Ethernet Rack switches | |
7Y810011WW | Lenovo ThinkSystem NE0152T RackSwitch (Rear to Front) |
7Z320O11WW | Lenovo ThinkSystem NE0152TO RackSwitch (Rear to Front, ONIE) |
7159BAX | Lenovo RackSwitch G7028 (Rear to Front) |
7159CAX | Lenovo RackSwitch G7052 (Rear to Front) |
7159G52 | Lenovo RackSwitch G8052 (Rear to Front) |
7165H1X | Juniper EX2300-C PoE Switch |
7165H2X | Juniper EX2300-24p PoE Switch |
1 Gb Ethernet Campus switches | |
7Z340011WW | Lenovo CE0128TB Switch (3-Year Warranty) |
7Z360011WW | Lenovo CE0128TB Switch (Limited Lifetime Warranty) |
7Z340012WW | Lenovo CE0128PB Switch (3-Year Warranty) |
7Z360012WW | Lenovo CE0128PB Switch (Limited Lifetime Warranty) |
7Z350021WW | Lenovo CE0152TB Switch (3-Year Warranty) |
7Z370021WW | Lenovo CE0152TB Switch (Limited Lifetime Warranty) |
7Z350022WW | Lenovo CE0152PB Switch (3-Year Warranty) |
7Z370022WW | Lenovo CE0152PB Switch (Limited Lifetime Warranty) |
10 Gb Ethernet switches | |
7159A1X | Lenovo ThinkSystem NE1032 RackSwitch (Rear to Front) |
7159B1X | Lenovo ThinkSystem NE1032T RackSwitch (Rear to Front) |
7Z330O11WW | Lenovo ThinkSystem NE1064TO RackSwitch (Rear to Front, ONIE) |
7159C1X | Lenovo ThinkSystem NE1072T RackSwitch (Rear to Front) |
7159CRW | Lenovo RackSwitch G8272 (Rear to Front) |
7159GR6 | Lenovo RackSwitch G8296 (Rear to Front) |
7159BR6 | Lenovo RackSwitch G8124E (Rear to Front) |
25 Gb Ethernet switches | |
7159E1X | Lenovo ThinkSystem NE2572 RackSwitch (Rear to Front) |
7Z210O21WW | Lenovo ThinkSystem NE2572O RackSwitch (Rear to Front, ONIE) |
7Z330O21WW | Lenovo ThinkSystem NE2580O RackSwitch (Rear to Front, ONIE) |
100 Gb Ethernet switches | |
7159D1X | Lenovo ThinkSystem NE10032 RackSwitch (Rear to Front) |
7Z210O11WW | Lenovo ThinkSystem NE10032O RackSwitch (Rear to Front, ONIE) |
For more information, see the list of Product Guides in the following switch categories:
- 1 Gb Ethernet switches: http://lenovopress.com/networking/tor/1gb?rt=product-guide
- 10 Gb Ethernet switches: http://lenovopress.com/networking/tor/10gb?rt=product-guide
- 25 Gb Ethernet switches: http://lenovopress.com/networking/tor/25gb?rt=product-guide
- 40 Gb Ethernet switches: http://lenovopress.com/networking/tor/40gb?rt=product-guide
- 100 Gb Ethernet switches: https://lenovopress.com/networking/tor/100Gb?rt=product-guide
Power distribution units
The following table lists the power distribution units (PDUs) that are offered by Lenovo.
Part number |
Feature code |
Description |
ANZ
|
ASEAN
|
Brazil
|
EET
|
MEA
|
RUCIS
|
WE
|
HTK
|
INDIA
|
JAPAN
|
LA
|
NA
|
PRC
|
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
0U Basic PDUs | |||||||||||||||
4PU7A93176 | C0QH | 0U 36 C13 and 6 C19 Basic 32A 1 Phase PDU v2 | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
4PU7A93169 | C0DA | 0U 36 C13 and 6 C19 Basic 32A 1 Phase PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
4PU7A93177 | C0QJ | 0U 24 C13/C15 and 24 C13/C15/C19 Basic 32A 3 Phase WYE PDU v2 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
4PU7A93170 | C0D9 | 0U 24 C13/C15 and 24 C13/C15/C19 Basic 32A 3 Phase WYE PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
00YJ776 | ATZY | 0U 36 C13/6 C19 24A 1 Phase PDU | N | Y | Y | N | N | N | N | N | N | Y | Y | Y | N |
00YJ779 | ATZX | 0U 21 C13/12 C19 48A 3 Phase PDU | N | N | Y | N | N | N | Y | N | N | Y | Y | Y | N |
00YJ777 | ATZZ | 0U 36 C13/6 C19 32A 1 Phase PDU | Y | Y | N | Y | Y | Y | Y | Y | Y | N | N | Y | Y |
00YJ778 | AU00 | 0U 21 C13/12 C19 32A 3 Phase PDU | Y | Y | N | Y | Y | Y | Y | Y | Y | N | N | Y | Y |
0U Switched and Monitored PDUs | |||||||||||||||
4PU7A93181 | C0QN | 0U 21 C13/C15 and 21 C13/C15/C19 Switched and Monitored 48A 3 Phase Delta PDU V2 (60A derated) | N | Y | N | N | N | N | N | Y | N | Y | N | Y | N |
4PU7A93174 | C0D5 | 0U 21 C13/C15 and 21 C13/C15/C19 Switched and Monitored 48A 3 Phase Delta PDU (60A derated) | N | Y | N | Y | N | N | Y | Y | N | N | N | Y | N |
4PU7A93178 | C0QK | 0U 20 C13 and 4 C19 Switched and Monitored 32A 1 Phase PDU v2 | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
4PU7A93171 | C0D8 | 0U 20 C13 and 4 C19 Switched and Monitored 32A 1 Phase PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
4PU7A93182 | C0QP | 0U 18 C13/C15 and 18 C13/C15/C19 Switched and Monitored 63A 3 Phase WYE PDU v2 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
4PU7A93175 | C0CS | 0U 18 C13/C15 and 18 C13/C15/C19 Switched and Monitored 63A 3 Phase WYE PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
4PU7A93180 | C0QM | 0U 18 C13/C15 and 18 C13/C15/C19 Switched and Monitored 32A 3 Phase WYE PDU v2 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
4PU7A93173 | C0D6 | 0U 18 C13/C15 and 18 C13/C15/C19 Switched and Monitored 32A 3 Phase WYE PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
4PU7A93179 | C0QL | 0U 16 C13/C15 and 16 C13/C15/C19 Switched and Monitored 24A 1 Phase PDU v2 (30A derated) | N | Y | N | N | N | N | N | Y | N | Y | N | Y | N |
4PU7A93172 | C0D7 | 0U 16 C13/C15 and 16 C13/C15/C19 Switched and Monitored 24A 1 Phase PDU(30A derated) | N | Y | N | Y | N | N | Y | Y | N | N | N | Y | N |
00YJ783 | AU04 | 0U 12 C13/12 C19 Switched and Monitored 48A 3 Phase PDU | N | N | Y | N | N | N | Y | N | N | Y | Y | Y | N |
00YJ781 | AU03 | 0U 20 C13/4 C19 Switched and Monitored 24A 1 Phase PDU | N | N | Y | N | Y | N | Y | N | N | Y | Y | Y | N |
00YJ782 | AU02 | 0U 18 C13/6 C19 Switched and Monitored 32A 3 Phase PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | N | Y |
00YJ780 | AU01 | 0U 20 C13/4 C19 Switched and Monitored 32A 1 Phase PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | N | Y |
1U Switched and Monitored PDUs | |||||||||||||||
4PU7A90808 | C0D4 | 1U 18 C19/C13 Switched and monitored 48A 3P WYE PDU V2 ETL | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
4PU7A81117 | BNDV | 1U 18 C19/C13 switched and monitored 48A 3P WYE PDU - ETL | N | N | N | N | N | N | N | N | N | N | N | Y | N |
4PU7A90809 | C0DE | 1U 18 C19/C13 Switched and monitored 48A 3P WYE PDU V2 CE | N | N | N | N | N | Y | Y | N | N | N | N | N | N |
4PU7A81118 | BNDW | 1U 18 C19/C13 switched and monitored 48A 3P WYE PDU - CE | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | N | Y |
4PU7A90810 | C0DD | 1U 18 C19/C13 Switched and monitored 80A 3P Delta PDU V2 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
4PU7A77467 | BLC4 | 1U 18 C19/C13 Switched and Monitored 80A 3P Delta PDU | N | N | N | N | N | N | N | N | N | Y | N | Y | N |
4PU7A90811 | C0DC | 1U 12 C19/C13 Switched and monitored 32A 3P WYE PDU V2 | N | N | N | N | N | Y | Y | N | N | N | N | N | N |
4PU7A77468 | BLC5 | 1U 12 C19/C13 switched and monitored 32A 3P WYE PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
4PU7A90812 | C0DB | 1U 12 C19/C13 Switched and monitored 60A 3P Delta PDU V2 | N | N | N | N | N | N | N | N | N | Y | N | N | N |
4PU7A77469 | BLC6 | 1U 12 C19/C13 switched and monitored 60A 3P Delta PDU | N | N | N | N | N | N | N | N | N | N | N | Y | N |
46M4002 | 5896 | 1U 9 C19/3 C13 Switched and Monitored DPI PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
46M4004 | 5894 | 1U 12 C13 Switched and Monitored DPI PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
46M4003 | 5897 | 1U 9 C19/3 C13 Switched and Monitored 60A 3 Phase PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
46M4005 | 5895 | 1U 12 C13 Switched and Monitored 60A 3 Phase PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
1U Ultra Density Enterprise PDUs (9x IEC 320 C13 + 3x IEC 320 C19 outlets) | |||||||||||||||
71763NU | 6051 | Ultra Density Enterprise C19/C13 PDU 60A/208V/3PH | N | N | Y | N | N | N | N | N | N | Y | Y | Y | N |
71762NX | 6091 | Ultra Density Enterprise C19/C13 PDU Module | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
1U C13 Enterprise PDUs (12x IEC 320 C13 outlets) | |||||||||||||||
39M2816 | 6030 | DPI C13 Enterprise PDU Plus Module (WW) | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
39Y8941 | 6010 | DPI C13 Enterprise PDU Module (WW) | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
1U C19 Enterprise PDUs (6x IEC 320 C19 outlets) | |||||||||||||||
39Y8948 | 6060 | DPI C19 Enterprise PDU Module (WW) | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
39Y8923 | 6061 | DPI Three-phase 60A/208V C19 Enterprise PDU (US) | N | N | Y | N | N | N | Y | N | N | N | Y | Y | N |
1U Front-end PDUs (3x IEC 320 C19 outlets) | |||||||||||||||
39Y8938 | 6002 | DPI Single-phase 30A/120V Front-end PDU (US) | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
39Y8939 | 6003 | DPI Single-phase 30A/208V Front-end PDU (US) | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
39Y8934 | 6005 | DPI Single-phase 32A/230V Front-end PDU (International) | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
39Y8940 | 6004 | DPI Single-phase 60A/208V Front-end PDU (US) | Y | N | Y | Y | Y | Y | Y | N | N | Y | Y | Y | N |
39Y8935 | 6006 | DPI Single-phase 63A/230V Front-end PDU (International) | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
1U NEMA PDUs (6x NEMA 5-15R outlets) | |||||||||||||||
39Y8905 | 5900 | DPI 100-127V NEMA PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Line cords for 1U PDUs that ship without a line cord | |||||||||||||||
40K9611 | 6504 | 4.3m, 32A/380-415V, EPDU/IEC 309 3P+N+G 3ph wye (non-US) Line Cord | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
40K9612 | 6502 | 4.3m, 32A/230V, EPDU to IEC 309 P+N+G (non-US) Line Cord | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
40K9613 | 6503 | 4.3m, 63A/230V, EPDU to IEC 309 P+N+G (non-US) Line Cord | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
40K9614 | 6500 | 4.3m, 30A/208V, EPDU to NEMA L6-30P (US) Line Cord | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
40K9615 | 6501 | 4.3m, 60A/208V, EPDU to IEC 309 2P+G (US) Line Cord | N | N | Y | N | N | N | Y | N | N | Y | Y | Y | N |
40K9617 | 6505 | 4.3m, 32A/230V, Souriau UTG Female to AS/NZ 3112 (Aus/NZ) Line Cord | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
40K9618 | 6506 | 4.3m, 32A/250V, Souriau UTG Female to KSC 8305 (S. Korea) Line Cord | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
For more information, see the Lenovo Press documents in the PDU category:
https://lenovopress.com/servers/options/pdu
Uninterruptible power supply units
The following table lists the uninterruptible power supply (UPS) units that are offered by Lenovo.
Part number | Description |
---|---|
Rack-mounted or tower UPS units - 100-125VAC | |
7DD5A001WW | RT1.5kVA 2U Rack or Tower UPS-G2 (100-125VAC) |
55941AX | RT1.5kVA 2U Rack or Tower UPS (100-125VAC) |
55942AX | RT2.2kVA 2U Rack or Tower UPS (100-125VAC) |
7DD5A003WW | RT3kVA 2U Rack or Tower UPS-G2 (100-125VAC) |
55943AX | RT3kVA 2U Rack or Tower UPS (100-125VAC) |
Rack-mounted or tower UPS units - 200-240VAC | |
7DD5A002WW | RT1.5kVA 2U Rack or Tower UPS-G2 (200-240VAC) |
55941KX | RT1.5kVA 2U Rack or Tower UPS (200-240VAC) |
55942KX | RT2.2kVA 2U Rack or Tower UPS (200-240VAC) |
7DD5A005WW | RT3kVA 2U Rack or Tower UPS-G2 (200-240VAC) |
55943KX | RT3kVA 2U Rack or Tower UPS (200-240VAC) |
7DD5A007WW | RT5kVA 3U Rack or Tower UPS-G2 (200-240VAC) |
55945KX | RT5kVA 3U Rack or Tower UPS (200-240VAC) |
7DD5A008WW | RT6kVA 3U Rack or Tower UPS-G2 (200-240VAC) |
55946KX | RT6kVA 3U Rack or Tower UPS (200-240VAC) |
55948KX | RT8kVA 6U Rack or Tower UPS (200-240VAC) |
7DD5A00AWW | RT11kVA 6U Rack or Tower UPS-G2 (200-240VAC) |
55949KX | RT11kVA 6U Rack or Tower UPS (200-240VAC) |
55943KT† | ThinkSystem RT3kVA 2U Standard UPS (200-230VAC) (2x C13 10A, 2x GB 10A, 1x C19 16A outlets) |
55943LT† | ThinkSystem RT3kVA 2U Long Backup UPS (200-230VAC) (2x C13 10A, 2x GB 10A, 1x C19 16A outlets) |
55946KT† | ThinkSystem RT6kVA 5U UPS (200-230VAC) (2x C13 10A outlets, 1x Terminal Block output) |
5594XKT† | ThinkSystem RT10kVA 5U UPS (200-230VAC) (2x C13 10A outlets, 1x Terminal Block output) |
Rack-mounted or tower UPS units - 380-415VAC | |
55948PX | RT8kVA 6U 3:1 Phase Rack or Tower UPS (380-415VAC) |
55949PX | RT11kVA 6U 3:1 Phase Rack or Tower UPS (380-415VAC) |
† Only available in China and the Asia Pacific market.
For more information, see the list of Product Guides in the UPS category:
https://lenovopress.com/servers/options/ups
Rack cabinets
The BladeCenter E chassis is supported in the rack cabinets that are listed in Table 18.
Part number | Description |
201886X | IBM 11U Office Enablement Kit |
93072PX | IBM 25U Static S2 Standard Rack |
93072RX | IBM 25U Standard Rack |
93072SX | IBM 25U Standard Rack |
93074EX | IBM 42U Standard Rack Extension |
93074RX | IBM 42U Standard Rack |
93074SX | IBM 42U Standard Rack |
93074XX | IBM 42U Standard Rack Extension |
930842E | NetBAY42 Enterprise Expansion Rack Cabinet (EX) |
930842S | NetBAY42 Enterprise Rack Cabinet |
93084EX | IBM 42U Enterprise Expansion Rack |
93084PX | IBM 42U Enterprise Rack |
93084RX | NetBAY42 Enterprise Rack Cabinet |
93084XX | NetBAY42 Enterprise Expansion Rack Cabinet (EX) |
93604EX | IBM 42U 1200mm Deep Dynamic Expansion Rack |
93604PX | IBM 42U 1200mm Deep Dynamic Rack |
93614EX | IBM 42U 1200mm Deep Static Expansion Rack |
93614PX | IBM 42U 1200mm Deep Static Rack |
93624EX | IBM 47U 1200mm Deep Static Expansion Rack |
93624PX | IBM 47U 1200mm Deep Static Rack |
93634CX | IBM PureFlex™ System 42U Rack |
93634DX | IBM PureFlex System 42U Expansion Rack |
93634EX | IBM 42U 1100mm Dynamic Expansion Rack |
93634PX | IBM 42U 1100mm Dynamic Rack |
99564RX | IBM S2 42U Dynamic Standard Rack |
99564XX | IBM S2 42U Dynamic Standard Expansion Rack |
For more information, see the list of Lenovo Press Product Guides in the Rack cabinets and options category at https://lenovopress.com/servers/options/racks
Rack options
The BladeCenter E chassis supports the rack console switches and monitor kits that are listed in Table 19.
Part number | Description |
Monitor kits and keyboard trays | |
172317X | 1U 17in Flat Panel Console Kit |
172319X | 1U 19in Flat Panel Console Kit |
Console switches | |
1754D2X | IBM Global 4x2x32 Console Manager (GCM32) |
1754D1X | IBM Global 2x2x16 Console Manager (GCM16) |
1754A2X | IBM Local 2x16 Console Manager (LCM16) |
1754A1X | IBM Local 1x8 Console Manager (LCM8) |
Rack conversion options | |
46M5382 | IBM Serial Conversion Option (SCO) |
46M5383 | IBM Virtual Media Conversion Option Gen2 (VCO2) |
39M2895 | IBM USB Conversion Option (UCO) |
For more information, see the list of Lenovo Press Product Guides in the KVM Switches & Consoles category at https://lenovopress.com/servers/options/kvm
Lenovo Financial Services
Why wait to obtain the technology you need now? No payments for 90 days and predictable, low monthly payments make it easy to budget for your Lenovo solution.
- Flexible
Our in-depth knowledge of the products, services and various market segments allows us to offer greater flexibility in structures, documentation and end of lease options.
- 100% Solution Financing
Financing your entire solution including hardware, software, and services, ensures more predictability in your project planning with fixed, manageable payments and low monthly payments.
- Device as a Service (DaaS)
Leverage latest technology to advance your business. Customized solutions aligned to your needs. Flexibility to add equipment to support growth. Protect your technology with Lenovo's Premier Support service.
- 24/7 Asset management
Manage your financed solutions with electronic access to your lease documents, payment histories, invoices and asset information.
- Fair Market Value (FMV) and $1 Purchase Option Leases
Maximize your purchasing power with our lowest cost option. An FMV lease offers lower monthly payments than loans or lease-to-own financing. Think of an FMV lease as a rental. You have the flexibility at the end of the lease term to return the equipment, continue leasing it, or purchase it for the fair market value. In a $1 Out Purchase Option lease, you own the equipment. It is a good option when you are confident you will use the equipment for an extended period beyond the finance term. Both lease types have merits depending on your needs. We can help you determine which option will best meet your technological and budgetary goals.
Ask your Lenovo Financial Services representative about this promotion and how to submit a credit application. For the majority of credit applicants, we have enough information to deliver an instant decision and send a notification within minutes.
Trademarks
Lenovo and the Lenovo logo are trademarks or registered trademarks of Lenovo in the United States, other countries, or both. A current list of Lenovo trademarks is available on the Web at https://www.lenovo.com/us/en/legal/copytrade/.
The following terms are trademarks of Lenovo in the United States, other countries, or both:
Lenovo®
BladeCenter®
ServerProven®
System x®
ThinkSystem®
The following terms are trademarks of other companies:
Intel® and Xeon® are trademarks of Intel Corporation or its subsidiaries.
Linux® is the trademark of Linus Torvalds in the U.S. and other countries.
Microsoft® is a trademark of Microsoft Corporation in the United States, other countries, or both.
Other company, product, or service names may be trademarks or service marks of others.