Author
Updated
18 Feb 2021Form Number
LP0494PDF size
32 pages, 396 KB* Only available in selected markets
Abstract
The QLogic Enhanced Generation 5 (Gen 5) 16 Gb Fibre Channel (FC) Single and Dual-port Host Bus Adapters (HBAs) offer industry leading native FC performance with extremely low CPU usage with full hardware offloads. Enhanced Gen 5 FC technology provides advanced storage networking features capable of supporting the most demanding virtualized and private cloud environments, while fully leveraging the capabilities of high-performance 16 Gb FC (16GFC) and all-flash arrays (AFAs).
This product guide describes the QLogic HBAs for Lenovo System x servers and provides essential pre-sales information to understand the products, their key features and specifications, and compatibility. This guide is intended for technical specialists, sales specialists, sales engineers, and IT architects who want to learn more about the adapters and consider their use in IT solutions.
Change History
Changes in the February 18, 2021 update:
- The adapter supports the FC-NVMe (NVMe over Fibre Channel) protocol - Key features section
- The server support tables are now automatically updated - Server support section
Learn about the key features of the QLogic adapters
Introduction
The QLogic Enhanced Generation 5 (Gen 5) 16 Gb Fibre Channel (FC) Single and Dual-port Host Bus Adapters (HBAs) for Lenovo ThinkSystem and System x servers offer industry leading native FC performance with extremely low CPU usage with full hardware offloads.
Enhanced Gen 5 FC technology provides advanced storage networking features capable of supporting the most demanding virtualized and private cloud environments, while fully leveraging the capabilities of high-performance 16 Gb FC (16GFC) and all-flash arrays (AFAs). Powerful management tools automate and simplify SAN provisioning to help reduce cost and complexity, while the unmatched 16 Gbps performance eliminates potential I/O bottlenecks in today’s powerful multiprocessor, multicore servers.
The QLogic Enhanced Gen 5 16 Gb FC HBAs are shown in the following figure.
Figure 1. QLogic Enhanced Gen 5 16 Gb FC Single-port and Dual-port HBAs ( shown without the included SFP+ modules )
Did you know?
The QLogic StorFusion architecture delivers ultimate reliability to meet the needs of mission-critical enterprise applications with lower power and fewer CPU cycles, all while maintaining peak performance.
The QLogic Enhanced 16 Gb FC HBAs are based on our 32 Gbps Architecture, which delivers higher IOPS and performance with lower power consumption compared to previous generation.
QLogic QConvergeConsole provides unified, single-pane-of-glass management across generations of QLogic FC adapters.
Part number information
The following table lists the ordering information for the QLogic Enhanced 16 Gb FC HBAs.
Part number | Feature code | Description |
---|---|---|
01CV750 | ATZB | QLogic 16Gb FC Single-port HBA (Enhanced Gen 5) |
01CV760 | ATZC | QLogic 16Gb FC Dual-port HBA (Enhanced Gen 5) |
The part numbers for the QLogic Enhanced Gen 5 16 Gb FC HBAs include the following items:
- An FC HBA adapter with one or two 16 Gb (16/8/4 Gbps speeds) FC SW SFP+ installed
- 3U (standard) and 2U (low-profile) adapter brackets
- Publications package
Fiber optic cables
The following table lists the fiber optic cables that are available from Lenovo.
Key features
The QLogic Enhanced Gen 5 16 Gb FC HBAs have the following features:
- Maximum performance with up to 1.3 million input/output operations per second (IOPS) to support larger server virtualization deployments and scalable cloud initiatives, and performance to match new multicore processors, SSDs/flash storage, and faster server host bus architectures.
- Independent function, transmit and receive buffers, an on-chip CPU, DMA channels, and a firmware image for each port enable complete port-level isolation, prevent errors and firmware crashes from propagating across all ports, and provide predictable and scalable performance across all ports.
- Support for NVMe over Fibre Channel (FC-NVMe). The adapters support low-latency access to scale out NVMe with full support for the FC-NVMe protocol. The adapters can simultaneously support FC-NVMe and FCP-SCSI storage traffic on the same physical port, enabling customers to migrate to NVMe at their own pace.
-
Supports forward error correction (FEC) to enhance reliability of transmission and thereby performance.
-
Industry-standard class-specific control (CS_CTL)-based frame prioritization Quality of Service (QoS) helps alleviate network congestion by prioritizing traffic for time-sensitive mission critical workloads for optimized performance.
- T10-PI data integrity with high performance offload provides end-to-end data corruption protection.
- Support for Message Signaled Interrupts eXtended (MSI-X) improves host utilization and enhances application performance.
-
Fabric-assigned port worldwide name (FA-WWN) and fabric-based boot LUN discovery (F-BLD) pre-provisioning services allow servers to be quickly deployed, replaced, and moved across the SAN; the creation of zones, LUNs, and other services can be completed before the servers arrive on site.
-
Using the Brocade ClearLink diagnostic port (D_Port) available on the Brocade Gen 5 switches, administrators can quickly run automated diagnostic tests to assess the health of links and fabric components.
- Read diagnostic parameters (RDP) feature provides detailed port, media, and optics diagnostics to easily discover and diagnose link-related errors and degrading conditions on any N_Port-to-F_Port link.
- Link cable beacon (LCB) enables administrators to visually identify both ends of a physical link by flashing HBA's LEDs, simplifying identification of the connection peers within server racks without tracing the cable.
- Single-pane-of-glass management across generations of QLogic FC adapters with QLogic QConvergeConsole (QCC).
- Deployment flexibility and integration with third-party management tools, including the VMware® vCenter™ and Brocade Network Advisor.
- Support for 16 Gb, 8 Gb, and 4 Gb FC devices.
- Comprehensive virtualization capabilities with support for N_Port ID Virtualization (NPIV).
- A common driver model allows a single driver to support all QLogic HBAs on a given OS.
- Reduce the number of cards, cables, and PCIe slots required.
- Exceptional performance per watt and price/performance ratios.
- Backward compatibility with existing 4GFC and 8GFC infrastructure, leveraging existing SAN investments.
- Allow application of SAN best practices, tools, and processes with virtual server deployments.
- Ensure data availability and data integrity.
- Boot from SAN capability reduces the system management costs and increases uptime.
The following table compares features of QLogic Enhanced Gen 5 16 Gb, Gen 5 16 Gb, and 8 Gb FC HBAs.
Technical specifications
The QLogic Enhanced Gen 5 16 Gb FC HBAs have the following specifications:
- Based on the QLogic QLE2690 (single port) and QLE2692 (dual port) adapters
- Host interface: PCIe 3.0 x8
- Ports: Single-port and dual-port SFP+ based adapters
- Link speed: Support for 16 Gb, 8 Gb and 4 Gb FC link speeds, which are automatically negotiated
- Data rate: 14.025 Gbps (1600 MBps), 8.5 Gbps (800 MBps), and 4.25 Gbps (400 MBps) autosensing (per port), with full duplex
- Performance: Up to 1,300,000 IOPS (up to 650,000 IOPS per port)
- Fibre Channel standards: FC-PI-5, FC-GS-2, FC-GS-3, SCSI-FCP, FCP-2, FC-TAPE
- Topology: Point-to-point and switched fabric
- Hot-pluggable 16 Gbps Fibre Channel SFP+ short wave optical transceivers (850 nm) with LC connectors (included with the adapters). Note: Other transceivers are not supported.
- Distance support:
- Operating at 16 Gbps:
- Up to 35 m on 50/125 µm OM2 Multi-Mode Fiber (MMF)
- Up to 100 m on 50/125 µm OM3 MMF
-
Up to 125 m on 50/125 µm OM4 MMF
- Operating at 8 Gbps:
- Up to 21 m on 62.5/125 µm OM1 MMF
- Up to 50 m on 50/125 µm OM2 MMF
- Up to 150 m on 50/125 µm OM3 MMF
-
Up to 190 m on 50/125 µm OM4 MMF
- Operating at 4 Gbps:
- Up to 70 m on 62.5/125 µm OM1 MMF
- Up to 150 m on 50/125 µm OM2 MMF
- Up to 380 m on 50/125 µm OM3 MMF
-
Up to 400 m on 50/125 µm OM4 MMF
- Operating at 16 Gbps:
- Management software:
-
The QLogic unified management application, QLogic QConvergeConsole (QCC), provides single-pane-of-glass management across generations of QLogic FC adapters.
-
QLogic supports all major APIs for deployment flexibility and integration with third-party management tools, including the VMware vCenter and Brocade Network Advisor.
-
Server support - ThinkSystem
The following tables list the ThinkSystem servers that are compatible.
Server support - System x
The following tables list the System x servers that are compatible.
Support for System x and dense servers with Xeon E5/E7 v4 and E3 v5 processors
Support for System x and dense servers with Intel Xeon v3 processors
Operating system support
The adapter supports the following operating systems:
- QLogic 16Gb Enhanced Gen5 FC Single-port HBA, 01CV750
- QLogic 16Gb Enhanced Gen5 FC Dual-port HBA, 01CV760
Tip: These tables are automatically generated based on data from Lenovo ServerProven.
1 For limitation, please refer Support Tip 104278
2 The OS is not supported with EPYC 7003 processors.
1 Need out of box driver to support NPIV feature
1 Need out of box driver to support NPIV feature
2 Detail information please refer to Support Tip HT506708
3 [in box driver support only]
1 For limitation, please refer Support Tip 104278
2 The OS is not supported with EPYC 7003 processors.
1 Need out of box driver to support NPIV feature
1 Need out of box driver to support NPIV feature
2 The WWPN show wrong when created by excute FC-NPIV test under VM6.5.2 os.
3 [in box driver support only]
4 Detail information please refer to Support Tip HT506708
SAN switches
Lenovo offers the ThinkSystem DB Series of Fibre Channel SAN switches for high-performance storage expansion. See the DB Series product guides for models and configuration options:
- ThinkSystem DB Series SAN Switches:
https://lenovopress.com/storage/switches/rack#rt=product-guide
For information about interoperability with storage servers, see the Lenovo Storage Interoperability Links article, available from:
https://lenovopress.com/lp0584-lenovo-storage-interoperability-links
Warranty
The QLogic Enhanced Gen 5 16 Gb FC HBAs carry a one-year limited warranty. When installed in a supported server, the adapters assume the server's base warranty and any Lenovo Services warranty upgrade.
Physical specifications
The QLogic Enhanced Gen 5 16 Gb FC HBAs have the following dimensions (approximate):
- Low profile form factor card
- 168 mm x 69 mm (6.60 in. x 2.7 in.)
- Standard (3U) and low-profile (2U) brackets included
Operating environment
The QLogic Enhanced Gen 5 16 Gb FC HBAs are supported in the following environment:
- Temperature:
- Operating: 0 - 55 °C (32 - 131 °F)
- Storage: -20 - 70 °C (-4 - 185 °F)
- Relative humidity:
- Operating: 10 - 90% (non-condensing)
- Storage: 5 - 95% (non-condensing)
Agency approvals
The QLogic Enhanced Gen 5 16 Gb FC HBAs conform to the following regulations:
- AS/NZS CISPR22:2009+A1, Class A
- CSA 22.2, No. 60950-1-07 (2nd Edition)
- EN55022:2010, Class A
- EN55024:2010
- EU (CE Mark)
- FCC Rules, Part 15, Class A
- Industry Canada, ICES-003, Class A
- Japan VCCI, Class A
- Korea KC-RRA, Class A
- TUV EN60950-1:2006+A11+A1+A12 (2nd Edition)
- Taiwan BSMI, Class A
- UL60950-1 (2nd Edition)
Related publications and links
For more information, see the following resources:
-
Lenovo ThinkSystem network adapter summary
https://lenovopress.com/lp0765-networking-options-for-thinksystem-servers -
Lenovo server options product page
https://www.lenovo.com/us/en/data-center/options/ - Lenovo Storage Interoperability Links
https://lenovopress.com/lp0584-lenovo-storage-interoperability-links - Lenovo support
http://support.lenovo.com - Lenovo ServerProven
http://static.lenovo.com/us/en/serverproven/xseries/sharedstorage/samatrix.shtml
Trademarks
Lenovo and the Lenovo logo are trademarks or registered trademarks of Lenovo in the United States, other countries, or both. A current list of Lenovo trademarks is available on the Web at https://www.lenovo.com/us/en/legal/copytrade/.
The following terms are trademarks of Lenovo in the United States, other countries, or both:
Lenovo®
ServerProven®
System x®
ThinkSystem®
The following terms are trademarks of other companies:
AMD is a trademark of Advanced Micro Devices, Inc.
Intel® and Xeon® are trademarks of Intel Corporation or its subsidiaries.
Linux® is the trademark of Linus Torvalds in the U.S. and other countries.
Microsoft®, Windows Server®, and Windows® are trademarks of Microsoft Corporation in the United States, other countries, or both.
Other company, product, or service names may be trademarks or service marks of others.
Configure and Buy
Full Change History
Changes in the February 18, 2021 update:
- The adapter supports the FC-NVMe (NVMe over Fibre Channel) protocol - Key features section
- The server support tables are now automatically updated - Server support section
Changes in the October 13, 2020 update:
- Added the SR850 V2 and SR860 V2 servers - Server support section
Changes in the May 5, 2020 update:
- Added SR645 and SR665 to the server support table - Server support section
Changes in the January 7, 2020 update:
- Added SR850P to the server support table - Server support section
Changes in the September 25, 2019 update:
- Added SE350, SR635 and SR655 to the Server support table
- Operating system support information is now listed as tables which are automatically generated from ServerProven data - Operating system support section
Changes in the November 28, 2017 update:
- Updated the ThinkSystem server support table
- Added a table of fiber optic cables that are available from Lenovo
Changes in the October 29, 2017 update:
- Add the vendor adapter name - Technical specifications section
First published: 14 June 2016
Course Detail
Employees Only Content
The content in this document with a is only visible to employees who are logged in. Logon using your Lenovo ITcode and password via Lenovo single-signon (SSO).
The author of the document has determined that this content is classified as Lenovo Internal and should not be normally be made available to people who are not employees or contractors. This includes partners, customers, and competitors. The reasons may vary and you should reach out to the authors of the document for clarification, if needed. Be cautious about sharing this content with others as it may contain sensitive information.
Any visitor to the Lenovo Press web site who is not logged on will not be able to see this employee-only content. This content is excluded from search engine indexes and will not appear in any search results.
For all users, including logged-in employees, this employee-only content does not appear in the PDF version of this document.
This functionality is cookie based. The web site will normally remember your login state between browser sessions, however, if you clear cookies at the end of a session or work in an Incognito/Private browser window, then you will need to log in each time.
If you have any questions about this feature of the Lenovo Press web, please email David Watts at dwatts@lenovo.com.