skip to main content

Lenovo ThinkSystem DB400D and DB800D 32Gb FC SAN Directors

Product Guide (withdrawn product)

Home
Top

Abstract

The Lenovo ThinkSystem DB400D and DB800D 32Gb FC SAN Directors combine innovative hardware, software, and integrated network sensors to ensure the highest levels of operational stability and application performance. Designed to enable maximum flexibility and reliability, the Lenovo FC SAN directors deliver market-leading 32 Gb Gen 6 Fibre Channel technology with modular building blocks for increased scalability to accommodate growth for large-scale enterprise infrastructures.

This product guide provides essential pre-sales information to understand the DB400D and DB800D 32Gb FC SAN Directors, their key features and specifications, components and options, and configuration guidelines.

This guide is intended for technical specialists, sales specialists, sales engineers, IT architects, and other IT professionals who want to learn more about the DB400D and DB800D 32Gb FC SAN Directors and consider their use in IT solutions.

Change History

Changes in the August 12, 2021

  • All ThinkSystem DB400D and DB800D models are now withdrawn from marketing

Introduction

The Lenovo ThinkSystem DB400D and DB800D 32Gb FC SAN Directors combine innovative hardware, firmware, and integrated network sensors to ensure the highest levels of operational stability and application performance. Designed to enable maximum flexibility and reliability, the Lenovo FC SAN Directors deliver market-leading 32 Gb Gen 6 Fibre Channel technology with modular building blocks for increased scalability to accommodate growth for large-scale enterprise infrastructures.

The Lenovo FC SAN Directors provide full non-blocking performance with scalability of up to four (DB400D) or eight (DB800D) port blades to deliver up to 256x (DB400D) or 512x (DB800D) ports that are FC-capable with speeds up to 32 Gbps or FCoE-capable of speeds up to 25 Gbps. The Directors also offer FCoE support with up to 64x (DB400D) or 128x (DB800D) 40 Gbps FCoE ports.

The Lenovo FC SAN Directors offer FC over IP extension capabilities with support for up to 8x 40 GbE QSFP+ ports and up to 64x 1/10 GbE SFP+ ports with up to four extension blades. For inter-chassis connectivity, the Directors provide 16x (DB400D) or 32x (DB800D) FC QSFP+ ports that support 4x 16/32 Gbps speeds.

Lenovo ThinkSystem DB400D (Left) and DB800D (Right) 32Gb FC SAN Directors
Figure 1. Lenovo ThinkSystem DB400D (Left) and DB800D (Right) 32Gb FC SAN Directors

Did you know?

The DB400D and DB800D 32Gb FC SAN Directors leverage storage connectivity technologies from Brocade, a leader in Fibre Channel networking.

Fabric Vision technology, an extension of Gen 6 Fibre Channel, provides unprecedented insight and visibility across the SAN with powerful built-in monitoring, management, and diagnostic tools.

With Lenovo FC SAN Switch offerings, Lenovo can be your trusted partner that offers "one stop shop" and single point of contact for delivery of leading-edge technologies and innovations from Lenovo and other leading IT vendors. These offerings can satisfy the wide range of your end-to-end IT infrastructure needs, including end-user devices, servers, storage, networking, services, management software, and financing.

Key features

The ThinkSystem DB400D and DB800D 32Gb FC SAN Directors offer the following features and benefits:

  • Enhance operational stability, maximize application performance, and increase business agility with enterprise-class Gen 6 FC SAN directors
  • Scale to 256 (DB400D) or 512 (DB800D) FC or FCoE ports with industry-leading port density and consolidate infrastructure with 128 Gbps Brocade UltraScale ICL connectivity for simpler, flatter, low-latency fabrics.
  • Enable “pay-as-you-grow” scalability with full-fabric enterprise capabilities, supporting Fibre Channel connectivity of up to 32 Gbps or Fibre Channel over Ethernet (FCoE) connectivity of up to 40 Gbps.
  • Accelerate application response time by up to 71 percent across 32 Gbps FC links.
  • Optimize fabric behavior and ensure sufficient bandwidth for mission-critical applications with advanced traffic management capabilities and adaptive networking.
  • Extend replication over distance with a highly scalable extension solution for Fibre Channel, IP, and FICON.
  • Protect existing device investments with auto-sensing 4, 8, 16, and 32 Gbit/sec capabilities and native operation with Fabric OS-based fabrics.
  • Simplify end-to-end management of large-scale environments by automating monitoring and diagnostics.
  • Run Fabric OS, which delivers distributed intelligence throughout the network and enables a wide range of value-added features.
  • Leverage Fabric Vision technology’s powerful monitoring, management, and diagnostic tools to simplify administration, increase uptime, and reduce costs.
  • Provide proactive, non-intrusive, real-time monitoring and alerting of VM and storage I/O health and performance with VM Insight and IO Insight through integrated network sensors.
  • Leverage predefined MAPS policies to automatically identify and isolate devices that cause network performance issues.
  • Supply a rich set of standard features at no extra cost, including fabric services, advanced zoning, adaptive networking, integrated 10 Gb FC, diagnostic tools, ISL trunking, advanced monitoring and alerting, long-distance fabrics, and FICON CUP.
  • Expand fabric capabilities with optional licensed functions, including Inter-Chassis Links (ICLs) and FC-FC routing.
  • Compress and encrypt in-flight data on up to four ports for more efficient link utilization and better security.
  • Virtualize physical FC SAN switches and fabrics into logical entities for better flexibility, utilization, management, and efficiency.
  • Allow organizations to seamlessly integrate Gen 6 Fibre Channel networks with the next generation of flash storage – NVMe over Fibre Channel – by being NVMe-ready, without a disruptive rip and replace, to achieve faster application response times and harness the performance of solid state drives for better scalability across virtual data centers with flash storage.
  • Help optimize the performance of NVMe with real-time latency monitoring on the FC32-64 port blade.
  • Designed to provide 99.999% uptime capabilities and maximize resiliency with redundant hot-swap components, including power supplies, cooling modules, blades, transceivers, online diagnostics, and non-disruptive firmware download and activation.
  • Accelerate troubleshooting with built-in advanced diagnostics tools featuring ClearLink Diagnostics with D_Ports and select adapters from QLogic and Emulex, which helps ensure optical and signal integrity for 16 Gb and 32 Gb Fibre Channel optics and cables.
  • Automate repetitive daily tasks (such as fabric inventory, provisioning, and operational state monitoring) by using the standard REST APIs available directly from the switch.
  • Simplify common SAN management practices by quickly integrating systems with open source PyFOS, a Python language.

Components and connectors

The following figure shows the port-side view of the DB400D 32Gb FC SAN Director.

DB400D 32Gb FC SAN Director port-side view
Figure 2. DB400D 32Gb FC SAN Director port-side view

The port side of the DB400D chassis has the following components:

  • Two redundant hot-swap active/standby Control Processor blades (CP blades come with the chassis)

    A Control Processor (CP) blade contains the control plane for the device and hosts the Fabric OS that manages all hardware within the device, and it provides the following external connections for device configuration, firmware downloads, service, management, and monitoring functions:

    • USB port for firmware download and technical support data
    • Serial console RJ-45 port
    • 10/100/1000 Mb Ethernet RJ-45 port for device management and configuration
    • 10/100/1000 Mb Ethernet RJ-45 port for service
    • 10 Gb Ethernet RJ-45 port (reserved for future use)

    Note: The two 10/100/1000 Mb Ethernet ports are configured in an active/standby pair.

  • Two redundant hot-swap active/active Core Routing CR32-4 blades (CR blades come with the chassis)

    Core routing blades contain ASICs that allow switching between up to four port blades, and each core routing blade provides 96 Fibre Channel backplane ports for port or extension blade connections and 32 front-end FC links that are mapped to 8 QSFP+ ports for inter-chassis links (ICLs).

  • Four hot-swap slots for port blades and extension blades (The chassis comes without port blades or extension blades, see Blades for ordering information)

The following figure shows the non-port side view of the DB400D 32Gb FC SAN Director.

DB400D 32Gb FC SAN Director non-port side view
Figure 3. DB400D 32Gb FC SAN Director non-port side view

The non-port side of the DB400D chassis has the following components:

  • Two hot-swap power supplies (must be ordered together with the chassis)
  • Two hot-swap cooling modules (must be ordered together with the chassis)

The following figure shows the port-side view of the DB800D 32Gb FC SAN Director.

DB800D 32Gb FC SAN Director port-side view
Figure 4. DB800D 32Gb FC SAN Director port-side view

The port side of the DB800D chassis has the following components:

  • Two redundant hot-swap active/standby Control Processor blades (CP blades come with the chassis)

    A Control Processor (CP) blade contains the control plane for the device and hosts the Fabric OS that manages all hardware within the device, and it provides the following external connections for device configuration, firmware downloads, service, management, and monitoring functions:

    • USB port for firmware download and technical support data
    • Serial console RJ-45 port
    • 10/100/1000 Mb Ethernet RJ-45 port for device management and configuration
    • 10/100/1000 Mb Ethernet RJ-45 port for service
    • 10 Gb Ethernet RJ-45 port (reserved for future use)
    Note: The two 10/100/1000 Mb Ethernet ports are configured in an active/standby pair.
  • Two redundant hot-swap active/active Core Routing CR32-8 blades (CR blades come with the chassis)

    Core routing blades contain ASICs that allow switching between up to eight port blades, and each core routing blade provides 192 Fibre Channel backplane ports for port or extension blade connections and 64 front-end FC links that are mapped to 16 QSFP+ ports for inter-chassis links (ICLs).

  • Eight hot-swap slots for port blades and extension blades (The chassis comes without port blades or extension blades, see Blades for ordering information)

The following figure shows the non-port side view of the DB800D 32Gb FC SAN Director.

DB800D 32Gb FC SAN Director non-port side view
Figure 5. DB800D 32Gb FC SAN Director non-port side view

The non-port side of the DB800D chassis has the following components:

  • Three or four hot-swap power supplies (must be ordered together with the chassis)
  • Three hot-swap cooling modules (must be ordered together with the chassis)

The following figure shows the FC32-64 port blade.

FC32-64 port blade
Figure 6. FC32-64 port blade

The FC32-64 port blade contains 16 QSFP+/QSFP28 ports can be split out into four Fibre Channel ports capable of speeds up to 32 Gbps or four FCoE ports capable of 10 Gbps or 25 Gbps speeds. Each QSFP+ port is also capable of supporting 40 Gbps FCoE. The FC32-64 port blade enables industry-leading platform density for Gen 6 SAN configurations supporting up to 256 32-Gbps external ports in a single DB400D chassis, and up to 512 32-Gbps external ports in a single DB800D chassis.

The following figure shows the FC32-48 port blade.

FC32-48 port blade
Figure 7. FC32-48 port blade

The FC32-48 port blade contains 48 ports capable of Fibre Channel speeds up to 32 Gbps. The FC32-48 port blade enables Gen 6 SAN configurations supporting up to 192 32-Gbps external ports in a single DB400D chassis, and up to 384 32-Gbps external ports in a single DB800D chassis.

The following figure shows the SX6 extension blade.

SX6 extension blade
Figure 8. SX6 extension blade

The SX6 Extension blade is intended as an extension platform to support Fibre Channel, FICON, and IP based storage data flows. Extension features enable you to use the existing IP wide area network (WAN) infrastructure to connect Fibre Channel and IP fabrics. Extension features support applications such as remote data replication (RDR), centralized backup, and data migration over very long distances. Extension tunnels, built on a physical connection between two extension switches or blades, allow Fibre Channel and IP I/O to pass through the IP WAN. The SX6 Extension blade can connect with an SX6 blade in another DB400D or DB800D 32Gb FC SAN Director or with a Brocade 7840 Extension Switch.

System specifications

The following table lists the ThinkSystem DB400D and DB800D 32Gb FC SAN Director system specifications.

Note: The supported hardware options and firmware features listed in this product guide are based on the Fabric OS version 8.2. For details about specific firmware releases that introduced support for certain hardware options and firmware features, refer to the Release notes of the particular firmware release that can be found at:
http://datacentersupport.lenovo.com/us/en/products/storage/fibre-channel-switches/db400d-fc-switch/6682/downloads
http://datacentersupport.lenovo.com/us/en/products/storage/fibre-channel-switches/db800d-fc-switch/6684/downloads

Table 1. ThinkSystem DB400D and DB800D 32Gb FC SAN Director system specifications
Attribute Specification
DB400D DB800D
Machine type 6684 6682
Form factor 8U rack mount
9U rack mount with the airflow diversion kit
14U rack mount
Blades
  • 2x Redundant control processor blades
  • 2x Redundant CR32-4 core routing blades
  • 4x slots for port and extension blades:
    • Up to 4x FC32-64 port blades
    • Up to 4x FC32-48 port blades
    • Up to 4x SX6 extension blades
  • 2x Redundant Control processor blades
  • 2x Redundant CR32-8 core routing blades
  • 8x slots for port and extension blades:
    • Up to 8x FC32-64 port blades
    • Up to 8x FC32-48 port blades
    • Up to 4x SX6 extension blades
Ports
  • CR32-4 core routing blade:
    • 8x 64/128 Gb FC QSFP+ ports
  • CR32-8 core routing blade:
    • 16x 64/128 Gb FC QSFP+ ports
  • FC32-64 port blade:
    • 16x QSFP+/QSFP28 ports; each port is capable of:
      • 4x 4/8/16/32 Gb FC; or
      • 4x 10 Gb or 4x 25 Gb FCoE; or
      • 1x 40 Gb FCoE
  • FC32-48 port blade:
    • 48x 4/8/10/16/32 Gb FC SFP+ ports
  • SX6 extension blade:
    • 16x 4/8/10/16/32 Gb FC SFP+ ports
    • 16x 1/10 Gb Ethernet SFP+ ports
    • 2x 40 Gb Ethernet QSFP+ ports
Media types
  • Fibre Channel transceivers:
    • 128 Gb (4x 32 Gb, supports 16/32Gb/s) FC QSFP+: short-wavelength (SWL), long-wavelength (LWL).
    • 4x 16 Gb (supports 4/8/16 Gb/s) FC QSFP+: SWL, LWL.
    • 32 Gb FC SFP+: SWL, LWL.
    • 16 Gb FC SFP+: SWL, LWL, extended long-wavelength (ELWL).
    • 10 Gb FC SFP+: SWL, LWL.
  • Fibre Channel over Ethernet (FCoE) transceivers:
    • 100 Gb (4x 25 Gb) FCoE QSFP28: SWL.
    • 40 Gb (4x 10 Gb) FCoE QSFP+: SWL.
    • 40 Gb BiDi FCoE QSFP+: SWL.
  • Ethernet transceivers:
    • 40 GbE QSFP+: short-range (SR4), long-range (LR4), extended range (ER4).
    • 10 GbE SFP+: short-range (SR), long-range (LR), Dense Wavelength Division Multiplexing (DWDM).
    • 1 GbE SFP: short-wavelength (SX), long-wavelength (LX), RJ-45 unshielded twisted pair (UTP).
Port speeds
  • Fibre Channel transceivers:
    • 128 Gb (4x 32 Gb) FC SWL QSFP+: 4x 32 Gbps or 4x 16 Gbps.
    • 128 Gb (4x 32 Gb) FC LWL QSFP+: 4x 32 Gbps fixed.
    • 4x 16 Gb FC QSFP+: 4x 16 Gbps fixed.
    • 32 Gb FC SFP+: 32/16/8 Gbps auto-sensing.
    • 16 Gb FC SFP+: 16/8/4 Gbps auto-sensing.
    • 10 Gb FC SFP+: 10 Gbps fixed.
  • Fibre Channel over Ethernet (FCoE) transceivers:
    • 100 Gb (4x 25 Gb) FCoE QSFP28: 4x 25 Gbps fixed.
    • 40 Gb (4x 10 Gb) FCoE QSFP+: 40 Gbps or 4x 10 Gbps.
    • 40 Gb BiDi FCoE QSFP+: 40 Gbps fixed.
  • Ethernet transceivers:
    • 40 GbE QSFP+: 40 Gbps fixed
    • 10 GbE SFP+: 10 Gbps fixed
    • 1 GbE SFP: 1 Gbps fixed
FC port types
  • FC32-64 port blade:
    • F_Port, E_Port, VF_Port (FCoE), VE_Port (FCoE), EX_Port (Requires an optional Integrated Routing License), M_Port (Mirror Port), D_Port (Diagnostic Port).
  • FC32-48 port blade:
    • F_Port, E_Port, EX_Port (Requires an optional Integrated Routing License), M_Port (Mirror Port), D_Port (Diagnostic Port).
  • SX6 extension blade:
    • F_Port, FL_Port, E_Port, EX_Port (FC), VE_Port (Ethernet) (EX_Port and VE_Port require an optional Integrated Routing License).
  • Core routing blades (CR32-4 and CR32-8):
    • E_Port, EX_Port (EX_Port requires an optional Integrated Routing License).
Data traffic types Unicast (Class 2 and Class 3), multicast (Class 3 only), broadcast (Class 3 only).
Classes of service Class 2, Class 3, Class F (inter-switch frames).
Standard features Full Fabric, Advanced Zoning, Fabric Services, 10 Gb FC, Adaptive Networking, Advanced Diagnostic Tools, Virtual Fabrics, In-flight Compression, In-flight Encryption, ISL Trunking, Fabric Vision, Extended Fabric, FICON CUP (except FC32-64 port blade).
Optional features UltraScale Inter-Chassis Links (ICLs), Integrated Routing.
Architecture Non-blocking shared memory; passive backplane; redundant active/passive control processor; redundant active/active core switching blades; redundant WWN cards.
Performance
  • Slot bandwidth: 1.536 Tbps
    • FC32-48 port blade, SX6 extension blade: Line-rate performance
    • FC32-64 port blade: 1.33 to 1 oversubscription
  • Line-rate forwarding of FC traffic:
    • 4GFC: 4.25 Gbit/sec line speed, full duplex
    • 8GFC: 8.5 Gbit/sec line speed, full duplex
    • 10GFC: 10.51875 Gbit/sec line speed, full duplex
    • 16GFC: 14.025 Gbit/sec line speed, full duplex
    • 32GFC: 28.05 Gbit/sec line speed, full duplex
  • Cut-through FC switching:
    • Up to 780 ns port-to-port local switching latency (including FEC)
    • Up to 2.6 µs blade-to-blade switching latency (including FEC)
Aggregated throughput 10.24 Tbps 20.48 Tbps
Scalability
  • Maximum number of switches in the fabric: 239
  • Maximum frame size: 2,112-byte payload
  • Maximum number of frame buffers per switching ASIC: 15,360
  • Maximum number of ports per ISL trunk: 8x SFP+
  • Maximum bandwidth per ISL trunk: 256 Gbps
  • Maximum number of ports per UltraScale ICL trunk (CR blades only): 4x QSFP+
  • Maximum bandwidth per UltraScale ICL trunk (CR blades only): 512 Gbps
  • Maximum UltraScale ICL bandwidth per chassis (CR blades only):
    • DB400D: 2.048 Tbps
    • DB800D: 4.096 Tbps
  • Maximum number of chassis in UltraScale ICL multi-chassis configurations:
    • Full mesh topology: 9
    • Core-edge topology: 12
  • Maximum number of ports in UltraScale ICL multi-chassis configurations:
    • Full mesh topology: 4,608
    • Core-edge topology: 6,144
Cooling 2x Hot-swap cooling modules required; each module contains two fans. N+1 (3+1) fan redundancy. Non-port side to side vent (default) or non-port to port side (optional) airflow. 3x Hot-swap cooling modules required; each module contains two fans. N+1 (5+1) fan redundancy. Non-port to port side airflow.
Power supply type 1450 W (100 - 120 V AC) / 2870 W (200 - 240 V AC) hot-swap power supply (IEC 309-C20 connector).
Power supply quantity 2 required 3 required; 4 maximum
Hot-swap parts Blades, SFP+/QSFP+ transceivers, power supplies, cooling modules.
Management ports Per control processor blade:
  • 2x 10/100/1000 Mb Ethernet ports (UTP, RJ-45); 1x RS-232 port (RJ-45); 1x USB port (for additional firmware/log/configuration files storage; requires a supported USB memory key).
In-band management over Fibre Channel is supported.
Management interfaces Web-based GUI (Web Tools); Command Line Interface (CLI); SMI-S; SNMP; REST API. Optional Brocade SANnav Management Portal and SANnav Global View, or Brocade Network Advisor.
Security features Secure Socket Layer (SSL); Secure Shell (SSH); Secure Copy (SCP); Secure FTP (SFTP); user level security, Role-based Access Control (RBAC); LDAP, RADIUS, and TACACS+ authentication; access control lists (ACLs)
Hardware warranty One-year customer-replaceable unit limited warranty with 9x5 next business day parts delivered. 
Service and support Optional service upgrades are available through Lenovo Services: 9x5 next business day onsite response, 24x7 2-hour or 4-hour onsite response, 24x7 6-hour or 24-hour committed service repair, up to 5 years of warranty coverage, and 1-year or 2-year post-warranty extensions.
Firmware entitlement One-year (DB400D and DB800D Models HC2) or three-year (DB400D and DB800D Models HC1) firmware entitlement and support license is included. Optional one- and two-year firmware support extension licenses are available from Lenovo for DB400D and DB800D Models HC1. Firmware entitlement extension licenses for DB400D and DB800D Models HC2 are included in the warranty service upgrades for DB400D and DB800D Models HC2.
Dimensions
  • Height: 345 mm (13.6 in.)
  • Width: 437 mm (17.2 in.)
  • Depth: 611 mm (24.0 in.) 
  • Height: 612 mm (24.1 in.)
  • Width: 437 mm (17.2 in.)
  • Depth: 611 mm (24.0 in.)
Weight
  • Empty: 24.5 kg (54.0 lb)
  • Fully configured: 69.0 kg (152.0 lb).
  • Empty: 35.6 kg (78.5 lb)
  • Fully configured: 145.8 kg (321.5 lb).

Models

The following table lists the DB400D and DB800D 32Gb FC SAN Director models.

Withdrawn: All models are now withdrawn from marketing

Table 2. DB400D and DB800D 32Gb FC SAN Director models
Description Part number Machine
Type-Model
Feature code
Lenovo ThinkSystem DB400D 32Gb FC Director, ENT. Feature set, 4 Blade slots, 8U, 1Yr FW 6684D2A 6684HC2 B4QH
Lenovo ThinkSystem DB400D 32Gb FC Director, ENT. Feature set, 4 Blade slots, 8U, 3Yr FW 6684B2A 6684HC1 AVK7
Lenovo ThinkSystem DB800D 32Gb FC Director, ENT. Feature set, 8 Blade slots, 14U, 1Yr FW 6682D1A 6682HC2 B4QG
Lenovo ThinkSystem DB800D 32Gb FC Director, ENT. Feature set, 8 Blade slots, 14U, 3Yr FW 6682B1A 6682HC1 AVGJ

The DB400D and DB800D 32Gb FC SAN Director part numbers include the following items:

  • One 32 Gb FC Director chassis that contains the following components:
    • Two control blades
    • Two core routing blades
  • Chassis door
  • Serial cable (DB-9/RJ-45 to RJ-45)
  • Power cord retainer clips
  • Cable management assembly
  • Adjustable rack mount kit
  • Ground lug kit
  • Online Documentation web pointer card
  • SANNav web pointer card

Configuration notes:

  • The ThinkSystem DB400D and DB800D models come standard without port or extension blades; they should be ordered for the director model (See Blades for details).
  • The ThinkSystem DB400D and DB800D models come standard without fan modules and power supplies; at least a minimum quantity required must be ordered together with the director model (See Cooling and Power supplies and cables for details).
  • The ThinkSystem DB400D and DB800D models come standard without power cords; they must be ordered together with the director model (see Power supplies and cables for details).

Blades

The DB400D and DB800D 32Gb FC SAN Directors support the port and extension blade options that are listed in the following table.

Table 3. Port and extension blades
Description Part number Feature code Quantity
DB400D DB800D
Port blades (for Models HC1 and HC2)
Lenovo Gen 6 Port Blade FC32-48 (no transceivers) 01KN845 AVGT 4 8
Lenovo Gen 6 Port Blade FC32-48 (48 transceivers, 32Gbps) 01KN848 AVGU 4 8
Lenovo Gen 6 Port Blade FC32-64 (8 4x32Gb QSFP+ transceivers) 4M27A09985 B26X 4 8
Extension blades (for Model HC1)
Lenovo SX6 FC-IP SAN Extension Blade + 16 32Gb SWL SFPs 01KN850 AVGV 4 4
Lenovo SX6 FC-IP SAN Extension Blade + 16 32Gb LWL SFPs 01KN854 AVGW 4 4
Extension blades (for Model HC2)
Lenovo SX6 FC-IP SAN Extension Blade + 16 32Gb SWL SFPs, 1YR 4M27A14145 B5Z7 4 4
Lenovo SX6 FC-IP SAN Extension Blade + 16 32Gb LWL SFPs, 1YR 4M27A14146 B5Z8 4 4

Port and extension blades come standard with all ports activated, and certain part numbers also include transceivers. Additional transceivers and cables can be ordered, if required (See Transceivers and cables for details).

Transceivers and cables

With the flexibility of the DB400D and DB800D 32Gb FC SAN Directors, customers can choose the following connectivity technologies:

  • SFP+ ports on the FC32-48 port blade and SX6 extension blade
    • For 32 Gb FC links, customers can use 32 Gb FC SFP+ SW optical transceivers for distances up to 100 meters on OM4 or up to 70 meters on OM3 50 µ multimode fiber (MMF) optic cables. For longer distances, the 32 Gb FC LW SFP+ optical transceivers can support up to 10 kilometers on 9 µ single-mode fiber (SMF) optic cables.
    • For 16 Gb FC links, customers can use 16 Gb FC SFP+ SW optical transceivers for distances up to 125 meters on OM4 or up to 100 meters on OM3 50 µ MMF cables. For longer distances, the 16 Gb FC LW SFP+ optical transceivers can support up to 10 kilometers on 9 µ SMF cables. For extended distances, the 16 Gb FC ELW SFP+ optical transceivers can support up to 25 kilometers on 9 µ SMF cables.
    • For 10 Gb FC links, customers can use 10 Gb FC SFP+ SW transceivers for distances up to 550 meters on OM4 or up to 300 meters on OM3 50 µ MMF cables, or 10 Gb FC SFP+ LW transceivers for distances up to 10 km on 9 µ SMF cables. 10 Gb FC operations allow metro connectivity by directly utilizing a fiber optic cable between sites or by creating multiple channels on an optical cable between sites, utilizing Wave Division Multiplexing (WDM) technology.
  • QSFP+/QSFP28 ports on the FC32-64 port blade
    • For 32 Gb FC links, customers can use the 128 Gb (4x 32 Gbps) SWL QSFP+ Transceiver with OM4 MMF MPO-4xLC breakout cables for distances up to 100 meters or OM3 MMF MPO-4xLC breakout cables for distances up to 70 meters. For longer-distance ISL links, the 128 Gb (4x 32 Gbps) FC LWL QSFP+ optical transceivers can support up to 2 kilometers on 9 µ SMF cables.
    • For 16 Gb FC links, customers can use MMF MPO-4xLC breakout cables with the following transceivers:
      • 128 Gb (4x 32 Gb) QSFP+ SWL optical transceivers running at 4x 16 Gb speeds for distances up to 125 meters on OM4 or up to 100 meters on OM3 MMF cables.
      • 4x 16 Gb FC QSFP+ SWL optical transceivers for distances up to 100 meters on OM4 or up to 66 meters on OM3 MMF cables.
    • For 40 Gb FCoE links, customers can use the 40 Gb SR4 QSFP+ bi-directional transceivers or 40 Gb (4x 10 Gbps) SR4 QSFP+ transceivers for distances up to 100 meters on OM3 or up to 150 meters on OM4 MMF cables.
    • For 25 Gb FCoE links, customers can use the 100 Gb (4x 25 Gbps) QSFP28 SR4 transceiver for distances up to 70 meters on OM3 or up to 100 meters on OM4 MMF MPO-4xLC breakout cables.
    • For 10 Gb FCoE links, customers can use the 40 Gb (4x 10 Gbps) SR4 QSFP+ transceivers for distances up to 100 meters on OM3 or up to 150 meters on OM4 MMF MPO-4xLC breakout cables.
  • QSFP+ ports on the core routing blades:
    • For 128 Gb FC inter-chassis links for connectivity between the DB400D or DB800D 32Gb FC Directors, customers can use 128 Gb (4x 32 Gb) FC QSFP+ SW optical transceivers for distances up to 100 meters on OM4 or up to 70 meters on OM3 50 µ MMF cables.
      Note: ICL trunks are formed automatically with corresponding 32 Gbps ports on different QSFP+ transceivers (ICL trunks cannot be formed with the 4x 32 Gbps ports on the same QSFP+ transceiver), and the trunking license is not required.
    • For 64 Gb FC inter-chassis links for connectivity between the DB400D or DB800D 32Gb FC Directors and Brocade DCX 8510 Backbones, customers can use the following transceivers:
      • 128 Gb (4x 32 Gb) QSFP+ SWL v2 optical transceivers running at 4x 16 Gb speeds for distances up to 125 meters on OM4 or up to 100 meters on OM3 50 µ MMF cables.
      • 4x 16 Gb FC QSFP+ SWL optical transceivers for distances up to 100 meters on OM4 or up to 66 meters on OM3 50 µ MMF cables.
      • 4x 16 Gb FC QSFP+ LWL optical transceivers for distances up to 2 kilometers on parallel 9 µ SMF cables.
      Note: ICL trunks are formed automatically with corresponding 16 Gbps ports on different QSFP+ transceivers (ICL trunks cannot be formed with the 4x 16 Gbps ports on the same QSFP+ transceiver), and the trunking license is not required.
  • 1/10 GbE SFP+ and 40 GbE QSFP+ ports on extension blades allow connection to IP WANs and allow Fibre Channel and IP I/O traffic to pass through the IP WAN through extension tunnels.
    • For 1 GbE links, customers can use RJ-45 SFP transceivers with UTP cables up to 100 meters. Customers that need longer distances can use a 1000BASE-SX transceiver, which can drive distances up to 220 meters with 62.5 µ OM1 and up to 550 meters on 50 µ OM2 MMF cables, or the 1000BASE-LX transceivers that support distances up to 10 kilometers on 9 µ SMF cables.
    • For 10 GbE links, customers can use a 10GBASE-SR transceiver that supports distances up to 300 meters on OM3 or up to 400 meters on OM4 50 µ MMF cables. For longer distances, the 10GBASE-LR transceivers can support distances up to 10 kilometers on 9 µ SMF cables.

      For distances up to 80 km, customers can use the 10GBASE-ZRD Tunable DWDM optical transceiver on 9 µ SMF cables.

    • For 40 GbE links, customers can use the 40GBASE-SR4 QSFP+ transceivers for distances up to 100 meters on OM3 or up to 150 meters on OM4 50 µ MMF cables. For longer distances, the 40GBASE-LR4 transceivers can support distances up to 10 kilometers on 9 µ SMF cables. For extended distances, the 40GBASE-ER4 transceivers can support distances up to 40 kilometers on 9 µ SMF cables.

  • 1 GbE RJ-45 management ports on control processor blades: Customers can use UTP cables for distances up to 100 meters.

The FC32-64 port blades come standard with 8x 128 Gb (4x 32 Gbps) SWL QSFP+ transceivers. The FC32-48 port blades come standard with or without 48x 32 Gb FC SWL SFP+ transceivers. The SX6 extension blades come standard with 16x 32 Gb FC SWL or LWL SFP+ transceivers. The optional ICL bundles include 8x or 16x 128 Gb FC or 64 Gb FC QSFP+ transceivers. Additional Fibre Channel or Ethernet SFP+ and QSFP+/QSFP28 transceivers can be ordered, if required.

The following table lists the supported SFP+ and QSFP+/QSFP28 transceiver options and optical cables.

Brocade secure transceivers: These new transceivers have features to ensure that you are using genuine Brocade components to maximize performance and reliability and to help avoid issues related to counterfeit products.

Table 4. SFP+ and QSFP+/QSFP28 transceivers and optical cables
Description Part number Feature code Maximum quantity supported
Per blade Per chassis
FC32-48
FC32-64
SX6
CR32-4
CR32-8
DB400D
DB800D
QSFP+ FC transceivers
Brocade Secure 128Gb (4x 32Gb) SWL QSFP+ 4M27A65422 BF6G - 16 - 8 16 80 160
Brocade 128Gb (4x32Gbps) SWL QSFP+ Transceiver v2 4M27A08820 B145 - 16 - 8 16 80 160
Brocade 128Gb (4x32Gbps) 2KM QSFP+ Transceiver 4M27A09986 B26T - 16 - 8 16 80 160
Brocade 4x16Gb FC-Compliant SWL QSFP+ Transceiver 01KN805 AVGH - 16 - 8 16 80 160
Brocade 4x16Gbps 2km LWL QSFP+ Transceiver 01KN809 AVGK - - - 8 16 16 32
QSFP+/QSFP28 FCoE transceivers
Brocade 100Gb (4x25GbE) QSFP28 SR4 FCoE Transceiver 4M27A09989 B26W - 16 - - - 64 128
Brocade 40Gb (4x10GbE) QSFP+ SR4 FCoE Transceiver 4M27A09987 B26U - 16 - - - 64 128
Brocade 40Gb QSFP+ SR4 FCoE Transceiver, BiDi 4M27A09988 B26V - 16 - - - 64 128
32 Gb FC SFP+ transceivers 
Brocade Secure 32Gb SWL SFP+ Transceiver 4M27A65416 BF69 48 - 16 - - 192 384
Brocade Secure 32Gb SWL SFP+ Transceiver (8-pack) 4M27A65417 BF6A 6 - 2 - - 24 48
Brocade Secure 32Gb LWL SFP+ Transceiver 4M27A65418 BF6B 48 - 16 - - 192 384
Brocade Secure 32Gb LWL SFP+ Transceiver (8-pack) 4M27A65419 BF6C 6 - 2 - - 24 48
Brocade Secure 32Gb ELWL SFP+ (25 km) 4M27A65424 BF6D 48 - 16 - - 192 384
Brocade 32Gb SWL SFP+ Transceiver 01KN789 AVGC 48 - 16 - - 192 384
Brocade 32Gb SWL SFP+ Transceiver (8-pack) 01KN793 AVGD 6 - 2 - - 24 48
Brocade 32Gb LWL SFP+ Transceiver 01KN795 AVGE 48 - 16 - - 192 384
Brocade 32Gb LWL SFP+ Transceiver (8-pack) 01KN799 AVGF 6 - 2 - - 24 48
16 Gb FC SFP+ transceivers
Brocade Secure 16Gb SWL SFP+ 4M27A65411 BF64 48 - 16 - - 192 384
Brocade Secure 16Gb SWL SFP+ 8-pack 4M27A65412 BF65 6 - 2 - - 24 48
Brocade Secure 16Gb LWL SFP+ (10 km) 4M27A65413 BF66 48 - 16 - - 192 384
Brocade Secure 16Gb LWL SFP+ (10 km) 8pk 4M27A65414 BF67 6 - 2 - - 24 48
Brocade Secure 16Gb ELWL SFP+ (25 km) 4M27A65415 BF68 48 - 16 - - 192 384
Brocade 16Gb SWL SFP+ Optical Transceiver 88Y6393 A22R 48 - 16 - - 192 384
Brocade 16Gb 10km LWL SFP+ Transceiver 00MY768 ASK2 48 - 16 - - 192 384
Brocade 16Gb 25km ELWL SFP+ Transceiver 00MY770 ASK3 48 - 16 - - 192 384
10 Gb FC SFP+ transceivers
Brocade Secure 10Gb FC LWL SFP+ 4M27A65420 BF6E 48 - 16 - - 192 384
Brocade Secure 10Gb FC SWL SFP+ 4M27A65421 BF6F 48 - 16 - - 192 384
Brocade 10Gb FC SWL SFP+ Transceiver 00YH933 ATSY 48 - 16 - - 192 384
Brocade 10Gb FC LWL SFP+ Transceiver 00YH929 ATSX 48 - 16 - - 192 384
40 Gb Ethernet QSFP+ transceivers
Brocade 40Gb QSFP+ SR4 Optical Transceiver 01KN813 AVGL - - 2 - - 8 8
Brocade 40Gb QSFP+ LR4 Optical Transceiver 01KN817 AVGM - - 2 - - 8 8
Brocade 40Gb QSFP+ ER4 Optical Transceiver 01KN821 AVGN - - 2 - - 8 8
10 Gb Ethernet SFP+ transceivers
Brocade 10Gb SFP+ SR Optical Transceiver 49Y4216 0069 - - 16 - - 64 64
Brocade 10Gb SFP+ LR Optical Transceiver 95Y0540 A3AB - - 16 - - 64 64
Brocade 10GBASE-ZRD DWDM 80km SFP+ Transceiver 01KN837 AVGS - - 16 - - 64 64
1 Gb Ethernet SFP transceivers
Brocade 1000BASE-SX SFP Transceiver 01KN825 AVGP - - 16 - - 64 64
Brocade 1000BASE-LX SFP Transceiver 01KN829 AVGQ - - 16 - - 64 64
Brocade 1000BASE-T SFP Transceiver 01KN833 AVGR - - 16 - - 64 64
Optical cables for 128 Gb v2 / 4x16 Gb FC SWL, 40 Gb SR4 FCoE, and 40 GbE SR4 QSFP+ transceivers
Lenovo 10m QSFP+ MPO-MPO OM3 MMF Cable 00VX003 AT2U - 16 2 8 16 80 160
Lenovo 30m QSFP+ MPO-MPO OM3 MMF Cable 00VX005 AT2V - 16 2 8 16 80 160
Optical breakout cables for 128 Gb v2 / 4x16 Gb FC SWL, 100 Gb / 40 Gb SR4 FCoE, and 40 GbE SR4 transceivers
Lenovo 1m MPO-4xLC OM3 MMF Breakout Cable 00FM412 A5UA - 16 2 8 16 80 160
Lenovo 3m MPO-4xLC OM3 MMF Breakout Cable 00FM413 A5UB - 16 2 8 16 80 160
Lenovo 5m MPO-4xLC OM3 MMF Breakout Cable 00FM414 A5UC - 16 2 8 16 80 160
OM3 optical cables for 16 Gb FC SWL, 32 Gb FC SWL, 40 Gb SR4 FCoE BiDi, and 1/10 GbE SFP+ transceivers
Lenovo 0.5m LC-LC OM3 MMF Cable 00MN499 ASR5 48 16 16 - - 192 384
Lenovo 1m LC-LC OM3 MMF Cable 00MN502 ASR6 48 16 16 - - 192 384
Lenovo 3m LC-LC OM3 MMF Cable 00MN505 ASR7 48 16 16 - - 192 384
Lenovo 5m LC-LC OM3 MMF Cable 00MN508 ASR8 48 16 16 - - 192 384
Lenovo 10m LC-LC OM3 MMF Cable 00MN511 ASR9 48 16 16 - - 192 384
Lenovo 15m LC-LC OM3 MMF Cable 00MN514 ASRA 48 16 16 - - 192 384
Lenovo 25m LC-LC OM3 MMF Cable 00MN517 ASRB 48 16 16 - - 192 384
Lenovo 30m LC-LC OM3 MMF Cable 00MN520 ASRC 48 16 16 - - 192 384
OM4 optical cables for 16 Gb FC SWL, 32 Gb FC SWL, 40 Gb SR4 FCoE BiDi, and 1/10 GbE SFP+ transceivers
Lenovo 0.5m LC-LC OM4 MMF Cable 4Z57A10845 B2P9 48 16 16 - - 192 384
Lenovo 1m LC-LC OM4 MMF Cable 4Z57A10846 B2PA 48 16 16 - - 192 384
Lenovo 3m LC-LC OM4 MMF Cable 4Z57A10847 B2PB 48 16 16 - - 192 384
Lenovo 5m LC-LC OM4 MMF Cable 4Z57A10848 B2PC 48 16 16 - - 192 384
Lenovo 10m LC-LC OM4 MMF Cable 4Z57A10849 B2PD 48 16 16 - - 192 384
Lenovo 15m LC-LC OM4 MMF Cable 4Z57A10850 B2PE 48 16 16 - - 192 384
Lenovo 25m LC-LC OM4 MMF Cable 4Z57A10851 B2PF 48 16 16 - - 192 384
Lenovo 30m LC-LC OM4 MMF Cable 4Z57A10852 B2PG 48 16 16 - - 192 384
UTP Category 6 cables (Green) for 1 GbE RJ-45 SFP transceivers and management ports
0.75m CAT6 Green Cable 00WE123 AVFW - - 16 2 2 68 68
1.0m CAT6 Green Cable 00WE127 AVFX - - 16 2 2 68 68
1.25m CAT6 Green Cable 00WE131 AVFY - - 16 2 2 68 68
1.5m CAT6 Green Cable 00WE135 AVFZ - - 16 2 2 68 68
3m CAT6 Green Cable 00WE139 AVG0 - - 16 2 2 68 68
10m CAT6 Green Cable 90Y3718 A1MT - - 16 2 2 68 68
25m CAT6 Green Cable 90Y3727 A1MW - - 16 2 2 68 68
UTP Category 6 cables (Blue) for 1 GbE RJ-45 SFP transceivers and management ports
0.6m Blue Cat5e Cable 40K5679 3801 - - 16 2 2 68 68
1.5m Blue Cat5e Cable 40K8785 3802 - - 16 2 2 68 68
3m Blue Cat5e Cable 40K5581 3803 - - 16 2 2 68 68
10m Blue Cat5e Cable 40K8927 3804 - - 16 2 2 68 68
25m Blue Cat5e Cable 40K8930 3805 - - 16 2 2 68 68

The following table lists the cabling requirements for the directors.

Table 5. DB400D and DB800D 32Gb FC SAN Director cabling requirements
Transceiver Standard Cable Connector
128 Gb (4x 32 Gb) Fibre Channel
128 Gb (4x 32 Gb) FC SWL QSFP+ v2 (4M27A08820) FC-PI-6

Up to 30 m with MPO-MPO MMF cables or up to 5 m with MPO-4xLC MMF breakout cables supplied by Lenovo (see Table 4).

850 nm 50 µ MPO-MPO MMF cable:
  • 32GFC: Up to 100 m (OM4) or up to 70 m (OM3).
  • 16GFC: Up to 125 m (OM4) or up to 100 m (OM3).
MPO
128 Gb (4x 32 Gb) FC 2km LWL QSFP+ (4M27A09986) FC-PI-6 32GFC: 1310 nm 9 µ LC-LC SMF cable up to 2 km. LC
64 Gb (4x 16 Gb) Fibre Channel
4x 16 Gb FC SWL QSFP+ (01KN805) FC-PI-5

Up to 30 m with MPO-MPO MMF cables or up to 5 m with MPO-4xLC MMF breakout cables supplied by Lenovo (see Table 4).

16GFC: 850 nm 50 µ MPO-MPO MMF cable up to 100 m (OM4) or up to 66 m (OM3).

MPO
4x 16 Gb FC LWL QSFP+ (01KN809) FC-PI-5 16GFC: Parallel 1310 nm 9 µ MPO-MPO SMF cables up to 2 km. MPO
32 Gb Fibre Channel
32 Gb FC SWL SFP+ (01KN789, 01KN793) FC-PI-6

Up to 30 m with LC-LC MMF cables supplied by Lenovo (see Table 4).

850 nm 50 µ LC-LC MMF cable:
  • 32GFC: Up to 100 m (OM4) or up to 70 m (OM3).
  • 16GFC: Up to 125 m (OM4) or up to 100 m (OM3).
  • 8GFC: Up to 190 m (OM4) or up to 150 m (OM3).
LC
32 Gb FC LWL SFP+ (01KN795, 01KN799) FC-PI-6 32GFC, 16GFC, 8GFC: 1310 nm 9 µ SMF cable up to 10 km. LC
16 Gb Fibre Channel
16 Gb FC LWL SFP+ (00MY768) FC-PI-5 1310 nm 9 µ SMF cable:
  • 16GFC, 8GFC: Up to 10 km.
  • 4GFC: Up to 30 km.
LC
16 Gb FC SWL SFP+ (88Y6393) FC-PI-5

Up to 30 m with LC-LC MMF cables supplied by Lenovo (see Table 4).

850 nm 50 µ LC-LC MMF cable:
  • 16GFC: Up to 125 m (OM4) or up to 100 m (OM3).
  • 8GFC: Up to 190 m (OM4) or up to 150 m (OM3).
  • 4GFC: Up to 400 m (OM4) or up to 380 m (OM3).
LC
16 Gb FC ELWL SFP+ (00MY770) FC-PI-5 16GFC: 1310 nm 9 µ SMF cable up to 25 km. LC
10 Gb Fibre Channel
10 Gb FC SWL SFP+ (00YH933) FC-10GFC 10GFC: 850 nm 50 µ LC-LC MMF cable up to 550 m (OM4) or up to 300 m (OM3). LC
10 Gb FC LWL SFP+ (00YH929) FC-10GFC 10GFC: 1310 nm 9 µ SMF cable up to 10 km. LC
100 Gb (4x 25 Gb) Fibre Channel over Ethernet
100Gb (4x25Gb) SR4 QSFP28 (4M27A09989) 100GBASE-SR4

Up to 5 m with MPO-4xLC MMF breakout cables supplied by Lenovo (see Table 4).

850 nm 50 µ MPO-4xLC MMF breakout cable up to 70 m (OM3) or up to 100 m (OM4).

MPO
40 Gb Fibre Channel over Ethernet
40Gb (4x10Gb) SR4 QSFP+ (4M27A09987) 40GBASE-SR4

Up to 30 m with MPO-MPO MMF cables or up to 5 m with MPO-4xLC MMF breakout cables supplied by Lenovo (see Table 4).

850 nm 50 µ MPO-MPO MMF cable or MPO-4xLC MMF breakout cable up to 100 m (OM3) or up to 150 m (OM4).

MPO
40Gb SR QSFP+ BiDi (4M27A09988) 40GBASE-SR BiDi

Up to 30 m with LC-LC MMF cables supplied by Lenovo (see Table 4).

850 nm 50 µ LC-LC MMF cable up to 100 m (OM3) or up to 150 m (OM4).

LC
40 Gb Ethernet
40 GbE SR4 QSFP+ (01KN813) 40GBASE-SR4

Up to 30 m with MPO-MPO MMF cables or up to 5 m with MPO-4xLC MMF breakout cables supplied by Lenovo (see Table 4).

850 nm 50 µ MPO-MPO MMF cable or MPO-4xLC MMF breakout cable up to 100 m (OM3) or up to 150 m (OM4).

MPO
40 GbE LR4 QSFP+ (01KN817) 40GBASE-LR4 1310 nm 9 µ SMF cable up to 10 km. LC
40 GbE ER4 QSFP+ (01KN821) 40GBASE-ER4 1310 nm 9 µ SMF cable up to 40 km. LC
10 Gb Ethernet
10 GbE SR SFP+ (49Y4216) 10GBASE-SR

Up to 30 m with LC-LC MMF cables supplied by Lenovo (see Table 4).

850 nm 50 µ LC-LC MMF cable up to 400 m (OM4) or up to 300 m (OM3).

LC
10 GbE LR SFP+ (95Y0540) 10GBASE-LR 1310 nm 9 µ SMF cable up to 10 km. LC
10 GbE  DWDM SFP+ (01KN837) 10GBASE-ZRD 1550 nm 9 µ SMF cable up to 80 km. LC
1 Gb Ethernet
1 GbE SX SFP (01KN825) 1000BASE-SX

Up to 30 m with LC-LC MMF cables supplied by Lenovo (see Table 4).

850 nm 50 µ LC-LC MMF cable up to 550 m.

LC
1 GbE LX SFP (01KN829) 1000BASE-LX 1310 nm 9 µ SMF cable up to 10 km. LC
1 GbE RJ-45 SFP (01KN833) 1000BASE-T UTP Category 5, 5E, or 6 up to 100 meters. RJ-45
Management ports
10/100/1000 Mb Ethernet port 1000BASE-T

Up to 25 m with UTP cables supplied by Lenovo (see Table 4).

UTP Category 5, 5E, or 6 up to 100 meters.

RJ-45
Serial port RS-232 DB-9/RJ-45-to-RJ-45 console cable (comes with the director). RJ-45

Firmware

For details on the latest features supported with the DB400D & DB800D FC SAN Directors, see the Administration Guide for the latest available Fabric OS version 9.0 and above:
https://www.broadcom.com/products/fibre-channel-networking/software/fabric-operating-system

The following optional features are available for the Lenovo FC SAN Directors:

  • UltraScale Inter-Chassis Link (ICL): Allows to interconnect up to 9 (full-mesh) or 12 (core-edge) ThinkSystem DB400D or DB800D, or a combination of both, or connect ThinkSystem DB400D or DB800D to Brocade DCX 8510 Backbones by using the QSFP+ ports on the core routing blades.
  • Integrated Routing: The FC-FC routing service provides Fibre Channel routing between two or more fabrics without merging those fabrics.

The following table lists ordering information for the optional features and bundles for the DB400D and DB800D 32Gb FC SAN Directors Models HC1.

Table 6. Optional features and bundles for DB400D and DB800D Models HC1
Description Part number Feature code Maximum quantity supported
Paper authorization licenses for ThinkSystem DB400D and DB800D
Lenovo DB400D/DB800D S/W, Integrated Routing 01KN889 AVH3 1
License and transceiver bundles for ThinkSystem DB400D
Gen 6 ICL SW License + 8x (4x32Gbps) v2 QSFPs for DB400D 4M27A08822 B147 2
Gen 5 ICL SW License + 8x (4x16Gb) 2km QSFPs for DB400D 01KN871 AVKA 2
License and transceiver bundles for ThinkSystem DB800D 
Gen 6 ICL SW License + 16x (4x32Gbps) v2 QSFPs for DB800D 4M27A08821 B146 2
Gen 5 ICL SW License + 8x (4x16Gb) 2km QSFPs for DB800D 01KN859 AVH0 2

The following table lists ordering information for the optional features and bundles for the DB400D and DB800D 32Gb FC SAN Directors Models HC1 and HC2.

Table 7. Optional features and bundles for DB400D and DB800D Models HC1 and HC2
Description Part number Feature code Maximum
quantity
supported
Electronic authorization bundles and licenses for ThinkSystem DB400D and DB800D
Lenovo DB400D/DB800D Integrated Routing 7S0C000KWW B3EK 1
License and transceiver bundles for ThinkSystem DB400D
Gen 6 ICL SW 8-port License + 8x (4x32Gbps) QSFPs V2 for DB400D 4M27A14149 B5AC 2
Gen 6 ICL SW 8-port License + 8x (4x32Gbps) 2km QSFP for DB400D 4M27A14152 B5AF 2
Gen 5 ICL SW 8-port License + 8x (4x16Gbps) 2km QSFPs for DB400D 4M27A14150 B5AD 2
License and transceiver bundles for ThinkSystem DB800D
Gen 6 ICL 16-port License + 16x (4x32Gbps) QSFPs V2 for DB800D 4M27A14148 B5AB 2
Gen 6 ICL SW 16-port License + 8x (4x32Gbps) 2km QSFP for DB800D 4M27A14151 B5AE 2
Gen 5 ICL 16-port License + 8x (4x16Gbps) 2km QSFPs for DB800D 4M27A14147 B5AA 2

Each Inter-Chassis Link (ICL) bundle includes Port on Demand (POD) licenses to activate a half of available QSFP+ ports on both CR blades in the chassis, that is, each ICL license activates four ports on each CR32-4 blade in the DB400D chassis and eight ports on each CR32-8 blade in the DB800D chassis.

Each ICL bundle also includes 8 (the DB400D bundles and the DB800D 2km QSFPs bundle) or 16 (the DB800D bundles excluding the 2km QSFPs bundles) QSFP+ transceivers to populate the activated ports.

The firmware entitlement is included in the warranty service upgrades for DB400D Model HC2 and DB800D Model HC2.

The Integrated Routing feature (7S0C000KWW) comes with its own 1-year firmware support entitlement. The options to extend entitlement for additional years of firmware support for the Integrated Routing feature are listed in the following table.

Table 8. Firmware support extension options for Integrated Routing
Description Part number Feature code
Lenovo DB400D/DB800D Integrated Routing Support Extension, 2-Years 7S0C000SWW S0FA
Lenovo DB400D/DB800D Integrated Routing Support Extension, 4-Years 7S0C000ZWW S0FH

Management software

Lenovo offers optional Brocade SANnav™ Management Portal and SANnav Global View software license subscriptions that provide comprehensive visibility into the SAN environment, allow administrators to quickly identify, isolate, and correct problems, and accelerate administrative tasks by simplifying and automating workflows.

SANnav Management Portal is a next-generation SAN management application with a simple browser-based user interface (UI) and with a focus on streamlining common workflows, such as configuration, zoning, deployment, monitoring, troubleshooting, reporting, and analytics.

Lenovo offers the following SANnav Management Portal subscriptions:

  • SANnav Management Portal Base: Designed for mid-sized SANs to manage up to 600 SAN switch ports only (SAN director ports can only be managed with the Enterprise edition).
  • SANnav Management Portal Enterprise: Designed for enterprise-class SANs to manage up to 15 000 SAN switch and director ports.

SANnav Management Portal supports all Brocade SAN switches and platforms that run the Fabric OS® version 7.4 or above, including Lenovo B300, B6505, B6510, DB610S, DB620S, DB400D, DB720S, DB730S, DB800D, Brocade Directors, and FC5022.

With SANnav Global View, administrators can quickly visualize the health, performance, and inventory of multiple SANnav Management Portal instances using a simple, intelligent dashboard and can easily navigate from a global view down to local environments to investigate points of interest. SANnav Global View is designed to manage up to 20 SANnav Management Portal instances.

For more information, refer to the SANnav Management Portal documentation:
http://www.broadcom.com/products/fibre-channel-networking/software/sannav-management-portal#documentation

The following table lists ordering information for the optional SANnav Management Portal and SANnav Global View management tools. After a client has an active SANnav license, Lenovo offers a “license extension/renewal”. This offering provides our clients the flexible to extend their subscription down to a specific end date. This allows clients the ability to align to your company’s budget or align with warranty of your FC SAN switches/directors. Please engage directly with your Lenovo sales representative for more details.

Table 9. SANnav Management Portal and SANnav Global View subscription licenses
Part number Feature code Description
SANnav Management Portal electronic authorization licenses
7S0C0010WW S1K6 Brocade SANnav Mgmt Portal Base Edition - 1YR License 600 ports
7S0C0013WW S1K8 Brocade SANnav Mgmt Portal Base Edition - 3YR License 600 ports
7S0C001KWW S4MB Brocade SANnav Mgmt Portal Base Edition - 5YR License 600 ports
7S0C0011WW S1K7 Brocade SANnav Mgmt Portal Enterprise Edition - 1YR License 15K ports
7S0C0014WW S1K9 Brocade SANnav Mgmt Portal Enterprise Edition - 3YR License 15K ports
7S0C001LWW S4MC Brocade SANnav Mgmt Portal Enterprise Edition - 5YR License 15K ports
SANnav Global View electronic authorization licenses
7S0C0012WW S1D8 Brocade SANnav Global View - 1YR License
7S0C0015WW S1D9 Brocade SANnav Global View - 3YR License
7S0C001JWW S4MA Brocade SANnav Global View - 5YR License

The SANnav licenses are subscription-based with 1-year, 3-year, or 5-year software entitlement and support.

Fibre Channel standards

The SAN Directors supports the standards listed at the following web page:

https://www.broadcom.com/support/fibre-channel-networking/san-standards/standards-compliance

Ethernet standards

The DB400D and DB800D 32Gb FC SAN Directors support the following Ethernet standards:

  • IEEE 802.1AB Data Center Bridging Capability Exchange Protocol (DCBX)
  • IEEE 802.1p Class of Service (CoS) prioritization
  • IEEE 802.1Q VLAN Tagging
  • IEEE 802.1Qbb Priority-Based Flow Control (PFC)
  • IEEE 802.1Qaz Enhanced Transmission Selection (ETS)
  • IEEE 802.3 10BASE-T Ethernet (CP management interfaces)
  • IEEE 802.3u 100BASE-TX Fast Ethernet (CP management interfaces)
  • IEEE 802.3z 1000BASE-SX short range fiber optics Gigabit Ethernet
  • IEEE 802.3z 1000BASE-LX long range fiber optics Gigabit Ethernet
  • IEEE 802.3ab 1000BASE-T copper twisted pair Gigabit Ethernet
  • IEEE 802.3ae 10GBASE-SR short range fiber optics 10 Gb Ethernet
  • IEEE 802.3ae 10GBASE-LR long range fiber optics 10 Gb Ethernet
  • IEEE 802.3ba 40GBASE-SR4 short range fiber optics 40 Gb Ethernet
  • IEEE 802.3ba 40GBASE-LR4 long range fiber optics 40 Gb Ethernet
  • IEEE 802.3bm 40GBASE-ER4 extended range fiber optics 40 Gb Ethernet
  • IEEE 802.3bm 100GBASE-SR4 short range fiber optics 100 Gb Ethernet
  • 10GBASE-ZRD DWDM fiber optics 10 Gb Ethernet

Cooling

The DB400D and DB800D 32Gb FC SAN Directors ship without cooling modules (fan assemblies); the cooling modules must be ordered together with the ThinkSystem DB400D and DB800D. Each cooling module has two integrated fans that provide non-port side air intake.

Two cooling modules are required for the ThinkSystem DB400D, and three cooling modules are required for the ThinkSystem DB800D. Cooling modules provide N + 1 fan redundancy (3 + 1 for the DB400D; 5 + 1 for the DB800D), and the device can continue operation while one fan assembly is replaced if the fan assembly is replaced immediately.

The following table lists the cooling modules for the DB400D and DB800D 32Gb FC SAN Directors.

Table 10. Power supplies
Description Part number Feature code Quantity
DB400D DB800D
FC SAN Director Fan Tray (Non-port side Intake for DB400D/DB800D) 01KN895 AVGY 2 3

Power supplies and cables

The DB400D and DB800D 32Gb FC SAN Directors ship without power supplies; at least a minimum required quantity of the power supplies must be ordered together with the ThinkSystem DB400D and DB800D. Two power supplies are required for the ThinkSystem DB400D, and a minimum of three power supplies is required for the ThinkSystem DB800D. The forth power supply can be added to the ThinkSystem DB800D to provide additional power redundancy in certain configurations.

The power supplies are hot-swap 1450 W (100 - 120 V AC) / 2870 W (200 - 240 V AC), and each power supply has an IEC 320-C20 connector. Each power supply has two integrated fans that provide non-port side air intake that matches the airflow of the cooling modules.

The following table lists the power supplies for the DB400D and DB800D 32Gb FC SAN Directors.

Table 11. Power supplies
Description Part number Feature code Quantity (min / max)
DB400D DB800D
FC SAN Director PSU (Non-port side Intake for DB400D/DB800D) 01KN892 AVGX 2 / 2 3 / 4*
FC SAN Director PSU (Non-Port Side Intake for DB400D/DB800D) 4M27A36850 BBCU 2 / 2 3 / 4*

* In most scenarios, it is recommended to have 4 power supplies installed in the DB800D due to typical dual-PDU configurations with redundant power sources.

The power supply redundancy depends on the blade and port configuration and the AC input voltage level, as shown in the following table.

Table 12. Power supply redundancy
Model Power
supply
quantity
Configured ports Redundancy
100 - 120 V AC 200 - 240 V AC
DB400D 2 Any combination of ports and QSFP ICLs No N + N
DB800D 3 144x 32 Gbps ports and QSFP ICLs N+1 N + 2
Any other combination of ports and QSFP ICLs No N + 1
4 144x 32 Gbps ports and QSFP ICLs N+N N + 3
Any other combination of ports and QSFP ICLs No N + N

The FC SAN directors come standard without power cords; up to four rack power cables or line cords should be ordered for the FC SAN Directors depending on the quantity of power supplies.

The following table lists power cords for the DB400D and DB800D 32Gb FC SAN Directors.

Table 13. Power cord options
Description Part number Feature code
Rack power cables
2.5m, 16A/125-250V, C19 to IEC 320-C20 Rack Power Cable 39Y7916 6252
Line cords
Argentina 4.3m, 16A/250V, C19 to IRAM 2073 Line Cord 40K9777 6276
Brazil 4.3m, 16A/250V, C19 to NBR 14136 Line Cord 40K9775 6277
China 4.3m, 16A/250V, C19 to GB2099.1 Line Cord 40K9774 6288
India 4.3m, 16A/250V, C19 to IS6538 Line Cord 40K9776 6285
Israel 4.3m, 16A/250V, C19 to SI 32 Line Cord 40K9771 6282
Italy 4.3m, 16A/250V, C19 to CEI 23-16 Line Cord 40K9768 6281
Japan 4.3m, 15A/100V, C19 to JIS C-8303 Line Cord 41Y9232 6290
Japan 4.3m, 15A/200V, C19 to JIS C-8303 Line Cord 41Y9233 6291
Korea 4.3m, 15A/250V, C19 to KSC 8305 Line Cord 41Y9231 6289
South Africa 4.3m, 16A/250V, C19 to SABS 164 Line Cord 40K9770 6280
Switzerland 4.3m, 16A/250V, C19 to SEV 1011 Line Cord 81Y2391 6549
Taiwan 4.3m, 16A/125V, C19 to CNS 10917-3 Line Cord 41Y9229 6286
Taiwan 4.3m, 16A/250V, C19 to CNS 10917-3 Line Cord 41Y9230 6287
United Kingdom 4.3m, 13A/250V, C19 to BS 1363/A Line Cord 40K9767 6278
United States 4.3m, 15A/125V, C19 to NEMA 5-15P Line Cord 4L67A08372 B0RV
United States 4.3m, 15A/250V, C19 to NEMA 6-15P Line Cord 00D7197 A1NV

Rack installation

The DB400D and DB800D 32Gb FC SAN Directors come standard with the adjustable 27" to 31" rack mount kits that can be used for 4-post rack installations. The ThinkSystem DB400D also supports the optional Airflow Diversion Kits that allow to divert the airflow from the side air vent to the port side. In addition, the Lenovo DB800D supports 22" rack mount kit for specific racks.

If required, the Lenovo FC SAN Directors can be mounted in a 2-post rack cabinet by using the optional mid-mount rack kits.

The following table lists rack-mount options for the DB400D and DB800D 32Gb FC SAN Directors.

Table 14. Rack-mount options
Description Part number Feature code Maximum quantity supported
ThinkSystem DB400D rack-mount options
Lenovo DB400D mid-mount rack kit 01KN874 AVKB 1
27-31" Airflow Diversion Kit for Lenovo DB400D 01KN877 AVKC 1*
18-24" Airflow Diversion Kit for Lenovo DB400D 01KN880 AVKD 1*
ThinkSystem DB800D rack-mount options
Lenovo DB800D 22" rack mount kit 01KN883 AVH1 1
Lenovo DB800D mid-mount rack kit 01KN886 AVH2 1

* 27-31" and 18-24" Airflow Diversion Kits are mutually exclusive. Only one of these kits should be ordered, depending on the depth of the rack cabinet.

The optional airflow diversion kit for the DB400D 32Gb FC Director is shown in the following figure.

DB400 Airflow Diversion Kit
Figure 9. DB400D Airflow Diversion Kit

The optional mid-mount rack kits for the DB400D and DB800D 32Gb FC SAN Directors are shown in the following figure.

ThinkSystem DB400D (Left) and DB800D (Right) Mid-mount Rack Kits
Figure 10. ThinkSystem DB400D (Left) and DB800D (Right) Mid-mount Rack Kits

In addition, in order for the DB400D and DB800D 32Gb FC SAN Directors to meet FIPS 140-2 Level 2 Physical Security requirements the tamper-evident seals must be installed (see the following table for ordering information).

Table 15. Tamper-evident security seals
Description Part number Feature code Maximum quantity supported
Brocade FIPS 140-2 High Security Labels and Seals 01KN785 AVGB 1

Physical specifications

The DB400D and DB800D 32Gb FC SAN Directors have the following dimensions and weight (approximate):

  • Height:
    • DB400D: 345 mm (13.6 in.)
    • DB800D: 612 mm (24.1 in.)
  • Width: 437 mm (17.2 in.)
  • Depth: 611 mm (24.0 in.)
  • Weight:
    • DB400D:
      • Empty: 24.5 kg (54.0 lb)
      • Fully configured: 69.0 kg (152.0 lb)
    • DB800D:
      • Empty: 35.6 kg (78.5 lb)
      • Fully configured: 145.8 kg (321.5 lb)

Operating environment

The DB400D and DB800D 32Gb FC SAN Directors are supported in the following environment:

  • Air temperature:
    • Operating: 0°C to 40°C (32°F to 104°F)
    • Non-operating: -25°C to +70°C (-13°F to 158°F)
  • Maximum altitude:
    • Operating: 3,000 m (9,842 ft)
    • Non-operating: 12,000 m (39,370 ft)
  • Humidity:
    • Operating: 5% to 93% non-condensing with 10% per hour maximum rate of change
    • Non-operating: 10% to 93% non-condensing
  • Electrical power:
    • Voltage range: 100 V AC - 240 V AC (nominal)
    • Frequency: 50 Hz / 60 Hz (nominal)
    • Power consumption:
      • DB400D:
        • Idle: 840 watts
        • Typical: 1407 watts (FC32-48) / 1548 watts (FC32-64)
        • Maximum: 2438 watts (FC32-48) / 2953 watts (FC32-64)
      • DB800D:
        • Idle: 1515 watts
        • Typical: 2647 watts (FC32-48) / 2933 watts (FC32-64)
        • Maximum: 4339 watts (FC32-48) / 5380 watts (FC32-64)
  • Heat dissipation:
    • DB400D:
      • Idle: 2867 BTU per hour
      • Typical: 4802 BTU per hour (FC32-48) / 5283 BTU per hour (FC32-64)
      • Maximum: 8322 BTU per hour (FC32-48) / 10049 BTU per hour (FC32-64)
    • DB800D:
      • Idle: 5171 BTU per hour
      • Typical: 9034 BTU per hour (FC32-48) / 10010 BTU per hour (FC32-64)
      • Maximum: 14810 BTU per hour (FC32-48) / 18362 BTU per hour (FC32-64)
  • Acoustical noise emission:
    • DB400D: 64.2 dB
    • DB800D: 68.2 dB

Warranty upgrades and post-warranty support

The DB400D and DB800D 32Gb FC SAN Directors have a one-year warranty.

Our global network of regional support centers offers consistent, local-language support enabling you to vary response times and level of service to match the criticality of your support needs:

  • Standard Next Business Day – Best choice for non-essential systems requiring simple maintenance.
  • Premier Next Business Day – Best choice for essential systems requiring technical expertise from senior-level Lenovo engineers.
  • Premier 24x7 4-Hour Response – Best choice for systems where maximum uptime is critical.
  • Premier Enhanced Storage Support 24x7 4-Hour Response – Best choice for storage systems where maximum uptime is critical.

For more information, consult the brochure Lenovo Operational Support Services for Data Centers Services.

Services

Lenovo Data Center Services empower you at every stage of your IT lifecycle. From expert advisory and strategic planning to seamless deployment and ongoing support, we ensure your infrastructure is built for success. Our comprehensive services accelerate time to value, minimize downtime, and free your IT staff to focus on driving innovation and business growth.

Note: Some service options may not be available in all markets or regions. For more information, go to https://lenovolocator.com/. For information about Lenovo service upgrade offerings that are available in your region, contact your local Lenovo sales representative or business partner.

In this section:

Lenovo Advisory Services

Lenovo Advisory Services simplify the planning process, enabling customers to build future-proofed strategies in as little as six weeks. Consultants provide guidance on projects including VM migration, storage, backup and recovery, and cost management to accelerate time to value, improve cost efficiency, and build a flexibly scalable foundation.

  • Assessment Services

    An Assessment helps solve your IT challenges through an onsite, multi-day session with a Lenovo technology expert. We perform a tools-based assessment which provides a comprehensive and thorough review of a company's environment and technology systems. In addition to the technology based functional requirements, the consultant also discusses and records the non-functional business requirements, challenges, and constraints. Assessments help organizations like yours, no matter how large or small, get a better return on your IT investment and overcome challenges in the ever-changing technology landscape.

  • Design Services

    Professional Services consultants perform infrastructure design and implementation planning to support your strategy. The high-level architectures provided by the assessment service are turned into low level designs and wiring diagrams, which are reviewed and approved prior to implementation. The implementation plan will demonstrate an outcome-based proposal to provide business capabilities through infrastructure with a risk-mitigated project plan.

Lenovo Plan & Design Services

Unlock faster time to market with our tailored, strategic design workshops to align solution approaches with your business goals and technical requirements. Leverage our deep solution expertise and end-to-end delivery partnership to meet your goals efficiently and effectively.

Lenovo Deployment, Migration, and Configuration Services

Optimize your IT operations by shifting labor-intensive functions to Lenovo's skilled technicians for seamless on-site or remote deployment, configuration, and migration. Enjoy peace of mind, faster time to value, and comprehensive knowledge sharing with your IT staff, backed by our best-practice methodology.

  • Deployment Services for Storage and ThinkAgile

    A comprehensive range of remote and onsite options tailored specifically for your business needs to ensure your storage and ThinkAgile hardware are fully operational from the start.

  • Hardware Installation Services

    A full-range, comprehensive setup for your hardware, including unpacking, inspecting, and positioning components to ensure your equipment is operational and error-free for the most seamless and efficient installation experience, so you can quickly benefit from your investments.

  • DM/DG File Migration Services

    Take the burden of file migration from your IT’s shoulders. Our experts will align your requirements and business objectives to the migration plans while coordinating with your team to plan and safely execute the data migration to your storage platforms.

  • DM/DG/DE Health Check Services

    Our experts perform proactive checks of your Firmware and system health to ensure your machines are operating at peak and optimal efficiency to maximize up-time, avoid system failures, ensure the security of IT solutions and simplify maintenance.

  • Factory Integrated Services

    A suite of value-added offerings provided during the manufacturing phase of a server or storage system that reduces time to value. These services aim at improving your hardware deployment experience and enhance the quality of a standard configuration before it arrives at your facility.

Lenovo Support Services

In addition to response time options for hardware parts, repairs, and labor, Lenovo offers a wide array of additional support services to ensure your business is positioned for success and longevity. Our goal is to reduce your capital outlays, mitigate your IT risks, and accelerate your time to productivity.

  • Premier Support for Data Centers

    Your direct line to the solution that promises the best, most comprehensive level of support to help you fully unlock the potential of your data center.

  • Premier Enhanced Storage Support (PESS)

    Gain all the benefits of Premier Support for Data Centers, adding dedicated storage specialists and resources to elevate your storage support experience to the next level.

  • Committed Service Repair (CSR)

    Our commitment to ensuring the fastest, most seamless resolution times for mission-critical systems that require immediate attention to ensure minimal downtime and risk for your business. This service is only available for machines under the Premier 4-Hour Response SLA.

  • Multivendor Support Services (MVS)

    Your single point of accountability for resolution support across vast range of leading Server, Storage, and Networking OEMs, allowing you to manage all your supported infrastructure devices seamlessly from a single source.

  • Keep Your Drive (KYD)

    Protect sensitive data and maintain compliance with corporate retention and disposal policies to ensure your data is always under your control, regardless of the number of drives that are installed in your Lenovo server.

  • Technical Account Manager (TAM)

    Your single point of contact to expedite service requests, provide status updates, and furnish reports to track incidents over time, ensuring smooth operations and optimized performance as your business grows.

  • Enterprise Software Support (ESS)

    Gain comprehensive, single-source, and global support for a wide range of server operating systems and Microsoft server applications.

For more information, consult the brochure Lenovo Operational Support Services for Data Centers.

Lenovo Managed Services

Achieve peak efficiency, high security, and minimal disruption with Lenovo's always-on Managed Services. Our real-time monitoring, 24x7 incident response, and problem resolution ensure your infrastructure operates seamlessly. With quarterly health checks for ongoing optimization and innovation, Lenovo's remote active monitoring boosts end-user experience and productivity by keeping your data center's hardware performing at its best.

Lenovo Managed Services provides continuous 24x7 remote monitoring (plus 24x7 call center availability) and proactive management of your data center using state-of-the-art tools, systems, and practices by a team of highly skilled and experienced Lenovo services professionals.

Quarterly reviews check error logs, verify firmware & OS device driver levels, and software as needed. We’ll also maintain records of latest patches, critical updates, and firmware levels, to ensure you systems are providing business value through optimized performance.

Lenovo Sustainability Services

  • Asset Recovery Services

    Lenovo Asset Recovery Services (ARS) provides a secure, seamless solution for managing end-of-life IT assets, ensuring data is safely sanitized while contributing to a more circular IT lifecycle. By maximizing the reuse or responsible recycling of devices, ARS helps businesses meet sustainability goals while recovering potential value from their retired equipment. For more information, see the Asset Recovery Services offering page.

  • CO2 Offset Services

    Lenovo’s CO2 Offset Services offer a simple and transparent way for businesses to take tangible action on their IT footprint. By integrating CO2 offsets directly into device purchases, customers can easily support verified climate projects and track their contributions, making meaningful progress toward their sustainability goals without added complexity.

  • Lenovo Certified Refurbished

    Lenovo Certified Refurbished offers a cost-effective way to support IT circularity without compromising on quality and performance. Each device undergoes rigorous testing and certification, ensuring reliable performance and extending its lifecycle. With Lenovo’s trusted certification, you gain peace of mind while making a more sustainable IT choice.

Lenovo TruScale

Lenovo TruScale XaaS is your set of flexible IT services that makes everything easier. Streamline IT procurement, simplify infrastructure and device management, and pay only for what you use – so your business is free to grow and go anywhere.

Lenovo TruScale is  the unified solution that gives you simplified access to:

  • The industry’s broadest portfolio – from pocket to cloud – all delivered as a service
  • A single-contract framework for full visibility and accountability
  • The global scale to rapidly and securely build teams from anywhere
  • Flexible fixed and metered pay-as-you-go models with minimal upfront cost
  • The growth-driving combination of hardware, software, infrastructure, and solutions – all from one single provider with one point of accountability.

For information about Lenovo TruScale offerings that are available in your region, contact your local Lenovo sales representative or business partner.

Regulatory compliance

The DB400D and DB800D 32Gb FC SAN Directors conform to the following regulations:

  • Electromagnetic compatibility
    • FCC Part 15, Subpart B (Class A)
    • EN 55022 (CE mark) (Class A)
    • EN 55024 (CE mark)
    • ICES-003 (Canada) (Class A)
    • AS/NZ 55022 (Australia) (Class A)
    • VCCI (Japan) (Class A)
    • EN 61000-3-2
    • EN 61000-3-3
    • EN 61000-6-1
  • Safety
    • UL/CSA 60950
    • EN 60950
    • IEC 60950
  • Environmental: EU RoHS

Interoperability

For end-to-end storage configuration support, refer to the Lenovo Storage Interoperation Center (LSIC):
https://datacentersupport.lenovo.com/us/en/lsic

Use the LSIC to select the known components of your configuration and then get a list all other supported combinations, with details about supported hardware, firmware, operating systems, and drivers, plus any additional configuration notes. View results on screen or export them to Excel.

External storage systems

Lenovo offers the ThinkSystem DE Series and ThinkSystem DM Series external storage systems for high-performance storage. See the DE Series and DM Series product guides for specific controller models, expansion enclosures and configuration options:

External backup units

The following table lists the external backup options that are offered by Lenovo that can be used in Lenovo FC SAN solutions.

Note: Information provided in this section is for ordering reference purposes only. End-to-end LTO Ultrium configuration support for a particular tape backup unit must be verified through the System Storage Interoperation Center (SSIC):
http://www.ibm.com/systems/support/storage/ssic

Table 16. External Fibre Channel backup options
Part number Description
External tape backup libraries
6741A1F IBM TS4300 3U Tape Library-Base Unit
Fibre Channel backup drives for TS4300 Tape Library - Full Height
01KP935 LTO 6 FH Fibre Channel Drive
01KP938 LTO 7 FH Fibre Channel Drive
01KP954 LTO 8 FH Fibre Channel Drive
02JH837 LTO 9 FH Fibre Channel Drive
Fibre Channel backup drives for TS4300 Tape Library - Half Height
01KP933 LTO 6 HH Fibre Channel Drive
01KP936 LTO 7 HH Fibre Channel Drive
01KP952 LTO 8 HH Fibre Channel Drive
02JH835 LTO 9 HH Fibre Channel Drive

For more information, see the list of Product Guides in the Tape Autoloaders and Libraries category:
https://lenovopress.com/storage/tape/library

Rack cabinets

The following table lists the supported rack cabinets.

Table 17. Rack cabinets
ModelDescription
7D6DA007WWThinkSystem 42U Onyx Primary Heavy Duty Rack Cabinet (1200mm)
7D6DA008WWThinkSystem 42U Pearl Primary Heavy Duty Rack Cabinet (1200mm)
7D6EA009WWThinkSystem 48U Onyx Primary Heavy Duty Rack Cabinet (1200mm)
7D6EA00AWWThinkSystem 48U Pearl Primary Heavy Duty Rack Cabinet (1200mm)
93604PX42U 1200mm Deep Dynamic Rack
93604EX42U 1200mm Deep Dynamic Expansion Rack
93614PX42U 1200mm Deep Static Rack
93614EX42U 1200mm Deep Static Expansion Rack
93634PX42U 1100mm Dynamic Rack
93634EX42U 1100mm Dynamic Expansion Rack
93074RX42U Standard Rack (1000mm)
93084PX42U Enterprise Rack
93084EX42U Enterprise Expansion Rack

For specifications about these racks, see the Lenovo Rack Cabinet Reference, available from:
https://lenovopress.com/lp1287-lenovo-rack-cabinet-reference

For more information, see the list of Product Guides in the Rack cabinets category:
https://lenovopress.com/servers/options/racks

Power distribution units

The following table lists the power distribution units (PDUs) that are offered by Lenovo.

Table 18. Power distribution units
Part
number
Feature
code
Description
ANZ
ASEAN
Brazil
EET
MEA
RUCIS
WE
HTK
INDIA
JAPAN
LA
NA
PRC
0U Basic PDUs
4PU7A93176 C0QH 0U 36 C13 and 6 C19 Basic 32A 1 Phase PDU v2 Y Y Y Y Y Y Y Y Y N Y Y Y
4PU7A93169 C0DA 0U 36 C13 and 6 C19 Basic 32A 1 Phase PDU Y Y Y Y Y Y Y Y Y N Y Y Y
4PU7A93177 C0QJ 0U 24 C13/C15 and 24 C13/C15/C19 Basic 32A 3 Phase WYE PDU v2 Y Y Y Y Y Y Y Y Y Y Y Y Y
4PU7A93170 C0D9 0U 24 C13/C15 and 24 C13/C15/C19 Basic 32A 3 Phase WYE PDU Y Y Y Y Y Y Y Y Y N Y Y Y
00YJ776 ATZY 0U 36 C13/6 C19 24A 1 Phase PDU N Y Y N N N N N N Y Y Y N
00YJ779 ATZX 0U 21 C13/12 C19 48A 3 Phase PDU N N Y N N N Y N N Y Y Y N
00YJ777 ATZZ 0U 36 C13/6 C19 32A 1 Phase PDU Y Y N Y Y Y Y Y Y N N Y Y
00YJ778 AU00 0U 21 C13/12 C19 32A 3 Phase PDU Y Y N Y Y Y Y Y Y N N Y Y
0U Switched and Monitored PDUs
4PU7A93181 C0QN 0U 21 C13/C15 and 21 C13/C15/C19 Switched and Monitored 48A 3 Phase Delta PDU v2 (60A derated) N Y N N N N N Y N Y N Y N
4PU7A93174 C0D5 0U 21 C13/C15 and 21 C13/C15/C19 Switched and Monitored 48A 3 Phase Delta PDU (60A derated) N Y N Y N N Y Y N N N Y N
4PU7A93178 C0QK 0U 20 C13 and 4 C19 Switched and Monitored 32A 1 Phase PDU v2 Y Y Y Y Y Y Y Y Y N Y Y Y
4PU7A93171 C0D8 0U 20 C13 and 4 C19 Switched and Monitored 32A 1 Phase PDU Y Y Y Y Y Y Y Y Y N Y Y Y
4PU7A93182 C0QP 0U 18 C13/C15 and 18 C13/C15/C19 Switched and Monitored 63A 3 Phase WYE PDU v2 Y Y Y Y Y Y Y Y Y Y Y Y Y
4PU7A93175 C0CS 0U 18 C13/C15 and 18 C13/C15/C19 Switched and Monitored 63A 3 Phase WYE PDU Y Y Y Y Y Y Y Y Y N Y Y Y
4PU7A93180 C0QM 0U 18 C13/C15 and 18 C13/C15/C19 Switched and Monitored 32A 3 Phase WYE PDU v2 Y Y Y Y Y Y Y Y Y Y Y Y Y
4PU7A93173 C0D6 0U 18 C13/C15 and 18 C13/C15/C19 Switched and Monitored 32A 3 Phase WYE PDU Y Y Y Y Y Y Y Y Y N Y Y Y
4PU7A93179 C0QL 0U 16 C13/C15 and 16 C13/C15/C19 Switched and Monitored 24A 1 Phase PDU v2 (30A derated) N Y N N N N N Y N Y N Y N
4PU7A93172 C0D7 0U 16 C13/C15 and 16 C13/C15/C19 Switched and Monitored 24A 1 Phase PDU(30A derated) N Y N Y N N Y Y N N N Y N
00YJ783 AU04 0U 12 C13/12 C19 Switched and Monitored 48A 3 Phase PDU N N Y N N N Y N N Y Y Y N
00YJ781 AU03 0U 20 C13/4 C19 Switched and Monitored 24A 1 Phase PDU N N Y N Y N Y N N Y Y Y N
00YJ782 AU02 0U 18 C13/6 C19 Switched and Monitored 32A 3 Phase PDU Y Y Y Y Y Y Y Y Y N Y N Y
00YJ780 AU01 0U 20 C13/4 C19 Switched and Monitored 32A 1 Phase PDU Y Y Y Y Y Y Y Y Y N Y N Y
1U Switched and Monitored PDUs
4PU7A90808 C0D4 1U 18 C19/C13 Switched and monitored 48A 3P WYE PDU V2 ETL Y Y Y Y Y Y Y Y Y Y Y Y Y
4PU7A81117 BNDV 1U 18 C19/C13 switched and monitored 48A 3P WYE PDU - ETL N N N N N N N N N N N Y N
4PU7A90809 C0DE 1U 18 C19/C13 Switched and monitored 48A 3P WYE PDU V2 CE N N N N N Y Y N N N N N N
4PU7A81118 BNDW 1U 18 C19/C13 switched and monitored 48A 3P WYE PDU - CE Y Y Y Y Y Y Y Y Y N Y N Y
4PU7A90810 C0DD 1U 18 C19/C13 Switched and monitored 80A 3P Delta PDU V2 Y Y Y Y Y Y Y Y Y Y Y Y Y
4PU7A77467 BLC4 1U 18 C19/C13 Switched and Monitored 80A 3P Delta PDU N N N N N N N N N Y N Y N
4PU7A90811 C0DC 1U 12 C19/C13 Switched and monitored 32A 3P WYE PDU V2 N N N N N Y Y N N N N N N
4PU7A77468 BLC5 1U 12 C19/C13 switched and monitored 32A 3P WYE PDU Y Y Y Y Y Y Y Y Y Y Y Y Y
4PU7A90812 C0DB 1U 12 C19/C13 Switched and monitored 60A 3P Delta PDU V2 N N N N N N N N N Y N N N
4PU7A77469 BLC6 1U 12 C19/C13 switched and monitored 60A 3P Delta PDU N N N N N N N N N N N Y N
46M4002 5896 1U 9 C19/3 C13 Switched and Monitored DPI PDU Y Y Y Y Y Y Y Y Y Y Y Y Y
46M4004 5894 1U 12 C13 Switched and Monitored DPI PDU Y Y Y Y Y Y Y Y Y Y Y Y Y
46M4003 5897 1U 9 C19/3 C13 Switched and Monitored 60A 3 Phase PDU Y Y Y Y Y Y Y Y Y Y Y Y Y
46M4005 5895 1U 12 C13 Switched and Monitored 60A 3 Phase PDU Y Y Y Y Y Y Y Y Y Y Y Y Y
1U Ultra Density Enterprise PDUs (9x IEC 320 C13 + 3x IEC 320 C19 outlets)
71763NU 6051 Ultra Density Enterprise C19/C13 PDU 60A/208V/3PH N N Y N N N N N N Y Y Y N
71762NX 6091 Ultra Density Enterprise C19/C13 PDU Module Y Y Y Y Y Y Y Y Y Y Y Y Y
1U C13 Enterprise PDUs (12x IEC 320 C13 outlets)
39M2816 6030 DPI C13 Enterprise PDU Plus Module (WW) Y Y Y Y Y Y Y Y Y Y Y Y Y
39Y8941 6010 DPI C13 Enterprise PDU Module (WW) Y Y Y Y Y Y Y Y Y Y Y Y Y
1U C19 Enterprise PDUs (6x IEC 320 C19 outlets)
39Y8948 6060 DPI C19 Enterprise PDU Module (WW) Y Y Y Y Y Y Y Y Y Y Y Y Y
39Y8923 6061 DPI Three-phase 60A/208V C19 Enterprise PDU (US) N N Y N N N Y N N N Y Y N
1U Front-end PDUs (3x IEC 320 C19 outlets)
39Y8938 6002 DPI Single-phase 30A/120V Front-end PDU (US) Y Y Y Y Y Y Y Y Y Y Y Y Y
39Y8939 6003 DPI Single-phase 30A/208V Front-end PDU (US) Y Y Y Y Y Y Y Y Y Y Y Y Y
39Y8934 6005 DPI Single-phase 32A/230V Front-end PDU (International) Y Y Y Y Y Y Y Y Y Y Y Y Y
39Y8940 6004 DPI Single-phase 60A/208V Front-end PDU (US) Y N Y Y Y Y Y N N Y Y Y N
39Y8935 6006 DPI Single-phase 63A/230V Front-end PDU (International) Y Y Y Y Y Y Y Y Y Y Y Y Y
1U NEMA PDUs (6x NEMA 5-15R outlets)
39Y8905 5900 DPI 100-127V NEMA PDU Y Y Y Y Y Y Y Y Y Y Y Y Y
Line cords for 1U PDUs that ship without a line cord
40K9611 6504 4.3m, 32A/380-415V, EPDU/IEC 309 3P+N+G 3ph wye (non-US) Line Cord Y Y Y Y Y Y Y Y Y Y Y Y Y
40K9612 6502 4.3m, 32A/230V, EPDU to IEC 309 P+N+G (non-US) Line Cord Y Y Y Y Y Y Y Y Y Y Y Y Y
40K9613 6503 4.3m, 63A/230V, EPDU to IEC 309 P+N+G (non-US) Line Cord Y Y Y Y Y Y Y Y Y Y Y Y Y
40K9614 6500 4.3m, 30A/208V, EPDU to NEMA L6-30P (US) Line Cord Y Y Y Y Y Y Y Y Y Y Y Y Y
40K9615 6501 4.3m, 60A/208V, EPDU to IEC 309 2P+G (US) Line Cord N N Y N N N Y N N Y Y Y N
40K9617 6505 4.3m, 32A/230V, Souriau UTG Female to AS/NZ 3112 (Aus/NZ) Line Cord Y Y Y Y Y Y Y Y Y Y Y Y Y
40K9618 6506 4.3m, 32A/250V, Souriau UTG Female to KSC 8305 (S. Korea) Line Cord Y Y Y Y Y Y Y Y Y Y Y Y Y

For more information, see the Lenovo Press documents in the PDU category:
https://lenovopress.com/servers/options/pdu

Uninterruptible power supply units

The following table lists the uninterruptible power supply (UPS) units that are offered by Lenovo.

Table 19. Uninterruptible power supply units
Part number Description
Rack-mounted or tower UPS units - 100-125VAC
7DD5A001WW RT1.5kVA 2U Rack or Tower UPS-G2 (100-125VAC)
55941AX RT1.5kVA 2U Rack or Tower UPS (100-125VAC)
55942AX RT2.2kVA 2U Rack or Tower UPS (100-125VAC)
7DD5A003WW RT3kVA 2U Rack or Tower UPS-G2 (100-125VAC)
55943AX RT3kVA 2U Rack or Tower UPS (100-125VAC)
Rack-mounted or tower UPS units - 200-240VAC
7DD5A002WW RT1.5kVA 2U Rack or Tower UPS-G2 (200-240VAC)
55941KX RT1.5kVA 2U Rack or Tower UPS (200-240VAC)
55942KX RT2.2kVA 2U Rack or Tower UPS (200-240VAC)
7DD5A005WW RT3kVA 2U Rack or Tower UPS-G2 (200-240VAC)
55943KX RT3kVA 2U Rack or Tower UPS (200-240VAC)
7DD5A007WW RT5kVA 3U Rack or Tower UPS-G2 (200-240VAC)
55945KX RT5kVA 3U Rack or Tower UPS (200-240VAC)
7DD5A008WW RT6kVA 3U Rack or Tower UPS-G2 (200-240VAC)
55946KX RT6kVA 3U Rack or Tower UPS (200-240VAC)
55948KX RT8kVA 6U Rack or Tower UPS (200-240VAC)
7DD5A00AWW RT11kVA 6U Rack or Tower UPS-G2 (200-240VAC)
55949KX RT11kVA 6U Rack or Tower UPS (200-240VAC)
55943KT† ThinkSystem RT3kVA 2U Standard UPS (200-230VAC) (2x C13 10A, 2x GB 10A, 1x C19 16A outlets)
55943LT† ThinkSystem RT3kVA 2U Long Backup UPS (200-230VAC) (2x C13 10A, 2x GB 10A, 1x C19 16A outlets)
55946KT† ThinkSystem RT6kVA 5U UPS (200-230VAC) (2x C13 10A outlets, 1x Terminal Block output)
5594XKT† ThinkSystem RT10kVA 5U UPS (200-230VAC) (2x C13 10A outlets, 1x Terminal Block output)
Rack-mounted or tower UPS units - 380-415VAC
55948PX RT8kVA 6U 3:1 Phase Rack or Tower UPS (380-415VAC)
55949PX RT11kVA 6U 3:1 Phase Rack or Tower UPS (380-415VAC)

† Only available in China and the Asia Pacific market.

For more information, see the list of Product Guides in the UPS category:
https://lenovopress.com/servers/options/ups

Related product families

Product families related to this document are the following:

Trademarks

Lenovo and the Lenovo logo are trademarks or registered trademarks of Lenovo in the United States, other countries, or both. A current list of Lenovo trademarks is available on the Web at https://www.lenovo.com/us/en/legal/copytrade/.

The following terms are trademarks of Lenovo in the United States, other countries, or both:
Lenovo®
ThinkAgile®
ThinkSystem®

The following terms are trademarks of other companies:

UltraScale+™ and UltraScale™ are trademarks of Advanced Micro Devices, Inc.

Microsoft® and Excel® are trademarks of Microsoft Corporation in the United States, other countries, or both.

Other company, product, or service names may be trademarks or service marks of others.