Abstract
The Lenovo ThinkSystem DB400D and DB800D 32Gb FC SAN Directors combine innovative hardware, software, and integrated network sensors to ensure the highest levels of operational stability and application performance. Designed to enable maximum flexibility and reliability, the Lenovo FC SAN directors deliver market-leading 32 Gb Gen 6 Fibre Channel technology with modular building blocks for increased scalability to accommodate growth for large-scale enterprise infrastructures.
This product guide provides essential pre-sales information to understand the DB400D and DB800D 32Gb FC SAN Directors, their key features and specifications, components and options, and configuration guidelines.
This guide is intended for technical specialists, sales specialists, sales engineers, IT architects, and other IT professionals who want to learn more about the DB400D and DB800D 32Gb FC SAN Directors and consider their use in IT solutions.
Change History
Changes in the August 12, 2021
- All ThinkSystem DB400D and DB800D models are now withdrawn from marketing
Introduction
The Lenovo ThinkSystem DB400D and DB800D 32Gb FC SAN Directors combine innovative hardware, firmware, and integrated network sensors to ensure the highest levels of operational stability and application performance. Designed to enable maximum flexibility and reliability, the Lenovo FC SAN Directors deliver market-leading 32 Gb Gen 6 Fibre Channel technology with modular building blocks for increased scalability to accommodate growth for large-scale enterprise infrastructures.
The Lenovo FC SAN Directors provide full non-blocking performance with scalability of up to four (DB400D) or eight (DB800D) port blades to deliver up to 256x (DB400D) or 512x (DB800D) ports that are FC-capable with speeds up to 32 Gbps or FCoE-capable of speeds up to 25 Gbps. The Directors also offer FCoE support with up to 64x (DB400D) or 128x (DB800D) 40 Gbps FCoE ports.
The Lenovo FC SAN Directors offer FC over IP extension capabilities with support for up to 8x 40 GbE QSFP+ ports and up to 64x 1/10 GbE SFP+ ports with up to four extension blades. For inter-chassis connectivity, the Directors provide 16x (DB400D) or 32x (DB800D) FC QSFP+ ports that support 4x 16/32 Gbps speeds.
Figure 1. Lenovo ThinkSystem DB400D (Left) and DB800D (Right) 32Gb FC SAN Directors
Did you know?
The DB400D and DB800D 32Gb FC SAN Directors leverage storage connectivity technologies from Brocade, a leader in Fibre Channel networking.
Fabric Vision technology, an extension of Gen 6 Fibre Channel, provides unprecedented insight and visibility across the SAN with powerful built-in monitoring, management, and diagnostic tools.
With Lenovo FC SAN Switch offerings, Lenovo can be your trusted partner that offers "one stop shop" and single point of contact for delivery of leading-edge technologies and innovations from Lenovo and other leading IT vendors. These offerings can satisfy the wide range of your end-to-end IT infrastructure needs, including end-user devices, servers, storage, networking, services, management software, and financing.
Key features
The ThinkSystem DB400D and DB800D 32Gb FC SAN Directors offer the following features and benefits:
- Enhance operational stability, maximize application performance, and increase business agility with enterprise-class Gen 6 FC SAN directors
- Scale to 256 (DB400D) or 512 (DB800D) FC or FCoE ports with industry-leading port density and consolidate infrastructure with 128 Gbps Brocade UltraScale ICL connectivity for simpler, flatter, low-latency fabrics.
- Enable “pay-as-you-grow” scalability with full-fabric enterprise capabilities, supporting Fibre Channel connectivity of up to 32 Gbps or Fibre Channel over Ethernet (FCoE) connectivity of up to 40 Gbps.
- Accelerate application response time by up to 71 percent across 32 Gbps FC links.
- Optimize fabric behavior and ensure sufficient bandwidth for mission-critical applications with advanced traffic management capabilities and adaptive networking.
- Extend replication over distance with a highly scalable extension solution for Fibre Channel, IP, and FICON.
- Protect existing device investments with auto-sensing 4, 8, 16, and 32 Gbit/sec capabilities and native operation with Fabric OS-based fabrics.
- Simplify end-to-end management of large-scale environments by automating monitoring and diagnostics.
- Run Fabric OS, which delivers distributed intelligence throughout the network and enables a wide range of value-added features.
- Leverage Fabric Vision technology’s powerful monitoring, management, and diagnostic tools to simplify administration, increase uptime, and reduce costs.
- Provide proactive, non-intrusive, real-time monitoring and alerting of VM and storage I/O health and performance with VM Insight and IO Insight through integrated network sensors.
- Leverage predefined MAPS policies to automatically identify and isolate devices that cause network performance issues.
- Supply a rich set of standard features at no extra cost, including fabric services, advanced zoning, adaptive networking, integrated 10 Gb FC, diagnostic tools, ISL trunking, advanced monitoring and alerting, long-distance fabrics, and FICON CUP.
- Expand fabric capabilities with optional licensed functions, including Inter-Chassis Links (ICLs) and FC-FC routing.
- Compress and encrypt in-flight data on up to four ports for more efficient link utilization and better security.
- Virtualize physical FC SAN switches and fabrics into logical entities for better flexibility, utilization, management, and efficiency.
- Allow organizations to seamlessly integrate Gen 6 Fibre Channel networks with the next generation of flash storage – NVMe over Fibre Channel – by being NVMe-ready, without a disruptive rip and replace, to achieve faster application response times and harness the performance of solid state drives for better scalability across virtual data centers with flash storage.
- Help optimize the performance of NVMe with real-time latency monitoring on the FC32-64 port blade.
- Designed to provide 99.999% uptime capabilities and maximize resiliency with redundant hot-swap components, including power supplies, cooling modules, blades, transceivers, online diagnostics, and non-disruptive firmware download and activation.
- Accelerate troubleshooting with built-in advanced diagnostics tools featuring ClearLink Diagnostics with D_Ports and select adapters from QLogic and Emulex, which helps ensure optical and signal integrity for 16 Gb and 32 Gb Fibre Channel optics and cables.
- Automate repetitive daily tasks (such as fabric inventory, provisioning, and operational state monitoring) by using the standard REST APIs available directly from the switch.
- Simplify common SAN management practices by quickly integrating systems with open source PyFOS, a Python language.
Components and connectors
The following figure shows the port-side view of the DB400D 32Gb FC SAN Director.
Figure 2. DB400D 32Gb FC SAN Director port-side view
The port side of the DB400D chassis has the following components:
- Two redundant hot-swap active/standby Control Processor blades (CP blades come with the chassis)
A Control Processor (CP) blade contains the control plane for the device and hosts the Fabric OS that manages all hardware within the device, and it provides the following external connections for device configuration, firmware downloads, service, management, and monitoring functions:
- USB port for firmware download and technical support data
- Serial console RJ-45 port
- 10/100/1000 Mb Ethernet RJ-45 port for device management and configuration
- 10/100/1000 Mb Ethernet RJ-45 port for service
- 10 Gb Ethernet RJ-45 port (reserved for future use)
Note: The two 10/100/1000 Mb Ethernet ports are configured in an active/standby pair.
- Two redundant hot-swap active/active Core Routing CR32-4 blades (CR blades come with the chassis)
Core routing blades contain ASICs that allow switching between up to four port blades, and each core routing blade provides 96 Fibre Channel backplane ports for port or extension blade connections and 32 front-end FC links that are mapped to 8 QSFP+ ports for inter-chassis links (ICLs).
- Four hot-swap slots for port blades and extension blades (The chassis comes without port blades or extension blades, see Blades for ordering information)
The following figure shows the non-port side view of the DB400D 32Gb FC SAN Director.
Figure 3. DB400D 32Gb FC SAN Director non-port side view
The non-port side of the DB400D chassis has the following components:
- Two hot-swap power supplies (must be ordered together with the chassis)
- Two hot-swap cooling modules (must be ordered together with the chassis)
The following figure shows the port-side view of the DB800D 32Gb FC SAN Director.
Figure 4. DB800D 32Gb FC SAN Director port-side view
The port side of the DB800D chassis has the following components:
- Two redundant hot-swap active/standby Control Processor blades (CP blades come with the chassis)
A Control Processor (CP) blade contains the control plane for the device and hosts the Fabric OS that manages all hardware within the device, and it provides the following external connections for device configuration, firmware downloads, service, management, and monitoring functions:
- USB port for firmware download and technical support data
- Serial console RJ-45 port
- 10/100/1000 Mb Ethernet RJ-45 port for device management and configuration
- 10/100/1000 Mb Ethernet RJ-45 port for service
- 10 Gb Ethernet RJ-45 port (reserved for future use)
- Two redundant hot-swap active/active Core Routing CR32-8 blades (CR blades come with the chassis)
Core routing blades contain ASICs that allow switching between up to eight port blades, and each core routing blade provides 192 Fibre Channel backplane ports for port or extension blade connections and 64 front-end FC links that are mapped to 16 QSFP+ ports for inter-chassis links (ICLs).
- Eight hot-swap slots for port blades and extension blades (The chassis comes without port blades or extension blades, see Blades for ordering information)
The following figure shows the non-port side view of the DB800D 32Gb FC SAN Director.
Figure 5. DB800D 32Gb FC SAN Director non-port side view
The non-port side of the DB800D chassis has the following components:
- Three or four hot-swap power supplies (must be ordered together with the chassis)
- Three hot-swap cooling modules (must be ordered together with the chassis)
The following figure shows the FC32-64 port blade.
Figure 6. FC32-64 port blade
The FC32-64 port blade contains 16 QSFP+/QSFP28 ports can be split out into four Fibre Channel ports capable of speeds up to 32 Gbps or four FCoE ports capable of 10 Gbps or 25 Gbps speeds. Each QSFP+ port is also capable of supporting 40 Gbps FCoE. The FC32-64 port blade enables industry-leading platform density for Gen 6 SAN configurations supporting up to 256 32-Gbps external ports in a single DB400D chassis, and up to 512 32-Gbps external ports in a single DB800D chassis.
The following figure shows the FC32-48 port blade.
Figure 7. FC32-48 port blade
The FC32-48 port blade contains 48 ports capable of Fibre Channel speeds up to 32 Gbps. The FC32-48 port blade enables Gen 6 SAN configurations supporting up to 192 32-Gbps external ports in a single DB400D chassis, and up to 384 32-Gbps external ports in a single DB800D chassis.
The following figure shows the SX6 extension blade.
Figure 8. SX6 extension blade
The SX6 Extension blade is intended as an extension platform to support Fibre Channel, FICON, and IP based storage data flows. Extension features enable you to use the existing IP wide area network (WAN) infrastructure to connect Fibre Channel and IP fabrics. Extension features support applications such as remote data replication (RDR), centralized backup, and data migration over very long distances. Extension tunnels, built on a physical connection between two extension switches or blades, allow Fibre Channel and IP I/O to pass through the IP WAN. The SX6 Extension blade can connect with an SX6 blade in another DB400D or DB800D 32Gb FC SAN Director or with a Brocade 7840 Extension Switch.
System specifications
The following table lists the ThinkSystem DB400D and DB800D 32Gb FC SAN Director system specifications.
Note: The supported hardware options and firmware features listed in this product guide are based on the Fabric OS version 8.2. For details about specific firmware releases that introduced support for certain hardware options and firmware features, refer to the Release notes of the particular firmware release that can be found at:
http://datacentersupport.lenovo.com/us/en/products/storage/fibre-channel-switches/db400d-fc-switch/6682/downloads
http://datacentersupport.lenovo.com/us/en/products/storage/fibre-channel-switches/db800d-fc-switch/6684/downloads
Attribute | Specification | |
---|---|---|
DB400D | DB800D | |
Machine type | 6684 | 6682 |
Form factor | 8U rack mount 9U rack mount with the airflow diversion kit |
14U rack mount |
Blades |
|
|
Ports |
|
|
|
||
Media types |
|
|
Port speeds |
|
|
FC port types |
|
|
Data traffic types | Unicast (Class 2 and Class 3), multicast (Class 3 only), broadcast (Class 3 only). | |
Classes of service | Class 2, Class 3, Class F (inter-switch frames). | |
Standard features | Full Fabric, Advanced Zoning, Fabric Services, 10 Gb FC, Adaptive Networking, Advanced Diagnostic Tools, Virtual Fabrics, In-flight Compression, In-flight Encryption, ISL Trunking, Fabric Vision, Extended Fabric, FICON CUP (except FC32-64 port blade). | |
Optional features | UltraScale Inter-Chassis Links (ICLs), Integrated Routing. | |
Architecture | Non-blocking shared memory; passive backplane; redundant active/passive control processor; redundant active/active core switching blades; redundant WWN cards. | |
Performance |
|
|
Aggregated throughput | 10.24 Tbps | 20.48 Tbps |
Scalability |
|
|
Cooling | 2x Hot-swap cooling modules required; each module contains two fans. N+1 (3+1) fan redundancy. Non-port side to side vent (default) or non-port to port side (optional) airflow. | 3x Hot-swap cooling modules required; each module contains two fans. N+1 (5+1) fan redundancy. Non-port to port side airflow. |
Power supply type | 1450 W (100 - 120 V AC) / 2870 W (200 - 240 V AC) hot-swap power supply (IEC 309-C20 connector). | |
Power supply quantity | 2 required | 3 required; 4 maximum |
Hot-swap parts | Blades, SFP+/QSFP+ transceivers, power supplies, cooling modules. | |
Management ports | Per control processor blade:
|
|
Management interfaces | Web-based GUI (Web Tools); Command Line Interface (CLI); SMI-S; SNMP; REST API. Optional Brocade SANnav Management Portal and SANnav Global View, or Brocade Network Advisor. | |
Security features | Secure Socket Layer (SSL); Secure Shell (SSH); Secure Copy (SCP); Secure FTP (SFTP); user level security, Role-based Access Control (RBAC); LDAP, RADIUS, and TACACS+ authentication; access control lists (ACLs) | |
Hardware warranty | One-year customer-replaceable unit limited warranty with 9x5 next business day parts delivered. | |
Service and support | Optional service upgrades are available through Lenovo Services: 9x5 next business day onsite response, 24x7 2-hour or 4-hour onsite response, 24x7 6-hour or 24-hour committed service repair, up to 5 years of warranty coverage, and 1-year or 2-year post-warranty extensions. | |
Firmware entitlement | One-year (DB400D and DB800D Models HC2) or three-year (DB400D and DB800D Models HC1) firmware entitlement and support license is included. Optional one- and two-year firmware support extension licenses are available from Lenovo for DB400D and DB800D Models HC1. Firmware entitlement extension licenses for DB400D and DB800D Models HC2 are included in the warranty service upgrades for DB400D and DB800D Models HC2. | |
Dimensions |
|
|
Weight |
|
|
Models
The following table lists the DB400D and DB800D 32Gb FC SAN Director models.
Withdrawn: All models are now withdrawn from marketing
Description | Part number | Machine Type-Model |
Feature code |
---|---|---|---|
Lenovo ThinkSystem DB400D 32Gb FC Director, ENT. Feature set, 4 Blade slots, 8U, 1Yr FW | 6684D2A | 6684HC2 | B4QH |
Lenovo ThinkSystem DB400D 32Gb FC Director, ENT. Feature set, 4 Blade slots, 8U, 3Yr FW | 6684B2A | 6684HC1 | AVK7 |
Lenovo ThinkSystem DB800D 32Gb FC Director, ENT. Feature set, 8 Blade slots, 14U, 1Yr FW | 6682D1A | 6682HC2 | B4QG |
Lenovo ThinkSystem DB800D 32Gb FC Director, ENT. Feature set, 8 Blade slots, 14U, 3Yr FW | 6682B1A | 6682HC1 | AVGJ |
The DB400D and DB800D 32Gb FC SAN Director part numbers include the following items:
- One 32 Gb FC Director chassis that contains the following components:
- Two control blades
- Two core routing blades
- Chassis door
- Serial cable (DB-9/RJ-45 to RJ-45)
- Power cord retainer clips
- Cable management assembly
- Adjustable rack mount kit
- Ground lug kit
- Online Documentation web pointer card
- SANNav web pointer card
Configuration notes:
- The ThinkSystem DB400D and DB800D models come standard without port or extension blades; they should be ordered for the director model (See Blades for details).
- The ThinkSystem DB400D and DB800D models come standard without fan modules and power supplies; at least a minimum quantity required must be ordered together with the director model (See Cooling and Power supplies and cables for details).
- The ThinkSystem DB400D and DB800D models come standard without power cords; they must be ordered together with the director model (see Power supplies and cables for details).
Blades
The DB400D and DB800D 32Gb FC SAN Directors support the port and extension blade options that are listed in the following table.
Description | Part number | Feature code | Quantity | |
---|---|---|---|---|
DB400D | DB800D | |||
Port blades (for Models HC1 and HC2) | ||||
Lenovo Gen 6 Port Blade FC32-48 (no transceivers) | 01KN845 | AVGT | 4 | 8 |
Lenovo Gen 6 Port Blade FC32-48 (48 transceivers, 32Gbps) | 01KN848 | AVGU | 4 | 8 |
Lenovo Gen 6 Port Blade FC32-64 (8 4x32Gb QSFP+ transceivers) | 4M27A09985 | B26X | 4 | 8 |
Extension blades (for Model HC1) | ||||
Lenovo SX6 FC-IP SAN Extension Blade + 16 32Gb SWL SFPs | 01KN850 | AVGV | 4 | 4 |
Lenovo SX6 FC-IP SAN Extension Blade + 16 32Gb LWL SFPs | 01KN854 | AVGW | 4 | 4 |
Extension blades (for Model HC2) | ||||
Lenovo SX6 FC-IP SAN Extension Blade + 16 32Gb SWL SFPs, 1YR | 4M27A14145 | B5Z7 | 4 | 4 |
Lenovo SX6 FC-IP SAN Extension Blade + 16 32Gb LWL SFPs, 1YR | 4M27A14146 | B5Z8 | 4 | 4 |
Port and extension blades come standard with all ports activated, and certain part numbers also include transceivers. Additional transceivers and cables can be ordered, if required (See Transceivers and cables for details).
Transceivers and cables
With the flexibility of the DB400D and DB800D 32Gb FC SAN Directors, customers can choose the following connectivity technologies:
- SFP+ ports on the FC32-48 port blade and SX6 extension blade
- For 32 Gb FC links, customers can use 32 Gb FC SFP+ SW optical transceivers for distances up to 100 meters on OM4 or up to 70 meters on OM3 50 µ multimode fiber (MMF) optic cables. For longer distances, the 32 Gb FC LW SFP+ optical transceivers can support up to 10 kilometers on 9 µ single-mode fiber (SMF) optic cables.
- For 16 Gb FC links, customers can use 16 Gb FC SFP+ SW optical transceivers for distances up to 125 meters on OM4 or up to 100 meters on OM3 50 µ MMF cables. For longer distances, the 16 Gb FC LW SFP+ optical transceivers can support up to 10 kilometers on 9 µ SMF cables. For extended distances, the 16 Gb FC ELW SFP+ optical transceivers can support up to 25 kilometers on 9 µ SMF cables.
- For 10 Gb FC links, customers can use 10 Gb FC SFP+ SW transceivers for distances up to 550 meters on OM4 or up to 300 meters on OM3 50 µ MMF cables, or 10 Gb FC SFP+ LW transceivers for distances up to 10 km on 9 µ SMF cables. 10 Gb FC operations allow metro connectivity by directly utilizing a fiber optic cable between sites or by creating multiple channels on an optical cable between sites, utilizing Wave Division Multiplexing (WDM) technology.
- QSFP+/QSFP28 ports on the FC32-64 port blade
- For 32 Gb FC links, customers can use the 128 Gb (4x 32 Gbps) SWL QSFP+ Transceiver with OM4 MMF MPO-4xLC breakout cables for distances up to 100 meters or OM3 MMF MPO-4xLC breakout cables for distances up to 70 meters. For longer-distance ISL links, the 128 Gb (4x 32 Gbps) FC LWL QSFP+ optical transceivers can support up to 2 kilometers on 9 µ SMF cables.
- For 16 Gb FC links, customers can use MMF MPO-4xLC breakout cables with the following transceivers:
- 128 Gb (4x 32 Gb) QSFP+ SWL optical transceivers running at 4x 16 Gb speeds for distances up to 125 meters on OM4 or up to 100 meters on OM3 MMF cables.
- 4x 16 Gb FC QSFP+ SWL optical transceivers for distances up to 100 meters on OM4 or up to 66 meters on OM3 MMF cables.
- For 40 Gb FCoE links, customers can use the 40 Gb SR4 QSFP+ bi-directional transceivers or 40 Gb (4x 10 Gbps) SR4 QSFP+ transceivers for distances up to 100 meters on OM3 or up to 150 meters on OM4 MMF cables.
- For 25 Gb FCoE links, customers can use the 100 Gb (4x 25 Gbps) QSFP28 SR4 transceiver for distances up to 70 meters on OM3 or up to 100 meters on OM4 MMF MPO-4xLC breakout cables.
- For 10 Gb FCoE links, customers can use the 40 Gb (4x 10 Gbps) SR4 QSFP+ transceivers for distances up to 100 meters on OM3 or up to 150 meters on OM4 MMF MPO-4xLC breakout cables.
- QSFP+ ports on the core routing blades:
- For 128 Gb FC inter-chassis links for connectivity between the DB400D or DB800D 32Gb FC Directors, customers can use 128 Gb (4x 32 Gb) FC QSFP+ SW optical transceivers for distances up to 100 meters on OM4 or up to 70 meters on OM3 50 µ MMF cables.
Note: ICL trunks are formed automatically with corresponding 32 Gbps ports on different QSFP+ transceivers (ICL trunks cannot be formed with the 4x 32 Gbps ports on the same QSFP+ transceiver), and the trunking license is not required. - For 64 Gb FC inter-chassis links for connectivity between the DB400D or DB800D 32Gb FC Directors and Brocade DCX 8510 Backbones, customers can use the following transceivers:
- 128 Gb (4x 32 Gb) QSFP+ SWL v2 optical transceivers running at 4x 16 Gb speeds for distances up to 125 meters on OM4 or up to 100 meters on OM3 50 µ MMF cables.
- 4x 16 Gb FC QSFP+ SWL optical transceivers for distances up to 100 meters on OM4 or up to 66 meters on OM3 50 µ MMF cables.
- 4x 16 Gb FC QSFP+ LWL optical transceivers for distances up to 2 kilometers on parallel 9 µ SMF cables.
- For 128 Gb FC inter-chassis links for connectivity between the DB400D or DB800D 32Gb FC Directors, customers can use 128 Gb (4x 32 Gb) FC QSFP+ SW optical transceivers for distances up to 100 meters on OM4 or up to 70 meters on OM3 50 µ MMF cables.
- 1/10 GbE SFP+ and 40 GbE QSFP+ ports on extension blades allow connection to IP WANs and allow Fibre Channel and IP I/O traffic to pass through the IP WAN through extension tunnels.
- For 1 GbE links, customers can use RJ-45 SFP transceivers with UTP cables up to 100 meters. Customers that need longer distances can use a 1000BASE-SX transceiver, which can drive distances up to 220 meters with 62.5 µ OM1 and up to 550 meters on 50 µ OM2 MMF cables, or the 1000BASE-LX transceivers that support distances up to 10 kilometers on 9 µ SMF cables.
- For 10 GbE links, customers can use a 10GBASE-SR transceiver that supports distances up to 300 meters on OM3 or up to 400 meters on OM4 50 µ MMF cables. For longer distances, the 10GBASE-LR transceivers can support distances up to 10 kilometers on 9 µ SMF cables.
For distances up to 80 km, customers can use the 10GBASE-ZRD Tunable DWDM optical transceiver on 9 µ SMF cables.
-
For 40 GbE links, customers can use the 40GBASE-SR4 QSFP+ transceivers for distances up to 100 meters on OM3 or up to 150 meters on OM4 50 µ MMF cables. For longer distances, the 40GBASE-LR4 transceivers can support distances up to 10 kilometers on 9 µ SMF cables. For extended distances, the 40GBASE-ER4 transceivers can support distances up to 40 kilometers on 9 µ SMF cables.
- 1 GbE RJ-45 management ports on control processor blades: Customers can use UTP cables for distances up to 100 meters.
The FC32-64 port blades come standard with 8x 128 Gb (4x 32 Gbps) SWL QSFP+ transceivers. The FC32-48 port blades come standard with or without 48x 32 Gb FC SWL SFP+ transceivers. The SX6 extension blades come standard with 16x 32 Gb FC SWL or LWL SFP+ transceivers. The optional ICL bundles include 8x or 16x 128 Gb FC or 64 Gb FC QSFP+ transceivers. Additional Fibre Channel or Ethernet SFP+ and QSFP+/QSFP28 transceivers can be ordered, if required.
The following table lists the supported SFP+ and QSFP+/QSFP28 transceiver options and optical cables.
Brocade secure transceivers: These new transceivers have features to ensure that you are using genuine Brocade components to maximize performance and reliability and to help avoid issues related to counterfeit products.
Description | Part number | Feature code | Maximum quantity supported | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Per blade | Per chassis | |||||||||||||||
FC32-48
|
FC32-64
|
SX6
|
CR32-4
|
CR32-8
|
DB400D
|
DB800D
|
||||||||||
QSFP+ FC transceivers | ||||||||||||||||
Brocade Secure 128Gb (4x 32Gb) SWL QSFP+ | 4M27A65422 | BF6G | - | 16 | - | 8 | 16 | 80 | 160 | |||||||
Brocade 128Gb (4x32Gbps) SWL QSFP+ Transceiver v2 | 4M27A08820 | B145 | - | 16 | - | 8 | 16 | 80 | 160 | |||||||
Brocade 128Gb (4x32Gbps) 2KM QSFP+ Transceiver | 4M27A09986 | B26T | - | 16 | - | 8 | 16 | 80 | 160 | |||||||
Brocade 4x16Gb FC-Compliant SWL QSFP+ Transceiver | 01KN805 | AVGH | - | 16 | - | 8 | 16 | 80 | 160 | |||||||
Brocade 4x16Gbps 2km LWL QSFP+ Transceiver | 01KN809 | AVGK | - | - | - | 8 | 16 | 16 | 32 | |||||||
QSFP+/QSFP28 FCoE transceivers | ||||||||||||||||
Brocade 100Gb (4x25GbE) QSFP28 SR4 FCoE Transceiver | 4M27A09989 | B26W | - | 16 | - | - | - | 64 | 128 | |||||||
Brocade 40Gb (4x10GbE) QSFP+ SR4 FCoE Transceiver | 4M27A09987 | B26U | - | 16 | - | - | - | 64 | 128 | |||||||
Brocade 40Gb QSFP+ SR4 FCoE Transceiver, BiDi | 4M27A09988 | B26V | - | 16 | - | - | - | 64 | 128 | |||||||
32 Gb FC SFP+ transceivers | ||||||||||||||||
Brocade Secure 32Gb SWL SFP+ Transceiver | 4M27A65416 | BF69 | 48 | - | 16 | - | - | 192 | 384 | |||||||
Brocade Secure 32Gb SWL SFP+ Transceiver (8-pack) | 4M27A65417 | BF6A | 6 | - | 2 | - | - | 24 | 48 | |||||||
Brocade Secure 32Gb LWL SFP+ Transceiver | 4M27A65418 | BF6B | 48 | - | 16 | - | - | 192 | 384 | |||||||
Brocade Secure 32Gb LWL SFP+ Transceiver (8-pack) | 4M27A65419 | BF6C | 6 | - | 2 | - | - | 24 | 48 | |||||||
Brocade Secure 32Gb ELWL SFP+ (25 km) | 4M27A65424 | BF6D | 48 | - | 16 | - | - | 192 | 384 | |||||||
Brocade 32Gb SWL SFP+ Transceiver | 01KN789 | AVGC | 48 | - | 16 | - | - | 192 | 384 | |||||||
Brocade 32Gb SWL SFP+ Transceiver (8-pack) | 01KN793 | AVGD | 6 | - | 2 | - | - | 24 | 48 | |||||||
Brocade 32Gb LWL SFP+ Transceiver | 01KN795 | AVGE | 48 | - | 16 | - | - | 192 | 384 | |||||||
Brocade 32Gb LWL SFP+ Transceiver (8-pack) | 01KN799 | AVGF | 6 | - | 2 | - | - | 24 | 48 | |||||||
16 Gb FC SFP+ transceivers | ||||||||||||||||
Brocade Secure 16Gb SWL SFP+ | 4M27A65411 | BF64 | 48 | - | 16 | - | - | 192 | 384 | |||||||
Brocade Secure 16Gb SWL SFP+ 8-pack | 4M27A65412 | BF65 | 6 | - | 2 | - | - | 24 | 48 | |||||||
Brocade Secure 16Gb LWL SFP+ (10 km) | 4M27A65413 | BF66 | 48 | - | 16 | - | - | 192 | 384 | |||||||
Brocade Secure 16Gb LWL SFP+ (10 km) 8pk | 4M27A65414 | BF67 | 6 | - | 2 | - | - | 24 | 48 | |||||||
Brocade Secure 16Gb ELWL SFP+ (25 km) | 4M27A65415 | BF68 | 48 | - | 16 | - | - | 192 | 384 | |||||||
Brocade 16Gb SWL SFP+ Optical Transceiver | 88Y6393 | A22R | 48 | - | 16 | - | - | 192 | 384 | |||||||
Brocade 16Gb 10km LWL SFP+ Transceiver | 00MY768 | ASK2 | 48 | - | 16 | - | - | 192 | 384 | |||||||
Brocade 16Gb 25km ELWL SFP+ Transceiver | 00MY770 | ASK3 | 48 | - | 16 | - | - | 192 | 384 | |||||||
10 Gb FC SFP+ transceivers | ||||||||||||||||
Brocade Secure 10Gb FC LWL SFP+ | 4M27A65420 | BF6E | 48 | - | 16 | - | - | 192 | 384 | |||||||
Brocade Secure 10Gb FC SWL SFP+ | 4M27A65421 | BF6F | 48 | - | 16 | - | - | 192 | 384 | |||||||
Brocade 10Gb FC SWL SFP+ Transceiver | 00YH933 | ATSY | 48 | - | 16 | - | - | 192 | 384 | |||||||
Brocade 10Gb FC LWL SFP+ Transceiver | 00YH929 | ATSX | 48 | - | 16 | - | - | 192 | 384 | |||||||
40 Gb Ethernet QSFP+ transceivers | ||||||||||||||||
Brocade 40Gb QSFP+ SR4 Optical Transceiver | 01KN813 | AVGL | - | - | 2 | - | - | 8 | 8 | |||||||
Brocade 40Gb QSFP+ LR4 Optical Transceiver | 01KN817 | AVGM | - | - | 2 | - | - | 8 | 8 | |||||||
Brocade 40Gb QSFP+ ER4 Optical Transceiver | 01KN821 | AVGN | - | - | 2 | - | - | 8 | 8 | |||||||
10 Gb Ethernet SFP+ transceivers | ||||||||||||||||
Brocade 10Gb SFP+ SR Optical Transceiver | 49Y4216 | 0069 | - | - | 16 | - | - | 64 | 64 | |||||||
Brocade 10Gb SFP+ LR Optical Transceiver | 95Y0540 | A3AB | - | - | 16 | - | - | 64 | 64 | |||||||
Brocade 10GBASE-ZRD DWDM 80km SFP+ Transceiver | 01KN837 | AVGS | - | - | 16 | - | - | 64 | 64 | |||||||
1 Gb Ethernet SFP transceivers | ||||||||||||||||
Brocade 1000BASE-SX SFP Transceiver | 01KN825 | AVGP | - | - | 16 | - | - | 64 | 64 | |||||||
Brocade 1000BASE-LX SFP Transceiver | 01KN829 | AVGQ | - | - | 16 | - | - | 64 | 64 | |||||||
Brocade 1000BASE-T SFP Transceiver | 01KN833 | AVGR | - | - | 16 | - | - | 64 | 64 | |||||||
Optical cables for 128 Gb v2 / 4x16 Gb FC SWL, 40 Gb SR4 FCoE, and 40 GbE SR4 QSFP+ transceivers | ||||||||||||||||
Lenovo 10m QSFP+ MPO-MPO OM3 MMF Cable | 00VX003 | AT2U | - | 16 | 2 | 8 | 16 | 80 | 160 | |||||||
Lenovo 30m QSFP+ MPO-MPO OM3 MMF Cable | 00VX005 | AT2V | - | 16 | 2 | 8 | 16 | 80 | 160 | |||||||
Optical breakout cables for 128 Gb v2 / 4x16 Gb FC SWL, 100 Gb / 40 Gb SR4 FCoE, and 40 GbE SR4 transceivers | ||||||||||||||||
Lenovo 1m MPO-4xLC OM3 MMF Breakout Cable | 00FM412 | A5UA | - | 16 | 2 | 8 | 16 | 80 | 160 | |||||||
Lenovo 3m MPO-4xLC OM3 MMF Breakout Cable | 00FM413 | A5UB | - | 16 | 2 | 8 | 16 | 80 | 160 | |||||||
Lenovo 5m MPO-4xLC OM3 MMF Breakout Cable | 00FM414 | A5UC | - | 16 | 2 | 8 | 16 | 80 | 160 | |||||||
OM3 optical cables for 16 Gb FC SWL, 32 Gb FC SWL, 40 Gb SR4 FCoE BiDi, and 1/10 GbE SFP+ transceivers | ||||||||||||||||
Lenovo 0.5m LC-LC OM3 MMF Cable | 00MN499 | ASR5 | 48 | 16 | 16 | - | - | 192 | 384 | |||||||
Lenovo 1m LC-LC OM3 MMF Cable | 00MN502 | ASR6 | 48 | 16 | 16 | - | - | 192 | 384 | |||||||
Lenovo 3m LC-LC OM3 MMF Cable | 00MN505 | ASR7 | 48 | 16 | 16 | - | - | 192 | 384 | |||||||
Lenovo 5m LC-LC OM3 MMF Cable | 00MN508 | ASR8 | 48 | 16 | 16 | - | - | 192 | 384 | |||||||
Lenovo 10m LC-LC OM3 MMF Cable | 00MN511 | ASR9 | 48 | 16 | 16 | - | - | 192 | 384 | |||||||
Lenovo 15m LC-LC OM3 MMF Cable | 00MN514 | ASRA | 48 | 16 | 16 | - | - | 192 | 384 | |||||||
Lenovo 25m LC-LC OM3 MMF Cable | 00MN517 | ASRB | 48 | 16 | 16 | - | - | 192 | 384 | |||||||
Lenovo 30m LC-LC OM3 MMF Cable | 00MN520 | ASRC | 48 | 16 | 16 | - | - | 192 | 384 | |||||||
OM4 optical cables for 16 Gb FC SWL, 32 Gb FC SWL, 40 Gb SR4 FCoE BiDi, and 1/10 GbE SFP+ transceivers | ||||||||||||||||
Lenovo 0.5m LC-LC OM4 MMF Cable | 4Z57A10845 | B2P9 | 48 | 16 | 16 | - | - | 192 | 384 | |||||||
Lenovo 1m LC-LC OM4 MMF Cable | 4Z57A10846 | B2PA | 48 | 16 | 16 | - | - | 192 | 384 | |||||||
Lenovo 3m LC-LC OM4 MMF Cable | 4Z57A10847 | B2PB | 48 | 16 | 16 | - | - | 192 | 384 | |||||||
Lenovo 5m LC-LC OM4 MMF Cable | 4Z57A10848 | B2PC | 48 | 16 | 16 | - | - | 192 | 384 | |||||||
Lenovo 10m LC-LC OM4 MMF Cable | 4Z57A10849 | B2PD | 48 | 16 | 16 | - | - | 192 | 384 | |||||||
Lenovo 15m LC-LC OM4 MMF Cable | 4Z57A10850 | B2PE | 48 | 16 | 16 | - | - | 192 | 384 | |||||||
Lenovo 25m LC-LC OM4 MMF Cable | 4Z57A10851 | B2PF | 48 | 16 | 16 | - | - | 192 | 384 | |||||||
Lenovo 30m LC-LC OM4 MMF Cable | 4Z57A10852 | B2PG | 48 | 16 | 16 | - | - | 192 | 384 | |||||||
UTP Category 6 cables (Green) for 1 GbE RJ-45 SFP transceivers and management ports | ||||||||||||||||
0.75m CAT6 Green Cable | 00WE123 | AVFW | - | - | 16 | 2 | 2 | 68 | 68 | |||||||
1.0m CAT6 Green Cable | 00WE127 | AVFX | - | - | 16 | 2 | 2 | 68 | 68 | |||||||
1.25m CAT6 Green Cable | 00WE131 | AVFY | - | - | 16 | 2 | 2 | 68 | 68 | |||||||
1.5m CAT6 Green Cable | 00WE135 | AVFZ | - | - | 16 | 2 | 2 | 68 | 68 | |||||||
3m CAT6 Green Cable | 00WE139 | AVG0 | - | - | 16 | 2 | 2 | 68 | 68 | |||||||
10m CAT6 Green Cable | 90Y3718 | A1MT | - | - | 16 | 2 | 2 | 68 | 68 | |||||||
25m CAT6 Green Cable | 90Y3727 | A1MW | - | - | 16 | 2 | 2 | 68 | 68 | |||||||
UTP Category 6 cables (Blue) for 1 GbE RJ-45 SFP transceivers and management ports | ||||||||||||||||
0.6m Blue Cat5e Cable | 40K5679 | 3801 | - | - | 16 | 2 | 2 | 68 | 68 | |||||||
1.5m Blue Cat5e Cable | 40K8785 | 3802 | - | - | 16 | 2 | 2 | 68 | 68 | |||||||
3m Blue Cat5e Cable | 40K5581 | 3803 | - | - | 16 | 2 | 2 | 68 | 68 | |||||||
10m Blue Cat5e Cable | 40K8927 | 3804 | - | - | 16 | 2 | 2 | 68 | 68 | |||||||
25m Blue Cat5e Cable | 40K8930 | 3805 | - | - | 16 | 2 | 2 | 68 | 68 |
The following table lists the cabling requirements for the directors.
Transceiver | Standard | Cable | Connector |
---|---|---|---|
128 Gb (4x 32 Gb) Fibre Channel | |||
128 Gb (4x 32 Gb) FC SWL QSFP+ v2 (4M27A08820) | FC-PI-6 |
Up to 30 m with MPO-MPO MMF cables or up to 5 m with MPO-4xLC MMF breakout cables supplied by Lenovo (see Table 4). 850 nm 50 µ MPO-MPO MMF cable:
|
MPO |
128 Gb (4x 32 Gb) FC 2km LWL QSFP+ (4M27A09986) | FC-PI-6 | 32GFC: 1310 nm 9 µ LC-LC SMF cable up to 2 km. | LC |
64 Gb (4x 16 Gb) Fibre Channel | |||
4x 16 Gb FC SWL QSFP+ (01KN805) | FC-PI-5 |
Up to 30 m with MPO-MPO MMF cables or up to 5 m with MPO-4xLC MMF breakout cables supplied by Lenovo (see Table 4). 16GFC: 850 nm 50 µ MPO-MPO MMF cable up to 100 m (OM4) or up to 66 m (OM3). |
MPO |
4x 16 Gb FC LWL QSFP+ (01KN809) | FC-PI-5 | 16GFC: Parallel 1310 nm 9 µ MPO-MPO SMF cables up to 2 km. | MPO |
32 Gb Fibre Channel | |||
32 Gb FC SWL SFP+ (01KN789, 01KN793) | FC-PI-6 |
Up to 30 m with LC-LC MMF cables supplied by Lenovo (see Table 4). 850 nm 50 µ LC-LC MMF cable:
|
LC |
32 Gb FC LWL SFP+ (01KN795, 01KN799) | FC-PI-6 | 32GFC, 16GFC, 8GFC: 1310 nm 9 µ SMF cable up to 10 km. | LC |
16 Gb Fibre Channel | |||
16 Gb FC LWL SFP+ (00MY768) | FC-PI-5 | 1310 nm 9 µ SMF cable:
|
LC |
16 Gb FC SWL SFP+ (88Y6393) | FC-PI-5 |
Up to 30 m with LC-LC MMF cables supplied by Lenovo (see Table 4). 850 nm 50 µ LC-LC MMF cable:
|
LC |
16 Gb FC ELWL SFP+ (00MY770) | FC-PI-5 | 16GFC: 1310 nm 9 µ SMF cable up to 25 km. | LC |
10 Gb Fibre Channel | |||
10 Gb FC SWL SFP+ (00YH933) | FC-10GFC | 10GFC: 850 nm 50 µ LC-LC MMF cable up to 550 m (OM4) or up to 300 m (OM3). | LC |
10 Gb FC LWL SFP+ (00YH929) | FC-10GFC | 10GFC: 1310 nm 9 µ SMF cable up to 10 km. | LC |
100 Gb (4x 25 Gb) Fibre Channel over Ethernet | |||
100Gb (4x25Gb) SR4 QSFP28 (4M27A09989) | 100GBASE-SR4 |
Up to 5 m with MPO-4xLC MMF breakout cables supplied by Lenovo (see Table 4). 850 nm 50 µ MPO-4xLC MMF breakout cable up to 70 m (OM3) or up to 100 m (OM4). |
MPO |
40 Gb Fibre Channel over Ethernet | |||
40Gb (4x10Gb) SR4 QSFP+ (4M27A09987) | 40GBASE-SR4 |
Up to 30 m with MPO-MPO MMF cables or up to 5 m with MPO-4xLC MMF breakout cables supplied by Lenovo (see Table 4). 850 nm 50 µ MPO-MPO MMF cable or MPO-4xLC MMF breakout cable up to 100 m (OM3) or up to 150 m (OM4). |
MPO |
40Gb SR QSFP+ BiDi (4M27A09988) | 40GBASE-SR BiDi |
Up to 30 m with LC-LC MMF cables supplied by Lenovo (see Table 4). 850 nm 50 µ LC-LC MMF cable up to 100 m (OM3) or up to 150 m (OM4). |
LC |
40 Gb Ethernet | |||
40 GbE SR4 QSFP+ (01KN813) | 40GBASE-SR4 |
Up to 30 m with MPO-MPO MMF cables or up to 5 m with MPO-4xLC MMF breakout cables supplied by Lenovo (see Table 4). 850 nm 50 µ MPO-MPO MMF cable or MPO-4xLC MMF breakout cable up to 100 m (OM3) or up to 150 m (OM4). |
MPO |
40 GbE LR4 QSFP+ (01KN817) | 40GBASE-LR4 | 1310 nm 9 µ SMF cable up to 10 km. | LC |
40 GbE ER4 QSFP+ (01KN821) | 40GBASE-ER4 | 1310 nm 9 µ SMF cable up to 40 km. | LC |
10 Gb Ethernet | |||
10 GbE SR SFP+ (49Y4216) | 10GBASE-SR |
Up to 30 m with LC-LC MMF cables supplied by Lenovo (see Table 4). 850 nm 50 µ LC-LC MMF cable up to 400 m (OM4) or up to 300 m (OM3). |
LC |
10 GbE LR SFP+ (95Y0540) | 10GBASE-LR | 1310 nm 9 µ SMF cable up to 10 km. | LC |
10 GbE DWDM SFP+ (01KN837) | 10GBASE-ZRD | 1550 nm 9 µ SMF cable up to 80 km. | LC |
1 Gb Ethernet | |||
1 GbE SX SFP (01KN825) | 1000BASE-SX |
Up to 30 m with LC-LC MMF cables supplied by Lenovo (see Table 4). 850 nm 50 µ LC-LC MMF cable up to 550 m. |
LC |
1 GbE LX SFP (01KN829) | 1000BASE-LX | 1310 nm 9 µ SMF cable up to 10 km. | LC |
1 GbE RJ-45 SFP (01KN833) | 1000BASE-T | UTP Category 5, 5E, or 6 up to 100 meters. | RJ-45 |
Management ports | |||
10/100/1000 Mb Ethernet port | 1000BASE-T |
Up to 25 m with UTP cables supplied by Lenovo (see Table 4). UTP Category 5, 5E, or 6 up to 100 meters. |
RJ-45 |
Serial port | RS-232 | DB-9/RJ-45-to-RJ-45 console cable (comes with the director). | RJ-45 |
Firmware
For details on the latest features supported with the DB400D & DB800D FC SAN Directors, see the Administration Guide for the latest available Fabric OS version 9.0 and above:
https://www.broadcom.com/products/fibre-channel-networking/software/fabric-operating-system
The following optional features are available for the Lenovo FC SAN Directors:
- UltraScale Inter-Chassis Link (ICL): Allows to interconnect up to 9 (full-mesh) or 12 (core-edge) ThinkSystem DB400D or DB800D, or a combination of both, or connect ThinkSystem DB400D or DB800D to Brocade DCX 8510 Backbones by using the QSFP+ ports on the core routing blades.
- Integrated Routing: The FC-FC routing service provides Fibre Channel routing between two or more fabrics without merging those fabrics.
The following table lists ordering information for the optional features and bundles for the DB400D and DB800D 32Gb FC SAN Directors Models HC1.
Description | Part number | Feature code | Maximum quantity supported |
---|---|---|---|
Paper authorization licenses for ThinkSystem DB400D and DB800D | |||
Lenovo DB400D/DB800D S/W, Integrated Routing | 01KN889 | AVH3 | 1 |
License and transceiver bundles for ThinkSystem DB400D | |||
Gen 6 ICL SW License + 8x (4x32Gbps) v2 QSFPs for DB400D | 4M27A08822 | B147 | 2 |
Gen 5 ICL SW License + 8x (4x16Gb) 2km QSFPs for DB400D | 01KN871 | AVKA | 2 |
License and transceiver bundles for ThinkSystem DB800D | |||
Gen 6 ICL SW License + 16x (4x32Gbps) v2 QSFPs for DB800D | 4M27A08821 | B146 | 2 |
Gen 5 ICL SW License + 8x (4x16Gb) 2km QSFPs for DB800D | 01KN859 | AVH0 | 2 |
The following table lists ordering information for the optional features and bundles for the DB400D and DB800D 32Gb FC SAN Directors Models HC1 and HC2.
Description | Part number | Feature code | Maximum quantity supported |
---|---|---|---|
Electronic authorization bundles and licenses for ThinkSystem DB400D and DB800D | |||
Lenovo DB400D/DB800D Integrated Routing | 7S0C000KWW | B3EK | 1 |
License and transceiver bundles for ThinkSystem DB400D | |||
Gen 6 ICL SW 8-port License + 8x (4x32Gbps) QSFPs V2 for DB400D | 4M27A14149 | B5AC | 2 |
Gen 6 ICL SW 8-port License + 8x (4x32Gbps) 2km QSFP for DB400D | 4M27A14152 | B5AF | 2 |
Gen 5 ICL SW 8-port License + 8x (4x16Gbps) 2km QSFPs for DB400D | 4M27A14150 | B5AD | 2 |
License and transceiver bundles for ThinkSystem DB800D | |||
Gen 6 ICL 16-port License + 16x (4x32Gbps) QSFPs V2 for DB800D | 4M27A14148 | B5AB | 2 |
Gen 6 ICL SW 16-port License + 8x (4x32Gbps) 2km QSFP for DB800D | 4M27A14151 | B5AE | 2 |
Gen 5 ICL 16-port License + 8x (4x16Gbps) 2km QSFPs for DB800D | 4M27A14147 | B5AA | 2 |
Each Inter-Chassis Link (ICL) bundle includes Port on Demand (POD) licenses to activate a half of available QSFP+ ports on both CR blades in the chassis, that is, each ICL license activates four ports on each CR32-4 blade in the DB400D chassis and eight ports on each CR32-8 blade in the DB800D chassis.
Each ICL bundle also includes 8 (the DB400D bundles and the DB800D 2km QSFPs bundle) or 16 (the DB800D bundles excluding the 2km QSFPs bundles) QSFP+ transceivers to populate the activated ports.
The firmware entitlement is included in the warranty service upgrades for DB400D Model HC2 and DB800D Model HC2.
The Integrated Routing feature (7S0C000KWW) comes with its own 1-year firmware support entitlement. The options to extend entitlement for additional years of firmware support for the Integrated Routing feature are listed in the following table.
Description | Part number | Feature code |
---|---|---|
Lenovo DB400D/DB800D Integrated Routing Support Extension, 2-Years | 7S0C000SWW | S0FA |
Lenovo DB400D/DB800D Integrated Routing Support Extension, 4-Years | 7S0C000ZWW | S0FH |
Management software
Lenovo offers optional Brocade SANnav™ Management Portal and SANnav Global View software license subscriptions that provide comprehensive visibility into the SAN environment, allow administrators to quickly identify, isolate, and correct problems, and accelerate administrative tasks by simplifying and automating workflows.
SANnav Management Portal is a next-generation SAN management application with a simple browser-based user interface (UI) and with a focus on streamlining common workflows, such as configuration, zoning, deployment, monitoring, troubleshooting, reporting, and analytics.
Lenovo offers the following SANnav Management Portal subscriptions:
- SANnav Management Portal Base: Designed for mid-sized SANs to manage up to 600 SAN switch ports only (SAN director ports can only be managed with the Enterprise edition).
- SANnav Management Portal Enterprise: Designed for enterprise-class SANs to manage up to 15 000 SAN switch and director ports.
SANnav Management Portal supports all Brocade SAN switches and platforms that run the Fabric OS® version 7.4 or above, including Lenovo B300, B6505, B6510, DB610S, DB620S, DB400D, DB720S, DB730S, DB800D, Brocade Directors, and FC5022.
With SANnav Global View, administrators can quickly visualize the health, performance, and inventory of multiple SANnav Management Portal instances using a simple, intelligent dashboard and can easily navigate from a global view down to local environments to investigate points of interest. SANnav Global View is designed to manage up to 20 SANnav Management Portal instances.
For more information, refer to the SANnav Management Portal documentation:
http://www.broadcom.com/products/fibre-channel-networking/software/sannav-management-portal#documentation
The following table lists ordering information for the optional SANnav Management Portal and SANnav Global View management tools. After a client has an active SANnav license, Lenovo offers a “license extension/renewal”. This offering provides our clients the flexible to extend their subscription down to a specific end date. This allows clients the ability to align to your company’s budget or align with warranty of your FC SAN switches/directors. Please engage directly with your Lenovo sales representative for more details.
Part number | Feature code | Description |
---|---|---|
SANnav Management Portal electronic authorization licenses | ||
7S0C0010WW | S1K6 | Brocade SANnav Mgmt Portal Base Edition - 1YR License 600 ports |
7S0C0013WW | S1K8 | Brocade SANnav Mgmt Portal Base Edition - 3YR License 600 ports |
7S0C001KWW | S4MB | Brocade SANnav Mgmt Portal Base Edition - 5YR License 600 ports |
7S0C0011WW | S1K7 | Brocade SANnav Mgmt Portal Enterprise Edition - 1YR License 15K ports |
7S0C0014WW | S1K9 | Brocade SANnav Mgmt Portal Enterprise Edition - 3YR License 15K ports |
7S0C001LWW | S4MC | Brocade SANnav Mgmt Portal Enterprise Edition - 5YR License 15K ports |
SANnav Global View electronic authorization licenses | ||
7S0C0012WW | S1D8 | Brocade SANnav Global View - 1YR License |
7S0C0015WW | S1D9 | Brocade SANnav Global View - 3YR License |
7S0C001JWW | S4MA | Brocade SANnav Global View - 5YR License |
The SANnav licenses are subscription-based with 1-year, 3-year, or 5-year software entitlement and support.
Fibre Channel standards
The SAN Directors supports the standards listed at the following web page:
https://www.broadcom.com/support/fibre-channel-networking/san-standards/standards-compliance
Ethernet standards
The DB400D and DB800D 32Gb FC SAN Directors support the following Ethernet standards:
- IEEE 802.1AB Data Center Bridging Capability Exchange Protocol (DCBX)
- IEEE 802.1p Class of Service (CoS) prioritization
- IEEE 802.1Q VLAN Tagging
- IEEE 802.1Qbb Priority-Based Flow Control (PFC)
- IEEE 802.1Qaz Enhanced Transmission Selection (ETS)
- IEEE 802.3 10BASE-T Ethernet (CP management interfaces)
- IEEE 802.3u 100BASE-TX Fast Ethernet (CP management interfaces)
- IEEE 802.3z 1000BASE-SX short range fiber optics Gigabit Ethernet
- IEEE 802.3z 1000BASE-LX long range fiber optics Gigabit Ethernet
- IEEE 802.3ab 1000BASE-T copper twisted pair Gigabit Ethernet
- IEEE 802.3ae 10GBASE-SR short range fiber optics 10 Gb Ethernet
- IEEE 802.3ae 10GBASE-LR long range fiber optics 10 Gb Ethernet
- IEEE 802.3ba 40GBASE-SR4 short range fiber optics 40 Gb Ethernet
- IEEE 802.3ba 40GBASE-LR4 long range fiber optics 40 Gb Ethernet
- IEEE 802.3bm 40GBASE-ER4 extended range fiber optics 40 Gb Ethernet
- IEEE 802.3bm 100GBASE-SR4 short range fiber optics 100 Gb Ethernet
- 10GBASE-ZRD DWDM fiber optics 10 Gb Ethernet
Cooling
The DB400D and DB800D 32Gb FC SAN Directors ship without cooling modules (fan assemblies); the cooling modules must be ordered together with the ThinkSystem DB400D and DB800D. Each cooling module has two integrated fans that provide non-port side air intake.
Two cooling modules are required for the ThinkSystem DB400D, and three cooling modules are required for the ThinkSystem DB800D. Cooling modules provide N + 1 fan redundancy (3 + 1 for the DB400D; 5 + 1 for the DB800D), and the device can continue operation while one fan assembly is replaced if the fan assembly is replaced immediately.
The following table lists the cooling modules for the DB400D and DB800D 32Gb FC SAN Directors.
Description | Part number | Feature code | Quantity | |
---|---|---|---|---|
DB400D | DB800D | |||
FC SAN Director Fan Tray (Non-port side Intake for DB400D/DB800D) | 01KN895 | AVGY | 2 | 3 |
Power supplies and cables
The DB400D and DB800D 32Gb FC SAN Directors ship without power supplies; at least a minimum required quantity of the power supplies must be ordered together with the ThinkSystem DB400D and DB800D. Two power supplies are required for the ThinkSystem DB400D, and a minimum of three power supplies is required for the ThinkSystem DB800D. The forth power supply can be added to the ThinkSystem DB800D to provide additional power redundancy in certain configurations.
The power supplies are hot-swap 1450 W (100 - 120 V AC) / 2870 W (200 - 240 V AC), and each power supply has an IEC 320-C20 connector. Each power supply has two integrated fans that provide non-port side air intake that matches the airflow of the cooling modules.
The following table lists the power supplies for the DB400D and DB800D 32Gb FC SAN Directors.
Description | Part number | Feature code | Quantity (min / max) | |
---|---|---|---|---|
DB400D | DB800D | |||
FC SAN Director PSU (Non-port side Intake for DB400D/DB800D) | 01KN892 | AVGX | 2 / 2 | 3 / 4* |
FC SAN Director PSU (Non-Port Side Intake for DB400D/DB800D) | 4M27A36850 | BBCU | 2 / 2 | 3 / 4* |
* In most scenarios, it is recommended to have 4 power supplies installed in the DB800D due to typical dual-PDU configurations with redundant power sources.
The power supply redundancy depends on the blade and port configuration and the AC input voltage level, as shown in the following table.
Model | Power supply quantity |
Configured ports | Redundancy | |
---|---|---|---|---|
100 - 120 V AC | 200 - 240 V AC | |||
DB400D | 2 | Any combination of ports and QSFP ICLs | No | N + N |
DB800D | 3 | 144x 32 Gbps ports and QSFP ICLs | N+1 | N + 2 |
Any other combination of ports and QSFP ICLs | No | N + 1 | ||
4 | 144x 32 Gbps ports and QSFP ICLs | N+N | N + 3 | |
Any other combination of ports and QSFP ICLs | No | N + N |
The FC SAN directors come standard without power cords; up to four rack power cables or line cords should be ordered for the FC SAN Directors depending on the quantity of power supplies.
The following table lists power cords for the DB400D and DB800D 32Gb FC SAN Directors.
Description | Part number | Feature code |
---|---|---|
Rack power cables | ||
2.5m, 16A/125-250V, C19 to IEC 320-C20 Rack Power Cable | 39Y7916 | 6252 |
Line cords | ||
Argentina 4.3m, 16A/250V, C19 to IRAM 2073 Line Cord | 40K9777 | 6276 |
Brazil 4.3m, 16A/250V, C19 to NBR 14136 Line Cord | 40K9775 | 6277 |
China 4.3m, 16A/250V, C19 to GB2099.1 Line Cord | 40K9774 | 6288 |
India 4.3m, 16A/250V, C19 to IS6538 Line Cord | 40K9776 | 6285 |
Israel 4.3m, 16A/250V, C19 to SI 32 Line Cord | 40K9771 | 6282 |
Italy 4.3m, 16A/250V, C19 to CEI 23-16 Line Cord | 40K9768 | 6281 |
Japan 4.3m, 15A/100V, C19 to JIS C-8303 Line Cord | 41Y9232 | 6290 |
Japan 4.3m, 15A/200V, C19 to JIS C-8303 Line Cord | 41Y9233 | 6291 |
Korea 4.3m, 15A/250V, C19 to KSC 8305 Line Cord | 41Y9231 | 6289 |
South Africa 4.3m, 16A/250V, C19 to SABS 164 Line Cord | 40K9770 | 6280 |
Switzerland 4.3m, 16A/250V, C19 to SEV 1011 Line Cord | 81Y2391 | 6549 |
Taiwan 4.3m, 16A/125V, C19 to CNS 10917-3 Line Cord | 41Y9229 | 6286 |
Taiwan 4.3m, 16A/250V, C19 to CNS 10917-3 Line Cord | 41Y9230 | 6287 |
United Kingdom 4.3m, 13A/250V, C19 to BS 1363/A Line Cord | 40K9767 | 6278 |
United States 4.3m, 15A/125V, C19 to NEMA 5-15P Line Cord | 4L67A08372 | B0RV |
United States 4.3m, 15A/250V, C19 to NEMA 6-15P Line Cord | 00D7197 | A1NV |
Rack installation
The DB400D and DB800D 32Gb FC SAN Directors come standard with the adjustable 27" to 31" rack mount kits that can be used for 4-post rack installations. The ThinkSystem DB400D also supports the optional Airflow Diversion Kits that allow to divert the airflow from the side air vent to the port side. In addition, the Lenovo DB800D supports 22" rack mount kit for specific racks.
If required, the Lenovo FC SAN Directors can be mounted in a 2-post rack cabinet by using the optional mid-mount rack kits.
The following table lists rack-mount options for the DB400D and DB800D 32Gb FC SAN Directors.
Description | Part number | Feature code | Maximum quantity supported |
---|---|---|---|
ThinkSystem DB400D rack-mount options | |||
Lenovo DB400D mid-mount rack kit | 01KN874 | AVKB | 1 |
27-31" Airflow Diversion Kit for Lenovo DB400D | 01KN877 | AVKC | 1* |
18-24" Airflow Diversion Kit for Lenovo DB400D | 01KN880 | AVKD | 1* |
ThinkSystem DB800D rack-mount options | |||
Lenovo DB800D 22" rack mount kit | 01KN883 | AVH1 | 1 |
Lenovo DB800D mid-mount rack kit | 01KN886 | AVH2 | 1 |
* 27-31" and 18-24" Airflow Diversion Kits are mutually exclusive. Only one of these kits should be ordered, depending on the depth of the rack cabinet.
The optional airflow diversion kit for the DB400D 32Gb FC Director is shown in the following figure.
Figure 9. DB400D Airflow Diversion Kit
The optional mid-mount rack kits for the DB400D and DB800D 32Gb FC SAN Directors are shown in the following figure.
Figure 10. ThinkSystem DB400D (Left) and DB800D (Right) Mid-mount Rack Kits
In addition, in order for the DB400D and DB800D 32Gb FC SAN Directors to meet FIPS 140-2 Level 2 Physical Security requirements the tamper-evident seals must be installed (see the following table for ordering information).
Description | Part number | Feature code | Maximum quantity supported |
---|---|---|---|
Brocade FIPS 140-2 High Security Labels and Seals | 01KN785 | AVGB | 1 |
Physical specifications
The DB400D and DB800D 32Gb FC SAN Directors have the following dimensions and weight (approximate):
- Height:
- DB400D: 345 mm (13.6 in.)
- DB800D: 612 mm (24.1 in.)
- Width: 437 mm (17.2 in.)
- Depth: 611 mm (24.0 in.)
- Weight:
- DB400D:
- Empty: 24.5 kg (54.0 lb)
- Fully configured: 69.0 kg (152.0 lb)
- DB800D:
- Empty: 35.6 kg (78.5 lb)
- Fully configured: 145.8 kg (321.5 lb)
- DB400D:
Operating environment
The DB400D and DB800D 32Gb FC SAN Directors are supported in the following environment:
- Air temperature:
- Operating: 0°C to 40°C (32°F to 104°F)
- Non-operating: -25°C to +70°C (-13°F to 158°F)
- Maximum altitude:
- Operating: 3,000 m (9,842 ft)
- Non-operating: 12,000 m (39,370 ft)
- Humidity:
- Operating: 5% to 93% non-condensing with 10% per hour maximum rate of change
- Non-operating: 10% to 93% non-condensing
- Electrical power:
- Voltage range: 100 V AC - 240 V AC (nominal)
- Frequency: 50 Hz / 60 Hz (nominal)
- Power consumption:
- DB400D:
- Idle: 840 watts
- Typical: 1407 watts (FC32-48) / 1548 watts (FC32-64)
- Maximum: 2438 watts (FC32-48) / 2953 watts (FC32-64)
- DB800D:
- Idle: 1515 watts
- Typical: 2647 watts (FC32-48) / 2933 watts (FC32-64)
- Maximum: 4339 watts (FC32-48) / 5380 watts (FC32-64)
- DB400D:
- Heat dissipation:
- DB400D:
- Idle: 2867 BTU per hour
- Typical: 4802 BTU per hour (FC32-48) / 5283 BTU per hour (FC32-64)
- Maximum: 8322 BTU per hour (FC32-48) / 10049 BTU per hour (FC32-64)
- DB800D:
- Idle: 5171 BTU per hour
- Typical: 9034 BTU per hour (FC32-48) / 10010 BTU per hour (FC32-64)
- Maximum: 14810 BTU per hour (FC32-48) / 18362 BTU per hour (FC32-64)
- DB400D:
- Acoustical noise emission:
- DB400D: 64.2 dB
- DB800D: 68.2 dB
Warranty upgrades and post-warranty support
The DB400D and DB800D 32Gb FC SAN Directors have a one-year warranty.
Our global network of regional support centers offers consistent, local-language support enabling you to vary response times and level of service to match the criticality of your support needs:
- Standard Next Business Day – Best choice for non-essential systems requiring simple maintenance.
- Premier Next Business Day – Best choice for essential systems requiring technical expertise from senior-level Lenovo engineers.
- Premier 24x7 4-Hour Response – Best choice for systems where maximum uptime is critical.
- Premier Enhanced Storage Support 24x7 4-Hour Response – Best choice for storage systems where maximum uptime is critical.
For more information, consult the brochure Lenovo Operational Support Services for Data Centers Services.
Services
Lenovo Data Center Services empower you at every stage of your IT lifecycle. From expert advisory and strategic planning to seamless deployment and ongoing support, we ensure your infrastructure is built for success. Our comprehensive services accelerate time to value, minimize downtime, and free your IT staff to focus on driving innovation and business growth.
Note: Some service options may not be available in all markets or regions. For more information, go to https://lenovolocator.com/. For information about Lenovo service upgrade offerings that are available in your region, contact your local Lenovo sales representative or business partner.
In this section:
- Lenovo Advisory Services
- Lenovo Plan & Design Services
- Lenovo Deployment, Migration, and Configuration Services
- Lenovo Support Services
- Lenovo Managed Services
- Lenovo Sustainability Services
Lenovo Advisory Services
Lenovo Advisory Services simplify the planning process, enabling customers to build future-proofed strategies in as little as six weeks. Consultants provide guidance on projects including VM migration, storage, backup and recovery, and cost management to accelerate time to value, improve cost efficiency, and build a flexibly scalable foundation.
- Assessment Services
An Assessment helps solve your IT challenges through an onsite, multi-day session with a Lenovo technology expert. We perform a tools-based assessment which provides a comprehensive and thorough review of a company's environment and technology systems. In addition to the technology based functional requirements, the consultant also discusses and records the non-functional business requirements, challenges, and constraints. Assessments help organizations like yours, no matter how large or small, get a better return on your IT investment and overcome challenges in the ever-changing technology landscape.
- Design Services
Professional Services consultants perform infrastructure design and implementation planning to support your strategy. The high-level architectures provided by the assessment service are turned into low level designs and wiring diagrams, which are reviewed and approved prior to implementation. The implementation plan will demonstrate an outcome-based proposal to provide business capabilities through infrastructure with a risk-mitigated project plan.
Lenovo Plan & Design Services
Unlock faster time to market with our tailored, strategic design workshops to align solution approaches with your business goals and technical requirements. Leverage our deep solution expertise and end-to-end delivery partnership to meet your goals efficiently and effectively.
Lenovo Deployment, Migration, and Configuration Services
Optimize your IT operations by shifting labor-intensive functions to Lenovo's skilled technicians for seamless on-site or remote deployment, configuration, and migration. Enjoy peace of mind, faster time to value, and comprehensive knowledge sharing with your IT staff, backed by our best-practice methodology.
- Deployment Services for Storage and ThinkAgile
A comprehensive range of remote and onsite options tailored specifically for your business needs to ensure your storage and ThinkAgile hardware are fully operational from the start.
- Hardware Installation Services
A full-range, comprehensive setup for your hardware, including unpacking, inspecting, and positioning components to ensure your equipment is operational and error-free for the most seamless and efficient installation experience, so you can quickly benefit from your investments.
- DM/DG File Migration Services
Take the burden of file migration from your IT’s shoulders. Our experts will align your requirements and business objectives to the migration plans while coordinating with your team to plan and safely execute the data migration to your storage platforms.
- DM/DG/DE Health Check Services
Our experts perform proactive checks of your Firmware and system health to ensure your machines are operating at peak and optimal efficiency to maximize up-time, avoid system failures, ensure the security of IT solutions and simplify maintenance.
- Factory Integrated Services
A suite of value-added offerings provided during the manufacturing phase of a server or storage system that reduces time to value. These services aim at improving your hardware deployment experience and enhance the quality of a standard configuration before it arrives at your facility.
Lenovo Support Services
In addition to response time options for hardware parts, repairs, and labor, Lenovo offers a wide array of additional support services to ensure your business is positioned for success and longevity. Our goal is to reduce your capital outlays, mitigate your IT risks, and accelerate your time to productivity.
- Premier Support for Data Centers
Your direct line to the solution that promises the best, most comprehensive level of support to help you fully unlock the potential of your data center.
- Premier Enhanced Storage Support (PESS)
Gain all the benefits of Premier Support for Data Centers, adding dedicated storage specialists and resources to elevate your storage support experience to the next level.
- Committed Service Repair (CSR)
Our commitment to ensuring the fastest, most seamless resolution times for mission-critical systems that require immediate attention to ensure minimal downtime and risk for your business. This service is only available for machines under the Premier 4-Hour Response SLA.
- Multivendor Support Services (MVS)
Your single point of accountability for resolution support across vast range of leading Server, Storage, and Networking OEMs, allowing you to manage all your supported infrastructure devices seamlessly from a single source.
- Keep Your Drive (KYD)
Protect sensitive data and maintain compliance with corporate retention and disposal policies to ensure your data is always under your control, regardless of the number of drives that are installed in your Lenovo server.
- Technical Account Manager (TAM)
Your single point of contact to expedite service requests, provide status updates, and furnish reports to track incidents over time, ensuring smooth operations and optimized performance as your business grows.
- Enterprise Software Support (ESS)
Gain comprehensive, single-source, and global support for a wide range of server operating systems and Microsoft server applications.
For more information, consult the brochure Lenovo Operational Support Services for Data Centers.
Lenovo Managed Services
Achieve peak efficiency, high security, and minimal disruption with Lenovo's always-on Managed Services. Our real-time monitoring, 24x7 incident response, and problem resolution ensure your infrastructure operates seamlessly. With quarterly health checks for ongoing optimization and innovation, Lenovo's remote active monitoring boosts end-user experience and productivity by keeping your data center's hardware performing at its best.
Lenovo Managed Services provides continuous 24x7 remote monitoring (plus 24x7 call center availability) and proactive management of your data center using state-of-the-art tools, systems, and practices by a team of highly skilled and experienced Lenovo services professionals.
Quarterly reviews check error logs, verify firmware & OS device driver levels, and software as needed. We’ll also maintain records of latest patches, critical updates, and firmware levels, to ensure you systems are providing business value through optimized performance.
Lenovo Sustainability Services
- Asset Recovery Services
Lenovo Asset Recovery Services (ARS) provides a secure, seamless solution for managing end-of-life IT assets, ensuring data is safely sanitized while contributing to a more circular IT lifecycle. By maximizing the reuse or responsible recycling of devices, ARS helps businesses meet sustainability goals while recovering potential value from their retired equipment. For more information, see the Asset Recovery Services offering page.
- CO2 Offset Services
Lenovo’s CO2 Offset Services offer a simple and transparent way for businesses to take tangible action on their IT footprint. By integrating CO2 offsets directly into device purchases, customers can easily support verified climate projects and track their contributions, making meaningful progress toward their sustainability goals without added complexity.
- Lenovo Certified Refurbished
Lenovo Certified Refurbished offers a cost-effective way to support IT circularity without compromising on quality and performance. Each device undergoes rigorous testing and certification, ensuring reliable performance and extending its lifecycle. With Lenovo’s trusted certification, you gain peace of mind while making a more sustainable IT choice.
Lenovo TruScale
Lenovo TruScale XaaS is your set of flexible IT services that makes everything easier. Streamline IT procurement, simplify infrastructure and device management, and pay only for what you use – so your business is free to grow and go anywhere.
Lenovo TruScale is the unified solution that gives you simplified access to:
- The industry’s broadest portfolio – from pocket to cloud – all delivered as a service
- A single-contract framework for full visibility and accountability
- The global scale to rapidly and securely build teams from anywhere
- Flexible fixed and metered pay-as-you-go models with minimal upfront cost
- The growth-driving combination of hardware, software, infrastructure, and solutions – all from one single provider with one point of accountability.
For information about Lenovo TruScale offerings that are available in your region, contact your local Lenovo sales representative or business partner.
Regulatory compliance
The DB400D and DB800D 32Gb FC SAN Directors conform to the following regulations:
- Electromagnetic compatibility
- FCC Part 15, Subpart B (Class A)
- EN 55022 (CE mark) (Class A)
- EN 55024 (CE mark)
- ICES-003 (Canada) (Class A)
- AS/NZ 55022 (Australia) (Class A)
- VCCI (Japan) (Class A)
- EN 61000-3-2
- EN 61000-3-3
- EN 61000-6-1
- Safety
- UL/CSA 60950
- EN 60950
- IEC 60950
- Environmental: EU RoHS
Interoperability
For end-to-end storage configuration support, refer to the Lenovo Storage Interoperation Center (LSIC):
https://datacentersupport.lenovo.com/us/en/lsic
Use the LSIC to select the known components of your configuration and then get a list all other supported combinations, with details about supported hardware, firmware, operating systems, and drivers, plus any additional configuration notes. View results on screen or export them to Excel.
External storage systems
Lenovo offers the ThinkSystem DE Series and ThinkSystem DM Series external storage systems for high-performance storage. See the DE Series and DM Series product guides for specific controller models, expansion enclosures and configuration options:
- ThinkSystem DE Series Storage
https://lenovopress.com/storage/thinksystem/de-series#rt=product-guide - ThinkSystem DM Series Storage
https://lenovopress.com/storage/thinksystem/dm-series#rt=product-guide - ThinkSystem DG Series Storage
https://lenovopress.com/storage/thinksystem/dg-series#rt=product-guide
External backup units
The following table lists the external backup options that are offered by Lenovo that can be used in Lenovo FC SAN solutions.
Note: Information provided in this section is for ordering reference purposes only. End-to-end LTO Ultrium configuration support for a particular tape backup unit must be verified through the System Storage Interoperation Center (SSIC):
http://www.ibm.com/systems/support/storage/ssic
Part number | Description |
---|---|
External tape backup libraries | |
6741A1F | IBM TS4300 3U Tape Library-Base Unit |
Fibre Channel backup drives for TS4300 Tape Library - Full Height | |
01KP935 | LTO 6 FH Fibre Channel Drive |
01KP938 | LTO 7 FH Fibre Channel Drive |
01KP954 | LTO 8 FH Fibre Channel Drive |
02JH837 | LTO 9 FH Fibre Channel Drive |
Fibre Channel backup drives for TS4300 Tape Library - Half Height | |
01KP933 | LTO 6 HH Fibre Channel Drive |
01KP936 | LTO 7 HH Fibre Channel Drive |
01KP952 | LTO 8 HH Fibre Channel Drive |
02JH835 | LTO 9 HH Fibre Channel Drive |
For more information, see the list of Product Guides in the Tape Autoloaders and Libraries category:
https://lenovopress.com/storage/tape/library
Rack cabinets
The following table lists the supported rack cabinets.
Model | Description |
---|---|
7D6DA007WW | ThinkSystem 42U Onyx Primary Heavy Duty Rack Cabinet (1200mm) |
7D6DA008WW | ThinkSystem 42U Pearl Primary Heavy Duty Rack Cabinet (1200mm) |
7D6EA009WW | ThinkSystem 48U Onyx Primary Heavy Duty Rack Cabinet (1200mm) |
7D6EA00AWW | ThinkSystem 48U Pearl Primary Heavy Duty Rack Cabinet (1200mm) |
93604PX | 42U 1200mm Deep Dynamic Rack |
93604EX | 42U 1200mm Deep Dynamic Expansion Rack |
93614PX | 42U 1200mm Deep Static Rack |
93614EX | 42U 1200mm Deep Static Expansion Rack |
93634PX | 42U 1100mm Dynamic Rack |
93634EX | 42U 1100mm Dynamic Expansion Rack |
93074RX | 42U Standard Rack (1000mm) |
93084PX | 42U Enterprise Rack |
93084EX | 42U Enterprise Expansion Rack |
For specifications about these racks, see the Lenovo Rack Cabinet Reference, available from:
https://lenovopress.com/lp1287-lenovo-rack-cabinet-reference
For more information, see the list of Product Guides in the Rack cabinets category:
https://lenovopress.com/servers/options/racks
Power distribution units
The following table lists the power distribution units (PDUs) that are offered by Lenovo.
Part number |
Feature code |
Description |
ANZ
|
ASEAN
|
Brazil
|
EET
|
MEA
|
RUCIS
|
WE
|
HTK
|
INDIA
|
JAPAN
|
LA
|
NA
|
PRC
|
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
0U Basic PDUs | |||||||||||||||
4PU7A93176 | C0QH | 0U 36 C13 and 6 C19 Basic 32A 1 Phase PDU v2 | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
4PU7A93169 | C0DA | 0U 36 C13 and 6 C19 Basic 32A 1 Phase PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
4PU7A93177 | C0QJ | 0U 24 C13/C15 and 24 C13/C15/C19 Basic 32A 3 Phase WYE PDU v2 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
4PU7A93170 | C0D9 | 0U 24 C13/C15 and 24 C13/C15/C19 Basic 32A 3 Phase WYE PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
00YJ776 | ATZY | 0U 36 C13/6 C19 24A 1 Phase PDU | N | Y | Y | N | N | N | N | N | N | Y | Y | Y | N |
00YJ779 | ATZX | 0U 21 C13/12 C19 48A 3 Phase PDU | N | N | Y | N | N | N | Y | N | N | Y | Y | Y | N |
00YJ777 | ATZZ | 0U 36 C13/6 C19 32A 1 Phase PDU | Y | Y | N | Y | Y | Y | Y | Y | Y | N | N | Y | Y |
00YJ778 | AU00 | 0U 21 C13/12 C19 32A 3 Phase PDU | Y | Y | N | Y | Y | Y | Y | Y | Y | N | N | Y | Y |
0U Switched and Monitored PDUs | |||||||||||||||
4PU7A93181 | C0QN | 0U 21 C13/C15 and 21 C13/C15/C19 Switched and Monitored 48A 3 Phase Delta PDU v2 (60A derated) | N | Y | N | N | N | N | N | Y | N | Y | N | Y | N |
4PU7A93174 | C0D5 | 0U 21 C13/C15 and 21 C13/C15/C19 Switched and Monitored 48A 3 Phase Delta PDU (60A derated) | N | Y | N | Y | N | N | Y | Y | N | N | N | Y | N |
4PU7A93178 | C0QK | 0U 20 C13 and 4 C19 Switched and Monitored 32A 1 Phase PDU v2 | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
4PU7A93171 | C0D8 | 0U 20 C13 and 4 C19 Switched and Monitored 32A 1 Phase PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
4PU7A93182 | C0QP | 0U 18 C13/C15 and 18 C13/C15/C19 Switched and Monitored 63A 3 Phase WYE PDU v2 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
4PU7A93175 | C0CS | 0U 18 C13/C15 and 18 C13/C15/C19 Switched and Monitored 63A 3 Phase WYE PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
4PU7A93180 | C0QM | 0U 18 C13/C15 and 18 C13/C15/C19 Switched and Monitored 32A 3 Phase WYE PDU v2 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
4PU7A93173 | C0D6 | 0U 18 C13/C15 and 18 C13/C15/C19 Switched and Monitored 32A 3 Phase WYE PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
4PU7A93179 | C0QL | 0U 16 C13/C15 and 16 C13/C15/C19 Switched and Monitored 24A 1 Phase PDU v2 (30A derated) | N | Y | N | N | N | N | N | Y | N | Y | N | Y | N |
4PU7A93172 | C0D7 | 0U 16 C13/C15 and 16 C13/C15/C19 Switched and Monitored 24A 1 Phase PDU(30A derated) | N | Y | N | Y | N | N | Y | Y | N | N | N | Y | N |
00YJ783 | AU04 | 0U 12 C13/12 C19 Switched and Monitored 48A 3 Phase PDU | N | N | Y | N | N | N | Y | N | N | Y | Y | Y | N |
00YJ781 | AU03 | 0U 20 C13/4 C19 Switched and Monitored 24A 1 Phase PDU | N | N | Y | N | Y | N | Y | N | N | Y | Y | Y | N |
00YJ782 | AU02 | 0U 18 C13/6 C19 Switched and Monitored 32A 3 Phase PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | N | Y |
00YJ780 | AU01 | 0U 20 C13/4 C19 Switched and Monitored 32A 1 Phase PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | N | Y |
1U Switched and Monitored PDUs | |||||||||||||||
4PU7A90808 | C0D4 | 1U 18 C19/C13 Switched and monitored 48A 3P WYE PDU V2 ETL | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
4PU7A81117 | BNDV | 1U 18 C19/C13 switched and monitored 48A 3P WYE PDU - ETL | N | N | N | N | N | N | N | N | N | N | N | Y | N |
4PU7A90809 | C0DE | 1U 18 C19/C13 Switched and monitored 48A 3P WYE PDU V2 CE | N | N | N | N | N | Y | Y | N | N | N | N | N | N |
4PU7A81118 | BNDW | 1U 18 C19/C13 switched and monitored 48A 3P WYE PDU - CE | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | N | Y |
4PU7A90810 | C0DD | 1U 18 C19/C13 Switched and monitored 80A 3P Delta PDU V2 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
4PU7A77467 | BLC4 | 1U 18 C19/C13 Switched and Monitored 80A 3P Delta PDU | N | N | N | N | N | N | N | N | N | Y | N | Y | N |
4PU7A90811 | C0DC | 1U 12 C19/C13 Switched and monitored 32A 3P WYE PDU V2 | N | N | N | N | N | Y | Y | N | N | N | N | N | N |
4PU7A77468 | BLC5 | 1U 12 C19/C13 switched and monitored 32A 3P WYE PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
4PU7A90812 | C0DB | 1U 12 C19/C13 Switched and monitored 60A 3P Delta PDU V2 | N | N | N | N | N | N | N | N | N | Y | N | N | N |
4PU7A77469 | BLC6 | 1U 12 C19/C13 switched and monitored 60A 3P Delta PDU | N | N | N | N | N | N | N | N | N | N | N | Y | N |
46M4002 | 5896 | 1U 9 C19/3 C13 Switched and Monitored DPI PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
46M4004 | 5894 | 1U 12 C13 Switched and Monitored DPI PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
46M4003 | 5897 | 1U 9 C19/3 C13 Switched and Monitored 60A 3 Phase PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
46M4005 | 5895 | 1U 12 C13 Switched and Monitored 60A 3 Phase PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
1U Ultra Density Enterprise PDUs (9x IEC 320 C13 + 3x IEC 320 C19 outlets) | |||||||||||||||
71763NU | 6051 | Ultra Density Enterprise C19/C13 PDU 60A/208V/3PH | N | N | Y | N | N | N | N | N | N | Y | Y | Y | N |
71762NX | 6091 | Ultra Density Enterprise C19/C13 PDU Module | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
1U C13 Enterprise PDUs (12x IEC 320 C13 outlets) | |||||||||||||||
39M2816 | 6030 | DPI C13 Enterprise PDU Plus Module (WW) | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
39Y8941 | 6010 | DPI C13 Enterprise PDU Module (WW) | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
1U C19 Enterprise PDUs (6x IEC 320 C19 outlets) | |||||||||||||||
39Y8948 | 6060 | DPI C19 Enterprise PDU Module (WW) | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
39Y8923 | 6061 | DPI Three-phase 60A/208V C19 Enterprise PDU (US) | N | N | Y | N | N | N | Y | N | N | N | Y | Y | N |
1U Front-end PDUs (3x IEC 320 C19 outlets) | |||||||||||||||
39Y8938 | 6002 | DPI Single-phase 30A/120V Front-end PDU (US) | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
39Y8939 | 6003 | DPI Single-phase 30A/208V Front-end PDU (US) | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
39Y8934 | 6005 | DPI Single-phase 32A/230V Front-end PDU (International) | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
39Y8940 | 6004 | DPI Single-phase 60A/208V Front-end PDU (US) | Y | N | Y | Y | Y | Y | Y | N | N | Y | Y | Y | N |
39Y8935 | 6006 | DPI Single-phase 63A/230V Front-end PDU (International) | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
1U NEMA PDUs (6x NEMA 5-15R outlets) | |||||||||||||||
39Y8905 | 5900 | DPI 100-127V NEMA PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Line cords for 1U PDUs that ship without a line cord | |||||||||||||||
40K9611 | 6504 | 4.3m, 32A/380-415V, EPDU/IEC 309 3P+N+G 3ph wye (non-US) Line Cord | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
40K9612 | 6502 | 4.3m, 32A/230V, EPDU to IEC 309 P+N+G (non-US) Line Cord | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
40K9613 | 6503 | 4.3m, 63A/230V, EPDU to IEC 309 P+N+G (non-US) Line Cord | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
40K9614 | 6500 | 4.3m, 30A/208V, EPDU to NEMA L6-30P (US) Line Cord | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
40K9615 | 6501 | 4.3m, 60A/208V, EPDU to IEC 309 2P+G (US) Line Cord | N | N | Y | N | N | N | Y | N | N | Y | Y | Y | N |
40K9617 | 6505 | 4.3m, 32A/230V, Souriau UTG Female to AS/NZ 3112 (Aus/NZ) Line Cord | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
40K9618 | 6506 | 4.3m, 32A/250V, Souriau UTG Female to KSC 8305 (S. Korea) Line Cord | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
For more information, see the Lenovo Press documents in the PDU category:
https://lenovopress.com/servers/options/pdu
Uninterruptible power supply units
The following table lists the uninterruptible power supply (UPS) units that are offered by Lenovo.
Part number | Description |
---|---|
Rack-mounted or tower UPS units - 100-125VAC | |
7DD5A001WW | RT1.5kVA 2U Rack or Tower UPS-G2 (100-125VAC) |
55941AX | RT1.5kVA 2U Rack or Tower UPS (100-125VAC) |
55942AX | RT2.2kVA 2U Rack or Tower UPS (100-125VAC) |
7DD5A003WW | RT3kVA 2U Rack or Tower UPS-G2 (100-125VAC) |
55943AX | RT3kVA 2U Rack or Tower UPS (100-125VAC) |
Rack-mounted or tower UPS units - 200-240VAC | |
7DD5A002WW | RT1.5kVA 2U Rack or Tower UPS-G2 (200-240VAC) |
55941KX | RT1.5kVA 2U Rack or Tower UPS (200-240VAC) |
55942KX | RT2.2kVA 2U Rack or Tower UPS (200-240VAC) |
7DD5A005WW | RT3kVA 2U Rack or Tower UPS-G2 (200-240VAC) |
55943KX | RT3kVA 2U Rack or Tower UPS (200-240VAC) |
7DD5A007WW | RT5kVA 3U Rack or Tower UPS-G2 (200-240VAC) |
55945KX | RT5kVA 3U Rack or Tower UPS (200-240VAC) |
7DD5A008WW | RT6kVA 3U Rack or Tower UPS-G2 (200-240VAC) |
55946KX | RT6kVA 3U Rack or Tower UPS (200-240VAC) |
55948KX | RT8kVA 6U Rack or Tower UPS (200-240VAC) |
7DD5A00AWW | RT11kVA 6U Rack or Tower UPS-G2 (200-240VAC) |
55949KX | RT11kVA 6U Rack or Tower UPS (200-240VAC) |
55943KT† | ThinkSystem RT3kVA 2U Standard UPS (200-230VAC) (2x C13 10A, 2x GB 10A, 1x C19 16A outlets) |
55943LT† | ThinkSystem RT3kVA 2U Long Backup UPS (200-230VAC) (2x C13 10A, 2x GB 10A, 1x C19 16A outlets) |
55946KT† | ThinkSystem RT6kVA 5U UPS (200-230VAC) (2x C13 10A outlets, 1x Terminal Block output) |
5594XKT† | ThinkSystem RT10kVA 5U UPS (200-230VAC) (2x C13 10A outlets, 1x Terminal Block output) |
Rack-mounted or tower UPS units - 380-415VAC | |
55948PX | RT8kVA 6U 3:1 Phase Rack or Tower UPS (380-415VAC) |
55949PX | RT11kVA 6U 3:1 Phase Rack or Tower UPS (380-415VAC) |
† Only available in China and the Asia Pacific market.
For more information, see the list of Product Guides in the UPS category:
https://lenovopress.com/servers/options/ups
Related product families
Product families related to this document are the following:
Trademarks
Lenovo and the Lenovo logo are trademarks or registered trademarks of Lenovo in the United States, other countries, or both. A current list of Lenovo trademarks is available on the Web at https://www.lenovo.com/us/en/legal/copytrade/.
The following terms are trademarks of Lenovo in the United States, other countries, or both:
Lenovo®
ThinkAgile®
ThinkSystem®
The following terms are trademarks of other companies:
UltraScale+™ and UltraScale™ are trademarks of Advanced Micro Devices, Inc.
Microsoft® and Excel® are trademarks of Microsoft Corporation in the United States, other countries, or both.
Other company, product, or service names may be trademarks or service marks of others.