Author
Updated
7 May 2024Form Number
LP1090PDF size
30 pages, 691 KB- Physical specifications
- Operating environment
- Warranty and support
- Services
- Regulatory compliance
- Interoperability
- External storage systems
- External backup units
- Rack cabinets
- Power distribution units
- Uninterruptible power supply units
- Seller training courses
- Related publications and links
- Related product families
- Trademarks
Abstract
The Lenovo ThinkSystem DB630S FC SAN Switch delivers 32 Gb Gen 6 Fibre Channel technology with industry-leading port density and combines scalability, reliability, flexibility, simplicity, and enterprise-class functionality to meet the demands of hyper-scale, private cloud storage, and growing flash-based and NVMe storage environments.
The DB630S FC SAN switch offers a rich set of standard features with the options to expand its capabilities as needed, providing “pay-as-you-grow” scalability to meet the needs of an evolving storage environment.
This product guide provides essential technical and pre-sales information on the ThinkSystem DB630S FC SAN Switch, its key features and specifications, components and options, and configuration guidelines.
This guide is intended for technical specialists, sales specialists, sales engineers, IT architects, and other IT professionals who want to learn more about the ThinkSystem DB630S FC SAN Switch and consider its use in IT solutions.
Change History
Changes in the May 7, 2024 update:
- The following have been withdrawn under Transceivers and cables section:
- Brocade 10Gb FC SWL SFP+ Transceiver, 00YH933
- Brocade 10Gb FC LWL SFP+ Transceiver, 00YH929
- Brocade 16Gb SWL SFP+ Optical Transceiver, 88Y6393
- Brocade 32Gb LWL SFP+ Transceiver, 01KN793
- Brocade 32Gb LWL SFP+ Transceiver (8-pack), 01KN799
- Brocade SAN switch, B300
- The following have been added under Transceivers and cables section:
- Brocade SAN switch, DB730S
- Transceiver, 4x 32 Gb FC SWL QSFP+, 4M27A65422
- 16 Gb FC LWL SFP+, 4M27A65413, 4M27A65414
Introduction to the ThinkSystem DB630S Fibre Channel SAN Switch
Introduction
The Lenovo ThinkSystem DB630S FC SAN Switch delivers 32 Gb Gen 6 Fibre Channel technology with industry-leading port density and combines scalability, reliability, flexibility, simplicity, and enterprise-class functionality to meet the demands of hyper-scale, private cloud storage, and growing flash-based and NVMe storage environments.
The DB630S FC SAN Switch is a dense, 2U rack-mount storage networking switch that offers 96x SFP+ ports that support 4/8/10/16/32 Gbps speeds and 8x QSFP+ ports that support 128 Gbps (4x 32 Gbps) or 4x 4/8/16/32 Gbps speeds. The DB630S FC SAN switch offers a rich set of standard features with the options to expand its capabilities as needed, providing “pay-as-you-grow” scalability to meet the needs of an evolving storage environment.
The DB630S FC SAN Switch features the EZSwitchSetup wizard to simplify deployment, and it provides easy integration into the existing SAN environments while realizing the benefits of Gen 6 Fibre Channel connectivity. The switch provides full non-blocking performance with Ports On Demand scalability to support SAN expansion and enable long-term investment protection.
The following figure shows the Lenovo ThinkSystem DB630S 32Gb FC SAN Switch.
Figure 1. Lenovo ThinkSystem DB630S 32Gb FC SAN Switch
Did you know?
The DB630S FC SAN Switch leverages storage connectivity technologies from Brocade, a leader in Fibre Channel networking.
Fabric Vision technology, an extension of Gen 6 Fibre Channel, provides unprecedented insight and visibility across the SAN with powerful built-in monitoring, management, and diagnostic tools.
With Lenovo FC SAN Switch offerings, Lenovo can be your trusted partner that offers "one stop shop" and single point of contact for delivery of leading edge technologies and innovations from Lenovo and other leading IT vendors. These offerings can satisfy the wide range of your end-to-end IT infrastructure needs, including end-user devices, servers, storage, networking, services, management software, and financing.
Key features
The ThinkSystem DB630S FC SAN Switch offers the following features and benefits:
- Provides high scalability in a dense, 2U switch with 96 SFP+ ports and 8 QSFP+ ports (each QSFP+ port has 4x 32 Gb FC links for 128 Gb FC connectivity between the DB630S or DB620S FC SAN switches, or it can be broken out to four links to 4/8/16/32 Gbps SWL optics in a server HBA, storage device, or another FC switch, for a total of up to 128 connections) to support high-density server virtualization, cloud architectures, and flash-based storage environments.
- Enables cost-effective “pay-as-you-grow” scalability from 48 to 128 ports with Ports On Demand (POD).
- Increases performance for demanding workloads with support for 128 Gbps (4x 32 Gbps) and 32 Gbps FC links.
- Simplifies end-to-end management of large-scale environments by automating repetitive daily management tasks.
- Optimizes fabric behavior and ensure sufficient bandwidth for mission-critical applications with advanced traffic management capabilities and adaptive networking.
- Provides proactive, non-intrusive, real-time monitoring and alerting of VM and storage I/O health and performance with VM Insight and IO Insight through integrated network sensors.
- Leverages predefined MAPS policies to automatically identify and isolate devices that cause network performance issues.
- Protects existing device investments with auto-sensing 4, 8, 16, and 32 Gbit/sec capabilities and native operation with Brocade fabrics.
- Runs Fabric OS, which delivers distributed intelligence throughout the network and enables a wide range of value-added features.
- Leverages Fabric Vision technology’s powerful monitoring, management, and diagnostic tools to simplify administration, increase uptime, and reduce costs.
- Supplies a rich set of standard features at no extra cost, including fabric services, advanced zoning, adaptive networking, full fabric operations, integrated 10 Gb FC, and diagnostic tools.
- Expands fabric capabilities with optional licensed functions, including trunking, advanced monitoring and alerting, long-distance fabrics, and FC-FC routing.
- Compresses and encrypts in-flight data on up to 12 ports for more efficient link utilization and higher security.
- Virtualizes physical FC SAN switches and fabrics into logical entities for better flexibility, utilization, management, and efficiency.
- Allows organizations to seamlessly integrate Gen 6 Fibre Channel networks with the next generation of flash storage – NVMe over Fibre Channel – by being NVMe-ready, without a disruptive rip and replace, to achieve faster application response times and harness the performance of solid state drives for better scalability across virtual data centers with flash storage.
- Optimizes performance and ensures reliability with enhanced monitoring for NVMe.
- Maximizes resiliency with redundant hot-swap fan assembly units and power supplies.
- Accelerates troubleshooting with built-in advanced diagnostics tools featuring ClearLink Diagnostics with D_Ports and select adapters from QLogic and Emulex, which helps ensure optical and signal integrity for 16 Gb and 32 Gb Fibre Channel optics and cables.
Components and connectors
The following figure shows the port-side view of the DB630S FC SAN Switch.
Figure 2. DB630S FC SAN Switch port-side view
The port-side panel of the DB630S FC SAN Switch includes the following components:
- 96x SFP+ ports to attach SFP+ transceivers for 4/8/10/16/32 Gb FC connections.
- 8x QSFP+ ports to attach QSFP+ transceivers for 128 Gb or 4x 32 Gb FC connections.
- One RJ-45 10/100/1000 Mb Ethernet port for out-of-band management.
- One RJ-45 RS-232 console port for configuring the switch.
- One USB port for mass storage devices.
- LEDs that display the status of the switch and the network.
The following figure shows the non-port side view of the DB630S FC SAN Switch.
Figure 3. DB630S FC SAN Switch non-port-side view
The non-port-side panel of the DB630S FC SAN Switch includes the following components:
- Two redundant hot-swap 1500 W AC power supplies (each with the IEC 320-C14 power connector).
- Three N+1 redundant hot-swap system fan assembly units (each with two fans).
System specifications
The following table lists the ThinkSystem DB630S system specifications.
Models
The following table lists the ThinkSystem DB630S FC SAN Switch models.
The DB630S FC SAN Switch models ship with the following items:
- One FC SAN Switch with 1-year firmware entitlement
- Model CTO1: With 48 ports activated and no transceivers included
- Models CTO2 and CTO5: With 48 ports activated and 48x 32 Gb FC SWL SFP+ transceivers included
- Models CTO3 and CTO6: With 96 ports activated and 96x 32 Gb FC SWL SFP+ transceivers included
- Serial cable (DB-9/RJ-45 to RJ-45)
- Rubber feet for setting up the switch as a standalone unit
- Fixed rack mount kit
- EZSwitchSetup web pointer card
- Online Documentation web pointer card
- SANnav web pointer card
Note: The switch comes standard without power cords; two power cables must be purchased together with the switch (see Power supplies and cables for details).
Port activation licenses
DB630S Model CTO1 ships with 48 licensed ports (transceivers are not included), and the Models CTO2 and CTO5 ships with 48 licensed ports and 48x 32 Gb FC SWL SFP+ Transceivers. The remaining 48 SFP+ unlicensed ports can be activated by purchasing and installing the SFP+ Ports on Demand (POD) licenses that are available in 24-port increments. DB630S Models CTO3 and CTO6 ships with 96 licensed ports and 96x 32 Gb FC SWL SFP+ Transceivers.
Eight QSFP+ unlicensed ports on the DB630S FC SAN Switch can be activated by purchasing and installing the QSFP+ POD license that is available with or without QSFP+ transceivers.
The following table lists additional POD options for the DB630S FC SAN Switch.
Transceivers and cables
With the flexibility of the DB630S FC SAN Switch, customers can choose the following connectivity technologies:
- QSFP+ ports
- For 128 Gb (4x 32 Gb) FC links for connectivity between the DB630S or DB620S FC SAN Switches, customers can use 128 Gb FC QSFP+ SWL optical transceivers for distances up to 100 meters on OM4 or up to 70 meters on OM3 50 µ multimode fiber (MMF) optic cables. For longer distances, the 128 Gb (4x 32 Gb) FC 2KM LWL QSFP+ optical transceivers can support up to 2 kilometers on single-mode fiber (SMF) cables. The 4x 32 Gb FC links per QSFP+ port can be configured as 128 Gbps parallel FC [round robin 66-bit block distribution across four lanes] or in a 128 Gbps ISL trunk group.
- For 32 Gb FC links, customers can use the 128 Gb (4x 32 Gbps) SWL QSFP+ Transceiver v2 with OM4 MMF MPO-4xLC breakout cables for distances up to 100 meters or OM3 MMF MPO-4xLC breakout cables for distances up to 70 meters.
- For 16 Gb FC links, customers can use 50 µ MMF MPO-4xLC breakout cables for connectivity to other FC SAN switches or routers (E_Port or EX_Port) by using four independent 16 Gb FC links per QSFP+ port (no ISL trunking) with the following transceivers:
- 128 Gb (4x 32 Gb) QSFP+ SWL v2 optical transceivers running at 4x 16 Gb speeds for distances up to 125 meters on OM4 or up to 100 meters on OM3 MMF cables.
- 4x 16 Gb FC QSFP+ SWL optical transceivers for distances up to 100 meters on OM4 or up to 66 meters on OM3 MMF cables.
- SFP+ ports
- For 32 Gb FC links, customers can use 32 Gb FC SFP+ SWL optical transceivers for distances up to 100 meters on OM4 or up to 70 meters on OM3 50 µ MMF cables. For longer distances, the 32 Gb FC LWL SFP+ optical transceivers can support up to 10 km on SMF cables. For extended distances, the 32 Gb FC ELWL SFP+ optical transceivers can support up to 25 kilometers on SMF cables. These transceivers can operate at 32 Gbps, 16 Gbps, or 8 Gbps speeds. (Except ELWL part number 4M27A65431 which can only operate at 32Gbps and 16 Gbps).
- For 16 Gb FC links, customers can use 16 Gb FC SFP+ SWL optical transceivers for distances up to 125 meters on OM4 or up to 100 meters on OM3 50 µ MMF cables. For longer distances, the 16 Gb FC LWL SFP+ optical transceivers can support up to 10 kilometers on SMF cables. For extended distances, the 16 Gb FC ELWL SFP+ optical transceivers can support up to 25 kilometers on SMF cables. These transceivers can operate at 16 Gbps, 8 Gbps, or 4 Gbps speeds.
- For 10 Gb FC links, customers can use 10 Gb FC SFP+ SWL transceivers for distances up to 550 meters on OM4 or up to 300 meters on OM3 50 µ MMF cables, or 10 Gb FC SFP+ LWL transceivers for distances up to 10 km on SMF cables. 10 Gb FC operations allow metro connectivity by directly utilizing a fiber optic cable between sites or by creating multiple channels on an optical cable between sites, utilizing Wave Division Multiplexing (WDM) technology (the Extended Fabric feature is NOT required for long distance 10 Gb FC connectivity).
- 1 GbE RJ-45 management port: Customers can use UTP Category 5, 5e, or 6 cables for distances up to 100 meters.
The DB630S FC SAN Switch comes with 48x (Models CTO2 and CTO5) or 96x (Models CTO3 and CTO6) 32 Gb FC SWL SFP+ transceivers, or without any transceivers (Model CTO1). Additional SWL, LWL, and ELWL SFP+ and SWL and LWL QSFP+ transceivers can be ordered for the switch, if needed.
The following table lists the supported transceiver and cable options.
Brocade Secure transceivers: These new Secure transceivers have features to ensure that you are using genuine Brocade components to maximize performance and reliability and to help avoid issues related to counterfeit products.
* When using ELW SFP+ transceivers over distances over 10 km, the Extended Fabric feature that is available in the Enterprise Bundle is required on a SAN switch to drive the maximum bandwidth over the extended links.
** The specific ELWL only operates at 32 Gbps and 16Gbps. The Extended Fabric feature that is available in the Enterprise or Mainframe Enterprise Bundle is required on a SAN switch to drive the maximum bandwidth over the extended links. Requires minimum FOS 9.1.1.
*** ELWL Requires same optic type/part number on both ends (no-mixing) to assure interoperability.
The following table lists the cabling requirements for the switch.
Transceiver | Standard | Cable | Connector |
---|---|---|---|
128 Gb (4x 32 Gb) Fibre Channel | |||
128 Gb (4x 32 Gb) FC SWL QSFP+ v2 (4M27A08820) | FC-PI-6P FC-PI-6 |
Up to 30 m with MPO-MPO MMF cables or up to 5 m with MPO-4xLC MMF breakout cables supplied by Lenovo (see Table 4). 850 nm 50 µ MPO-MPO MMF cable or MPO-4xLC MMF breakout cable:
|
MPO |
128 Gb (4x 32 Gb) FC 2km LWL QSFP+ (4M27A09986) | FC-PI-6P FC-PI-6 |
1310 nm 9 µ SMF cable:
|
LC |
32 Gb Fibre Channel | |||
32 Gb FC SWL SFP+ (01KN789, 01KN793, 4M27A65416, 4M27A65417) | FC-PI-6 |
Up to 30 m with LC-LC MMF cables supplied by Lenovo (see Table 4). 850 nm 50 µ MMF cable:
|
LC |
4x 32 Gb FC SWL QSFP+ (4M27A65422) | FC-PI-6 |
Up to 30 m with MPO-MPO MMF optical cables or up to 5 m with MPO-4xLC optical breakout cables supplied by Lenovo (see Table 4). 850 nm 50 µ MMF cable:
|
MPO |
32 Gb FC LWL SFP+ (01KN795, 01KN799, 4M27A65418, 4M27A65419) | FC-PI-6 | 1310 nm 9 µ SMF cable:
|
LC |
32 Gb FC ELWL SFP+ (4M27A65424, 4M27A65431) | FC-PI-6 | 1310 nm 9 µ SMF cable:
|
LC |
16 Gb Fibre Channel | |||
16 Gb FC SWL SFP+ (88Y6393, 4M27A65411, 4M27A65412) |
FC-PI-6 |
Up to 30 m with LC-LC MMF cables supplied by Lenovo (see Table 4). 850 nm 50 µ MMF cable:
|
LC |
4x 16 Gb FC SWL QSFP+ (01KN805) | FC-PI-6 |
Up to 30 m with MPO-MPO MMF optical cables or up to 5 m with MPO-4xLC optical breakout cables supplied by Lenovo (see Table 4). 850 nm 50 µ MMF cable:
|
MPO |
16 Gb FC LWL SFP+ (4M27A65413, 4M27A65414) | FC-PI-6 | 1310 nm 9 µ single-mode fiber optic cable:
|
LC |
16 Gb FC LWL SFP+ (00MY768) | FC-PI-5 | 1310 nm 9 µ SMF cable:
|
LC |
16 Gb FC ELWL SFP+ (00MY770, 4M27A65415) | FC-PI-6 | 1310 nm 9 µ SMF cable:
|
LC |
10 Gb Fibre Channel | |||
10 Gb FC SWL SFP+ (00YH933, 4M27A65421) | FC-10GFC | 850 nm 50 µ MMF cable:
|
LC |
10 Gb FC LWL SFP+ (00YH929, 4M27A65420) | FC-10GFC | 1310 nm 9 µ SMF cable:
|
LC |
Management ports | |||
10/100/1000 Mb Ethernet port | 1000BASE-T |
Up to 25 m with UTP cables supplied by Lenovo (see Table 4). UTP Category 5, 5E, and 6 up to 100 meters. |
RJ-45 |
Enterprise Bundles and Integrated Routing features
For details on the latest features supported with the FC SAN Switch see the Administration Guide for the latest available Fabric OS version 9.0 and above, available from:
https://www.broadcom.com/products/fibre-channel-networking/software/fabric-operating-system
The following optional features are available for the DB630S FC SAN Switch:
- Enterprise Bundle
- ISL Trunking (TRK): Allows frame-based consolidation of up to 8 inter-switch links (ISLs) into fault-tolerant and load-balanced trunks with bandwidth of up to 256 Gbps.
- Fabric Vision (FV)
- Monitoring and Alerting Policy Suite (MAPS): Simplifies fabric-wide threshold configuration, monitoring, and alerting with pre-built, rule-based or policy-based templates. Administrators can configure the entire fabric (or multiple fabrics) at one time using common rules and policies, or customize policies for specific ports or switch elements. In addition, administrators can use IO Insight metrics to set thresholds in MAPS policies in order to be notified of application, VM, and storage IOI/O performance degradation.
- Flow Vision: Enables administrators to identify, monitor, and analyze specific application flows in order to simplify troubleshooting, maximize performance, avoid congestion, and optimize resources. Flow Vision includes:
- Flow Monitor: Provides comprehensive visibility, automatic learning, and non-disruptive monitoring of a flow’s performance. Administrators can monitor all flows from a specific host to multiple targets or volumes, from multiple hosts to a specific target/volume, or across a specific ISL. Additionally, they can perform volume-level monitoring of specific frame types to identify resource contention or congestion that is impacting application performance. With the IO Insight capability, administrators can monitor first I/O response time, I/O completion time, the number of pending I/Os, and IOPS metrics for a flow from a specific host to a target or volume running SCSI or NVMe over Fibre Channel traffic. With VM Insight, administrators can monitor network throughput and I/O statistics for each VM.
- Flow Learning: Enables administrators to non-disruptively discover all flows that go to or come from a specific host port or a storage port, or traverse ISLs/IFLs (Inter-Fabric Links) or Fibre Channel over Internet Protocol (FCIP) tunnels, to monitor fabric-wide application performance. In addition, administrators can discover top and bottom bandwidth-consuming devices and manage capacity planning.
- Flow Generator: Provides a built-in traffic generator for pretesting and validating the data center infrastructure for robustness—including route verification and integrity of optics, cables, ports, back-end connections, and ISLs—before deploying applications.
- Flow Mirroring: Enables administrators to non-disruptively create copies of specific application and data flows or frame types that can be captured for in-depth analysis.
- VM Insight: Seamlessly monitors health and performance of individual Virtual Machines (VMs) to quickly identify abnormal VM behavior and enable administrators to proactively facilitate troubleshooting and fault isolation, helping to ensure performance and operational stability.
- IO Insight: Proactively monitors I/O performance and behavior to gain deep insight into issues and ensure service levels by non-disruptively and non-intrusively gathering I/O statistics for storage traffic and applying this information within a policy-based monitoring and alerting suite to configure thresholds and alarms.
- Fabric Performance Impact (FPI) Monitoring: Leverages predefined MAPS policies to automatically detect and alert administrators to different latency severity levels, and to identify slow drain devices that could impact network performance. This feature identifies various latency severity levels, pinpointing exactly which devices are causing or are impacted by a bottlenecked port, and quarantines slow drain devices automatically to prevent buffer credit starvation.
-
Extended Fabric (EF): Extends Fibre Channel SANs beyond 10 km distance limitations for replication and backup at full bandwidth.
- Integrated Routing: The FC-FC routing service provides Fibre Channel routing between two or more fabrics without merging those fabrics.
The following table lists ordering information for the optional licensed features for the DB630S FC SAN Switch.
Configuration note: The DB630S FC SAN Switch Models CTO3 and CTO6 come with the Enterprise Bundle license included.
Firmware entitlement is included with the DB630S FC SAN Switch and provides 1-year firmware support. The entitlement extensions for additional years of firmware support are included in the warranty service upgrades and post-warranty extensions.
The Integrated Routing feature (7S0C0018WW) comes with its own 1-year firmware support entitlement. The options to extend entitlement for additional years of firmware support for the Integrated Routing feature are listed in the following table.
Management software
Lenovo offers optional Brocade SANnav™ Management Portal and SANnav Global View software license subscriptions that provide comprehensive visibility into the SAN environment, allow administrators to quickly identify, isolate, and correct problems, and accelerate administrative tasks by simplifying and automating workflows.
SANnav Management Portal is a next-generation SAN management application with a simple browser-based user interface (UI) and with a focus on streamlining common workflows, such as configuration, zoning, deployment, monitoring, troubleshooting, reporting, and analytics.
Lenovo offers the following SANnav Management Portal subscriptions:
- SANnav Management Portal Base: Designed for mid-sized SANs to manage up to 600 SAN switch ports only (SAN director ports can only be managed with the Enterprise edition).
- SANnav Management Portal Enterprise: Designed for enterprise-class SANs to manage up to 15 000 SAN switch and director ports.
SANnav Management Portal supports all Brocade SAN switches and platforms that run the Fabric OS® version 7.4 or above, including Lenovo B300, B6505, B6510, DB610S, DB620S, DB400D, DB720S, DB730S, DB800D, Brocade Directors, and FC5022.
With SANnav Global View, administrators can quickly visualize the health, performance, and inventory of multiple SANnav Management Portal instances using a simple, intelligent dashboard and can easily navigate from a global view down to local environments to investigate points of interest. SANnav Global View is designed to manage up to 20 SANnav Management Portal instances.
For more information, refer to the SANnav Management Portal documentation:
http://www.broadcom.com/products/fibre-channel-networking/software/sannav-management-portal#documentation
The following table lists ordering information for the optional SANnav Management Portal and SANnav Global View management tools. After a client has an active SANnav license, Lenovo offers a “license extension/renewal”. This offering provides our clients the flexible to extend their subscription down to a specific end date. This allows clients the ability to align to your company’s budget or align with warranty of your FC SAN switches/directors. Please engage directly with your Lenovo sales representative for more details.
The SANnav licenses are subscription-based with 1-year, 3-year, or 5-year software entitlement and support.
Fibre Channel standards
The FC SAN Switch supports the standards listed at the following web page:
https://www.broadcom.com/support/fibre-channel-networking/san-standards/standards-compliance
Power supplies and cables
The DB630S FC SAN Switch ships with two redundant hot-swap 1500 W AC power supplies. Each power supply has an IEC 309-C14 connector.
The switch comes standard without a power cord; two rack power cables or line cords must be ordered together with the switch (see the following table).
* Available for factory-built custom configurations and solutions only.
Rack installation
The DB630S FC SAN Switch comes standard with the fixed rack mount kit that can be used for 4-post rack installations. If needed, the DB630S FC SAN Switch can be mounted in a 2-post rack cabinet by using the optional mid-mount rack kit that is listed in the following table.
Description | Part number | Feature code | Maximum quantity |
---|---|---|---|
Lenovo Mid-mount Rack Kit | 01KN770 | AVG7 | 1 |
The optional mid-mount rack kit for the DB630S FC SAN Switch is shown in the following figure.
Figure 4. Lenovo DB630S Mid-mount Rack Kit
Physical specifications
The DB630S FC SAN Switch has the following dimensions and weight (approximate):
- Height: 87 mm (3.4 in.)
- Width: 440 mm (17.3 in.)
- Depth: 610 mm (24.0 in.)
- Weight: 21.31 kg (47.0 lb) with two power supply FRUs, and three fan FRUs without transceivers
Operating environment
The DB630S FC SAN Switch is supported in the following environment:
- Air temperature:
- Operating: 0°C to 40°C (32°F to 104°F)
- Non-operating: -25°C to +70°C (-13°F to 158°F)
- Maximum altitude:
- Operating: 3 000 m (9,842 ft)
- Non-operating: 12 000 m (39,370 ft)
- Humidity:
- Operating: 10% to 85% non-condensing
- Non-operating: 10% to 90% non-condensing
- Electrical power:
- Voltage range: 100 V AC - 240 V AC (nominal)
- Frequency: 50 Hz / 60 Hz (nominal)
- Power consumption:
- Idle: 495 watts
- Typical: 536 watts
- Maximum: 942 watts
- Heat dissipation:
- Idle: 1689 BTU per hour
- Typical: 1829 BTU per hour
- Maximum: 3215 BTU per hour
- Acoustical noise emission: 74.2 dB
Warranty and support
The DB630S FC SAN Switch has a one-year customer-replaceable unit (CRU) limited warranty with standard call center support during normal business hours and 9x5 Next Business Day Parts Delivered.
Lenovo’s additional support services provide a sophisticated, unified support structure for a customer's data center, with an experience consistently ranked number one in customer satisfaction worldwide.
The following Lenovo support services are available:
- Warranty Upgrades (Preconfigured Support) are available to meet the on-site response time targets that match the criticality of customer's systems:
- 1, 3, or 5 years of warranty service coverage.
- 1-year or 2-year post-warranty extensions.
- Foundation Service: 9x5 service coverage with next business day onsite response.
- Essential Service: 24x7 service coverage with 4-hour onsite response or 24-hour committed repair (available only in select regions).
- Advanced Service: 24x7 service coverage with 2-hour onsite response or 6-hour committed repair (available only in select regions).
- Managed Services
Lenovo Managed Services provide continuous 24x7 remote monitoring (plus 24x7 call center availability) and proactive management of a customer's data center using state of the art tools, systems, and practices by a team of highly skilled and experienced Lenovo services professionals.
Quarterly reviews check error logs, verify firmware and operating system device driver levels, and software as needed. Lenovo will also maintain records of latest patches, critical updates, and firmware levels, to ensure customer's systems are providing business value through optimized performance.
- Technical Account Management (TAM)
A Lenovo Technical Account Manager helps customers optimize operations of their data centers based on a deep understanding of customer's business. Customers gain direct access to a Lenovo TAM, who serves as their single point of contact to expedite service requests, provide status updates, and furnish reports to track incidents over time. Also, a TAM helps proactively make service recommendations and manage service relationship with Lenovo to make certain that customer's needs are met.
- Health Check
Having a trusted partner who can perform regular and detailed health checks is central to maintaining efficiency and ensuring that customer systems and business are always running at their best. Health Check supports Lenovo-branded server, storage, and networking devices, as well as select Lenovo-supported products from other vendors that are sold by Lenovo or a Lenovo-Authorized Reseller.
Some regions might have different warranty terms and conditions than the standard warranty. This is due to local business practices or laws in the specific region. Local service teams can assist in explaining region-specific terms when needed. Examples of region-specific warranty terms are second or longer business day parts delivery or parts-only base warranty.
If warranty terms and conditions include onsite labor for repair or replacement of parts, Lenovo will dispatch a service technician to the customer site to perform the replacement. Onsite labor under base warranty is limited to labor for replacement of parts that have been determined to be field-replaceable units (FRUs). Parts that are determined to be customer-replaceable units (CRUs) do not include onsite labor under base warranty.
If warranty terms include parts-only base warranty, Lenovo is responsible for delivering only replacement parts that are under base warranty (including FRUs) that will be sent to a requested location for self-service. Parts-only service does not include a service technician being dispatched onsite. Parts must be changed at customer’s own cost and labor and defective parts must be returned following the instructions supplied with the spare parts.
Lenovo support services are region-specific. Not all support services are available in every region. For information about Lenovo support services that are available in a specific region, refer to the following resources:
- Service part numbers in Data Center Solution Configurator (DCSC):
http://dcsc.lenovo.com/#/services - Lenovo Services Availability Locator
https://lenovolocator.com/
For service definitions, region-specific details, and service limitations, refer to the following documents:
- Lenovo Statement of Limited Warranty for Infrastructure Solutions Group (ISG) Servers and System Storage
http://pcsupport.lenovo.com/us/en/solutions/ht503310 - Lenovo Data Center Services Agreement
http://support.lenovo.com/us/en/solutions/ht116628
Services
Lenovo Data Center Services empower you at every stage of your IT lifecycle. From expert advisory and strategic planning to seamless deployment and ongoing support, we ensure your infrastructure is built for success. Our comprehensive services accelerate time to value, minimize downtime, and free your IT staff to focus on driving innovation and business growth.
Note: Some service options may not be available in all markets or regions. For more information, go to https://lenovolocator.com/. For information about Lenovo service upgrade offerings that are available in your region, contact your local Lenovo sales representative or business partner.
In this section:
- Lenovo Advisory Services
- Lenovo Plan & Design Services
- Lenovo Deployment, Migration, and Configuration Services
- Lenovo Support Services
- Lenovo Managed Services
- Lenovo Sustainability Services
Lenovo Advisory Services
Lenovo Advisory Services simplify the planning process, enabling customers to build future-proofed strategies in as little as six weeks. Consultants provide guidance on projects including VM migration, storage, backup and recovery, and cost management to accelerate time to value, improve cost efficiency, and build a flexibly scalable foundation.
- Assessment Services
An Assessment helps solve your IT challenges through an onsite, multi-day session with a Lenovo technology expert. We perform a tools-based assessment which provides a comprehensive and thorough review of a company's environment and technology systems. In addition to the technology based functional requirements, the consultant also discusses and records the non-functional business requirements, challenges, and constraints. Assessments help organizations like yours, no matter how large or small, get a better return on your IT investment and overcome challenges in the ever-changing technology landscape.
- Design Services
Professional Services consultants perform infrastructure design and implementation planning to support your strategy. The high-level architectures provided by the assessment service are turned into low level designs and wiring diagrams, which are reviewed and approved prior to implementation. The implementation plan will demonstrate an outcome-based proposal to provide business capabilities through infrastructure with a risk-mitigated project plan.
Lenovo Plan & Design Services
Unlock faster time to market with our tailored, strategic design workshops to align solution approaches with your business goals and technical requirements. Leverage our deep solution expertise and end-to-end delivery partnership to meet your goals efficiently and effectively.
Lenovo Deployment, Migration, and Configuration Services
Optimize your IT operations by shifting labor-intensive functions to Lenovo's skilled technicians for seamless on-site or remote deployment, configuration, and migration. Enjoy peace of mind, faster time to value, and comprehensive knowledge sharing with your IT staff, backed by our best-practice methodology.
- Deployment Services for Storage and ThinkAgile
A comprehensive range of remote and onsite options tailored specifically for your business needs to ensure your storage and ThinkAgile hardware are fully operational from the start.
- Hardware Installation Services
A full-range, comprehensive setup for your hardware, including unpacking, inspecting, and positioning components to ensure your equipment is operational and error-free for the most seamless and efficient installation experience, so you can quickly benefit from your investments.
- DM/DG File Migration Services
Take the burden of file migration from your IT’s shoulders. Our experts will align your requirements and business objectives to the migration plans while coordinating with your team to plan and safely execute the data migration to your storage platforms.
- DM/DG/DE Health Check Services
Our experts perform proactive checks of your Firmware and system health to ensure your machines are operating at peak and optimal efficiency to maximize up-time, avoid system failures, ensure the security of IT solutions and simplify maintenance.
- Factory Integrated Services
A suite of value-added offerings provided during the manufacturing phase of a server or storage system that reduces time to value. These services aim at improving your hardware deployment experience and enhance the quality of a standard configuration before it arrives at your facility.
Lenovo Support Services
In addition to response time options for hardware parts, repairs, and labor, Lenovo offers a wide array of additional support services to ensure your business is positioned for success and longevity. Our goal is to reduce your capital outlays, mitigate your IT risks, and accelerate your time to productivity.
- Premier Support for Data Centers
Your direct line to the solution that promises the best, most comprehensive level of support to help you fully unlock the potential of your data center.
- Premier Enhanced Storage Support (PESS)
Gain all the benefits of Premier Support for Data Centers, adding dedicated storage specialists and resources to elevate your storage support experience to the next level.
- Committed Service Repair (CSR)
Our commitment to ensuring the fastest, most seamless resolution times for mission-critical systems that require immediate attention to ensure minimal downtime and risk for your business. This service is only available for machines under the Premier 4-Hour Response SLA.
- Multivendor Support Services (MVS)
Your single point of accountability for resolution support across vast range of leading Server, Storage, and Networking OEMs, allowing you to manage all your supported infrastructure devices seamlessly from a single source.
- Keep Your Drive (KYD)
Protect sensitive data and maintain compliance with corporate retention and disposal policies to ensure your data is always under your control, regardless of the number of drives that are installed in your Lenovo server.
- Technical Account Manager (TAM)
Your single point of contact to expedite service requests, provide status updates, and furnish reports to track incidents over time, ensuring smooth operations and optimized performance as your business grows.
- Enterprise Software Support (ESS)
Gain comprehensive, single-source, and global support for a wide range of server operating systems and Microsoft server applications.
For more information, consult the brochure Lenovo Operational Support Services for Data Centers.
Lenovo Managed Services
Achieve peak efficiency, high security, and minimal disruption with Lenovo's always-on Managed Services. Our real-time monitoring, 24x7 incident response, and problem resolution ensure your infrastructure operates seamlessly. With quarterly health checks for ongoing optimization and innovation, Lenovo's remote active monitoring boosts end-user experience and productivity by keeping your data center's hardware performing at its best.
Lenovo Managed Services provides continuous 24x7 remote monitoring (plus 24x7 call center availability) and proactive management of your data center using state-of-the-art tools, systems, and practices by a team of highly skilled and experienced Lenovo services professionals.
Quarterly reviews check error logs, verify firmware & OS device driver levels, and software as needed. We’ll also maintain records of latest patches, critical updates, and firmware levels, to ensure you systems are providing business value through optimized performance.
Lenovo Sustainability Services
- Asset Recovery Services
Lenovo Asset Recovery Services (ARS) provides a secure, seamless solution for managing end-of-life IT assets, ensuring data is safely sanitized while contributing to a more circular IT lifecycle. By maximizing the reuse or responsible recycling of devices, ARS helps businesses meet sustainability goals while recovering potential value from their retired equipment. For more information, see the Asset Recovery Services offering page.
- CO2 Offset Services
Lenovo’s CO2 Offset Services offer a simple and transparent way for businesses to take tangible action on their IT footprint. By integrating CO2 offsets directly into device purchases, customers can easily support verified climate projects and track their contributions, making meaningful progress toward their sustainability goals without added complexity.
- Lenovo Certified Refurbished
Lenovo Certified Refurbished offers a cost-effective way to support IT circularity without compromising on quality and performance. Each device undergoes rigorous testing and certification, ensuring reliable performance and extending its lifecycle. With Lenovo’s trusted certification, you gain peace of mind while making a more sustainable IT choice.
Regulatory compliance
The DB630S FC SAN Switch conforms to the following regulations:
- United States: FCC Part 15, Subpart B, Class A; UL 60950-1
- Canada: ICES-003
- European Union:
- CE Mark (EN55032 Class A, IEC/EN60950-1, EN55024, EN61000-3-2, EN61000-3-3)
- EN 300 386
- EN 60825
- China: GB4943.1, GB9254
- Japan: VCCI
- Taiwan: BSMI CNS13438, CNS14336-1
- Korea: KN32, KN35
- Australia/New Zealand: AS/NZS CISPR 32, Class A
- Restriction of Hazardous Substances (RoHS)
Interoperability
For end-to-end storage configuration support, refer to the Lenovo Storage Interoperation Center (LSIC):
https://datacentersupport.lenovo.com/us/en/lsic
Use the LSIC to select the known components of your configuration and then get a list all other supported combinations, with details about supported hardware, firmware, operating systems, and drivers, plus any additional configuration notes. View results on screen or export them to Excel.
External storage systems
Lenovo offers the ThinkSystem DE Series and ThinkSystem DM Series external storage systems for high-performance storage. See the DE Series and DM Series product guides for specific controller models, expansion enclosures and configuration options:
- ThinkSystem DE Series Storage
https://lenovopress.com/storage/thinksystem/de-series#rt=product-guide - ThinkSystem DM Series Storage
https://lenovopress.com/storage/thinksystem/dm-series#rt=product-guide - ThinkSystem DG Series Storage
https://lenovopress.com/storage/thinksystem/dg-series#rt=product-guide
External backup units
The following table lists the external backup options that are offered by Lenovo that can be used in Lenovo FC SAN solutions.
Note: Information provided in this section is for ordering reference purposes only. End-to-end LTO Ultrium configuration support for a particular tape backup unit must be verified through the System Storage Interoperation Center (SSIC):
http://www.ibm.com/systems/support/storage/ssic
For more information, see the list of Product Guides in the Tape Autoloaders and Libraries category:
https://lenovopress.com/storage/tape/library
Rack cabinets
The following table lists the supported rack cabinets.
For specifications about these racks, see the Lenovo Rack Cabinet Reference, available from:
https://lenovopress.com/lp1287-lenovo-rack-cabinet-reference
For more information, see the list of Product Guides in the Rack cabinets category:
https://lenovopress.com/servers/options/racks
Power distribution units
The following table lists the power distribution units (PDUs) that are offered by Lenovo.
For more information, see the Lenovo Press documents in the PDU category:
https://lenovopress.com/servers/options/pdu
Uninterruptible power supply units
The following table lists the uninterruptible power supply (UPS) units that are offered by Lenovo.
† Only available in China and the Asia Pacific market.
For more information, see the list of Product Guides in the UPS category:
https://lenovopress.com/servers/options/ups
Seller training courses
The following sales training courses are offered for employees and partners (login required). Courses are listed in date order.
-
Family Portfolio: Storage Networking
2024-10-14 | 15 minutes | Employees and Partners
DetailsFamily Portfolio: Storage NetworkingThis course will provide you an overview of the Storage Networking family. After completing this course, you should be able to identify the products in the Storage Networking portfolio and their features, describe product family benefits, and recognize when a specific product should be used.
Published: 2024-10-14
Length: 15 minutesStart the training:
Employee link: Grow@Lenovo
Partner link: Lenovo Partner Learning -
Partner Technical Webinar - Fibre Channel Market Tranistions
2024-10-08 | 60 minutes | Employees and Partners
DetailsPartner Technical Webinar - Fibre Channel Market Tranistionsin this 60-minute replay, there were two topics. Mike Easterly, Fibre Channel Technical Sales Executive for Broadcom, reviewed the Fibre Channel offerings. He described then need to focus on Gen 7 over Gen5 & Gen6. He described the many security features of Fibre Channel and why Fibre Channel is the gold standard of storage networking. Herb Ducey, Lenovo Storage Product Manager concluded with updates on the storage product line including DM Series, DE Series and D3284 updates.
Published: 2024-10-08
Length: 60 minutesStart the training:
Employee link: Grow@Lenovo
Partner link: Lenovo Partner Learning -
Lenovo Data Center Product Portfolio
2024-05-29 | 20 minutes | Employees and Partners
DetailsLenovo Data Center Product PortfolioThis course introduces the Lenovo data center portfolio, and covers servers, storage, storage networking, and software-defined infrastructure products. After completing this course about Lenovo data center products, you will be able to identify product types within each data center family, describe Lenovo innovations that this product family or category uses, and recognize when a specific product should be selected.
Published: 2024-05-29
Length: 20 minutesStart the training:
Employee link: Grow@Lenovo
Partner link: Lenovo Partner Learning -
Simplify Selling Fibre Channel Storage Solutions
2024-04-23 | 45 minutes | Employees and Partners
DetailsSimplify Selling Fibre Channel Storage SolutionsIn this session we look at the benefits of Fibre Channel and the benefits to you and your customers of bundling FC networking with your storage arrays.
Published: 2024-04-23
Plus, we will take a closer look at some of the changes Lenovo has made to the Data Center Solutions Configurator to help you and the clients build bundled FC solutions.
Course Objectives:
1. Learn the benefits of Fibre Channel
2. Understand the benefits of bundling FC networking with your storage arrays
3. Discover the latest updates in DCSC (Data Center Solutions Configurator)
Length: 45 minutesStart the training:
Employee link: Grow@Lenovo
Partner link: Lenovo Partner Learning -
Partner Technical Webinar - Fibre Channel and DG Updates
2024-04-23 | 60 minutes | Employees and Partners
DetailsPartner Technical Webinar - Fibre Channel and DG UpdatesIn this 60-minute replay, Mike Easterly, Broadcom, reviewed Lenovo solutions for Fibre Channel (FC) including Emulex FC Adapters and Brocade FC switches. Next, Mark Clayton, Lenovo Storage Architect, reviewed the lasted on the Data Management portfolio with updates on DG, HS350x Ready Nodes and Data Protection.
Published: 2024-04-23
Length: 60 minutesStart the training:
Employee link: Grow@Lenovo
Partner link: Lenovo Partner Learning -
VTT Data Management How to sell storage - April 2024
2024-04-10 | 60 minutes | Employees Only
DetailsVTT Data Management How to sell storage - April 2024In this course, you will know:
Published: 2024-04-10
- Why do we sell storage?
- What are the basics you need to get an opportunity rolling?
- Why Lenovo for Storage?
- What is happening in the market today?
- How to determine traction?
Length: 60 minutesStart the training:
Employee link: Grow@Lenovo
Related publications and links
For more information, see the following resources:
- Interactive 3D Tour for the DB630S:
https://lenovopress.com/LP1186 - Lenovo ThinkSystem DB630S FC SAN Switch product publications
http://datacentersupport.lenovo.com- Hardware Installation Guide
- Fabric OS Administration Guide
- Fabric OS Extension Configuration Guide
- Fabric OS Troubleshooting and Diagnostics Guide
- Fabric OS Command Reference
- Fabric OS Message Reference
- Fabric OS MIB Reference
- Web Tools Administration Guide
- Flow Vision Configuration Guide
- Monitoring and Alerting Policy Suite Configuration Guide
- Lenovo Data Center Support for the ThinkSystem DB630S FC SAN Switch:
http://datacentersupport.lenovo.com - Benefits of an End-to-End NVMe over FC Solution with Lenovo ThinkSystem
http://lenovopress.com/lp0955
Trademarks
Lenovo and the Lenovo logo are trademarks or registered trademarks of Lenovo in the United States, other countries, or both. A current list of Lenovo trademarks is available on the Web at https://www.lenovo.com/us/en/legal/copytrade/.
The following terms are trademarks of Lenovo in the United States, other countries, or both:
Lenovo®
ThinkAgile®
ThinkSystem®
The following terms are trademarks of other companies:
Microsoft® and Excel® are trademarks of Microsoft Corporation in the United States, other countries, or both.
Other company, product, or service names may be trademarks or service marks of others.
Configure and Buy
Full Change History
Changes in the May 7, 2024 update:
- The following have been withdrawn under Transceivers and cables section:
- Brocade 10Gb FC SWL SFP+ Transceiver, 00YH933
- Brocade 10Gb FC LWL SFP+ Transceiver, 00YH929
- Brocade 16Gb SWL SFP+ Optical Transceiver, 88Y6393
- Brocade 32Gb LWL SFP+ Transceiver, 01KN793
- Brocade 32Gb LWL SFP+ Transceiver (8-pack), 01KN799
- Brocade SAN switch, B300
- The following have been added under Transceivers and cables section:
- Brocade SAN switch, DB730S
- Transceiver, 4x 32 Gb FC SWL QSFP+, 4M27A65422
- 16 Gb FC LWL SFP+, 4M27A65413, 4M27A65414
Changes in the October 13, 2022 update:
- The following transceiver has been withdrawn - Transceivers and cables section:
- 01KN795 AVGE Brocade 32Gb LWL SFP+ Transceiver
- 00MY770 ASK3 Brocade 16Gb 25km ELWL SFP+ Transceiver
- The following interface is withdrawn:
- EZSwitch management interface
Changes in the August 15, 2022 update:
- New updates in - System specifications section
- Fabric services
- Supported management software
- Security features
- Diagnostics
- New updates in - Enterprise Bundles and Integrated Routing features section
- Fabric Vision (FV)
Changes in the July 26, 2022 update:
- New 32Gb ELWL transceiver - Transceivers and cables section:
- Brocade Secure 32Gb ELWL SFP+ V2 Transceiver (25 km), 4M27A65431
Changes in the February 1, 2022 update:
- The following transceiver has been withdrawn - Transceivers and cables section:
- Brocade 128Gb (4x32Gbps) 2KM QSFP+ Transceiver, 4M27A09986
Changes in the January 4, 2022 update:
- The following Port On-Demand upgrades have been withdrawn - Port activation licenses section:
- Lenovo DB620S 12-Port License (No Transceivers), 7S0C000EWW
- Lenovo DB620S QSFP+ Port License (No Transceivers), 7S0C000FWW
Changes in the June 29, 2021 update:
- The following transceiver is withdrawn from marketing - Transceivers and cables section:
- Brocade 32GB SWL SFP+ Transceiver, 01KN789
Changes in the June 3, 2021 update:
- Model 7D1SCTO1WW is now withdrawn from marketing - Models section
Changes in the May 11, 2021 update:
- The following transceiver is now withdrawn from marketing - Transceivers and cables section:
- Brocade 16GB 10KM LW SFP Transceiver, 00MY768
Changes in the March 13, 2021 update:
- The following transceivers are now withdrawn from marketing - Transceivers and cables section:
- Brocade 10G FC SWL SFP+, 00YH933
- Brocade 10G FC LWL SFP+, 00YH929
- Brocade 128GB (4x32Gbps) SWL QSFP+ Transceiver v2, 4M27A08820
Changes in the January 26, 2021 update:
- New Brocade Secure transceivers - 128Gb, 32Gb, 16Gb and 10Gb - Transceivers and cables section
Changes in the October 20, 2020 update:
- Models CTO2 and CTO3 (7D1SCTO2WW and 7D1SCTO3WW) are now withdrawn from marketing - Models section
- Model CTO5 ships with 48 transceivers - Port activation licenses section
Changes in the July 14, 2020 update:
- Added Models CTO5 and CTO6
- Added Brocade SANnav Global View and Mgmt Portal Base and Enterprise Editions 5YR License options
- Updated Fibre Channel SAN switches: Added models announced July 14, 2020
First published: 2 July 2019
Course Detail
Employees Only Content
The content in this document with a is only visible to employees who are logged in. Logon using your Lenovo ITcode and password via Lenovo single-signon (SSO).
The author of the document has determined that this content is classified as Lenovo Internal and should not be normally be made available to people who are not employees or contractors. This includes partners, customers, and competitors. The reasons may vary and you should reach out to the authors of the document for clarification, if needed. Be cautious about sharing this content with others as it may contain sensitive information.
Any visitor to the Lenovo Press web site who is not logged on will not be able to see this employee-only content. This content is excluded from search engine indexes and will not appear in any search results.
For all users, including logged-in employees, this employee-only content does not appear in the PDF version of this document.
This functionality is cookie based. The web site will normally remember your login state between browser sessions, however, if you clear cookies at the end of a session or work in an Incognito/Private browser window, then you will need to log in each time.
If you have any questions about this feature of the Lenovo Press web, please email David Watts at dwatts@lenovo.com.