skip to main content

ThinkSystem Kioxia CM6-V Mainstream NVMe PCIe 4.0 x4 SSDs

Product Guide (withdrawn product)

Home
Top
Author
Updated
31 Jul 2023
Form Number
LP1361
PDF size
19 pages, 197 KB

Abstract

The ThinkSystem Kioxia CM6-V Mainstream NVMe PCIe 4.0 x4 solid-state drives (SSDs) in capacities up to 6.4 TB are advanced data center SSDs optimized for mixed read-write performance, endurance, and strong data protection for Lenovo servers. With a PCIe 4.0 x4 interface, they are designed for greater performance and endurance in a cost-effective design, and to support a broader set of workloads.

This product guide provides essential presales information to understand the Mainstream NVMe PCIe SSD offerings and their key features, specifications, and compatibility. This guide is intended for technical specialists, sales specialists, sales engineers, IT architects, and other IT professionals who want to learn more about the SSDs and consider their use in IT solutions.

Withdrawn from marketing: The drives described in this product guide are withdrawn from marketing.

Change History

Changes in the July 31, 2023 update:

  • The drives described in this product guide are withdrawn from marketing.

Introduction

The ThinkSystem Kioxia CM6-V Mainstream NVMe PCIe 4.0 x4 solid-state drives (SSDs) in capacities up to 6.4 TB are advanced data center SSDs optimized for mixed read-write performance, endurance, and strong data protection for Lenovo servers. With a PCIe 4.0 x4 interface, they are designed for greater performance and endurance in a cost-effective design, and to support a broader set of workloads.

ThinkSystem Kioxia CM6-V Mainstream NVMe PCIe 4.0 x4 SSDs

Figure 1. ThinkSystem Kioxia CM6-V Mainstream NVMe PCIe 4.0 x4 SSD

Did you know?

The Kioxia CM6 drives have a PCIe 4.0 (Gen 4) host interface, where sequential performance is doubled over the PCIe 3.0 host interface. The drives are also fully compatible with a PCIe 3.0 host interface providing optimal performance and enabling compatibility across server families.

NVMe (Non-Volatile Memory Express) is a technology that overcomes SAS/SATA SSD performance limitations by optimizing hardware and software to take full advantage of flash technology. The use of NVMe drives means data is transferred more efficiently from the processor to the drives compared to the legacy Advance Host Controller Interface (AHCI) stack, thereby reducing latency and overhead. These SSDs connect directly to the processor via the PCIe bus, further reducing latency and TCO.

Part number information

The following table lists the part numbers and feature codes for ThinkSystem servers.

Withdrawn from marketing: The drives described in this product guide are withdrawn from marketing.

Table 1. Part numbers and feature codes for ThinkSystem
Part
number
Feature
code
Description
2.5-inch hot-swap drives
4XB7A64175 BE03 ThinkSystem U.3 Kioxia CM6-V 800GB Mainstream NVMe PCIe 4.0 x4 Hot Swap SSD
4XB7A17112 B96Z ThinkSystem U.3 Kioxia CM6-V 1.6TB Mainstream NVMe PCIe4.0 x4 Hot Swap SSD
4XB7A17113 B96T ThinkSystem U.3 Kioxia CM6-V 3.2TB Mainstream NVMe PCIe4.0 x4 Hot Swap SSD
4XB7A17114 B96P ThinkSystem U.3 Kioxia CM6-V 6.4TB Mainstream NVMe PCIe4.0 x4 Hot Swap SSD
3.5-inch hot-swap drives
4XB7A64176 BE04 ThinkSystem 3.5" Kioxia CM6-V 800GB Mainstream NVMe PCIe 4.0 x4 Hot Swap SSD
4XB7A17115 B96V ThinkSystem 3.5" Kioxia CM6-V 1.6TB Mainstream NVMe PCIe4.0 x4 Hot Swap SSD
4XB7A17116 B96K ThinkSystem 3.5" Kioxia CM6-V 3.2TB Mainstream NVMe PCIe4.0 x4 Hot Swap SSD
4XB7A17117 B96W ThinkSystem 3.5" Kioxia CM6-V 6.4TB Mainstream NVMe PCIe4.0 x4 Hot Swap SSD
Trayless drives
4XB7A63069 BCNB ThinkSystem Kioxia CM6-V 2.5" 15mm 1.6TB Mainstream NVMe PCIe 4.0 x4 Trayless SSD
4XB7A63070 BCN9 ThinkSystem Kioxia CM6-V 2.5" 15mm 3.2TB Mainstream NVMe PCIe 4.0 x4 Trayless SSD

The part numbers include the following items:

  • One 2.5-inch solid-state drive
  • 2.5-inch or 3.5-inch hot-swap tray (hot-swap drives only)
  • Documentation

Features

Non-Volatile Memory Express (NVMe) is PCIe high performance SSD technology that provides high I/O throughput and low latency. NVMe interfaces remove SAS/SATA bottlenecks and unleash all of the capabilities of contemporary NAND flash memory. Each NVMe PCI SSD has direct PCIe x4 connection, which provides at significantly greater bandwidth and lower latency than SATA/SAS-based SSD solutions. NVMe drives are also optimized for heavy multi-threaded workloads by using internal parallelism and many other improvements, such as enlarged I/O queues.

The ThinkSystem Kioxia CM6-V Mainstream NVMe SSDs have the following features:

  • Two form factors:
    • 2.5-inch (U.3, which is backward compatible with U.2) hot-swap drive tray
    • 3.5-inch hot-swap drive tray
  • Based on the Kioxia KCM61VUL drives (formerly Toshiba)
  • 96-layer BiCS FLASH 3D TLC memory
  • 3 drive-write-per-day (DWPD) SSD for mixed read-write workloads
  • PCIe 4.0 x4 host connection for each NVMe drive, resulting in up to 6.9 GBps overall throughput.
  • Full Power-Loss-Protection and End-to-End Data Protection
  • Low power consumption (maximum 20 W)

Mainstream SSDs and Performance SSDs have similar read and write IOPS performance, but the key difference between them is their endurance (or lifetime) (that is, how long they can perform write operations because SSDs have a finite number of program/erase (P/E) cycles).  Mainstream SSDs have a better cost/IOPS ratio but lower endurance compared to Performance SSDs. SSD write endurance is typically measured by the number of program/erase (P/E) cycles that the drive incurs over its lifetime, listed as the total bytes of written data (TBW) in the device specification.

The TBW value assigned to a solid-state device is the total bytes of written data (based on the number of P/E cycles) that a drive can be guaranteed to complete (% of remaining P/E cycles = % of remaining TBW). Reaching this limit does not cause the drive to immediately fail. It simply denotes the maximum number of writes that can be guaranteed. A solid-state device will not fail upon reaching the specified TBW. At some point based on manufacturing variance margin, after surpassing the TBW value, the drive will reach the end-of-life point, at which the drive will go into a read-only mode.

Because of such behavior by Mainstream solid-state drives, careful planning must be done to use them only in mixed read-write environments to ensure that the TBW of the drive will not be exceeded before the required life expectancy.

For example, the 3.2 TB drive has an endurance of 17,520 TB of total bytes written (TBW). This means that for full operation over five years, write workload must be limited to no more than 9.6 TB of writes per day, which is equivalent to 3.0 full drive writes per day (DWPD). For the device to last three years, the drive write workload must be limited to no more than 16 TB of writes per day, which is equivalent to 5.0 full drive writes per day.

Technical specifications

The following table presents technical specifications for the ThinkSystem Kioxia CM6-V Mainstream NVMe SSDs.

Table 2. Technical specifications
Feature 800 GB drive 1.6 TB drive 3.2 TB drive 6.4 TB drive
Host interface PCIe 4.0 x4 PCIe 4.0 x4 PCIe 4.0 x4 PCIe 4.0 x4
Capacity 800 GB 1.6 TB 3.2 TB 6.4 TB
SED encryption None None None None
Endurance (total bytes written) 4,380 TB 8,760 TB 17,520 TB 35,040 TB
Endurance (drive writes per day for 5 years) 3.0 DWPD 3.0 DWPD 3.0 DWPD 3.0 DWPD
Data reliability (UBER) < 1 in 1017 bits read < 1 in 1017 bits read < 1 in 1017 bits read < 1 in 1017 bits read
MTBF 2,500,000 hours 2,500,000 hours 2,500,000 hours 2,500,000 hours
IOPS reads (4 KB blocks, PCIe 4.0) 880,000 1,300,000 1,400,000 1,400,000
IOPS writes (4 KB blocks, PCIe 4.0) 100,000 215,000 350,000 325,000
Sequential read rate (128 KB blocks, PCIe 4.0) 6900 MBps 6900 MBps 6900 MBps 6900 MBps
Sequential write rate (128 KB blocks, PCIe 4.0) 1400 MBps 2800 MBps 4200 MBps 4000 MBps
Latency (random read) 90 µs 90 µs 90 µs 90 µs
Latency (random write) 10 µs 10 µs 10 µs 10 µs
Maximum power 14 W 16 W 19 W 20 W

Server support

The following tables list the ThinkSystem servers that are compatible.

Table 3. Server support (Part 1 of 4)
Part Number Description AMD V3 2S Intel V3/V4 4S 8S Intel V3 Multi Node V3/V4 1S V3
SR635 V3 (7D9H / 7D9G)
SR655 V3 (7D9F / 7D9E)
SR645 V3 (7D9D / 7D9C)
SR665 V3 (7D9B / 7D9A)
ST650 V3 (7D7B / 7D7A)
SR630 V3 (7D72 / 7D73)
SR650 V3 (7D75 / 7D76)
SR630 V4 (7DG8 / 7DG9)
SR850 V3 (7D97 / 7D96)
SR860 V3 (7D94 / 7D93)
SR950 V3 (7DC5 / 7DC4)
SD535 V3 (7DD8 / 7DD1)
SD530 V3 (7DDA / 7DD3)
SD550 V3 (7DD9 / 7DD2)
ST45 V3 (7DH4 / 7DH5)
ST50 V3 (7DF4 / 7DF3)
ST250 V3 (7DCF / 7DCE)
SR250 V3 (7DCM / 7DCL)
2.5-inch hot-swap drives
4XB7A64175 ThinkSystem U.3 Kioxia CM6-V 800GB Mainstream NVMe PCIe 4.0 x4 Hot Swap SSD N N N N N N N N N N N N N N N N N N
4XB7A17112 ThinkSystem U.3 Kioxia CM6-V 1.6TB Mainstream NVMe PCIe4.0 x4 Hot Swap SSD N N N N N N N N N N N N N N N N N N
4XB7A17113 ThinkSystem U.3 Kioxia CM6-V 3.2TB Mainstream NVMe PCIe4.0 x4 Hot Swap SSD N N N N N N N N N N N N N N N N N N
4XB7A17114 ThinkSystem U.3 Kioxia CM6-V 6.4TB Mainstream NVMe PCIe4.0 x4 Hot Swap SSD N N N N N N N N N N N N N N N N N N
3.5-inch hot-swap drives
4XB7A64176 ThinkSystem 3.5" Kioxia CM6-V 800GB Mainstream NVMe PCIe 4.0 x4 Hot Swap SSD N N N N N N N N N N N N N N N N N N
4XB7A17115 ThinkSystem 3.5" Kioxia CM6-V 1.6TB Mainstream NVMe PCIe4.0 x4 Hot Swap SSD N N N N N N N N N N N N N N N N N N
4XB7A17116 ThinkSystem 3.5" Kioxia CM6-V 3.2TB Mainstream NVMe PCIe4.0 x4 Hot Swap SSD N N N N N N N N N N N N N N N N N N
4XB7A17117 ThinkSystem 3.5" Kioxia CM6-V 6.4TB Mainstream NVMe PCIe4.0 x4 Hot Swap SSD N N N N N N N N N N N N N N N N N N
Trayless drives
4XB7A63069 ThinkSystem Kioxia CM6-V 2.5" 15mm 1.6TB Mainstream NVMe PCIe 4.0 x4 Trayless SSD N N N N N N N N N N N N N N N N N N
4XB7A63070 ThinkSystem Kioxia CM6-V 2.5" 15mm 3.2TB Mainstream NVMe PCIe 4.0 x4 Trayless SSD N N N N N N N N N N N N N N N N N N
Table 4. Server support (Part 2 of 4)
Part Number Description GPU Rich Edge Super Computing 1S Intel V2
SR670 V2 (7Z22 / 7Z23)
SR675 V3 (7D9Q / 7D9R)
SR680a V3 (7DHE)
SR685a V3 (7DHC)
SR780a V3 (7DJ5)
SE350 (7Z46 / 7D1X)
SE350 V2 (7DA9)
SE360 V2 (7DAM)
SE450 (7D8T)
SE455 V3 (7DBY)
SC750 V4 (7DDJ)
SC777 V4 (7DKA)
SD665 V3 (7D9P)
SD665-N V3 (7DAZ)
SD650 V3 (7D7M)
SD650-I V3 (7D7L)
SD650-N V3 (7D7N)
ST50 V2 (7D8K / 7D8J)
ST250 V2 (7D8G / 7D8F)
SR250 V2 (7D7R / 7D7Q)
2.5-inch hot-swap drives
4XB7A64175 ThinkSystem U.3 Kioxia CM6-V 800GB Mainstream NVMe PCIe 4.0 x4 Hot Swap SSD Y N N N N N N N N N N N N N N N N N N N
4XB7A17112 ThinkSystem U.3 Kioxia CM6-V 1.6TB Mainstream NVMe PCIe4.0 x4 Hot Swap SSD Y N N N N N N N N N N N N N N N N N N N
4XB7A17113 ThinkSystem U.3 Kioxia CM6-V 3.2TB Mainstream NVMe PCIe4.0 x4 Hot Swap SSD Y N N N N N N N N N N N N N N N N N N N
4XB7A17114 ThinkSystem U.3 Kioxia CM6-V 6.4TB Mainstream NVMe PCIe4.0 x4 Hot Swap SSD Y N N N N N N N N N N N N N N N N N N N
3.5-inch hot-swap drives
4XB7A64176 ThinkSystem 3.5" Kioxia CM6-V 800GB Mainstream NVMe PCIe 4.0 x4 Hot Swap SSD N N N N N N N N N N N N N N N N N N N N
4XB7A17115 ThinkSystem 3.5" Kioxia CM6-V 1.6TB Mainstream NVMe PCIe4.0 x4 Hot Swap SSD N N N N N N N N N N N N N N N N N N N N
4XB7A17116 ThinkSystem 3.5" Kioxia CM6-V 3.2TB Mainstream NVMe PCIe4.0 x4 Hot Swap SSD N N N N N N N N N N N N N N N N N N N N
4XB7A17117 ThinkSystem 3.5" Kioxia CM6-V 6.4TB Mainstream NVMe PCIe4.0 x4 Hot Swap SSD N N N N N N N N N N N N N N N N N N N N
Trayless drives
4XB7A63069 ThinkSystem Kioxia CM6-V 2.5" 15mm 1.6TB Mainstream NVMe PCIe 4.0 x4 Trayless SSD N N N N N N N N N N N N N N N N N N N N
4XB7A63070 ThinkSystem Kioxia CM6-V 2.5" 15mm 3.2TB Mainstream NVMe PCIe 4.0 x4 Trayless SSD N N N N N N N N N N N N N N N N N N N N
Table 5. Server support (Part 3 of 4)
Part Number Description 2S Intel V2 AMD V1 Dense V2 4S V2 8S 4S V1
ST650 V2 (7Z75 / 7Z74)
SR630 V2 (7Z70 / 7Z71)
SR650 V2 (7Z72 / 7Z73)
SR635 (7Y98 / 7Y99)
SR655 (7Y00 / 7Z01)
SR655 Client OS
SR645 (7D2Y / 7D2X)
SR665 (7D2W / 7D2V)
SD630 V2 (7D1K)
SD650 V2 (7D1M)
SD650-N V2 (7D1N)
SN550 V2 (7Z69)
SR850 V2 (7D31 / 7D32)
SR860 V2 (7Z59 / 7Z60)
SR950 (7X11 / 7X12)
SR850 (7X18 / 7X19)
SR850P (7D2F / 2D2G)
SR860 (7X69 / 7X70)
2.5-inch hot-swap drives
4XB7A64175 ThinkSystem U.3 Kioxia CM6-V 800GB Mainstream NVMe PCIe 4.0 x4 Hot Swap SSD N Y Y Y Y Y Y Y N N N N Y Y Y Y Y Y
4XB7A17112 ThinkSystem U.3 Kioxia CM6-V 1.6TB Mainstream NVMe PCIe4.0 x4 Hot Swap SSD N Y Y Y Y Y Y Y N N N Y Y Y Y Y Y Y
4XB7A17113 ThinkSystem U.3 Kioxia CM6-V 3.2TB Mainstream NVMe PCIe4.0 x4 Hot Swap SSD N Y Y Y Y Y Y Y N N N N Y Y Y Y Y Y
4XB7A17114 ThinkSystem U.3 Kioxia CM6-V 6.4TB Mainstream NVMe PCIe4.0 x4 Hot Swap SSD N Y Y Y Y Y Y Y N N N N Y Y Y Y Y Y
3.5-inch hot-swap drives
4XB7A64176 ThinkSystem 3.5" Kioxia CM6-V 800GB Mainstream NVMe PCIe 4.0 x4 Hot Swap SSD N Y Y N N N Y Y N N N N N N N N N N
4XB7A17115 ThinkSystem 3.5" Kioxia CM6-V 1.6TB Mainstream NVMe PCIe4.0 x4 Hot Swap SSD N Y Y N N N Y Y N N N N N N N N N N
4XB7A17116 ThinkSystem 3.5" Kioxia CM6-V 3.2TB Mainstream NVMe PCIe4.0 x4 Hot Swap SSD N Y Y N N N Y Y N N N N N N N N N N
4XB7A17117 ThinkSystem 3.5" Kioxia CM6-V 6.4TB Mainstream NVMe PCIe4.0 x4 Hot Swap SSD N Y Y N N N Y Y N N N N N N N N N N
Trayless drives
4XB7A63069 ThinkSystem Kioxia CM6-V 2.5" 15mm 1.6TB Mainstream NVMe PCIe 4.0 x4 Trayless SSD N N N N N N N N N Y Y N N N N N N N
4XB7A63070 ThinkSystem Kioxia CM6-V 2.5" 15mm 3.2TB Mainstream NVMe PCIe 4.0 x4 Trayless SSD N N N N N N N N N Y Y N N N N N N N
Table 6. Server support (Part 4 of 4)
Part Number Description 1S Intel V1 2S Intel V1 Dense V1
ST50 (7Y48 / 7Y50)
ST250 (7Y45 / 7Y46)
SR150 (7Y54)
SR250 (7Y52 / 7Y51)
ST550 (7X09 / 7X10)
SR530 (7X07 / 7X08)
SR550 (7X03 / 7X04)
SR570 (7Y02 / 7Y03)
SR590 (7X98 / 7X99)
SR630 (7X01 / 7X02)
SR650 (7X05 / 7X06)
SR670 (7Y36 / 7Y37)
SD530 (7X21)
SD650 (7X58)
SN550 (7X16)
SN850 (7X15)
2.5-inch hot-swap drives
4XB7A64175 ThinkSystem U.3 Kioxia CM6-V 800GB Mainstream NVMe PCIe 4.0 x4 Hot Swap SSD N N N N N N N Y Y Y Y N Y N Y Y
4XB7A17112 ThinkSystem U.3 Kioxia CM6-V 1.6TB Mainstream NVMe PCIe4.0 x4 Hot Swap SSD N N N N N N N Y Y Y Y N Y N Y Y
4XB7A17113 ThinkSystem U.3 Kioxia CM6-V 3.2TB Mainstream NVMe PCIe4.0 x4 Hot Swap SSD N N N N N N N Y Y Y Y N Y N Y Y
4XB7A17114 ThinkSystem U.3 Kioxia CM6-V 6.4TB Mainstream NVMe PCIe4.0 x4 Hot Swap SSD N N N N N N N Y Y Y Y N Y N Y Y
3.5-inch hot-swap drives
4XB7A64176 ThinkSystem 3.5" Kioxia CM6-V 800GB Mainstream NVMe PCIe 4.0 x4 Hot Swap SSD N N N N N N N N N Y Y N N N N N
4XB7A17115 ThinkSystem 3.5" Kioxia CM6-V 1.6TB Mainstream NVMe PCIe4.0 x4 Hot Swap SSD N N N N N N N N N Y Y N N N N N
4XB7A17116 ThinkSystem 3.5" Kioxia CM6-V 3.2TB Mainstream NVMe PCIe4.0 x4 Hot Swap SSD N N N N N N N N N Y Y N N N N N
4XB7A17117 ThinkSystem 3.5" Kioxia CM6-V 6.4TB Mainstream NVMe PCIe4.0 x4 Hot Swap SSD N N N N N N N N N Y Y N N N N N
Trayless drives
4XB7A63069 ThinkSystem Kioxia CM6-V 2.5" 15mm 1.6TB Mainstream NVMe PCIe 4.0 x4 Trayless SSD N N N N N N N N N N N N N N N N
4XB7A63070 ThinkSystem Kioxia CM6-V 2.5" 15mm 3.2TB Mainstream NVMe PCIe 4.0 x4 Trayless SSD N N N N N N N N N N N N N N N N

Storage controller support

NVMe PCIe SSDs require a NVMe drive backplane and some form of PCIe connection to processors. PCIe connections can take the form of either an adapter (PCIe Interposer or PCIe extender/switch adapter) or simply a cable that connects to an onboard NVMe connector.

PCIe 3.0 support: The Kioxia CM6-V drives offer a PCIe 4.0 host interface, however they are backward compatible with a PCIe 3.0 host interface. Note however that servers with a PCIe 3.0 host interface will not see the same performance levels (especially sequential read and write rates). ThinkSystem NVMe switch adapters also provide a PCIe 3.0 host interface to attached drives.

Consult the relevant server product guide for details about required components for NVMe drive support.

Operating system support

The following table lists the supported operating systems.

Tip: These tables are automatically generated based on data from Lenovo ServerProven.

Table 7. Operating system support for ThinkSystem U.3 Kioxia CM6-V 1.6TB Mainstream NVMe PCIe 4.0 x4 Hot Swap SSD, 4XB7A17112 (Part 1 of 3)
Operating systems
SD630 V2
SN550 V2
SR630 V2
SR650 V2
SR670 V2
SR850 V2
SR860 V2
SR635
SR645
SR655
SR665
Microsoft Windows 10 N N N N N N N N N Y 2 N
Microsoft Windows 11 N N N N N N N N N Y 2 N
Microsoft Windows Server 2012 R2 N N N N N N N N N N N
Microsoft Windows Server 2016 Y Y Y Y Y Y Y Y Y Y Y
Microsoft Windows Server 2019 Y Y Y Y Y Y Y Y Y Y Y
Microsoft Windows Server 2022 Y Y Y Y Y Y Y Y Y Y Y
Microsoft Windows Server 2025 N N Y Y Y Y Y N Y N Y
Red Hat Enterprise Linux 6.10 N N N N N N N N N N N
Red Hat Enterprise Linux 6.9 N N N N N N N N N N N
Red Hat Enterprise Linux 7.3 N N N N N N N N N N N
Red Hat Enterprise Linux 7.4 N N N N N N N N N N N
Red Hat Enterprise Linux 7.5 N N N N N N N N N N N
Red Hat Enterprise Linux 7.6 N N N N N N N Y 1 Y 1 Y 1 Y 1
Red Hat Enterprise Linux 7.7 N N N N N N N Y 1 Y 1 Y 1 Y 1
Red Hat Enterprise Linux 7.8 N N N N N N N Y 1 Y 1 Y 1 Y 1
Red Hat Enterprise Linux 7.9 Y Y Y Y Y Y Y Y 1 Y 1 Y 1 Y 1
Red Hat Enterprise Linux 8.0 N N N N N N N Y 1 N Y 1 N
Red Hat Enterprise Linux 8.1 N N N N N N N Y 1 Y 1 Y 1 Y 1
Red Hat Enterprise Linux 8.10 Y Y Y Y Y Y Y Y Y Y Y
Red Hat Enterprise Linux 8.2 Y Y Y Y Y Y Y Y 1 Y 1 Y 1 Y 1
Red Hat Enterprise Linux 8.3 Y Y Y Y Y Y Y Y Y Y Y
Red Hat Enterprise Linux 8.4 Y Y Y Y Y Y Y Y Y Y Y
Red Hat Enterprise Linux 8.5 Y Y Y Y Y Y Y Y Y Y Y
Red Hat Enterprise Linux 8.6 Y Y Y Y Y Y Y Y Y Y Y
Red Hat Enterprise Linux 8.7 Y Y Y Y Y Y Y Y Y Y Y
Red Hat Enterprise Linux 8.8 Y Y Y Y Y Y Y Y Y Y Y
Red Hat Enterprise Linux 8.9 Y Y Y Y Y Y Y Y Y Y Y
Red Hat Enterprise Linux 9.0 Y Y Y Y Y Y Y Y Y Y Y
Red Hat Enterprise Linux 9.1 Y Y Y Y Y Y Y Y Y Y Y
Red Hat Enterprise Linux 9.2 Y Y Y Y Y Y Y Y Y Y Y
Red Hat Enterprise Linux 9.3 Y Y Y Y Y Y Y Y Y Y Y
Red Hat Enterprise Linux 9.4 Y Y Y Y Y Y Y Y Y Y Y
Red Hat Enterprise Linux 9.5 Y Y Y Y Y Y Y Y Y Y Y
SUSE Linux Enterprise Server 11 SP4 N N N N N N N N N N N
SUSE Linux Enterprise Server 12 SP2 N N N N N N N N N N N
SUSE Linux Enterprise Server 12 SP2 with Xen N N N N N N N N N N N
SUSE Linux Enterprise Server 12 SP3 N N N N N N N N N N N
SUSE Linux Enterprise Server 12 SP3 with Xen N N N N N N N N N N N
SUSE Linux Enterprise Server 12 SP4 N N N N N N N Y 1 N Y 1 N
SUSE Linux Enterprise Server 12 SP4 with Xen N N N N N N N Y 1 N Y 1 N
SUSE Linux Enterprise Server 12 SP5 Y Y Y Y Y Y Y Y Y Y Y
SUSE Linux Enterprise Server 12 SP5 with Xen Y Y Y Y Y Y Y Y Y Y Y
SUSE Linux Enterprise Server 15 N N N N N N N N N N N
SUSE Linux Enterprise Server 15 SP1 N N N N N N N Y 1 Y 1 Y 1 Y 1
SUSE Linux Enterprise Server 15 SP1 with Xen N N N N N N N Y 1 Y 1 Y 1 Y 1
SUSE Linux Enterprise Server 15 SP2 Y Y Y Y Y Y Y Y Y Y Y
SUSE Linux Enterprise Server 15 SP2 with Xen Y Y Y Y Y Y Y Y Y Y Y
SUSE Linux Enterprise Server 15 SP3 Y Y Y Y Y Y Y Y Y Y Y
SUSE Linux Enterprise Server 15 SP3 with Xen Y Y Y Y Y Y Y Y Y Y Y
SUSE Linux Enterprise Server 15 SP4 Y Y Y Y Y Y Y Y Y Y Y
SUSE Linux Enterprise Server 15 SP4 with Xen Y Y Y Y Y Y Y Y Y Y Y
SUSE Linux Enterprise Server 15 SP5 Y Y Y Y Y Y Y Y Y Y Y
SUSE Linux Enterprise Server 15 SP5 with Xen Y Y Y Y Y Y Y Y Y Y Y
SUSE Linux Enterprise Server 15 SP6 N Y Y Y Y Y Y Y Y Y Y
SUSE Linux Enterprise Server 15 with Xen N N N N N N N N N N N
Ubuntu 18.04.5 LTS Y Y Y Y Y N N N N N N
Ubuntu 20.04 LTS N N Y Y N N N N N N N
Ubuntu 22.04 LTS Y Y Y Y Y Y Y Y Y Y Y
Ubuntu 24.04 LTS Y Y Y Y Y Y Y Y Y Y Y
VMware vSphere Hypervisor (ESXi) 6.5 N N N N N N N N N N N
VMware vSphere Hypervisor (ESXi) 6.5 U1 N N N N N N N N N N N
VMware vSphere Hypervisor (ESXi) 6.5 U2 N N N N N N N N N N N
VMware vSphere Hypervisor (ESXi) 6.5 U3 N N N N N N N Y 1 N Y 1 N
VMware vSphere Hypervisor (ESXi) 6.7 N N N N N N N N N N N
VMware vSphere Hypervisor (ESXi) 6.7 U1 N N N N N N N N N N N
VMware vSphere Hypervisor (ESXi) 6.7 U2 N N N N N N N N N N N
VMware vSphere Hypervisor (ESXi) 6.7 U3 Y Y Y Y Y N N Y Y Y Y
VMware vSphere Hypervisor (ESXi) 7.0 N N N N N N N Y 1 Y 1 Y 1 Y 1
VMware vSphere Hypervisor (ESXi) 7.0 U1 N N N N N Y Y Y 1 Y Y 1 Y
VMware vSphere Hypervisor (ESXi) 7.0 U2 Y Y Y Y Y Y Y Y Y Y Y
VMware vSphere Hypervisor (ESXi) 7.0 U3 Y Y Y Y Y Y Y Y Y Y Y
VMware vSphere Hypervisor (ESXi) 8.0 Y Y Y Y Y Y Y Y Y Y Y
VMware vSphere Hypervisor (ESXi) 8.0 U1 Y Y Y Y Y Y Y Y Y Y Y
VMware vSphere Hypervisor (ESXi) 8.0 U2 Y Y Y Y Y Y Y Y Y Y Y
VMware vSphere Hypervisor (ESXi) 8.0 U3 N Y Y Y Y Y Y Y Y Y Y

1 The OS is not supported with EPYC 7003 processors.

2 ISG will not sell/preload this OS, but compatibility and cert only.

Table 8. Operating system support for ThinkSystem U.3 Kioxia CM6-V 1.6TB Mainstream NVMe PCIe 4.0 x4 Hot Swap SSD, 4XB7A17112 (Part 2 of 3)
Operating systems
SD530 (Xeon Gen 2)
SN550 (Xeon Gen 2)
SN850 (Xeon Gen 2)
SR570 (Xeon Gen 2)
SR590 (Xeon Gen 2)
SR630 (Xeon Gen 2)
SR650 (Xeon Gen 2)
SR850 (Xeon Gen 2)
SR850P (Xeon Gen 2)
SR860 (Xeon Gen 2)
SR950 (Xeon Gen 2)
Microsoft Windows 10 N N N N N N N N N N N
Microsoft Windows 11 N N N N N N N N N N N
Microsoft Windows Server 2012 R2 N N N N N N N N N N N
Microsoft Windows Server 2016 Y Y Y Y Y Y Y Y Y Y Y
Microsoft Windows Server 2019 Y Y Y Y Y Y Y Y Y Y Y
Microsoft Windows Server 2022 Y Y Y Y Y Y Y Y Y Y Y
Microsoft Windows Server 2025 N N N N N N N N N N N
Red Hat Enterprise Linux 6.10 N N N N N N N N N N N
Red Hat Enterprise Linux 6.9 N N N N N N N N N N N
Red Hat Enterprise Linux 7.3 N N N N N N N N N N N
Red Hat Enterprise Linux 7.4 N N N N N N N N N N N
Red Hat Enterprise Linux 7.5 N N N N N N N N N N N
Red Hat Enterprise Linux 7.6 Y Y Y Y Y Y Y Y Y Y Y
Red Hat Enterprise Linux 7.7 Y Y Y Y Y Y Y Y Y Y Y
Red Hat Enterprise Linux 7.8 Y Y Y Y Y Y Y Y Y Y Y
Red Hat Enterprise Linux 7.9 Y Y Y Y Y Y Y Y Y Y Y
Red Hat Enterprise Linux 8.0 Y Y Y Y Y Y Y Y Y Y Y
Red Hat Enterprise Linux 8.1 Y Y Y Y Y Y Y Y Y Y Y
Red Hat Enterprise Linux 8.10 N N N N N N N N N N Y
Red Hat Enterprise Linux 8.2 Y Y Y Y Y Y Y Y Y Y Y
Red Hat Enterprise Linux 8.3 Y Y Y Y Y Y Y Y Y Y Y
Red Hat Enterprise Linux 8.4 Y Y Y Y Y Y Y Y Y Y Y
Red Hat Enterprise Linux 8.5 Y Y Y Y Y Y Y Y Y Y Y
Red Hat Enterprise Linux 8.6 Y Y Y Y Y Y Y Y Y Y Y
Red Hat Enterprise Linux 8.7 Y Y Y Y Y Y Y Y Y Y Y
Red Hat Enterprise Linux 8.8 Y Y Y Y Y Y Y Y Y Y Y
Red Hat Enterprise Linux 8.9 Y Y Y Y Y Y Y Y Y Y Y
Red Hat Enterprise Linux 9.0 Y Y Y Y Y Y Y Y Y Y Y
Red Hat Enterprise Linux 9.1 Y Y Y Y Y Y Y Y Y Y Y
Red Hat Enterprise Linux 9.2 Y Y Y Y Y Y Y Y Y Y Y
Red Hat Enterprise Linux 9.3 Y Y Y Y Y Y Y Y Y Y Y
Red Hat Enterprise Linux 9.4 N N N N N N N N N N Y
Red Hat Enterprise Linux 9.5 N N N N N N N N N N Y
SUSE Linux Enterprise Server 11 SP4 N N N N N N N N N N N
SUSE Linux Enterprise Server 12 SP2 N N N N N N N N N N N
SUSE Linux Enterprise Server 12 SP2 with Xen N N N N N N N N N N N
SUSE Linux Enterprise Server 12 SP3 N N N N N N N N Y N N
SUSE Linux Enterprise Server 12 SP3 with Xen N N N N N N N N Y N N
SUSE Linux Enterprise Server 12 SP4 Y Y Y Y Y Y Y Y Y Y Y
SUSE Linux Enterprise Server 12 SP4 with Xen Y Y Y Y Y Y Y Y Y Y Y
SUSE Linux Enterprise Server 12 SP5 Y Y Y Y Y Y Y Y Y Y Y
SUSE Linux Enterprise Server 12 SP5 with Xen Y Y Y Y Y Y Y Y Y Y Y
SUSE Linux Enterprise Server 15 Y Y Y Y Y Y Y Y Y Y Y
SUSE Linux Enterprise Server 15 SP1 Y Y Y Y Y Y Y Y Y Y Y
SUSE Linux Enterprise Server 15 SP1 with Xen Y Y Y Y Y Y Y Y Y Y Y
SUSE Linux Enterprise Server 15 SP2 Y Y Y Y Y Y Y Y Y Y Y
SUSE Linux Enterprise Server 15 SP2 with Xen Y Y Y Y Y Y Y Y Y Y Y
SUSE Linux Enterprise Server 15 SP3 Y Y Y Y Y Y Y Y Y Y Y
SUSE Linux Enterprise Server 15 SP3 with Xen Y Y Y Y Y Y Y Y Y Y Y
SUSE Linux Enterprise Server 15 SP4 Y Y Y Y Y Y Y Y Y Y Y
SUSE Linux Enterprise Server 15 SP4 with Xen Y Y Y Y Y Y Y Y Y Y Y
SUSE Linux Enterprise Server 15 SP5 Y Y Y Y Y Y Y Y Y Y Y
SUSE Linux Enterprise Server 15 SP5 with Xen Y Y Y Y Y Y Y Y Y Y Y
SUSE Linux Enterprise Server 15 SP6 N N N N N N N N N N N
SUSE Linux Enterprise Server 15 with Xen Y Y Y Y Y Y Y Y Y Y Y
Ubuntu 18.04.5 LTS N N N N N N N N N N N
Ubuntu 20.04 LTS N N N N N N N N N N N
Ubuntu 22.04 LTS Y Y Y Y Y Y Y Y Y Y Y
Ubuntu 24.04 LTS N N N N N N N N N N N
VMware vSphere Hypervisor (ESXi) 6.5 N N N N N N N N N N N
VMware vSphere Hypervisor (ESXi) 6.5 U1 N N N N N N N N N N N
VMware vSphere Hypervisor (ESXi) 6.5 U2 Y Y Y Y Y Y Y Y Y Y Y
VMware vSphere Hypervisor (ESXi) 6.5 U3 Y Y Y Y Y Y Y Y Y Y Y
VMware vSphere Hypervisor (ESXi) 6.7 N N N N N N N N N N N
VMware vSphere Hypervisor (ESXi) 6.7 U1 Y Y Y Y Y Y Y Y Y Y Y
VMware vSphere Hypervisor (ESXi) 6.7 U2 Y Y Y Y Y Y Y Y Y Y Y
VMware vSphere Hypervisor (ESXi) 6.7 U3 Y Y Y Y Y Y Y Y Y Y Y
VMware vSphere Hypervisor (ESXi) 7.0 Y Y Y Y Y Y Y Y Y Y Y
VMware vSphere Hypervisor (ESXi) 7.0 U1 Y Y Y Y Y Y Y Y Y Y Y
VMware vSphere Hypervisor (ESXi) 7.0 U2 Y Y Y Y Y Y Y Y Y Y Y
VMware vSphere Hypervisor (ESXi) 7.0 U3 Y Y Y Y Y Y Y Y Y Y Y
VMware vSphere Hypervisor (ESXi) 8.0 Y Y Y Y Y Y Y Y Y Y Y
VMware vSphere Hypervisor (ESXi) 8.0 U1 Y Y Y Y Y Y Y Y Y Y Y
VMware vSphere Hypervisor (ESXi) 8.0 U2 Y Y Y Y Y Y Y Y Y Y Y
VMware vSphere Hypervisor (ESXi) 8.0 U3 Y Y Y Y Y Y Y Y Y Y Y
Table 9. Operating system support for ThinkSystem U.3 Kioxia CM6-V 1.6TB Mainstream NVMe PCIe 4.0 x4 Hot Swap SSD, 4XB7A17112 (Part 3 of 3)
Operating systems
SD530 (Xeon Gen 1)
SN550 (Xeon Gen 1)
SN850 (Xeon Gen 1)
SR570 (Xeon Gen 1)
SR590 (Xeon Gen 1)
SR630 (Xeon Gen 1)
SR650 (Xeon Gen 1)
SR850 (Xeon Gen 1)
SR860 (Xeon Gen 1)
SR950 (Xeon Gen 1)
Microsoft Windows 10 N N N N N N N N N N
Microsoft Windows 11 N N N N N N N N N N
Microsoft Windows Server 2012 R2 Y Y Y Y Y Y Y Y Y Y
Microsoft Windows Server 2016 Y Y Y Y Y Y Y Y Y Y
Microsoft Windows Server 2019 Y Y Y Y Y Y Y Y Y Y
Microsoft Windows Server 2022 Y Y Y Y Y Y Y Y Y Y
Microsoft Windows Server 2025 N N N N N N N N N N
Red Hat Enterprise Linux 6.10 Y Y Y Y Y Y Y Y Y Y
Red Hat Enterprise Linux 6.9 Y Y Y Y Y Y Y Y Y Y
Red Hat Enterprise Linux 7.3 Y Y Y N N Y Y Y N Y
Red Hat Enterprise Linux 7.4 Y Y Y Y Y Y Y Y Y Y
Red Hat Enterprise Linux 7.5 Y Y Y Y Y Y Y Y Y Y
Red Hat Enterprise Linux 7.6 Y Y Y Y Y Y Y Y Y Y
Red Hat Enterprise Linux 7.7 Y Y Y Y Y Y Y Y Y Y
Red Hat Enterprise Linux 7.8 Y Y Y Y Y Y Y Y Y Y
Red Hat Enterprise Linux 7.9 Y Y Y Y Y Y Y Y Y Y
Red Hat Enterprise Linux 8.0 Y Y Y Y Y Y Y Y Y Y
Red Hat Enterprise Linux 8.1 Y Y Y Y Y Y Y Y Y Y
Red Hat Enterprise Linux 8.10 N N N N N N N N N N
Red Hat Enterprise Linux 8.2 Y Y Y Y Y Y Y Y Y Y
Red Hat Enterprise Linux 8.3 Y Y Y Y Y Y Y Y Y Y
Red Hat Enterprise Linux 8.4 Y Y Y Y Y Y Y Y Y Y
Red Hat Enterprise Linux 8.5 Y Y Y Y Y Y Y Y Y Y
Red Hat Enterprise Linux 8.6 Y Y Y Y Y Y Y Y Y Y
Red Hat Enterprise Linux 8.7 Y Y Y Y Y Y Y Y Y Y
Red Hat Enterprise Linux 8.8 Y Y Y Y Y Y Y Y Y Y
Red Hat Enterprise Linux 8.9 N N N N N N N N N N
Red Hat Enterprise Linux 9.0 Y Y Y Y Y Y Y Y Y Y
Red Hat Enterprise Linux 9.1 Y Y Y Y Y Y Y Y Y Y
Red Hat Enterprise Linux 9.2 Y Y Y Y Y Y Y Y Y Y
Red Hat Enterprise Linux 9.3 N N N N N N N N N N
Red Hat Enterprise Linux 9.4 N N N N N N N N N N
Red Hat Enterprise Linux 9.5 N N N N N N N N N N
SUSE Linux Enterprise Server 11 SP4 Y Y Y Y Y Y Y Y Y Y
SUSE Linux Enterprise Server 12 SP2 Y N Y N N Y Y Y N Y
SUSE Linux Enterprise Server 12 SP2 with Xen Y N Y N N Y Y Y N Y
SUSE Linux Enterprise Server 12 SP3 Y Y Y Y Y Y Y Y Y Y
SUSE Linux Enterprise Server 12 SP3 with Xen Y Y Y Y Y Y Y Y Y Y
SUSE Linux Enterprise Server 12 SP4 Y Y Y Y Y Y Y Y Y Y
SUSE Linux Enterprise Server 12 SP4 with Xen Y Y Y Y Y Y Y Y Y Y
SUSE Linux Enterprise Server 12 SP5 Y Y Y Y Y Y Y Y Y Y
SUSE Linux Enterprise Server 12 SP5 with Xen Y Y Y Y Y Y Y Y Y Y
SUSE Linux Enterprise Server 15 Y Y Y Y Y Y Y Y Y Y
SUSE Linux Enterprise Server 15 SP1 Y Y Y Y Y Y Y Y Y Y
SUSE Linux Enterprise Server 15 SP1 with Xen Y Y Y Y Y Y Y Y Y Y
SUSE Linux Enterprise Server 15 SP2 Y Y Y Y Y Y Y Y Y Y
SUSE Linux Enterprise Server 15 SP2 with Xen Y Y Y Y Y Y Y Y Y Y
SUSE Linux Enterprise Server 15 SP3 Y Y Y Y Y Y Y Y Y Y
SUSE Linux Enterprise Server 15 SP3 with Xen Y Y Y Y Y Y Y Y Y Y
SUSE Linux Enterprise Server 15 SP4 Y Y Y Y Y Y Y Y Y Y
SUSE Linux Enterprise Server 15 SP4 with Xen Y Y Y Y Y Y Y Y Y Y
SUSE Linux Enterprise Server 15 SP5 Y Y Y Y Y Y Y Y Y Y
SUSE Linux Enterprise Server 15 SP5 with Xen Y Y Y Y Y Y Y Y Y Y
SUSE Linux Enterprise Server 15 SP6 N N N N N N N N N N
SUSE Linux Enterprise Server 15 with Xen Y Y Y Y Y Y Y Y Y Y
Ubuntu 18.04.5 LTS N N N N N N N N N N
Ubuntu 20.04 LTS N N N N N N N N N N
Ubuntu 22.04 LTS Y Y Y Y Y Y Y Y Y Y
Ubuntu 24.04 LTS N N N N N N N N N N
VMware vSphere Hypervisor (ESXi) 6.5 Y Y Y N N Y Y Y N Y
VMware vSphere Hypervisor (ESXi) 6.5 U1 Y Y Y Y Y Y Y Y Y Y
VMware vSphere Hypervisor (ESXi) 6.5 U2 Y Y Y Y Y Y Y Y Y Y
VMware vSphere Hypervisor (ESXi) 6.5 U3 Y Y Y Y Y Y Y Y Y Y
VMware vSphere Hypervisor (ESXi) 6.7 Y Y Y Y Y Y Y Y Y Y
VMware vSphere Hypervisor (ESXi) 6.7 U1 Y Y Y Y Y Y Y Y Y Y
VMware vSphere Hypervisor (ESXi) 6.7 U2 Y Y Y Y Y Y Y Y Y Y
VMware vSphere Hypervisor (ESXi) 6.7 U3 Y Y Y Y Y Y Y Y Y Y
VMware vSphere Hypervisor (ESXi) 7.0 Y Y Y Y Y Y Y Y Y Y
VMware vSphere Hypervisor (ESXi) 7.0 U1 Y Y Y Y Y Y Y Y Y Y
VMware vSphere Hypervisor (ESXi) 7.0 U2 Y Y Y Y Y Y Y Y Y Y
VMware vSphere Hypervisor (ESXi) 7.0 U3 Y Y Y Y Y Y Y Y Y Y
VMware vSphere Hypervisor (ESXi) 8.0 Y Y Y Y Y Y Y Y Y Y
VMware vSphere Hypervisor (ESXi) 8.0 U1 Y Y Y Y Y Y Y Y Y Y
VMware vSphere Hypervisor (ESXi) 8.0 U2 Y Y Y Y Y Y Y Y Y Y
VMware vSphere Hypervisor (ESXi) 8.0 U3 Y Y Y Y Y Y Y Y Y Y

Warranty

The ThinkSystem Kioxia CM6-V Mainstream NVMe SSDs carry a one-year, customer-replaceable unit (CRU) limited warranty. When the SSDs are installed in a supported server, these drives assume the system’s base warranty and any warranty upgrades.

Solid State Memory cells have an intrinsic, finite number of program/erase cycles that each cell can incur. As a result, each solid state device has a maximum amount of program/erase cycles to which it can be subjected. The warranty for Lenovo solid state drives (SSDs) is limited to drives that have not reached the maximum guaranteed number of program/erase cycles, as documented in the Official Published Specifications for the SSD product. A drive that reaches this limit may fail to operate according to its Specifications.

Physical specifications

The ThinkSystem Kioxia CM6-V Mainstream NVMe SSDs have the following physical specifications:

Dimensions and weight (approximate, without the drive tray):

  • Height: 15 mm (0.6 in.)
  • Width: 70 mm (2.8 in.)
  • Depth: 100 mm (4.0 in.)
  • Weight: 130 g (5.3 oz)

Operating environment

The ThinkSystem Kioxia CM6-V Mainstream NVMe SSDs are supported in the following environment:

  • Temperature:
    • Operating: 0 to 70 °C (32 to 158 °F)
    • Transport: -40 to 80 °C (-40 to 176 °F)
  • Relative humidity: 5 to 95% (non-condensing)
  • Maximum altitude:
    • Operating: 5,486 m (18,000 ft)
    • Non-operating: 12,192 m (40,000 ft)
  • Shock: 1,000 G (Max) at 0.5 ms
  • Vibration: 2.17 GRMS (5-800 Hz)

Agency approvals

The ThinkSystem Kioxia CM6-V Mainstream NVMe SSDs conform to the following regulations:

  • Underwriters Laboratories: UL60950-1
  • Canada: CAN/CSA-C22.2 No.60950-1
  • TUV: EN 60950-1
  • BSMI (Taiwan): CNS 13438 (CISPR Pub. 22 Class B): D33003
  • MSIP: KN22, KN24 (CISPR Pub. 22 Class B)
  • Australia/New Zealand: AS/NZS CISPR32:2015 Class B
  • Canada: ICES-003 Issue 6 Class B
  • EMC: EN55022 (2015) Class B
  • EMC: EN55035 (2017)
  • RoHS 2011/65/EU: EN50581 (2012) Category 3

Related product families

Product families related to this document are the following:

Trademarks

Lenovo and the Lenovo logo are trademarks or registered trademarks of Lenovo in the United States, other countries, or both. A current list of Lenovo trademarks is available on the Web at https://www.lenovo.com/us/en/legal/copytrade/.

The following terms are trademarks of Lenovo in the United States, other countries, or both:
Lenovo®
ServerProven®
ThinkSystem®

The following terms are trademarks of other companies:

AMD is a trademark of Advanced Micro Devices, Inc.

Intel® and Xeon® are trademarks of Intel Corporation or its subsidiaries.

Linux® is the trademark of Linus Torvalds in the U.S. and other countries.

Microsoft®, Windows Server®, and Windows® are trademarks of Microsoft Corporation in the United States, other countries, or both.

Other company, product, or service names may be trademarks or service marks of others.