Author
Updated
23 May 2023Form Number
LP1439PDF size
14 pages, 682 KBAbstract
The Lenovo ThinkSystem 4350-8i and 4350-16i SAS/SATA 12Gb HBAs are high performance host bus adapters for internal storage connectivity in ThinkSystem servers. They integrate the latest SAS technology and offer eight or 16 lanes of 12 Gbps SAS.
This product guide provides essential presales information to understand the ThinkSystem internal HBAs and their key features, specifications, and compatibility. This guide is intended for technical specialists, sales specialists, sales engineers, IT architects, and other IT professionals who want to learn more about the HBAs and consider their use in IT solutions.
Change History
Changes in the May 23, 2023 update:
- The adapters now support SED drives - Technical specifications section
Introduction
The Lenovo ThinkSystem 4350-8i and 4350-16i SAS/SATA 12Gb HBAs are high performance host bus adapters manufactured by Lenovo for internal storage connectivity in ThinkSystem servers. They integrate the latest SAS technology and offer eight or 16 lanes of 12 Gbps SAS. With a low-profile form-factor design, these adapters offers two or four x4 internal mini-SAS HD connectors.
The following figure shows the ThinkSystem 4350-16i SAS/SATA 12Gb HBA.
Did you know?
The ThinkSystem 4350 HBAs provide high levels of storage performance and scalability. The 16-port adapter can achieve up to 1.7M IOPS (random read using 4KB blocks) and the 8-port adapter can achieve up to 1.5M IOPS.
Rigorous testing of the ThinkSystem HBAs by Lenovo through the ServerProven program ensures a high degree of confidence in storage subsystem compatibility and reliability. Providing an additional peace of mind, the controller is covered under Lenovo warranty.
Part number information
The following table provides the ordering part numbers for the adapters.
Part number | Feature code | Description |
---|---|---|
4Y37A72480 | BJHH | ThinkSystem 4350-8i SAS/SATA 12Gb HBA |
4Y37A72481 | BJHJ | ThinkSystem 4350-16i SAS/SATA 12Gb HBA |
The part numbers include:
- Host Bus Adapter with 3U full-height bracket attached
- 2U low-profile bracket
Technical specifications
The 4350 HBAs have the following features and specifications:
- PCIe 3.0 x8 host interface
- 12 Gbps SAS/SATA host bus adapter, based on the Adaptec HBA 1100-8i and 1100-16i
- PCI low profile, half-length form factor
- 8 or 16 internal 12 Gbps SAS/SATA ports
- 4350-8i support connectivity to 8 internal drives
- 4350-16i support connectivity to 16 internal drives
- Up to 12 Gbps throughput per port
- Supports 12, 6, or 3 Gbps SAS speeds
- Supports 6 or 3 Gbps SATA speeds
- Two internal x4 HD Mini-SAS connectors (SFF-8643)
- Non-RAID (JBOD mode, known as “raw” or "HBA mode” in Adaptec parlance) support for SAS and SATA HDDs and SSDs (RAID not supported)
- Optimized for SSD performance
- High performance architecture with a queue depth of up to 1014
- Advanced power management support
- Supports 512e, 512n and 4K sector formatted drives
- TLR
- SATA Native Command Queuing (NCQ)
- S.M.A.R.T. support.
The specifications of the adapters are listed in the following table.
Feature | 4350-8i | 4350-16i |
---|---|---|
Form factor | PCIe low profile | PCIe low profile |
Controller chip | Adaptec PM8222 SmartIOC 2100 | Adaptec PM8238 SmartIOC 2100 |
Adaptec equivalent | Adaptec HBA 1100-8i | Adaptec HBA 1100-16i |
Host interface | PCIe 3.0 x8 | PCIe 3.0 x8 |
Port interface | 12 Gb SAS | 12 Gb SAS |
Number of ports | 8 | 16 |
Port connectors | 2x Mini-SAS HD x4 (SFF-8643) | 4x Mini-SAS HD x4 (SFF-8643) |
Drive interface | SAS, SATA | SAS, SATA |
Drive type | HDD, SSD | HDD, SSD |
Maximum devices | 8 | 16 |
RAID levels | No RAID | No RAID |
JBOD mode (HBA mode / Raw) | Yes | Yes |
Cache | No | No |
SED support (pass-through) | Yes | Yes |
To compare these adapters to others in the ThinkSystem portfolio, see the ThinkSystem RAID Adapter and HBA Reference:
https://lenovopress.com/lp1288-thinksystem-raid-adapter-and-hba-reference
Features
Resiliency and Efficiency
The 4350 SAS/SATA HBA Series delivers enterprise resiliency with its broadly deployed Smart Storage stack. Based on the Adaptec PM8222 8x12G SmartIOC 2100 SAS/SATA protocol controller, the 4350 HBAs provide a robust and stable solution that can handle the toughest system workloads and configurations. The adapters offers over 40% power savings compared to previous generations, and significant power advantages versus competing solutions.
Optimized for New Devices and New Use Cases
The 4350 HBAs support the latest SAS and SATA SSDs. They are also optimized for software-defined storage solutions such as Microsoft Azure Stack HCI and VMware vSAN.
Maximum Performance
The 4350 HBAs provides the highest levels of storage performance and scalability for next-generation data centers. Using the SmartPQI host OS device drivers that are optimized for low-latency solid-state drives, the adapters can aggregate the performance of devices to the limits of the PCIe Gen3 host bus at 6.6 Gbps, and achieve up to 1.7M IOPS and 60% higher IOPS performance with SATA devices without additional overhead or latency.
Ease of Use
The 4350 HBAs, with their broad operating system support and ecosystem compatibility, are easy to implement and scale. The unified maxView management tools and drivers across the 4350 HBA, RAID 5350, and RAID 9350 adapters enable easy manageability across the Adaptec-based storage adapter family.
Support for Lenovo system management tools is listed in the following table.
Function | Lenovo XClarity Controller | Lenovo XClarity Provisioning Manager | Lenovo XClarity Essentials OneCLI (out-of-band) | Lenovo XClarity Essentials OneCLI (in-band) | Lenovo XClarity Administrator | Bare Metal Update / Bootable Media Creator |
---|---|---|---|---|---|---|
Adapter FRU Inventory Details | Supported | Supported | Supported | Supported | Supported | No support |
Disk Inventory Details | Supported | Supported | Supported | Supported | Supported | No support |
Firmware Update | Supported | No support | Supported | Supported | Supported | Supported |
Monitoring/ Events/ Log Capture | Supported* | Supported | Supported* | Supported | Supported* | No support |
* No capture of controller firmware log
Server support
The following tables list the ThinkSystem servers that are compatible.
Part Number | Description | Edge | 1S Intel V2 | AMD V3 | Intel V3 | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
SE350 (7Z46 / 7D1X) |
SE350 V2 (7DA9) |
SE360 V2 (7DAM) |
SE450 (7D8T) |
SE455 V3 (7DBY) |
ST50 V2 (7D8K / 7D8J) |
ST250 V2 (7D8G / 7D8F) |
SR250 V2 (7D7R / 7D7Q) |
SR635 V3 (7D9H / 7D9G) |
SR655 V3 (7D9F / 7D9E) |
SR645 V3 (7D9D / 7D9C) |
SR665 V3 (7D9B / 7D9A) |
SR675 V3 (7D9Q / 7D9R) |
ST650 V3 (7D7B / 7D7A) |
SR630 V3 (7D72 / 7D73) |
SR650 V3 (7D75 / 7D76) |
SR850 V3 (7D97 / 7D96) |
SR860 V3 (7D94 / 7D93) |
SR950 V3 (7DC5 / 7DC4) |
||
4Y37A72480 | ThinkSystem 4350-8i SAS/SATA 12Gb HBA | N | N | N | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | N |
4Y37A72481 | ThinkSystem 4350-16i SAS/SATA 12Gb HBA | N | N | N | N | N | N | N | N | Y | Y | Y | Y | N | Y | Y | Y | Y | Y | N |
Part Number | Description | Dense V3 | 2S Intel V2 | AMD V1 | Dense V2 | 4S V2 | 8S | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
SD665 V3 (7D9P) |
SD665-N V3 (7DAZ) |
SD650 V3 (7D7M) |
SD650-I V3 (7D7L) |
ST650 V2 (7Z75 / 7Z74) |
SR630 V2 (7Z70 / 7Z71) |
SR650 V2 (7Z72 / 7Z73) |
SR670 V2 (7Z22 / 7Z23) |
SR635 (7Y98 / 7Y99) |
SR655 (7Y00 / 7Z01) |
SR655 Client OS |
SR645 (7D2Y / 7D2X) |
SR665 (7D2W / 7D2V) |
SD630 V2 (7D1K) |
SD650 V2 (7D1M) |
SD650-N V2 (7D1N) |
SN550 V2 (7Z69) |
SR850 V2 (7D31 / 7D32) |
SR860 V2 (7Z59 / 7Z60) |
SR950 (7X11 / 7X12) |
||
4Y37A72480 | ThinkSystem 4350-8i SAS/SATA 12Gb HBA | N | N | N | N | Y | Y | Y | Y | N | N | N | Y1 | Y1 | N | N | N | N | Y | Y | N |
4Y37A72481 | ThinkSystem 4350-16i SAS/SATA 12Gb HBA | N | N | N | N | Y | Y | Y | N | N | N | N | Y1 | Y1 | N | N | N | N | Y | Y | N |
- Supported in the SR645 and SR665 only with an EPYC 7003 "Milan" processor. Not supported with an EPYC 7002 "Rome" processor.
Part Number | Description | 4S V1 | 1S Intel V1 | 2S Intel V1 | Dense V1 | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
SR850 (7X18 / 7X19) |
SR850P (7D2F / 2D2G) |
SR860 (7X69 / 7X70) |
ST50 (7Y48 / 7Y50) |
ST250 (7Y45 / 7Y46) |
SR150 (7Y54) |
SR250 (7Y52 / 7Y51) |
ST550 (7X09 / 7X10) |
SR530 (7X07 / 7X08) |
SR550 (7X03 / 7X04) |
SR570 (7Y02 / 7Y03) |
SR590 (7X98 / 7X99) |
SR630 (7X01 / 7X02) |
SR650 (7X05 / 7X06) |
SR670 (7Y36 / 7Y37) |
SD530 (7X21) |
SD650 (7X58) |
SN550 (7X16) |
SN850 (7X15) |
||
4Y37A72480 | ThinkSystem 4350-8i SAS/SATA 12Gb HBA | N | N | N | N | N | N | N | Y | N | N | N | Y | Y | Y | N | N | N | N | N |
4Y37A72481 | ThinkSystem 4350-16i SAS/SATA 12Gb HBA | N | N | N | N | N | N | N | N | N | N | N | N | Y | Y | N | N | N | N | N |
Note: The use of both an Intel E810 network adapter and an X350 HBA/RAID adapter (9350, 5350 and 4350) is currently not supported in ThinkSystem servers. For details see Support Tip HT513226. Planned support for this combination of adapters is 4Q/2023 (SI 23-2).
Operating system support
The following tables list the supported operating systems for the adapters:
Operating systems | SE450 |
SE455 V3 |
SR630 V3 |
SR635 V3 |
SR645 V3 |
SR650 V3 |
SR655 V3 |
SR665 V3 |
SR675 V3 |
SR850 V3 |
SR860 V3 |
ST650 V3 |
SR250 V2 |
ST250 V2 |
ST50 V2 |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Microsoft Windows 10 | N | N | N | Y | Y | Y 1 | Y | Y | N | N | N | N | N | N | N |
Microsoft Windows 11 | N | N | N | Y | Y | Y 1 | Y | Y | N | N | N | N | N | N | N |
Microsoft Windows Server 2016 | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
Microsoft Windows Server 2019 | Y | Y | Y 1 | Y | Y | Y 1 | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Microsoft Windows Server 2022 | Y | Y | Y 1 | Y | Y | Y 1 | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Red Hat Enterprise Linux 7.7 | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
Red Hat Enterprise Linux 7.8 | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
Red Hat Enterprise Linux 7.9 | Y | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
Red Hat Enterprise Linux 8.0 | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
Red Hat Enterprise Linux 8.1 | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
Red Hat Enterprise Linux 8.2 | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
Red Hat Enterprise Linux 8.3 | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
Red Hat Enterprise Linux 8.4 | Y | N | N | N | N | N | N | N | N | N | N | N | Y | Y | Y |
Red Hat Enterprise Linux 8.5 | Y | N | N | N | N | N | N | N | N | N | N | N | Y | Y | Y |
Red Hat Enterprise Linux 8.6 | Y | Y | Y 1 | Y | Y | Y 1 | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Red Hat Enterprise Linux 8.7 | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Red Hat Enterprise Linux 8.8 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Red Hat Enterprise Linux 8.9 | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Red Hat Enterprise Linux 9.0 | Y | Y | Y 1 | Y | Y | Y 1 | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Red Hat Enterprise Linux 9.1 | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Red Hat Enterprise Linux 9.2 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Red Hat Enterprise Linux 9.3 | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
SUSE Linux Enterprise Server 12 SP3 | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
SUSE Linux Enterprise Server 12 SP4 | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
SUSE Linux Enterprise Server 12 SP5 | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
SUSE Linux Enterprise Server 15 SP1 | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
SUSE Linux Enterprise Server 15 SP2 | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
SUSE Linux Enterprise Server 15 SP3 | N | N | N | N | N | N | N | N | N | N | N | N | Y | Y | Y |
SUSE Linux Enterprise Server 15 SP4 | Y | Y | Y 1 | Y | Y | Y 1 | Y | Y | Y | Y | Y | Y | Y | Y | Y |
SUSE Linux Enterprise Server 15 SP5 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Ubuntu 18.04.5 LTS | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
Ubuntu 18.04.6 LTS | Y | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
Ubuntu 20.04 LTS | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
Ubuntu 20.04.5 LTS | Y | Y | N | Y | Y | N | Y | Y | Y | N | N | N | N | N | N |
Ubuntu 22.04 LTS | Y | N | Y 1 | Y | Y | Y 1 | Y | Y | Y | N | N | Y | Y | Y | Y |
Ubuntu 22.04.2 LTS | N | Y | N | N | N | N | N | N | N | N | N | N | N | N | N |
VMware vSphere Hypervisor (ESXi) 6.7 U2 | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
VMware vSphere Hypervisor (ESXi) 6.7 U3 | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
VMware vSphere Hypervisor (ESXi) 7.0 | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
VMware vSphere Hypervisor (ESXi) 7.0 U1 | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
VMware vSphere Hypervisor (ESXi) 7.0 U2 | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
VMware vSphere Hypervisor (ESXi) 7.0 U3 | Y | Y | Y 1 | Y | Y | Y 1 | Y | Y | Y | Y | Y | Y | Y | Y | Y |
VMware vSphere Hypervisor (ESXi) 8.0 | Y | N | Y 1 | Y | Y | Y 1 | Y | Y | N | N | N | N | Y | Y | Y |
VMware vSphere Hypervisor (ESXi) 8.0 U1 | Y | Y | Y 2 | Y | Y | Y 2 | Y | Y | Y | Y | Y | Y | Y | Y | Y |
VMware vSphere Hypervisor (ESXi) 8.0 U2 | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
1 For limitation, please refer Support Tip 103500, Support Tip 104332
2 For limitation, please refer Support Tip 104278
Operating systems | SR630 V2 |
SR650 V2 |
SR670 V2 |
SR850 V2 |
SR860 V2 |
ST650 V2 |
SR645 |
SR665 |
SR590 (Xeon Gen 2) |
SR630 (Xeon Gen 2) |
SR650 (Xeon Gen 2) |
ST550 (Xeon Gen 2) |
SR590 (Xeon Gen 1) |
SR630 (Xeon Gen 1) |
SR650 (Xeon Gen 1) |
ST550 (Xeon Gen 1) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Microsoft Windows 10 | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
Microsoft Windows 11 | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
Microsoft Windows Server 2016 | Y | Y | Y | Y | Y | Y | Y 1 | Y 1 | Y | Y | Y | Y | Y | Y | Y | Y |
Microsoft Windows Server 2019 | Y | Y | Y | Y | Y | Y | Y 1 | Y 1 | Y | Y | Y | Y | Y | Y | Y | Y |
Microsoft Windows Server 2022 | Y | Y | Y | Y | Y | Y | Y 1 | Y 1 | Y | Y | Y | Y | Y | Y | Y | Y |
Red Hat Enterprise Linux 7.7 | N | N | N | N | N | N | N | N | Y | Y | Y | Y | Y | Y | Y | Y |
Red Hat Enterprise Linux 7.8 | N | N | N | N | N | N | N | N | Y | Y | Y | Y | Y | Y | Y | Y |
Red Hat Enterprise Linux 7.9 | Y | Y | Y | Y | Y | Y | N | N | Y | Y | Y | Y | Y | Y | Y | Y |
Red Hat Enterprise Linux 8.0 | N | N | N | N | N | N | N | N | Y | Y | Y | Y | Y | Y | Y | Y |
Red Hat Enterprise Linux 8.1 | N | N | N | N | N | N | N | N | Y | Y | Y | Y | Y | Y | Y | Y |
Red Hat Enterprise Linux 8.2 | Y | Y | Y | Y | Y | Y | N | N | Y | Y | Y | Y | Y | Y | Y | Y |
Red Hat Enterprise Linux 8.3 | Y | Y | Y | Y | Y | Y | Y 1 | Y 1 | Y | Y | Y | Y | Y | Y | Y | Y |
Red Hat Enterprise Linux 8.4 | Y | Y | Y | Y | Y | Y | Y 1 | Y 1 | Y | Y | Y | Y | Y | Y | Y | Y |
Red Hat Enterprise Linux 8.5 | Y | Y | Y | Y | Y | Y | Y 1 | Y 1 | Y | Y | Y | Y | Y | Y | Y | Y |
Red Hat Enterprise Linux 8.6 | Y | Y | Y | Y | Y | Y | Y 1 | Y 1 | Y | Y | Y | Y | Y | Y | Y | Y |
Red Hat Enterprise Linux 8.7 | Y | Y | Y | Y | Y | Y | Y 1 | Y 1 | Y | Y | Y | Y | Y | Y | Y | Y |
Red Hat Enterprise Linux 8.8 | Y | Y | Y | Y | Y | Y | Y 1 | Y 1 | Y | Y | Y | Y | Y | Y | Y | Y |
Red Hat Enterprise Linux 8.9 | Y | Y | Y | Y | Y | Y | Y 1 | Y 1 | Y | Y | Y | Y | N | N | N | N |
Red Hat Enterprise Linux 9.0 | Y | Y | Y | Y | Y | Y | Y 1 | Y 1 | Y | Y | Y | Y | Y | Y | Y | Y |
Red Hat Enterprise Linux 9.1 | Y | Y | Y | Y | Y | Y | Y 1 | Y 1 | Y | Y | Y | Y | Y | Y | Y | Y |
Red Hat Enterprise Linux 9.2 | Y | Y | Y | Y | Y | Y | Y 1 | Y 1 | Y | Y | Y | Y | Y | Y | Y | Y |
Red Hat Enterprise Linux 9.3 | Y | Y | Y | Y | Y | Y | Y 1 | Y 1 | Y | Y | Y | Y | N | N | N | N |
SUSE Linux Enterprise Server 12 SP3 | N | N | N | N | N | N | N | N | N | N | N | N | Y | Y | Y | Y |
SUSE Linux Enterprise Server 12 SP4 | N | N | N | N | N | N | N | N | Y | Y | Y | Y | Y | Y | Y | Y |
SUSE Linux Enterprise Server 12 SP5 | Y | Y | Y | Y | Y | Y | Y 1 | Y 1 | Y | Y | Y | Y | Y | Y | Y | Y |
SUSE Linux Enterprise Server 15 SP1 | N | N | N | N | N | N | N | N | Y | Y | Y | Y | Y | Y | Y | Y |
SUSE Linux Enterprise Server 15 SP2 | Y | Y | Y | Y | Y | Y | Y 1 | Y 1 | Y | Y | Y | Y | Y | Y | Y | Y |
SUSE Linux Enterprise Server 15 SP3 | Y | Y | Y | Y | Y | Y | Y 1 | Y 1 | Y | Y | Y | Y | Y | Y | Y | Y |
SUSE Linux Enterprise Server 15 SP4 | Y | Y | Y | Y | Y | Y | Y 1 | Y 1 | Y | Y | Y | Y | Y | Y | Y | Y |
SUSE Linux Enterprise Server 15 SP5 | Y | Y | Y | Y | Y | Y | Y 1 | Y 1 | Y | Y | Y | Y | Y | Y | Y | Y |
Ubuntu 18.04.5 LTS | Y | Y | Y | N | N | Y | N | N | N | N | N | N | N | N | N | N |
Ubuntu 18.04.6 LTS | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
Ubuntu 20.04 LTS | Y | Y | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
Ubuntu 20.04.5 LTS | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
Ubuntu 22.04 LTS | Y | Y | Y | Y | Y | Y | Y 1 | Y 1 | Y | Y | Y | Y | Y | Y | Y | Y |
Ubuntu 22.04.2 LTS | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
VMware vSphere Hypervisor (ESXi) 6.7 U2 | N | N | N | N | N | N | N | N | Y | Y | Y | Y | Y | Y | Y | Y |
VMware vSphere Hypervisor (ESXi) 6.7 U3 | Y | Y | Y | N | N | Y | Y 1 | Y 1 | Y | Y | Y | Y | Y | Y | Y | Y |
VMware vSphere Hypervisor (ESXi) 7.0 | N | N | N | N | N | N | N | N | Y | Y | Y | Y | Y | Y | Y | Y |
VMware vSphere Hypervisor (ESXi) 7.0 U1 | N | N | N | Y | Y | N | Y 1 | Y 1 | Y | Y | Y | Y | Y | Y | Y | Y |
VMware vSphere Hypervisor (ESXi) 7.0 U2 | Y | Y | Y | Y | Y | Y | Y 1 | Y 1 | Y | Y | Y | Y | Y | Y | Y | Y |
VMware vSphere Hypervisor (ESXi) 7.0 U3 | Y | Y | Y | Y | Y | Y | Y 1 | Y 1 | Y | Y | Y | Y | Y | Y | Y | Y |
VMware vSphere Hypervisor (ESXi) 8.0 | Y | Y | Y | Y | Y | Y | Y 1 | Y 1 | Y | Y | Y | Y | Y | Y | Y | Y |
VMware vSphere Hypervisor (ESXi) 8.0 U1 | Y | Y | Y | Y | Y | Y | Y 1 | Y 1 | Y | Y | Y | Y | Y | Y | Y | Y |
VMware vSphere Hypervisor (ESXi) 8.0 U2 | Y | Y | Y | Y | Y | Y | Y 1 | Y 1 | Y | Y | Y | Y | Y | Y | Y | Y |
1 HW is not supported with EPYC 7002 processors.
Operating systems | SR630 V3 |
SR635 V3 |
SR645 V3 |
SR650 V3 |
SR655 V3 |
SR665 V3 |
SR850 V3 |
SR860 V3 |
ST650 V3 |
SR630 V2 |
SR650 V2 |
SR850 V2 |
SR860 V2 |
ST650 V2 |
SR645 |
SR665 |
SR630 (Xeon Gen 2) |
SR650 (Xeon Gen 2) |
SR630 (Xeon Gen 1) |
SR650 (Xeon Gen 1) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Microsoft Windows 10 | N | Y | Y | Y 1 | Y | Y | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
Microsoft Windows 11 | N | Y | Y | Y 1 | Y | Y | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
Microsoft Windows Server 2016 | N | N | N | N | N | N | N | N | N | Y | Y | Y | Y | Y | Y 6 | Y 6 | Y | Y | Y | Y |
Microsoft Windows Server 2019 | Y 1 | Y | Y | Y 3 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y 6 | Y 6 | Y | Y | Y | Y |
Microsoft Windows Server 2022 | Y 1 | Y | Y | Y 4 | Y 5 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y 6 | Y 6 | Y | Y | Y | Y |
Red Hat Enterprise Linux 7.7 | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | Y | Y | Y | Y |
Red Hat Enterprise Linux 7.8 | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | Y | Y | Y | Y |
Red Hat Enterprise Linux 7.9 | N | N | N | N | N | N | N | N | N | Y | Y | Y | Y | Y | N | N | Y | Y | Y | Y |
Red Hat Enterprise Linux 8.0 | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | Y | Y | Y | Y |
Red Hat Enterprise Linux 8.1 | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | Y | Y | Y | Y |
Red Hat Enterprise Linux 8.2 | N | N | N | N | N | N | N | N | N | Y | Y | Y | Y | Y | N | N | Y | Y | Y | Y |
Red Hat Enterprise Linux 8.3 | N | N | N | N | N | N | N | N | N | Y | Y | Y | Y | Y | Y 6 | Y 6 | Y | Y | Y | Y |
Red Hat Enterprise Linux 8.4 | N | N | N | N | N | N | N | N | N | Y | Y | Y | Y | Y | Y 6 | Y 6 | Y | Y | Y | Y |
Red Hat Enterprise Linux 8.5 | N | N | N | N | N | N | N | N | N | Y | Y | Y | Y | Y | Y 6 | Y 6 | Y | Y | Y | Y |
Red Hat Enterprise Linux 8.6 | Y 1 | Y | Y | Y 1 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y 6 | Y 6 | Y | Y | Y | Y |
Red Hat Enterprise Linux 8.7 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y 6 | Y 6 | Y | Y | Y | Y |
Red Hat Enterprise Linux 8.8 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y 6 | Y 6 | Y | Y | Y | Y |
Red Hat Enterprise Linux 8.9 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y 6 | Y 6 | Y | Y | N | N |
Red Hat Enterprise Linux 9.0 | Y 1 | Y | Y | Y 1 | Y 5 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y 6 | Y 6 | Y | Y | Y | Y |
Red Hat Enterprise Linux 9.1 | Y | Y | Y | Y | Y 5 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y 6 | Y 6 | Y | Y | Y | Y |
Red Hat Enterprise Linux 9.2 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y 6 | Y 6 | Y | Y | Y | Y |
Red Hat Enterprise Linux 9.3 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y 6 | Y 6 | Y | Y | N | N |
SUSE Linux Enterprise Server 12 SP3 | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | Y | Y |
SUSE Linux Enterprise Server 12 SP4 | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | Y | Y | Y | Y |
SUSE Linux Enterprise Server 12 SP5 | N | N | N | N | N | N | N | N | N | Y | Y | Y | Y | Y | Y 6 | Y 6 | Y | Y | Y | Y |
SUSE Linux Enterprise Server 15 SP1 | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | Y | Y | Y | Y |
SUSE Linux Enterprise Server 15 SP2 | N | N | N | N | N | N | N | N | N | Y | Y | Y | Y | Y | Y 6 | Y 6 | Y | Y | Y | Y |
SUSE Linux Enterprise Server 15 SP3 | N | N | N | N | N | N | N | N | N | Y | Y | Y | Y | Y | Y 6 | Y 6 | Y | Y | Y | Y |
SUSE Linux Enterprise Server 15 SP4 | Y 1 | Y | Y | Y 1 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y 6 | Y 6 | Y | Y | Y | Y |
SUSE Linux Enterprise Server 15 SP5 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y 6 | Y 6 | Y | Y | Y | Y |
Ubuntu 18.04.5 LTS | N | N | N | N | N | N | N | N | N | Y | Y | N | N | Y | N | N | N | N | N | N |
Ubuntu 20.04 LTS | N | N | N | N | N | N | N | N | N | Y | Y | N | N | N | N | N | N | N | N | N |
Ubuntu 20.04.5 LTS | N | Y | Y | N | Y | Y | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
Ubuntu 22.04 LTS | Y 1 | Y | Y | Y 1 | Y 5 | Y | N | N | Y | Y | Y | Y | Y | Y | Y 6 | Y 6 | Y | Y | Y | Y |
VMware vSphere Hypervisor (ESXi) 6.7 U2 | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | Y | Y | Y | Y |
VMware vSphere Hypervisor (ESXi) 6.7 U3 | N | N | N | N | N | N | N | N | N | Y | Y | N | N | Y | Y 6 | Y 6 | Y | Y | Y | Y |
VMware vSphere Hypervisor (ESXi) 7.0 | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | Y | Y | Y | Y |
VMware vSphere Hypervisor (ESXi) 7.0 U1 | N | N | N | N | N | N | N | N | N | N | N | Y | Y | N | Y 6 | Y 6 | Y | Y | Y | Y |
VMware vSphere Hypervisor (ESXi) 7.0 U2 | N | N | N | N | N | N | N | N | N | Y | Y | Y | Y | Y | Y 6 | Y 6 | Y | Y | Y | Y |
VMware vSphere Hypervisor (ESXi) 7.0 U3 | Y 1 | Y | Y | Y 1 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y 6 | Y 6 | Y | Y | Y | Y |
VMware vSphere Hypervisor (ESXi) 8.0 | Y 1 | Y | Y | Y 1 | Y | Y | N | N | N | Y | Y | Y | Y | Y | Y 6 | Y 6 | Y | Y | Y | Y |
VMware vSphere Hypervisor (ESXi) 8.0 U1 | Y 2 | Y | Y | Y 2 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y 6 | Y 6 | Y | Y | Y | Y |
VMware vSphere Hypervisor (ESXi) 8.0 U2 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y 6 | Y 6 | Y | Y | Y | Y |
1 For limitation, please refer Support Tip 103500, Support Tip 104324, Support Tip 104332
2 For limitation, please refer Support Tip 104278
3 For limitation, please refer Support Tip 103500, Support Tip 104324, Support Tip104332
4 For limitation, please refer Support Tip 103500, Support Tip 104324, Support Tip104333
5 For limitation, please refer Support Tip 104366
6 HW is not supported with EPYC 7002 processors.
Warranty
The adapters carry a 1-year limited warranty. When installed in a supported ThinkSystem server, the adapters assume the server’s base warranty and any warranty service upgrade.
Physical specification
The adapters have the following dimensions:
- Height: 64 mm (2.5 inches)
- Length: 167 mm (6.6 inches)
Operating environment
The adapters are supported in the following environment:
- Operating:
- Temperature: 0°C to 55°C (32°F to 131°F)
- Relative humidity: 10% to 90% (non-condensing)
- Altitude: Up to 3,000 meters
Agency approvals
The ThinkSystem 4350 HBAs have the following agency approvals:
- FCC Part 15 Class A
- Australia/New Zealand (AS/NZS 3548)
- Canada (ICES-003 Class B)
- Europe (EN55032/EN55024)
- Japan VCCI
- Korea KCC
- RoHS compliant
- EN/IEC/UL 60950
- USA (FCC 47 CFR part 15 Subpart B class B)
Related publications and links
For more information, see the following documents:
- Product publications:
- Lenovo ThinkSystem product publications:
http://thinksystem.lenovofiles.com/help/index.jsp - ServerProven hardware compatibility:
http://www.lenovo.com/us/en/serverproven - Lenovo ThinkSystem RAID Adapter and HBA Reference
https://lenovopress.com/lp1288-thinksystem-raid-adapter-and-hba-reference
Related product families
Product families related to this document are the following:
Trademarks
Lenovo and the Lenovo logo are trademarks or registered trademarks of Lenovo in the United States, other countries, or both. A current list of Lenovo trademarks is available on the Web at https://www.lenovo.com/us/en/legal/copytrade/.
The following terms are trademarks of Lenovo in the United States, other countries, or both:
Lenovo®
Bootable Media Creator
ServerProven®
ThinkSystem®
XClarity®
The following terms are trademarks of other companies:
Intel® and Xeon® are trademarks of Intel Corporation or its subsidiaries.
Linux® is the trademark of Linus Torvalds in the U.S. and other countries.
Microsoft®, Azure®, Windows Server®, and Windows® are trademarks of Microsoft Corporation in the United States, other countries, or both.
Other company, product, or service names may be trademarks or service marks of others.
Configure and Buy
Full Change History
Changes in the May 23, 2023 update:
- The adapters now support SED drives - Technical specifications section
Changes in the April 3, 2023 update:
- Updated the links to the hardware and software user guides, and added a link to the maxView Storage Manager user guide - Related publications and links section
Changes in the April 13, 2022 update:
- The adapters are currently not supported in a server with Intel E810 Ethernet adapter - Server support section
Changes in the August 31, 2021 update:
- Added links to the Installation Guide and Software User's Guide - Related publications and links section
First published: August 17, 2021