skip to main content

Lenovo ThinkEdge SE350 V2 Server

Product Guide

Home
Top

Abstract

The SE350 V2 is a purpose-built server that is half the width and significantly shorter than a traditional server, small footprint making it ideal for deployment in tight spaces. It can be mounted on a wall, ceiling mount, placed on a shelf or mounted in a rack. The ThinkEdge SE350 V2 server puts increased processing power, storage and network closer to where data is generated. For customers that want to install server outside data center looking for reduced latency by processing at the edge.

This product guide provides essential pre-sales information to understand the ThinkEdge SE350 V2 server, its key features and specifications, components and options, and configuration guidelines. This guide is intended for technical specialists, sales specialists, sales engineers, IT architects, and other IT professionals who want to learn more about the SE350 V2 and consider its use in IT solutions.

Change History

Changes in the April 25, 2024 update:

  • Updated part number under Mounting options section
    • ThinkEdge SE350 V2 Enclosure Shipping Bracket, 4XF7A94043

Introduction

The ThinkEdge SE350 V2 is a purpose-built server that is half the width and significantly shorter than a traditional server, making it ideal for deployment in tight spaces. It can be mounted on a wall, ceiling mount, placed on a desk or mounted in a rack. The ThinkEdge SE350 V2 puts increased processing power, storage and network closer to where data is generated, allowing actions resulting from the analysis of that data to take place more quickly.

Target workloads for the manufacturing, industrial and retail markets: hybrid clouds at the edge deployment, virtualization, NFV, workload consolidation, web host, management server, edge storage server.

SE350 V2
Figure 1. Lenovo ThinkEdge SE350 V2

Did you know?

The ThinkEdge SE350 V2 fits those customers that want to install a server outside the data center looking for reduced latency by processing at the edge, avoiding transmission of data between the core and edge where possible and also adhering to the regulatory security requirements of the geography and industry by storing and analyzing data at the edge. The ThinkEdge SE350 V2 has a compact design, low power usage, and high performance are just the right combination for edge locations. It can be wall mounted, placed on a desk or installed in a rack. It is also designed to operate in a semi rugged environment, 0°C to 55°C, dust and vibration.

Key features

The ThinkEdge SE350 V2 is a purpose-built server that is half the width and significantly shorter than a traditional server, making it ideal for deployment in tight spaces. The 3.2 liter case can be mounted on a wall, ceiling mount, placed on desk or mounted in a rack.

The ThinkEdge SE350 V2 puts increased processing power, storage and network closer to where data is generated, allowing actions resulting from the analysis of that data to take place more quickly. The server has wired connections up to 25GbE.

Since these edge servers are typically deployed outside of secure data centers, they include technology that encrypts the data stored on the device if it is tampered with, only enabling authorized users to access it.

Scalability and performance

The SE350 V2 offers numerous features to boost performance, improve scalability and reduce costs: 

  • Support a single processor from the Intel Xeon D Processor family. Supports processors up to 16 cores, core speeds of up to 2.1 GHz, and TDP ratings of up to 100W.
  • Intelligent and adaptive system performance with Intel Technology 2.0 allows processor cores to run at maximum speeds during peak workloads by temporarily going beyond processor TDP.
  • Intel Hyper-Threading Technology boosts performance for multithreaded applications by enabling simultaneous multithreading within each processor core, up to two threads per core.
  • Intel Virtualization Technology integrates hardware-level virtualization hooks that allow operating system vendors to better use the hardware for virtualization workloads.
  • Support for up to 4 TruDDR4 memory DIMMs an up to 256 GB of memory using 64 GB DIMMs.
  • Up to 4 x SATA/NVMe 2.5-inch 7mm HS drives; 2 x 2.5-inch 15mm HS drives.
  • Supports 1 or 2 additional M.2 NVMe drives for OS boot and applications (RAID 1), allowing the convenience of separating application code from data.
  • The use of NVMe drives increased performance over SATA drives, in terms of throughput, bandwidth, and latency.
  • 1GbE I/O board or 10 GbE/25GbE SFP28 I/O board to support low and high-speed networking to back-end servers.
  • No PCIe slot (no GPU support, no optional Network Adapters support).

Availability and serviceability

The SE350 V2 provides many features to simplify serviceability and increase system uptime:

  • Supports remote management, including remote control functions down to the UEFI level (most models) makes managing the edge servers easy even without onsite IT personnel.
  • ECC memory and memory RAS features.
  • Two redundant external AC Adapter power supplies and three fans to provide improved availability.
  • Built-in XClarity Controller continuously monitors system parameters, triggers alerts, and performs recovery actions in case of failures to minimize downtime.
  • Built-in diagnostics in UEFI, using Lenovo XClarity Provisioning Manager, speed up troubleshooting tasks to reduce service time.
  • Lenovo XClarity Provisioning Manager collects and saves service data to USB key drive or remote CIFS share folder, for troubleshooting and to reduce service time.
  • Auto restart in the event of a loss of AC power
  • Support for the XClarity Administrator Mobile app running on a supported smartphone and connected to the server through the service-enabled USB port, enables additional local systems management functions.
  • Three-year customer-replaceable unit and onsite limited warranty, 9 x 5 next business day. Optional service upgrades are available.

Manageability and security

Systems management features simplify local and remote management of the SE350 V2:

  • The server includes XClarity Controller 2 (XCC2) to monitor server availability. Optional upgrade to XCC Platinum to provide remote control (keyboard video mouse) functions, support for the mounting of remote media files (ISO and IMG image files), boot capture, power capping and new XCC2 Platinum features. New XCC2 Platinum features include System Guard, new security modes including a CNSA-compliant mode, FIPS 140-3 and NIST 800-193 support, and a new Neighbor Group feature.
  • Lenovo XClarity Administrator offers comprehensive hardware management tools that help to increase uptime, reduce costs and improve productivity through advanced server management capabilities.
  • IT Administrators can securely claim and activate the SE350 V2 remotely through the ThinkShield Key Vault Portal, available on the web. They can also manage and unlock their global IoT edge fleet for initial operation and in case of tamper. The ThinkShield Edge Mobile Management app enables Edge Users to securely claim and activate the ThinkSystem SE350 V2 in an easy to use Web UI.
  • New UEFI-based Lenovo XClarity Provisioning Manager, accessible from F1 during boot, provides system inventory information, graphical UEFI Setup, platform update function, RAID Setup wizard, operating system installation function, and diagnostic functions.
  • Support for Lenovo XClarity Energy Manager, which captures real-time power and temperature data from the server and provides automated controls to lower energy costs.
  • Integrated Trusted Platform Module (TPM) 2.0 support enables advanced cryptographic methods, such as digital signatures and remote attestation.
  • Supports Secure Boot to ensure only a digitally signed operating system can be used.
  • Industry-standard Advanced Encryption Standard (AES) NI support for faster, stronger encryption.
  • Intel Execute Disable Bit functionality can prevent certain classes of malicious buffer overflow attacks when combined with a supported operating system.
  • Intel Trusted Execution Technology provides enhanced security through hardware-based resistance to malicious software attacks, allowing an application to run in its own isolated space, protected from all other software running on a system.

View in Augmented Reality

View the SE350 V2 in augmented reality (AR) using your smartphone or tablet.

Simply follow these steps:

  1. Scan the QR code with the camera app on your phone*
  2. Point your phone at a flat surface
  3. Wait a few seconds for the model to appear

* If you're viewing this document on your phone or tablet, simply tap the QR code

Once the server appears, you can move your phone around it. You can also drag or rotate the server to reposition it.

3D Tour: ThinkEdge SE350 V2 Server augmented reality view

Components and connectors

The ports on the front of the ThinkEdge SE350 V2 server depend on which network module is installed.

The following figure shows server with the 1GbE network module installed. With this network module, the server has wired connectivity capabilities. Four 1GbE Ethernet ports, two 2.5 Gigabit Ethernet ports, and 1 port for management LAN.

Front view of the SE350 V2 with 1G network module
Figure 2. Front view of the ThinkEdge SE350 V2 server with 4 x 7mm 2.5” HS and 1GbE network module

The following figure shows server with the 10/25 GbE network module installed. With this network module, the server has wired connectivity capabilities. Four 10/25 GbE SFP28 ports, two 2.5 Gigabit Ethernet ports, and 1 port for management LAN.

Front view of the SE350 V2 with 10/25G network module
Figure 3. Front view of the ThinkEdge SE350 V2 server with 4 x 7mm 2.5” HS and 10/25 GbE network module

The following figure shows server with 1GbE module, 1GbE Ethernet ports, two 2.5 Gigabit Ethernet ports, and 1 port for management LAN.

SE350 V2 with 2x15mm drives

Figure 4. Front view of the ThinkEdge SE350 V2 server with 2 x 15mm 2.5” HS and 1GbE network module.

The following two figures show supported power options for the server.

Rear view of the Lenovo ThinkEdge SE350V2
Figure 5. Rear view of the ThinkEdge SE350 V2 with DC power

Rear view of the Lenovo ThinkEdge SE350V2 with AC power
Figure 6. Rear view of the ThinkEdge SE350 V2 with AC power

The following figure shows the locations of key components inside the server.

Internal view of the Lenovo ThinkEdge SE350V2
Figure 7. Internal view of the ThinkEdge SE350 V2

System architecture

The following figure shows the architectural block diagram of the SE350 V2 system, showing the major components and connections.

Tip: The wrench icons show where the local and remote management functions are enabled

SE350V2 system board block diagram

Figure 8. SE350 V2 system board - architectural block diagram

The system board connects to a network module which provides all wired network connections. Two network modules are offered. The block diagrams are shown in the following figures. All wired connections are at the front of the server.

SE350 V2 network modules block diagram

Figure 9. SE350 V2 network modules - architectural block diagrams

Standard specifications

The following table lists the standard specifications.

Table 1. Standard specifications
Components Specification
Machine types 7DA9 - SE350 V2 - 3 year warranty
7DBK - Lenovo ThinkEdge SE350 V2 1U2N and 2U2N Enclosure - 3 year warranty
Form factor Edge server, 1U high
Processor One Intel Xeon D-2700 Series processor (formerly codenamed "Icelake D"). Supports processors up to 16 cores, core speeds of up to 2.1 GHz, and TDP ratings of up to 100W. Processor is soldered onto system board.
Memory 4 DIMM slots. The processor has 4 memory channels, with 1 DIMM per channel. Lenovo TruDDR4 DIMMs operating at 3200 MHz. RDIMMs are supported
Memory maximum Up to 256GB with 4x 64 GB RDIMMs
Memory protection ECC, SDDC (for x4-based memory DIMMs)
Drive bays

2.5-inch 7mm drive bays:

  • Up to 4x 2.5-inch 7mm hot-swap bays (NVMe/SATA)

2.5-inch 15mm drive bays:

  • Up to 2x 2.5-inch 15mm hot-swap bays (NVMe)

 Internal drives for OS boot:

  • I/O module supporting up to two 2280 NVMe M.2 drives
Maximum data storage

NVMe drives:

  • 15.36 TB using 2x 7.68TB 15mm NVMe drives or 4x 3.84 7mm NVMe drives

SATA drives:

  • 30.72TB using 4x7.68TB 7mm SATA drives
Storage controller
  • Boot drives:
    • Onboard NVMe controller supporting RAID 0, 1 (with Intel VROC RAID support)
  • Data drives:
    • Onboard SATA/NVMe controller supporting RAID 0, 1, 5, 10 (with Intel VROC RAID support)
Network interfaces

Networking depends the network module selected:

  • 10/25GbE I/O module
    • 4x 25GbE or 10GbE SFP28 ports (depends on CPU), 2x 2.5GbE RJ45 ports, 1x 1GbE RJ45 dedicated port for remote management.
  • 1GbE I/O module
    • 4x 1GbE RJ45 ports, 2x 2.5GbE RJ45 ports, 1x 1GbE RJ45 dedicated port for remote management.
PCI Expansion slots None
Ports

Front: 2x USB 3.2 G1 Type-A ports, 1x USB 3.2 G1 Type-C port (for display), 1x USB 2.0 G1 Type-C port for local systems management.

Rear: power connectors, 1x RJ-45 RS-232 serial console connector, PMB status LED, 2x threaded studs for grounding. 

Cooling Three non-hot-swap 40 mm fans (all 3 standard), N+1 redundant in most configurations.
Video Embedded graphics with 16 MB memory with 2D hardware accelerator, integrated into the XClarity Controller 2 management controller. Maximum resolution is 1920x1200 32bpp at 60Hz.
Power supply

Choices for power input:

  • AC Power Cord to external 300W adapter mode (5°C to 40°C with node, 5°C to 30°C on rack)
  • DC using Direct Connection (12-48V) (0°C to 55°C)
  • Pure AC Input Mode (0°C to 55°C)
Systems management Operator panel with status LEDs. Dedicated ports for local management (USB type-C for use with mobile app) and remote management (RJ45 Ethernet ports). Remote management can also be performed. XClarity Controller 2 (XCC2) embedded management controller, XClarity Administrator centralized infrastructure delivery, XClarity Integrator plugins, and XClarity Energy Manager centralized server power management. Optional XClarity Controller Advanced to enable remote control functions. ThinkShield Edge Mobile Management mobile app and XClarity Mobile app for local onsite SE350 V2 server management.
Security features ThinkShield Key Vault Portal web site for security management. Trusted Platform Module, supporting TPM 2.0. In China only, optional Nationz TPM 2.0. Front Security bezel, Kensington cable slot with intelligent lock position switch, G-sensor trigger for motion detection, intrusion detection, self-encrypting drive (SED) support, power-on password, administrator's password.
Operating systems supported Microsoft Windows Server, Red Hat Enterprise Linux, SUSE Linux Enterprise Server, VMware ESXi. Ubuntu Server certification. See the Operating system support section for specifics.
Mounting options DIN rail wall mount, ceiling mount, 1U rack mount (2 servers), 2U short-depth rack mount (2 servers). Available Security bezel with dust filter.
Limited warranty Three-year customer-replaceable unit and onsite limited warranty with 9x5 next business day (NBD).
Service and support Optional service upgrades are available through Lenovo Services: 4-hour or 2-hour response time, 6-hour fix time, 1-year or 2-year warranty extension, software support for Lenovo hardware and some third-party applications.
Dimensions Height: 41.7 mm (1.64 in.), width: 209 mm (8.23 in.), depth: 384 mm (15.12 in.)
Volume 3.2 liters
Weight Maximum: 3.75 kg (8.3 lb)

Models

ThinkEdge SE350 V2 models can be configured by using the Lenovo Data Center Solution Configurator (DCSC).

Configure-to-order (CTO) models are used to create models with factory-integrated server customizations. One CTO model is available for the SE350 V2 as listed in the following table:

  • The CTO1WW base CTO model is for general business and is selectable by choosing General Purpose mode in DCSC.
Table 2. Base CTO models
Description Machine Type/Model
General purpose
ThinkEdge SE350 V2 - 3 year Warranty 7DA9CTO1WW
Lenovo ThinkEdge SE350 V2 1U2N Enclosure 7DBKCTO1WW
Lenovo ThinkEdge SE350 V2 2U2N Enclosure 7DBKCTO2WW

Processors

The SE350 V2 supports processors in the Intel Xeon D-2700 family of processors (formerly codenamed "Icelake D"). The server supports one processor and the processor is soldered on the system board.

The table below lists the supported processors.

All supported processors have the following characteristics:

  • AI capable: Intel AVX-512, VNNI, OpenVINO
  • Intel Turbo Boost 3.1
  • Intel Hyper-Threading Technology 
  • Intel Virtualization Technology (VT-c, VT-x, VT-d) 
  • Intel AES New Instructions
  • Intel Trusted Execution Technology
  • Converged Boot Guard (CBnT)
  • Intel Software Guard Extensions (SGX)
  • Intel Boot Guard
  • Faster Boot with Slim Bootloader
  • Time Coordinated Computing (TCC)

Part numbers: There are no part numbers for processors because there are no field upgrades supported.

Table 3. Processor options for the SE350 V2
Feature code* Description
BS3V / BS40 ThinkEdge SE350 V2/SE360 V2 Planar with Intel Xeon D-2712T 4C 65W 1.9 GHz
BS3W / BS41 ThinkEdge SE350 V2/SE360 V2 Planar with Intel Xeon D-2733NT 8C 80W 2.1 GHz
BS3X/ BS42 ThinkEdge SE350 V2/SE360 V2 Planar with Intel Xeon D-2775TE 16C 100W 2.0 GHz

* The second feature code is for CTO orders from NA and LA geographies, and for Brazil

The following table lists the features of the supported processors.

Table 4. Processor specifications
Intel model Cores /
Threads
HT TB Base
Frequency
Max Turbo
Frequency
L3 Cache Ethernet mode Memory
channels
Memory
bus
TDP
D-2712T Y Y 1.90 GHz 3.0 GHz 15 MB 50 G 4 2667 MHz 65 W
D-2733NT Y Y 2.10 GHz 3.2 GHz 15 MB 50 G 4 2667 MHz 80 W
D-2775TE 16  Y Y 2.00 GHz 3.1 GHz 25 MB 100 G 4 2933 MHz 100 W

Note: 10/25GbE I/O module LAN speed depend on CPU ethernet mode, 4x 10GbE (max 50 G) or 4x 25GbE (max 100G)
Note: 20-core processor support: The processors listed here have up to 16 cores. The server also supports 20-core processors, however these are currently only available via special bid/CORE. Please contact your Lenovo sales representative. 
 

Memory options

The server uses processors with 4 memory channels and supports 1 DIMM per channel, for a total of 4 DIMMs. The server supports up to 256GB of memory using 4x 64 GB RDIMMs.

The following table lists the memory options that are available for the server.

Lenovo TruDDR4 memory uses the highest quality components that are sourced from Tier 1 DRAM suppliers and only memory that meets the strict requirements of Lenovo is selected. It is compatibility tested and tuned to maximize performance and reliability. From a service and support standpoint, Lenovo TruDDR4 memory automatically assumes the system warranty, and Lenovo provides service and support worldwide.

Table 5. Supported memory options
Part
number
Feature
code
Description Minimum
supported
Maximum
supported
RDIMMs
4X77A08634 B965 ThinkSystem 32GB TruDDR4 3200 MHz (2Rx8 1.2V) RDIMM 1 4
4X77A08633 B964 ThinkSystem 32GB TruDDR4 3200 MHz (2Rx4 1.2V) RDIMM 1 4
4X77A08632 B963 ThinkSystem 16GB TruDDR4 3200 MHz (2Rx8 1.2V) RDIMM 1 4
4X77A08635 B966 ThinkSystem 64GB TruDDR4 3200 MHz (2Rx4 1.2V) RDIMM 1 4

 

The following rules apply when selecting the memory configuration:

  • DIMM installation sequence 1, 4, 2 & 3
  • One DIMM per channel only
  • Three DIMMs are not supported
  • The server supports RDIMMs
  • Mix of 2Rx4 and 2Rx8 based DIMMs across channels are not supported
  • Mix of 16GB 2Rx8 & 32GB 2Rx8 across channels are supported
  • Mix of 32GB 2Rx4 & 64GB 2Rx4 across channels are supported
  • Memory mirroring and memory rank sparing are not supported
  • Server supports Independent mode
  • Rank sparing, ADDC, channel mirroring, hemisphere modes, and 2LM are not supported with Software Guard Extensions (SGX) 

The following memory protection technologies are supported:

  • ECC detection/correction
  • SDDC (for x4-based memory DIMMs; look for "x4" in the DIMM description)

I/O expansion

The SE350 V2 does not support PCIe I/O slots.

Internal storage

The internal storage of the SE350 V2 server is implemented as follows:

  • Up to 4x SATA/NVMe 2.5-inch 7mm drives or 2x NVMe 2.5-inch 15mm drives.
  • NVMe 2.5-inch drives with PCIe 4.0 interface.
  • Boot drives are installed on I/O module with dedicated slot, either one or two 2280 NVMe M.2 drives with PCIe gen3 are supported.

The following modules are supported.

Table 6. SSD module options
Part
number
Feature
code
Description 7mm SSD 15mm SSD
4XF7A86281 BS48 ThinkEdge SE350 V2 7mm SSD Module 0-4 (NVMe/SATA) --
4XF7A86280 BS47 ThinkEdge SE350 V2 15mm SSD Module -- 0-2 (all NVMe)

Controllers for internal storage

The SE350 V2 supports the following for internal storage:

  • Onboard NVMe controller supporting RAID 0, 1 (with Intel VROC RAID support) - boot drives
  • Onboard SATA/NVMe controller supporting RAID 0, 1, 5, 10 (with Intel VROC RAID support) - data drives

Intel VROC onboard RAID

Intel VROC (Virtual RAID on CPU) is a feature of the Intel processor that enables RAID support.
There are two separate functions of VROC in the SE350 V2:

  • Intel VROC SATA RAID, formerly known as Intel RSTe
  • Intel VROC NVMe RAID

VROC SATA RAID (RSTe) is available and supported with all SATA drives, both SATA SSDs and SATA HDDs. It offers a 6 Gb/s connection to each drive and on the SE350 V2 implements RAID levels 0, 1, 5, and 10. RAID 1 is limited to 2 drives per array, and RAID 10 is limited to 4 drives per array. Hot-spare functionality is also supported.

VROC NVMe RAID offers RAID support for any NVMe drives directly connected to the ports on the server's
system board. On the SE350 V2, it implements RAID levels 0, 1, 5, and 10. RAID 1 is limited to 2 drives per array, and RAID 10 is limited to 4 drives per array. Hot-spare functionality is also supported.

The following options are available as follows:

  • VROC NVMe RAID on the SE350 V2 by default is disabled and does not support NVMe RAID. In configurator selecting "none" would mean default, same as JBOD. 
  • Selecting VROC Standard, feature code BR9B, to support  RAID-0/1/10.
  • Selecting VROC Premium, feature code B96G, to support RAID-0/1/5/10.

VROC Standard or Premium are fulfilled as a Feature on Demand (FoD) license and is activated via the XCC management processor user interface.

Table 7. VROC upgrade
Part
number
Feature
code
Description
4L47A39164 B96G / BS7N Intel VROC (VMD NVMe RAID) Premium
4L47A83669 BR9B / BS7M Intel VROC (VMD NVMe RAID) Standard

 

VROC Premium is only needed on the SE350 V2 for RAID-5 support with NVMe drives. You do not need the VROC Premium license upgrade under any of the following conditions:

  • If you have SATA drives connected to the onboard SATA ports, you do not need VROC Premium.
  • If you are using RAID 0, 1 or 10 with NVMe drives, you do not need VROC Premium.

Virtualization support: Virtualization support for Intel VROC is as follows:

  • VROC SATA RAID (RSTe): VROC SATA RAID is not supported by virtualization hypervisors such as ESXi, KVM, Xen, and Hyper-V. Virtualization is only supported on the onboard SATA ports in AHCI (non-RAID) mode.
  • VROC (VMD) NVMe RAID: VROC (VMD) NVMe RAID is supported by ESXi, KVM, Xen, and Hyper-V. ESXi support is limited to RAID 1 only; other RAID levels are not supported. Windows and Linux OSes support VROC RAID NVMe, both for host boot functions and for guest OS function, and RAID-0, 1, 5, and 10 are supported.

Internal drive options

The SE350 V2 supports the following type of drive bays.

  • 2.5-inch 7mm drive bays:
    • 7mm 2.5-inch hot-swap 6 Gb SATA SSDs
    • 7mm 2.5-inch hot-swap PCIe 4.0 NVMe SSDs
  • 2.5-inch 15mm drive bays:
    • 15mm 2.5-inch hot-swap PCIe 4.0 NVMe SSDs
  • M.2 drives for boot:
    • 2280 NVMe M.2 drives

The following table lists the supported drive options.

Table 8. Supported list of drives
Part
number
Feature
code
Description Max
Qty
7mm 2.5-inch hot-swap 6 Gb SATA SSDs
4XB7A17106 BK79 ThinkSystem 7mm S4520 240GB Read Intensive SATA 6Gb HS SSD 4
4XB7A17107 BK7A ThinkSystem 7mm S4520 480GB Read Intensive SATA 6Gb HS SSD 4
4XB7A17108 BK7B ThinkSystem 7mm S4520 960GB Read Intensive SATA 6Gb HS SSD 4
4XB7A78622 BM8E ThinkSystem 7mm S4520 1.92TB Read Intensive SATA 6Gb HS SSD 4
4XB7A78623 BM8D ThinkSystem 7mm S4520 3.84TB Read Intensive SATA 6Gb HS SSD 4
4XB7A78624 BM8C ThinkSystem 7mm S4520 7.68TB Read Intensive SATA 6Gb HS SSD 4
4XB7A82264 BQ1U ThinkSystem 7mm 5400 PRO 240GB Read Intensive SATA 6Gb HS SSD 4
4XB7A82265 BQ1V ThinkSystem 7mm 5400 PRO 480GB Read Intensive SATA 6Gb HS SSD 4
4XB7A82266 BQ1W ThinkSystem 7mm 5400 PRO 960GB Read Intensive SATA 6Gb HS SSD 4
4XB7A82267 BR13 ThinkSystem 7mm 5400 PRO 1.92TB Read Intensive SATA 6Gb HS SSD 4
4XB7A82268 BR12 ThinkSystem 7mm 5400 PRO 3.84TB Read Intensive SATA 6Gb HS SSD 4
4XB7A82269 BR11 ThinkSystem 7mm 5400 PRO 7.68TB Read Intensive SATA 6Gb HS SSD 4
7mm 2.5-inch hot-swap PCIe 4.0 NVMe SSDs
4XB7A82851 BS45 ThinkSystem 7mm U.3 7450 MAX 800GB Mixed Use NVMe PCIe 4.0 x4 HS SSD 4
4XB7A82853 BPZ4 ThinkSystem 7mm U.3 7450 PRO 960GB Read Intensive NVMe PCIe 4.0 x4 HS SSD 4
4XB7A82855 BPZ5 ThinkSystem 7mm U.3 7450 PRO 1.92TB Read Intensive NVMe PCIe 4.0 x4 HS SSD 4
4XB7A82856 BPZ6 ThinkSystem 7mm U.3 7450 PRO 3.84TB Read Intensive NVMe PCIe 4.0 x4 HS SSD 4
15mm 2.5-inch hot-swap PCIe 4.0 NVMe SSDs
4XB7A13941 BMGD ThinkSystem 2.5" U.2 P5520 1.92TB Read Intensive NVMe PCIe 4.0 x4 HS SSD 2
4XB7A13942 BMGE ThinkSystem 2.5" U.2 P5520 3.84TB Read Intensive NVMe PCIe 4.0 x4 HS SSD 2
4XB7A13943 BNEF ThinkSystem 2.5" U.2 P5520 7.68TB Read Intensive NVMe PCIe 4.0 x4 HS SSD 2
4XB7A17129 BNEG ThinkSystem 2.5" U.2 P5620 1.6TB Mixed Use NVMe PCIe 4.0 x4 HS SSD 2
4XB7A17130 BNEH ThinkSystem 2.5" U.2 P5620 3.2TB Mixed Use NVMe PCIe 4.0 x4 HS SSD 2
4XB7A17160 BMM8 ThinkSystem 2.5" U.2 P5800X 1.6TB Write Intensive NVMe PCIe 4.0 x4 HS SSD 2
4XB7A13967 BNEJ ThinkSystem 2.5" U.3 7450 MAX 1.6TB Mixed Use NVMe PCIe 4.0 x4 HS SSD 2
4XB7A13970 BNEY ThinkSystem 2.5" U.3 7450 MAX 3.2TB Mixed Use NVMe PCIe 4.0 x4 HS SSD 2
4XB7A79647 BNF2 ThinkSystem 2.5" U.3 7450 PRO 1.92TB Read Intensive NVMe PCIe 4.0 x4 HS SSD 2
4XB7A79648 BNF5 ThinkSystem 2.5" U.3 7450 PRO 3.84TB Read Intensive NVMe PCIe 4.0 x4 HS SSD 2
4XB7A79649 BNF4 ThinkSystem 2.5" U.3 7450 PRO 7.68TB Read Intensive NVMe PCIe 4.0 x4 HS SSD 2
2280 NVMe M.2 drives
4XB7A82674 BQUJ ThinkSystem M.2 7450 PRO 960GB Read Intensive NVMe PCIe 4.0 x4 NHS SSD (with Heatsink) 2
4XB7A83139 BS46 ThinkSystem M.2 7450 PRO 480GB Read Intensive NVMe PCIe 4.0 x4 NHS SSD (with Heatsink) 2
M.2 N-30m2 Read Intensive NVMe PCIe 3.0 x4 NHS SSD 
4XB7A90722 BYLN ThinkSystem M.2 N-30m2 1.92TB Read Intensive NVMe PCIe 3.0 x4 NHS SSD (Industrial) 2
4XB7A90721 BYLM ThinkSystem M.2 N-30m2 960GB Read Intensive NVMe PCIe 3.0 x4 NHS SSD (Industrial) 2
4XB7A90720 BYLL ThinkSystem M.2 N-30m2 480GB Read Intensive NVMe PCIe 3.0 x4 NHS SSD (Industrial) 2

Optical drive

The server supports the external USB optical drive listed in the following table.

Table 9. External optical drive
Part number Feature code Description
7XA7A05926 AVV8 ThinkSystem External USB DVD RW Optical Disk Drive

The drive is based on the Lenovo Slim DVD Burner DB65 drive and supports the following formats: DVD-RAM, DVD-RW, DVD+RW, DVD+R, DVD-R, DVD-ROM, DVD-R DL, CD-RW, CD-R, CD-ROM.

Network Modules

The network ports on the front of the SE350 V2 are provided by a Network Module, a board that plugs into the system board by a dedicated connector. See the Internal view for the location of the connector. The Network Modules are listed in the following table.

Table 10. Network Modules
Part number Feature code Description
CTO only BS3U

SE350 V2 1Gbx4 I/O Module board

CTO only BS3T

SE350 V2 25G/10G IO Module board

The Network Modules have the following characteristics:

  • 1GbE I/O module board
    • Two USB 3.2 Gen 1 Type-A connectors
    • USB 3.2 Gen 1 Type-C connector (supporting display)
    • USB 2.0 Gen 1 Type-C connector with Lenovo XClarity Controller (XCC) management
    • One XCC system management port (1GbE RJ-45)
    • Four 1GbE RJ-45 connectors
    • Two 2.5GbE RJ-45 connectors
    • 2.5G RJ45 ports support 1G speed with LED normal behavior
    • Note:
      • 2.5Gb RJ45 ports support 100Mbps data transfer, but link speed LED keep dark, do not support 10Mbps. 
      • 1Gb RJ45 port support 100M bps if link peer does not force speed on 100Mbps since Icelake D doesn’t support 100M half-duplex and link LED is always green status, while ACT LED keeps green and wont blinking when transferring data; do not support 10Mbps
  • 10/25GbE SFP28 I/O module board
    • Two USB 3.2 Gen 1 Type-A connectors
    • USB 3.2 Gen 1 Type-C connector (supporting display)
    • USB 2.0 Gen 1 Type-C connector with Lenovo XClarity Controller (XCC) management
    • One XCC system management port (1GbE RJ-45)
    • Four 10/25GbE SFP28 connectors
    • Two 2.5GbE RJ-45 connectors
    • No support for 10 Mbps / 100 Mbps speeds

Note: When the shipping bracket is installed, the front operator panel is not accessible.

The network modules are shown in the following figure.

SE350V2 Network Modules
Figure 10. Ports of the available Network Modules

The block diagrams of the Network Modules are shown in the System architecture section.

The specifications of the connections in the two Wired Network Modules are as follows:

  • Front IO with 25G/10G x4
    • Front Op-Panel
    • 4x 10Gb/25Gb SFP28 (SFP28 from CPU embedded LAN)
    • 2x 2.5Gb RJ45 (RJ45 from intel I226)
    • 1x XCC Management Port (dedicate RJ45 Management port for XCC)
    • 1x USB Type-C port (USB Management port for XCC)
    • 1x USB Type-C port (USB 3.0/2.0 from CPU for display)
    • 2x USB Type-A port (USB 3.0/2.0 from CPU)
  • Front IO with 1G x4
    • Front Op-Panel
    • 4x 1Gb RJ45 (RJ45 from CPU embedded LAN)
    • 2x 2.5Gb RJ45 (RJ45 from intel I226)
    • 1x XCC Management Port (dedicated RJ45 Management port for XCC)
    • 1x USB Type-C port (USB Management port for XCC)
    • 1x USB Type-C port (USB 3.0/2.0 from CPU for display)
    • 2x USB Type-A port (USB 3.0/2.0 from CPU)

The SFP28 ports in the Wired Network Module support the transceivers listed in the following table.

Table 11. Transceivers for Network Modules
Part number Feature code Description
10Gb transceivers
4TC7A78615 BNDR ThinkSystem Accelink 10G SR SFP+ Ethernet transceiver
46C3447 5053 SFP+ SR Transceiver
00MY034 ATTJ Lenovo Dual Rate 1G/10GB SFP Transceiver
25Gb transceivers
4M27A67041 BFH2 Lenovo 25Gb SR SFP28 Ethernet Transceiver
7G17A03537 AV1B Lenovo Dual Rate 10G/25G SR SFP28 Transceiver

The SFP28 ports of the Network Modules support the following fiber optic cables and direct-attach copper (DAC) cables.

Table 12. Optical cables and DAC cables
Part number Feature code Description
LC-LC OM3 Fiber Optic Cables (these cables require a 10 GbE SFP+ SR transceiver)
00MN499 ASR5 Lenovo 0.5m LC-LC OM3 MMF Cable
00MN502 ASR6 Lenovo 1m LC-LC OM3 MMF Cable
00MN505 ASR7 Lenovo 3m LC-LC OM3 MMF Cable
00MN508 ASR8 Lenovo 5m LC-LC OM3 MMF Cable
00MN511 ASR9 Lenovo 10m LC-LC OM3 MMF Cable
00MN514 ASRA Lenovo 15m LC-LC OM3 MMF Cable
00MN517 ASRB Lenovo 25m LC-LC OM3 MMF Cable
00MN520 ASRC Lenovo 30m LC-LC OM3 MMF Cable
OM4 LC to LC Cables (these cables require a transceiver)
4Z57A10845 B2P9 Lenovo 0.5m LC-LC OM4 MMF Cable
4Z57A10846 B2PA Lenovo 1m LC-LC OM4 MMF Cable
4Z57A10847 B2PB Lenovo 3m LC-LC OM4 MMF Cable
4Z57A10848 B2PC Lenovo 5m LC-LC OM4 MMF Cable
4Z57A10849 B2PD Lenovo 10m LC-LC OM4 MMF Cable
4Z57A10850 B2PE Lenovo 15m LC-LC OM4 MMF Cable
4Z57A10851 B2PF Lenovo 25m LC-LC OM4 MMF Cable
4Z57A10852 B2PG Lenovo 30m LC-LC OM4 MMF Cable
SFP+ 10Gb Passive DAC Cables
00AY764 A51N 1.5m Passive DAC SFP+ Cable
00AY765 A51P 2m Passive DAC SFP+ Cable
90Y9430 A1PJ 3m Passive DAC SFP+ Cable
25G SFP28 Active Optical Cables
7Z57A03541 AV1F Lenovo 3m 25G SFP28 Active Optical Cable
7Z57A03542 AV1G Lenovo 5m 25G SFP28 Active Optical Cable
7Z57A03543 AV1H Lenovo 10m 25G SFP28 Active Optical Cable
7Z57A03544 AV1J Lenovo 15m 25G SFP28 Active Optical Cable
7Z57A03545 AV1K Lenovo 20m 25G SFP28 Active Optical Cable
100G QSFP28 Breakout Active Optical Cables
7Z57A03551 AV1R Lenovo 3m 100G to 4x25G Breakout Active Optical Cable
7Z57A03552 AV1S Lenovo 5m 100G to 4x25G Breakout Active Optical Cable
7Z57A03553 AV1T Lenovo 10m 100G to 4x25G Breakout Active Optical Cable
7Z57A03554 AV1U Lenovo 15m 100G to 4x25G Breakout Active Optical Cable
7Z57A03555 AV1V Lenovo 20m 100G to 4x25G Breakout Active Optical Cable

The following table lists the direct-attach copper (DAC) cables that are supported in the 25GbE port.

Table 13. Copper cables
Part number Feature code Description
SFP+ 10Gb Passive DAC Cables
00D6288 A3RG 0.5m Passive DAC SFP+ Cable
90Y9427 A1PH 1m Passive DAC SFP+ Cable
00AY764 A51N 1.5m Passive DAC SFP+ Cable
00AY765 A51P 2m Passive DAC SFP+ Cable
90Y9430 A1PJ 3m Passive DAC SFP+ Cable
90Y9433 A1PK 5m Passive DAC SFP+ Cable
00D6151 A3RH 7m Passive DAC SFP+ Cable
SFP28 25Gb Passive DAC Cables
7Z57A03557 AV1W Lenovo 1m Passive 25G SFP28 DAC Cable
7Z57A03558 AV1X Lenovo 3m Passive 25G SFP28 DAC Cable
7Z57A03559 AV1Y Lenovo 5m Passive 25G SFP28 DAC Cable
QSFP28 100G-to-4x25G Breakout Cables
7Z57A03564 AV22 Lenovo 1m 100G QSFP28 to 4x25G SFP28 Breakout DAC Cable
7Z57A03565 AV23 Lenovo 3m 100G QSFP28 to 4x25G SFP28 Breakout DAC Cable
7Z57A03566 AV24 Lenovo 5m 100G QSFP28 to 4x25G SFP28 Breakout DAC Cable

The RJ45 ports of the Network Modules support the following Category 6 (CAT 6) cables.

Table 14. CAT6 cables
Part number Feature code Description
CAT6 Green Cables
00WE123 AVFW 0.75m CAT6 Green Cable
00WE127 AVFX 1.0m CAT6 Green Cable
00WE131 AVFY 1.25m CAT6 Green Cable
00WE135 AVFZ 1.5m CAT6 Green Cable
00WE139 AVG0 3m CAT6 Green Cable
90Y3715 A1MS 10m Yellow Cat6 Cable
90Y3718 A1MT 10m Green Cat6 Cable
90Y3721 A1MU 10m Blue Cat6 Cable
90Y3724 A1MV 25m Yellow Cat6 Cable
90Y3727 A1MW 25m Green Cat6 Cable
90Y3730 A1MX 25m Blue Cat6 Cable
CAT6 RJ45/RJ45
4X97A83980 BRW9 Lenovo 750mm Cat6 RJ45 White Cable without Jacket
4X97A83981 BRWA Lenovo 1000mm Cat6 RJ45 White Cable without Jacket
4X97A83982 BRWB Lenovo 1250mm Cat6 RJ45 White Cable without Jacket
4X97A83983 BRWC Lenovo 1500mm Cat6 RJ45 White Cable without Jacket
4X97A83984 BRWD Lenovo 3000mm Cat6 RJ45 White Cable without Jacket

Network adapters

The SE350 V2 does not support additional network adapters. There is no PCIe slot available.

GPU adapters

The SE350 V2 does not support any graphics processing units (GPUs). There is no PCIe slot available.

Cooling

The SE350 V2 server has three 40 mm non-hot-swap fans. All three are standard and support N+1 redundancy.

Power supplies

The SE350 V2 supports three type of power input path as following components and options:

  • AC Power Cord to external 300W adapter mode (5°C to 40°C)
    • Details regarding the use of AC adapters:
      • One or two AC adapters are supported.
      • When two AC adapters are connected, the second AC adapter is redundant.
      • In case of failure of an AC adapter, system will throttle if power budget is above adapter capacity.
      • To connect AC Adapters to system directly a bridge cable is required.
      • AC Adapters do not include a line cord. See the next section for available power cords.
  • DC using Direct Connection (12-48V) (0°C to 55°C)
    • Details regarding the use of DC power:
      • One or two DC power input source are supported.
      • When two DC power input are connected, the second DC input is redundant.
      • In case of failure of DC input, system will throttle if power budget is above DC input capacity.
      • DC Terminal block cable for DC power source connection with system.
  • Pure AC Input Mode (0°C to 55°C)
    • Details regarding the use of AC power:
      • One AC power input source is supported only.
      • Pure AC input do not support power redundant and is non-hot swap.
      • Power supply do not include a line cord. See the next section for available power cords.

Ordering information is listed in the following table.

Table 15. Power options
Part number Feature code Description Maximum
supported
AC Power Cord to external 300W adapter mode
CTO only BU98 ThinkEdge SE350 V2 12-48V DC Power Module Board 1
CTO only BS4A ThinkEdge SE350 V2 DC Power Input Board 1
4X27A88607 BW2K ThinkEdge 300W 230V/115V External Power Supply 2
4X97A88737 BW2I ThinkEdge SE350 V2 External 300W Bridge Cable 2
DC using Direct Connection (12-48V)
CTO only BU98 ThinkEdge SE350 V2 12-48V DC Power Module Board 1
CTO only BS4A ThinkEdge SE350 V2 DC Power Input Board 1
4L67A91004 BS4C ThinkEdge SE350 V2 External DC Terminal Block Cable 2
Pure AC Input Mode
CTO only BUGP ThinkEdge SE350 V2 AC Power Input Board 1
CTO only BWK7 ThinkEdge SE350 V2 500W 230V/115V Non-Hot Swap Power Supply 1

Power cords

Line cords and rack power cables can be ordered as listed in the following table.

Table 16. Power cords
Part number Feature code Description 
Power cord for AC adapters
39Y7930 6222 2.8m, 10A/250V, C13 to IRAM 2073 (Argentina) Line Cord
81Y2384 6492 4.3m 10A/220V, C13 to IRAM 2073 (Argentina) Line Cord
39Y7924 6211 2.8m, 10A/250V, C13 to AS/NZ 3112 (Australia/NZ) Line Cord
81Y2383 6574 4.3m, 10A/230V, C13 to AS/NZS 3112 (Aus/NZ) Line Cord
69Y1988 6532 2.8m, 10A/250V, C13 to NBR 14136 (Brazil) Line Cord
81Y2387 6404 4.3m, 10A/250V, C13 - 2P+Gnd (Brazil) Line Cord
39Y7928 6210 2.8m, 220-240V, C13 to GB 2099.1 (China) Line Cord
81Y2378 6580 4.3m, 10A/220V, C13 to GB 2099.1 (China) Line Cord
39Y7918 6213 2.8m, 10A/250V, C13 to DK2-5a (Denmark) Line Cord
81Y2382 6575 4.3m, 10A/230V, C13 to DK2-5a (Denmark) Line Cord
39Y7917 6212 2.8m, 10A/230V, C13 to CEE7-VII (Europe) Line Cord
81Y2376 6572 4.3m, 10A/230V, C13 to CEE7-VII (Europe) Line Cord
39Y7927 6269 2.8m, 10A/250V, C13(2P+Gnd) (India) Line Cord
81Y2386 6567 4.3m, 10A/240V, C13 to IS 6538 (India) Line Cord
39Y7920 6218 2.8m, 10A/250V, C13 to SI 32 (Israel) Line Cord
81Y2381 6579 4.3m, 10A/230V, C13 to SI 32 (Israel) Line Cord
39Y7921 6217 2.8m, 220-240V, C13 to CEI 23-16 (Italy/Chile) Line Cord
81Y2380 6493 4.3m, 10A/230V, C13 to CEI 23-16 (Italy/Chile) Line Cord
46M2593 A1RE 2.8m, 12A/125V, C13 to JIS C-8303 (Japan) Line Cord
4L67A08357 6533 2.8m, 200V, C13 to JIS C-8303 (Japan) Line Cord
39Y7926 6335 4.3m, 12A/100V, C13 to JIS C-8303 (Japan) Line Cord
4L67A08362 6495 4.3m, 12A/200V, C13 to JIS C-8303 (Japan) Line Cord
39Y7922 6214 2.8m, 10A/250V, C13 to SABS 164 (S Africa) Line Cord
81Y2379 6576 4.3m, 10A/230V, C13 to SABS 164 (South Africa) Line Cord
39Y7925 6219 2.8m, 220-240V, C13 to KETI (S Korea) Line Cord
81Y2385 6494 4.3m, 12A/220V, C13 to KSC 8305 (S. Korea) Line Cord
39Y7919 6216 2.8m, 10A/250V, C13 to SEV 1011-S24507 (Swiss) Line Cord
81Y2390 6578 4.3m, 10A/230V, C13 to SEV 1011-S24507 (Sws) Line Cord
23R7158 6386 2.8m, 10A/125V, C13 to CNS 10917-3 (Taiwan) Line Cord
81Y2375 6317 2.8m, 10A/240V, C13 to CNS 10917-3 (Taiwan) Line Cord
4L67A08363 AX8B 4.3m, 10A 125V, C13 to CNS 10917 (Taiwan) Line Cord
81Y2389 6531 4.3m, 10A/250V, C13 to 76 CNS 10917-3 (Taiwan) Line Cord
39Y7923 6215 2.8m, 10A/250V, C13 to BS 1363/A (UK) Line Cord
81Y2377 6577 4.3m, 10A/230V, C13 to BS 1363/A (UK) Line Cord
90Y3016 6313 2.8m, 10A/120V, C13 to NEMA 5-15P (US) Line Cord
4L67A08359 6370 4.3m, 10A/125V, C13 to NEMA 5-15P (US) Line Cord
4L67A08361 6373 4.3m, 10A/250V, C13 to NEMA 6-15P (US) Line Cord
46M2592 A1RF 2.8m, 10A/250V, C13 to NEMA 6-15P Line Cord
Rack jumper cables for AC adapters
SL67B08593 BPHZ 0.5m, 10A/100-250V, C13 to C14 Jumper Cord
00Y3043 A4VP 1.0m, C13 to C14 Jumper Cord, Rack Power Cable
4L67A08365 B0N4 2.0m, 10A/100-250V, C13 to C14 Jumper Cord
4L67A08366 6311 2.8m, 10A/100-250V, C13 to C14 Jumper Cord
39Y7937 6201 1.5m, 10A/100-250V, C13 to IEC 320-C14 Rack Power Cable
39Y7932 6263 4.3m, 10A/100-250V, C13 to IEC 320-C14 Rack Power Cable
Rack Y-type jumper cables for AC adapters
00Y3046 A4VQ 1.345m, 2X C13 to C14 Jumper Cord, Rack Power Cable
00Y3047 A4VR 2.054m, 2X C13 to C14 Jumper Cord, Rack Power Cable

Systems management

The SE350 V2 contains an integrated service processor, XClarity Controller 2 (XCC2), which provides advanced control, monitoring, and alerting functions. The XCC2 is based on the AST2600 baseboard management controller (BMC) using a dual-core ARM Cortex A9 service processor.

Topics in this section:

Local management

The SE350 V2 offers a front operator panel with key LED status indicators, as shown in the following figure.

SE350 V2 front operator panel
Figure 11. Front operator panel

The buttons on the front of the server:

  • Power button
  • Identification button - turns on the LED housed within the button as well as passing the signal to the XCC for display remotely in XClarity Administrator
  • NMI reset pinhole - sends a NMI signal to the processor thereby causing a blue-screen trap of the operating system

The LEDs on the front of the server are as follows:

  • Power LED (green) - indicated activation and power status, as follows:
    • Off - Server does not have power applied
    • Fast flash (4 times per second) - Either server has just had power applied and is not ready to be powered on yet, or the server has not been activated yet
    • Slow flash (once per second) - Server is ready to be powered on
    • On solid - Server is powered on
  • Identification LED (blue) - lights when the button is pressed or when the function is activated remotely in XClarity Controller.
  • Security LED - (green) - indicates system security status.
    • Solid on - the server is operating with security enabled
    • Blinking - the server is in lockdown mode. Activate or unlock the system for operation or activation. See activate or unlock system.
    • Off - No security feature is enabled on the server.

The front of the server also houses an information pull-out tab (also known as the network access tag). See Figure 2 for the location. A label on the tab shows the network information (MAC address and other data) to remotely access the XCC service processor.

The SE350 V2 also supports optional connection to local VGA monitor.

Table 17. USB type-C to VGA cable
Part number Feature code Description
4X97A86591 BS4E ThinkEdge 130mm USB-C to VGA Display Cable

System status with XClarity Mobile

The SE350 V2 also supports local systems management using the XClarity Mobile app. The app includes a tethering function where you can connect your Android or iOS device to the server via the micro-USB port on the server.

You will need a mobile device with a supported operating system installed (iOS 12 or later, Android 5.0 or later), plus the USB charging cable that comes with your phone. You will also need the USB type-C to USB type-A cable that ships with the SE350 V2.

The steps to connect the mobile device are as follows:

  1. Connect the mobile device via your USB cable and the supplied USB-to USB type-C cable to the SE350 V2's USB type-C port with the management symbol USB Management symbol
  2. In iOS or Android settings, enable Personal Hotspot or USB Tethering
  3. Launch the Lenovo XClarity Mobile app

Once connected you can see the following information:

  • Server status including error logs (read only, no login required)
  • Server management functions (XClarity login credentials required)

The supported USB cable is listed in the following table.

Table 18. USB type-C to USB type-A cable
Part number Feature code Description
4X97A88620 BS4D ThinkEdge USB-C to USB-A Console Cable

Remote management

The server offers a dedicated RJ45 port at the rear of the server for remote management via the XClarity Controller management processor. The port supports 10/100/1000 Mbps speeds.

Remote server management is provided through industry-standard interfaces:

  • Intelligent Platform Management Interface (IPMI) Version 2.0
  • Simple Network Management Protocol (SNMP) Version 3 (no SET commands; no SNMP v1)
  • Common Information Model (CIM-XML)
  • Representational State Transfer (REST) support
  • Redfish support (DMTF compliant)
  • Web browser - HTML 5-based browser interface (Java and ActiveX not required) using a responsive design (content optimized for device being used - laptop, tablet, phone) with NLS support

The SE350 V2 offers a MicroSD card port on the system board to enable the use of a MicroSD card for additional storage for use with the XCC2 controller. XCC2 can use the storage as a Remote Disc on Card (RDOC) device (up to 32GB of storage). It can also be used to store firmware updates (including N-1 firmware history) for ease of deployment.

Tip: Without a MicroSD card installed, the XCC2 controller will have 100MB of available RDOC storage.

Ordering information for the supported Micro SD card is listed in the following table.

Table 19. MicroSD card
Part number Feature code Description
4X77A77064 BNWP ThinkSystem MicroSD 32GB Class 10 Flash Memory Card

XCC2 Platinum

The XCC2 service processor in the SE350 V2 supports an upgrade to a Platinum level of features. Compared to the XCC functions of ThinkSystem and earlier systems, Platinum adds the same features as Enterprise and Advanced levels in ThinkSystem, plus additional features.

XCC2 Platinum adds the following Enterprise and Advanced functions:

  • Remotely viewing video with graphics resolutions up to 1600x1200 at 75 Hz with up to 23 bits per pixel, regardless of the system state
  • Remotely accessing the server using the keyboard and mouse from a remote client
  • International keyboard mapping support
  • Syslog alerting
  • Redirecting serial console via SSH
  • Component replacement log (Maintenance History log)
  • Access restriction (IP address blocking)
  • Lenovo SED security key management
  • Displaying graphics for real-time and historical power usage data and temperature
  • Boot video capture and crash video capture
  • Virtual console collaboration - Ability for up to 6 remote users to be log into the remote session simultaneously
  • Remote console Java client
  • Mapping the ISO and image files located on the local client as virtual drives for use by the server
  • Mounting the remote ISO and image files via HTTPS, SFTP, CIFS, and NFS
  • Power capping
  • System utilization data and graphic view
  • Single sign on with Lenovo XClarity Administrator
  • Update firmware from a repository
  • License for XClarity Energy Manager

XCC2 Platinum also adds the following features that are new to XCC2:

  • System Guard - Monitor hardware inventory for unexpected component changes, and simply log the event or prevent booting
  • Enterprise Strict Security mode - Enforces CNSA 1.0 level security
  • Neighbor Group - Enables administrators to manage and synchronize configurations and firmware level across multiple servers

Ordering information is listed in the following table. XCC2 Platinum is a software license upgrade - no additional hardware is required.

Table 20. XCC2 Platinum license upgrade
Part number Feature code Description
CTO only BRPJ XCC Platinum

With XCC Platinum, for CTO orders, you can request that System Guard be enabled in the factory and the first configuration snapshot be recorded. To add this to an order, select feature code listed in the following table. The selection is made in the Security tab of the DCSC configurator.

Table 21. Enable System Guard in the factory (CTO orders)
Feature code Description
BUT2 Install System Guard

For more information about System Guard, see https://pubs.lenovo.com/xcc2/NN1ia_c_systemguard

Lenovo XClarity Provisioning Manager

Lenovo XClarity Provisioning Manager (LXPM) is a UEFI-based application embedded in ThinkSystem servers and accessible via the F1 key during system boot.

LXPM provides the following functions:

  • Graphical UEFI Setup
  • System inventory information and VPD update
  • System firmware updates (UEFI and XCC)
  • RAID setup wizard
  • OS installation wizard (including unattended OS installation)
  • Diagnostics functions

Lenovo XClarity Administrator

Lenovo XClarity Administrator is a centralized resource management solution designed to reduce complexity, speed response, and enhance the availability of Lenovo systems and solutions. It provides agent-free hardware management for ThinkSystem servers, in addition to ThinkServer, System x, and Flex System servers. The administration dashboard is based on HTML 5 and allows fast location of resources so tasks can be run quickly.

Because Lenovo XClarity Administrator does not require any agent software to be installed on the managed endpoints, there are no CPU cycles spent on agent execution, and no memory is used, which means that up to 1GB of RAM and 1 - 2% CPU usage is saved, compared to a typical managed system where an agent is required.

Lenovo XClarity Administrator is an optional software component for the SE350 V2. The software can be downloaded and used at no charge to discover and monitor the SE350 V2 and to manage firmware upgrades.

If software support is required for Lenovo XClarity Administrator, or premium features such as configuration management and operating system deployment are required, Lenovo XClarity Pro software subscription should be ordered. Lenovo XClarity Pro is licensed on a per managed system basis, that is, each managed Lenovo system requires a license.

The following table lists the Lenovo XClarity software license options.

Table 22. Lenovo XClarity Pro ordering information
Part number Feature code Description
00MT201 1339 Lenovo XClarity Pro, per Managed Endpoint w/1 Yr SW S&S
00MT202 1340 Lenovo XClarity Pro, per Managed Endpoint w/3 Yr SW S&S
00MT203 1341 Lenovo XClarity Pro, per Managed Endpoint w/5 Yr SW S&S
7S0X000HWW SAYV Lenovo XClarity Pro, per Managed Endpoint w/6 Yr SW S&S
7S0X000JWW SAYW Lenovo XClarity Pro, per Managed Endpoint w/7 Yr SW S&S

Lenovo XClarity Administrator offers the following standard features that are available at no charge:

  • Auto-discovery and monitoring of Lenovo systems
  • Firmware updates and compliance enforcement
  • External alerts and notifications via SNMP traps, syslog remote logging, and e-mail
  • Secure connections to managed endpoints
  • NIST 800-131A or FIPS 140-2 compliant cryptographic standards between the management solution and managed endpoints
  • Integration into existing higher-level management systems such as cloud automation and orchestration tools through REST APIs, providing extensive external visibility and control over hardware resources
  • An intuitive, easy-to-use GUI
  • Scripting with Windows PowerShell, providing command-line visibility and control over hardware resources

Lenovo XClarity Administrator offers the following premium features that require an optional Pro license:

  • Pattern-based configuration management that allows to define configurations once and apply repeatedly without errors when deploying new servers or redeploying existing servers without disrupting the fabric
  • Bare-metal deployment of operating systems and hypervisors to streamline infrastructure provisioning

For more information, refer to the Lenovo XClarity Administrator Product Guide:
http://lenovopress.com/tips1200

Lenovo XClarity Integrators

Lenovo also offers software plug-in modules, Lenovo XClarity Integrators, to manage physical infrastructure from leading external virtualization management software tools including those from Microsoft and VMware.

These integrators are offered at no charge, however if software support is required, a Lenovo XClarity Pro software subscription license should be ordered.

Lenovo XClarity Integrators offer the following additional features:

  • Ability to discover, manage, and monitor Lenovo server hardware from VMware vCenter or Microsoft System Center
  • Deployment of firmware updates and configuration patterns to Lenovo x86 rack servers and Flex System from the virtualization management tool
  • Non-disruptive server maintenance in clustered environments that reduces workload downtime by dynamically migrating workloads from affected hosts during rolling server updates or reboots
  • Greater service level uptime and assurance in clustered environments during unplanned hardware events by dynamically triggering workload migration from impacted hosts when impending hardware failures are predicted

For more information about all the available Lenovo XClarity Integrators, see the Lenovo XClarity Administrator Product Guide: https://lenovopress.com/tips1200-lenovo-xclarity-administrator

Lenovo XClarity Essentials

Lenovo offers the following XClarity Essentials software tools that can help you set up, use, and maintain the server at no additional cost:

  • Lenovo Essentials OneCLI

    OneCLI is a collection of server management tools that uses a command line interface program to manage firmware, hardware, and operating systems. It provides functions to collect full system health information (including health status), configure system settings, and update system firmware and drivers.

  • Lenovo Essentials UpdateXpress

    The UpdateXpress tool is a standalone GUI application for firmware and device driver updates that enables you to maintain your server firmware and device drivers up-to-date and help you avoid unnecessary server outages. The tool acquires and deploys individual updates and UpdateXpress System Packs (UXSPs) which are integration-tested bundles.

  • Lenovo Essentials Bootable Media Creator

    The Bootable Media Creator (BOMC) tool is used to create bootable media for offline firmware update.

For more information and downloads, visit the Lenovo XClarity Essentials web page:
http://support.lenovo.com/us/en/documents/LNVO-center

Lenovo XClarity Energy Manager

Lenovo XClarity Energy Manager (LXEM) is a power and temperature management solution for data centers. It is an agent-free, web-based console that enables you to monitor and manage power consumption and temperature in your data center through the management console. It enables server density and data center capacity to be increased through the use of power capping.

LXEM is a licensed product. A single-node LXEM license is included with the XClarity Controller Enterprise upgrade as described in the Remote Management section. If your server does not have the XCC Enterprise upgrade, Energy Manager licenses can be ordered as shown in the following table.

Table 23. Lenovo XClarity Energy Manager
Part number Description
4L40E51621 Lenovo XClarity Energy Manager Node License (1 license needed per server)

For more information about XClarity Energy Manager, see the following resources:

Lenovo Capacity Planner

Lenovo Capacity Planner is a power consumption evaluation tool that enhances data center planning by enabling IT administrators and pre-sales professionals to understand various power characteristics of racks, servers, and other devices. Capacity Planner can dynamically calculate the power consumption, current, British Thermal Unit (BTU), and volt-ampere (VA) rating at the rack level, improving the planning efficiency for large scale deployments.

For more information, refer to the Capacity Planner web page:
http://datacentersupport.lenovo.com/us/en/solutions/lnvo-lcp

Security

The SE350 V2 offers a number of security features, both electronic and physical.

Security features of the SE350 V2
Figure 12. Security features of the SE350 V2

Physical security features:

  • Support for a Kensington lock and cable

    The server has a slot on the side of the server which a customer-supplied Kensington lock and cable can be attached to, to help prevent theft of the server.

  • Intrusion arm/disarm feature

    The Kensington cable slot can also double as an electronic switch to disarm the intrusion switch detection, so that authorized servicing of the hardware can be performed without triggering the security actions. Available as the Anti-Tampering Keylock Kit, CTO only. The kit includes a Kensington lock (without cable) that is attached to the outside of the server.

    Note: This intrusion arm/disarm feature is not supported with the 1U or 2U rack enclosure mounting options, due to physical restrictions with the Kensington lock.

  • Front bezel with key lock

    Optional component that mounts on the front of the server that restricts access to networking connectors on the front of the server. See "mounting options" section for more information.

Electronic security features include:

  • Self-encrypting (SED) on M.2 and 2.5" SSD drives that ensure data is secured when the drives are powered off
  • Administrator password and a power-on password in UEFI
  • Onboard Trusted Platform Module (TPM) supporting TPM 2.0 enables advanced cryptographic functionality in the operating system and applications.
  • For China users, the server has an internal TCM port that supports a Nationz TPM 2.0 module. Available CTO only.

The server is NIST SP 800-147B compliant.

Ordering information for the security components is listed in the following table.

Table 24. Security components
Part number Feature code Description
4XF7A88717 BS4J

ThinkEdge SE350 V2 Anti-Tampering Keylock Kit

  • Internal lock mechanism with electronic switch
  • Cable and routing tray
  • Kensington lock with key
CTO only B8LE ThinkSystem NationZ TPM 2.0 for PRC

System Lockdown Mode

System Lockdown Mode is an optional security feature of the SE350 V2 that ensures that the system is only used by its intended recipient and that all data and applications remains secure.

System Lockdown Mode is an optional feature that can be remotely managed in two ways:

  • ThinkShield Key Vault Portal Managed. This provides a centralised remote management approach, allowing the administrator to remotely managed multiple systems and to register ownership of systems to their company, which reduces the system’s value is stolen.
  • XClarity Controller Managed. This provides remote management level control to an individual system using XCC web interface, OneCLI or Redfish.

To select ThinkShield Key Vault Portal Managed in factory orders, select feature BYBR, as listed in the following table. The default in DCSC is to select XClarity Controller Managed, feature BYBQ.

Table 25. Feature codes to activate System Lockdown mode
Feature code Description Purpose
BYBR ThinkShield Key Vault Portal Managed System Lockdown Mode is enabled in the factory (Activation required on delivery). The server remains secured and in System Lockdown Mode until registered and activated with the ThinkEdge Key Vault Portal. Unauthorized tampering of the server will result in the server being locked down and the data secured, and will remain in this state until reauthenticated with the Key Vault Portal.
BYBQ XClarity Controller Managed Default choice in DCSC. System Lockdown Mode is not enabled in the factory. Configures the server security to be managed by the XCC2 management processor. Server will boot at first power on and, by default, will not be locked down on any tamper event. You can configure tamper detection in the XCC2 interface if desired. The server can be converted to be managed ThinkShield Key Vault Portal at a later stage if desired (one-way conversion).

If System Lockdown is enabled in the factory, the system will be delivered in system lockdown mode and will require activation before operation. There are three ways the server can be activated:

  • Using a mobile device (iOS or Android) connect to the server to the USB management port on the front of the server and running the ThinkShield Edge Mobile Management app.
  • Connecting the system to the Internet via the XCC management port on the front of the server and accessing the ThinkShield Key Vault Portal from a web browser on another system.
  • In a disconnected mode, where neither a mobile device or an internet connection to the SE350 V2 are available.

For more information, see ThinkEdge Security, available from:
https://lenovopress.lenovo.com/lp1725-thinkedge-security

Converting from XCC Managed to Portal Managed: It is possible to convert a system from XCC Managed security to ThinkShield Key Vault Portal Managed via the XCC management interface, however the reverse is not possible. Once a server is in ThinkShield Key Vault Portal Managed mode, it cannot be converted back to XClarity Controller Managed.

The SE350 V2 offers a Security LED that indicates the status of the server:

  • LED on: Security is enabled; System is operational.
  • LED blinking: Security is enabled and the server is in lockdown, either due to being delivered from the factory in lockdown mode or has entered lockdown as a result of a tamper event. System must be activated or reactivated before becoming operational.
  • LED off: Security is disabled; System is operational.

SED encryption in factory orders

The SE350 V2 also optionally supports enabling SED drive encryption in the factory using feature BYBS as listed in the following table. This feature enables SED on the selected drives and sets and SED Authentication Key (SED AK).

Tip: SED encryption is a function that is independent of System Lockdown Control.

Table 26. System Lockdown
Feature code Description Purpose
BYBS SED Enabled Enables SED drive encryption on all factory installed drives and sets an SED Authentication Key (AK).

System Guard

The System Guard feature takes a snapshot of the hardware component inventory as trusted reference, then monitors for any deviation from the reference snapshot. 

When deviation occurs, it can report an event to the user, optionally, can also prevent the server from booting into the OS and prompt the user for response.

  • System Guard is only enabled with XCC2 on V3 code 
  • Server supports this feature (BUT2) when XCC Platinum enabled only.
  • The System Guard feature is disabled by default

System Guard is a feature of XCC Platinum. Sytem Guard (BUT2) should only be selectable if XCC Platinum (BRPJ) is selected.

Table 27. XCC platinum and System Guard details
Feature code Description
BRPJ XCC Platinum
BUT2 Enable System Guard

Platform Firmware Resiliency - Lenovo ThinkShield

Lenovo's ThinkShield Security is a transparent and comprehensive approach to security that extends to all dimensions of our data center products: from development, to supply chain, and through the entire product lifecycle.

The includes Platform Firmware Resiliency (PFR) hardware Root of Trust (RoT) which enables the system to be NIST SP800-193 compliant. This offering further enhances key platform subsystem protections against unauthorized firmware updates and corruption, to restore firmware to an integral state, and to closely monitor firmware for possible compromise from cyber-attacks.

PFR operates upon the following server components:

  • UEFI image – the low-level server firmware that connects the operating system to the server hardware
  • XCC image – the management “engine” software that controls and reports on the server status separate from the server operating system
  • FPGA image – the code that runs the server’s lowest level hardware controller on the motherboard

The Lenovo Platform Root of Trust Hardware performs the following three main functions:

  • Detection – Measures the firmware and updates for authenticity
  • Recovery – Recovers a corrupted image to a known-safe image
  • Protection – Monitors the system to ensure the known-good firmware is not maliciously written

These enhanced protection capabilities are implemented using a dedicated, discrete security processor whose implementation has been rigorously validated by leading third-party security firms. Security evaluation results and design details are available for customer review – providing unprecedented transparency and assurance.

The SE350 V2 includes support for Secure Boot, a UEFI firmware security feature developed by the UEFI Consortium that ensures only immutable and signed software are loaded during the boot time. The use of Secure Boot helps prevent malicious code from being loaded and helps prevent attacks, such as the installation of rootkits. Lenovo offers the capability to enable secure boot in the factory, to ensure end-to-end protection. Alternatively, Secure Boot can be left disabled in the factory, allowing the customer to enable it themselves at a later point, if desired.

The following table lists the relevant feature code(s).

Table 28. Secure Boot options
Part number Feature code Description Purpose
CTO only AUK7 TPM 2.0 and Secure Boot Configure the system in the factory with Secure Boot enabled.
CTO only B0MK Enable TPM 2.0 Configure the system without Secure Boot enabled. Customers can enable Secure Boot later if desired.

Tip: If Secure Boot is not enabled in the factory, it can be enabled later by the customer. However once Secure Boot is enabled, it cannot be disabled.

Intel Transparent Supply Chain

Add a layer of protection in your data center and have peace of mind that the server hardware you bring into it is safe authentic and with documented, testable, and provable origin.

Lenovo has one of the world’s best supply chains, as ranked by Gartner Group, backed by extensive and mature supply chain security programs that exceed industry norms and US Government standards. Now we are the first Tier 1 manufacturer to offer Intel® Transparent Supply Chain in partnership with Intel, offering you an unprecedented degree of supply chain transparency and assurance.

To enable Intel Transparent Supply Chain for the Intel-based servers in your order, add the following feature code in the DCSC configurator, under the Security tab.

Table 29. Intel Transparent Supply Chain ordering information
Feature code Description
BB0P Intel Transparent Supply Chain

For more information on this offering, see the paper Introduction to Intel Transparent Supply Chain on Lenovo ThinkSystem Servers, available from https://lenovopress.com/lp1434-introduction-to-intel-transparent-supply-chain-on-thinksystem-servers.

Mounting options

The SE350 V2 is designed to be used in a variety of locations --  wall, ceiling, DIN-rail, table top -- as well as in a rack mount.

In this section:

Mounting components

Many of the mounting options share the same components.

Node sleeve

The node sleeve, shown below, holds the SE350 V2 server when mounted on the wall or connected to DIN rail. The server is then slid into the node sleeve and secured with additional thumbscrews.

Node sleeve for SE350 V2

Figure 13. Node sleeve image

Table 30. Node Sleeve ordering information
Part number Feature code Description Quantity
required
4M17A37607 B6EZ ThinkEdge Node Sleeve (VESA mount)  1 per server

Desktop mount

Desktop mounting has the server oriented horizontally with self-adhesive rubber pads mounted to its underside.

SE350 V2 with Rubber Feet option
Figure 14. SE350 V2 with Rubber Feet option

Table 31. Desktop mount components
Part number Feature code Description Quantity
required
4M17A37610 B6Q3 ThinkEdge Rubber Feet (contains 4 rubber pads)
1

Wall or DIN mount

When wall, ceiling or DIN mounted, the server must be installed onto a sleeve first. For DIN mount, the optional DIN mount kit is required. Server also supports security bezel placement on the front of the node sleeve to help prevent physical access to the front components.

SE350 V2 supports two types of security bezels for each of the two I/O module boards. Bezels include:

  • A lock-and-key mechanism for security also support dust filter with optional (4XF7A86284).
  • Filter cover the backplane area for SSD and the network area to reduce the dust that can enter the server through the front air holes.
  • Security bezel can prevent LAN cable plug or unplug after installed on node sleeve.

Tip: 300W external adapter not supported in Wall / DIN mounting

Table 32. Wall or DIN mount
Part number Feature code Description Quantity
required
Wall mount mode
4M17A37607 B6EZ ThinkEdge Node Sleeve 1 per server
DIN Rail mount mode
4M17A37607 B6EZ ThinkEdge Node Sleeve 1 per server
4M17A37285 B87S ThinkEdge DIN Mount Kit (Extreme Shock & Vibe) Optional, for DIN rail only, 1 per server
Security Bezel
4B37A86282 BS4F ThinkEdge SE350 V2 Security Bezel for 10/25GbE I/O Module Optional, 1 per server
4B37A86283 BS4G  ThinkEdge SE350 V2 Security Bezel for 1GbE I/O Module Optional, 1 per server
4XF7A86284 BS4H ThinkEdge SE350 V2 Security Bezel Dust Filter Optional, 1 per server

The DIN Rail Kit contains two brackets, as shown in the following figure.

DIN Rail Kit
Figure 15. DIN Rail Kit

Security bezel

The security bezel is an optional component that mounts on the front of the node sleeve to help prevent physical access to the front components of the server. The bezel includes a lock-and-key mechanism for security. The bezel covers the front slots area and the network area to reduce the dust that can enter the server through the front air holes. For part number and feature code detail refer to Wall or DIN mount table above.

Tip: The use of the security bezel requires a node sleeve.

Security bezel for SE350 V2

Figure 16. Security Bezel

1U rack installation

Two SE350 V2 servers can be mounted in a 1U space, in a rack server. The components are mounted in the Lenovo ThinkEdge SE350 V2 1U2N Enclosure.
ThinkEdge SE350 V2 1U2N Enclosure have two different enclosure to support three type of power input path. Make sure enclosure and server selection leverage the same power input path for installation.

Notes:

  • Lenovo ThinkEdge SE350 V2 1U2N Enclosure is available in DCSC using CTO base model 7DBKCTO1WW

The following figure shows two SE350 V2 servers installed in the 1U2N Enclosure.

Lenovo ThinkEdge SE350 V2 1U2N Enclosure
Figure 17. Lenovo ThinkEdge SE350 V2 1U2N Enclosure with external adapter

The following figure shows the components used in the 1U rack installation.

Lenovo ThinkEdge SE350 V2 1U2N Enclosure components
Figure 18. Lenovo ThinkEdge SE350 V2 1U2N Enclosure with external adapter components

Tip: The ThinkSystem Friction 2-Post Screw-in Rail Kit (B6H2) with external 300W AC power adapters is not supported in a 2-post rack.

The following figure shows the 1U short rack.

The 1U short rack

Figure 19. Lenovo ThinkEdge SE350 V2 1U2N Enclosure with Pure AC Input and DC direct

The following table lists the components used in the 1U rack installation.

Tip: The top cover of the SE350 V2 is removed before installing the server in the enclosure.

Table 33. Components for the 1U2N Enclosure
Part number Feature code Description Quantity
required
Toolless Slide Rail Kit and CMA
CTO/model only* 7DBK AVAX CMA (1U) 1 per Enclosure
4M17A11683 7DBK AVAL 1U and 2U Slide Rail 1 per Enclosure
4XF7A83645 7DBK BS30 ThinkSystem Enclosure Universal Short Rack Rail Kit 1 per Enclosure
4M17A37105 7DBK B6H2 ThinkSystem Friction 2-Post Screw-in Rail Kit 1 per Enclosure
1U2N Enclosure components
CTO/model only* 7DBK BSMC ThinkEdge SE350 V2 1U2N Enclosure (DC or External PSU) 1 per Enclosure
CTO/model only* 7DBK BVGY ThinkEdge SE350 V2 1U2N Enclosure (AC) 1 per Enclosure
CTO/model only* 7DBK B6EE ThinkEdge Enclosure AC Adapter Support Bracket 1 per Enclosure
4XF7A94042 7DAM/7DAM BVE5 ThinkEdge SE350 V2/SE360 V2 Dust Cover Kit for I/O Ports 1 per Enclosure
4XF7A94043 7DBK BSML ThinkEdge SE350 V2 Enclosure Shipping Bracket 1 per Enclosure
4XF7A86286 7DBK BSMD ThinkEdge SE350 V2 Enclosure - Rack Dust Filter 1 for each server

* Available via configure-to-order (CTO)

The following figure shows the components included in the Front Shipping Bracket.

ThinkSystem Enclosure Front Shipping Bracket
Figure 20. 1U2N Enclosure Front Shipping Bracket

The following table summarizes the specifications of the two available rail kits

Table 34. Specifications of 1U and 2U Slide Rail
Feature Slide Rail Kit
Part number 4M17A11683
CMA Optional, CTO/model only* (7DBK AVAX)
Rail length 807 mm (31.8 in.)
Rail type Full-out slide (ball bearing)
Slide travel 810 mm (31.9 in.)
Tool-less installation Yes
In-rack server maintenance Yes
1U PDU support Yes
0U PDU support Yes
Rack type IBM and Lenovo 4-post, IEC standard-compliant
Mounting holes Square or round
Mounting flange thickness 2 mm (0.08 in.) – 3.3 mm (0.13 in.)
Max distance between front
and rear mounting flanges
864 mm (34.0 in.)

* Available via configure-to-order (CTO)

Short-depth 2U rack installation

Two SE350 V2 servers and the four companion AC Adapter power supplies can also be mounted in a short-depth rack or a 2-post rack. In such a configuration, the servers occupy 2U of rack space, the two servers in 1U and the AC Adapters mounted in the 1U space above. The components are mounted in the Lenovo ThinkEdge SE350 V2 2U2N Enclosure, machine type 7DBK.

Note: 2U2N enclosure supports SE350 V2 server and external 300W PSU adapter only.

Notes:

  • Lenovo ThinkEdge SE350 V2 2U2N Enclosure is available in DCSC using CTO base model 7DBKCTO2WW

The following figure shows two SE350 V2 servers installed in the Lenovo ThinkEdge SE350 V2 2U2N Enclosure.

2U2N Enclosure
Figure 21. Lenovo ThinkEdge SE350 V2 2U2N Enclosure components (rail in open position)

The following table lists the components used in the 1U rack installation.

Tip: The top cover of the SE350 V2 is removed before installing the server in the enclosure.

Table 35. Components for the 2U2N Enclosure
Part number Feature code Description Quantity
required
Rail kit selections (choose 1)
4M17A37105 7DBK B6H2 ThinkSystem Friction 2-Post Screw-in Rail Kit 1 per enclosure
4XF7A83645 7DBK BS30 ThinkSystem Enclosure Universal Short Rack Rail Kit 1 per enclosure
2U2N Enclosure components
CTO/model only* 7DBK BY35 ThinkEdge SE350 V2 2U2N Enclosure (External PSU) 1 per Enclosure
CTO/model only* 7DBK B6EE ThinkSystem Enclosure AC Adapter Support Bracket 1 per Enclosure
4XF7A94042 7DAM/7DAM BVE5 ThinkEdge SE350 V2/SE360 V2 Dust Cover Kit for I/O Ports 1 per Enclosure
4XF7A94043 7DBK BSML ThinkEdge SE350 V2 Enclosure Shipping Bracket 1 per Enclosure
4XF7A86286 7DBK BSMD ThinkEdge SE350 V2 Enclosure - Rack Dust Filter 1 for each server

* Available via configure-to-order (CTO)

The following figure shows the components included in the Front Shipping Bracket.

ThinkSystem Enclosure Front Shipping Bracket
Figure 22. ThinkEdge SE350 V2 Enclosure Shipping Bracket

The following table summarizes the specifications of the two available rail kits

Table 36. Specifications of rail kits for short-depth installations
Feature Short Rack Rail Kit 2-Post Screw-in Rail Kit
Part number 4XF7A83645 4M17A37105
CMA None None
Rail length 484 mm (19.1 in.) 484 mm (19.1 in.)
Rail type Half-out slide (friction) Half-out slide (friction)
Slide travel 270 mm (10.6 in.) 270 mm (10.6 in.)
Tool-less installation Yes No
In-rack server maintenance No No
1U PDU support Yes Yes
0U PDU support Yes Not applicable
Rack type 14-inch to 24-inch depth 2-post, EIA standard-compliant (3-inch to 8-inch)
Mounting holes Square, round, or threaded Square, round, or threaded
Mounting flange thickness 2 mm (0.08 in.) – 3.3 mm (0.13 in.) 2 mm (0.08 in.) – 3.3 mm (0.13 in.)
Max distance between front
and rear mounting flanges
609 mm (24 in.) Not applicable

For additional information on rack mount installation, see the Configuration Installation Guide:
https://pubs.lenovo.com/se350-v2/install_a_node_to_rack

Mounting options and power

The following table list supported mounting options and their corresponding supported power type.

Table 37. Mounting options and supported power type
Power type / PSU Desktop DIN rail (wall/ceiling) Rack 1U2N Rack  2U2N
AC & 300W external Yes  No Yes Yes
DC only  Yes Yes Yes  No
AC only Yes Yes Yes No

Operating system support

The SE350 V2 supports the following operating systems:

  • Microsoft Windows Server 2019
  • Microsoft Windows Server 2022
  • Red Hat Enterprise Linux 8.6
  • Red Hat Enterprise Linux 8.8
  • Red Hat Enterprise Linux 9.0
  • Red Hat Enterprise Linux 9.2
  • SUSE Linux Enterprise Server 15 SP4
  • SUSE Linux Enterprise Server 15 SP5
  • SUSE Linux Enterprise Server 15 Xen SP4
  • SUSE Linux Enterprise Server 15 Xen SP5
  • Ubuntu 20.04 LTS 64-bit
  • Ubuntu 22.04 LTS 64-bit
  • VMware ESXi 7.0 U3
  • VMware ESXi 8.0 U1
  • VMware ESXi 8.0 U2

For a complete list of supported, certified and tested operating systems, plus additional details and links to relevant web sites, see the Operating System Interoperability Guide: https://lenovopress.lenovo.com/osig#support=all

For configure-to-order configurations, the server can be preloaded with VMware ESXi on M.2 cards installed in an M.2 Boot Adapter. Ordering information is listed in the following table.

Table 38. VMware ESXi preload
Part number Feature code Description
CTO only BMEY VMware ESXi 7.0 U3 (Factory Installed)
CTO only BQ8S VMware ESXi 8.0 U1 (Factory Installed)
CTO only BYC7 VMware ESXi 8.0 U2 (Factory Installed)

Hyperconverged infrastructure support

Lenovo ThinkEdge systems can be used in hyperconverged solutions either as part of a Lenovo configured and optimized Lenovo ThinkAgile solution, or as a user-configured system. 

Refer to the following links for full details.

VMware vSAN

SE350 V2 supports vSAN OSA. For more information refer to this page:
vSAN Original Storage Architecture (OSA)

Microsoft Azure Stack HCI

SE350 V2 is listed in Microsoft Azure Stack HCI catalog. For more information refer to this page:
https://azurestackhcisolutions.azure.microsoft.com/#/catalog/details/d047fc7e-5df1-43d1-97f5-907f0bc65004

Sunlight

SE350 V2 is supported by Sunlight HyperConverged Edge. For more information refer to this page:
https://sunlight.io/products/thinkedgethinksystem

Physical and electrical specifications

Dimensions and weight of the SE350 V2 server:  

  • Height 41.7 mm (1.64 in.)
  • Width: 209 mm (8.2 in.)
  • Depth: 384 mm (15.12 in.)
  • Maximum weight: 3.75 kg (8.3 lb)

Dimensions and weight of the 1U2N Enclosure, with external power adapter (4x AC adapter bracket):

  • Height: 43 mm (1.7 in.)
  • Width: 439.2 mm (17.3 in.) (from EIA bracket to EIA bracket)
  • Depth: 773.1 mm (30.44 in.)
  • Maximum (with 2 nodes and 4 external power adapters): 16.88 kg (37.2 lbs)

Dimensions and weight of the 1U2N Enclosure, with internal power supply:

  • Height: 43 mm (1.7 in.)
  • Width: 439.2 mm (17.3 in.) (from EIA bracket to EIA bracket)
  • Depth: 476.1 mm (18.7 in.)
  • Maximum (with 2 nodes and internal power supplies):
    • DC power input: 9.85 kg (21.67 lbs)
    • AC power input: 10.03 kg (22.11 lbs)

Dimensions and weight of the 2U2N Enclosure (with AC adapter bracket):

  • Height: 86.9 mm (3.4 in.)
  • Width: 439.2 mm (17.3 in.) (from EIA bracket to EIA bracket)
  • Depth: 476.1 mm (18.74 in.)
  • Maximum (with 2 nodes and 4 external power adapters): 16.92 kg (37.30 lbs)

The shipping dimensions (cardboard packaging) of the SE350 V2 are as follows:

  • Width: 338 mm (13.3 inches)
  • Height: 179 mm (7.0 inches)
  • Depth: 569 mm (22.4 inches)

The shipping dimensions (cardboard packaging) of the SE350 V2 1U Enclosure are as follows:

  • Width: 587 mm (23.1 inches)
  • Height: 225 mm (8.9 inches)
  • Depth: 998 mm (39.3 inches)

Electrical specifications:

  • Electrical Input -  20V 300W external adapters
    • 100 to 127 (nominal) V AC, 50 Hz or 60 Hz
    • 200 to 240 (nominal) V AC, 50 Hz or 60 Hz 
  • Models with DC/DC power module board (output 12V):
    • Dual 12-48V variable DC power source input
    • Up to two 300W (230V/115V) external power adapters
  • Supported external power adapters:
    • ThinkEdge 300W 230V/115V External Power Supply

Operating environment

Summary of the environmental specifications of server. Depending on the model, some features might not be available, or some specifications might not apply.

Topics in this section:

Acoustical noise emissions

The server has the following acoustic noise emissions declaration:

  • Sound power level (LWAd):
    • Idling:
      • Minimum: 4.0 bels
      • Typical: 4.0 bels
      • Maximum: 4.0 bels
    • Operating:
      • Minimum: 5.3 bels
      • Typical: 5.8 bels
      • Maximum: 5.8 bels
  • Sound pressure level (LpAm):
    • Idling:
      • Minimum: 26.0 dBA
      • Typical: 26.2 dBA
      • Maximum: 26.2 dBA
    • Operating:
      • Minimum: 39.7 dBA
      • Typical: 44.2 dBA
      • Maximum: 44.2 dBA

Note: 

  • These sound levels were measured in controlled acoustical environments according to procedures specified by ISO 7779 and are reported in accordance with ISO 9296. The operating profile is represented by 80% CPU TDP or 70%/30% storage read/write.

  • The declared acoustic noise levels are based on the following configurations, which may change depending on configurations/conditions.
    • Minimum: 1x 65W CPU, 2x 16GB RDIMMs, 1GbEx4 + 2.5GbE I/O module board, 1x NVMe M.2 boot drive, 2x SATA SSDs, DC PMB, SE350 V2 Desktop mount.
    • Typical: 1x 80W CPU, 4x 64GB RDIMMs, 25/10GbEx4 + 2.5GbE I/O module board, 2x NVMe M.2 boot drives, 4x NVMe SSDs, DC PMB, SE350 V2 Desktop mount.
    • Maximum: 1x 100W CPU, 4x 64GB RDIMMs, 25/10GbEx4 + 2.5GbE I/O module board, 2x NVMe M.2 boot drives, 4x NVMe SSDs, DC PMB, SE350 V2 Desktop mount.
  • Government regulations (such as those prescribed by OSHA or European Community Directives) may govern noise level exposure in the workplace and may apply to you and your server installation. The actual sound pressure levels in your installation depend upon a variety of factors, including the number of racks in the installation; the size, materials, and configuration of the room; the noise levels from other equipment; the room ambient temperature, and employee's location in relation to the equipment. Further, compliance with such government regulations depends on a variety of additional factors, including the duration of employees' exposure and whether employees wear hearing protection. Lenovo recommends that you consult with qualified experts in this field to determine whether you are in compliance with the applicable regulations.

Ambient temperature management

Adjust ambient temperature when specific components are installed:

  • Keep the ambient temperature to 45°C or lower when one or more NVMe drives are installed. If the ambient temperature is over 45°C, the server will have performance degradation.
  • Keep the ambient temperature to 40°C or lower when AC adapters are installed.
  • Keep the ambient temperature to 30°C or lower to avoid performance degradation when choosing the rack mount with the SE350 V2 1U2N Enclosure. It is advised that the ambient temperature should be kept under 27°C when AC adapters are installed.

For CTO orders, specify the operational temperature requirement and the shock & vibration requirement, by selecting the feature codes listed in the following table. Selecting the higher temperature and shock/vibration values will ensure the correct heat/vibration tolerant components are selected.

Table 39. Environmental requirements for CTO orders
Feature code Description
Operational temperature selections
BW2H System Operational Temperature 5C to 40C / 41F to 104F
B8ZU System Operational Temperature 0C to 55C / 32F to 131F

Environment

ThinkEdge SE350 V2 complies with ASHRAE Class A4 specifications. System performance may be impacted when operating temperature is outside AHSARE A4 specification or fan failed condition over 30°C ambient temperature. ThinkEdge SE350 V2 is supported in the following environment:

  • Air temperature:
    • Operating
      • ASHRAE Class H1: 5°C to 25°C (41°F to 77°F); the maximum ambient temperature decreases by 1°C for every 500 m (1640 ft) increase in altitude above 900 m (2,953 ft).
      • ASHRAE Class A2: 10°C to 35°C (50°F to 95°F); the maximum ambient temperature decreases by 1°C for every 300 m (984 ft) increase in altitude above 900 m (2,953 ft).
      • ASHRAE Class A3: 5°C to 40°C (41°F to 104°F); the maximum ambient temperature decreases by 1°C for every 175 m (574 ft) increase in altitude above 900 m (2,953 ft).
      • ASHRAE Class A4: 5°C to 45°C (41°F to 113°F); the maximum ambient temperature decreases by 1°C for every 125 m (410 ft) increase in altitude above 900 m (2,953 ft).
      • The ambient temperature can be extended to 0°C to 55°C (32°F to 131°F) with the following restrictions of configuration:
        • No AC adapter installed
        • NVMe drives may have performance degradation
    • Server off: 0°C to 55°C (32°F to 131°F)
    • Shipping/storage: -40°C to 65°C (-40°F to 149°F)
  • Maximum altitude: 3,050 m (10,000 ft)
  • Relative Humidity (non-condensing):
    • Operating: 8% to 90%, maximum dew point : 24°C (75.2°F)
    • Shipment/storage: 8% to 90%, maximum dew point : 27°C (80.6°F)
    • Non-operating (unpacked) storage can pass the following condition: 5% to 95% at 38.7°C (101.7°F) maximum dry-bulb temperature for 48 hrs.
  • Particulate contamination
    • Depending on the specific configuration,SE350 V2 supports a dust filter installed at the front of the enclosure. The dust filter has a Minimum Efficiency Rating Value (MERV) of 5, per ASHRAE 52.2-2017 / 80% Average Arrestance per ASHRAE 52.1-1992.

Note: Airborne particulates and reactive gases acting alone or in combination with other environmental factors such as humidity or temperature might pose a risk to the server. For information about the limits for particulates and gases, see Particulate contamination.

Shock and vibration

The following information is a summary of the shock and vibration specifications of the server. Depending on the model, some features might not be available, or some specifications might not apply.

Table 40. Shock and vibration specifications
Mounting type Shock (when the server is in operation) Shock (when the server is not in operation, such as in shipping) Vibration (when the server is in operation) Vibration (when the server is not in operation, such as in shipping)
Desktop mount (standing alone)

Half-sine wave, 15G 11ms

Trapezoidal wave, 50G 180 inch/sec

5-100 Hz, 0.15 Grms, 30 mins

2-200 Hz, 1.04 Grms, 15 mins

Rack mount (1U2N and 2U2N)

Half-sine wave, 15G 3ms

  • Free-fall drop height: 100mm
  • Equivalent shock: 70 inch/sec, 2-3 ms

5-500 Hz, 0.21 Grms, 15mins

2-200Hz, 0.8 Grms, 15mins

DIN-rail mount Half-sine wave, 15G 11ms Not applicable 5-100 Hz, 0.15 Grms, 30 mins Not applicable
Wall mount
  • All configurations:
    • Half-sine wave, 40G 6ms
    • Half-sine wave, 30G 11ms
  • Configurations with 7mm drives:
    • Half-sine wave, 30G 18ms
Not applicable
  • 1.91 Grms, 10-500 Hz, 30 mins
  • 1.04 Grms, 10-500 Hz, 1 hr
Not applicable
Ceiling mount Not applicable Not applicable
  • 1.91 Grms, 10-500z, 30 mins
  • 1.04 Grms, 10-500z, 1 hr
Not applicable

The following table indicates what environmental conditions (ambient temperature) are supported with SSD drives.

Table 41. Drive support based on environmental selections (ambient temperature)
Part number Description 0°C to 35°C 36°C to 40°C 41°C to 45°C 46°C to 50°C 51°C to 55°C
7mm SATA SSD - Intel S4520
4XB7A17106 ThinkSystem 7mm S4520 240GB Read Intensive SATA 6Gb HS SSD Yes Yes Yes Yes Yes
4XB7A17107 ThinkSystem 7mm S4520 480GB Read Intensive SATA 6Gb HS SSD Yes Yes Yes Yes Yes
4XB7A17108 ThinkSystem 7mm S4520 960GB Read Intensive SATA 6Gb HS SSD Yes Yes Yes Yes Yes
4XB7A78622 ThinkSystem 7mm S4520 1.92TB Read Intensive SATA 6Gb HS SSD Yes Yes Yes Yes Yes
4XB7A78623 ThinkSystem 7mm S4520 3.84TB Read Intensive SATA 6Gb HS SSD Yes Yes Yes Yes Yes
4XB7A78624 ThinkSystem 7mm S4520 7.68TB Read Intensive SATA 6Gb HS SSD Yes Yes Yes Yes Yes
7mm SATA SSD - Micron 5400
4XB7A82264 ThinkSystem 7mm 5400 PRO 240GB Read Intensive SATA 6Gb HS SSD Yes Yes Yes Yes Yes
4XB7A82265 ThinkSystem 7mm 5400 PRO 480GB Read Intensive SATA 6Gb HS SSD Yes Yes Yes Yes Yes
4XB7A82266 ThinkSystem 7mm 5400 PRO 960GB Read Intensive SATA 6Gb HS SSD Yes Yes Yes Yes Yes
4XB7A82267 ThinkSystem 7mm 5400 PRO 1.92TB Read Intensive SATA 6Gb HS SSD Yes Yes Yes Yes Yes
4XB7A82268 ThinkSystem 7mm 5400 PRO 3.84TB Read Intensive SATA 6Gb HS SSD Yes Yes Yes Yes Yes
4XB7A82269 ThinkSystem 7mm 5400 PRO 7.68TB Read Intensive SATA 6Gb HS SSD Yes Yes Yes Yes Yes
7mm NVMe SSD - Micron 7450
4XB7A82853 ThinkSystem 7mm U.3 7450 PRO 960GB Read Intensive NVMe PCIe 4.0 x4 HS SSD Yes Yes Yes Yes Yes
4XB7A82855 ThinkSystem 7mm U.3 7450 PRO 1.92TB Read Intensive NVMe PCIe 4.0 x4 HS SSD Yes Yes Yes Yes Yes
4XB7A82856 ThinkSystem 7mm U.3 7450 PRO 3.84TB Read Intensive NVMe PCIe 4.0 x4 HS SSD Yes Yes Yes Yes Yes
4XB7A82851 ThinkSystem 7mm U.3 7450 MAX 800GB Mixed Use NVMe PCIe 4.0 x4 HS SSD Yes Yes Yes Yes Yes
15mm NVMe SSD - Micron 7450
4XB7A79647 ThinkSystem 2.5" U.3 7450 PRO 1.92TB Read Intensive NVMe PCIe 4.0 x4 HS SSD Yes Yes Yes Yes† Yes†
4XB7A79648 ThinkSystem 2.5" U.3 7450 PRO 3.84TB Read Intensive NVMe PCIe 4.0 x4 HS SSD Yes Yes Yes Yes† Yes†
4XB7A79649 ThinkSystem 2.5" U.3 7450 PRO 7.68TB Read Intensive NVMe PCIe 4.0 x4 HS SSD Yes Yes Yes Yes† Yes†
4XB7A13967 ThinkSystem 2.5” U.3 7450 MAX 1.6TB Mixed Use NVMe PCIe 4.0 x4 HS SSD Yes Yes Yes Yes† Yes†
4XB7A13970 ThinkSystem 2.5” U.3 7450 MAX 3.2TB Mixed Use NVMe PCIe 4.0 x4 HS SSD Yes Yes Yes Yes† Yes†
15mm NVMe SSD - Intel P5520/P5620
4XB7A17129 ThinkSystem 2.5” U.2 P5620 1.6TB Mixed Use Mainstream NVMe PCIe 4.0 x4 HS SSD Yes Yes Yes Yes† Yes†
4XB7A17130 ThinkSystem 2.5” U.2 P5620 3.2TB Mixed Use Mainstream NVMe PCIe 4.0 x4 HS SSD Yes Yes Yes Yes† Yes†
4XB7A17160 ThinkSystem 2.5” U.2 P5800X 1.6TB Write Intensive NVMe PCIe 4.0 x4 HS SSD Yes Yes Yes Yes† Yes†
4XB7A13941 ThinkSystem 2.5” U.2 P5520 1.92TB Read Intensive NVMe PCIe 4.0 x4 HS SSD Yes Yes Yes Yes† Yes†
4XB7A13942 ThinkSystem 2.5” U.2 P5520 3.84TB Read Intensive NVMe PCIe 4.0 x4 HS SSD Yes Yes Yes Yes† Yes†
4XB7A13943 ThinkSystem 2.5” U.2 P5520 7.68TB Read Intensive NVMe PCIe 4.0 x4 HS SSD Yes Yes Yes Yes† Yes†
M.2 NVMe SSD - Micron 7450
4XB7A82674 ThinkSystem M.2 7450 PRO 960GB Read Intensive NVMe PCIe 4.0 x4 NHS SSD (with Heatsink) Yes Yes Yes Yes Yes
4XB7A83139 ThinkSystem M.2 7450 PRO 480GB Read Intensive NVMe PCIe 4.0 x4 NHS SSD (with Heatsink) Yes Yes Yes Yes Yes

† Performance might slightly decrease with this temperature region

Particulate contamination

Depending on the specific configuration,SE350 V2 supports a dust filter installed at the front of the enclosure. The dust filter has a Minimum Efficiency Rating Value (MERV) of 5, per ASHRAE 52.2-2017 / 80% Average Arrestance per ASHRAE 52.1-1992.

Attention: Airborne particulates (including metal flakes or particles) and reactive gases acting alone or in combination with other environmental factors such as humidity or temperature might pose a risk to the device that is described in this document.

Risks that are posed by the presence of excessive particulate levels or concentrations of harmful gases include damage that might cause the device to malfunction or cease functioning altogether. This specification sets forth limits for particulates and gases that are intended to avoid such damage. The limits must not be viewed or used as definitive limits, because numerous other factors, such as temperature or moisture content of the air, can influence the impact of particulates or environmental corrosives and gaseous contaminant transfer. In the absence of specific limits that are set forth in this document, you must implement practices that maintain particulate and gas levels that are consistent with the protection of human health and safety. If Lenovo determines that the levels of particulates or gases in your environment have caused damage to the device, Lenovo may condition provision of repair or replacement of devices or parts on implementation of appropriate remedial measures to mitigate such environmental contamination. Implementation of such remedial measures is a customer responsibility.

Table 42.  Limits for particulates and gases.
Contaminant  Limits
Reactive gases

Severity level G1 as per ANSI/ISA 71.04-19851:

  • The copper reactivity level shall be less than 200 Angstroms per month (Å/month ≈ 0.0035 μg/cm2-hour weight gain).2
  • The silver reactivity level shall be less than 200 Angstroms per month (Å/month ≈ 0.0035 μg/cm2-hour weight gain).3
  • The reactive monitoring of gaseous corrosivity must be conducted approximately 5 cm (2 in.) in front of the rack on the air inlet side at one-quarter and three-quarter frame height off the floor or where the air velocity is much higher.

Airborne particulates

Data centers must meet the cleanliness level of ISO 14644-1 class 8.

For data centers without airside economizer, the ISO 14644-1 class 8 cleanliness might be met by choosing one of the following filtration methods:

  • The room air might be continuously filtered with MERV 8 filters.
  • Air entering a data center might be filtered with MERV 11 or preferably MERV 13 filters.

For data centers with airside economizers, the choice of filters to achieve ISO class 8 cleanliness depends on the specific conditions present at that data center.

  • The deliquescent relative humidity of the particulate contamination should be more than 60% RH.4
  • Data centers must be free of zinc whiskers.5

Notes:

1ANSI/ISA-71.04-1985.Environmental conditions for process measurement and control systems: Airborne contaminants. Instrument Society of America, Research Triangle Park, North Carolina, U.S.A.

2The derivation of the equivalence between the rate of copper corrosion growth in the thickness of the corrosion product in Å/month and the rate of weight gain assumes that Cu2S and Cu2O grow in equal proportions

.3The derivation of the equivalence between the rate of silver corrosion growth in the thickness of the corrosion product in Å/month and the rate of weight gain assumes that Ag2S is the only corrosion product.

4The deliquescent relative humidity of particulate contamination is the relative humidity at which the dust absorbs enough water to become wet and promote ionic conduction.

5Surface debris is randomly collected from 10 areas of the data center on a 1.5 cm diameter disk of sticky electrically conductive tape on a metal stub. If examination of the sticky tape in a scanning electron microscope reveals no zinc whiskers, the data center is considered free of zinc whiskers.

Table 43. Environmental requirements for CTO orders
Feature code Description
Operational temperature selections
B8ZU System Operational Temperature 0C to 55C / 32F to 131F

Warranty and Support

The ThinkEdge SE350 V2 has 3-year warranty based on the machine type of the system:

  • 7DA9 - 3 year warranty

ThinkEdge SE350 V2 1U2N Enclosure Lenovo and ThinkEdge SE350 V2 2U2N Enclosure have the following warranty:

  • 7DBK - 3 year warranty

The standard warranty terms are customer-replaceable unit (CRU) and onsite (for field-replaceable units FRUs only) with standard call center support during normal business hours and 9x5 Next Business Day Parts Delivered.

Lenovo’s additional support services provide a sophisticated, unified support structure for your data center, with an experience consistently ranked number one in customer satisfaction worldwide. Available offerings include:

  • Premier Support

    Premier Support provides a Lenovo-owned customer experience and delivers direct access to technicians skilled in hardware, software, and advanced troubleshooting, in addition to the following:

    • Direct technician-to-technician access through a dedicated phone line
    • 24x7x365 remote support
    • Single point of contact service
    • End to end case management
    • Third-party collaborative software support
    • Online case tools and live chat support
    • On-demand remote system analysis
  • Warranty Upgrade (Preconfigured Support)

    Services are available to meet the on-site response time targets that match the criticality of your systems.

    • 3, 4, or 5 years of service coverage
    • 1-year or 2-year post-warranty extensions
    • Foundation Service: 9x5 service coverage with next business day onsite response. YourDrive YourData is an optional extra (see below).
    • Essential Service: 24x7 service coverage with 4-hour onsite response or 24-hour committed repair (available only in select markets). Bundled with YourDrive YourData.
    • Advanced Service: 24x7 service coverage with 2-hour onsite response or 6-hour committed repair (available only in select markets). Bundled with YourDrive YourData.
  • Managed Services

    Lenovo Managed Services provides continuous 24x7 remote monitoring (plus 24x7 call center availability) and proactive management of your data center using state-of-the-art tools, systems, and practices by a team of highly skilled and experienced Lenovo services professionals.

    Quarterly reviews check error logs, verify firmware & OS device driver levels, and software as needed. We’ll also maintain records of latest patches, critical updates, and firmware levels, to ensure you systems are providing business value through optimized performance.

  • Technical Account Management (TAM)

    A Lenovo Technical Account Manager helps you optimize the operation of your data center based on a deep understanding of your business. You gain direct access to your Lenovo TAM, who serves as your single point of contact to expedite service requests, provide status updates, and furnish reports to track incidents over time. In addition, your TAM will help proactively make service recommendations and manage your service relationship with Lenovo to make certain your needs are met.

  • Enterprise Server Software Support

    Enterprise Software Support is an additional support service providing customers with software support on Microsoft, Red Hat, SUSE, and VMware applications and systems. Around the clock availability for critical problems plus unlimited calls and incidents helps customers address challenges fast, without incremental costs. Support staff can answer troubleshooting and diagnostic questions, address product comparability and interoperability issues, isolate causes of problems, report defects to software vendors, and more.

  • YourDrive YourData

    Lenovo’s YourDrive YourData is a multi-drive retention offering that ensures your data is always under your control, regardless of the number of drives that are installed in your Lenovo server. In the unlikely event of a drive failure, you retain possession of your drive while Lenovo replaces the failed drive part. Your data stays safely on your premises, in your hands. The YourDrive YourData service can be purchased in convenient bundles and is optional with Foundation Service. It is bundled with Essential Service and Advanced Service.

  • Health Check

    Having a trusted partner who can perform regular and detailed health checks is central to maintaining efficiency and ensuring that your systems and business are always running at their best. Health Check supports Lenovo-branded server, storage, and networking devices, as well as select Lenovo-supported products from other vendors that are sold by Lenovo or a Lenovo-Authorized Reseller.

Examples of region-specific warranty terms are second or longer business day parts delivery or parts-only base warranty.

If warranty terms and conditions include onsite labor for repair or replacement of parts, Lenovo will dispatch a service technician to the customer site to perform the replacement. Onsite labor under base warranty is limited to labor for replacement of parts that have been determined to be field-replaceable units (FRUs). Parts that are determined to be customer-replaceable units (CRUs) do not include onsite labor under base warranty.

If warranty terms include parts-only base warranty, Lenovo is responsible for delivering only replacement parts that are under base warranty (including FRUs) that will be sent to a requested location for self-service. Parts-only service does not include a service technician being dispatched onsite. Parts must be changed at customer’s own cost and labor and defective parts must be returned following the instructions supplied with the spare parts.

Lenovo Service offerings are region-specific. Not all preconfigured support and upgrade options are available in every region. For information about Lenovo service upgrade offerings that are available in your region, refer to the following resources:

For service definitions, region-specific details, and service limitations, please refer to the following documents:

Services

Lenovo Services is a dedicated partner to your success. Our goal is to reduce your capital outlays, mitigate your IT risks, and accelerate your time to productivity.

Note: Some service options may not be available in all markets or regions. For more information, go to https://www.lenovo.com/services. For information about Lenovo service upgrade offerings that are available in your region, contact your local Lenovo sales representative or business partner.

Here’s a more in-depth look at what we can do for you:

  • Asset Recovery Services

    Asset Recovery Services (ARS) helps customers recover the maximum value from their end-of-life equipment in a cost-effective and secure way. On top of simplifying the transition from old to new equipment, ARS mitigates environmental and data security risks associated with data center equipment disposal. Lenovo ARS is a cash-back solution for equipment based on its remaining market value, yielding maximum value from aging assets and lowering total cost of ownership for your customers. For more information, see the ARS page, https://lenovopress.com/lp1266-reduce-e-waste-and-grow-your-bottom-line-with-lenovo-ars.

  • Assessment Services

    An Assessment helps solve your IT challenges through an onsite, multi-day session with a Lenovo technology expert. We perform a tools-based assessment which provides a comprehensive and thorough review of a company's environment and technology systems. In addition to the technology based functional requirements, the consultant also discusses and records the non-functional business requirements, challenges, and constraints. Assessments help organizations like yours, no matter how large or small, get a better return on your IT investment and overcome challenges in the ever-changing technology landscape.

  • Design Services

    Professional Services consultants perform infrastructure design and implementation planning to support your strategy. The high-level architectures provided by the assessment service are turned into low level designs and wiring diagrams, which are reviewed and approved prior to implementation. The implementation plan will demonstrate an outcome-based proposal to provide business capabilities through infrastructure with a risk-mitigated project plan.

  • Basic Hardware Installation

    Lenovo experts can seamlessly manage the physical installation of your server, storage, or networking hardware. Working at a time convenient for you (business hours or off shift), the technician will unpack and inspect the systems on your site, install options, mount in a rack cabinet, connect to power and network, check and update firmware to the latest levels, verify operation, and dispose of the packaging, allowing your team to focus on other priorities.

  • Deployment Services

    When investing in new IT infrastructures, you need to ensure your business will see quick time to value with little to no disruption. Lenovo deployments are designed by development and engineering teams who know our Products & Solutions better than anyone else, and our technicians own the process from delivery to completion. Lenovo will conduct remote preparation and planning, configure & integrate systems, validate systems, verify and update appliance firmware, train on administrative tasks, and provide post-deployment documentation. Customer’s IT teams leverage our skills to enable IT staff to transform with higher level roles and tasks.

  • Integration, Migration, and Expansion Services

    Move existing physical & virtual workloads easily, or determine technical requirements to support increased workloads while maximizing performance. Includes tuning, validation, and documenting ongoing run processes. Leverage migration assessment planning documents to perform necessary migrations.

Regulatory compliance

The SE350 V2 conforms to the following standards:

  • ANSI/UL62368-1
  • IEC 62368-1 (CB Certificate and CB Test Report)
  • FCC - Verified to comply with Part 15 of the FCC Rules, Class A
  • Canada ICES-003, issue 7, Class A
  • CSA C22.2 No. 62368-1
  • CISPR 32, Class A, CISPR 35
  • Japan VCCI, Class A
  • Taiwan BSMI CNS15936, Class A; CNS15598-1; Section 5 of CNS15663
  • CE, UKCA Mark (EN55032 Class A, EN62368-1, EN55024, EN55035, EN61000-3-2, EN61000-3-3, (EU) 617/2013, and EN IEC 63000 (RoHS))
  • Korea KN32, Class A, KN35
  • Russia, Belorussia and Kazakhstan, TP EAC 037/2016 (for RoHS)
  • Russia, Belorussia and Kazakhstan, EAC: TP TC 004/2011 (for Safety); TP TC 020/2011 (for EMC)
  • EAC Russia, Belorussia and Kazakhstan, TR CU 020/2011 and TR CU 004/2011
  • Australia/New Zealand AS/NZS CISPR 32, Class A; AS/NZS 62368.1
  • UL Green Guard, UL2819
  • China CCC certificate, GB17625.1; GB4943.1; GB/T9254.1
  • China CECP certificate, CQC3135
  • China CELP certificate, HJ 2507-2011
  • Japanese Energy-Saving Act
  • Mexico NOM-019
  • TUV-GS (EN62368-1, and EK1-ITB2000)
  • India BIS 13252 (Part 1)
  • Germany GS
  • Brazil INMETRO
  • South Africa NRCS LOA
  • Ukraine UkrCEPRO
  • Morocco CMIM Certification (CM)

Top-of-rack Ethernet switches

The server supports the top-of-rack Ethernet switches that are listed in the following table. These switches have front-to-rear (reverse) airflow for use with servers where the networking ports are at the front of the server.

Table 44. Top-of-rack switches

Part number Description
1 Gb top-of-rack switches
7Y810012WW Lenovo ThinkSystem NE0152T RackSwitch (Front to Rear)
715952F Lenovo RackSwitch G8052 (Front to Rear)
10 Gb top-of-rack switches
7159A2X Lenovo ThinkSystem NE1032 RackSwitch (Front to Rear)
7159B2X Lenovo ThinkSystem NE1032T RackSwitch (Front to Rear)
7159C2X Lenovo ThinkSystem NE1072T RackSwitch (Front to Rear)
715964F Lenovo RackSwitch G8264 (Front to Rear)
7159DFX Lenovo RackSwitch G8264CS (Front to Rear)
7159CFV Lenovo RackSwitch G8272 (Front to Rear)
7159GR5 Lenovo RackSwitch G8296 (Front to Rear)
7159BF7 Lenovo RackSwitch G8124E (Front to Rear)
25 Gb top-of-rack switches
7159E2X Lenovo ThinkSystem NE2572 RackSwitch (Front to Rear)
40 Gb top-of-rack switches
7159BFX Lenovo RackSwitch G8332 (Front to Rear)
100 Gb top-of-rack switches
7159D2X Lenovo ThinkSystem NE10032 RackSwitch (Front to Rear)

For more information, see the list of Product Guides in the Top-of-rack switches categories:

Uninterruptible power supply units

The following table lists the uninterruptible power supply (UPS) units that are offered by Lenovo.

Table 45. Uninterruptible power supply units
Part number Description
55941AX RT1.5kVA 2U Rack or Tower UPS (100-125VAC)
55941KX RT1.5kVA 2U Rack or Tower UPS (200-240VAC)
55942AX RT2.2kVA 2U Rack or Tower UPS (100-125VAC)
55942KX RT2.2kVA 2U Rack or Tower UPS (200-240VAC)
55943AX RT3kVA 2U Rack or Tower UPS (100-125VAC)
55943KX RT3kVA 2U Rack or Tower UPS (200-240VAC)
55945KX RT5kVA 3U Rack or Tower UPS (200-240VAC)
55946KX RT6kVA 3U Rack or Tower UPS (200-240VAC)
55948KX RT8kVA 6U Rack or Tower UPS (200-240VAC)
55949KX RT11kVA 6U Rack or Tower UPS (200-240VAC)
55948PX RT8kVA 6U 3:1 Phase Rack or Tower UPS (380-415VAC)
55949PX RT11kVA 6U 3:1 Phase Rack or Tower UPS (380-415VAC)
55943KT† ThinkSystem RT3kVA 2U Standard UPS (200-230VAC) (2x C13 10A, 2x GB 10A, 1x C19 16A outlets)
55943LT† ThinkSystem RT3kVA 2U Long Backup UPS (200-230VAC) (2x C13 10A, 2x GB 10A, 1x C19 16A outlets)
55946KT† ThinkSystem RT6kVA 5U UPS (200-230VAC) (2x C13 10A outlets, 1x Terminal Block output)
5594XKT† ThinkSystem RT10kVA 5U UPS (200-230VAC) (2x C13 10A outlets, 1x Terminal Block output)

† Only available in China and the Asia Pacific market.

For more information, see the list of Product Guides in the UPS category:
https://lenovopress.com/servers/options/ups

Power distribution units

The following table lists the power distribution units (PDUs) that are offered by Lenovo.

Table 46. Power distribution units
Part
number
Feature
code
Description
ANZ
ASEAN
Brazil
EET
MEA
RUCIS
WE
HTK
INDIA
JAPAN
LA
NA
PRC
0U Basic PDUs
00YJ776 ATZY 0U 36 C13/6 C19 24A 1 Phase PDU N Y Y N N N N N N Y Y Y N
00YJ779 ATZX 0U 21 C13/12 C19 48A 3 Phase PDU N N Y N N N Y N N Y Y Y N
00YJ777 ATZZ 0U 36 C13/6 C19 32A 1 Phase PDU Y Y N Y Y Y Y Y Y N N Y Y
00YJ778 AU00 0U 21 C13/12 C19 32A 3 Phase PDU Y Y N Y Y Y Y Y Y N N Y Y
0U Switched and Monitored PDUs
00YJ783 AU04 0U 12 C13/12 C19 Switched and Monitored 48A 3 Phase PDU N N Y N N N Y N N Y Y Y N
00YJ781 AU03 0U 20 C13/4 C19 Switched and Monitored 24A 1 Phase PDU N N Y N Y N Y N N Y Y Y N
00YJ782 AU02 0U 18 C13/6 C19 Switched and Monitored 32A 3 Phase PDU Y Y Y Y Y Y Y Y Y N Y N Y
00YJ780 AU01 0U 20 C13/4 C19 Switched and Monitored 32A 1 Phase PDU Y Y Y Y Y Y Y Y Y N Y N Y
1U Switched and Monitored PDUs
4PU7A81117 BNDV 1U 18 C19/C13 switched and monitored 48A 3P WYE PDU - ETL N N N N N N N N N N N Y N
4PU7A77467 BLC4 1U 18 C19/C13 Switched and Monitored 80A 3P Delta PDU N N N N N N N N N Y N Y N
4PU7A77469 BLC6 1U 12 C19/C13 switched and monitored 60A 3P Delta PDU N N N N N N N N N N N Y N
4PU7A77468 BLC5 1U 12 C19/C13 switched and monitored 32A 3P WYE PDU Y Y Y Y Y Y Y Y Y N Y Y Y
4PU7A81118 BNDW 1U 18 C19/C13 switched and monitored 48A 3P WYE PDU - CE Y Y Y Y Y Y Y Y Y N Y N Y
46M4002 5896 1U 9 C19/3 C13 Switched and Monitored DPI PDU Y Y Y Y Y Y Y Y Y Y Y Y Y
46M4004 5894 1U 12 C13 Switched and Monitored DPI PDU Y Y Y Y Y Y Y Y Y Y Y Y Y
46M4003 5897 1U 9 C19/3 C13 Switched and Monitored 60A 3 Phase PDU Y Y Y Y Y Y Y Y Y Y Y Y Y
46M4005 5895 1U 12 C13 Switched and Monitored 60A 3 Phase PDU Y Y Y Y Y Y Y Y Y Y Y Y Y
1U Ultra Density Enterprise PDUs (9x IEC 320 C13 + 3x IEC 320 C19 outlets)
71763NU 6051 Ultra Density Enterprise C19/C13 PDU 60A/208V/3PH N N Y N N N N N N Y Y Y N
71762NX 6091 Ultra Density Enterprise C19/C13 PDU Module Y Y Y Y Y Y Y Y Y Y Y Y Y
1U C13 Enterprise PDUs (12x IEC 320 C13 outlets)
39M2816 6030 DPI C13 Enterprise PDU Plus Module (WW) Y Y Y Y Y Y Y Y Y Y Y Y Y
39Y8941 6010 DPI C13 Enterprise PDU Module (WW) Y Y Y Y Y Y Y Y Y Y Y Y Y
1U C19 Enterprise PDUs (6x IEC 320 C19 outlets)
39Y8948 6060 DPI C19 Enterprise PDU Module (WW) Y Y Y Y Y Y Y Y Y Y Y Y Y
39Y8923 6061 DPI Three-phase 60A/208V C19 Enterprise PDU (US) N N Y N N N Y N N N Y Y N
1U Front-end PDUs (3x IEC 320 C19 outlets)
39Y8938 6002 DPI Single-phase 30A/120V Front-end PDU (US) Y Y Y Y Y Y Y Y Y Y Y Y Y
39Y8939 6003 DPI Single-phase 30A/208V Front-end PDU (US) Y Y Y Y Y Y Y Y Y Y Y Y Y
39Y8934 6005 DPI Single-phase 32A/230V Front-end PDU (International) Y Y Y Y Y Y Y Y Y Y Y Y Y
39Y8940 6004 DPI Single-phase 60A/208V Front-end PDU (US) Y N Y Y Y Y Y N N Y Y Y N
39Y8935 6006 DPI Single-phase 63A/230V Front-end PDU (International) Y Y Y Y Y Y Y Y Y Y Y Y Y
1U NEMA PDUs (6x NEMA 5-15R outlets)
39Y8905 5900 DPI 100-127V NEMA PDU Y Y Y Y Y Y Y Y Y Y Y Y Y
Line cords for 1U PDUs that ship without a line cord
40K9611 6504 4.3m, 32A/380-415V, EPDU/IEC 309 3P+N+G 3ph wye (non-US) Line Cord Y Y Y Y Y Y Y Y Y Y Y Y Y
40K9612 6502 4.3m, 32A/230V, EPDU to IEC 309 P+N+G (non-US) Line Cord Y Y Y Y Y Y Y Y Y Y Y Y Y
40K9613 6503 4.3m, 63A/230V, EPDU to IEC 309 P+N+G (non-US) Line Cord Y Y Y Y Y Y Y Y Y Y Y Y Y
40K9614 6500 4.3m, 30A/208V, EPDU to NEMA L6-30P (US) Line Cord Y Y Y Y Y Y Y Y Y Y Y Y Y
40K9615 6501 4.3m, 60A/208V, EPDU to IEC 309 2P+G (US) Line Cord N N Y N N N Y N N Y Y Y N
40K9617 6505 4.3m, 32A/230V, Souriau UTG Female to AS/NZ 3112 (Aus/NZ) Line Cord Y Y Y Y Y Y Y Y Y Y Y Y Y
40K9618 6506 4.3m, 32A/250V, Souriau UTG Female to KSC 8305 (S. Korea) Line Cord Y Y Y Y Y Y Y Y Y Y Y Y Y

For more information, see the Lenovo Press documents in the PDU category:
https://lenovopress.com/servers/options/pdu

Rack cabinets

The SE350 V2 supports installation in a rack when mounted in either the 1U E1 Enclosure or the 2U E2 Enclosure. See Mounting options for details.

Note: The E2 Enclosure is not supported in the 12U and 18U Micro Data Center rack cabinets.

The following table lists the supported rack cabinets.

Table 47. Rack cabinets
Part number Description
93072RX 25U Standard Rack (1000mm)
93072PX 25U Static S2 Standard Rack (1000mm)
7D6DA007WW ThinkSystem 42U Onyx Primary Heavy Duty Rack Cabinet (1200mm)
7D6DA008WW ThinkSystem 42U Pearl Primary Heavy Duty Rack Cabinet (1200mm)
1410-O42 Lenovo EveryScale 42U Onyx Heavy Duty Rack Cabinet
1410-P42 Lenovo EveryScale 42U Pearl Heavy Duty Rack Cabinet
93604PX 42U 1200mm Deep Dynamic Rack
93614PX 42U 1200mm Deep Static Rack
93634PX 42U 1100mm Dynamic Rack
93634EX 42U 1100mm Dynamic Expansion Rack
93074RX 42U Standard Rack (1000mm)
7D6EA009WW ThinkSystem 48U Onyx Primary Heavy Duty Rack Cabinet (1200mm)
7D6EA00AWW ThinkSystem 48U Pearl Primary Heavy Duty Rack Cabinet (1200mm)
1410-O48 Lenovo EveryScale 48U Onyx Heavy Duty Rack Cabinet
1410-P48 Lenovo EveryScale 48U Pearl Heavy Duty Rack Cabinet

For specifications about these racks, see the Lenovo Rack Cabinet Reference, available from:
https://lenovopress.com/lp1287-lenovo-rack-cabinet-reference

For more information, see the list of Product Guides in the Rack cabinets category:
https://lenovopress.com/servers/options/racks

Notes:

  • The following racks do not support the use of the cable management arm (CMA):
    • 25U racks, type 9307
    • 42U racks, type 9307

KVM console options

The following table lists the supported KVM consoles.

Table 48. KVM console
Part number Description
Consoles
4XF7A84188 ThinkSystem 18.5" LCD Console (with US English keyboard)
4XF7A73009 ThinkSystem 18.5" LCD console (with US English keyboard)
17238BX 1U 18.5" Standard Console (without keyboard - see the next table)

The following table lists the keyboards supported with the 1U 18.5" Standard Console (now withdrawn).

Note: These keyboards are not supported with the ThinkSystem 18.5" LCD Console.

Table 49. Keyboards for 1U 18.5" Standard Console
Part number Description
7ZB7A05469 ThinkSystem Keyboard w/ Int.Pointing Device USB - Arabic 253 RoHS v2
7ZB7A05468 ThinkSystem Keyboard w/ Int. Pointing Device USB - Belg/UK 120 RoHS v2
7ZB7A05206 ThinkSystem Keyboard w/ Int. Pointing Device USB - Czech 489 RoHS v2
7ZB7A05207 ThinkSystem Keyboard w/ Int. Pointing Device USB - Danish 159 RoHS v2
7ZB7A05208 ThinkSystem Keyboard w/ Int. Pointing Device USB - Dutch 143 RoHS v2
7ZB7A05210 ThinkSystem Keyboard w/ Int. Pointing Device USB - Fr/Canada 445 RoHS v2
7ZB7A05209 ThinkSystem Keyboard w/ Int. Pointing Device USB - French 189 RoHS v2
7ZB7A05211 ThinkSystem Keyboard w/ Int. Pointing Device USB - German 129 RoHS v2
7ZB7A05212 ThinkSystem Keyboard w/ Int. Pointing Device USB - Greek 219 RoHS v2
7ZB7A05213 ThinkSystem Keyboard w/ Int. Pointing Device USB - Hebrew 212 RoHS v2
7ZB7A05214 ThinkSystem Keyboard w/ Int. Pointing Device USB - Hungarian 208 RoHS v2
7ZB7A05215 ThinkSystem Keyboard w/ Int. Pointing Device USB - Italian 141 RoHS v2
7ZB7A05216 ThinkSystem Keyboard w/ Int. Pointing Device USB - Japanese 194 RoHS v2
7ZB7A05217 ThinkSystem Keyboard w/ Int. Pointing Device USB - Korean 413 RoHS v2
7ZB7A05218 ThinkSystem Keyboard w/ Int. Pointing Device USB - LA Span 171 RoHS v2
7ZB7A05219 ThinkSystem Keyboard w/ Int. Pointing Device USB - Norwegian 155 RoHS v2
7ZB7A05220 ThinkSystem Keyboard w/ Int. Pointing Device USB - Polish 214 RoHS v2
7ZB7A05221 ThinkSystem Keyboard w/ Int. Pointing Device USB - Portugese 163 RoHS v2
7ZB7A05222 ThinkSystem Keyboard w/ Int. Pointing Device USB - Russian 441 RoHS v2
7ZB7A05223 ThinkSystem Keyboard w/ Int. Pointing Device USB - Slovak 245 RoHS v2
7ZB7A05231 ThinkSystem Keyboard w/ Int. Pointing Device USB - Slovenian 234 RoHS v2
7ZB7A05224 ThinkSystem Keyboard w/ Int. Pointing Device USB - Spanish 172 RoHS v2
7ZB7A05225 ThinkSystem Keyboard w/ Int. Pointing Device USB - Swed/Finn 153 RoHS v2
7ZB7A05226 ThinkSystem Keyboard w/ Int. Pointing Device USB - Swiss F/G 150 RoHS v2
7ZB7A05227 ThinkSystem Keyboard w/ Int. Pointing Device USB - Thai 191 RoHS v2
7ZB7A05467 ThinkSystem Keyboard with Int. Pointing Device USB - Trad Chinese/US 467 RoHS v2
7ZB7A05228 ThinkSystem Keyboard w/ Int. Pointing Device USB - Turkish 179 RoHS v2
7ZB7A05229 ThinkSystem Keyboard w/ Int. Pointing Device USB - UK Eng 166 RoHS v2
7ZB7A05470 ThinkSystem Keyboard w/ Int. Pointing Device USB - US Eng 103P RoHS v2
7ZB7A05230 ThinkSystem Keyboard w/ Int. Pointing Device USB - US Euro 103P RoHS v2

The following table lists the available KVM switches and the options that are supported with them.

Table 50. KVM switches and options
Part number Description
KVM Console switches
1754D1T ThinkSystem Digital 2x1x16 KVM Switch (DVI video output port)
1754A1T ThinkSystem Analog 1x8 KVM Switch (DVI video output port)
1754D2X Global 4x2x32 Console Manager (GCM32)
1754D1X Global 2x2x16 Console Manager (GCM16)
1754A2X Local 2x16 Console Manager (LCM16)
1754A1X Local 1x8 Console Manager (LCM8)
Cables for ThinkSystem Digital and Analog KVM Console switches
4X97A11108 ThinkSystem VGA to DVI Conversion Cable
4X97A11109 ThinkSystem Single-USB Conversion Cable for Digital KVM
4X97A11107 ThinkSystem Dual-USB Conversion Cable for Digital KVM
4X97A11106 ThinkSystem USB Conversion Cable for Analog KVM
Cables for GCM and LCM Console switches
43V6147 Single Cable USB Conversion Option (UCO)
39M2895 USB Conversion Option Pack
46M5383 Virtual Media Conversion Option Gen2 (VCO2)
46M5382 Serial Conversion Option (SCO)

For more information, see the list of Product Guides in the KVM Switches and Consoles category:
http://lenovopress.com/servers/options/kvm

Lenovo Financial Services

Lenovo Financial Services reinforces Lenovo’s commitment to deliver pioneering products and services that are recognized for their quality, excellence, and trustworthiness. Lenovo Financial Services offers financing solutions and services that complement your technology solution anywhere in the world.

We are dedicated to delivering a positive finance experience for customers like you who want to maximize your purchase power by obtaining the technology you need today, protect against technology obsolescence, and preserve your capital for other uses.

We work with businesses, non-profit organizations, governments and educational institutions to finance their entire technology solution. We focus on making it easy to do business with us. Our highly experienced team of finance professionals operates in a work culture that emphasizes the importance of providing outstanding customer service. Our systems, processes and flexible policies support our goal of providing customers with a positive experience.

We finance your entire solution. Unlike others, we allow you to bundle everything you need from hardware and software to service contracts, installation costs, training fees, and sales tax. If you decide weeks or months later to add to your solution, we can consolidate everything into a single invoice.

Our Premier Client services provide large accounts with special handling services to ensure these complex transactions are serviced properly. As a premier client, you have a dedicated finance specialist who manages your account through its life, from first invoice through asset return or purchase. This specialist develops an in-depth understanding of your invoice and payment requirements. For you, this dedication provides a high-quality, easy, and positive financing experience.

For your region-specific offers, please ask your Lenovo sales representative or your technology provider about the use of Lenovo Financial Services. For more information, see the following Lenovo website:

https://www.lenovo.com/us/en/landingpage/lenovo-financial-services/

Seller training courses

The following sales training courses are offered for employees and partners (login required). Courses are listed in date order.

  1. Lenovo Data Center Product Portfolio
    2024-04-22 | 20 minutes | Employees and Partners
    Details
    Lenovo Data Center Product Portfolio

    This course introduces the Lenovo data center portfolio, and covers servers, storage, storage networking, and software-defined infrastructure products. After completing this course about Lenovo data center products, you will be able to identify product types within each data center family, describe Lenovo innovations that this product family or category uses, and recognize when a specific product should be selected.

    Published: 2024-04-22
    Length: 20 minutes
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning
    Course code: SXXW1110r7
  2. VTT: Management of Low-End Edge - March 2024
    2024-03-13 | 64 minutes | Employees Only
    Details
    VTT: Management of Low-End Edge - March 2024

    XClarity Orchestrator supports the management of both ISG XCC-based servers and IDG low-end edge devices. This session will cover the architecture of the current solution, along with a demo. In addition, a proposed new architecture for future support of low-end edge devices will be covered

    Published: 2024-03-13
    Length: 64 minutes
    Employee link: Grow@Lenovo
    Course code: DVSYS207
  3. Business Problems Addressed with Lenovo Data & Analytics Solutions
    2024-01-31 | 20 minutes | Employees and Partners
    Details
    Business Problems Addressed with Lenovo Data & Analytics Solutions

    Data is the quantities, characters, or symbols on which operations are performed by a computer, which is then stored and transmitted in the form of electrical signals and recorded on magnetic, optical, solid state, or mechanical recording media. All different types of organizations rely more and more on their data to gain valuable insights and improve their business. As expected, they will have challenges with gaining this insight. In this course we will discuss those challenges and problems our customers face and describe how Lenovo Data and Analytics Solutions can help customers solve each problem.

    After completing this training, you will be able to define the following common problems for databases and big data and describe how Lenovo can help customers solve each problem: scalability, management, performance, protection, security, knowledge/skill, and technology evolution.

    After completing this training, you will be able to define the following common problems for databases and big data and describe how Lenovo can help customers solve each problem: scalability, management, performance, protection, security, knowledge/skill, and technology evolution.

    Published: 2024-01-31
    Length: 20 minutes
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning
    Course code: DSOLP200
  4. Family Introduction: Edge Servers
    2024-01-22 | 18 minutes | Employees and Partners
    Details
    Family Introduction: Edge Servers

    This course introduces the concept of edge servers. Edge servers are used at the edge of an IoT environment, where they perform pre-processing of data, and data forwarding to core environments.
    Course Objectives:
    • Describe the Internet of Things (IoT)
    • Define an edge server
    • Discuss edge server features

    Published: 2024-01-22
    Length: 18 minutes
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning
    Course code: SXXW1105
  5. VTT: VMware and Lenovo - Transforming Industries with VMware Edge Compute Jan. 2024
    2024-01-10 | 60 minutes | Employees Only
    Details
    VTT: VMware and Lenovo - Transforming Industries with VMware Edge Compute Jan. 2024

    Join Josh David from VMware and Trent Richardson from Lenovo as they discuss the latest news from Project Bullwark, and what’s new from the VMware Edge Compute Stack. Topics will include VMware Edge real-time capabilities, Edge Orchestration, and more. Josh and Trent will also discuss determining factors when choosing between the ThinkEdge SE350 V2 and ThinkEdge SE360 V2. Together they will explore what lies in the near future for Lenovo and VMware at the Edge.

    Published: 2024-01-10
    Length: 60 minutes
    Employee link: Grow@Lenovo
    Course code: DVEDG210
  6. Partner Technical Webinar - Tech World 23 Review
    2023-12-22 | 60 minutes | Employees and Partners
    Details
    Partner Technical Webinar - Tech World 23 Review

    In this 60-minute replay, Kenny James, Lenovo Channel Sales Engineering Director, joined us to give a Channel CTO’s perspective on this year's Tech World 2023 conference where the theme was AI for All.

    Published: 2023-12-22
    Length: 60 minutes
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning
    Course code: 121523
  7. Basics of the Edge Ecosystem for Sellers
    2023-12-15 | 20 minutes | Employees and Partners
    Details
    Basics of the Edge Ecosystem for Sellers

    The purpose of this learning module is to familiarize Lenovo field sales, inside sales and partners with the Edge ecosystem and how Lenovo fits into the Edge space.

    • Explain the basics of an Edge Ecosystem
    • Articulate the inherent challenges of Edge Computing
    • Present how Lenovo fits in the Edge Ecosystem

    Published: 2023-12-15
    Length: 20 minutes
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning
    Course code: DTEF101
  8. The 10-minute Edge conversation for Lenovo Sellers
    2023-12-14 | 20 minutes | Employees and Partners
    Details
    The 10-minute Edge conversation for Lenovo Sellers

    The purpose of this course is to enable sellers to have a 10 to 15-minute customer conversation addressing the relevancy of Edge solutions to the customer business.

    Learning Objectives:

    • Prepare for the initial customer conversation
    • Hold a 10-minute Edge Operational Technology (OT) conversation
    • Take the appropriate steps to progress the sale

    Published: 2023-12-14
    Length: 20 minutes
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning
    Course code: DTEF103
  9. Intel and Lenovo Bringing AI Everywhere
    2023-12-13 | 50 minutes | Employees Only
    Details
    Intel and Lenovo Bringing AI Everywhere

    Join Patrick Cassleman of Intel as he discusses how Lenovo and Intel can partner to help customers develop and deploy sustainable AI hardware and software from the edge to the cloud. Patrick will discuss Intel’s full AI portfolio, plus available features and tools to help your customers attain sustainable AI.

    Published: 2023-12-13
    Length: 50 minutes
    Employee link: Grow@Lenovo
    Course code: DVEDG209
  10. VTT: Lenovo in the Era of the Edge-June 2023
    2023-12-04 | 60 minutes | Employees and Partners
    Details
    VTT: Lenovo in the Era of the Edge-June 2023

    Join Richard Jenkins from the Lenovo Edge Computing Business Development group as he discusses how Lenovo fits in the era of the Edge. Topics covered in this VTT session include:
    - customer use cases at the Edge
    - the needed consortium to build an Edge Solution
    - Lenovo edge portfolio
    - The advantages of LOC-A and XClarity at the Edge

    Published: 2023-12-04
    Length: 60 minutes
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning
    Course code: DVEDG201
  11. VTT: ThinkEdge SE350V2 and ThinkEdge SE360 V2, Wave 2 - What's new for bringing AI and computing to the source of the data?
    2023-11-03 | 75 minutes | Employees Only
    Details
    VTT: ThinkEdge SE350V2 and ThinkEdge SE360 V2, Wave 2 - What's new for bringing AI and computing to the source of the data?

    Join Aaron Shao, Sr. Product Manager from Lenovo ThinkEdge Business Unit, as he explores details of the added features for the SE350 V2 and SE360 V2 in Wave 2. Aaron will cover generation transition and product selling points as he discusses customer advantages of the SE350 V2 and SE360 V2 in the context of AI and compute.

    Published: 2023-11-03
    Length: 75 minutes
    Employee link: Grow@Lenovo
    Course code: DVEDG207
  12. VTT: Edge Product Innovation, ISVs, and Market trends - AP & PRC, Oct. 2023
    2023-10-12 | 60 minutes | Employees Only
    Details
    VTT: Edge Product Innovation, ISVs, and Market trends - AP & PRC, Oct. 2023

    Join Richard Jenkins from the AP Edge solutions group as he discusses the difference between Industrial Internet of things (IoT) and Operational Technology (OT). Richard takes a look at how both are relevant to combining edge servers with hybrid cloud architecture. Topics include:
    • Integration of ISV Concepts
    • Edge serving clusters and megaclusters
    • Container designs for SE10, SE30 & SE50

    Published: 2023-10-12
    Length: 60 minutes
    Employee link: Grow@Lenovo
    Course code: DVEDG206
  13. VTT: Edge Product Innovation, ISVs, and Market trends - EMEA, LA & NA, Oct. 2023
    2023-10-11 | 60 minutes | Employees Only
    Details
    VTT: Edge Product Innovation, ISVs, and Market trends - EMEA, LA & NA, Oct. 2023

    Join Per Ljungstrom and Anthony Sayers as they discuss the difference between Industrial Internet of things (IoT) and Operational Technology (OT). They look at how both are relevant to combining edge servers with hybrid cloud architecture. Topics include:
    • Integration of ISV Concepts
    • Edge serving clusters and megaclusters
    • Container designs for SE10, SE30 & SE50

    Published: 2023-10-11
    Length: 60 minutes
    Employee link: Grow@Lenovo
    Course code: DVEDG205
  14. Partner Technical Webinar - StorMagic
    2023-10-02 | 60 minutes | Employees and Partners
    Details
    Partner Technical Webinar - StorMagic

    In this 60-minute replay, Wes Ganeko and Craig Collier from StorMagic reviewed the need for Storage at the Edge, StorMagic’s involvement in the Lenovo AI Innovators program and a deep dive into SvSAN, StorMagic’s flagship product for simple hyperconverged storage.

    Published: 2023-10-02
    Length: 60 minutes
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning
    Course code: 092923
  15. Intro to Edge: 3Ws of Edge Computing for Lenovo Sellers
    2023-09-14 | 13 minutes | Employees and Partners
    Details
    Intro to Edge: 3Ws of Edge Computing for Lenovo Sellers

    This course provides fundamental concepts and a learning foundation for those who are new to the data center and to computing at the Edge. It defines where is the Edge, identifies what are the business drivers for edge computing, and discusses why is edge computing important to Lenovo. September 2023

    Published: 2023-09-14
    Length: 13 minutes
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning
    Course code: DTEF100
  16. Lenovo Solutions for the Edge - Who Are the Customers?
    2023-09-14 | 25 minutes | Employees and Partners
    Details
    Lenovo Solutions for the Edge - Who Are the Customers?

    This course is focused on enabling sellers to identify opportunities for Lenovo Edge and Edge AI Solutions. Topics include a general overview of the Lenovo Edge portfolio and recognizing how edge computing can benefit customers.

    Course Objectives:
    • Identify Lenovo Edge Opportunities
    • Recognize how an Edge solution would benefit your customer
    • Provide a general overview of Lenovo solutions at the Edge
    • Identify key points for your customer Edge conversation

    Published: 2023-09-14
    Length: 25 minutes
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning
    Course code: DTEF102
  17. Family Portfolio - Edge
    2023-09-12 | 15 minutes | Employees and Partners
    Details
    Family Portfolio - Edge

    This course introduces edge environments, and the roles played by Lenovo edge servers and edge clients in those environments. It looks briefly at use cases for these edge devices.
    When you have completed this course, you should be able to list the edge solutions in the Lenovo portfolio, describe the features of each solution, and determine which solution is best suited to a specific environment.

    Published: 2023-09-12
    Length: 15 minutes
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning
    Course code: SXXW2513r2
  18. VTT: VMware Edge Compute Stack, August 2023
    2023-08-17 | 60 minutes | Employees Only
    Details
    VTT: VMware Edge Compute Stack, August 2023

    Edge Compute drives business transformation in sectors like retail, manufacturing & utilities. It intersects with IoT sensors, robotics & AI, and supports use cases requiring computing closer to operations. Implementing Edge Compute at scale requires a platform supporting verticalized applications, manageability, reliability & security. Join Josh David from VMware and Alejandro Perez from Lenovo as they discuss how the VMware Edge Stack enables real-time intelligence & immersive experiences at the Edge.

    Published: 2023-08-17
    Length: 60 minutes
    Employee link: Grow@Lenovo
    Course code: DVEDG203
  19. Lenovo Data Center Product Portfolio
    2023-07-21 | 15 minutes | Employees and Partners
    Details
    Lenovo Data Center Product Portfolio

    This course introduces the Lenovo data center portfolio, and covers servers, storage, storage networking, and software-defined infrastructure products. After completing this course about Lenovo data center products, you will be able to identify product types within each data center family, describe Lenovo innovations that this product family or category uses, and recognize when a specific product should be selected.

    Published: 2023-07-21
    Length: 15 minutes
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning
    Course code: SXXW1110r6
  20. VTT: SAP HANA Transition and Refresh Opportunity - July 2023
    2023-07-14 | 60 minutes | Employees Only
    Details
    VTT: SAP HANA Transition and Refresh Opportunity - July 2023

    In this session, we cover:
    - What Next for SAP Clients?
    - Lenovo Opportunity
    - Lenovo Portfolio for SAP Solutions
    - RISE with SAP

    Published: 2023-07-14
    Length: 60 minutes
    Employee link: Grow@Lenovo
    Course code: DVDAT202
  21. Partner Technical Webinar - ThinkEdge SE350 V2 & SE360 V2 Update
    2023-07-13 | 60 minutes | Employees and Partners
    Details
    Partner Technical Webinar - ThinkEdge SE350 V2 & SE360 V2 Update

    July 7, 2023 – in this 60-minute replay, Benoit Robert, Director - Edge Server Product Management, reviewed the ThinkEdge portfolio specifically the SE350v2 and SE360v2. Benoit discussed the key differences between the 2 edge servers with a focus on form factors and use cases.

    Published: 2023-07-13
    Length: 60 minutes
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning
    Course code: 070723
  22. Partner Technical Webinar - Server Review with Mark Bica
    2023-06-20 | 60 minutes | Employees and Partners
    Details
    Partner Technical Webinar - Server Review with Mark Bica

    In this 60-minute replay, Mark Bica, Lenovo ThinkSystem Brand Manager, reviewed currently ThinkSystem Server portfolio. He highlighted recent server announcements including the SE350 V2, SE360 V2 and SR675 V3. Joe Murphy, Lenovo Solution Architect concluded the session with a demo of how to get Estimated Ship Dates in DCSC.

    Published: 2023-06-20
    Length: 60 minutes
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning
    Course code: 061623
  23. FY24Q1 AI Launch
    2023-06-14 | 15 minutes | Employees and Partners
    Details
    FY24Q1 AI Launch

    This course covers the exciting announcements that Lenovo is making about its commitment to AI. Not only has Lenovo pledged to invest $1B in AI over the next three years, and committed $100M to bolster the Lenovo AI Innovators Program, but there are also some exciting product announcements.

    Once you complete this course, you should be able to define intelligence and artificial intelligence, describe a digital twin, and discuss the three key points of the Lenovo AI launch: investment in AI, a new AI-capable data center server, and new AI-capable edge servers.

    Published: 2023-06-14
    Length: 15 minutes
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning
    Course code: SXXW2516
  24. Lenovo XClarity Management Hub for Edge Server Devices
    2023-06-08 | 50 minutes | Employees and Partners
    Details
    Lenovo XClarity Management Hub for Edge Server Devices

    This course offers a comprehensive overview and demonstration of the enhanced capability to manage ThinkEdge Server Devices through Lenovo XClarity Management Hub in Lenovo XClarity Orchestrator (LXCO).

    Published: 2023-06-08
    Length: 50 minutes
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning
    Course code: DXCO201
  25. Lenovo XClarity Management Hub for Edge Client Devices
    2023-06-08 | 50 minutes | Employees and Partners
    Details
    Lenovo XClarity Management Hub for Edge Client Devices

    This course offers a comprehensive overview and demonstration of the enhanced capability to manage ThinkEdge Client Devices through Lenovo XClarity Management Hub in Lenovo XClarity Orchestrator (LXCO).

    Published: 2023-06-08
    Length: 50 minutes
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning
    Course code: DXCO202
  26. Family Portfolio: Intel Edge Servers
    2023-06-07 | 15 minutes | Employees and Partners
    Details
    Family Portfolio: Intel Edge Servers

    This course introduces two new Lenovo ThinkEdge servers: the ThinkEdge SE350 V2 and ThinkEdge SE360 V2.
    After completing this course, you will be able to list the Intel edge servers in the Lenovo portfolio, describe the features of each server and determine which server is best suited to a specific environment.

    Published: 2023-06-07
    Length: 15 minutes
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning
    Course code: SXXW2510r2
  27. Lenovo FY24Q2 AI Announcement QH
    2023-06-07 | 3 minutes | Employees and Partners
    Details
    Lenovo FY24Q2 AI Announcement QH

    This Quick Hit covers the exciting announcements Lenovo is making about its commitment to AI. Lenovo has pledged to invest $1B in AI over the next three years, and has committed $100M to bolster the Lenovo AI Innovators Program to develop AI-Ready solutions faster. Two new servers are being added to the already impressive Lenovo Edge portfolio – the ThinkEdge SE350 V2 and ThinkEdge SE360 V2. These servers offer a wide operating temperature range and the ruggedness to handle shock, vibration, and airborne contaminants. The SE360 V2 supports GPUs, making it ideal for AI at the edge. Both servers support the new time-sensitive networking protocol, TSN, to ensure that response times are low and deterministic.
    Note: This course is presented as audio only. There are no slides or video.

    Published: 2023-06-07
    Length: 3 minutes
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning
    Course code: SXXW2516a
  28. Partner Technical Webinar - Smart Cities with ThinkEdge
    2022-12-13 | 60 minutes | Partners Only
    Details
    Partner Technical Webinar - Smart Cities with ThinkEdge

    In this 60-minute replay, Alejandro Perez, Lenovo Americas Edge Solutions Leader, discussed the Edge applications of Smart Cities, specifically the City of Barcelona. Alejandro reviewed the key uses of the solution and the underlying architecture including the Lenovo SE350, SE450 and Lenovo Open Cloud Automation software.

    Published: 2022-12-13
    Length: 60 minutes
    Partner link: Lenovo Partner Learning
    Course code: 120922
  29. Technical Champions Webinar: Edge Computing Enables New Possibilities
    2022-12-09 | 64 minutes | Employees Only
    Details
    Technical Champions Webinar: Edge Computing Enables New Possibilities

    The Lenovo launch of both ThinkEdge SE350 and SE450 helps to resolve edge computing requirements and enables new possibilities for a variety of verticals. Join Aaron Shao, Lenovo Edge Product Manager, as he discusses the big picture of edge computing and positioning of the Lenovo ThinkEdge portfolio. Aaron will take a deep dive into the latest news from the most GPU rich edge server in the industry, the Lenovo ThinkEdge SE450. Two outstanding customer stories and their application of Edge computing will also be featured as well.

    Published: 2022-12-09
    Length: 64 minutes
    Employee link: Grow@Lenovo
    Course code: DTEO101
  30. Technical Champions Webinar: Lenovo Edge Solutions: Unleash the Power of AI Solutions at the Edge
    2022-10-13 | 60 minutes | Employees and Partners
    Details
    Technical Champions Webinar: Lenovo Edge Solutions: Unleash the Power of AI Solutions at the Edge

    View this Technical Champions Webinar (recorded October 10, 2022) to learn about Lenovo's Edge solutions. Join Alejandro Perez Quintero as he discusses the elements of Edge computing, the growth of the Edge and the connection with AI.

    This webinar covers:
    - Drivers for Edge Technology
    - Lenovo Edge Solutions
    - Customer use cases

    Published: 2022-10-13
    Length: 60 minutes
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning
    Course code: DEDGP100

1-10 of 30 courses.

Related product families

Product families related to this document are the following:

Trademarks

Lenovo and the Lenovo logo are trademarks or registered trademarks of Lenovo in the United States, other countries, or both. A current list of Lenovo trademarks is available on the Web at https://www.lenovo.com/us/en/legal/copytrade/.

The following terms are trademarks of Lenovo in the United States, other countries, or both:
Lenovo®
Bootable Media Creator
Flex System
Lenovo Services
RackSwitch
ServerProven®
System x®
ThinkAgile®
ThinkEdge®
ThinkShield®
ThinkServer®
ThinkSystem®
TruDDR4
UpdateXpress System Packs
XClarity®

The following terms are trademarks of other companies:

Intel® and Xeon® are trademarks of Intel Corporation or its subsidiaries.

Linux® is the trademark of Linus Torvalds in the U.S. and other countries.

Microsoft®, ActiveX®, Azure®, Hyper-V®, PowerShell, Windows PowerShell®, Windows Server®, and Windows® are trademarks of Microsoft Corporation in the United States, other countries, or both.

Other company, product, or service names may be trademarks or service marks of others.