Author
Updated
17 Nov 2023Form Number
LP1676PDF size
71 pages, 2.7 MB- Introduction
- Did you know?
- Key features
- View in Augmented Reality
- Components and connectors
- System architecture
- Standard specifications
- Models
- Processors
- Memory options
- I/O expansion
- Internal storage
- Controllers for internal storage
- Internal drive options
- Optical drive
- Network Modules
- Network adapters
- GPU adapters
- Cooling
- Power supplies
- Systems management
- Security
- Mounting options
- Operating system support
- Physical and electrical specifications
- Operating environment
- Warranty and Support
- Services
- Regulatory compliance
- Top-of-rack Ethernet switches
- Uninterruptible power supply units
- Power distribution units
- Rack cabinets
- KVM console options
- Lenovo Financial Services
- Seller training courses
- Related publications and links
- Related product families
- Trademarks
Abstract
The SE350 V2 is a purpose-built server that is half the width and significantly shorter than a traditional server, small footprint making it ideal for deployment in tight spaces. It can be mounted on a wall, ceiling mount, placed on a shelf or mounted in a rack. The ThinkEdge SE350 V2 server puts increased processing power, storage and network closer to where data is generated. For customers that want to install server outside data center looking for reduced latency by processing at the edge.
This product guide provides essential pre-sales information to understand the ThinkEdge SE350 V2 server, its key features and specifications, components and options, and configuration guidelines. This guide is intended for technical specialists, sales specialists, sales engineers, IT architects, and other IT professionals who want to learn more about the SE350 V2 and consider its use in IT solutions.
Change History
Changes in the November 17, 2023 update:
- Added back supported ESXi version under Operating system support section
- VMware ESXi 8.0 U1
- Added a new power table details under Mounting options section
Introduction
The ThinkEdge SE350 V2 is a purpose-built server that is half the width and significantly shorter than a traditional server, making it ideal for deployment in tight spaces. It can be mounted on a wall, ceiling mount, placed on a desk or mounted in a rack. The ThinkEdge SE350 V2 puts increased processing power, storage and network closer to where data is generated, allowing actions resulting from the analysis of that data to take place more quickly.
Target workloads for the manufacturing, industrial and retail markets: hybrid clouds at the edge deployment, virtualization, NFV, workload consolidation, web host, management server, edge storage server.
Did you know?
The ThinkEdge SE350 V2 fits those customers that want to install a server outside the data center looking for reduced latency by processing at the edge, avoiding transmission of data between the core and edge where possible and also adhering to the regulatory security requirements of the geography and industry by storing and analyzing data at the edge. The ThinkEdge SE350 V2 has a compact design, low power usage, and high performance are just the right combination for edge locations. It can be wall mounted, placed on a desk or installed in a rack. It is also designed to operate in a semi rugged environment, 0°C to 55°C, dust and vibration.
Key features
The ThinkEdge SE350 V2 is a purpose-built server that is half the width and significantly shorter than a traditional server, making it ideal for deployment in tight spaces. The 3.2 liter case can be mounted on a wall, ceiling mount, placed on desk or mounted in a rack.
The ThinkEdge SE350 V2 puts increased processing power, storage and network closer to where data is generated, allowing actions resulting from the analysis of that data to take place more quickly. The server has wired connections up to 25GbE.
Since these edge servers are typically deployed outside of secure data centers, they include technology that encrypts the data stored on the device if it is tampered with, only enabling authorized users to access it.
Scalability and performance
The SE350 V2 offers numerous features to boost performance, improve scalability and reduce costs:
- Support a single processor from the Intel Xeon D Processor family. Supports processors up to 16 cores, core speeds of up to 2.1 GHz, and TDP ratings of up to 100W.
- Intelligent and adaptive system performance with Intel Technology 2.0 allows processor cores to run at maximum speeds during peak workloads by temporarily going beyond processor TDP.
- Intel Hyper-Threading Technology boosts performance for multithreaded applications by enabling simultaneous multithreading within each processor core, up to two threads per core.
- Intel Virtualization Technology integrates hardware-level virtualization hooks that allow operating system vendors to better use the hardware for virtualization workloads.
- Support for up to 4 TruDDR4 memory DIMMs an up to 256 GB of memory using 64 GB DIMMs.
- Up to 4 x SATA/NVMe 2.5-inch 7mm HS drives; 2 x 2.5-inch 15mm HS drives.
- Supports 1 or 2 additional M.2 NVMe drives for OS boot and applications (RAID 1), allowing the convenience of separating application code from data.
- The use of NVMe drives increased performance over SATA drives, in terms of throughput, bandwidth, and latency.
- 1GbE I/O board or 10 GbE/25GbE SFP28 I/O board to support low and high-speed networking to back-end servers.
- No PCIe slot (no GPU support, no optional Network Adapters support).
Availability and serviceability
The SE350 V2 provides many features to simplify serviceability and increase system uptime:
- Supports remote management, including remote control functions down to the UEFI level (most models) makes managing the edge servers easy even without onsite IT personnel.
- ECC memory and memory RAS features.
- Two redundant external AC Adapter power supplies and three fans to provide improved availability.
- Built-in XClarity Controller continuously monitors system parameters, triggers alerts, and performs recovery actions in case of failures to minimize downtime.
- Built-in diagnostics in UEFI, using Lenovo XClarity Provisioning Manager, speed up troubleshooting tasks to reduce service time.
- Lenovo XClarity Provisioning Manager collects and saves service data to USB key drive or remote CIFS share folder, for troubleshooting and to reduce service time.
- Auto restart in the event of a loss of AC power
- Support for the XClarity Administrator Mobile app running on a supported smartphone and connected to the server through the service-enabled USB port, enables additional local systems management functions.
- Three-year customer-replaceable unit and onsite limited warranty, 9 x 5 next business day. Optional service upgrades are available.
Manageability and security
Systems management features simplify local and remote management of the SE350 V2:
- The server includes XClarity Controller 2 (XCC2) to monitor server availability. Optional upgrade to XCC Platinum to provide remote control (keyboard video mouse) functions, support for the mounting of remote media files (ISO and IMG image files), boot capture, power capping and new XCC2 Platinum features. New XCC2 Platinum features include System Guard, new security modes including a CNSA-compliant mode, FIPS 140-3 and NIST 800-193 support, and a new Neighbor Group feature.
- Lenovo XClarity Administrator offers comprehensive hardware management tools that help to increase uptime, reduce costs and improve productivity through advanced server management capabilities.
- IT Administrators can securely claim and activate the SE350 V2 remotely through the ThinkShield Key Vault Portal, available on the web. They can also manage and unlock their global IoT edge fleet for initial operation and in case of tamper. The ThinkShield Edge Mobile Management app enables Edge Users to securely claim and activate the ThinkSystem SE350 V2 in an easy to use Web UI.
- New UEFI-based Lenovo XClarity Provisioning Manager, accessible from F1 during boot, provides system inventory information, graphical UEFI Setup, platform update function, RAID Setup wizard, operating system installation function, and diagnostic functions.
- Support for Lenovo XClarity Energy Manager, which captures real-time power and temperature data from the server and provides automated controls to lower energy costs.
- Integrated Trusted Platform Module (TPM) 2.0 support enables advanced cryptographic methods, such as digital signatures and remote attestation.
- Supports Secure Boot to ensure only a digitally signed operating system can be used.
- Industry-standard Advanced Encryption Standard (AES) NI support for faster, stronger encryption.
- Intel Execute Disable Bit functionality can prevent certain classes of malicious buffer overflow attacks when combined with a supported operating system.
- Intel Trusted Execution Technology provides enhanced security through hardware-based resistance to malicious software attacks, allowing an application to run in its own isolated space, protected from all other software running on a system.
View in Augmented Reality
View the SE350 V2 in augmented reality (AR) using your smartphone or tablet.
Simply follow these steps:
- Scan the QR code with the camera app on your phone*
- Point your phone at a flat surface
- Wait a few seconds for the model to appear
* If you're viewing this document on your phone or tablet, simply tap the QR code
Once the server appears, you can move your phone around it. You can also drag or rotate the server to reposition it.
Components and connectors
The ports on the front of the ThinkEdge SE350 V2 server depend on which network module is installed.
The following figure shows server with the 1GbE network module installed. With this network module, the server has wired connectivity capabilities. Four 1GbE Ethernet ports, two 2.5 Gigabit Ethernet ports, and 1 port for management LAN.
Figure 2. Front view of the ThinkEdge SE350 V2 server with 4 x 7mm 2.5” HS and 1GbE network module
The following figure shows server with the 10/25 GbE network module installed. With this network module, the server has wired connectivity capabilities. Four 10/25 GbE SFP28 ports, two 2.5 Gigabit Ethernet ports, and 1 port for management LAN.
Figure 3. Front view of the ThinkEdge SE350 V2 server with 4 x 7mm 2.5” HS and 10/25 GbE network module
The following figure shows server with 1GbE module, 1GbE Ethernet ports, two 2.5 Gigabit Ethernet ports, and 1 port for management LAN.
Figure 4. Front view of the ThinkEdge SE350 V2 server with 2 x 15mm 2.5” HS and 1GbE network module.
The following two figures show supported power options for the server.
System architecture
The following figure shows the architectural block diagram of the SE350 V2 system, showing the major components and connections.
Tip: The wrench icons show where the local and remote management functions are enabled
Figure 8. SE350 V2 system board - architectural block diagram
The system board connects to a network module which provides all wired network connections. Two network modules are offered. The block diagrams are shown in the following figures. All wired connections are at the front of the server.
Figure 9. SE350 V2 network modules - architectural block diagrams
Standard specifications
The following table lists the standard specifications.
Components | Specification |
---|---|
Machine types | 7DA9 - SE350 V2 - 3 year warranty 7DBK - Lenovo ThinkEdge SE350 V2 1U2N and 2U2N Enclosure - 3 year warranty |
Form factor | Edge server, 1U high |
Processor | One Intel Xeon D-2700 Series processor (formerly codenamed "Icelake D"). Supports processors up to 16 cores, core speeds of up to 2.1 GHz, and TDP ratings of up to 100W. Processor is soldered onto system board. |
Memory | 4 DIMM slots. The processor has 4 memory channels, with 1 DIMM per channel. Lenovo TruDDR4 DIMMs operating at 3200 MHz. RDIMMs are supported |
Memory maximum | Up to 256GB with 4x 64 GB RDIMMs |
Memory protection | ECC, SDDC (for x4-based memory DIMMs) |
Drive bays |
2.5-inch 7mm drive bays:
2.5-inch 15mm drive bays:
Internal drives for OS boot:
|
Maximum data storage |
NVMe drives:
SATA drives:
|
Storage controller |
|
Network interfaces |
Networking depends the network module selected:
|
PCI Expansion slots | None |
Ports |
Front: 2x USB 3.2 G1 Type-A ports, 1x USB 3.2 G1 Type-C port (for display), 1x USB 2.0 G1 Type-C port for local systems management. Rear: power connectors, 1x RJ-45 RS-232 serial console connector, PMB status LED, 2x threaded studs for grounding. |
Cooling | Three non-hot-swap 40 mm fans (all 3 standard), N+1 redundant in most configurations. |
Video | Embedded graphics with 16 MB memory with 2D hardware accelerator, integrated into the XClarity Controller 2 management controller. Maximum resolution is 1920x1200 32bpp at 60Hz. |
Power supply |
Choices for power input:
|
Systems management | Operator panel with status LEDs. Dedicated ports for local management (USB type-C for use with mobile app) and remote management (RJ45 Ethernet ports). Remote management can also be performed. XClarity Controller 2 (XCC2) embedded management controller, XClarity Administrator centralized infrastructure delivery, XClarity Integrator plugins, and XClarity Energy Manager centralized server power management. Optional XClarity Controller Advanced to enable remote control functions. ThinkShield Edge Mobile Management mobile app and XClarity Mobile app for local onsite SE350 V2 server management. |
Security features | ThinkShield Key Vault Portal web site for security management. Trusted Platform Module, supporting TPM 2.0. In China only, optional Nationz TPM 2.0. Front locking bezel, Kensington cable slot with intelligent lock position switch, G-sensor trigger for motion detection, intrusion detection, self-encrypting drive (SED) support, power-on password, administrator's password. |
Operating systems supported | Microsoft Windows Server, Red Hat Enterprise Linux, SUSE Linux Enterprise Server, VMware ESXi. Ubuntu Server certification. See the Operating system support section for specifics. |
Mounting options | DIN rail wall mount, ceiling mount, 1U rack mount (2 servers), 2U short-depth rack mount (2 servers). Available locking bezel with dust filter. |
Limited warranty | Three-year customer-replaceable unit and onsite limited warranty with 9x5 next business day (NBD). |
Service and support | Optional service upgrades are available through Lenovo Services: 4-hour or 2-hour response time, 6-hour fix time, 1-year or 2-year warranty extension, software support for Lenovo hardware and some third-party applications. |
Dimensions | Height: 41.7 mm (1.64 in.), width: 209 mm (8.23 in.), depth: 384 mm (15.12 in.) |
Volume | 3.2 liters |
Weight | Maximum: 3.75 kg (8.3 lb) |
Models
ThinkEdge SE350 V2 models can be configured by using the Lenovo Data Center Solution Configurator (DCSC).
Configure-to-order (CTO) models are used to create models with factory-integrated server customizations. One CTO model is available for the SE350 V2 as listed in the following table:
- The CTO1WW base CTO model is for general business and is selectable by choosing General Purpose mode in DCSC.
Description | Machine Type/Model General purpose |
---|---|
ThinkEdge SE350 V2 - 3 year Warranty | 7DA9CTO1WW |
Lenovo ThinkEdge SE350 V2 1U2N Enclosure | 7DBKCTO1WW |
Lenovo ThinkEdge SE350 V2 2U2N Enclosure | 7DBKCTO2WW |
Processors
The SE350 V2 supports processors in the Intel Xeon D-2700 family of processors (formerly codenamed "Icelake D"). The server supports one processor and the processor is soldered on the system board.
The table below lists the supported processors.
All supported processors have the following characteristics:
- AI capable: Intel AVX-512, VNNI, OpenVINO
- Intel Turbo Boost 3.1
- Intel Hyper-Threading Technology
- Intel Virtualization Technology (VT-c, VT-x, VT-d)
- Intel AES New Instructions
- Intel Trusted Execution Technology
- Converged Boot Guard (CBnT)
- Intel Software Guard Extensions (SGX)
- Intel Boot Guard
- Faster Boot with Slim Bootloader
- Time Coordinated Computing (TCC)
Part numbers: There are no part numbers for processors because there are no field upgrades supported.
Feature code* | Description |
---|---|
BS3V / BS40 | ThinkEdge SE350 V2/SE360 V2 Planar with Intel Xeon D-2712T 4C 65W 1.9 GHz |
BS3W / BS41 | ThinkEdge SE350 V2/SE360 V2 Planar with Intel Xeon D-2733NT 8C 80W 2.1 GHz |
BS3X/ BS42 | ThinkEdge SE350 V2/SE360 V2 Planar with Intel Xeon D-2775TE 16C 100W 2.0 GHz |
* The second feature code is for CTO orders from NA and LA geographies, and for Brazil
The following table lists the features of the supported processors.
Intel model | Cores / Threads |
HT | TB | Base Frequency |
Max Turbo Frequency |
L3 Cache | Ethernet mode | Memory channels |
Memory bus |
TDP |
---|---|---|---|---|---|---|---|---|---|---|
D-2712T | 4 | Y | Y | 1.90 GHz | 3.0 GHz | 15 MB | 50 G | 4 | 2667 MHz | 65 W |
D-2733NT | 8 | Y | Y | 2.10 GHz | 3.2 GHz | 15 MB | 50 G | 4 | 2667 MHz | 80 W |
D-2775TE | 16 | Y | Y | 2.00 GHz | 3.1 GHz | 25 MB | 100 G | 4 | 2933 MHz | 100 W |
Note: 10/25GbE I/O module LAN speed depend on CPU ethernet mode, 4x 10GbE (max 50 G) or 4x 25GbE (max 100G)
Note: 20-core processor support: The processors listed here have up to 16 cores. The server also supports 20-core processors, however these are currently only available via special bid/CORE. Please contact your Lenovo sales representative.
Memory options
The server uses processors with 4 memory channels and supports 1 DIMM per channel, for a total of 4 DIMMs. The server supports up to 256GB of memory using 4x 64 GB RDIMMs.
The following table lists the memory options that are available for the server.
Lenovo TruDDR4 memory uses the highest quality components that are sourced from Tier 1 DRAM suppliers and only memory that meets the strict requirements of Lenovo is selected. It is compatibility tested and tuned to maximize performance and reliability. From a service and support standpoint, Lenovo TruDDR4 memory automatically assumes the system warranty, and Lenovo provides service and support worldwide.
Part number |
Feature code |
Description | Minimum supported |
Maximum supported |
---|---|---|---|---|
RDIMMs | ||||
4X77A08634 | B965 | ThinkSystem 32GB TruDDR4 3200 MHz (2Rx8 1.2V) RDIMM | 1 | 4 |
4X77A08633 | B964 | ThinkSystem 32GB TruDDR4 3200 MHz (2Rx4 1.2V) RDIMM | 1 | 4 |
4X77A08632 | B963 | ThinkSystem 16GB TruDDR4 3200 MHz (2Rx8 1.2V) RDIMM | 1 | 4 |
4X77A08635 | B966 | ThinkSystem 64GB TruDDR4 3200 MHz (2Rx4 1.2V) RDIMM | 1 | 4 |
The following rules apply when selecting the memory configuration:
- DIMM installation sequence 1, 4, 2 & 3
- One DIMM per channel only
- Three DIMMs are not supported
- The server supports RDIMMs
- Mix of 2Rx4 and 2Rx8 based DIMMs across channels are not supported
- Mix of 16GB 2Rx8 & 32GB 2Rx8 across channels are supported
- Mix of 32GB 2Rx4 & 64GB 2Rx4 across channels are supported
- Memory mirroring and memory rank sparing are not supported
- Server supports Independent mode
- Rank sparing, ADDC, channel mirroring, hemisphere modes, and 2LM are not supported with Software Guard Extensions (SGX)
The following memory protection technologies are supported:
- ECC detection/correction
- SDDC (for x4-based memory DIMMs; look for "x4" in the DIMM description)
I/O expansion
The SE350 V2 does not support PCIe I/O slots.
Internal storage
The internal storage of the SE350 V2 server is implemented as follows:
- Up to 4x SATA/NVMe 2.5-inch 7mm drives or 2x NVMe 2.5-inch 15mm drives.
- NVMe 2.5-inch drives with PCIe 4.0 interface.
- Boot drives are installed on I/O module with dedicated slot, either one or two 2280 NVMe M.2 drives with PCIe gen3 are supported.
The following modules are supported.
Part number |
Feature code |
Description | 7mm SSD | 15mm SSD |
---|---|---|---|---|
4XF7A86281 | BS48 | ThinkEdge SE350 V2 7mm SSD Module | 0-4 (NVMe/SATA) | -- |
4XF7A86280 | BS47 | ThinkEdge SE350 V2 15mm SSD Module | -- | 0-2 (all NVMe) |
Controllers for internal storage
The SE350 V2 supports the following for internal storage:
- Onboard NVMe controller supporting RAID 0, 1 (with Intel VROC RAID support) - boot drives
- Onboard SATA/NVMe controller supporting RAID 0, 1, 5, 10 (with Intel VROC RAID support) - data drives
Intel VROC onboard RAID
Intel VROC (Virtual RAID on CPU) is a feature of the Intel processor that enables RAID support.
There are two separate functions of VROC in the SE350 V2:
- Intel VROC SATA RAID, formerly known as Intel RSTe
- Intel VROC NVMe RAID
VROC SATA RAID (RSTe) is available and supported with all SATA drives, both SATA SSDs and SATA HDDs. It offers a 6 Gb/s connection to each drive and on the SE350 V2 implements RAID levels 0, 1, 5, and 10. RAID 1 is limited to 2 drives per array, and RAID 10 is limited to 4 drives per array. Hot-spare functionality is also supported.
VROC NVMe RAID offers RAID support for any NVMe drives directly connected to the ports on the server's
system board. On the SE350 V2, it implements RAID levels 0, 1, 5, and 10. RAID 1 is limited to 2 drives per array, and RAID 10 is limited to 4 drives per array. Hot-spare functionality is also supported.
The following options are available as follows:
- VROC NVMe RAID on the SE350 V2 by default is disabled and does not support NVMe RAID. In configurator selecting "none" would mean default, same as JBOD.
- Selecting VROC Standard, feature code BR9B, to support RAID-0/1/10.
- Selecting VROC Premium, feature code B96G, to support RAID-0/1/5/10.
VROC Standard or Premium are fulfilled as a Feature on Demand (FoD) license and is activated via the XCC management processor user interface.
Part number |
Feature code |
Description |
---|---|---|
4L47A39164 | B96G / BS7N | Intel VROC (VMD NVMe RAID) Premium |
4L47A83669 | BR9B / BS7M | Intel VROC (VMD NVMe RAID) Standard |
VROC Premium is only needed on the SE350 V2 for RAID-5 support with NVMe drives. You do not need the VROC Premium license upgrade under any of the following conditions:
- If you have SATA drives connected to the onboard SATA ports, you do not need VROC Premium.
- If you are using RAID 0, 1 or 10 with NVMe drives, you do not need VROC Premium.
Virtualization support: Virtualization support for Intel VROC is as follows:
- VROC SATA RAID (RSTe): VROC SATA RAID is not supported by virtualization hypervisors such as ESXi, KVM, Xen, and Hyper-V. Virtualization is only supported on the onboard SATA ports in AHCI (non-RAID) mode.
- VROC (VMD) NVMe RAID: VROC (VMD) NVMe RAID is supported by ESXi, KVM, Xen, and Hyper-V. ESXi support is limited to RAID 1 only; other RAID levels are not supported. Windows and Linux OSes support VROC RAID NVMe, both for host boot functions and for guest OS function, and RAID-0, 1, 5, and 10 are supported.
Internal drive options
The SE350 V2 supports the following type of drive bays.
- 2.5-inch 7mm drive bays:
- 7mm 2.5-inch hot-swap 6 Gb SATA SSDs
- 7mm 2.5-inch hot-swap PCIe 4.0 NVMe SSDs
- 2.5-inch 15mm drive bays:
- 15mm 2.5-inch hot-swap PCIe 4.0 NVMe SSDs
- M.2 drives for boot:
- 2280 NVMe M.2 drives
The following table lists the supported drive options.
Part number |
Feature code |
Description |
---|---|---|
7mm 2.5-inch hot-swap 6 Gb SATA SSDs | ||
4XB7A17106 | BK79 | ThinkSystem 7mm S4520 240GB Read Intensive SATA 6Gb HS SSD |
4XB7A17107 | BK7A | ThinkSystem 7mm S4520 480GB Read Intensive SATA 6Gb HS SSD |
4XB7A17108 | BK7B | ThinkSystem 7mm S4520 960GB Read Intensive SATA 6Gb HS SSD |
4XB7A78622 | BM8E | ThinkSystem 7mm S4520 1.92TB Read Intensive SATA 6Gb HS SSD |
4XB7A78623 | BM8D | ThinkSystem 7mm S4520 3.84TB Read Intensive SATA 6Gb HS SSD |
4XB7A78624 | BM8C | ThinkSystem 7mm S4520 7.68TB Read Intensive SATA 6Gb HS SSD |
4XB7A82264 | BQ1U | ThinkSystem 7mm 5400 PRO 240GB Read Intensive SATA 6Gb HS SSD |
4XB7A82265 | BQ1V | ThinkSystem 7mm 5400 PRO 480GB Read Intensive SATA 6Gb HS SSD |
4XB7A82266 | BQ1W | ThinkSystem 7mm 5400 PRO 960GB Read Intensive SATA 6Gb HS SSD |
4XB7A82267 | BR13 | ThinkSystem 7mm 5400 PRO 1.92TB Read Intensive SATA 6Gb HS SSD |
4XB7A82268 | BR12 | ThinkSystem 7mm 5400 PRO 3.84TB Read Intensive SATA 6Gb HS SSD |
4XB7A82269 | BR11 | ThinkSystem 7mm 5400 PRO 7.68TB Read Intensive SATA 6Gb HS SSD |
7mm 2.5-inch hot-swap PCIe 4.0 NVMe SSDs | ||
4XB7A82851 | BS45 | ThinkSystem 7mm U.3 7450 MAX 800GB Mixed Use NVMe PCIe 4.0 x4 HS SSD |
4XB7A82853 | BPZ4 | ThinkSystem 7mm U.3 7450 PRO 960GB Read Intensive NVMe PCIe 4.0 x4 HS SSD |
4XB7A82855 | BPZ5 | ThinkSystem 7mm U.3 7450 PRO 1.92TB Read Intensive NVMe PCIe 4.0 x4 HS SSD |
4XB7A82856 | BPZ6 | ThinkSystem 7mm U.3 7450 PRO 3.84TB Read Intensive NVMe PCIe 4.0 x4 HS SSD |
15mm 2.5-inch hot-swap PCIe 4.0 NVMe SSDs | ||
4XB7A13941 | BMGD | ThinkSystem 2.5" U.2 P5520 1.92TB Read Intensive NVMe PCIe 4.0 x4 HS SSD |
4XB7A13942 | BMGE | ThinkSystem 2.5" U.2 P5520 3.84TB Read Intensive NVMe PCIe 4.0 x4 HS SSD |
4XB7A13943 | BNEF | ThinkSystem 2.5" U.2 P5520 7.68TB Read Intensive NVMe PCIe 4.0 x4 HS SSD |
4XB7A17129 | BNEG | ThinkSystem 2.5" U.2 P5620 1.6TB Mixed Use NVMe PCIe 4.0 x4 HS SSD |
4XB7A17130 | BNEH | ThinkSystem 2.5" U.2 P5620 3.2TB Mixed Use NVMe PCIe 4.0 x4 HS SSD |
4XB7A17160 | BMM8 | ThinkSystem 2.5" U.2 P5800X 1.6TB Write Intensive NVMe PCIe 4.0 x4 HS SSD |
4XB7A13967 | BNEJ | ThinkSystem 2.5" U.3 7450 MAX 1.6TB Mixed Use NVMe PCIe 4.0 x4 HS SSD |
4XB7A13970 | BNEY | ThinkSystem 2.5" U.3 7450 MAX 3.2TB Mixed Use NVMe PCIe 4.0 x4 HS SSD |
4XB7A79647 | BNF2 | ThinkSystem 2.5" U.3 7450 PRO 1.92TB Read Intensive NVMe PCIe 4.0 x4 HS SSD |
4XB7A79648 | BNF5 | ThinkSystem 2.5" U.3 7450 PRO 3.84TB Read Intensive NVMe PCIe 4.0 x4 HS SSD |
4XB7A79649 | BNF4 | ThinkSystem 2.5" U.3 7450 PRO 7.68TB Read Intensive NVMe PCIe 4.0 x4 HS SSD |
2280 NVMe M.2 drives | ||
4XB7A82674 | BQUJ | ThinkSystem M.2 7450 PRO 960GB Read Intensive NVMe PCIe 4.0 x4 NHS SSD (with Heatsink) |
4XB7A83139 | BS46 | ThinkSystem M.2 7450 PRO 480GB Read Intensive NVMe PCIe 4.0 x4 NHS SSD (with Heatsink) |
Optical drive
The server supports the external USB optical drive listed in the following table.
Part number | Feature code | Description |
---|---|---|
7XA7A05926 | AVV8 | ThinkSystem External USB DVD RW Optical Disk Drive |
The drive is based on the Lenovo Slim DVD Burner DB65 drive and supports the following formats: DVD-RAM, DVD-RW, DVD+RW, DVD+R, DVD-R, DVD-ROM, DVD-R DL, CD-RW, CD-R, CD-ROM.
Network Modules
The network ports on the front of the SE350 V2 are provided by a Network Module, a board that plugs into the system board by a dedicated connector. See the Internal view for the location of the connector. The Network Modules are listed in the following table.
Part number | Feature code | Description |
---|---|---|
CTO only | BS3U |
SE350 V2 1Gbx4 I/O Module board |
CTO only | BS3T |
SE350 V2 25G/10G IO Module board |
The Network Modules have the following characteristics:
- 1GbE I/O module board
- Two USB 3.2 Gen 1 Type-A connectors
- USB 3.2 Gen 1 Type-C connector (supporting display)
- USB 2.0 Gen 1 Type-C connector with Lenovo XClarity Controller (XCC) management
- One XCC system management port (1GbE RJ-45)
- Four 1GbE RJ-45 connectors
- Two 2.5GbE RJ-45 connectors
- 2.5G RJ45 ports support 1G speed with LED normal behavior
- Note:
- 2.5Gb RJ45 ports support 100Mbps data transfer, but link speed LED keep dark, do not support 10Mbps.
- 1Gb RJ45 port support 100M bps if link peer does not force speed on 100Mbps since Icelake D doesn’t support 100M half-duplex and link LED is always green status, while ACT LED keeps green and wont blinking when transferring data; do not support 10Mbps
- 10/25GbE SFP28 I/O module board
- Two USB 3.2 Gen 1 Type-A connectors
- USB 3.2 Gen 1 Type-C connector (supporting display)
- USB 2.0 Gen 1 Type-C connector with Lenovo XClarity Controller (XCC) management
- One XCC system management port (1GbE RJ-45)
- Four 10/25GbE SFP28 connectors
- Two 2.5GbE RJ-45 connectors
- No support for 10 Mbps / 100 Mbps speeds
Note: When the shipping bracket is installed, the front operator panel is not accessible.
The network modules are shown in the following figure.
Figure 10. Ports of the available Network Modules
The block diagrams of the Network Modules are shown in the System architecture section.
The specifications of the connections in the two Wired Network Modules are as follows:
- Front IO with 25G/10G x4
- Front Op-Panel
- 4x 10Gb/25Gb SFP28 (SFP28 from CPU embedded LAN)
- 2x 2.5Gb RJ45 (RJ45 from intel I226)
- 1x XCC Management Port (dedicate RJ45 Management port for XCC)
- 1x USB Type-C port (USB Management port for XCC)
- 1x USB Type-C port (USB 3.0/2.0 from CPU for display)
- 2x USB Type-A port (USB 3.0/2.0 from CPU)
- Front IO with 1G x4
- Front Op-Panel
- 4x 1Gb RJ45 (RJ45 from CPU embedded LAN)
- 2x 2.5Gb RJ45 (RJ45 from intel I226)
- 1x XCC Management Port (dedicated RJ45 Management port for XCC)
- 1x USB Type-C port (USB Management port for XCC)
- 1x USB Type-C port (USB 3.0/2.0 from CPU for display)
- 2x USB Type-A port (USB 3.0/2.0 from CPU)
The SFP28 ports in the Wired Network Module support the transceivers listed in the following table.
Part number | Feature code | Description |
---|---|---|
10Gb transceivers | ||
4TC7A78615 | BNDR | ThinkSystem Accelink 10G SR SFP+ Ethernet transceiver |
46C3447 | 5053 | SFP+ SR Transceiver |
00MY034 | ATTJ | Lenovo Dual Rate 1G/10GB SFP Transceiver |
25Gb transceivers | ||
4M27A67041 | BFH2 | Lenovo 25Gb SR SFP28 Ethernet Transceiver |
7G17A03537 | AV1B | Lenovo Dual Rate 10G/25G SR SFP28 Transceiver |
The SFP28 ports of the Network Modules support the following fiber optic cables and direct-attach copper (DAC) cables.
Part number | Feature code | Description |
---|---|---|
LC-LC OM3 Fiber Optic Cables (these cables require a 10 GbE SFP+ SR transceiver) | ||
00MN499 | ASR5 | Lenovo 0.5m LC-LC OM3 MMF Cable |
00MN502 | ASR6 | Lenovo 1m LC-LC OM3 MMF Cable |
00MN505 | ASR7 | Lenovo 3m LC-LC OM3 MMF Cable |
00MN508 | ASR8 | Lenovo 5m LC-LC OM3 MMF Cable |
00MN511 | ASR9 | Lenovo 10m LC-LC OM3 MMF Cable |
00MN514 | ASRA | Lenovo 15m LC-LC OM3 MMF Cable |
00MN517 | ASRB | Lenovo 25m LC-LC OM3 MMF Cable |
00MN520 | ASRC | Lenovo 30m LC-LC OM3 MMF Cable |
OM4 LC to LC Cables (these cables require a transceiver) | ||
4Z57A10845 | B2P9 | Lenovo 0.5m LC-LC OM4 MMF Cable |
4Z57A10846 | B2PA | Lenovo 1m LC-LC OM4 MMF Cable |
4Z57A10847 | B2PB | Lenovo 3m LC-LC OM4 MMF Cable |
4Z57A10848 | B2PC | Lenovo 5m LC-LC OM4 MMF Cable |
4Z57A10849 | B2PD | Lenovo 10m LC-LC OM4 MMF Cable |
4Z57A10850 | B2PE | Lenovo 15m LC-LC OM4 MMF Cable |
4Z57A10851 | B2PF | Lenovo 25m LC-LC OM4 MMF Cable |
4Z57A10852 | B2PG | Lenovo 30m LC-LC OM4 MMF Cable |
SFP+ 10Gb Passive DAC Cables | ||
00AY764 | A51N | 1.5m Passive DAC SFP+ Cable |
00AY765 | A51P | 2m Passive DAC SFP+ Cable |
90Y9430 | A1PJ | 3m Passive DAC SFP+ Cable |
25G SFP28 Active Optical Cables | ||
7Z57A03541 | AV1F | Lenovo 3m 25G SFP28 Active Optical Cable |
7Z57A03542 | AV1G | Lenovo 5m 25G SFP28 Active Optical Cable |
7Z57A03543 | AV1H | Lenovo 10m 25G SFP28 Active Optical Cable |
7Z57A03544 | AV1J | Lenovo 15m 25G SFP28 Active Optical Cable |
7Z57A03545 | AV1K | Lenovo 20m 25G SFP28 Active Optical Cable |
100G QSFP28 Breakout Active Optical Cables | ||
7Z57A03551 | AV1R | Lenovo 3m 100G to 4x25G Breakout Active Optical Cable |
7Z57A03552 | AV1S | Lenovo 5m 100G to 4x25G Breakout Active Optical Cable |
7Z57A03553 | AV1T | Lenovo 10m 100G to 4x25G Breakout Active Optical Cable |
7Z57A03554 | AV1U | Lenovo 15m 100G to 4x25G Breakout Active Optical Cable |
7Z57A03555 | AV1V | Lenovo 20m 100G to 4x25G Breakout Active Optical Cable |
The following table lists the direct-attach copper (DAC) cables that are supported in the 25GbE port.
Part number | Feature code | Description |
---|---|---|
SFP+ 10Gb Passive DAC Cables | ||
00D6288 | A3RG | 0.5m Passive DAC SFP+ Cable |
90Y9427 | A1PH | 1m Passive DAC SFP+ Cable |
00AY764 | A51N | 1.5m Passive DAC SFP+ Cable |
00AY765 | A51P | 2m Passive DAC SFP+ Cable |
90Y9430 | A1PJ | 3m Passive DAC SFP+ Cable |
90Y9433 | A1PK | 5m Passive DAC SFP+ Cable |
00D6151 | A3RH | 7m Passive DAC SFP+ Cable |
SFP28 25Gb Passive DAC Cables | ||
7Z57A03557 | AV1W | Lenovo 1m Passive 25G SFP28 DAC Cable |
7Z57A03558 | AV1X | Lenovo 3m Passive 25G SFP28 DAC Cable |
7Z57A03559 | AV1Y | Lenovo 5m Passive 25G SFP28 DAC Cable |
QSFP28 100G-to-4x25G Breakout Cables | ||
7Z57A03564 | AV22 | Lenovo 1m 100G QSFP28 to 4x25G SFP28 Breakout DAC Cable |
7Z57A03565 | AV23 | Lenovo 3m 100G QSFP28 to 4x25G SFP28 Breakout DAC Cable |
7Z57A03566 | AV24 | Lenovo 5m 100G QSFP28 to 4x25G SFP28 Breakout DAC Cable |
The RJ45 ports of the Network Modules support the following Category 6 (CAT 6) cables.
Part number | Feature code | Description |
---|---|---|
CAT6 Green Cables | ||
00WE123 | AVFW | 0.75m CAT6 Green Cable |
00WE127 | AVFX | 1.0m CAT6 Green Cable |
00WE131 | AVFY | 1.25m CAT6 Green Cable |
00WE135 | AVFZ | 1.5m CAT6 Green Cable |
00WE139 | AVG0 | 3m CAT6 Green Cable |
90Y3715 | A1MS | 10m Yellow Cat6 Cable |
90Y3718 | A1MT | 10m Green Cat6 Cable |
90Y3721 | A1MU | 10m Blue Cat6 Cable |
90Y3724 | A1MV | 25m Yellow Cat6 Cable |
90Y3727 | A1MW | 25m Green Cat6 Cable |
90Y3730 | A1MX | 25m Blue Cat6 Cable |
CAT6 RJ45/RJ45 | ||
4X97A83980 | BRW9 | Lenovo 750mm Cat6 RJ45 White Cable without Jacket |
4X97A83981 | BRWA | Lenovo 1000mm Cat6 RJ45 White Cable without Jacket |
4X97A83982 | BRWB | Lenovo 1250mm Cat6 RJ45 White Cable without Jacket |
4X97A83983 | BRWC | Lenovo 1500mm Cat6 RJ45 White Cable without Jacket |
4X97A83984 | BRWD | Lenovo 3000mm Cat6 RJ45 White Cable without Jacket |
Network adapters
The SE350 V2 does not support additional network adapters. There is no PCIe slot available.
GPU adapters
The SE350 V2 does not support any graphics processing units (GPUs). There is no PCIe slot available.
Cooling
The SE350 V2 server has three 40 mm non-hot-swap fans. All three are standard and support N+1 redundancy.
Power supplies
The SE350 V2 supports three type of power input path as following components and options:
- AC Power Cord to external 300W adapter mode (5°C to 40°C)
- Details regarding the use of AC adapters:
- One or two AC adapters are supported.
- When two AC adapters are connected, the second AC adapter is redundant.
- In case of failure of an AC adapter, system will throttle if power budget is above adapter capacity.
- To connect AC Adapters to system directly a bridge cable is required.
- AC Adapters do not include a line cord. See the next section for available power cords.
- Details regarding the use of AC adapters:
- DC using Direct Connection (12-48V) (0°C to 55°C)
- Details regarding the use of DC power:
- One or two DC power input source are supported.
- When two DC power input are connected, the second DC input is redundant.
- In case of failure of DC input, system will throttle if power budget is above DC input capacity.
- DC Terminal block cable for DC power source connection with system.
- Details regarding the use of DC power:
- Pure AC Input Mode (0°C to 55°C)
- Details regarding the use of AC power:
- One AC power input source is supported only.
- Pure AC input do not support power redundant and is non-hot swap.
- Power supply do not include a line cord. See the next section for available power cords.
- Details regarding the use of AC power:
Ordering information is listed in the following table.
Part number | Feature code | Description | Maximum supported |
---|---|---|---|
AC Power Cord to external 300W adapter mode | |||
CTO only | BU98 | ThinkEdge SE350 V2 12-48V DC Power Module Board | 1 |
CTO only | BS4A | ThinkEdge SE350 V2 DC Power Input Board | 1 |
4X27A88607 | BW2K | ThinkEdge 300W 230V/115V External Power Supply | 2 |
4X97A88737 | BW2I | ThinkEdge SE350 V2 External 300W Bridge Cable | 2 |
DC using Direct Connection (12-48V) | |||
CTO only | BU98 | ThinkEdge SE350 V2 12-48V DC Power Module Board | 1 |
CTO only | BS4A | ThinkEdge SE350 V2 DC Power Input Board | 1 |
4L67A91004 | BS4C | ThinkEdge SE350 V2 External DC Terminal Block Cable | 2 |
Pure AC Input Mode | |||
CTO only | BUGP | ThinkEdge SE350 V2 AC Power Input Board | 1 |
CTO only | BWK7 | ThinkEdge SE350 V2 500W 230V/115V Non-Hot Swap Power Supply | 1 |
Power cords
Line cords and rack power cables can be ordered as listed in the following table.
Part number | Feature code | Description |
---|---|---|
Power cord for AC adapters | ||
39Y7930 | 6222 | 2.8m, 10A/250V, C13 to IRAM 2073 (Argentina) Line Cord |
81Y2384 | 6492 | 4.3m 10A/220V, C13 to IRAM 2073 (Argentina) Line Cord |
39Y7924 | 6211 | 2.8m, 10A/250V, C13 to AS/NZ 3112 (Australia/NZ) Line Cord |
81Y2383 | 6574 | 4.3m, 10A/230V, C13 to AS/NZS 3112 (Aus/NZ) Line Cord |
69Y1988 | 6532 | 2.8m, 10A/250V, C13 to NBR 14136 (Brazil) Line Cord |
81Y2387 | 6404 | 4.3m, 10A/250V, C13 - 2P+Gnd (Brazil) Line Cord |
39Y7928 | 6210 | 2.8m, 220-240V, C13 to GB 2099.1 (China) Line Cord |
81Y2378 | 6580 | 4.3m, 10A/220V, C13 to GB 2099.1 (China) Line Cord |
39Y7918 | 6213 | 2.8m, 10A/250V, C13 to DK2-5a (Denmark) Line Cord |
81Y2382 | 6575 | 4.3m, 10A/230V, C13 to DK2-5a (Denmark) Line Cord |
39Y7917 | 6212 | 2.8m, 10A/230V, C13 to CEE7-VII (Europe) Line Cord |
81Y2376 | 6572 | 4.3m, 10A/230V, C13 to CEE7-VII (Europe) Line Cord |
39Y7927 | 6269 | 2.8m, 10A/250V, C13(2P+Gnd) (India) Line Cord |
81Y2386 | 6567 | 4.3m, 10A/240V, C13 to IS 6538 (India) Line Cord |
39Y7920 | 6218 | 2.8m, 10A/250V, C13 to SI 32 (Israel) Line Cord |
81Y2381 | 6579 | 4.3m, 10A/230V, C13 to SI 32 (Israel) Line Cord |
39Y7921 | 6217 | 2.8m, 220-240V, C13 to CEI 23-16 (Italy/Chile) Line Cord |
81Y2380 | 6493 | 4.3m, 10A/230V, C13 to CEI 23-16 (Italy/Chile) Line Cord |
46M2593 | A1RE | 2.8m, 12A/125V, C13 to JIS C-8303 (Japan) Line Cord |
4L67A08357 | 6533 | 2.8m, 200V, C13 to JIS C-8303 (Japan) Line Cord |
39Y7926 | 6335 | 4.3m, 12A/100V, C13 to JIS C-8303 (Japan) Line Cord |
4L67A08362 | 6495 | 4.3m, 12A/200V, C13 to JIS C-8303 (Japan) Line Cord |
39Y7922 | 6214 | 2.8m, 10A/250V, C13 to SABS 164 (S Africa) Line Cord |
81Y2379 | 6576 | 4.3m, 10A/230V, C13 to SABS 164 (South Africa) Line Cord |
39Y7925 | 6219 | 2.8m, 220-240V, C13 to KETI (S Korea) Line Cord |
81Y2385 | 6494 | 4.3m, 12A/220V, C13 to KSC 8305 (S. Korea) Line Cord |
39Y7919 | 6216 | 2.8m, 10A/250V, C13 to SEV 1011-S24507 (Swiss) Line Cord |
81Y2390 | 6578 | 4.3m, 10A/230V, C13 to SEV 1011-S24507 (Sws) Line Cord |
23R7158 | 6386 | 2.8m, 10A/125V, C13 to CNS 10917-3 (Taiwan) Line Cord |
81Y2375 | 6317 | 2.8m, 10A/240V, C13 to CNS 10917-3 (Taiwan) Line Cord |
4L67A08363 | AX8B | 4.3m, 10A 125V, C13 to CNS 10917 (Taiwan) Line Cord |
81Y2389 | 6531 | 4.3m, 10A/250V, C13 to 76 CNS 10917-3 (Taiwan) Line Cord |
39Y7923 | 6215 | 2.8m, 10A/250V, C13 to BS 1363/A (UK) Line Cord |
81Y2377 | 6577 | 4.3m, 10A/230V, C13 to BS 1363/A (UK) Line Cord |
90Y3016 | 6313 | 2.8m, 10A/120V, C13 to NEMA 5-15P (US) Line Cord |
4L67A08359 | 6370 | 4.3m, 10A/125V, C13 to NEMA 5-15P (US) Line Cord |
4L67A08361 | 6373 | 4.3m, 10A/250V, C13 to NEMA 6-15P (US) Line Cord |
46M2592 | A1RF | 2.8m, 10A/250V, C13 to NEMA 6-15P Line Cord |
Rack jumper cables for AC adapters | ||
SL67B08593 | BPHZ | 0.5m, 10A/100-250V, C13 to C14 Jumper Cord |
00Y3043 | A4VP | 1.0m, C13 to C14 Jumper Cord, Rack Power Cable |
4L67A08365 | B0N4 | 2.0m, 10A/100-250V, C13 to C14 Jumper Cord |
4L67A08366 | 6311 | 2.8m, 10A/100-250V, C13 to C14 Jumper Cord |
39Y7937 | 6201 | 1.5m, 10A/100-250V, C13 to IEC 320-C14 Rack Power Cable |
39Y7932 | 6263 | 4.3m, 10A/100-250V, C13 to IEC 320-C14 Rack Power Cable |
Rack Y-type jumper cables for AC adapters | ||
00Y3046 | A4VQ | 1.345m, 2X C13 to C14 Jumper Cord, Rack Power Cable |
00Y3047 | A4VR | 2.054m, 2X C13 to C14 Jumper Cord, Rack Power Cable |
Systems management
The SE350 V2 contains an integrated service processor, XClarity Controller 2 (XCC2), which provides advanced control, monitoring, and alerting functions. The XCC2 is based on the AST2600 baseboard management controller (BMC) using a dual-core ARM Cortex A9 service processor.
Topics in this section:
Local management
The SE350 V2 offers a front operator panel with key LED status indicators, as shown in the following figure.
The buttons on the front of the server:
- Power button
- Identification button - turns on the LED housed within the button as well as passing the signal to the XCC for display remotely in XClarity Administrator
- NMI reset pinhole - sends a NMI signal to the processor thereby causing a blue-screen trap of the operating system
The LEDs on the front of the server are as follows:
- Power LED (green) - indicated activation and power status, as follows:
- Off - Server does not have power applied
- Fast flash (4 times per second) - Either server has just had power applied and is not ready to be powered on yet, or the server has not been activated yet
- Slow flash (once per second) - Server is ready to be powered on
- On solid - Server is powered on
- Identification LED (blue) - lights when the button is pressed or when the function is activated remotely in XClarity Controller.
- Security LED - (green) - indicates system security status.
- Solid on - the server is operating with security enabled
- Blinking - the server is in lockdown mode. Activate or unlock the system for operation or activation. See activate or unlock system.
- Off - No security feature is enabled on the server.
The front of the server also houses an information pull-out tab (also known as the network access tag). See Figure 2 for the location. A label on the tab shows the network information (MAC address and other data) to remotely access the XCC service processor.
The SE350 V2 also supports optional connection to local VGA monitor.
Part number | Feature code | Description |
---|---|---|
4X97A86591 | BS4E | ThinkEdge 130mm USB-C to VGA Display Cable |
System status with XClarity Mobile
The SE350 V2 also supports local systems management using the XClarity Mobile app. The app includes a tethering function where you can connect your Android or iOS device to the server via the micro-USB port on the server.
You will need a mobile device with a supported operating system installed (iOS 12 or later, Android 5.0 or later), plus the USB charging cable that comes with your phone. You will also need the USB type-C to USB type-A cable that ships with the SE350 V2.
The steps to connect the mobile device are as follows:
- Connect the mobile device via your USB cable and the supplied USB-to USB type-C cable to the SE350 V2's USB type-C port with the management symbol
- In iOS or Android settings, enable Personal Hotspot or USB Tethering
- Launch the Lenovo XClarity Mobile app
Once connected you can see the following information:
- Server status including error logs (read only, no login required)
- Server management functions (XClarity login credentials required)
The supported USB cable is listed in the following table.
Part number | Feature code | Description |
---|---|---|
4X97A88620 | BS4D | ThinkEdge USB-C to USB-A Console Cable |
Remote management
The server offers a dedicated RJ45 port at the rear of the server for remote management via the XClarity Controller management processor. The port supports 10/100/1000 Mbps speeds.
Remote server management is provided through industry-standard interfaces:
- Intelligent Platform Management Interface (IPMI) Version 2.0
- Simple Network Management Protocol (SNMP) Version 3 (no SET commands; no SNMP v1)
- Common Information Model (CIM-XML)
- Representational State Transfer (REST) support
- Redfish support (DMTF compliant)
- Web browser - HTML 5-based browser interface (Java and ActiveX not required) using a responsive design (content optimized for device being used - laptop, tablet, phone) with NLS support
The SE350 V2 offers a MicroSD card port on the system board to enable the use of a MicroSD card for additional storage for use with the XCC2 controller. XCC2 can use the storage as a Remote Disc on Card (RDOC) device (up to 32GB of storage). It can also be used to store firmware updates (including N-1 firmware history) for ease of deployment.
Tip: Without a MicroSD card installed, the XCC2 controller will have 100MB of available RDOC storage.
Ordering information for the supported Micro SD card is listed in the following table.
Part number | Feature code | Description |
---|---|---|
4X77A77064 | BNWP | ThinkSystem MicroSD 32GB Class 10 Flash Memory Card |
XCC2 Platinum
The XCC2 service processor in the SE350 V2 supports an upgrade to a Platinum level of features. Compared to the XCC functions of ThinkSystem and earlier systems, Platinum adds the same features as Enterprise and Advanced levels in ThinkSystem, plus additional features.
XCC2 Platinum adds the following Enterprise and Advanced functions:
- Remotely viewing video with graphics resolutions up to 1600x1200 at 75 Hz with up to 23 bits per pixel, regardless of the system state
- Remotely accessing the server using the keyboard and mouse from a remote client
- International keyboard mapping support
- Syslog alerting
- Redirecting serial console via SSH
- Component replacement log (Maintenance History log)
- Access restriction (IP address blocking)
- Lenovo SED security key management
- Displaying graphics for real-time and historical power usage data and temperature
- Boot video capture and crash video capture
- Virtual console collaboration - Ability for up to 6 remote users to be log into the remote session simultaneously
- Remote console Java client
- Mapping the ISO and image files located on the local client as virtual drives for use by the server
- Mounting the remote ISO and image files via HTTPS, SFTP, CIFS, and NFS
- Power capping
- System utilization data and graphic view
- Single sign on with Lenovo XClarity Administrator
- Update firmware from a repository
- License for XClarity Energy Manager
XCC2 Platinum also adds the following features that are new to XCC2:
- System Guard - Monitor hardware inventory for unexpected component changes, and simply log the event or prevent booting
- Enterprise Strict Security mode - Enforces CNSA 1.0 level security
- Neighbor Group - Enables administrators to manage and synchronize configurations and firmware level across multiple servers
Ordering information is listed in the following table. XCC2 Platinum is a software license upgrade - no additional hardware is required.
Part number | Feature code | Description |
---|---|---|
CTO only | BRPJ | XCC Platinum |
With XCC Platinum, for CTO orders, you can request that System Guard be enabled in the factory and the first configuration snapshot be recorded. To add this to an order, select feature code listed in the following table. The selection is made in the Security tab of the DCSC configurator.
Feature code | Description |
---|---|
BUT2 | Install System Guard |
For more information about System Guard, see https://pubs.lenovo.com/xcc2/NN1ia_c_systemguard
Lenovo XClarity Provisioning Manager
Lenovo XClarity Provisioning Manager (LXPM) is a UEFI-based application embedded in ThinkSystem servers and accessible via the F1 key during system boot.
LXPM provides the following functions:
- Graphical UEFI Setup
- System inventory information and VPD update
- System firmware updates (UEFI and XCC)
- RAID setup wizard
- OS installation wizard (including unattended OS installation)
- Diagnostics functions
Lenovo XClarity Administrator
Lenovo XClarity Administrator is a centralized resource management solution designed to reduce complexity, speed response, and enhance the availability of Lenovo systems and solutions. It provides agent-free hardware management for ThinkSystem servers, in addition to ThinkServer, System x, and Flex System servers. The administration dashboard is based on HTML 5 and allows fast location of resources so tasks can be run quickly.
Because Lenovo XClarity Administrator does not require any agent software to be installed on the managed endpoints, there are no CPU cycles spent on agent execution, and no memory is used, which means that up to 1GB of RAM and 1 - 2% CPU usage is saved, compared to a typical managed system where an agent is required.
Lenovo XClarity Administrator is an optional software component for the SE350 V2. The software can be downloaded and used at no charge to discover and monitor the SE350 V2 and to manage firmware upgrades.
If software support is required for Lenovo XClarity Administrator, or premium features such as configuration management and operating system deployment are required, Lenovo XClarity Pro software subscription should be ordered. Lenovo XClarity Pro is licensed on a per managed system basis, that is, each managed Lenovo system requires a license.
The following table lists the Lenovo XClarity software license options.
Part number | Feature code | Description |
---|---|---|
00MT201 | 1339 | Lenovo XClarity Pro, per Managed Endpoint w/1 Yr SW S&S |
00MT202 | 1340 | Lenovo XClarity Pro, per Managed Endpoint w/3 Yr SW S&S |
00MT203 | 1341 | Lenovo XClarity Pro, per Managed Endpoint w/5 Yr SW S&S |
7S0X000HWW | SAYV | Lenovo XClarity Pro, per Managed Endpoint w/6 Yr SW S&S |
7S0X000JWW | SAYW | Lenovo XClarity Pro, per Managed Endpoint w/7 Yr SW S&S |
Lenovo XClarity Administrator offers the following standard features that are available at no charge:
- Auto-discovery and monitoring of Lenovo systems
- Firmware updates and compliance enforcement
- External alerts and notifications via SNMP traps, syslog remote logging, and e-mail
- Secure connections to managed endpoints
- NIST 800-131A or FIPS 140-2 compliant cryptographic standards between the management solution and managed endpoints
- Integration into existing higher-level management systems such as cloud automation and orchestration tools through REST APIs, providing extensive external visibility and control over hardware resources
- An intuitive, easy-to-use GUI
- Scripting with Windows PowerShell, providing command-line visibility and control over hardware resources
Lenovo XClarity Administrator offers the following premium features that require an optional Pro license:
- Pattern-based configuration management that allows to define configurations once and apply repeatedly without errors when deploying new servers or redeploying existing servers without disrupting the fabric
- Bare-metal deployment of operating systems and hypervisors to streamline infrastructure provisioning
For more information, refer to the Lenovo XClarity Administrator Product Guide:
http://lenovopress.com/tips1200
Lenovo XClarity Integrators
Lenovo also offers software plug-in modules, Lenovo XClarity Integrators, to manage physical infrastructure from leading external virtualization management software tools including those from Microsoft and VMware.
These integrators are offered at no charge, however if software support is required, a Lenovo XClarity Pro software subscription license should be ordered.
Lenovo XClarity Integrators offer the following additional features:
- Ability to discover, manage, and monitor Lenovo server hardware from VMware vCenter or Microsoft System Center
- Deployment of firmware updates and configuration patterns to Lenovo x86 rack servers and Flex System from the virtualization management tool
- Non-disruptive server maintenance in clustered environments that reduces workload downtime by dynamically migrating workloads from affected hosts during rolling server updates or reboots
- Greater service level uptime and assurance in clustered environments during unplanned hardware events by dynamically triggering workload migration from impacted hosts when impending hardware failures are predicted
For more information about all the available Lenovo XClarity Integrators, see the Lenovo XClarity Administrator Product Guide: https://lenovopress.com/tips1200-lenovo-xclarity-administrator
Lenovo XClarity Essentials
Lenovo offers the following XClarity Essentials software tools that can help you set up, use, and maintain the server at no additional cost:
- Lenovo Essentials OneCLI
OneCLI is a collection of server management tools that uses a command line interface program to manage firmware, hardware, and operating systems. It provides functions to collect full system health information (including health status), configure system settings, and update system firmware and drivers.
- Lenovo Essentials UpdateXpress
The UpdateXpress tool is a standalone GUI application for firmware and device driver updates that enables you to maintain your server firmware and device drivers up-to-date and help you avoid unnecessary server outages. The tool acquires and deploys individual updates and UpdateXpress System Packs (UXSPs) which are integration-tested bundles.
- Lenovo Essentials Bootable Media Creator
The Bootable Media Creator (BOMC) tool is used to create bootable media for offline firmware update.
For more information and downloads, visit the Lenovo XClarity Essentials web page:
http://support.lenovo.com/us/en/documents/LNVO-center
Lenovo XClarity Energy Manager
Lenovo XClarity Energy Manager (LXEM) is a power and temperature management solution for data centers. It is an agent-free, web-based console that enables you to monitor and manage power consumption and temperature in your data center through the management console. It enables server density and data center capacity to be increased through the use of power capping.
LXEM is a licensed product. A single-node LXEM license is included with the XClarity Controller Enterprise upgrade as described in the Remote Management section. If your server does not have the XCC Enterprise upgrade, Energy Manager licenses can be ordered as shown in the following table.
Part number | Description |
---|---|
4L40E51621 | Lenovo XClarity Energy Manager Node License (1 license needed per server) |
For more information about XClarity Energy Manager, see the following resources:
- Lenovo Support page:
https://datacentersupport.lenovo.com/us/en/solutions/lnvo-lxem - Lenovo Information Center:
https://sysmgt.lenovofiles.com/help/topic/LXEM/lxem_overview.html?cp=4
Lenovo Capacity Planner
Lenovo Capacity Planner is a power consumption evaluation tool that enhances data center planning by enabling IT administrators and pre-sales professionals to understand various power characteristics of racks, servers, and other devices. Capacity Planner can dynamically calculate the power consumption, current, British Thermal Unit (BTU), and volt-ampere (VA) rating at the rack level, improving the planning efficiency for large scale deployments.
For more information, refer to the Capacity Planner web page:
http://datacentersupport.lenovo.com/us/en/solutions/lnvo-lcp
Security
The SE350 V2 offers a number of security features, both electronic and physical.
Figure 12. Security features of the SE350 V2
Physical security features:
- Support for a Kensington lock and cable
The server has a slot on the side of the server which a customer-supplied Kensington lock and cable can be attached to, to help prevent theft of the server.
- Intrusion arm/disarm feature
The Kensington cable slot can also double as an electronic switch to disarm the intrusion switch detection, so that authorized servicing of the hardware can be performed without triggering the security actions. Available as the Anti-Tampering Keylock Kit, CTO only. The kit includes a Kensington lock (without cable) that is attached to the outside of the server.
Note: This intrusion arm/disarm feature is not supported with the 1U or 2U rack enclosure mounting options, due to physical restrictions with the Kensington lock.
- Front bezel with key lock
Optional component that mounts on the front of the server that restricts access to networking connectors on the front of the server. See "mounting options" section for more information.
Electronic security features include:
- Self-encrypting (SED) on M.2 and 2.5" SSD drives that ensure data is secured when the drives are powered off
- Administrator password and a power-on password in UEFI
- Onboard Trusted Platform Module (TPM) supporting TPM 2.0 enables advanced cryptographic functionality in the operating system and applications.
- For China users, the server has an internal TCM port that supports a Nationz TPM 2.0 module. Available CTO only.
The server is NIST SP 800-147B compliant.
Ordering information for the security components is listed in the following table.
Part number | Feature code | Description |
---|---|---|
4XF7A88717 | BS4J |
ThinkEdge SE350 V2 Anti-Tampering Keylock Kit
|
CTO only | B8LE | ThinkSystem NationZ TPM 2.0 for PRC |
System Lockdown Mode
System Lockdown Mode is an optional security feature of the SE350 V2 that ensures that the system is only used by its intended recipient and that all data and applications remains secure.
System Lockdown Mode is an optional feature that can be remotely managed in two ways:
- ThinkShield Key Vault Portal Managed. This provides a centralised remote management approach, allowing the administrator to remotely managed multiple systems and to register ownership of systems to their company, which reduces the system’s value is stolen.
- XClarity Controller Managed. This provides remote management level control to an individual system using XCC web interface, OneCLI or Redfish.
To select ThinkShield Key Vault Portal Managed in factory orders, select feature BYBR, as listed in the following table. The default in DCSC is to select XClarity Controller Managed, feature BYBQ.
Feature code | Description | Purpose |
---|---|---|
BYBR | ThinkShield Key Vault Portal Managed | System Lockdown Mode is enabled in the factory (Activation required on delivery). The server remains secured and in System Lockdown Mode until registered and activated with the ThinkEdge Key Vault Portal. Unauthorized tampering of the server will result in the server being locked down and the data secured, and will remain in this state until reauthenticated with the Key Vault Portal. |
BYBQ | XClarity Controller Managed | Default choice in DCSC. System Lockdown Mode is not enabled in the factory. Configures the server security to be managed by the XCC2 management processor. Server will boot at first power on and, by default, will not be locked down on any tamper event. You can configure tamper detection in the XCC2 interface if desired. The server can be converted to be managed ThinkShield Key Vault Portal at a later stage if desired (one-way conversion). |
If System Lockdown is enabled in the factory, the system will be delivered in system lockdown mode and will require activation before operation. There are three ways the server can be activated:
- Using a mobile device (iOS or Android) connect to the server to the USB management port on the front of the server and running the ThinkShield Edge Mobile Management app.
- Connecting the system to the Internet via the XCC management port on the front of the server and accessing the ThinkShield Key Vault Portal from a web browser on another system.
- In a disconnected mode, where neither a mobile device or an internet connection to the SE350 V2 are available.
For more information, see ThinkEdge Security, available from:
https://lenovopress.lenovo.com/lp1725-thinkedge-security
Converting from XCC Managed to Portal Managed: It is possible to convert a system from XCC Managed security to ThinkShield Key Vault Portal Managed via the XCC management interface, however the reverse is not possible. Once a server is in ThinkShield Key Vault Portal Managed mode, it cannot be converted back to XClarity Controller Managed.
The SE350 V2 offers a Security LED that indicates the status of the server:
- LED on: Security is enabled; System is operational.
- LED blinking: Security is enabled and the server is in lockdown, either due to being delivered from the factory in lockdown mode or has entered lockdown as a result of a tamper event. System must be activated or reactivated before becoming operational.
- LED off: Security is disabled; System is operational.
SED encryption in factory orders
The SE350 V2 also optionally supports enabling SED drive encryption in the factory using feature BYBS as listed in the following table. This feature enables SED on the selected drives and sets and SED Authentication Key (SED AK).
Tip: SED encryption is a function that is independent of System Lockdown Control.
Feature code | Description | Purpose |
---|---|---|
BYBS | SED Enabled | Enables SED drive encryption on all factory installed drives and sets an SED Authentication Key (AK). |
System Guard
The System Guard feature takes a snapshot of the hardware component inventory as trusted reference, then monitors for any deviation from the reference snapshot.
When deviation occurs, it can report an event to the user, optionally, can also prevent the server from booting into the OS and prompt the user for response.
- System Guard is only enabled with XCC2 on V3 code
- Server supports this feature (BUT2) when XCC Platinum enabled only.
- The System Guard feature is disabled by default
System Guard is a feature of XCC Platinum. Sytem Guard (BUT2) should only be selectable if XCC Platinum (BRPJ) is selected.
Feature code | Description |
---|---|
BRPJ | XCC Platinum |
BUT2 | Enable System Guard |
Platform Firmware Resiliency - Lenovo ThinkShield
Lenovo's ThinkShield Security is a transparent and comprehensive approach to security that extends to all dimensions of our data center products: from development, to supply chain, and through the entire product lifecycle.
The includes Platform Firmware Resiliency (PFR) hardware Root of Trust (RoT) which enables the system to be NIST SP800-193 compliant. This offering further enhances key platform subsystem protections against unauthorized firmware updates and corruption, to restore firmware to an integral state, and to closely monitor firmware for possible compromise from cyber attacks.
PFR operates upon the following server components:
- UEFI image – the low-level server firmware that connects the operating system to the server hardware
- XCC image – the management “engine” software that controls and reports on the server status separate from the server operating system
- FPGA image – the code that runs the server’s lowest level hardware controller on the motherboard
The Lenovo Platform Root of Trust Hardware performs the following three main functions:
- Detection – Measures the firmware and updates for authenticity
- Recovery – Recovers a corrupted image to a known-safe image
- Protection – Monitors the system to ensure the known-good firmware is not maliciously written
These enhanced protection capabilities are implemented using a dedicated, discrete security processor whose implementation has been rigorously validated by leading third-party security firms. Security evaluation results and design details are available for customer review – providing unprecedented transparency and assurance.
The SE350 V2 includes support for Secure Boot, a UEFI firmware security feature developed by the UEFI Consortium that ensures only immutable and signed software are loaded during the boot time. The use of Secure Boot helps prevent malicious code from being loaded and helps prevent attacks, such as the installation of rootkits. Lenovo offers the capability to enable secure boot in the factory, to ensure end-to-end protection. Alternatively, Secure Boot can be left disabled in the factory, allowing the customer to enable it themselves at a later point, if desired.
The following table lists the relevant feature code(s).
Part number | Feature code | Description | Purpose |
---|---|---|---|
CTO only | AUK7 | TPM 2.0 and Secure Boot | Configure the system in the factory with Secure Boot enabled. |
CTO only | B0MK | Enable TPM 2.0 | Configure the system without Secure Boot enabled. Customers can enable Secure Boot later if desired. |
Tip: If Secure Boot is not enabled in the factory, it can be enabled later by the customer. However once Secure Boot is enabled, it cannot be disabled.
Intel Transparent Supply Chain
Add a layer of protection in your data center and have peace of mind that the server hardware you bring into it is safe authentic and with documented, testable, and provable origin.
Lenovo has one of the world’s best supply chains, as ranked by Gartner Group, backed by extensive and mature supply chain security programs that exceed industry norms and US Government standards. Now we are the first Tier 1 manufacturer to offer Intel® Transparent Supply Chain in partnership with Intel, offering you an unprecedented degree of supply chain transparency and assurance.
To enable Intel Transparent Supply Chain for the Intel-based servers in your order, add the following feature code in the DCSC configurator, under the Security tab.
Feature code | Description |
---|---|
BB0P | Intel Transparent Supply Chain |
For more information on this offering, see the paper Introduction to Intel Transparent Supply Chain on Lenovo ThinkSystem Servers, available from https://lenovopress.com/lp1434-introduction-to-intel-transparent-supply-chain-on-thinksystem-servers.
Mounting options
The SE350 V2 is designed to be used in a variety of locations -- wall, ceiling, DIN-rail, table top -- as well as in a rack mount.
In this section:
Mounting components
Many of the mounting options share the same components.
Node sleeve
The node sleeve, shown below, holds the SE350 V2 server when mounted on the wall or connected to DIN rail. The server is then slid into the node sleeve and secured with additional thumbscrews.
Figure 13. Node sleeve image
Part number | Feature code | Description | Quantity required |
---|---|---|---|
4M17A37607 | B6EZ | ThinkEdge Node Sleeve (VESA mount) | 1 per server |
Desktop mount
Desktop mounting has the server oriented horizontally with self-adhesive rubber pads mounted to its underside.
Figure 14. SE350 V2 with Rubber Feet option
Part number | Feature code | Description | Quantity required |
---|---|---|---|
4M17A37610 | B6Q3 | ThinkEdge Rubber Feet (contains 4 rubber pads) |
1 |
Wall or DIN mount
When wall, ceiling or DIN mounted, the server must be installed onto a sleeve first. For DIN mount, the optional DIN mount kit is required. Server also supports security bezel placement on the front of the node sleeve to help prevent physical access to the front components.
SE350 V2 supports two types of security bezels for each of the two I/O module boards. Bezels include:
- A lock-and-key mechanism for security also support dust filter with optional (4XF7A86284).
- Filter cover the backplane area for SSD and the network area to reduce the dust that can enter the server through the front air holes.
- Security bezel can prevent LAN cable plug or unplug after installed on node sleeve.
Tip: 300W external adapter not supported in Wall / DIN mounting
Part number | Feature code | Description | Quantity required |
---|---|---|---|
Wall mount mode | |||
4M17A37607 | B6EZ | ThinkEdge Node Sleeve | 1 per server |
DIN Rail mount mode | |||
4M17A37607 | B6EZ | ThinkEdge Node Sleeve | 1 per server |
4M17A37285 | B87S | ThinkEdge DIN Mount Kit (Extreme Shock & Vibe) | Optional, for DIN rail only, 1 per server |
Secuirty Bezel | |||
4B37A86282 | BS4F | ThinkEdge SE350 V2 Security Bezel for 10/25GbE I/O Module | Optional, 1 per server |
4B37A86283 | BS4G | ThinkEdge SE350 V2 Security Bezel for 1GbE I/O Module | Optional, 1 per server |
4XF7A86284 | BS4H | ThinkEdge SE350 V2 Security Bezel Dust Filter | Optional, 1 per server |
The DIN Rail Kit contains two brackets, as shown in the following figure.
Locking bezel
The locking bezel is an optional component that mounts on the front of the node sleeve to help prevent physical access to the front components of the server. The bezel includes a lock-and-key mechanism for security. The bezel covers the front slots area and the network area to reduce the dust that can enter the server through the front air holes.
Tip: The use of the locking bezel requires a node sleeve.
Figure 16. Locking Bezel
1U rack installation
Two SE350 V2 servers can be mounted in a 1U space, in a rack server. The components are mounted in the Lenovo ThinkEdge SE350 V2 1U2N Enclosure.
ThinkEdge SE350 V2 1U2N Enclosure have two different enclosure to support three type of power input path. Make sure enclosure and server selection leverage the same power input path for installation.
Notes:
- Lenovo ThinkEdge SE350 V2 1U2N Enclosure is available in DCSC using CTO base model 7DBKCTO1WW
The following figure shows two SE350 V2 servers installed in the 1U2N Enclosure.
Figure 17. Lenovo ThinkEdge SE350 V2 1U2N Enclosure with external adapter
The following figure shows the components used in the 1U rack installation.
Figure 18. Lenovo ThinkEdge SE350 V2 1U2N Enclosure with external adapter components
The following figure shows the 1U short rack.
Figure 19. Lenovo ThinkEdge SE350 V2 1U2N Enclosure with Pure AC Input and DC direct
The following table lists the components used in the 1U rack installation.
Tip: The top cover of the SE350 V2 is removed before installing the server in the enclosure.
Part number | Feature code | Description | Quantity required |
---|---|---|---|
Toolless Slide Rail Kit and CMA | |||
CTO/model only* | 7DBK AVAX | CMA (1U) | 1 per Enclosure |
4M17A11683 | 7DBK AVAL | 1U and 2U Slide Rail | 1 per Enclosure |
4XF7A83645 | 7DBK BS30 | ThinkSystem Enclosure Universal Short Rack Rail Kit | 1 per Enclosure |
4M17A37105 | 7DBK B6H2 | ThinkSystem Friction 2-Post Screw-in Rail Kit | 1 per Enclosure |
1U2N Enclosure components | |||
CTO/model only* | 7DBK BSMC | ThinkEdge SE350 V2 1U2N Enclosure (DC or External PSU) | 1 per Enclosure |
CTO/model only* | 7DBK BVGY | ThinkEdge SE350 V2 1U2N Enclosure (AC) | 1 per Enclosure |
CTO/model only* | 7DBK B6EE | ThinkEdge Enclosure AC Adapter Support Bracket | 1 per Enclosure |
CTO/model only* | 7DBK BSML | ThinkEdge SE350 V2 Enclosure Shipping Bracket | 1 per Enclosure |
4XF7A86286 | 7DBK BSMD | ThinkEdge SE350 V2 Enclosure - Rack Dust Filter | 1 for each server |
* Available via configure-to-order (CTO)
The following figure shows the components included in the Front Shipping Bracket.
Figure 20. 1U2N Enclosure Front Shipping Bracket
The following table summarizes the specifications of the two available rail kits
Feature | Slide Rail Kit |
---|---|
Part number | 4M17A11683 |
CMA | Optional, CTO/model only* (7DBK AVAX) |
Rail length | 807 mm (31.8 in.) |
Rail type | Full-out slide (ball bearing) |
Slide travel | 810 mm (31.9 in.) |
Tool-less installation | Yes |
In-rack server maintenance | Yes |
1U PDU support | Yes |
0U PDU support | Yes |
Rack type | IBM and Lenovo 4-post, IEC standard-compliant |
Mounting holes | Square or round |
Mounting flange thickness | 2 mm (0.08 in.) – 3.3 mm (0.13 in.) |
Max distance between front and rear mounting flanges |
864 mm (34.0 in.) |
* Available via configure-to-order (CTO)
Short-depth 2U rack installation
Two SE350 V2 servers and the four companion AC Adapter power supplies can also be mounted in a short-depth rack or a 2-post rack. In such a configuration, the servers occupy 2U of rack space, the two servers in 1U and the AC Adapters mounted in the 1U space above. The components are mounted in the Lenovo ThinkEdge SE350 V2 2U2N Enclosure, machine type 7DBK.
Note: 2U2N enclosure supports SE350 V2 server and external 300W PSU adapter only.
Notes:
- Lenovo ThinkEdge SE350 V2 2U2N Enclosure is available in DCSC using CTO base model 7DBKCTO2WW
The following figure shows two SE350 V2 servers installed in the Lenovo ThinkEdge SE350 V2 2U2N Enclosure.
Figure 21. Lenovo ThinkEdge SE350 V2 2U2N Enclosure components (rail in open position)
The following table lists the components used in the 1U rack installation.
Tip: The top cover of the SE350 V2 is removed before installing the server in the enclosure.
Part number | Feature code | Description | Quantity required |
---|---|---|---|
Rail kit selections (choose 1) | |||
4M17A37105 | 7DBK B6H2 | ThinkSystem Friction 2-Post Screw-in Rail Kit | 1 per enclosure |
4XF7A83645 | 7DBK BS30 | ThinkSystem Enclosure Universal Short Rack Rail Kit | 1 per enclosure |
2U2N Enclosure components | |||
CTO/model only* | 7DBK BY35 | ThinkEdge SE350 V2 2U2N Enclosure (External PSU) | 1 per Enclosure |
CTO/model only* | 7DBK B6EE | ThinkSystem Enclosure AC Adapter Support Bracket | 1 per Enclosure |
CTO/model only* | 7DBK BSML | ThinkEdge SE350 V2 Enclosure Shipping Bracket | 1 per Enclosure |
4XF7A86286 | 7DBK BSMD | ThinkEdge SE350 V2 Enclosure - Rack Dust Filter | 1 for each server |
* Available via configure-to-order (CTO)
The following figure shows the components included in the Front Shipping Bracket.
Figure 22. ThinkEdge SE350 V2 Enclosure Shipping Bracket
The following table summarizes the specifications of the two available rail kits
Feature | Short Rack Rail Kit | 2-Post Screw-in Rail Kit |
---|---|---|
Part number | 4XF7A83645 | 4M17A37105 |
CMA | None | None |
Rail length | 484 mm (19.1 in.) | 484 mm (19.1 in.) |
Rail type | Half-out slide (friction) | Half-out slide (friction) |
Slide travel | 270 mm (10.6 in.) | 270 mm (10.6 in.) |
Tool-less installation | Yes | No |
In-rack server maintenance | No | No |
1U PDU support | Yes | Yes |
0U PDU support | Yes | Not applicable |
Rack type | 14-inch to 24-inch depth | 2-post, EIA standard-compliant (3-inch to 8-inch) |
Mounting holes | Square, round, or threaded | Square, round, or threaded |
Mounting flange thickness | 2 mm (0.08 in.) – 3.3 mm (0.13 in.) | 2 mm (0.08 in.) – 3.3 mm (0.13 in.) |
Max distance between front and rear mounting flanges |
609 mm (24 in.) | Not applicable |
For additional information on rack mount installation, see the Configuration Installation Guide:
https://pubs.labs.lenovo.com/se350-v2/rack_config?_highlight=mount
Mounting options and power
The following table list supported mounting options and their corresponding supported power type.
Power type / PSU | Desktop | DIN rail (wall/ceiling) | Rack 1U2N | Rack 2U2N |
---|---|---|---|---|
AC & 300W external | Yes | No | Yes | Yes |
DC only | Yes | Yes | Yes | No |
AC only | Yes | Yes | Yes | No |
Operating system support
The SE350 V2 supports the following operating systems:
- Microsoft Windows Server 2019
- Microsoft Windows Server 2022
- Red Hat Enterprise Linux 8.6
- Red Hat Enterprise Linux 8.8
- Red Hat Enterprise Linux 9.0
- Red Hat Enterprise Linux 9.2
- SUSE Linux Enterprise Server 15 SP4
- SUSE Linux Enterprise Server 15 SP5
- SUSE Linux Enterprise Server 15 Xen SP4
- SUSE Linux Enterprise Server 15 Xen SP5
- Ubuntu 20.04 LTS 64-bit
- Ubuntu 22.04 LTS 64-bit
- VMware ESXi 7.0 U3
- VMware ESXi 8.0 U1
- VMware ESXi 8.0 U2
For a complete list of supported, certified and tested operating systems, plus additional details and links to relevant web sites, see the Operating System Interoperability Guide: https://lenovopress.lenovo.com/osig#support=all
For configure-to-order configurations, the server can be preloaded with VMware ESXi on M.2 cards installed in an M.2 Boot Adapter. Ordering information is listed in the following table.
Part number | Feature code | Description |
---|---|---|
CTO only | BMEY | VMware ESXi 7.0 U3 (Factory Installed) |
CTO only | BQ8S | VMware ESXi 8.0 U1 (Factory Installed) |
CTO only | BYC7 | VMware ESXi 8.0 U2 (Factory Installed) |
Physical and electrical specifications
Dimensions and weight of the SE350 V2 server:
- Height 41.7 mm (1.64 in.)
- Width: 209 mm (8.2 in.)
- Depth: 384 mm (15.12 in.)
- Maximum weight: 3.75 kg (8.3 lb)
Dimensions and weight of the 1U2N Enclosure, with external power adapter (4x AC adapter bracket):
- Height: 43 mm (1.7 in.)
- Width: 439.2 mm (17.3 in.) (from EIA bracket to EIA bracket)
- Depth: 773.1 mm (30.44 in.)
- Maximum (with 2 nodes and 4 external power adapters): 16.88 kg (37.2 lbs)
Dimensions and weight of the 1U2N Enclosure, with internal power supply:
- Height: 43 mm (1.7 in.)
- Width: 439.2 mm (17.3 in.) (from EIA bracket to EIA bracket)
- Depth: 476.1 mm (18.7 in.)
- Maximum (with 2 nodes and internal power supplies):
- DC power input: 9.85 kg (21.67 lbs)
- AC power input: 10.03 kg (22.11 lbs)
Dimensions and weight of the 2U2N Enclosure (with AC adapter bracket):
- Height: 86.9 mm (3.4 in.)
- Width: 439.2 mm (17.3 in.) (from EIA bracket to EIA bracket)
- Depth: 476.1 mm (18.74 in.)
- Maximum (with 2 nodes and 4 external power adapters): 16.92 kg (37.30 lbs)
The shipping dimensions (cardboard packaging) of the SE350 V2 are as follows:
- Width: 338 mm (13.3 inches)
- Height: 179 mm (7.0 inches)
- Depth: 569 mm (22.4 inches)
The shipping dimensions (cardboard packaging) of the SE350 V2 1U Enclosure are as follows:
- Width: 587 mm (23.1 inches)
- Height: 225 mm (8.9 inches)
- Depth: 998 mm (39.3 inches)
Electrical specifications:
- Electrical Input - 20V 300W external adapters
- 100 to 127 (nominal) V AC, 50 Hz or 60 Hz
- 200 to 240 (nominal) V AC, 50 Hz or 60 Hz
- Models with DC/DC power module board (output 12V):
- Dual 12-48V variable DC power source input
- Up to two 300W (230V/115V) external power adapters
- Supported external power adapters:
- ThinkEdge 300W 230V/115V External Power Supply
Operating environment
Summary of the environmental specifications of server. Depending on the model, some features might not be available, or some specifications might not apply.
Topics in this section:
- Acoustical noise emissions
- Ambient temperature management
- Environment
- Shock and vibration
- Particulate contamination
Acoustical noise emissions
The server has the following acoustic noise emissions declaration:
- Sound power level (LWAd):
- Idling:
- Minimum: 4.0 bels
- Typical: 4.0 bels
- Maximum: 4.0 bels
- Operating:
- Minimum: 5.3 bels
- Typical: 5.8 bels
- Maximum: 5.8 bels
- Idling:
- Sound pressure level (LpAm):
- Idling:
- Minimum: 26.0 dBA
- Typical: 26.2 dBA
- Maximum: 26.2 dBA
- Operating:
- Minimum: 39.7 dBA
- Typical: 44.2 dBA
- Maximum: 44.2 dBA
- Idling:
Note:
- These sound levels were measured in controlled acoustical environments according to procedures specified by ISO 7779 and are reported in accordance with ISO 9296.
- The declared acoustic noise levels are based on the following configurations, which may change depending on configurations/conditions.
- Minimum: 1x 65W CPU, 2x 16GB RDIMMs, 1GbEx4 + 2.5GbE I/O module board, 1x NVMe M.2 boot drive, 2x SATA SSDs, DC PMB, SE350 V2 Desktop mount.
- Typical: 1x 80W CPU, 4x 64GB RDIMMs, 25/10GbEx4 + 2.5GbE I/O module board, 2x NVMe M.2 boot drives, 4x NVMe SSDs, DC PMB, SE350 V2 Desktop mount.
- Maximum: 1x 100W CPU, 4x 64GB RDIMMs, 25/10GbEx4 + 2.5GbE I/O module board, 2x NVMe M.2 boot drives, 4x NVMe SSDs, DC PMB, SE350 V2 Desktop mount.
- Government regulations (such as those prescribed by OSHA or European Community Directives) may govern noise level exposure in the workplace and may apply to you and your server installation. The actual sound pressure levels in your installation depend upon a variety of factors, including the number of racks in the installation; the size, materials, and configuration of the room; the noise levels from other equipment; the room ambient temperature, and employee's location in relation to the equipment. Further, compliance with such government regulations depends on a variety of additional factors, including the duration of employees' exposure and whether employees wear hearing protection. Lenovo recommends that you consult with qualified experts in this field to determine whether you are in compliance with the applicable regulations.
Ambient temperature management
Adjust ambient temperature when specific components are installed:
- Keep the ambient temperature to 45°C or lower when one or more NVMe drives are installed. If the ambient temperature is over 45°C, the server will have performance degradation.
- Keep the ambient temperature to 40°C or lower when AC adapters are installed.
- Keep the ambient temperature to 30°C or lower to avoid performance degradation when choosing the rack mount with the SE350 V2 1U2N Enclosure. It is advised that the ambient temperature should be kept under 27°C when AC adapters are installed.
For CTO orders, specify the operational temperature requirement and the shock & vibration requirement, by selecting the feature codes listed in the following table. Selecting the higher temperature and shock/vibration values will ensure the correct heat/vibration tolerant components are selected.
Feature code | Description |
---|---|
Operational temperature selections | |
BW2H | System Operational Temperature 5C to 40C / 41F to 104F |
B8ZU | System Operational Temperature 0C to 55C / 32F to 131F |
Environment
ThinkEdge SE350 V2 complies with ASHRAE Class A4 specifications. System performance may be impacted when operating temperature is outside AHSARE A4 specification or fan failed condition over 30°C ambient temperature. ThinkEdge SE350 V2 is supported in the following environment:
- Air temperature:
- Operating
- ASHRAE Class H1: 5°C to 25°C (41°F to 77°F); the maximum ambient temperature decreases by 1°C for every 500 m (1640 ft) increase in altitude above 900 m (2,953 ft).
- ASHRAE Class A2: 10°C to 35°C (50°F to 95°F); the maximum ambient temperature decreases by 1°C for every 300 m (984 ft) increase in altitude above 900 m (2,953 ft).
- ASHRAE Class A3: 5°C to 40°C (41°F to 104°F); the maximum ambient temperature decreases by 1°C for every 175 m (574 ft) increase in altitude above 900 m (2,953 ft).
- ASHRAE Class A4: 5°C to 45°C (41°F to 113°F); the maximum ambient temperature decreases by 1°C for every 125 m (410 ft) increase in altitude above 900 m (2,953 ft).
- The ambient temperature can be extended to 0°C to 55°C (32°F to 131°F) with the following restrictions of configuration:
- No AC adapter installed
- NVMe drives may have performance degradation
- Server off: 0°C to 55°C (32°F to 131°F)
- Shipping/storage: -40°C to 65°C (-40°F to 149°F)
- Operating
- Maximum altitude: 3,050 m (10,000 ft)
- Relative Humidity (non-condensing):
- Operating: 8% to 90%, maximum dew point : 24°C (75.2°F)
- Shipment/storage: 8% to 90%, maximum dew point : 27°C (80.6°F)
- Non-operating (unpacked) storage can pass the following condition: 5% to 95% at 38.7°C (101.7°F) maximum dry-bulb temperature for 48 hrs.
- Particulate contamination
- Depending on the specific configuration,SE350 V2 supports a dust filter installed at the front of the enclosure. The dust filter has a Minimum Efficiency Rating Value (MERV) of 5, per ASHRAE 52.2-2017 / 80% Average Arrestance per ASHRAE 52.1-1992.
Note: Airborne particulates and reactive gases acting alone or in combination with other environmental factors such as humidity or temperature might pose a risk to the server. For information about the limits for particulates and gases, see Particulate contamination.
Shock and vibration
The following information is a summary of the shock and vibration specifications of the server. Depending on the model, some features might not be available, or some specifications might not apply.
Mounting type | Shock (when the server is in operation) | Shock (when the server is not in operation, such as in shipping) | Vibration (when the server is in operation) | Vibration (when the server is not in operation, such as in shipping) |
---|---|---|---|---|
Desktop mount (standing alone) |
Half-sine wave, 15G 11ms |
Trapezoidal wave, 50G 180 inch/sec |
5-100 Hz, 0.15 Grms, 30 mins |
2-200 Hz, 1.04 Grms, 15 mins |
Rack mount (1U2N and 2U2N) |
Half-sine wave, 15G 3ms |
|
5-500 Hz, 0.21 Grms, 15mins |
2-200Hz, 0.8 Grms, 15mins |
DIN-rail mount | Half-sine wave, 15G 11ms | Not applicable | 5-100 Hz, 0.15 Grms, 30 mins | Not applicable |
Wall mount |
|
Not applicable |
|
Not applicable |
Ceiling mount | Not applicable | Not applicable |
|
Not applicable |
The following table indicates what environmental conditions (ambient temperature) are supported with SSD drives.
Part number | Description | 0°C to 35°C | 36°C to 40°C | 41°C to 45°C | 46°C to 50°C | 51°C to 55°C |
---|---|---|---|---|---|---|
7mm SATA SSD - Intel S4520 | ||||||
4XB7A17106 | ThinkSystem 7mm S4520 240GB Read Intensive SATA 6Gb HS SSD | Yes | Yes | Yes | Yes | Yes |
4XB7A17107 | ThinkSystem 7mm S4520 480GB Read Intensive SATA 6Gb HS SSD | Yes | Yes | Yes | Yes | Yes |
4XB7A17108 | ThinkSystem 7mm S4520 960GB Read Intensive SATA 6Gb HS SSD | Yes | Yes | Yes | Yes | Yes |
4XB7A78622 | ThinkSystem 7mm S4520 1.92TB Read Intensive SATA 6Gb HS SSD | Yes | Yes | Yes | Yes | Yes |
4XB7A78623 | ThinkSystem 7mm S4520 3.84TB Read Intensive SATA 6Gb HS SSD | Yes | Yes | Yes | Yes | Yes |
4XB7A78624 | ThinkSystem 7mm S4520 7.68TB Read Intensive SATA 6Gb HS SSD | Yes | Yes | Yes | Yes | Yes |
7mm SATA SSD - Micron 5400 | ||||||
4XB7A82264 | ThinkSystem 7mm 5400 PRO 240GB Read Intensive SATA 6Gb HS SSD | Yes | Yes | Yes | Yes | Yes |
4XB7A82265 | ThinkSystem 7mm 5400 PRO 480GB Read Intensive SATA 6Gb HS SSD | Yes | Yes | Yes | Yes | Yes |
4XB7A82266 | ThinkSystem 7mm 5400 PRO 960GB Read Intensive SATA 6Gb HS SSD | Yes | Yes | Yes | Yes | Yes |
4XB7A82267 | ThinkSystem 7mm 5400 PRO 1.92TB Read Intensive SATA 6Gb HS SSD | Yes | Yes | Yes | Yes | Yes |
4XB7A82268 | ThinkSystem 7mm 5400 PRO 3.84TB Read Intensive SATA 6Gb HS SSD | Yes | Yes | Yes | Yes | Yes |
4XB7A82269 | ThinkSystem 7mm 5400 PRO 7.68TB Read Intensive SATA 6Gb HS SSD | Yes | Yes | Yes | Yes | Yes |
7mm NVMe SSD - Micron 7450 | ||||||
4XB7A82853 | ThinkSystem 7mm U.3 7450 PRO 960GB Read Intensive NVMe PCIe 4.0 x4 HS SSD | Yes | Yes | Yes | Yes | Yes |
4XB7A82855 | ThinkSystem 7mm U.3 7450 PRO 1.92TB Read Intensive NVMe PCIe 4.0 x4 HS SSD | Yes | Yes | Yes | Yes | Yes |
4XB7A82856 | ThinkSystem 7mm U.3 7450 PRO 3.84TB Read Intensive NVMe PCIe 4.0 x4 HS SSD | Yes | Yes | Yes | Yes | Yes |
4XB7A82851 | ThinkSystem 7mm U.3 7450 MAX 800GB Mixed Use NVMe PCIe 4.0 x4 HS SSD | Yes | Yes | Yes | Yes | Yes |
15mm NVMe SSD - Micron 7450 | ||||||
4XB7A79647 | ThinkSystem 2.5" U.3 7450 PRO 1.92TB Read Intensive NVMe PCIe 4.0 x4 HS SSD | Yes | Yes | Yes | Yes† | Yes† |
4XB7A79648 | ThinkSystem 2.5" U.3 7450 PRO 3.84TB Read Intensive NVMe PCIe 4.0 x4 HS SSD | Yes | Yes | Yes | Yes† | Yes† |
4XB7A79649 | ThinkSystem 2.5" U.3 7450 PRO 7.68TB Read Intensive NVMe PCIe 4.0 x4 HS SSD | Yes | Yes | Yes | Yes† | Yes† |
4XB7A13967 | ThinkSystem 2.5” U.3 7450 MAX 1.6TB Mixed Use NVMe PCIe 4.0 x4 HS SSD | Yes | Yes | Yes | Yes† | Yes† |
4XB7A13970 | ThinkSystem 2.5” U.3 7450 MAX 3.2TB Mixed Use NVMe PCIe 4.0 x4 HS SSD | Yes | Yes | Yes | Yes† | Yes† |
15mm NVMe SSD - Intel P5520/P5620 | ||||||
4XB7A17129 | ThinkSystem 2.5” U.2 P5620 1.6TB Mixed Use Mainstream NVMe PCIe 4.0 x4 HS SSD | Yes | Yes | Yes | Yes† | Yes† |
4XB7A17130 | ThinkSystem 2.5” U.2 P5620 3.2TB Mixed Use Mainstream NVMe PCIe 4.0 x4 HS SSD | Yes | Yes | Yes | Yes† | Yes† |
4XB7A17160 | ThinkSystem 2.5” U.2 P5800X 1.6TB Write Intensive NVMe PCIe 4.0 x4 HS SSD | Yes | Yes | Yes | Yes† | Yes† |
4XB7A13941 | ThinkSystem 2.5” U.2 P5520 1.92TB Read Intensive NVMe PCIe 4.0 x4 HS SSD | Yes | Yes | Yes | Yes† | Yes† |
4XB7A13942 | ThinkSystem 2.5” U.2 P5520 3.84TB Read Intensive NVMe PCIe 4.0 x4 HS SSD | Yes | Yes | Yes | Yes† | Yes† |
4XB7A13943 | ThinkSystem 2.5” U.2 P5520 7.68TB Read Intensive NVMe PCIe 4.0 x4 HS SSD | Yes | Yes | Yes | Yes† | Yes† |
M.2 NVMe SSD - Micron 7450 | ||||||
4XB7A82674 | ThinkSystem M.2 7450 PRO 960GB Read Intensive NVMe PCIe 4.0 x4 NHS SSD (with Heatsink) | Yes | Yes | Yes | Yes | Yes |
4XB7A83139 | ThinkSystem M.2 7450 PRO 480GB Read Intensive NVMe PCIe 4.0 x4 NHS SSD (with Heatsink) | Yes | Yes | Yes | Yes | Yes |
† Performance might slightly decrease with this temperature region
Particulate contamination
Depending on the specific configuration,SE350 V2 supports a dust filter installed at the front of the enclosure. The dust filter has a Minimum Efficiency Rating Value (MERV) of 5, per ASHRAE 52.2-2017 / 80% Average Arrestance per ASHRAE 52.1-1992.
Attention: Airborne particulates (including metal flakes or particles) and reactive gases acting alone or in combination with other environmental factors such as humidity or temperature might pose a risk to the device that is described in this document.
Risks that are posed by the presence of excessive particulate levels or concentrations of harmful gases include damage that might cause the device to malfunction or cease functioning altogether. This specification sets forth limits for particulates and gases that are intended to avoid such damage. The limits must not be viewed or used as definitive limits, because numerous other factors, such as temperature or moisture content of the air, can influence the impact of particulates or environmental corrosives and gaseous contaminant transfer. In the absence of specific limits that are set forth in this document, you must implement practices that maintain particulate and gas levels that are consistent with the protection of human health and safety. If Lenovo determines that the levels of particulates or gases in your environment have caused damage to the device, Lenovo may condition provision of repair or replacement of devices or parts on implementation of appropriate remedial measures to mitigate such environmental contamination. Implementation of such remedial measures is a customer responsibility.
Contaminant | Limits |
---|---|
Reactive gases |
Severity level G1 as per ANSI/ISA 71.04-19851:
|
Airborne particulates |
Data centers must meet the cleanliness level of ISO 14644-1 class 8. For data centers without airside economizer, the ISO 14644-1 class 8 cleanliness might be met by choosing one of the following filtration methods:
For data centers with airside economizers, the choice of filters to achieve ISO class 8 cleanliness depends on the specific conditions present at that data center.
|
Notes:
1ANSI/ISA-71.04-1985.Environmental conditions for process measurement and control systems: Airborne contaminants. Instrument Society of America, Research Triangle Park, North Carolina, U.S.A.
2The derivation of the equivalence between the rate of copper corrosion growth in the thickness of the corrosion product in Å/month and the rate of weight gain assumes that Cu2S and Cu2O grow in equal proportions
.3The derivation of the equivalence between the rate of silver corrosion growth in the thickness of the corrosion product in Å/month and the rate of weight gain assumes that Ag2S is the only corrosion product.
4The deliquescent relative humidity of particulate contamination is the relative humidity at which the dust absorbs enough water to become wet and promote ionic conduction.
5Surface debris is randomly collected from 10 areas of the data center on a 1.5 cm diameter disk of sticky electrically conductive tape on a metal stub. If examination of the sticky tape in a scanning electron microscope reveals no zinc whiskers, the data center is considered free of zinc whiskers.
Feature code | Description |
---|---|
Operational temperature selections | |
B8ZU | System Operational Temperature 0C to 55C / 32F to 131F |
Warranty and Support
The ThinkEdge SE350 V2 has 3-year warranty based on the machine type of the system:
- 7DA9 - 3 year warranty
ThinkEdge SE350 V2 1U2N Enclosure Lenovo and ThinkEdge SE350 V2 2U2N Enclosure have the following warranty:
- 7DBK - 3 year warranty
The standard warranty terms are customer-replaceable unit (CRU) and onsite (for field-replaceable units FRUs only) with standard call center support during normal business hours and 9x5 Next Business Day Parts Delivered.
Lenovo’s additional support services provide a sophisticated, unified support structure for your data center, with an experience consistently ranked number one in customer satisfaction worldwide. Available offerings include:
- Premier Support
Premier Support provides a Lenovo-owned customer experience and delivers direct access to technicians skilled in hardware, software, and advanced troubleshooting, in addition to the following:
- Direct technician-to-technician access through a dedicated phone line
- 24x7x365 remote support
- Single point of contact service
- End to end case management
- Third-party collaborative software support
- Online case tools and live chat support
- On-demand remote system analysis
- Warranty Upgrade (Preconfigured Support)
Services are available to meet the on-site response time targets that match the criticality of your systems.
- 3, 4, or 5 years of service coverage
- 1-year or 2-year post-warranty extensions
- Foundation Service: 9x5 service coverage with next business day onsite response. YourDrive YourData is an optional extra (see below).
- Essential Service: 24x7 service coverage with 4-hour onsite response or 24-hour committed repair (available only in select markets). Bundled with YourDrive YourData.
- Advanced Service: 24x7 service coverage with 2-hour onsite response or 6-hour committed repair (available only in select markets). Bundled with YourDrive YourData.
- Managed Services
Lenovo Managed Services provides continuous 24x7 remote monitoring (plus 24x7 call center availability) and proactive management of your data center using state-of-the-art tools, systems, and practices by a team of highly skilled and experienced Lenovo services professionals.
Quarterly reviews check error logs, verify firmware & OS device driver levels, and software as needed. We’ll also maintain records of latest patches, critical updates, and firmware levels, to ensure you systems are providing business value through optimized performance.
- Technical Account Management (TAM)
A Lenovo Technical Account Manager helps you optimize the operation of your data center based on a deep understanding of your business. You gain direct access to your Lenovo TAM, who serves as your single point of contact to expedite service requests, provide status updates, and furnish reports to track incidents over time. In addition, your TAM will help proactively make service recommendations and manage your service relationship with Lenovo to make certain your needs are met.
- Enterprise Server Software Support
Enterprise Software Support is an additional support service providing customers with software support on Microsoft, Red Hat, SUSE, and VMware applications and systems. Around the clock availability for critical problems plus unlimited calls and incidents helps customers address challenges fast, without incremental costs. Support staff can answer troubleshooting and diagnostic questions, address product comparability and interoperability issues, isolate causes of problems, report defects to software vendors, and more.
- YourDrive YourData
Lenovo’s YourDrive YourData is a multi-drive retention offering that ensures your data is always under your control, regardless of the number of drives that are installed in your Lenovo server. In the unlikely event of a drive failure, you retain possession of your drive while Lenovo replaces the failed drive part. Your data stays safely on your premises, in your hands. The YourDrive YourData service can be purchased in convenient bundles and is optional with Foundation Service. It is bundled with Essential Service and Advanced Service.
- Health Check
Having a trusted partner who can perform regular and detailed health checks is central to maintaining efficiency and ensuring that your systems and business are always running at their best. Health Check supports Lenovo-branded server, storage, and networking devices, as well as select Lenovo-supported products from other vendors that are sold by Lenovo or a Lenovo-Authorized Reseller.
Examples of region-specific warranty terms are second or longer business day parts delivery or parts-only base warranty.
If warranty terms and conditions include onsite labor for repair or replacement of parts, Lenovo will dispatch a service technician to the customer site to perform the replacement. Onsite labor under base warranty is limited to labor for replacement of parts that have been determined to be field-replaceable units (FRUs). Parts that are determined to be customer-replaceable units (CRUs) do not include onsite labor under base warranty.
If warranty terms include parts-only base warranty, Lenovo is responsible for delivering only replacement parts that are under base warranty (including FRUs) that will be sent to a requested location for self-service. Parts-only service does not include a service technician being dispatched onsite. Parts must be changed at customer’s own cost and labor and defective parts must be returned following the instructions supplied with the spare parts.
Lenovo Service offerings are region-specific. Not all preconfigured support and upgrade options are available in every region. For information about Lenovo service upgrade offerings that are available in your region, refer to the following resources:
- Service part numbers in Lenovo Data Center Solution Configurator (DCSC):
http://dcsc.lenovo.com/#/services - Lenovo Services Availability Locator
http://lenovolocator.com/
For service definitions, region-specific details, and service limitations, please refer to the following documents:
- Lenovo Statement of Limited Warranty for Infrastructure Solutions Group (ISG) Servers and System Storage
http://pcsupport.lenovo.com/us/en/solutions/ht503310 - Lenovo Data Center Services Agreement
http://support.lenovo.com/us/en/solutions/ht116628
Services
Lenovo Services is a dedicated partner to your success. Our goal is to reduce your capital outlays, mitigate your IT risks, and accelerate your time to productivity.
Note: Some service options may not be available in all markets or regions. For more information, go to https://www.lenovo.com/services. For information about Lenovo service upgrade offerings that are available in your region, contact your local Lenovo sales representative or business partner.
Here’s a more in-depth look at what we can do for you:
- Asset Recovery Services
Asset Recovery Services (ARS) helps customers recover the maximum value from their end-of-life equipment in a cost-effective and secure way. On top of simplifying the transition from old to new equipment, ARS mitigates environmental and data security risks associated with data center equipment disposal. Lenovo ARS is a cash-back solution for equipment based on its remaining market value, yielding maximum value from aging assets and lowering total cost of ownership for your customers. For more information, see the ARS page, https://lenovopress.com/lp1266-reduce-e-waste-and-grow-your-bottom-line-with-lenovo-ars.
- Assessment Services
An Assessment helps solve your IT challenges through an onsite, multi-day session with a Lenovo technology expert. We perform a tools-based assessment which provides a comprehensive and thorough review of a company's environment and technology systems. In addition to the technology based functional requirements, the consultant also discusses and records the non-functional business requirements, challenges, and constraints. Assessments help organizations like yours, no matter how large or small, get a better return on your IT investment and overcome challenges in the ever-changing technology landscape.
- Design Services
Professional Services consultants perform infrastructure design and implementation planning to support your strategy. The high-level architectures provided by the assessment service are turned into low level designs and wiring diagrams, which are reviewed and approved prior to implementation. The implementation plan will demonstrate an outcome-based proposal to provide business capabilities through infrastructure with a risk-mitigated project plan.
- Basic Hardware Installation
Lenovo experts can seamlessly manage the physical installation of your server, storage, or networking hardware. Working at a time convenient for you (business hours or off shift), the technician will unpack and inspect the systems on your site, install options, mount in a rack cabinet, connect to power and network, check and update firmware to the latest levels, verify operation, and dispose of the packaging, allowing your team to focus on other priorities.
- Deployment Services
When investing in new IT infrastructures, you need to ensure your business will see quick time to value with little to no disruption. Lenovo deployments are designed by development and engineering teams who know our Products & Solutions better than anyone else, and our technicians own the process from delivery to completion. Lenovo will conduct remote preparation and planning, configure & integrate systems, validate systems, verify and update appliance firmware, train on administrative tasks, and provide post-deployment documentation. Customer’s IT teams leverage our skills to enable IT staff to transform with higher level roles and tasks.
- Integration, Migration, and Expansion Services
Move existing physical & virtual workloads easily, or determine technical requirements to support increased workloads while maximizing performance. Includes tuning, validation, and documenting ongoing run processes. Leverage migration assessment planning documents to perform necessary migrations.
Regulatory compliance
The SE350 V2 conforms to the following standards:
- ANSI/UL62368-1
- IEC 62368-1 (CB Certificate and CB Test Report)
- FCC - Verified to comply with Part 15 of the FCC Rules, Class A
- Canada ICES-003, issue 7, Class A
- CSA C22.2 No. 62368-1
- CISPR 32, Class A, CISPR 35
- Japan VCCI, Class A
- Taiwan BSMI CNS15936, Class A; CNS15598-1; Section 5 of CNS15663
- CE, UKCA Mark (EN55032 Class A, EN62368-1, EN55024, EN55035, EN61000-3-2, EN61000-3-3, (EU) 2019/424, and EN IEC 63000 (RoHS))
- Korea KN32, Class A, KN35
- Russia, Belorussia and Kazakhstan, TP EAC 037/2016 (for RoHS)
- Russia, Belorussia and Kazakhstan, EAC: TP TC 004/2011 (for Safety); TP TC 020/2011 (for EMC)
- EAC Russia, Belorussia and Kazakhstan, TR CU 020/2011 and TR CU 004/2011
- Australia/New Zealand AS/NZS CISPR 32, Class A; AS/NZS 62368.1
- UL Green Guard, UL2819
- China CCC certificate, GB17625.1; GB4943.1; GB/T9254.1
- China CECP certificate, CQC3135
- China CELP certificate, HJ 2507-2011
- Japanese Energy-Saving Act
- Mexico NOM-019
- TUV-GS (EN62368-1, and EK1-ITB2000)
- Germany GS
- Brazil INMETRO
- South Africa NRCS LOA
- Ukraine UkrCEPRO
- Morocco CMIM Certification (CM)
Top-of-rack Ethernet switches
The server supports the top-of-rack Ethernet switches that are listed in the following table. These switches have front-to-rear (reverse) airflow for use with servers where the networking ports are at the front of the server.
Table 44. Top-of-rack switches
Part number | Description |
1 Gb top-of-rack switches | |
7Y810012WW | Lenovo ThinkSystem NE0152T RackSwitch (Front to Rear) |
715952F | Lenovo RackSwitch G8052 (Front to Rear) |
10 Gb top-of-rack switches | |
7159A2X | Lenovo ThinkSystem NE1032 RackSwitch (Front to Rear) |
7159B2X | Lenovo ThinkSystem NE1032T RackSwitch (Front to Rear) |
7159C2X | Lenovo ThinkSystem NE1072T RackSwitch (Front to Rear) |
715964F | Lenovo RackSwitch G8264 (Front to Rear) |
7159DFX | Lenovo RackSwitch G8264CS (Front to Rear) |
7159CFV | Lenovo RackSwitch G8272 (Front to Rear) |
7159GR5 | Lenovo RackSwitch G8296 (Front to Rear) |
7159BF7 | Lenovo RackSwitch G8124E (Front to Rear) |
25 Gb top-of-rack switches | |
7159E2X | Lenovo ThinkSystem NE2572 RackSwitch (Front to Rear) |
40 Gb top-of-rack switches | |
7159BFX | Lenovo RackSwitch G8332 (Front to Rear) |
100 Gb top-of-rack switches | |
7159D2X | Lenovo ThinkSystem NE10032 RackSwitch (Front to Rear) |
For more information, see the list of Product Guides in the Top-of-rack switches categories:
- 1 Gb Ethernet switches: http://lenovopress.com/networking/tor/1gb?rt=product-guide
- 10 Gb Ethernet switches: http://lenovopress.com/networking/tor/10gb?rt=product-guide
- 25 Gb Ethernet switches: https://lenovopress.com/networking/tor/25gb?rt=product-guide
- 40 Gb Ethernet switches: http://lenovopress.com/networking/tor/40gb?rt=product-guide
- 100 Gb Ethernet switches: https://lenovopress.com/networking/tor/100Gb?rt=product-guide
Uninterruptible power supply units
The following table lists the uninterruptible power supply (UPS) units that are offered by Lenovo.
Part number | Description |
---|---|
55941AX | RT1.5kVA 2U Rack or Tower UPS (100-125VAC) |
55941KX | RT1.5kVA 2U Rack or Tower UPS (200-240VAC) |
55942AX | RT2.2kVA 2U Rack or Tower UPS (100-125VAC) |
55942KX | RT2.2kVA 2U Rack or Tower UPS (200-240VAC) |
55943AX | RT3kVA 2U Rack or Tower UPS (100-125VAC) |
55943KX | RT3kVA 2U Rack or Tower UPS (200-240VAC) |
55945KX | RT5kVA 3U Rack or Tower UPS (200-240VAC) |
55946KX | RT6kVA 3U Rack or Tower UPS (200-240VAC) |
55948KX | RT8kVA 6U Rack or Tower UPS (200-240VAC) |
55949KX | RT11kVA 6U Rack or Tower UPS (200-240VAC) |
55948PX | RT8kVA 6U 3:1 Phase Rack or Tower UPS (380-415VAC) |
55949PX | RT11kVA 6U 3:1 Phase Rack or Tower UPS (380-415VAC) |
55943KT† | ThinkSystem RT3kVA 2U Standard UPS (200-230VAC) (2x C13 10A, 2x GB 10A, 1x C19 16A outlets) |
55943LT† | ThinkSystem RT3kVA 2U Long Backup UPS (200-230VAC) (2x C13 10A, 2x GB 10A, 1x C19 16A outlets) |
55946KT† | ThinkSystem RT6kVA 5U UPS (200-230VAC) (2x C13 10A outlets, 1x Terminal Block output) |
5594XKT† | ThinkSystem RT10kVA 5U UPS (200-230VAC) (2x C13 10A outlets, 1x Terminal Block output) |
† Only available in China and the Asia Pacific market.
For more information, see the list of Product Guides in the UPS category:
https://lenovopress.com/servers/options/ups
Power distribution units
The following table lists the power distribution units (PDUs) that are offered by Lenovo.
Part number |
Feature code |
Description |
ANZ
|
ASEAN
|
Brazil
|
EET
|
MEA
|
RUCIS
|
WE
|
HTK
|
INDIA
|
JAPAN
|
LA
|
NA
|
PRC
|
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
0U Basic PDUs | |||||||||||||||
00YJ776 | ATZY | 0U 36 C13/6 C19 24A 1 Phase PDU | N | Y | Y | N | N | N | N | N | N | Y | Y | Y | N |
00YJ779 | ATZX | 0U 21 C13/12 C19 48A 3 Phase PDU | N | N | Y | N | N | N | Y | N | N | Y | Y | Y | N |
00YJ777 | ATZZ | 0U 36 C13/6 C19 32A 1 Phase PDU | Y | Y | N | Y | Y | Y | Y | Y | Y | N | N | Y | Y |
00YJ778 | AU00 | 0U 21 C13/12 C19 32A 3 Phase PDU | Y | Y | N | Y | Y | Y | Y | Y | Y | N | N | Y | Y |
0U Switched and Monitored PDUs | |||||||||||||||
00YJ783 | AU04 | 0U 12 C13/12 C19 Switched and Monitored 48A 3 Phase PDU | N | N | Y | N | N | N | Y | N | N | Y | Y | Y | N |
00YJ781 | AU03 | 0U 20 C13/4 C19 Switched and Monitored 24A 1 Phase PDU | N | N | Y | N | Y | N | Y | N | N | Y | Y | Y | N |
00YJ782 | AU02 | 0U 18 C13/6 C19 Switched and Monitored 32A 3 Phase PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | N | Y |
00YJ780 | AU01 | 0U 20 C13/4 C19 Switched and Monitored 32A 1 Phase PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | N | Y |
1U Switched and Monitored PDUs | |||||||||||||||
4PU7A81117 | BNDV | 1U 18 C19/C13 switched and monitored 48A 3P WYE PDU - ETL | N | N | N | N | N | N | N | N | N | N | N | Y | N |
4PU7A77467 | BLC4 | 1U 18 C19/C13 Switched and Monitored 80A 3P Delta PDU | N | N | N | N | N | N | N | N | N | Y | N | Y | N |
4PU7A77469 | BLC6 | 1U 12 C19/C13 switched and monitored 60A 3P Delta PDU | N | N | N | N | N | N | N | N | N | N | N | Y | N |
4PU7A77468 | BLC5 | 1U 12 C19/C13 switched and monitored 32A 3P WYE PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
4PU7A81118 | BNDW | 1U 18 C19/C13 switched and monitored 48A 3P WYE PDU - CE | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | N | Y |
46M4002 | 5896 | 1U 9 C19/3 C13 Switched and Monitored DPI PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
46M4004 | 5894 | 1U 12 C13 Switched and Monitored DPI PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
46M4003 | 5897 | 1U 9 C19/3 C13 Switched and Monitored 60A 3 Phase PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
46M4005 | 5895 | 1U 12 C13 Switched and Monitored 60A 3 Phase PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
1U Ultra Density Enterprise PDUs (9x IEC 320 C13 + 3x IEC 320 C19 outlets) | |||||||||||||||
71763NU | 6051 | Ultra Density Enterprise C19/C13 PDU 60A/208V/3PH | N | N | Y | N | N | N | N | N | N | Y | Y | Y | N |
71762NX | 6091 | Ultra Density Enterprise C19/C13 PDU Module | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
1U C13 Enterprise PDUs (12x IEC 320 C13 outlets) | |||||||||||||||
39M2816 | 6030 | DPI C13 Enterprise PDU Plus Module (WW) | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
39Y8941 | 6010 | DPI C13 Enterprise PDU Module (WW) | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
1U C19 Enterprise PDUs (6x IEC 320 C19 outlets) | |||||||||||||||
39Y8948 | 6060 | DPI C19 Enterprise PDU Module (WW) | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
39Y8923 | 6061 | DPI Three-phase 60A/208V C19 Enterprise PDU (US) | N | N | Y | N | N | N | Y | N | N | N | Y | Y | N |
1U Front-end PDUs (3x IEC 320 C19 outlets) | |||||||||||||||
39Y8938 | 6002 | DPI Single-phase 30A/120V Front-end PDU (US) | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
39Y8939 | 6003 | DPI Single-phase 30A/208V Front-end PDU (US) | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
39Y8934 | 6005 | DPI Single-phase 32A/230V Front-end PDU (International) | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
39Y8940 | 6004 | DPI Single-phase 60A/208V Front-end PDU (US) | Y | N | Y | Y | Y | Y | Y | N | N | Y | Y | Y | N |
39Y8935 | 6006 | DPI Single-phase 63A/230V Front-end PDU (International) | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
1U NEMA PDUs (6x NEMA 5-15R outlets) | |||||||||||||||
39Y8905 | 5900 | DPI 100-127V NEMA PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Line cords for 1U PDUs that ship without a line cord | |||||||||||||||
40K9611 | 6504 | 4.3m, 32A/380-415V, EPDU/IEC 309 3P+N+G 3ph wye (non-US) Line Cord | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
40K9612 | 6502 | 4.3m, 32A/230V, EPDU to IEC 309 P+N+G (non-US) Line Cord | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
40K9613 | 6503 | 4.3m, 63A/230V, EPDU to IEC 309 P+N+G (non-US) Line Cord | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
40K9614 | 6500 | 4.3m, 30A/208V, EPDU to NEMA L6-30P (US) Line Cord | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
40K9615 | 6501 | 4.3m, 60A/208V, EPDU to IEC 309 2P+G (US) Line Cord | N | N | Y | N | N | N | Y | N | N | Y | Y | Y | N |
40K9617 | 6505 | 4.3m, 32A/230V, Souriau UTG Female to AS/NZ 3112 (Aus/NZ) Line Cord | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
40K9618 | 6506 | 4.3m, 32A/250V, Souriau UTG Female to KSC 8305 (S. Korea) Line Cord | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
For more information, see the Lenovo Press documents in the PDU category:
https://lenovopress.com/servers/options/pdu
Rack cabinets
The SE350 V2 supports installation in a rack when mounted in either the 1U E1 Enclosure or the 2U E2 Enclosure. See Mounting options for details.
Note: The E2 Enclosure is not supported in the 12U and 18U Micro Data Center rack cabinets.
The following table lists the supported rack cabinets.
Part number | Description |
---|---|
93072RX | 25U Standard Rack (1000mm) |
93072PX | 25U Static S2 Standard Rack (1000mm) |
7D6DA007WW | ThinkSystem 42U Onyx Primary Heavy Duty Rack Cabinet (1200mm) |
7D6DA008WW | ThinkSystem 42U Pearl Primary Heavy Duty Rack Cabinet (1200mm) |
93604PX | 42U 1200mm Deep Dynamic Rack |
93614PX | 42U 1200mm Deep Static Rack |
93634PX | 42U 1100mm Dynamic Rack |
93634EX | 42U 1100mm Dynamic Expansion Rack |
93074RX | 42U Standard Rack (1000mm) |
7D6EA009WW | ThinkSystem 48U Onyx Primary Heavy Duty Rack Cabinet (1200mm) |
7D6EA00AWW | ThinkSystem 48U Pearl Primary Heavy Duty Rack Cabinet (1200mm) |
Withdrawn rack cabinets | |
201886X | 11U Office Enablement Kit |
93084PX | 42U Enterprise Rack |
93084EX | 42U Enterprise Expansion Rack |
93604EX | 42U 1200mm Deep Dynamic Expansion Rack |
93614EX | 42U 1200mm Deep Static Expansion Rack |
93074XX | 42U Standard Rack Extension |
93634BX | PureFlex System 42U Expansion Rack |
93634DX | PureFlex System 42U Expansion Rack |
93634AX | PureFlex System 42U Rack |
93634CX | PureFlex System 42U Rack |
93624PX | 47U 1200mm Deep Static Rack |
93624EX | 47U 1200mm Deep Static Expansion Rack |
For specifications about these racks, see the Lenovo Rack Cabinet Reference, available from:
https://lenovopress.com/lp1287-lenovo-rack-cabinet-reference
For more information, see the list of Product Guides in the Rack cabinets category:
https://lenovopress.com/servers/options/racks
Notes:
- The following racks do not support the use of the cable management arm (CMA):
- 25U racks, type 9307
- 42U racks, type 9307
KVM console options
The following table lists the supported KVM consoles.
Part number | Description |
---|---|
Consoles | |
4XF7A84188 | ThinkSystem 18.5" LCD Console (with US English keyboard) |
4XF7A73009 | ThinkSystem 18.5" LCD console (with US English keyboard) |
17238BX | 1U 18.5" Standard Console (without keyboard - see the next table) |
The following table lists the keyboards supported with the 1U 18.5" Standard Console (now withdrawn).
Note: These keyboards are not supported with the ThinkSystem 18.5" LCD Console.
Part number | Description |
---|---|
7ZB7A05469 | ThinkSystem Keyboard w/ Int.Pointing Device USB - Arabic 253 RoHS v2 |
7ZB7A05468 | ThinkSystem Keyboard w/ Int. Pointing Device USB - Belg/UK 120 RoHS v2 |
7ZB7A05206 | ThinkSystem Keyboard w/ Int. Pointing Device USB - Czech 489 RoHS v2 |
7ZB7A05207 | ThinkSystem Keyboard w/ Int. Pointing Device USB - Danish 159 RoHS v2 |
7ZB7A05208 | ThinkSystem Keyboard w/ Int. Pointing Device USB - Dutch 143 RoHS v2 |
7ZB7A05210 | ThinkSystem Keyboard w/ Int. Pointing Device USB - Fr/Canada 445 RoHS v2 |
7ZB7A05209 | ThinkSystem Keyboard w/ Int. Pointing Device USB - French 189 RoHS v2 |
7ZB7A05211 | ThinkSystem Keyboard w/ Int. Pointing Device USB - German 129 RoHS v2 |
7ZB7A05212 | ThinkSystem Keyboard w/ Int. Pointing Device USB - Greek 219 RoHS v2 |
7ZB7A05213 | ThinkSystem Keyboard w/ Int. Pointing Device USB - Hebrew 212 RoHS v2 |
7ZB7A05214 | ThinkSystem Keyboard w/ Int. Pointing Device USB - Hungarian 208 RoHS v2 |
7ZB7A05215 | ThinkSystem Keyboard w/ Int. Pointing Device USB - Italian 141 RoHS v2 |
7ZB7A05216 | ThinkSystem Keyboard w/ Int. Pointing Device USB - Japanese 194 RoHS v2 |
7ZB7A05217 | ThinkSystem Keyboard w/ Int. Pointing Device USB - Korean 413 RoHS v2 |
7ZB7A05218 | ThinkSystem Keyboard w/ Int. Pointing Device USB - LA Span 171 RoHS v2 |
7ZB7A05219 | ThinkSystem Keyboard w/ Int. Pointing Device USB - Norwegian 155 RoHS v2 |
7ZB7A05220 | ThinkSystem Keyboard w/ Int. Pointing Device USB - Polish 214 RoHS v2 |
7ZB7A05221 | ThinkSystem Keyboard w/ Int. Pointing Device USB - Portugese 163 RoHS v2 |
7ZB7A05222 | ThinkSystem Keyboard w/ Int. Pointing Device USB - Russian 441 RoHS v2 |
7ZB7A05223 | ThinkSystem Keyboard w/ Int. Pointing Device USB - Slovak 245 RoHS v2 |
7ZB7A05231 | ThinkSystem Keyboard w/ Int. Pointing Device USB - Slovenian 234 RoHS v2 |
7ZB7A05224 | ThinkSystem Keyboard w/ Int. Pointing Device USB - Spanish 172 RoHS v2 |
7ZB7A05225 | ThinkSystem Keyboard w/ Int. Pointing Device USB - Swed/Finn 153 RoHS v2 |
7ZB7A05226 | ThinkSystem Keyboard w/ Int. Pointing Device USB - Swiss F/G 150 RoHS v2 |
7ZB7A05227 | ThinkSystem Keyboard w/ Int. Pointing Device USB - Thai 191 RoHS v2 |
7ZB7A05467 | ThinkSystem Keyboard with Int. Pointing Device USB - Trad Chinese/US 467 RoHS v2 |
7ZB7A05228 | ThinkSystem Keyboard w/ Int. Pointing Device USB - Turkish 179 RoHS v2 |
7ZB7A05229 | ThinkSystem Keyboard w/ Int. Pointing Device USB - UK Eng 166 RoHS v2 |
7ZB7A05470 | ThinkSystem Keyboard w/ Int. Pointing Device USB - US Eng 103P RoHS v2 |
7ZB7A05230 | ThinkSystem Keyboard w/ Int. Pointing Device USB - US Euro 103P RoHS v2 |
The following table lists the available KVM switches and the options that are supported with them.
Part number | Description |
---|---|
KVM Console switches | |
1754D1T | ThinkSystem Digital 2x1x16 KVM Switch (DVI video output port) |
1754A1T | ThinkSystem Analog 1x8 KVM Switch (DVI video output port) |
1754D2X | Global 4x2x32 Console Manager (GCM32) |
1754D1X | Global 2x2x16 Console Manager (GCM16) |
1754A2X | Local 2x16 Console Manager (LCM16) |
1754A1X | Local 1x8 Console Manager (LCM8) |
Cables for ThinkSystem Digital and Analog KVM Console switches | |
4X97A11108 | ThinkSystem VGA to DVI Conversion Cable |
4X97A11109 | ThinkSystem Single-USB Conversion Cable for Digital KVM |
4X97A11107 | ThinkSystem Dual-USB Conversion Cable for Digital KVM |
4X97A11106 | ThinkSystem USB Conversion Cable for Analog KVM |
Cables for GCM and LCM Console switches | |
43V6147 | Single Cable USB Conversion Option (UCO) |
39M2895 | USB Conversion Option Pack |
46M5383 | Virtual Media Conversion Option Gen2 (VCO2) |
46M5382 | Serial Conversion Option (SCO) |
For more information, see the list of Product Guides in the KVM Switches and Consoles category:
http://lenovopress.com/servers/options/kvm
Lenovo Financial Services
Lenovo Financial Services reinforces Lenovo’s commitment to deliver pioneering products and services that are recognized for their quality, excellence, and trustworthiness. Lenovo Financial Services offers financing solutions and services that complement your technology solution anywhere in the world.
We are dedicated to delivering a positive finance experience for customers like you who want to maximize your purchase power by obtaining the technology you need today, protect against technology obsolescence, and preserve your capital for other uses.
We work with businesses, non-profit organizations, governments and educational institutions to finance their entire technology solution. We focus on making it easy to do business with us. Our highly experienced team of finance professionals operates in a work culture that emphasizes the importance of providing outstanding customer service. Our systems, processes and flexible policies support our goal of providing customers with a positive experience.
We finance your entire solution. Unlike others, we allow you to bundle everything you need from hardware and software to service contracts, installation costs, training fees, and sales tax. If you decide weeks or months later to add to your solution, we can consolidate everything into a single invoice.
Our Premier Client services provide large accounts with special handling services to ensure these complex transactions are serviced properly. As a premier client, you have a dedicated finance specialist who manages your account through its life, from first invoice through asset return or purchase. This specialist develops an in-depth understanding of your invoice and payment requirements. For you, this dedication provides a high-quality, easy, and positive financing experience.
For your region-specific offers, please ask your Lenovo sales representative or your technology provider about the use of Lenovo Financial Services. For more information, see the following Lenovo website:
https://www.lenovo.com/us/en/landingpage/lenovo-financial-services/
Seller training courses
The following sales training courses are offered for employees and partners (login required). Courses are listed in date order.
-
VTT: ThinkEdge SE350V2 and ThinkEdge SE360 V2, Wave 2 - What's new for bringing AI and computing to the source of the data?
2023-11-03 | 75 minutes | Employees Only
DetailsVTT: ThinkEdge SE350V2 and ThinkEdge SE360 V2, Wave 2 - What's new for bringing AI and computing to the source of the data?Join Aaron Shao, Sr. Product Manager from Lenovo ThinkEdge Business Unit, as he explores details of the added features for the SE350 V2 and SE360 V2 in Wave 2. Aaron will cover generation transition and product selling points as he discusses customer advantages of the SE350 V2 and SE360 V2 in the context of AI and compute.
Published: 2023-11-03
Length: 75 minutes
Employee link: Grow@Lenovo
Course code: DVEDG207 -
VTT: Edge Product Innovation, ISVs, and Market trends - AP & PRC, Oct. 2023
2023-10-12 | 60 minutes | Employees Only
DetailsVTT: Edge Product Innovation, ISVs, and Market trends - AP & PRC, Oct. 2023Join Richard Jenkins from the AP Edge solutions group as he discusses the difference between Industrial Internet of things (IoT) and Operational Technology (OT). Richard takes a look at how both are relevant to combining edge servers with hybrid cloud architecture. Topics include:
Published: 2023-10-12
• Integration of ISV Concepts
• Edge serving clusters and megaclusters
• Container designs for SE10, SE30 & SE50
Length: 60 minutes
Employee link: Grow@Lenovo
Course code: DVEDG206 -
VTT: Edge Product Innovation, ISVs, and Market trends - EMEA, LA & NA, Oct. 2023
2023-10-11 | 60 minutes | Employees Only
DetailsVTT: Edge Product Innovation, ISVs, and Market trends - EMEA, LA & NA, Oct. 2023Join Per Ljungstrom and Anthony Sayers as they discuss the difference between Industrial Internet of things (IoT) and Operational Technology (OT). They look at how both are relevant to combining edge servers with hybrid cloud architecture. Topics include:
Published: 2023-10-11
• Integration of ISV Concepts
• Edge serving clusters and megaclusters
• Container designs for SE10, SE30 & SE50
Length: 60 minutes
Employee link: Grow@Lenovo
Course code: DVEDG205 -
Partner Technical Webinar - StorMagic
2023-10-02 | 60 minutes | Employees and Partners
DetailsPartner Technical Webinar - StorMagicIn this 60-minute replay, Wes Ganeko and Craig Collier from StorMagic reviewed the need for Storage at the Edge, StorMagic’s involvement in the Lenovo AI Innovators program and a deep dive into SvSAN, StorMagic’s flagship product for simple hyperconverged storage.
Published: 2023-10-02
Length: 60 minutes
Employee link: Grow@Lenovo
Partner link: Lenovo Partner Learning
Course code: 092923 -
Family Portfolio - Edge
2023-09-12 | 15 minutes | Employees and Partners
DetailsFamily Portfolio - EdgeThis course introduces edge environments, and the roles played by Lenovo edge servers and edge clients in those environments. It looks briefly at use cases for these edge devices.
Published: 2023-09-12
When you have completed this course, you should be able to list the edge solutions in the Lenovo portfolio, describe the features of each solution, and determine which solution is best suited to a specific environment.
Length: 15 minutes
Employee link: Grow@Lenovo
Partner link: Lenovo Partner Learning
Course code: SXXW2513r2 -
The 10-minute Edge conversation for Lenovo Sellers
2023-09-04 | 20 minutes | Employees and Partners
DetailsThe 10-minute Edge conversation for Lenovo SellersThe purpose of this course is to enable sellers to have a 10 to 15 minutes customer conversation addressing the relevancy of Edge solutions to the customer business.
Published: 2023-09-04
Learning Objectives:
• Prepare for the initial customer conversation
• Hold a 10 minute Edge Operational Technology (OT) conversation
• Take the appropriate steps to progress the sale
Length: 20 minutes
Employee link: Grow@Lenovo
Partner link: Lenovo Partner Learning
Course code: DTEF103 -
VTT: VMware Edge Compute Stack, August 2023
2023-08-17 | 60 minutes | Employees Only
DetailsVTT: VMware Edge Compute Stack, August 2023Edge Compute drives business transformation in sectors like retail, manufacturing & utilities. It intersects with IoT sensors, robotics & AI, and supports use cases requiring computing closer to operations. Implementing Edge Compute at scale requires a platform supporting verticalized applications, manageability, reliability & security. Join Josh David from VMware and Alejandro Perez from Lenovo as they discuss how the VMware Edge Stack enables real-time intelligence & immersive experiences at the Edge.
Published: 2023-08-17
Length: 60 minutes
Employee link: Grow@Lenovo
Course code: DVEDG203 -
Basics of the Edge Ecosystem for Sellers
2023-08-03 | 20 minutes | Employees and Partners
DetailsBasics of the Edge Ecosystem for SellersThe purpose of this course is to familiarize Lenovo field sales, inside sales, and partners with the Edge ecosystem and how Lenovo fits into the Edge space.
Published: 2023-08-03
Learning Objectives:
• Explain the basics of an Edge Ecosystem
• Articulate the inherent challenges of Edge Computing
• Present how Lenovo fits in the Edge Ecosystem
Length: 20 minutes
Employee link: Grow@Lenovo
Partner link: Lenovo Partner Learning
Course code: DTEF101 -
Lenovo Data Center Product Portfolio
2023-07-21 | 15 minutes | Employees and Partners
DetailsLenovo Data Center Product PortfolioThis course introduces the Lenovo data center portfolio, and covers servers, storage, storage networking, and software-defined infrastructure products. After completing this course about Lenovo data center products, you will be able to identify product types within each data center family, describe Lenovo innovations that this product family or category uses, and recognize when a specific product should be selected.
Published: 2023-07-21
Length: 15 minutes
Employee link: Grow@Lenovo
Partner link: Lenovo Partner Learning
Course code: SXXW1110r6 -
VTT: SAP HANA Transition and Refresh Opportunity - July 2023
2023-07-14 | 60 minutes | Employees Only
DetailsVTT: SAP HANA Transition and Refresh Opportunity - July 2023In this session, we cover:
Published: 2023-07-14
- What Next for SAP Clients?
- Lenovo Opportunity
- Lenovo Portfolio for SAP Solutions
- RISE with SAP
Length: 60 minutes
Employee link: Grow@Lenovo
Course code: DVDAT202 -
Partner Technical Webinar - ThinkEdge SE350 V2 & SE360 V2 Update
2023-07-13 | 60 minutes | Employees and Partners
DetailsPartner Technical Webinar - ThinkEdge SE350 V2 & SE360 V2 UpdateJuly 7, 2023 – in this 60-minute replay, Benoit Robert, Director - Edge Server Product Management, reviewed the ThinkEdge portfolio specifically the SE350v2 and SE360v2. Benoit discussed the key differences between the 2 edge servers with a focus on form factors and use cases.
Published: 2023-07-13
Length: 60 minutes
Employee link: Grow@Lenovo
Partner link: Lenovo Partner Learning
Course code: 070723 -
Partner Technical Webinar - Server Review with Mark Bica
2023-06-20 | 60 minutes | Employees and Partners
DetailsPartner Technical Webinar - Server Review with Mark BicaIn this 60-minute replay, Mark Bica, Lenovo ThinkSystem Brand Manager, reviewed currently ThinkSystem Server portfolio. He highlighted recent server announcements including the SE350 V2, SE360 V2 and SR675 V3. Joe Murphy, Lenovo Solution Architect concluded the session with a demo of how to get Estimated Ship Dates in DCSC.
Published: 2023-06-20
Length: 60 minutes
Employee link: Grow@Lenovo
Partner link: Lenovo Partner Learning
Course code: 061623 -
VTT: Lenovo in the Era of the Edge - June 2023
2023-06-15 | 55 minutes | Employees Only
DetailsVTT: Lenovo in the Era of the Edge - June 2023Join Richard Jenkins from the Lenovo Edge Computing Business Development group as he discusses how Lenovo fits in the era of the Edge. Topics covered in this VTT session include:
Published: 2023-06-15
- customer use cases at the Edge
- the needed consortium to build an Edge Solution
- Lenovo edge portfolio
- The advantages of LOC-A and XClarity at the Edge
Length: 55 minutes
Employee link: Grow@Lenovo
Course code: DVEDG201 -
FY24Q1 AI Launch
2023-06-14 | 15 minutes | Employees and Partners
DetailsFY24Q1 AI LaunchThis course covers the exciting announcements that Lenovo is making about its commitment to AI. Not only has Lenovo pledged to invest $1B in AI over the next three years, and committed $100M to bolster the Lenovo AI Innovators Program, but there are also some exciting product announcements.
Published: 2023-06-14
Once you complete this course, you should be able to define intelligence and artificial intelligence, describe a digital twin, and discuss the three key points of the Lenovo AI launch: investment in AI, a new AI-capable data center server, and new AI-capable edge servers.
Length: 15 minutes
Employee link: Grow@Lenovo
Partner link: Lenovo Partner Learning
Course code: SXXW2516 -
Lenovo XClarity Management Hub for Edge Server Devices
2023-06-08 | 50 minutes | Employees and Partners
DetailsLenovo XClarity Management Hub for Edge Server DevicesThis course offers a comprehensive overview and demonstration of the enhanced capability to manage ThinkEdge Server Devices through Lenovo XClarity Management Hub in Lenovo XClarity Orchestrator (LXCO).
Published: 2023-06-08
Length: 50 minutes
Employee link: Grow@Lenovo
Partner link: Lenovo Partner Learning
Course code: DXCO201 -
Lenovo XClarity Management Hub for Edge Client Devices
2023-06-08 | 50 minutes | Employees and Partners
DetailsLenovo XClarity Management Hub for Edge Client DevicesThis course offers a comprehensive overview and demonstration of the enhanced capability to manage ThinkEdge Client Devices through Lenovo XClarity Management Hub in Lenovo XClarity Orchestrator (LXCO).
Published: 2023-06-08
Length: 50 minutes
Employee link: Grow@Lenovo
Partner link: Lenovo Partner Learning
Course code: DXCO202 -
Family Portfolio: Intel Edge Servers
2023-06-07 | 15 minutes | Employees and Partners
DetailsFamily Portfolio: Intel Edge ServersThis course introduces two new Lenovo ThinkEdge servers: the ThinkEdge SE350 V2 and ThinkEdge SE360 V2.
Published: 2023-06-07
After completing this course, you will be able to list the Intel edge servers in the Lenovo portfolio, describe the features of each server and determine which server is best suited to a specific environment.
Length: 15 minutes
Employee link: Grow@Lenovo
Partner link: Lenovo Partner Learning
Course code: SXXW2510r2 -
Lenovo FY24Q2 AI Announcement QH
2023-06-07 | 3 minutes | Employees and Partners
DetailsLenovo FY24Q2 AI Announcement QHThis Quick Hit covers the exciting announcements Lenovo is making about its commitment to AI. Lenovo has pledged to invest $1B in AI over the next three years, and has committed $100M to bolster the Lenovo AI Innovators Program to develop AI-Ready solutions faster. Two new servers are being added to the already impressive Lenovo Edge portfolio – the ThinkEdge SE350 V2 and ThinkEdge SE360 V2. These servers offer a wide operating temperature range and the ruggedness to handle shock, vibration, and airborne contaminants. The SE360 V2 supports GPUs, making it ideal for AI at the edge. Both servers support the new time-sensitive networking protocol, TSN, to ensure that response times are low and deterministic.
Published: 2023-06-07
Note: This course is presented as audio only. There are no slides or video.
Length: 3 minutes
Employee link: Grow@Lenovo
Partner link: Lenovo Partner Learning
Course code: SXXW2516a -
Partner Technical Webinar - Smart Cities with ThinkEdge
2022-12-13 | 60 minutes | Partners Only
DetailsPartner Technical Webinar - Smart Cities with ThinkEdgeIn this 60-minute replay, Alejandro Perez, Lenovo Americas Edge Solutions Leader, discussed the Edge applications of Smart Cities, specifically the City of Barcelona. Alejandro reviewed the key uses of the solution and the underlying architecture including the Lenovo SE350, SE450 and Lenovo Open Cloud Automation software.
Published: 2022-12-13
Length: 60 minutes
Partner link: Lenovo Partner Learning
Course code: 120922 -
Technical Champions Webinar: Edge Computing Enables New Possibilities
2022-12-09 | 64 minutes | Employees Only
DetailsTechnical Champions Webinar: Edge Computing Enables New PossibilitiesThe Lenovo launch of both ThinkEdge SE350 and SE450 helps to resolve edge computing requirements and enables new possibilities for a variety of verticals. Join Aaron Shao, Lenovo Edge Product Manager, as he discusses the big picture of edge computing and positioning of the Lenovo ThinkEdge portfolio. Aaron will take a deep dive into the latest news from the most GPU rich edge server in the industry, the Lenovo ThinkEdge SE450. Two outstanding customer stories and their application of Edge computing will also be featured as well.
Published: 2022-12-09
Length: 64 minutes
Employee link: Grow@Lenovo
Course code: DTEO101 -
Technical Champions Webinar: Lenovo Edge Solutions: Unleash the Power of AI Solutions at the Edge
2022-10-13 | 60 minutes | Employees and Partners
DetailsTechnical Champions Webinar: Lenovo Edge Solutions: Unleash the Power of AI Solutions at the EdgeView this Technical Champions Webinar (recorded October 10, 2022) to learn about Lenovo's Edge solutions. Join Alejandro Perez Quintero as he discusses the elements of Edge computing, the growth of the Edge and the connection with AI.
Published: 2022-10-13
This webinar covers:
- Drivers for Edge Technology
- Lenovo Edge Solutions
- Customer use cases
Length: 60 minutes
Employee link: Grow@Lenovo
Partner link: Lenovo Partner Learning
Course code: DEDGP100
1-10 of 21 courses.
Related publications and links
For more information, see these resources:
- ThinkSystem SE350 V2 drivers and support
https://datacentersupport.lenovo.com/us/en/ - Lenovo ThinkSystem SE350 V2 product page:
- https://www.lenovo.com/us/en/p/servers-storage/servers/edge/ThinkEdge-SE350-V2/LEN21TS0018
- Interactive 3D Tour of the ThinkEdge SE350 V2:
https://lenovopress.lenovo.com/lp1751 - ServerProven hardware compatibility:
https://serverproven.lenovo.com/ - Lenovo Server Options:
https://serveroption.lenovo.com/
Related product families
Product families related to this document are the following:
Trademarks
Lenovo and the Lenovo logo are trademarks or registered trademarks of Lenovo in the United States, other countries, or both. A current list of Lenovo trademarks is available on the Web at https://www.lenovo.com/us/en/legal/copytrade/.
The following terms are trademarks of Lenovo in the United States, other countries, or both:
Lenovo®
Bootable Media Creator
Flex System
Lenovo Services
RackSwitch
ServerProven®
System x®
ThinkEdge®
ThinkShield®
ThinkServer®
ThinkSystem®
TruDDR4
UpdateXpress System Packs
XClarity®
The following terms are trademarks of other companies:
Intel® and Xeon® are trademarks of Intel Corporation or its subsidiaries.
Linux® is the trademark of Linus Torvalds in the U.S. and other countries.
Microsoft®, ActiveX®, Hyper-V®, PowerShell, Windows PowerShell®, Windows Server®, and Windows® are trademarks of Microsoft Corporation in the United States, other countries, or both.
Other company, product, or service names may be trademarks or service marks of others.
Configure and Buy
Full Change History
Changes in the November 17, 2023 update:
- Added back supported ESXi version under Operating system support section
- VMware ESXi 8.0 U1
- Added a new power table details under Mounting options section
Changes in the November 7, 2023 update:
- Added a new Augmented Reality section
- Added a new supported option under Operating system support section
- VMware ESXi 8.0 U2
- Added a new supported option under Operating environment section
- System Operational Temperature 0C to 55C / 32F to 131F, B8ZU
- Added a new supported option under Security section
- XClarity Controller Managed, BYBQ
- SED Enabled, BYBS
- System Lockdown Mode
- SED encryption
- System Guard
- Lenovo ThinkShield
- Added a new supported option under Power supplies section
- ThinkEdge SE350 V2 External DC Terminal Block Cable, BS4C
- ThinkEdge SE350 V2 500W 230V/115V Non-Hot Swap Power Supply, BWK7
- ThinkEdge SE350 V2 AC Power Input Board, BUGP
- Added a new supported option under Mounting options section
- ThinkEdge DIN Mount Kit (Extreme Shock & Vibe), B87S
- ThinkEdge SE350 V2 Security Bezel for 10/25GbE I/O Module, BS4F
- ThinkSystem Enclosure Universal Short Rack Rail Kit, BS30
- ThinkEdge Node Sleeve, B6EZ
- ThinkEdge SE350 V2 Security Bezel for 1GbE I/O Module, BS4G
- ThinkEdge SE350 V2 Security Bezel Dust Filter, BS4H
- ThinkEdge SE350 V2 1U2N Enclosure (AC), BVGY
- wall mount
- DIN mount
Changes in the September 5, 2023 update:
- Included note: 20-core processor support available via special bid/CORE - Processors section
Changes in the August 18, 2023 update:
- Updated the list of agency approvals - Regulatory compliance section
Changes in the August 4, 2023 update:
- Added updates to Intel VROC NVMe RAID - Controllers for internal storage section
First published: July 18, 2023