The Lenovo System x3950 X6 server, machine type 6241, is an eight-socket 8U rack-mounted server that represents the sixth generation of the Enterprise X-Architecture. Now with Intel Xeon E7 v4 processors, the x3950 X6 delivers fast application performance, is based on an agile system design, and is a resilient platform that is needed for mission-critical databases, enterprise applications, and virtualized environments.
This product guide provides essential pre-sales information to understand the x3950 X6 server, its key features and specifications, components and options, and configuration guidelines. This guide is intended for technical specialists, sales specialists, sales engineers, IT architects, and other IT professionals who want to learn more about the x3950 X6 and consider its use in IT solutions.
Withdrawn: The System x3950 X6 is now withdrawn from marketing.
Change History
Changes in April 14 and 18 updates:
- Updated all drive options tables - Internal drive options section
- Updated the Warranty and Support section
- Added the Services section
Learn about the x3950 X6 with David Watts and Randy Lundin
Introduction
The Lenovo System x3950 X6 server, machine type 6241, is an eight-socket 8U rack-mounted server that represents the sixth generation of the Enterprise X-Architecture. Now with Intel Xeon E7 v4 processors, the x3950 X6 delivers fast application performance, is based on an agile system design, and is a resilient platform that is needed for mission-critical databases, enterprise applications, and virtualized environments.
The x3950 X6 packs numerous fault-tolerant and high-availability features into a high-density, 8U rack-optimized lid-less package that helps reduce the space that is needed to support massive network computing operations and simplify servicing. The x3950 X6 supports up to eight Intel Xeon E7 processors and up to 24 TB of memory.
Suggested use: mission-critical scalable databases, business analytics, virtualization, enterprise applications, and cloud applications.
Figure 1. Lenovo System x3950 X6
Did you know?
The x3950 X6 server employs a lid-less design where all serviceable components are front- and rear-accessible. In addition, each major subsystem is implemented as modular "book" design, such as the Compute Books and I/O Books. This configuration means that components are easy to upgrade and service, which translates to greater uptime of applications to your users. The x3950 X6 offers enterprise scalability and advanced RAS features to support the most demanding mission-critical applications that require 24x7 operations.
Key features
The increasing demand for cloud-computing and analytics workloads by enterprises to meet social, mobile, and Big Data requirements drives innovation to find new ways to build informational systems. Clients are looking for cost-optimized fit-for-purpose IT solutions that manage large amounts of data, easily scale performance, and provide enterprise class reliability.
Built on decades of innovation, Lenovo introduces its sixth generation of Enterprise X-Architecture technology, X6 servers. Lenovo X6 servers are fast, agile, and resilient:
- Fast application performance means immediate access to actionable information.
- Agile system design helps to reduce acquisition costs and provide the ability to upgrade processor and memory technology at each refresh within the same chassis.
- Resilient platforms maximize application uptime and promote easy integration in virtual environments.
X6 servers continue to lead the way as the shift toward mission-critical scalable databases, business analytics, virtualization, enterprise applications, and cloud-computing applications accelerates.
Fast application performance
The server offers numerous features to boost performance:
- Based on the Intel Xeon E7 family of processors:
- Models based on E7-8800 v4 processors
- Supports up to eight E7 v4 processors with a total of 192 cores and 384 threads to maximize the concurrent running of multi-threaded applications.
- Improves productivity by offering superior system performance with processors up to 24 cores, core frequencies up to 3.2 GHz core speeds, L3 cache of up to 60 MB, and three QPI interconnect links at up to 9.6 GTps.
- Supports DDR4 memory at speeds up to 1866 MHz, or DDR3 memory at speeds up to 1600 MHz
- Supports up to 192 DIMM sockets, with 24 DIMMs per processor.
- Intelligent and adaptive system performance with Intel Turbo Boost Technology 2.0 allows processor cores to run at maximum speeds during peak workloads by temporarily going beyond processor thermal design power (TDP).
- Intel Hyper-Threading Technology boosts performance for multi-threaded applications by enabling simultaneous multi-threading within each processor core, up to two threads per core.
- Intel Virtualization Technology integrates hardware-level virtualization hooks that allow operating system vendors to better use the hardware for virtualization workloads.
- Intel Advanced Vector Extensions (AVX) improves floating-point performance for compute-intensive technical and scientific applications.
- Supports a 12 Gbps SAS RAID portfolio.
- The usage of solid-state drives (SSDs) instead of, or along with, traditional spinning drives (HDDs) can improve I/O performance. An SSD can support up to 100 times more I/O operations per second (IOPS) than a typical HDD.
- Optional support for high-performance PCIe-attached NVMe Flash Storage solid-state drives (SSDs) can significantly improve I/O performance.
- PCI Express 3.0 I/O adapter slots that improve the theoretical maximum bandwidth by almost 100% (8 GTps per link using 128b/130b encoding) compared to the previous generation of PCI Express 2.0 (5 GTps per link using 8b/10b encoding).
- With Intel Integrated I/O Technology, the PCI Express 3.0 controller is integrated into the Intel Xeon processor. This integration helps reduce I/O latency and increase overall system performance.
- Support for up to four graphics processing units (GPUs) and co-processors to maximize computing power.
- Energy-efficient electronic components help lower operational costs, including highly efficient 900 W AC and 1400 W AC power supplies with 80 PLUS Platinum certification.
- Energy Star 2.0 compliant
Agile system design
The server provides many scalability and flexibility features:
- Innovative module "book" design for each of the three subsystems: Compute Books, Storage Book, and I/O Books. Front and rear access means that you can easily scale the system by adding components without removing the entire server from the rack.
- The modular book design also allows clients to create the configuration that fits their application and environment needs, which reduces acquisition costs while giving them the flexibility to grow and modify their configuration later.
- The book design also means that subsystem upgrades are simpler, quicker to perform, and have a lower impact on the rest of the server.
- Using 128 GB 3DS RDIMMs, the server supports up to 24 TB of memory.
- Up to 32x 1.8-inch SSD bays, or up to 16x 2.5-inch bays, provide a flexible and scalable all-in-one platform to meet your increasing demands.
- Offers up to 22 PCIe slots plus two dedicated Mezzanine LOM (ML2) adapter slots. Most slots are PCIe 3.0 to maximize I/O scalability.
- PCIe slots are implemented in I/O Books to maximize modularity. Choose from Half-length I/O Books or Full-length I/O Books, depending on the adapters that you need to deploy.
- Most components are common between the four-socket x3850 X6 and eight-socket x3950 X6, making for a simple upgrade path with minimal parts on the floor.
Resilient platform
The server provides many features to simplify serviceability and increase system uptime:
- Upward Integration Modules for standard hypervisors enable the creation and management of policies to maintain high availability of virtual machines and concurrent updating of the system firmware, with no impact on application performance or availability.
- Advanced Processor Recovery allows the system to automatically switch access and control of networking, management, and storage in the event of a processor 1 failure, providing higher availability and productivity.
- Advanced Page Retire proactively protects applications from corrupted pages in memory, which is crucial for scaling memory to terabytes.
- Redundant bit steering, memory mirroring, and memory rank sparing for redundancy in the event of a non-correctable memory failure.
- Intel Execute Disable Bit functionality can help prevent certain classes of malicious buffer overflow attacks when combined with a supported operating system.
- Intel Trusted Execution Technology provides enhanced security through hardware-based resistance to malicious software attacks, allowing an application to run in its own isolated space, which is protected from all other software running on a system.
- Redundant Intel Platform Controller Hub (PCH) connections to the processors allow the platform to maintain access to networking, storage, and server management during a processor failure.
- Hot-swap drives support RAID redundancy for data protection and greater system uptime.
- Hot-swap I/O Books enabling you to install or replace adapters while the server is still running.
- Tool-less lid-less design provides front and rear access for easy upgrades and serviceability. There is no need to pull the server out of the rack to access internal components.
- Hot-swap power supplies and hot-swap dual-motor redundant fans provide availability for mission-critical applications.
- An LCD diagnostics panel that is combined with individual light path diagnostic LEDs quickly lead the technician to failed (or failing) components, which simplifies servicing, speeds up problem resolution, and helps improve system availability.
- Proactive Platform Alerts (including PFA and SMART alerts): Processors, voltage regulators, memory, internal storage (SAS/SATA HDDs and SSDs, NVMe SSDs, flash storage adapters), fans, power supplies, RAID controllers, and server ambient and sub-component temperatures. Alerts can be surfaced through the system IMM to managers such as Lenovo XClarity Administrator, VMware vCenter, and Microsoft System Center. These proactive alerts let you take appropriate actions in advance of possible failure, thereby increasing server uptime and application availability.
- Built-in Integrated Management Module Version II (IMM2) continuously monitors system parameters, triggers alerts, and performs recovering actions in case of failures to minimize downtime.
- Includes two special Mezzanine LOM (ML2) adapter slots with support for adapters with either two 10 Gb ports or four 1 Gb ports. Supports direct connectivity to the IMM2 service processor for out-of-band systems management.
- Integrated industry-standard Unified Extensible Firmware Interface (UEFI) enables improved setup, configuration, and updates, and simplifies error handling.
- Integrated Trusted Platform Module (TPM) supporting TPM 2.0 and TPM 1.2 enables advanced cryptographic functionality, such as digital signatures and remote attestation.
- Industry-standard Advanced Encryption Standard (AES) NI support for faster and stronger encryption.
- Lenovo XClarity Administrator provides proactive systems management. It offers comprehensive systems management tools that help increase uptime, reduce costs, and improve productivity through advanced server management capabilities.
- Solid-state drives (SSDs) offer better reliability than traditional mechanical HDDs for greater uptime.
- Built-in diagnostic tests, using Dynamic Systems Analysis (DSA) Preboot, speed up troubleshooting tasks to reduce service time.
- Three-year customer-replaceable unit and onsite limited warranty, 9x5 next business day. Optional service upgrades are available.
Locations of key components and connectors
The following figure shows the front of the x3950 X6 server.
Figure 2. Front view of the Lenovo System x3950 X6
The following figure shows the rear of the x3950 X6 server.
Figure 3. Rear view of the Lenovo System x3950 X6
Standard specifications
The following table lists the standard specifications.
Components | Specification |
---|---|
Machine type | 6241 |
Firmware | Lenovo-signed firmware |
Form factor | 8U rack |
Processor | Four, six or eight Intel Xeon E7-8800 v4 processors, each in a Compute Book. Processor options have between 4 and 24 cores with core frequencies up to 3.2 GHz. Three QPI links up to 9.6 GT/s each. Compute Books have TruDDR4 memory up to 1866 MHz, but cannot be mixed. Up to 60 MB L3 cache. Intel C602J chipset. |
Memory | Up to 192 DIMM sockets (24 DIMMs per processor, installed in the Compute Book). RDIMMs and LRDIMMs (Load Reduced DIMMs) are supported, but memory types cannot be intermixed. Memory is either TruDDR4 memory (up to 1866 MHz) or DDR3 memory (up to 1600 MHz), depending on the Compute Book selected. DDR3 memory and TruDDR4 memory cannot be mixed in the same Compute Book. Compute Books with DDR3 memory and Compute Books with TruDDR4 memory cannot be mixed in the same system. |
Memory maximums |
With RDIMMs: Up to 6 TB with 192x 32 GB RDIMMs and eight processors |
Memory protection | ECC, Chipkill, RBS, memory mirroring, and memory rank sparing. |
Disk drive bays | Up to 32x 1.8" SSD bays, or up to 16x 2.5" hot-swap SAS/SATA bays, or up to 8x 2.5” hot-swap PCIe NVMe SSD drive bays. |
Maximum internal storage | Up to 122.9 TB with 16x 7.68 TB 2.5-inch SAS SSDs, or Up to 32 TB with 16x 2 TB 2.5-inch SAS HDDs, or Up to 32 TB with 8x 4 TB 2.5-inch PCIe NVMe SSDs |
RAID support | 12 Gb SAS/SATA RAID 0, 1, or 10 with ServeRAID M5210; optional upgrades to RAID 5 or 50 are available (zero-cache; 1 GB non-backed cache; 1 GB or 2 GB flash-backed cache). Upgrades to RAID 6 or 60 available for M5210 with 1 GB or 2 GB upgrades. |
Optical and tape bays | No internal bays. See http://support.lenovo.com/en/documents/pd011281 for external DVD options. |
Network interfaces | Mezzanine LOM (ML2) slots for dual-port 10 GbE cards with SFP+ or RJ-45 connectors or quad-port GbE cards with RJ-45 connectors. See Table 2. Dedicated 1 GbE port for systems management. |
PCI Expansion slots | Up to 22 PCIe slots plus two dedicated Mezzanine LOM slots. The slots are as follows:
|
Ports | Front: Four USB 3.0, two USB 2.0, and one VGA video ports. Rear: Eight USB 2.0, two VGA video, two DB-9 serial, and two1 GbE RJ-45 IMM2 systems management. Internal: two USB 2.0 port for embedded hypervisor. The second video, IMM2, and internal USB hypervisor ports are used only when the server is partitioned into two four-socket servers. |
Cooling | Calibrated Vectored Cooling™. Up to 20 redundant hot-swap fan packs and 10 fan zones with N+1 fan redundancy. Each fan pack includes two counter-rotated dual-motor fans. |
Power supply | Up to eight redundant hot-swap 900 W AC or 1400 W AC power supplies (all 80 PLUS Platinum certified). -48 V 750 W DC power supplies are available through CTO. |
Hot-swap parts | Drives, power supplies, fans, and optional I/O Books. |
Video | Matrox G200eR2 with 16 MB memory that is integrated into the IMM2. Maximum resolution is 1600 x 1200 at 75 Hz with 16 M colors. |
Security features | Power-on password, admin password, and two Trusted Platform Modules supporting TPM 2.0 and TPM 1.2. |
Systems management | UEFI, Integrated Management Module II (IMM2) with remote presence feature, Predictive Failure Analysis, Light Path Diagnostics, Automatic Server Restart, Lenovo XClarity Administrator, Lenovo XClarity Integrators, and ServerGuide. |
Operating systems supported | Microsoft Windows Server, Red Hat Enterprise Linux, SUSE Linux Enterprise Server, VMware ESXi. See the Operating system support section for specifics. |
Limited warranty | Three-year customer-replaceable unit (CRU) and onsite limited warranty with 9x5 next business day (NBD). |
Service and support | Optional service upgrades are available through Lenovo Services offerings: 4-hour or 2-hour response time, 8-hour fix time, 1-year or 2-year warranty extension, and remote technical support for Lenovo hardware and some Lenovo / OEM applications. |
Dimensions | Height: 351 mm (13.7 in.), width: 482 mm (19.0 in.), depth: 804 mm (31.6 in), depth with cable management brackets installed: 836 mm (32.9 in), depth with Full-length I/O Book installed: 921 mm (36.2 in) |
Weight | Minimum configuration: 84.5 kg (186.3 lb), maximum: 110.0 kg (242.6 lb) |
The server is shipped with the following items:
- Rail kit
- Cable management brackets
- 2.8 m (9.18 ft) C13-C14 power cord (one for each power supply)
- Documentation flyer and safety/warranty/installation information
Standard models
This following table lists the standard models.
Withdrawn: All models are now withdrawn from marketing.
Model† | Intel Xeon** (Compute Book) |
Memory | RAID | Drive bays Drives |
Ethernet‡ (ML2 slot) |
I/O slots§ |
Power supplies |
---|---|---|---|---|---|---|---|
x3950 X6 models with E7 v4 processors and TruDDR4 memory | |||||||
6241-58x* | 4x E7-8860 v4 18C 2.2GHz 45M 140W |
8x 16GB (1866MHz)¤ |
1x M5210 | 4x 2.5" / 8 Open bay |
4x 1 GbE | 12 std 24 max |
4x 900W HS / 8 |
6241-78x* | 4x E7-8870 v4 20C 2.1GHz 50M 140W |
8x 16GB (1866MHz)¤ |
1x M5210 | 4x 2.5" / 8 Open bay |
4x 1 GbE | 12 std 24 max |
4x 900W HS / 8 |
6241-98x* | 4x E7-8890 v4 24C 2.2GHz 60M 165W |
8x 16GB (1866MHz)¤ |
1x M5210 | 4x 2.5" / 8 Open bay |
4x 1 GbE | 12 std 24 max |
4x 900W HS / 8 |
† x in the Machine Type Model (MTM) represents a region-specific letter (for example, the EMEA MTM is 6241-BAG, and the US MTM is 6241-BAU). Ask a Lenovo representative for specifics.
* Not available in North America
** Processor detail: Processor quantity and model, cores, core speed, L3 cache, and TDP.
‡ All models include one Intel I350-T4 ML2 Quad Port GbE Adapter (I350-AM4 based).
§ Models with 12 slots have two Primary I/O Books (each with four slots) and two Storage Books (each with two slots) standard.
For more information about the standard features of the server, see the Standard specification section.
SAP HANA Workload Optimized models
The Lenovo System x3950 X6 Workload Optimized Solutions for SAP HANA provide optimal solutions for SAP NetWeaver Business Warehouse, data mart, and SAP Business Suite, Powered by SAP HANA applications. Preconfigured workload optimized server models for SAP HANA applications are configured with up to 2 TB of memory and are upgradeable to support larger single node and scale-out cluster implementations.
The following table lists the Workload Optimized Solution models for SAP HANA.
Withdrawn: All models are now withdrawn from marketing.
Note: For CTO configurations of SAP HANA models, select base model 6241-AC4
Model | Intel Xeon (Compute Book) |
Memory | RAID | Drive bays Drives |
Ethernet | I/O slots |
Power supplies |
---|---|---|---|---|---|---|---|
x3950 X6 HANA models with E7 v4 processors and TruDDR4 memory - Standard models | |||||||
6241- 8Gx |
4x E7-8880 v4 22C 2.2GHz 55M 150W |
32x 16GB (1866MHz)¤ |
1x M5210 + upgrades* |
8x 2.5" bays 6x 1.2 TB SAS HDD 2x 400 GB S3710 SSD |
2x 4x1GbE ML2 2x Mellanox 10Gb* |
12 std 24 max |
8x 1400W HS / 8 |
6241- 8Hx |
4x E7-8880 v4 22C 2.2GHz 55M 150W |
32x 32GB (1866MHz)¤ |
2x M5210 + upgrades* |
16x 2.5" bays 12x 1.2 TB SAS HDD 4x 400 GB S3710 SSD |
2x 4x1GbE ML2 2x Mellanox 10Gb* |
12 std 24 max |
8x 1400W HS / 8 |
6241- 8Jx |
8x E7-8880 v4 22C 2.2GHz 55M 150W |
64x 32GB (1866MHz)¤ |
2x M5210 + upgrades* |
16x 2.5" bays 12x 1.2 TB SAS HDD 4x 400 GB S3710 SSD |
2x 4x1GbE ML2 2x Mellanox 10Gb* |
18 std 24 max |
8x 1400W HS / 8 |
x3950 X6 HANA models with E7 v4 processors and TruDDR4 memory - TopSeller models | |||||||
6241- ELU |
4x E7-8880 v4 22C 2.2GHz 55M 150W |
32x 16GB (1866MHz)¤ |
1x M5210 + upgrades* |
8x 2.5" bays 6x 1.2 TB SAS HDD 2x 400 GB S3710 SSD |
2x 4x1GbE ML2 2x Mellanox 10Gb* |
12 std 24 max |
8x 1400W HS / 8 |
* See the list of specific components below
Each of these HANA models include the following components (see the proceeding table for specifics):
- One or two ServeRAID M5210 controller (46C9110) with 2GB cache upgrade with flash backup (47C8664) plus Performance Accelerator (47C8710) and SSD Caching Enabler (47C8712)
- Six or 12x 1.2TB 10K 6Gbps SAS 2.5" G3HS HDD (00AJ146)
- Two or four Intel S3710 400GB Enterprise Performance SATA G3HS 2.5" SSDs (00YC325)
- Two Intel I350-T4 ML2 Quad Port GbE Adapter for System x (00D1998)
- Two Mellanox ConnectX-3 10 GbE Adapters (00D9690) plus four SFP+ SR Transceivers (46C3447)
- Models with 18 standard slots: Two X6 Half-length I/O Books (44X4049)
- Lenovo solution for SAP HANA media
Note: The operating system software is not included with the SAP HANA models. Operating system selection must be a separate line item included in order: SLES for SAP with standard or priority support. The SAP HANA Software is included, but the license is sold separately by SAP or an SAP business partner. VMware Enterprise Plus license sold separately. IBM Spectrum Scale (GPFS) is available from Lenovo separately.
For more information about the standard features of the server, see the Standard specification section.
Upgrading Compute Books
With the x3950 X6, machine type 6241, Lenovo supports upgrading the server processors by simply by replacing the Compute Books. The process to upgrade is made very simple because of the innovative book design of the x3850 X6.
Supported upgrades are:
- E7 v2 processors to E7 v4 processors (new DDR4 DIMMs required)
- E7 v3 processors with DDR3 to E7 v4 processors (new DDR4 DIMMs required)
- E7 v3 processors with DDR4 to E7 v4 processors (optionally keep existing memory)
Notes:
- Upgrades to E7 v4 processors are only supported with machine type 6241. If you want to upgrade an X6 server with machine type 3837, contact your local representative.
- eXFlash DIMMs (now withdrawn) are not supported with TruDDR4 memory; Only DDR3 memory is supported
- Intel Xeon E7 v4 processors require minimum firmware levels. Consult the documentation that is included with the Compute Books.
- Compute books with E7 v4 processors do not support DDR3 memory
- If you upgrade from E7 v3 processors with DDR4 to E7 v4 processors, you can transfer the 2133 MHz DDR4 memory DIMMs to the new compute books. If you also want to add additional memory to the E7 v4 compute book, it is supported to use either 2133 MHz or 2400 MHz DDR4 memory DIMMs. It is supported to mix 2133 MHz and 2400 MHz DIMMs in the same compute book.
Processor options
The x3950 X6 supports up to eight Intel Xeon E7 v4 processors. Compute books with E7 v3 or E7 v2 processors are now withdrawn from marketing. Processors are installed in Compute Books, one processor in each Compute Book. The following figure shows the components of the Compute Book:
- One processor
- A total of 24 DIMM slots, 12 on each side of the book
- Two hot-swap dual-motor fans that are mounted on the front of the book
The x3950 X6 supports four, six, or eight Compute Books. Other combinations are not supported.
Each Compute Book is installed in the front of the server, as shown in the following figure.
Figure 4. Compute Book
The following table shows the processor options, grouped as follows. Each option includes the processor installed in a Compute Book:
- E7-8800 v4 processors in Compute Books with TruDDR4 support
Note: Compute Books with E7-4800 processors are supported only in a four-socket x3850 X6 server and cannot be used in an x3950 X6 server.
The table also shows the maximum memory bus speed each processor supports plus which server models have each processor standard. If there is no corresponding where-used model for a particular processor, this processor is only available through CTO.
Part number Feature codes‡ |
Description (processor installed in a Compute Book) |
L3 cache |
QPI speed |
Memory support |
Memory bus speed (RAS / Performance)† |
HT | TB | Models where used |
---|---|---|---|---|---|---|---|---|
Intel Xeon E7-8800 v4 processors | ||||||||
00KH384 ATWZ / ATYF |
X6 Compute Book E7-8855 v4 14C 2.1GHz 35M 140W |
35 MB | 8 GHz | TruDDR4 | 1866 MHz / 1333 MHz |
Y | Y | - |
00WH322 ATX6 / ATXW |
X6 Compute Book E7-8860 v4 18C 2.2GHz 45M 140W |
45 MB | 9.6 GHz | TruDDR4 | 1866 MHz / 1600 MHz |
Y | Y | 58x |
00WH318 ATX5 / ATXV |
X6 Compute Book E7-8867 v4 18C 2.4GHz 45M 165W |
45 MB | 9.6 GHz | TruDDR4 | 1866 MHz / 1600 MHz |
Y | Y | - |
00WH326 ATX7 / ATXX |
X6 Compute Book E7-8870 v4 20C 2.1GHz 50M 140W |
50 MB | 9.6 GHz | TruDDR4 | 1866 MHz / 1600 MHz |
Y | Y | 78x |
00WH330 ATX8 / ATXY |
X6 Compute Book E7-8880 v4 22C 2.2GHz 55M 150W |
55 MB | 9.6 GHz | TruDDR4 | 1866 MHz / 1600 MHz |
Y | Y | HANA models |
00WH334 ATX9 / ATXZ |
X6 Compute Book E7-8890 v4 24C 2.2GHz 60M 165W |
60 MB | 9.6 GHz | TruDDR4 | 1866 MHz / 1600 MHz |
Y | Y | 98x |
00WH342 ATXB / ATY1 |
X6 Compute Book E7-8891 v4 10C 2.8GHz 60M 165W |
60 MB | 9.6 GHz | TruDDR4 | 1866 MHz / 1600 MHz |
Y | Y | - |
00WH346 ATXC / ATY2 |
X6 Compute Book E7-8893 v4 4C 3.2GHz 60M 140W |
60 MB | 9.6 GHz | TruDDR4 | 1866 MHz / 1600 MHz |
Y | Y | - |
00YG935 AVR6 / AVR7 |
X6 Compute Book E7-8894 v4 24C 2.4GHz 60M 165W |
60 MB | 9.6 GHz | TruDDR4 | 1866 MHz / 1600 MHz |
Y | Y | - |
‡ The first feature code is for the first Compute Book. The second feature code is for all additional Compute Books
† The processors support two memory modes, RAS mode (also known as lockstep mode) and Performance mode (also known as independent mode). In Performance mode, the SMI2 link operates at twice the memory bus speed shown.
Memory options
The x3950 X6 (6241) supports either DDR3 or TruDDR4 memory, depending on the Compute Books used in the server.
Lenovo TruDDR4 Memory uses the highest quality components that are sourced from Tier 1 DRAM suppliers and only memory that meets the strict requirements of Lenovo is selected. It is compatibility tested and tuned to maximize performance and reliability. TruDDR4 Memory has a unique signature that is programmed into the DIMM that enables System x® servers to verify whether the memory that is installed is qualified or supported by Lenovo. Because TruDDR4 Memory is authenticated, certain extended memory performance features can be enabled to extend performance over industry standards.
Lenovo DDR3 memory is compatibility tested and tuned for optimal System x performance and throughput. Lenovo memory specifications are integrated into the light path diagnostics for immediate system performance feedback and optimum system uptime.
From a service and support standpoint, Lenovo TruDDR4 and DDR3 memory automatically assumes the system warranty, and Lenovo provides service and support worldwide.
The x3950 X6 supports TruDDR4 memory operating at speeds up to 1866 MHz and DDR3 memory at speeds up to 1600 MHz. Note that even though supported TruDDR4 DIMMs are rated at 2400 MHz or 2133 MHz, when used in the x3950 X6, they operate at speeds up to 1866 MHz.
The x3950 X6 supports up to 192 DIMMs when all processors are installed, 24 DIMMs per processor. Each processor has four memory channels that are implemented using Scalable Memory Interface generation 2 (SMI2) chips, and the server implements three DIMMs per channel. The processor and the corresponding memory DIMM slots are on the Compute Book.
The following table lists the memory options that are available for x3950 X6.
Part number | Feature code | Description | Maximum supported x3950 X6 |
Standard models where used |
---|---|---|---|---|
2400 MHz TruDDR4 RDIMMs and LRDIMMs (for use with E7 v4 processors; also supported with E7 v3) | ||||
46W0821 | ATC8 | 8GB TruDDR4 Memory (1Rx4, 1.2V) PC4-19200 CL17 2400MHz LP RDIMM |
192 (24 per CPU) | |
46W0829 | ATCA | 16GB TruDDR4 Memory (2Rx4, 1.2V) PC4-19200 CL17 2400MHz LP RDIMM |
192 (24 per CPU) | All other v4 models |
46W0833 | ATCB | 32GB TruDDR4 Memory (2Rx4, 1.2V) PC4-19200 CL17 2400MHz LP RDIMM |
192 (24 per CPU) | 8Hx, 8Jx |
46W0841 | ATGG | 64GB TruDDR4 Memory (4Rx4, 1.2V) PC4-19200 CL17 2400MHz LP LRDIMM |
192 (24 per CPU) | - |
00YG941 | B0MV | 128GB TruDDR4 Memory (8Rx4 1.2V) PC4-2400-R 2400MHz 3DS RDIMM |
192 (24 per CPU) | - |
The following rules apply when selecting the memory configuration:
- The server supports RDIMMs and LRDIMMs.
- DDR4 Compute Books support mixing 2133 MHz and 2400 MHz DDR4 memory. (Note: 2133 MHz DIMMs are now withdrawn)
- Mixing different types of memory (combinations of RDIMMs, LRDIMMs, and 3DS RDIMMs) is not supported.
- Mixing different generations of memory (DDR3 and TruDDR4) is not supported
- The maximum number of ranks per one memory channel is six with RDIMMs, 12 with LRDIMMs, or 24 with 3DS RDIMMs.
- In RAS (lockstep) mode, DIMMs must be installed in a pair.
- The maximum quantity of DIMMs that can be installed in the server depends on the number of processors, DIMM type, rank, and operating voltage, as shown in the "Max. qty supported" row in the following table.
- All DIMMs in the server operate at the same speed, which is determined as the lowest value of one of the following options:
- Memory speed that is supported by the specific processor.
- Lowest of maximum operating speeds for selected memory configuration that depends on rated speed, operating voltage, and quantity of DIMMs per channel, as shown under "Maximum operating speed" section in the following table.
The following table shows the characteristics of the supported DIMMs. Tables cells that are highlighted with a gray background indicate that the server supports higher memory frequencies or larger memory capacity (or both) than the Intel processor specification defines.
Memory speed: In performance mode, memory channels operate independently, and the SMI2 link operates at twice the DDR3 speed. In RAS mode, two channels operate synchronously, and the SMI2 link operates at the DDR3 speed.
Specification | RDIMMs | LRDIMMs | 3DS RDIMMs | |
Rank | Single rank | Dual rank | Quad rank | Octo rank |
Part numbers | 46W0821 (8 GB) | 46W0829 (16 GB) 46W0833 (32 GB) |
46W0841 (64 GB) | 00YG941 (128 GB) |
Rated speed | 2400 MHz | 2400 MHz | 2400 MHz | 2400 MHz |
Rated voltage | 1.2 V | 1.2 V | 1.2 V | 1.2 V |
Operating voltage | 1.2 V | 1.2 V | 1.2 V | 1.2 V |
Maximum quantity* | 192 | 192 | 192 | 192 |
Largest DIMM | 8 GB | 32 GB | 64 GB | 128 GB |
Max memory capacity | 1.5 TB | 6 TB | 12 TB | 24 TB |
Maximum operating speed - Performance mode (2:1 mode - SMI2 link operates at twice the speed shown) | ||||
1 DIMM per channel | 1600 MHz | 1600 MHz | 1600 MHz | 1600 MHz |
2 DIMMs per channel | 1600 MHz | 1600 MHz | 1600 MHz | 1600 MHz |
3 DIMMs per channel | 1600 MHz | 1600 MHz† | 1600 MHz | 1600 MHz |
Maximum operating speed - RAS mode (1:1 mode - SMI2 link operates at the speed shown) | ||||
1 DIMM per channel | 1866 MHz | 1866 MHz | 1866 MHz | 1866 MHz |
2 DIMMs per channel | 1866 MHz | 1866 MHz | 1866 MHz | 1866 MHz |
3 DIMMs per channel | 1600 MHz | 1600 MHz† | 1600 MHz | 1600 MHz |
* Maximum quantity supported is shown for all processors that are installed
† This speed is above the Intel standard and is achieved only when Lenovo TruDDR4 memory is used
The following memory protection technologies are supported:
- ECC
- Chipkill (for x4-based memory DIMMs)
- Redundant bit steering (Double Device Data Correction)
- Memory mirroring
- Memory rank sparing
Chipkill and Redundant Bit Steering are supported in RAS mode. Chipkill is supported in Performance mode.
If memory mirroring is used, DIMMs must be installed in pairs for Performance mode (minimum of one pair per each processor) and quads for RAS mode. DIMMs in the pair/quad must be identical in type and size.
If memory rank sparing is used, then a minimum of two single-rank or dual-rank DIMMs must be installed per populated channel (the DIMMs do not need being identical). In rank sparing mode, one rank of a DIMM in each populated channel is reserved as spare memory. The size of a rank varies depending on the DIMMs that are installed.
Internal storage
The server supports 1.8-inch solid-state drives in the SSD units and 2.5-inch SSDs and HDDs. Drives are installed in the Storage Book. The x3950 X6 has two Storage Books.
Each Storage Book supports the following configurations:
- 4x 2.5-inch hot-swap drive bays
- 8x 2.5-inch hot-swap drive bays
- 4x 2.5-inch hot-swap drive bays + 8x 1.8-inch hot-swap SSD bays
- 8x 1.8-inch hot-swap SSD bays
- 16x 1.8-inch hot-swap SSD bays
- 4x 2.5-inch PCIe NVMe SSDs
- 2x 2.5-inch PCIe NVMe SSDs + 8x 1.8-inch HDD hot-swap drives
- 2x 2.5-inch PCIe NVMe SSDs + 4x 2.5-inch HDD hot-swap drives
The following figure shows these configurations.
Figure 5. Internal drive configurations
Backplanes
All standard models ship with four 2.5-inch SAS/SATA hot-swap hard disk drive bays. The following table shows the internal storage expansion options that are available.
Table 7. Internal storage expansion options
Part number |
Feature code |
Description | Maximum supported |
44X4104 | A4A6 | 4x 2.5" HS 12Gb SAS HDD Backplane | 4 |
44X4106* | A4A7 | 8x 1.8" HS 12Gb SAS HDD Backplane | 4 |
44X4108 | A4A8 | 1x4 2.5-inch NVMe PCIe Gen3 SSD Backplane | 2 |
* Withdrawn from marketing
The backplanes are connected to one or two RAID controllers or HBAs depending on the number and type of backplane that is installed. The adapters are installed in PCIe slots in the Storage Book, as shown in the following figure.
Figure 6. Storage Book
The following table shows the backplanes that are required per Storage Book and the number of controllers that are required. Note that the table shows the exact number of controllers supported for each drive/backplane configuration, no more, no fewer.
Drive combination | Backplanes required | Number of controllers supported |
4x 2.5-inch hot-swap drive bays | 1x 4x 2.5" HS 12Gb SAS HDD Backplane, 44X4104 | 1 |
8x 2.5-inch hot-swap drive bays | 2x 4x 2.5" HS 12Gb SAS HDD Backplane, 44X4104 | 1 |
4x 2.5-inch hot-swap drive bays + 8x 1.8-inch hot-swap SSD bays |
1x 4x 2.5" HS 12Gb SAS HDD Backplane, 44X4104 1x 8x 1.8" HS 12Gb SAS HDD Backplane, 44X4106 |
2 |
8x 1.8-inch hot-swap SSD bays | 1x 8x 1.8" HS 12Gb SAS HDD Backplane, 44X4106 | 1 |
16x 1.8-inch hot-swap SSD bays | 2x 8x 1.8" HS 12Gb SAS HDD Backplane, 44X4106 | 2 |
4x 2.5-inch NVMe | 1x 4x 2.5-inch NVMe PCIe SSD Backplane, 44X4108 | 1 or 2* |
2x 2.5-inch NVMe + 4x 2.5-inch HDD/SSD |
1x 4x 2.5-inch NVMe PCIe SSD Backplane, 44X4108 1x 4x 2.5" HS 12Gb SAS HDD Backplane, 44X4104 |
2 |
2x 2.5-inch NVMe + 8x 1.8-inch SSD |
1x 4x 2.5-inch NVMe PCIe SSD Backplane, 44X4108 1x 8x 1.8" HS 12Gb SAS HDD Backplane, 44X4106 |
2 |
* The number of controllers required is dependent on the number of drives installed: 1 or 2 drives requires one controller, and 3 or 4 drives requires two controllers.
Controllers for internal storage
The following table lists the RAID controllers, HBAs, and additional hardware and feature upgrades that are used for internal disk storage. The adapters are installed in slots in the Storage Book.
Part number |
Feature code |
Description | Maximum supported (slots) |
Models where used |
---|---|---|---|---|
46C9110 | A3YZ | ServeRAID M5210 SAS/SATA Controller | 4 (11, 12, 43, 44) | All models |
47C8675 | A3YY | N2215 SAS/SATA HBA | 4 (11, 12, 43, 44) | - |
00ML997 | AS95 | NVMe PCIe SSD Extender Adapter | 4 (11, 12, 43, 44) | - |
Hardware upgrades for the ServeRAID M5210 | ||||
47C8656 | A3Z0 | ServeRAID M5200 Series 1GB Cache/RAID 5 Upgrade | 4 | - |
47C8660 | A3Z1 | ServeRAID M5200 Series 1GB Flash/RAID 5 Upgrade | 4 | - |
47C8664 | A3Z2 | ServeRAID M5200 Series 2GB Flash/RAID 5 Upgrade | 4 | - |
47C8668 | A3Z3 | ServeRAID M5200 Series 4GB Flash/RAID 5 Upgrade | ||
Features on Demand upgrades for the ServeRAID M5210 | ||||
47C8708 | A3Z6 | ServeRAID M5200 Series Zero Cache/RAID 5 Upgrade | 1 / 2† | - |
47C8706 | A3Z5 | ServeRAID M5200 Series RAID 6 Upgrade | 1 / 2†* | - |
47C8710 | A3Z7 | ServeRAID M5200 Series Performance Accelerator | 1 / 2†* | - |
47C8712 | A3Z8 | ServeRAID M5200 Series SSD Caching Enabler | 1 / 2†* | - |
† Only one FoD key is required if the x3950 X6 is configured as a single image 8-socket server. If you partition the server into two four-socket servers, then two FoD keys are required.
* These M5210 features upgrades require a cache memory upgrade (47C8656, 47C8660, or 47C8664).
The following table compares the features of the supported controllers.
Feature | ServeRAID M5210 | N2215 | NVMe Extender |
---|---|---|---|
Adapter type | RAID controller | SAS HBA | PCIe Extender |
Part number | 46C9110 | 47C8675 | 00ML997 |
Form factor | PCIe low profile | PCIe low profile | PCIe low profile |
Controller chip | LSI SAS3108 | LSI SAS3008 | None |
Host interface | PCIe 3.0 x8 | PCIe 3.0 x8 | PCIe 3.0 x8 |
Port interface | 12 Gbps SAS | 12 Gbps SAS | PCIe NVMe |
Number of ports | 8 | 8 | 2 |
Port connectors | 2x Mini-SAS HD x4 (SFF-8643) |
2x Mini-SAS HD x4 (SFF-8643) |
OCuLink |
Drive interface | SAS, SATA | SAS, SATA | NVMe |
Drive type | HDD, SSD, SED | HDD, SSD | SSD |
Hot-swap drives | Yes | Yes | Yes |
Max devices | 240 | 1024 | 2 |
RAID levels | 0/1/10; Optional 5/50 (RAID 5 FoD, 47C8708, or cache upgrades) Optional 6/60 (47C8706) |
None | None |
JBOD mode | Yes (without cache) | Yes | Yes |
Cache | 1 GB no backup (47C8656) 1 GB flash backup (47C8660) 2 GB flash backup (47C8664) 4 GB flash backup (47C8668) |
None | None |
CacheVault cache protection | Optional | None | None |
Performance Accelerator (FastPath) | Optional (47C8710) | No | No |
SSD Caching (CacheCade Pro 2.0) | Optional (47C8712) | No | No |
SED support (SafeStore) |
Yes (with RAID 5 FoD upgrade |
No | No |
For more information, see the list of Lenovo Press Product Guides in the RAID adapters category:
https://lenovopress.com/servers/options/raid
The NVMe PCIe SSD Extender Adapter is a PCIe adapter that simply routes the PCIe 3.0 x8 signal from the slot in the Storage Book, splits the signal to two x4 links, and routes those via cables to the drive backplane. The extender adapter is shown in the following figure.
Figure 7. NVMe PCIe SSD Extender Adapter
One adapter is required for every two drives installed in the Storage Book. Since there are only two PCIe slots in the Compute Book, only two adapters can be installed and therefore only four NVMe drives can be installed in a Storage Book.
Internal drive options
The following tables list the hard disk drive and solid-state drive options for the internal disk storage of the server.
- Table 11: 2.5-inch hot-swap 12 Gb SAS HDDs
- Table 12: 2.5-inch hot-swap 6 Gb SAS/SATA HDDs
- Table 13: 2.5-inch hot-swap 12 Gb SAS SSDs
- Table 14: 2.5-inch hot-swap 6 Gb SAS/SATA SSDs
- Table 15: 2.5-inch NVMe SSDs
Part number | Feature | Description | Maximum supported |
---|---|---|---|
2.5-inch hot-swap HDDs - 12 Gb SAS 10K | |||
00WG685 | AT89 | 300GB 10K 12Gbps SAS 2.5" G3HS HDD | 16 |
00WG690 | AT8A | 600GB 10K 12Gbps SAS 2.5" G3HS HDD | 16 |
00WG695 | AT8B | 900GB 10K 12Gbps SAS 2.5" G3HS HDD | 16 |
00WG700 | AT8C | 1.2TB 10K 12Gbps SAS 2.5" G3HS HDD | 16 |
00NA271 | ASBM | 1.8TB 10K 12Gbps SAS 2.5" G3HS 512e HDD | 16 |
2.5-inch hot-swap HDDs - 12 Gb SAS 15K | |||
00WG660 | AT84 | 300GB 15K 12Gbps SAS 2.5" G3HS HDD | 16 |
00WG665 | AT85 | 600GB 15K 12Gbps SAS 2.5" G3HS HDD | 16 |
01GV035 | AVKU | 900GB 15K 12Gbps SAS 2.5" G3HS 512e HDD | 16 |
2.5-inch hot-swap HDDs - 12 Gb NL SAS | |||
00NA491 | AT7Z | 1TB 7.2K 12Gbps NL SAS 2.5" G3HS HDD | 16 |
00NA496 | AT80 | 2TB 7.2K 12Gbps NL SAS 2.5" G3HS 512e HDD | 16 |
2.5-inch hot-swap SED HDDs - 12 Gb SAS 10K | |||
00WG705 | AT8D | 300GB 10K 12Gbps SAS 2.5" G3HS SED | 16 |
00WG710 | AT8E | 600GB 10K 12Gbps SAS 2.5" G3HS SED | 16 |
00WG715 | AT8F | 900GB 10K 12Gbps SAS 2.5" G3HS SED | 16 |
00WG720 | AT8G | 1.2TB 10K 12Gbps SAS 2.5" G3HS SED | 16 |
Part number | Feature | Description | Maximum supported |
---|---|---|---|
2.5-inch hot-swap HDDs - 6 Gb SAS 10K | |||
01GV070 | B0YT | 2.4TB 10K 12Gbps SAS 2.5" G3HS 512e HDD | 16 |
2.5-inch hot-swap HDDs - 6 Gb NL SATA | |||
00AJ141 | A4TX | 1TB 7.2K 6Gbps NL SATA 2.5" G3HS HDD | 16 |
00NA526 | AT81 | 2TB 7.2K 6Gbps NL SATA 2.5" G3HS 512e HDD | 16 |
Part number | Feature | Description | Maximum supported |
---|---|---|---|
2.5-inch hot-swap SSDs - 12 Gb SAS - Enterprise Capacity | |||
01GR786 | AVKV | PM1633a 3.84TB Enterprise Capacity 12Gb SAS G3HS 2.5" SSD | 16 |
01GR771 | AUEJ | PM1633a 7.68TB Enterprise Capacity 12Gb SAS G3HS 2.5" SSD | 16 |
2.5-inch hot-swap SSDs - 12 Gb SAS - Enterprise Performance (10+ DWPD) | |||
01GV711 | AVL0 | 400GB Enterprise Performance 12G SAS G3HS 2.5" SSD | 16 |
01GV716 | AVL1 | 800GB Enterprise Performance 12G SAS G3HS 2.5" SSD | 16 |
01GV721 | AVL2 | 1.6TB Enterprise Performance 12G SAS G3HS 2.5" SSD | 16 |
2.5-inch hot-swap SSDs - 12 Gb SAS - Enterprise Mainstream (3-5 DWPD) | |||
01GV761 | AWEY | PM1635a 400GB Enterprise Mainstream 12Gb SAS G3HS 2.5" SSD | 16 |
01GV766 | AWEZ | PM1635a 800GB Enterprise Mainstream 12Gb SAS G3HS 2.5" SSD | 16 |
01GV771 | AWF0 | PM1635a 1.6TB Enterprise Mainstream 12Gb SAS G3HS 2.5" SSD | 16 |
Part number | Feature | Description | Maximum supported |
---|---|---|---|
2.5-inch hot-swap SSDs - 6 Gb SATA - Enterprise Mainstream (3-5 DWPD) | |||
7SD7A05713 | B10B | Intel S4600 480GB Enterprise Mainstream SATA G3HS 2.5" SSD | 16 |
01GV863 | AXFZ | 5100 3.84TB Enterprise Mainstream SATA G3HS 2.5" SSD | 16 |
2.5-inch hot-swap SSDs - 6 Gb SATA - Enterprise Entry (<3 DWPD) | |||
7SD7A05732 | B0Z8 | Intel S4500 240GB Enterprise Entry SATA G3HS 2.5" SSD | 16 |
7SD7A05731 | B0Z9 | Intel S4500 480GB Enterprise Entry SATA G3HS 2.5" SSD | 16 |
7SD7A05730 | B0ZA | Intel S4500 960GB Enterprise Entry SATA G3HS 2.5" SSD | 16 |
4XB7A08493 | B0ZB | Intel S4500 1.92TB Enterprise Entry SATA G3HS 2.5" SSD | 16 |
4XB7A08494 | B0ZC | Intel S4500 3.84TB Enterprise Entry SATA G3HS 2.5" SSD | 16 |
01GR836 | AVHP | PM863a 240GB Enterprise Entry SATA G3HS 2.5" SSD | 16 |
01GR846 | AVHR | PM863a 960GB Enterprise Entry SATA G3HS 2.5" SSD | 16 |
01GR711 | AUE7 | 1.92TB Enterprise Entry SATA G3HS 2.5" SSD | 16 |
Part number | Feature | Description | Maximum supported |
---|---|---|---|
2.5-inch SSDs - NVMe - Enterprise Mainstream (3-5 DWPD) | |||
7SD7A05767 | B11M | Intel P4600 1.6TB NVMe 2.5" Enterprise Mainstream PCIe SSD | 8 |
7SD7A05766 | B11N | Intel P4600 3.2TB NVMe 2.5" Enterprise Mainstream PCIe SSD | 8 |
2.5-inch SSDs - NVMe - Enterprise Entry (<3 DWPD) | |||
01GT715 | AVPP | PM963 3.84TB NVMe 2.5" Enterprise Value PCIe SSD | 8 |
4XB7A08539 | B1JK | Intel P4500 4.0TB NVMe 2.5" Enterprise Entry PCIe SSD | 8 |
Internal backup units
The server does not support internal tape drive options.
Optical drives
The server does not support an internal optical drive option, however, you can connect an external USB optical drive. See http://support.lenovo.com/en/documents/pd011281 for information about available external optical drives from Lenovo.
I/O expansion options
The server supports up to 22 PCIe slots plus two dedicated Mezzanine LOM slots (24 total) as follows:
- In each of the two Storage Books (standard in all models): Two PCIe 3.0 x8 slots for supported internal RAID controllers and SAS HBAs
- In each of the two Primary I/O Books (standard in all models):
- Two PCIe 3.0 x16 slots (x16-wired), half length, full height, up to 75 W of power
- One PCIe 3.0 x16 (x8-wired), half length, full height, up to 75 W of power
- One mezzanine LOM 2 (ML2) slot for network adapters with the new ML2 form factor (PCIe 3.0 x8)
- Four optional I/O Books, each with three slots, all full height. Optional I/O Books are hot-swap capable.
The following figure shows the Primary I/O Book with the air baffle raised to show the internals.
Figure 8. Primary I/O Book
Optional I/O Books can be either of:
- Half-length I/O Book:
- Two PCIe 3.0 x8 slots (x8 wired)
- One PCIe 3.0 x16 slot (x16 wired)
- Full-length I/O Book:
- Two PCIe 3.0 x16 (x16 wired)
- One PCIe 2.0 x8 slot (x4 wired)
Hot-swap support
In order for an I/O Book to be hot-swappable, all adapters that are installed in the book must support hot-swap and the operating system must also support hot-swap. These operating systems support hot-swap:
- Windows Server 2008 R2
- Windows Server 2012
- Windows Server 2012 R2
The adapters listed in the following table support hot-swap.
Part number | Feature code | Description |
00D8540* | A4XH | Emulex Dual Port 10GbE SFP+ VFA IIIr for System x* |
49Y7960 | A2EC | Intel X520 Dual Port 10GbE SFP+ Adapter for System x |
49Y7970 | A2ED | Intel X540-T2 Dual Port 10GBaseT Adapter for System x |
00AG500 | A56K | Intel I350-F1 1xGbE Fiber Adapter for System x |
00AG510 | A56L | Intel I350-T2 2xGbE BaseT Adapter for System x |
00AG520 | A56M | Intel I350-T4 4xGbE BaseT Adapter for System x |
* Hot-swap is only supported when the adapter is in pNIC mode. Hot-swap is not supported in either vNIC mode (Virtual Fabric mode or Switch Independent mode).
Optional I/O books
The use of two Optional I/O Books requires six processors to be installed. The usage of all four Optional I/O Books requires all eight processors to be installed.
The following table shows the ordering information for the optional I/O Books.
Table 17. I/O Book options
Part number |
Feature code |
Description | Maximum supported x3950 X6 |
44X4049 | A4A2 | X6 Half-Length I/O Book | 4 |
44X4051 | A4A3* | X6 Full-Length I/O Book | 4 |
* The Full-length I/O Book can be ordered only as an option. It is not available through CTO because the Full-length I/O Book cannot be shipped installed in the server
The following figure shows the two optional I/O Books: the Half-length I/O Book and the Full-length I/O Book.
Figure 9. Half-length I/O Book and the Full-length I/O Book
The following figure shows the Half-length I/O Book.
Figure 10. Half-length I/O Book
Each slot in the Half-length I/O Book and the Full-length I/O Book supplies up to 75 W of power.
The Full-length I/O Book also includes two auxiliary power connectors. With the usage of these connectors and the supplied power cords, the I/O book supports one double-wide adapter up to 300 W. The auxiliary power connectors are as follows:
- One 2x4 power connector, which supplies up to 150 W of additional power to the adapter
- One 2x3 power connector, which supplies up to 75 W of additional power to the adapter
The combined power consumption of all the adapters that are installed in the Full-length I/O Book cannot exceed 300 W.
Note: The 2x3 connector is intended to be used only when one adapter is installed in the first x16 slot (the up-most slot in the following figure), either requiring 225 W or 300 W of power. The location of the 2x3 connector prevents an adapter from being installed in the other x16 slot.
Figure 11. Full-length I/O Book
The Half-length I/O Book installs flush with the Primary I/O Book at the rear of the server. The Full-length I/O Book, when installed, adds a 99 mm (3.9 in.) mechanical extension to the base length dimension of the chassis.
The following figure shows a Full-length I/O Book and a Half-length I/O Book installed in the server.
Figure 12. Optional I/O Books that are installed (x3850 X6 shown)
Network adapters
The server supports ML2 adapters that are installed in the two ML2 slots, one in each Primary I/O Book. These ML2 slots support adapters with either two 10 Gb ports or four Gigabit ports and supports direct connectivity to the IMM2 service processor for out-of-band systems management.
As listed in Table 2, all standard models of the x3950 X6 include an Intel I350-T4 ML2 Quad Port GbE Adapter (I350-AM4 based).
The Intel I350-T4 ML2 Quad Port GbE Adapter has the following specifications:
- Quad-port 1 Gb Ethernet connectivity
- Intel I350-AM4 ASIC
- Four RJ45 ports for copper cables
For more information about this adapter, see the Lenovo Press Product Guide found at the following address:
http://lenovopress.com/tips1155
The following table lists the supported ML2 adapters. The following table lists the supported ML2 adapters. ML2 adapters are installed only in the ML2 slots (slot 10 and 42 as show in the Slot locations section).
Part number | Feature code |
Description | Maximum supported (slot #) |
---|---|---|---|
25 Gb Ethernet | |||
00MN990* | ATZR | Mellanox ConnectX-4 Lx ML2 1x25GbE SFP28 Adapter | 2* (10, 42) |
10 Gb Ethernet | |||
00D2026 | A40S | Broadcom NetXtreme II ML2 Dual Port 10GbaseT | 2 (10, 42) |
00D2028 | A40T | Broadcom NetXtreme II ML2 Dual Port 10GbE SFP+ | 2 (10, 42) |
00AG560 | AT7U | Emulex VFA5.2 ML2 Dual Port 10GbE SFP+ Adapter | 2 (10, 42) |
01CV770 | AU7Z | Emulex VFA5.2 ML2 2x10 GbE SFP+ Adapter and FCoE/iSCSI SW | 2 (10, 42) |
00D1994 | A40P | Intel X540 ML2 Dual Port 10GbaseT Adapter | 2 (10, 42) |
00JY940* | ATRH | Intel X710-DA2 ML2 2x10GbE SFP+ Adapter | 2* (10, 42) |
94Y5200 | AS74 | Intel X710 ML2 4x10GbE SFP+ Adapter | 2 (10, 42) |
Gigabit Ethernet | |||
00D1998 | A40R | Intel I350-T4 ML2 Quad Port GbE Adapter | 2 (10, 42) |
InfiniBand | |||
00FP650 | A5RK | Mellanox ConnectX-3 Pro ML2 2x40GbE/FDR VPI Adapter | 2 (10, 42) |
* Not supported in servers with E7 v2 compute books
The server also supports various other Ethernet, InfiniBand and Omni-Path network adapters, as listed in the following table. The maximum quantity listed is for configurations with all processors and I/O books installed.
The maximum supported column also indicates which slots each adapter is supported in. For slot locations see the Slot locations section.
Part number | Feature code |
Description | Maximum supported (slot #) |
---|---|---|---|
Omni-Path Architecture (OPA) | |||
00WE027 | AU0B | Intel OPA 100 Series Single-port PCIe 3.0 x16 HFA | 6 (7-9, 39-41) |
00WE023 | AU0A | Intel OPA 100 Series Single-port PCIe 3.0 x8 HFA | 4 (7,9,39,41) |
100 Gb Ethernet | |||
00MM960* | ATRP | Mellanox ConnectX-4 2x100GbE/EDR IB QSFP28 VPI Adapter | 8* (1, 4, 7, 9, 33, 36, 39, 41) |
40 Gb Ethernet | |||
00MM950* | ATRN | Mellanox ConnectX-4 Lx 1x40GbE QSFP+ Adapter | 18* (1-9, 33-41) |
00D9550 | A3PN | Mellanox ConnectX-3 40GbE / FDR IB VPI Adapter | 18 (1-9, 33-41) |
25 Gb Ethernet | |||
01GR250 | AUAJ | Mellanox ConnectX-4 Lx 2x25GbE SFP28 Adapter | 18 (1-9, 33-41) |
10 Gb Ethernet | |||
94Y5180 | A4Z6 | Broadcom NetXtreme Dual Port 10GbE SFP+ Adapter | 18 (1-9, 33-41) |
44T1370 | A5GZ | Broadcom NetXtreme 2x10GbE BaseT Adapter | 18 (1-9, 33-41) |
00AG570 | AT7S | Emulex VFA5.2 2x10 GbE SFP+ PCIe Adapter | 18 (1-9, 33-41) |
00AG580 | AT7T | Emulex VFA5.2 2x10 GbE SFP+ Adapter and FCoE/iSCSI SW | 18 (1-9, 33-41) |
00D8540 | A4M9 | Emulex Dual Port 10GbE SFP+ VFA III-R | 18 (1-9, 33-41) |
49Y7960 | A2EC | Intel X520 Dual Port 10GbE SFP+ Adapter | 18 (1-9, 33-41) |
49Y7970 | A2ED | Intel X540-T2 Dual Port 10GBaseT Adapter | 18 (1-9, 33-41) |
00MM850† | ATRY | Intel X550-T1 Single Port 10GBase-T Adapter | 18† (1-9, 33-41) |
00MM860* | ATPX | Intel X550-T2 Dual Port 10GBase-T Adapter | 18* (1-9, 33-41) |
01DA900 | AU2Y | Intel X710-DA2 2x10GbE SFP+ Adapter | 18 (1-9, 33-41) |
00D9690 | A3PM | Mellanox ConnectX-3 10 GbE Adapter | 18 (1-9, 33-41) |
Gigabit Ethernet | |||
90Y9370 | A2V4 | Broadcom NetXtreme I Dual Port GbE Adapter | 18 (1-9, 33-41) |
90Y9352 | A2V3 | Broadcom NetXtreme I Quad Port GbE Adapter | 18 (1-9, 33-41) |
49Y4230 | 5767 | Intel Ethernet Dual Port Server Adapter I340-T2 | 18 (1-9, 33-41) |
49Y4240 | 5768 | Intel Ethernet Quad Port Server Adapter I340-T4 | 18 (1-9, 33-41) |
00AG500 | A56K | Intel I350-F1 1xGbE Fiber Adapter | 18 (1-9, 33-41) |
00AG510 | A56L | Intel I350-T2 2xGbE BaseT Adapter | 18 (1-9, 33-41) |
00AG520 | A56M | Intel I350-T4 4xGbE BaseT Adapter | 18 (1-9, 33-41) |
InfiniBand | |||
00D9550 | A3PN | Mellanox ConnectX-3 40GbE / FDR IB VPI Adapter | 18 (1-9, 33-41) |
00KH924 | ASWQ | Mellanox ConnectX-4 EDR IB VPI Single-port x16 PCIe 3.0 HCA | 8 (1,4,7,9, 33,36,39,41) |
* Not supported in servers with E7 v2 compute books
† Only supported in servers with E7 v4 compute books
For more information, including supported transceivers and cables, see the list of Lenovo Press Product Guides in the Ethernet Adapters category and the InfiniBand & Omni-Path Adapters category.
SAS adapters for external storage
The following table lists the SAS HBAs and RAID adapters that are supported by the x3850 X6. The maximum quantity listed is for configurations with all processors and I/O books installed. The maximum supported column also indicates which slots each adapter is supported in. For slot locations see the Slot locations section.
Part number | Feature code |
Description | Maximum supported (slot #) |
SAS HBAs | |||
00AE912 | A5M0 | N2225 SAS/SATA HBA | 18 (1-9, 33-41) |
00AE916 | A5M1 | N2226 SAS/SATA HBA | 10 (1, 4, 7, 8, 9, 33, 36, 39, 40, 41) |
RAID adapters | |||
00AE938 | A5ND | ServeRAID M5225-2GB SAS/SATA Controller | 6 (7, 8, 9, 39, 40, 41) |
Features on Demand upgrades for the M5225 (1 per server) | |||
47C8706 | A3Z5 | ServeRAID M5200 Series RAID 6 Upgrade-FoD | 1 |
47C8710 | A3Z7 | ServeRAID M5200 Series Performance Accelerator-FoD | 1 |
47C8712 | A3Z8 | ServeRAID M5200 Series SSD Caching Enabler-FoD | 1 |
The following table compares the specifications of the external SAS HBAs and RAID adapters.
Feature | N2225 | N2226 | ServeRAID M5225 |
---|---|---|---|
Adapter type | SAS HBA | SAS HBA | RAID adapter |
Part number | 00AE912 | 00AE916 | 00AE938 |
Form factor | Low profile | Low profile | Low profile |
Controller chip | LSI SAS3008 | LSI SAS3008 | LSI SAS3108 |
Host interface | PCIe 3.0 x8 | PCIe 3.0 x8 | PCIe 3.0 x8 |
Port interface | 12 Gbps SAS | 12 Gbps SAS | 12 Gbps SAS |
Number of external ports | 8 | 16 | 8 |
External port connectors | 2x Mini-SAS HD (SFF-8644) | 4x Mini-SAS HD (SFF-8644) | 2x Mini-SAS HD (SFF-8644) |
Drive interface | SAS, SATA | SAS, SATA | SAS, SATA |
Drive type | HDD, SSD | HDD, SSD | HDD, SED, SSD |
Maximum number of devices | 1024 | 1024 | 240 |
RAID levels | None | None | 0/1/10/5/50; Optional 6/60 (47C8706) |
JBOD mode | Yes | Yes | No |
Cache | None | None | 2 GB (included) |
CacheVault cache protection | None | None | Flash (included) |
FastPath | None | None | Optional (47C8710) |
CacheCade Pro 2.0 | None | None | Optional (47C8712) |
Cache upgrade required: The ServeRAID M5120 SAS/SATA Controller ships standard without a cache. One of the available cache upgrades (81Y4487, 81Y4559, or 47C8670) is required for the M5120 adapter operations, and it must be purchased together with the controller.
For more information about the adapters, see these Lenovo Press Product Guides:
- N2125: http://lenovopress.com/tips1062
- N2225 & N2226: http://lenovopress.com/tips1175
- ServeRAID M5120: http://lenovopress.com/tips0858
- ServeRAID M5225: http://lenovopress.com/tips1258
Fibre Channel host bus adapters
The following table lists the Fibre Channel HBAs supported by the x3950 X6. The maximum quantity listed is for configurations with all processors and I/O books installed. The maximum supported column also indicates which slots each adapter is supported in. For slot locations see the Slot locations section.
Part number | Feature code |
Description | Maximum supported |
---|---|---|---|
Fibre Channel - 16 Gb (32 Gb ASIC) | |||
01CV830* | ATZU | Emulex 16Gb Gen6 FC Single-port HBA | 18* (1-9, 33-41) |
01CV840* | ATZV | Emulex 16Gb Gen6 FC Dual-port HBA | 18* (1-9, 33-41) |
01CV750* | ATZB | QLogic 16Gb Enhanced Gen5 FC Single-port HBA | 18* (1-9, 33-41) |
01CV760* | ATZC | QLogic 16Gb Enhanced Gen5 FC Dual-port HBA | 18* (1-9, 33-41) |
Fibre Channel - 16 Gb | |||
81Y1655 | A2W5 | Emulex 16Gb FC Single-port HBA | 18 (1-9, 33-41) |
81Y1662 | A2W6 | Emulex 16Gb FC Dual-port HBA | 18 (1-9, 33-41) |
00Y3337 | A3KW | QLogic 16Gb FC Single-port HBA | 18 (1-9, 33-41) |
00Y3341 | A3KX | QLogic 16Gb FC Dual-port HBA | 18 (1-9, 33-41) |
Fibre Channel - 8 Gb | |||
42D0485 | 3580 | Emulex 8 Gb FC Single-port HBA | 18 (1-9, 33-41) |
42D0494 | 3581 | Emulex 8 Gb FC Dual-port HBA | 18 (1-9, 33-41) |
42D0501 | 3578 | QLogic 8 Gb FC Single-port HBA | 18 (1-9, 33-41) |
42D0510 | 3579 | QLogic 8 Gb FC Dual-port HBA | 18 (1-9, 33-41) |
* Not supported in servers with E7 v2 compute books
For more information, see the list of Lenovo Press Product Guides in the Host bus adapters category:
https://lenovopress.com/servers/options/hba
PCIe Flash Storage adapters
All supported Flash Storage Adapters are now withdrawn from marketing.
GPU adapters and co-processors
The server supports the co-processors and graphics processing units (GPUs) that are listed in the following table. Each is installed in a Full-length I/O Book. No other adapter can be installed in the Full-length I/O Book. The Full-length I/O Book includes the necessary auxiliary power cables. The maximum supported column also indicates which slots each adapter is supported in. For slot locations see the Slot locations section.
Notes:
- These adapters are not available through CTO and cannot be shipped installed in the server because they are installed in the Full-length I/O Book, which extends beyond the rear of the chassis (see Figure 12 in the I/O expansion options). These adapters must be shipped separately from the server. Order the adapter and Full-length I/O Book as separate options.
- If an NVIDIA GPU is installed, the maximum system memory that can be installed is 1 TB, however, it is recommended you have less than 1 TB of memory installed. See https://support.lenovo.com/us/en/solutions/ht114952 for details.
Part number |
Feature code |
Description | Minimum system RAM |
Maximum supported (slot #) |
---|---|---|---|---|
90Y2495 | AU3W† | NVIDIA Quadro M6000 24GB GPU, PCIe (active) | 48 GB | 4 (1, 4, 33, 36) |
00YL378* | ATZF† | NVidia Quadro M5000 GPU, PCIe (active) | 16 GB | 4* (1, 4, 33, 36) |
* Not supported in servers with E7 v2 compute books
† Not available through CTO.
Power supplies
The x3950 X6 supports up to eight redundant power supplies. Standard models come with four power supplies (model dependent). The following table lists the power supplies.
Table 24. Power supplies
Part number | Feature code |
Description | Maximum supported x3950 X6 |
Standard models where used |
44X4150 | A54D | 1400W HE Redundant Power Supply for altitudes >5000 meters |
8 | All HANA models |
44X4152 | A54E | 1400W HE Redundant Power Supply | 8 | - |
44X4132 | A4R0 | 900W Power Supply | 8 | BAx, CAx, CCx |
88Y7433 | A2EA | 750W High Efficiency -48 V DC Power Supply | 8 | - |
An AC power supply ships standard with one 2.8 m C13 - C14 power cord.
Configuration rules are as follows:
- Power supplies must be in quads for the x3950 X6
- It is not recommended you mix the two 1400 W options (44X4152 for low altitude and 44X4150 for high altitude) as you will nullify the high-altitude capabilities of 44X4150.
- You cannot mix the AC power supplies with the DC power supply
- Use the Power Configurator to determine exactly what power your server needs:
https://support.lenovo.com/documents/LNVO-PWRCONF
Integrated virtualization
The server supports VMware ESXi that is installed on a USB memory key. The key is installed in a USB socket that is on the primary I/O book inside the server. The following table lists the virtualization options.
Table 25. Virtualization options
Part number | Feature code |
Description | Maximum supported† |
Blank USB keys | |||
00WH140 | ATRM | Blank USB Memory Key 4G SLC for VMware ESXi Downloads (4GB capacity) | 1 / 2 |
41Y8298 | A2G0 | Blank USB Memory Key for VMware ESXi Downloads (2GB capacity) | 1 / 2 |
USB keys preloaded with Lenovo custom image | |||
00ML235 | ASN7 | USB Memory Key for VMware ESXi 5.5 Update 2 | 1 / 2 |
00WH150* | ATZG | USB Memory Key for VMware ESXi 5.5 Update 3B | 1 / 2 |
00WH138 | ATRL | USB Memory Key 4G for VMware ESXi 6.0 Update 1A | 1 / 2 |
00WH151* | ATZH | USB Memory Key for VMware ESXi 6.0 Update 2 | 1 / 2 |
CTO only* | AVNW | USB Memory Key for VMware ESXi 6.5 | 1 / 2 |
* Not supported in servers with E7 v2 compute books
† 2 hypervisor keys are supported only if the x3950 X6 is configured to be partitioned, where the two halves of the server operate as two independent four-socket servers. However, CTO orders can include only one hypervisor key.
Systems management
The server contains Integrated Management Module 2.1 (IMM2), which provides advanced service-processor control, monitoring, and an alerting function. If an environmental condition exceeds a threshold or if a system component fails, the IMM2 lights LEDs to help you diagnose the problem, records the error in the event log, and alerts you to the problem. The IMM2 also provides a virtual presence capability for remote server management capabilities.
The IMM2 provides remote server management through industry-standard interfaces:
- Intelligent Platform Management Interface (IPMI) Version 2.0
- Simple Network Management Protocol (SNMP) Version 3
- Common Information Model (CIM)
- Web browser
The remote presence provides the following functions:
- Remotely viewing video with graphics resolutions up to 1600 x 1200 at 75 Hz with up to 23 bits per pixel colors, regardless of the system state
- Remotely accessing the server by using the keyboard and mouse from a remote client
- Mapping the CD or DVD drive, diskette drive, and USB flash drive on a remote client, and mapping ISO and diskette image files as virtual drives that are available for use by the server
- Uploading a diskette image to the IMM memory and mapping it to the server as a virtual drive
The blue-screen capture feature captures the video display contents before the IMM restarts the server when the IMM detects an operating-system hang condition. A system administrator can use the blue-screen capture feature to assist in determining the cause of the hang condition.
Lenovo XClarity Administrator
Lenovo XClarity Administrator is a centralized resource management solution designed to reduce complexity, speed response, and enhance the availability of Lenovo systems and solutions. It provides agent-free hardware management for ThinkSystem servers, in addition to ThinkServer, System x, and Flex System servers. The administration dashboard is based on HTML 5 and allows fast location of resources so tasks can be run quickly.
Because Lenovo XClarity Administrator does not require any agent software to be installed on the managed endpoints, there are no CPU cycles spent on agent execution, and no memory is used, which means that up to 1GB of RAM and 1 - 2% CPU usage is saved, compared to a typical managed system where an agent is required.
Lenovo XClarity Administrator is an optional software component for the x3950 X6. The software can be downloaded and used at no charge to discover and monitor the x3950 X6 and to manage firmware upgrades.
If software support is required for Lenovo XClarity Administrator, or premium features such as configuration management and operating system deployment are required, Lenovo XClarity Pro software subscription should be ordered. Lenovo XClarity Pro is licensed on a per managed system basis, that is, each managed Lenovo system requires a license.
The following table lists the Lenovo XClarity software license options.
Part number | Feature code | Description |
---|---|---|
00MT201 | 1339 | Lenovo XClarity Pro, per Managed Endpoint w/1 Yr SW S&S |
00MT202 | 1340 | Lenovo XClarity Pro, per Managed Endpoint w/3 Yr SW S&S |
00MT203 | 1341 | Lenovo XClarity Pro, per Managed Endpoint w/5 Yr SW S&S |
7S0X000HWW | SAYV | Lenovo XClarity Pro, per Managed Endpoint w/6 Yr SW S&S |
7S0X000JWW | SAYW | Lenovo XClarity Pro, per Managed Endpoint w/7 Yr SW S&S |
Lenovo XClarity Administrator offers the following standard features that are available at no charge:
- Auto-discovery and monitoring of Lenovo systems
- Firmware updates and compliance enforcement
- External alerts and notifications via SNMP traps, syslog remote logging, and e-mail
- Secure connections to managed endpoints
- NIST 800-131A or FIPS 140-2 compliant cryptographic standards between the management solution and managed endpoints
- Integration into existing higher-level management systems such as cloud automation and orchestration tools through REST APIs, providing extensive external visibility and control over hardware resources
- An intuitive, easy-to-use GUI
- Scripting with Windows PowerShell, providing command-line visibility and control over hardware resources
Lenovo XClarity Administrator offers the following premium features that require an optional Pro license:
- Pattern-based configuration management that allows to define configurations once and apply repeatedly without errors when deploying new servers or redeploying existing servers without disrupting the fabric
- Bare-metal deployment of operating systems and hypervisors to streamline infrastructure provisioning
For more information, refer to the Lenovo XClarity Administrator Product Guide:
http://lenovopress.com/tips1200
Lenovo XClarity Integrators
Lenovo also offers software plug-in modules, Lenovo XClarity Integrators, to manage physical infrastructure from leading external virtualization management software tools including those from Microsoft and VMware.
These integrators are offered at no charge, however if software support is required, a Lenovo XClarity Pro software subscription license should be ordered.
Lenovo XClarity Integrators offer the following additional features:
- Ability to discover, manage, and monitor Lenovo server hardware from VMware vCenter or Microsoft System Center
- Deployment of firmware updates and configuration patterns to Lenovo x86 rack servers and Flex System from the virtualization management tool
- Non-disruptive server maintenance in clustered environments that reduces workload downtime by dynamically migrating workloads from affected hosts during rolling server updates or reboots
- Greater service level uptime and assurance in clustered environments during unplanned hardware events by dynamically triggering workload migration from impacted hosts when impending hardware failures are predicted
For more information about all the available Lenovo XClarity Integrators, see the Lenovo XClarity Administrator Product Guide: https://lenovopress.com/tips1200-lenovo-xclarity-administrator
Rack installation
All models of the x3950 X6 include a rail kit and cable management bracket kit for installation in a 19-inch rack cabinet. The contents of the kits are shown in the following figure.
Figure 14. x3950 X6 rail kit and cable management bracket kit
Operating system support
Operating system support is based on the compute books installed in the server.
For a complete list of supported, certified and tested operating systems, plus additional details and links to relevant web sites, see the Operating System Interoperability Guide: https://lenovopress.com/osig
The following operating systems are supported with E7 v4 compute books:
- Microsoft Windows Server 2012
- Microsoft Windows Server 2012 R2
- Microsoft Windows Server 2016
- Microsoft Windows Server 2019
- Microsoft Windows Server, version 1709
- Red Hat Enterprise Linux 6.7 x64
- Red Hat Enterprise Linux 6.8 x64
- Red Hat Enterprise Linux 6.10 x64
- Red Hat Enterprise Linux 7.2
- Red Hat Enterprise Linux 7.3
- Red Hat Enterprise Linux 7.4
- Red Hat Enterprise Linux 7.5
- Red Hat Enterprise Linux 7.6
- Red Hat Enterprise Linux 7.7
- Red Hat Enterprise Linux 7.8
- Red Hat Enterprise Linux 7.9
- Red Hat Enterprise Linux 8.0
- Red Hat Enterprise Linux 8.1
- Red Hat Enterprise Linux 8.2
- Red Hat Enterprise Linux 8.3
- Red Hat Enterprise Linux 8.4
- Red Hat Enterprise Linux 8.5
- Red Hat Enterprise Linux 8.6
- Red Hat Enterprise Linux 8.7
- Red Hat Enterprise Linux 8.8
- SUSE Linux Enterprise Server 11 Xen x64 SP4
- SUSE Linux Enterprise Server 11 x64 SP4
- SUSE Linux Enterprise Server 12 SP1
- SUSE Linux Enterprise Server 12 SP2
- SUSE Linux Enterprise Server 12 SP3
- SUSE Linux Enterprise Server 12 SP4
- SUSE Linux Enterprise Server 12 SP5
- SUSE Linux Enterprise Server 12 Xen SP1
- SUSE Linux Enterprise Server 12 Xen SP2
- SUSE Linux Enterprise Server 12 Xen SP3
- SUSE Linux Enterprise Server 12 Xen SP4
- SUSE Linux Enterprise Server 12 Xen SP5
- SUSE Linux Enterprise Server 15
- SUSE Linux Enterprise Server 15 SP1
- SUSE Linux Enterprise Server 15 SP2
- SUSE Linux Enterprise Server 15 SP3
- SUSE Linux Enterprise Server 15 SP4
- SUSE Linux Enterprise Server 15 SP5
- SUSE Linux Enterprise Server 15 Xen
- SUSE Linux Enterprise Server 15 Xen SP1
- SUSE Linux Enterprise Server 15 Xen SP2
- SUSE Linux Enterprise Server 15 Xen SP3
- SUSE Linux Enterprise Server 15 Xen SP4
- SUSE Linux Enterprise Server 15 Xen SP5
- VMware ESXi 6.0 U2
- VMware ESXi 6.0 U3
- VMware ESXi 6.5
- VMware ESXi 6.5 U1
- VMware ESXi 6.5 U2
- VMware ESXi 6.5 U3
- VMware ESXi 6.7
- VMware ESXi 6.7 U1
- VMware ESXi 6.7 U2
- VMware ESXi 6.7 U3
The following operating systems are supported with E7 v3 compute books:
- Microsoft Windows Server 2008 R2 SP1
- Microsoft Windows Server 2012
- Microsoft Windows Server 2012 R2
- Microsoft Windows Server 2016
- Microsoft Windows Server, version 1709
- Red Hat Enterprise Linux 6.6 x64
- Red Hat Enterprise Linux 6.7 x64
- Red Hat Enterprise Linux 6.8 x64
- Red Hat Enterprise Linux 6.10 x64
- Red Hat Enterprise Linux 7.1
- Red Hat Enterprise Linux 7.2
- Red Hat Enterprise Linux 7.3
- Red Hat Enterprise Linux 7.4
- Red Hat Enterprise Linux 7.5
- Red Hat Enterprise Linux 7.6
- Red Hat Enterprise Linux 7.7
- Red Hat Enterprise Linux 7.8
- Red Hat Enterprise Linux 7.9
- SUSE Linux Enterprise Server 11 Xen x64 SP3
- SUSE Linux Enterprise Server 11 Xen x64 SP4
- SUSE Linux Enterprise Server 11 x64 SP3
- SUSE Linux Enterprise Server 11 x64 SP4
- SUSE Linux Enterprise Server 12
- SUSE Linux Enterprise Server 12 SP1
- SUSE Linux Enterprise Server 12 SP2
- SUSE Linux Enterprise Server 12 SP3
- SUSE Linux Enterprise Server 12 SP4
- SUSE Linux Enterprise Server 12 SP5
- SUSE Linux Enterprise Server 12 Xen
- SUSE Linux Enterprise Server 12 Xen SP1
- SUSE Linux Enterprise Server 12 Xen SP2
- SUSE Linux Enterprise Server 12 Xen SP3
- SUSE Linux Enterprise Server 12 Xen SP4
- SUSE Linux Enterprise Server 12 Xen SP5
- SUSE Linux Enterprise Server 15
- SUSE Linux Enterprise Server 15 SP1
- SUSE Linux Enterprise Server 15 SP2
- SUSE Linux Enterprise Server 15 SP3
- SUSE Linux Enterprise Server 15 SP4
- SUSE Linux Enterprise Server 15 SP5
- SUSE Linux Enterprise Server 15 Xen
- SUSE Linux Enterprise Server 15 Xen SP1
- SUSE Linux Enterprise Server 15 Xen SP2
- SUSE Linux Enterprise Server 15 Xen SP3
- SUSE Linux Enterprise Server 15 Xen SP4
- SUSE Linux Enterprise Server 15 Xen SP5
- VMware ESXi 5.5 U2
- VMware ESXi 5.5 U3
- VMware ESXi 6.0
- VMware ESXi 6.0 U1
- VMware ESXi 6.0 U2
- VMware ESXi 6.0 U3
- VMware ESXi 6.5
- VMware ESXi 6.5 U1
- VMware ESXi 6.5 U2
- VMware ESXi 6.5 U3
The following operating systems are supported with E7 v2 compute books:
- Microsoft Windows Server 2008 R2 SP1
- Microsoft Windows Server 2012
- Microsoft Windows Server 2012 R2
- Red Hat Enterprise Linux 6.5 x64
- Red Hat Enterprise Linux 6.6 x64
- Red Hat Enterprise Linux 6.7 x64
- Red Hat Enterprise Linux 6.8 x64
- Red Hat Enterprise Linux 6.10 x64
- Red Hat Enterprise Linux 7.0
- Red Hat Enterprise Linux 7.1
- Red Hat Enterprise Linux 7.2
- Red Hat Enterprise Linux 7.6
- Red Hat Enterprise Linux 7.7
- Red Hat Enterprise Linux 7.8
- Red Hat Enterprise Linux 7.9
- SUSE Linux Enterprise Server 11 Xen x64 SP3
- SUSE Linux Enterprise Server 11 Xen x64 SP4
- SUSE Linux Enterprise Server 11 x64 SP3
- SUSE Linux Enterprise Server 11 x64 SP4
- SUSE Linux Enterprise Server 12
- SUSE Linux Enterprise Server 12 SP1
- SUSE Linux Enterprise Server 12 SP2
- SUSE Linux Enterprise Server 12 SP3
- SUSE Linux Enterprise Server 12 SP4
- SUSE Linux Enterprise Server 12 Xen
- SUSE Linux Enterprise Server 12 Xen SP1
- SUSE Linux Enterprise Server 12 Xen SP2
- SUSE Linux Enterprise Server 12 Xen SP3
- SUSE Linux Enterprise Server 12 Xen SP4
- VMware ESXi 5.1 U2
- VMware ESXi 5.1 U3
- VMware ESXi 5.5
- VMware ESXi 5.5 U1
- VMware ESXi 5.5 U2
- VMware ESXi 5.5 U3
- VMware ESXi 6.0
- VMware ESXi 6.0 U1
- VMware ESXi 6.0 U2
Physical and environmental specifications
Dimensions and weight:
- Height: 351 mm (13.7 in.)
- Width: 482 mm (19.0 in.)
- Depth: 804 mm (31.6 in)
- Depth with cable management brackets installed: 836 mm (32.9”)
- Depth with Full-length I/O Book installed: 921 mm (36.2 in)
- Weight:
- Minimum configuration: 84.5 kg (186.3 lb)
- Typical configuration: 88.2 kg (194.5 lb)
- Maximum configuration: 110.0 kg (242.6 lb)
Supported environment:
- The server is designed to the ASHRAE Class A3 guidelines
- Air temperature:
- Server on: 5 °C to 40 °C (41 °F to 104 °F); altitude: 0 - 3,050 m (10,000 ft).
- Server off: 5 °C to 45 °C (41 °F to 113 °F); altitude: 0 - 3,050 m (10,000 ft).
- Shipment: -40 °C to 60 °C (-40 °F to 140 °F)
- Humidity:
- Server on: 8% - 85%, maximum dew point 24 °C
- Server off: 8% - 85%, maximum dew point 27 °C
- Electrical:
- Models with 1400 W AC power supplies:
- 100 - 127 (nominal) V AC; 50 Hz or 60 Hz; 10 A (900 W DC output)
- 200 - 240 (nominal) V AC; 50 Hz or 60 Hz; 8 A (1400 W DC output)
- Input kilovolt-amperes (kVA) (approximately):
- Minimum configuration: 0.16 kVA
- Maximum configuration: 3.2 kVA
- Models with 900 W AC power supplies:
- 100 - 127 (nominal) V ac; 50 Hz or 60 Hz; 10.7 A
- 200 - 240 (nominal) V ac; 50 Hz or 60 Hz; 5.3 A
- Input kilovolt-amperes (kVA) (approximately):
- Minimum configuration: 0.16 kVA
- Maximum configuration: 2.0 kVA
- Models with 750 W DC power supplies:
- -40 to -75 (nominal) V DC
- Input kilovolt-amperes (kVA) (approximately):
- Minimum configuration: 0.16 kVA
- Maximum configuration: 1.7 kVA
- Models with 1400 W AC power supplies:
- BTU output:
- Minimum configuration: 546 Btu/hr (160 watts)
- Maximum configuration: 10,912 Btu/hr (3,200 watts)
- Noise level:
- 6.6 bels (operating)
- 6.4 bels (idle)
Warranty and Support
The System x3950 X6, machine type 6241 has a three-year warranty.
Our global network of regional support centers offers consistent, local-language support enabling you to vary response times and level of service to match the criticality of your support needs:
- Standard Next Business Day – Best choice for non-essential systems requiring simple maintenance.
- Premier Next Business Day – Best choice for essential systems requiring technical expertise from senior-level Lenovo engineers.
- Premier 24x7 4-Hour Response – Best choice for systems where maximum uptime is critical.
- Premier Enhanced Storage Support 24x7 4-Hour Response – Best choice for storage systems where maximum uptime is critical.
For more information, consult the brochure Lenovo Operational Support Services for Data Centers Services.
Services
Lenovo Data Center Services empower you at every stage of your IT lifecycle. From expert advisory and strategic planning to seamless deployment and ongoing support, we ensure your infrastructure is built for success. Our comprehensive services accelerate time to value, minimize downtime, and free your IT staff to focus on driving innovation and business growth.
Note: Some service options may not be available in all markets or regions. For more information, go to https://lenovolocator.com/. For information about Lenovo service upgrade offerings that are available in your region, contact your local Lenovo sales representative or business partner.
In this section:
- Lenovo Advisory Services
- Lenovo Plan & Design Services
- Lenovo Deployment, Migration, and Configuration Services
- Lenovo Support Services
- Lenovo Managed Services
- Lenovo Sustainability Services
Lenovo Advisory Services
Lenovo Advisory Services simplify the planning process, enabling customers to build future-proofed strategies in as little as six weeks. Consultants provide guidance on projects including VM migration, storage, backup and recovery, and cost management to accelerate time to value, improve cost efficiency, and build a flexibly scalable foundation.
- Assessment Services
An Assessment helps solve your IT challenges through an onsite, multi-day session with a Lenovo technology expert. We perform a tools-based assessment which provides a comprehensive and thorough review of a company's environment and technology systems. In addition to the technology based functional requirements, the consultant also discusses and records the non-functional business requirements, challenges, and constraints. Assessments help organizations like yours, no matter how large or small, get a better return on your IT investment and overcome challenges in the ever-changing technology landscape.
- Design Services
Professional Services consultants perform infrastructure design and implementation planning to support your strategy. The high-level architectures provided by the assessment service are turned into low level designs and wiring diagrams, which are reviewed and approved prior to implementation. The implementation plan will demonstrate an outcome-based proposal to provide business capabilities through infrastructure with a risk-mitigated project plan.
Lenovo Plan & Design Services
Unlock faster time to market with our tailored, strategic design workshops to align solution approaches with your business goals and technical requirements. Leverage our deep solution expertise and end-to-end delivery partnership to meet your goals efficiently and effectively.
Lenovo Deployment, Migration, and Configuration Services
Optimize your IT operations by shifting labor-intensive functions to Lenovo's skilled technicians for seamless on-site or remote deployment, configuration, and migration. Enjoy peace of mind, faster time to value, and comprehensive knowledge sharing with your IT staff, backed by our best-practice methodology.
- Deployment Services for Storage and ThinkAgile
A comprehensive range of remote and onsite options tailored specifically for your business needs to ensure your storage and ThinkAgile hardware are fully operational from the start.
- Hardware Installation Services
A full-range, comprehensive setup for your hardware, including unpacking, inspecting, and positioning components to ensure your equipment is operational and error-free for the most seamless and efficient installation experience, so you can quickly benefit from your investments.
- DM/DG File Migration Services
Take the burden of file migration from your IT’s shoulders. Our experts will align your requirements and business objectives to the migration plans while coordinating with your team to plan and safely execute the data migration to your storage platforms.
- DM/DG/DE Health Check Services
Our experts perform proactive checks of your Firmware and system health to ensure your machines are operating at peak and optimal efficiency to maximize up-time, avoid system failures, ensure the security of IT solutions and simplify maintenance.
- Factory Integrated Services
A suite of value-added offerings provided during the manufacturing phase of a server or storage system that reduces time to value. These services aim at improving your hardware deployment experience and enhance the quality of a standard configuration before it arrives at your facility.
Lenovo Support Services
In addition to response time options for hardware parts, repairs, and labor, Lenovo offers a wide array of additional support services to ensure your business is positioned for success and longevity. Our goal is to reduce your capital outlays, mitigate your IT risks, and accelerate your time to productivity.
- Premier Support for Data Centers
Your direct line to the solution that promises the best, most comprehensive level of support to help you fully unlock the potential of your data center.
- Premier Enhanced Storage Support (PESS)
Gain all the benefits of Premier Support for Data Centers, adding dedicated storage specialists and resources to elevate your storage support experience to the next level.
- Committed Service Repair (CSR)
Our commitment to ensuring the fastest, most seamless resolution times for mission-critical systems that require immediate attention to ensure minimal downtime and risk for your business. This service is only available for machines under the Premier 4-Hour Response SLA.
- Multivendor Support Services (MVS)
Your single point of accountability for resolution support across vast range of leading Server, Storage, and Networking OEMs, allowing you to manage all your supported infrastructure devices seamlessly from a single source.
- Keep Your Drive (KYD)
Protect sensitive data and maintain compliance with corporate retention and disposal policies to ensure your data is always under your control, regardless of the number of drives that are installed in your Lenovo server.
- Technical Account Manager (TAM)
Your single point of contact to expedite service requests, provide status updates, and furnish reports to track incidents over time, ensuring smooth operations and optimized performance as your business grows.
- Enterprise Software Support (ESS)
Gain comprehensive, single-source, and global support for a wide range of server operating systems and Microsoft server applications.
For more information, consult the brochure Lenovo Operational Support Services for Data Centers.
Lenovo Managed Services
Achieve peak efficiency, high security, and minimal disruption with Lenovo's always-on Managed Services. Our real-time monitoring, 24x7 incident response, and problem resolution ensure your infrastructure operates seamlessly. With quarterly health checks for ongoing optimization and innovation, Lenovo's remote active monitoring boosts end-user experience and productivity by keeping your data center's hardware performing at its best.
Lenovo Managed Services provides continuous 24x7 remote monitoring (plus 24x7 call center availability) and proactive management of your data center using state-of-the-art tools, systems, and practices by a team of highly skilled and experienced Lenovo services professionals.
Quarterly reviews check error logs, verify firmware & OS device driver levels, and software as needed. We’ll also maintain records of latest patches, critical updates, and firmware levels, to ensure you systems are providing business value through optimized performance.
Lenovo Sustainability Services
- Asset Recovery Services
Lenovo Asset Recovery Services (ARS) provides a secure, seamless solution for managing end-of-life IT assets, ensuring data is safely sanitized while contributing to a more circular IT lifecycle. By maximizing the reuse or responsible recycling of devices, ARS helps businesses meet sustainability goals while recovering potential value from their retired equipment. For more information, see the Asset Recovery Services offering page.
- CO2 Offset Services
Lenovo’s CO2 Offset Services offer a simple and transparent way for businesses to take tangible action on their IT footprint. By integrating CO2 offsets directly into device purchases, customers can easily support verified climate projects and track their contributions, making meaningful progress toward their sustainability goals without added complexity.
- Lenovo Certified Refurbished
Lenovo Certified Refurbished offers a cost-effective way to support IT circularity without compromising on quality and performance. Each device undergoes rigorous testing and certification, ensuring reliable performance and extending its lifecycle. With Lenovo’s trusted certification, you gain peace of mind while making a more sustainable IT choice.
Regulatory compliance
The server conforms to the following regulations:
- Energy Star 2.0
- FCC - Verified to comply with Part 15 of the FCC Rules, Class A
- Canada ICES-003, issue 4, Class A
- UL/IEC 60950-1
- CSA C22.2 No. 60950-1
- NOM-019
- Argentina IEC60950-1
- Japan VCCI, Class A
- Australia/New Zealand AS/NZS CISPR 22, Class A
- IEC 60950-1(CB Certificate and CB Test Report)
- China CCC (GB4943), GB9254 Class A, GB17625.1
- Taiwan BSMI CNS13438, Class A; CNS14336-1
- Korea KN22, Class A; KN24
- Russia/GOST ME01, IEC-60950-1, GOST R 51318.22, GOST R 51318.24, GOST R 51317.3.2, and GOST R 51317.3.3
- IEC 60950-1 (CB Certificate and CB Test Report)
- CE Mark (EN55022 Class A, EN60950-1, EN55024, EN61000-3-2, and EN61000-3-3)
- CISPR 22, Class A
- TUV-GS (EN60950-1 /IEC60950-1, EK1-ITB2000)
External drive enclosures
The server supports attachment to external drive enclosures using a RAID controller with external ports or a SAS host bus adapter. Adapters supported by the server are listed in the SAS adapters for external storage section.
The following table lists the 6 Gbps SAS external drive enclosures that are offered by Lenovo that can be used with the server for storage expansion.
Part number | Description |
---|---|
64111B1 | Lenovo Storage E1012 LFF Disk Expansion Single SAS IO Module, Rail Kit, 9x5 NBD |
64111B2 | Lenovo Storage E1012 LFF Disk Expansion Dual SAS IO Module, Rail Kit, 9x5 NBD |
64111B3 | Lenovo Storage E1024 SFF Disk Expansion Single SAS IO Module, Rail Kit, 9x5 NBD |
64111B4 | Lenovo Storage E1024 SFF Disk Expansion Dual SAS IO Module, Rail Kit, 9x5 NBD |
For details about supported drives and cables for the Lenovo Storage E1012 and E1024, see the Lenovo Press Product Guide:
http://lenovopress.com/lp0043
The following table lists the 12 Gbps SAS external drive enclosures offered by Lenovo that can be used with the server for storage expansion.
Note: Information provided in this section is for ordering reference purposes only. For the operating system and adapter support details, refer to the interoperability matrix for a particular storage enclosure that can be found on the Lenovo Data Center Support web site:
http://datacentersupport.lenovo.com
Description | Part number | ||
---|---|---|---|
Worldwide | Japan | PRC | |
Lenovo Storage D1212 LFF Disk Expansion with Dual SAS IO Modules | 4587A11 | 4587A1J | 4587A1C |
Lenovo Storage D1224 SFF Disk Expansion with Dual SAS IO Modules | 4587A31 | 4587A3J | 4587A3C |
Lenovo Storage D3284 4TB x 84 HD Expansion Enclosure | 641311F | ||
Lenovo Storage D3284 6TB x 84 HD Expansion Enclosure | 641312F | ||
Lenovo Storage D3284 8TB x 84 HD Expansion Enclosure | 641313F | ||
Lenovo Storage D3284 10TB x 84 HD Expansion Enclosure | 641314F |
For details about supported drives, adapters, and cables, see the following Lenovo Press Product Guides:
- Lenovo Storage D1212 and D1224
http://lenovopress.com/lp0512 - Lenovo Storage D3284
http://lenovopress.com/lp0513
External storage systems
Lenovo offers the ThinkSystem DE Series and ThinkSystem DM Series external storage systems for high-performance storage. See the DE Series and DM Series product guides for specific controller models, expansion enclosures and configuration options:
- ThinkSystem DE Series Storage
https://lenovopress.com/storage/thinksystem/de-series#rt=product-guide - ThinkSystem DM Series Storage
https://lenovopress.com/storage/thinksystem/dm-series#rt=product-guide - ThinkSystem DG Series Storage
https://lenovopress.com/storage/thinksystem/dg-series#rt=product-guide
External backup units
The following table lists the external backup options that are offered by Lenovo.
Part number | Description |
---|---|
External RDX USB drives | |
4T27A10725 | ThinkSystem RDX External USB 3.0 Dock |
External SAS tape backup drives | |
6160S7E | IBM TS2270 Tape Drive Model H7S |
6160S8E | IBM TS2280 Tape Drive Model H8S |
6160S9E | IBM TS2290 Tape Drive Model H9S |
External SAS tape backup autoloaders | |
6171S7R | IBM TS2900 Tape Autoloader w/LTO7 HH SAS |
6171S8R | IBM TS2900 Tape Autoloader w/LTO8 HH SAS |
6171S9R | IBM TS2900 Tape Autoloader w/LTO9 HH SAS |
External tape backup libraries | |
6741A1F | IBM TS4300 3U Tape Library-Base Unit |
6741A3F | IBM TS4300 3U Tape Library-Expansion Unit |
Full High 8 Gb Fibre Channel for TS4300 | |
01KP938 | LTO 7 FH Fibre Channel Drive |
01KP954 | LTO 8 FH Fibre Channel Drive |
02JH837 | LTO 9 FH Fibre Channel Drive |
Half High 8 Gb Fibre Channel for TS4300 | |
01KP936 | LTO 7 HH Fibre Channel Drive |
01KP952 | LTO 8 HH Fibre Channel Drive |
02JH835 | LTO 9 HH Fibre Channel Drive |
Half High 6 Gb SAS for TS4300 | |
01KP937 | LTO 7 HH SAS Drive |
01KP953 | LTO 8 HH SAS Drive |
02JH836 | LTO 9 HH SAS Drive |
For more information, see the list of Product Guides in the Backup units category:
https://lenovopress.com/servers/options/backup
Top-of-rack Ethernet switches
The following table lists the Ethernet LAN switches that are offered by Lenovo.
Part number | Description |
---|---|
1 Gb Ethernet Rack switches | |
7Y810011WW | Lenovo ThinkSystem NE0152T RackSwitch (Rear to Front) |
7Z320O11WW | Lenovo ThinkSystem NE0152TO RackSwitch (Rear to Front, ONIE) |
7159BAX | Lenovo RackSwitch G7028 (Rear to Front) |
7159CAX | Lenovo RackSwitch G7052 (Rear to Front) |
7159G52 | Lenovo RackSwitch G8052 (Rear to Front) |
7165H1X | Juniper EX2300-C PoE Switch |
7165H2X | Juniper EX2300-24p PoE Switch |
1 Gb Ethernet Campus switches | |
7Z340011WW | Lenovo CE0128TB Switch (3-Year Warranty) |
7Z360011WW | Lenovo CE0128TB Switch (Limited Lifetime Warranty) |
7Z340012WW | Lenovo CE0128PB Switch (3-Year Warranty) |
7Z360012WW | Lenovo CE0128PB Switch (Limited Lifetime Warranty) |
7Z350021WW | Lenovo CE0152TB Switch (3-Year Warranty) |
7Z370021WW | Lenovo CE0152TB Switch (Limited Lifetime Warranty) |
7Z350022WW | Lenovo CE0152PB Switch (3-Year Warranty) |
7Z370022WW | Lenovo CE0152PB Switch (Limited Lifetime Warranty) |
10 Gb Ethernet switches | |
7159A1X | Lenovo ThinkSystem NE1032 RackSwitch (Rear to Front) |
7159B1X | Lenovo ThinkSystem NE1032T RackSwitch (Rear to Front) |
7Z330O11WW | Lenovo ThinkSystem NE1064TO RackSwitch (Rear to Front, ONIE) |
7159C1X | Lenovo ThinkSystem NE1072T RackSwitch (Rear to Front) |
7159CRW | Lenovo RackSwitch G8272 (Rear to Front) |
7159GR6 | Lenovo RackSwitch G8296 (Rear to Front) |
7159BR6 | Lenovo RackSwitch G8124E (Rear to Front) |
25 Gb Ethernet switches | |
7159E1X | Lenovo ThinkSystem NE2572 RackSwitch (Rear to Front) |
7Z210O21WW | Lenovo ThinkSystem NE2572O RackSwitch (Rear to Front, ONIE) |
7Z330O21WW | Lenovo ThinkSystem NE2580O RackSwitch (Rear to Front, ONIE) |
100 Gb Ethernet switches | |
7159D1X | Lenovo ThinkSystem NE10032 RackSwitch (Rear to Front) |
7Z210O11WW | Lenovo ThinkSystem NE10032O RackSwitch (Rear to Front, ONIE) |
For more information, see the list of Product Guides in the following switch categories:
- 1 Gb Ethernet switches: http://lenovopress.com/networking/tor/1gb?rt=product-guide
- 10 Gb Ethernet switches: http://lenovopress.com/networking/tor/10gb?rt=product-guide
- 25 Gb Ethernet switches: http://lenovopress.com/networking/tor/25gb?rt=product-guide
- 40 Gb Ethernet switches: http://lenovopress.com/networking/tor/40gb?rt=product-guide
- 100 Gb Ethernet switches: https://lenovopress.com/networking/tor/100Gb?rt=product-guide
Fibre Channel SAN switches
Lenovo offers the ThinkSystem DB Series of Fibre Channel SAN switches for high-performance storage expansion. See the DB Series product guides for models and configuration options:
- ThinkSystem DB Series SAN Switches:
https://lenovopress.com/storage/switches/rack#rt=product-guide
Uninterruptible power supply units
The following table lists the uninterruptible power supply (UPS) units that are offered by Lenovo.
Part number | Description |
---|---|
Rack-mounted or tower UPS units - 100-125VAC | |
7DD5A001WW | RT1.5kVA 2U Rack or Tower UPS-G2 (100-125VAC) |
55941AX | RT1.5kVA 2U Rack or Tower UPS (100-125VAC) |
55942AX | RT2.2kVA 2U Rack or Tower UPS (100-125VAC) |
7DD5A003WW | RT3kVA 2U Rack or Tower UPS-G2 (100-125VAC) |
55943AX | RT3kVA 2U Rack or Tower UPS (100-125VAC) |
Rack-mounted or tower UPS units - 200-240VAC | |
7DD5A002WW | RT1.5kVA 2U Rack or Tower UPS-G2 (200-240VAC) |
55941KX | RT1.5kVA 2U Rack or Tower UPS (200-240VAC) |
55942KX | RT2.2kVA 2U Rack or Tower UPS (200-240VAC) |
7DD5A005WW | RT3kVA 2U Rack or Tower UPS-G2 (200-240VAC) |
55943KX | RT3kVA 2U Rack or Tower UPS (200-240VAC) |
7DD5A007WW | RT5kVA 3U Rack or Tower UPS-G2 (200-240VAC) |
55945KX | RT5kVA 3U Rack or Tower UPS (200-240VAC) |
7DD5A008WW | RT6kVA 3U Rack or Tower UPS-G2 (200-240VAC) |
55946KX | RT6kVA 3U Rack or Tower UPS (200-240VAC) |
55948KX | RT8kVA 6U Rack or Tower UPS (200-240VAC) |
7DD5A00AWW | RT11kVA 6U Rack or Tower UPS-G2 (200-240VAC) |
55949KX | RT11kVA 6U Rack or Tower UPS (200-240VAC) |
55943KT† | ThinkSystem RT3kVA 2U Standard UPS (200-230VAC) (2x C13 10A, 2x GB 10A, 1x C19 16A outlets) |
55943LT† | ThinkSystem RT3kVA 2U Long Backup UPS (200-230VAC) (2x C13 10A, 2x GB 10A, 1x C19 16A outlets) |
55946KT† | ThinkSystem RT6kVA 5U UPS (200-230VAC) (2x C13 10A outlets, 1x Terminal Block output) |
5594XKT† | ThinkSystem RT10kVA 5U UPS (200-230VAC) (2x C13 10A outlets, 1x Terminal Block output) |
Rack-mounted or tower UPS units - 380-415VAC | |
55948PX | RT8kVA 6U 3:1 Phase Rack or Tower UPS (380-415VAC) |
55949PX | RT11kVA 6U 3:1 Phase Rack or Tower UPS (380-415VAC) |
† Only available in China and the Asia Pacific market.
For more information, see the list of Product Guides in the UPS category:
https://lenovopress.com/servers/options/ups
Power distribution units
The following table lists the power distribution units (PDUs) that are offered by Lenovo.
Part number |
Feature code |
Description |
ANZ
|
ASEAN
|
Brazil
|
EET
|
MEA
|
RUCIS
|
WE
|
HTK
|
INDIA
|
JAPAN
|
LA
|
NA
|
PRC
|
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
0U Basic PDUs | |||||||||||||||
4PU7A93176 | C0QH | 0U 36 C13 and 6 C19 Basic 32A 1 Phase PDU v2 | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
4PU7A93169 | C0DA | 0U 36 C13 and 6 C19 Basic 32A 1 Phase PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
4PU7A93177 | C0QJ | 0U 24 C13/C15 and 24 C13/C15/C19 Basic 32A 3 Phase WYE PDU v2 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
4PU7A93170 | C0D9 | 0U 24 C13/C15 and 24 C13/C15/C19 Basic 32A 3 Phase WYE PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
00YJ776 | ATZY | 0U 36 C13/6 C19 24A 1 Phase PDU | N | Y | Y | N | N | N | N | N | N | Y | Y | Y | N |
00YJ779 | ATZX | 0U 21 C13/12 C19 48A 3 Phase PDU | N | N | Y | N | N | N | Y | N | N | Y | Y | Y | N |
00YJ777 | ATZZ | 0U 36 C13/6 C19 32A 1 Phase PDU | Y | Y | N | Y | Y | Y | Y | Y | Y | N | N | Y | Y |
00YJ778 | AU00 | 0U 21 C13/12 C19 32A 3 Phase PDU | Y | Y | N | Y | Y | Y | Y | Y | Y | N | N | Y | Y |
0U Switched and Monitored PDUs | |||||||||||||||
4PU7A93181 | C0QN | 0U 21 C13/C15 and 21 C13/C15/C19 Switched and Monitored 48A 3 Phase Delta PDU V2 (60A derated) | N | Y | N | N | N | N | N | Y | N | Y | N | Y | N |
4PU7A93174 | C0D5 | 0U 21 C13/C15 and 21 C13/C15/C19 Switched and Monitored 48A 3 Phase Delta PDU (60A derated) | N | Y | N | Y | N | N | Y | Y | N | N | N | Y | N |
4PU7A93178 | C0QK | 0U 20 C13 and 4 C19 Switched and Monitored 32A 1 Phase PDU v2 | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
4PU7A93171 | C0D8 | 0U 20 C13 and 4 C19 Switched and Monitored 32A 1 Phase PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
4PU7A93182 | C0QP | 0U 18 C13/C15 and 18 C13/C15/C19 Switched and Monitored 63A 3 Phase WYE PDU v2 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
4PU7A93175 | C0CS | 0U 18 C13/C15 and 18 C13/C15/C19 Switched and Monitored 63A 3 Phase WYE PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
4PU7A93180 | C0QM | 0U 18 C13/C15 and 18 C13/C15/C19 Switched and Monitored 32A 3 Phase WYE PDU v2 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
4PU7A93173 | C0D6 | 0U 18 C13/C15 and 18 C13/C15/C19 Switched and Monitored 32A 3 Phase WYE PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
4PU7A93179 | C0QL | 0U 16 C13/C15 and 16 C13/C15/C19 Switched and Monitored 24A 1 Phase PDU v2 (30A derated) | N | Y | N | N | N | N | N | Y | N | Y | N | Y | N |
4PU7A93172 | C0D7 | 0U 16 C13/C15 and 16 C13/C15/C19 Switched and Monitored 24A 1 Phase PDU(30A derated) | N | Y | N | Y | N | N | Y | Y | N | N | N | Y | N |
00YJ783 | AU04 | 0U 12 C13/12 C19 Switched and Monitored 48A 3 Phase PDU | N | N | Y | N | N | N | Y | N | N | Y | Y | Y | N |
00YJ781 | AU03 | 0U 20 C13/4 C19 Switched and Monitored 24A 1 Phase PDU | N | N | Y | N | Y | N | Y | N | N | Y | Y | Y | N |
00YJ782 | AU02 | 0U 18 C13/6 C19 Switched and Monitored 32A 3 Phase PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | N | Y |
00YJ780 | AU01 | 0U 20 C13/4 C19 Switched and Monitored 32A 1 Phase PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | N | Y |
1U Switched and Monitored PDUs | |||||||||||||||
4PU7A90808 | C0D4 | 1U 18 C19/C13 Switched and monitored 48A 3P WYE PDU V2 ETL | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
4PU7A81117 | BNDV | 1U 18 C19/C13 switched and monitored 48A 3P WYE PDU - ETL | N | N | N | N | N | N | N | N | N | N | N | Y | N |
4PU7A90809 | C0DE | 1U 18 C19/C13 Switched and monitored 48A 3P WYE PDU V2 CE | N | N | N | N | N | Y | Y | N | N | N | N | N | N |
4PU7A81118 | BNDW | 1U 18 C19/C13 switched and monitored 48A 3P WYE PDU - CE | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | N | Y |
4PU7A90810 | C0DD | 1U 18 C19/C13 Switched and monitored 80A 3P Delta PDU V2 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
4PU7A77467 | BLC4 | 1U 18 C19/C13 Switched and Monitored 80A 3P Delta PDU | N | N | N | N | N | N | N | N | N | Y | N | Y | N |
4PU7A90811 | C0DC | 1U 12 C19/C13 Switched and monitored 32A 3P WYE PDU V2 | N | N | N | N | N | Y | Y | N | N | N | N | N | N |
4PU7A77468 | BLC5 | 1U 12 C19/C13 switched and monitored 32A 3P WYE PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
4PU7A90812 | C0DB | 1U 12 C19/C13 Switched and monitored 60A 3P Delta PDU V2 | N | N | N | N | N | N | N | N | N | Y | N | N | N |
4PU7A77469 | BLC6 | 1U 12 C19/C13 switched and monitored 60A 3P Delta PDU | N | N | N | N | N | N | N | N | N | N | N | Y | N |
46M4002 | 5896 | 1U 9 C19/3 C13 Switched and Monitored DPI PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
46M4004 | 5894 | 1U 12 C13 Switched and Monitored DPI PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
46M4003 | 5897 | 1U 9 C19/3 C13 Switched and Monitored 60A 3 Phase PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
46M4005 | 5895 | 1U 12 C13 Switched and Monitored 60A 3 Phase PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
1U Ultra Density Enterprise PDUs (9x IEC 320 C13 + 3x IEC 320 C19 outlets) | |||||||||||||||
71763NU | 6051 | Ultra Density Enterprise C19/C13 PDU 60A/208V/3PH | N | N | Y | N | N | N | N | N | N | Y | Y | Y | N |
71762NX | 6091 | Ultra Density Enterprise C19/C13 PDU Module | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
1U C13 Enterprise PDUs (12x IEC 320 C13 outlets) | |||||||||||||||
39M2816 | 6030 | DPI C13 Enterprise PDU Plus Module (WW) | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
39Y8941 | 6010 | DPI C13 Enterprise PDU Module (WW) | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
1U C19 Enterprise PDUs (6x IEC 320 C19 outlets) | |||||||||||||||
39Y8948 | 6060 | DPI C19 Enterprise PDU Module (WW) | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
39Y8923 | 6061 | DPI Three-phase 60A/208V C19 Enterprise PDU (US) | N | N | Y | N | N | N | Y | N | N | N | Y | Y | N |
1U Front-end PDUs (3x IEC 320 C19 outlets) | |||||||||||||||
39Y8938 | 6002 | DPI Single-phase 30A/120V Front-end PDU (US) | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
39Y8939 | 6003 | DPI Single-phase 30A/208V Front-end PDU (US) | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
39Y8934 | 6005 | DPI Single-phase 32A/230V Front-end PDU (International) | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
39Y8940 | 6004 | DPI Single-phase 60A/208V Front-end PDU (US) | Y | N | Y | Y | Y | Y | Y | N | N | Y | Y | Y | N |
39Y8935 | 6006 | DPI Single-phase 63A/230V Front-end PDU (International) | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
1U NEMA PDUs (6x NEMA 5-15R outlets) | |||||||||||||||
39Y8905 | 5900 | DPI 100-127V NEMA PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Line cords for 1U PDUs that ship without a line cord | |||||||||||||||
40K9611 | 6504 | 4.3m, 32A/380-415V, EPDU/IEC 309 3P+N+G 3ph wye (non-US) Line Cord | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
40K9612 | 6502 | 4.3m, 32A/230V, EPDU to IEC 309 P+N+G (non-US) Line Cord | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
40K9613 | 6503 | 4.3m, 63A/230V, EPDU to IEC 309 P+N+G (non-US) Line Cord | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
40K9614 | 6500 | 4.3m, 30A/208V, EPDU to NEMA L6-30P (US) Line Cord | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
40K9615 | 6501 | 4.3m, 60A/208V, EPDU to IEC 309 2P+G (US) Line Cord | N | N | Y | N | N | N | Y | N | N | Y | Y | Y | N |
40K9617 | 6505 | 4.3m, 32A/230V, Souriau UTG Female to AS/NZ 3112 (Aus/NZ) Line Cord | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
40K9618 | 6506 | 4.3m, 32A/250V, Souriau UTG Female to KSC 8305 (S. Korea) Line Cord | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
For more information, see the Lenovo Press documents in the PDU category:
https://lenovopress.com/servers/options/pdu
Rack cabinets
The server supports the rack cabinets that are listed in the following table.
Table 33. Rack cabinets
Part number | Description | Supported by x3950 X6 |
Maximum supported x3950 X6 |
2018-86X | 11U Office Enablement Kit | No | Not applicable |
9307-2PX | 25U Static S2 Standard Rack | No | Not applicable |
9307-2RX | 25U Standard Rack | No | Not applicable |
9307-4RX | 42U Standard Rack | No | Not applicable |
9307-4XX | 42U Standard Rack Extension | No | Not applicable |
9308-4EX | 42U Enterprise Expansion Rack | Yes* | 5 |
9308-4PX | 42U Enterprise Rack | Yes* | 5 |
9360-4PX | 42U 1200mm Deep Dynamic Rack | Yes | 5 |
9360-4EX | 42U 1200mm Deep Dynamic Expansion Rack | Yes | 5 |
9361-4PX | 42U 1200mm Deep Static Rack | Yes | 5 |
9361-4EX | 42U 1200mm Deep Static Expansion Rack | Yes | 5 |
9362-4PX | 47U 1200mm Deep Static Rack | Yes | 5 |
9362-4EX | 47U 1200mm Deep Static Expansion Rack | Yes | 5 |
9363-4CX | PureFlex System 42U Rack | Yes | 5 |
9363-4DX | PureFlex System 42U Expansion Rack | Yes | 5 |
9363-4PX | 42U 1100mm Dynamic Rack | Yes | 5 |
9363-4EX | 42U 1100mm Dynamic Expansion Rack | Yes | 5 |
1410-2RX | Intelligent Cluster 25U Rack Family | No | Not applicable |
1410-4RX | Intelligent Cluster 42U Rack Family | Yes* | 5 |
1410-PRA | Intelligent Cluster 42U 1200mm Deep Rack Family | Yes | 5 |
1410-PRB | Intelligent Cluster 42U 1100mm Enterprise V2 Rack Family | Yes | 5 |
7200-4PX | Smart Analytics 42U Rack Family | Yes* | 5 |
* No support for Full-length I/O Books
For more information, see the list of Lenovo Press Product Guides in the Rack cabinets category:
https://lenovopress.com/servers/options/racks
KVM console options
The following table lists the supported KVM consoles, keyboards, and KVM switches.
Part number | Description |
Consoles | |
17238BX | 1U 18.5" Standard Console (without keyboard) |
Console keyboards | |
00MW310 | Lenovo UltraNav Keyboard USB - US Eng |
46W6713 | Keyboard w/ Int. Pointing Device USB - Arabic 253 RoHS v2 |
46W6714 | Keyboard w/ Int. Pointing Device USB - Belg/UK 120 RoHS v2 |
46W6715 | Keyboard w/ Int. Pointing Device USB - Chinese/US 467 RoHS v2 |
46W6716 | Keyboard w/ Int. Pointing Device USB - Czech 489 RoHS v2 |
46W6717 | Keyboard w/ Int. Pointing Device USB - Danish 159 RoHS v2 |
46W6718 | Keyboard w/ Int. Pointing Device USB - Dutch 143 RoHS v2 |
46W6719 | Keyboard w/ Int. Pointing Device USB - French 189 RoHS v2 |
46W6720 | Keyboard w/ Int. Pointing Device USB - Fr/Canada 445 RoHS v2 |
46W6721 | Keyboard w/ Int. Pointing Device USB - German 129 RoHS v2 |
46W6722 | Keyboard w/ Int. Pointing Device USB - Greek 219 RoHS v2 |
46W6723 | Keyboard w/ Int. Pointing Device USB - Hebrew 212 RoHS v2 |
46W6724 | Keyboard w/ Int. Pointing Device USB - Hungarian 208 RoHS v2 |
46W6725 | Keyboard w/ Int. Pointing Device USB - Italian 141 RoHS v2 |
46W6726 | Keyboard w/ Int. Pointing Device USB - Japanese 194 RoHS v2 |
46W6727 | Keyboard w/ Int. Pointing Device USB - Korean 413 RoHS v2 |
46W6728 | Keyboard w/ Int. Pointing Device USB - LA Span 171 RoHS v2 |
46W6729 | Keyboard w/ Int. Pointing Device USB - Norwegian 155 RoHS v2 |
46W6730 | Keyboard w/ Int. Pointing Device USB - Polish 214 RoHS v2 |
46W6731 | Keyboard w/ Int. Pointing Device USB - Portuguese 163 RoHS v2 |
46W6732 | Keyboard w/ Int. Pointing Device USB - Russian 441 RoHS v2 |
46W6733 | Keyboard w/ Int. Pointing Device USB - Slovak 245 RoHS v2 |
46W6734 | Keyboard w/ Int. Pointing Device USB - Spanish 172 RoHS v2 |
46W6735 | Keyboard w/ Int. Pointing Device USB - Swed/Finn 153 RoHS v2 |
46W6736 | Keyboard w/ Int. Pointing Device USB - Swiss F/G 150 RoHS v2 |
46W6737 | Keyboard w/ Int. Pointing Device USB - Thai 191 RoHS v2 |
46W6738 | Keyboard w/ Int. Pointing Device USB - Turkish 179 RoHS v2 |
46W6739 | Keyboard w/ Int. Pointing Device USB - UK Eng 166 RoHS v2 |
46W6740 | Keyboard w/ Int. Pointing Device USB - US Euro 103P RoHS v2 |
46W6741 | Keyboard w/ Int. Pointing Device USB - Slovenian 234 RoHS v2 |
Console switches | |
1754D2X | Global 4x2x32 Console Manager (GCM32) |
1754D1X | Global 2x2x16 Console Manager (GCM16) |
1754A2X | Local 2x16 Console Manager (LCM16) |
1754A1X | Local 1x8 Console Manager (LCM8) |
Console switch cables | |
43V6147 | Single Cable USB Conversion Option (UCO) |
39M2895 | USB Conversion Option (4 Pack UCO) |
46M5383 | Virtual Media Conversion Option Gen2 (VCO2) |
46M5382 | Serial Conversion Option (SCO) |
For more information, see the list of Product Guides in the KVM Switches and Consoles category:
http://lenovopress.com/servers/options/kvm
Lenovo Financial Services
Why wait to obtain the technology you need now? No payments for 90 days and predictable, low monthly payments make it easy to budget for your Lenovo solution.
- Flexible
Our in-depth knowledge of the products, services and various market segments allows us to offer greater flexibility in structures, documentation and end of lease options.
- 100% Solution Financing
Financing your entire solution including hardware, software, and services, ensures more predictability in your project planning with fixed, manageable payments and low monthly payments.
- Device as a Service (DaaS)
Leverage latest technology to advance your business. Customized solutions aligned to your needs. Flexibility to add equipment to support growth. Protect your technology with Lenovo's Premier Support service.
- 24/7 Asset management
Manage your financed solutions with electronic access to your lease documents, payment histories, invoices and asset information.
- Fair Market Value (FMV) and $1 Purchase Option Leases
Maximize your purchasing power with our lowest cost option. An FMV lease offers lower monthly payments than loans or lease-to-own financing. Think of an FMV lease as a rental. You have the flexibility at the end of the lease term to return the equipment, continue leasing it, or purchase it for the fair market value. In a $1 Out Purchase Option lease, you own the equipment. It is a good option when you are confident you will use the equipment for an extended period beyond the finance term. Both lease types have merits depending on your needs. We can help you determine which option will best meet your technological and budgetary goals.
Ask your Lenovo Financial Services representative about this promotion and how to submit a credit application. For the majority of credit applicants, we have enough information to deliver an instant decision and send a notification within minutes.
Related product families
Product families related to this document are the following:
Trademarks
Lenovo and the Lenovo logo are trademarks or registered trademarks of Lenovo in the United States, other countries, or both. A current list of Lenovo trademarks is available on the Web at https://www.lenovo.com/us/en/legal/copytrade/.
The following terms are trademarks of Lenovo in the United States, other countries, or both:
Lenovo®
ServerProven®
System x®
ThinkAgile®
ThinkServer®
ThinkSystem®
UltraNav®
X-Architecture®
XClarity®
The following terms are trademarks of other companies:
Intel® and Xeon® are trademarks of Intel Corporation or its subsidiaries.
Linux® is the trademark of Linus Torvalds in the U.S. and other countries.
Microsoft®, PowerShell, Windows PowerShell®, Windows Server®, and Windows® are trademarks of Microsoft Corporation in the United States, other countries, or both.
Other company, product, or service names may be trademarks or service marks of others.