Abstract

The Lenovo RackSwitch™ G8272 is a cost-effective, enterprise class 10/40 Gb Ethernet solution that delivers exceptional performance, being lossless and low latency. The G8272 also delivers excellent cost savings as you consider acquisition costs, energy costs, operational expenses, and ease of use and management. It has a feature-rich design with key virtualization features, such as CEE/FCoE, high availability, and enterprise class Layer 2 and Layer 3 functionality.

The RackSwitch G8272 supports 10 Gb and 40 Gb Ethernet. With 1.44 Tbps throughput, the G8272 provides massive scalability and low latency, which is ideal for latency-sensitive applications, such as high-performance computing clusters and financial applications.

This product guide provides essential pre-sales information to understand the structure of the RackSwitch G8272 offering, its key features and specifications, components and options, and configuration guidelines.

This guide is intended for technical specialists, sales specialists, sales engineers, IT architects, and other IT professionals who want to learn more about the RackSwitch G8272 and consider its use in IT solutions.

Withdrawn from marketing: This networking switch is now withdrawn from marketing.

Introduction

The Lenovo RackSwitch™ G8272 that uses 10 Gb SFP+ and 40 Gb QSFP+ Ethernet technology is specifically designed for the data center. It is ideal for today's big data, cloud, and optimized workload solutions. It is an enterprise class Layer 2 and Layer 3 full featured switch that delivers line-rate, high-bandwidth switching, filtering, and traffic queuing without delaying data. Large data center-grade buffers help keep traffic moving, while the hot-swap redundant power supplies and fans (along with numerous high-availability features) help provide high availability for business sensitive traffic.

The RackSwitch G8272 is ideal for latency sensitive applications, such as high-performance computing clusters and financial applications. In addition to the 10 Gb Ethernet (GbE) and 40 GbE connections, the G8272 can use 1 GbE connections.

The RackSwitch G8272 is shown in the following figure.

Lenovo RackSwitch G8272
Figure 1. Lenovo RackSwitch G8272

Did you know?

With exceptional port density and flexibility with break-out cables, the RackSwitch G8272 can support up to 72x 10 Gb Ethernet connections in a 1U rack form factor.

The RackSwitch G8272 offers a choice of the Networking Operating Systems (NOS):

  • The Cloud NOS provides a simple, open and programmable network infrastructure with cloud-scale performance. It delivers a software-defined Ethernet solution that is simple to manage and easy to deploy using common management tools, and it enables support of automation and orchestration applications for tight integration into the data center ecosystem.
  • The Enterprise NOS is a data center-class NOS progressively developed over the past decade to deliver highly reliable, high-performance Ethernet and converged switching and interoperability with existing network infrastructures. ENOS has a feature-rich design with virtualization, high availability, and enterprise class Layer 2 and Layer 3 functionality. ENOS supports OpenFlow which helps easily create software defined virtual networks (SDN) and enables a remote controller to modify the behavior of network devices.

The RackSwitch G8272 supports the Open Network Install Environment (ONIE) which is a small Linux-based operating system that provides an open install environment for networking devices without operating systems. 

Key features

The RackSwitch G8272 is considered particularly suited for the following environments:

  • 10 GbE server connectivity with 40 GbE upstream aggregation
  • Virtualized environments with VM-aware networking
  • Converged SAN and LAN network via NAS, iSCSI, or FCoE
    • Reduced I/O cost (CAPEX) with fewer adapters, cables, and transceivers to purchase
    • Reduced complexity (OPEX) with fewer components to manage and lower energy cost
  • Accelerated communications with lower latency across clustered applications and storage arrays with RDMA over Converged Ethernet (RoCE)
  • Investment protection with 40 Gb Ethernet, Cloud, and SDN

The RackSwitch G8272 offers the following features and benefits:

  • High performance

    The 10 Gb/40 Gb switch provides the best combination of low latency, non-blocking line-rate switching, and ease of management. It has a throughput of 1.44 Tbps.

  • Lower power and better cooling

    The RackSwitch G8272 uses as little as 123 W of power, which is less than comparable switches use. The front-to-rear or rear-to-front cooling design of the RackSwitch G8272 reduces data center air conditioning costs by having airflow match the servers in the rack. In addition, variable speed fans help to automatically reduce power consumption.

  • Layer 3 functionality

    The RackSwitch G8272 includes Layer 3 functionality, which provides security and performance benefits, as inter-VLAN traffic stays within the switch. This switch also provides the full range of Layer 3 protocols from static routes for technologies, such as Open Shortest Path First (OSPF) and Border Gateway Protocol (BGP) for enterprise customers.

  • Network virtualization

    The RackSwitch G8272 switch supports VXLAN Gateway for VMware NSX integration. VMware NSX is a virtualized network software platform that offers a full set of networking services, such as logical switching, routing, firewall, load balancing, VPN, quality of service (QoS), and monitoring.

  • Converged fabric

    The RackSwitch G8272 switch supports Converged Enhanced Ethernet (CEE) which helps enable customers to combine storage, messaging traffic, VoIP, video, and other data on a common data center lossless Ethernet infrastructure. As a result, clients can deploy a single server interface for multiple data types, which can simplify the deployment and management of server network connectivity while maintaining the high availability and robustness that is required for storage transactions.

  • Seamless interoperability

    RackSwitch switches perform seamlessly with other vendors' upstream switches.

  • Fault tolerance

    The RackSwitch G8272 offers redundant hot-swap hardware components, learns alternate routes automatically, and performs faster convergence if there is a link, switch, or power failure.

  • Open Network Install Environment (ONIE) (Requires an optional license key)

    The ONIE is a small Linux-based operating system that provides an open install environment for networking devices without operating systems. ONIE enables a network switch ecosystem for end users to choose among different Network Operating Systems by discovering NOS installer images and loading them onto the switch.

The RackSwitch G8272 supports the following networking operating systems:

  • Lenovo Cloud Networking Operating System (CNOS)

    The new Cloud NOS provides a simple, open and programmable network infrastructure designed to scale for your business needs. Its intelligent, cloud-scale performance delivers a software-defined Ethernet solution that is simple to manage and easy to deploy using common management tools. Cloud NOS is based on open, industry standards for better data center interoperability, and it enables support of automation and orchestration applications for tight integration into the data center ecosystem.

    With its high-performance architecture and support for an extensive set of routing protocols, Cloud NOS provides reliable, high-performance fabric for traditional, converged and hyperscale solutions. Cloud NOS can help you consolidate server and storage networks into a single fabric. Converged Enhanced Ethernet delivers value for your iSCSI and NAS enterprise storage environments.

  • Lenovo Enterprise Networking Operating System (ENOS)

    The Lenovo ENOS is a data center-class network operating system progressively developed over the past decade to deliver highly reliable, high-performance Ethernet and converged switching and interoperability with existing network infrastructures. 

    ENOS has a feature-rich design with virtualization, UFP, high availability, and enterprise class Layer 2 and Layer 3 functionality. ENOS supports OpenFlow which helps easily create software defined virtual networks (SDN) and enables a remote controller to modify the behavior of network devices.

    ENOS can help you consolidate server and storage networks into a single fabric. Converged Enhanced Ethernet delivers value for your iSCSI, NAS and FCoE enterprise storage environments.

The RackSwitch G8272 with Cloud NOS offers the following additional features:

  • Automated VM-aware network provisioning

    The Lenovo CNOS Network Policy Agent, a ThinkAgile Network Orchestrator feature, gives increased visibility of the Nutanix (AOS version 5.0.2 or higher [excluding 5.1.2]) and VMware vSphere virtual infrastructure, including VM and virtual network information. It provides automated VM-aware provisioning by automatically configuring VLANs in the physical network based on the auto-discovered virtual network topology. The agent also performs ongoing dynamic updates to the physical network configuration in response to new VMs, updated VMs, and deleted VMs and virtual networks, eliminating errors with manual configuration.

  • Pro-active congestion monitoring

    Telemetry enables continuous monitoring of networking devices to detect potential congestion problems, such as packets dropped by the switch when ports are being used close to their line rate or switch buffers are being temporarily overflown (for example, in case of microbursts).

  • Zero Touch Provisioning

    Zero Touch Provisioning (ZTP) enables a switch to automatically provision itself using the resources available on the network, without manual intervention. ZTP automatically handles the process of upgrading the switch software image and installing configuration files.

  • Python Scripting

    You can create and execute local Python scripts on switches to make small programs that allow a switch to automatically provision itself, perform fault monitoring, upgrade the image files, or auto-generate configuration files. You can implement version control systems, automatically generate alerts, create custom logging tools, and automate the management of network devices.

  • REST API Programming

    The Lenovo REpresentational State Transfer (REST) Application Program Interface (API) enables you to remotely configure and manage a Lenovo switch using REST and HyperText Transfer Protocol (HTTP). It also allows switch management integration into management applications, such as Lenovo XClarity.

The RackSwitch G8272 with Enterprise NOS offers the following additional features:

  • Virtual Fabric

    The RackSwitch G8272 can help customers address I/O requirements for multiple NICs while reducing cost and complexity. By using Unified Fabric Port, you can carve a physical NIC into multiple virtual ports (2 - 8 vPorts) and create a virtual pipe between the adapter and the switch for improved performance, availability, and security.

  • Transparent networking capability

    With a simple configuration change to Easy Connect Mode, the RackSwitch G8272 becomes a transparent network device that is invisible to the core and eliminates network administration concerns of Spanning Tree Protocol configuration and interoperability and VLAN assignments and avoids any possible loops. By emulating a host NIC to the data center core, it accelerates the provisioning of VMs by eliminating the need to configure the typical access switch parameters.

  • OpenFlow enabled

    The RackSwitch G8272 offers benefits of OpenFlow. OpenFlow is the open API that enables the network administrator to easily configure and manage virtual networks that control traffic on a “per-flow” basis. It creates multiple independent virtual networks and related policies without dealing with the complexities of the underlying physical network and protocols. The RackSwitch G8272 is also the ideal switch to use with industry compliant OpenFlow controllers.

The following table compares high level features of the CNOS and ENOS.

Table 1. CNOS and ENOS high level feature comparison
Feature CNOS ENOS
Layer 2 switching Yes Yes
Layer 3 switching Yes Yes
EasyConnect mode Yes Yes
IP routing Yes Yes
Comprehensive IP v6 support Yes No*
Unified Fabric Port No Yes
Converged Enhanced Ethernet Yes Yes
OpenFlow SDN No Yes
Automated VM-aware network provisioning** Yes No
Real-time congestion monitoring with telemetry Yes No
Zero touch provisioning Yes No
REST API programming Yes No
Python scripting Yes Yes

* Not all ENOS features support IP v6 addressing, including DHCP, BGP, VRRP, and TACACS+/RADIUS/LDAP.
** Supported with the Nutanix AOS version 5.0.2 or higher (excluding 5.1.2) or VMware vSphere.

Components and connectors

The following figure shows the front panel of the RackSwitch G8272.

Front panel of the RackSwitch G8272
Figure 2. Front panel of the RackSwitch G8272

The front panel of the RackSwitch G8272 includes the following components:

  • LEDs that display the status of the switch and the network.
  • One Mini-USB RS-232 console port that provides another means to configure the switch.
  • One USB port for mass storage devices.
  • 48x SFP/SFP+ ports to attach SFP/SFP+ transceivers for 1 Gb or 10 Gb Ethernet connections or DAC cables for 10 Gb Ethernet connections.
  • 6x QSFP+ ports to attach QSFP+ transceivers or DAC cables for 40 Gb or 4x 10 Gb Ethernet connections.
  • One RJ-45 10/100/1000 Mb Ethernet port for out-of-band management.

The following figure shows the rear panel of the RackSwitch G8272.

Rear panel of the RackSwitch G8272
Figure 3. Rear panel of the RackSwitch G8272

The rear panel of the RackSwitch G8272 includes the following components:

  • Two redundant hot-swap AC power supplies (IEC 320-C14 power connector)
  • Four 3+1 redundant hot-swap fan assemblies

System specifications

The following table lists the RackSwitch G8272 system specifications.

Note: The supported hardware options and software features listed in this product guide are based on the Lenovo Cloud Networking Operating System (CNOS) version 10.9 or Lenovo Enterprise Networking Operating System (ENOS) version 8.4.4. For details about specific software releases that introduced support for certain hardware options and software features, refer to the Release Notes for the particular software release that can be found at:
http://systemx.lenovofiles.com/help/topic/com.lenovo.rackswitch.g8272.doc/rs_g8272.html

Table 2. System specifications
Attribute Specification
Form factor 1U rack mount
Ports
  • 48x SFP/SFP+ ports
  • 6x QSFP+ ports
Media types 40 Gb Ethernet QSFP+:
  • 40 GbE short-range (SR) QSFP+ bi-directional (BiDi) transceivers
  • 40 GbE short-range (SR4/iSR4/eSR4) QSFP+ transceivers
  • 40 GbE long-range (LR4) QSFP+ transceivers
  • 40 GbE QSFP+ to QSFP+ active optical cables (AOCs)
  • 40 GbE QSFP+ to 4x 10 GbE SFP+ active optical breakout cables
  • 40 GbE QSFP+ to QSFP+ direct attach copper (DAC) cables
  • 40 GbE QSFP+ to 4x 10 GbE SFP+ DAC breakout cables
10 Gb Ethernet SFP+:
  • 10 GbE short-range (SR) SFP+ transceivers
  • 10 GbE long-range (LR) SFP+ transceivers
  • 10 GbE extended-range (ER) SFP+ transceivers
  • 10 GbE RJ-45 SFP+ transceivers
  • 10 GbE SFP+ active optical cables
  • 10 GbE SFP+ DAC cables
1/10 Gb Ethernet SFP+:
  • 1/10 GbE SX/SR SFP+ transceivers
1 Gb Ethernet SFP:
  • 1 GbE short-wavelength (SX) SFP transceivers
  • 1 GbE long-wavelength (LX) SFP transceivers
  • 1 GbE RJ-45 SFP transceivers
Port speeds
  • 40 GbE QSFP+ SR BiDi/SR4/LR4 transceivers: 40 GbE
  • 40 GbE QSFP+ iSR4/eSR4 transceivers, DAC cables and AOCs: 40 GbE or 4x 10 GbE
  • 10 GbE SFP+ transceivers, DAC cables and AOCs: 10 Gbps
  • 1/10 GbE SFP+ transceivers: 1 Gbps or 10 Gbps
  • 1 GbE SFP transceivers: 1 Gbps
Switching method Cut-through.
Data traffic types Unicast, multicast, broadcast.
Software features
  • Lenovo Enterprise Networking OS (ENOS):
    Layer 2 switching, Layer 3 switching, virtual local area networks (VLANs), VLAN tagging, spanning tree protocol (STP), link aggregation (trunk) groups (LAGs), virtual LAGs (vLAGs), Hot Links, Layer 2 failover, quality of service (QoS), Edge Virtual Bridging (EVB), VMready, OpenFlow, IPv4/IPv6 management, IPv4/IPv6 routing, equal cost multiple paths (ECMP), IPv4 virtual router redundancy protocol (VRRP), IPv4 policy-based routing (PBR), Unified Fabric Port (UFP), Converged Enhanced Ethernet, Fibre Channel over Ethernet (FCoE) transit switch operations, VXLAN gateway.
  • Lenovo Cloud Networking OS (CNOS):
    Layer 2 switching, Layer 3 switching, virtual local area networks (VLANs), VLAN tagging, spanning tree protocol (STP), link aggregation (trunk) groups (LAGs), virtual LAGs (vLAGs), Layer 2 failover, quality of service (QoS), IPv4/IPv6 management, IPv4/IPv6 routing, equal cost multiple paths (ECMP), IPv4/IPv6 virtual router redundancy protocol (VRRP), IPv4 policy-based routing (PBR), Converged Enhanced Ethernet (CEE), Network Policy Agent, VXLAN gateway, Python scripting, REST API programming.
Performance Non-blocking architecture with wire-speed forwarding of traffic:
  • 100% line-rate performance
  • Up to 1.44 Tbps aggregated throughput
  • As low as 600 nanoseconds switching latency
  • Up to 1071 Million packets per second (Mpps) (64-byte packets)
  • Up to 9,216-byte jumbo frames
  • Receive buffer size: 12.2 MB
Scalability
  • MAC address forwarding database entries: 224,000
  • VLANs: 4,095 (3,999 user-configurable; 96 reserved)
  • Per VLAN Rapid Spanning Tree (PVRST) instances: 256 (ENOS) / 500 (CNOS)
  • Multiple STP (MSTP) instances: 32 (ENOS) / 64 (CNOS)
  • Link aggregation groups: 72
  • Active ports in a link aggregation group: 32
  • Static routes (IPv4 / IPv6):
    • ENOS: 128 / 128
    • CNOS: 256 / 256
  • Dynamic routes (IPv4 / IPv6):
    • ENOS: 15,538 / 600
    • CNOS: 15,870 / 6,143
Cooling Four 3+1 redundant hot-swap fans. Rear (non-port side) to front (port side) or front to rear airflow.
Power supply Two load-sharing, redundant hot-swap 460 W AC (100 - 240 V) Gold power supplies (1x IEC 320-C14 connector on each power supply).
Hot-swap parts SFP/SFP+/QSFP+ transceivers, SFP+/QSFP+ DAC cables, power supplies, fans.
Management ports 1x 10/100/1000 Mb Ethernet port (RJ-45); 1x RS-232 port (Mini-USB); 1x USB port (for additional firmware, log, and configuration files storage).
Management interfaces Industry standard command line interface (isCLI); SNMP v1, V2, and v3; Netconf (XML) (ENOS only); REST API (CNOS only). Optional Lenovo XClarity for discovery, inventory, monitoring and events. Optional Lenovo Networking Content Pack for VMware vRealize Log Insight.
Security features Secure Shell (SSH); Secure Copy (SCP); Secure FTP (sFTP); user level security; Role-based Access Control (RBAC); LDAP/LDAPS, RADIUS, and TACACS+ authentication; access control lists (ACLs); port-based network access control (IEEE 802.1x; ENOS only); secure mode.
Hardware warranty Three-year customer-replaceable unit and onsite limited warranty with 9x5 next business day terms. Optional warranty service upgrades are available through Lenovo: onsite service, 24x7 coverage, 2-hour or 4-hour response time, 1-year or 2-year warranty extensions, basic installation services.
Software maintenance Three-year software support and subscription is included in the base warranty. Optional 1-year and 2-year warranty extensions include software support and subscription.
Mean Time Between Failures 290,023 hours MTBF with ambient operating temperature of 40° C.
Dimensions Height: 44 mm (1.7 in.); width: 439 mm (17.3 in.); depth: 487 mm (19.2 in.)
Weight 9.1 kg (20.0 lb).

Models

The following table lists the G8272 switch models.

Table 3. G8272 switch models
Description Part number Machine Type-Model Feature code
Lenovo RackSwitch G8272 (Rear to Front) 7159CRW 7159-HCW ASRD
Lenovo RackSwitch G8272 (Front to Rear) 7159CFV 7159-HCV ASRE

The part numbers for the G8272 switches include the following items:

  • One Lenovo RackSwitch G8272 with two power supplies and four fan assemblies (rear-to-front airflow or front-to-rear airflow)
  • Generic Rack Mount Kit (2-post)
  • Console Cable Kit that includes the following items:
    • RJ-45 (plug) to RJ-45 (plug) serial cable (1 m)
    • Mini-USB to RJ-45 (jack) adapter cable (0.2 m) with retention clip
    • DB-9 to RJ-45 (jack) adapter
  • Documentation package

Configuration notes:

  • Power cables are not included and must be ordered together with the switch (see "Power supplies and cables" for details).
  • QSFP+ and SFP/SFP+ transceivers and cables are not included and should be ordered together with the switch (see "Transceivers and cables" for details).

The RackSwitch G8272 supports Features on Demand (FoD) license keys to enable additional features. The ONIE FoD option enables customers to download an ONIE boot loader and install it on the switch, and the Advanced Instrumentation Tools FoD option enables access to low-level switch diagnostics for advanced troubleshooting.

The following table lists the FoD upgrade options for the RackSwitch G8272.

Table 4. FoD upgrade options
Description Part number Feature code
Lenovo RackSwitch G8272 ONIE Open Switch OS Installer 00YL963 AUE2
Lenovo RackSwitch G8272 Advanced Instrumentation Tools 00YL029* AUE1*

* Supported only for Cloud NOS.

Transceivers and cables

With the flexibility of the G8272 switch, customers can choose the following connectivity technologies:

  • For 1 GbE links, customers can use RJ-45 SFP transceivers with UTP cables up to 100 meters. Customers that need longer distances can use a 1000BASE-SX transceiver, which can drive distances up to 220 meters with 62.5 µ multimode fiber (OM1) and up to 550 meters with 50 µ multimode fiber (OM2), or the 1000BASE-LX transceivers that support distances up to 10 kilometers with single-mode fiber (1310 nm).
  • For 10 GbE links, customers can use SFP+ direct-attached copper (DAC) cables for in-rack cabling for distances up to 7 meters or SFP+ active optical cables (AOCs) for distances up to 20 meters. These cables have SFP+ connectors on each end, and they do not need separate transceivers. For distances up to 30 meters, the 10GBASE-T SFP+ transceiver can be used with Category 6a or 7 RJ-45 UTP cables.

    For longer distances, the 10GBASE-SR transceiver supports distances up to 300 meters over OM3 multimode fiber or up to 400 meters over OM4 multimode fiber. The 10GBASE-LR transceivers can support distances up to 10 kilometers on single mode fiber. For extended distances, the 10GBASE-ER transceivers can support distances up to 40 kilometers on single mode fiber.

    To increase the number of available 10 GbE ports, customers can split out four 10 GbE ports for each 40 GbE port by using QSFP+ to 4x SFP+ DAC or active optical breakout cables for distances up to 5 meters. For distances up to 100 meters, the 40GBASE-iSR4 QSFP+ transceivers can be used with OM3 optical MPO-to-LC breakout cables or up to 150 meters with OM4 optical MPO-to-LC breakout cables. For longer distances, the 40GBASE-eSR4 transceivers can be used with OM3 optical MPO-to-LC breakout cables for distances up to 300 meters or OM4 optical MPO-to-LC breakout cables for distances up to 400 meters.

  • For 40 GbE to 40 GbE connectivity, customers can use the affordable QSFP+ to QSFP+ DAC cables for distances up to 7 meters or QSFP+ to QSFP+ active optical cables for distances up to 20 meters. These DAC cables and AOCs have QSFP+ connectors on each end, and they do not need separate transceivers.

    With multimode fiber LC cables, customers can use the 40GBASE QSFP+ bi-directional transceivers for distances up to 100 meters with OM3 MMF LC cables or up to 150 meters with OM4 MMF LC cables.

    With multimode fiber MPO cables, customers can use the 40GBASE-SR4/iSR4 QSFP+ transceivers for distances up to 100 meters with OM3 MMF MPO cables or up to 150 meters with OM4 MMF MPO cables. For distances up to 300 meters, the 40GBASE-eSR4 QSFP+ transceiver can be used with OM3 MMF MPO cables or up to 400 meters with OM4 MMF MPO cables.

    For distances up to 10 kilometers, the 40GBASE-LR4 QSFP+ transceiver can be used with single mode fiber LC cables.

The following table lists the supported cables and transceivers.

Table 5. Supported SFP/SFP+ transceivers and DAC cables
Description Part number Feature code Maximum quantity
SFP transceivers - 1 GbE
Lenovo 1000BASE-T (RJ-45) SFP Transceiver (no 10/100 Mbps support) 00FE333 A5DL 48
Lenovo 1000BASE-SX SFP Transceiver 81Y1622 3269 48
Lenovo 1000BASE-LX SFP Transceiver 90Y9424 A1PN 48
UTP Category 5E cables for 1 GbE SFP RJ-45 transceivers and 1 GbE RJ-45 management ports
0.6m Green Cat5e Cable 40K5563 3796 49
1.5m Blue Cat5e Cable 40K8785 3802 49
1.5m Green Cat5e Cable 40K5643 3797 49
3m Blue Cat5e Cable 40K5581 3803 49
3m Green Cat5e Cable 40K5793 3798 49
3m Yellow Cat5e Cable 40K8957 3793 49
10m Blue Cat5e Cable 40K8927 3804 49
10m Green Cat5e Cable 40K5794 3799 49
25m Blue Cat5e Cable 40K8930 3805 49
25m Green Cat5e Cable 40K8869 3800 49
SFP+ transceivers - 10 GbE
Lenovo Dual Rate 1/10Gb SX/SR SFP+ Transceiver 00MY034 ATTJ 48
Lenovo 10Gb SFP+ SR Transceiver (10GBASE-SR) 46C3447 5053 48
Lenovo 10Gb SFP+ LR Transceiver (10GBASE-LR) 90Y9412 A1PM 48
Lenovo 10GBASE-LR SFP+ Transceiver 00FE331 B0RJ 48
Lenovo 10Gb SFP+ ER Transceiver (10GBASE-ER) 90Y9415 A1PP 10
Lenovo 10GBASE-T SFP+ Transceiver 7G17A03130 AVV1 48
Optical cables for 1 GbE SX SFP, 10 GbE SR SFP+, and 40 GbE SR QSFP+ BiDi transceivers
Lenovo 0.5m LC-LC OM3 MMF Cable 00MN499 ASR5 48
Lenovo 1m LC-LC OM3 MMF Cable 00MN502 ASR6 48
Lenovo 3m LC-LC OM3 MMF Cable 00MN505 ASR7 48
Lenovo 5m LC-LC OM3 MMF Cable 00MN508 ASR8 48
Lenovo 10m LC-LC OM3 MMF Cable 00MN511 ASR9 48
Lenovo 15m LC-LC OM3 MMF Cable 00MN514 ASRA 48
Lenovo 25m LC-LC OM3 MMF Cable 00MN517 ASRB 48
Lenovo 30m LC-LC OM3 MMF Cable 00MN520 ASRC 48
UTP Category 6 cables for 1 GbE SFP and 10 GbE SFP+ RJ-45 transceivers, and 1 GbE RJ-45 management ports
10m Cat6 Blue Cable 90Y3721 A1MU 49
10m Cat6 Green Cable 90Y3718 A1MT 49
10m Cat6 Yellow Cable 90Y3715 A1MS 49
25m Cat6 Blue Cable 90Y3730 A1MX 49
25m Cat6 Green Cable 90Y3727 A1MW 49
25m Cat6 Yellow Cable 90Y3724 A1MV 49
SFP+ active optical cables - 10 GbE
Lenovo 1m SFP+ to SFP+ Active Optical Cable 00YL634 ATYX 48
Lenovo 3m SFP+ to SFP+ Active Optical Cable 00YL637 ATYY 48
Lenovo 5m SFP+ to SFP+ Active Optical Cable 00YL640 ATYZ 48
Lenovo 7m SFP+ to SFP+ Active Optical Cable 00YL643 ATZ0 48
Lenovo 15m SFP+ to SFP+ Active Optical Cable 00YL646 ATZ1 48
Lenovo 20m SFP+ to SFP+ Active Optical Cable 00YL649 ATZ2 48
SFP+ passive direct-attach cables - 10 GbE
Lenovo 0.5m Passive SFP+ DAC Cable 00D6288 A3RG 48
Lenovo 1m Passive SFP+ DAC Cable 90Y9427 A1PH 48
Lenovo 1.5m Passive SFP+ DAC Cable 00AY764 A51N 48
Lenovo 2m Passive SFP+ DAC Cable 00AY765 A51P 48
Lenovo 3m Passive SFP+ DAC Cable 90Y9430 A1PJ 48
Lenovo 5m Passive SFP+ DAC Cable 90Y9433 A1PK 48
Lenovo 7m Passive SFP+ DAC Cable 00D6151 A3RH 48
SFP+ active direct-attach cables - 10 GbE
Lenovo 1m Active DAC SFP+ Cable 00VX111 AT2R 48
Lenovo 3m Active DAC SFP+ Cable 00VX114 AT2S 48
Lenovo 5m Active DAC SFP+ Cable 00VX117 AT2T 48
QSFP+ transceivers - 40 GbE
Lenovo 40GBase QSFP+ Bi-Directional Transceiver 00YL631 ATYW 4*
Lenovo 40GBASE-SR4 QSFP+ Transceiver 49Y7884 A1DR 6
Lenovo 40GBASE-iSR4 QSFP+ Transceiver 00D9865 ASTM 6
Lenovo 40GBASE-eSR4 QSFP+ Transceiver 00FE325 A5U9 6
Lenovo 40GBASE-LR4 QSFP+ Transceiver 00D6222 A3NY 6
Optical cables for 40 GbE QSFP+ SR4/iSR4/eSR4 transceivers
Lenovo 10m QSFP+ MPO-MPO OM3 MMF Cable 00VX003 AT2U 6
Lenovo 30m QSFP+ MPO-MPO OM3 MMF Cable 00VX005 AT2V 6
Optical breakout cables for 40 GbE QSFP+ iSR4/eSR4 transceivers
Lenovo 1m MPO-4xLC OM3 MMF Breakout Cable 00FM412 A5UA 6
Lenovo 3m MPO-4xLC OM3 MMF Breakout Cable 00FM413 A5UB 6
Lenovo 5m MPO-4xLC OM3 MMF Breakout Cable 00FM414 A5UC 6
QSFP+ active optical cables - 40 GbE
Lenovo 1m QSFP+ to QSFP+ Active Optical Cable 7Z57A04256 AX42 6
Lenovo 3m QSFP+ to QSFP+ Active Optical Cable 00YL652 ATZ3 6
Lenovo 5m QSFP+ to QSFP+ Active Optical Cable 00YL655 ATZ4 6
Lenovo 7m QSFP+ to QSFP+ Active Optical Cable 00YL658 ATZ5 6
Lenovo 15m QSFP+ to QSFP+ Active Optical Cable 00YL661 ATZ6 6
Lenovo 20m QSFP+ to QSFP+ Active Optical Cable 00YL664 ATZ7 6
QSFP+ active optical breakout cables - 40 GbE to 4x10 GbE
Lenovo 1M QSFP+ to 4xSFP+ Active Optical Cable 00YL667 ATZ8 6
Lenovo 3M QSFP+ to 4xSFP+ Active Optical Cable 00YL670 ATZ9 6
Lenovo 5M QSFP+ to 4xSFP+ Active Optical Cable 00YL673 ATZA 6
QSFP+ direct-attach cables - 40 GbE
Lenovo 1m Passive QSFP+ DAC Cable 49Y7890 A1DP 6
Lenovo 3m Passive QSFP+ DAC Cable 49Y7891 A1DQ 6
Lenovo 5m Passive QSFP+ DAC Cable 00D5810 A2X8 6
Lenovo 7m Passive QSFP+ DAC Cable 00D5813 A2X9 6
QSFP+ breakout cables - 40 GbE to 4x 10 GbE
Lenovo 1m Passive QSFP+ to SFP+ Breakout DAC Cable 49Y7886 A1DL 6
Lenovo 3m Passive QSFP+ to SFP+ Breakout DAC Cable 49Y7887 A1DM 6
Lenovo 5m Passive QSFP+ to SFP+ Breakout DAC Cable 49Y7888 A1DN 6
Spare console cables
Console Cable Kit Spare (RJ-45/DB9) 90Y9462 A2MG 1

* 40 GbE QSFP+ Bi-Directional transceivers are supported in port 49, 50, 53, and 54.

The network cables that can be used with the switch are listed in the following table.

Table 6. G8272 network cabling requirements
Transceiver Standard Cable Connector
40 Gb Ethernet
40Gb SR QSFP+ BiDi (00YL631) 40GBASE-SR BiDi Up to 30 m with fiber optic cables supplied by Lenovo (see Table 3); up to 100 m with OM3 or up to 150 m with OM4 multimode fiber optic cable LC
40Gb SR4 QSFP+ (49Y7884) 40GBASE-SR4 10 m or 30 m MPO fiber optic cables supplied by Lenovo (see Table 3); support for up to 100 m with OM3 or up to 150 m with OM4 multimode fiber optic cable MPO
40Gb iSR4 QSFP+ (00D9865) 40GBASE-SR4 10 m or 30 m MPO fiber optic cables or MPO-4xLC breakout cables up to 5 m supplied by Lenovo (see Table 3); support for up to 100 m with OM3 or up to 150 m with OM4 multimode fiber optic cable MPO
40Gb eSR4 QSFP+ (00FE325) 40GBASE-SR4 10 m or 30 m MPO fiber optic cables or MPO-4xLC breakout cables up to 5 m supplied by Lenovo (see Table 3); support for up to 300 m with OM3  or up to 400 m with OM4 multimode fiber optic cable MPO
40Gb LR4 QSFP+ (00D6222) 40GBASE-LR4 1310 nm single-mode fiber optic cable up to 10 km LC
Active optical cable 40GBASE-SR4 QSFP+ to QSFP+ active optical cables up to 20 m; QSFP+ to 4x SFP+ active optical break-out cables up to 5 m for 4x 10 GbE SFP+ connections out of a 40 GbE port (see Table 3) QSFP+
Direct attach copper cable 40GBASE-CR4 QSFP+ to QSFP+ DAC cables up to 7 m; QSFP+ to 4x SFP+ DAC break-out cables up to 5 m for 4x 10 GbE SFP+ connections out of a 40 GbE port (see Table 3) QSFP+
10 Gb Ethernet
10Gb SR SFP+ (46C3447)
1/10Gb SFP+ (00MY034)
10GBASE-SR Up to 30 m with fiber optic cables supplied by Lenovo (see Table 3); up to 300 m with OM3 or up to 400 m with OM4 multimode fiber optic cables LC
10Gb LR SFP+
(90Y9412, 00FE331)
10GBASE-LR 1310 nm single-mode fiber optic cable up to 10 km LC
10Gb ER SFP+ (90Y9415) 10GBASE-ER 1310 nm single-mode fiber optic cable up to 40 km LC
10Gb RJ-45 SFP+ (7G17A03130) 10GBASE-T Up to 25 m with UTP Category 6 cables supplied by Lenovo (see Table 3); UTP Category 6a or 7 cables up to 30 m RJ-45
Active optical cable 10GBASE-SR SFP+ active optical cables up to 20 m (see Table 3) SFP+
Direct attach copper cable 10GSFP+Cu SFP+ DAC cables up to 7 m (see Table 3) SFP+
1 Gb Ethernet
1Gb RJ-45 SFP (00FE333) 1000BASE-T Up to 25 m with UTP Category 5E or 6 cables supplied by Lenovo (see Table 3); UTP Category 5, 5E, or 6 up to 100 m RJ-45
1Gb SX SFP (81Y1622)
1/10Gb SFP+ (00MY034)
1000BASE-SX Up to 30 m with fiber optic cables supplied by Lenovo (see Table 3); 850 nm multimode fiber cable 50 µ (OM2) up to 550 m or 62.5 µ (OM1) up to 220 m LC
1Gb LX SFP (90Y9424) 1000BASE-LX 1310 nm single-mode fiber optic cable up to 10 km LC
Management ports
1 GbE management port 1000BASE-T Up to 25 m with UTP Category 5E or 6 cables supplied by Lenovo (see Table 3); UTP Category 5, 5E, or 6 cables up to 100 m RJ-45
Serial port RS-232 DB-9/RJ-45-to-Mini-USB (comes with the switch) Mini-USB

Cloud NOS software features

The RackSwitch G8272 with Cloud NOS has the following software features and specifications:

  • Scalability and performance:
    • Media access control (MAC) address learning with automatic updates
    • Static and LACP (IEEE 802.3ad) link aggregation
    • Broadcast and multicast storm control
    • IGMP snooping to limit flooding of IP multicast traffic
    • IGMP filtering to control multicast traffic for hosts participating in multicast groups
    • Configurable traffic distribution schemes over trunk links based on source or destination IP or MAC addresses, or both
    • Fast port forwarding and fast uplink convergence for rapid STP convergence
  • Availability and redundancy:
    • IEEE 802.1D STP for providing L2 redundancy
    • IEEE 802.1s Multiple STP (MSTP) for topology optimization
    • IEEE 802.1w Rapid STP (RSTP) provides rapid STP convergence for critical delay-sensitive traffic, such as voice or video
    • Per-VLAN Rapid STP (PVRST) enhancements
    • Layer 2 Failover to support active/standby configurations of NIC teaming on servers
  • VLAN support:
    • Up to 4095 VLANs:
      • VLAN 1 is the default VLAN
      • VLAN numbers 2 - 3999 are user-configurable
      • VLAN numbers 4000 - 4095 are reserved for the use by the switch
    • Port-based VLANs
    • Private VLANs
    • 802.1Q VLAN tagging
    • 802.1Q encapsulation on Layer 3 routed ports
    • Ingress VLAN tagging to tunnel packets through a public domain without altering the original 802.1Q tagging information (also known as an Easy Connect or transparent mode)
  • Security:
    • VLAN-based, MAC-based, and IP-based access control lists (ACLs)
    • Multiple user IDs and passwords
    • User access control
    • Radius, TACACS+, and LDAP/LDAPS authentication and authorization
    • Secure mode: Only secure communication protocols are allowed to be enabled
  • Quality of Service (QoS):
    • Support for IEEE 802.1p, IP ToS/DSCP, and ACL-based (MAC/IP source and destination addresses and VLANs) traffic classification and processing
    • Traffic shaping and re-marking that is based on defined policies
    • Eight output Class of Service (COS) queues per port for processing qualified traffic
    • Weighted Random Early Detection (WRED) with Explicit Congestion Notification (ECN) to avoid congestion 
    • Control Plane Protection (CoPP)
    • IPv4 ACL metering
  • IP v4 Layer 3 functions:
    • Host management
    • Routed ports (Switch ports as Layer 3 interfaces)
    • IP forwarding
    • IP filtering with ACLs
    • Virtual Router Redundancy Protocol (VRRP) for router redundancy
    • Static routes
    • Equal Cost Multiple Paths (ECMP)
    • Routing protocols (OSPF v2 and BGP-4)
    • Policy-based routing (PBR)
    • DHCP Relay and DHCP Snooping
    • IGMP snooping
    • DNS client
  • IPv6 Layer 3 functions:
    • IPv6 host management
    • Routed ports (Switch ports as Layer 3 interfaces)
    • IPv6 forwarding
    • Virtual Router Redundancy Protocol (VRRP) for router redundancy
    • Static routes
    • Equal Cost Multiple Paths (ECMP)
    • Routing protocols (BGP-4)
    • DHCP Relay
    • DNS client
  • Virtualization:
    • Virtual link aggregation groups (vLAGs)
      • Two switches (vLAG peers) act as a single virtual entity for a multi-port aggregation
      • vLAG Peer Gateway for improved usage of the link between the vLAG peers
      • Two-tier vLAGs with VRRP enables active/active VRRP to reduce routing latency
    • Data Center Interconnect (DCI) enables bridging of Layer 2 services across multiple locations over existing Layer 3 IP networks by using VXLAN high availability framework.
    • Virtual Routing and Forwarding (VRF) allows multiple instances (up to 64 for data traffic and one for management traffic) of a routing table to coexist and to work simultaneously on the switch to segment network paths.
    • Network Policy Agent gives increased visibility of the virtual infrastructure and automates VM-aware network provisioning and configuration updates for VLANs, virtual NICs, virtual networks, ACLs, and QoS based on the VM associations in a Nutanix (requires the AOS version 5.0.2 or higher [excluding 5.1.2]) or VMware vSphere environment.
    • VXLAN Gateway enables the communication between physical and virtual devices using the VXLAN protocol for VMware NSX integration.
  • Converged Enhanced Ethernet:
    • Priority-Based Flow Control (PFC) (IEEE 802.1Qbb) extends 802.3x flow control to allow the switch to pause traffic that is based on the 802.1p priority value in each packet’s VLAN tag.
    • Enhanced Transmission Selection (ETS) (IEEE 802.1Qaz) provides a method for allocating link bandwidth that is based on the 802.1p priority value in each packet’s VLAN tag.
    • Data Center Bridging Capability Exchange Protocol (DCBX) (IEEE 802.1AB) allows neighboring network devices to exchange information about their capabilities.
  • Monitoring:
    • Switch LEDs for port status and switch status indication
    • Port mirroring for analyzing network traffic passing through switch
    • Change tracking and remote logging with syslog feature
    • Telemetry agent for real-time analytics: Buffer statistics and congestion drop counters
    • sFlow agent for monitoring traffic in data networks (separate sFlow analyzer required elsewhere)
  • Manageability:
    • Industry-standard command line interface (isCLI)
    • Simple Network Management Protocol (SNMP V1, V2, and V3)
    • Telnet interface for CLI
    • Secure Shell (SSH) v1 and v2 for CLI
    • Secure Copy (SCP) for uploading and downloading the configuration file via secure channels
    • Service Location Protocol (SLP)
    • Link Layer Discovery Protocol (LLDP) for discovering network devices
    • Serial interface for CLI
    • Scriptable CLI
    • Dual software images
    • Firmware image update via TFTP, FTP, Secure FTP (sFTP), or USB storage
    • Network Time Protocol (NTP) for switch clock synchronization
    • Lenovo XClarity (optional) for discovery, inventory, monitoring and events
    • Lenovo Intelligent Network Controller (LINC) (optional) for Software-Defined Networking (SDN)
    • Third-party tools integration
      • Lenovo Networking Content Pack for VMware vRealize Log Insight (optional download) for automated log management
      • Integration with Nutanix Prism and VMware vCenter management via Network Policy Agent
      • Lenovo Networking Neutron Plugin to automate VLAN provisioning and configuration updates for OpenStack-based cloud environments
      • Integration with Ansible management
      • Ganglia plug-in for telemetry data analytics

Enterprise NOS software features

The RackSwitch G8272 with ENOS has the following features and specifications:

  • Scalability and performance:
    • Media access control (MAC) address learning with automatic updates
    • Static and LACP (IEEE 802.3ad) link aggregation
    • Broadcast and multicast storm control
    • IGMP snooping to limit flooding of IP multicast traffic
    • IGMP filtering to control multicast traffic for hosts participating in multicast groups
    • Configurable traffic distribution schemes over trunk links based on source or destination IP or MAC addresses, or both
    • Fast port forwarding and fast uplink convergence for rapid STP convergence
  • Availability and redundancy:
    • IEEE 802.1D STP for providing L2 redundancy
    • IEEE 802.1s Multiple STP (MSTP) for topology optimization
    • IEEE 802.1w Rapid STP (RSTP) provides rapid STP convergence for critical delay-sensitive traffic, such as voice or video
    • Per-VLAN Rapid STP (PVRST) enhancements
    • Layer 2 Trunk Failover to support active/standby configurations of NIC teaming on servers
    • Hot Links provides basic link redundancy with fast recovery for network topologies that require Spanning Tree to be turned off
  • VLAN support:
    • Up to 4095 VLANs supported per switch, with VLAN numbers 1 - 4095 (VLAN 4095 is used by the management network.)
    • Port-based and protocol-based VLANs
    • 802.1Q VLAN tagging support
    • Ingress VLAN tagging support to tunnel packets through a public domain without altering the original 802.1Q tagging information
    • Private VLANs support as defined in RFC 5517
  • Security:
    • VLAN-based, MAC-based, and IP-based access control lists (ACLs)
    • 802.1x port-based authentication
    • Multiple user IDs and passwords
    • User access control
    • Radius, TACACS+, and LDAP/LDAPS authentication and authorization
    • NIST 800-131A Encryption
    • Selectable encryption protocol
    • Secure Input/Output Module (SIOM) policy: Secure and Legacy modes
  • Quality of Service (QoS):
    • Support for IEEE 802.1p, IP ToS/DSCP, and ACL-based (MAC/IP source and destination addresses and VLANs) traffic classification and processing
    • Traffic shaping and re-marking that is based on defined policies
    • Eight output Class of Service (COS) queues per port for processing qualified traffic
    • Weighted Random Early Detection (WRED) with Explicit Congestion Notification (ECN) to help avoid congestion
    • IPv4/IPv6 ACL metering
  • IP v4 Layer 3 functions:
    • Host management
    • IP forwarding
    • Network address translation (NAT)
    • IP filtering with ACLs, up to 256 IPv4 ACLs supported
    • Virtual Router Redundancy Protocol (VRRP) for router redundancy
    • Support for up to 128 static routes
    • Equal Cost Multiple Paths (ECMP)
    • Routing protocol support (RIP v1, RIP v2, OSPF v2, and BGP)
    • Support for policy-based routing (PBR)
    • Support for DHCP Relay
    • Support for IGMP snooping and IGMP relay
    • Support for Protocol Independent Multicast (PIM) in Sparse Mode (PIM-SM) and Dense Mode (PIM-DM).
  • IPv6 Layer 3 functions:
    • IPv6 host management
    • IPv6 forwarding
    • Up to 128 static routes
    • Equal Cost Multiple Paths (ECMP)
    • Support for OSPF v3 routing protocol
    • IPv6 filtering with ACLs, up to 128 IPv6 ACLs supported
  • OpenFlow 1.0 and 1.3.1 support
  • Virtualization:
    • Unified Fabric Port (UFP):
      • Up to 8 UFP vPorts per 10 GbE physical port with supported Emulex Virtual Fabric Adapters (VFAs)
      • Up to 4 UFP vPorts per 10 GbE physical port with supported QLogic VFAs
      • Ethernet and storage (NAS, iSCSI, and FCoE) traffic on UFP vPorts (adapter specific)
      • Up to 1024 VLAN for the vPorts
      • VMready or 802.1Qbg Edge Virtual Bridging (not both) on the same physical port
      • Integration with L2 Failover
      • Support for Private VLANs
    • Virtual link aggregation groups (vLAGs)
      • Two switches (vLAG peers) act as a single virtual entity for a multi-port aggregation
      • vLAG Peer Gateway for improved usage of the link between the vLAG peers
      • Two-tier vLAGs with VRRP enables active/active VRRP to reduce routing latency
    • 802.1Qbg Edge Virtual Bridging (EVB) is an IEEE standard for allowing networks to become virtual machine (VM)-aware:
      • Virtual Ethernet Bridging (VEB) and Virtual Ethernet Port Aggregator (VEPA) are mechanisms for switching between VMs on the same hypervisor.
      • Edge Control Protocol (ECP) is a transport protocol that operates between two peers over an IEEE 802 LAN that provides reliable, in-order delivery of upper layer protocol data units.
      • Virtual Station Interface (VSI) Discovery and Configuration Protocol (VDP) allows centralized configuration of network policies that persist with the VM, independent of its location.
      • EVB Type-Length-Value (TLV) is used to discover and configure VEPA, ECP and VDP.
    • VMready support:
      • Up to 4,096 virtual entities (VEs)
      • Automatic VE discovery
      • Up to 4,093 local or distributed VM groups for VEs
      • NMotion® feature for automatic network configuration migration
    • VXLAN Gateway enables the communication between physical and virtual devices using the VXLAN protocol for VMware NSX integration.
  • Converged Enhanced Ethernet:
    • Priority-Based Flow Control (PFC) (IEEE 802.1Qbb) extends 802.3x standard flow control to allow the switch to pause traffic that is based on the 802.1p priority value in each packet’s VLAN tag.
    • Enhanced Transmission Selection (ETS) (IEEE 802.1Qaz) provides a method for allocating link bandwidth that is based on the 802.1p priority value in each packet’s VLAN tag.
    • Data Center Bridging Capability Exchange Protocol (DCBX) (IEEE 802.1AB) allows neighboring network devices to exchange information about their capabilities.
  • FCoE:
    • FC-BB5 FCoE specification compliant
    • FCoE transit switch operations
    • FCoE Initialization Protocol (FIP) support for automatic ACL configuration
    • FCoE Link Aggregation Group (LAG) support
    • Supports 2,048 FCoE sessions with FIP Snooping by using Class ID ACLs
  • Manageability:
    • Industry-standard command line interface (isCLI)
    • Simple Network Management Protocol (SNMP V1, V2, and V3)
    • Telnet interface for CLI
    • Secure Shell (SSH) v1 and v2 for CLI
    • Secure Copy (SCP) for uploading and downloading the configuration file via secure channels
    • Service Location Protocol (SLP)
    • Link Layer Discovery Protocol (LLDP) for discovering network devices
    • Serial interface for CLI
    • Scriptable CLI
    • Dual software images
    • Firmware image update via TFTP, FTP, Secure FTP (sFTP), or USB storage
    • Network Time Protocol (NTP) and Precision Time Protocol (PTP) for switch clock synchronization
    • Netconf (XML)
    • Lenovo XClarity (optional) for discovery, inventory, monitoring and events
    • Lenovo Networking Content Pack for VMware vRealize Log Insight (optional download) for automated log management
  • Monitoring:
    • Switch LEDs for port status and switch status indication
    • Remote Monitoring (RMON) agent to collect statistics and proactively monitor switch performance
    • Port mirroring for analyzing network traffic passing through switch
    • Change tracking and remote logging with syslog feature
    • Support for sFlow agent for monitoring traffic in data networks (separate sFlow analyzer required elsewhere)

The following features are not supported with IPv6:

  • Bootstrap Protocol (BOOTP) and DHCP
  • RADIUS, TACACS+ and LDAP
  • VMware Virtual Center (vCenter) for VMready
  • Routing Information Protocol (RIP)
  • Border Gateway Protocol (BGP)
  • Protocol Independent Multicast (PIM)
  • Virtual Router Redundancy Protocol (VRRP)
  • sFlow

Ethernet standards

The switch supports the following Ethernet standards:

  • IEEE 802.1AB Data Center Bridging Capability Exchange Protocol (DCBX) (ENOS only)
  • IEEE 802.1D Spanning Tree Protocol (STP)
  • IEEE 802.1p Class of Service (CoS) prioritization
  • IEEE 802.1s Multiple STP (MSTP)
  • IEEE 802.1Q Tagged VLAN (frame tagging on all ports when VLANs are enabled)
  • IEEE 802.1Qbg Edge Virtual Bridging (ENOS only)
  • IEEE 802.1Qbb Priority-Based Flow Control (PFC) (ENOS only)
  • IEEE 802.1Qaz Enhanced Transmission Selection (ETS) (ENOS only)
  • IEEE 802.1x port-based authentication (ENOS only)
  • IEEE 802.1w Rapid STP (RSTP)
  • IEEE 802.3 10BASE-T Ethernet
  • IEEE 802.3ab 1000BASE-T copper twisted pair Gigabit Ethernet
  • IEEE 802.3ad Link Aggregation Control Protocol
  • IEEE 802.3ae 10GBASE-SR short range fiber optics 10 Gb Ethernet
  • IEEE 802.3ae 10GBASE-LR long range fiber optics 10 Gb Ethernet
  • IEEE 802.3ae 10GBASE-ER extended range fiber optics 10 Gb Ethernet
  • IEEE 802.3ba 40GBASE-SR4 short range fiber optics 40 Gb Ethernet
  • IEEE 802.3ba 40GBASE-CR4 copper 40 Gb Ethernet
  • IEEE 802.3u 100BASE-TX Fast Ethernet
  • IEEE 802.3x Full-duplex Flow Control
  • IEEE 802.3z 1000BASE-SX short range fiber optics Gigabit Ethernet
  • IEEE 802.3z 1000BASE-LX long range fiber optics Gigabit Ethernet

Cooling

The G8272 switch supports up to four variable speed, hot-swap fan assemblies (four fan assemblies come standard with the switch and they provide 3+1 redundancy). Spare fan assemblies can be ordered, if required (see the following table). Each option contains one hot-swap fan assembly (rear-to front or front-to-rear).

Table 7. Fan assembly spare options
Description Part number Feature code
Rear to front airflow (7159-HCW)
Lenovo RackSwitch Hot-swap, Rear-to-Front Fan Assembly 00FM441 ASRG
Front to rear airflow (7159-HCV)
Lenovo RackSwitch Hot-swap, Front-to-Rear Fan Assembly 00FM440 ASRF

Power supplies and cables

The G8272 switch supports up to two load-sharing, hot-swap 460 W AC Gold power supplies (two power supplies come standard with the switch). Spare power supplies can be ordered, if required (see the following table). Each option contains one hot-swap power supply (rear-to-front or front-to-rear).

Table 8. Power supply spare options
Description Part number Feature code
Rear to front airflow (7159-HCW)
Lenovo RackSwitch Hot-Swap, Rear-to-Front 460W Power Supply 00FM443 ASRJ
Front to rear airflow (7159-HCV)
Lenovo RackSwitch Hot-Swap, Front-to-Rear 460W Power Supply 00FM442 ASRH

The G8272 switch ships standard without any AC power cables. The part numbers and feature codes to order the power cables (two power cables are required per switch) are listed in the following table.

Table 9. AC power cable options
Description Part number Feature code
Rack power cables
1.5m, 10A/100-250V, C13 to IEC 320-C14 Rack Power Cable 39Y7937 6201
1.8m, 10A/100-250V, 2xC13PM to IEC 320-C14 Rack Power Cable None* 6568
2.8m, 10A/100-250V, C13 to IEC 320-C14 Rack Power Cable None* 6311
2.8m, 10A/100-250V, C13 to IEC 320-C20 Rack Power Cable 39Y7938 6204
4.3m, 10A/100-250V, C13 to IEC 320-C14 Rack Power Cable 39Y7932 6263
Line cords
Argentina 10A/250V C13 to IRAM 2073 2.8m line cord 39Y7930 6222
Australia/NZ 10A/250V C13 to AS/NZ 3112 2.8m line cord 39Y7924 6211
Brazil 10A/125V C13 to NBR 6147 2.8m line cord 39Y7929 6223
China 10A/250V C13 to GB 2099.1 2.8m line cord 39Y7928 6210
Denmark 10A/250V C13 to DK2-5a 2.8m line cord 39Y7918 6213
European 10A/230V C13 to CEE7-VII 2.8m line cord 39Y7917 6212
India 10A/250V C13 to IS 6538 2.8m line cord 39Y7927 6269
Israel 10A/250V C13 to SI 32 2.8m line cord 39Y7920 6218
Japan 12A/125V C13 to JIS C-8303 2.8m line cord 46M2593 A1RE
Korea 12A/250V C13 to KETI 2.8m line cord 39Y7925 6219
South Africa 10A/250V C13 to SABS 164 2.8m line cord 39Y7922 6214
Switzerland 10A/250V C13 to SEV 1011-S24507 2.8m line cord 39Y7919 6216
United Kingdom 10A/250V C13 to BS 1363/A 2.8m line cord 39Y7923 6215
United States 10A/125V C13 to NEMA 5-15P 4.3m line cord 39Y7931 6207
United States 10A/250V C13 to NEMA 6-15P 2.8m line cord 46M2592 A1RF

* Available for factory-built custom configurations and solutions only.

Rack installation

The G8272 switch includes a 2-post rack mount kit.

For 4-post rack installations, the G8272 switch supports the optional adjustable 19-inch, 4-post rail kit and the air inlet duct (optional for the 4-post rail kit; supported only with the models with rear to front airflow).

When the G8272 switch (front to rear airflow) is installed in the Intelligent Cluster Rack (Machine Type 1410) or Enterprise Rack (Machine Type 9363) as a part of a NeXtScale System solution, the recessed 19-inch 4-post rail kit is required.

The following table lists rack installation options for the G8272 switches with rear to front and front to rear airflow.

Table 10. Rack installation options
Description Part number Feature code
Rear to front airflow (7159-HCW)
Lenovo RackSwitch Adjustable 19" 4 Post Rail Kit 00D6185 A3KP
Air Inlet Duct for 487 mm RackSwitch 00FM507 ASTN
Front to rear airflow (7159-HCV)
Lenovo RackSwitch Adjustable 19" 4 Post Rail Kit 00D6185 A3KP
Lenovo RackSwitch Recessed 19" 4 Post Rail Kit 00CG089 A51M

Physical specifications

The G8272 switch features the following physical specifications:

  • Height: 44 mm (1.7 in.)
  • Width: 440 mm (17.3 in.)
  • Depth: 487 mm (19.2 in.)
  • Weight: 9.1 kg (20.0 lb)

Operating environment

The G8272 switch is supported in the following operating environment:

  • Temperature: 0 - 40 ºC (32 - 104 ºF).
  • Relative humidity: Non-condensing, 10 - 90%
  • Altitude: Up to 2,000 m (6,561 feet)
  • Acoustic noise: Less than 72 dB
  • Airflow: Front-to-rear or rear-to-front cooling with variable speed fans for reduced power draw
  • Electrical input: 50 - 60 Hz, 100 - 240 V AC auto-switching
  • Electrical power
    • Typical: 123 W
    • Maximum: 240 W
  • Heat dissipation
    • Typical: 420 BTU/hour
    • Maximum: 820 BTU/hour

Warranty and maintenance

The RackSwitch G8272 comes with a limited 3-year hardware warranty with Next Business Day (NBD), 9x5, Customer Replaceable Unit (CRU) warranty service and includes a 3-year software license, which provides entitlement to upgrades over that period. The options that are installed in the switch assume the switch’s base warranty and any Lenovo warranty service upgrade for the switch.

Some regions might have different warranty terms and conditions than the standard warranty. This is due to local business practices or laws in the specific region. Local service teams can assist in explaining region-specific terms when needed. Examples of region-specific warranty terms are second or longer business day parts delivery or parts-only base warranty.

If warranty terms and conditions include onsite labor for repair or replacement of parts, Lenovo will dispatch a service technician to the customer site to perform the replacement. Onsite labor under base warranty is limited to labor for replacement of parts that have been determined to be field-replaceable units (FRUs). Parts that are determined to be customer-replaceable units (CRUs) do not include onsite labor under base warranty.

If warranty terms include parts-only base warranty, Lenovo is responsible for delivering only replacement parts that are under base warranty (including FRUs) that will be sent to a requested location for self-service. Parts-only service does not include a service technician being dispatched onsite. Parts must be changed at customer’s own cost and labor and defective parts must be returned following the instructions supplied with the spares parts.

Also available are Lenovo Services warranty maintenance upgrades and post-warranty maintenance agreements, with a well-defined scope of services, including service hours, response time, term of service, and service agreement terms and conditions.

Lenovo warranty service upgrade offerings are region-specific. Not all warranty service upgrades are available in every region. For information about Lenovo warranty service upgrade offerings that are available in your region, refer to the following resources:

In general, the following Lenovo warranty service upgrades are available:

  • Warranty and maintenance service upgrades:
    • 3, 4, or 5 years of warranty service coverage
    • 1-year or 2-year post-warranty extensions
    • Foundation Service: 9x5 service coverage with next business day onsite response
    • Essential Service: 24x7 service coverage with 4-hour onsite response or 24-hour committed repair (available only in select regions)
    • Advanced Service: 24x7 service coverage with 2-hour onsite response or 6-hour committed repair (available only in select regions)
  • Basic Hardware Installation Services

    Lenovo experts can seamlessly manage the physical installation of your server, storage, or networking hardware. Working at a time convenient for you (business hours or off shift), the technician will unpack and inspect the systems on your site, install options, mount in a rack cabinet, connect to power and network, check and update firmware to the latest levels, verify operation, and dispose of the packaging, allowing your team to focus on other priorities.

For service definitions, region-specific details, and service limitations, please refer to the following documents:

Regulatory compliance

The switch conforms to the following regulations:

  • Safety certifications:
    • UL60950-1
    • CAN/CSA 22.2 No.60950-1
    • TUV/GS to EN 60950-1
    • IEC60950-1, all country deviations
    • CNS 14336-1
    • Argentina Smark to IEC60950-1
    • GB4943.1-2011
    • EAC
    • NOM-019
  • Electromagnetic compatibility certifications:
    • FCC 47CFR Part 15 Class A
    • EN 55022 Class A
    • ICES-003 Class A
    • VCCI Class A
    • AS/NZS CISPR 22 Class A
    • CISPR 22 Class A
    • EN 55024
    • KC Class A
    • CE
  • Environmental: Reduction of Hazardous Substances (ROHS) Directive 2011/65/EU

Network connectivity

The following table lists the network switches with rear-to-front airflow offered by Lenovo that can be used with the RackSwitch G8272 for ThinkSystem and Flex System network connectivity.

Table 11. Network switches (rear-to-front airflow)
Description Part number
1 Gb Ethernet switches
Lenovo ThinkSystem NE0152T RackSwitch (Rear to Front) 7Y810011WW
Lenovo ThinkSystem NE0152TO RackSwitch (Rear to Front, ONIE) 7Z320O11WW
Lenovo RackSwitch G7028 (Rear to Front) 7159BAX
Lenovo RackSwitch G7052 (Rear to Front) 7159CAX
Lenovo RackSwitch G8052 (Rear to Front) 7159G52
10 Gb Ethernet switches
Lenovo ThinkSystem NE1032 RackSwitch (Rear to Front) 7159A1X
Lenovo ThinkSystem NE1032T RackSwitch (Rear to Front) 7159B1X
Lenovo ThinkSystem NE1072T RackSwitch (Rear to Front) 7159C1X
Lenovo RackSwitch G8124E (Rear to Front) 7159BR6
Lenovo RackSwitch G8296 (Rear to Front) 7159GR6
25 Gb Ethernet switches
Lenovo ThinkSystem NE2572 RackSwitch (Rear to Front) 7159E1X
Lenovo ThinkSystem NE2572O RackSwitch (Rear to Front, ONIE) 7Z210O21WW
100 Gb Ethernet switches
Lenovo ThinkSystem NE10032 RackSwitch (Rear to Front) 7159D1X
Lenovo ThinkSystem NE10032O RackSwitch (Rear to Front, ONIE) 7Z210O11WW

The following table lists the network switches with front-to-rear airflow that are offered by Lenovo that can be used with the RackSwitch G8272 for NeXtScale System network connectivity.

Table 12. Network switches (front-to-rear airflow)
Description Part number
1 Gb Ethernet switches
Lenovo RackSwitch G8052 (Front to Rear) 715952F
10 Gb Ethernet switches
Lenovo ThinkSystem NE1032 RackSwitch (Front to Rear) 7159A2X
Lenovo ThinkSystem NE1032T RackSwitch (Front to Rear) 7159B2X
Lenovo ThinkSystem NE1072T RackSwitch (Front to Rear) 7159C2X
Lenovo RackSwitch G8124E (Front to Rear) 7159BF7
Lenovo RackSwitch G8296 (Front to Rear) 7159GF5
25 Gb Ethernet switches
Lenovo ThinkSystem NE2572 RackSwitch (Front to Rear) 7159E2X
100 Gb Ethernet switches
Lenovo ThinkSystem NE10032 RackSwitch (Front to Rear) 7159D2X

For more information, see the list of Product Guides in the Top-of-rack Switches category:
http://lenovopress.com/servers/options/switches

Storage connectivity

The following table lists the external storage systems that are currently offered by Lenovo that can be used with the RackSwitch G8272 for external NAS or iSCSI SAN storage connectivity.

Table 13. External storage systems: DE Series
Description Part number
Worldwide Japan
Lenovo ThinkSystem DE Series Storage (iSCSI connectivity)
Lenovo ThinkSystem DE2000H 10GBASE-T Hybrid Flash Array LFF 7Y70A003WW 7Y701001JP
Lenovo ThinkSystem DE2000H 10GBASE-T Hybrid Flash Array SFF 7Y71A002WW 7Y711005JP
Lenovo ThinkSystem DE2000H iSCSI Hybrid Flash Array LFF 7Y70A004WW 7Y701000JP
Lenovo ThinkSystem DE2000H iSCSI Hybrid Flash Array SFF 7Y71A003WW 7Y711006JP
Lenovo ThinkSystem DE4000H iSCSI Hybrid Flash Array 4U60 7Y77A000WW 7Y771002JP
Lenovo ThinkSystem DE4000H iSCSI Hybrid Flash Array LFF 7Y74A002WW 7Y74A002JP
Lenovo ThinkSystem DE4000H iSCSI Hybrid Flash Array SFF 7Y75A001WW 7Y75A001JP
Lenovo ThinkSystem DE4000F iSCSI All Flash Array SFF 7Y76A002WW 7Y76A002JP
Lenovo ThinkSystem DE6000H iSCSI Hybrid Flash Array 4U60 7Y80A002WW 7Y801000JP
Lenovo ThinkSystem DE6000H iSCSI Hybrid Flash Array SFF 7Y78A002WW 7Y781000JP
Lenovo ThinkSystem DE6000F iSCSI All Flash Array SFF 7Y79A002WW 7Y79A002JP
Table 14. External storage systems: DM Series
Description Part number
Lenovo ThinkSystem DM Series Storage (NAS or iSCSI connectivity)
Lenovo ThinkSystem DM3000H Hybrid Storage Array (2U12 LFF, CTO only) 7Y42CTO1WW
Lenovo ThinkSystem DM3000H 48TB (12x 4TB HDDs) (Universal SFP+) 7Y420001EA*
Lenovo ThinkSystem DM3000H 48TB (12x 4TB HDDs) (10GBASE-T) 7Y420002EA*
Lenovo ThinkSystem DM5000H Hybrid Storage Array (2U24 SFF, CTO only) 7Y57CTO1WW
Lenovo ThinkSystem DM5000H 11.5TB (12x 960GB SSDs) (Universal SFP+) 7Y570001EA*
Lenovo ThinkSystem DM5000H 11.5TB (12x 960GB SSDs) (10GBASE-T) 7Y570002EA*
Lenovo ThinkSystem DM5000H 29TB (24x 1.2TB 10K HDDs) (Universal SFP+) 7Y570003EA*
Lenovo ThinkSystem DM5000H 29TB (24x 1.2TB 10K HDDs) (10GBASE-T) 7Y570004EA*
Lenovo ThinkSystem DM5000F Flash Storage Array (2U24 SFF, CTO only) 7Y41CTO1WW
Lenovo ThinkSystem DM7000H Hybrid Storage Array (3U, CTO only) 7Y56CTO1WW
Lenovo ThinkSystem DM7000F Flash Storage Array (3U, CTO only) 7Y40CTO1WW

* Available only in EMEA.

Table 15. External storage systems: DS Series
Description Part number
Worldwide Japan PRC
Lenovo ThinkSystem DS Series Storage (iSCSI connectivity)
Lenovo ThinkSystem DS2200 LFF FC/iSCSI Dual Controller Unit 4599A31 4599A3J 4599A3C
Lenovo ThinkSystem DS2200 SFF FC/iSCSI Dual Controller Unit 4599A11 4599A1J 4599A1C
Lenovo ThinkSystem DS4200 LFF FC/iSCSI Dual Controller Unit 4617A31 4617A3J 4617A3C
Lenovo ThinkSystem DS4200 SFF FC/iSCSI Dual Controller Unit 4617A11 4617A1J 4617A1C
Lenovo ThinkSystem DS6200 SFF FC/iSCSI Dual Controller Unit 4619A11 4619A1J 4619A1C
DS6200F 12x 400GB 10DWD SSDs, 1x 8Gb FC SFP, 512 Snapshots, Replication 4619A1F 4619J1F 4619C1F
DS6200F 12x 800GB 3DWD SSDs, 1x 8Gb FC SFP, 512 Snapshots, Replication 4619A2F 4619J2F 4619C2F
DS6200F 12x 1.6TB 3DWD SSDs, 1x 8Gb FC SFP, 512 Snapshots, Replication 4619A3F 4619J3F 4619C3F
DS6200F 12x 3.84TB 1DWD SSDs, 1x 8Gb FC SFP, 512 Snapshots, Replication 4619A4F 4619J4F 4619C4F
Table 16. External storage systems: V Series and Storwize for Lenovo
Description Part number
Lenovo Storage V Series (iSCSI connectivity)
Lenovo Storage V3700 V2 LFF Control Enclosure 6535C1D
Lenovo Storage V3700 V2 SFF Control Enclosure 6535C2D
Lenovo Storage V3700 V2 XP LFF Control Enclosure 6535C3D
Lenovo Storage V3700 V2 XP SFF Control Enclosure 6535C4D
Lenovo Storage V5030 LFF Control Enclosure 3Yr S&S 6536C12
Lenovo Storage V5030 LFF Control Enclosure 5Yr S&S 6536C32
Lenovo Storage V5030 SFF Control Enclosure 3Yr S&S 6536C22
Lenovo Storage V5030 SFF Control Enclosure 5Yr S&S 6536C42
Lenovo Storage V5030F SFF Control Enclosure 3Yr S&S 6536B1F
Lenovo Storage V5030F SFF Control Enclosure 5Yr S&S 6536B2F
Lenovo Storage V7000 SFF Control Enclosure 3Yr S&S PRC 6538R11^
Lenovo Storage V7000 SFF Control Enclosure 5Yr S&S PRC 6538R21^
Lenovo Storage V7000F SFF Control Enclosure 3Yr S&S PRC 6538R1G^
Lenovo Storage V7000F SFF Control Enclosure 5Yr S&S PRC 6538R2G^
IBM Storwize for Lenovo (iSCSI connectivity)
IBM Storwize V7000 SFF Control Enclosure, 3YR SWMA 6195C32†
IBM Storwize V7000 SFF Control Enclosure, 3YR SWMA, LA 6195C3L‡
IBM Storwize V7000 SFF Control Enclosure, 5YR SWMA 6195C52†
IBM Storwize V7000 SFF Control Enclosure, 5YR SWMA, LA 6195C5L‡

^ Available only in PRC.
† Available worldwide except Latin America.
‡ Available only in Latin America.

For more information, see the list of Product Guides in the following categories:

Rack cabinets

The following table lists the rack cabinets that are offered by Lenovo that can be used in RackSwitch G8272 solutions.

Table 17. Rack cabinets
Description Part number
25U S2 Standard Rack (1000 mm deep; 2 sidewall compartments) 93072RX
25U Static S2 Standard Rack (1000 mm deep; 2 sidewall compartments) 93072PX
42U S2 Standard Rack (1000 mm deep; 6 sidewall compartments) 93074RX
42U 1100mm Enterprise V2 Dynamic Rack (6 sidewall compartments) 93634PX
42U 1100mm Enterprise V2 Dynamic Expansion Rack (6 sidewall compartments) 93634EX
42U 1200mm Deep Dynamic Rack (6 sidewall compartments) 93604PX
42U 1200mm Deep Static Rack (6 sidewall compartments) 93614PX
42U Enterprise Rack (1105 mm deep; 4 sidewall compartments) 93084PX
42U Enterprise Expansion Rack (1105 mm deep; 4 sidewall compartments) 93084EX

For more information, see the list of Product Guides in the Rack cabinets category:
http://lenovopress.com/servers/options/racks

Power distribution units

The following table lists the power distribution units (PDUs) that are offered by Lenovo that can be used in RackSwitch G8272 solutions.

Table 18. Power distribution units
Description Part number
0U Basic PDUs
0U 36 C13/6 C19 24A/200-240V 1 Phase PDU with NEMA L6-30P line cord 00YJ776
0U 36 C13/6 C19 32A/200-240V 1 Phase PDU with IEC60309 332P6 line cord 00YJ777
0U 21 C13/12 C19 32A/200-240V/346-415V 3 Phase PDU with IEC60309 532P6 line cord 00YJ778
0U 21 C13/12 C19 48A/200-240V 3 Phase PDU with IEC60309 460P9 line cord 00YJ779
Switched and Monitored PDUs
0U 20 C13/4 C19 Switched and Monitored 24A/200-240V/1Ph PDU w/ NEMA L6-30P line cord 00YJ781
0U 20 C13/4 C19 Switched and Monitored 32A/200-240V/1Ph PDU w/ IEC60309 332P6 line cord 00YJ780
0U 18 C13/6 C19 Switched / Monitored 32A/200-240V/346-415V/3Ph PDU w/ IEC60309 532P6 cord 00YJ782
0U 12 C13/12 C19 Switched and Monitored 48A/200-240V/3Ph PDU w/ IEC60309 460P9 line cord 00YJ783
1U 9 C19/3 C13 Switched and Monitored DPI PDU (without line cord) 46M4002
1U 9 C19/3 C13 Switched and Monitored 60A 3Ph PDU with IEC 309 3P+Gnd cord 46M4003
1U 12 C13 Switched and Monitored DPI PDU (without line cord) 46M4004
1U 12 C13 Switched and Monitored 60A 3 Phase PDU with IEC 309 3P+Gnd line cord 46M4005
Ultra Density Enterprise PDUs (9x IEC 320 C13 + 3x IEC 320 C19 outlets)
Ultra Density Enterprise C19/C13 PDU Module (without line cord) 71762NX
Ultra Density Enterprise C19/C13 PDU 60A/208V/3ph with IEC 309 3P+Gnd line cord 71763NU
C13 Enterprise PDUs (12x IEC 320 C13 outlets)
DPI C13 Enterprise PDU+ (without line cord) 39M2816
DPI Single Phase C13 Enterprise PDU (without line cord) 39Y8941
C19 Enterprise PDUs (6x IEC 320 C19 outlets)
DPI Single Phase C19 Enterprise PDU (without line cord) 39Y8948
DPI 60A 3 Phase C19 Enterprise PDU with IEC 309 3P+G (208 V) fixed line cord 39Y8923
Front-end PDUs (3x IEC 320 C19 outlets)
DPI 30amp/125V Front-end PDU with NEMA L5-30P line cord 39Y8938
DPI 30amp/250V Front-end PDU with NEMA L6-30P line cord 39Y8939
DPI 32amp/250V Front-end PDU with IEC 309 2P+Gnd line cord 39Y8934
DPI 60amp/250V Front-end PDU with IEC 309 2P+Gnd line cord 39Y8940
DPI 63amp/250V Front-end PDU with IEC 309 2P+Gnd line cord 39Y8935
Universal PDUs (7x IEC 320 C13 outlets)
DPI Universal 7 C13 PDU (with 2 m IEC 320-C19 to C20 rack power cord) 00YE443
NEMA PDUs (6x NEMA 5-15R outlets)
DPI 100-127V PDU with fixed NEMA L5-15P line cord 39Y8905
Line cords for PDUs that ship without a line cord
DPI 30a Line Cord (NEMA L6-30P) 40K9614
DPI 32a Line Cord (IEC 309 P+N+G) 40K9612
DPI 32a Line Cord (IEC 309 3P+N+G) 40K9611
DPI 60a Cord (IEC 309 2P+G) 40K9615
DPI 63a Cord (IEC 309 P+N+G) 40K9613
DPI Australian/NZ 3112 Line Cord (32A) 40K9617
DPI Korean 8305 Line Cord (30A) 40K9618

For more information, see the list of Product Guides in the Power Distribution Units category:
http://lenovopress.com/servers/options/pdu

Uninterruptible power supply units

The following table lists the uninterruptible power supply (UPS) units that are offered by Lenovo that can be used in RackSwitch G8272 solutions.

Table 19. Uninterruptible power supply units
Description Part number
Worldwide models
RT1.5kVA 2U Rack or Tower UPS (100-125VAC) (8x NEMA 5-15R 12A outlets) 55941AX
RT1.5kVA 2U Rack or Tower UPS (200-240VAC) (8x IEC 320 C13 10A outlets) 55941KX
RT2.2kVA 2U Rack or Tower UPS (100-125VAC) (8x NEMA 5-20R 16A outlets) 55942AX
RT2.2kVA 2U Rack or Tower UPS (200-240VAC) (8x IEC 320 C13 10A, 1x IEC 320 C19 16A outlets) 55942KX
RT3kVA 2U Rack or Tower UPS (100-125VAC) (6x NEMA 5-20R 16A, 1x NEMA L5-30R 24A outlets) 55943AX
RT3kVA 2U Rack or Tower UPS (200-240VAC) (8x IEC 320 C13 10A, 1x IEC 320 C19 16A outlets) 55943KX
RT5kVA 3U Rack or Tower UPS (200-240VAC) (8x IEC 320 C13 10A, 2x IEC 320 C19 16A outlets) 55945KX
RT6kVA 3U Rack or Tower UPS (200-240VAC) (8x IEC 320 C13 10A, 2x IEC 320 C19 16A outlets) 55946KX
RT8kVA 6U Rack or Tower UPS (200-240VAC) (4x IEC 320-C19 16A outlets) 55948KX
RT11kVA 6U Rack or Tower UPS (200-240VAC) (4x IEC 320-C19 16A outlets) 55949KX
RT8kVA 6U 3:1 Phase Rack or Tower UPS (380-415VAC) (4x IEC 320-C19 16A outlets) 55948PX
RT11kVA 6U 3:1 Phase Rack or Tower UPS (380-415VAC) (4x IEC 320-C19 16A outlets) 55949PX
ASEAN, HTK, INDIA, and PRC models
ThinkSystem RT3kVA 2U Standard UPS (200-230VAC) (2x C13 10A, 2x GB 10A, 1x C19 16A outlets) 55943KT
ThinkSystem RT3kVA 2U Long Backup UPS (200-230VAC) (2x C13 10A, 2x GB 10A, 1x C19 16A outlets) 55943LT
ThinkSystem RT6kVA 5U UPS (200-230VAC) (2x C13 10A outlets, 1x Terminal Block output) 55946KT
ThinkSystem RT10kVA 5U UPS (200-230VAC) (2x C13 10A outlets, 1x Terminal Block output) 5594XKT

For more information, see the list of Product Guides in the Uninterruptible Power Supply Units category:
http://lenovopress.com/servers/options/ups#rt=product-guide

Lenovo Financial Services

Lenovo Financial Services reinforces Lenovo’s commitment to deliver pioneering products and services that are recognized for their quality, excellence, and trustworthiness. Lenovo Financial Services offers financing solutions and services that complement your technology solution anywhere in the world.

We are dedicated to delivering a positive finance experience for customers like you who want to maximize your purchase power by obtaining the technology you need today, protect against technology obsolescence, and preserve your capital for other uses.

We work with businesses, non-profit organizations, governments and educational institutions to finance their entire technology solution. We focus on making it easy to do business with us. Our highly experienced team of finance professionals operates in a work culture that emphasizes the importance of providing outstanding customer service. Our systems, processes and flexible policies support our goal of providing customers with a positive experience.

We finance your entire solution. Unlike others, we allow you to bundle everything you need from hardware and software to service contracts, installation costs, training fees, and sales tax. If you decide weeks or months later to add to your solution, we can consolidate everything into a single invoice.

Our Premier Client services provide large accounts with special handling services to ensure these complex transactions are serviced properly. As a premier client, you have a dedicated finance specialist who manages your account through its life, from first invoice through asset return or purchase. This specialist develops an in-depth understanding of your invoice and payment requirements. For you, this dedication provides a high-quality, easy, and positive financing experience.

For your region specific offers please ask your Lenovo sales representative or your technology provider about the use of Lenovo Financial Services. For more information, see the following Lenovo website:
http://www.lenovofs.com

Related product families

Product families related to this document are the following:

Trademarks

Lenovo and the Lenovo logo are trademarks or registered trademarks of Lenovo in the United States, other countries, or both. A current list of Lenovo trademarks is available on the Web at https://www.lenovo.com/us/en/legal/copytrade/.

The following terms are trademarks of Lenovo in the United States, other countries, or both:
Lenovo®
Flex System
Intelligent Cluster
Lenovo Services
NMotion®
NeXtScale
NeXtScale System®
RackSwitch
ThinkAgile®
ThinkSystem®
VMready®
XClarity®

The following terms are trademarks of other companies:

Linux® is the trademark of Linus Torvalds in the U.S. and other countries.

Other company, product, or service names may be trademarks or service marks of others.