Abstract
The Lenovo® Storage S3200 (shown in the following figure) is a versatile storage system that is designed to provide simplicity, speed, scalability, security, and high availability for small to large businesses. The S3200 SAN array delivers enterprise-class storage management technology in a cost-effective solution with a wide choice of host connectivity options, flexible drive configurations, and enhanced data management features.
The S3200 is a perfect fit for businesses of all sizes, from small to enterprise, that need a primary feature-rich storage solution. The S3200 supports multiple storage connectivity protocols and is designed for a wide range of workloads, from specialized workloads such as big data and analytics, video surveillance, media streaming, and private clouds to general purpose workloads such as file and print serving, web serving, e-mail and collaboration, and OLTP databases. The S3200 is also suited very well for secure archive storage or a consolidated backup solution.
Product availability:
- This Product Guide describes withdrawn models of the Lenovo Storage S3200 that are no longer available for ordering.
- For currently available models of the Lenovo SAN Storage Arrays, refer to:
http://lenovopress.com/storage/san/lenovo#rt=product-guide
Watch the walk-through video with Ilya Krutov and Narayan Kumar
Introduction
The Lenovo® Storage S3200 (shown in the following figure) is a versatile storage system that is designed to provide simplicity, speed, scalability, security, and high availability for small to large businesses. The S3200 SAN array delivers enterprise-class storage management technology in a cost-effective solution with a wide choice of host connectivity options, flexible drive configurations, and enhanced data management features.
The S3200 is a perfect fit for for a wide range of workloads, from specialized workloads such as big data and analytics, video surveillance, media streaming, and private clouds to general purpose workloads such as file and print serving, web serving, e-mail and collaboration, and OLTP databases. The S3200 is also suited very well for secure archive storage or a consolidated backup solution.
Figure 1. Lenovo Storage S3200
The S3200 offers the flexible choice of storage connectivity protocols: 6/12 Gb SAS, 1 Gb or 10 Gb iSCSI, and 4/8/16 Gb Fibre Channel (FC). Converged Network Controller (CNC) design of the S3200 makes the selection of iSCSI or FC host connectivity (or both FC and iSCSI) as simple as attaching corresponding transceivers or 10 GbE SFP+ Direct-Attach Copper (DAC) cables to the SFP/SFP+ ports on the RAID controller.
The S3200 supports up to 192 drives with up to seven external expansion enclosures, and it offers flexible drive configurations with the choice of 2.5-inch and 3.5-inch drive form factors, 10K or 15K rpm SAS and 7.2K rpm NL SAS hard disk drives (HDDs) and self-encrypting drives (SEDs), and SAS solid-state drives (SSDs). The S3200 can be scaled up to 960 TB of raw storage capacity.
Did you know?
The S3200 supports Intelligent Real-time Tiering capabilities that help optimize system performance, reduce costs, and simplify management. The base software includes the ability to move data dynamically between SAS HDDs that are optimized for cost per IOPS and NL SAS HDDs that are optimized for cost per GB. With the optional software license, the S3200 supports hybrid tiering across HDDs and SSDs.
With flexibility of the Converged Network Controllers, the S3200 supports hybrid iSCSI and Fibre Channel connectivity at the same time.
The S3200 supports battery-free cache protection which reduces maintenance costs and provides permanent backup of unwritten cache data in case of power failure.
Key features
Key features and benefits provided by the S3200 storage system include:
- Versatile, scalable storage with a single controller, or dual active/active controller configurations for high availability and performance.
- Flexible host connectivity to match diverse client needs with support for 6/12 Gb SAS (SAS controller) or 1/10 Gb iSCSI or 4/8/16 Gb FC connectivity (FC and iSCSI controller) or both iSCSI and FC at the same time.
- 6 Gb SAS drive-side connectivity with support for 12x 3.5-inch large form factor (LFF) or 24x 2.5-inch small form factor (SFF) drives in the controller enclosure; scalable up to 96 LFF drives per system with the attachment of Lenovo Storage E1012 expansion enclosure (12x LFF drives each) or up to 192 SFF drives per system with the attachment of Lenovo Storage E1024 expansion enclosure (24x SFF drives each) to satisfy growing needs for storage capacity and performance.
- Flexibility in storing data on high performance SAS SSDs, performance-optimized enterprise SAS HDDs, or capacity-optimized enterprise NL SAS HDDs; mixing and matching drive types and form factors within a single system to perfectly meet performance and capacity requirements for various workloads.
- Support for self-encrypting drives to allow clients to secure their sensitive data and to comply with various security regulations when required.
- Rich set of standard functions available at no additional cost, including virtualized storage pools, snapshots, thin provisioning, rapid rebuild, real-time HDD tiering, and SSD read cache.
- Optional licensed functions, including higher number of snapshots for more scalability, real-time SSD tiering for boosting IOPS performance, and asynchronous replication for 24x7 data protection and disaster recovery.
- Intuitive, web-based GUI for easy system setup and management.
- Designed to comply with NEBS and MIL-STD requirements.
- Designed for 99.999% availability.
The S3200 is designed to support the complete range of data storage requirements, from highly utilized applications to high-capacity, low usage applications.
The following 3.5-inch drives are supported:
- High performance solid-state drives (10 drive writes per day [DWD]): 400 GB
- Performance-optimized, enterprise class disk drives: 600 GB and 900 GB 10K rpm
- High-capacity, archival-class nearline disk drives: 2 TB, 4 TB, 6 TB, 8 TB, and 10 TB 7.2K rpm
The following 2.5-inch drives are supported:
- High performance solid-state drives (3 DWD and 10 DWD): 400 GB, 800 GB, and 1.6 TB
- High performance self-encrypting solid-state drives (10 DWD): 400 GB and 800 GB
- Capacity-optimized solid-state drives (1 DWD): 3.84 TB
- Performance-optimized, enterprise class disk drives
- 300 GB and 600 GB 15K rpm
- 600 GB, 900 GB, 1.2 TB, and 1.8 TB 10K rpm
- High-capacity, archival-class nearline disk drives: 1 TB and 2 TB 7.2K rpm
Additional drives and expansion units are designed to be dynamically added with virtually no downtime, helping to quickly and seamlessly respond to ever-growing capacity demands.
The S3200 storage system is designed to offer high levels of system and data availability with the following technologies:
- Dual-active RAID controllers with low latency cache mirroring
- Dual-port drives (both HDDs and SSDs) with automatic drive failure detection and rapid RAID rebuild with global hot spares
- Redundant hardware, including host ports, controller modules, and power supplies and fans
- Hot-swappable and customer replaceable components, including controllers, power supplies with fans, and drives
- Automated path failover support for the data path between the host and the drives with multipathing software
- Non-disruptive controller firmware upgrades for dual controller configurations with multipathing
The following functions are included with every S3200:
- Intelligent Real-time Tiering for HDDs: Storage tiering helps optimize storage use with intelligent data placement to improve system performance, reduce costs, and simplify management. The S3200 automatically and dynamically moves frequently accessed data to higher performing HDDs in the system without manually creating and managing storage tier policies.
- RAID levels 1, 5, 6, and 10: Provide the flexibility to choose the level of data protection required.
- Virtualized storage pools: Enables rapid, flexible storage provisioning and simple configuration changes. Stored data is distributed across all drive groups in the pool (wide striping) which helps improve performance, lower latency, and achieve higher volume capacities. When a new drive group is added to the pool, the system performs automatic rebalancing to utilize all drives in the pool for better performance.
- Thin provisioning: Optimizes efficiency by allocating drive storage space in a flexible manner among multiple applications, based on the minimum space required by each application at any given time. With thin provisioning, applications consume only the space they are actually using, not the total space that has been allocated to them, which allows clients to purchase storage they need today and add more as application requirements grow.
- SSD Read Cache: An extension of the controller's cache to improve performance of read-centric workloads
- Rapid RAID Rebuild: Helps significantly decrease the time to recover lost data by only rebuilding the stripe where the corruption occurred, not the empty space or other stripes
- Snapshots: Enables creation of copies of data for backup, parallel processing, testing, and development, and have the copies available almost immediately. Base software supports up to 128 snapshot targets per system.
The S3200 storage capabilities can be expanded with optional licensed functions. Each optional S3200 function is licensed on a per-system basis and covers both controller enclosure and all attached expansion units.
Optional licensed functions include:
- Intelligent Real-time Tiering for SSDs: The SSD tiering upgrade option allows the use of SSDs as read and write storage in the hybrid HDD and SSD storage configurations. Also, this option makes it easy and economical to deploy hybrid storage by dynamically moving frequently accessed data to SSDs in the system, resulting in flash drive performance without manually creating and managing storage tier policies.
- Snapshots upgrade: The snapshot upgrade options increase the supported number of snapshot targets to 512 or 1,024 per system.
-
Asynchronous Replication: The asynchronous replication feature provides storage system-based data replication between two peers by using asynchronous data transfers over IP communication links.
The replication is done at predetermined intervals (Now, 1 hour, 12 hour, 24 hour) and does not require high-bandwidth network connection. For ultimate flexibility, S3200 asynchronous replication interoperates with Lenovo Storage S2200 and ThinkSystem DS Series.
The asynchronous replication option must be acquired (or licensed) for both primary (local) and secondary (remote) systems.
The S3200 supports the following management interfaces:
- Web-based graphical user interface (GUI) via HTTP that requires only a supported browser (Microsoft Internet Explorer, Google Chrome, or Mozilla Firefox), so there is no need for a separate console or plug-in
- Command line interface (CLI) via Telnet or SSH or through Direct Connect USB
- HTTP scripting interface with XML encoding
- SNMP and e-mail notifications
Components and connectors
The following figure shows the front of the S3200 SFF chassis and E1024 drive expansion enclosure.
Figure 2. Front view of the S3200 SFF chassis and E1024 drive enclosure
The following figure shows the front of the S3200 LFF chassis and E1012 drive expansion enclosure.
Figure 3. Front view of the S3200 LFF chassis and E1012 drive enclosure
The following figure shows the rear of the S3200 with FC or iSCSI host interfaces with dual RAID controllers. Single RAID controller configurations are also supported.
Figure 4. Rear view of the S3200 with FC or iSCSI host interfaces
The following figure shows the rear of the S3200 with SAS host interfaces with dual RAID controllers. Single RAID controller configurations are also supported.
Figure 5. Rear view of the S3200 with SAS host interfaces
The following figure shows the rear of the E1012 and E1024 drive enclosures with dual I/O expansion modules. Single I/O module configurations are also supported with the single-controller S3200.
Figure 6. Rear view of the E1012 and E1024 drive enclosures
Note: The RAID controllers (shown in Figure 4 and Figure 5) and expansion modules (shown in Figure 6) have additional service ports with a specialized connector, and these ports are reserved for use by a Lenovo service technician.
System specifications
The following table lists the S3200 storage system technical specifications.
Components | Specification |
Form factor | S3200 controller enclosure: 2U rack mount E1012 or E1024 drive expansion enclosure: 2U rack mount |
RAID controller configuration | Two types of controllers:
|
RAID levels | RAID 1, 5, 6, and 10 |
RAID controller cache | 6 GB per controller. Battery-free cache protection with flash memory and supercapacitors. Low latency cache mirroring protection for dual controller configurations. |
Drive bays | Up to 192 SFF drive bays per system:
|
Drive technologies | SAS and NL SAS HDDs and SEDs; eMLC SAS SSDs. Intermix of HDDs and SSDs is supported. Intermix of SEDs with HDDs or SSDs is not supported. |
Drive connectivity |
Dual-ported 6 Gb SAS drive attachment infrastructure. Controller enclosure with one or two RAID controllers (ports per one controller):
|
Drives | SFF drives:
|
Storage capacity | Up to 960 TB (96x 10 TB NL SAS HDDs) |
Host connectivity | S3200 SAS controller: 4x 6/12 Gb SAS host ports (Mini-SAS HD, SFF-8644) S3200 FC and iSCSI controller: 4x SFP/SFP+ host ports with two built-in dual-port CNCs (each port on the same CNC must have the same connectivity type, different CNCs might have different connectivity types) CNC host port options (per each CNC on the RAID controller):
|
Host operating systems | Microsoft Windows Server 2012 R2 and 2016; Red Hat Enterprise Linux (RHEL) 6 and 7; SUSE Linux Enterprise Server (SLES) 11 and 12; VMware vSphere 5.5, 6.0, and 6.5. |
Standard software features | Intelligent Real-time Tiering for HDDs, Virtualized Storage Pools, Thin Provisioning, SSD Read Cache, Rapid RAID Rebuild, Snapshots - up to 128 targets. |
Optional software features | Intelligent Real-time Tiering for SSDs, Snapshots - up to 1,024 targets, Asynchronous Replication. |
Performance | Dual controller configuration:
|
Configuration maximums | Per system:
|
Cooling | Redundant cooling with two fans that are built into power supplies. |
Power supply | Two redundant hot-swap 595 W AC power supplies. |
Hot-swap parts | RAID controllers, expansion modules, SFP/SFP+ transceivers, drives, power supplies/fans. |
Management interfaces | Web-based graphical user interface (GUI); Telnet, SSH, or Direct Connect USB command-line interface (CLI); HTTP scripting with XML encoding; SNMP and e-mail notifications |
Security features | Secure Socket Layer (SSL), Secure Shell (SSH), self-encrypting drives (SEDs) |
Warranty | Three-year customer-replaceable unit, parts only limited warranty with 9x5 next business day. |
Service and support | Optional warranty service upgrades are available through Lenovo: on-site support, 24x7 coverage, 4-hour response time, 1-year or 2-year warranty extensions, Hard Drive Retention. |
Dimensions |
|
Weight |
|
Controller enclosures
The following table lists the relationship models of the S3200.
Product availability: Relationship and TopSeller models of the Lenovo Storage S3200 are withdrawn and no longer available for ordering. For currently available models of the Lenovo SAN Storage Arrays, refer to:
http://lenovopress.com/storage/san/lenovo#rt=product-guide
Description | Part number |
LFF models | |
Lenovo Storage S3200 LFF Chassis SAS Single Controller, Rack Kit, 9x5NBD | 64113B1* |
Lenovo Storage S3200 LFF Chassis SAS Dual Controller, Rack Kit, 9x5NBD | 64113B2 |
Lenovo Storage S3200 LFF Chassis FC/iSCSI Single Controller, Rack Kit, 9x5NBD | 64116B1* |
Lenovo Storage S3200 LFF Chassis FC/iSCSI Dual Controller, Rack Kit, 9x5NBD | 64116B2 |
SFF models | |
Lenovo Storage S3200 SFF Chassis SAS Single Controller, Rack Kit, 9x5NBD | 64113B3* |
Lenovo Storage S3200 SFF Chassis SAS Dual Controller, Rack Kit, 9x5NBD | 64113B4 |
Lenovo Storage S3200 SFF Chassis FC/iSCSI Single Controller, Rack Kit, 9x5NBD | 64116B3* |
Lenovo Storage S3200 SFF Chassis FC/iSCSI Dual Controller, Rack Kit, 9x5NBD | 64116B4 |
* Not available for ordering in North America (United States and Canada).
The part number for the S3200 includes the following items:
- One S3200 chassis with two power supplies and fans:
- With one or two SAS RAID controllers installed
- With one or two FC and iSCSI RAID controllers installed
- Two 4.3 m, 10 A/100 - 250 V, C13 to IEC 320-C14 Rack Power Cables
- Lenovo Storage SAN Rack Mount Kit: Rails 25-inch to 36-inch
- Lenovo 1.5 m USB console cable (USB to-Mini-USB)
- Getting Started Guide
- Warranty Flyer
- Important Notices Flyer
- Documentation Flyer
The following table lists the TopSeller models of the S3200.
Description | Part number |
LFF models | |
S3200 LFF Dual FC/iSCSI Controller/4x 8Gb FC/Rack Kit/Base Warranty | 6411E24* |
SFF models | |
S3200 SFF Dual SAS Controller/4x 400GB SSDs/10x 600GB 10K HDDs/Rack Kit/Base Warranty | 6411E25* |
S3200 SFF Dual FC/iSCSI Controller/4x 8Gb FC/Rack Kit/Base Warranty | 6411E29* |
S3200 SFF Dual FC/iSCSI Controller/4x 8Gb FC/Rack Kit/Base Warranty | 6411E37* |
S3200 SFF Dual FC/iSCSI Controller/4x 8Gb FC/5x 300GB 15K HDDs/Rack Kit/Base Warranty | 6411E26* |
S3200 SFF Dual FC/iSCSI Controller/4x 8Gb FC/5x 600GB 10K HDDs/Rack Kit/Base Warranty | 6411E27* |
S3200 SFF Dual FC/iSCSI Controller/2x 8Gb FC/5x 900GB 10K HDDs/Rack Kit/Base Warranty | 6411E28* |
S3200 SFF Dual FC/iSCSI Controller/4x 8Gb FC/6x 600GB 10K HDDs/Rack Kit/Base Warranty | 6411E36* |
S3200 SFF Dual FC/iSCSI Controller/4x 8Gb FC/8x 600GB 10K HDDs/Rack Kit/Base Warranty | 6411E33* |
S3200 SFF Dual FC/iSCSI Controller/4x 8Gb FC/8x 900GB 10K HDDs/Rack Kit/Base Warranty | 6411E31* |
S3200 SFF Dual FC/iSCSI Controller/4x 8Gb FC/8x 900GB 10K HDDs/4x 400GB SSDs/Tiering | 6411E2D |
S3200 SFF Dual FC/iSCSI Controller/4x 16Gb FC/12x 600GB 10K HDDs/Rack Kit/Base Warranty | 6411E35* |
S3200 SFF Dual FC/iSCSI Controller/4x 16Gb FC/10x 600GB 10K HDDs/4x 400GB SSDs/Tiering | 6411E34 |
* Not available for ordering in North America (United States and Canada).
Note: S3200 TopSeller models are country-specific; that is, not all listed models might be available for ordering in a particular country or area. Ask a Lenovo representative for specifics.
The S3200 TopSeller model part numbers include the following items:
- One S3200 chassis with two power supplies and fans:
- With two SAS RAID controllers installed
- With two FC/iSCSI RAID controllers installed (with 2x or 4x SFPs; see Table 3 for details)
- Without drives, or with HDDs, or with HDDs and SSDs (see Table 3 for details)
- Tiering license (part numbers 6411E2D and 6411E34 only)
- Two 4.3 m, 10 A/100 - 250 V, C13 to IEC 320-C14 Rack Power Cables
- Lenovo Storage SAN Rack Mount Kit: Rails 25-inch to 36-inch
- Lenovo 1.5 m USB console cable (USB to Mini-USB)
- Getting Started Guide
- Warranty Flyer
- Important Notices Flyer
- Documentation Flyer
RAID controller modules
The S3200 supports single and dual controller configurations. Standard models of the S3200 ship with two RAID controller modules (see Table 2). Custom models of the S3200 can be configured with one or two RAID controllers. Single-controller models can be upgraded to dual-controller models non-disruptively.
There are two types of RAID controller modules available:
- S3200 SAS RAID Controllers
- S3200 FC and iSCSI RAID Controllers
S3200 SAS RAID Controllers provide direct SAS attachment for up to four hosts with a supported SAS HBA installed in the host. Each S3200 SAS Controller has four 6/12 Gb SAS ports with Mini-SAS HD (SFF-8644) connectors.
S3200 FC and iSCSI RAID Controllers provide SAN based iSCSI or Fibre Channel connectivity to the hosts with a supported software initiator or HBA installed. Each S3200 FC and iSCSI Controller has two built-in CNCs that have two SFP/SFP+ ports each for a total of four SFP/SFP+ ports per RAID controller. Ports on the CNC must have the same connectivity type, and different CNCs might have different connectivity types.
The Converged Network Controller supports the following storage connectivity protocols depending on the SFP/SFP+ transceivers installed:
- 1 Gb iSCSI with 1 GbE RJ-45 SFP optical modules
- 1/10 Gb iSCSI with 10 GbE SW SFP+ optical modules with LC connectors
- 10 Gb iSCSI with 10 GbE SFP+ DAC cables
- 4/8 Gb Fibre Channel with 8 Gb FC SW SFP+ optical modules with LC connectors
- 4/8/16 Gb Gb Fibre Channel with 16 Gb FC SW SFP+ optical modules with LC connectors
Notes:
- Both ports on the same CNC on the S3200 FC and iSCSI RAID Controller must have the same connectivity type (the same type of SFP/SFP+ modules or DAC cables).
- Hybrid iSCSI and FC connectivity or 1 Gb and 10 Gb iSCSI connectivity is supported on a per CNC basis; that is, each of two CNCs on the RAID controller is configured with the different types of transceivers.
- For dual-controller configurations, both RAID controllers in the system must be of the same type, and they must have matching port configurations (i.e. the matching ports on both RAID controllers must have SFP/SFP+ modules of the same type).
Both SAS controllers and FC and iSCSI controllers have one 6 Gb SAS x4 expansion port (Mini-SAS SFF-8088 connector) for the attachment of the E1012 and E1024 expansion enclosures.
The following table lists ordering information for the RAID controllers and related connectivity options.
Description | Part number | Feature code (MTM 6411-HC2) | Max qty per one S3200 |
RAID controller modules | |||
Lenovo Storage S3200 FC and iSCSI Controller | 00WC083 | AT23 | 2 |
Lenovo Storage S3200 SAS Controller | 00WC084 | AT24 | 2 |
FC and iSCSI controller host connectivity options | |||
Lenovo Storage S2200/S3200 1G RJ45 iSCSI SFP+ Module 1 pack | 00WC086 | AT2C | 8* |
Lenovo Storage S2200/S3200 10G SW Optical iSCSI SFP+ Module 1 pack | 00WC087 | AT2A | 8* |
Lenovo Storage S2200/S3200 8G Fibre Channel SFP+ Module 1 pack | 00WC088 | AT28 | 8* |
Lenovo Storage S2200/S3200 16G Fibre Channel SFP+ Module 1 pack | 00WC089 | AT29 | 8* |
Cable options for FC and optical iSCSI host connectivity options | |||
Lenovo 1m LC-LC OM3 MMF Cable | 00MN502 | ASR6 | 8** |
Lenovo 3m LC-LC OM3 MMF Cable | 00MN505 | ASR7 | 8** |
Lenovo 5m LC-LC OM3 MMF Cable | 00MN508 | ASR8 | 8** |
Lenovo 10m LC-LC OM3 MMF Cable | 00MN511 | ASR9 | 8** |
Lenovo 25m LC-LC OM3 MMF Cable | 00MN517 | ASRB | 8** |
DAC cable options for 10 Gb iSCSI host connectivity | |||
Lenovo 1m Passive SFP+ DAC Cable | 90Y9427 | A1PH | 8** |
Lenovo 2m Passive SFP+ DAC Cable | 00AY765 | A51P | 8** |
Lenovo 3m Passive SFP+ DAC Cable | 90Y9430 | A1PJ | 8** |
SAS host connectivity cables - Mini-SAS HD (controller) to Mini-SAS (host) | |||
1.5m HD-miniSAS to miniSAS SAS Cable | 00D5224 | A3HX | 8** |
3m HD-miniSAS to miniSAS SAS Cable | 00D5226 | A3HY | 8** |
SAS host connectivity cables - Mini-SAS HD (controller) to Mini-SAS HD (host) | |||
External MiniSAS HD 8644/MiniSAS HD 8644 1m cable | 00WE748 | AT1D | 8** |
External MiniSAS HD 8644/MiniSAS HD 8644 2m cable | 00WE749 | AT1E | 8** |
Cable options for 1 Gb iSCSI and management ports | |||
Lenovo Ethernet CAT5E shielded 6m cable | 00WE747 | AT1G | 10*** |
Spare cables for serial management ports | |||
Lenovo USB A Male-to-Mini-B 1.5m cable | 00WE746 | AT1F | 1 |
* Up to two SFP/SFP+ modules per CNC, up to four modules per controller. Mixing module types is supported on different CNCs; ports on the same CNC must have the same connectivity type.
** Up to two cables per CNC, up to four cables per controller.
*** Up to two cables per CNC with 1G RJ45 modules attached, up to five cables per controller (one cable for 1 GbE management port connection; up to four cables for CNC port connections with RJ-45 SFP+ modules installed).
Expansion enclosures
The S3200 supports attachment of up to seven Lenovo Storage E1012 or E1024 expansion enclosures. Intermix of E1012 and E1024 is supported. The enclosures can be added to the system non-disruptively.
The following table lists the models of the E1012 and E1024 expansion enclosure models.
Description | Part number |
LFF models | |
Lenovo Storage E1012 LFF Disk Expansion Single SAS IO Module, Rail Kit, 9x5 NBD | 64111B1 |
Lenovo Storage E1012 LFF Disk Expansion Dual SAS IO Module, Rail Kit, 9x5 NBD | 64111B2 |
SFF models | |
Lenovo Storage E1024 SFF Disk Expansion Single SAS IO Module, Rail Kit, 9x5 NBD | 64111B3 |
Lenovo Storage E1024 SFF Disk Expansion Dual SAS IO Module, Rail Kit, 9x5 NBD | 64111B4 |
The part number for the E1012 or E1024 includes the following items:
- One enclosure with two power supplies and fans and with one or two expansion modules installed
- Two 4.3m, 10A/100-250V, C13 to IEC 320-C14 Rack Power Cables
- Lenovo Storage SAN Rack Mount Kit - Rails 25"-36"
- Getting Started Guide
- Warranty Flyer
- Important Notices Flyer
- Documentation Flyer
The E1012 and E1024 support single and dual expansion module configurations. Standard models of the E1012 and E1024 ship with two expansion modules (see Table 4). Custom models of the E1012 and E1024 can be configured with one or two expansion modules. Single module configurations can be upgraded to dual module configurations non-disruptively. The number of expansion modules in the E1012 or E1024 must match the number of RAID controllers in the S3200.
Each expansion module has two 6 Gb SAS x4 ports (Mini-SAS SFF-8088 connectors) labelled IN and OUT. These ports are used for connections to the S3200 and for daisy chaining the E1012 and E1024 enclosures between each other. The expansion port on the S3200 controller is connected to the IN port on the expansion module, and the OUT port on the expansion module is connected to the IN port on the expansion module in the adjacent enclosure and so on.
The expansion connectivity topology for dual controller configurations is illustrated in the following figure. For single controller configurations, only Controller A path is present.
Figure 7. Expansion connectivity topology
The following table lists ordering information for the expansion modules and related connectivity options.
Description | Part number | Feature code (MTM 6411-HC3) | Max qty per one E1012 or E1024 |
Expansion modules | |||
Lenovo Storage Expansion SAS IO Module | 00WC085 | AT27 | 2 |
SAS expansion connectivity cables | |||
External MiniSAS 8088/MiniSAS 8088 0.6m cable | 00WE754 | AT1A | 2* |
External MiniSAS 8088/MiniSAS 8088 1m cable | 00WE755 | AT1B | 2* |
External MiniSAS 8088/MiniSAS 8088 2m cable | 00WE756 | AT1C | 2* |
* One cable per SAS expansion module.
Drives
The S3200 LFF chassis and the E1012 expansion enclosure support up to 12 LFF hot-swap drives, and the S3200 SFF chassis and the E1024 expansion enclosure support up to 24 SFF hot-swap drives.
The following table lists drive options for the S3200 LFF chassis and the E1012 expansion enclosure.
Description | Part number | Feature code (MTM 6411-HC2, 6411-HC3) | Max qty per one S3200 LFF or E1012 |
3.5-inch SAS hot-swap HDDs | |||
Lenovo Storage 3.5" 600GB 10K SAS HDD (2.5"in 3.5") | 00WC040 | AT21 | 12 |
Lenovo Storage 3.5" 900GB 10K SAS HDD (2.5"in 3.5)" | 00WC035 | AT1Z | 12 |
3.5-inch NL SAS hot-swap HDDs | |||
Lenovo Storage 3.5" 2TB 7.2k NL-SAS HDD | 00MM735 | AT1V | 12 |
Lenovo Storage 3.5" 4TB 7.2k NL-SAS HDD | 00MM730 | AT1W | 12 |
Lenovo Storage 3.5" 6TB 7.2k NL-SAS HDD | 00MM725 | AT1Y | 12 |
Lenovo Storage 3.5" 8TB 7.2k NL-SAS HDD | 00WE790 | AT47 | 12 |
Lenovo Storage 3.5" 10TB 7.2k NL-SAS HDD | 01DC631 | AU7W | 12 |
3.5-inch NL SAS hot-swap SEDs | |||
Lenovo Storage 3.5" 4TB 7.2k NL-SAS HDD (SED) | 00WC025 | AT1X | 12 |
3.5-inch SAS hot-swap SSDs (10 DWD) | |||
Lenovo Storage 3.5" 400GB SSD SAS (2.5" in 3.5") | 00WC030 | AT20 | 12 |
The following table lists drive options for the S3200 SFF chassis and the E1024 expansion enclosure.
Description | Part number | Feature code (MTM 6411-HC2, 6411-HC3) | Max qty per one S3200 SFF or E1024 |
2.5-inch SAS hot-swap HDDs | |||
Lenovo Storage 2.5" 300GB 15k SAS HDD | 00MM685 | AT1H | 24 |
Lenovo Storage 2.5" 600GB 10k SAS HDD | 00MM700 | AT1K | 24 |
Lenovo Storage 2.5" 600GB 15k SAS HDD | 00MM680 | AT1J | 24 |
Lenovo Storage 2.5" 900GB 10k SAS HDD | 00MM695 | AT1M | 24 |
Lenovo Storage 2.5" 1.2TB 10k SAS HDD | 00MM690 | AT1P | 24 |
Lenovo Storage 2.5" 1.8TB 10k SAS HDD | 00YG718 | ATSK | 24 |
2.5-inch SAS hot-swap SEDs | |||
Lenovo Storage 2.5" 600GB 10k SAS HDD (SED) | 00WC020 | AT1L | 24 |
Lenovo Storage 2.5" 900GB 10k SAS HDD (SED) | 00MM745 | AT1N | 24 |
Lenovo Storage 2.5" 1.2TB 10k SAS HDD (SED) | 00MM740 | AT1Q | 24 |
2.5-inch NL SAS hot-swap HDDs | |||
Lenovo Storage 2.5" 1TB 7.2k NL-SAS HDD | 00MM705 | AT1R | 24 |
Lenovo Storage 2.5" 2TB 7.2k NL-SAS HDD | 00YG698 | ATSL | 24 |
2.5-inch SAS hot-swap SSDs (1 DWD) | |||
Lenovo Storage 2.5" 3.84TB 1DWD SSD | 01CX868 | AUJN | 24 |
2.5-inch SAS hot-swap SSDs (3 DWD) | |||
Lenovo Storage 2.5" 400GB 3DWD SSD | 00YH988 | AU22 | 24 |
Lenovo Storage 2.5" 800GB 3DWD SSD | 00YH978 | AU21 | 24 |
Lenovo Storage 2.5" 1.6TB 3DWD SSD | 00YH968 | AU20 | 24 |
2.5-inch SAS hot-swap SSDs (10 DWD) | |||
Lenovo Storage 2.5" 400GB SSD (SAS) | 00MM720 | AT1S | 24 |
Lenovo Storage 2.5" 800GB SSD (SAS) | 00MM715 | AT1T | 24 |
Lenovo Storage 2.5" 1.6TB SSD (SAS) | 00MM710 | AT1U | 24 |
2.5-inch SAS hot-swap SED SSDs (10 DWD) | |||
Lenovo Storage 2.5” 400GB 10DWD SED SSD | 00YH983 | AU24 | 24 |
Lenovo Storage 2.5" 800GB 10DWD SED SSD | 00YH973 | AU23 | 24 |
Software
The S3200 comes standard with the following software features:
- Intelligent Real-time Tiering for HDDs
- Virtualized Storage Pools
- Thin Provisioning
- SSD Read Cache
- Rapid RAID Rebuild
- Snapshots - up to 128 targets.
The functionality of the S3200 can be expanded with the following optional software features:
- Intelligent Real-time Tiering for SSDs (Required for hybrid array configurations with SSDs and HDDs)
- Snapshots - up to 512 targets
- Snapshots - up to 1,024 targets
- Asynchronous replication
The following table lists the Feature on Demand (FoD) upgrades for the S3200 to enable optional software features. Each optional S3200 function is licensed on a per-system basis and covers both controller enclosure and all attached expansion units.
Description | Part number | Feature code |
---|---|---|
512 Snapshot Upgrade License | 01GV559 | AWGM |
1024 Snapshot Upgrade License | 01GV560 | AWGN |
SSD Data Tiering License* | 01GV561 | AWGP |
Asynchronous Replication License** | 01GV562 | AWGQ |
* Prior to the firmware version GL221R019-05, the SSD Data Tiering Upgrade option was required for all flash array configurations (a storage system with SSDs only; no HDDs installed) and for hybrid array configurations (a storage system with SSDs and HDDs). With the firmware version GL221R019-05 or later, the SSD Data Tiering Upgrade option is no longer required for all flash array configurations; however, it is required for hybrid configurations.
** Asynchronous Replication requires an FC and iSCSI Controller-based S3200 storage unit.
Software maintenance for standard software features is included in the S3200 base warranty and optional warranty extensions, which provides 3-year software support with the option to extend it up to 5 years in 1-year or 2-year increments (see the Warranty section for details).
Optional software features that are listed in Table 9 include 3-year software maintenance with the ability to extend it up to 5 years in 1-year or 2-year increments with the purchase of the software maintenance extension options that are listed in the following table.
Note: The S3200 must have active warranty coverage for the duration of an intended software maintenance extension period.
Description | Part number | Feature code (MTM 6411-HC2) |
Lenovo Storage 512 Snapshot Upgrade Maintenance 1 yr | 00WF825 | ATT4 |
Lenovo Storage 512 Snapshot Upgrade Maintenance 2 yr | 00WF829 | ATT5 |
Lenovo Storage 1024 Snapshot Upgrade Maintenance 1 yr | 00WF833 | ATT6 |
Lenovo Storage 1024 Snapshot Upgrade Maintenance 2 yr | 00WF837 | ATT7 |
Lenovo Storage SSD Data Tiering Maintenance 1 yr | 00WF841 | ATT8 |
Lenovo Storage SSD Data Tiering Maintenance 2 yr | 00WF845 | ATT9 |
Lenovo Storage Asynch Replication Maintenance 1yr | 00YG680 | ATTA |
Lenovo Storage Asynch Replication Maintenance 2yr | 00YG684 | ATTB |
Power cables
The S3200, E1012, and E1024 ship standard with two 4.3m, 10A/100-250V, C13 to IEC 320-C14 Rack Power Cables. Other power cable options are also available, and the part numbers and feature codes to order the power cables (two power cables are required per each S3200, E1012, and E1024) are listed in the following table.
Description | Part number | Feature code (MTM 6411-HC2, 6411-HC3) |
Rack power cables | ||
1.2m, 10A/100-250V, 2 Short C13s to Short C14 Rack Power Cable | 47C2487 | A3SS |
1.2m, 16A/100-250V, 2 Short C13s to Short C20 Rack Power Cable | 47C2491 | A3SW |
1.5m, 10A/100-250V, C13 to IEC 320-C14 Rack Power Cable | 39Y7937 | 6201 |
2.5m, 10A/100-250V, 2 Long C13s to Short C14 Rack Power Cable | 47C2488 | A3ST |
2.5m, 16A/100-250V, 2 Long C13s to Short C20 Rack Power Cable | 47C2492 | A3SX |
2.8m, 10A/100-250V, 2 Short C13s to Long C14 Rack Power Cable | 47C2489 | A3SU |
2.8m, 10A/100-250V, C13 to IEC 320-C14 Rack Power Cable | None* | 6311 |
2.8m, 10A/100-250V, C13 to IEC 320-C20 Rack Power Cable | 39Y7938 | 6204 |
2.8m, 16A/100-250V, 2 Short C13s to Long C20 Rack Power Cable | 47C2493 | A3SY |
4.1m, 10A/100-250V, 2 Long C13s to Long C14 Rack Power Cable | 47C2490 | A3SV |
4.1m, 16A/100-250V, 2 Long C13s to Long C20 Rack Power Cable | 47C2494 | A3SZ |
4.3m, 10A/100-250V, C13 to IEC 320-C14 Rack Power Cable | 39Y7932 | 6263 |
Line cords | ||
10A/125V C13 to NEMA 5-15P 4.3m line cord | 39Y7931 | 6207 |
10A/250V C13 to NEMA 6-15P 2.8m line cord | 46M2592 | A1RF |
Argentina 10A/250V C13 to IRAM 2073 2.8m line cord | 39Y7930 | 6222 |
Australia/NZ 10A/250V C13 to AS/NZ 3112 2.8m line cord | 39Y7924 | 6211 |
Brazil 10A/250V C13 to NBR 14136 2.8m line cord | 69Y1988 | 6532 |
China 10A/250V C13 to GB 2099.1 2.8m line cord | 39Y7928 | 6210 |
Denmark 10A/250V C13 to DK2-5a 2.8m line cord | 39Y7918 | 6213 |
European 10A/230V C13 to CEE7-VII 2.8m line cord | 39Y7917 | 6212 |
India 10A/250V C13 to IS 6538 2.8m line cord | 39Y7927 | 6269 |
Israel 10A/250V C13 to SI 32 2.8m line cord | 39Y7920 | 6218 |
Italy 10A/250V C13 to CEI 23-16 2.8m line cord | 39Y7921 | 6217 |
Japan 12A/125V C13 to JIS C-8303 2.8m line cord | 46M2593 | A1RE |
Korea 12A/250V C13 to KETI 2.8m line cord | 39Y7925 | 6219 |
South Africa 10A/250V C13 to SABS 164 2.8m line cord | 39Y7922 | 6214 |
Switzerland 10A/250V C13 to SEV 1011-S24507 2.8m line cord | 39Y7919 | 6216 |
Taiwan 15A/125V C13/CNS 10917 2.8m line cord | 00CG267 | 6402 |
United Kingdom 10A/250V C13 to BS 1363/A 2.8m line cord | 39Y7923 | 6215 |
Physical specifications
The S3200, E1012, and E1024 have the following dimensions and weight (approximate):
- LFF chassis
- Height: 87 mm (3.4 in.)
- Width: 447 mm (17.6 in.)
- Depth: 523 mm (20.6 in.)
- SFF chassis
- Height: 89 mm (3.5 in.)
- Width: 447 mm (17.6 in.)
- Depth: 519 mm (20.5 in.)
- Weight
- S3200 LFF: Minimum: 18.4 kg (40.6 lb); Maximum: 28.2 kg (62.2 lb)
- S3200 SFF: Minimum: 18.5 kg (40.8 lb); Maximum: 25.0 kg (55.2 lb)
- E1012: Minimum: 16.8 kg (37.0 lb); Maximum: 26.6 kg (58.6 lb)
- E1024: Minimum: 16.9 kg (37.2 lb); Maximum: 23.4 kg (51.6 lb)
Operating environment
The S3200, E1012, and E1024 are supported in the following environment:
- Air temperature:
- Operating: 5 °C to 40 °C (41 °F to 104 °F); decrease the maximum ambient temperature by 3.3 °C for every 1,000 m (3,280 ft)
- Storage: -10 °C to +60 °C (14 °F to 140 °F)
- Maximum altitude: 3,000 m (9,842 ft)
- Humidity:
- Operating: 8% to 85% (non-condensing)
- Storage: 5% to 90% (non-condensing)
- Electrical:
- 100 to 240 (nominal) V AC; 50 Hz to 60 Hz
- BTU output: 1488 Btu/hr (436 W)
- Noise level: 6.8 bels
Warranty
The S3200 has a three-year parts only warranty with 9x5/next business day (NBD) terms. Lenovo offers the service upgrades through warranty maintenance upgrades and post-warranty maintenance agreements with a well-defined scope of services, including service hours, response time, term of service, and service agreement terms and conditions.
Lenovo warranty service upgrade offerings are region-specific. Not all warranty service upgrades are available in every region. For more information about Lenovo warranty service upgrade offerings that are available in your region, refer to the Data Center Advisor and Configurator Tool (DCACT; formerly known as LESC):
http://lesc.lenovo.com
The following table explains warranty service definitions for the S3200 system in more detail.
Term | Description |
On-site service | A service technician will arrive at the client's location for equipment service. |
24x7x4 hour | A service technician is scheduled to arrive at the client's location within four hours after remote problem determination is completed. Lenovo provides service around the clock, every day, including Lenovo holidays. |
9x5x4 hour | A service technician is scheduled to arrive at the client's location within four business hours after remote problem determination is completed. Lenovo provides service 8:00 am - 5:00 pm in the client's local time zone, Monday-Friday, excluding Lenovo holidays. For example, if a customer reports an incident at 3:00 pm on Friday, the technician will arrive by 10:00 am the following Monday. |
9x5 next business day | A service technician is scheduled to arrive at the client's location on the business day after remote problem determination is completed. Lenovo provides service 8:00 am - 5:00 pm in the client's local time zone, Monday - Friday, excluding Lenovo holidays. Calls received after 4:00 pm local time require an extra business day for service dispatch. Next business day service is not guaranteed. |
In general, the types of Lenovo warranty service upgrades for the S3200 are as follows:
- Warranty and maintenance service upgrades:
- Onsite support for 9x5 NBD coverage
- 4-hour target response time with onsite, 9x5 or 24x7 service coverage
- Up to five years of warranty extension for all service levels in one or two year increments
- Hard Drive Retention
Lenovo's Hard Drive Retention service is a multi-drive hard drive retention offering that ensures your data is always under your control, regardless of the number of hard drives that are installed in your Lenovo system. In the unlikely event of a hard drive failure, you retain possession of your hard drive while Lenovo replaces the failed drive part. Your data stays safely on your premises, in your hands. The Hard Drive Retention service can be purchased in convenient bundles with our warranty upgrades and extensions.
Regulatory compliance
The S3200 conforms to the following regulations:
- UL 60950-1, 2nd Edition, 2007-03-27 (USA)
- CAN/CSA-C22.2 No 60950-1-07, 2nd Edition, 2007-03 (Canada)
- IEC 60950-1:2005 (2nd Edition); Am 1:2009
- EN 60950-1:2005, 2nd Edition, AM1 2009 (EU)
- CFR 47 Part 15 Subpart B Class A (USA FCC)
- ICES-003:2012, Class A (Canada)
- EN 55022: 2010 Class A (EU)
- EN 55024: 2010 (EU)
- ASNZS CISPR 22 -2009 Class A
- CNS 14338 (2006)
- KN22 Class A
- VCCI Technical Requirements 2012 Class A
- RoHS Directive 2011/65/EU
- EAC
- NOM
- BMSI
- CCC
Interoperability
Lenovo provides end-to-end storage compatibility testing to deliver interoperability throughout the network. The S3200 supports attachment to Lenovo ThinkSystem, System x, ThinkServer, and Flex System hosts by using SAS, iSCSI, or Fibre Channel storage connectivity protocols. Hybrid storage connectivity is also supported.
Note: Tables that are provided in this section are for ordering reference purposes only.
For end-to-end storage configuration support, refer to the Lenovo Storage Interoperation Center (LSIC):
https://datacentersupport.lenovo.com/us/en/lsic
Use the LSIC to select the known components of your configuration and then get a list all other supported combinations, with details about supported hardware, firmware, operating systems, and drivers, plus any additional configuration notes. View results on screen or export them to Excel.
SAS interoperability
The Lenovo SAS adapters that are listed in the following table are compatible with the S3200 SAS storage (direct attach).
Description | Part number |
ThinkSystem servers | |
ThinkSystem 430-8e SAS/SATA 12Gb HBA | 7Y37A01090 |
ThinkSystem 430-16e SAS/SATA 12Gb HBA | 7Y37A01091 |
System x servers | |
N2125 SAS/SATA HBA | 46C9010 |
N2225 SAS/SATA HBA | 00AE912 |
N2226 SAS/SATA HBA | 00AE916 |
ThinkServer servers | |
Lenovo ThinkServer 9300-8e PCIe 12Gb 8 Port External SAS Adapter by LSI | 4XB0F28703 |
iSCSI interoperability
The S3200 supports iSCSI attachments via standard 1 Gb or 10 Gb Ethernet network. Any compatible Ethernet switch, including Lenovo RackSwitch top of rack (TOR) switches and integrated Flex System Ethernet I/O modules, can be used to provide iSCSI connectivity with the S3200 iSCSI storage.
With software iSCSI initiators, any supported Lenovo 1 Gb Ethernet or 10 Gb Ethernet adapter is compatible with the S3200 iSCSI storage. For hardware iSCSI initiators (iSCSI HBAs), refer to the S2200/S3200 Interoperability Matrix.
The S3200 supports direct FC attachments and FC switch based attachments. Brocade and QLogic SAN switches can be used to provide FC connectivity with the S3200 FC storage.
The Lenovo FC adapters that are listed in the following table are compatible with the S3200 FC storage.
Description | Part number |
ThinkSystem servers - 32 Gb FC | |
ThinkSystem Emulex LPe32000-M2-L PCIe 32Gb 1-Port SFP+ Fibre Channel Adapter | 7ZT7A00517 |
ThinkSystem Emulex LPe32002-M2-L PCIe 32Gb 2-Port SFP+ Fibre Channel Adapter | 7ZT7A00519 |
ThinkSystem QLogic QLE2740 PCIe 32Gb 1-Port SFP+ Fibre Channel Adapter | 7ZT7A00516 |
ThinkSystem QLogic QLE2742 PCIe 32Gb 2-Port SFP+ Fibre Channel Adapter | 7ZT7A00518 |
System x servers - 16 Gb FC | |
Brocade 16Gb FC Dual-port HBA | 81Y1675 |
Brocade 16Gb FC Single-port HBA | 81Y1668 |
Emulex 16Gb FC Dual-port HBA | 81Y1662 |
Emulex 16Gb FC Single-port HBA | 81Y1655 |
QLogic 16Gb FC Single-port HBA | 00Y3337 |
QLogic 16Gb FC Dual-port HBA | 00Y3341 |
System x servers - 8 Gb FC | |
Emulex 8Gb FC Dual-port HBA | 42D0494 |
Emulex 8Gb FC Single-port HBA | 42D0485 |
QLogic 8Gb FC Dual-port HBA | 42D0510 |
QLogic 8Gb FC Single-port HBA | 42D0501 |
ThinkServer servers - 16 Gb FC | |
ThinkServer QLE2672 PCIe 16Gb 2 Port FC Adapter by Qlogic | 4XC0F28745 |
ThinkServer LPe16000B Single Port 16Gb FC HBA by Emulex | 4XB0F28653 |
ThinkServer LPe16002B-M6-L PCIe 16Gb 2 Port FC HBA by Emulex | 4XB0F28705 |
ThinkServer LPm16002-M6-L AnyFabric 16Gb 2 Port FC HBA by Emulex | 4XB0F28706 |
ThinkServer servers - 8 Gb FC | |
ThinkServer QLE2562 Dual Port 8Gb Fibre Channel HBA by Qlogic | 0C19482 |
ThinkServer LPe16002B-M8-L PCIe 8Gb 2 Port FC HBA by Emulex | 4XB0F28704 |
ThinkServer LPm15004-M8-L AnyFabric 8Gb 4 Port FC HBA by Emulex | 4XB0F28707 |
Flex System - 16 Gb FC | |
ThinkSystem Emulex LPm16002B-L Mezz 16Gb 2-Port Fibre Channel Adapter | 7ZT7A00521 |
ThinkSystem Emulex LPm16004B-L Mezz 16Gb 4-Port Fibre Channel Adapter | 7ZT7A00522 |
ThinkSystem QLogic QML2692 Mezz 16Gb 2-Port Fibre Channel Adapter | 7ZT7A00520 |
Flex System FC5052 2-port 16Gb FC Adapter | 95Y2386 |
Flex System FC5172 2-port 16Gb FC Adapter | 69Y1942 |
Flex System - 8 Gb FC | |
Flex System FC3052 2-port 8Gb FC Adapter | 95Y2375 |
Flex System FC3172 2-port 8Gb FC Adapter | 69Y1938 |
Networking switches
The following table lists the Ethernet and Fibre Channel rack mount switches offered by Lenovo that can be used in S3200 storage solutions.
Description | Part number |
1 Gb Ethernet (iSCSI connectivity) | |
Lenovo RackSwitch G7028 (Rear to Front) | 7159BAX |
Lenovo RackSwitch G7052 (Rear to Front) | 7159CAX |
Lenovo RackSwitch G8052 (Rear to Front) | 7159G52 |
10 Gb Ethernet (iSCSI connectivity) | |
Lenovo ThinkSystem NE1032 RackSwitch (Rear to Front) | 7159A1X |
Lenovo ThinkSystem NE1032T RackSwitch (Rear to Front) | 7159B1X |
Lenovo ThinkSystem NE1072T RackSwitch (Rear to Front) | 7159C1X |
Lenovo RackSwitch G8124E (Rear to Front) | 7159BR6 |
Lenovo RackSwitch G8264 (Rear to Front) | 7159G64 |
Lenovo RackSwitch G8264CS (Rear to Front) | 7159DRX |
Lenovo RackSwitch G8272 (Rear to Front) | 7159CRW |
Lenovo RackSwitch G8296 (Rear to Front) | 7159GR6 |
8 Gb FC | |
Lenovo B300, 8 ports activated, 8x 8Gb SWL SFPs, 1 PS, Rail Kit | 3873AR3 |
Lenovo B6505, 12 ports activated, 12x 8Gb SWL SFPs, 1 PS, Rail Kit | 3873AR4 |
Lenovo B6510, 24 ports activated, 24x 8Gb SWL SFPs, 2 PS, Rail Kit | 3873BR2 |
16 Gb FC | |
Lenovo ThinkSystem DB610S, 8 ports activated, 8x 16Gb SWL SFPs, 1 PS, Rail Kit | 6559D2Y |
Lenovo ThinkSystem DB610S, 24 ports activated, 24x 16Gb SWL SFP, Enterprise SW, 1 PS, Rail Kit | 6559D1Y |
Lenovo B6505, 12 ports activated w/ 16Gb SWL SFPs, 1 PS, Rail Kit | 3873AR5 |
Lenovo B6510, 24 ports activated w/ 16Gb SWL SFPs, 2 PS, Rail Kit | 3873BR3 |
32 Gb FC | |
Lenovo ThinkSystem DB610S, 8 ports activated, 1 PS, Rail Kit | 6559D3Y |
Lenovo ThinkSystem DB620S, 24 Ports Activated, 24x 32Gb SWL SFPs, 2 PS, Rail Kit | 6415G11 |
Lenovo ThinkSystem DB620S, 48 Ports Activated, 48x 32Gb SWL SFPs, 2 PS, Rail Kit | 6415G2A |
Lenovo ThinkSystem DB400D 32Gb FC Director, Up to 192 ports, 8U, Enterprise SW | 6684B2A |
Lenovo ThinkSystem DB800D 32Gb FC Director, Up to 384 ports, 14U, Enterprise SW | 6682B1A |
The following table lists the Ethernet and Fibre Channel integrated switches for Flex System that can be used in S3200 storage solutions.
Description | Part number |
10 Gb Ethernet (iSCSI connectivity) | |
Lenovo Flex System SI4091 10Gb System Interconnect Module | 00FE327 |
Lenovo Flex System Fabric SI4093 System Interconnect Module | 00FM518 |
Lenovo Flex System Fabric EN4093R 10Gb Scalable Switch | 00FM514 |
Lenovo Flex System Fabric CN4093 10Gb Converged Scalable Switch | 00FM510 |
Flex System EN4023 10Gb Scalable Switch | 94Y5212 |
Cisco Nexus B22 Fabric Extender for Flex System* | 94Y5350 |
Cisco Nexus B22 Fabric Extender with FET bundle for Flex System* | 94Y5355 |
16 Gb Fibre Channel | |
Flex System FC5022 16 Gb SAN Scalable Switch | 88Y6374 |
Flex System FC5022 24-port 16 Gb SAN Scalable Switch (includes two 16 Gb SFPs) | 00Y3324 |
Flex System FC5022 24-port 16 Gb ESB SAN Scalable Switch | 90Y9356 |
* Requires a supported Cisco Nexus top of rack switch.
Rack cabinets
The following table lists the rack cabinets offered by Lenovo that can be used in S3200 storage solutions.
Description | Part number |
25U S2 Standard Rack | 93072RX |
25U Static S2 Standard Rack | 93072PX |
42U S2 Standard Rack | 93074RX |
42U 1100mm Enterprise V2 Dynamic Rack | 93634PX |
42U 1100mm Enterprise V2 Dynamic Expansion Rack | 93634EX |
42U 1200mm Deep Dynamic Rack | 93604PX |
42U 1200mm Deep Static Rack | 93614PX |
42U Enterprise Rack | 93084PX |
42U Enterprise Expansion Rack | 93084EX |
For more information, see the list of Product Guides in the Rack cabinets category:
http://lenovopress.com/servers/options/racks
Power distribution units
The following table lists the the power distribution units (PDUs) that are offered by Lenovo that can be used in S3200 storage solutions.
Description | Part number |
---|---|
0U Basic PDUs | |
0U 36 C13/6 C19 24A/200-240V 1 Phase PDU with NEMA L6-30P line cord | 00YJ776 |
0U 36 C13/6 C19 32A/200-240V 1 Phase PDU with IEC60309 332P6 line cord | 00YJ777 |
0U 21 C13/12 C19 32A/200-240V/346-415V 3 Phase PDU with IEC60309 532P6 line cord | 00YJ778 |
0U 21 C13/12 C19 48A/200-240V 3 Phase PDU with IEC60309 460P9 line cord | 00YJ779 |
Switched and Monitored PDUs | |
0U 20 C13/4 C19 Switched and Monitored 24A/200-240V/1Ph PDU w/ NEMA L6-30P line cord | 00YJ781 |
0U 20 C13/4 C19 Switched and Monitored 32A/200-240V/1Ph PDU w/ IEC60309 332P6 line cord | 00YJ780 |
0U 18 C13/6 C19 Switched / Monitored 32A/200-240V/346-415V/3Ph PDU w/ IEC60309 532P6 cord | 00YJ782 |
0U 12 C13/12 C19 Switched and Monitored 48A/200-240V/3Ph PDU w/ IEC60309 460P9 line cord | 00YJ783 |
1U 9 C19/3 C13 Switched and Monitored DPI PDU (without line cord) | 46M4002 |
1U 9 C19/3 C13 Switched and Monitored 60A 3Ph PDU with IEC 309 3P+Gnd cord | 46M4003 |
1U 12 C13 Switched and Monitored DPI PDU (without line cord) | 46M4004 |
1U 12 C13 Switched and Monitored 60A 3 Phase PDU with IEC 309 3P+Gnd line cord | 46M4005 |
Ultra Density Enterprise PDUs (9x IEC 320 C13 + 3x IEC 320 C19 outlets) | |
Ultra Density Enterprise C19/C13 PDU Module (without line cord) | 71762NX |
Ultra Density Enterprise C19/C13 PDU 60A/208V/3ph with IEC 309 3P+Gnd line cord | 71763NU |
C13 Enterprise PDUs (12x IEC 320 C13 outlets) | |
DPI C13 Enterprise PDU+ (without line cord) | 39M2816 |
DPI Single Phase C13 Enterprise PDU (without line cord) | 39Y8941 |
C19 Enterprise PDUs (6x IEC 320 C19 outlets) | |
DPI Single Phase C19 Enterprise PDU (without line cord) | 39Y8948 |
DPI 60A 3 Phase C19 Enterprise PDU with IEC 309 3P+G (208 V) fixed line cord | 39Y8923 |
Front-end PDUs (3x IEC 320 C19 outlets) | |
DPI 30amp/125V Front-end PDU with NEMA L5-30P line cord | 39Y8938 |
DPI 30amp/250V Front-end PDU with NEMA L6-30P line cord | 39Y8939 |
DPI 32amp/250V Front-end PDU with IEC 309 2P+Gnd line cord | 39Y8934 |
DPI 60amp/250V Front-end PDU with IEC 309 2P+Gnd line cord | 39Y8940 |
DPI 63amp/250V Front-end PDU with IEC 309 2P+Gnd line cord | 39Y8935 |
Universal PDUs (7x IEC 320 C13 outlets) | |
DPI Universal 7 C13 PDU (with 2 m IEC 320-C19 to C20 rack power cord) | 00YE443 |
NEMA PDUs (6x NEMA 5-15R outlets) | |
DPI 100-127V PDU with fixed NEMA L5-15P line cord | 39Y8905 |
Line cords for PDUs that ship without a line cord | |
DPI 30a Line Cord (NEMA L6-30P) | 40K9614 |
DPI 32a Line Cord (IEC 309 P+N+G) | 40K9612 |
DPI 32a Line Cord (IEC 309 3P+N+G) | 40K9611 |
DPI 60a Cord (IEC 309 2P+G) | 40K9615 |
DPI 63a Cord (IEC 309 P+N+G) | 40K9613 |
DPI Australian/NZ 3112 Line Cord (32A) | 40K9617 |
DPI Korean 8305 Line Cord (30A) | 40K9618 |
For more information, see the list of Product Guides in the Power Distribution Units category:
http://lenovopress.com/servers/options/pdu
Uninterruptible power supply units
The following table list the uninterruptible power supply (UPS) units that are offered by Lenovo that can be used in S3200 storage solutions.
Description | Part number |
RT1.5kVA 2U Rack or Tower UPS (100-125VAC) | 55941AX |
RT1.5kVA 2U Rack or Tower UPS (200-240VAC) | 55941KX |
RT2.2kVA 2U Rack or Tower UPS (100-125VAC) | 55942AX |
RT2.2kVA 2U Rack or Tower UPS (200-240VAC) | 55942KX |
RT3kVA 2U Rack or Tower UPS (100-125VAC) | 55943AX |
RT3kVA 2U Rack or Tower UPS (200-240VAC) | 55943KX |
RT5kVA 3U Rack or Tower UPS (200-240VAC) | 55945KX |
RT6kVA 3U Rack or Tower UPS (200-240VAC) | 55946KX |
RT8kVA 6U Rack or Tower UPS (200-240VAC) | 55948KX |
RT11kVA 6U Rack or Tower UPS (200-240VAC) | 55949KX |
RT8kVA 6U 3:1 Phase Rack or Tower UPS (380-415VAC) | 55948PX |
RT11kVA 6U 3:1 Phase Rack or Tower UPS (380-415VAC) | 55949PX |
For more information, see the list of Product Guides in the Uninterruptible Power Supply Units category:
http://lenovopress.com/servers/options/ups
Lenovo Financial Services
Lenovo Financial Services reinforces Lenovo's commitment to deliver pioneering products and services that are recognized for their quality, excellence, and trustworthiness. Lenovo Financial Services offers financing solutions and services that complement your technology solution anywhere in the world.
We are dedicated to delivering a positive finance experience for customers like you who want to maximize your purchase power by obtaining the technology you need today, protect against technology obsolescence, and preserve your capital for other uses.
We work with businesses, non-profit organizations, governments and educational institutions to finance their entire technology solution. We focus on making it easy to do business with us. Our highly experienced team of finance professionals operates in a work culture that emphasizes the importance of providing outstanding customer service. Our systems, processes and flexible policies support our goal of providing customers with a positive experience.
We finance your entire solution. Unlike others, we allow you to bundle everything you need from hardware and software to service contracts, installation costs, training fees, and sales tax. If you decide weeks or months later to add to your solution, we can consolidate everything into a single invoice.
Our Premier Client services provide large accounts with special handling services to ensure these complex transactions are serviced properly. As a premier client, you have a dedicated finance specialist who manages your account through its life, from first invoice through asset return or purchase. This specialist develops an in-depth understanding of your invoice and payment requirements. For you, this dedication provides a high-quality, easy, and positive financing experience.
For your region specific offers please ask your Lenovo sales representative or your technology provider about the use of Lenovo Financial Services. For more information, see the following Lenovo website:
http://www.lenovo.com/us/en/landingpage/lenovo-financial-services
Related product families
Product families related to this document are the following:
Trademarks
Lenovo and the Lenovo logo are trademarks or registered trademarks of Lenovo in the United States, other countries, or both. A current list of Lenovo trademarks is available on the Web at https://www.lenovo.com/us/en/legal/copytrade/.
The following terms are trademarks of Lenovo in the United States, other countries, or both:
Lenovo®
System x®
ThinkServer®
ThinkSystem®
The following terms are trademarks of other companies:
Linux® is the trademark of Linus Torvalds in the U.S. and other countries.
Microsoft®, Excel®, Internet Explorer®, Windows Server®, and Windows® are trademarks of Microsoft Corporation in the United States, other countries, or both.
Other company, product, or service names may be trademarks or service marks of others.