Author
Updated
19 Nov 2025Form Number
LP2296PDF size
34 pages, 2.0 MB- Rack installation
- Physical specifications
- Operating environment
- Warranty and support
- Services
- Lenovo TruScale
- Regulatory compliance
- Interoperability
- Cluster interconnect
- Fibre Channel SAN switches
- Rack cabinets
- Power distribution units
- Uninterruptible power supply units
- Lenovo Financial Services
- Seller training courses
- Related publications and links
- Related product families
- Trademarks
Abstract
The Lenovo ThinkSystem DS3200, DS5200, and DS7200 are purpose-built performance-flash storage systems engineered to deliver high performance with the lowest latency, reliability, and simplicity for modern enterprise workloads.
The Lenovo ThinkSystem DS5200C is a purpose-built capacity-flash storage system engineered to deliver large capacities of flash, reliability, and simplicity for modern enterprise workloads optimized for.
These all-NVMe flash systems are optimized for block storage, offering robust data protection, seamless scalability, and consistent low-latency performance. Designed for organizations seeking efficient and secure storage infrastructure, the Lenovo ThinkSystem DS series supports mission-critical applications with advanced features such as autonomous ransomware protection, integrated data protection, and high availability.
This product guide provides essential technical and pre-sales information on the DS Series systems, including key features and specifications, supported configurations, and deployment guidelines. It is intended for technical specialists, sales engineers, and IT architects who want to learn more about the storage array and consider its use in their solutions.
Change History
Changes in the November 19, 2025 update:
- Updated the - Seller training courses section
- Included new DS content
Introduction
The Lenovo ThinkSystem DS3200, DS5200, DS7200, and DS5200C are all-NVMe flash SAN storage systems designed to provide simplicity, performance, and security for medium-sized enterprises. Powered by a SAN optimized version of the ONTAP storage management software, the DS Series delivers enterprise-class storage management capabilities with all leading SAN protocols. The DS Series is a perfect fit for a wide range of enterprise workloads, including high-performance databases, virtualization, enterprise applications, financial services, and other I/O-intensive applications requiring the highest levels of data security.
A single ThinkSystem DS3200 Storage Array scales up to 48 NVMe SSDs per HA Pair with the attachment of one Lenovo ThinkSystem DS240N 2U24 SFF Expansion Enclosure. A single ThinkSystem DS5200 Storage Array scales up to 72 NVMe SSDs per HA pair with the attachment of two Lenovo ThinkSystem DS240N 2U24 SFF Expansion Enclosures. A single ThinkSystem DS7200 Storage Array scales up to 120 NVMe SSDs per HA Pair with the attachment of four Lenovo ThinkSystem DS240N 2U24 SFF Expansion Enclosures, four expansions will require a supported 100Gb capable switch. A single DS5200C Storage Array scales up to 48 high-capacity NVMe SSDs per HA Pair the attachment of single DS240N expansion enclosure.
Did you know?
Lenovo ThinkSystem DS series Storage Arrays are an excellent choice for customers who are looking for the an end-to-end NVMe storage connectivity, advanced features and security of ONTAP software and wish to enable workloads using block storage protocols without the overhead of object storage.
Key features
The ThinkSystem DS series offers the following key features and benefits:
- Symmetric active-active for the highest levels of availability
- Inline and always-on storage efficiency to maximize the amount of data stored
- Support for all major SAN protocols, iSCSI, Fibre Channel (FC), NVMe/TCP, and NVMe/FC
- A single storage pool accessible to both controllers in an HA-pair to simplify provisioning
- Automatic storage balancing to maximize storage performance and minimize bottlenecks
- Autonomous ransomware protection to detect ransomware events in real-time
- SnapMirror active sync to enable zero data loss and zero downtime across sites for mission-critical workloads
- Simplified GUI for provisioning, management, data protection, and data security
- Tamper-proof SnapShots to provide immutable protection again ransomware and other unauthorize data changes
- Multi-admin verification to protect against unauthorized or accidental execution of sensitive operations
- Dual-active controllers (high availability pair) with automatic load balancing and failover
- Mirrored, battery-backed controller NVMEM
- Dual-port, SED, NVMe SSDs with automatic drive failure detection and rebuild
- Redundant, hot-swappable and customer replaceable hardware components, including transceivers, controllers, I/O modules, power supplies, and drives
- Non-disruptive controller and drive firmware upgrades
- Scale-out clustering, cluster any DS Series systems together
- Designed for 99.9999% availability with redundant hot-swap components, including controllers and I/O modules, power supplies, and non-disruptive firmware upgrades
Components and connectors
Front and rear view of the ThinkSystem DS series DS3200, DS5200, DS7200, and DS5200C units are identical.
The following figure shows the front of the DS5200

Figure 2. ThinkSystem DS5200 front view
The following figure shows the components of DS3200, DS5200, DS7200, and DS5200C controller enclosure
A single ThinkSystem DS3200, DS5200, DS7200, and DS5200C controller enclosure rear view controller includes the following components:
- 1 x redundant hot-swap power supply
- 4x Host Interface Card (HIC) slots:
- Slot 1 for host connections and storage expansion
- Slot 2 for host connections
- Slot 3 host connections and storage expansion
- Slot 4 for Cluster interconnect 25 GbE on the DS3200 and 100gbe on other models
- USB port
- 1GbE management port (RJ45)
- System LEDs
- Console port
Per controller, the four Host Interface Cards provide one of the following combinations of ports:
- 4-port 10Gb BaseT RJ45 (10Gbs, 1Gbs, and 100Mbs)
- 4-port 10/25 GbE
- 2-port 40/100 GbE (and for expansion storage 2pt 100 GbE ports)
- 4-port, 64Gb Fiber Channel, SFP+ (16/32/64 Gbs)
- All HICs require SFPs and optical cables or DAC cables and are configured separately
- All ethernet SFPs run at posted speed only and do not support dual line rates
The following figure shows the front of the ThinkSystem DS240N 2U SFF NVMe expansion enclosure.

Figure 4. ThinkSystem DS240N 2U SFF NVMe expansion enclosure front view
The following figure shows the rear of the DS240N expansion enclosure.

Figure 5. ThinkSystem DS240N 2U SFF NVMe expansion enclosure rear view
The rear of the ThinkSystem DS240N 2U SFF NVMe expansion enclosure includes the following components:
- Two redundant hot-swap NVMe I/O Modules; each with the following ports:
- Two 100 GbE QSFP28 expansion ports for connections to the controller enclosure.
- Two redundant hot-swap power supplies
System specifications
The following table lists the ThinkSystem DS3200, DS5200, DS7200, and DS5200C storage system specifications.
Note: The supported hardware options, software features, and interoperability listed in this product guide are based on the ONTAP software version 9.17.1. For details about specific software releases that introduced support for certain hardware options and software features, refer to the Release notes of the particular software release for the ThinkSystem DS3200, DS5200, DS7200, and DS5200C that can be found at: http://datacentersupport.lenovo.com
| Attribute | Specification | ||||
|---|---|---|---|---|---|
| Model | DS7200 | DS5200 | DS3200 | DS5200C | |
| Machine type | 7DP4 | 7DP5 | 7DP6 | 7DP7 | |
| Form factor |
2U rack mount |
||||
| System memory (per HA pair) | 256 GB | 128 GB | 128 GB | 128 GB | |
| System NVMEM (per HA pair) | 32 GB | 16 GB | 16 GB | 16 GB | |
| Cluster Scaling Limit SAN (HA pair) | 6 HA pairs | 4 HA pairs | 3 HA pairs | 4 HA pairs | |
| Drive bays (per HA pair) | 24 | 24 | 24 | 24 | |
| Max NVMe SSDs (per HA pair) | 120 | 72 | 48 | 48 | |
| Drive Minimum (per HA pair) | 8 | 8 | 8 | 8 | |
| Capacity Minimum (per HA pair) | 68 TB | No minimum | No minimum | No minimum | |
| Direct Connected Expansions (DS240N) (per HA pair) | 2 | 2 | 1 | 1 | |
| Switch Connected Expansions (DS240N) (per HA pair) | 4 | 2 | 0 | 0 | |
| Cluster Connected Expansions (DS240N) (per HA pair) | 4x 100Gbe | 4x 100Gbe | 4x 25Gbe | 4x 100Gbe | |
|
Host/Storage HIC options (per HA Pairs)† |
Select up to (6) Host/Storage HICs. Ordered in pairs | ||||
|
|||||
| RAID levels | RAID-DP | ||||
| Supported NVMe SSD capacities | 1.92 TB, 3.84 TB, 7.68 TB, and 15.36 TB NVMe SED SSDs | 15.36 TB, 30.72 TB NVMe SED SSDs | |||
| Storage Protocols |
FC, iSCSI, NVMe/FC, NVMe/TCP |
||||
| Category 1 Host operating systems* | Microsoft Windows Server, Red Hat Enterprise Linux, SUSE Linux Enterprise Server, VMware ESXi | ||||
| Category 2 Host operating systems** | Oracle Linux, Oracle VM, Citrix Hypervisor, CentOS, Ubuntu, Solaris. For version details, see the latest Category 2 Interoperability Matrix, available as a download from Lenovo Storage Interoperation Center (LSIC) | ||||
| Standard software features | RAID data protection, SnapShots, instant volume copy (FlexClone), storage quality of service (QoS), thin provisioning, compression, deduplication, compaction, encryption, disk-based backup (SnapVault), application-aware backup (SnapCenter), quick data recovery (SnapRestore), clustering, and synchronous and asynchronous replication (SnapMirror) | ||||
| Cooling | Redundant cooling with built-in power supply fans | ||||
|
Power Supply |
Two redundant hot-swap 1600 W Titanium AC power supplies | ||||
| 200 to 240 | 200 to 240 | 100 to 120 200 to 240 Autosensing |
200 to 240 | ||
| Hot-swap parts | Controllers, I/O modules, drives, power supplies, and transceivers and DAC cables | ||||
| Management ports | 1x 1 GbE port (UTP, RJ-45) per controller for out-of-band management | ||||
| 2x Serial console ports (RJ-45 and Micro-USB) for system configuration | |||||
| Management interfaces | ThinkSystem Storage Manager web-based GUI; SSH CLI; Serial console CLI; SNMP, email, and syslog alerts. | ||||
| Security features | Secure Socket Layer (SSL), Secure Shell (SSH), user level security, role-based access control (RBAC), LDAP authentication. Multi-admin verification, Autonomous ransomware protection | ||||
| Warranty and support | Three-, four-, or five-year customer-replaceable unit and onsite limited warranty with selectable service levels: 9x5 service coverage next business day (NBD) onsite response (Foundation) or 24x7 service coverage with 4-hour onsite response (Essential). Premier Support is also available. Software support is included in the Foundation or Essential Service for the duration of the warranty period. | ||||
| Dimensions |
|
||||
| Weight (fully configured) | 60.7 lb (27.5 kg) | ||||
* For Category 1 operating system support information, see Lenovo Storage Interoperation Center (LSIC).
** For Category 2 operating system support information, see the latest Category 2 Interoperability Matrix. Go to the Lenovo Storage Interoperation Center (LSIC) home page and scroll down to the Lenovo Information section and click the Download Lenovo 3rd party of interop matrix link.
† For a detailed list of configuration limits and restrictions for a specific version of the software, refer to the Lenovo Data Center Support website:
http://datacentersupport.lenovo.com
Controller enclosures
Preconfigured and factory-integrated models of the ThinkSystem DS Series SAN optimized Storage Arrays are configured by using the Lenovo Data Center Solution Configurator (DCSC): http://dcsc.lenovo.com
The following table lists the CTO base model for the ThinkSystem DS Series.
The models of the DS Series ship with the following items:
- One chassis with the following components:
- Two controllers
- Two power supplies
- Rack Mount Kit
- 2m USB Cable (USB Type A to Micro-USB)
- Documentation flyer
- Two customer-configured power cables
Controllers
The ThinkSystem DS Series enclosures ship with two NVMe controllers. A controller provides interfaces for host connectivity, management, and internal drives, and it runs ONTAP storage management software.
The ThinkSystem DS series models are 2U rack-mount enclosures that include two controllers, with 128GB of RAM per DS7200 controller and 64GB of RAM for other models.and 24x NVMe U.2 SFF drives. Each controller provides adapter support for 10/25 GbE, 40/100 GbE or 16/32/64 Gb Fibre Channel (FC) ports for host connectivity, depending on the configuration.
The following table lists the RAM and NVMEM per controller
Each DS Series controller requires two cluster interconnect ports cabled directly for a dual-controller HA pair/two-node switchless cluster or to a supported switch for a switched cluster interconnect with multiple dual-controller HA pairs. See system specifications for cluster limits.
Each DS Series controller also has the following host interfaces:
- 1x slot for Cluster interconnect (Configured in the Cluster Port Adapter section)
- DS3200 2x 25 GbE ports using 4x 10/25 GbE card (C4AC)
- DS5200 2x 100 GbE ports using 2x 40/100 GbE card (C4AA)
- DS7200 2 x 100 GbE ports using 2x 40/100 GbE card (C4AA)
- DS5200C 2 x 100 GbE ports using 2x 40/100 GbE card (C4AA)
- 3x slots for host interfaces using HIC adapters; choices of HIC adapters are:
- 25GbE HIC, with 4x 10/25 GbE SFP28 (DAC cables or SW fiber optic cables, LC) (C4AC)
- 100GbE HIC, with 2x 40/100 GbE QSFP28 (DAC cables or SW fiber optic cables, MPO) (C4AA)
- 10Gb BaseT, with 4x 100Mbs/1 Gbs/10Gbs RJ45 (C4A9)
- Fibre Channel HIC, with 4x 16/32/64 Gb FC SFP+ host ports (SW fiber optic cables, LC)(C4A8)
- All HICs require SFPs and optical cables or DAC cables
- All ethernet SFPs run at posted speed only and do not support dual line rates
Two controllers are required for selection and must have the same HIC adapters installed. The use of a DS240N expansion enclosure requires a 100GbE HIC for connectivity installed in slot 1 in each controller.
The following table lists the controllers for the ThinkSystem DS Series Storage Arrays and supported connectivity options.
Tip: The Fibre Channel HIC does not include transceivers. Transceivers are selected separately.
The following table lists the supported optical and copper cables.
Tip: The 100GbE cables used to connect the DS240N expansion enclosure are configure with the DS240N.
Expansion enclosures
The ThinkSystem DS Series support attachment of ThinkSystem DS240N 2U24 expansions. The expansion enclosure can be added to the system non-disruptively.
Note: A maximum of two DS240N expansion units are supported via direct attach. More than 2x expansion units require a storage switch (SN2100, Cisco C9336C-FX2). A switch can be used to connect from one up to the maximum number of supported expansions. If a switch is used all expansions will be connected through the switch.
The following table lists the CTO base models for the ThinkSystem DS Series expansion enclosures.
The ThinkSystem DS240N expansion enclosure ships with two NVMe I/O expansion modules. Each NVMe I/O expansion module provides two external 100 GbE QSFP28 ports (labeled Ports A and B) that are used for direct-attach connections to the ThinkSystem DS Series enclosure.
The ThinkSystem DS Series enclosures support the following expansions:
- DS3200 direct connected 1x DS240N - 48 NVMe SSDs
- DS5200 direct connected 2x DS240N - 72 NVMe SSDs
- DS7200 direct connected 2x DS240N - 72 NVMe SSDs (Switch connected: 4x DS240N - 120 NVMe SSDs)
- DS5200C direct connected 1x DS240N - 48 NVMe SSDs
Configuration notes:
- 100GbE adapter (C4W5) required to support DS240N expansion.
- For example to attach 1x DS240N, requires four 100G QSFP28 DAC cables per expansion for directly connecting the expansion to the base enclosure (two from each controller).
The models of the ThinkSystem DS240N ship with the following items:
- One chassis with the following components:
- Two NVMe I/O modules
- Two power supplies
- Rack Mount Kit
- Publications Flyer
- Two customer-configured power cables
- Four customer-configured 100G QSFP28 Passive DAC cables
The following table lists ordering information for the NVMe expansion enclosure connectivity options.
Drives
The ThinkSystem DS Series base enclosures and DS240N expansion enclosures each support up to 24 SFF hot-swap drives, in packs of 2 drives.
- All non-FIPS drives are Self-Encrypting Drives (SED)
- FIPS and non-FIPS drives CAN NOT be mixed in the same system
- All systems require a minimum of 8-drives (4-drive packs)
- For factory-installed drive packs, all drives in the enclosure must be of the same type and capacity
- Expansion enclosures require a minimum of 4-drives ( 2-drive packs)
The following tables list the drive options for internal storage for each base enclosure and expansions.
The Lenovo ThinkSystem DS Series enclosures:
The Lenovo ThinkSystem Expansion enclosures:
Software
In this section:
Feature bundles
Controller software for the Lenovo ThinkSystem DS Series is only available in a single bundle:
- Storage All SAN Complete Bundle Offering (Feature CCQ9)
The following table summarizes the features in each bundle for the DS3200, DS5200, DS7200 and DS5200C.
* Requires the encryption version of ONTAP. See the ONTAP software section
† Not available in PRC
The features are summarized as follows:
- RAID-DP data protection: Provides the flexibility to choose the level of data protection required and helps improve performance and availability with built-in spare capacity and by distributing data across all physical drives in the aggregate, sustaining to up to two (RAID-DP) concurrent drive failures.
- All Flash Array (AFA) capability: Meets the demand for higher speed, lower latency storage and provides higher IOPS and bandwidth with lower power usage and total cost of ownership than hybrid or HDD-based solutions.
- Thin provisioning: All capacity is thin provisioned to optimize efficiency by allocating storage space based on the minimum space required by each application at any given time, so that applications consume only the space they are actually using, not the total space that has been allocated to them, which allows customers to purchase storage they need today and add more as application requirements grow.
- Compression: Provides transparent inline and post-process data compression to reduce the amount of storage that customers need to purchase and manage.
- Compaction: Enhances compression to further reduce the amount of storage that customers need to purchase and manage.
- Deduplication: Performs general-purpose deduplication for removal of redundant data to reduce the amount of storage that customers need to purchase and manage.
- Snapshots: Enables creation of read-only copies of data for backup, parallel processing, testing, and development, and have the copies available almost immediately.
- Encryption: Provides software-based encryption for data at rest for enhanced data security with the traditional drives and embedded key management (requires the encryption-capable version of the ONTAP software).
- Balanced placement: Provides automated workload distribution across the cluster to help increase utilization and performance.
- Dynamic capacity expansion: Allows the capacity of a volume or aggregate to be expanded by adding new physical drives.
- Adaptive Quality of Service: Simplifies operations and maintains consistent workload performance by defining QoS policies and automatically adjusting storage resources to respond to workload changes.
- SnapRestore: Enables quick recovery of data by reverting a local volume or file to its previous state from a particular snapshot copy stored on the file system.
- FlexClone: References snapshot metadata to create writable point-in-time copies of a volume.
- SnapMirror asynchronous replication: Provides storage system-based data replication between the storage systems containing source (local) and destination (remote) volumes by using asynchronous (at specified regular intervals) data transfers over IP communication links.
- SyncMirror data protection: Adds extra level of data protection and availability by mirroring a pair of RAID aggregates.
- Trusted Platform Module (TPM): For encryption enabled systems. The encryption keys for the onboard key manager (OKM) are no longer stored in the boot device, but instead are stored in the physical TPM for systems so equipped, offering greater security and protection. Moving to the TPM is a nondisruptive process.
- Data Protection Optimized (DPO): Increases the amount of concurrent SnapMirror sessions per node, as well as improving SnapMirror performance to the cluster.
- SnapMirror active sync: Non-disruptive failover active-active cross site clusters. Based on existing SnapMirror Synchronous Replication. Offers Zero data loss, zero downtime. You do not have to failover the application. If there is a failure the application will continue to run and there will be no need to restart.
- SnapMirror synchronous replication: Provides storage system-based data replication between the storage systems containing source (local) and destination (remote) volumes by using synchronous (as soon as the data is written to the source volume)
- SnapVault disk-based storage backup: Enables data stored on multiple systems to be backed up to a central, secondary system quickly and efficiently as read-only snapshot copies.
- SnapCenter: Provides application- and virtual machine-aware backup and restoration of data by using the Snapshots technology and leverages the SnapMirror capabilities of storage systems to provide onsite or offsite backup set mirroring for disaster recovery.
- SnapMirror Cloud: A backup and recovery technology designed for ONTAP users who want to transition their data protection workflows to the cloud. SnapMirror Cloud is an extension to the family of SnapMirror replication technologies. While SnapMirror is frequently used for ONTAP-to-ONTAP backups, SnapMirror Cloud uses the same replication engine to transfer Snapshot copies for ONTAP to S3-compliant object storage backups.
- Multitenant Key Management (MTKM): Provides the ability for individual tenants or storage virtual machines (SVMs) to maintain their own keys through KMIP for NVE. With multitenant external key management, you can centralize your organization’s key management functions by department or tenant while inherently confirming that keys are not stored near the assets. This approach decreases the possibility of compromise.
- Autonomous Ransomware Protection (ARP): Uses workload analysis in to proactively detect and warn about abnormal activity that might indicate a ransomware attack. When an attack is suspected, anti-ransomware also creates new Snapshot backups, in addition to existing protection from scheduled Snapshot copies. New to ONTAP 9.11: Optional multi-admin verification to approve administration functions that could result in data loss.
- SnapLock data protection: Creates Write-Once-Read-Many (WORM) non-rewritable, non-erasable data on hard disk drives to prevent files from being altered or deleted until a predetermined or default retention date.
ONTAP software versions
The following table lists the software selection options for the DS3200, DS5200, DS7200 and DS5200C. The table also indicates which markets each version is available in.
Software maintenance is included in the DS3200, DS5200, DS7200 and DS5200C warranty and support (see Warranty and support for details).
Management
The ThinkSystem DS Series supports the following management interfaces:
- Lenovo ThinkSystem Storage Manager, a web-based interface via HTTPS for single-system management or centralized management of the cluster of systems, that runs on the storage system itself and requires only a supported browser (Microsoft Internet Explorer, Google Chrome, or Mozilla Firefox), so there is no need for a separate console or plug-in.
- Command line interface (CLI) via SSH or through serial console.
- Syslog, SNMP, and e-mail notifications.
Power supplies and cables
The ThinkSystem DS Series base enclosures and the DS240N 2U24 SFF expansion enclosures ship with two redundant hot-swap 1600 W (200-240 V) Platinum AC power supplies, each with an IEC 320-C14 connector.
Each ThinkSystem DS Series enclosure requires the selection of two power cables.
Note: A 110V power source is only supported on the DS3200. Included power supply is auto-sensing.
Rack installation
The individually shipped ThinkSystem DS Series and DS240N enclosures come with the ThinkSystem Storage Rack Mount Kit 2U24 listed in the following table.
| Feature code | Description | Quantity |
|---|---|---|
| B6Y6 | Lenovo ThinkSystem NVMe Rail Kit 4 post | 1 |
When the ThinkSystem DS Series enclosures are factory-integrated and shipped installed in a rack cabinet, the rack mount kits that support Ship-in-Rack (SIR) capabilities are derived by the configurator. The SIR-capable rack mount kits are listed in the following table.
| Feature code | Description | Quantity |
|---|---|---|
| B6Y7 | ThinkSystem NVMe Adjustable Rail Kit | 1 |
The following table summarizes the rack mount kit features and specifications.
* The majority of the enclosure components can be serviced from the front or rear of the enclosure, which does not require the removal of the enclosure from the rack cabinet.
** If a 0U PDU is used, the rack cabinet must be at least 1000 mm (39.37 in.) deep for 2U24 enclosures.
^ Measured when mounted on the rack, from the front surface of the front mounting flange to the rear most point of the rail.
Physical specifications
The ThinkSystem DS Series physical specifications are in the following table:
The ThinkSystem DS240N expansion specifications are in the following table:
Operating environment
The ThinkSystem DS Series enclosures are supported in the following environment:
The ThinkSystem DS240N expansion supports in the following environment:
Warranty and support
The DS3200, DS5200, DS7200, DS5200C and DS240N expansion enclosures have a 3-year warranty.
Our global network of regional support centers offers consistent, local-language support enabling you to vary response times and level of service to match the criticality of your support needs:
- Standard Next Business Day – Best choice for non-essential systems requiring simple maintenance.
- Premier Next Business Day – Best choice for essential systems requiring technical expertise from senior-level Lenovo engineers.
- Premier 24x7 4-Hour Response – Best choice for systems where maximum uptime is critical.
- Premier Enhanced Storage Support 24x7 4-Hour Response – Best choice for storage systems where maximum uptime is critical.
For more information, consult the brochure Lenovo Operational Support Services for Data Centers Services.
Services
Lenovo Data Center Services empower you at every stage of your IT lifecycle. From expert advisory and strategic planning to seamless deployment and ongoing support, we ensure your infrastructure is built for success. Our comprehensive services accelerate time to value, minimize downtime, and free your IT staff to focus on driving innovation and business growth.
Note: Some service options may not be available in all markets or regions. For more information, go to https://lenovolocator.com/. For information about Lenovo service upgrade offerings that are available in your region, contact your local Lenovo sales representative or business partner.
In this section:
- Lenovo Advisory Services
- Lenovo Plan & Design Services
- Lenovo Deployment, Migration, and Configuration Services
- Lenovo Support Services
- Lenovo Managed Services
- Lenovo Sustainability Services
Lenovo Advisory Services
Lenovo Advisory Services simplify the planning process, enabling customers to build future-proofed strategies in as little as six weeks. Consultants provide guidance on projects including VM migration, storage, backup and recovery, and cost management to accelerate time to value, improve cost efficiency, and build a flexibly scalable foundation.
- Assessment Services
An Assessment helps solve your IT challenges through an onsite, multi-day session with a Lenovo technology expert. We perform a tools-based assessment which provides a comprehensive and thorough review of a company's environment and technology systems. In addition to the technology based functional requirements, the consultant also discusses and records the non-functional business requirements, challenges, and constraints. Assessments help organizations like yours, no matter how large or small, get a better return on your IT investment and overcome challenges in the ever-changing technology landscape.
- Design Services
Professional Services consultants perform infrastructure design and implementation planning to support your strategy. The high-level architectures provided by the assessment service are turned into low level designs and wiring diagrams, which are reviewed and approved prior to implementation. The implementation plan will demonstrate an outcome-based proposal to provide business capabilities through infrastructure with a risk-mitigated project plan.
Lenovo Plan & Design Services
Unlock faster time to market with our tailored, strategic design workshops to align solution approaches with your business goals and technical requirements. Leverage our deep solution expertise and end-to-end delivery partnership to meet your goals efficiently and effectively.
Lenovo Deployment, Migration, and Configuration Services
Optimize your IT operations by shifting labor-intensive functions to Lenovo's skilled technicians for seamless on-site or remote deployment, configuration, and migration. Enjoy peace of mind, faster time to value, and comprehensive knowledge sharing with your IT staff, backed by our best-practice methodology.
- Deployment Services for Storage and ThinkAgile
A comprehensive range of remote and onsite options tailored specifically for your business needs to ensure your storage and ThinkAgile hardware are fully operational from the start.
- Hardware Installation Services
A full-range, comprehensive setup for your hardware, including unpacking, inspecting, and positioning components to ensure your equipment is operational and error-free for the most seamless and efficient installation experience, so you can quickly benefit from your investments.
- DM/DG/DE Health Check Services
Our experts perform proactive checks of your Firmware and system health to ensure your machines are operating at peak and optimal efficiency to maximize up-time, avoid system failures, ensure the security of IT solutions and simplify maintenance.
- Factory Integrated Services
A suite of value-added offerings provided during the manufacturing phase of a server or storage system that reduces time to value. These services aim at improving your hardware deployment experience and enhance the quality of a standard configuration before it arrives at your facility.
Lenovo Support Services
In addition to response time options for hardware parts, repairs, and labor, Lenovo offers a wide array of additional support services to ensure your business is positioned for success and longevity. Our goal is to reduce your capital outlays, mitigate your IT risks, and accelerate your time to productivity.
- Premier Support for Data Centers
Your direct line to the solution that promises the best, most comprehensive level of support to help you fully unlock the potential of your data center.
- Premier Enhanced Storage Support (PESS)
Gain all the benefits of Premier Support for Data Centers, adding dedicated storage specialists and resources to elevate your storage support experience to the next level.
- Committed Service Repair (CSR)
Our commitment to ensuring the fastest, most seamless resolution times for mission-critical systems that require immediate attention to ensure minimal downtime and risk for your business. This service is only available for machines under the Premier 4-Hour Response SLA.
- Multivendor Support Services (MVS)
Your single point of accountability for resolution support across vast range of leading Server, Storage, and Networking OEMs, allowing you to manage all your supported infrastructure devices seamlessly from a single source.
- Keep Your Drive (KYD)
Protect sensitive data and maintain compliance with corporate retention and disposal policies to ensure your data is always under your control, regardless of the number of drives that are installed in your Lenovo server.
- Technical Account Manager (TAM)
Your single point of contact to expedite service requests, provide status updates, and furnish reports to track incidents over time, ensuring smooth operations and optimized performance as your business grows.
- Enterprise Software Support (ESS)
Gain comprehensive, single-source, and global support for a wide range of server operating systems and Microsoft server applications.
For more information, consult the brochure Lenovo Operational Support Services for Data Centers.
Lenovo Managed Services
Achieve peak efficiency, high security, and minimal disruption with Lenovo's always-on Managed Services. Our real-time monitoring, 24x7 incident response, and problem resolution ensure your infrastructure operates seamlessly. With quarterly health checks for ongoing optimization and innovation, Lenovo's remote active monitoring boosts end-user experience and productivity by keeping your data center's hardware performing at its best.
Lenovo Managed Services provides continuous 24x7 remote monitoring (plus 24x7 call center availability) and proactive management of your data center using state-of-the-art tools, systems, and practices by a team of highly skilled and experienced Lenovo services professionals.
Quarterly reviews check error logs, verify firmware & OS device driver levels, and software as needed. We’ll also maintain records of latest patches, critical updates, and firmware levels, to ensure you systems are providing business value through optimized performance.
Lenovo Sustainability Services
- Asset Recovery Services
Lenovo Asset Recovery Services (ARS) provides a secure, seamless solution for managing end-of-life IT assets, ensuring data is safely sanitized while contributing to a more circular IT lifecycle. By maximizing the reuse or responsible recycling of devices, ARS helps businesses meet sustainability goals while recovering potential value from their retired equipment. For more information, see the Asset Recovery Services offering page.
- CO2 Offset Services
Lenovo’s CO2 Offset Services offer a simple and transparent way for businesses to take tangible action on their IT footprint. By integrating CO2 offsets directly into device purchases, customers can easily support verified climate projects and track their contributions, making meaningful progress toward their sustainability goals without added complexity.
- Lenovo Certified Refurbished
Lenovo Certified Refurbished offers a cost-effective way to support IT circularity without compromising on quality and performance. Each device undergoes rigorous testing and certification, ensuring reliable performance and extending its lifecycle. With Lenovo’s trusted certification, you gain peace of mind while making a more sustainable IT choice.
Lenovo TruScale
Lenovo TruScale XaaS is your set of flexible IT services that makes everything easier. Streamline IT procurement, simplify infrastructure and device management, and pay only for what you use – so your business is free to grow and go anywhere.
Lenovo TruScale is the unified solution that gives you simplified access to:
- The industry’s broadest portfolio – from pocket to cloud – all delivered as a service
- A single-contract framework for full visibility and accountability
- The global scale to rapidly and securely build teams from anywhere
- Flexible fixed and metered pay-as-you-go models with minimal upfront cost
- The growth-driving combination of hardware, software, infrastructure, and solutions – all from one single provider with one point of accountability.
For information about Lenovo TruScale offerings that are available in your region, contact your local Lenovo sales representative or business partner.
Regulatory compliance
The ThinkSystem DS Series enclosures conform to the following regulations:
- United States: FCC Part 15, Class A; UL 60950-1
- Canada: ICES-003, Class A; CAN/CSA-C22.2 60950-1
- Mexico NOM
- European Union: CE Mark (EN55032 Class A, EN55024, IEC/EN60950-1); ROHS Directive 2011/65/EU
- Russia, Kazakhstan, Belarus: EAC
- China: CCC GB 4943.1, GB 17625.1, GB 9254 Class A; CELP; CECP
- Japan: VCCI, Class A
- Taiwan: BSMI CNS 13438, Class A; CNS 14336-1
- Korea KN32/35, Class A
- Australia/New Zealand: AS/NZS CISPR 22 Class A
Interoperability
Lenovo provides end-to-end storage compatibility testing to deliver interoperability throughout the network. The ThinkSystem DS Series all-Flash SAN Storage Array supports attachment to Lenovo servers by using NVMe over Fibre Channel (NVMe/FC), iSCSI, and Fibre Channel storage connectivity.
For end-to-end storage configuration support, refer to the Lenovo Storage Interoperation Center (LSIC):
https://datacentersupport.lenovo.com/us/en/lsic
Use the LSIC to select the known components of your configuration and then get a list all other supported combinations, with details about supported hardware, firmware, operating systems, and drivers, plus any additional configuration notes. View results on screen or export them to Excel.
Cluster interconnect
The following Ethernet storage switch can be used with the ThinkSystem DS3200, DS5200, DS7200 and DS5200C for cluster interconnect configurations.
- Cisco 9336C-FX2 (preferred switch)
- BES-53248 (withdrawn; still supported for existing installations)
- NVIDIA SN2100 (withdrawn; still supported for existing installations)
** The SN2100 switch can be used with the ThinkSystem DS3200, DS5200, DS7200 and DS5200C for cluster interconnect.
For more information, see the following
- Cisco Nexus 9300 Series Network Switches Product Guide:
https://lenovopress.lenovo.com/lp2034-cisco-nexus-9300-series-network-switches - NVIDIA SN2100 16-port 100Gb Ethernet Storage Switch Article:
https://lenovopress.lenovo.com/lp1756-nvidia-sn2100-100gb-ethernet-storage-switch - BES-53248 Ethernet Storage Switch:
https://lenovopress.lenovo.com/lp1226-bes-53248-ethernet-storage-switch-lenovo
Fibre Channel SAN switches
Lenovo offers the ThinkSystem DB Series of Fibre Channel SAN switches for high-performance storage expansion. See the DB Series product guides for models and configuration options:
- ThinkSystem DB Series SAN Switches:
https://lenovopress.com/storage/switches/rack#rt=product-guide
Rack cabinets
The following table lists the supported rack cabinets.
For specifications about these racks, see the Lenovo Rack Cabinet Reference, available from:
https://lenovopress.com/lp1287-lenovo-rack-cabinet-reference
For more information, see the list of Product Guides in the Rack cabinets category:
https://lenovopress.com/servers/options/racks
Power distribution units
The following table lists the power distribution units (PDUs) that are offered by Lenovo.
| Part number |
Feature code |
Description |
ANZ
|
ASEAN
|
Brazil
|
EET
|
MEA
|
RUCIS
|
WE
|
HTK
|
INDIA
|
JAPAN
|
LA
|
NA
|
PRC
|
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 0U Basic PDUs | |||||||||||||||
| 4PU7A93176 | C0QH | 0U 36 C13 and 6 C19 Basic 32A 1 Phase PDU v2 | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
| 4PU7A93169 | C0DA | 0U 36 C13 and 6 C19 Basic 32A 1 Phase PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
| 4PU7A93177 | C0QJ | 0U 24 C13/C15 and 24 C13/C15/C19 Basic 32A 3 Phase WYE PDU v2 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
| 4PU7A93170 | CBVF | 0U 24 C13/C15 and 24 C13/C15/C19 Basic 32A 3 Phase WYE PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
| 00YJ776 | ATZY | 0U 36 C13/6 C19 24A 1 Phase PDU | N | Y | Y | N | N | N | N | N | N | Y | Y | Y | N |
| 00YJ779 | ATZX | 0U 21 C13/12 C19 48A 3 Phase PDU | N | N | Y | N | N | N | Y | N | N | Y | Y | Y | N |
| 00YJ777 | ATZZ | 0U 36 C13/6 C19 32A 1 Phase PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | N | Y | Y |
| 00YJ778 | AU00 | 0U 21 C13/12 C19 32A 3 Phase PDU | Y | Y | N | Y | Y | Y | Y | Y | Y | N | N | Y | Y |
| 0U Switched and Monitored PDUs | |||||||||||||||
| 4PU7A93181 | C0QN | 0U 21 C13/C15 and 21 C13/C15/C19 Switched and Monitored 48A 3 Phase Delta PDU v2 (60A derated) | N | Y | N | N | N | N | N | Y | N | Y | N | Y | N |
| 4PU7A93174 | CBVJ | 0U 21 C13/C15 and 21 C13/C15/C19 Switched and Monitored 60A 3 Phase Delta PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
| 4PU7A93178 | C0QK | 0U 20 C13 and 4 C19 Switched and Monitored 32A 1 Phase PDU v2 | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
| 4PU7A93171 | C0D8 | 0U 20 C13 and 4 C19 Switched and Monitored 32A 1 Phase PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
| 4PU7A93182 | C0QP | 0U 18 C13/C15 and 18 C13/C15/C19 Switched and Monitored 63A 3 Phase WYE PDU v2 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
| 4PU7A93175 | C0CS | 0U 18 C13/C15 and 18 C13/C15/C19 Switched and Monitored 63A 3 Phase WYE PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
| 4PU7A93180 | C0QM | 0U 18 C13/C15 and 18 C13/C15/C19 Switched and Monitored 32A 3 Phase WYE PDU v2 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
| 4PU7A93173 | CBVH | 0U 18 C13/C15 and 18 C13/C15/C19 Switched and Monitored 32A 3 Phase WYE PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
| 4PU7A93179 | C0QL | 0U 16 C13/C15 and 16 C13/C15/C19 Switched and Monitored 24A 1 Phase PDU v2 (30A derated) | N | Y | N | N | N | N | N | Y | N | Y | N | Y | N |
| 4PU7A93172 | CBVG | 0U 16 C13/C15 and 16 C13/C15/C19 Switched and Monitored 30A 1 Phase PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
| 00YJ783 | AU04 | 0U 12 C13/12 C19 Switched and Monitored 48A 3 Phase PDU | N | N | Y | N | N | N | Y | N | N | Y | Y | Y | N |
| 00YJ781 | AU03 | 0U 20 C13/4 C19 Switched and Monitored 24A 1 Phase PDU | N | N | Y | N | Y | N | Y | N | N | Y | Y | Y | N |
| 00YJ782 | AU02 | 0U 18 C13/6 C19 Switched and Monitored 32A 3 Phase PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | N | Y |
| 00YJ780 | AU01 | 0U 20 C13/4 C19 Switched and Monitored 32A 1 Phase PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | N | Y |
| 1U Switched and Monitored PDUs | |||||||||||||||
| 4PU7A90808 | C0D4 | 1U 18 C19/C13 Switched and monitored 48A 3P WYE PDU V2 ETL | N | N | N | N | N | N | N | Y | N | Y | Y | Y | N |
| 4PU7A81117 | BNDV | 1U 18 C19/C13 switched and monitored 48A 3P WYE PDU - ETL | N | N | N | N | N | N | N | N | N | N | N | Y | N |
| 4PU7A90809 | C0DE | 1U 18 C19/C13 Switched and monitored 48A 3P WYE PDU V2 CE | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y |
| 4PU7A81118 | BNDW | 1U 18 C19/C13 switched and monitored 48A 3P WYE PDU – CE | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y |
| 4PU7A90810 | C0DD | 1U 18 C19/C13 Switched and monitored 80A 3P Delta PDU V2 | N | N | N | N | N | N | N | Y | N | Y | Y | Y | N |
| 4PU7A77467 | BLC4 | 1U 18 C19/C13 Switched and Monitored 80A 3P Delta PDU | N | N | N | N | N | N | N | N | N | Y | N | Y | N |
| 4PU7A90811 | C0DC | 1U 12 C19/C13 Switched and monitored 32A 3P WYE PDU V2 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
| 4PU7A77468 | BLC5 | 1U 12 C19/C13 switched and monitored 32A 3P WYE PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
| 4PU7A90812 | C0DB | 1U 12 C19/C13 Switched and monitored 60A 3P Delta PDU V2 | N | N | N | N | N | N | N | Y | N | Y | Y | Y | N |
| 4PU7A77469 | BLC6 | 1U 12 C19/C13 switched and monitored 60A 3P Delta PDU | N | N | N | N | N | N | N | N | N | N | N | Y | N |
| 46M4002 | 5896 | 1U 9 C19/3 C13 Switched and Monitored DPI PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
| 46M4004 | 5894 | 1U 12 C13 Switched and Monitored DPI PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
| 46M4003 | 5897 | 1U 9 C19/3 C13 Switched and Monitored 60A 3 Phase PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
| 46M4005 | 5895 | 1U 12 C13 Switched and Monitored 60A 3 Phase PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
| 1U C13 Enterprise PDUs (12x IEC 320 C13 outlets) | |||||||||||||||
| 39M2816 | 6030 | DPI C13 PDU+ | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
| 39Y8941 | 6010 | Enterprise C13 PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
| 1U C19 Enterprise PDUs (6x IEC 320 C19 outlets) | |||||||||||||||
| 39Y8948 | 6060 | Enterprise C19 PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
| 39Y8923 | 6061 | Enterprise C19 3 phase PDU (60a) | N | N | Y | N | N | N | Y | N | N | N | Y | Y | N |
| 1U Front-end PDUs (3x IEC 320 C19 outlets) | |||||||||||||||
| 39Y8938 | 6002 | DPI 30amp/125V Front-end PDU with NEMA L5-30P | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
| 39Y8939 | 6003 | DPI 30amp/250V Front-end PDU with NEMA L6-30P | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
| 39Y8934 | 6005 | DPI 32amp/250V Front-end PDU with IEC 309 2P+Gnd | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
| 39Y8940 | 6004 | DPI 60amp/250V Front-end PDU with IEC 309 2P+Gnd connector | Y | N | Y | Y | Y | Y | Y | N | N | Y | Y | Y | N |
| 39Y8935 | 6006 | DPI 63amp/250V Front-end PDU with IEC 309 2P+Gnd connector | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
| 1U NEMA PDUs (6x NEMA 5-15R outlets) | |||||||||||||||
| 39Y8905 | 5900 | DPI 100-127v PDU with Fixed Nema L5-15P line cord | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
| Line cords for 1U PDUs that ship without a line cord | |||||||||||||||
| 40K9611 | 6504 | 4.3m, 32A/380-415V, EPDU/IEC 309 3P+N+G 3ph wye (non-US) Line Cord | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
| 40K9612 | 6502 | 4.3m, 32A/230V, EPDU to IEC 309 P+N+G (non-US) Line Cord | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
| 40K9613 | 6503 | 4.3m, 63A/230V, EPDU to IEC 309 P+N+G (non-US) Line Cord | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
| 40K9614 | 6500 | 4.3m, 30A/208V, EPDU to NEMA L6-30P (US) Line Cord | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
| 40K9615 | 6501 | 4.3m, 60A/208V, EPDU to IEC 309 2P+G (US) Line Cord | N | N | Y | N | N | N | Y | N | N | Y | Y | Y | N |
| 40K9617 | 6505 | 4.3m, 32A/230V, Souriau UTG to AS/NZS 3112 (Aus/NZ) Line Cord | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
| 40K9618 | 6506 | 4.3m, 32A/250V, Souriau UTG Female to KSC 8305 (S. Korea) Line Cord | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
For more information, see the Lenovo Press documents in the PDU category:
https://lenovopress.com/servers/options/pdu
| Supported markets | Unsupported markets |
|---|---|
|
|
| Supported markets | Unsupported markets |
|---|---|
|
(None) |
| Supported markets | Unsupported markets |
|---|---|
|
|
| Supported markets | Unsupported markets |
|---|---|
|
(None) |
| Supported markets | Unsupported markets |
|---|---|
|
(None) |
| Supported markets | Unsupported markets |
|---|---|
|
(None) |
| Supported markets | Unsupported markets |
|---|---|
|
(None) |
| Supported markets | Unsupported markets |
|---|---|
|
(None) |
| Supported markets | Unsupported markets |
|---|---|
| (None) |
|
| Supported markets | Unsupported markets |
|---|---|
| (None) |
|
| Supported markets | Unsupported markets |
|---|---|
| (None) |
|
| Supported markets | Unsupported markets |
|---|---|
|
|
| Supported markets | Unsupported markets |
|---|---|
|
|
| Supported markets | Unsupported markets |
|---|---|
|
|
| Supported markets | Unsupported markets |
|---|---|
|
|
| Supported markets | Unsupported markets |
|---|---|
|
|
| Supported markets | Unsupported markets |
|---|---|
| (None) |
|
| Supported markets | Unsupported markets |
|---|---|
| (None) |
|
| Supported markets | Unsupported markets |
|---|---|
|
(None) |
| Supported markets | Unsupported markets |
|---|---|
|
(None) |
| Supported markets | Unsupported markets |
|---|---|
|
(None) |
| Supported markets | Unsupported markets |
|---|---|
|
(None) |
| Supported markets | Unsupported markets |
|---|---|
|
|
| Supported markets | Unsupported markets |
|---|---|
|
(None) |
| Supported markets | Unsupported markets |
|---|---|
|
(None) |
| Supported markets | Unsupported markets |
|---|---|
|
(None) |
| Supported markets | Unsupported markets |
|---|---|
|
|
| Supported markets | Unsupported markets |
|---|---|
|
(None) |
| Supported markets | Unsupported markets |
|---|---|
|
(None) |
| Supported markets | Unsupported markets |
|---|---|
|
(None) |
| Supported markets | Unsupported markets |
|---|---|
|
(None) |
| Supported markets | Unsupported markets |
|---|---|
|
(None) |
| Supported markets | Unsupported markets |
|---|---|
| (None) |
|
| Supported markets | Unsupported markets |
|---|---|
| (None) |
|
| Supported markets | Unsupported markets |
|---|---|
|
(None) |
| Supported markets | Unsupported markets |
|---|---|
|
(None) |
| Supported markets | Unsupported markets |
|---|---|
| (None) |
|
| Supported markets | Unsupported markets |
|---|---|
|
|
| Supported markets | Unsupported markets |
|---|---|
|
|
| Supported markets | Unsupported markets |
|---|---|
|
|
| Supported markets | Unsupported markets |
|---|---|
|
|
| Supported markets | Unsupported markets |
|---|---|
|
|
| Supported markets | Unsupported markets |
|---|---|
|
|
| Supported markets | Unsupported markets |
|---|---|
|
|
| Supported markets | Unsupported markets |
|---|---|
| (None) |
|
| Supported markets | Unsupported markets |
|---|---|
| (None) |
|
| Supported markets | Unsupported markets |
|---|---|
| (None) |
|
| Supported markets | Unsupported markets |
|---|---|
| (None) |
|
| Supported markets | Unsupported markets |
|---|---|
|
|
| Supported markets | Unsupported markets |
|---|---|
|
|
| Supported markets | Unsupported markets |
|---|---|
|
|
| Supported markets | Unsupported markets |
|---|---|
|
|
| Supported markets | Unsupported markets |
|---|---|
| (None) |
|
| Supported markets | Unsupported markets |
|---|---|
| (None) |
|
| Supported markets | Unsupported markets |
|---|---|
| (None) |
|
| Supported markets | Unsupported markets |
|---|---|
| (None) |
|
| Supported markets | Unsupported markets |
|---|---|
|
|
| Supported markets | Unsupported markets |
|---|---|
|
|
| Supported markets | Unsupported markets |
|---|---|
|
|
| Supported markets | Unsupported markets |
|---|---|
|
|
| Supported markets | Unsupported markets |
|---|---|
| (None) |
|
| Supported markets | Unsupported markets |
|---|---|
| (None) |
|
| Supported markets | Unsupported markets |
|---|---|
| (None) |
|
| Supported markets | Unsupported markets |
|---|---|
| (None) |
|
| Supported markets | Unsupported markets |
|---|---|
|
|
| Supported markets | Unsupported markets |
|---|---|
|
|
| Supported markets | Unsupported markets |
|---|---|
|
|
| Supported markets | Unsupported markets |
|---|---|
|
|
| Supported markets | Unsupported markets |
|---|---|
|
|
| Supported markets | Unsupported markets |
|---|---|
|
|
| Supported markets | Unsupported markets |
|---|---|
|
|
| Supported markets | Unsupported markets |
|---|---|
|
|
| Supported markets | Unsupported markets |
|---|---|
|
|
| Supported markets | Unsupported markets |
|---|---|
|
|
| Supported markets | Unsupported markets |
|---|---|
|
|
| Supported markets | Unsupported markets |
|---|---|
|
|
| Supported markets | Unsupported markets |
|---|---|
|
|
| Supported markets | Unsupported markets |
|---|---|
|
|
| Supported markets | Unsupported markets |
|---|---|
| (None) |
|
| Supported markets | Unsupported markets |
|---|---|
|
|
| Supported markets | Unsupported markets |
|---|---|
|
|
| Supported markets | Unsupported markets |
|---|---|
|
|
| Supported markets | Unsupported markets |
|---|---|
|
|
| Supported markets | Unsupported markets |
|---|---|
|
|
| Supported markets | Unsupported markets |
|---|---|
|
|
| Supported markets | Unsupported markets |
|---|---|
|
|
| Supported markets | Unsupported markets |
|---|---|
|
|
| Supported markets | Unsupported markets |
|---|---|
|
|
| Supported markets | Unsupported markets |
|---|---|
|
|
| Supported markets | Unsupported markets |
|---|---|
|
|
| Supported markets | Unsupported markets |
|---|---|
|
|
| Supported markets | Unsupported markets |
|---|---|
|
|
| Supported markets | Unsupported markets |
|---|---|
|
|
| Supported markets | Unsupported markets |
|---|---|
|
|
| Supported markets | Unsupported markets |
|---|---|
|
|
| Supported markets | Unsupported markets |
|---|---|
|
|
| Supported markets | Unsupported markets |
|---|---|
|
|
| Supported markets | Unsupported markets |
|---|---|
|
|
| Supported markets | Unsupported markets |
|---|---|
|
|
| Supported markets | Unsupported markets |
|---|---|
|
|
| Supported markets | Unsupported markets |
|---|---|
| (None) |
|
| Supported markets | Unsupported markets |
|---|---|
|
|
| Supported markets | Unsupported markets |
|---|---|
|
|
| Supported markets | Unsupported markets |
|---|---|
|
|
| Supported markets | Unsupported markets |
|---|---|
|
|
| Supported markets | Unsupported markets |
|---|---|
|
|
Uninterruptible power supply units
The following table lists the uninterruptible power supply (UPS) units that are offered by Lenovo.
† Only available in China and the Asia Pacific market.
For more information, see the list of Product Guides in the UPS category:
https://lenovopress.com/servers/options/ups
Lenovo Financial Services
Why wait to obtain the technology you need now? No payments for 90 days and predictable, low monthly payments make it easy to budget for your Lenovo solution.
- Flexible
Our in-depth knowledge of the products, services and various market segments allows us to offer greater flexibility in structures, documentation and end of lease options.
- 100% Solution Financing
Financing your entire solution including hardware, software, and services, ensures more predictability in your project planning with fixed, manageable payments and low monthly payments.
- Device as a Service (DaaS)
Leverage latest technology to advance your business. Customized solutions aligned to your needs. Flexibility to add equipment to support growth. Protect your technology with Lenovo's Premier Support service.
- 24/7 Asset management
Manage your financed solutions with electronic access to your lease documents, payment histories, invoices and asset information.
- Fair Market Value (FMV) and $1 Purchase Option Leases
Maximize your purchasing power with our lowest cost option. An FMV lease offers lower monthly payments than loans or lease-to-own financing. Think of an FMV lease as a rental. You have the flexibility at the end of the lease term to return the equipment, continue leasing it, or purchase it for the fair market value. In a $1 Out Purchase Option lease, you own the equipment. It is a good option when you are confident you will use the equipment for an extended period beyond the finance term. Both lease types have merits depending on your needs. We can help you determine which option will best meet your technological and budgetary goals.
Ask your Lenovo Financial Services representative about this promotion and how to submit a credit application. For the majority of credit applicants, we have enough information to deliver an instant decision and send a notification within minutes.
Seller training courses
The following sales training courses are offered for employees and partners (login required). Courses are listed in date order.
-
Partner Technical Webinar - ARS & DS Storage
2025-11-21 | 60 minutes | Employees and Partners
DetailsPartner Technical Webinar - ARS & DS Storage
In this 60-minute replay, Nadia Mosqueira, Sustainability Services Sr. Product Manager, guided us through ARS (Asset Recovery Services). Afterward, Roger Yarosh, Senior Product Manager for Storage, provided insights on the new DS storage.
Published: 2025-11-21
Tags: Data Management, Storage, Sustainability
Length: 60 minutes
Course code: NOV1425Start the training:
Employee link: Grow@Lenovo
Partner link: Lenovo 360 Learning Center
-
Lenovo ThinkSystem DS Series Overview
2025-11-14 | 20 minutes | Employees and Partners
DetailsLenovo ThinkSystem DS Series Overview
This course is designed to help you gain a comprehensive understanding of the Lenovo ThinkSystem DS Series. You will learn about its key functionalities and understand their importance and value for customers. By the end of this course, you will be equipped with the knowledge to effectively utilize the ThinkSystem DS Series.
Published: 2025-11-14
Tags: ThinkSystem, VMware
Length: 20 minutes
Course code: DSTOO103Start the training:
Employee link: Grow@Lenovo
Partner link: Lenovo 360 Learning Center
Related publications and links
For more information, see the following resources:
- Lenovo Data Center Unified Storage product page
https://www.lenovo.com/us/en/c/data-center/storage/unified-storage - Lenovo Data Center Solution Configurator
http://dcsc.lenovo.com - ThinkSystem DS Series Datasheet
https://lenovopress.lenovo.com/datasheet/ds0201-lenovo-thinksystem-ds-series-all-flash-array - ThinkSystem DS Interactive 3D Tour
https://lenovopress.lenovo.com/lp2333-3d-tour-ds-series-storage - ONTAP Ransomware Protection
https://datacentersupport.lenovo.com/us/en/storagepubs/ontap/ontap-security-hardening/autonomous-ransomware-protection - Lenovo Data Center Support - ThinkSystem DSxx00
https://datacentersupport.lenovo.com/us/en/products/storage/lenovo-storage/
Trademarks
Lenovo and the Lenovo logo are trademarks or registered trademarks of Lenovo in the United States, other countries, or both. A current list of Lenovo trademarks is available on the Web at https://www.lenovo.com/us/en/legal/copytrade/.
The following terms are trademarks of Lenovo in the United States, other countries, or both:
Lenovo®
ThinkAgile®
ThinkSystem®
XClarity®
The following terms are trademarks of other companies:
Linux® is the trademark of Linus Torvalds in the U.S. and other countries.
Microsoft®, Excel®, Georgia®, Internet Explorer®, Windows Server®, and Windows® are trademarks of Microsoft Corporation in the United States, other countries, or both.
IBM® is a trademark of IBM in the United States, other countries, or both.
Other company, product, or service names may be trademarks or service marks of others.
Configure and Buy
Full Change History
Changes in the November 19, 2025 update:
- Updated the - Seller training courses section
- Included new DS content
First published: November 11, 2025
Course Detail
Employees Only Content
The content in this document with a is only visible to employees who are logged in. Logon using your Lenovo ITcode and password via Lenovo single-signon (SSO).
The author of the document has determined that this content is classified as Lenovo Internal and should not be normally be made available to people who are not employees or contractors. This includes partners, customers, and competitors. The reasons may vary and you should reach out to the authors of the document for clarification, if needed. Be cautious about sharing this content with others as it may contain sensitive information.
Any visitor to the Lenovo Press web site who is not logged on will not be able to see this employee-only content. This content is excluded from search engine indexes and will not appear in any search results.
For all users, including logged-in employees, this employee-only content does not appear in the PDF version of this document.
This functionality is cookie based. The web site will normally remember your login state between browser sessions, however, if you clear cookies at the end of a session or work in an Incognito/Private browser window, then you will need to log in each time.
If you have any questions about this feature of the Lenovo Press web, please email David Watts at dwatts@lenovo.com.