Abstract
The System x3850 X6 server is a four-socket 4U rack-mounted server that represents the sixth generation of the Enterprise X-Architecture. It delivers fast application performance, is based on an agile system design, and is a resilient platform that is needed for mission-critical databases, enterprise applications, and virtualized environments.
The x3850 X6 packs numerous fault-tolerant and high-availability features into a high-density, 4U rack-optimized lid-less package that helps reduce the space that is needed to support massive network computing operations and simplify servicing. The x3850 X6 supports up to four Intel Xeon E7-4800/8800 v2 high-performance processors and up to 6 TB of memory.
Withdrawn from marketing: The System x3850 X6, machine type 3837 is withdrawn from marketing. The replacement is System x3850 X6, machine type 6241.
Change History
Changes in the August 25 update:
- Updated the internal drive options tables
System x3850 X6 video walk-through
Introduction
The System x3850 X6 server is a four-socket 4U rack-mounted server that represents the sixth generation of the Enterprise X-Architecture. It delivers fast application performance, is based on an agile system design, and is a resilient platform that is needed for mission-critical databases, enterprise applications, and virtualized environments.
The x3850 X6 packs numerous fault-tolerant and high-availability features into a high-density, 4U rack-optimized lid-less package that helps reduce the space that is needed to support massive network computing operations and simplify servicing. The x3850 X6 supports up to four Intel Xeon E7-4800/8800 v2 high-performance processors and up to 6 TB of memory.
Suggested use: Mission-critical scalable databases, business analytics, virtualization, enterprise applications, and cloud applications.
The following figure shows the System x3850 X6.
Figure 1. The System x3850 X6
Did you know?
The x3850 X6 server employs a lid-less design where all serviceable components are front- and rear-accessible. In addition, each major subsystem is implemented as modular "book" design, such as the Compute Books and I/O Books. This configuration means that components are easy to upgrade and service, which translates to greater uptime of applications to your users. The x3850 X6 offers enterprise scalability and advanced RAS features to support the most demanding mission-critical applications that require 24x7 operations.
Key features
The increasing demand for cloud-computing and analytics workloads by enterprises to meet social, mobile, and Big Data requirements drives innovation to find new ways to build informational systems. Clients are looking for cost-optimized fit-for-purpose IT solutions that manage large amounts of data, easily scale performance, and provide enterprise class reliability.
Built on decades of innovation, Lenovo introduces its sixth generation of Enterprise X-Architecture technology, the X6 servers. Lenovo X6 servers are fast, agile, and resilient:
- Fast application performance means immediate access to actionable information.
- Agile system design helps to reduce acquisition costs and provide the ability to upgrade processor and memory technology at each refresh within the same chassis.
- Resilient platforms maximize application uptime and promote easy integration in virtual environments.
Lenovo X6 servers continue to lead the way as the shift toward mission-critical scalable databases, business analytics, virtualization, enterprise applications, and cloud-computing applications accelerates.
Fast application performance
The server offer numerous features to boost performance:
- Supports memory-channel storage (eXFlash DIMMs), where solid-state storage devices are installed in memory DIMM sockets. These devices are directly connected to the processors and provide the lowest latency values in the industry.
- Based on the Intel Xeon processor E7-4800 v2 and E7-8800 v2 product family:
- Supports up to four E7-4800/8800 v2 processors with 60 cores and 120 threads to maximize the concurrent running of multi-threaded applications.
- Improves productivity by offering superior system performance with 15-core processors (up to 2.8 GHz core speeds), up to 37.5 MB of L3 cache, and up to three 8 GTps QPI interconnect links.
- Supports memory speeds up to 1600 MHz.
- Supports up to 96 DIMM sockets, with 24 DIMMs per processor.
- With eXFlash memory-channel storage, the server delivers up to 12.8 TB of ultra-low latency flash memory by using WriteNow technology, which is ideal for high-performance applications.
- Intelligent and adaptive system performance with Intel Turbo Boost Technology 2.0 allows processor cores to run at maximum speeds during peak workloads by temporarily going beyond processor thermal design power (TDP).
- Intel Hyper-Threading Technology boosts performance for multi-threaded applications by enabling simultaneous multi-threading within each processor core, up to two threads per core.
- Intel Virtualization Technology integrates hardware-level virtualization hooks that allow operating system vendors to better use the hardware for virtualization workloads.
- Intel Advanced Vector Extensions (AVX) improve floating-point performance for compute-intensive technical and scientific applications.
- Supports a 12 Gbps SAS RAID portfolio.
- The usage of solid-state drives (SSDs) instead of, or along with, traditional spinning drives (HDDs) can improve I/O performance. An SSD can support up to 100 times more I/O operations per second (IOPS) than a typical HDD.
- PCI Express 3.0 I/O adapter slots that improve the theoretical maximum bandwidth by almost 100% (8 GTps per link using 128b/130b encoding) compared to the previous generation of PCI Express 2.0 (5 GTps per link using 8b/10b encoding).
- With Intel Integrated I/O Technology, the PCI Express 3.0 controller is integrated into the Intel Xeon processor E7-4800/8800 v2 product families. This integration helps reduce I/O latency and increase overall system performance.
- Support for up to two graphics processing units (GPUs) and co-processors to maximize computing power.
- Energy-efficient electronic components help lower operational costs, including highly efficient 900 W AC and 1400 W AC power supplies with 80 PLUS Platinum certification.
Agile system design
The server provides many scalability and flexibility features:
- Innovative module "book" design for each of the three subsystems: Compute Books, Storage Book, and I/O Books. Front and rear access means that you can easily scale the system by adding components without removing the entire server from the rack.
- The modular book design also allows clients to create the configuration that fits their application and environment needs, which reduces acquisition costs while giving them the flexibility to grow and modify their configuration later.
- The book design also means that subsystem upgrades are simpler, quicker to perform, and have a lower impact on the rest of the server.
- Using 64 GB LRDIMMs, the server supports up to 6 TB of memory.
- Up to 32 eXFlash DIMMs are supported for a total of 12.8 TB of low-latency and high-performance storage.
- Up to 16x 1.8-inch eXFlash SSD bays, or up to eight 2.5-inch bays, provide a flexible and scalable all-in-one platform to meet your increasing demands.
- Offers up to 11 PCIe slots plus a dedicated Mezzanine LOM (ML2) adapter slot. Most slots are PCIe 3.0 to maximize I/O scalability.
- PCIe slots are implemented in I/O Books to maximize modularity. Choose from Half-length I/O Books or Full-length I/O Books, depending on the adapters that you need to deploy.
- Most components are common between the four-socket x3850 X6 and eight-socket x3950 X6, making for a simple upgrade path with minimal parts on the floor.
Resilient platform
The server provides many features to simplify serviceability and increase system uptime:
- Upward Integration Modules for standard hypervisors enable the creation and management of policies to maintain high availability of virtual machines and concurrent updating of the system firmware, with no impact on application performance or availability.
- Advanced Processor Recovery allows the system to automatically switch access and control of networking, management, and storage in the event of a processor 1 failure, providing higher availability and productivity.
- Advanced Page Retire proactively protects applications from corrupted pages in memory, which is crucial for scaling memory to terabytes.
- Redundant bit steering, memory mirroring, and memory rank sparing for redundancy in the event of a non-correctable memory failure.
- Intel Execute Disable Bit functionality can help prevent certain classes of malicious buffer overflow attacks when combined with a supported operating system.
- Intel Trusted Execution Technology provides enhanced security through hardware-based resistance to malicious software attacks, allowing an application to run in its own isolated space, which is protected from all other software running on a system.
- Redundant Intel Platform Controller Hub (PCH) connections to the processors allow the platform to maintain access to networking, storage, and server management during a processor failure.
- Hot-swap drives support RAID redundancy for data protection and greater system uptime.
- Hot-swap I/O Books enabling you to install or replace adapters while the server is still running.
- Tool-less lid-less design provides front and rear access for easy upgrades and serviceability. There is no need to pull the server out of the rack to access internal components.
- Hot-swap power supplies and hot-swap dual-motor redundant fans provide availability for mission-critical applications.
- A new LCD diagnostics panel that is combined with individual light path diagnostic LEDs quickly lead the technician to failed (or failing) components, which simplifies servicing, speeds up problem resolution, and helps improve system availability.
- Predictive Failure Analysis (PFA) detects when system components (processors, memory, HDDs, SSDs, fans, and power supplies) operate outside of standard thresholds and generates proactive alerts in advance of a possible failure, therefore increasing uptime.
- Built-in Integrated Management Module Version II (IMM2) continuously monitors system parameters, triggers alerts, and performs recovering actions in case of failures to minimize downtime.
- Includes a special Mezzanine LOM (ML2) adapter slot with support for adapters with either two 10 Gb ports or 4 Gb ports. Supports direct connectivity to the IMM2 service processor for out-of-band systems management.
- Integrated industry-standard Unified Extensible Firmware Interface (UEFI) enables improved setup, configuration, and updates, and simplifies error handling.
- Two integrated Trusted Platform Modules (TPMs) 1.2 support enables advanced cryptographic functionality, such as digital signatures and remote attestation.
- Industry-standard Advanced Encryption Standard (AES) NI support for faster and stronger encryption.
- IBM Systems Director® provides proactive systems management. It offers comprehensive systems management tools that help increase uptime, reduce costs, and improve productivity through advanced server management capabilities.
- Solid-state drives (SSDs) offer better reliability than traditional mechanical HDDs for greater uptime.
- Built-in diagnostic tests, using Dynamic Systems Analysis (DSA) Preboot, speed up troubleshooting tasks to reduce service time.
- Three-year customer-replaceable unit and onsite limited warranty, 9x5 next business day. Optional service upgrades are available.
Locations of key components and connectors
The following figure shows the front of the x3850 X6 server.
Figure 2. Front view of the System x3850 X6
The following figure shows the rear of the x3850 X6 server.
Figure 3. Rear view of the System x3850 X6
Standard specifications
The following table lists the standard specifications.
Components | Specification |
Machine type | 3837 |
Form factor | 4U rack. |
Processor | Up to four Intel Xeon E7-4800 v2 or E7-8800 v2 processors, each in a Compute Book. Each processor has either 15 cores (up to 2.8 GHz), 12 cores (up to 2.6 GHz), 10 cores (up to 2.2 GHz), eight cores (up to 2.0 GHz), or six cores (up to 3.4 GHz). There are three QPI links up to 8.0 GTps each. Up to 1600 MHz memory speed. Up to 37.5 MB L3 cache. Intel C602J chipset. |
Memory | Up to 96 DIMM sockets (24 DIMMs per processor, installed in the Compute Book). RDIMMs and LRDIMMs (Load Reduced DIMMs) are supported, but memory types cannot be intermixed. Memory speed up to 1600 MHz. |
Memory maximums | With RDIMMs: Up to 1.5 TB with 96x 16 GB RDIMMs and four processors. With LRDIMMs: Up to 6 TB with 96x 64 GB LRDIMMs and four processors. |
Memory protection | ECC, Chipkill, RBS, memory mirroring, and memory rank sparing. |
Memory-channel storage | eXFlash DIMMs are installed in memory DIMM slots, but are seen by the OS as storage devices. Memory channels with eXFlash DIMMs must also have at least one RDIMM. Cannot be mixed with LRDIMMs. A maximum of 32 eXFlash DIMMs can be installed. Maximum 12.8 TB with 32x 400GB eXFlash DIMMs. |
Disk drive bays | Up to sixteen 1.8-inch eXFlash SSD bays, or up to eight 2.5-inch hot-swap SAS/SATA bays. |
Maximum internal storage | Up to 14.4 TB with 1.8 TB 2.5-inch SAS HDDs, up to 12.8 TB with 1.6 TB 2.5-inch SAS SSDs, or up to 12.8 TB with 800 GB 1.8-inch SATA SSDs. |
RAID support | 12 Gb SAS/SATA RAID 0, 1, or 10 with ServeRAID M5210; optional upgrades to RAID 5 and 50 are available (zero-cache; 1 GB non-backed cache; 1 GB or 2 GB flash-backed cache). Upgrades to RAID 6 or 60 available for M5210 with 1 GB or 2 GB upgrades. |
Optical and tape bays | None. Supports external USB optical drives. |
Network interfaces | Mezzanine LOM (ML2) slot for dual-port 10 GbE cards with SFP+ or RJ-45 connectors or quad-port GbE cards with RJ-45 connectors. See Table 2. Dedicated 1 GbE port for systems management. |
PCI Expansion slots | Up to 11 PCIe slots plus dedicated Mezzanine LOM slot. The slots are as follows:
|
Ports | Front: Two USB 3.0, one USB 2.0, and one DB-15 video ports. Rear: Four USB 2.0, one DB-15 video, one DB-9 serial, and one 1 GbE RJ-45 systems management. Internal: USB 2.0 port for embedded hypervisor. |
Cooling | Calibrated Vectored Cooling™. Up to ten redundant hot-swap fan packs and five fan zones with N+1 fan redundancy. Each fan pack includes two counter-rotated dual-motor fans. |
Power supply | Up to four redundant hot-swap 900 W AC or 1400 W AC power supplies (all 80 PLUS Platinum certified). -48 V 750 W DC power supplies are available through CTO. Power supplies cannot be mixed. |
Hot-swap parts | Drives, power supplies, fans, and optional I/O Books. |
Video | Matrox G200eR2 with 16 MB memory that is integrated into the IMM2. Maximum resolution is 1600 x 1200 at 75 Hz with 16 M colors. |
Security features | Power-on password, admin password, and two Trusted Platform Modules (TPMs). |
Systems management | UEFI, Integrated Management Module II (IMM2) with remote presence feature, Predictive Failure Analysis, Light Path Diagnostics, Automatic Server Restart, IBM Systems Director and Active Energy Manager™, and ServerGuide. |
Operating systems supported | Microsoft Windows Server 2012 R2, 2012, and 2008 R2, Red Hat Enterprise Linux 6 and 7, SUSE Linux Enterprise Server 11 and 12, and VMware vSphere ESXi 5.1 and 5.5. |
Limited warranty | Three-year customer-replaceable unit (CRU) and onsite limited warranty with 9x5 next business day (NBD). |
Service and support | Optional service upgrades are available through ServicePac® offerings: 4-hour or 2-hour response time, 8-hour fix time, 1-year or 2-year warranty extension, and remote technical support for Lenovo hardware and some Lenovo / OEM applications. |
Dimensions | Height: 173 mm (6.8 in.), width: 482 mm (19.0 in.), depth: 804 mm (31.6 in), depth with cable management brackets installed: 836 mm (32.9 in), depth with Full-length I/O Book installed: 921 mm (36.2 in) |
Weight | Minimum configuration: 35.9 kg (79.2 lb), typical: 46.4 kg (102.3 lb), maximum: 54.7 kg (120 lb) |
The server is shipped with the following items:
- Rail kit
- Cable management brackets
- 2.8 m (9.18 ft) C13-C14 power cord (one for each power supply)
- Statement of Limited Warranty
- Important Notices
- Rack Installation Instructions
- Documentation CD that contains the Installation and Service Guide
- IBM Systems Director Flyer
Standard models
The following table lists the standard models.
Table 2. Standard models
Model† | Intel Xeon Processor* (in a Compute Book) |
Memory | eXFlash DIMMs |
RAID | Drive bays Drives |
Ethernet‡ | I/O slots§ |
Power supplies |
Standard x3850 X6 models | ||||||||
3837-A4x | 1x E7-4809 v2 6C 1.9GHz 12MB 105W |
2x 8GB (1333MHz)¤ |
Optional | Optional | Optional | 4x 1 GbE | 6 std 12 max |
1x 900W HS / 4 |
3837-B1x | 2x E7-4820 v2 8C 2.0GHz 16MB 105W |
4x 8GB 1600MHz |
Optional | 1x M5210 | 4x 2.5" HS / 8 Open bay |
4x 1 GbE | 6 std 12 max |
2x 900W HS / 4 |
3837-B3x | 2x E7-4850 v2 12C 2.3GHz 24MB 105W |
4x 8GB 1600MHz |
Optional | 1x M5210 | 4x 2.5" HS / 8 Open bay |
2x 10 GbE‡ | 6 std 12 max |
2x 900W HS / 4 |
3837-C1x | 2x E7-4860 v2 12C 2.6GHz 30MB 130W |
4x 8GB 1600MHz |
Optional | 1x M5210 | 4x 2.5" HS / 8 Open bay |
4x 1 GbE | 6 std 12 max |
2x 900W HS / 4 |
3837-C4x | 2x E7-4890 v2 15C 2.8GHz 37.5MB 155W |
4x 8GB 1600MHz |
Optional | 1x M5210 | 4x 2.5" HS / 8 Open bay |
4x 1 GbE | 6 std 12 max |
2x 900W HS / 4 |
† x in the Machine Type Model (MTM) represents a region-specific letter (for example, the EMEA MTM is 3837-A3G, and the US MTM is 3837-A4U). Ask a Lenovo representative for specifics.
* Processor detail: Processor quantity and model, cores, core speed, L3 cache, memory speed, and TDP.
¤ This model includes the DIMMs that are rated at 1600 MHz, but operate at up to 1333 MHz, as noted, to match the processor memory speed
‡ Model B3x includes the Broadcom NetXtreme II ML2 Dual Port 10GbE SFP+ adapter (BCM57810S based). All other models include Intel I350-T4 ML2 Quad Port GbE Adapter adapter (I350-AM4 based).
§ Models with six slots have the Primary I/O Book (four slots) and Storage Book (two slots) standard. Models with nine slots also include one Half-length I/O Book.
SAP HANA Workload Optimized Solution models
The System x3850 X6 Workload Optimized Solutions for SAP HANA provide optimal solutions for SAP NetWeaver Business Warehouse, data mart, and SAP Business Suite, Powered by SAP HANA applications. Preconfigured workload optimized server models for SAP HANA applications are configured with up to 1 TB of memory and are upgradeable to support larger single node and scale-out cluster implementations. These models include IBM General Parallel File System (GPFS) Single Server for x86 Integrated Offerings with 3-year software subscription and support.
The following table lists the Workload Optimized Solution models for SAP HANA.
Model | Intel Xeon Processor (in a Compute Book) |
Memory | RAID | Drive bays Drives |
Ethernet | I/O slots |
Power supplies |
3837- H2x |
2x E7-8880 v2 15C 2.5GHz 37.5MB 1600 MHz 130W |
128 GB 16x 8 GB RDIMM |
1x M5210 + upgrades* |
8x 2.5” HS 6x 1.2 TB SAS HDD 2x 400 GB S3700 SSD |
1x 4x1GbE ML2 2x Mellanox 10Gb* |
6 std 12 max |
4x 1400W HS / 4 |
3837- H3x |
2x E7-8880 v2 15C 2.5GHz 37.5MB 1600 MHz 130W |
256 GB 16x 16 GB RDIMM |
1x M5210 + upgrades* |
8x 2.5” HS 6x 1.2 TB SAS HDD 2x 400 GB S3700 SSD |
1x 4x1GbE ML2 2x Mellanox 10Gb* |
6 std 12 max |
4x 1400W HS / 4 |
3837- H4x |
2x E7-8880 v2 15C 2.5GHz 37.5MB 1600 MHz 130W |
512 GB 16x 32 GB LRDIMM |
1x M5210 + upgrades* |
8x 2.5” HS 6x 1.2 TB SAS HDD 2x 400 GB S3700 SSD |
1x 4x1GbE ML2 2x Mellanox 10Gb* |
6 std 12 max |
4x 1400W HS / 4 |
3837- H5x |
4x E7-8880 v2 15C 2.5GHz 37.5MB 1600 MHz 130W |
512 GB 32x 16 GB RDIMM |
1x M5210 + upgrades* |
8x 2.5” HS 6x 1.2 TB SAS HDD 2x 400 GB S3700 SSD |
1x 4x1GbE ML2 2x Mellanox 10Gb* |
12 std 12 max |
4x 1400W HS / 4 |
3837- H6x |
4x E7-8880 v2 15C 2.5GHz 37.5MB 1600 MHz 130W |
1024 GB 32x 32 GB LRDIMM |
1x M5210 + upgrades* 1x M5120 + upgrades* |
8x 2.5” HS 6x 1.2 TB SAS HDD 2x 400 GB S3700 SSD |
1x 4x1GbE ML2 2x Mellanox 10Gb* |
12 std 12 max |
4x 1400W HS / 4 |
* See the list of specific components below
Each of these HANA models include the following components
- ServeRAID M5210 controller (46C9110) with 2GB cache upgrade with flash backup (47C8664), plus Performance Accelerator (47C8710) and SSD Caching Enabler (47C8712)
- Model H6x only: ServeRAID M5120 RAID controller for external connectivity (81Y4478), with 1GB cache upgrade with flash backup (47C8660) plus Performance Accelerator (47C8710) and SSD Caching Enabler (47C8712).
- Six 1.2TB 10K 6Gbps SAS 2.5" G3HS HDD (00AJ146)
- Two S3700 400GB SATA 2.5" MLC G3HS Enterprise SSD for System x (00AJ161)
- One Intel I350-T4 ML2 Quad Port GbE Adapter for System x (00D1998)
- Two Mellanox ConnectX-3 40GbE / FDR IB VPI Adapters (00D9550)
- Four SFP+ SR Transceiver (46C3447)
- Four Mellanox QSA Adapter (QSFP to SFP+) (90Y3842)
- Model H5x, H6x only: Two X6 Half-length I/O Books (44X4049)
- Lenovo solution for SAP HANA media
- License for IBM General Parallel File System (GPFS) Single Server for x86 Integrated Offerings with 3-year software subscription and support
Note: the operating system software is not included with the SAP HANA models. Operating system selection must be a separate line item included in order: SLES for SAP with standard or priority support. The SAP HANA Software is included, but the license is sold separately by SAP or an SAP business partner. VMware Enterprise Plus license sold separately.
For more information about the standard features of the server, see the "Specifications" section.
Upgrading to an 8-socket system
The x3850 X6 server has a flexible modular design that allows you to increase the server’s compute power and I/O capabilities by adding additional Compute Books and I/O Books. The modular design also means that if your business needs additional processing or I/O capability within the same system image, then it is possible to migrate to an eight-socket x3950 X6.
Lenovo supports upgrading a 4-socket X6 server to an 8-socket X6 server. The two recommended methods are as follows:
- Start with a 4-socket x3950 X6 (8U chassis) and add additional processors when needed
- Start with a 4-socket x3850 X6 (4U chassis) and upgrade it when needed using an RPQ process
Option 1: Start with a 4-socket x3950 X6
With this option, you plan for the need for future 8-socket performance in advance and purchase an x3950 X6 with only four Compute Books installed. The initial order would contain:
- Four Compute Books with E7-8800 v2 series processors
- Four Power Supplies (preferably 1400W)
- Two Primary IO Book standard
- Two Storage Book Standard
Once the need arises to upgrade the server to six or eight processors, simply purchase more Compute Books with the same processor model, plus additional power supplies (as determined by using the Power Configurator), I/O Books, adapters and drives as needed.
For information about the x3950 X6, see the System x3950 X6 Product Guide:
http://lenovopress.com/tips1132
Option 2: Upgrade your 4-socket x3850 X6 using an RPQ
With this option, you don’t have to plan for 8-socket capacity up front. You start with an x3850 X6 then when you are ready to upgrade to a 6-socket or 8-socket server, you purchase an upgrade offering via an RPQ.
As part of the RPQ, a Lenovo service engineer comes onsite with the new mechanical chassis and performs the field upgrade by transferring all components to the new chassis. This method also requires the x3850 X6 compute books be the same E7-8800 v2 processors as ordered for the RPQ, however, in this scenario, the server maintain the original serial number.
Note: Use of E7-4800 v2 processors: Intel Xeon E7-4800 v2 processors cannot be used in an x3950 X6. If your x3850 X6 has Compute Books with E7-4800 v2 processors, then these must be replaced with Compute Books with E7-8800 v2 processors if you plan to upgrade to an x3950 X6. The memory in the Compute Books can be reused in the x3950 X6, however.
For this method, submit an RPQ for assessment and pricing. The existing x3850 X6 configuration will be evaluated and recommendations will be made based on the workload requirements.
The major parts of the 4U to 8U upgrade are the 8U chassis, the Storage Book and the Primary I/O Book. All the components in the package will be installed in the top portion of the chassis. The 4U system's components will be transferred to the bottom section of the chassis.
Even though this upgrade requires a new 8U chassis replacing the existing 4U chassis, the majority of internal components can be moved from the x3850 X6 to the x3950 X6.
The x3850 X6 components that can be migrated to the x3950 X6 as part of the RPQ upgrade are:
- Compute Books, provided they use Intel Xeon E7-8800 v2 processors
- All memory DIMMs
- Storage Book
- All internal drives
- Primary I/O Book (and associated fans)
- Half-length I/O Books
- Full-length I/O Books
- All adapters
- All power supplies
The RPQ upgrade includes these parts:
- New 8U chassis and 8-socket midplane
- A second Storage Book
- A second Primary I/O Book
The RPQ upgrade may also require new parts:
- Additional Compute Books (a minimum of four Compute Books required in the x3950 X6)
- Additional power supplies (a minimum of four are required in the x3950 X6)
- Additional I/O Books, network adapters, drives as needed
There are key considerations for this upgrade:
- Processor support: Intel Xeon E7-4800 v2 processors cannot be used in an x3950 X6. If your x3850 X6 has Compute Books with E7-4800 v2 processors, then these must be replaced with Compute Books with E7-8800 v2 processors if you plan to upgrade to an x3950 X6. The memory in the Compute Books can be reused in the x3950 X6, however.
- All processors must be identical: All processors used in the x3950 X6 must be the identical. For example, all E7-8850 v2 processors. A minimum of four processors are required.
- The upgrade does result in some parts no longer being used (“parts on the floor”):
- Existing 4U chassis and 4-socket midplane
- Compute Books that are based on E7-4800 v2 processors
- Original x3850 X6 server may need to be ordered configure-to-order (CTO) or Special Bid: To minimize “parts on the floor” (parts that cannot be used in the upgraded system), the original x3850 X6 should be configured with Compute Books containin E7-8800 v2 processors. Since many standard models of the x3850 X6 (see Table 2) contain E7-4800 v2 processors, you may need to use CTO (using a configurator such as x-config) or order the server using Special Bid to create a server configuration with E7-8800 v2 processors.
- Serial number swap: The RPQ upgrade process also involves transferring the x3850 X6 serial number to the x3950 X6 chassis. This transfer makes the upgrade simpler from an asset or depreciation management point of view. This transfer also means that the old 4U chassis will be retired as it will no longer have a valid serial number.
- Power supplies: Ideally all power supplies are the 1400W variant. Regardless of the selection, the power supplies coexistence rules as decribed in the Power supplies section must be followed.
- Additional power: Depending on your workload and configuration you may need to provision for additional PDU outlets, cables and power capacity for your x3950 X6 server. Use the Power Configurator to determine your total power draw to assist you in provisioning adequate power. You can download the Power Configurator from http://ibm.com/systems/bladecenter/resources/powerconfig.html
- Additional rack space: An additional 4U of rack space is required when upgrading the x3850 X6 to the x3950 X6, for a total of 8U of rack space.
- Down time: In order to upgrade the x3850 X6 server to a x3950 X6 server you will need to allow for down time. The server will need to be completely powered off and have some of its components removed for re-installation into the new x3950 X6 server.
Processor options
The x3850 X6 supports up to four Intel Xeon E7 v2 processors. Processors are installed in Compute Books, one processor in each Compute Book. The following figure shows the components of the Compute Book:
- One processor
- A total of 24 DIMM slots, 12 on each side of the book
- Two hot-swap dual-motor fans that are mounted on the front of the book
The x3850 X6 supports two or four Compute Books. Three Compute Books are not supported. A configuration of one Compute Book is only supported in standard model 3837-A4x.
Each Compute Book is installed in the front of the server, as shown in the following figure.
Figure 4. Compute Book
The following table shows the processor options. Each option includes the processor installed in a Compute Book. Compute Books with one of the E7-4800 family of processors are supported only in a four-socket x3850 X6 server and cannot be used in an x3950 X6 server.
The table also shows the maximum memory bus speed each processor supports plus which server models have each processor standard. If there is no corresponding where-used model for a particular processor, this processor is only available through CTO.
Part number | Feature code | Description (processor installed in a Compute Book) |
Memory bus speed (RAS / Performance)† |
Supported quantities x3850 X6* |
x3850 X6 models where used |
Intel Xeon E7-4800 v2 processor family (not supported in the x3950 X6) | |||||
44X3961 | A4B3 | X6 Compute Book Intel Xeon E7-4809 v2 6C 1.9GHz 105W | 1333 / 1066 MHz | 2, 4 | A4x |
44X3966 | A4B4 | X6 Compute Book Intel Xeon E7-4820 v2 8C 2.0GHz 105W | 1600 / 1066 MHz | 2, 4 | B1x |
44X3971 | A4B5 | X6 Compute Book Intel Xeon E7-4830 v2 10C 2.2GHz 105W | 1600 / 1066 MHz | 2, 4 | - |
44X3976 | A4B6 | X6 Compute Book Intel Xeon E7-4850 v2 12C 2.3GHz 105W | 1600 / 1066 MHz | 2, 4 | B3x |
44X3981 | A4B7 | X6 Compute Book Intel Xeon E7-4860 v2 12C 2.6GHz 130W | 1600 / 1333 MHz | 2, 4 | C1x |
44X3986 | A4B8 | X6 Compute Book Intel Xeon E7-4870 v2 15C 2.3GHz 130W | 1600 / 1333 MHz | 2, 4 | - |
44X3991 | A4B9 | X6 Compute Book Intel Xeon E7-4880 v2 15C 2.5GHz 130W | 1600 / 1333 MHz | 2, 4 | - |
44X3996 | A4BA | X6 Compute Book Intel Xeon E7-4890 v2 15C 2.8GHz 155W | 1600 / 1333 MHz | 2, 4 | C4x |
Intel Xeon E7-8800 v2 processor family (also supported in the x3950 X6) | |||||
44X4001 | A4BB | X6 Compute Book Intel Xeon E7-8850 v2 12C 2.3GHz 105W | 1600 / 1066 MHz | 2, 4 | - |
44X4031 | A4BH | X6 Compute Book Intel Xeon E7-8857 v2 12C 3.0GHz 130W | 1600 / 1333 MHz | 2, 4 | - |
44X4011 | A4BD | X6 Compute Book Intel Xeon E7-8870 v2 15C 2.3GHz 130W | 1600 / 1333 MHz | 2, 4 | - |
44X4016 | A4BE | X6 Compute Book Intel Xeon E7-8880 v2 15C 2.5GHz 130W | 1600 / 1333 MHz | 2, 4 | - |
44X4036 | A4BJ | X6 Compute Book Intel Xeon E7-8880L v2 15C 2.2GHz 105W | 1600 / 1333 MHz | 2, 4 | - |
44X4021 | A4BF | X6 Compute Book Intel Xeon E7-8890 v2 15C 2.8GHz 155W | 1600 / 1333 MHz | 2, 4 | - |
44X4026 | A4BG | X6 Compute Book Intel Xeon E7-8891 v2 10C 3.2GHz 155W | 1600 / 1333 MHz | 2, 4 | - |
44X4006 | A4BC | X6 Compute Book Intel Xeon E7-8893 v2 6C 3.4GHz 155W | 1600 / 1333 MHz | 2, 4 | - |
† The processors support two memory modes, RAS mode (also known as lockstep mode) and Performance mode (also known as independent mode). In Performance mode, the SMI2 link operates at twice the memory bus speed shown.
* A configuration of one processor is only supported in model 3837-A4x. No other server model or CTO configuration supports one processor.
Memory options
Lenovo DDR3 memory is compatibility tested and tuned for optimal System x® performance and throughput. Lenovo memory specifications are integrated into the light path diagnostics for immediate system performance feedback and optimum system uptime. From a service and support standpoint, Lenovo memory automatically assumes the system warranty, and Lenovo provides service and support worldwide.
The x3850 X6 supports DDR3 memory operating at speeds up to 1600 MHz. The x3850 X6 supports up to 96 DIMMs when all processors are installed, 24 DIMMs per processor. Each processor has four memory channels that are implemented using Scalable Memory Interface generation 2 (SMI2) chips, and the server implements three DIMMs per channel. The processor and the corresponding memory DIMM slots are on the Compute Book.
The following table lists the memory options that are available for x3850 X6.
Table 5. Memory options
Part number | Feature code | Description | Maximum supported x3850 X6 |
Models where used |
RDIMMs | ||||
00D5024 | A3QE | 4GB (1x4GB, 1Rx4, 1.35V) PC3L-12800 CL11 ECC DDR3 1600MHz LP RDIMM |
96 (24 per CPU) | - |
00D5036 | A3QH | 8GB (1x8GB, 1Rx4, 1.35V) PC3L-12800 CL11 ECC DDR3 1600MHz LP RDIMM |
96 (24 per CPU) | A4x, B1x, B3x, C1x, C4x, |
46W0672 | A3QM | 16GB (1x16GB, 2Rx4, 1.35V) PC3L-12800 CL11 ECC DDR3 1600MHz LP RDIMM |
96 (24 per CPU) | - |
LRDIMMs | ||||
46W0676 | A3SR | 32GB (1x32GB, 4Rx4, 1.35V) PC3L-12800 CL11 ECC DDR3 1600MHz LP LRDIMM |
96 (24 per CPU) | - |
46W0741 | A451 | 64GB (1x64GB, 8Rx4, 1.35V) PC3-10600 DDR3 1333MHz LP LRDIMM |
96 (24 per CPU) | - |
The following rules apply when selecting the memory configuration:
- The server supports RDIMMs and LRDIMMs.
- Mixing different types of memory (RDIMMs and LRDIMMs) is not supported.
- The maximum number of ranks per one DDR3 channel is six with RDIMMs or 24 with LRDIMMs.
- In RAS (lockstep) mode, DIMMs must be installed in a pair.
- The maximum quantity of DIMMs that can be installed in the server depends on the number of processors, DIMM type, rank, and operating voltage, as shown in the "Maximum qty supported" row in the following table.
- All DIMMs in the server operate at the same speed, which is determined as the lowest value of one of the following options:
- Memory speed that is supported by the specific processor.
- Lowest of maximum operating speeds for selected memory configuration that depends on rated speed, operating voltage, and quantity of DIMMs per channel, as shown under "Maximum operating speed" section in the following table.
- The server also supports eXFlash DIMMs, which are also installed in the DIMM slots. The "eXFlash memory-channel storage" section describes these eXFlash DIMMs and the configuration rules.
The following table shows the characteristics of the supported DIMMs. Tables cells that are highlighted with a gray background indicate that the server supports higher memory frequencies or larger memory capacity (or both) than the Intel processor specification defines.
Memory speed: In performance mode, memory channels operate independently, and the SMI2 link operates at twice the DDR3 speed. In RAS mode, two channels operate synchronously, and the SMI2 link operates at the DDR3 speed.
DIMM specification |
RDIMM
|
LRDIMM
|
||||||
Rank | Single rank | Dual rank | Quad rank | 8-rank | ||||
Part numbers | 00D5024 (4GB) 00D5036 (8GB) |
46W0672 (16GB) | 46W0676 (32GB) | 46W0741 (64GB) | ||||
Rated speed | 1600 MHz | 1600 MHz | 1600 MHz | 1333 MHz | ||||
Rated voltage | 1.35 V | 1.35 V | 1.35 V | 1.35 V | ||||
Operating voltage | 1.35 V | 1.5 V | 1.35 V | 1.5 V | 1.35 V | 1.5 V | 1.35 V | 1.5 V |
Max qty supported* | 96 | 96 | 96 | 96 | 96 | 96 | 96 | 96 |
Max DIMM capacity | 8 GB | 8 GB | 16 GB | 16 GB | 32 GB | 32 GB | 64 GB | 64 GB |
Max memory capacity | 0.75 TB | 0.75 TB | 1.5 TB | 1.5 TB | 3 TB | 3 TB | 6 TB | 6 TB |
Maximum operating speed - Performance mode (2:1 mode - SMI2 link operates at twice the DDR3 speed shown) | ||||||||
1 DIMM per channel | 1333 MHz | 1333 MHz | 1333 MHz | 1333 MHz | 1333 MHz | 1333 MHz | 1333 MHz | 1333 MHz |
2 DIMMs per channel | 1333 MHz | 1333 MHz | 1333 MHz | 1333 MHz | 1333 MHz | 1333 MHz | 1333 MHz | 1333 MHz |
3 DIMMs per channel | 1066 MHz | 1333 MHz | 1066 MHz | 1333 MHz | 1333 MHz | 1333 MHz | 1333 MHz | 1333 MHz |
Maximum operating speed - RAS mode (1:1 mode - SMI2 link operates at the DDR3 speed shown) | ||||||||
1 DIMM per channel | 1333 MHz | 1600 MHz | 1333 MHz | 1600 MHz | 1333 MHz | 1600 MHz | 1333 MHz | 1333 MHz |
2 DIMMs per channel | 1333 MHz | 1600 MHz | 1333 MHz | 1600 MHz | 1333 MHz | 1600 MHz | 1333 MHz | 1333 MHz |
3 DIMMs per channel | 1066 MHz | 1333 MHz | 1066 MHz | 1333 MHz | 1333 MHz | 1333 MHz | 1333 MHz | 1333 MHz |
* Maximum quantity supported is shown for all processors that are installed.
The following memory protection technologies are supported:
- ECC
- Chipkill (for x4-based memory DIMMs)
- Redundant bit steering (Double Device Data Correction)
- Memory mirroring
- Memory rank sparing
Chipkill and Redundant Bit Steering are supported in RAS mode. Chipkill is supported in Performance mode.
If memory mirroring is used, DIMMs must be installed in pairs for Performance mode (minimum of one pair per each processor) and quads for RAS mode. DIMMs in the pair/quad must be identical in type and size.
If memory rank sparing is used, then a minimum of two single-rank or dual-rank DIMMs must be installed per populated channel (the DIMMs do not need being identical). In rank sparing mode, one rank of a DIMM in each populated channel is reserved as spare memory. The size of a rank varies depending on the DIMMs that are installed.
eXFlash memory-channel storage
eXFlash memory-channel storage are storage offerings in the physical form of memory DIMMs. These eXFlash DIMMs are installed in memory DIMM sockets but appear to the operating system and applications as block storage devices. This new and innovative technology brings storage electrically closer to the processor subsystem, therefore improving performance considerably.
Withdrawn: Memory-channel storage is now withdrawn from marketing.
The following table shows the supported eXFlash DIMMs.
Table 7. Internal storage expansion options
Part number | Feature code |
Name and description | Maximum supported |
00FE000 | A4GX | eXFlash 200GB DDR3 Storage DIMM | 32 |
00FE005 | A4GY | eXFlash 400GB DDR3 Storage DIMM | 32 |
The following figure shows one eXFlash DIMM installed with RDIMMs in the Compute Book.
Figure 5. eXFlash DIMM installed in the Compute Book
The following rules apply when building a server configuration with eXFlash DIMMs:
- The 200 GB and 400 GB eXFlash DIMMs cannot be mixed.
- Performance memory mode must be selected. RAS (lockstep) memory mode is not supported.
- Only RDIMMs are supported by eXFlash DIMMs; LRDIMMs are not supported
- The maximum quantities of eXFlash DIMMs are as follows:
- One processor: 8 eXFlash DIMMs
- Two processors: 16 eXFlash DIMMs
- Four processors: 32 eXFlash DIMMs
For more information, visit the eXFlash DIMM support page:
http://ibm.com/support/entry/portal/docdisplay?lndocid=SERV-FLASHDM
Internal storage
The server supports 1.8-inch solid-state drives in the eXFlash SSD units and 2.5-inch SSDs and HDDs. Drives are installed in the Storage Book. The x3850 X6 has one Storage Book. The Storage Book supports the following configurations:
- 4x 2.5-inch hot-swap drive bays
- 8x 2.5-inch hot-swap drive bays
- 4x 2.5-inch hot-swap drive bays + 8x 1.8-inch hot-swap SSD bays
- 8x 1.8-inch hot-swap SSD bays
- 16x 1.8-inch hot-swap SSD bays
The following figure shows these configurations.
Figure 6. Internal drive configurations
Backplanes
All standard models ship with four 2.5-inch SAS/SATA hot-swap hard disk drive bays. The following table shows the internal storage expansion options that are available.
Table 8. Internal storage expansion options
Part number |
Feature code |
Description | Maximum supported x3850 X6 |
44X4104 | A4A6 | 4x 2.5" HS 12Gb SAS HDD Backplane | 2 |
44X4106 | A4A7 | 8x 1.8" HS 12Gb SAS HDD Backplane | 2 |
The backplanes are connected to one or two RAID controllers or HBAs depending on the number and type of backplane that is installed. The adapters are installed in PCIe slots in the Storage Book, as shown in the following figure.
Figure 7. Storage Book
The following table shows the backplanes that are required per Storage Book and the number of controllers that are required. Note that the table shows the exact number of controllers supported for each drive/backplane configuration, no more, no fewer.
Table 9. Drive combinations per Storage Book
Drive combination | Backplanes required | Number of controllers supported |
4x 2.5-inch hot-swap drive bays | 1x 4x 2.5" HS 12Gb SAS HDD Backplane, 44X4104 | 1 |
8x 2.5-inch hot-swap drive bays | 2x 4x 2.5" HS 12Gb SAS HDD Backplane, 44X4104 | 1 |
4x 2.5-inch hot-swap drive bays + 8x 1.8-inch hot-swap SSD bays |
1x 4x 2.5" HS 12Gb SAS HDD Backplane, 44X4104 1x 8x 1.8" HS 12Gb SAS HDD Backplane, 44X4106 |
2 |
8x 1.8-inch hot-swap SSD bays | 1x 8x 1.8" HS 12Gb SAS HDD Backplane, 44X4106 | 1 |
16x 1.8-inch hot-swap SSD bays | 2x 8x 1.8" HS 12Gb SAS HDD Backplane, 44X4106 | 2 |
Controllers for internal storage
The following table lists the RAID controllers, HBAs, and additional hardware and feature upgrades that are used for internal disk storage. The adapters are installed in slots in the Storage Book.
Part number | Feature code | Description | Maximum supported x3850 X6 |
Where used |
46C9110 | A3YZ | ServeRAID M5210 SAS/SATA Controller | 2 | All models |
47C8675 | A3YY | N2215 SAS/SATA HBA for System x | 2 | - |
Hardware upgrades for the M5210 | ||||
47C8656 | A3Z0 | ServeRAID M5200 Series 1GB Cache/RAID 5 Upgrade | 2 | - |
47C8660 | A3Z1 | ServeRAID M5200 Series 1GB Flash/RAID 5 Upgrade | 2 | - |
47C8664 | A3Z2 | ServeRAID M5200 Series 2GB Flash/RAID 5 Upgrade | 2 | - |
47C8668 | A3Z3 | ServeRAID M5200 Series 4GB Flash/RAID 5 Upgrade | 2 | - |
Features on Demand upgrades for the M5210 | ||||
47C8708 | A3Z6 | ServeRAID M5200 Series Zero Cache/RAID 5 Upgrade | 1 | - |
47C8706 | A3Z5 | ServeRAID M5200 Series RAID 6 Upgrade | 1* | - |
47C8710 | A3Z7 | ServeRAID M5200 Series Performance Accelerator | 1* | - |
47C8712 | A3Z8 | ServeRAID M5200 Series SSD Caching Enabler | 1* | - |
* These M5210 features upgrades require a cache memory upgrade (47C8656, 47C8660, or 47C8664).
The ServeRAID M5210 SAS/SATA Controller has the following specifications:
- Eight internal 12 Gbps SAS/SATA ports
- Two x4 HD mini-SAS internal connectors (SFF-8643)
- Supports connections to SAS/SATA drives and SAS Expanders
- Supports RAID 0, 1, and 10
- Supports RAID 5 and 50 with optional M5200 Series RAID 5 upgrades
- Supports RAID 6 and 60 with the optional M5200 Series RAID 6 Upgrade
- Supports 1 GB non-backed cache or 1 GB or 2 GB flash-backed cache
- Up to 12 Gbps throughput per port
- PCIe 3.0 x8 host interface
- Based on the LSI SAS3108 12 Gbps ROC controller
The N2215 SAS/SATA HBA has the following specifications:
- Eight internal 12 Gbps SAS/SATA ports
- Two x4 HD mini-SAS internal connectors (SFF-8643)
- Supports connections to SAS/SATA HDDs and SATA SSDs
- Optimized for SSD performance
- No RAID support
- Up to 12 Gbps throughput per port
- PCIe 3.0 x8 host interface
- Based on the LSI SAS3008 12 Gbps controller
For more information, see the list of Lenovo Press Product Guides in the RAID adapters category at the following address:
http://lenovopress.com/systemx/raid
Internal drive options
The following tables lists hard disk drive options for internal storage.
Part number | Feature | Description | Maximum supported |
---|---|---|---|
1.8-inch hot-swap SSDs - 6 Gb SATA - Enterprise Mainstream (3-5 DWPD) | |||
00AJ335 | A56V | 120GB SATA 1.8" MLC Enterprise Value SSD | 16 |
00AJ340 | A56W | 240GB SATA 1.8" MLC Enterprise Value SSD | 16 |
00AJ345 | A56X | 480GB SATA 1.8" MLC Enterprise Value SSD | 16 |
00AJ350 | A56Y | 800GB SATA 1.8" MLC Enterprise Value SSD | 16 |
Part number | Feature | Description | Maximum supported |
---|---|---|---|
2.5-inch hot-swap HDDs - 12 Gb SAS 10K | |||
00NA251 | ASBH | 900GB 10K 12Gbps SAS 2.5" G3HS 512e HDD | 8 |
00NA241 | ASBF | 600GB 10K 12Gbps SAS 2.5" G3HS 512e HDD | 8 |
00NA261 | ASBK | 1.2TB 10K 12Gbps SAS 2.5" G3HS 512e HDD | 8 |
00NA271 | ASBM | 1.8TB 10K 12Gbps SAS 2.5" G3HS 512e HDD | 8 |
2.5-inch hot-swap HDDs - 12 Gb SAS 15K | |||
00NA221 | ASBB | 300GB 15K 12Gbps SAS 2.5" G3HS 512e HDD | 8 |
00NA231 | ASBD | 600GB 15K 12Gbps SAS 2.5" G3HS 512e HDD | 8 |
2.5-inch hot-swap SED HDDs - 12 Gb SAS 10K | |||
00NA301 | ASBT | 1.2TB 10K 12Gbps SAS 2.5" G3HS 512e SED | 8 |
Part number | Feature | Description | Maximum supported |
---|---|---|---|
2.5-inch hot-swap HDDs - 6 Gb SAS 15K | |||
00AJ111 | A4TQ | 146GB 15K 6Gbps SAS 2.5" G3HS HDD | 8 |
2.5-inch hot-swap HDDs - 6 Gb NL SAS | |||
00AJ121 | A4TT | 500GB 7.2K 6Gbps NL SAS 2.5" G3HS HDD | 8 |
2.5-inch hot-swap HDDs - 6 Gb NL SATA | |||
00AJ136 | A4TW | 500GB 7.2K 6Gbps NL SATA 2.5" G3HS HDD | 8 |
00AJ141 | A4TX | 1TB 7.2K 6Gbps NL SATA 2.5" G3HS HDD | 8 |
Part number | Feature | Description | Maximum supported |
---|---|---|---|
2.5-inch hot-swap SSDs - 12 Gb SAS - Enterprise Performance (10+ DWPD) | |||
00FN379 | AS7C | 200GB 12G SAS 2.5" MLC G3HS Enterprise SSD | 8 |
00FN389 | AS7E | 400GB 12G SAS 2.5" MLC G3HS Enterprise SSD | 8 |
00FN399 | AS7G | 800GB 12G SAS 2.5" MLC G3HS Enterprise SSD | 8 |
00FN409 | AS7J | 1.6TB 12G SAS 2.5" MLC G3HS Enterprise SSD | 8 |
Part number | Feature | Description | Maximum supported |
---|---|---|---|
2.5-inch hot-swap SSDs - 6 Gb SAS - Enterprise Capacity | |||
00NA671 | ASW6 | 3.84TB 6Gb SAS Enterprise Capacity G3HS MLC SSD | 8 |
2.5-inch hot-swap SSDs - 6 Gb SAS - Enterprise Performance (10+ DWPD) | |||
00AJ207 | A4UA | 200GB SAS 2.5" MLC G3HS Enterprise SSD | 8 |
00AJ212 | A4UB | 400GB SAS 2.5" MLC G3HS Enterprise SSD | 8 |
00AJ217 | A4UC | 800GB SAS 2.5" MLC G3HS Enterprise SSD | 8 |
2.5-inch hot-swap SSDs - 6 Gb SATA - Enterprise Mainstream (3-5 DWPD) | |||
00AJ395 | A577 | 120GB SATA 2.5" MLC G3HS Enterprise Value SSD | 8 |
00AJ400 | A578 | 240GB SATA 2.5" MLC G3HS Enterprise Value SSD | 8 |
00AJ405 | A579 | 480GB SATA 2.5" MLC G3HS Enterprise Value SSD | 8 |
00AJ410 | A57A | 800GB SATA 2.5" MLC G3HS Enterprise Value SSD | 8 |
Internal backup units
The server does not support internal tape drive options.
Optical drives
The server does not support internal optical drives.
I/O expansion options
The server supports up to 11 PCIe slots plus dedicated Mezzanine LOM slot (12 total) as follows:
- In the Storage Book (standard in all models): Two PCIe 3.0 x8 slots for supported internal RAID controllers and SAS HBAs
- In the Primary I/O Book (standard in all models):
- Two PCIe 3.0 x16 slots (x16-wired), half length, full height, up to 75 W of power
- One PCIe 3.0 x16 (x8-wired), half length, full height, up to 75 W of power
- One mezzanine LOM 2 (ML2) slot for network adapters with the new ML2 form factor (PCIe 3.0 x8)
- Two optional I/O Books, each with three slots, all full height. Optional I/O Books are enabled for hot-swap.
The following figure shows the Primary I/O Book with the air baffle raised to show the internals.
Figure 8. Primary I/O Book
Optional I/O Books can be either of:
- Half-length I/O Book:
- Two PCIe 3.0 x8 slots (x8 wired)
- One PCIe 3.0 x16 slot (x16 wired)
- Full-length I/O Book:
- Two PCIe 3.0 x16 (x16 wired)
- One PCIe 2.0 x8 slot (x4 wired)
In order for an I/O Book to be hot-swappable, all adapters that are installed in the book must support hot-swap and the operating system must also support hot-swap. These operating systems support hot-swap:
- Windows Server 2008 R2
- Windows Server 2012
- Windows Server 2012 R2
The adapters listed in the following table support hot-swap.
Part number | Feature code | Description |
00D8540* | A4XH | Emulex Dual Port 10GbE SFP+ VFA IIIr for System x* |
49Y7960 | A2EC | Intel X520 Dual Port 10GbE SFP+ Adapter for System x |
49Y7970 | A2ED | Intel X540-T2 Dual Port 10GBaseT Adapter for System x |
49Y4230 | 5767 | Intel Ethernet Dual Port Server Adapter I340-T2 for System x |
49Y4240 | 5768 | Intel Ethernet Quad Port Server Adapter I340-T4 for System x |
00AG500 | A56K | Intel I350-F1 1xGbE Fiber Adapter for System x |
00AG510 | A56L | Intel I350-T2 2xGbE BaseT Adapter for System x |
00AG520 | A56M | Intel I350-T4 4xGbE BaseT Adapter for System x |
* Hot-swap is only supported when the adapter is in pNIC mode. Hot-swap is not supported in either vNIC mode (Virtual Fabric mode or Switch Independent mode).
The usage of these Optional I/O Books requires all four processors to be installed.
The following table shows the ordering information for the optional I/O Books.
Table 17. I/O Book options
Part number |
Feature code |
Description | Maximum supported x3850 X6 |
44X4049 | A4A2 | X6 Half-Length I/O Book | 2 |
44X4051 | A4A3* | X6 Full-Length I/O Book | 2 |
* The Full-length I/O Book can be ordered only as an option. It is not available through CTO because the Full-length I/O Book cannot be shipped installed in the server
The following figure shows the two optional I/O Books, the Half-length I/O Book and the Full-length I/O Book.
Figure 9. Half-length I/O Book and the Full-length I/O Book
The following figure shows the inside of the Half-length I/O Book.
Figure 10. Half-length I/O Book
Each slot in the Half-length I/O Book and the Full-length I/O Book supplies up to 75 W of power.
The Full-length I/O Book also includes two auxiliary power connectors. With the use of these connectors and the supplied power cords, the I/O book supports one double-wide adapter up to 300 W. The auxiliary power connectors are as follows:
- One 2x4 power connector, which supplies up to 150 W of additional power to the adapter
- One 2x3 power connector, which supplies up to 75 W of additional power to the adapter
The combined power consumption of all the adapters that are installed in the Full-length I/O Book cannot exceed 300 W.
Note: The 2x3 connector is intended to be used only when one adapter is installed in the first x16 slot (the up-most slot in the following figure), either requiring 225 W or 300 W of power. The location of the 2x3 connector prevents an adapter from being installed in the other x16 slot.
Figure 11. Full-length I/O Book
The Half-length I/O Book installs flush with the Primary I/O Book at the rear of the server. The Full-length I/O Book, when installed, adds a 99 mm (3.9 in.) mechanical extension to the base length dimension of the chassis.
The following figure shows a Full-length I/O Book and a Half-length I/O Book installed in the server.
Figure 12. I/O Books that are installed in the x3850 X6
Network adapters
The server supports ML2 adapters that are installed in the custom ML2 slot. This slot supports adapters with either two 10 Gb ports or four Gigabit ports and supports direct connectivity to the IMM2 service processor for out-of-band systems management.
As listed in Table 2, Model B3x includes the Broadcom NetXtreme II ML2 Dual Port 10GbE SFP+ adapter as standard. All other standard models include an Intel I350-T4 ML2 Quad Port GbE Adapter (I350-AM4 based).
The Broadcom NetXtreme II ML2 Dual Port 10GbE SFP+ Adapter has the following specifications:
- Dual-port 10 Gb Ethernet connectivity
- Broadcom BCM57810S ASIC
- SFP+ ports supporting fiber optic and direct-attach copper (DAC) cables
For more information about this adapter, see the Lenovo Press Product Guide found at the following address:
http://lenovopress.com/tips1027
The Intel I350-T4 ML2 Quad Port GbE Adapter has the following specifications:
- Quad-port 1 Gb Ethernet connectivity
- Intel I350-AM4 ASIC
- RJ45 ports for copper cables
For more information about this adapter, see the Lenovo Press Product Guide:
http://lenovopress.com/tips1155
The following table lists the supported ML2 adapters.
Table 18. ML2 adapters
Part number | Feature code |
Description | Maximum supported x3850 X6 |
00D2026 | A40S | Broadcom NetXtreme II ML2 Dual Port 10GbaseT for System x | 1 |
00D2028 | A40T | Broadcom NetXtreme II ML2 Dual Port 10GbE SFP+ for System x | 1 |
00D1996 | A40Q | Emulex VFA5 ML2 Dual Port 10GbE SFP+ Adapter for System x | 1 |
00D8544 | A4NZ | Emulex VFA5 ML2 FCoE/iSCSI License for System x (FoD) (Features on Demand upgrade for 00D1996 - one for each adapter) |
1 |
00D1998 | A40R | Intel I350-T4 ML2 Quad Port GbE Adapter for System x | 1 |
00D1994 | A40P | Intel X540 ML2 Dual Port 10GbaseT Adapter for System x | 1 |
94Y5200 | AS74 | Intel X710 ML2 4x10GbE SFP+ Adapter for System x | 1 |
00FP650 | A5RK | Mellanox ConnectX-3 Pro ML2 2x40GbE/FDR VPI Adapter for System x | 1 |
The server also supports various other Ethernet and InfiniBand network adapters, as listed in the following table. The maximum quantity listed is for configurations with all processors and I/O books installed.
Part number | Feature code |
Description | Maximum supported x3850 X6 |
40 Gb Ethernet | |||
00D9550 | A3PN | Mellanox ConnectX-3 40GbE / FDR IB VPI Adapter for System x | 9 |
10 Gb Ethernet | |||
44T1370 | A5GZ | Broadcom NetXtreme 2x10GbE BaseT Adapter for System x | 9 |
49Y7910 | A18Y | Broadcom NetXtreme II Dual Port 10GBaseT Adapter for System x | 9 |
00JY820 | A5UT | Emulex VFA5 2x10 GbE SFP+ PCIe Adapter for System x | 9 |
00JY830 | A5UU | Emulex VFA5 2x10 GbE SFP+ Adapter and FCoE/iSCSI SW for System x | 9 |
00JY824 | A5UV | Emulex VFA5 FCoE/iSCSI SW for PCIe Adapter for System x (FoD) | 9 |
00D8540 | A4M9 | Emulex Dual Port 10GbE SFP+ VFA III-R for System x | 9 |
49Y7960 | A2EC | Intel X520 Dual Port 10GbE SFP+ Adapter for System x | 9 |
49Y7970 | A2ED | Intel X540-T2 Dual Port 10GBaseT Adapter for System x | 9 |
81Y3520 | AS73 | Intel X710 2x10GbE SFP+ Adapter for System x | 9 |
00D9690 | A3PM | Mellanox ConnectX-3 10 GbE Adapter for System x | 9 |
90Y4600 | A3MR | QLogic 8200 Dual Port 10GbE SFP+ VFA for System x | 9 |
00Y5624 | A3MT | QLogic 8200 VFA FCoE/iSCSI License for System x (FoD) | 9 |
47C9960 | A47J | Solarflare SFN6122F 2x10GbE SFP+ Onload Adapter | 9 |
Gigabit Ethernet | |||
00AG500 | A56K | Intel I350-F1 1xGbE Fiber Adapter for System x | 9 |
00AG510 | A56L | Intel I350-T2 2xGbE BaseT Adapter for System x | 9 |
00AG520 | A56M | Intel I350-T4 4xGbE BaseT Adapter for System x | 9 |
90Y9370 | A2V4 | Broadcom NetXtreme I Dual Port GbE Adapter for System x | 9 |
90Y9352 | A2V3 | Broadcom NetXtreme I Quad Port GbE Adapter for System x | 9 |
49Y4230 | 5767 | Intel Ethernet Dual Port Server Adapter I340-T2 for System x | 9 |
49Y4240 | 5768 | Intel Ethernet Quad Port Server Adapter I340-T4 for System x | 9 |
InfiniBand | |||
00D9550 | A3PN | Mellanox ConnectX-3 40GbE / FDR IB VPI Adapter for System x | 9 |
For more information, see the list of Lenovo Press Product Guides in the Networking adapters category found at the following address:
http://lenovopress.com/systemx/networkadapters
Fibre Channel host bus adapters
The following table lists the supported Fibre Channel HBAs
Part number | Feature code |
Description | Maximum supported |
Fibre Channel - 16 Gb | |||
81Y1655 | A2W5 | Emulex 16Gb FC Single-port HBA for System x | 9 |
81Y1662 | A2W6 | Emulex 16Gb FC Dual-port HBA for System x | 9 |
81Y1668 | A2XU | Brocade 16Gb FC Single-port HBA for System x | 9 |
81Y1675 | A2XV | Brocade 16Gb FC Dual-port HBA for System x | 9 |
00Y3337 | A3KW | QLogic 16Gb FC Single-port HBA for System x | 9 |
00Y3341 | A3KX | QLogic 16Gb FC Dual-port HBA for System x | 9 |
Fibre Channel - 8 Gb | |||
42D0485 | 3580 | Emulex 8 Gb FC Single-port HBA for System x | 9 |
42D0494 | 3581 | Emulex 8 Gb FC Dual-port HBA for System x | 9 |
42D0501 | 3578 | QLogic 8 Gb FC Single-port HBA for System x | 9 |
42D0510 | 3579 | QLogic 8 Gb FC Dual-port HBA for System x | 9 |
46M6049 | 3589 | Brocade 8 Gb FC Single-port HBA for System x | 9 |
46M6050 | 3591 | Brocade 8 Gb FC Dual-port HBA for System x | 9 |
For more information, see the list of Lenovo Press Product Guides in the Host bus adapters category found at the following address:
http://lenovopress.com/systemx/hba
SAS adapters for external storage
The following table lists the supported SAS HBAs and RAID adapters.
Part number | Feature code |
Description | Maximum supported |
SAS HBAs | |||
46C9010 | A3MV | N2125 SAS/SATA HBA | 9 |
00AE912 | A5M0 | N2225 SAS/SATA HBA | 9 |
RAID controllers | |||
00AE938 | A5ND | ServeRAID M5225-2GB SAS/SATA Controller | 3 |
81Y4478 | A1WX | ServeRAID M5120 SAS/SATA Controller | 2 |
Features on Demand upgrades for the M5225 | |||
47C8706 | A3Z5 | ServeRAID M5200 Series RAID 6 Upgrade for Systems-FoD | 1 |
47C8710 | A3Z7 | ServeRAID M5200 Series Performance Accelerator for Systems-FoD | 1 |
47C8712 | A3Z8 | ServeRAID M5200 Series SSD Caching Enabler for Systems-FoD | 1 |
Hardware upgrades for the M5120 | |||
81Y4487 | A1J4 | ServeRAID M5100 Series 512MB Flash/RAID 5 Upgrade | 1 |
81Y4559 | A1WY | ServeRAID M5100 Series 1GB Flash/RAID 5 Upgrade | 1 |
47C8670 | A4G6 | ServeRAID M5100 Series 2GB Flash/RAID 5 Upgrade | 1 |
Feature on Demand upgrades for the M5120 | |||
90Y4318 | A2MD | ServeRAID M5100 Series SSD Caching Enabler | 1* |
90Y4273 | A2MC | ServeRAID M5100 Series SSD Performance Key | 1* |
81Y4546 | A1X3 | ServeRAID M5100 Series RAID 6 Upgrade | 1* |
* These M5120 features upgrades require a cache memory upgrade (81Y4487, 81Y4559, or 47C8670).
The ServeRAID M5225 SAS/SATA Controller has the following specifications:
- Eight external 12 Gbps SAS/SATA ports
- Supports 12, 6, and 3 Gbps SAS and 6 and 3 Gbps SATA data transfer rates
- Two external x4 mini-SAS HD connectors (SFF-8644)
- Supports 2 GB flash-backed cache (standard)
- Supports RAID levels 0, 1, 5, 10, and 50 (standard)
- Supports RAID 6 and 60 with the optional M5200 Series RAID 6 Upgrade
- Supports optional M5200 Series Performance Accelerator and SSD Caching upgrades
- PCIe x8 Gen 3 host interface
- Based on the LSI SAS3108 12 Gbps ROC controller
- Supports connectivity to the EXP2512 and EXP2524 storage expansion enclosures
For more information about the ServeRAID M5225, see the Lenovo Press Product Guide at http://lenovopress.com/tips1258
The ServeRAID M5120 SAS/SATA Controller has the following specifications:
- Eight external 6 Gbps SAS/SATA ports
- Up to 6 Gbps throughput per port
- Two external x4 mini-SAS connectors (SFF-8088)
- Supports RAID 0, 1, and 10
- Supports RAID 5 and 50 with optional M5100 Series RAID 5 upgrades
- Supports RAID 6 and 60 with the optional M5100 Series RAID 6 upgrade
- Supports 512 MB or 1 GB flash-backed cache
- PCIe 3.0 x8 host interface
- Based on the LSI SAS2208 6 Gbps ROC controller
- Supports connectivity to the EXP2512 and EXP2524 storage expansion enclosures
Cache upgrade required: The ServeRAID M5120 SAS/SATA Controller ships standard without a cache. One of the available cache upgrades (81Y4487, 81Y4559, or 47C8670) is required for the M5120 adapter operations, and it must be purchased together with the controller.
For more information about the ServeRAID M5120, see the Lenovo Press Product Guide at http://lenovopress.com/tips0858
PCIe SSD adapters
The server supports the High IOPS SSD adapters that are listed in the following table. The maximum quantity listed is for configurations with all processors and I/O books installed.
Table 22. SSD adapters
Part number | Feature code |
Description | Maximum supported x3850 X6 |
46C9078 | A3J3 | 365GB High IOPS MLC Mono Adapter | 9 |
46C9081 | A3J4 | 785GB High IOPS MLC Mono Adapter | 9 |
90Y4377 | A3DY | 1.2TB High IOPS MLC Mono Adapter | 9 |
90Y4397 | A3DZ | 2.4TB High IOPS MLC Duo Adapter | 9 |
00AE995 | ARYP | 1000GB Enterprise io3 Flash Adapter | 6 |
00AE998 | ARYQ | 1300GB Enterprise io3 Flash Adapter | 6 |
00JY004 | ARYS | 5200GB Enterprise io3 Flash Adapter | 6 |
00JY001 | ARYR* | 2600GB Enterprise io3 Flash Adapter | 6 |
00AE983 | ARYK | 1250GB Enterprise Value io3 Flash Adapter | 6 |
00AE986 | ARYL | 1600GB Enterprise Value io3 Flash Adapter | 6 |
00AE989 | ARYM | 3200GB Enterprise Value io3 Flash Adapter | 6 |
00AE992 | ARYN* | 6400GB Enterprise Value io3 Flash Adapter | 6 |
* These adapters cannot be ordered via CTO. It can only be ordered as an option. The server cannot be shipped with this adapter installed. See http://ibm.com/support/entry/portal/docdisplay?lndocid=SERV-IO3
For more information about these adapters, see the Lenovo Press Product Guides in the Internal Storage category: http://lenovopress.com/systemx/internalstorage
GPU adapters and co-processors
The server supports the co-processors and graphics processing units (GPUs) that are listed in the following table. Each is installed in a Full-length I/O Book. No other adapter can be installed in the Full-length I/O Book. The Full-length I/O Book includes the necessary auxiliary power cables.
Notes:
- These adapters are not available through CTO and cannot be shipped installed in the server because they are installed in the Full-length I/O Book, which extends beyond the rear of the chassis (see Figure 12). These adapters must be shipped separately from the server. Order the adapter and Full-length I/O Book as separate options.
- If a NVIDIA Grid K1, Grid K2, Tesla K20, Tesla K40c, Quadro K4000 or Quadro K6000 is installed, the maximum system memory that can be installed is 1 TB.
Table 23. GPU adapters
Part number | Feature code | Description | Minimum system RAM |
Maximum supported x3850 X6 |
00J6160 | A3GM* | NVIDIA GRID K1 | 32 GB | 2 |
00FP674 | A470* | NVIDIA Grid K2 (Actively Cooled) | 16 GB | 2 |
00FP675 | A3YU* | NVIDIA Quadro K4000 | 6 GB | 2 |
00FP672 | A3YV* | NVIDIA Quadro K6000 | 24 GB | 2 |
00FP673 | A471* | NVIDIA Tesla K20 (Actively Cooled) | 10 GB | 2 |
00FP676 | A5FG* | NVIDIA Tesla K40c | 24 GB | 2 |
* Not available through CTO.
Power supplies
The x3850 X6 server supports up to four redundant power supplies. Standard models come with one, two, or four power supplies (model dependent). The following table lists the power supplies.
Table 24. Power supplies
Part number | Feature code | Description | Maximum supported x3850 X6 |
Models where used |
44X4150 | A54D | 1400W HE Redundant Power Supply for altitudes >5000 meters |
4 | All HANA models |
44X4152 | A54E | 1400W HE Redundant Power Supply | 4 | - |
44X4132 | A4R0 | 900W Power Supply | 4 | A4x, B1x, B3x, C1x, C4x |
88Y7433 | A2EA | 750W High Efficiency -48 V DC Power Supply | 4 | - |
An AC power supply ships standard with one 2.8 m C13 - C14 power cord.
Configuration rules are as follows:
- Power supplies must be in pairs (x3850 X6) or quads (x3950 X6), with the exception of model 3837-A4x, where one power supply is supported.
- The AC power supplies can be mixed. Valid combinations for the x3850 X6 for example, are:
- Two 44X4132 and two 44X4152
- Two 44X4132 and two 44X4150
- It is not recommended you mix the two 1400 W options (44X4152 for low altitude and 44X4150 for high altitude) as you will nullify the high-altitude capabilities of 44X4150.
- You cannot mix the AC power supplies with the DC power supply
- Use the Power Configurator to determine exactly what power your server needs:
http://ibm.com/systems/bladecenter/resources/powerconfig.html
Integrated virtualization
The server supports VMware ESXi that is installed on a USB memory key. The key is installed in a USB socket that is on the primary I/O book inside the server. The following table lists the virtualization options.
Table 25. Virtualization options
Part number | Feature code |
Description | Maximum supported |
41Y8298 | A2G0 | Blank USB Memory Key for VMware ESXi Downloads | 1 |
41Y8382 | A4WZ | USB Memory Key for VMware ESXi 5.1 U1 | 1 |
Systems management
The server contains Integrated Management Module II (IMM2), which provides advanced service-processor control, monitoring, and an alerting function. If an environmental condition exceeds a threshold or if a system component fails, the IMM2 lights LEDs to help you diagnose the problem, records the error in the event log, and alerts you to the problem. The IMM2 also provides a virtual presence capability for remote server management capabilities.
The IMM2 provides remote server management through industry-standard interfaces:
- Intelligent Platform Management Interface (IPMI) Version 2.0
- Simple Network Management Protocol (SNMP) Version 3
- Common Information Model (CIM)
- Web browser
The remote presence provides the following functions:
- Remotely viewing video with graphics resolutions up to 1600 x 1200 at 75 Hz with up to 23 bits per pixel colors, regardless of the system state
- Remotely accessing the server by using the keyboard and mouse from a remote client
- Mapping the CD or DVD drive, diskette drive, and USB flash drive on a remote client, and mapping ISO and diskette image files as virtual drives that are available for use by the server
- Uploading a diskette image to the IMM memory and mapping it to the server as a virtual drive
The blue-screen capture feature captures the video display contents before the IMM restarts the server when the IMM detects an operating-system hang condition. A system administrator can use the blue-screen capture feature to assist in determining the cause of the hang condition.
Supported operating systems
The server supports the following operating systems:
- Microsoft Windows Server 2008 R2
- Microsoft Windows Server 2012
- Microsoft Windows Server 2012 R2
- Red Hat Enterprise Linux 6 Server x64 Edition
- Red Hat Enterprise Linux 7
- SUSE Enterprise Linux Server (SLES) 12
- SUSE LINUX Enterprise Server 11 for AMD64/EM64T
- SUSE LINUX Enterprise Server 11 with Xen for AMD64/EM64T
- SUSE Linux Enterprise Server 12 with XEN
- VMware vSphere 5.1 (ESXi)
- VMware vSphere 5.5 (ESXi)
For the latest information about the specific versions and service levels that are supported and any other prerequisites, see the Lenovo Operating System Interoperability Guide:
http://lenovopress.com/osig
Physical and electrical specifications
Dimensions and weight:
- Height: 173 mm (6.8 in.)
- Width: 482 mm (19.0 in.)
- Depth: 804 mm (31.6 in)
- Depth with cable management brackets installed: 836 mm (32.9”)
- Depth with Full-length I/O Book installed: 921 mm (36.2 in)
- Weight:
- Minimum configuration: 35.9 kg (79.2 lb)
- Typical configuration: 46.4 kg (102.3 lb)
- Maximum configuration: 54.7 kg (120 lb)
Supported environment:
- Air temperature:
- Server on: 5 °C to 40 °C (41 °F to 104 °F); altitude: 0 - 3,050 m (10,000 ft).
- Server off: 5 °C to 45 °C (41 °F to 113 °F); altitude: 0 - 3,050 m (10,000 ft).
- Shipment: -40 °C to 60 °C (-40 °F to 140 °F)
- Humidity:
- Server on: 8% - 85%, maximum dew point 24 °C
- Server off: 8% - 85%, maximum dew point 27 °C
- Electrical:
- Models with 1400 W AC power supplies:
- 100 -127 (nominal) V AC; 50 Hz or 60 Hz; 10 A (900 W DC output)
- 200 - 240 (nominal) V AC; 50 Hz or 60 Hz; 8 A (1400 W DC output)
- Input kilovolt-amperes (kVA) (approximately):
- Minimum configuration: 0.16 kVA
- Maximum configuration: 3.2 kVA
- Models with 900 W AC power supplies:
- 100 - 127 (nominal) V AC; 50 Hz or 60 Hz; 10.7 A
- 200 - 240 (nominal) V AC; 50 Hz or 60 Hz; 5.3 A
- Input kilovolt-amperes (kVA) (approximately):
- Minimum configuration: 0.16 kVA
- Maximum configuration: 2.0 kVA
- Models with 750 W DC power supplies:
- -40 to -75 (nominal) V DC
- Input kilovolt-amperes (kVA) (approximately):
- Minimum configuration: 0.16 kVA
- Maximum configuration: 1.7 kVA
- Models with 1400 W AC power supplies:
- BTU output:
- Minimum configuration: 546 Btu/hr (160 watts)
- Maximum configuration: 10,912 Btu/hr (3,200 watts)
- Noise level:
- 6.6 bels (operating)
- 6.4 bels (idle)
Warranty options
The system has a three-year warranty with 24x7 standard call center support and 9x5 Next Business Day onsite coverage. Also available are Lenovo Services warranty maintenance upgrades and post-warranty maintenance agreements, with a well-defined scope of services, including service hours, response time, term of service, and service agreement terms and conditions.
Lenovo warranty service upgrade offerings are region-specific. Not all warranty service upgrades are available in every region. For more information about Lenovo warranty service upgrade offerings that are available in your region, go to the Data Center Advisor and Configurator website http://dcsc.lenovo.com, then do the following:
- In the Customize a Model box in the middle of the page, select the Services option in the Customization Option dropdown menu
- Enter in the machine type & model of the system
- From the search results, you can click either Deployment Services or Support Services to view the offerings
The following table explains warranty service definitions in more detail.
Term | Description |
---|---|
On-site service | A service technician will arrive at the client’s location for equipment service. |
24x7x2 hour | A service technician is scheduled to arrive at the client’s location within two hours after remote problem determination is completed. Lenovo provides service around the clock, every day, including Lenovo holidays. |
24x7x4 hour | A service technician is scheduled to arrive at the client’s location within four hours after remote problem determination is completed. Lenovo provides service around the clock, every day, including Lenovo holidays. |
9x5x4 hour | A service technician is scheduled to arrive at the client’s location within four business hours after remote problem determination is completed. Lenovo provides service 8:00 am - 5:00 pm in the client's local time zone, Monday-Friday, excluding Lenovo holidays. For example, if a customer reports an incident at 3:00 pm on Friday, the technician will arrive by 10:00 am the following Monday. |
9x5 next business day | A service technician is scheduled to arrive at the client’s location on the business day after remote problem determination is completed. Lenovo provides service 8:00 am - 5:00 pm in the client's local time zone, Monday - Friday, excluding Lenovo holidays. Calls received after 4:00 pm local time require an extra business day for service dispatch. Next business day service is not guaranteed. |
Committed Repair | Problems receive priority handling so that repairs are completed within the committed time of 6, 8, or 24 hours. Lenovo provides service 24 hours/day, every day, including Lenovo holidays. |
The following Lenovo warranty service upgrades are available:
- Warranty and maintenance service upgrades:
- Three, four, or five years of 9x5 or 24x7 service coverage
- Onsite response from next business day to 2 or 4 hours
- Committed repair service
- Warranty extension of up to 5 years
- Post warranty extensions
- Committed Repair Service
Committed Repair Services enhances the level of Warranty Service Upgrade or Post Warranty/Maintenance Service offering associated with the selected systems. Offerings vary and are available in select countries.
- Priority handling to meet defined time frames to restore the failing machine to good working condition
- Committed repair service levels are measured within the following coverage hours:
- 24x7x6: Service performed 24 hours per day, 7 days per week, within 6 hours
- 24x7x8: Service performed 24 hours per day, 7 days per week, within 8 hours
- 24x7x24: Service performed 24 hours per day, 7 days per week, within 24 hours
- Hard Disk Drive Retention
Lenovo’s Hard Disk Drive Retention (HDDR) service is a multi-drive hard drive retention offering that ensures your data is always under your control, regardless of the number of hard drives that are installed in your Lenovo server. In the unlikely event of a hard drive failure, you retain possession of your hard drive while Lenovo replaces the failed drive part. Your data stays safely on your premises, in your hands. The Hard Drive Retention service can be purchased in convenient bundles with our warranty upgrades and extensions.
- Microcode Support
Keeping microcode current helps prevent hardware failures and security exposure. There are two levels of service: analysis of the installed base and analysis and update where required. Offerings vary by region and can be bundled with other warranty upgrades and extensions.
- Remote Technical Support Services (RTS)
RTS provides comprehensive technical call center support for covered servers, storage, operating systems, and applications. Providing a single source for support of hardware and software issues, RTS can reduce problem resolution time, decreasing the cost to address technical problems and increasing uptime. Offerings are available for Windows, Linux, IBM Systems Director, VMware, Microsoft business applications, and Lenovo System x storage devices, and IBM OEM storage devices.
Regulatory compliance
The server conforms to the following regulations:
- FCC - Verified to comply with Part 15 of the FCC Rules, Class A
- Canada ICES-003, issue 4, Class A
- UL/IEC 60950-1
- CSA C22.2 No. 60950-1
- NOM-019
- Argentina IEC60950-1
- Japan VCCI, Class A
- Australia/New Zealand AS/NZS CISPR 22, Class A
- IEC 60950-1(CB Certificate and CB Test Report)
- China CCC (GB4943), GB9254 Class A, GB17625.1
- Taiwan BSMI CNS13438, Class A; CNS14336-1
- Korea KN22, Class A; KN24
- Russia/GOST ME01, IEC-60950-1, GOST R 51318.22, GOST R 51318.24, GOST R 51317.3.2, and GOST R 51317.3.3
- IEC 60950-1 (CB Certificate and CB Test Report)
- CE Mark (EN55022 Class A, EN60950-1, EN55024, EN61000-3-2, and EN61000-3-3)
- CISPR 22, Class A
- TUV-GS (EN60950-1 /IEC60950-1, EK1-ITB2000)
External drive enclosures
The server supports attachment to external drive enclosures using a RAID controller with external ports or a SAS host bus adapter. Adapters supported by the server are listed in the SAS adapters for external storage section.
The following table lists the 6 Gbps SAS external drive enclosures that are offered by Lenovo that can be used with the server for storage expansion.
Part number | Description |
---|---|
64111B1 | Lenovo Storage E1012 LFF Disk Expansion Single SAS IO Module, Rail Kit, 9x5 NBD |
64111B2 | Lenovo Storage E1012 LFF Disk Expansion Dual SAS IO Module, Rail Kit, 9x5 NBD |
64111B3 | Lenovo Storage E1024 SFF Disk Expansion Single SAS IO Module, Rail Kit, 9x5 NBD |
64111B4 | Lenovo Storage E1024 SFF Disk Expansion Dual SAS IO Module, Rail Kit, 9x5 NBD |
For details about supported drives and cables for the Lenovo Storage E1012 and E1024, see the Lenovo Press Product Guide:
http://lenovopress.com/lp0043
The following table lists the 12 Gbps SAS external drive enclosures offered by Lenovo that can be used with the server for storage expansion.
Note: Information provided in this section is for ordering reference purposes only. For the operating system and adapter support details, refer to the interoperability matrix for a particular storage enclosure that can be found on the Lenovo Data Center Support web site:
http://datacentersupport.lenovo.com
Description | Part number | ||
---|---|---|---|
Worldwide | Japan | PRC | |
Lenovo Storage D1212 LFF Disk Expansion with Dual SAS IO Modules | 4587A11 | 4587A1J | 4587A1C |
Lenovo Storage D1224 SFF Disk Expansion with Dual SAS IO Modules | 4587A31 | 4587A3J | 4587A3C |
Lenovo Storage D3284 4TB x 84 HD Expansion Enclosure | 641311F | ||
Lenovo Storage D3284 6TB x 84 HD Expansion Enclosure | 641312F | ||
Lenovo Storage D3284 8TB x 84 HD Expansion Enclosure | 641313F | ||
Lenovo Storage D3284 10TB x 84 HD Expansion Enclosure | 641314F |
For details about supported drives, adapters, and cables, see the following Lenovo Press Product Guides:
- Lenovo Storage D1212 and D1224
http://lenovopress.com/lp0512 - Lenovo Storage D3284
http://lenovopress.com/lp0513
External storage systems
Lenovo offers the ThinkSystem DE Series and ThinkSystem DM Series external storage systems for high-performance storage. See the DE Series and DM Series product guides for specific controller models, expansion enclosures and configuration options:
- ThinkSystem DE Series Storage
https://lenovopress.com/storage/thinksystem/de-series#rt=product-guide - ThinkSystem DM Series Storage
https://lenovopress.com/storage/thinksystem/dm-series#rt=product-guide - ThinkSystem DG Series Storage
https://lenovopress.com/storage/thinksystem/dg-series#rt=product-guide
External backup units
The following table lists the external backup options that are offered by Lenovo.
Part number | Description |
---|---|
External RDX USB drives | |
4T27A10725 | ThinkSystem RDX External USB 3.0 Dock |
External SAS tape backup drives | |
6160S7E | IBM TS2270 Tape Drive Model H7S |
6160S8E | IBM TS2280 Tape Drive Model H8S |
6160S9E | IBM TS2290 Tape Drive Model H9S |
External SAS tape backup autoloaders | |
6171S7R | IBM TS2900 Tape Autoloader w/LTO7 HH SAS |
6171S8R | IBM TS2900 Tape Autoloader w/LTO8 HH SAS |
6171S9R | IBM TS2900 Tape Autoloader w/LTO9 HH SAS |
External tape backup libraries | |
6741A1F | IBM TS4300 3U Tape Library-Base Unit |
6741A3F | IBM TS4300 3U Tape Library-Expansion Unit |
Full High 8 Gb Fibre Channel for TS4300 | |
01KP938 | LTO 7 FH Fibre Channel Drive |
01KP954 | LTO 8 FH Fibre Channel Drive |
02JH837 | LTO 9 FH Fibre Channel Drive |
Half High 8 Gb Fibre Channel for TS4300 | |
01KP936 | LTO 7 HH Fibre Channel Drive |
01KP952 | LTO 8 HH Fibre Channel Drive |
02JH835 | LTO 9 HH Fibre Channel Drive |
Half High 6 Gb SAS for TS4300 | |
01KP937 | LTO 7 HH SAS Drive |
01KP953 | LTO 8 HH SAS Drive |
02JH836 | LTO 9 HH SAS Drive |
For more information, see the list of Product Guides in the Backup units category:
https://lenovopress.com/servers/options/backup
Top-of-rack Ethernet switches
The following table lists the Ethernet LAN switches that are offered by Lenovo.
Part number | Description |
---|---|
1 Gb Ethernet Rack switches | |
7Y810011WW | Lenovo ThinkSystem NE0152T RackSwitch (Rear to Front) |
7Z320O11WW | Lenovo ThinkSystem NE0152TO RackSwitch (Rear to Front, ONIE) |
7159BAX | Lenovo RackSwitch G7028 (Rear to Front) |
7159CAX | Lenovo RackSwitch G7052 (Rear to Front) |
7159G52 | Lenovo RackSwitch G8052 (Rear to Front) |
7165H1X | Juniper EX2300-C PoE Switch |
7165H2X | Juniper EX2300-24p PoE Switch |
1 Gb Ethernet Campus switches | |
7Z340011WW | Lenovo CE0128TB Switch (3-Year Warranty) |
7Z360011WW | Lenovo CE0128TB Switch (Limited Lifetime Warranty) |
7Z340012WW | Lenovo CE0128PB Switch (3-Year Warranty) |
7Z360012WW | Lenovo CE0128PB Switch (Limited Lifetime Warranty) |
7Z350021WW | Lenovo CE0152TB Switch (3-Year Warranty) |
7Z370021WW | Lenovo CE0152TB Switch (Limited Lifetime Warranty) |
7Z350022WW | Lenovo CE0152PB Switch (3-Year Warranty) |
7Z370022WW | Lenovo CE0152PB Switch (Limited Lifetime Warranty) |
10 Gb Ethernet switches | |
7159A1X | Lenovo ThinkSystem NE1032 RackSwitch (Rear to Front) |
7159B1X | Lenovo ThinkSystem NE1032T RackSwitch (Rear to Front) |
7Z330O11WW | Lenovo ThinkSystem NE1064TO RackSwitch (Rear to Front, ONIE) |
7159C1X | Lenovo ThinkSystem NE1072T RackSwitch (Rear to Front) |
7159CRW | Lenovo RackSwitch G8272 (Rear to Front) |
7159GR6 | Lenovo RackSwitch G8296 (Rear to Front) |
7159BR6 | Lenovo RackSwitch G8124E (Rear to Front) |
25 Gb Ethernet switches | |
7159E1X | Lenovo ThinkSystem NE2572 RackSwitch (Rear to Front) |
7Z210O21WW | Lenovo ThinkSystem NE2572O RackSwitch (Rear to Front, ONIE) |
7Z330O21WW | Lenovo ThinkSystem NE2580O RackSwitch (Rear to Front, ONIE) |
100 Gb Ethernet switches | |
7159D1X | Lenovo ThinkSystem NE10032 RackSwitch (Rear to Front) |
7Z210O11WW | Lenovo ThinkSystem NE10032O RackSwitch (Rear to Front, ONIE) |
For more information, see the list of Product Guides in the following switch categories:
- 1 Gb Ethernet switches: http://lenovopress.com/networking/tor/1gb?rt=product-guide
- 10 Gb Ethernet switches: http://lenovopress.com/networking/tor/10gb?rt=product-guide
- 25 Gb Ethernet switches: http://lenovopress.com/networking/tor/25gb?rt=product-guide
- 40 Gb Ethernet switches: http://lenovopress.com/networking/tor/40gb?rt=product-guide
- 100 Gb Ethernet switches: https://lenovopress.com/networking/tor/100Gb?rt=product-guide
Fibre Channel SAN switches
Lenovo offers the ThinkSystem DB Series of Fibre Channel SAN switches for high-performance storage expansion. See the DB Series product guides for models and configuration options:
- ThinkSystem DB Series SAN Switches:
https://lenovopress.com/storage/switches/rack#rt=product-guide
Uninterruptible power supply units
The following table lists the uninterruptible power supply (UPS) units that are offered by Lenovo.
Part number | Description |
---|---|
Rack-mounted or tower UPS units - 100-125VAC | |
7DD5A001WW | RT1.5kVA 2U Rack or Tower UPS-G2 (100-125VAC) |
55941AX | RT1.5kVA 2U Rack or Tower UPS (100-125VAC) |
55942AX | RT2.2kVA 2U Rack or Tower UPS (100-125VAC) |
7DD5A003WW | RT3kVA 2U Rack or Tower UPS-G2 (100-125VAC) |
55943AX | RT3kVA 2U Rack or Tower UPS (100-125VAC) |
Rack-mounted or tower UPS units - 200-240VAC | |
7DD5A002WW | RT1.5kVA 2U Rack or Tower UPS-G2 (200-240VAC) |
55941KX | RT1.5kVA 2U Rack or Tower UPS (200-240VAC) |
55942KX | RT2.2kVA 2U Rack or Tower UPS (200-240VAC) |
7DD5A005WW | RT3kVA 2U Rack or Tower UPS-G2 (200-240VAC) |
55943KX | RT3kVA 2U Rack or Tower UPS (200-240VAC) |
7DD5A007WW | RT5kVA 3U Rack or Tower UPS-G2 (200-240VAC) |
55945KX | RT5kVA 3U Rack or Tower UPS (200-240VAC) |
7DD5A008WW | RT6kVA 3U Rack or Tower UPS-G2 (200-240VAC) |
55946KX | RT6kVA 3U Rack or Tower UPS (200-240VAC) |
55948KX | RT8kVA 6U Rack or Tower UPS (200-240VAC) |
7DD5A00AWW | RT11kVA 6U Rack or Tower UPS-G2 (200-240VAC) |
55949KX | RT11kVA 6U Rack or Tower UPS (200-240VAC) |
55943KT† | ThinkSystem RT3kVA 2U Standard UPS (200-230VAC) (2x C13 10A, 2x GB 10A, 1x C19 16A outlets) |
55943LT† | ThinkSystem RT3kVA 2U Long Backup UPS (200-230VAC) (2x C13 10A, 2x GB 10A, 1x C19 16A outlets) |
55946KT† | ThinkSystem RT6kVA 5U UPS (200-230VAC) (2x C13 10A outlets, 1x Terminal Block output) |
5594XKT† | ThinkSystem RT10kVA 5U UPS (200-230VAC) (2x C13 10A outlets, 1x Terminal Block output) |
Rack-mounted or tower UPS units - 380-415VAC | |
55948PX | RT8kVA 6U 3:1 Phase Rack or Tower UPS (380-415VAC) |
55949PX | RT11kVA 6U 3:1 Phase Rack or Tower UPS (380-415VAC) |
† Only available in China and the Asia Pacific market.
For more information, see the list of Product Guides in the UPS category:
https://lenovopress.com/servers/options/ups
Power distribution units
The following table lists the power distribution units (PDUs) that are offered by Lenovo.
Part number |
Feature code |
Description |
ANZ
|
ASEAN
|
Brazil
|
EET
|
MEA
|
RUCIS
|
WE
|
HTK
|
INDIA
|
JAPAN
|
LA
|
NA
|
PRC
|
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
0U Basic PDUs | |||||||||||||||
4PU7A93176 | C0QH | 0U 36 C13 and 6 C19 Basic 32A 1 Phase PDU v2 | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
4PU7A93169 | C0DA | 0U 36 C13 and 6 C19 Basic 32A 1 Phase PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
4PU7A93177 | C0QJ | 0U 24 C13/C15 and 24 C13/C15/C19 Basic 32A 3 Phase WYE PDU v2 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
4PU7A93170 | C0D9 | 0U 24 C13/C15 and 24 C13/C15/C19 Basic 32A 3 Phase WYE PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
00YJ776 | ATZY | 0U 36 C13/6 C19 24A 1 Phase PDU | N | Y | Y | N | N | N | N | N | N | Y | Y | Y | N |
00YJ779 | ATZX | 0U 21 C13/12 C19 48A 3 Phase PDU | N | N | Y | N | N | N | Y | N | N | Y | Y | Y | N |
00YJ777 | ATZZ | 0U 36 C13/6 C19 32A 1 Phase PDU | Y | Y | N | Y | Y | Y | Y | Y | Y | N | N | Y | Y |
00YJ778 | AU00 | 0U 21 C13/12 C19 32A 3 Phase PDU | Y | Y | N | Y | Y | Y | Y | Y | Y | N | N | Y | Y |
0U Switched and Monitored PDUs | |||||||||||||||
4PU7A93181 | C0QN | 0U 21 C13/C15 and 21 C13/C15/C19 Switched and Monitored 48A 3 Phase Delta PDU V2 (60A derated) | N | Y | N | N | N | N | N | Y | N | Y | N | Y | N |
4PU7A93174 | C0D5 | 0U 21 C13/C15 and 21 C13/C15/C19 Switched and Monitored 48A 3 Phase Delta PDU (60A derated) | N | Y | N | Y | N | N | Y | Y | N | N | N | Y | N |
4PU7A93178 | C0QK | 0U 20 C13 and 4 C19 Switched and Monitored 32A 1 Phase PDU v2 | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
4PU7A93171 | C0D8 | 0U 20 C13 and 4 C19 Switched and Monitored 32A 1 Phase PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
4PU7A93182 | C0QP | 0U 18 C13/C15 and 18 C13/C15/C19 Switched and Monitored 63A 3 Phase WYE PDU v2 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
4PU7A93175 | C0CS | 0U 18 C13/C15 and 18 C13/C15/C19 Switched and Monitored 63A 3 Phase WYE PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
4PU7A93180 | C0QM | 0U 18 C13/C15 and 18 C13/C15/C19 Switched and Monitored 32A 3 Phase WYE PDU v2 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
4PU7A93173 | C0D6 | 0U 18 C13/C15 and 18 C13/C15/C19 Switched and Monitored 32A 3 Phase WYE PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y |
4PU7A93179 | C0QL | 0U 16 C13/C15 and 16 C13/C15/C19 Switched and Monitored 24A 1 Phase PDU v2 (30A derated) | N | Y | N | N | N | N | N | Y | N | Y | N | Y | N |
4PU7A93172 | C0D7 | 0U 16 C13/C15 and 16 C13/C15/C19 Switched and Monitored 24A 1 Phase PDU(30A derated) | N | Y | N | Y | N | N | Y | Y | N | N | N | Y | N |
00YJ783 | AU04 | 0U 12 C13/12 C19 Switched and Monitored 48A 3 Phase PDU | N | N | Y | N | N | N | Y | N | N | Y | Y | Y | N |
00YJ781 | AU03 | 0U 20 C13/4 C19 Switched and Monitored 24A 1 Phase PDU | N | N | Y | N | Y | N | Y | N | N | Y | Y | Y | N |
00YJ782 | AU02 | 0U 18 C13/6 C19 Switched and Monitored 32A 3 Phase PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | N | Y |
00YJ780 | AU01 | 0U 20 C13/4 C19 Switched and Monitored 32A 1 Phase PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | N | Y |
1U Switched and Monitored PDUs | |||||||||||||||
4PU7A90808 | C0D4 | 1U 18 C19/C13 Switched and monitored 48A 3P WYE PDU V2 ETL | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
4PU7A81117 | BNDV | 1U 18 C19/C13 switched and monitored 48A 3P WYE PDU - ETL | N | N | N | N | N | N | N | N | N | N | N | Y | N |
4PU7A90809 | C0DE | 1U 18 C19/C13 Switched and monitored 48A 3P WYE PDU V2 CE | N | N | N | N | N | Y | Y | N | N | N | N | N | N |
4PU7A81118 | BNDW | 1U 18 C19/C13 switched and monitored 48A 3P WYE PDU - CE | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | N | Y |
4PU7A90810 | C0DD | 1U 18 C19/C13 Switched and monitored 80A 3P Delta PDU V2 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
4PU7A77467 | BLC4 | 1U 18 C19/C13 Switched and Monitored 80A 3P Delta PDU | N | N | N | N | N | N | N | N | N | Y | N | Y | N |
4PU7A90811 | C0DC | 1U 12 C19/C13 Switched and monitored 32A 3P WYE PDU V2 | N | N | N | N | N | Y | Y | N | N | N | N | N | N |
4PU7A77468 | BLC5 | 1U 12 C19/C13 switched and monitored 32A 3P WYE PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
4PU7A90812 | C0DB | 1U 12 C19/C13 Switched and monitored 60A 3P Delta PDU V2 | N | N | N | N | N | N | N | N | N | Y | N | N | N |
4PU7A77469 | BLC6 | 1U 12 C19/C13 switched and monitored 60A 3P Delta PDU | N | N | N | N | N | N | N | N | N | N | N | Y | N |
46M4002 | 5896 | 1U 9 C19/3 C13 Switched and Monitored DPI PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
46M4004 | 5894 | 1U 12 C13 Switched and Monitored DPI PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
46M4003 | 5897 | 1U 9 C19/3 C13 Switched and Monitored 60A 3 Phase PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
46M4005 | 5895 | 1U 12 C13 Switched and Monitored 60A 3 Phase PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
1U Ultra Density Enterprise PDUs (9x IEC 320 C13 + 3x IEC 320 C19 outlets) | |||||||||||||||
71763NU | 6051 | Ultra Density Enterprise C19/C13 PDU 60A/208V/3PH | N | N | Y | N | N | N | N | N | N | Y | Y | Y | N |
71762NX | 6091 | Ultra Density Enterprise C19/C13 PDU Module | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
1U C13 Enterprise PDUs (12x IEC 320 C13 outlets) | |||||||||||||||
39M2816 | 6030 | DPI C13 Enterprise PDU Plus Module (WW) | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
39Y8941 | 6010 | DPI C13 Enterprise PDU Module (WW) | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
1U C19 Enterprise PDUs (6x IEC 320 C19 outlets) | |||||||||||||||
39Y8948 | 6060 | DPI C19 Enterprise PDU Module (WW) | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
39Y8923 | 6061 | DPI Three-phase 60A/208V C19 Enterprise PDU (US) | N | N | Y | N | N | N | Y | N | N | N | Y | Y | N |
1U Front-end PDUs (3x IEC 320 C19 outlets) | |||||||||||||||
39Y8938 | 6002 | DPI Single-phase 30A/120V Front-end PDU (US) | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
39Y8939 | 6003 | DPI Single-phase 30A/208V Front-end PDU (US) | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
39Y8934 | 6005 | DPI Single-phase 32A/230V Front-end PDU (International) | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
39Y8940 | 6004 | DPI Single-phase 60A/208V Front-end PDU (US) | Y | N | Y | Y | Y | Y | Y | N | N | Y | Y | Y | N |
39Y8935 | 6006 | DPI Single-phase 63A/230V Front-end PDU (International) | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
1U NEMA PDUs (6x NEMA 5-15R outlets) | |||||||||||||||
39Y8905 | 5900 | DPI 100-127V NEMA PDU | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Line cords for 1U PDUs that ship without a line cord | |||||||||||||||
40K9611 | 6504 | 4.3m, 32A/380-415V, EPDU/IEC 309 3P+N+G 3ph wye (non-US) Line Cord | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
40K9612 | 6502 | 4.3m, 32A/230V, EPDU to IEC 309 P+N+G (non-US) Line Cord | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
40K9613 | 6503 | 4.3m, 63A/230V, EPDU to IEC 309 P+N+G (non-US) Line Cord | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
40K9614 | 6500 | 4.3m, 30A/208V, EPDU to NEMA L6-30P (US) Line Cord | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
40K9615 | 6501 | 4.3m, 60A/208V, EPDU to IEC 309 2P+G (US) Line Cord | N | N | Y | N | N | N | Y | N | N | Y | Y | Y | N |
40K9617 | 6505 | 4.3m, 32A/230V, Souriau UTG Female to AS/NZ 3112 (Aus/NZ) Line Cord | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
40K9618 | 6506 | 4.3m, 32A/250V, Souriau UTG Female to KSC 8305 (S. Korea) Line Cord | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
For more information, see the Lenovo Press documents in the PDU category:
https://lenovopress.com/servers/options/pdu
Rack cabinets
The Lenovo racks supported by the server are listed in the following table.
Table 33. Rack cabinets
Part number | Description | Supported by x3850 X6 |
Maximum supported x3850 X6 |
2018-86X | 11U Office Enablement Kit | No | Not applicable |
9307-2PX | 25U Static S2 Standard Rack | No | Not applicable |
9307-2RX | 25U Standard Rack | No | Not applicable |
9307-4RX | 42U Standard Rack | No | Not applicable |
9307-4XX | 42U Standard Rack Extension | No | Not applicable |
9308-4EX | 42U Enterprise Expansion Rack | Yes* | 10 |
9308-4PX | 42U Enterprise Rack | Yes* | 10 |
9360-4PX | 42U 1200mm Deep Dynamic Rack | Yes | 10 |
9360-4EX | 42U 1200mm Deep Dynamic Expansion Rack | Yes | 10 |
9361-4PX | 42U 1200mm Deep Static Rack | Yes | 10 |
9361-4EX | 42U 1200mm Deep Static Expansion Rack | Yes | 10 |
9362-4PX | 47U 1200mm Deep Static Rack | Yes | 11 |
9362-4EX | 47U 1200mm Deep Static Expansion Rack | Yes | 11 |
9363-4CX | PureFlex System 42U Rack | Yes | 10 |
9363-4DX | PureFlex System 42U Expansion Rack | Yes | 10 |
9363-4PX | 42U 1100mm Dynamic Rack | Yes | 10 |
9363-4EX | 42U 1100mm Dynamic Expansion Rack | Yes | 10 |
1410-2RX | Intelligent Cluster 25U Rack Family | No | Not applicable |
1410-4RX | Intelligent Cluster 42U Rack Family | Yes* | 10 |
1410-PRA | Intelligent Cluster 42U 1200mm Deep Rack Family | Yes | 10 |
1410-PRB | Intelligent Cluster 42U 1100mm Enterprise V2 Rack Family | Yes | 10 |
7200-4PX | Smart Analytics 42U Rack Family | Yes* | 10 |
* No support for Full-length I/O Books
For more information, see the list of Lenovo Press Product Guides in the Rack cabinets and options category found at the following address:
http://lenovopress.com/systemx/rack
KVM console options
The following table lists the supported KVM consoles, keyboards, and KVM switches.
Part number | Description |
Consoles | |
17238BX | 1U 18.5" Standard Console (without keyboard) |
Console keyboards | |
00MW310 | Lenovo UltraNav Keyboard USB - US Eng |
46W6713 | Keyboard w/ Int. Pointing Device USB - Arabic 253 RoHS v2 |
46W6714 | Keyboard w/ Int. Pointing Device USB - Belg/UK 120 RoHS v2 |
46W6715 | Keyboard w/ Int. Pointing Device USB - Chinese/US 467 RoHS v2 |
46W6716 | Keyboard w/ Int. Pointing Device USB - Czech 489 RoHS v2 |
46W6717 | Keyboard w/ Int. Pointing Device USB - Danish 159 RoHS v2 |
46W6718 | Keyboard w/ Int. Pointing Device USB - Dutch 143 RoHS v2 |
46W6719 | Keyboard w/ Int. Pointing Device USB - French 189 RoHS v2 |
46W6720 | Keyboard w/ Int. Pointing Device USB - Fr/Canada 445 RoHS v2 |
46W6721 | Keyboard w/ Int. Pointing Device USB - German 129 RoHS v2 |
46W6722 | Keyboard w/ Int. Pointing Device USB - Greek 219 RoHS v2 |
46W6723 | Keyboard w/ Int. Pointing Device USB - Hebrew 212 RoHS v2 |
46W6724 | Keyboard w/ Int. Pointing Device USB - Hungarian 208 RoHS v2 |
46W6725 | Keyboard w/ Int. Pointing Device USB - Italian 141 RoHS v2 |
46W6726 | Keyboard w/ Int. Pointing Device USB - Japanese 194 RoHS v2 |
46W6727 | Keyboard w/ Int. Pointing Device USB - Korean 413 RoHS v2 |
46W6728 | Keyboard w/ Int. Pointing Device USB - LA Span 171 RoHS v2 |
46W6729 | Keyboard w/ Int. Pointing Device USB - Norwegian 155 RoHS v2 |
46W6730 | Keyboard w/ Int. Pointing Device USB - Polish 214 RoHS v2 |
46W6731 | Keyboard w/ Int. Pointing Device USB - Portuguese 163 RoHS v2 |
46W6732 | Keyboard w/ Int. Pointing Device USB - Russian 441 RoHS v2 |
46W6733 | Keyboard w/ Int. Pointing Device USB - Slovak 245 RoHS v2 |
46W6734 | Keyboard w/ Int. Pointing Device USB - Spanish 172 RoHS v2 |
46W6735 | Keyboard w/ Int. Pointing Device USB - Swed/Finn 153 RoHS v2 |
46W6736 | Keyboard w/ Int. Pointing Device USB - Swiss F/G 150 RoHS v2 |
46W6737 | Keyboard w/ Int. Pointing Device USB - Thai 191 RoHS v2 |
46W6738 | Keyboard w/ Int. Pointing Device USB - Turkish 179 RoHS v2 |
46W6739 | Keyboard w/ Int. Pointing Device USB - UK Eng 166 RoHS v2 |
46W6740 | Keyboard w/ Int. Pointing Device USB - US Euro 103P RoHS v2 |
46W6741 | Keyboard w/ Int. Pointing Device USB - Slovenian 234 RoHS v2 |
Console switches | |
1754D2X | Global 4x2x32 Console Manager (GCM32) |
1754D1X | Global 2x2x16 Console Manager (GCM16) |
1754A2X | Local 2x16 Console Manager (LCM16) |
1754A1X | Local 1x8 Console Manager (LCM8) |
Console switch cables | |
43V6147 | Single Cable USB Conversion Option (UCO) |
39M2895 | USB Conversion Option (4 Pack UCO) |
46M5383 | Virtual Media Conversion Option Gen2 (VCO2) |
46M5382 | Serial Conversion Option (SCO) |
For more information, see the list of Product Guides in the KVM Switches and Consoles category:
http://lenovopress.com/servers/options/kvm
Lenovo Financial Services
Why wait to obtain the technology you need now? No payments for 90 days and predictable, low monthly payments make it easy to budget for your Lenovo solution.
- Flexible
Our in-depth knowledge of the products, services and various market segments allows us to offer greater flexibility in structures, documentation and end of lease options.
- 100% Solution Financing
Financing your entire solution including hardware, software, and services, ensures more predictability in your project planning with fixed, manageable payments and low monthly payments.
- Device as a Service (DaaS)
Leverage latest technology to advance your business. Customized solutions aligned to your needs. Flexibility to add equipment to support growth. Protect your technology with Lenovo's Premier Support service.
- 24/7 Asset management
Manage your financed solutions with electronic access to your lease documents, payment histories, invoices and asset information.
- Fair Market Value (FMV) and $1 Purchase Option Leases
Maximize your purchasing power with our lowest cost option. An FMV lease offers lower monthly payments than loans or lease-to-own financing. Think of an FMV lease as a rental. You have the flexibility at the end of the lease term to return the equipment, continue leasing it, or purchase it for the fair market value. In a $1 Out Purchase Option lease, you own the equipment. It is a good option when you are confident you will use the equipment for an extended period beyond the finance term. Both lease types have merits depending on your needs. We can help you determine which option will best meet your technological and budgetary goals.
Ask your Lenovo Financial Services representative about this promotion and how to submit a credit application. For the majority of credit applicants, we have enough information to deliver an instant decision and send a notification within minutes.
Related product families
Product families related to this document are the following:
Trademarks
Lenovo and the Lenovo logo are trademarks or registered trademarks of Lenovo in the United States, other countries, or both. A current list of Lenovo trademarks is available on the Web at https://www.lenovo.com/us/en/legal/copytrade/.
The following terms are trademarks of Lenovo in the United States, other countries, or both:
Lenovo®
ServerProven®
System x®
ThinkSystem®
UltraNav®
X-Architecture®
The following terms are trademarks of other companies:
Intel® and Xeon® are trademarks of Intel Corporation or its subsidiaries.
Linux® is the trademark of Linus Torvalds in the U.S. and other countries.
Microsoft®, Windows Server®, and Windows® are trademarks of Microsoft Corporation in the United States, other countries, or both.
Other company, product, or service names may be trademarks or service marks of others.