Abstract
The ThinkSystem QLogic QL41262 10/25GbE SFP28 2-Port PCIe Ethernet Adapter is based on eighth-generation technology from Cavium and features Universal Remote Direct Memory Access (RDMA) to offer concurrent support for RoCE, RoCE v2, and iWARP. It is suitable for existing 10Gb customers who want to maintain 10Gb network support plus provide the investment protection of supporting 25GbE network speeds.
This product guide provides essential presales information to understand the adapter and its key features, specifications, and compatibility. This guide is intended for technical specialists, sales specialists, sales engineers, IT architects, and other IT professionals who want to learn more about QLogic 25 GbE network adapter and consider its use in IT solutions.
Withdrawn: The adapter described in this product guide is now withdrawn from marketing.
Change History
Changes in the October 31, 2023 update:
- Added the following transceiver - Supported transceivers and cables section:
- ThinkSystem Finisar Dual Rate 10G/25G SR SFP28 Transceiver, 4TC7A88638
Video Introduction
Introduction
The ThinkSystem QLogic QL41262 10/25GbE SFP28 2-Port PCIe Ethernet Adapter is based on eighth-generation technology from Marvell and features Universal Remote Direct Memory Access (RDMA) to offer concurrent support for RoCE, RoCE v2, and iWARP. It is suitable for existing 10Gb customers who want to maintain 10Gb network support plus provide the investment protection of supporting 25GbE network speeds.
The following figure shows the ThinkSystem QLogic QL41262 10/25GbE SFP28 2-Port PCIe Ethernet Adapter.
Figure 1. ThinkSystem QLogic QL41262 10/25GbE SFP28 2-Port PCIe Ethernet Adapter (heatsink removed)
Did you know?
The adapter supports FastLinQ SmartAN auto-negotiation for simplified connectivity with switches without user intervention. SmartAN automates the connection and control of 10Gb and 25Gb connections based on the capabilities of the cables and switches used. This technology ensures that the connection is made with the highest possible speed with highest possible reliability.
Part number information
The ordering information is listed in the following table.
Withdrawn: The adapter described in this product guide is now withdrawn from marketing.
Part number | Feature code | Description |
---|---|---|
4XC7A08228 | B21R | ThinkSystem QLogic QL41262 10/25GbE SFP28 2-Port PCIe Ethernet Adapter |
The adapter, when shipped as a stand-alone option, includes the following items:
- One QLogic adapter
- Full-height (3U) bracket attached with low-profile (2U) bracket included in the box
- Documentation flyer
Supported transceivers and cables
The adapter has an empty SFP28 cage for connectivity. The adapter either supports a connection to a 1Gb, 10 Gb or 25 Gb switch or can share a connection to a 100 Gb switch using a 4:1 breakout cable.
The following table lists the supported transceivers.
Part number | Feature code | Description |
---|---|---|
1Gb Transceivers | ||
00FE333 | A5DL | SFP 1000Base-T (RJ-45) Transceiver |
10Gb Transceivers | ||
00FE331 | B0RJ | 10GBASE-LR SFP+Transceiver |
49Y4216 | 0069 | Brocade 10Gb SFP+ SR Optical Transceiver |
7G17A03130 | AVV1 | Lenovo 10GBaseT SFP+ Transceiver |
49Y4218 | 0064 | QLogic 10Gb SFP+ SR Optical Transceiver |
90Y9412 | A1PM | SFP+ LR Transceiver |
46C3447 | 5053 | SFP+ SR Transceiver |
4TC7A78615 | BNDR | ThinkSystem Accelink 10G SR SFP+ Ethernet transceiver |
25Gb Transceivers | ||
4M27A67041 | BFH2 | Lenovo 25Gb SR SFP28 Ethernet Transceiver |
7G17A03537 | AV1B | Lenovo Dual Rate 10G/25G SR SFP28 Transceiver |
4TC7A88638 | BYBJ | ThinkSystem Finisar Dual Rate 10G/25G SR SFP28 Transceiver |
25Gb transceivers: When installed in this 25Gb Ethernet adapter, 25Gb transceivers are designed to operate at either 25 Gb/s or 10 Gb/s speeds as listed in the description of the transceiver, however the speed also depends on the negotiation with the connected switch. In most configurations, this negotiation is automatic, however in some configurations you may have to manually set the link speed or FEC mode.
The following table lists the supported fiber optic cables and Active Optical Cables.
Part number | Feature code | Description |
---|---|---|
LC-LC OM3 Fiber Optic Cables (these cables require a 10 GbE SFP+ SR or 25 GbE SFP28 SR transceiver) | ||
00MN499 | ASR5 | Lenovo 0.5m LC-LC OM3 MMF Cable |
00MN502 | ASR6 | Lenovo 1m LC-LC OM3 MMF Cable |
00MN505 | ASR7 | Lenovo 3m LC-LC OM3 MMF Cable |
00MN508 | ASR8 | Lenovo 5m LC-LC OM3 MMF Cable |
00MN511 | ASR9 | Lenovo 10m LC-LC OM3 MMF Cable |
00MN514 | ASRA | Lenovo 15m LC-LC OM3 MMF Cable |
00MN517 | ASRB | Lenovo 25m LC-LC OM3 MMF Cable |
00MN520 | ASRC | Lenovo 30m LC-LC OM3 MMF Cable |
SFP+ 10Gb Active Optical Cables | ||
00YL634 | ATYX | Lenovo 1m SFP+ to SFP+ Active Optical Cable |
00YL637 | ATYY | Lenovo 3m SFP+ to SFP+ Active Optical Cable |
00YL640 | ATYZ | Lenovo 5M SFP+ to SFP+ Active Optical Cable |
00YL643 | ATZ0 | Lenovo 7m SFP+ to SFP+ Active Optical Cable |
00YL646 | ATZ1 | Lenovo 15m SFP+ to SFP+ Active Optical Cable |
00YL649 | ATZ2 | Lenovo 20m SFP+ to SFP+ Active Optical Cable |
SFP28 25Gb Active Optical Cables | ||
4X97A94008 | AV1F | Lenovo 3m 25G SFP28 Active Optical Cable |
4X97A94011 | AV1G | Lenovo 5m 25G SFP28 Active Optical Cable |
4X97A94012 | AV1H | Lenovo 10m 25G SFP28 Active Optical Cable |
4X97A94013 | AV1J | Lenovo 15m 25G SFP28 Active Optical Cable |
4X97A94702 | AV1K | Lenovo 20m 25G SFP28 Active Optical Cable |
7Z57A03541 | C10R | Lenovo 3m 25G SFP28 Active Optical Cable |
7Z57A03542 | C10S | Lenovo 5m 25G SFP28 Active Optical Cable |
7Z57A03543 | C10N | Lenovo 10m 25G SFP28 Active Optical Cable |
7Z57A03544 | C10T | Lenovo 15m 25G SFP28 Active Optical Cable |
7Z57A03545 | C1MB | Lenovo 20m 25G SFP28 Active Optical Cable |
QSFP28 100Gb Ethernet Breakout Active Optical Cables | ||
7Z57A03551 | AV1R | Lenovo 3m 100G to 4x25G Breakout Active Optical Cable |
7Z57A03552 | AV1S | Lenovo 5m 100G to 4x25G Breakout Active Optical Cable |
7Z57A03553 | AV1T | Lenovo 10m 100G to 4x25G Breakout Active Optical Cable |
7Z57A03554 | AV1U | Lenovo 15m 100G to 4x25G Breakout Active Optical Cable |
7Z57A03555 | AV1V | Lenovo 20m 100G to 4x25G Breakout Active Optical Cable |
OM4 LC to LC Cables (these cables require a transceiver) | ||
4Z57A10845 | B2P9 | Lenovo 0.5m LC-LC OM4 MMF Cable |
4Z57A10846 | B2PA | Lenovo 1m LC-LC OM4 MMF Cable |
4Z57A10847 | B2PB | Lenovo 3m LC-LC OM4 MMF Cable |
4Z57A10848 | B2PC | Lenovo 5m LC-LC OM4 MMF Cable |
4Z57A10849 | B2PD | Lenovo 10m LC-LC OM4 MMF Cable |
4Z57A10850 | B2PE | Lenovo 15m LC-LC OM4 MMF Cable |
4Z57A10851 | B2PF | Lenovo 25m LC-LC OM4 MMF Cable |
4Z57A10852 | B2PG | Lenovo 30m LC-LC OM4 MMF Cable |
The following table lists the supported direct-attach copper (DAC) cables.
Part number | Feature code | Description |
---|---|---|
SFP+ 10Gb Passive DAC Cables | ||
00D6288 | A3RG | 0.5m Passive DAC SFP+ Cable |
90Y9427 | A1PH | 1m Passive DAC SFP+ Cable |
00AY764 | A51N | 1.5m Passive DAC SFP+ Cable |
00AY765 | A51P | 2m Passive DAC SFP+ Cable |
90Y9430 | A1PJ | 3m Passive DAC SFP+ Cable |
90Y9433 | A1PK | 5m Passive DAC SFP+ Cable |
00D6151 | A3RH | 7m Passive DAC SFP+ Cable |
SFP28 25Gb Passive DAC Cables | ||
7Z57A03557 | AV1W | Lenovo 1m Passive 25G SFP28 DAC Cable |
7Z57A03558 | AV1X | Lenovo 3m Passive 25G SFP28 DAC Cable |
7Z57A03559 | AV1Y | Lenovo 5m Passive 25G SFP28 DAC Cable |
QSFP28 100G-to-4x25G Ethernet Breakout Cables | ||
7Z57A03564 | AV22 | Lenovo 1m 100G QSFP28 to 4x25G SFP28 Breakout DAC Cable |
4Z57A85043 | BS32 | Lenovo 1.5m 100G to 4x25G Breakout SFP28 Breakout DAC Cable |
4Z57A85044 | BS33 | Lenovo 2m 100G to 4x25G Breakout SFP28 Breakout DAC Cable |
7Z57A03565 | AV23 | Lenovo 3m 100G QSFP28 to 4x25G SFP28 Breakout DAC Cable |
7Z57A03566 | AV24 | Lenovo 5m 100G QSFP28 to 4x25G SFP28 Breakout DAC Cable |
Features
The ThinkSystem QLogic QL41262 10/25GbE SFP28 2-Port PCIe Ethernet Adapter has the following key features:
Cost effective single-lane connection
The 25 Gbps Ethernet specification enables network bandwidth to be cost-effectively scaled in support of next-generation server and storage solutions residing in cloud and Web-scale data center environments. 25GbE results in a single-lane connection similar to existing 10GbE technology—but it delivers 2.5 times greater bandwidth. Compared to 40GbE solutions, 25GbE technology provides superior switch port density by requiring just a single lane (versus four lanes with 40GbE), along with lower costs and power requirements. Marvell is a leading innovator driving 25GbE technologies across enterprise and cloud market segments.
High performance Universal RDMA Offload
The Lenovo QL41262 Adapter supports RoCE and iWARP acceleration to deliver low latency, low CPU utilization, and high performance on iSER and Windows Server Message Block (SMB) Direct 3.0 / 3.02. QL41262 25GbE adapters have the unique capability to deliver Universal RDMA that enables RoCE, RoCEv2, and iWARP. Marvell Universal RDMA and emerging low latency I/O bus mechanisms such as Network File System over RDMA (NFSoRDMA) and Non-Volatile Memory Express (NVMe) allow customers to accelerate access to data. Marvell’s cutting-edge offloading technology increases cluster efficiency and scalability to many thousands of nodes.
High density server virtualization
The latest hypervisors and multicore systems use several technologies to increase the scale of virtualization. The Lenovo QL41262 Adapter supports:
- VMware NetQueue
- Windows Hyper-V Virtual Machine Queue (VMQ)
- Linux Multiqueue
- Windows, Linux, and VMware switch-independent NIC partitioning (NPAR)
- Windows Hyper-V, Linux Kernel-based Virtual Machine (KVM), and VMware ESXi SR-IOV
These features provide ultimate flexibility, quality of service (QoS), and optimized host and virtual machine (VM) performance while providing full 25Gbps bandwidth per port. Public and private cloud virtualized server farms can now achieve 2.5 times the VM density for the best price and VM ratio.
Wire-speed network virtualization
Enterprise-class data centers can be scaled using overlay networks to carry VM traffic over a logical tunnel using NVGRE, GRE, VXLAN, and GENEVE. Although overlay networks can resolve virtual Local Area Network (VLAN) limitations, native stateless offloading engines are bypassed, which places a higher load on the system’s CPU. The Lenovo QL41262 Adapter efficiently handles this load with advanced NVGRE, GRE, VXLAN, and GENEVE stateless offload engines that access the overlay protocol headers. This access enables traditional stateless offloads of encapsulated traffic with native-level performance in the network. Additionally, the QL41262 25GbE adapter supports VMware NSX and Open vSwitch (OVS).
Hyperscale Orchestration With OpenStack
The Lenovo QL41262 Adapter supports the OpenStack open source infrastructure for constructing and supervising public, private, and hybrid cloud computing platforms. It provides for both networking and storage services (block, file, and object) for iSER. These platforms allow providers to rapidly and horizontally scale VMs over their entire, diverse, and widely spread network architecture to meet the real-time needs of their customers. Marvell’s integrated, multiprotocol management utility, QConvergeConsole (QCC), provides breakthrough features that allow customers to visualize the OpenStack-orchestrated data center using auto-discovery technology.
Accelerate NFV workloads
In addition to OpenStack, the Lenovo QL41262 Adapter supports Network Function Virtualization (NFV) that allows decoupling of network functions and services from dedicated hardware (such as routers, firewalls, and load balancers) into hosted VMs. NFV enables network administrators to flexibly create network functions and services as they need them, reducing capital expenditure and operating expenses, and enhancing business and network services agility. Marvell 25GbE technology is integrated into the Data Plane Development Kit (DPDK) and can deliver up to 60 million packets per second to host the most demanding NFV workloads.
FCoE and iSCSI storage offloads
The Lenovo QL41262 Adapter supports a hardware offload engine that accelerates FCoE and iSCSI storage protocol processing and enables the server CPUs to focus on applications, thereby improving the server’s overall performance.
Specifications
The adapter has the following technical specifications:
- Marvell FastlinQ 41000 ASIC
- PCIe 3.0 x8 host interface
- Supports Message Signal Interrupt (MSI-X)
- Two SFP28 external connectors supporting a transceiver, direct-attach copper (DAC) cable or active optical cable (AOC).
- Support for PXE boot, iSCSI boot and Wake-on-LAN (WOL)
- Networking Features
- Jumbo frames (up to 9600-Byte)
- 802.3x flow control
- Link Aggregation (IEEE 802.1AX-2008)
- Virtual LANs-802.1q VLAN tagging
- Configurable Flow Acceleration
- Congestion Avoidance
- IEEE 1588 and Time Sync
- Forward Error Correction Clause 74, Clause 91 support over 25 Gbps
- Performance
- Data Plane Development Kit (DPDK) support
- Maximum 60 Million packets per second
- Low latency
- 25Gbps line rate per-port in 25GbE mode
- 10Gbps line rate per-port in 10GbE mode
- Stateless Offload Features
- IP, TCP, and user datagram protocol (UDP) checksum offloads
- TCP segmentation offload (TSO)
- Large send offload (LSO)
- Giant send offload (GSO)
- Large receive offload (LRO) (Linux)
- Receive segment coalescing (RSC) (Windows)
- Receive side scaling (RSS)
- Transmit side scaling (TSS)
- Interrupt coalescing
- Virtualization
- VMware NetQueue support
- Microsoft Hyper-V VMQ support (up to 208 dynamic queues)
- Linux Multiqueue support
- PCI SIG SR-IOV compliant with support for 192 Virtual Functions
- Virtual NIC (vNIC) / Network Partitioning (NPAR) with support for up to 16 physical functions
- Unified Fabric Protocol (UFP) with support for up to 16 physical functions
- VXLAN-aware stateless offloads
- NVGRE-aware stateless offloads
- Geneve-aware stateless offloads
- IP-in-IP-aware stateless offloads
- GRE-aware stateless offloads
- Stateless Transport Tunneling
- Edge Virtual Bridging (EVB)
- Per Virtual Function (VF) statistics
- VF Receive-Side Scaling (RSS)/Transmit-Side Scaling (TSS)
- RDMA over Converged Ethernet (RoCE)
- RoCEv1
- RoCEv2
- iSCSI Extensions for RDMA (iSER)
- Internet wide area RDMA protocol (iWARP)
- Storage over RDMA: iSER, SMB Direct, and NVMe over Fabrics
- NFSoRDMA
- Tunneling Offloads:
- Virtual Extensible LAN (VXLAN)
- Generic Network Virtualization Encapsulation (GENEVE)
- Network Virtualization using Generic Routing Encapsulation (NVGRE)
- Linux Generic Routing Encapsulation (GRE)
- Data Center Bridging (DCB)
- Priority-based flow control (PFC; IEEE 802.1Qbb)
- Enhanced transmission selection (ETS; IEEE 802.1Qaz)
- Quantized Congestion Notification (QCN; IEEE 802.1Qau)
- Data Center Bridging Capability eXchange (DCBX; IEEE 802.1Qaz)
- Storage offloads
- FCoE Hardware Offload
- iSCSI Hardware Offload
- Manageability
- QLogic Control Suite integrated network adapter management utility (CLI) for Linux and Windows
- QConvergeConsole integrated network management utility (GUI) for Linux and Windows
- QConvergeConsole Plug-ins for vSphere (GUI) and ESXCLI plug-in for VMware
- QConvergeConsole PowerKit (Windows PowerShell) cmdlets for Linux and Windows
- UEFI-based device configuration pages
- Native OS management tools for networking
- Full support for Lenovo OneCLI, ASU, XClarity Administrator and firmware updates
- SNIA HBA API v2 and SMI-S APIs
- Power Saving
- ACPI compliant power management
- PCI Express Active State Power Management (ASPM)
- PCI Express eCLKREQ support
- PCI Express unused lane powered down
- Ultra low-power mode
- Power Management (PM) Offload
IEEE standards
The adapter supports these IEEE specifications:
- 802.1AS (Precise Synchronization)
- 802.1ax-2008 (Link Aggregation) (IEEE 802.3ad)
- 802.1q (VLAN)
- 802.1Qaz (DCBX and ETS)
- 802.1Qbb (Priority-based Flow Control)
- 802.3-2015 (10Gb and 25Gb Ethernet flow Control)
- 802.3-2015 Clause 52 (10Gb Ethernet optical)
- 802.3by-2016 (25G Ethernet)
- 1588-2002 PTPv1 (Precision Time Protocol)
- 1588-2008 PTPv2
The adapter supports these additional specifications:
- SFF8431 Annex E (10Gb Direct Attach Copper)
- IPv4 (RFQ 791)
- IPv6 (RFC 2460)
Server support
The following tables list the ThinkSystem servers that are compatible.
Part Number | Description | AMD V3 | 2S Intel V3/V4 | 4S 8S Intel V3 | Multi Node V3/V4 | GPU Rich | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
SR635 V3 (7D9H / 7D9G) |
SR655 V3 (7D9F / 7D9E) |
SR645 V3 (7D9D / 7D9C) |
SR665 V3 (7D9B / 7D9A) |
ST650 V3 (7D7B / 7D7A) |
SR630 V3 (7D72 / 7D73) |
SR650 V3 (7D75 / 7D76) |
SR630 V4 (7DG8 / 7DG9) |
SR850 V3 (7D97 / 7D96) |
SR860 V3 (7D94 / 7D93) |
SR950 V3 (7DC5 / 7DC4) |
SD535 V3 (7DD8 / 7DD1) |
SD530 V3 (7DDA / 7DD3) |
SD550 V3 (7DD9 / 7DD2) |
SD520 V4 (7DFZ / 7DFY) |
SR670 V2 (7Z22 / 7Z23) |
SR675 V3 (7D9Q / 7D9R) |
SR680a V3 (7DHE) |
SR685a V3 (7DHC) |
SR780a V3 (7DJ5) |
||
4XC7A08228 | ThinkSystem QLogic QL41262 10/25GbE SFP28 2-Port PCIe Ethernet Adapter | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
Part Number | Description | 1S V3 | Edge | Super Computing | 1S Intel V2 | 2S Intel V2 | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ST50 V3 (7DF4 / 7DF3) |
ST250 V3 (7DCF / 7DCE) |
SR250 V3 (7DCM / 7DCL) |
SE350 (7Z46 / 7D1X) |
SE350 V2 (7DA9) |
SE360 V2 (7DAM) |
SE450 (7D8T) |
SE455 V3 (7DBY) |
SC750 V4 (7DDJ) |
SD665 V3 (7D9P) |
SD665-N V3 (7DAZ) |
SD650 V3 (7D7M) |
SD650-I V3 (7D7L) |
SD650-N V3 (7D7N) |
ST50 V2 (7D8K / 7D8J) |
ST250 V2 (7D8G / 7D8F) |
SR250 V2 (7D7R / 7D7Q) |
ST650 V2 (7Z75 / 7Z74) |
SR630 V2 (7Z70 / 7Z71) |
SR650 V2 (7Z72 / 7Z73) |
||
4XC7A08228 | ThinkSystem QLogic QL41262 10/25GbE SFP28 2-Port PCIe Ethernet Adapter | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
Part Number | Description | AMD V1 | Dense V2 | 4S V2 | 8S | 4S V1 | 1S Intel V1 | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
SR635 (7Y98 / 7Y99) |
SR655 (7Y00 / 7Z01) |
SR655 Client OS |
SR645 (7D2Y / 7D2X) |
SR665 (7D2W / 7D2V) |
SD630 V2 (7D1K) |
SD650 V2 (7D1M) |
SD650-N V2 (7D1N) |
SN550 V2 (7Z69) |
SR850 V2 (7D31 / 7D32) |
SR860 V2 (7Z59 / 7Z60) |
SR950 (7X11 / 7X12) |
SR850 (7X18 / 7X19) |
SR850P (7D2F / 2D2G) |
SR860 (7X69 / 7X70) |
ST50 (7Y48 / 7Y50) |
ST250 (7Y45 / 7Y46) |
SR150 (7Y54) |
SR250 (7Y52 / 7Y51) |
||
4XC7A08228 | ThinkSystem QLogic QL41262 10/25GbE SFP28 2-Port PCIe Ethernet Adapter | N | N | N | N | N | N | N | N | N | N | N | Y | Y | Y | Y | N | N | Y | Y |
Part Number | Description | 2S Intel V1 | Dense V1 | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ST550 (7X09 / 7X10) |
SR530 (7X07 / 7X08) |
SR550 (7X03 / 7X04) |
SR570 (7Y02 / 7Y03) |
SR590 (7X98 / 7X99) |
SR630 (7X01 / 7X02) |
SR650 (7X05 / 7X06) |
SR670 (7Y36 / 7Y37) |
SD530 (7X21) |
SD650 (7X58) |
SN550 (7X16) |
SN850 (7X15) |
||
4XC7A08228 | ThinkSystem QLogic QL41262 10/25GbE SFP28 2-Port PCIe Ethernet Adapter | Y | N | N | Y | Y | Y | Y | N | Y | N | N | N |
Operating system support
The following table lists the supported operating systems.
Tip: This table is automatically generated based on data from Lenovo ServerProven.
Operating systems | SR150 |
SR250 |
SD530 (Xeon Gen 2) |
SR570 (Xeon Gen 2) |
SR590 (Xeon Gen 2) |
SR630 (Xeon Gen 2) |
SR650 (Xeon Gen 2) |
SR850 (Xeon Gen 2) |
SR850P (Xeon Gen 2) |
SR860 (Xeon Gen 2) |
SR950 (Xeon Gen 2) |
ST550 (Xeon Gen 2) |
---|---|---|---|---|---|---|---|---|---|---|---|---|
Microsoft Windows Server 2012 R2 | N | N | N | N | N | N | N | N | N | N | N | N |
Microsoft Windows Server 2016 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Microsoft Windows Server 2019 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Microsoft Windows Server version 1709 | N | N | N | N | N | N | N | N | N | N | N | N |
Microsoft Windows Server version 1803 | N | N | N | N | N | N | N | N | N | N | N | N |
Red Hat Enterprise Linux 6.10 | N | N | N | N | N | N | N | N | N | N | N | N |
Red Hat Enterprise Linux 6.9 | N | N | N | N | N | N | N | N | N | N | N | N |
Red Hat Enterprise Linux 7.3 | N | N | N | N | N | N | N | N | N | N | N | N |
Red Hat Enterprise Linux 7.4 | N | N | N | N | N | N | N | N | N | N | N | N |
Red Hat Enterprise Linux 7.5 | Y | Y | N | N | N | N | N | N | N | N | N | N |
Red Hat Enterprise Linux 7.6 | N | N | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Red Hat Enterprise Linux 7.7 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Red Hat Enterprise Linux 7.8 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Red Hat Enterprise Linux 7.9 | Y 1 | Y 1 | Y 1 | Y 1 | Y 1 | Y 1 | Y 1 | Y 1 | Y 1 | Y 1 | Y 1 | Y 1 |
Red Hat Enterprise Linux 8.0 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Red Hat Enterprise Linux 8.1 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Red Hat Enterprise Linux 8.10 | N | N | N | N | N | N | N | N | N | N | Y | Y |
Red Hat Enterprise Linux 8.2 | Y 2 | Y 2 | Y 2 | Y 2 | Y 2 | Y 2 | Y 2 | Y 2 | Y | Y 2 | Y 2 | Y 2 |
Red Hat Enterprise Linux 8.3 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Red Hat Enterprise Linux 8.4 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Red Hat Enterprise Linux 8.5 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Red Hat Enterprise Linux 8.6 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Red Hat Enterprise Linux 8.7 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Red Hat Enterprise Linux 8.8 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Red Hat Enterprise Linux 8.9 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
SUSE Linux Enterprise Server 11 SP4 | N | N | N | N | N | N | N | N | N | N | N | N |
SUSE Linux Enterprise Server 11 SP4 with Xen | N | N | N | N | N | N | N | N | N | N | N | N |
SUSE Linux Enterprise Server 12 SP2 | N | N | N | N | N | N | N | N | N | N | N | N |
SUSE Linux Enterprise Server 12 SP2 with Xen | N | N | N | N | N | N | N | N | N | N | N | N |
SUSE Linux Enterprise Server 12 SP3 | Y | Y | N | N | N | N | N | N | Y | N | N | N |
SUSE Linux Enterprise Server 12 SP3 with Xen | Y | Y | N | N | N | N | N | N | Y | N | N | N |
SUSE Linux Enterprise Server 12 SP4 | N | N | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
SUSE Linux Enterprise Server 12 SP4 with Xen | N | N | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
SUSE Linux Enterprise Server 12 SP5 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
SUSE Linux Enterprise Server 12 SP5 with Xen | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
SUSE Linux Enterprise Server 15 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
SUSE Linux Enterprise Server 15 SP1 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
SUSE Linux Enterprise Server 15 SP1 with Xen | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
SUSE Linux Enterprise Server 15 SP2 | Y 3 | Y 3 | Y 3 | Y 3 | Y 3 | Y 3 | Y 3 | Y 3 | Y 3 | Y 3 | Y 3 | Y 3 |
SUSE Linux Enterprise Server 15 SP2 with Xen | Y 3 | Y 3 | Y 3 | Y 3 | Y 3 | Y 3 | Y 3 | Y 3 | Y 3 | Y 3 | Y 3 | Y 3 |
SUSE Linux Enterprise Server 15 SP3 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
SUSE Linux Enterprise Server 15 SP3 with Xen | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
SUSE Linux Enterprise Server 15 SP4 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
SUSE Linux Enterprise Server 15 SP4 with Xen | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
SUSE Linux Enterprise Server 15 with Xen | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
VMware vSphere Hypervisor (ESXi) 6.0 U3 | N | N | N | N | N | N | N | N | N | N | N | N |
VMware vSphere Hypervisor (ESXi) 6.5 | N | N | N | N | N | N | N | N | N | N | N | N |
VMware vSphere Hypervisor (ESXi) 6.5 U1 | N | N | N | N | N | N | N | N | N | N | N | N |
VMware vSphere Hypervisor (ESXi) 6.5 U2 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
VMware vSphere Hypervisor (ESXi) 6.5 U3 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
VMware vSphere Hypervisor (ESXi) 6.7 | Y | Y | N | N | N | N | N | N | N | N | N | N |
VMware vSphere Hypervisor (ESXi) 6.7 U1 | N | N | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
VMware vSphere Hypervisor (ESXi) 6.7 U2 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
VMware vSphere Hypervisor (ESXi) 6.7 U3 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
VMware vSphere Hypervisor (ESXi) 7.0 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y 5 | Y |
VMware vSphere Hypervisor (ESXi) 7.0 U1 | Y 4 | Y 4 | Y 4 | Y 4 | Y 4 | Y 4 | Y 4 | Y 4 | Y 4 | Y 4 | Y 4 | Y 4 |
VMware vSphere Hypervisor (ESXi) 7.0 U2 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
VMware vSphere Hypervisor (ESXi) 7.0 U3 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
1 It needs out of box drivers to support ISCSI and FCOE function
2 It needs out of box driver to support iSCSI and FCoE feature.
3 Need out of box driver to support iSCSI and FCoE function
4 Do not qualify HW iSCSI and FCoE feature, due to Lenovo have no storage target support HW iSCSI and FCoE under ESXi 7.x
5 Need out of box driver to support FCoE and iSCSI feature
Operating systems | SD530 (Xeon Gen 1) |
SR570 (Xeon Gen 1) |
SR590 (Xeon Gen 1) |
SR630 (Xeon Gen 1) |
SR650 (Xeon Gen 1) |
SR850 (Xeon Gen 1) |
SR860 (Xeon Gen 1) |
SR950 (Xeon Gen 1) |
ST550 (Xeon Gen 1) |
x3550 M5 (5463) |
---|---|---|---|---|---|---|---|---|---|---|
Microsoft Windows Server 2012 R2 | Y | Y | Y | Y | Y | Y | Y | Y | Y | N |
Microsoft Windows Server 2016 | Y | Y | Y | Y | Y | Y | Y | Y | Y | N |
Microsoft Windows Server 2019 | Y | Y | Y | Y | Y | Y | Y | Y | Y | N |
Microsoft Windows Server version 1709 | Y | Y | Y | Y | Y | Y | Y | Y | Y | N |
Microsoft Windows Server version 1803 | Y | N | N | Y | Y | Y | Y | Y | N | N |
Red Hat Enterprise Linux 6.10 | Y | Y | Y | Y | Y | Y | Y | Y | Y | N |
Red Hat Enterprise Linux 6.9 | Y | Y | Y | Y | Y | Y | Y | Y | Y | N |
Red Hat Enterprise Linux 7.3 | Y | N | N | Y | Y | Y | N | Y | Y | N |
Red Hat Enterprise Linux 7.4 | Y | Y | Y | Y | Y | Y | Y | Y | Y | N |
Red Hat Enterprise Linux 7.5 | Y | Y | Y | Y | Y | Y | Y | Y | Y | N |
Red Hat Enterprise Linux 7.6 | Y | Y | Y | Y | Y | Y | Y | Y | Y | N |
Red Hat Enterprise Linux 7.7 | Y | Y | Y | Y | Y | Y | Y | Y | Y | N |
Red Hat Enterprise Linux 7.8 | Y | Y | Y | Y | Y | Y | Y | Y | Y | N |
Red Hat Enterprise Linux 7.9 | Y 1 | Y 1 | Y 1 | Y 1 | Y 1 | Y 1 | Y 1 | Y 1 | Y 1 | N |
Red Hat Enterprise Linux 8.0 | Y | Y | Y | Y | Y | Y | Y | Y | Y | N |
Red Hat Enterprise Linux 8.1 | Y | Y | Y | Y | Y | Y | Y | Y | Y | N |
Red Hat Enterprise Linux 8.10 | N | N | N | N | N | N | N | N | N | N |
Red Hat Enterprise Linux 8.2 | Y 2 | Y 2 | Y 2 | Y 2 | Y 2 | Y 2 | Y 2 | Y 2 | Y 2 | N |
Red Hat Enterprise Linux 8.3 | Y | Y | Y | Y | Y | Y | Y | Y | Y | N |
Red Hat Enterprise Linux 8.4 | Y | Y | Y | Y | Y | Y | Y | Y | Y | N |
Red Hat Enterprise Linux 8.5 | Y | Y | Y | Y | Y | Y | Y | Y | Y | N |
Red Hat Enterprise Linux 8.6 | Y | Y | Y | Y | Y | Y | Y | Y | Y | N |
Red Hat Enterprise Linux 8.7 | Y | Y | Y | Y | Y | Y | Y | Y | Y | N |
Red Hat Enterprise Linux 8.8 | Y | Y | Y | Y | Y | Y | Y | Y | Y | N |
Red Hat Enterprise Linux 8.9 | N | N | N | N | N | N | N | N | N | N |
SUSE Linux Enterprise Server 11 SP4 | Y | Y | Y | Y | Y | Y | Y | Y | Y | N |
SUSE Linux Enterprise Server 11 SP4 with Xen | Y | Y | Y | Y | Y | Y | Y | Y | Y | N |
SUSE Linux Enterprise Server 12 SP2 | Y | N | N | Y | Y | Y | N | Y | Y | N |
SUSE Linux Enterprise Server 12 SP2 with Xen | Y | N | N | Y | Y | Y | N | Y | Y | N |
SUSE Linux Enterprise Server 12 SP3 | Y | Y | Y | Y | Y | Y | Y | Y | Y | N |
SUSE Linux Enterprise Server 12 SP3 with Xen | Y | Y | Y | Y | Y | Y | Y | Y | Y | N |
SUSE Linux Enterprise Server 12 SP4 | Y | Y | Y | Y | Y | Y | Y | Y | Y | N |
SUSE Linux Enterprise Server 12 SP4 with Xen | Y | Y | Y | Y | Y | Y | Y | Y | Y | N |
SUSE Linux Enterprise Server 12 SP5 | Y | Y | Y | Y | Y | Y | Y | Y | Y | N |
SUSE Linux Enterprise Server 12 SP5 with Xen | Y | Y | Y | Y | Y | Y | Y | Y | Y | N |
SUSE Linux Enterprise Server 15 | Y | Y | Y | Y | Y | Y | Y | Y | Y | N |
SUSE Linux Enterprise Server 15 SP1 | Y | Y | Y | Y | Y | Y | Y | Y | Y | N |
SUSE Linux Enterprise Server 15 SP1 with Xen | Y | Y | Y | Y | Y | Y | Y | Y | Y | N |
SUSE Linux Enterprise Server 15 SP2 | Y 3 | Y 3 | Y 3 | Y 3 | Y 3 | Y 3 | Y 3 | Y 3 | Y 3 | N |
SUSE Linux Enterprise Server 15 SP2 with Xen | Y 3 | Y 3 | Y 3 | Y 3 | Y 3 | Y 3 | Y 3 | Y 3 | Y 3 | N |
SUSE Linux Enterprise Server 15 SP3 | Y | Y | Y | Y | Y | Y | Y | Y | Y | N |
SUSE Linux Enterprise Server 15 SP3 with Xen | Y | Y | Y | Y | Y | Y | Y | Y | Y | N |
SUSE Linux Enterprise Server 15 SP4 | Y | Y | Y | Y | Y | Y | Y | Y | Y | N |
SUSE Linux Enterprise Server 15 SP4 with Xen | Y | Y | Y | Y | Y | Y | Y | Y | Y | N |
SUSE Linux Enterprise Server 15 with Xen | Y | Y | Y | Y | Y | Y | Y | Y | Y | N |
VMware vSphere Hypervisor (ESXi) 6.0 U3 | Y | Y | Y | Y | Y | Y | Y | Y | Y | N |
VMware vSphere Hypervisor (ESXi) 6.5 | Y | N | N | Y | N | Y | N | Y | Y | Y |
VMware vSphere Hypervisor (ESXi) 6.5 U1 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
VMware vSphere Hypervisor (ESXi) 6.5 U2 | Y | Y 5 | Y | Y | Y 5 | Y | Y | Y | Y | Y |
VMware vSphere Hypervisor (ESXi) 6.5 U3 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
VMware vSphere Hypervisor (ESXi) 6.7 | Y | Y | Y | Y | Y | Y | Y | Y | Y | N |
VMware vSphere Hypervisor (ESXi) 6.7 U1 | Y | Y | Y | Y | Y | Y | Y | Y | Y | N |
VMware vSphere Hypervisor (ESXi) 6.7 U2 | Y | Y | Y | Y | Y | Y | Y | Y | Y | N |
VMware vSphere Hypervisor (ESXi) 6.7 U3 | Y | Y | Y | Y | Y | Y | Y | Y | Y | N |
VMware vSphere Hypervisor (ESXi) 7.0 | Y | Y | Y | Y | Y | Y | Y | Y 6 | Y | N |
VMware vSphere Hypervisor (ESXi) 7.0 U1 | Y 4 | Y 4 | Y 4 | Y 4 | Y 4 | Y 4 | Y 4 | Y 4 | Y 4 | N |
VMware vSphere Hypervisor (ESXi) 7.0 U2 | Y | Y | Y | Y | Y | Y | Y | Y | Y | N |
VMware vSphere Hypervisor (ESXi) 7.0 U3 | Y | Y | Y | Y | Y | Y | Y | Y | Y | N |
1 It needs out of box drivers to support ISCSI and FCOE function
2 It needs out of box driver to support iSCSI and FCoE feature.
3 Need out of box driver to support iSCSI and FCoE function
4 Do not qualify HW iSCSI and FCoE feature, due to Lenovo have no storage target support HW iSCSI and FCoE under ESXi 7.x
5 The WWPN show wrong when created by excute FC-NPIV test under VM6.5.2 os.
6 Need out of box driver to support FCoE and iSCSI feature
Physical specifications
The adatper is a low-profile adapter with the following dimensions:
- Length: 16.7 cm (6.6 in)
- Height: 6.9 cm (2.71 in)
Operating environment
The adapter is supported in the following environment:
- Temperature (operating): 0 to 55 °C (32 to 131 °F)
- Temperature (storage): -40 to 65 °C (-40 to 149 °F)
- Humidity (operating): 10 to 80% non-condensing
- Humidity (storage): 5 to 90% non-condensing
Warranty
One-year limited warranty. When installed in a supported server, the adapter assumes the server’s base warranty and any warranty upgrade.
Agency approvals
The adapter conforms to the following standards:
- UL 60950-1
- CSA C22.2
- TUV EN60950-1
- TUV IEC 60950-1
- CB Certified
- FCC Rules,CFR Title 47, Part 15, Subpart Class A
- Industry Canada, ICES-003: Class A
- EN55032
- EN55024
- EN61000-3-2
- EN61000-3-3
- VCCI: Class A
- AS/NZS: Class A
- KC-RRA Class A
- BSMI CNS 13438
- RoHS compliant
Top-of-rack Ethernet switches
The following table lists the Ethernet LAN switches that are offered by Lenovo.
Part number | Description |
---|---|
1 Gb Ethernet Rack switches | |
7Y810011WW | Lenovo ThinkSystem NE0152T RackSwitch (Rear to Front) |
7Z320O11WW | Lenovo ThinkSystem NE0152TO RackSwitch (Rear to Front, ONIE) |
7159BAX | Lenovo RackSwitch G7028 (Rear to Front) |
7159CAX | Lenovo RackSwitch G7052 (Rear to Front) |
7159G52 | Lenovo RackSwitch G8052 (Rear to Front) |
7165H1X | Juniper EX2300-C PoE Switch |
7165H2X | Juniper EX2300-24p PoE Switch |
1 Gb Ethernet Campus switches | |
7Z340011WW | Lenovo CE0128TB Switch (3-Year Warranty) |
7Z360011WW | Lenovo CE0128TB Switch (Limited Lifetime Warranty) |
7Z340012WW | Lenovo CE0128PB Switch (3-Year Warranty) |
7Z360012WW | Lenovo CE0128PB Switch (Limited Lifetime Warranty) |
7Z350021WW | Lenovo CE0152TB Switch (3-Year Warranty) |
7Z370021WW | Lenovo CE0152TB Switch (Limited Lifetime Warranty) |
7Z350022WW | Lenovo CE0152PB Switch (3-Year Warranty) |
7Z370022WW | Lenovo CE0152PB Switch (Limited Lifetime Warranty) |
10 Gb Ethernet switches | |
7159A1X | Lenovo ThinkSystem NE1032 RackSwitch (Rear to Front) |
7159B1X | Lenovo ThinkSystem NE1032T RackSwitch (Rear to Front) |
7Z330O11WW | Lenovo ThinkSystem NE1064TO RackSwitch (Rear to Front, ONIE) |
7159C1X | Lenovo ThinkSystem NE1072T RackSwitch (Rear to Front) |
7159CRW | Lenovo RackSwitch G8272 (Rear to Front) |
7159GR6 | Lenovo RackSwitch G8296 (Rear to Front) |
7159BR6 | Lenovo RackSwitch G8124E (Rear to Front) |
25 Gb Ethernet switches | |
7159E1X | Lenovo ThinkSystem NE2572 RackSwitch (Rear to Front) |
7Z210O21WW | Lenovo ThinkSystem NE2572O RackSwitch (Rear to Front, ONIE) |
7Z330O21WW | Lenovo ThinkSystem NE2580O RackSwitch (Rear to Front, ONIE) |
100 Gb Ethernet switches | |
7159D1X | Lenovo ThinkSystem NE10032 RackSwitch (Rear to Front) |
7Z210O11WW | Lenovo ThinkSystem NE10032O RackSwitch (Rear to Front, ONIE) |
For more information, see the list of Product Guides in the following switch categories:
- 1 Gb Ethernet switches: http://lenovopress.com/networking/tor/1gb?rt=product-guide
- 10 Gb Ethernet switches: http://lenovopress.com/networking/tor/10gb?rt=product-guide
- 25 Gb Ethernet switches: http://lenovopress.com/networking/tor/25gb?rt=product-guide
- 40 Gb Ethernet switches: http://lenovopress.com/networking/tor/40gb?rt=product-guide
- 100 Gb Ethernet switches: https://lenovopress.com/networking/tor/100Gb?rt=product-guide
Related product families
Product families related to this document are the following:
Trademarks
Lenovo and the Lenovo logo are trademarks or registered trademarks of Lenovo in the United States, other countries, or both. A current list of Lenovo trademarks is available on the Web at https://www.lenovo.com/us/en/legal/copytrade/.
The following terms are trademarks of Lenovo in the United States, other countries, or both:
Lenovo®
ServerProven®
ThinkSystem®
XClarity®
The following terms are trademarks of other companies:
AMD is a trademark of Advanced Micro Devices, Inc.
Intel® and Xeon® are trademarks of Intel Corporation or its subsidiaries.
Linux® is the trademark of Linus Torvalds in the U.S. and other countries.
Microsoft®, Hyper-V®, PowerShell, Windows PowerShell®, Windows Server®, and Windows® are trademarks of Microsoft Corporation in the United States, other countries, or both.
Other company, product, or service names may be trademarks or service marks of others.