Author
Updated
2 Jul 2024Form Number
LP1552PDF size
24 pages, 534 KBAbstract
The ThinkSystem RAID 540 PCIe Gen4 12Gb Adapters are an entry-level 12 Gb SAS/SATA family of internal RAID adapters that offer a cost-effective RAID solution for small to medium business customers. These cacheless adapters support RAID levels 0, 1 and 10, and include an extensive list of RAS and management features.
This product guide provides essential presales information to understand the RAID 540 adapters and their key features, specifications, and compatibility. This guide is intended for technical specialists, sales specialists, sales engineers, IT architects, and other IT professionals who want to learn more about the adapters and consider their use in IT solutions.
Change History
Changes in the July 2, 2024 update:
- Added the following feature codes for 7mm and M.2 NVMe drive support using Tri-Mode - Part number information and Server support sections:
- ThinkSystem Raid 540-8i for 7MM NVMe boot Enablement, BVL4
- ThinkSystem RAID 540-8i for M.2 NVMe Boot Enablement, BVL3
- ThinkSystem Raid 540-8i for M.2/7MM NVMe boot Enablement, BT7P
Introduction
The ThinkSystem RAID 540 PCIe Gen4 12Gb Adapters are an entry-level 12 Gb SAS/SATA family of internal RAID adapters that offer a cost-effective RAID solution for small to medium business customers. These cacheless adapters support RAID levels 0, 1 and 10, and include an extensive list of RAS and management features.
Did you know?
Along with an extensive list of enterprise RAID capabilities, the RAID 540 adapters offer advanced drive diagnostic technologies. In the event of a physical drive failure, the drive is placed in a shielded state and the controller starts drive diagnostics to determine if the drive is indeed failed or can be restored. This saves time, money and server downtime associated with transient drive failures and unnecessary drive replacement.
Part number information
The following table provides the ordering information for the adapters.
Technical specifications
The ThinkSystem RAID 540 PCIe Gen4 12Gb Adapters has the following specifications:
- PCIe 4.0 x8 host interface
- 12 Gbps SAS/SATA RAID controllers, based on the Broadcom MegaRAID 9540 adapter family
- Cacheless (not upgradeable)
- Connectivity for up to 16 internal SAS or SATA drives, depending on the adapters:
- RAID 540-8i: 8 internal drives
- RAID 540-16i: 16 internal drives
- Supports SAS and SATA drives
- Supports NVMe using Tri-Mode (RAID 540-8i only). See the Features section for details and requirements.
- Support for intermixing SAS and SATA HDDs and SSDs. Mixing SAS and SATA drives in the same array is not supported. Mixing of HDDs and SSDs in the same array is not supported.
- Support for intermixing of 24 Gb/s, 12 Gb/s, and 6 Gb/s drives; 24 Gb/s drives operate at 12 Gb/s
- RAID level support: RAID 0, 1, 10
- Support for JBOD (non-RAID) drive state
- Support for up to 63 physical drives with SAS expander (where supported)
- Support for up to 32 virtual drives
- Support for logical drive sizes greater than 2 TB
- Fixed 64 KB stripe size
- Supports 512e, 512n and 4K sector formatted drives
- Supports UNMAP command for SAS SSDs (JBOD and RAID volumes)
- Supports TRIM command for SATA SSDs (JBOD)
- Compliant with Disk Data Format (DDF) configuration on disk (CoD).
- S.M.A.R.T. support.
- Configuration through
- XClarity Provisioning Manager UEFI interface
- XClarity Controller web interface
- XClarity Administrator Configuration Patterns
- StorCLI command-line interface
- LSI Storage Authority (LSA) GUI interface
- UEFI Human Interface Infrastructure (HII)
Note: CacheCade is not supported by these adapters
The following table compares the specifications of the adapters.
To compare these adapters to others in the ThinkSystem portfolio, see the ThinkSystem RAID Adapter and HBA Reference:
https://lenovopress.com/lp1288-thinksystem-raid-adapter-and-hba-reference
Features
The ThinkSystem RAID 540 PCIe Gen4 12Gb Adapters have the following standard features:
- MegaRAID FastPath SSD performance acceleration
MegaRAID FastPath software provides high-performance I/O acceleration for SSD-based virtual drives by using a low latency I/O path to increase the maximum I/O per second (IOPS) capability of the controller. This feature boosts the performance of applications with a highly random data storage access pattern, such as transactional databases.
- Auto-resume on array rebuild or array reconstruction after the loss of system power
Auto-resume uses non-volatile RAM (NVRAM) to save the rebuild progress during a host reboot or power failure to automatically resume from the last checkpoint. Auto-resume ensures that data integrity is maintained throughout the process. The card supports a number of features that can be implemented without rebooting the server. Applications, such as email and web server, benefit from avoiding downtime during the transition.
- Online Capacity Expansion
Online Capacity Expansion (OCE) allows the capacity of a virtual disk to be expanded by adding new physical disks or making use of unused space on existing disks, without requiring a reboot.
- Online RAID Level Migration
Online RAID Level Migration (RLM), which is also known as logical drive migration, can migrate a virtual disk from any RAID level to any other RAID level without requiring a reboot. System availability and application functionality remain unaffected.
- Fast initialization for quick array setup
Fast initialization quickly writes zeros to the first and last sectors of the virtual drive. This feature allows you to immediately start writing data to the virtual drive while the initialization is running in the background.
- Consistency check for background data integrity
Consistency check verifies that all stripes in a virtual disk with a redundant RAID level are consistent. The consistency check mirrors data when an inconsistent stripe is detected for RAID 1 and re-creates the parity from the peer disks for RAID 5 or RAID 6. Consistency checks can be scheduled to take place periodically.
- Extensive online configuration options and advanced monitoring and event notification
Management tools provide convenience for the configuration of logical volumes and alerting when errors have occurred or are about to occur.
- Patrol read for media scanning and repairing
Patrol read is a background sentry service that pro-actively discovers and corrects media defects (bad sectors) that arise normally as a disk drive ages. The service issues a series of verify commands, and if a bad block is discovered, the card's firmware uses RAID algorithms to re-create the missing data and remap the sector to a good sector. The task is interruptible based on controller activity and host operations. The firmware also provides an interface where the patrol read task can be initiated, set up for continuous operation, and terminated from a management application. Patrol read can be activated by a manual command or automatically.
- Global and dedicated hot spare with revertible hot spare support
A hot spare rebuilds data from all virtual disks within the disk group in which it is configured. You can define a physical disk as a hot spare to replace a failed drive. Hot spares can be configured as either global or dedicated. A global hot spare allows any physical drive to be designated as a hot spare. A dedicated hot spare allows the user to assign a hot spare drive to a particular array of the same drive type.
- Drive roaming
Drive roaming occurs when the physical disks are changed to different ports on the same controller. When the drives are placed on different channels, the controller detects the RAID configuration from the configuration data on the drives.
- MegaRAID SafeStore support for self-encrypting drive (SED) services
MegaRAID SafeStore encryption services offer instant secure erase and local key management for self-encrypting drives. This technology represents a step forward in securing data on a disk drive from any unauthorized access or modification resulting from theft, loss, or repurposing of drives. Instant secure erase permanently removes data when repurposing or decommissioning SEDs. SafeStore local key management provides the necessary management and protection of SEDs by using a simple pass phrase, security key identifier, and security key file that can be set and applied to all SEDs that are assigned to a RAID adapter. This feature removes the complexity of managing each SED’s unique encryption key, and it essentially relieves the administrator of most of the daily tasks of securing data.
- XClarity Provisioning Manager for pre-boot array configuration and management
Provisioning Manager is the ThinkSystem UEFI-based application that includes a RAID setup wizard to help you configure drive groups and virtual disks before installing or booting the operating system.
- XClarity Controller web interface for remote storage management
XClarity Controller (XCC) is the systems management processor integrated in all ThinkSystem servers. The XCC web interface allows you to perform storage inventory, create and edit virtual disks, view events, import a new controller configuration, and perform firmware updates on the adapter.
- Hardware Secure Boot
The onboard controller incorporates advanced security by only permitting authenticated firmware to execute on the adapter. The controller’s internal Boot ROM establishes an initial Root of Trust (RoT) and then authenticates and builds a Chain of Trust (CoT) with succeeding firmware images using the RoT, meaning only authorized firmware is executed on the adapter. Lenovo provides the firmware signed by Broadcom, making the use of hardware secure boot transparent to customers, while providing confidence in the security of the solution.
-
Tri-Mode support (RAID 540-8i only)
The RAID 540-8i adapter also supports NVMe through a feature named Tri-Mode support (or Trimode support). This feature enables the use of NVMe U.3 drives at the same time as SAS and SATA drives. NVMe support is enabled on these adapter so that supported servers can support RAID on the 7mm and M.2 operating system boot drives. Cabling of the controller to the backplanes is the same as with SAS/SATA drives, and the NVMe drives are connected via a PCIe x1 link to the controller.
Important notes:
- With the RAID 540-8i adapter, Tri-Mode is only supported to enable RAID on 7mm and M.2 OS boot drives using NVMe drives, and only with the servers listed in the Server support section.
- Only NVMe drives with a U.3 interface are supported. U.2 drives are not supported.
- Tri-Mode is not enabled by default. To enable, consult the RAID 540-8i User Guide in the section "How to activate NVMe support".
Note: MegaRAID CacheCade and MegaRAID Storage Manager are not supported.
Server support
The following tables list the ThinkSystem servers that are compatible.
Operating system support
The RAID 540 adapters support the following operating systems:
- ThinkSystem RAID 540-8i PCIe Gen4 12Gb Adapter, 4Y37A78834
- ThinkSystem RAID 540-16i PCIe Gen4 12Gb Adapter, 4Y37A78835
Tip: These tables are automatically generated based on data from Lenovo ServerProven.
1 For limitation, please refer Support Tip 104278
1 The OS is not supported with EPYC 7003 processors.
2 ISG will not sell/preload this OS, but compatibility and cert only.
1 For limitation, please refer Support Tip 104278
2 The OS is not supported with EPYC 7003 processors.
Warranty
The ThinkSystem RAID 540 PCIe Gen4 12Gb Adapters carry a 1-year limited warranty. When installed in a supported ThinkSystem server, the adapter assumes the server’s base warranty and any warranty upgrades.
Operating environment
The ThinkSystem RAID 540 PCIe Gen4 12Gb Adapters are supported in the following environment:
- Operating:
- Temperature: 10°C to 55°C (50°F to 131°F)
- Relative humidity: 20% to 90% (non-condensing)
- Storage
- Temperature with package: -40°C to 70°C (-40°F to 158°F)
- Relative humidity: 5% to 95% (non-condensing)
Agency approvals
The ThinkSystem RAID 540 PCIe Gen4 12Gb Adapters have the following agency approvals:
- USA (FCC 47 CFR part 15 Subpart B, class B)
- Canada (ICES -003, Class B)
- Taiwan (CNS 13438)
- Japan (VCCI V-3)
- Australia/New Zealand (AS/NZS CISPR 22)
- Korea (RRA no 2013-24 & 25)
- Europe (EN55022/EN55024)
- Safety: EN/IEC/ UL 60950; RoHS; WEEE
Related publications and links
For more information, see the following documents:
- RAID 540-8i User Guide:
https://serveroption.lenovo.com/storage_adapter_options/thinksystem_raid_540-8i_pcie_gen4_12gb_adapter - RAID 540-16i User Guide:
https://serveroption.lenovo.com/storage_adapter_options/thinksystem_raid_540-16i_pcie_gen4_12gb_adapter - Lenovo ThinkSystem product publications:
http://thinksystem.lenovofiles.com/help/index.jsp - ServerProven hardware compatibility:
http://www.lenovo.com/us/en/serverproven - Lenovo RAID Management Tools and Resources:
https://lenovopress.com/lp0579-lenovo-raid-management-tools-and-resources - Lenovo RAID Introduction
https://lenovopress.com/lp0578-lenovo-raid-introduction
Trademarks
Lenovo and the Lenovo logo are trademarks or registered trademarks of Lenovo in the United States, other countries, or both. A current list of Lenovo trademarks is available on the Web at https://www.lenovo.com/us/en/legal/copytrade/.
The following terms are trademarks of Lenovo in the United States, other countries, or both:
Lenovo®
ServerProven®
ThinkSystem®
XClarity®
The following terms are trademarks of other companies:
AMD is a trademark of Advanced Micro Devices, Inc.
Intel® and Xeon® are trademarks of Intel Corporation or its subsidiaries.
Linux® is the trademark of Linus Torvalds in the U.S. and other countries.
Microsoft®, Windows Server®, and Windows® are trademarks of Microsoft Corporation in the United States, other countries, or both.
Other company, product, or service names may be trademarks or service marks of others.
Configure and Buy
Full Change History
Changes in the July 2, 2024 update:
- Added the following feature codes for 7mm and M.2 NVMe drive support using Tri-Mode - Part number information and Server support sections:
- ThinkSystem Raid 540-8i for 7MM NVMe boot Enablement, BVL4
- ThinkSystem RAID 540-8i for M.2 NVMe Boot Enablement, BVL3
- ThinkSystem Raid 540-8i for M.2/7MM NVMe boot Enablement, BT7P
Changes in the November 10, 2023 update:
- The adapter supports the intermixing of 24 Gb/s, 12 Gb/s, and 6 Gb/s drives; 24 Gb/s drives operate at 12 Gb/s - Technical specification section
Changes in the January 13, 2023 update:
- The RAID 540-8i supports NVMe drives using Tri-Mode for 7mm and M.2 OS boot drive support - Features section
- Added feature code BT7P for NVMe support - Server support section
- Added links to the adapter user guides - Related publications and links section
Changes in the February 15, 2022 update:
- New 16-port adapter:
- ThinkSystem RAID 540-16i PCIe Gen4 12Gb Adapter, 4Y37A78835
First published: January 25, 2022
Course Detail
Employees Only Content
The content in this document with a is only visible to employees who are logged in. Logon using your Lenovo ITcode and password via Lenovo single-signon (SSO).
The author of the document has determined that this content is classified as Lenovo Internal and should not be normally be made available to people who are not employees or contractors. This includes partners, customers, and competitors. The reasons may vary and you should reach out to the authors of the document for clarification, if needed. Be cautious about sharing this content with others as it may contain sensitive information.
Any visitor to the Lenovo Press web site who is not logged on will not be able to see this employee-only content. This content is excluded from search engine indexes and will not appear in any search results.
For all users, including logged-in employees, this employee-only content does not appear in the PDF version of this document.
This functionality is cookie based. The web site will normally remember your login state between browser sessions, however, if you clear cookies at the end of a session or work in an Incognito/Private browser window, then you will need to log in each time.
If you have any questions about this feature of the Lenovo Press web, please email David Watts at dwatts@lenovo.com.